Loading...
HomeMy WebLinkAbout2320 FARADAY AVE; ; FPC2016-0010; PermitJ1 :1'I I:1i.]4I 4ity of Carlsbad Print Date: 03/31/2022 Permit No: FPC2016-0010 Job Address: 2320 FARADAY AVE. CARLSBAD, CA 92008-7216 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 11/17/2016 Valuation: $0.00 Lot #: Issued: 12/06/2016 Occupancy Group: Project #: Finaled Close Out: 03/01/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: BUILDING 2320 - INSTALLATION OF CONVENTIONAL FIRE ALARM SYSTEM TO MONITOR SPRINKLER SYSTEM FPContractor: SENTINEL SECURITY SYSTEMS-INACTIVE P0 BOX 300577 ESCONDIDO, CA 92030-0577 (760) 741-0890 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov BUILDING 2320 2330 FARADAY AVENUE CARLSBAD, CA 92008 SPECIFICATION DOCUMENTATION FOR: FIRE ALARM SYSTEM S SENTINEL SECURITY SYSTEMS 1859 S. ESCONDIDO BLVD ESCONDIDO, CA 92025 SUBMITTED BY: ZAK PESCAR 0 PHONE U: 760.741.0890 0 0 I LU > 11/15/2016 (0 < '-I O > C.) LL A - o Ii TABLE OF CONTENTS AES 7706- ULF DATA SHEETS PAGES 1-2 FACP LISTING SHEET PAGES 3 n PHOTOELECTRIC SMOKE DETECTORS MANUEL PULL STATION SERIES INDOOR SELECTABLE- OUTPUT HORNS, STROBES HONEYWELL FIRE ALARM CABLE BUILDING 2320 11/15/2016 DATA SHEETS PAGES 4-5 LISTING SHEET PAGE 6 DATA SHEETS PAGES 7 LISTING SHEET PAGE 8 DATA SHEETS PAGES 9-12 LISTING SHEET PAGE 13 DATA SHEETS PAGES 14-15 LISTING SHEET PAGE 16 0 CORPORATION ass-corp.com Technical Specifications DIMENSIONS 11/2"H x 14-1/4"W x 4314'D 4€.9 cm H x 36,1 cm W x 12.1 cm D) WEIGHT Approximately 17 pounds (8 kilograms), excludes battery CABINET COLOR Red AC POWER INPUT 120VAc 60 Hi 1.0 AMP Integrated Fire Monitoring System 7706-ULF 'The AES 7706-ULF delivers fire alarm signals much faster to the central monitoring station in comparison to existing DACT technology. The quickest response time is critical for fire application., -Morgan Hertel, VP of Technology and Innovation, Rapid Response Monitoring Features BACKUP BATTERY UL listed and NFPA compliant Enclosure capacity for two 14AH A compact inteUigentFAcP batteries. Will charge up to two 18 AR batteries. Sealed lead acid batteries - 6 Programmable Zone Inputs requires 2 each 12 VOC UL-recognized. 1 Notification Appliance Circuit (NAC) with strobe synchronization ANTENNA NAC supports all major synchronization patterns Supplied 2.5 dB tamper resistant Power Supply charges up to (2) 18AH batteries, providing power to meet iclosure mount antenna. Optional any jurisdiction's requirements niote mounting antennas available, Supports Potter RA-6075 Remote Annunciator via the P-Link bus COMPATIBLE RECEIVER 7705i AES-Mu/tiNet Red metal enclosure with a key lock and Lexan window for viewing the system status ALARM SIGNAL INPUTS 32 (2 x 16) character LCD dispray with system LEDs for dear system status 6 Programmable Initiating Device Circuits 1 input - Type A (four wire) or Keypad for access to the system Type 8 input (two wire) Easy configuration with Programming Software 5 inputs - Type B Cabinet mounted subscriber antenna or optional remote antenna capability SMOKE DETECTOR COMPATIBILITY Email notification capability for sending system status, reports, system Compatible with a large number of listed 2 wire models including: configuration, or service reminder messages Benefits System Senors Detection Systems ESL Hochlki Fenwal Potter Highly integrated turnkey single-box solution Ideally suited for small to mid-size installations NAC OUTPUT Compatible With a large number of Innovative solution leveraging AES-IntelliNet® patented mesh radio listed 2 wire models including: technology and Potter proven FACP Amseco Geritex High speed communication between AES subscriber and panel eliminates Potter/Gentex Eaton . need for DACT Cooper Wheelock AES subscriber provides primary communications path System Sensor I No telephone lines are required NAC PATTERNS Easy installation saves time and lowers cost of deployment Temporal & Cadence patterns 1 Simple and flexible single point configuration JISUAL INDICATORS WCD (2 x 16 Alphanumeric Provides fast alarm communication and reporting to the Central Monitoring Station Character Display) . Streamlines AHJ approval process reducing installation time and deployment cost LED indicators - Control Panel and Subscriber The AES Corporation global service and technical support team is available 24/7 as single point of contact I Technical Specifications (continued) 1 Overview .NFIGURATION INTERFACE The AES Corporation model 7706-ULF was engineered in close collaboration with pad with function, number and navigation keys Potter Electric Signal Co., designed specifically for small to mid-size fire protection applications. The 