Loading...
HomeMy WebLinkAbout6955 EL CAMINO REAL; ; FA160023; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160023 6955 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 2150507600 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 5/25/2016 Approved: 6/20/2016 Issued: 6/20/2016 Inspector: Project Title: BANFIELD PET HOSPITAL INSTALL NEW FIRE ALARM SYSTEM TO MOINTOR WATERFLOW AND TAMPERS AND DUCT DETECTORS AND PULL STATION. INSTALL HORN/STROBES THROUGHOUT FOR NOTIFICATION OF OCCUPANTS. SYTEM TO BE AUTOMATIC (SMOKE DETECTORS, SPRINKLERS) FIRE ALARM SSYTEM MIS MONITORED BY CENTRAL STATION VIA CELL COMMUNITCATOR. Applicant: RIVER FIRE & SECURITY INC. 8920 ACTIVITY RD STEJ SAN DIEGO, CA 858-752-6250 Owner: THE VONS COMPANIES INC PLAZA PASEO REAL ASS 1371 OAKLAND BLVD #200 WALNUT CREEK CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 542 0 542 0 Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 14deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information FAD ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. FAI 60023 6955 EL CAMINO REN- SIGNAUNG LISTED IS09( Space Age Electronics, Inc. SPIN 10.400 p91 MOO REG11Sf6ED www.isae.com NFPA ~6MOANY 800.486.1723 Toll Free WHEMEMM Made l!S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, Just Solutions! ED0549 LT10559 Rev.D 1/2 SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector Property Information Certifications and Approvals 16.1 System Installation Conttoctor; Od 5.IJNF ,th]5di. 16.5 Authority .Having Jurisdiction 555 .0550 mc *!05555522000, Mintmvn, Required Documentation (SIG-FUN) nonsnmaos.remd.ssefloc Susaroor,sOvlsn.Om,cssem, mLvvataosvv...flc..m.reeso, Al 1— Iproo b:.mOeemea, scccynvmmcm,vam.].nso.o, lOCceSsc,evmceSscc.,.mvc.ms..etS 55.07,2 II CcmOO.0nn0.0s5s.eens'O E.- .veo.1na LT10644 Rev. I Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! & Farenhyt D SILENT KNIGHT by Honeywell Intelligent Fire Alarm Control Panel / IFP-50 lFP-50 is an inteIIigentanalog/addressable fire control panel (FACP). IFP-50 has a single line circuit (SLC) loop for connecting addressable detectors and modules and has two notification appliance circuits that can be programmed for notification outputs or auxiliary power. lFP-50 also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. IFP-50 supports a variety of other devices that can be added to the system such as RA-100 or RA-1000 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module, and SD or IDP devices. Features Built-in support for up to 50 Sdevices or 50 IDP detectors and 50 IDP modules - Uses standard wire—no shielded or twisted pair required Built-in digital communicator for remote reporting of system activity and system programming Central station reporting by point or by zone Jumpstart® auto-programming Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC • Distributed, intelligent power Built-in synchronization for appliances from AMSECO, Genter®, Faraday, System Sensor®, and Wheelock® Sensor sensitivity settings and day/night sensitivity setting and automatic drift compensation Notification circuits can be configured as 1 Class A (Style Z), 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in annunciator with a backlit 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 24 VDC Two built-in Form C programmable relays rated at 2.5 amps at 24 VDC SLC device locator can be used to locate a single or multiple devices on a SLC loop System automatically performs detector sensitivity test 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Non volatile event history stores up to 1000 events 125 software zones and 125 output groups Agency Listings MEA UL 4V . - I S 429-92-E Vol XVI IFP-50 2.5 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 7 amp hours). Programmable date setting for Daylight Saving Time Compatibility The IFP-50 SLC supports multiple device typer - the same protocol: SD) IDP You cannot mix SD and IDP devices on a FAC However, any combination of addressable de of the same protocol can be used on the lFP- Specifications ctp*1 Physical Dimensions: 12.75Wx 15.2"H x3.4D (36.8 W x 62.9 H x 9.8 D cm) 0 Weight: 11.5 lbs. (5.2 kg) Color: Red P/N 350328 Rev J © 2014 Honeywell International Inc. UM w 0 Z U —J W U, U, C., CD Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Primary AC: 120 VRMS @ 50/60 Hz, 2.7A Total Accessory Load: 2.5A @ 27.4 VDC power-limited (Standby Current: 200 m) Alarm Current: 365 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Notification Appliance Circuits Two circuits that can be programmed individually as: Notification Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Auxiliary Power Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Indicator Lights Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced Trouble (Yellow): Flashes when a trouble condition exists; solid when trouble silenced Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listing; CSFM 170-0559: 144; MEA 429-92-E Vol XVI Approved Releasing Solenoid Manufacturer Part Number Rating Asco T8210A107 24 VDC, 2.5A Ordering Information ,I FP-5 Intelligent Fire Alarm Control Panel. SBUS Accessories RA-100 Remote Annunciator. Similar in operation and appearance to FACP annunciator. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. 5496 Intelligent Power Module. 6 amp power module that provides four additional power limited notification appliance circuits. 5824 Serial/Parallel Printer Interface Module. Provides one parallel and one RS-232 serial port for connecting a printer to lFP-50. 