Loading...
HomeMy WebLinkAbout6305 EL CAMINO REAL; ; FPC2017-0190; Permit(L'City of Carlsbad Print Date: 03/30/2022 Permit No: FPC2017-0190 Job Address: 6305 EL CAMINO REAL, CARLSBAD, CA 92009-1606 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 07/13/2017 Valuation: $0.00 Lot #: Issued: 07/26/2017 Occupancy Group: Project #: Finaled Close Out: 02/24/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASAT BLDG 6-B11 CONFERENCE ROOM TI -FIRE ALARM Applicant: FPContractor: iii ENTERPRISES THE STEINHILBER CORPORATION MARIO AGUERO 533 5 VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x209 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 1qF%FNP Ln_ FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ViaSat BLDG. 6-13I I Conf. Room Tenant Improvement 6305 El Camino Real Carlsbad, CA 92009 FIRE ALARM SYSTEM MATERIAL DATA SHEETS PILE COPY FPC20I7-0190 6305 El Camino Real FIRE ALARM SYSTEM BILL OF MATERIALS NOTIFIER FPM-1 ADDRESSABLE RELAY MODULE CSFM# 7300-0028:0219 NOTIFIER DNR INNOVAIRFLEX DUCT SMOKE DETECTOR W/NP-100 HEAD CSFM# 3242-1653:0209 SYSTEM SENSOR RTS-151 REMOTE TEST STATION CSFM# 7300-1653:0212 DN-6724:B3 FCM-1(A) & FRM-1(A) NOTIFI ERSeries 0 Control and Relay Modules by Honeywell - General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style V or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashS can® releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). 1 111 EIPWRH Ill Eli PWR fr) '•i 2 Oc2 FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:133 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and T1: Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SM6500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM..1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (LJR=5ms) 1 A 30 VDC Inductive Coded (LIR=2ms) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: °A" suffix indicates ULC Listed model. FCM-1 (A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SM 6500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 931==1 We cannot cover all specific applications or anticipate all requirements. ENGINEERING MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:83 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60429:C1 DNR(A)IDNRW InnovairFiex NOTI Fl ER® Intelligent Non-Relay Photoelectric 0 Duct Smoke Detector by Honeywell -- General The Notifier InnovairFIex® DNR(A) intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 70°C), and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Notifier InnovairFIex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFIex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. Features Photoelectric, integrated low-flow technology. Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/s). Versatile mounting options: square or rectangular configu- ration. Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non-condensing). Patented sampling tube installs from front or back of the detector with no tools required. Cover tamper signal. Increased wiring space with a newly added 3/4" conduit knockout. Available space within housing to accommodate mounting of a relay module. Easily accessible code wheels on sensor head (sold sepa- rately). Clear cover for convenient visual inspection. Remote testing capability. Requires com line power only. Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158°F (-20°C to 70°C). Storage Temperature Range: -22°F to 158°F (-30°C to 70°C). Operating Humidity Range: 0% to 95% relative humidity (non-condensing). Air Duct Velocity: 100 to 4,000 ft/mm (0.5 to 20.32 m/s). Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visi- ble and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT24 VDC Device I Standby I Alarm RA100Z OmA 12 mA Max RTS151/ OmA 12mA Max RTS1 51 KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S91 1, S3705. ULC: S635. DN-60429:C1 • 4/19/2012 - Page 1 of 2 CSFM: 3242-1653:0209. FM approved. Product Line Information NOTE: "A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851 R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851 (A): Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS1 51 (A): Remote test station. RTS151 KEY(A): Remote test station with key lock. Important Note DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. i7 We cannot cover all specific applications or anticipate all requirements. El b dl I .1 ENGINf[RING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-60429:C1 • 4/19/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0209 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Available Accessories APA151 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn, White RA1 OOZ/RA1 OOZA Remote Annunciator RT51 51 Remote Test Station RTS1 Si KEY Remote Test Station with Key RTS2 Multi-Signaling Accessory AOS Add-On Strobe RTS2-AOS Multi-Signaling Accessory Duct Smoke Detector Accessories Expand the versatility of the lnnovairFIex line of duct smoke detectors with System Sensor notification and test accessories. Agency Listings Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sersor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A, The MHR and MHW SpectrAlerf Advance mini-horns feature temporal or continuous tones at higf' and ow volume settings. Their small footprint allows mounting to siigle-gang back boxes for applications where a small device is cesired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent appli:ations. Their red LED provides visual indication of an alarn.concition. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test cuct smoke detectors from a convenient location. For 4-wire detectors, the RTS1 51 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, tie LE) illuminates red for alarm. The RTS2 and RTS2-AOS multi-sianaling accessories are designed to work with InnovairFIex 4-wire cor:venticnal duct smoke detectors. These accessories include a key switch tha: can be used to select one of two connected sensors to be tested, reset, or both by a push button switch, They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. LISTED APPROVED 'ies Specifications, Duct Smoke Detector Accessor -' Voltage Regulated 24VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C 1049°C (32°F to 120°F) Relative Humidity 101093% non-condensing Wire Gauge 12to18AWG Dimensions 4.6"H x 2.9"Wx .45D Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (91033 VDC with Sync-Circuit- Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max, at 8 to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C 1049°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3kHz Wire Gauge 12to18AWG Dimensions 4.6"H x 2.9W x 0.45" D Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 12 mA Dimensions 4.6 H x 2.8W x 1.3" D RTS151 ULS4O11 RTS151 KEY UL 52522 Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 1 OVA @ 32VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions 48" H x 2.90"W x 14"D Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm Response Time 40 seconds max. Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions 4.6"H x 2.75"Wx 1.8D Voltage 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4,8"Wx5.3Hx 1.6D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. SMOKE APA1S1 ULS4O1I RTS2-AOSULS2522 RA1 OOZ UL S2522 MI-lW UL S4011 MHRULS4O11 AOS ©2x 04 w SYSTEM 1 0 System Sensor.or, 3825 Ohio Avenue w & St. Charles, IL 60174 Prupeons subject to th at ngewtho tn°tce.t ten for current product information, including the latest version of this data sheet. ,S1I%I.5OR Phone: 800-SENSOR2 - Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 4 LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev©honeywell.com DESIGN: Models RTS151, RTS151KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct k#V,C operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division