Loading...
HomeMy WebLinkAbout6211 EL CAMINO REAL; ; AS160348; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160348 6211 ELCAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 2131001500 Lot #: 0 Reference No.: Status: ISSUED Applied 10/27/2016 Approved: 10/27/2016 Issued: 10/27/2016 PC #: Inspector: Project Title: AS160348 RELOCATE AND ADD NEW SPRINKLERS TO ACCOMMODATE FOR NEW WALLS. NEW FIRE SPRINKLER WILL BE INSTALLED CENTER TILE. Applicant: COSCO FIRE PROTECTION FELIPE ALVAREZ 4990 GREEN CRAIG LN SAN DIEGO, CA 858-444-2000 Owner: 6211 EL CAMINO REAL L L C P0 BOX 927729 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 303 ,S .00 000, cosco .. I..,. '..•: I Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www.coscoflre.com MATERIAL SUBMITTAL Date: 10/14/16 SAFC 6211 6211 EL CAMINO REAL CARLSBAD, CA 92009 s JOB # 1O.CD_57 17 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: Felipe Alvarez AS 1 60348 6211 ELCAMINO REAL Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle December 4, 2013 Sprinkler 41a MICROFAST® AND MicrofastHP® QUICK "ij IF(II1G RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Microfast and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resist- ant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE CE Certified: Standard EN 12259-1, EC-certificates of conformity 0786-CPD-40130, 0786-CPD-40170 and 0786-CPD- 40279, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987 Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http:llwww.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 12979, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cii000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT coated. Form No. F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 06932B to VK3311.) S p H rk1 Protec S hie I c Wrench Protective Spr'irk1r Cap I r=10896 (D Sprinkler 41 b December 4, 2013 MICROFAST® AND MicrofastHP® QUICK "ritJ II(II1G® RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfast and MicrofastHP11 Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, and 286°F (141 °C) = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B° (available since 2011) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool— Part No. 15915 (available since 2010.) *A 1/2 ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) . 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. . I I INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance require- ments. AVAILABILITY The Viking Microfast® and MicrofastHPO Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/B 0 December 4, 2013 Sprinkler 41 c MICROFAST® AND MicrofastHP® QUICK N I Ki W4 RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com TABLE 1: AVAILABLE SPRINKLER lTEMPERATURE -Or ft Ordinary 135 °F (57 C) 100 F (38 C) Orange Ordinary 155 °F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200°F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C). Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler Wrench '- - — / 16036'eJ/B)( for installing recessed t[] []JI penclervt sprinklers [] []J AAA 1/2' ratchet is required \===f (not available from Viking). A Carefully slide the J A IIE E = = I wrench sideways 11 1 around the protective cap ensuring engage- ment with the sprinkler wrench flats. Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers I 0 Sprinkler 41d December 4, 2013 N11UW(& MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Z—r Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No." NPT BSP U.S. metric2 Inches mm cULus4 NYC5 VdS LPCB I Standard Orifice 12979 VK302 1/2" 15 mm 56 80.6 2-1/4" 57 AIX, 131Y, C4, E4Z AiX, 131Y -- - - -- 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, 131Y AiX, 131Y A2 A2X, B2Y C2x, E2Y11 C2x, E2Y14 Large Orifice 06666B VK352 3/4" 20 mm 80 115.2 2-3/8" 60 AiX, 131Y, C4, E4Z AiX, 131Y A2 A2X C211 -- 06765B15 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 1 AiX, 131Y, C4, E4Z Aix, BiY A2 -- A212 -- Small Orifice' 06718139 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX, BiY AiX, 131Y -- -- -- -- 06720B9 VK331 1/2" 15 mm 4.2 57 2-1/4" 58 AiX, 131Y Aix, BiY -- -- -- -- 06932B VK3311 -- 10 mm 4.2 57 2-3/8" 60 -- -- A2 -- G313 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric2 Inches mm cULus4 NYC'- VdS LPCB 12282 VK317 1/2" 15mm 5.6 80.6 2-1/4" 58 AiX, BiY AiX -- -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifice' 1229010 1 VK342 1/2" 1 15 mm F2.8 40.3 2-3/16" 56 AiX, BiY AiX -- -- -- -- Approved Temperature Ratings Approved Escutcheons A - 135 "F (57 CC), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and Approved Finishes X - Standard surface-mounted escutcheon or B -135 F (57 C). 155 F (68 C), 175 F(79 C), and 200 F(93 C) 1 - Brass, Chrome, White Polyester.', Black Polyester6'7, and Black PTFEt the Viking Microfast9 Model F-i Adjustable Escutcheon C - 155 F (68 C), 175 F (79 C), 200 F (93 C), and 286 F (141 C) 2 - Brass, Chrome, White Polyester 7, and Black Y - Standard surface-mounted escutcheon or Polyester7 the Viking Microfast® Model F-i Adjustable D - 135 °F (57 °C), 155 "F (68 "C), 175 "F (79 "C), and 286 "F (141 3 Brass and Chrome Escutcheon or recessed with the Viking "C) - Micromatic5 Model E-i, E-2, or E-3 Recessed E - 155°F (68 "C), 175°F (79 °C), and 200°F (93 °C) 4- ENT' Escutcheon F - 155 °F (68 °C), 175 °F (79 °C), and 286 °F (141 °C) Z - Standard surface-mounted escutcheon or re- G - 155 °F (68 °C) ceased with the Viking Micromatic5 Model E-i Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 0 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. ((Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 2 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40279. ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 14 • MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1 003 and 0832-MED-1 008. ' The 1/2° NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. December 4, 2013 Sprinkler 41e MICROFAST® AND MicrofastHP® QUICK 'ij II(411%IG;® RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com I '" -, . ,•. cULus Listing Requirements: Microfast® and MicrofastHPO Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. CeRing Opening Size 2-5/16' (58.7 mm) minimum I 2-1/8' 2-1/2' (63.5 mm) maximum (54 mm) - S 1/2' (15 mm) NPT mm)IrL 1-5/8' (41 Pendent Sprinkler 1-3/4' (44.5 mm) Installed with a standard 1/8' surface- mounted escutcheon, L__J$ 2' TJ 1-1/2' (38.1 mm) (50.8 mm) \ Minimum Maximum Installed with a Microfast Model F-i Adjustable Escutcheon * Note At maximum, adapter is exposed 1/2' (12.7 mm) from face of ceiling. Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon I 2-1/8" I Ceiling Opening Size: I 2-1/8" I I.'. 2-1/2" (635 mm) maximum (54 ) 2-5/16" (58.7 mm) minimum I (54 mm) 1-3/4" Minimum I 1-1/8" (28,6 mm) (44.5 mm) Maximum Installed with a Micromatic Model E-1 Recessed Escutcheon 1-1/8" (28,6 mm) (50,8 mm) \2 Minimum Maximum __________ Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons S Sprinkler 41f December 4, 2013 MICROFAST® AND MicrofastHP® QUICK III(I I1Gi RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Sprinkler SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 Base Part No.' NPT I BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A2X, 132Y, C3, D3Z 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, B2Y Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 A2X, B2Y, C3, D3Z 06765B7 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A2X, B2Y, C3, D3Z Small Orifice' 06718B6 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX Approved Temperature Ratings Approved Escutcheons A - 135 ¶ (57 °C), 155 °F (68 °C) 175 °F (79 °C) X - Standard surface-mounted escutcheon or the Viking 200 °F (93 °C), and 286 °F (141 °C) Approved Finishes Microfast Model F-i Adjustable Escutcheon 135°F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 1 - Brass and Chrome Y - Standard surface-mounted escutcheon or the and 200 °F (93 °C) 2 - Brass, Chrome, White Polyester', and Viking Microfast® Model F-i Adjustable Escutcheon 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), Black Polyester' or recessed with the Viking Micromatic® Model E-1, and 286 °F (141 °C) 3 - ENT E-2, or E-3 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Z - Standard surface-mounted escutcheon or recessed (93 C) with the Viking Micromatic® Model E-1 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. FM approved as corrosion resistant. FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. fSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 13ia-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for gen- eral care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 06932B to VK3311.) February 26, 2014 Sprinkler 105a QUICK RESPONSE 40 DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish I may change color. This natural discoloration over time is not in itself an indica- tion of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 - NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requiements, and refer to Approval Chart 2 and Design Criteria on page lOSe for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Viking Technical Data may be found on Compression Screw: Brass UNS-C36000 The Viking Corporation's Web site at Pip Cap: Brass U NS-C31 400 or UN5C31600 Ittp:llwww.vikinggroupinc.com. Pip Cap Adapter: Brass UNSC36000 The Web site may include a more recent Orifice: Copper UNS-C22000 or UNS-C11000 edition of this Technical Data Page. Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-530400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Form No. F_031793 Replaces page 105a-f, dated July 17, 2013. (Removed Seal Part Number) L-1 Sprinkler 105b February 26, 2014 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-530400 Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a madetoorderr basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 07297W/B (available since 1991) Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A 1/2" ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 07741 Recessed Dry Escutcheon Cup: Base Part No. 05459A INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current Figure 1: Standard Sprinkler Wrench 07297W/13 Sprinkler Wrench 0 7565W/B** must be I / used For installing I / recessed dry / sprinklers r / Step 2: Carefully press 113T IF If the wrench upward and turn slightly to ensure engagement with the sprinkler wrench Flats. Step 1: Carefully J **A l/P ratchet is slide the wrench required (Not avail- sideways around the able From Viking.) sprinkler deflector, Figure 2: Wrench 07565W/113 for Adjustable Recessed Dry Pendent Sprinklers February 26, 2014 Sprinkler 105c 41J IKJNG4 ® QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com M 10:1 11111 Me * =4 41 Ordinary 155 "F (68 "C) 100 "F (38 "C) Red Intermediate 175 "F (79 "C) 150 "F (65 °C) Yellow Intermediate 200 °F (93 "C) 150 °F (65 °C) Green High 286T (141 "C) 225 °F (107 "C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating 1,4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For "A" Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2" (12.7 mm) between 1-1/2" and 45-1/2" (38.1 mm and 1,156 mm). NOTE: The deflector will be located approximately 3-7/16" (87.3 mm) below the ceiling with 1" (25.4 mm) upward and 1" (25,4 mm) downward adjustment Deflector at minimum distance below ceiling. NOTE: To locate the deflector at the minimum distance below the ceiling, with ______ no downward adjustment Minimum ceiling opening /16 available, order the diameter: 1-3/4" (44.5 mm). t (61.9 mm) dry pendent sprinkler Minimum Maximum ceiling opening j i" (25.4 mm) shorter diameter: 2-1/4" (57 mm), than the "A" dimension, 16' _________ NOTE: Finished —(20.6 mm) - I Ceiling r To locate the deflector at the maximum distance 4-7/16" below the ceiling, with 1-1/2' Sleeve finish (112.7 mm) no downward adjustment (38.1 mm) matches escutcheon, Maximum diameter available, order the dry pendent sprinkler 1" (25.4 mm) longer (77,8 mm) than the 'A" dimension. Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler C Sprinkler 105d February 26, 2014 j IF(1IS1GJ Lu.YM QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Thread Size ' Nominal KFactor2' Order Length Increment ' Listings and Approvals4 B Part N SIN Style Base a o. - U.S. metric 3 Inches mm cULus5 NYC' VdS LPCB CE • NPT BSP 08383U Adjustable 1" -- 5.6 80.6 1/2" 12.7 All, A5 Al -- -- -- -- VK176 16457U Standard -- 25 mm -- 80.6 1/2" 12.7 Al, A5 -- -- -- -- -- 08385U Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- -- -- VK180 16453U Recessed -- 25 mm -- 80.6 1/4" 6.35 B2, B6 -- -- -- -- -- 08387U Plain 1" -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- -- -- VK172 16455U Barrel ______ 125 mm -- 80.6 1/2" 12.7 1 A3 I -- -- -- -- -- Approved Finishes and "A" Dimensions 1 - Chrome or White Polyester7 sprinkler with a Chrome or White Polyester Sleeve and Escutcheon Approved Temperature Ratings with "A" dimensions 1-1/2" 1045-1/2" (38.1 mm to 1,156 mm) A - 155 "F (68 "C), 175 "F (79°C), 200 "F (93 "C), 2 - Chrome or White Polyester7 with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) and 286 °F (141 "C) 3- Chrome, Brass, White Polyester7, or ENT with "A" dimensions 31047" (76.2 mm to 1,194 mm) B - 155 "F (68 °C), 175 °F (79°C), and 200 "F 4-Chrome or Brass with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) (93 "C) 5 - ENT7 sprinkler with an ENT7 Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 6- ENT' with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. cULus Listed as corrosion resistant. NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page S DRYI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. I I February 26, 2014 Sprinkler 105e J 11(1 I41G lII[I1U'7M QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Sprinkler Base 1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment' FM Approvals4 NPT BSP U.S. ' metric' Inches mm Part No.' (Refer also to Design Criteria below.) 