Loading...
HomeMy WebLinkAbout6197 EL CAMINO REAL; ; FPC2019-0139; PermitJ1 :iiII:11s]:I Ccity of Carlsbad Print Date: 03/30/2022 Permit No: FPC2019-0139 Job Address: 6197 EL CAMINO REAL, CARLSBAD, CA 92009-1602 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2131000700 Track #: Applied: 06/18/2019 Valuation: $166,505.80 Lot #: Issued: 06/24/2019 Occupancy Group: Project #: Finaled Close Out: 09/25/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASAT BLDG 6.5 - RELOCATE/ADD (36) PENDENT SPRINKLERS FOR NEW SUSPENDED CEILINGS Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov A jITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 18459 ViaSat 136.5 6197 El Camino Real Carlsbad, CA 92009 FPC20I9-0139 6197 EL CAMINO REAL VIASAT BLDG 6.5- RELOCATE/ADD (36) PENDENT SPRINKLERS FOR NEW SUSPENDED CEILINGS 2131000700 6/2412019 FPC20I9-0139 Ii IALSHEET EXISTING FEATURES 18" Sizes: U 21/2' U 3" U 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U G - with groove end OS&Y gate valves U L - less shut-off valves U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U - with cu ft/min meter APPLICATION Designed for installation on potable water fire protection lines to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE ASSE® Listed 1048 (Horizontal and Vertical Flow-Up) A\MNA Compliant C510 (Horizontal & Vertical Flow-Up) UL® Classified (Horizontal) C-UL® Classified (Horizontal) CSA® Certified (Horizontal and Vertical Flow-Up) FM® Approved (Horizontal and Vertical Flow-Up) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow-Up, except 10" vertical) MATERIALS Main valve body Cast Iron ASTM A126 Class B Access covers Cast Iron ASTM A126 Class B Coatings FDA Approved Epoxy finish Internals Stainless Steel, 300 Series Cast Bronze ASTM B 584 Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers DelrinTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U Gate valve tamper switch (OSY-40) B _A - DIMENSIONS & WEIGHTS (do not include pkg.) N DIMENSIONS (approximate) WEIGHT MODEL B E E WITHOUT WITH OS&Y SIZE A WITHOUT C D OS&Y GATE OS&Y F GATE GATE GATE VALVES GATE VALVES VALVES VALVES OPEN VALVES in. lmm in. lmm in. 1mm in. lmm in. I mm in. lmm in. 1mm in. lmm I lbs.I kg Ibs.I kg 21/21 65 371/81 943 22 I 559 4 1102 10 I 254 163/81 416 137/81352 4 1102 101 I 45.9 211 I 95.8 I 80 381/8 968 22 559 1 4 1102 10 I 254 187/81 479 155/81 397 4 1102 101 I 45.9 231 1104.9 IA8 I 200 711/81 1807 48 I 1219 71/21 191 16 I 406 373/41 959 291/4 743 71/21191 847 1384.5 1323 1600.6 10 250 841/8 2137 58 I 1473 1 9 1229 18 I 453/4j 1162 353/81899 9 1229 14101640.1 222811011.5 FLOW CHARACTERISTICS MODEL 950DA 2 1/2 & 3" (STANDARD & METRIC) FLOW RATES (us) 12.6 25.2 37.9 50.5 04 200 400 600 FLOW RATES (GPM) MODEL 950DA 8" & 10" (STANDARD & METRIC) FLOW RATES (us) 63.1 126.2 189.3 0) 39 In 35 800 252.4 104 cc 0. 0 1000 2000 3000 FLOW RATES (GPM) *Rated Flow (Established by approval agencies) 0) 69 WO 35 Uj 4000 TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2' 75 112 149 224 115 173 230 346 198 298 397 595 6' 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 PROTECTIVE ENCLOSURE dyb 0 12 MIN. 30 MAX. SUPPORT DIRECTION OF FLOW MAIN INLET OUTDOOR INSTALLATION VERTICAL INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048, and supplied with full port OS&Y gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM A126 Class B), the seat ring and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a WILKINS Model 950DA. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Rabies, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com Page 1 of 6 \II II(IIS1G® - MICROFAST® QUICK l.IlI[.U'YIV RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfastv Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS c®s cULus Listed: Category VNIV FM Approved: Class Series 2000 WARNING: Cancer and Reproductive Harm- VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 %4V.P65WamingS.ce.gOV PON LPCB Approved: Certificate 096e106 CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) .cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-1W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 ¶ (57 C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 00) = G Form No. F033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 MICROFASTQUICK \J II(lF1Gj RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A '/2" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast' Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. K Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F_033314 19.02.21 Rev 19.1 Page 3of6 ® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal l Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb U Color Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155 °F (68 °C) 100 °F (38 C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. EDO Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) -4111111— Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 19.02.21 Rev 19.1 Page 4 of 6 ® MICROFAST® QUICK \J II(II1G lII[sU'7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com - Approval Chart I (UL) Temperature KEY The Viking Mlcrofast' Quick Response - FS11 Pendent Sprinkler VK302 AIX +- Escutcheon r' apjicabie) Maximum 175 PSI (12 Bar) WWP Base Sprinkler . Thread Size Nominal Overall Listings and Approvals' Part SIN ty e Style K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB ((1 • ________ 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y Dl 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 — -- -- -- — D3 21354 j VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 - I7TI:l! f,ntact Local Viking 06662B VK302 Pendent 1/2" 15 mm FEET80.6 2-1/4 58 A1Z, B1Y, D2, C2X -- -- -- -- 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AiX, B1Y Al AiX, B1Y D1X, dY7 Dl Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 °C), 286 °F (141 °C) Polyester'6, Black Polyes- Viking Micromatic0 Model E-i Recessed Escutcheon B -135 °F (57 °C), 155°F (68 °C), 175°F ter -' Y- Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 °C), and 200 °F (93 °C) 2 - ENT' Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 °F (68 °C), 175 °F (79 °C), and 3 - Chrome Z - Standard surface-mounted escutcheon 200 °F (93 °C) D - 155 °F (68 °C), 175°F (79 °C), 200°F (93 °C), 286°F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-50021. 'MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA -, UL (Also refer to Approval Chart I above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 5 of 6 MICROFAST® QUICK NIIKJW*i RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) -Temperature KEY I The Viking Microfase Quick Response Finish Pendent Sprinkler VK302 A1Xi- Escutcheon (if appffeable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style 1 (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2' 1 15 mm 5.6 80.6 2-1/4 58 AIZ, B1Y, 02X, C2 '(.)t(iE - Product Bel Limited Availability Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 1 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 1 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A - 135°F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F X - Standard surface-mounted escutcheon or the (93 °C), 286 °F (141 °C) Approved Finishes Viking Micromatic8 Model E-1 Recessed B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and I - Brass, Chrome, White Polyester", Escutcheon 200 °F (93 °C) and Black Polyester4 Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 with the Viking Micromatic® Model E-1 or E-2 °F (141 °C) Recessed Escutcheon 0 - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above) FM Approval Requirements: The Viking Microfast®1 Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 6 of 6 MICROFAST® QUICK N4 I KI W4j :RESPONSE PENDENT RINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT A - . ®%? •1T'' ______ L. . AIN 57mm _____ (45 mm) RP Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-1I8"... (54 mm) T (45 mm) Max. -.