Loading...
HomeMy WebLinkAbout6965 EL CAMINO REAL; 202; FPC2019-0159; PermitJ I 1 iii1 I']4I Ccity of Carlsbad Print Date: 03/30/2022 Permit No: FPC2019-0159 Job Address: 6965 EL CAMINO REAL, #202, CARLSBAD, CA 92009-4102 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2150507500 Track #: Applied: 07/15/2019 Valuation: $106,973.00 Lot #: Issued: 07/22/2019 Occupancy Group: ' Project U: Finaled Close Out: 02/24/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: AUDEO II CHARTER SCHOOL - ADD/RELOCATE SPRINKLERS (16 HEADS) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MATE JORGENSEN 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov San Diego Branch Office cosco 4990 Greencraig Lane San Diego, CA 92123 ,\ ...••... 4-2000 fax: 444-2056 I Fire Protection ('858) 44 CA Lic.: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL Date: 7-12-19 AUDEO II CHARTER SCHOOL 6965 EL CAMINO REAL #202 CARLSBAD, CA JOB # 1O.CD_5930 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. N 0 N 0 c,1 Submitted by: MATT JORGENSEN Los Angeles • San Francisco • Orange • Fresno • San Diego FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response VIP V2703/V2 704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Ai C_ t; _au I ii C 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 I13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. I Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Ei Exaggerated for clarity S Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date S victaulic.com I Sprinklers I FireLock® I K5.6, '/27 I Publication 40.10 40.10 2544 Rev. i Updated 07/2014 0 2014 Victaulic Company. All rights reserved. 1 \%tauljcr victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 • Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Eli Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated El White painted3 El Black painted3 El Custom painted3 El Proprietary Nickel Teflon2 coating3 El VC-2504 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 x 04t -au ijc S victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Approvals/Listings: Model MrrrvvML,LI I IIU V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.1 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Pendent Upright Pendent Recessed Pendent Approved Temperature Ratings F°/C° 1357/57°C 1357/57°C 1557/68T135°F/57°C 135°F/57°C 135°F/57°C 1557/68T 11557/68T 155°F168°C 155°F/68°C 135°F157°C cULus 175°F/79°C 175°F/79°C C °F179°°F/79°°F/79°C 175 C 175 1557/68T175 200°F193°C 200°F/93°C 200°F193°C 200 °F/93°C 200 °F/93°C 175°F179°C 286° Ff141 °C 286°F/141°C 286° Ff141 °C 2861/141T286° Ff141 °C 200°F193°C 360°F/182°C 360°F1182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F157°C 155°F/68°C 155°F/68°C 135°F/57°C i55°F/8°C 155°F168°C 135°F157°C FM 175°F179°C 175°F/79°C 155°F168°C 175°F/79°C ' 175°F/79°C 155°F168°C 200 °F/93°C 200°F193°C 175°F/79°C 200°F/93°C 200°F193°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°Ff57°C 135°Ff57°C 135°Ff57°C ' 135°F/57°C 135°F/57°C 155°Ff68°C 155°Ff68°C 155°F/68°C 155°F/68°C 155°F/68°C 155 135°F/57°C NYCfMEA 62-99-E 175°F/79°C 175°F/79°C 175°Ff79°C 175°F/79°C 1757/79T1757/79T °F/68°C 200°Ff93°C 200°Ff93°C 200°Ff93°C 200°Ff93°C 200°F/93°C 175°Ff79°C 286° Ff141 °C 286° Ff141 °C 200°Ff93°C 360°F/182°C 360°Ff182°C 286°Ff141°C 286°Ff141°C 286°Ff141°C 135°Ff57°C 135°F/57°C 1557/68T135°Ff57°C 1357/57T135°F/57°C 155°Ff68°C 1757/79T155°Ff68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°Ff79°C 175°Ff79°C 175°Ff79°C 155°F/68°C 200°Ff93°C 200°Ff93°C 200°Ff93°C 200°Ff93°C 200°Ff93°C 175°Ff79°C 286°Ff 141°C °C 286'F/1 41 286°Ff 141°C 286°F/141°C 286°Ff141°C 2007/93T 360°Ff182°C 360°Ff182°C 135°F/57°C 155°Ff68°C 135°F/57°C LPCB 175°Ff79°C None None 155°F/68°C None None 200°Ff93°C 175°Ff79°C 286°F/141°C 200°F/93°C 360°F/182'C 135°F/57°C 135°Ff57°C 155°F/68°C 155°Ff68°C 135°Ff57°C 135°F/57°C 135°F/57°C 135°Ff57°C 175°Ff79°C 175°Ff79°C 155°Ff68°C 155°Ff68°C 155°F/68°C 155°F/68°C VNIIPO 200°Ff93°C 200°F/93°C 175°Ff79°C 175°Ff79°C 175°Ff79°C 1757/79-C 286° Ff141 °C 286° Ff141 °C 200°F/93°C 200°Ff93°C 200°F/93°C 200°Ff93°C 360°F/1 82°C 360°Ff182°C 286°Ff141°C 286°F/141°C ZSTZ ZSTX I K-ZSTZ K-ZSTZ CCC 1551168°C 155°Ff68°C None 155°F/68°C 155°Ff68°C None 200°Ff93°C 200°Ff93°C 200°Ff93°C 200°Ff93°C 