Loading...
HomeMy WebLinkAbout6981 EL CAMINO REAL; 102; FPC2019-0082; PermitI 1i II :iII']:i ( 111 ity of Carlsbad 0• lI!1ift Print Date: 03/30/2022 Permit No: FPC2019-0082 Job Address: 6981 EL CAMINO REAL, # 102, CARLSBAD, CA 92009-4149 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2150507500 Track #: Applied: 03/27/2019 Valuation: $257,629.29 Lot #: Issued: 04/01/2019 Occupancy Group: Project #: Finaled Close Out: 02/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: BLACK RAIL RESTAURANT AND BAR -FIRE ALARM SPRINKLER MONITORING SYSTEM Applicant: FPContractor: ADVANTAGE SECURITY AND MULTIMEDIA INC ADVANTAGE SECURITY AND MULTIMEDIA INC MIKE CLIFTON 9655 GRANITE RIDGE DR, # STE 200 5519 CLAIREMONT MESA BLVD, # STE 162 SAN DIEGO, CA 92123-2658 SAN DIEGO, CA 92117-2342 (619) 997-7327 (619) 925-1300 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov s-. SYSTE SE Duct Smok Detector. j:I::.1!] d Expand the versatility of the InnovairFief line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHW Mini-Horn, White RA100Z/RA100ZA Remote Annunciator RTS151 Remote Test Station RTS15 1 KEY Remote Test Station with Key RTS2 Mufti-Signaling Accessory AOS Add-On Strobe RTS2-AOS Multi-Signaling Accessory Agency Listings LISTED ®<e> APPROVED 7300-1653:0212 7300-1653:0211 C E S2522 3034401 7135-1653:0196 9080301 Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APAI5I piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with t'tFPP The MHR and MHW SpectrAlerta Advance mini-horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RAIOOZ and RAIOOZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTSI5I and RTSI5I KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151 KEY test station features a multi-colored LED that alternates between steady green and cod. For 2-wire detectors, the LED illuminates red (or alarm. The RTS2 and RTS2.AOS multi-signaling accessories are designed to work with InnovairFiex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push buttj3n switch. They also enable sensitivity measurements using the SENJS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2- AOS model. c Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 10 VA @32 VDC Temperature Range 0°C to 49°C (32°F to 120°F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 930% Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6'H x 2.9"W x .45D Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR (Full Wave Dimensions 4.8f-1 x 2.90iWx 1.4D Rectified) or Regulated 24 VDC or FWR 1 Sounder Current Draw 22 mA IRMS max. at to 17.5 Volts DC Power Requirements Power LED (Green): 14 to 35 VDC, 29 mA RMS max. at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C (32°F to 120°F) Alarm LED (Red): 2.8 to 32 VDC, Humidity Range 10 to 93% non-condensing 12 mA max. Nominal Sounder 3 kHz Total Current: 105 mA max. Frequency Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6'H x 2.9w x 0.45-D Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Voltage Range Conventional System: 3.1 to 32 VDC Dimensions 4.5H x 2.75VV x 1.8"D Intelligent System: 18 to 32 VDC 1 Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6 Hx 2.8w Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8Wx5.3Hx 1.6D For the very latest product specifications and listing information, ------------ please visit the System Sensor Web site at www.systemsensor.com. C. L±JLJ RTS151 UL S401 1 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS 3825 Ohio Avenue • St. Charles, IL 60174 ©o13s.sem .TFEM f Sensor. Phone. 800-SENSOR2 • Fax: 630-377-6495 PrOdUCtSpecdiCahOflsOJbjcttOch9eWthteitfleotSVStterr5e5sO(.Cten For current product information. including the latest version of this data sheet. www.systemsensor.com HVDS20202 • 8/13 POTTER AFC-50 The Symbol of Protection Fire Alarm Control Panel Features 50 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class Am Class B fos SLC, P-Umk arafl'ACs 5Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at I Amp each Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event I Iistory Buffer Optional two line DACT with UD-1000 that can report General, Zone or Point Information Built in iP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information Product includes 5 year warranty. Description The AFC-50 is an analog/addressable fire alarm system with a total system capacity of 50 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The AFC-50 has a 5Amp power supply with two Notification Appliance Circuits (NACs) and two InpuUOutput (II)) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at lAmp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex. AMSECO, System Sensor and Cooper! Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1 000 adds another 10 Amps of power, 2 additional input circuits and the AFC-50 will support up to 31 power supplies. The -.stem will svnchsonixe the strobes system witIn. In addition. the PSN- 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all circuit connections. ®P(srrrD AFC-SO - - NYC Fire Dept. (\ UL Certificate of Approval €26 LISTED 1165-0328:0509 S735 Technical Specifications Dimensions 16"Wx I7"ffx 3 '/"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-1 30 mA Alarm Crurent-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated I Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of lAmp Temperature and 32° to 120° (0°C to 49°C) with a maximum Humidify Range humidity of 93% non-condensing. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REVB • 01/18 PAGE 10F4 (P)POTTER AFC-50 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 50 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD100-PHD Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PADIOO-H[) Analog Fixed (135d-185dF) or Rate-of-Rise Heat Detector (software selectable) PAD lOODuCTR Addressable Duct Smoke Detector with Form C Relay. Addressable Duct Smoke Detector with Form C relay rated at 10a 250/1 20 VAC or 8amps at 30VDC. PADlOO-DUCT Addressable Duct Smoke Detector. PADI00-613 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD I00-113 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PADIOO-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125 VAC. PADI 00-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD1 00-CD Addressable CO gas detector. PAD100-DD Addressable photo electric smoke detector for use in DUCTIDUCTR enclosure. Modules Device Description PAD 100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PADl 00-PSSA Single Action Addressable Pull Station. PADI 00-PSDA Dual Action Addressable Pull Station. PADlOO-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PADI 00-DiM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PADIOO-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125 VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD I 00-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PADIDD-JM isolaterModnJe intofmpts a short v.a the SLC and prevents the short from affecting protected devices on the loop. PADIOO-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PADUth-SM Speaker Modtde provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD I 00-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. For use with the PAD I 00-DUCTR only. PAD I00-0R01 One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125 VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REVB • 01/18 PAGE 2OF4 SPOTTER AFC50 The Symbol of Protection Fire Alarm Control Panel SLC Features The Potter protocol is a digital protocol with a proven design lbr reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options- The system also allows for a dayinight mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release -Red The common buttons include a Silence, Reset. Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The AFC-50 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 32 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD100-SLCE-Analog/Addressable loop expansion module SLCE-127 -Nohmi addressable loop expansion module for retrofit applications. Potter Electric Signal Company, LLC • St. Louis RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available, LED-16(l) —16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 I/Os and a P-Link repeater. This panel is listed in conjunction with the AFC-50 as releasing circuits. CA-6075 - Class A convertor that converts the SLC, NACs and P-Link connection UD-1000 —Ut listed, Dual line telephone alarm communicator DRy-SO - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 -Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 —Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-bOO, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three AFC series panels to share a single reporting technology. AE-2 - Two card expansion cabinet AE-8 -Eight card expansion cabinet AE-14 - Fourteen card expansion cabinet Ethernet/I.P. Connection The AFC-50 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The 1P communicator is listed to report to the UL listed Sur-Gard ifi IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. MO • Phone: 800-325-3936 www.pottersignal.com 8830133-REVB * 01/18 PAGE 3 OF 4 POTTER AFC-50 The Symbol of Protection Fire Alarm Control Panel Dimensions o olt TOP J DEPTH=3.75' 0 0 DOOR= 16.07' BACKBOX= 15.77' DEPTH =3.84' ,0 re LEFT SIDE RIGHT SIDE BOTTOM DWG p593-1 Ordering Information Model I Description Stock No. AFC-50 I Fire Alarm Control Panel 3992752 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830133-REVB • 01/18 PAGE4OF4 (DPOTTER The Symbol of Protection PADI 00-MM Micro Input Module Features M 12 64 0 One Class B contact monitoring input Small size allows mounting in most electrical boxes .