ø (54 mm) .4 (51 mm) Max. 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) ull Moose Tube'sO Schedule B SCHEDULE 10 PIPE SPECIFICATIONS 10 and Schedule 40 are FM Approved and UL Listed (for U.S. NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE and Canada), even though these SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE products do not require separate approvals and listings. Bull 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 Mooselube® made the decision 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 to have them approved and listed. 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3:053 61 Our Schedule 10 and Schedule 40 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 have a pressure rating of 300 PSI 2-1/2 2.875 2.635 4.92 3.53 lbs/ft - 5.893 30 and have been through the same 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 rigorous testing as our other fine 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 pipe products. Schedule 10 can be supplied roll grooved or plain end. SCHEDULE 40 PIPE SPECIFICATIONS Bull Moose Tube's Schedule 10 and Schedule 40 pipes are hot NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE dipped galvanized to meet ASTM SIZE (IN) (IN) (IN) CRR** WEIGHTIFT WEIGHT SIZE Al 23 standards. All products are stencilled to meet FM & UL 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 specifications. 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 100 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ -Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED <> APPROVED i]ONFM NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com C~3 Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road -8 Chesterfield, MO Gerald, MO KentWA Casa Grand AZ Dallas, TX MasurI4 OH 63017 Dull Moose Tube's® Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE® EDDYTHREAD 40® I.) is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDYTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 c®us LISTED APPROVED no ONFS NFPA Ip,l"I., *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masury, OH BUI.L. MOOSE TUBE co,srgy 63017 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED <> APPROVED i]4 £n,.dcan pin NFPA S ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED - PER Ft FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 *Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masurt OH .uuMacsuaEcar.ev 63017 Dull Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® I.) is a specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD Il® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR* PER Ft WI. SIZE an opportunity for downsizing 11/4 1.660 1.530 1.98 - - 1.222 2.019 61 and further cost savings. 1.900 1.728 3.44 1.844 - 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED <9> APPROVED no ONFSA NFPA 7 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ DaIlas1X Masurt OH us Cc"V11PAJ." 63017 Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I) a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED INT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 * Pressfit is a Registered Trademark of Victaulic Company of America ** Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED APPROVED (] &'!4 NFPA 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande,AZ Dallas, X Masurt OH BULL MOOSE TUBE COMSEY 63017 c®us LISTED <9> APPROVED C;] 4.FSA NFPA IUo. NIPS (IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 1.315 1.660 1.900 2.375 1.201 1.546 1.786 2.261 ULTRA EDDY EmptyWeightJb/fti] 0.868 1.107 1.274 1.604 aterAUedWeight(lb/ft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 - 1 D. (in 1.660 1.900 2.375 2.875 3.500 4.500 LD.(in) 1.530 1.728 2.203 2.705 3.334 4.310 Weight (Ib/ft)' EDDY FLOW Empty 1.222 1.844 2.330 2.809 3.361 4.968 'Water-Filled Weight(lb/lt) 2019. 2.860 3.982 5.299 7.144 11.290 L I CRR 198 344 278 166 100 100 AD.. (in)__ 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I.D.-On) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE 'Empty Weight (ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 1 - water-Filled Weight CIA),1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R.1527 991 776 627 492 354 250 0.D. (in) 1.315 1.660 1.900 2.375 l.D.011) 1.137 1.482 1.712 2.177 EDDYLITE Empty Weight (lb/ft) 1.260 1.617 11.967 2.617 iWater-Alied Weight (lb/f, 1.700 2.364 2.965 4.230 C.R.R. 0.13 0.08 0.12 0.16 1 - OD (in) 1.295 1.650 1.900 2.375 LD.(in) 1.083 1.418 1.645 2.123 EDDYTHREAD Empty)eight (lb/ft) 1.461 2.070 2.547 3.308 400 ,Water -Filled Weight (lb/fl) 1.860 2.754 3.468 4.842 C.R.R. _j 1.00 1.00 1.00 1.00 0.D. (in)_____ 1.315 1.660 1.900 2.375 2.875 3.500 4.500 ID (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE _Empty Weight(tb/ft. 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 Water-filled Weight (Ib/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16316 C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 - For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com C~s tD, Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande. AZ DalIasjX Masury. OH BULL MODSEIIJBE caiv,.jv 63017 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY® 0.868 91 1,659 1,896 1.975 SCHEDULE 10 1.410 91 2,695 3,079 3,208 1 EDDYLITE® 1.260 91 2,408 2,752 2,867 EDDYTHREAD4O® 1.461 70 2,148 2,454 2,557 SCHEDULE 40 1.680 70 2,470 2,822 2,940 ULTRA EDDY® 1.107 61 1,418 1,621 1,688 EDDY FLOW® 1.222 61 1,565 1,789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2760 11/4 EDDYLITE® 1.617 61 2,071 2,367 2,466 IYTHREAD 0 .2.070 51 2217 2,534 2,639 L. J SCHEDUE4O 2.270 51 2,431 2,778 2,894 ULTRA EDDY® 1274 61 1,632 1,865 1,943 EDDY FLOW® 1.844 61 2,362 2,700 2,812 SCHEDULE1O 2.090 61 2,677 3,060 3,187 1-1/2 EDDYLITE® 1.967 61 2,520 2,880 3,000 EDDYTHREAD 40 2.547 44 2,353 2,690 2,802 SCHEDU!J 2.720 44 2,513 2,872 2,992 ULTRA EDDY® 1.604 37 1,246 1,424 1,484 EDDY FLOW® 2.330 37 1 810 2 069 - 2 155 2 SCHEDULE1O 2640 37 2051 - 2,344 2,442 EDDYUTE® 2.617 37 2,033 2,324 2,421 L EDDYTHREAD 400 3.308 30 2,084 2,382 2,481 SCHEDULE40 3.660 30 2,306 2,635 2,745 EDDY FLOW® 2.809 1,770 2,022 2,107 2-1/2 SCHEDULE-10--i 3.530 30 2,224 2,542 2,648 -SCHEDULE 40. 5.800 3,654 4,176 4,350 EDDY FLOW® 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4.340 19 1,732 1,979 2,062 SCHEDULE40 7.580 3,624 3,456 3,601 EDDY FLOW® 4.968 1,982 2,265 2,360 4 SCHEDULE 10 5.620 19 2,242 2,563 2,670 _JSCHEDULE 401 10.800 4,309 4,925 5,130 6 SCHEDULE10. 