5880 LED I/O Module. Provides 40 LED outputs, eight normally open dry contacts inputs and one piezo output. 5865-3 & 5865-4 LED Fire Annunciators. Provides 30 programmable LED outputs and a piezo sounder. 5883 Relay Interface Board. Provides 10 general purpose Form C relays. Used with 5880. SD and IDP Devices See the specification sheets listed below for a complete listing of the SD and IDP devices. 350360 SD Devices data sheet 350361 Intelligent Device Protocol (IDP) Devices data sheet Miscellaneous Accessories 5650/5651 Silent Knight Software Suite. Provides programming, upload/download, and event reporting. Order 5650 for PC parallel port compatibility or 5651 for PC USB port compatibility 5670 Silent Knight Software Suite. Provides facility monitoring RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10' H x 6" D (406 mm W x 254 mm H x 152 mm D) SP-TR Small panel trim ring. Use to flush mount Asco 8210G207 24 VDC, 2.5A the panel. 16.975" H x 14.630" W. D SILENT This document is not intended to be used for installation purposes. We try to keep our IIIII product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical support, please call 800-446-6444. www.farenhyt.com Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0144 Page 1 of 2 CATEGORY: C711§5 -- FIREALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT)SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: Models *lFP50 and *5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: FP-50 5700 (Control Unhs 7628 EOL Resistor 5860/5860R/RA-1000 Annunciator 5897 Power Supply 5496 *Notification Power Expander 5824 Serial/Parallel Interface 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-LIM Line Isolation Module S0505-61B Isolation Base RA-1 00 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZAor EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June__3' 0, 2016) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division El Listing No. 7165-0559:0144 Page 2 of 2 NOTE For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/ResetiRestart period shall not exceed 30 seconds. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires CJi 30,- -2016) Authorized By: JAMES PARSEG!AN, Program Coordinator Fire Engineering Division Farenhyt Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal lDP-Photd IDP-Photo-T and IDP-PhotoR The IDP-Photo'is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lFP-series fire alarm control panels (FACP5). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the IDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RAIOOZ) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed DSILENT KNIGHT by Honeywell 1!UO L MEA tOP-Photo (Base not Included) Installation The lDP-Photand IDP-Photo-T plug into a compatible IDP-series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors Compatibility The IDP-Photo, IDP-Photo-T and lDP-PhotoR are compatible with the following lDP-series detector bases: B21OLP 6" Mounting Base B501 4" Mounting Base B224Bl 6" Isolator Base B224RB 6" Relay Base B200SR 6" Sounder Base The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following FACPs: lFP-2000 I RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 I ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350280 Rev G Copyright © 2015 Honeywell International Inc. Wiring 1012-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical Height: 2.0" (5.0 ) (DP-Phof (Photoelectric Smoke Detecto Diameter: 4.1" (10.4 cm) installed in B501 base IDP-Photo-T Photoelectric Smoke Detector with Thermal (135°F) Electrical lDP-PhotoR Photoelectric smoke detector, remote Operating Voltage: 15-32 VDC test capable, for use with DNR (W) duct SLC Standby and Alarm Current: 300 pA' smoke detector Environmental Accessories Operating Temperature RA100Z Remote LED Annunciator. IDP-Photo: 320 - 120°F (0°C - 49°C) XR213 Detector Removal Tool. A removal and IDP-Photo-T: 320 - 100°F (0°C - 38°C) replacement tool for IDP plug-in Humidity: 10% - 93% non-condensing detectors. Includes the T55-127-000. M02-04-01 Detector Test Magnet. Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F M02-09-00 Test Magnet with Telescoping Handle. (57°C) XP4 Extension Pole for XR213. Extends from Velocity: 0 - 4000 fpm (0 - 20 m/sec) (suitable for 5— 15 ft. installation in ducts) T55-127-000 Detector Removal Head. IDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) BCK-200B Black Detector Kit. For lDP-series nominal detectors. * Unless otherwise noted, specifications apply to IDP-Photo and lDP-Photo-T. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications KNIGHT are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. 