08383U VK176 Adjustable Standard 1" -- 5.6 80.6 1/2' 12.7 Al 16457U 25 -;:;: -- 80.6 1/2" 12.7 Al 08385U VK180 Adjustable Recessed 1" -- 5.6 80.6 1/4" 6.35 B2 16453U -- 25 mm -- 80.6 1/4" 6.35 B2 08387U VK172 Plain Barrel 1" -- 5.6 80.6 1/2" 12.7 A3 16455U -- 25mm -- 80.6 1 112" 1 12.7 1 A3 Approved Temperature Ratings Approved Finishes and "A" Dimensions A- 155°F (68 °C) 175°F (79 °C) 200°F (93 °C) 1 - Brass, Chrome, White Polyester, or ENT° sprinkler with a Brass, Chrome, White Polyester, or "A" ENT' Sleeve and Escutcheon with dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) and 286 oF (141 C) 2 - Brass, Chrome, White Polyester, or ENT' with 'A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) B -155°F (68 °C), 175°F (79°C), and 200°F (93 °C) 3-Brass, Chrome, White Polyester, or ENT5 with "A" dimensions 31047" (76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. FM approved as corrosion resistant. DEGN çRfTE1iA - F (Also re1rto Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ- ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F .091699 - Care and Handling of Sprinklers. Also refer to page DRYI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. For"A Dimension 6A )B I 1. Determinethe distance I from foce tee to r 'A' Dimension: the finisheof ceiling, A 2. Round to nearest 1/4' O d ' A 1. Determine the Minimum ceiling opening: (6.35 nn) between distance from Outside the face of the 3-1/4' (82.5 sri) and 2-1/8' (54 nn) diasete 47-1/2' (1207 ) cOorieter: tee to the base 1-5/16' ofthe sprinkler. Maximum ceiling opening 2-1/2" (63.5 mm) diameter, NOTE: Sprinkler will be (33,4 sri) 2 Round up to the (sane recessed approximately 05 next highest 1/2' (25 rim) (12.7 mm) incrie- 5/16' (7.9 sri) above Schedule sent between 3" the finished ceiling with 40 pipe). (76,2 rim) ond Adjustment: 5/8' (15.8 mm) vertical 47" (1,194 mm). ___________ adjustment available, 5/16' (7.9 mm) ___________ __________ 5/16' (7.9 nn) Finished ceiling 1-5/8" Minimum: 1' (25.4 sri) I (48.3 mm) Maximum: 1-5/8' (42.1 sri) 3-1/16' (77.9 mn) Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler Sprinkler 105f February 26, 2014 El .J II(IF4,1G ® lil:Il[.11u.rM QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Ambient Exposed Barrel Ambient Temperature Temperature 40°F/4°C150°r/10°0160°F/16°C of Protected Area* at the Exposed Minimum Barrel Discharge End Lercgthww Face of Tee of the Sprinkler to Top of Ceiling n) m) nm) 40F (4°C) 0 0 1 0 30°F (-1°C) 1 0 0 0 20°F (-7°C) 4 (100) 0 10°F (-12°C) 0(203) 1(25 0F (-10°C) 12 (305)- 3(76) -10F (-23°C) 14 (356) 4(102) 1(25.4) -20°F (-29°C) 14 (356) 6 (152) 3 (76) -30°F (-34°C) 16 (406)8(203) 4(102) -40°F (-40°C) 11 45 0<203) 4<102) (-46°C) 20(5 00)10(254 6(152) -60°F (-51°C) 120(508)10(25416 (155 Install 1 inch NPT threaded Deflector at end of dry pendent sprinkler minimum distance into the 1 inch NPT outlet below ceiling of a malleable iron tee fitting per ANSI B 163 (Class 150) or cast iron threaded tee fitting Up to 2' (50.8 mm) per ANSI 16.4 (Class 125) only, adjustment available, Note: Minimum ceiling opening diameter: ________ _______ _z: HE _ To locate the 1-3/4' (44.5 mm) (Exposed deflector at the Barrel) Maximum ceiling opening diameter: j'7/16' minimum distance 2-1/4° (57 mm), _______ below the ceiling, (61.9 mm) with no upward Seal the clearance ' I space around the I able order the sprinkler to avoid leak- dry pendent sprink- _____ age of air into the M shorert the ler 1' (25.4 mm) ,-L 13 /16' protecte( or Ceiling _J (0,6 mm) °' ' °"' of condensate around ' the frame, which could Note: inhibit operation or To locate the 1-1/2' (38.1 mm) Sleeve finish cause premature opera- 4-7/16' deflector at the diameter matches tion. Refer to Figure (112.7 mm) maximum distance escutcheon below, Maximum below the ceiling, with no downward If humidity and temp- djustment avail- 3-1/16' erature differential d ble, order the (Protected Area) causes conensation (77.8 mm) on the exposed dry __j_ y pendent sprink-ar 1' (25.4 mm) sprinkler, consider longer than the wrapping the exposed Deflector at 'A' dimension. barrel with insulation, maximum distance foam insulating tape, below ceiling or equivalent. The protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. wceThe minimum required barrel length is not the some as the 'A' dimension. Refer to Figures 3-5 for the 'A' dimension. NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) S Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 Replaces page 105a-f, dated July 17, 2013. (Removed Seal Part Number) tqca Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TY-B - 2.8, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this technical data sheet are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commer- cial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TV-B Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10(1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE The Series 1Y-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contract the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY1151 - Upright 2.8K, 1/2-NPT TY1251 - Pendent 2.8K, 1/2" NPT TY3151 - Upright 5.6K, 1/2" NPT TY3251 - Pendent 5.61K, 1/2" NPT 1Y4151 - Upright 8.01K, 3/4" NPT TY4251 - Pendent 8.01K, 3/4-NPT 1Y4851 - Upright 8.0K, 1/2" NPT TY4951 - Pendent 8.0K, 1/2" NPT Page 1 of 8 NOVEMBER 2014 TFPI5I TFPI5I Page 2 of 8 7/16 (11,1 mm) I NOMINAL I MAKE-IN 2-3/16 5,6 mm) p 1/2 NPT** T WRENCH FLATS UPRIGHT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 3 - Sealing 6 - Deflector* Assembly 7 - Bushing 1 4 -Bulb 2-1/4 (57,2 mm) * Temperature rating is indicated on Deflector. 