9.289 10 1,951 2,229 2,322 8 SCHEDULE 10 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande, AZ. C®US LISTED <9> APPROVED (;] /4 NFPA 10 Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft7 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 1/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 1 809 648 531 455 381 40 40 40 40 37 34 1 31 29 28 26 1 25 24 4 1 1544 1 1235 1 1012 1 867 726 1 40 40 40 40 40 1 37 1 34 1 32 30 1 29 1 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft7 25 ft. 30 ft. 35 ft. 40 ft. 0.25 1 0.50 10.75 1.00 1.25 1.50 1.75 2.00 12.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 1 1/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 1 1/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL. MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED <19> APPROVED no £ NFPX Q For Additional Information Contact (800) 325-4467 - www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road - Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ DallasjX Masur0H ui.i. ,vloDsrucaN,wAray 63017 11 Mechanical-I® STYLES 920 AND 920N Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder° locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/345OkPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. STYLES 920 AND 920N STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade 'T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date__________________________________ www.victaulic.com vlcTAuuc IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. C 2017 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_N \4'tauUic 11.02_i DIMENSIONS I ~- "40-0-MI 11-al !j 10 GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x W'/50 x 15 mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. App Dimensions Weight 2 ½ (a) a 920N 500 1.50 2.00 2.53 1.61 j 5.35 275 3.1 X 50 15 3450 38.1 51 _64 4 - 41 136 70 1.5 500 3/4 (a) a 920N 1.50 1.97 2.53 I 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - j 41 136 70 1.5 - 1(a) a 920N500 1.50 1.85 2.53 I 161 5.35 2.75 3.0 25 3450 38.1 - 1.75 47 64 - - 2.05 2.75 41 136 t -- 70 1.4 - - - 14 (a) to 920N 500 300 1.61 5.35 300 3.5 32 32 I 3450 44.5 52 70 I 7"T 76 - 41 136 76 17 .1.5 1 ½ (a) to 920N 500 1.75 2.03 3.12 1.61 5.35 3.25 3.6 3.2 40 920N [ 3450 I 500 445 1.50 1 52 70 _[ 2.21 2.74 79 41 1.82 136 83 1.7 3.0 1.5 21/1 ½ (a) §a >< 564 2.75 65 15 1 3450 38.1 56 j, 70 - 46 143 70 1.4 - 500 34(a) §0 920N 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 _i -t 2.06 2.74 - 46 1.82t 143 5.64 70 2.75 1.4 1(0) §a 920N 500 1.50 2.9 25 11/4 t là) a 3450 500 38.1 1.75 52 70 2.30 T 3.00 1 - 1 3.25 46 T 1.82 143 6.29 70 3.00 1.4 3.5 - 3.2 920N 58 I 76 I 32 3450 44.5 83 -.+---±--..---- 46 160 76 1.7 1.5 -- 2.00 3.25 11/5 t (a) a 920N 500 2.28 3.00 3.25 1.82 I 6.26 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 3.18 1.7 1.6 761 ½ (a) 920N 300 1.50 2.22 2.75 2.25 6,46 3.9 15 2065 38.1 56 70 - j, 57 164 81 1.8 - 300 '/4(a) 920N 1.50 2.19 I 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 I 70 - 57 +---.- 164 81 1.8 - 1(a) 25 920N 300 2065 1.50 38.1 2.07 2.75 53 70 I -1 2.25 57 6.46 164 3.18 81 3.8 1.7 - 11/4 (a) a 920N 500 1.75 2.30 3.00 I 3.31 1 1.92 1 6.29 3.00 3.5 3.2 32 1½ (a) a 40 920N 920N 3450 44.5 58 76 2.28 3.00 58 76 2.52 3.05 I 84 3.31 84 49 1.92 49 2.28 4. 160 6.29 160 i 6.15 3.25 83 2.75 4. 1.6 3.5 1.6 3.4 1.5 3.3 1.5 500 3450 500 2.00 50.8 1.50 3 112 (a) a 80 15 'A (a) u 20 920N 3450 500 3450 38.1 1.50 38.1 64 78 2.49 t 3.05 63 + 78 - - 58 2.28 58 156 6,15 156 1 70 2,75 70 1.6 3.4 1.6 - 1(a) 920N 500 1.50 2.38 3.06 - 2.28 6.15 2.75 3.3 - 25 3450 38.1 61 78 58 156 70 1.6 500 1 V. (a) to 920N 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 1h 3450 44.5 2.00 --f -t 65 83 2.78 3.50 90 3.56 --+ I 58 2.28 I 156 6.15 76 - 3.25 1.8 1.8 3.8 500 1 (a) to 40 (b) °t I .a I 156I83i 4.1 2.50 2 (a) a 920N 500 2.75 3.50 3.56 I 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 2.50 70 89 3.00 90 3.75 58 2.44 I 172 6.72 I 99 3.88 2.3 2.1 3.8 31/2 2 - 3450 500 90 50 63.5 76 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 761 mm threaded outlet, specify 21e BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com vICTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vICTAULIC COMPANY. ALL RIGHTS RESERVED. 1LO2_2 '\/ -C tauIicr REV_N DIMENSIONS FEMALE THREADED OUTLET to Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/345OkPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½'/50 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size Styl I Max Approx. TABLE CONTINUED FROM PAGE 2 4 x 1/2 (a) a 500 1.50 920W 3.03 3.56 2.69 7.01 2.75 I 3.7 100 15 3450 38.1 1 77 90 - - 68 178 -t -t -t - 70 I 1.8 - 1/4 (a) a 20 920W 500 1 1.50 1 3450 1 38.1 1 3.00 76 3.56 90 - 2.69 68 7.01 178 2.75 , 70 3.7 1.8 - 1(a) a 25 920N 500 150 3450 381 2.88 73 3.56 90 - 2.69 68 7.01 178 2.75 70 3.6 1.8 - , , 11/4 (a) to JL 920W 500 1.75 3450 445 3.08 78 3.78 _96. 4.00 19 2.69 8i17.+26 7.01 3.00 4.0 J! 3.6 !. 11/2 (a) to 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 920W 40 (b) 3450 50.8 83 102 102 . 68 178 83 2.0 1.9 2 (a) to 500 2.50 N 3.25 2.69 I 7.01 3.88 5.0 4.6 4.00 4.00 50 920 3450 63.5 i 83 102 102 68 I 178 i 99 2.3 2.1 21h (a) t 920 500 2.75 i 2.88 4.00 4.00 2.69 7.34 i 4,63 5.8 5.0 65 1 3450 699 73 102 102 ~t . !. 6.1mm 500 2.75 920 3450 69.9 2.88 73 ' 4.00 102 2/29 68 7.34 186 4.63 118 - 6.4 2.9 3(a) 1 ._. 920 500 3.50 3.31 ...... 4.50 4.12 .. ...................__. 2.69 7.73 f. 5.12 8,4 6.4 80 43450 88.9 84 114 ms 68 o 130 .28 2.9 108 )< .0 1 144 (a)0 920W 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 32 3450 44.5 78 96 - 67 194 78 2.3 - 11/2 (a(a 920W 500 i 2.00 ' 3.28 4.00 2.63 7,64 3.25 5.0 40 345050/2 83 102 - 67 194 83 23 2 (a) 920W T 500 2,50 j 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 67 194102 19 76 mm .1 920 500 2.75 j2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 ( 3.6 ' 1 3.5 920 500 3.50 3.31 3(a) 4.50 4.50 2.63 7.63 I 4,88 6.8 6.5 80 I 3450 88.9 920 500 2.00 84 4.03 114 114 4.75 1 67 3.16 194 9.70 I 124 3.69 3,1 7.4 I 3.0 7.6 5 1½ (a) t 4.75 125 40 3450 50.8 j 102 121 !! I 9.. I 1. 2 i ± I 4.75 2(a) t " 500-T 250 4.00 920 4.75 3.16 9.70 I 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 I iii 3.7 I 3.6 920 500 2.75 3.63 4.75 4.75 21/2 (a) t 3.16 9.70 4.63 8.3 7.9 65 76.1 mm 3450 69.9 a 920 500 1 2.75 92 3.75 121 121 4.75 80 3.16 246 9,70 118 4,63 3.8 3.6 8.0 J3450 1 69.9 95 .ii121 80 246 118 3.6 3(a) t 500 3.50 13.81 920 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 500 2.50 920N 97 3.75 127 4.50 118 80 3,17 -'t-l---- 246 8.00 135 3.88 3.8 -. 8.0 4.0 2 133.0 x 50 j 3450 63.5 95 114 - 81 , 203 99 3.6 - 500 3.50 i 3,81 5.00 3.00 9.46 5.31 8.0 80 920 ( 3450 1 88.9 1 97 127 - 76 240 I 135 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com V1CTAULiC IS A REGISTERED TRADEMARK OF vICTAULiC COMPANY. C 2017 vicrAuLic COMPANY. ALL RIGHTS RESERVED. X. A-C-ts -U1 i or REV_N 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N I']II1[.1i1 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½/50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 1 P4. IV Styl e Pressure@ Dimensions am 80 ____ I . III TABLE CONTINUED FROM PAGE 3 1397 x 1½ t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 _50.8 96 !!