7272-0559:0149) Page 1 of 1 CATEGORY: (722-- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHTSECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: Models I DP-PHOTO lDPPHOTOR*, I DP-PHOTO-T, lDP-ACCLIMATE, SK-PHOTO, SK PHOTOR* SK PHOTO T and SK ACCLlMATEphotoelectnc type smoke detectors) Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP- PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 (Listing Expire cJune30, 2-01 9) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Farenhyt Addressable Single Action and Dual Action Pull Stations IDP-Pull-SA & lDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1 .3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. D SILENT KNIGHT by Honeywell Agency Listings MEA 67-02-E Vol. IX For IDP-Pull-DA IDP-Pull-SA IDP-Pull-DA Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with the following FACPs: IFP-2000/RPS-2000 Intelligent Fire Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350286 Rev E © 2010 Honeywell International Inc Class A IN SLC OUT Compatible FACP Wiring IDP-Pull-SA & IDP-Pull-DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin 81-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (NIO) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Operating Current (LED flashing): 300 iA Wire Gauge: Up to 12AWG (3.1 mm2) Environmental Operating Temperature 321 - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Pull-SA Single Action Pull Station IDP-Pull-DA Dual Action Pull Station Accessories BG-TR Optional trim ring. SB-I/O Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to IDP-Pull-SA and IDP-Pull-DA. SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications __________ KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. vw.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0157 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model IDP-PULL-SA manual pull box. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. *These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Farenhyt Addressable Monitor Module IDP-Monitor The IDP-Monitor is an addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The lDP-Monitor acts as an interface to contact devices, such as waterliow switches and pull stations. The lDP-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Support for Class A and Class B wiring Fully supervised Panel controlled status LED that flashes green in normal state and is solid red in alarm Attractive ivory cover plate Rotary address switches for fast installation SEMS screws for easy wiring UL Listed Installation The IDP-Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor(5 PN SMB500) is available from Silent Knight. D SILENT KNIGHT by Honeywell Agency Listings SUL MEA IDP-Monitor Compatibility The IDP-Monitor is compatible with the following FACPs: lFP-2000 I RPS-2000 Intelligent Fire Panel IFP-1000 I ECS Intelligent Fire Panel IFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel Ordering Information IDP-Monitor Monitoring Module Accessories SMB500 4" Square Surface Mount Electrical Box P/N 350288 Rev H Copyright© 2013 Honeywell International Inc. TO NEXT DEVICE FROM PANEL OR PREVIOUS DEVICE ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED DO NOT MIX FIRE ALARM INTIATING SUPERVISORY OR (2 SECURITY DEVICES ON THE SAME MODULE, II 471< EOL RESISTOR ELR-47K MONITOR MODULE 0 fl I.) (+) . G CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY ALL WIRING SHOWN IS SUPERVISEDAND POWER LIMITED INITIATING DEVICE CIRCUIT (IDC) - NFPA STYLE B POWER LIMITED 45OpA MAX @ 11 VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXT FROM PANEL OR DEVICE PREVIOUS DEVICE MON1 MODULE ANY NUMBER OF UL LISTED CONTACT jO pTMODULESTOLSTED CLOSURE DEVICES MAY BE USED, DO NOT MIX _________________ COMPATIBLE FIREALARM INTIATING. SUPERVISORY, OR CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE " 9EOL RESISTOR IS INlERNALAT TERMINALS B & 9 "TT !,i ALL WIRING SHOAN IS SUPERVISED AND PORR LIMITED I INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications 550 pA max @ 24 VDC (one communication every Physical 5 sec with EOL <1K) Height: 4.5" (11.4 cm) 5.5 mA (with LED latched on) Width: 4" (10.2 cm) Depth: 1.25" (3 cm) Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 - 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Standby Current: LED Current: 5.5 mA (with LED latched on) End-of-Line Resistance: 47K Initiating Device Circuit Wiring Resistance: 1,500 fl max SLC Loop Resistance: 40 Q max. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing 400 pA max @ 24 VDC (one communication every 5 sec with 47K EOL) I 1 SILENT This document is not intended to be used for installation purposes. We try to keep our or ____________ product information up-to-date and accurate. We cannot cover all specific applications KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7360-0559:0155 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURlTY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaac@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, lDP-Control-6, SK -Control-6, supervising control module, lDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, lDP-Monitor, IDP-Minimon, lDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, lDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP.RELAYMON..2 *SK.RELAYMON2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and lDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 ,Listing Epires une3O, 2016) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 10:1 71, sl C From Tyco Security Products LETAi cos MIT NOW @W FV@ Affm Qnmm iat®.r 3G technology from DSC! Features That Make a Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IP receiver Automatically switches to 2G (EDGE/GPRS) if 3G service is not available Compatible with control panels that communicate using Contact ID or SlA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via automated telephone activation system (VRU), web-user or mobile interlace provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/11/111/lV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed The 3G401OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-lP/ll/lll/lV/5). The 3G40100F uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SlA (300 