135°Ff57°C 155°Ff68°C 135°Ff57°C 175°F/79°C 155°F/68°C VdS 200°Ff93°C None None 175°Ff79°C I None None 286° Ff141 °C 200°Ff93°C 360°Ff182°C 286°Ff141°C 135°F/57°C 155°Ff68°C 135°Ff57°C 175°F/79°C 155°F/68°C CE 200°Ff93°C None None 175°Ff79°C None None 2867/141T °C 200°Ff3°C 360°F/182°C 286°Ff141°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon cnly - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 0 201 Victaulic Company. All rights reserved. iictaulic.com 3 xzctaulieC [i S victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: S 2 60 65 Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Tr MinHoIe 1146/ 17mm Typical CeilingTile 916/ 13A6/ 30 mm Finished Surface F-1- 19/1 \ t 43mm 30nm ____ MAX- IMUM RECESS 2'5A67 - 75 mm 5 MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2,s76O mm I Hole /51 2 mm P_ Max 3 24 mm 1f4/ _Hole _____________ _______________________________ 1 7A6 / Ty pical Ceiling-file18mm 37 mm 5A6'/ Finished Surface 24 mm MAXIMUM RECESS 29167 75 mm MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (drawing not to scale) S 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 \Ate heu uisiriouuon rarcerns - irajectory \ \4+ , ., IIIIIIIIIT''i 10' 3.om 8' 2.4m 6' iBm 4' 1.2m 2' CAm 7 psi — • — . •1 8 kPa 15 psi 103 kPa 30 psi 207 kPa uuiuuiuuui• Ru... mu... ii.... ...uu.0 a maui No iuiaauiu urn iuuuuuaum iuuuuuimui 3.0m! 8' 2Am 6' 1.8n1 4' 1.2m 2' 0.6m 0 7 psi •• — 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinkiers I FireLock® I K5.6, '/27 I Fublicaticn 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendant 2' 4' 6' 8' 10' 12' 14' 0.6m 1.2m 1Cm 2.4m 3Cm 3,7M 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory 2' 4' 6' 8' 10' 12 14' 16' 0.6m 1.2m iBm :.4m 3Cm 3.7r 43m 49m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories floor-wetting, and wall-wetting patterns for these specific Victaulic FireLocl- ALtomatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be usec as minimum :;prin.41er spacing rules :or istallation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitationsand area of coverage requireirents. Failure to follow these guidelines could adversely affect the performance of the spmkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway, 40.10 2544 Rev, J Updatec: 07/2014 © 2)14 Vitaulic Company, All rights reserved. victaulic.com 5 '/tauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - °FI°C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 1350F/570C 100°F/380C Orange Ordinary C 155°F/680C 100°F/380C Red Intermediate E 175°F/790C 150°F/650C Yellow Intermediate F 200°F1930C 150°F1650C Green High J 286°F/1410C 2250F8/1070C Blue Extra High 7 K 360°F/1 82°C 300°F/1 49°C Purple - M Open - No Bulb Standard response only. 150/65 if wax coated. V27-2 Recessed V27 Open End V2707,V27O8Pendent V2707, V2708 Recessed Pendent V2703, V2704 Upright [1 A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: I&S 110 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 -1 ilIi, Atauiicr C.I. THREADED FITTINGS FITTINGS NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WHGHT A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 1 2.25 2.25 2.90 21/2 CB90077 300 1 2.70 2.70 1 4.75 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1X1/2 CRC031 300 1.70 0.62 1 X3/4 CRC032 300 1.70 0.80 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WBGIff EACH PIECE - A - B 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 38 * (~~ <S> . LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 ______ NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WBGHT EACH PIECE - A - B 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1.94 2.51 2 CT666 300 2.25 2.25 3.96 21/2 CT777 300 2.70 2.70 6.45 Ww NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE - A - B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 CB45055 300 1.43 1.43 1.80 2 CB45066 300 1.68 1.68 2.79 idLi NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPLOO4 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPLOOS 300 1.56 0.91 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME B16.14. THREADS ARE NPT PERANSI/ASME B1.20.1. C.I. THREADED FITTINGS 0 \15p FITTINGS A Divthrn ofSftPipe Podu C - - (q * <*> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 ts]t' NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMGSISIONS WEIGHT EACH PIECE - A - B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1 1.80 2.40 2X1 CX063 1 300 1 1.73 1 2.02 2.75 itj.IT 1 NOMINAL SIZE (INCH) ITEM CODE _______ MAX. WORKING P.S.I. DIM B1SIONS WBGIff EACH PIECE A B C 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 U 133 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X3/4 CT432 300 1.45 1.37 1.62 1.38 1 114X1 X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 1/4 I44 300 1.75 1.67 1.75 1.80 1 1/4X1 X1 1/2 C 45 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 t4T 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 44 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1I432 C 300 2.10 2.10 1.90 --2-.3Y- 1 1/2X1X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1X314 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 C 53 300 1.82 1.67 1.88 2.00 1 1/2X1X1 112 Co 1535 300 1.94 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 112X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 1 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 1 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 C 64 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 C 65 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 2x2x2 1/2 CT667 300 2.60 1 2.60 1 2.39 1 5.10 Page 39 @ <&> @ S FLP_C_B~ Mechanical-I® Bolted Branch Outlets SEE VICTAUUCUBLIN 10.01 FOR DETAILS STYLES 920 AND 920N 41 Victaulic Mechanical-n Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/-i-66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Para • \4taulic 11.02 1 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved Date www.victaulic.com VICTALILIC IS REGISTERED TRADEMARK or vIcTAuLIc COMPANY. © 2010 vIcTAULIC COMPANY. ALL RIGHTS RESERVED. REV K STYLES 920 AND 920N DIMENSIONS III ISO 1:470.110A 44 IN olf-In 21~01 INI GROOVED OUTLET Provides a direct branch connection at any location where a hole can be cut .in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. FEMALE THREADED OUTLET CARBON STEEL PIPE. HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets Size Style Max.Work Approx. No. ~Pre ssure@~ 'JIiiTTFL.hI. Weight Each lg X 112 (a) a 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 - 41 136 70 1.5 - 3/4 (a) a 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38,1 50 64 - 41 136 70 1.5 1(a) a 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 70 1.4 1 '/4 (a) to 920¼ 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 1 76 1.7 1 1.5 1½ (a) to 920¼ 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2½ 1/2 (a) §a x 920N 500 1.50 2.21 2.74 91.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 - 1/4 (a) §o 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 1 38.1 1(a) §a 920¼ 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38,1 52 70 - 46 143 70 1.4 - 1 1/4 I' (a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 11/2 '('(a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 ½ (a) 76.1 x 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 1 164 81 1.8 3/4 (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 1)a) 920N 300 1.50 2.07 2.75 - 2.25 6.46 3.18 3.8 - 25 2065 38.1 53 70 - 57 164 81 1.7 1 1/4 (a) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 Th Th 1 1/2 (a) a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 1/2 (a) a X 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 3/4 (a) a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 Th 58 156 70 1.6 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 1 1/4 (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 44.5 65 83 90 58 156 Th 1½ (a) to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) fl 2 (a) a 920¼ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 19 89 90 58 172 99 fl 2.1 3½ 2 3< 110N 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 63.5 76 - 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. 