± t 4.50 - 84 209 83 3.2 3.30 2 t 920¼ 500 2.50 3.75 8.23 3.88 9.0 50 j 920¼ I 3450 63.5 95 1.75 4.43 445 112 114 5.13 130 - 5.13 130 84 3.79 96 209 j, 9.15 232 4 99 3.25 4.1 5.1 - 4.8 6 11/, (a) 50 X 500 3450 11/2 (a) tu 920¼ 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 .. 83 2.4 , 2.3 2(a) fa 920¼ 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 [ 3450 63.5 111 130 130 96 232 99 2.7 2.5 21/5 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 .---. 3450 69.9 110 i° _. 267 .. . JI !1_. 3.4 8.4 3.8 761 mm a 920 I 500 3450 ' 2.75 4.15 69.9 105 5.21 132 3.69 94 10.51 267 4.63 118 5.50 9.9 8.4 3(a) t 920 500 3.50 4.31 5.13 3.69 10.51 5.31 80 3450 88.9 110 140 130 94 267 4, 135 4.5 3.8 4 (a) to 100 920 920N 500 500 4.50 3.81 11434,97 2.00 4.41 5,75 146 5.13 5.38 137 3.69 .94 3.63 10.51 j 9.40 267J24 6.25 3.25 10.1 7.8 10,1 146 . 159.0 x 1½ (a) 40 - 3450 508j 112 130 500 2(a) 76.1 mm 920¼ 63.5 3450 250 ' 438 , 2.75 4,38 69.9 111 513 , - 363 , 940 . 9.40 239 388 , i 4,63 118 80 . 9.5 4.3 - 9.5 4.3 920 500 3450,j, 5.50 140 5.13 130 3.63 92 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 j 140 130 92 239 , 135 3.7 6.4 500 4.50 4.45 5.38 3.63 9.40 6.12 10,0 108.0 mm 920 345Ø4,fl43 flfl - 137 92 239155 -4.5 2 500 4.50 3.81 5.75 3.63 4 9,40 6.25 18.0 lao 3450 114.3 96.80 146 - 92 I 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21h" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services Approved for use in China by Tianjin Approvals Company. www.victauluc.Com vIcTAuuc IS A REGISTERED TRADEMARK OF VICTAuLIc COMPANY. 02017 vICTAuuc COMPANY. ALL RIGHTS RESERVED. X0 A-s-tau I i ice 11.02_4 REV.N DIMENSIONS E L=.- 01, IM Re-'-N I GROOVED OUTLET FV- F-- Y I r -r- z 0- n IR in FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N -ii'i lPressure@~: Style Weight, I[AL] -a l WI 21 TABLE CONTINUED FROM PAGE 4 65 1 x 1 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 - t 96 , 237 70 3.6 - 11/4 0 32 920N 500 3450 1.75 44.5 4.43 113 5.13 1 130 I - 3.79 96 9.34 1 3.25 237 83 8.4 3.8 - 1½ (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 f - 9.34 3.25 8.4 5.4 40 2 (a)t 3450 500 (, 50.8 2.50 - 112 4.38 130 I 5.13 130 5.13 96 3.79 237 83 9.34 3.88 . I 8.5 I 50 920N 3450 1 63.5 U! ! 6.0 1 76. mm 920 500 2.75 4.01 5.13 5.21 1 3.63 10.51 4,63 8.6 7.6 + 3450 69.9 110 j 130 132 92 _267 _j 118 f 3.9 3.4 3(a) t 0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 e& 110 140 130 1 92 1 267 135 46 3.8 - 10.5 4 (a) tn 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 8.4 100 920 3450 500 114.3 97 5.44 146 6.19 137 6.25 t 92 4.81 267 159 12.42 T 4.50 4.8 11.6 3.8 11.6 8 2(a) f 200 3450 69.9 138 157 159 122 316 114 5.3 5.3 21/2 (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 1 122 316 114 5.3 5.3 76.1 mm 13 920 500 2.75 5.25 6.25 4.81 . 12.42 4.56 11.6 ____ - 3450 69.9 1 133 - - .,.- 159 1 + 122 - 316 116 + - 5.3 3(a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4 (a) fa 920 500 4.50 4.81 6.75 6.38 4.81 'i" 12,42 6.25 15.3 12.5 100 3450 114.3 122 171 162 i 122 316 1 159 I 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 41 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify °BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com V1CTAULIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2017 V1CTAULIC COMPANY. ALL RIGHTS RESERVED. Ac-t a -U1 ii e REV_N 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°FI+16°C are shown in the table below. Formulas for C5 1K Values: (1 AP =Q2 Where: p = Where: V C 2 Q= Flow (GPM) Q= Flow (m3/hr) ( i AP = Pressure Drop (psi) Q = C x C = Flow Coefficient AP = Pressure Drop (Bar) [•j ) —p Q = K x /A Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size S chedule 40 Carbon Steel Pipe ½ OUTLETIer4 4TI (!ti1iI!a I I iiai 0.840 - 2 - Values 11 15 21.3 SA 4 1050 20 26.7 13.7 1 1.315 8 - 2] 25 33.7 j .8 1 1A 1 1.660 5 ½ 6 48 32 42.7 42.9 41.1 1½ 1.900 53 1 53 40 98.3 11 454 2 2.375 9 10 /1 112 104 50 60.3 96 89.1 2½ 2.875 20 12½ 119 150 65 . 73.0 102 128.5 76.1 mm 3.000 16 161 - - 3.500 14 15½ 249 237 80 88.9 213.4 - 203.1 -- -. . - 00 20 22 421 401 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. 1 FireLock" Innovative Groove System (IGS) outlet www.victaulic.com taulia VICTAULIC IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV...N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Rated Approval Working Pressures Agency — psi/kPa 21/2-6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-16 8.3 2.875 - 4.500 All 01 2755 300 2755 300 2755 j 300 1999 290 [ 1599 232 2496 362 21/2 -4 65-100 73.0-114.3 All SF 1 2065 300 2065 300 2065 300 1999 290 t 1599 232 2496 362 21/2-4 2.875 - 4.500 65-100 6.625 - 2065 - 300 2065 - 300 2065 250 1999 290 1 1599_ 232 2496 362 6 150 168.3 6.625 34 I 10 - . . 300 300 300 290 232 2496 6 150 34 30,40 2065 2065 2065 1999 1599 2496 362 8 8.625 21/2 10 40 400 145 200 21 8.625 34 1 , 10 300 1 - 250 . - .L 145 8 200 219] 8.625 34 - 30,40 - + --- -- 300 1 300 - 1000 - 145 - - - - 8 200 219.1 2065 - 2065 - 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 87100 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-I and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-I unit is a full port ball valve which can be mounted on 47100mm, 57125mm, 67150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com ',4'ctaUIiC vICTAuLIC IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. © 2017 vICrAuLIc COMPANY. ALL RIGHTS RESERVED. REVN 11.027 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the I-lOU Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV N UPDATED 12/2017 VIcTAuLIc IS A REGISTERED TRADEMARK OF VIcTAuLIc COMPANY. 02017 vIcTAuuc COMPANY. ALL RIGHTS RESERVED. X, As -ts -U1 ii e 11.02_L STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'A through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR l lei II]I System No. Submitted By Spec Sect Para___________ Location - Date Approved Date www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. G 2009 vICTAUuC COMPANY. ALL RIGHTS RESERVED. REV_G XA_Cta_U1_id 10.52_i FireLock® Outlet-T STYLE 922 III MIMLSIM -U, ..v H4pUlI .. IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 3275 Diameter H Ole Dimensions h inches/millimeters i Appr x. 13Ao 30.2 1.30 33.0 1.83 46.5 1.10 27.9 3.87 98.3 256 65.0 1.0 0.45 3/4 20 13/16 30.2 1.28 32.5 1.83 46.5 1.10 27.9 3.87 98.3 2.56 65.0 4 1.1 0.50 1 25 13/16 30.2 1 30.2 1.52 38.6 1.42 36.1 2.18 55.4 1.95 49.5 1.10 - 279 1.22 31.0 3.87 983 4.08 103.6 2.56 65.0 2.56 65.0 , 1.2 0.54 1.2 0.54 1½ x ½ 40 15 1/4 20 1 No 30.2 1.40 35.6 1.95 1 49.5 1.22 31.0 4.08 103.6 2.56 65.0 1.2 0.54 1 25 1 /i6 30.2 1 /io 39 1.64 41.7 1.66 2.30 58.4 2.19 1 1.22 31.0 1.46 4.08 103.6 4.60 116.8 2.56 65.0 2.56 ..... 