baud) format. The 3G401OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 and 2013 Editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up prevision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G401 00F can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G401 00F will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. In instances where the control panel does not support Contact ID or SIA (300 baud), the 3G401OCF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IF linecani of the monitoring station receiver (Sur-Gard® System l-lP/11/11VlV/5). Nnlffi~mffilh c From Tvco Security Products Activating & Initializing the Unit Activating and initializing the 3G40100F can be done using the automated telephone activation system ('JRU), mobile interface or web-user interface provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance 024 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cuffing down on time and cost allocated to maintenance. UL Listing The 3G401OCF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the 3G401OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G401OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G40100F has been approved by the California State Fire Marshal (CS FM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G40100E-USA .......... Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the 3G40100F requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2' x 10" x 3" (290 mm x 254 mm x 75 mm) InputVoltage.............................................................120 VAC Current Draw ........................................ .. ... .200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (00 to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description GS-1 5ANT 15 ft extension antenna (internal use) GS-25ANT 25 ft extension antenna (internal/external use) GS-50ANT ft extension antenna r(internal/externaluse) kiiu 1 CALIFORNIA DEPARTMENT OF FORESTRY& FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-12730161 age 1 of i) CATEGORY: 7300 -- FIRE ALARM CONTROCUNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security ControIs95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnitatycoint.com DESIGN (Model 3G401 00F RF Communicator (GSM GPRS/3G) signaUng device It is intended for) use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 120 V, 50/60 Hz, 0.3 A INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to Iistee's Installation Instruction Manual for details. 06-03-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires) o öm Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTE ' 5i MR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrkertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Listed for ceiling or wall mounting Agency Listings SIGNALiNG (9 4jMEA ON LISTED S401 1 (chimes. horn strobes. S5512 (strobes) APPROVED horns) 3023572 approved MEA45205-E 7125-1853188 (indoor strobes) 7125-1853:188 (horn strobes, chime strobes) 7135-1653:189 (horns, ohrrnms) The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 120124 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply 1Tftft 1 Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range io to 93% non-condensing Strobe Flash Rate i flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/RNR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8-diameter x 2.5-high (173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 diameter x 2.2-high (180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, 6.9-diameter x 0.35-high (175 mm diameter x 9 mm high) TRCW-HS) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSOO5O1 UL Current Draw Data 1; 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 11I1iI1®( tjsi 1I&i. 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Ioiz,j Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. AVDSJ5O1 SpectrAlert Advance Dimensions Dia. r o 2.5 do _ 1 _ U o LLJ Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information pT Ceiling Horn Strobes PC2RW 2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W 2-Wire Horn Strobe, Standard cd, White PC2WH* 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red I.. Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW Strobe, Standard cd, White SCWH Strobe, High cd, White Accessories PC4RH 4-Wire Horn Strobe, High cd, Red BBSC-2 Back Box Skirt, Ceiling, Red PC4W 4-Wire Horn Strobe, Standard cd, White Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- Trim Ring, Ceiling, White HS Notes: * Add -P' to model number for plain housing (no 'FIRE" marking on cover), e.g., P2R-P. t Add '-SP' to model number for "FUEGO" marking on cover, e.g.. P2R-SP. f: "Standard cd" refers to strobes that include 15, 15/75. 30, 75, 95. 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150. 177. and 185 candela settings. 06-1 t'S2Y1 3825 Ohio Avenue • St. Charles, IL 60174 Product spech .. 02012 System Sensor. catons subect to chare withal notice. Visit systemsencor.corrr Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product infolmation, including the latest version of this data sheet. AVDSCO5O1 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150 *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires 'June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R,PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151'F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 'Listing Expires" 'June 30, 2016' Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division