HomeMy WebLinkAbout7700 EL CAMINO REAL; ; FPC2016-0015; PermitA L 1A Ali A Fop Loll :I Cäty of C arlsbad tb Print Date: 03/31/2022 Permit No: FPC2016-0015 Job Address: 7700 EL CAMINO REAL, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2161242500 Track #: Applied: 11/18/2016 Valuation: $256,276.00 Lot #: Issued: 12/06/2016 Occupancy Group: Project #: Finaled Close Out: 02/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #; Final Inspection: Project Title: Description: BANK OF AMERICA: FIRE ALARM SYS (NEW) Applicant: CoApplicant: ADVANCED ALARM INC ADVANCED ALARM INC 13128 TELEGRAPH RD DREW DARLING SANTA FE SPRINGS, CA 90670-4022 13128 TELEGRAPH RD (562) 944-2356 SANTA FE SPRINGS, CA 90670-4022 (562) 944-2356 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov pfc zô ( ((S- "We Service All Existing Alarms" Submittal Package for: Bank of America 7700 El Camino Real Carlsbad, CA 92009 New Fire Alarm System FPC20I6..0015 7700 EL CAMINO REAL (562) 944-2356 # Fax (562) 9442715 0 24 HR CENTRAL STATION. 1-(888) 944-4401 State License #AC03808 • Cont. Lic. C-lU #750871 'Commercial' Residential 'Burglary 'Fire • CCTV -Access Farenhyt Intelligent Fire Alarm Control Panel IFP-1 00 IFP-100 is an intelligent analog/addressable fire control panel. The basic 1FF-I 00 system has a single SLC loop and four notification appliance circuits that can be programmed for notification outputs or auxiliary power. IFP-100 also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features, such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. 1FF-1 00 supports a variety of other devices that can be added to the system such as RA-100 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module, and SD or IDP Protocol devices. Features Built-in support for up to127 SD devices or 99 IDP detectors and 99 IDP modules Uses standard wire—no shielded or twisted pair required Built-in digital communicator for remote reporting of system activity and system programming using either SIA or CID formats. Central station reporting by point or by zone Jumpstart® auto-programming Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC Distributed, intelligent power Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® appliances Sensor sensitivity settings and day/night sensitivity setting Automatic drift compensation Notification circuits configurable as 2 Class A (Style Z), 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in annunciator with a backlit 80-character LCD display RS-485 bus provides communication to system accessories Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC SLC device locator can be used to locate a single or multiple devices on a SLC loop System automatically performs detector sensitivity test 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns Built-in RS-232 and USB interface for programming Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Non volatile event history stores up to 1000 events 125 Software zones and 125 output groups Programmable date setting for Daylight Saving Time D SILENT KNIGHT by Honeywell Agency Listings US L IFP-100 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Integrated dead front panel protects operator from exposure to electrical components The FACP enclosure features a Plexiglass® viewing window to protect annunciator Programmable to automatically display oldest event first or display tally of system events Acknowledge function allows operator to keep track of event status Installation The IFP-100 can be surface or flush mounted. Compatibility The IFP-100 SLC supports multiple device types of the same protocol: SD IDP You cannot mix SD and IDP devices on a FACP. See SD Devices data sheet (PN 350360) and IDP Device Protocol Devices data sheet (PN 350361). P/N 350388 Rev K © 2013 Honeywell International Inc. MEA 429-92-E Vol. XIV Specifications Physical Approved Releasing Solenoids Flush Mount Dimensions: 14.5W x 24.75"H x 3.5D Manufacturer Part Number Rating (36.8 W x 62.9 H x 8.73 D cm) Asco T8210A107 24 VDC, 3A Overall Dimensions: 16W x 26.4'H x 4.65"D (40.6 W x 67 H x 11.8 0 cm) Weight: 28 lbs. (12.8 kg) Color: Red Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Primary AC: 120 VRMS @50/60 Hz, 2.5A Total Accessory Load: 6A @ 27.4 VDC power-limited Standby Current: 170 mA Alarm Current: 325 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 18 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Notification Appliance Circuits Four circuits that can be programmed individually as: Notification Circuits: 3A per circuit @ 27.4 VDC, power-limited Auxiliary Power Circuits: 3A per circuit @ 27.4 VDC, power-limited Asco 8210G207 24 VDC, 3 A Ordering Information IFP-100 Intelligent Fire Alarm Control Panel. SBUS Accessories RA-100 Remote Annunciator. Same operation and similar appearance to FACP annunciator. RA-1 000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1 000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. RPS-1000 Intelligent Power Module. 