1.3 0.59 1.3 0.59 2 x ½ 50 15 3/4 20 1 25 No 30.2 1 i/6 30.2 13/16 30.2 1.64 41.7 1.88 47.8 1.91 48.5 .............37.1 2.19 2.54 64.5 2.44 62:0 1.46 1.46 37.1 1.71 - 43.4 55.6 _65.D, 4.60 4.60 116.8 5.40 137.2 2.56 2.56 65 2.56 65.0 1.4 0.64 1.5 0.68 1.6 - 0.73 2½ x ½ 65 15 3 4 20 1/6 30.2 1.89 48.0 2.44 62.0 1 1.71 43.4 5.40 1372 2.56 65.0 1.6 L 0.73 1 25 1 °Ao 30.2 2.13 54.1 2.79 70.9 I 1.71 43.4 5.40 137.2 I 2.56 65.0 1.6 0.73 76.1 mm X___ t 3/~ 20 1 30.2 1.89 48.0 2.44 62.0 1,71 43.4 5.50 139.7 2.56 65.0 1.6 0.73 - 25 13,i6 30.2 2.13 54.1 2.79 70.9 1.71 43.4 5.50 139.7 2.56 65.0 1.7 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF vICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED, 10.522 4tauiicr REV_C IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com - - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ictaul.c REVG 10.52_3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV UPDATED 12/2009 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings SMITH COOPER," INTERNATIONAL Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to :300 WSP Ductile iron castns oi orm to ASTM A53 c @us, LISTED Fitting dimensions conform to ASME B 16.3 Bushings and plugs conform to ASME B 16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME BI.20..1 Indeç.ende:it la bi verification that fittings meet applicable chemical & pysica1 properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Ten-zeralure Degrees F Workirg Fressure, Nonshock piG 3flU Class Threaded Filin. -2: to 100 530 1 5 530 .200 430 250 430 :300 .350 - 440 420 .400 430 450 380 ,&00 360- 550 343 600' 323 - -303 Fig. 35E3-90° Elbow COUS <~~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35E 3004 35E 3006 1.13 100 200 0.2 0.3 1.31 70 140 1 1-1/4 35E 3010 35E 3012 1.50 40 80 0.5 1.75 25 50 0.8 1-1/2 2 35E3014 1.94 18 36 1.1 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Size in Part Number A in B in Packing Weight lb Inner I Master 3/4 x 1/2 - lx 1/2 35RE3006004 1.20 1.22 80 160 0.3 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 1-1/4 x1 35RE3012006 35RE3012010 - 1.45 1.63 35 70 0.6 1.58 1.67 30 60 0.7 1-1/2x1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 - 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 2x1/2 35RE3014012 1.82 - 1.88 18 36 1.0 351RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 2x1-1/4 35RE3020010 35RE3020012 1.73 2.02 16 32 1.2 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 2.16 2.51 10 6 20 12 1.5 2.2 2-1/2x1-1/2 35RE3024014 2-1/2 x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in N umber I Part u A In Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 1 35F 3006 0.98 80 160 80 0.3 35F 3010 1.13 40 0.5 1-1/4 _'O 3012 - 1.29 - 25 50 0.7 1-1/2 2 35F3014 1.44 20 40 1.0 35F 3020 35F 3024 1.69 10 20 1.6 2-1/2 1.95 4 8 2.7 Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 160 0.3 3/4 351 3006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 3513020 2.25 6 12 2.4 2-1/2 3513024 1 2.70 1 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com C®US <E> APPROVED Fig. 35RT3 - Reducing Tee LISTED Size in Part Number A in B in C in Packg_ Weight lb Inner Master 3/4x1/2 1x1/2 35RT3006004 120 1.20 1.22 1.36 60 30 120 0.4 0.6 35RT3010004 1.26 1.26 60 1x1/2x1 1 x3/4 35R13010004010 1.50 1.38 1.36 1.38 1.50 1.45 30 25 60 50 0.6 0.6 35RT3010006 1x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35R13010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 1-1/4 x3/4 1-i/4x3/4x1-1/4 35R13012004012 35RT3012006 1.75 1.53 1.75 25 50 0.9 0.9 1.45 1.45 1.62 15 30 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 25 30 50 1.0 0.7 1-1/4x1x1/2 35R13012010004 1.34 1.26 1.53 1-1/4 x1x3/4 35R13012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x lxi 35RT3012010010 1.58 1.50 i.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35R13014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x 1-1/4 1-1/2x3/4x1-i/2 1-112x1 35RT3014006012 1.94 1.66 1.88 20 40 1.1 35RT3014006014 35RT3014010 1.94 1.75 1.94 18 36 1.2 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 11/2x1x3/4 35RT3014010006 150 144 175 16 32 09 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 ..1!2x1x1-1/4 35R13014010012 1.82 1.67 1.88 12 24 1.2 1-1/2xlx1-1/2 35R13014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-114 35RT3014012 1.82 1.82 1.88 12 24 1.4 i-1/2x1-1/4x1/2 35R13014012004 1.41 1.34 1.66 16 32 0.9 i-1/2x1-1/4 x3/4 1-1/2x1-1/4 x1 35R13014012006 1.52 1.45 1.75 16 32 1.0 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35R13014012012 1.82 1.75 1.88 14 - 14 28 1.3 1-1/2x1-1/4x1-1/2 35R13014012014 1.94 1.88 1.94 28 1.4 2x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2x 1 x2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-i/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 - 2 x 1-1/2 x 3/4 35RT302001 4006 1.60 1 52 197 10 20 1.4 2x1-1/2x1 35R13020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35R13020014014 2.02 1.94 2.16 8 16 FTB II rTW lUll! Fig. 358T3 - Bull Head Tee Size in Part Number T in B in C in Packing Weight lb Inner Master 3/4x1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35813010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 1.2 1-1/4x1x1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1-1/4x1-1/2 35B13012014 1.88 1.88 1.82 15 30 1.3 i-1/4 x2 35B13012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4 x2 35813014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 c®uS APPROVM Fig. 35CP3 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 35CP3004 35CP3006 35CP3010 138 200 400 0.1 1.63 100 200 120 0.2 0.4 1.75 60 1-1/4 1-1/2 2 2-1/2 35CP3012 35CP3014 35CP3020 35CP3024 2.00 35 70 0.5 2.19 25 50 0.7 2.62 15 30 1.2 3.00 9 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1 x 3/4 35RC3010004 35RC3010006 1.69 80 160 0.3 1.69 60 120 - 0.4 1-1/4 x 3/4 2xl(nothex)l 35RC3012006 2.06 40 80 0.6 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 - 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2x1-1/4 2 x 1-1/2 35H83020012 35H93020014 1.38 40 80 0.6 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 1.12 600 350 1200 700 0.07 0.1 3/4 - 353P3006_-: 1 35SP3010 1.25 1.37 200 100 400 200 0.1 0.3 1-1/4 35SP3012 1-1/2 35SP3014 1.44 80 160 0.4 - 2 35SP3020 1.50 45 90 - 0.6 I Eli! Fig. 35RC3 - Hex Reducing Coupling Fig. 35U 3- Union with Brass Seat Size in Part Number _______________ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 - 1-1/2 35U 3012 - 35U3014 2.50 15 30 1.2 2.62 10 20 -- 12 1.7 2 35U 3020 3.12 6 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com A A Size in Part Number A in Packing Weight lb Inner Master 1 1-1/4 35X 3010 1.50 20 40 24 0.9 1.4 35X3012 1.75 12 1-1/2 - 2 - 35X 3014 3 -5: 7 3020 1.94 8 16 1.8 2.25 6 -12 -l--2.8 Fig. 35R13 - Reducing Cross I Size I in I I I Part I A I in I B i in I Packing I Weight I I lb I I Inner I Master I 1-1/4x1 35RX3012010 1.67 I 1.58 I 15 I_30 I 1.2 I I1-1/2x1 35RX3014010 l 1.80 I 1.65 I_12 I_24 I 1.4 I 2 x 1 35RX3020010 I 2.02 I 1.73 I_8 I_16 12.01 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35C3004 3503006 0.87 300 600 0.1 0.97 200 400 0.1 1 3503010 1.16 110 220 0.2 1-1/4 1-1/2 35C 3012 1.28 70 140 0.4 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 358C3 - Ream Clamp I C@US <e> APPROVED A A Fig. 3513- Cross LISTED ra':Ar4 Size in Part Number A in Packing I Weight I lb Inner I Master 3/8 35B03003 0.75 100 200 0.3 1/2 35B03004 0.75 80 1 160 1 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 8904456 • www.smithcooper.com 114 INSTALLATION STEPS INTO WOOD & STEEL:jALLATION STEPS I(! oILt INTO WOOD & STEEL Insert the appropriate nut driver into a 3/8"or 1/2" portable drill Insert the SAMMYS& into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4', 3/8 112"orrnetric all thread rod, belt stock. (The 1/2"requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maxirnumpullout in purtin steel. Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot tbs. for maximum pullout in purlin steel. INSTALLATION STEPS -c!AjjJ INTO CONCRETE: Using an SDS 250 carbide tip bit era HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 81139 10) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pro-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1/2"screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS -J •jjj INTO CONCRETE: Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member toe depth of 2" with a hammerl rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pm-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8'or metric all thread rod or bolt stock Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. - _____ iiilM1m1t1ul'liilI1lH$ SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sate Installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMYSO FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. (T-----) a ñdoodemonsiretiona ww.ifwbulldex.com a. #14 Black Nut Driver Part # 8113910 I #14 SW Red Nut Driver Part # 8114910 1/4' 8002957 GST 100 114x1 1/4" 8003957 GST 200 1/4 x 2' 1/4' 8004957 GST 300 1/4 x 3" 3/8' 8007957 GST10 1/4x? €' 3/6' 8008957 GST 20 1/4 x 2 3/8 8068925 GST 20-SS 114x2 3/8 8009925 GST 25-380 3/8 x 21/2 3/8 8010957 GST 30 1/4x3 3/8' 8069925 GST 30-SS 1/4 x 3 3/8" 8011925 GST40 1/4 x4" 1/2" 8013925 GST2 1/4x2 - 1/2 8014925 WT 2.5-380 3/8x21/2 1/2' 8015925 GST3 1/4x3" 210 (7/16OSB) 25 125 670 (3/4Ply) 1760 25 125, 2060 (Fir) 25 125 210 (7116" OSB) 300 25 125 1760 (Fir) 850 1475 25 125 1760 (Fir) 850 25 125 2113 (Fir) 1500 25 125 2060 (Fir) (r) - 1500 1475 25 125 2060 (Fir) 25 125 2180 ((ir) 25 125 1760 (Fir) 25 125 - - - 5 -125 2275 (Fir) 25 125 ARk IV &Owmk~ Wo V-41 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each lime. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not less than 2" nominal width 4111111111111 (14/21 up to 3-112" pipe; not tess than 3'(2-11T) nominal With 4'& 5" pipe Floor Joist IL Minimum 2-112" from bottom for 11 branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. "No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. I%Watch a vid& cmana5atk,n7 wwwMwbulldex.comJ u 1/4" 8019957 SWG200 1I4x2" 1725 (Fir) 25 125 I - 802957 SWG1O 1/4x 2 (F 300 - 25125 a 318" 8021957 SWG20 114x2" 1725 (Fir) 1050 25 125 3/8" - 8073925 SW - G2O-SS I/4x2" 1725 (Fir) 850 25 125 4 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 #14SWRed - - 3! Q3 ! SWG 30 .,i 1~84 Nut Driver Part #8114910 "May require pre-drilling; consult joist manufacturer wmim ,omITm PA. NAXA.NMEW "Eliminates distortion of threaded rod. "Accommodates up to 3W x 12 pitch roof. Allows 17° deflection from vertical. "Saves time from traditional methods. "Reduces installation costs. 'Mad e in the U.S.A. IIW#U9t•1Ur' Y- - #14 Black - /?.e 3/8" 8139957 Stt-GST2O 1/4x2" 1257 (Fir) 1050 1475 25 125 • SH-GT30 Nut Driver Part#8113910 1/4x3 1720 (Ar) 1500 1475 1903 Dim. Lumber 1500 3/8" 8269957 SH-GST/CSI 20 5/16s1-3/4" 1406 @ 45°off vertical 25 125 Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GSTICST2.0 5/16x1-3/4 1406@45°offvertical 25 125 Dim. Lumber "May require pre-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Part #8273910 SAMMYS FOR STEEL Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. p Made in the U.S.A. Watch a video demonstration of 11 wwwitwbulldex.com #14 Black Nut Driver Part # 8113910 1/4" 8024957 DSTRIOO 1/4-20x1"TEKS3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1 -T/F-80250— 051100 1/4-14 xl TEKS 3 446 (209a) 036 20 ga 3/16 1/4" 8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 8027957 051200 1/4 14x2 TEKS3 446 (20 .936"-20 ga 3/16 25 125 - 1/4" 8030957 TEK500 12-24x1-1/2"TEKS5 3125 (3/16") .188-3/16 1/2" 25 125 [3/8 8038957 DSTF 1 1/420x 1TEKS3 0(20ga) 1500 147503620ga3/16 25 SJ 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-112" TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 3/8_8039957 DSTR5 5/16-18x 11/4 TEKS3 2200 (20 ga) 1500 U7503620ga 3/16 25 5] 3/8" 8040957 DST 10 1/4-14x1"TEKS3 446 (20 .036'-20 ga 3/16" 25 125 [ 3/8" 8077925 DSTIO-SS 1I414x1TEKS3 .036"-209a 3/16" 25 125 1 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 .03&-20 ga 3/16" 25 125 318" 8078925 DST 15-SS 3/8" 8042957 DST 20 1/4-14x1-112"TEKS3 446 (20 ga.) - 1/4-14 x 2"TEKS 3 446 (20 ga.) 970 (16 ga.) .036"-20 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 1- #14 SW Red Nut Driver Pan /I 8114910 3/8" 804;57 0S125 1/4-14x2-1/2"TEKS3 446 (20 - .036"-20 ga 3/16" 251251 3/8" 8044957 DST 30 1/4-14x3"TEKS3 446 (20 .036"-20 ga 3/16" 25 125 _DST 516 5/16 18x11/4 TEKS3 1500 Th00 U75 5fl8 3/1625 i] > 3/8"8046957 TEK 50 12-24 a 1-1/2" TEKS 5 3125 (3/16") 1500 1475 .250"-1/4" 1/2"25125 [ 1)2" 8031925 DST 2.0 1/4-14x2TEKS3 446 (20 .188"-3/16" 1/4" 25 125 1/2" 8033925DSTRI.0 1/4-20x1*TEKS3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 L 1)28034925 DSTR516 5618x11MTEKS322200ga) 036 20 ga 3/16 25 5J 1/2" 8035925 DST 5.16 5/16-18 a 1-1/4" TEKS 3 1500 (3116") .125"-1/8" 3/16 25 125 :03925 TEKSO 1224x 1112TEKS5 3125 (3116) 18831161/2 25 i1 "Includes retaining nut __________ SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation () '' each time. When the face of the driver comes into contact with the material you are installing Into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ei MMAMME YS1 jJJJIL!I4LII 0 lid 01011PI ffw~rl tffM Made with Tekse self-drilling fasteners - no pre-drilling required. no Installs into steel range from 20 gauge - 1/2° thicknesses. d - A standard screwgun with a depth sensitive nosepiece should be used to red install Teks. For optimal fastener performance, the screwgun should be a ' 9 minimum of 6 amps and have an RPM range of 0-2500. "Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. 14/alch a video den onstmtion at Made in the U.S.A. www.ffiwbulldox.com Approvals Rod Size Part Model Number Screw Descriptions Ultimate UL Test FM Test Min Max Pullout (lbs) Load (lbs) Load (lbs) Thickness Thickness Box Case Cty Cty I 0[F1LI - 1/4" 8047957 SWD 100 1/4-14 Xl" TEKS 3 1477 (16 ga.) .060"-I6 ga 3/16" 25 125 1/4 8049957 SWORIOG 1114-20 x V TEKS3 1900 (209a) 036 20ga 3/16 25 125 3/8' 8050957 SWD 10 1/4-14 xl TEKS 3 1477 (16 ga.) .060"-16 ga 3/16' 25 125 3/8 8080925 SWD 10-SS 1/414 x I TEKS 3 1477 (16 ga) '060"-1 6 ga - 3/16 25 1253 3/8" 8051957 SWD 15 1/4-14 x 1-112" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16 25 125 L - 3/88052957 911620 1/414x2 TEKS3 1477 (l6ga) 060 l6ga 3/16 25 125 -S-WD 8053957 516 5/16.18 x 1.1/4" TEKS 3 2480 (20 ga.) .036"-20 ga 3/16 25 125 [:QL- 3/88055957 SWDRI 1/420x1TEKS3 1900 (209a) 1500 1475 036 20ga -3-11-6"-2-5 ---1257 #14 SW Red . "S' 3/8" 8054957 SWDR 1.1/2 * 12.24 x 1.1/2" TEKS 5 -23-7-5-(3/16") 1500 1475 .188"-3116" 1/2° 25 125 Nut Driver 3/88056957 SWDR 516 5/1618x-1 1-/4 TEKS 3 2480(20ga) 1500 1475 036 20 ga 3)16 25713 Part #8114910 3/8" 8057957 SWT15 12-24 x 1-1/2"TEKS 5 2375(3/16") .188-3/16" 1/2° 25 125 'Includes retaining nut "Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. "Allows 17° deflection from vertical. "Made in the U.S.A. I #14 Black Nut Driver - Part # 8113910 318 8137957 SH-DSTR 1° 1/4-20 Xl" 3220(3/161 TEKS 3 hutch a idea do,nooal,otion at www.ftwbuildex.com 1500 1475 .035" 3/16" 25 125 i #14 SH Orange Nut Driver Part #8273910 2368(1/2" steel Vertical) 3/8" 8268957 SH-TEK 50 12-24x1-3/4" 1306 (45 off Vertical) TEKS 5 2281 (3116- HSS) 1585 (3/16" HSS 45 off Vertical) 2368(1/2° steel Vertical) 1/2" 8270957 SR-TEK 50 12-24 x 1.314" 1306(45° off Vertical) TEKS 5 2281 (3116- NSS) 1585(3/16° NSS 45° off Vertical) Does not comply with R011S requirements /!ncludes retaining nut 1500(Vertical) 4" 3/16° 1/2° 25 125 850(45" off Vertical) 2-1/2" The Sammy X-Press expands to provide Less jobsite material needed, direct vertical attachment in: light gauge steel deck or purlin No retaining nut required. (22 ga. - 118"). Provides design flexibility. Installs in seconds with Sammy X-Press ta Tool, saving time & installation costs. Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. t'atch a video demonstrational . www.11wbuildex.com It 125" 25 125 Puin S A Il/ill/i Y X-P RE SS@ Installs into Metal Deck, Purlin, or Tubular Steel 1/4" 8181922 XP 200 Sammy 1146(22ga)185 (Luminaire) .125" 25 125 Metal Deck X-Press 200 250 (Luminaire) OW 850 (2W Pipe) .02 940 (2" Pipe) 029" I <> 3/8" 8150922 XP 20 Sammy1146 (22 gal 185 (Luminaire) .027" 1475 (4 Pipe) :104" .125" 25 125 Metal Deck X-Press 20 250 (Luminaire) .056" 283 (Conduit & Cable) .029" 1500(4" Pipe) .060" Samm. 3/8" 8153922 XP 35 1783 (16 ga)250 .125" 25 125 Pudin X-Press 35 (Luminaire) 1475 (4" Pipe) 416 (Conduit & Cable) .059" i-r ----------- - I Pm-Pour Structural Concrete@ 3000 psi 3/8" 8150922 XP 20 x 'mmy ro 1146(22 ga) 850(24Pipe) 25 125 (Pre-Pour) i L Post-Pour Range It LWC 35 PCF (lbs/It5) Metal Deck I (Post-Pour) Pre-Pour Structural Concrete @3000 psi Post-Pour Range It LWCS 35 PCF (tha/ It") V. (SWXP) The SidewinderX-Press expands to provide • Less jobsite material needed. horizontal attachment in: -16 ga - 3/16" steel - pudin, tubular steel. No retaining nut required. "Installs in seconds with Sammy X-Press It° Tool, • Provides design flexibility. saving time & installation costs. "Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; le. metal roof deck, tubular steel, or vapor barrier fabric. With a video demonstration at www.iiwbuiidex.com for [ce1e or jr~ant coot pitCh85 MMYSI The Swivel X-Press allows you to hang plumb in extreme roof pitches: - 89° in z-pudin - 45° in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press Ite Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor baffler fabric, Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Watcv a v demonsfrarvat www.itwbulldex.com 750(2" Pipe) 42. 3/8' Swivel 8294922 SXP 20 1061 (22 ga Ve rt)xo 170 Vertical (Luminaire) 029" 635 (2* Pipe) 25 125 Metal Deck .029" .125" 283 Vertical (Conduit & Cable) - - 233 @45° (Conduit & Cable) 1250(3-1/2" Pipe) Swivel 4<j> 3/8" 8295922 SXP 35 1675 (16 ga Vert) 250 Vertical (Luminaire) 059" 25 125 Purtin X:33 s (2" Pipe) .029" .125" Came 500 Vertical (Conduit & 333 @89° (Conduit & Cable) 1/2" 8272957 SXP 2.0 Swivel 1061 (22 ga Van) 25 125 Metal Deck .027" .125" XsO Swivel 1675 (16 ga Vert) 1/2" 8271957 SXP 3.5 X-Press 3.5 1558(89° Off Vert) .060" .125" 25 125 Purlin The Sammy X-Press expands to provide direct vertical attachment in: metal deck (22-16 gauge) z-pudin (18-16 gauge) Made in the U.S.A. 34 www.lMrbuildex.comj Part Number Model Description .' 8194910 UXPIT° Universal X-Press It Tool 1 8152910 XPDB 25/84" Drill Bit 1 *Tool Includes: Sleeve, Bit Receiver, lieu Wrench, and 25/64" Drill Bit. APPROVALS 8007957 GST 10 3/8' Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8' Horizontal CPVC 1-1/2' 300 1-112' 8008957 GST2O 3/8' Vertical 2-1/2" 850 1-1/2" 4' 1475 1-1/2' 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2' 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4' 1475 1-1/2" 8009925 GST25-380 3/8" Vertical 4' 1500 1-1/2" 8022925 SWG2S-380 3/8' Horizontal 3-1/2'-4'* 1500 1-1/2" 8021957 SWG2O 3/8" Horizontal 2-1/2"-3"° 1050 1-1/2' 8073925 SWG2O-SS 3/8" Horizontal 2-1/2" 850 1-1/2' 8269957 SH-GST/CST 20 3/8' 45" Angle off Vert/cal 2-1/2' 850 1-1/2' 8269957 SH-GST/CST2O 3/8" 45" Angle off Vertical 4" 1500 1-1/2' 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" rfliiTj1j lThtrcfYi11 I 8038957 DSTR 1 3/8" Vertical 4' 1500 .035' 4' 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4° 1500 .037" 4' 1475 .105" 8045957 DST 516 3/8' Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEKSO 3/8" Vertical 4" 1500 .250" 4' 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4° 1475 .060" 8054957 SWDR 1-112 3/8' Horizontal 4" 1500 .037" 4' 1475 .060" 8137957 SH-DSTR1 3/8" 17" Angle off Vertical 4' 1500 .035' 4" 1475 .105' 8268957 SH-TEK 50 3/9' Vertical 2-1/2' 850 70" Angle off Vertical 4' 1500 8150922 XP 20 3/8" Vertical 2-1/2' 850 .027' , 1475 .105, 8153922 XP 35 3/8' Vertical 4' 1500 .060" 8294922 SXP 20 3/8" Vertical or up to 450 2' 750 .027" 2" 635 .029' 8295922 SXP 35 3/8" Vertical orupto89° 3-1/2" 1250 .060' 2" 635 .029" 8293957 SWXP35 3/8' Horizontal 3-1/2" 1250 .060" I SAMMYS FOR CONCRETE PIPE HANGER 8059957 CST 20 3/8' Vertical 4' 1475 3000 8061957 SWC 20 3/8" Horizontal 4' 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2' 850 Pre-Pour Structural @ 3000p5i 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range U LWC S 35 PCF (lbs/It3) 8150922 XP 20 3/8" Vertical 185 .027" 250 .035' 8153922 XP 35 3/8" Vertical 185 .027" 250 .035' 8181922 XP 200 114' Vertical 185 .027' 250 .035' 8294922 SXP 20 3/8' Vertical 170 .027' 45° 80 .027' 8295922 SXP 35 3/8' Vertical 250 .060" 90" 80 .060' 8293957 SWXP 35 Rod 3/8 Mount UL SteelPart Load Horizontal UL Min. 80 .060" Model Number Size .]zIc'H It•ltrtIt tIl:tl[e1VIi Direction Rating (lbs) .. Thickness Listed Application 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8' Vertical 283 . .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060 Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8' Horizontal 500 .060' Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8' Onto Vertical Rod UL Listed 4S16 - Cable Hanger Cat. No. C12000 Plenum Rated, Complies WI NEC Standards Cheet Steel Gauges Gauge No. - 22 ga. 20 ga. IS ga. 16 ga 14 ga, 12 ga. 1/8" 3116' 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105' .125' .188' .250' SWG 25-380 Maximum pipe size in composite wood ic/nt allowed by UL is 3-1/2 UI compliance with NEC Standards. SWG 25-380 Maximum pipe size In wood tmber or joist allowed by UL is 4' UL and FM texts were performed in compliance with NFPA 13 Standards. WG 20 Ma smurn pipe sex composite wood joist allowed by UlJ2' Fastening requirement: 5 times weight of water-tiled schedule 40 pipe pies 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-puriin applications in May 1997 using (.037) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030°) or 22 gauge steel metal deck. SammysO Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite JoistiTruss Truss manufacturers vary installation recommendations for composite joist UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: rModel Root'1T1iiTni Hole riSize GST 2O .182" 1/8" GST 25-380 .280" 7132" SWG 20 .182" 1/8 SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling NFPA!NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings! FM Approvals UL and FM reports are available at www.itwbuildex.com ALIOUSTEOASOOIaU&9DCASUI,iflwaz ,uo,mtoAsN.owLaun fi21 Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products Contact information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/411 Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, olease refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California OSHPD Approved c Seismic Restraints System ©(1S LISTED Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1Ae 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13Ae 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25- Surge Restrainer C @ us LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Dimensions -Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved C@ vs LISTED Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number H Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100- All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY. 1375 SAMPSON AVE.. CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.137.0330 a. CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 200-21I2 to 200-8 Fig. 200 Fig. 200S Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONA ØTOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B3170NF9 Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317014FC) Fig. 200S "Trimline" Adjustable Band Hanger with Non-Captured Nut C® US LISTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in '.. hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) 0/4" (20mm) thru 8' (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of knurl nut. Order By Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Fig. 200F Part No. 00_1J2 Pipe in. 1 1(1' Size (MM) Rod Size /8°-16 A in. (MM) 3i/(79.4 5/66.7)11 in. B (MM) Approx. Itis. Wt. 00 (kg) ' (5.0 200-/4 3/4' (20) /8-16 31/8' (79.4) 21/2 (63.5) 11 (5.0) 200-1 1' (25) /8'-16 3/8 (85.7) 2/8 (66.7) 12 (5.5) 200-1/4 11/4° (32) /81 -16 33/4 (94.0) 2/8' (73.0) 13 (5.9) 200_11/2 11/2' (40) I8"-16 3I8' (98.4) 2/8" (73.0) 14 (6.4) 200-2 2" (50) /8-16 41/2 (114.3) 3° (76.3) 15 (6.9) 200-2I2 21/2" (65) /8"-16 5I8' (142.9) 41/8' (104.7) 27 (12.3) 200-3 3" (75) /8-16 5/8" (149.1) 4' (101.6) 29 (13.3) 200-3/2 31/2° (90) /8'-16 7/8" (187.3) 51/4 (133.3) 34 (15.6) 200-4 4° (100) 1 3/8"-16 7 /8" (187.3) 51, (127.0) 35 (16.0) 200-5 (125) /2-13 91/8 (231.8) 6/4 (158.7) 66 (30.2) 200-6 (150) 1/2"..13 101/8' (257.2) 6/4' (171.4) 73 (33.4) 200-8 8' (200) 1/2 _13 131/8 (333.4) 8/4" (222.2) 136 1 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown In parentheses are in millimeters unless otherwise specified. COO ER B-Line Fig. 200-21/2 to 200-8 Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 0/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. '.. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) H -1 to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications %W-H-1 71 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Part No. 200M8-1/2 Pipe in. 1/2 Size (Mrn) (15) Rod Size M8 A in. (MM) 31/8 (79.4) in. 2/8 B (MM) (66.7) Approx. lbs. 11 Wt./100 (kg) (5.0) 200M10-1/2 1/2" (15) M10 31 /8 (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200M10-3/4 3/4° (20) M10 31/8" (79.4) 2/2" (63,5) 11 (5.0) 200M8-1 1" (25) M8 3 /8" (85.7) 2/8" (66.7) 12 (5.5) 200Mb-1 1" (25) M10 3 /8" (85.7) 2/8" (66.7) 12 (5.5) 2001148-11/4 11/4' (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200Mi0-11/4 11/4" (32) M10 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" 1 (40) M10 3/8" (98.4) 2/8" (73.0) 14 (6.4) 20011018-2 (50) M8 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 (50) M10 41/2" (114.3) (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5/" (142.9) 4/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 3/2" (90) M10 7I8" (187.3) 51/4' (133.3) 34 (15.6) 200M-4 4" 1 (100) M10 7 /8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6' (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in Inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. leol COO ER B-Line Fig. 200K - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thw 4" (100mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /"-16 or 1/2"..13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapee supports as well as the lower hanging unit must be able to hold the maximum loads intended. C® US fj uSTEo IIIIjj III Part No. 200H-2-3/8 Pipe in. 2" Size (MM) (50) Rod Size /8"-16 in. 4/16" A (MM) (115.9) in. B (nim) Approx. lbs. 48 (21.8) Wt./100 (kg) 200H-2-1/2 2" (50) 1/2"..13 423/32" (119.8) 33/8" (85.7) 45 (20.4) 200H-2112-318 21/2" (65) /8"-16 5/16" (134.9) 3 3/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 53/4" (146.0) 327/32" (97.6) 63 1 (28.6) 200H-3-1/2 3° (75) 1/2"13 5 /8" (148.1) 331/32" (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8" (174.6) 4 /16" (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/2"_13 7/32" 1 (178.6) 419/32" (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line I1 VIL F P P I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. [jjtjefr - pips • I j Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ'' System Compatible Program* Certified to NSF/ANS/Std 61-G FBCV;'. SYSTEM COMPATiSL *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX+1 800 344-3775 © 2012 Fire Protection Products, Inc. FPPP, LubeRtO are registered trademarks of fire Protection Products, Inc. FGG/BM/CZ, Blaze-Master, RowGuard Golds and Co,zanA are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. 0 F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FB(/;-. SYSTEM COMPA11BLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaste, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL +1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been 'made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5g1. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPP, Lube Fit5 are registered trademarks of Fire Protection Products, Inc.LA FBC', BlazeMastettm, FlowGuard Gold5 and Corzan5 are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. F P P I Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. 46 Features Low Odor Low Smoke FR.C/11 SYSTEM COMPATIBLE *FBCfl System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. D 3198 UONSHEAD AVE THREAD CUTTING OILS OR CARLSBAD, CA 92010 TEL + 1760 599-1168 CONTAMINANTS. +1800344-1822 FAX + 1800 344-3775 Nu © 2013 Fire Protection Products, Inc. FPPFi, ThreadRe are registered trademarks of Fire Protection Products, Inc. MADI IN U.S.A. Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER I- THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change Spears® Compatible oil regularly for optimum indicates that performance. Contains petroleum ThreadFit® CLEAR oil. Avoid breathing mists or has been tested by Spears® vapors. Avoid eye contact and Manufacturing to prolonged or repeated contact be compatible with with skin. Wear safety glasses Flameguard® pipe and or goggles. Use good personal fittings. hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish