Loading...
HomeMy WebLinkAbout6955 EL CAMINO REAL; ; AS160074; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160074 6955 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 2150507600 Lot #: 0 Reference No.: Status: ISSUED Applied 3/28/2016 Approved: 4/7/2016 Issued: 4/7/2016 PC #: Inspector: Project Title: BANFIELD PET HOSPITAL TI. RELOCATE AND ADD NEW SPRINKLERS BELOW T-BAR/HARDLID CEILINGS AN TO ACCOMMODATE FOR NEW WALL AND CEILING LAYOUT Applicant: COSCO FIRE PROTECTION 4990 GREEN CRAIG LN SAN DIEGO, CA 858-444-2000 Owner: THE VONS COMPANIES INC PLAZA PASEO REAL ASS 1371 OAKLAND BLVD #200 WALNUT CREEK CA Fees ($) Add'I Fees ($) j Total ($) Balance ($) 303 0 303 0 San Diego Branch Office .***so* I cosco 4990 Greencraig Lane . I...... San Diego, CA 92123 se es . (858) 44 Fire Protection 4-2000 fax: 444-2056 CA Lie.: C-16 #577621 www.coscoflre.com MATERIAL SUBMITTAL Date: 3-24-16 BANFIELD PET HOSPITAL 695 5 EL CAMINO REAL SUITE B 10 1- 103 CARLSBAD, CA 92009 JOB # 10.CD_5679 All material submitted, may be substituted r r' r p by material of equal performance & design, & shall be deemed acceptable by purchaser. AS1 60074 Submitted by: J. ARVIZU 6955 EL CAMINO REAL Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle October 9, 2009 Sprinkler 11 MICROMATIC® AND MicromaticHP® STANDARD NJIKJNG* RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.c o m DESCRIPTION Viking Micromatic® and MicromaticHP® Standard Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K- Factors to meet design requirements. The special Polyester and Teflon® coat- ings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page hr. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, and 2016 NYC Approved: MEA 89-92-E, Volumes 3 and 12 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060055, G4980001, G4980003, G4980004, G4980006, and G4980008 LPC Approved: Ref. No. 096e/06 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40137, 0 7 8 6 - CPD-40142, 0786-CPD-40177, and 0786-CPD40182 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Charts on pages lIt and 11 u and Design Criteria on page liv for cULus and FM approval requirements th a t must be followed. TECHNICAL DATA Specifications: Available since 1997. Minimum Operating Pressure: 7 psi (0.5 bar)* Viking Technical Data may be found on Maximum Working Pressure: Sprinklers VK021 and VK124 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi http://www.vikinggroupinc.com. (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- The Web site may include a more recent sure (HP) sprinklers can be identified by locating "250" stamped on edition of this Technical Data Page. the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 10138 and 10193. Copper UNS-C19500 for Sprinklers 10141, 10169, 10174, 10220, 10233, and 12106. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09995, 10191, 10192, 10218, and 10219): Brass UNS-C36000 Form No. F'080106' Replaces page llq-v, dated Mrh .7 2008. (Minimum operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Updated FM Approval for Sprinklers VK100 and VK145.) Sprinkler hr October 9, 2009 MICROMATIC® AND MicromaticHP® STANDARD [sJ I VJ IS1GI l:II[• RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09993 and 09995: Brass UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-530400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-NV, Black Polyester = M-/B, and Black Teflon® = N, Wax Coated = C, Wax Over Polyester = V-AN Temperature Suffix (°F/°C): 135°/68° =A, 155°/68° = B, 175°/790 = D, 2000/93° = E, 212°/1000 = M, 2860/141° = G, 3600/182° = H, 500°/2600 = L, OPEN = Z (Teflon® only). For example, sprinkler VK100 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 10138AB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the 'Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) Wrench for wax-coated sprinklers: Part No. 13577W/B** (available since 2006) **A ½" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 197 1) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. 11 October 9, 2009 Sprinkler us MICROMATIC® AND I MicromaticHP® STANDARD I S "jII(IFs1c RESPONSE UPRIGHT AND I CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 OF (57 0C) 100 OF (38 °C) Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green Intermediate 212 OF (100 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Extra High 360 °F (182 °C) 300 OF (149 °C) Mauve Ultra High' 500 OF (260 °C) 465 OF (240 °C) Black Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 135 OF (57 00) Off-White Wax 155 OF (68 °C) Lt. Brown Wax 175 OF (79 °C) Brown Wax 200 OF (93 00) Brown Wax 212 OF (100 °C) Dk. Brown Wax6 286 OF (141 °C) Dk. Brown Wax6 Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 00) Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages lit. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. Wax Over Polyester is unavailable for Sprinklers VK021 and VK124. 6 Wax melting point is 170 0F (76 °C) for 212 °F (100 °C) and 286 °F (141 00) temperature rated sprinklers. Protective Sprinkler Wrench 1;; Cap Flat OEM C==0696=(0) Figure 1: Standard Sprinkler Wrench 10896W/B S Sprinkler lit October 9, 2009 MICROMATIC® AND I MicromaticHP® STANDARD I '%rJ *1WNG4 RESPONSE UPRIGHT AND I CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: t e c h s v c s v i k i n g c o r p . c o m !IN;N0m1 Overall Listings and Approvals' ad Size Part K-Factor Length (Refer also to Design Criteria on page liv.) Number' NPTL BSP U.S. Imetric2 Inches 1mm cULus4 FM I NYC6 I VdS LPCB I ((101 •ii jpright-Standard_Orifice 10138 VK100I 1/2" 15 mm 80.6 12-3/16 56 Bi, 05, E7, F4 A2, C6, E7, F2, H5 10233 VK1451 1/2" Iijflfl1l.. 80.6 12-3/16 56 -- 03, E7, F2 LA2 -- B2 1B2,D5 B2 10174 VK145 I -- 115 mml 5.6 80.6 12-3/161 56 1 A2, D3, F2 -- -- 10193 VK100I -- j mml 5.6 80.6 12-3/161 56 1 81, D5, E7 F4 A2, 03, F2, H5 81, 05, E7 -- - _UPrihtLare Orifice 10220 VK200 VK200I 1/2" 115 mml 8.0 115.2 125/16 23/8 60 B1 05 E7 F4 B2 06 F2 81 D5 1 82 G4 G4 10141 3/4" 1ö 115.2 B1 _ 05, E7: F4 B2, D6: F2 __________ Bi, D5, E71[] G4 G4 10169 vK200I -- 120 mml 8.0 115.2 1 2-5/16.1 59 Bi, D5, E7 B2, 06, F2 -- j -- G4 I G4 Upright -Small Orifice 10218 40.3 2-3/16156 B1, 05, E7 [ D4, 06 -- -- 10219 VKOO2 1/2" 15 mml 42 60.0 2-3/16 56 Bi, D5, E7 -- -- 10191 VK002 -- 15 mmt 60.0 2-3/16t56 B1, 05, E7 -- -- —fT 10192 VK001 -- 15mm12.8 40.3 2-3/161 56 Bi, 05, E7 04, D6 -- -- -- 10176 VK002 -- 10 mm] 4.2 60.0 2-3/16 56 -- -- -- 82 B2,D5 G2 Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice 09993 1VK1241 1/2" 115 mml 5.6 I 80.6 I 2-1/4 I 58 I BI, F5 I -- Upright-Small Orifice" 099959 IVK021 11/2" 115 mml 2.8 I 40.3 I 2-1/4 I 58 I B1 1 -- I -- -- I -- I -- -- Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), 212°F Approved Finishes (100 °C), 286 OF (141 °C), and 360 OF (182 °C) 1 - Brass, Chrome-Enloy', White Polyester', Black Polyester5, and Black OF °C), OF °C), OF °C), OF °C), OF B - 135 (57 155 (68 175 (79 200 (93 286 Teflon 5 (141 °C), and 360 OF (182 °C) 2 - Brass, Chrome-EnIoy, White Polyester, and Black Polyester OF °C), OF °C), OF °C), 200 OF °C), C - 135 (57 155 (68 175 (79 (93 and 3-White Polyester and Wax-Coated Brass (corrosion resistant) OF °C) 212 (100 4 - Brass and Chrome-Enloy® OF °C), OF °C), OF °C) D - 135 OF (57 °C), 155 (68 175 (79 and 200 (93 5-Wax-Coated Brass and Wax over Polyester' OF °C) E - 286 (141 6 - Wax-Coated Brass (corrosion resistant) ° F - 500 OF (260 C)7 G - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 OF (141 °C), and 7 -200 OF (93 °C) High-Temperature Wax Coating (corrosion resistant); 360°F (182 °C) maximum ambient temperature allowed at ceiling = 150 OF (65 °C) H - 155°F(68°C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor s h o w n b y 1 0 . 0 . 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any addition a l a p p r o v a l s . Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 12. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating t e m p e r a t u r e s a b o v e 300 OF (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (14 9 ° C ) , the response time of the Ultra-High temperature rated sprinkler may be severely retarded. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hy d r a u l i c a l l y c a l c u l a t e d wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is co r r o s i o n r e s i s t a n t o r internally galvanized. The sprinkler orifice is bushed. io( ( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40137, 0786-CPD-40177, 0832-CPD-2001, a n d 0 8 3 2 - C P D - 2 0 0 3 . 11 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. S 16 October 9, 2009 Sprinkler 11 MICROMATIC® AND I MicromaticHP® STANDARD I W*j RESPONSE UPRIGHT AND I CON VENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-3845464 Fax: 269.818-1680 Email: techsvcs©vikingcorp.c o m e Id Size Nominal Overall Length Listings and Approvals' I I Part K-Factor (Refer also to Design Criteria on page liv.) Number' NPT I BSP I U.S. I metri C I Inches I mm cULus4 I FM NYC7 VdS I LPCB CE I Conventional-Standard Orifice 10227 1 VK118 1/2" 115 mm 1 5.6 1 80.6 1 2-3/16 I 56 1 Al, B4, C5 -- A2 A2, 84 A28 I D2'° 101726 I VK118 I -- 115 mm I 5.6 80.6 I 2-3/16 I 56 I Al, B4, C5 -- j Al, B4, C51 -- -- I A2, B4 I -- I -- Conventinrial -La rqe Orifice 10228 I VK120 I 3/4" 120 mm I 8.0 I 115.2 I 2-5/16 59 I Al, 134, C5 I -- 'Al, B4, C51 -- I A2, B4 I D38 I D210 101686 I VK120 -- 20 mm 1 8.0 I 115.2 I 2-5/16 59 Al, B4, C5 I -- I -- -- I A2, B4 I D38 D31° 12106 VK120 I 3/4" 20 mm 8.0 I 115.2 I 2-5/16 59 -- I -- I -- I A2 I -- Approved Temperature Ratings Approved Finishes A - 135 °F (57 °C), 155 ¶ (68 °C), 175 °F (79 CC), 200 °F (93 °C), 286 °F - Brass, Chrome-Enloy®, White Polyester', Black Polyester', and Black (141 CC), and 360 °F (182 °C) Teflon®5 B - 135 °F (57 °C), 155 °F (68 °C), 175 ¶(79 CC), and 200 ¶ (93 °C) 2 - Brass, Chrome-Enloy®, White Polyester, and Black Polyester C - 286 °F (141 °C) - Brass and Chrome-Enloy® D - 155 °F (68 CC), 175 ¶ (79 CC), 200 °F (93 CC), 286 °F (141 CC), 4 - Wax-Coated Brass and Wax over Polyester5 °F and 360 °F (182 °C) - 200 (93 C) High-Temperature Wax Coating (corrosion resistant); maxi- mum ambient temperature allowed at ceiling = 150 °F (65 C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10 . 0 . This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Sprinklers 10168 and 10172 are available on special order. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 3. 8 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40142 and 0786-CPD-40182. 10 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1008. 0 Step 1: Carefully slide the wrench sideways around the deflector, ensuring engagement with the sprinkler wrench flats. Wax Coated _/ Upright Sprinkler Sprinkler Wrench 13577W/B* must be used f installing w coated sprin Sprinkler liv October 9, 2009 MICROMATIC® AND I MicromaticHP® STANDARD '\IlIH(AIIS1G RESPONSE UPRIGHT AND I CONVENTIONAL SPRINKLEREQ The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvc s © v i k i n g c o r p . c o m cULus Listing Requirements: Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers are cULus Listed as i n d i c a t e d i n t h e A p p r o v a l C h a r t s f o r installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (co n v e n t i o n a l ) s p r i n k l e r s . Designed for use in Light, Ordinary, and Extra Hazard occupancies. (Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinkler s m a y b e i n s t a l l e d o n h y d r a u l i c a l l y calculated dry pipe systems where piping is corrosion resistant or internally galvanized.) The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followe d . F o r c o n v e n t i o n a l s p r i n k l e r s , r e f e r to the installation guidelines for old style (conventional) sprinklers. FM Aooroval Requirements: Micromatic® and MicromaticHPO Standard Response Upright Sprinklers are FM Approved as indicated in Approval Ch a r t 1 f o r i n s t a l l a t i o n i n a c c o r d a n c e with the latest applicable FM Loss Prevention Data Sheets (includig 2-8N) and Technical Advisory Bulletin s . F M G l o b a l L o s s P r e v e n t i o n D a t a S h e e t s and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply require m e n t s , h y d r a u l i c d e s i g n , c e i l i n g s l o p e and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be inst a l l e d i n a c - cordance with the latest edition of Viking technical data, the appropriate standards of NFP A , F M G l o b a l , L P C B , APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, or d i n a n c e s , a n d standards, whenever applicable. *)IEA 1/2" ratchet is required (not available from Viking), Step 2: Carefully press the wrench downward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W1B for Wax Coated Sprinklers Form No. F_080106 Replaces page ilq-v, dated March 7, 2008. (Minimum operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Updated FM Approval for Sprinklers VK100 and VK145.) 0 March 14, 2008 Sprinkler 41a The Viking Corporation, 210 N Industrial Park Drive, Ha s t i n g s M I 4 9 0 5 8 Telephone: 269-945-9501 Technical Services 877-38 4 - 5 4 6 4 F a x : 2 6 9 - 8 1 8 - 1 6 8 0 E m a i l : t e c h s v c s v i k i n g c o r p . c o m 1 . DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent S p r i n k l e r s a r e s m a l l , thermosensitive, glass-bulb spray sprinklers available in several d i f f e r e n t f i n i s h e s a n d temperature ratings and K-Factors to meet design requirements. T h e s p e c i a l P o l y e s t e r and Teflon® coatings can be used in decorative applications wh e r e c o l o r s a r e d e s i r e d . In addition, these coatings have been investigated for instal l a t i o n i n c o r r o s i v e a t - mospheres and are cULus listed as corrosion resistant as in d i c a t e d i n t h e A p p r o v a l Chart. (Note: FM Global has no approval classification for Teflo n ® a n d P o l y e s t e r c o a t - ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MA 9-92-h, volume i ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G 4 0 6 0 0 5 7 , 0 4 8 8 0 0 4 5 , 0 4 9 3 0 0 3 8 , a n d 0 4 9 8 0 0 2 1 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CP D - 2 0 0 1 , 0 8 3 2 - C P D - 2 0 0 3 , 0 7 8 6 - C P D - 4 0 1 3 0 , a n d 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformit y 0 8 3 2 - M E D - 1 0 0 3 a n d 0 8 3 2 - M E D - 1 0 0 8 NOTE: Other International approval certificates are available u p o n r e q u e s t . Refer to the Approval Chart on page 41d and Design Criteria o n p a g e 4 1 e f o r c U L u s a n d F M a p p r o v a l r e q u i r e m e n t s t h a t m u s t b e followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 122 9 0 a r e r a t e d f o r use with water working pressures ranging from the minim u m 7 p s i (0.5 bar) up to 250 psi (17 bar) for high-pressure systems . H i g h - p r e s - sure (HP) sprinklers can be identified by locating "250" st a m p e d o n the deflector. All other Part Nos. not mentioned above ar e r a t e d t o a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. S Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C195 0 0 f o r S p r i n k l e r s 0 6 6 6 2 B UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for a l l o t h e r S p r i n k l e r s . Bushing (for Sprinklers 06718B, 06720B, and 12290): Bras s U N S - 0 6 0 0 0 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on b o t h s i d e s w i t h T e f l o n T a p e Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C1I000 and Stainle s s S t e e l U N S - S 3 0 4 0 0 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel 06666B, 06765B, and 12104. Copper Form No. F081296 Replaces page 41a-f, dated October 12, 2007. (Added LP C B A p p r o v a l a n d u p d a t e d C E Approval for Sprinkler 06666B, Added Dry System note in a p p r o v a l c h a r t f o r S m a l l O r i f i c e . ) Sprinkler 41b March 14, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 4905 8 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945 - 4 4 9 5 E m a i l : t e c h s v c s v i k i n g c o r p . c o m For Teflon® Coated SDrinklers: Belleville Spring-Exposed, Screw-Nickel P l a t e d , P i p C a p - T e f l o n ® C o a t e d For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the a p p r o p r i a t e s u f f i x f o r t h e s p r i n k l e r f i n - ish and then the appropriate suffix for the temperature rating to the sprinkle r b a s e p a r t n u m b e r . Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black P o l y e s t e r = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/57 = A, 155°/68° = B, 175°/79° = 0, 200°I93° = E, and 2860/1410 = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 ° C t e m p e r a t u r e r a t i n g = P a r t N o . 0 6 6 6 2 B A B Available Finishes And Temperature Ratings: Refer to Table I Accessories: (Also refer to the Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A 1/2' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, c a u s i n g t h e g l a s s t o s h a t t e r , r e l e a s i n g t h e p i p c a p a n d sealing spring assembly. Water flowing through the sprinkler orifice stri k e s t h e s p r i n k l e r d e f l e c t o r , f o r m i n g a u n i f o r m s p r a y p a t t e r n to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. S AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Fo.±s Protective Sprink'er Cap ID: Figure 1: Standard Sprinkler Wrench 10896W/B 0 n March 14, 2008 Sprinkler 41c The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: t e c h s v c s © v i k i n g c o r p . c o m TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS ANDTINISHES 100 °F(38 °) Orange Ordinary 155 °F (68 °C) 100 °F (38 "C) Red Intermediate 175 °F (79 "C) 150 °F (65 °C) Yellow Intermediate 200 "F (93 "C) 150 "F (65 "C) Green High 286 °F (141 "C) 225 "F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes I The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requ i r e m e n t s o f t h e A u t h o r i t y H a v i n g Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving ag e n c i e s i n d i c a t e d o n pages 41d. These tests cannot and do not represent all possible corrosive environments. Prio r t o i n s t a l l a t i o n , v e r i f y t h r o u g h the end-user that the coatings are compatible with or suitable for the proposed environment. F o r a u t o m a t i c s p r i n k l e r s , t h e coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed o n s p r i n k l e r s w i t h Polyester and Teflon® coatings. / I V 11 V Sprinkler Wrench , 12144V/B** for , U installing coated and/or recessed pendent sprinklers Carefully slide the A with protective cops. " wrench sideways ¶ around the protective I cop, ensuring engage- ment with the sprinkler ®*A 1/2 ratchet is required wrench f lots, (not available from Viking). Figure 2: Wrench 12144W/13 for Coated and/or Recessed Pendent Sprinklers a Ll Sprinkler 41d March 14, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techs v c s v i k i n g c o r p . c o m Sprinkler Thread Size Nominal Overall Listings and Approvals3 I_ Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.1 NPT J BSP U.S. metric2 Inches mm cULus4 FM- NYC- VdS LPCB Standard Orifice 06662B VK302 1/2" 115 mm 5.6 80.6 2-1/4" 58 [AIx, B1Y I A3X, B3Y A1X, 131Y A3 { A3X, 133Y C3X, E3Y13 C3X, E3Y15 Large Orifice 06666B VK352 3/4° 20 mm 80 115.2 2-3/8" 60 AIX, B1Y P,2X, B2Y AIX, B1Y -- A3X C313 -- 121 04 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- -- G3 -- -- -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A1X, B1Y - AiX, B1Y A3 -- - -- Small Orifice' 067181310 VK329 1/2" 15 mm 28 40.3 2-3/16" 56 A1X, BIY A2X A1X, BiY -- -- -- -- 06720B1° VK331 1/2" 15 mm 42 60.5 2-1/4" 58 A1X, B1Y -- A1X, B1Y - -- -- -- 06932B VK331 -- 10 mm 42 60.5 2-3/8" 60 -- -- -- A3 -- G214 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria onpage 41e.) Part No' NPT BSP U.S. metric2 Inches mm cULus4 FM NYC" VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 1 58 A1X, B1Y j - AiX -- -- - L - Maximum 250 PSI (17 bar) WWP Small Orifice9 1229010 I VK342 I 1/2" 115 mm 1 2.8 1 40.3 I 2-3/16" 56 AiX, B1Y - I AiX -- -- -- -- Approved Temperature Ratings Approved Escutcheons A- 135 °F (57 "C) 155°F (68 "C) 175°F (79 "C), 200 °F (93 "C) Approved Finishes X - Standard surface-mounted escutcheon or - Brass, Chrome-Enloy®, White Poly- the Viking Microfasr8 Model F-i Adjustable °C), °C), °C)1 B - 135 °F (57 CC), 155°F (68 175°F (79 and 200°F (93 C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F ester 'A,Black Polyester",', and Black Escutcheon 12 (141 °C) Teflon 7 Y - Standard surface-mounted escutcheon or D - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2- Brass and Chrome-Enloy® the Viking Microfast® Model F-i Adjustable (141 °C) 3-Brass, Chrome-Enloy®, White Polyester', Escutcheon 12 or recessed with the Viking : ?: and Black Polyester' Micromatic® Model E-1 or E-2 Recessed Escutcheon °F °C) C - 155 (68 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divid e t h e m e t r i c K - f a c t o r s h o w n b y 1 0 . 0 . This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any a d d i t i o n a l a p p r o v a l s . Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for pro t e c t i o n o f o c c u p a n c i e s d e s c r i b e d i n t h e F a c t o r y Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applie d , w i t h h y d r a u l i c a l l y c a l c u l a t e d w e t s y s t e m s only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is cor r o s i o n r e s i s t a n t o r i n t e r n a l l y g a l v a n i z e d . "The sprinkler orifice is bushed. Accepted for use, City of New York Department of Bu!dirrgs, MEA Number 89-92-E, Vol. 16, "The Viking Microfast Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allo w t h e f u s i b i e e l e m e n t o f t h e sprinkler to be recessed behind the face of the wall or ceiling. 13(( Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 C Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. March 14, 2008 Sprinkler 41e The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsviki n g c o r p . c o m cULus Listing Reguirements: Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for in s t a l l a t i o n i n a c c o r d a n c e w i t h the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Lig h t H a z a r d w h e r e a l l o w e d b y the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Anoroval Reauirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8W) and Tec h n i c a l A d v i s o r y B u l l e t i n s . F M G l o b a l Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minim u m w a t e r s u p p l y r e q u i r e m e n t s , hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distan c e b e l o w t h e c e i l i n g . NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be inst a l l e d i n a c - cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Glo b a l , L P C B , APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordin a n c e s , a n d standards, whenever applicable. CeiUng Opening Size 2-5/16" (58.7 mm) minimum 2-1/8" 2-1/2" (63.5 mm) ma ximum (54 ) 1/2' (15 mm) I 2-1/4" 1-5/8'(58 mm) (41 mm) __ Pendent Sprinkler 06662B (VK302) 1-3/4" (44,5 mm) Installed with o standard 1/8" surfoce- mounted escutcheon. '7 I1) li_i 2 lI II II! 1-1/2" (38.1 mm) (508 Ik ) ,U( Minimum Maximum Installed with a Micr-ofast Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 0 Sprinkler 41f March 14, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com 2-1/8" 1 Ceiling Opening Size: 2-1/8" I (54 mm) 2-5/16" (58,7 mm) minimum (54 mm) 2-1/2" (63,5 mm) maximum 1-3/4" Minimum I 1-1/8" (28,6 mm) (44.5 mm) Maximum Installed with a Micromatic Maclet E-1 Recessed Escutcheon 1-1/8" (286 mm) (50,8 mm) ~22 Minimum Maximum _________ lnstaUed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler. VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE - Approval for Sprinkler 06666B, Added Dry System note in approval chart for Small Orifice.) S SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm iibs./ft.lkg/m CRR Lift 1114 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1% 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.378 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2% 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.628 168.3 6.387 161.8 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm I In. mm In. mm lbs/ft. k/m CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1,68 2,50 1.00 70 1% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1% 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category ViZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C & < APPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E. Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that .outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: fl BLACK E HOT-DIP GALVANIZED WhtITibe thtt ShnP66 r.nr PO578182 1 3!6iL2f'O in o whcat1om I wUom I 1 :1.] DEGREEII NOMINAL SIZE (INCH) l ITEM CODE I MAX. WORKING P.S.I. DIMENSIONS WEIGHT A B EACH PIECE 1 C890033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 21/2 CB90077 300 2.70 2.70 4.75 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIM B'ISION WEIGHT EACH PIECE A 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 t'LT IRONSTRAIGHT411 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A - B 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1.94 2.51 2 CT666 300 2.25 2.25 3.96 2 1/2 CT777 300 2.70 2.70 6.45 NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 1 CB450551 300 1.43 1.43 1.80 2 1 CB450661 300 1 1.68 1.68 2.79 C S C.I. THREADED FITTINGS FITTINGS (I) <> I Dii-kion ofSfar Pipe Prod,cts LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTMA126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME 1316.14. THREADS ARE NPT PER ANSI/ASME 131.20.1. h---- o- S CAST IRON ;i DEG. ITEM MAX. I P.S.I. ELBOW DIMENSIONS WEIGHT EACH PIECE I NOMINAL SIZE (INCH) 1X1/2 CB90031 300 0.64 1X3/4 CB90032 CODE WORKINGC 4411 11.66661 300 0.87 1 1/4X1/2 CB90041 300 0.96 I 1/4X3/4 CB90042 300 1.13 1 1/4X1 CB90043 300 1.16 1 1/2x1 1/2 CB90051 300 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30. 2X1 1/2 C690065 300 2.02 2.16 2.60 Page 38 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 1 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 C.I. THREADED FITTINGS S FITTINGS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 - B - A I CAST IRON NOMINAL SIZE (INCH) I ITEMl CODE 4 MAX. WORKING P.S.I. IM IONS I WEIGHT' EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1 1.65 1.80 2.40 2X1 CX063 300 1 1.73 2.02 2.75 NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIM BJSIONS WEIGHT EACH PIECE A B C 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 113-0 IXII2XI CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 IXiXi 114 CT334 300 1.67 1.67 1 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1(4X1 X1(2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X3/4 CT432 300 1.45 1.38 1 1/4X1X1 CT433 1.501 300 1.58 1/4X1X1 1/4 CT434 300 175 1.67 1.80 1 1/4X1X1 1/2 CT435 1.801 300 1.88 1.37R62 1/4X1 1/4X1/2 T441 300 1.34 1.34 1.37 1 1/4X1 1/4X3/4 CT442300 1.45 1.541 1.45 1/4X1 1/4X1CT443 300 1.58 1.58 1.65 1 1/431 1/4X1 1/2 CT445 300 1.88 1.88 .21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 .55 1 1/2XIX1/2 CT531 300 .411 1.41 1.34 V.882.00 1/2X1X3/4 CT532 300 1.37 .651 1.52 1/2X1X1 CT533 300 .651 1.65 1.50 1/2X1X1 1(4 CT534 300 1.82 1.67 1 1/2Xlrn= CT535 300 1.94 To 1.94 2.30 --TT/0M/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 1/2X1 1/4X3/4 CT542 --907-1.52 1.45 1.75 1.72 1 112X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 1 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665, 1 300 2.02 2.02 2.1C 3.72 2x2x2 1/2 CT667 1 300 1 2.60 1 2.60 2.39 J 5.10 Page 39 FireLock' Outlet-I U A WARNING 4- .QO Read and understand all instructions before attempting to install any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in serious personal injury and/or property damage. AwARNiNG 1 Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Failure to follow this instruction could result in serious personal injury and/or property damage. The Style 922 FireLock Outlet-T is designed for direct connection of sprinkler heads, drop nipples, sprigs, drains, gauges, and other outlet products. The Style 922 FireLock Outlet-I is UL Listed and FM Approved up to 300 psi/2068kPa and VdS Approved up to 16 Bar/232 psi at ambient temperatures that are typical for fire protection systems. PRODUCT DATA pI II. Ut II 114 1/12 1 1 '16 1.30 1.83 1.10 3.87 2.56 1.0 32 >' 15 302 33.0 465 27.9 983 65.0 0.45 3/~ 1 346 1.28 1.83 1.10 3.87 256 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3A, 1.52 218 110 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 , 65.0 0.54 1½ ½ 1 1 'A, 1.42 1.95 1.22 4.08 2.56 1.2 40 x 15 30.2 361 495 31.0 103.6 65.0 0.54 34 13/,6 1.40 1.95 1.22 , 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0!103.6 65.0 : 054, 1 1'A, 1.64 2.30 122 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103,6 65.0 0.59 13/16 1.66 2.19 1.46 4.60 1 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 34 1 i4 1.64 2.19 1,46 4.60 2.56 1.4 20 30.2 417 55.6 37.1 . 116.8 65.0 0.64 1 13A, 1.88 2.54 1.46 4.60 2.56 1.5 25 1 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2½ ½ 1~, . 1.91 2.44 1.71 5.40 2.56 1.6 65 15 , 30.2 48.5 62.0 43.4 137.2 65.0 0.73 ~ 1 'A, 1.89 2.44 ' 1.71 5.40 2.56 1.6 20 30.2 48.0 , 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 ' 1.71 5.40 2.56 1.6 25 30.2 . 54.1 70.9 43.4 137.2 65.0 0.73 - /61 mm s ½ PA, 1.91 2.44 1.71 5.50 2.56 1.6 15 - 30.2 . 48.5 62.0 43.4 139.7 65.0 0.73 34 1 1.89 2.44 1.71 5.50 , 2.56 1.6 20 1 30.2 . 48.0 62.0 43.4 139.7 65.0 , 0.73 1 PA, 2.13 2.79 1.71 5.50 2.56 1.7 25 302 ' 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (Optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinkler heads etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). I www.victaulic.com vIcTAULIC IS REGISTERED TRADEMARK OF VICTALLIC COMPANY. © 2034 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA, r6[9 C: Ac - -922 1 [1 C INSTALLATION INSTRUCTIONS FireLock Outlet-I STYLE 922 PIPE PREPARATION NOTICE Victaulic hole cutting tools are recommended for proper hole preparation. Cut a hole on the centerline of the pipe. Refer to table on page 1 for hole requirements. Exaggerated for clarity 2. Ensure that a ½-inch/13-mm area around the hole is clean, smooth, and free from indentations and/or projections that could affect gasket sealing (refer to the sketch above). Remove any burrs and sharp or rough edges from the hole that might affect assem- bly, proper seating of the locating collar, flow from the outlet, or gasket seating. INSTALLATION 1-922 e Housing 2. Insert a bolt into the outlet housing and lower housing, and thread a nut loosely onto the bolt (nut should be flush with end of bolt) to allow for the "swing-over" feature, as shown above. Install the outlet housing onto the pipe by centering the locating collar in the hole. To check for proper engagement, slide the outlet housing back and forth while pushing down. A properly positioned outlet housing can be moved only a small amount in any direction. 3a. Rotate the lower housing around the pipe, while holding the outlet housing in place to make sure the locating collar remains seated properly in the hole. 1. Install the gasket into the gasket pocket, as shown above. Press the gasket along the full circumference to ensure that it fully seats in the gasket pocket. DO NOT LUBRICATE THE GASKET. Insert the other track bolt into the outlet housing and lower housing. Install the nut finger-tight. www.victaulic.com , . .. vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. K 2004 VICTAULIC COMPANY. ALL RIGHTS RE SERVE D. PRINTED IN THE USA. ictaUlic 1-522 2 REVC INSTALLATION INSTRUCTIONS FireLock® Outlet-T STYLE 922 1-922 5. Tighten the nuts evenly to an approximate torque value of 20ft-lbs/27.1-N.m to ensure proper gasket compression. NOTE: To avoid over-tightening the nuts, use a wrench with a maximum length of 8 inches/200mm. DO NOT over-tighten the nuts. 0 The outlet housing, near the gasket, should not make metal-to-metal contact with the pipe. In addition, a small gap is expected between the outlet housing and the lower housing, as shown above. WARNING DO NOT over-tighten the nuts. Over-tightening the nuts can over-compress the gasket and distort the outlet housing and lower housing. Over-tightening does not enhance product per- formance. Failure to follow this instruction could cause product failure, resulting in serious personal injury and/or property damage. www.victaulic.com - vicTAuLic IS A REGISTERED TRADEMARK OF vlcTAuuc COMPANY. © 2004 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV C S / \JictiLikC -D22 3 STYLE 922 I I II Il III II ItlIllIllIlIlIll liii 11111 IlIJIJI WCAS-65GJ LA For complete contact information, visit www.victaulic.com 1.922 3393 REV C Z100922000 UPDATED 3/2004 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2004 VICTAULIC COMPANY, ALL RIGHTS RESERVED. PRINTED IN THE USA. -927 \4taLJkcr Ll IM Not teas than Wood Flooring 2 nominal width Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. ing Wood - - _ Rod Pait Screw Ultimate ULTest Approvals Size uli37- It-Qbs) AaWs 1/4" 8002957 GST 100 1/4 x r 210 (7/16'OSB) 25 125 1/4" 8003957 GST200 1/4x2" 1760 (Fir) - - 25 125 1/4" 8004957 GST 300 1/4x3" 2060 IFir) 25 125 3/8" 8006957 GST.75 1/4x3/4" 564 (3/4" Ply) 25 125 3/8" 8007957 GST 10 114x i 210 (7/16"OSB) 300 25 125 3/8 8008957 GST 2O1/4x2 60 (Fir) 850 1475 25125 3/8 8068925 - GST 1/4x2 1760 (Fe) 850 - 25 125 3/8" 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 #14 Black 3/8 8010957 GST36 1/4x3 2060(Ftr) - 1500 1475 25 125 - Nut Driver - 3/8 8069925 - GST3OSS 1/4n3 Part#8113910 - 8925 180 10 _L25 3/8 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 - 1/2" 8013925 GST2 1/4x2"1760(Fh) 25 125 1/2" 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 L 112 -801 5 U5 GL! 25 1/2' 8016925 GST4 1/4x4" 2180 (Fir) 25 125 -- 1/2 8017925 GST6 1/4x6 _jF)_ 25 125 #14SWRed Nut Driver Part # 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. "Accommodates up to 1/i" x 12 pitch roof. "Reduces installation cost. "Allows 17 deflection from vertical. • Made in the U.S.A. 310 03W 3/8" 8139957 SH-GST 20 1/4x2" 1257 (Fir) 1050 1475 25 125 125 3/8" 8141957 SH-GST3O 1/4x3" 1720 (Fir) 1500 1475 25 125 1 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. instaflation is thriu covivte. Wuiiuviy iequires tile use or the appropriate nut driver for installations. '1 0 ' V For the most up to date information, visit www.sammysuperscrew.com - MADE IN USA #14 Black Nut Driver Part # 8113910 .5 . - - ,•, -'-, . a 8018957 25 12 1/4" 8019957 SWG 200 1/45 2' 1725 (Fir) 25 125 LQ 8020957 SWG 1/_4 x 1 622(F 300 25 125 - 3/8' 8021957 SWG 20 1/40 2' 1725 (Fir) 1050 25 125 fl 3/8 8073925 1/452 )__— iQ #14 SW Red /. 3/8" 8022925 SWG 25-380 3/8 x 2.1/2" 2249 (Fir) 1500 25 125 Nut Driver 3/8" 8023925 SWG 30 1/4 03" 1884 (Fir) ' 25 125 Part #8114910 — S IN Floor Joist Not less than? nominal etdth (1-1/7) up to 3-Il2" pipe not less than 3'(2-1/7) nominal width 4'& 5 pipe I Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bottom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing ships resting on top of steel beams. Product Features No pie-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. 0 En S Insert the appropriate nut driver into a 3/8' or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4' 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel. HHH4I 41 Insert the appropriate nut driver into a 3/8" or 112"po,lable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the fae o the driver comec r contact with the material you are instaving into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. . Fig. 2— Adjustable Band Hanger C®US LISTED Size Range - Size 21/2" thru 6" pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs, Wt./100 21/2 1/2* 53/4 41/4 1/8 600 41 3 1/2k 6 41/8 11/4 600 45 31/2 1/2* 7 /8 51/4 21/8 600 52 4 5/8* 7 /8 5 1/8 1000 59 5 5/8 9 61/8 21/4 1250 97 6 3/4** 9/8 61/2 1/8 1250 139 C OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 9517375599 • FAX: 951737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2 pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed Qfliy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2'. Patent #5,344,108 C(E)US LISTED OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 'I CUSTOMER SERVICE • 800.785.5266 www.tolco.com Component of State of California OSI-IPD Approved Seismic Restraints System -., FIG. 98 Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8' rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Size Range - Secures 3/8" thru 1112' rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish in 100 - All Thread Rod Full Lnnth S Dimensions *Weights - Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.7375599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com