• SLC ClassA, Class X& Class B 6" Pigtail wiring connections Uj Product includes a 5 year warranty (n - ®PoTrER PAD 100-MIM (SLC Module) Description The PAD100-MIM is used to monitor the status of an initiating device(s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadvertent shorts and ground faults. The case can be mounted using a single screw. The PADIOO-MIM has a status indicator LED to indicate communication and alarm condition. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The micro input module (PAD100-MIM) is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. Generally the PADlOO-MIM is used to monitor pull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. Technical Specifications Operating Voltage 24.0V Max SLC Standby 2001.A Current ,Max SLC Alarm 200 pA Current IDC Input Circuit Class B Wizing Max Wiring Resistance 100 of IDC Max Wiring !F' Capacitance of IDC EOL Resistor 5.1K Q Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 121 ats Loop Dimensions 1.75" (44.5mm)L x 1.36" (34.5mm)Wx .43" (llmm)D Mounting Options 2-1/2" (64mm) deep single-gang box Shipping Weight 0.3 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830079-REVC • 3/18 PAGE 10F2 (DPOTTER The Symbol v/ Protection PADI 00-MIM Micro Input Module Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PADIOO-MIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Wiring Diagram Fig I FROM FACP OR PREVIOUS - TO NORMALLY OPEN DEVICE AND TO NEXT DEVICE MONITORED DEVICE 5.1K OHM REQUIRED Part #3005013 Ordering Information Model Description Stock No. PAD I00-M[Iv1 Micro Input Module 3992700 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830079-REVC • 3118 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0509 Page 1 of 2 CATEGORY: 7165--FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: bilIwpottersignal.com DESIGN: Models AFC-50, AFC-100 and AFC-1000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. *Model ARC-1 00 fire alarm control unit. Automatic, Manual, waterflow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. System components: PADiOO-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROl One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 1004M (olator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MlM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure Refer to listee's Installation Instruction Manual for details. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *R 2-04-17 9t This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued-. July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0328:0509 Page 2 of 2 MARKING: Listees name, mode( designation, rating and UL raber. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. *Rev 12-04-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recornnTena'aC7n of the itern listed. This listing stToutd not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (DPOTTER The Syffl/]c/cfPrctect/crr Photoelectric Smoke Sensor Featuyes Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 3.71/olfoot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required LED alarm indicator Product includes a 5 year warranty LISTED Description The Photoelectric Smoke Sensor is a listedAnalogAddressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD 100-PD has a sensitivity range of 1.0 to 3.7 % per foot and is IJL The PAD] 00-PD fe.atuies drift compensation and has built in dirty detector warning as well as. The PADlOO-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. I1e total po%tig speed is less thaih five seeos, wtl% xM&T *e UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field w1iing has no open or short circuits. Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 tLA Alarm indicator 1 LED Alarm set-point range 1.0 to 3.7 %Ift 3.6-12 %/m Installation temperature 32to 120°F! 0to49°C range Operating relative 0% to 93% (Non-condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) lOig (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REVC • 3/18 PAGE 10F2 (E)POTTER PAD1 OOPD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD 100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD100-PD will operate even though the LED may not illuminate. Operation The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs Rash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD 100-PD with the PAD 100-4DB or PAD 100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PADIOO-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PADl00-6DB 6" Standard Base 3992732 PAD tOO-lB 6" base with an isolator module included. 3992730 PAD 100-R13 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125 VAC 3992728 PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD 100-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD100-PD Photoelectric Smoke Sensor 13992733 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REVC • 3/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0504 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@poffersignal.com DESIGN: Models PADIOO-PD, PAD100-DD and PAD100-PHD photoelectric smoke detector heads. Model PAD1 00-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models PAD1 00-PD and PAD100-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PAD1 004D13, PAD100-6DB, PAD100-RB, PAD100-SB (CSFM#7300-0328:502) and Model PAD100-lB (CSFM#7300-0328:501). Model PAD1 00-DD is listed as a photoelectric smoke detector head for use with Model PPkD100-IYtJCT(CS i324-O32B:O5O5). Relerto tstee's Installation Instruction Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an enoTsernent oi !ecorrrrnentitrn ol The YeTn Yiet. Ths Ystiuig sttoxAd not be used to verity coTTeck operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other (911-- Date Issued: July 01, 2018 Listfrrg Epiis Jwie 30,2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division StarLing&k Fire. COMMERCIAL FIRE CELLULAR & IP Commercial Fire Alarm Communicators: Sole & Dual Path Cellular &/or IP / Universal full event sole path cellular & dual path cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere For use as primary or backup communications on all 12V-24V control panels and FACP5 that communicate using Contact ID and 4/2 (such as on legacy panels) Reports to any Central Station nationwide, via dial up or IP Communicate critical life and safety alarm reports on cyber-protected multibillion-dollar cellular nationwide reliable networks, Verizon Network Certified or AT&T, for maximum security & liability protection Easy, flexible installation, activation & online account management Cost-saving models and plans for any code requirement. Substantial savings over monthly dedicated landline charges. And, $100 saving incentive for system upgrades from old radios (all makes) and old POTs landlines, as well as new installations UL and NFPA72 Fire Code-Compliant, the StarLink Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest coverage footprint available in Verizon Network Certified5M CDMA or GSM 3/4G models on the AT&T network, as well as mercantile models, all provide the mosteconomical solution and for easy, versatile installation. Safeguard Accounts & Reliability. For applications currently relying upon quickly-disappearing traditional phone lines, StarLink wireless communicators can be used for primary or backup communications, and will not only safeguard the fire alarm reporting transmissions for the future, but provide the end-user monthly savings for each costly FACP-dedicated landline they replace. And, for upgrading older wireless fire alarm communicators on 2G and other phased-out cellular networks, all StarLink Fire radios, offer a $100 tradeup incentive to help defray the cost of the hardware replacement to the advanced state-of-the-art Star-Link model of choice. Flexible Performance & Reporting Options. StarLink Fire provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes and requirements, with supervisory check-ins from 200 seconds, to 5-minutes, to an hour. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www.napcocomnet.com. And, StarLink Fire Communicators are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating \ i and 24V. Flexible in any application, \ e also comes in standard, or Mercantile \n metal housings, with code-compliant vision, with or without using conduit; and hoice of power options, powered by the panel or using its own 120V Power Supply. 5tUnk I •__ _-.-V --- jV---_-•-_ C - V ( Code-compliant standard or mercantile metal models (right and left respectively). - Napco StarLink Universal Fire Alarm Communicators \- Sole Path Cellular and Dual Path Cellular &Ior IP Models venMn NETWORK e Choice of plans (varies by model) - check-ins from 200 CERTIFIED seconds, to 5-rninutesto 1 hour, 'eTizOfl or AT&T Patented Signal Boost1m signal amplification circuit and high-gain performance antenna for longer range and reliability nationwide NFP Money-saving Tradeup incentive credit Bonus: Full High-Speed Napco Panel remote uploading! downloading CtMi1PUANCES: NA72 citions: 2016,2013, 2010,2007; UL 864, 9th Ed., UL161O, UL985, UL1023, NYCFD; CSFM --iarLink Fire Specifications Ordering Information STANDARD MODELS: Durable ABS plastic housing includes three keyhole slots for mounting (for commercial application, aligns with triple gang boxes.) Dimensions: 5-3/8"x 7-718"x 1-7/8" (HxWxD) - Weight 13.5 oz 3 LED Indicators - Green, Signal Strength; Amber- Busy/ Activation; Red-Trouble Patented Signal Boost1m signal amplification circuit and high- gain performance antenna Operating Environment: 0 to 490 C (32-1200F), up to 93% humidity (non-condensing) 12V - 24V Universal FACP Support, auto-current sensing. Support all brands communicating in Contact ID and 4/2 Powered by Panel, Low current draw, 71 mA standby, 200mA transmit MERCANTILE MODELS (similar to above, with): Locking Metal Enclosure with Hinged door & 2 key-slots for wall mounting (LED indicators, inside). Dimensions: 9-5/8"x 11-3/4" x 3-318"D (HxWxD) Weight: 8 lbs (max., power supply models) Electrical Ratings for 120VAC, 60Hz For Models with Power Supply. Input Voltage: 120VAC Nominal Input Current: 400mA maximum Maximum Charging Current 200mA Electrical Ratings for +12V For Models without Power Supply. Input Voltage: 11-1 SVDC (power-limited output from listed control panel) Input Current: 71 mA with peak RF transmission current of 2OnP. Electrical Ratings for the IN 1 Burg/Fire Input: Input Voltage: 9-15VDC Maximum input Current: Up to 2mA from FAACP NAC circuit Electrical Ratings for IN 2 and IN 3: Maximum Loop Voltage: 15VDC Maximum Loop Ctcrt I .2rciP Electrical Ratings for 3 PGM Outputs: Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not active Maximum PGM Sink Current 5OmA mount. Operating Environment 0 to 49°C (32-1200F), up to 93% humidity (non-condensing) 12V - 24V Ucversa( FIC Suct, rsg. Support all brands communicating in Contact ID and 4/2. COMMERCIAL FIRE SOLE PATH CELLULAR & DUAL PATH CELLULAR &/OR IP ("1" MODELS):* SLE-CDMA-FIRE Standard ABS (Red) Fire Sole Path Alarm Communicator, Cellular CDMA, Verizon-Network Certified SLE-CDMAI-FIRE as above, Dual Path Alarm Communicator, Cellular &/or l (primary or backup, selectable) SLECDMA-CFB-PS Commercial Fire Mercantile model in red metal housing, CDMA, Verizon-Network Certified. Direct 1 2OVAC Powered (WI provisions for backup battery/charger). Or, Optional TRF1 2 plug-in transformer may be used, where codes permit SLECDMA-CFB Commercial Fire Mercantile model in red metal housing on CDMA, Verizon-Network Certified Powered directly from control panel Note: Substitute prefix "SLE3/4G-" on any models above for AT&T 3/4G Network ACCESSORIES: SLE-DLEXT Optional, as above, for downloading, extends distance to Napco panel up to 100' TRF12 Optional Plug in AC Transformer, 16.5V/ 20VA (use is subject to local code compliance) SLE-DLCBL Optional High-Speed Napco Panel Up/download cable Also Available: StarLink Intrusion Radios in standard and mercantile versions YE-c6-3l4G Sttd sglasy Radio (Black), GSM 3/4G on AT&T Network powered by panel. SLE-COMA as above, but CDMA communications, Verizon-Network Certified. SLECDMA-CB Commercial Burglary CDMA Radio, Verizon certified, in white metal housing. Powered directly from control pane). SLE3/4G-CB as above, but GSM 314G on AT&T Network. SLE3/4G-CB-TF Commercial Burglary COMA, Verizon Certified in white metal housing with power supply powered by plug-in 16.5V /2OVA transformer & provision for battery. venzg.Cl zotarLink Fi re. NETWORK CERTIFIED COMMERCIAL FIRE CELLULAR & IP 333 BayviewAve., Amityville, NY 11701 USA 1-800-645-9445 • Fax: 1-631-789-9292 NFPX COMPLIANCES: NFPA 72 Editions: 2016,2013,2010,2007; UL 864, 9th Ed., UL1 610, UL985, UL1 023; NYCFD; CSFM *Stank Are are also rated to support lntnisionitturgry alarm reports where applicable. Startink" and Signal aoost are trademarks of VAPCO. Pats. Pending. Specifications subject to change. ©NAPCO. WPC0 SecurityTechnologvs Inc. (NASDAQ:NSSC) A676E 2017. * Verizon and Verizon Network Certified, UL AT&T and other trademarks, are trademarks of their respective companies, and are unaffiliated with NAPCO. p CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL RE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0992:0144 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Napco333 Bayview Avene, Amityville, NY 11701 Contact David Wagner (631) 842-9400 Fax (631) 842-2726 Email: dwagnernapcosecurity.com DESIGN: Models SLE3I4G-CB, SLE3/4G-CB-TF, SLE3/4G-CFB, SLE3/4G-CFB-PS, SLE-CDMA, SLE-CDMA-FIRE, SLE-GSM-314G, SLE-GSM-FIRE, SLECDMA-CB, SLECDMA-CB-TF, SLECDMA-CFB, SLECDMA-CFB-PS, SLE-.LTEV-FIRE SLE-LTEV-8D, *SLELTEV *SLE..LTEVCFBPS *SLELTEVCBTF, *SLELTEVCFB and *SLELTEVCB Communicators. Models SLECDMAI-CFB-PS, SLE3I4Gl-CFB-PS, SLECDMAI-CB-TF, SLE3/4G1-CB-TF, SLECDMAI-CFB, SLE3I4GI-CFB, SLECDMAI-CB, SLE3I4GI-CB, SLE-GSMI-314G, SLE-CDMAI, SLE-GSMI-FIRE and SLE-CDMAI-FIRE Dual Path Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 Vac - SLE3I4G-CB, SLE3/4Gl-CB-TF, SLE3/4G-CFB-PS, SLE3I4Gl-CFB-PS, SLECDMA-CFB-PS, SLECDMAI-CFB-PS, SLECDMA-CB-TF, SLECDMAI-CB-TF, *SLE.LTEVCFBPS *SLELTEVCBTF 10-15 Vdc- SLECDMAI-CB, SLE314G1-CB, SLE-GSMI-314G, SLE-CDMAI, *SLELTEV *SLELTEVBD *SLELTEVCB 10-25 Vdc- SLECDMAI-CFB, SLE3/4Gl-CFB, SLE-GSM I-Fl RE, SLE-CDMAI-FIRE, *SLELTEVFIRE *SLELTEV.CFB 11-15 Vdc- SLE3I4G-CB, SLE-CDMA, SLE-GSM-314G, SLECDMA-CB 11-25 Vdc - SLE3I4G-CFB, SLECDMA-CFB, SLE-CDMA-FlRE, SLE-GSM-FIRE INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev 07-06-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or rcorwriendation of the item listed. This ñirrig should not be used to verify correct ev operational requirements or installation critena. Refer to listee's data sheet, installation instructions and/or other Dale issued: July 01, 2018 Listing Expires ,3we30, 29 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division