1-9/16" (39,7 mm) I ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. PENDENT CROSS SECTION FIGURE 1 SERIES TV-B UPRIGHT 'TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE ESCUTCHEON PLATE SEATING SURFACE Im) ___ 7/16 NOMIN MAKE-IN AL 2-3/16" 11,1 m (55,6 mm) 2-3/16" 1-1/2" _____ (55,6 mm) (38,1 mm) 1/2" NPT** f WRENCH FLATS UPRIGHT PENDENT FIGURE 2 SERIES TV-B UPRIGHT (TY3 151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE 0 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* / I\ R2 r -5 STYLE 10 [- 2-7/8 (73,0 mm) DIA. RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION CROSS SECTION TFPI5I Page 3 of 8 1 - Frame 3 - Sealing 5 - Compression ESCUTCHEON 2 - Button Assembly Screw PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 ;3/4" ___ 2J16 (12,7mm) NOMINAL I MAKE-IN (58,7 (57,2mm)/(397mm) mm) 2-1/4 1-9/16 ** WRENCH STYLE 40 -.---- 2-7/8 (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT FIGURE 3 SERIES TY-B UPRIGHT (TY4 151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT, STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 3 - Sealing 6 - Deflector* Assembly 4 - Bulb 7/16 ________ / 2-1/4 (11,1 mm) r (57,2 mm) 2 NOMINAL * Temperature rating is MAKE-IN 23/16 1-9/16 indicated on Deflector. (55,6mm) (39,7 mm) Pipe thread connections 6* per ISO 7-1 can be provided on special 1/2 NPT** WRENCH request. UPRIGHT FLATS PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR 1/2 INCH NPT, STANDARD RESPONSE * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. S n TFPI5I Page 4 of 8 K SPRINKLER TYPE TEMPERATURE RATING BULB LIQUID COLOR SPRINKLER FINISH (8) NATURAL BRASS I I CHROME PLATED I POLYESTER*** I LEAD COATED I WAX TED COA I COATED WAX-OVER-LEAD 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT 2.8 NPT (TY1151) and PENDENT (TY1251) 1, 2, 3 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Figure 1 Blue 360°F(182°C) Mauve 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT (TY3151) and PENDENT (TY3251) 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2, 3,5 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1°°, 2**, V, 5** 2**, 5.6 Figure 2 360°F (182°C) Mauve N/A 1/2" NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY3251)* 1,2,3,4, 5 N/A 175°F(79°C) Yellow 200°F (93°C) Green Figure 5 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT (TY4151) and PENDENT (TY4251) 1,2,3,4,5,6,7 1,2,5 1,2,3,5 1,2,5 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1°°, 2°°, 3",5— 1, 2°f, 5** 8.0 Figure 3 360°F(182°C) Mauve N/A 3/4 NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY4251)* 1, 2, 3, 4, 5 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155-F (68-C) Red UPRIGHT 8.0 1/2" NPT (TY4851) and PENDENT (TY4951) 1, 3,4,5,6 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F (182°C) Mauve Notes: Listed by underwriters Laboratories, Inc. (UL) Listed by underwriters Laboratories, Inc. for use in Canada )C-UL) Approved by FM Global (FM Approvals) Approved by the Loss Prevention Certification Board )LPCB Ref. No. 007k/03) Approved by the City of New York under MEA 354-01-E VdS Approved (For details contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-3-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Where Lead Coated, Was Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. * Installed with Style 10 )1/2 NPT) or Style 40)3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable 150*F )66*C) maximum ceiling temperature Frame and deflector only N/A - Not Applicable TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME TER* POLYESTER* LEAD WAX WAX-OVER-LEAD BRASS PLATED COATED COATED COATED 2.8 UPRIGHT (TY1151) 1/2' and 175 psi (12,1 bar) N/A NPT I PENDENT (TY1251) UPRIGHT (TY3151) and 5.6 PENDENT (TY3251) 250 psi (17,2 bar) (a) 1/2' OR NPT 175 psi (12,1 bar) RECESSED PENDENT (TY3251) UPRIGHT (TY4151) and 175 psi (12,1 bar) 8.0 PENDENT (TY4251) 3/4' NPT RECES .D251 PEpDENT 175 psi (12,1 bar) N/A 8.0 UPRIGHT (TY4851) 1/2' and 175 psi (12,1 bar) NPT PENDENT (TY4951) Notes: a. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. * Frame and deflector only N/A - Not Applicable TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE S Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved VdS Approved NYC Approved (Refer to Table A for complete ap- proval information, including corro- sion-resis-tant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=2.8 gpm/psi112 (40,3 pm/bar1'2) K=5.6 gpm/ps1112 (80,6 1pm/bar1/2) K=8.0 gpm/ps11'2 (115,2 pm/bar1'2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame .......................Bronze Button..................Brass/Copper Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb .........................Glass Coripression Screw............Bronze Deiector ..................... Copper Bushing (K=2.8) ...............Bronze Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the flud expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Spriiklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Global Loss Prevention Data Sheets). Only the Style 10 r 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. - 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4 (6,4 mm) I I FACE OF L.572 mm1 MOUNTING SPRINKLER PLATE FITTING J rH 1/8 / (3,2 mm) MOUNTING SURFACE SERIES 1-1/4 (31,8 mm) CLOSURE TY-B 3/4' (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 0 2-7/8 DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4(6,4mm) (57,2 mm) MOUNTING DI AT 5/8±1/4 (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-B 1/8" (3,2 mm) 1-5/16" (33,3 mm) 13/16(20,6mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFPI5I Page 6 of 8 WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4" NPT MODELS) FIGURE 7 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W- TYPE 7 RECESSED SPRINKLER WRENCH Installation TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. TFPI5I Page 7 of 8 Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Note: Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 7). For wax-coated sprinklers, use an 8 or 10 inch adjustable wrench. With reference to Figures 1 through 4, the W-Type 7 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, is to be applied to the sprinkler wrench flats. When installing wax-coated sprinklers with an adjustable wrench, exercise care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. Open the jaws of the wrench sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprinkler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating when- ever the coating has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau- tions need to be taken when handling the heated rod in order to prevent the installer from being burned. Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installation Section.) The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. S 135 135°F(57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F (182°C) 000 OPEN*** 1 1 NATURAL BRASS PURE WHITE (RAL9010) * POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) ** POLYESTER 6 WAX COATED 286°F (141°C) MAX 7 LEAD COATED 8 WAX-OVER-LEAD 286°F (141°C) MAX 9 I CHROME PLATED TFPI51 Page 8 of 8 0 P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE I FINISH I RATING 530 2.8K UPRIGHT (1/2" NPT) TY1151 531 2.8K PENDENT (1/2" NPT) 1Y1251 570 5.6K UPRIGHT (1/2" NPT) TY3151 571 5.6K PENDENT (1/2" NPT) TY3251 590 8.0K UPRIGHT (3/4" NPT) 1Y4151 591 8.0K PENDENT (3/4 NPT) TY4251 560 8.0K UPRIGHT (1/2" NPT) TY4851 561 8.0K PENDENT (1/2" NPT) TY4951 Notes: * Eastern Hemisphere sales only ** Available in only 8.0K, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture Available only for 8.0 K-factor 1Y4151 and TY4251 for use in deluge systems ('OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly) TABLE C SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify) finish, P/N* * Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench-damaged wax coating) Specify: (specify color, below) Colored Coded Wax Stick for retouching (specify temperature rating) temperature-rated Series TV-B Sprinklers, P/N (specify) Black for 135°F (57°C) ..,,,, P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F (93°C) sprinklers, and, therefore, the 286'F(141 *Q sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler (i.e., 1500F[66°C]). GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqcn TEFLON is trademark of the DuPont Corporation. Fire Protection Products FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES 1 [ J[mm...l[ [ts.itt. [ kg/rn CRR* In. mm . in. mm Lift_] Approvals and Specifications Both products meet or exceed 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7,3 61 the following standards: r - '••-- 1Y 1.900 48,3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 ASTM A135, Type E, Grade A (Schedule 10) 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 ASTM A795, Type E, Grade A (Schedule 40) .... . 73.0 2.635 66.9 ' 3.05 3.53 5.26 3.5 2.875 . .120 30 NFPA 13 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 Manufacturing Protocols -, 1 5.62 8.37 1,6 4 4.500 114.3 .. 4.260 108.2 .120 3.05 JI 19 Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 ensure the highest quality and long-lasting performance. ' . 6.625 168.3 6.357 I 161.5 134 340 930 1385 10 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Finishes and Coatings All Wheatland black steel fire sprinkler pipe Calculated using Standard UL CRR formula, UI. Fire Protection Directory, Category VIZY. up to 6" receives a mill coating to proprietary The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black, or with hot-dip galvanizing, to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES FM/UL requirements for dry systems that meet .1 In. mm in. mm LIbs./ftj(jiCRR* in. mm Lift {___] the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is 1 1,315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 also UL Listed. tr , 1.00 1.660 1 11 42.2 1.380 35.1 r 140 356 3.39 2.27 r 51 Product Marking 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler - JI pipe is continuously stenciled to show 2 2375 603 2.067 52.5 .154 391 366 5.45 1.00 .... ' 1 30 the manufacturer, type of pipe, grade, size * Calculated using Standard UI. CRR formula, UI. Fire Protection Directory, Category WZY. and length. Barcoding is acceptable as a * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. supplementary identification method. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). C& APPROVED SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK ' El HOT-DIP GALVANIZED Wheatland Tube 700 P 800.257.8182 1 f s; Dock Street C.I. THREADED FITTINGS FITTINGS Divio,,o/SW, Pipe Pdc LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME 1316.14. THREADS ARE NPT PER ANSI/ASME B1.20.1. iCASTIIRONIeI. DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS EIGHT I A B EACH IECE [1.34 1 CB90033 300 1.50 1.500.95 11/4 CB90044 300 1.75 1.75 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 1 2.25 1 2.25 2.90 21/2 CB90077 300 2.70 1 2.70 4.75 CAST1IRON RED. COUPLING NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST IRON uRED. I'JDEG. NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1X1/2 CB90031 300 1.26 1.36 0.6Z- 1 X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 I C890041 300 1 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1 1.73 2.02 2.10 2X1 1/4 CB90064 300 -_300 1.90 2.10 2.30 2X1 1/ I CB90065 2.02 2.16 2.60 Page 38 CAST iiIRON ;1 [e] I NOMINAL SIZE (INCH) ITEM CODE MAX. P.S.I. WEIGHT ' PIECE WORKING EACH ZB 1 CT333 300 1.21 11/4 CT444 300 1.87 11/2 CT555 300 1.94 1.94 2.51 2 CT666 300 2.25 2.25 3.96 21/2 C1777 300 2.70 2.70 6.45 CASTIIRON 45 DEGREE ELBO NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT' EACH PIECE A B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 C845055 300 1.43 1.43 1.80 2 1 CB450661 300 1 1.68 1 1.68 1 2.79 CASTIpIRON IPLUGS NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. I01M 0NI WEIGHT' EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 CAST IRON REDUCING TEE NOMINAL SIZE (INCH) I ITEM CODE _ ______ ' MAX. WORKING P.S.I. DIM1SIONS I WEIGHT I EACH PIECE A B C 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/471 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.26 1.53 1.17 1 1/4X1 X3/4 CT 32 300 j1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.571.47 1 1.50 1/4X1X1 1/4 CT434 300 1.67 1.75 1.80 - 1 1/4X1X1 1/2 CT435 300 1.80 1.82 --Tug 1 1/4X1 1/4X112 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 C1443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 0T445 300 1.88 1.88 1.82 2.21 1 1/471 1/4X2 CT446 300 2.10 2.10 1 1/2X1 X112 CT531 300 1.41 1.34 1 1/2X1X3/4 0T532 300 1.52 1.37 1 112X1 X1 CT533 300 1.65 1.50 n.6 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1 1/2X1 1/4X314 GT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 0T545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 0T663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 1 300 2.02 2.02 2.16 3.72 2x2x2 1/2 CT667 1 300 2.60 2.60 2.39 5.10 0 S C.I. THREADED FITTINGS FITTINGS * (~~ <*> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRONt'Ft1* I NOMINAL SIZE (INCH) ITEM CODE ' MAX. WORKING P.S.I. DIMBISIONSI WEIGHT' EACH PIECE - A - B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 Page 39 Th FireLock Outlet-T STYLE 922 For Complete Information Request Publication 10.52 Incorporates ½-1710-25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products UL/ULC Listed, LPCB, VdS/FM Approved for is branch connections on wet and dry systems Style 922 FireLock Cutlet-Ts are not approved for cross configurations Pressure rated up to 300 psi/2065 kPa and rated up to 230 psi/16 Bar at the ambient temperatures typical for fire protection systems Sizes from 1'4x½"/32x 15 mm through 2½x 1/76.1 x25 mm t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). TYPICAL FOR ALL SIZES Hole Cut Piping System Size Run x Branch Hole Diameter ,111111,k1[,I.k Approx. Wgt. Each Inches +0.06/+I.S Inches Inches iiWIT! r____ M111 mm mm mm kg 1¼ ½ X 1,16 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 1A 1 316 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 5 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ ½ X 1 3A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 31 1,16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 1 41.7 58.4 31.0 103.6 65.0 0.59 2 ½ 13A6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/4 13A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0,64 1 13A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 1/2 X 1316 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1316 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 'A6 2.13 2.79 1.71 5.40 2.56 1,6 25 30.2 54,1 70.9 43.4 137,2 65.0 0.73 1/2 1316 1.91 2.44 1.71 5.50 2.56 1.6 761 mm x 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/~ 11/6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1316 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 5-9 X Xictolullie WWW.VICTAULIC.COM G-105 FIRE PROTECTION CATALOG MechanicaIT® STYLES 920 AND 920N Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. am STYLE 920 CROSS PATENTED STYLES 920 AND 920N MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized S Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com viciuic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K Para . \4taulicr 11.02_i JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved DIMENSIONS GROOVED OUTLET 11 Willi, " S FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psiI3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size St, le Nc. Max. Work Pressure@ Dimensions Approx. Weight Each Inches mm or 920N psi kPa +0.13 -0.00 Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Lbs. Lbs. kg kg 50 15 3450 38.1 51 64 - 41 136 70 - 1.5 IK (a) a 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) u 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 1 54(a) (a 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1½ (a) to920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 x 1/2 (a) §0 920N 500 1.50 2.21 2.74 91.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 '/4 (a) §0920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §n920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 1 1/4 ((a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1h ((a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 761 x 1/2 (a) 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 164 81 1.8 - 3/4 (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 164 81 1.8 - 1(a) 920N 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 - 57 164 81 1.7 - 1 1/4 (a) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1½ (a) a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 x 1/2 (a) a 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - 54(a) a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 1 3450 38.1 63 78 - 58 156 70 1.6 - 1(a) 920~ 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 70 1.6 - 11A (a) (a 920~ 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 ½ (a) to 920~ 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 . 58 156 83 1.9 1.8 2 (a) a 920~ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31/2 2 920½ 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 63.5 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 aa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. S www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 JtauIicr REV_K DIMENSIONS Vaal -11 WIN %Ii GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Dimensions TABLE CONTINUED FROM PAGE' 4 ½ (a) D 1 500 1 50 3.03 3.56 269 701 275 3.7 - 100 X 15 920½ 3450 381 1 77 90 68 178 70 18 34(a) 1 500 1.50 3,00 3.56 2.69 7.01 2.75 3.7 20 920N [ 3450 38.1 76 90 - 68 178 70 1.8 - 1(a) D 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 920½ 3450 38.1 73 90 68 178 70 1.8 - - 1.75 3.08 3.78 4,00 2.69 7.01 3.00 4.0 3.6 1 /4 (a) 'D 920N 500 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2 (a) to 920½ 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40 (b) 3450 50.8 83 2 (a) to 920½ 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 23 21 21/2 (a) I' 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5,0 65 3450 69.9 73 102 102 68 186 118 2.6 23 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 102 68 186 08 29 3(a) I' 920 .500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 1080 X 1 ,t(a)D 920½ 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 - 32 3450 44.5 78 96 - 67 194 78 2.3 1½)a(u 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 - 67 194 83 23 2 (a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 -102 102 67 194 9 16 3.5 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 - 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 1½ (a) I' 920 500 2.00 4.03 4.75 4.75 3.16 ' 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a) I' 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 2½ (a) 6 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm 1 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 3 (a) 6 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 1330 x 920½ 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 50 3450 63.5 95 114 - 81 203 99 920 500 3.50 3.81 5.00 3.00 9.46 1 5.31 8.0 80 3450 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services u _PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com . , \,4tauIiC vicTAuLic is A REGISTERED TRADEMARK OF ViCTAULIC COMPANY, © 2010 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV_K 11.023 S CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 r Mechanical-I® Bolted Branch Outlets L. STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. St, le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Run x' Branch Hole vt# V t Female Anches or psi +0.13 Inches :Inches Inches Inches Inches Inches Lbs. Lbs. I'll 920N kPa -0.00 TABLE CONTINUED FROM PAGE 3 139.7 x 0 90N 500 2.00 3.78 450 3.30 823 3.25 7.0 3450 50.8 96 114 84 209 83 3.2 - 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 84 209 99 4.1 - 6 1 4(a) X 920N 500 1.75 4.43 513 513 3.79 9.15 3.25 5.1 4.8 150 3450 44.5 112 130 130 96 232 83 2.3 2.2 14(a) t a 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 - 3450 50.8 112 -130 JL 96 232 83 2.4 2.3 2(a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 76.1 mm n 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 267 118 - 3.8 3(a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 159.0 x 1½(a) 0N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 3450 50.8 112 130 - 92 1 239 1 83 3.5 - 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 1 3.88 8.0 50 3450 63.5 111 130 92 239 99 3.6 - 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114,3 113 - 137 92 239 155 - 4,5 920 500 4.50 3.81 5,75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ViCTAULIC IS REGISTERED TRADEMARK OF VICTAILLIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. I1.02_4 JtauIic REV_K CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET ii 70o" I ls-p lie FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm Style Size No. Max. Work Pressure@ Dimensions met TABLE CONTINUED FROM PAGE 4 1 920N 500 150 388 456 379 934 275 80 165.1 x 25 3450 381 99 116 - 96 237 70 3.6 - 11/4 U 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - 11/2 (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) t a 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 1 4.8 3.8 8 2 (a) t 20 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 x 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 21/2 (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm U 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 - 159 122 316 116 - 5.3 3 92 0 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4 (a) to 20 500 4.50 4.81 6J5 638 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 4 Available with grooved or female threaded outlet. Specify choice on order. 4 Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services r LPCB approved for lire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com - - VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. uctauluc REV_K 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical—I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA 0 Exaggerated for clarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical1® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C,K. Values: = Q2 Where: AP = Where: CV, Q = Flow (GPM) Q = Flow (m3/h) AP = Pressure Drop (psi) v i.iP = Pressure Drop (bar) Q = C x C = Flow Coefficient Q = K x JAP K = Flow Coefficient Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe 0.840 11 15 21.3 2 - 9.4 3/~ 1.050 16 20 26.7 - - 13.7 1 1.315 21 - 8 25 33.7 - 1.8 1 ¼ 1.660 50 48 32 42.7 5 4 6 42.9 41.1 1 ½ 1.900 53 53 40 98.3 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10,5 96 89.1 2 1/2 2.875 119 150 65 73.0 20 12½ 102 128.5 3.000 161 76.1 mm 16 - - 76.1 138.1 3.500 249 237 80 88.9 14 15,5 213.4 203.1 4.500 421 401 100 114.3 20 22 360.8 343.6 1 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1I.02_6 taulid REV_K CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Approval Agency Outlet Size Pipe Rated Working Pressures — psi/kPa jg All 10,40 400 400 400 290 232 362 21/2-6 2.875 - 6.625 65-150 730-1683 2755 2755 2755 1999 1599 2496 21/2-4 2.875 4.500 All OF 300 300 300 290 232 362 65-100 - 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 314 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 34 - 0 40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 0 40 400 - - - 145 - 200 219.1 2755 1000 8 8.625 34 10 300 - 250 - 145 - 200 219.1 2065 1724 1000 8 8.625 34 - '0 0 300 - 300 - 145 200 219.1 ' 2065 2065 1000 - NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel spinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-I unit, 4 - 87100 - 200 MM CARBON STEEL PIPE whici is a combination of the Style 920 Mechanical-I and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-I unit is a full port ball valve which can be mounted on 4/100mm, 5/125mm, 6/150mm and 8'7200 mm diameter pipe. The Style 931 comes with a 2½I65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K \4tauIic 11.02_7 C S Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 1] For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 4/2010 Aic--tnul-icr VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 11.02_K All dimensions in charts and on drawings are in inches. Dimensions shown in Darentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions Biiflè by E"4 Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** ®TOLPQT Double Fastener Strap Side Mounted (B-Line B3183) S .YL us' Size Range: 3/4' (20mm) thru 2" (50mm) CPVC pipe liSTED Material: Pie-Galvanized Steel - Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed or, the top or on the bottom - - - ofabeam. - Approvals: Underwriters Laboratories Listed in the USA (UL) and / Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. / Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from I any rough surface. Easily attaches to the building structure using the I A two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with / I a hex socket attachment be used as installation tools. No impact I 1 I tools (such as a hammer) are allowed. Damage has been known to I 0 result from installations using impact type tools. Nc pie-drilling of a pilot hole in wood is required. ' B Finish: Pre-Galvanized . B Order By: Figure number and pipe size A * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Mex. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size W000 Part No. in. (mm) in. (mm) in. (mm) in. (mm) t. (m) in. (mm) Lbs. (kg) 2/16" (58.7) 1/32" (27.8) 1/16" (30.2) E'/2(1.67) /16')7.9) 9 (4.11_j 24-1 1" (25) 2/8" (66.7) 1/16" (33.3) 1/16" (30.2) 6 (1.83)/16' (7.9) 9 (4.1) I_24-1I4 11/4 (32) _ (16.2) 11/f 138.1) 1/i" (30.2) -C.1/2 (1.981 /i6'(7.9) 11(5.0ij 24-11/2 11/2" (40) 31/4" (82.5) 1/8" (42.3) 1/16" (30.2) 7(2.13)5/16"(7.9)12(54) F-24--2 2"26-311/,(93.7) 121/32" (43.6) 1/16° (30.2) - 8 (2.44) 5J6 (7.9) 15 (6.81T Fig. 25 - Surge Restrainer 0 Size Range: - One size fits 3/4 (20mm) thru 2 (40mm) pipe. I I Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band . hangers ,. to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13 2010 1 edition 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4' (20mm) thru 2" (40mm). - Patent #5,344,108 -cv'. UL Listed Fastener Table Pipe Size Oty Fastener Type Material [ 72 #16x2" Drive screws Wood 2" 1 /t" Lag bolt Wood [2W'-4" 1V2' Lag bolt Wood: 31/2" 2 1/4" x 11/2" Lag bolts Wood [ 4 2 1/4 x2 Lag bolts** Wood 4" 2 1/4" x 1" Tek screws Metal (15 gauge) 4' 2 - 1/4'x 1'Tek screws - Metal (16 gauge) ** No pre-drilling Up Upper Attachments Fig. 58 - Threaded Side Beam Bracket Size Range: /8"-16 rod, pipe sizes 1/2" (15mm) thru 4(100mm) Material: Pre-Galvanized Steel Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept /8' and 1/2" fastener bolts. Per NFPA 13: 1/2" (15mm) thru 2" (50mm) pipe requires /8" fastener, 21/2" (65mm) thru 4' )lO0mm) pipe requires 1/2" fastener.* Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" (100mm) pipe. Finish: Pre-Galvanized Order By: Figure number and finish *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below. 2 - 'It' x 2' Lag Bolts (No Pre-Drilling Up to 4(100mm) pipe Per NFPA 1 - 3/n' or /2 Lag Bolts Up to 4(100mm) pipe 2-#16x 2 Drive Screws 1/2' (15mm) - 4(100mm) pipe 2-#14x 1" Tek Type Screws Larger pipe sizes can be hung with reduced spacing. Part No. Pipe Size Rod A B C Approx. Wt./100 in. (mm) Size in. (mm) in. (mm) in. (mm) Lbs. (kg) 58 1/2" -4" (15- 100) 3/8 -16 2/4" (69.8) 11/2" )38.1) 11/8" (28.6) 14 (6.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B . - Line Fire Protection Solutions 85 Part No. Threads Recommended Load Approx. WtJ100 Ft. & Size Per Inch Lbs. (kN) Lbs. (kg) [ATR'/4"x'L' 20 240)1.07) 12(5.44) AIR /8" x '1' 16 730 (3.24) 29 113.151 [TE'I2 x 1 13 1350 (6.00) 53 (24.04) ATR 5/8" x '1' 11 2160 (9.60) 89 (40.37) [ThTR 314 xl 10 3230 (1437) 123 )5579) AIR hg" x 'L' 9 4480 (15.93) 170 (77.11) For larger sizes consult full line pipe hanger cataog S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Fire Protection Solutions B-Line by1Et4' Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOICO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: /8'-16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F 1399°Cl Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish i-i Standard Design Load Thread Size Thread Length IL 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. )kN) Lbs. (kN) B3205/8 x 3/8 -16 21/2' (63.5) 730 13.251 512 (2.54) ] - B3205-112 X 1/2"-13 21/2 (63.5) 1350 (6.00) 1051 (4.70) [_205_5/8 x L /8'-l1 21/2' (63.5) 2160(9.61) 1692 (7.52) B3205-3/4 x 'L /4"-10 3' (76.2) 3230 (14.37) 2530 (11.25) [ B3205-7/8 x L 7/8'9 31/2 (88.9) 4480 (19.93) 3508 115.60l . AIR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8'-16 thru 11/2"-6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F 399°Cl Finish: Plain or Electro-Ga Ivan ized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. For larger sizes consult full line pipe hanger catalog Fig. 200-1 to 200-2 Fig. 200-21/2 to 200-0 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B:Une by E14t Pipe Hangers .Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel I materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. U Fig. 200 Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg( L..00-1I2 1/2" (15)__ _/"-!! - - _ 31/8" 4t1. .1L 1i(5.0).J 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) [ 200-i r (25) /t"-16 3/8" (85.7) 2/8" (66.7) - 12(5.5) 200_11/4 11/4" (32) /8"-16 33/4" (94.0) 2/e" (73.0) 13 (5.9) L201'I2 11/2" (40) 3/8"_ 16 3 /8" (98.4) 2/8' (73.0) 14 (64)1 200-2 2" (50) /8'-16 41/2" (114.3) 3(76.3) 15 (6.9) 1 2021/2 21/2 (65) /8"-16 5 /8" (142.9) 41/8' (104.1) - 2003 3 (75) 3/8"-16 5/8 (1491) 4 (101.6) 29 (133) - Fig 200S 200-31/2 3l/'(9) "-16 - )133.3) 34 115.61 200-4 4" (100) /8"-16 1/8" (187.3) 5" (127.0) 35 (16.0) 200-5 - 5" (125( 1/2"..13 91/8" (231.8) 61/4" (158.1) 66 130.21 j 200-6 6" (150) 1/2"13 101/8" (257.2) 6/4" (111.4) 73 (33.4) 200-8 - - - 8" (2001 - 1/3 131/8k (333.4) (222 i13 YIAI.1:1 y[.I•JIJ No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a video demoDsfra 00 Eon\ www.itwbuiidex.com) 17 - #14 Black Nut Driver Part # 8113910 i . #14 SW Red Nut Driver Part # 8114910 S - 1/4" 8002957 GST 100 1/4 x1" 25 125 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1 3/8" 8007957 GST 10 1/4 210 (7/16"OSB) 300 25 125 [ 3/6" 8008957 GST 20 1/4x2 1760 filrl 850 1475 25 125 1 3/8" 8068925 GST 20-SS 1/4x2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8x2-1/2' 2113 (Fir) 1500 25 125 1 £k 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4x3" 2060 [Fir) 25 125 1 1/2 8013925 GST 2 1/4 x 2 1760 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" 2275 25 125 1 4Amk ANUFACTURED USE 'ts;;;' (10a, SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins tree. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. FBI% ml ~, MYSl Not less than 2 nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4'& 5" pipe I A* Minimum 2-1/2" from bottom for branch lines. Minimum 3 from bot- tom for mainlines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. No pre-drilling required. Quick to install using the Sammy Flour Joist Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. AMA Watch deo demonst,otiou www.ibebulldex.comJ V HORIZONTAL MOUNT 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8' 8020957 a - 3/8" 8021957 SWG 10 SWG 20 1/4x 1" 1/4x 2" 622 LF1rj 1725 (Fir) 300 1050 25 25 125 1 125 - 3/8' 8073925 SWG 20-SS 1/4x 2" 1725 fia 25 125 1 JSL 3/8* 8022925 SWG 25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 914 SW Red r 3/8" 8023925 SWG 30 1/4 X 3" 1884 IF) 25 125 1 Nut Driver Purl #8114910 * May require pre-drilling; consult joist manufacturer. no nmooew. Eliminates distortion of threaded rod. Accommodates up to 3 '/2" x 12 pitch roof. Allows 17* deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. t/14 Black - . NutDriver I '- 3/8" 8139957 SH-GST2O 1/4x2" 1257 (Fir) 1050 1475 25 125 Pàrt# 8113910 it 1903 Dim. Lumber 1500 3/8* 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45"off vertical 850 @45 25 125 Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45off vertical 25 125 - * May require pre-ddltng; consult joist manufacturer. Dim. Lumber #14 SH Orange - Nut Driver Part # 8273910