Loading...
HomeMy WebLinkAbout6451 EL CAMINO REAL; ; AS160116; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160116 6451 EL CAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 2130502800 Lot #: 0 Status: ISSUED Applied 5/4/2016 Approved: 5/12/2016 Reference No.: Issued: 5/12/2016 PC #: Inspector: Project Title: NORTH COUNTY MARTIAL ARTS T.l.: ADD (16) PENDENT & (9) UPRIGHT SPRINKLERS TO ACCOMMODATE NEW TI IN EXISTING SPRINKLERED BLDG. Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION SUITE B 9510 PATHWAY STREET SANTEE CA 619-562-3010 Owner: FIRST INDUSTRIAL INVESTMENT II L L C C/O FIRST INDUSTRIAL REALTY TRUST 898 N SEPULVEDA BLVD #750 EL SEGUNDO CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 303 0 303 0 tqco AS 160116 Fire Protection yco-fire.com 6451 EL CAM INO REAL Products Series TYFRB - 28,4.2,5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in this data sheet are quick response, standard coverage, deco- rative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. L!L.)tD1 The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NOVEMBER 2015 - Sprinkler Identification Number (SIN) TY1131 - Upright 2.81K, 1/2 NPT TY1231 - Pendent 2.81K, 1/2" NPT TY2131 - Upright 4.21K, 1/2" NPT TY2231 - Pendent 4.21K, 1/2" NPT TY3131 - Upright 5.61K, 1/2" NPT TY3231 - Pendent 5.61K, 1/2" NPT TY4131 - Upright 8.01K, 3/4" NPT TY4231 - Pendent 8.01K, 3/4" NPT TY4831 - Upright 8.01K, 1/2" NPT TY4931 - Pendent 8.01K, 1/2" NPT TFPI7I TFPI7I Page 2 of 10 21 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 7/16 (11,1 mm) 4 MAKE-IN NOMINAL 16° mm) 2-3/ (55,6mm) /171(37 1/2 NPT** I WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing CROSS SECTION 2-7/8' (73,0 mm) DIA. -i RECESSED PENDENT FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE _____________________________________________________ J(NOMINAL 7/16 (556 mm) 11,1 mm) 2-3/16' MAKE-IN -1/2 11 (38,1mm)(55,6 mm) 1/2 NPT** I WRENCH STYLE 10or20 FLATS RECESSED H— 2-7/8' (73,0 mm) DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector, special request. PLATE SEATING SURFACE ___________________________ JJNOMINAL 7/16 2-3/16 (11,1 mm) (55,6 mm) MAKE-IN 1-1/2 I (38,1 mm) (55,6 mm) / 1/2' NPT** I WRENCH FLATS UPRIGHT PENDENT STYLE 100r20 RECESSED ESCUTCHEON j— 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT TFPI7I Page 3 of 10 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression ESCUTCHEON 2 - Button Assembly Screw PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE N 1/2 _ (12,7 mm) NOMINAL I i 2-5/16 ] MAKE-IN (58,7 mm) 2-1/4 1-9/16' (57,2 mm)/ (39,7 mm) 3/4' NPT** WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw Assembly 4 - Bulb 7/16' - / 2-1/4 (11,1 mm) A t— _____ N (57,2 mm) NOMINAL i 3 - Sealing 6 - Deflector * * Temperature rating is MAKE-IN indicated on Deflector. 2-3/16".1-9/16' I \ (55,6mm) 1 (39,7 mm) 5 ** Pipe thread connections 6 * per ISO 7-1 can be provided on special 1/2 NPT** t WRENCH request. UPRIGHT FLATS PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT WRENCH RECESS (END 'A' USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B' USED FOR 3/4' NPT MODELS) FIGURE 6 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 4 of 10 Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion- resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 gpm/psi½ (40,3 1pm/bar½) K=4.2 gpm/psi½ (60,5 1pm/bar½) K=5.6 gpm/p5i½ (80,6 1pm/bar½) K=8.0 gpm/psi½ (115,2 1pm/bar½) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table D. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8).....................Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.- lbs. (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 6). With ref- erence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 7). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP17I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS i CHROME PLATED POLYESTER*** 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY1231)* Figure 8 135°F (57°C) Orange 1,2,4 Green 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY1231)** Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) Blue RECESSED PENDENT (TY2231)* Figure 10 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY2231)** Figure 11 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES: Listed by underwriters Laboratories. Inc., (UL) as Quick Response Sprinklers. Listed by underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-uL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. "Installed with Style 2011/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 3, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)° Figure 12 135°F (57°C) Orange 1, 2, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) RECESSED PENDENT (TY3231)** Figure 13 135°F (57°C) Orange 1, 2, 3, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) RECESSED PENDENT (TY4231)° Figure 14 135°F (57°C) Orange 1, 2, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) RECESSED PENDENT (TY4231)** Figure 15 135°F (57°C) Orange 1, 2, 3, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C) Orange 1, 2, 4, 5, 6 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue NOTES: Listed by underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers, Listed by underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.1 Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. Installed with Style 10 11/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS I CHROME PLATED I POLYESTER LEAD COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) and 5.6 UPRIGHT (TY3131) 250 PSI (17,2 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing afire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but TABLE C MAXIMUM WORKING PRESSURE have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers -before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. TFPI7I Page 8 of 10 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4 (19,1 mm) (15 9±6,4 mm) 2-1/4 DIA. I 1/4 (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE I FITTING I 1/8 (3,2 mm) MOUNTING 4 SURFACE 1-5/16'_(33,3 mm) I CLOSURE SERIES TY-FRB 13/16' (20,6 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR,1/2 INCH NPT 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4__(19,1mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4' (6,4 mm) SPRINKLER PLATE / FACE OF (57,2 mm) MOUNTING FITTING 1/8" )I1 (3,2 mm) MOUNTING 4 SURFACE SERIES l-l/4'(31,8mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. 1/2±1/8' (73,0 mm) 1/2"(12,7mm) (12,7±3,2 mm) 2-1/4' DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING \%_ SURFACE CLOSURE SERIES (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8K-FACTOR,1/2 INCH NPT 2-7/8' DIA. 1/2±1/8' (73,0 mm) 1/2'(12,7mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4' (6,4 mm) I I FACE OF 57,2 mm MOUNTING SPRINKLER PLATE I FITTING 1/8" / (3,2 mm) MOUNTING SURFACE SERIES 1-1/4'(31 ,8 mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 9 of 10 2-7/8 DIA. 5/8±1/4' (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4 (6,4 mm) I FACE OF (57,2 mm MOUNTING SPRINKLER PLATE / 1/8 FITTING (3,2 mm) MOUNTING SURFACE SERIES 1-1/4'(31,8 mm) t CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON - 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 5/8±1/4" (73,0 mm) - 3/4"(19,1mm) (15,9±6,4 mm) 2-1/4' DIA. I 1/4' (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' 32 mm) , 4 MOUNTING SURFACE CLOSURE SERIES 1-5/16'_(33,3mm) TYFRB 13/16' (20,6 mm) FIGURE 14 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 2-7/8' DIA. - 1/2±1/8" (73,0 mm) 1/2'_(12,7mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) I I / FACE OF _ 2 mm 1 MOUNTING SPRINKLER PLATE I FITTING __ (3,2 mm) I 7 MOUNTING SURFACE SERIES 1-1/4'_(31,8 mm) TCLOSURE TY-FRB 1" (25,4 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT -. 