1 Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order, § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY, ALL RIGHTS RESERVED. X0 Ac-t-a -U1 I e 11.02 2 REV K STYLES 920 AND 920N DIMENSIONS sftiI GROOVED OUTLET FWe oil, Well 01 LOULD"Jini= I FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x ½/SO x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets Size Style No Max.Work "esswe@l Dimensions I. . I k w TABLE CONTINUED FROM PAGE 2 4 1/2 (a) D 920N 500 1.50 3.03 1 3.56 2.69 7.01 2.75 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 - 3/4 (a) 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 1(a) ° 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 1 73 90 - 68 178 70 1.8 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 1 ¼ (a) #920N 500 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2 (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 1 83 102 1 102 68 178 99 2.3 2.1 21/2 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 761 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 - 2.9 3(a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 1 114 105 68 196 130 3.8 2.9 1¼ )a)D 108.0 x 920N 500 I. 3.08 3.78 2.63 7.64 3.05 5.0 32 3450 44.5 78 96 67 194 78 2.3 1 ½ )a) 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 - 67 1 194 83 1 2.3 1 - 2 (a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 67 194 102 1.9 - 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 1 84 114 1 114 67 194 124 3.1 3.0 ,< 1 ½ (a) t 920 500 2.00 4,03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 1 94 3.4 1 3.4 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 21/2 (a) " 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 761 rnmc 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 _ 3450 69.9 1 95 1 121 80 246 118 3.6 3(a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 1 246 1 135 1 3.8 1 4.0 133.0 x 2 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 50 3450 63.5 95 114 1 81 203 99 3.6 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. \JItaUIIC RFV K 11.02 CARBON STEEL PIPE. HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS In I'll 'a GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Size No. Style ~Max.Work~ Pressure@ Dimensions Approx. Weight Each :. - ii iLJ TABLE CONTINUED FROM PAGE 3 1 1/2 t 139.7 x 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 84 209 83 3.2 - 2 I' 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 - 50 3450 63.5 95 114 - 84 209 99 4.1 6 1 '/4 (a) X 920N 500 1.75 4.43 513 513 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1½ (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) - 3450 112 130 130 96 1 232 83 2.4 23 2 (a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 76.1 mm 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 267 118 3.8 3(a) I 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 1 3450 889 UO 140 130 94 1 267 135 4.5 89 4 (a) to 920 500 4,50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10,1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 159.0 x 1 ½ (a) 920N 500 2.00 4,41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 689 111 130 92 239 99 36 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 1 130 92 239 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 4.5 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 1 100 3450 114.3 96.80 146 - 92 239 159 8.2 TABLE CONTINUED ON PG. 5 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com vIcTAuLIc IS REGISTERED TRADEMARK OF vIcTAULIc COMPANY. © 2010 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. 11.02 4 4tauiicr REV K CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm III,il,l'.tL.J,. Weight Each MI&ID 'L a, J. YJ TABLE CONTINUED FROM PAGE 4 1651 >' 920N 500 1.50 3.88 4.56 379 934 275 - 25 3450 38.1 99 116 - 96 237 70 3.6 - 1 ¼ D 920¼ 500 1,75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 11/2 (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) I' 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 76 3450 69.9 1 110 130 132 92 267 118 3.9 3.4 3 (a) I' 0 920 500 3.50 4,31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 1 140 130 92 267 1 135 4.6 3.8 4(a) ' 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 1 4.8 3.8 8 X 2(a)t 920 500 2,75 5.44 6.19 6.25 4,81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 2½ (a) I 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 - 159 122 316 116 5.3 3 (a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 1 5.7 1 5.3 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 1 15.3 1 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. l Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2310 VICTAULIC COMPANY. ALL RIGHTS RESERVED. -C \.J(taUIiC RFV K 11.n, S CARBON STEEL PIPE- HOLE CUT PRODUCTS 1J..u' Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N C FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C ,K., Values: = Q2 Where: - f,D = Q2 Where: c42 Q = Flow (GPM) - K Q = Flow (m3/h) = Pressure Drop (psi) v AP = Pressure Drop (bar) Q = C x C, Flow Coefficient Q = K x .'i2 K = Flow Coefficient Exaggerated for clarity Equivalent Length of 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K, Values ½ 0.840 11 - 2 - 15 21.3 9.4 3/4 I 1.050 - 16 20 I 26.7 4 - 13.7 1 1.315 21 8 - 25 33.7 1.8 1 1/4 1.660 50 48 32 42.7 5½ 6 42.9 41.1 1 ½ 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 112 104 50 60.3 9 10½ 96 89.1 21/2 2.875 119 150 65 73.0 20 12½ 102 128.5 3.000 76.1 mm 16 - 161 - 76.1 138.1 3 3.500 249 237 80 88.9 14 15 ½ 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. S www.victaulic.com VIcTAuLIC IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. © 2010 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 11.02 6 \4taulicr REV K CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N 11 FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Approval Agency Rated Working Pressures — psi/kPa 21/2-6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2 -4 2.875 - 4.500 Ali DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875 - 4.500 All S 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168,3 2065 2065 2065 1999 1599 2496 8 8. 625 21/2 10,40 400 - - - 145 - 200 219.1 2755 1000 8 8.625 3,4 10 300 - 250 - 145 - 200 219.1 2065 1724 1000 8 8.625 3,4 30, 40 300 - 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4- 87100 - 200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-I and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Stye 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2765mm groovec outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. S www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV K \4taulicr 11.02 7 V Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 4/2010 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 K - 1/4" 8002957 GST 100 1/4 xl" 210 (7/16"OSB) 25 1251 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 3/8" 8007357 GST 10 1/4s 1" 300 25 125 3/8" 8008357 GST 20 1/4x2 1760 (Fir) 850 1475 25 125 3/8 8068925 GST 20-SS 1/4s2" 1760 (Fir) 850 25 125 3/8"8009925 GST 25-3803/8s2-1/2"2113 (Fir)1500 25125 °' 3/8" 8010957 GST 30 1/4x 3" 2060 (Fir) 1500 1475 25 125 3/8"8069925 GST 30-SS1/4 x3_2060 ( Dir_25125 1/2" 8013925 GST2 1/4x2" 1760 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" - 2275 (Fir) 25 125 1 5 " #14 Black Nut Driver Part # 8113910 1• #14 SW Red Nut Driver Part #8114910 p MMYS® FOR WOOD Not less than 2" nominal width 1/ Not less than 3" nominal thickness (2-1/2") (depth or side of vertical member) Wood Double She Ceiling Wood No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. LLO. L I Watch a video demovvfraiiov www.itwbuildex.com) _ . MOr&vAC1vED USA 17 QRi SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 1/4" 8019957 SWG 200 1/4x2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4x 1" 622 (Fir) 300 25 12 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8 8073925 - SWG 2O SS 1/4x2 1725 (Fir) 850 25 125.....J 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG 30 1/4x 3° 1884 (Fir) 25 125 S - #14SWRed _[ Nut Driver Part # 8114910 * May require pre-drilling; consult joist manufacturer. 211111111111 Black Driver 8113910 #14 SH Orange Nut Driver Part #8273910 I No pie-drilling required. Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless drildriver. Saves time from traditional methods. Reduces installation costs. - Manufactured in the U.S.A. Not less than 2" nominal width /_ (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" & 5" pipe I Minimum 2-1/2" from bottom for I (7 branch lines. Minimum 3" from bot- tom for main lines. Exception: This / 7 J requirement shall not apply to 2" or / thicker nailing strips muting on top of / steel beams. Watch a video damonsfrauon a t t= www.itwbulldex.com Eliminates distortion of threaded rod, -Accommodates up to 3%" x 12 pitch roof. Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. £° 3/8" 8139957 SH-GST2O 1/4x2" 1257 (Fir) 1050 1475 r 1903 Dim. Lumber 1500 3/8"" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 45° Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45°off vertical Dim. Lumber * May require pre-drilling; consult joist manufacturer. no 171-7 177-711 25 125 25 125 25 125 Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2' (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUI) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from [ any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with ' a hex socket attachment be used as installation tools. No impact I I tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a ' pilot hole in wood is required. Finish: Pre-Galvanized !J Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the L - product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. ®1'OLCcT C Its CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size W000 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-/ 3/4 (20) _2 /16" (58.1) 1E/32H27.8) 1/16' (30.2) 51/2 (1.67) - /16" (7.9)- 9 (4.1) 24-1 1"(25) 2/" (66.7)1E/16"(33.3) 1/16" (30.2) 6(1.83) /16"(7.9) 9 (4.1) 24 11/4 11/4 (32) 3" (76.2)1'/2" (38.1) 1/16' (30.2) - 61/2 (1.98) /18"(7.9)11 (5.0) - 24-1/2 11/2" (40) 31/4" (82.5) 1/8" (42.3) 1/16" (30.2) 7 (2.13) /16' (7.9) 12 (5.4) 24-2 2" (50) 3 /16" (93.7) - 127/32" (43.6) 1/16' (30.2) 8 )4 - - /16' (7.9) 15 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4" (20mm) thru 2' (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUl). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4 (20mm) thru 2' (40mm). Patent #5,344,108 B- Lin e by Al) dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions Fig. 200-1 to 200-2 II Fig. 200 Fig. 200F Fig. 20021/2 to 200-8 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B311ONF) .Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8(200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications \MN-H-171 E & A-A-I 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel '. VJ materials will be supplied with (2) hex nuts . in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) /8"-16 31/8" (79.4) 2/8 (66j) 11 (5.0) 200-/4 3/4' (20) /8"-16 31/8' (79.4) 21/2' (63.5) 11 (5.0) - 200-1 1" (25) /8"-16 33/8" (85.7) 2/8' (66.7) 12 - (5.5) 200-11/4 11/4' (32) /8'-16 - 33/4" (94.0) 2/8 (13.0) 13 (5.9) 200 1'/2 11/2 (40) 3/8%16 3/8 - (984) - 2/8 (730) 14 (64) / 200-2 2' (50) /8'-16 41/2' (114.3) - - 3" (16.3) 15 - - (6.9) - 200_21/2 21/2' (65) /8-16 5/8' (142.9) 4 /8" (104.7) 27 - (12.3) - 200-3 (75) I8'-16 57/8"(149.1) 4" (101.6) 29 (13.3) Fig 200S 200_31/2 31/2' (90) -. /8"-16 - 7 /8 (187.3) 51/' (133.3) V 200-4 (100) /8"-16 7 /8' (187.3) 5' - (127.0) 35 (16.0) 200-5 5' (125) 1/2 .13 91/8' (231.8) 61/4 (158,7) 66 V (30.2) . 200-6 6" (150) 1/2 -13 101/8" (257.2) 6/4' (111.4) 73 (33.4) 200-8 8" (200) /2-13 131/8" (333.4) - 8/4" (222.2) 136 V (62.3) - All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Lune Fire Protection Solutions 21 by Part No. Threads Recommended load Approx. Wt/100 R. & Size Per Inch Lbs. NN) Lbs. (kg) AIR '/" x 20 240 (1.07) 12 - (5.44) AIR 31g" x '1' 16 730 (3.24) 29 (13.15) AIR 1/2"x 'I' 13 1350 (6.00) 53 - (24.04) AIR 5/8" x '1' 11 2160 (9.60) - 89 (40.37) - - I AIR 3/4" x 'I' 10 3230 (14.37) 123 (5539) - AIR /8" x '1' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. 0 Threaded Accessories E1) i B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: /8'-16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F 1399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish *I f Standard Design Load Thread Size Thread Length TI 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. lkN) B3205-3/8 x 'I' /8'-16 2.1/2 (63.5) - 730 - (3.25) 572 - (2.54) B3205-1/2 X '1' 1/2"_13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 63205-5/8 x U /8°-11 21/2 (63.5) 2160 (9.61) - 1692 (7.52) B3205-3/4 x I /4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-1/8 x 1 7/8'9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. AIR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8"-16 thru 11/2"-6 rod in 10' )3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°c) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. B?Lu ne All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. byhiij 94 Fire Protection Solutions