5496 Intelligent Power Module. 5824 Serial/Parallel Printer Interface Module. 5880 LED I/O Module. 5865-3 & 5865-4 LED Fire Annunciators. 5883 Relay Interface Board. SD and IDP Devices See the specification sheets listed below for a complete listing of the SD and IDP devices. Indicator Lights 350360 SD Devices Specification Sheet. Alarm (Red): Flashes when in alarm; solid when alarm silenced 350361 IDP Devices Specification Sheet. Supervisory (Yellow): Flashes when a supervisory condition Miscellaneous Accessories exists; solid when supervisory silenced 5650/5651 Silent Knight Software Suite. Provides Trouble (Yellow): Flashes when a trouble condition exists; solid programming, upload/download, and event when trouble silenced reporting. Silenced (Yellow): Solid when an alarm, trouble or supervisory condition has been silenced but not yet cleared Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7165-0559:0142; MEA 429-92-E Vol. XIV; OSHPD (CA) OSP-0065-1 0 5670 Silent Knight Software Suite. Provides facility monitoring. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SK-SCK Seismic Compliance Kit D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. ID For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, please call 800-446-6444. www.farenhyt.com Made in the U.S.A. Farenhyt Remote Annunciator RA-100 The RA-100 Remote Annunciator can be used to operate and program the Farenhyt Fire Control Panels. The RA-100's keypad and display match the built-in annunciator of the IFP- 100 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters each) Tactile/audible feedback Larger keypad buttons for system Reset and Silence RS-485 interface to panel Can be flush- or surface mounted. Trim ring available for surface mounting. Operation and appearance is identical to lFP-100 built-in annunciator Initiate and end fire drills with a single key press View event history by alarms, supervisories, or troubles Supports simultaneous use by multiple users from up to 12 separate RA-100s on-board piezo sounder audibly indicates alarms, troubles, and supervisories Five Status LEDs for; alarms, supervisory, trouble, silence and AC power indications. UL listed, complies with NFPA 72 CSFM listed MEA listed Wiring lengths up to 6000 ft. from the control panel D SILENT KNIGHT by Honeywell Agency Listings ®MEA RA-100 Installation The RA-100 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-100 is compatible with the following FACPs: IFP-I000ECS Emergency Communication System with Fire Alarm Control Panel IFP-IOOECS Emergency Communication System and Fire Alarm Control Panel ECS-RCU Remote Command Unit IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350389 Rev F Copyright © 2014 Honeywell International Inc. LED Status IndicatorS Large Buttons for System Silence, Reset. Event Acknowledge. and Fire Drill .. 80 Character Display / Review Events Individually by, Ala Supervisories, or Tr( Numeric Keypad Designed Keypad (Hidden when door is closed) (Hidden when door is closed) RA-100 Features Specifications Electrical Operating Voltage: 24 VDC Standby Current: 20 mA Alarm Current: 25 mA Maximum Per lFP-I 000, 1FF-I 000ECS, lFP-I00 & 1FF-I OOECS System: 12 Maximum per lFP-50 System: 8 Wiring Distance: Up to 6,000 feet from control panel (depending on wiring method) Environmental Operating Temperature: 32° F to 120° F (0° C to 49° C) Humidity: 10% - 93% non-condensing Physical Flush Mount: Outside wall: 12.25"W x 11.5"H x 7/8"D (31.1W x 29.2H x 2.2D cm) Inside wall: 9-318"W x 8-3/8"H x 2"D (23.8W x 21.3H x 5.1D cm) Surface Mount (Including Trim Ring) 12.25W x 11.5"H x 3"D (31.1W x 29.2H x 2.2D cm) Ordering Information RA-1 00 LCD Annunciator. Four line LCD annunciator with 20 characters per line. In red cabinet Optional Accessories RA-100TR Surface Mount Trim Ring D SILENT This document is not intended to be used for installation purposes. We try to keep our __ product information up-to-date and accurate. We cannot cover all specific applica or tions KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444 www.farenhyt.com Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0142 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURlTY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaac©honeywell.com DESIGN: Models *5808 *lFP100 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5808, IFP-100 Control Units *01 FP-100BD Motherboard 7628 EOL Resistor 5860/5860R1RA-1000 Annunciator *0lFP100lA IFP-100 User Interface *058631 5808 User Interface 5496 Power Module 5824 Serial/Parallel Interface RPS-1000 Power Expander/Supply 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-ANM Addressable Notification Module SD500-LlM Line Isolation Module SD505-61B Isolation Base SD-500 SDM Smoke Detector Module RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module *122740 *122723E Enclosures RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0142 Page 2 of 2 This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell MEA US L 225-02-E Vol. V 113P-Photo (Base not Included) Installation The lDP-Photo and IDP-Photo-T plug into a compatible IDP-series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors Compatibility The IDP-Photo, lDP-Photo-T and IDP-PhotoR are compatible with the following IDP-series detector bases: B21OLP 6" Mounting Base B501 4" Mounting Base B224Bl 6" Isolator Base B224RB 6" Relay Base B200SR 6" Sounder Base The lDP-Photo, IDP-Photo-T and IDP-PIotoR are compatible with the following FACPs: IFP-2000 I RPS-2000 Intelligent Fire Panel lFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 / ECS Intelligent Fire Panel lFP-100 / ECS Intelligent Fire Panel lFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel Farenhyt Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo, IDP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. lDP-Photo and lDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the lDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA100Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed P/N 350280 Rev G Copyright © 2015 Honeywell International Inc. I Class A Optional Wiring j J Wiring lOP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical IDP-Photo Photoelectric Smoke Detector Height: 2.0" (5.0 cm) IDP-Photo-T Photoelectric Smoke Detector with Diameter: 4.1" (10.4 cm) installed in B501 base Thermal (135°F) Electrical IDP-PhotoR Photoelectric smoke detector, remote Operating Voltage: 15-32 VDC test capable, for use with DNR (W) duct SLC Standby and Alarm Current 300 pA smoke detector Accessories Environmental Operating Temperature RA100Z Remote LED Annunciator. IDP-Photo: 321 - 120°F (0°C - 49°C) XR2B Detector Removal Tool. A removal and IDP-Photo-T: 321 - 100°F (0°C - 38°C) replacement tool for IDP plug-in detectors. Includes the T55-127-000. Humidity: 10% - 93% non-condensing M02-04-01 Detector Test Magnet. Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F M02-09-00 Test Magnet with Telescoping Handle. (57°C) XP-4 Extension Pole for XR2B. Extends from Velocity: 0 —4000 fpm (0 - 20 m/sec) (suitable for 5 15 ft. installation in ducts) T55-127-000 Detector Removal Head. IDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) BCK-200B Black Detector Kit. For IDP-series nominal detectors. * Unless otherwise noted, specifications apply to lOP-Photo and IDP-Photo-T. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications KNIGHT are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ' LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models lDP-PHOTO, lDPPHOTOR*, IDP-PHOTO-T, IDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models lDP-PHOTO and lDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt DSILENT KNIGHT by Honeywell Addressable Single Action and Dual Action Pull Stations IDP-Pull-SA & lDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. Compatibility The lDP-Pull-SA and lDP-Pull-DA are compatible with the following FACPs: IFP-2000 / RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 I ECS Intelligent Fire Panel Agency Listings MEA 67-02-E Vol. IX For IDP-Pull-DA IOP-Pull-SA IDP-Pull-DA IFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350286 Rev G © 2015 Honeywell International Inc / I SL OUT Compatible FACP Class A Wiring: Class B Wiring: Class B Class A Wiring IDP-Pull-SA & IDP-Pull-DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (NIO) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC SLC Standby and Alarm Current 350 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 320 - 120°F (0°C - 4900) Humidity: 10% - 93% non-condensing Ordering Information lDP-Pull-SA Single Action Pull Station lDP-Pull-DA Dual Action Pull Station Accessories BG-TR Optional trim ring. SB-I/O Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to IDP-Pull-SA and lDP-Pull-DA. DSILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0157 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURlTY1985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywelI.com DESIGN: Model IDP-PULL-SA manual pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division Selectable Output Horns, Strobes, and Horn/Strobes SpectrA lert° Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. Features Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela The SpectrAlert Advance se 4es of notification appliances is designed to si-s-p if, installaticce, with features such as plug in desicns, insta -stfee•ica:k -ne535ce5 to ensure correct installation of indi duaL ces'!ces, and 11 feld-e ec:able candela settings for wall and .-eil -. strobes and horn/.;trcbes. Plug-in design Field selectable candela settings on wall and ceiling units: 15, 15/75, When ins12l'ig Acf'ar•:e pocu::5, first attach a universal mounting 30, 75, 95, 110, 115, 135, 150, 177, 185 plate to a four-inch sq'are, four-inch octagon or double-gang Same mounting plate for wall- and ceiling-mount units junc:ion ocx The t'o-vire rnos ring plate attaches to a single-gang -- ,r--------- •- , junc:ionic.x snorting spring on mounting piate ror continuity cuicuc uiur installation Tamper resistant construction Outdoor wall and ceiling products rated from —40°F to 151'F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Next, cor ect the rot cation sopliance circuit wiring to the SEMS term nab a's the mcjr :ing plate. Finally, attach the hrrstrcbe or horn/strobe to the mounting plate by irser:ing the peoiL:t's tab; ih :he mounting plate's grooves.The device v. II 'ctate t.o os tar, ccking the product's pins into the mounting plats Tar device will temporarily hold in place with a catch jntil it 1; securedcith a captured mounting screw. Outdoor products NEMA 4X rated The SpectrAlert Ad'iar,:e series .ncludes outdoor notification Compatible with MDL sync module appl ances. Otdccr s:-obea a"n: hom/strobes (two wire and four wire are available f:c 'call or c€ili'sg, Outdoor horns are available for wall only. All System 3eiSO cud jor products are rated between mincs 4' degrees Fa'tenheit - d 151 degrees Fahrenheit in wet or Agency Listings dry appl:aocns. SIGNALING MEA 7125-1653:188 (horn/strobes, LISTED APPROVED approved ch1-Atr.be5j 7132-1653189 (horns, me,) 54011 3023572 MEA452.05-E 55512 53593 SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-iflch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75,30, 75, 95,110,115,135,150,177,185- Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 41A6 x 411A6 x 21/a-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit, The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. ' 'C ' '. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate I flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7'W x 2.5'D (142 mm Lx 119 mm W x 64 mm D) Horn dimensions 5.61x4.7"Wx 1.3"D (142 mm Lxi 19 mmWx 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 5.91 x 5.0W x 2.2"D (151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1" diameter x 2.25" high (180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5.71 x 5.1 'W x 2.012 (145 mm Lx 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC) 7.1" diameter x 2.0" high (180 mm diameter x 51 mm high) Wall-mount trim ring dimensions (TR-HS, TRW-HS) 5.71 x 4.812'W x 0,3512(146mm Lx 122W mm x 9 D mm) Ceiling-mount trim ring dimensions (TRC-HS, TRCW-HS) 6.9 diameter x 0.35 high (176 mm diameter x 9 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. JJ Current lIDraw Data ULMaxS be tro,çurrentPraw(mARMS) Nwffll 8-17.5 Volts 16-33 Volts 8-17.5Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30° NA NA 4 96 Temporal Low 38 44 44 48 75° NA NA 1,58 153 Non-temporal High 57 56 69 75 95° NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA '202 195 Non-temporal Low 41 44 50 50 115 NA NA 20 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 28 251 185 NA NA 283 258 _________________ .37 , 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 TeipuralHgh 137 147 1C 6 i' 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 1 6-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temooral Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. -. : . ' Listed Candela Candela rating at -40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn Tones and Sound Output Data - 1.TV •i 8-17.5 16-33 24 Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 Settings 7, 8, and 9 are not available on 2-wire horn/strobe. A05-0395.005 SpectrAlert Advance Dimensions —4.7' 6.8 4.7 Dia. i2 5- 5.6" _ '- Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1' 2.25'1 0 '2,~ Dia. 1P 7 Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information -- Wall Horn/Strobes Ceiling Horn/Strobes (contd.) P2R*s 2-wire Horn/Strobe, Standard cd*, Red PC4W 4-wire Horn/Strobe, Standard cd, White 2RH* 2-wire Horn/Strobe, High cd, Red PC4WH 4-wire Horn/Strobe, High cd, White P2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P2W 2-wife Horn/Strobe, Standard cd, White SCRH Strobe, High cd, Red P2WH 2-wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor P4R 4-wire Horn/Strobe, Standard cd, Red SCRHK Strobe, High cd, Red, Outdoor P4RH* 4-wire Horn/Strobe High cd Red SCW S obe Standard cd White P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor SCWHt Strobe, High cd, White P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor Horns P4W 4-wire Horn/Strobe, Standard cd,White HR Horn, Red P4WH 4-wire Horn/Strobe, High cd, White HRK Horn, Red, Outdoor Wall Strobes HW Horn, White SRt Strobe, Standard cd, Red Accessories SRHat Strobe, High cd, Red BBS-2 Back Box Skirt, Wall, Red SRK Strobe, Standard cd, Red, Outdoor BBSW-2 Back Box Skirt, Wall, White SRHK Strobe, High cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red SW* Strobe, Standard cd, White BBSCW-2 Back Box Skirt, Ceiling, White SWH Strobe, High cd, White TR-HS Trim Ring, Wall, Red Ceiling Horn/Strobes TRW-HS Trim Ring, Wall White PC2R 2-wire Horn/Strobe, Standard cd, Red TRC-HS Trim Ring, Ceiling, Red PC2RHa 2-wire Horn/Strobe, High cd, Red TRCW-HS Trim Ring, Ceiling, White PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor Notes: PC2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor Add "-P"to model number for plain housing (no "FIRE" marking on cover), e.g., PC2W vI:r Hcm/Srbc Stodard c ivi ite P2R P t Add "-SP"to model number for "FUECO"marking on cover, e.g., P2R-SP. PC2WH 2-wire Horn/Strobe, High cd, White * Standard cd, refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 PC4R 4-wire Horn/Strobe, Standard cd, Red candela settings. "High cd," refers to strobes that include 135, 150, 177, and 185 PC4RH 4-wire Horn/Strobe, High cd, Red candela settings. PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor All outdoor units ending in "K"include a weatherproof back box. PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor n Add "-R"to model number for weatherproof replacement device (no back box included). 0200 System Sen— TEM 3825 Ohio Avenue St. Charles, IL 60174 Product specifications subject to ch8ange wthout notice msit systemsersoccom for Sys Phone: 800-SENSOR2 Fax: 630-377-6495 data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2R1-I and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -.BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trishlinhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CAST!LLO, Program Coordinator Fire Engineering Division IPGSM-4G IP Internet & GSM (4G/3G/2G) Dual Path Communicator General The IPGSM-4G is a 4G fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel (FACP) that has a built-in dialer. This easy to install, dual path commu- nicator connects directly to the primary and secondary com- munication ports of a Fire panel's Digital Alarm Communicator Transmitter (DACT). It offers three selectable reporting paths which include: (Cellular only), (IP only), or (IP primary/cellular backup). In The event of an off-normal condition, the fire panel sends contact ID formatted information to the IPGSM-4G com- municator panel. The IPGSM-4G then reformats the data into highly encrypted Ethernet packets for transmission to the Alarm-Net receiver via customer-provided Internet/Intranet connection or the GSM network. Alternative communication methods are critical in the market- place due to VoIP (Voice over IP), migration from POTS (Plain Old Telephone Service) and growth of digital radio networks. The IPGSM-40s exclusive dual-path communications solution combines Internet service with GSM for added reliability and an extra level of security. All signals from the IPGSM-4G com- municator panel are delivered to Honeywell's AlarmNet Net- work Control Center, which routes the information to the appropriate central station. The state of the art AlarmNet net- work control center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi- path message delivery. The IPGSM-4G is designed to operate over the most common GSM networks including 2G,3G and 4G. Its multi-GSM plat- form technology automatically chooses the best available cel- lular signal in the area based on signal strength and seamlessly self-adjusts to maintain critical life safety communi- cation. Features Saves the cost of two dedicated phone lines. Dual path communications. Can communicate to central station using Internet or cellular technology. Requires no change to the existing Fire Alarm Control Panel configuration. The IPGSM-4G connects directly to the primary and secondary telephone ports. Multi-GSM platform compatibility for 2G, 3G and 4G. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) GPRS (2G). Works over any type of customer provided Ethernet 10/100 Base network connection (LAN or WAN), DSL modem or cable modem. Data transmits over standard contact-ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit). Supports both dynamic (DHCP) or Public and Private Static IP addressing. Built-In Power Supply module: On board charging circuit design accommodates back-up battery. Includes primary power and battery supervision. Diagnostic LEDs: Signal strength and status indicators. Reliable connection: IP and GSM connection tested every day. QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including when message was received, signal strength, and message path used. 7720P Hand-held programmer for easy setup. Operation When an event occurs, the Fire Alarm Control Panel goes off hook to dial the central station. The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel. The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent on configuration). Easy to Program The IPGSM-4G communicator can be pre-programmed using the 7720P programmer to enter all central-station information. This is saved to the IPGSM-4G communicator panel memory. When the IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the AlarmNet receiver. .For most installations, the only required parameters are: Primary City ID (two digits) obtained from your monitoring station. Primary Central Station ID (two digits) obtained from your monitoring station. Primary Subscriber ID (four digits) obtained from your mon- itoring station. Communication Module's MAC ID, and MAC CRC number located on outside of box, and inside of the module. All of these parameters are assigned by the monitoring station. NOTE: Some assembly is required. See Installation and Setup Guide #800-12454 for full details. Panel Capabilities The IPGSM-4G is compatible with fire panels that use the Contact ID communications format as described in the SIA DC-05 standard. AlarmNet Honeywell's AlarmNet has been the nationwide leader in alarm communications technology since 1986. A reliable alter- native for the transmission of alarm signals, our radio network provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra- structure support. The AlarmNet network consist of redundant hardware servers, hot back-up databases and generators with battery back-up at all locations to ensure continuity of service. Signals from Alarm-Net are transmitted to the central station's receivers using multiple communications paths consisting of the Internet, radio network or toll-free POTS service. Installation Requirements UL COMPLIANCE To meet UL864/NFPA, ensure the following: IPGSM-4G must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72. IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. IPGSM-4G, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be pro- vided with appropriate standby power. IPGSM-4G must use the 7AH battery (not supplied) to pro- vide 24-hour backup capability. Electrical Specifications Transformer: — Primary 120 VAC, 60Hz, 0.5A. — Secondary: 18VDC, 50VA. Battery: — One 12 V 7.0 AH lead-acid battery (not supplied). — Battery charging current: 1 Amp maximum. — Battery discharge current: Standby 230mA, Active 950mA. Cabinet Specifications Dimensions: 14.875" H x 12.75"W x 3.0" D (37.8 cm H x 32.4 cm W x 7.6 cm D). Color: Red. Shipping Specifications Weight: 5.3 lbs. (6.94 kg). Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x 34.9 cm W x 23.9 cm D) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 270C/60 - 80°F. Product Line Information IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- cator Panel. Includes red cabinet with ademco key and lock, wall outlet box, Dialer Capture Module, iGSM Communications Module, antenna & mounting adapter, PowerBoosti power supply, LED display board, transformer, manual, & required screws, cables, etc. GSM-ANT3DB: 3db gain external/remote antenna. 7626-50HC: 50 ft. antenna cable, low loss. 7626-25HC: 25 ft. antenna cable, low loss. WA7626-CA: SNA to N Adapter. 7720P: IPGSM-4G hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. BAT-1270: Battery 12 Volts, 7 AH, sealed. Agency Listings and Approvals The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S789. CSFM: 7300-1645:0199. FDNY: COA #6150. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ©2013 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywell.com www.honeywellpower.com DH-60769:B June 2013 Made in the U.S.A. ISO 000i________________ 15 U.S. Registered Trademark dl I CJ Ob 15 2013 Honeywell International Inc. ENGINEERING aaiireerwure Page 2012 QUALITY SYSTEMS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0199 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com DESIGN: Models 1PGSM-COM, iPGSM-DP, iPGSM-4G and *IGSMCFP4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with separately listed compatible commercial and residential fire alarm control units. *Model IGSMCFP4G is intended for use with specific Honeywell Security control units that employ the ECP bus. Refer to listee's installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. iPGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. *Rev 07-01-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SIGNALING LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 14deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information Z_---7=-_--77— FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. IS0.9001 Space Age Electronics, Inc. lielip—T-5-Im— MOR www.lsae.com NIFPA ~,OMOANY 800.486.1723 Toll Free METMER 508.485.0966 Local / 508.485.4740 Fax Made ISA. Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! property Informotlon Minimum Required Documentation (SIG-FUN) Cortlttcatjons and Appr000ls 16.1 Syoto,,, Instolloton Conyonton 16.5 Antnority Honing Jurisdiction: 050 55 s*1., 5505005 050 015 105551.0505 0155 P50510550010 0.00 .50000 0651005005015500n% SV50p ShOOT 005015,. 00,05005 SNIP 001,010555 0 0105505.,, P15,10505. ISCO,5515001000055005010000100000N1,15.107L2 10. ,Ipoppou.çors.o..o.55k.o. Equipment Information I'0' 0 .d S .Sg.NI50osto, s800s10.,NRo50 Sb,I,s 1001504 05.4.5.1743 oo1U.to LT11044 R111 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. P'SPACE AGE YELECTRONICS, INC Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. El IL I I I USB Storage Interface Requires Standard USB-B Connector 4 Business Card Holder Key Ring Hooks Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED S5U00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc# ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ' LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFX/A and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTIL.L.O, Program Coordinator Fire Engineering Division F PC LOI C - D SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 12-29-2016 Supplemental Pages Attached: 0 1. PROPERTY INFORMATION Name of property: Bank of America - La Costa Address: 7700 El Camino Real Description of property: 2 Story Office Building - Non Sprinklered Name of property representative: Excel Construction Address: 1950 Raymer Ave. Fullerton, CA 92833 Phone: 714-680-9200 Fax: E-mail: ExcelConstruction.biz INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Advanced Alarm, Inc. Address: 13128 Telegraph Rd. Suite H Santa Fe Springs, CA 90670 Phone: 562-944-2356 Fax: 562-944-2715 E-mail: drew@weprotectall.com Service organization: Advanced Alarm, Inc. Address: 13128 Telegraph Rd. Suite H Santa Fe Springs, CA 90670 Phone: 562-944-2356 Fax: 562-944-2715 E-mail: drew@weprotectall.com Testing organization: Advanced Alarm, Inc. - Address: 13128 Telegraph Rd. Suite H Santa FeSprings, CA 90670 Phone: 562-944-2356 Fax: 562-944-2715 E-mail: drew@weprotectall.com Effective date for test and inspection contract: Unknown Monitoring organization: National Monitoring Services Address: 25341 Commercentre Dr. Lake Forest, CA 92630 Phone: 800-662-1711 Fax: N/A E-mail: NIA Account number: LGZ4823 Phone line 1: None Phone line 2: None Means of transmission: Digital Alarm Communicating Transmitter with IPGSM-4G Sole-path Cellular Entity to which alarms are retransmitted: Phone: DOCUMENTATION On-site location of the required record documents and site-specific Maintenance and Operations software: DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system 0 Modification to existing system Permit number: FPC2016-0015 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: Silent Knight Model number: IFP-1 00 4.2 Software and Firmware Firmware revision number: 15 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification N/A Alarm verification set for N/A seconds Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution (p. 1 of 3) SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 Overcurrent protection: Type: Breaker Branch circuit disconnecting means location: Panel B Control panel amps: - Amps: 20 Number: Circuit 35 3 5.1.2 Secondary Power Type of secondary power: Batteries. 17Ah Location, if remote from the plant: N/A Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 5.2 Control Unit Z This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS In alarm mode (minutes): 15 Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line Yes No B 0 Device Power Yes No B 0 Initiating Device N/A N/A N/A N/A Notification Appliance Yes No B 0 Other (specify): N/A N/A N/A N/A REMOTE ANNUNCIATORS Location LCD I Front Lobby R- INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 3 N/A N/A N/A Smoke Detectors 33 Addressable Alarm Photo Duct Smoke Detectors 0 N/A N/A N/A Heat Detectors 0 N/A N/A N/A Gas Detectors 0 N/A N/A N/A Waterfiow Switches 0 N/A N/A N/A Tamper Switches 0 N/A N/A N/A Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p.2 of 3)