2-7/8" DIA. 1/2±1/8' (73,0 mm) 1/2'(12,7mm) (12 7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" ____ 7 _____ 1-• t \ (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)l TYFRB 1-1/16" (27,0 mm) FIGURE 15 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 1 NATURAL BRASS - PURE WHITE POLYESTER (RAL901O)1 SIGNAL WHITE - POLYESTER (RAL9003) JET BLACK POLYESTER (RAL9005)2 7 LEAD COATED 9 I CHROME PLATED U TFPI7I Page 10 of 10 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (314"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) TY4931* TEMPERATURE RATINGS 135 135-F (57-C) 155 155°F(68°C) 175 175°F(79°C) 200 I 200°F (93°C) 286 I 286-F (141-C) NOTES: Eastern Hemisphere sales only. Available in only 2.8K, 4.21K, and 8.01K, 155F (68CC) and 200F (93CC); requires lead time to manufacture. P/N 57-XXX-X-XXX I SIN SPRINKLER I I FINISH TABLED SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqcn Fire Protection Products Worldwide Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 Lfft)tL.I The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17,2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psil'2 (80,6 LPM/bar1'2) FEBRUARY 2014 -'T1%.,1 ?Z." -•::-.: t'J* Temperature Rating 135-F (57°C) 155° F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 F— 2-7/8" (73,0 mm) DIA. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb 5 - Compression indicated on Deflector. can be provided on special request. Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 I (11,11 mm) NOMINAL MAKE-IN _____ (50,8 mm) 2" I ______ ______ 1-3/8 (50,8 mm) ______ (34,9 mm) WF 1/2" NPT** DEFLECTOR * STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER I FITTING 5/8" (15,9 mm) \ ' J FLUSH 3/8±5/16 (9,5±7,9 mm) MOUNTING/ 1/8 /- SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4' 1/2" (12,7 mm) (7,9±6,4 mm) \ ____________ FLUSH \ J I MOUNTING 1/8" SURFACE \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 PIN*77_XXX_X_XXX I I SPRINKLER TEMPERATURE FINISH -J- RATINGS SIN 1 NATURAL BRASS I 370 I 5.6K UPRIGHT (1/2- NPT) TY313 3 PURE WHITE (RAL9010)** POLYESTER 371 5.6K PENDENT (1/2 NPT) TY323 POLYESTER SIGNAL WHITE (RAL9003) Use suffix "I" for ISO 7-1 connection, 9 CHROME PLATED for example, 77-370-4-175-I - ** Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135-F (57-C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286-F (141-C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont corporation. Fire Protection Products .a Q .2 2 C.) 0) () CL Cl Q_ - 1Ifl {TTViNT5J1L.JW1LE JJiJGO U . 51 i--~ ~' 11, ............. ( .. ,.. ,. fr1i) L a) C . 2 0) Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ____________ Pressure _ lass 250 Class 300 (°F) (°C) psi Class 150P500 bar si bar psi bar -200 to 1500 -28.90 to 65.60 300 20.7 34.5 600 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 5500 287.80 - - 130 9.0 1 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c(Dus APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ Sizes 'A-i" 66-25 mm) Sizes i1/4'2" (32-51 mm) Sizes 21/2.-3" (64-76 mm) (°F) (°C) psi bar psi bar psi bar psi bar -200 to 1500 -28.90 to 65.60 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 200° 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 550° 287.8 - - 300 20.7 1 300 20.7 1 300 20.7 Cl) C., lo.. IE Anvil Class 150/300 Malleable Iron Fittings conform to ASME l B16.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES %' (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) w __ 0 a) -c I- U) I.. a C 0 U 17 A S ull Moose Tube® is a customer focused, Lgrowth oriented manufacturer and - ma rketer of tiihiiIr nrndiirfc where success is based on a commitment - :.• to meeting the customer's perception - of quality. '--•••. ;; : Our strength resides in our people working together to satisfy customers and to promote business growth by • achieving superior financial performance. www.BullMooseTube.com SCHE1• sales@bullmoosetube.com • 800.325.4467 BULL. MOOSE TUBE CDIVIPAISJY 2 Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. r c®us LISTED APPROVED I] NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. t c®us LISTED <1> APPROVED Do4 ONFSA A,,,.,io.,, rfr. NFPA El SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1/41[T660 1442 J - 991 181lb7sJL 2518 61 - L 1-1/2 1.900 1.682 7.76 2.09 16s/ft 3.053 61 T 2 [ '2157 - 627 264Ibs/ff174223 37] 2-1/2 2.875 2.635 4.92 - 3.53 lbs/ft 5.893 30 3.500 354 ThIbs/ft 19 4 4.500 4.260 2.50 5.62 1bs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS -- NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 11/4 1660 1380 100 -27bft2E 2918 1-1/2 - 1.900 1.610 1.00 2.72 lbs/ft -------44 2 'r -2-3 7-5 2067 1.600 ThIbs7ft 1[5114 3O 2 1/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 350 äL 1 7 5Ibs/ff fl iö783 19 J 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com ) Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas D( Masuq6 OH BULL MOOSE TUBE CCMPAI',IV 63017 FireLock® Outlet-I ® zjj ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 114 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com viclAuLic IS REGISTERED TRADEMARK or VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV ( \%tauIic IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1U.3 FireLock® Outlet-I STYLE 922 DIMENSIONS rffl , I , rM.1 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 \4taulicf REV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X taUluC RFV C, 1O2 FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 vIcTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC 1/2 & 3/4 Inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - cuS2O3EX 2551 1 11- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H- 171 E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPAI3 PIPE ROD I WI 5WT.250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1096.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711,00 3905.00 4050 551 5.. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. SpecificAFCOtVproducts are exclusively designed lobe compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, pails or systems not manufactured or sold by .4FCOTV. AFCON shall NOT be liable tinder any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, orate used. 1/08 Not less than 2 nominal width 4(11I2') Not less than 3" nominal thickness (2-112) ). /1 (depth orside / of vertical member) Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. 1/4 8002957 GST 100 1I4x1 25 - 1/4 8003957 GST 200 1/4x2" 1760 (Fir) 25 125 1/48004957 GST 300 1/4x3" 2060 (Fir) 25 125 3/8 8006957 GST.75 1/4x314" 564 )3/4 Ply) 25 125 3/8 8007957 GST 10 1/4 xl' 210 (7/16 OSB) 300 670 (3/4 Ply) 125 II 3/8 8008957 GST 20 1/4x2' 1760 (Fir) 850 1475 25 125 3/88068925 GST 2OSS1/4x2 1760 (Fir) 850 25 125 1 3/8' 8009925 GST 25-380 3/8 x 2-1/2' 2113 (Fir) 1500 25 125 3/8 8010957 GST30 - "----1/-4x3'2060 (Fir)______ 1500 1475 25 125 1 avc k er 3/8" 8069925 GST 30-SS - 1/4X3" 2060 (Fir) 25 125 Part #8113910 3/80925 GST 40 x4 lL4" 2 O Fir) 25 s J 3/8' 8012925 __GST 60 1/4x6' 2230 (Fir) 25 125 - 7. 1/2 813925GST2 114x2 1760 (Fir) — 25 12 1/2" 8014925 GST 2.5-380 3/8x2-1/2 2113 (Fir) 25 125 k' 1/28015925 GST3 1/4x3 2275(Fv) 251 1/2 8016925 GST4 1/4x4' 2180 (Fir) 25 125 1/2 8017925 - GST6 1/4x6 2230 (Fir) 25 #14 SW Red Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 /" x 12 pitch roof. • Reduces installation cost. Allows 17 deflection from vertical. • Made in the U.S.A. 8137 S14-GST 2O 1/4x2" 1257 (Fir) 1050 1475 25 125 3/8' 8141957 SH-GST30 1/4x3 1720 (Fir) 1500 1475 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4 I __ v M -fitIPU1' (a I #14 Blac- k Nut Driver Part # 8113910 Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. Not less than 2' nominal width (1-1/2') up to 3-1/2' pipe; not lens than 3' (2-1/2') nominal width 4" & 5' pipe 4 Minimum 2-1/2' from bottom for I / branch lines. Minimum 3" from bottom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing ships resting on top of stoat beams. J Floor Joist #14 SW Red Nat Driver Part #8114910 1/4" 8018957 SWG 100 1/4x1 622 (Fir)_____________ __ 25 125 1/4 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 TIF 8020957 SWG10 1/4x1 622)Fr) 300 25 3/8 8021957 8073925 SWG 20 SWG 20 SS 1/402" 1/4x2 1725 (Fir) 1725(Fo) 1050 850 25 25 125 125] 3/8" 3/8" 8022925 8023925 SWG 25-380 SWG 30 3/8x-2 2 1/4x3" - - 2249 (Fir) 1884 )Ffr( 1500 25 25 125 125_J Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8'ç 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. H 41l Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. 111 rh - 0 Fog SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.