7706-ULF is a single-box integrated solution, bringing together ALARM SYSTEM PROGRAMMING INTERFACE AES-InteII!Net® patented alarm communications technology and Potter's proven Ethernet using programming software I Fire Alarm Control Panel (FACP) for life safety. SUBSCRIBER PROGRAMMING The AES 7706-ULF Integrated Fire Monitoring System is a compact, simple panel INTERFACE designed to monitor and communicate the alarm status to a Central Monitoring Control Panel LCD and keypad Station. The 7706-ULF system is a listed and approved microprocessor-based fire UL STANDARDS monitoring panel and complies with UL-864 requirements as well as NFPA-70 and Meets UL- 864 9th Edition - Standard NFPA- 72 National Fire Alarm and Signaling Code. The panel features 6 Inputs and - for Control Units and Accessories for Fire Alarm Systems one 24 VDC 0.5A Notification Appliance Circuit (NAC) with strobe synchronization. The 2.OA Power Supply provides ample power to meet any jurisdiction's requirements, OPERATING TEMPERATURE RANGE 00 to 49° c(32° to 120°F) also has capacity to charge up to (2) 18AH batteries. In addition, the panel includes the Potter Signal P-Link for connection to a remote annunciator. STORAGE TEMPERATURE RANGE -10° to 60°C (140 to 140°F) The Panel Interface Card, jointly developed by AES and Potter, provides a high-speed RELATIVE HUMIDITY RANGE bi-directional communications interface between the fire control panel and the o to 93% RHC, Non Condensing AES 7788F subscriber. This allows alarm and status messages generated by the panel to be sent directly to the subscriber for transmission on the AES private wireless About AES Corporation i network. It also allows the panel to supervise the subscriber status to annunciate local AES Corporation is the leading I manufacturer of code compliant trouble if the subscriber is not functioning correctly. wireless alarm communication Alarm signals, supervisory and trouble messages are transmitted through the products and solutions serving .omniercial security markets and AES 7788F Fire subscriber built into the panel enclosure. The panel zone input vernment agencies worldwide. configuration Is done with the Potter Signal panel configuration software over the AES!nte!IINet@patented TCP/IP network access port. The 7706-ULF keypad interface provides access to the technology will never sunset AES subscriber for configuration and status information. compared to obsoleting technologies such as cellular The AES 7706-ULF provides the Central Monitoring Station capability to quickly and traditional phone lines. AES detect any alarm condition. This is a complete departure from the use of traditional private mesh radio networks are phone lines, providing a high speed link between the alarm panel and the AES Smart owner operated and controlled, providing Infinite scalability and i Subscriber. This link is always active and always supervised on both sides. The superior reliability with the fastest 7706-ULF with the built-in AES 7788F Smart Subscriber provides end-to-end agility transmission speed available. Over and a fault tolerant system. a half million AES Smart Subscribers are installed worldwide. AES is When it comes to preventing loss of life or property, network owners and operators as the clear choice for life safety and well as first responders rely on AES-IntelliNet® global alarm communications technology. security, protecting people and properly for over 40 years. How to Order 7706-ULF 7706-ULF Integrated Fire Monitoring System @POTffR Wwwofteftwo ® . cs 5J/ 2J NetOiie CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1516:0111 Page 1 of I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: AES CORPORATION285 NEWBURY ST, PEABODY, MA 01960 Contact: Owais Hassan (978) 535-7310 Ext: 263 Fax (978) 535-7313 Email: OHassan@aes-intellinet.com DESIGN: Model 7706-ULF Integrated Control Unit and Subscriber Unit fire alarm control unit. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. S 08.18..15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other 5 Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S SYSTEM $ SENSOR Photoelectric Smoke Detectors System Sensor j3' series smoke detectors represent significant advancement in conventional detection. The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings LISTED S911 MEA M$FM approved approved 301446 7272-1653A 52 290'01' 2093 G. 31843932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (Included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire il detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityof l detectors in terms of percent-per-foot obscuration. Instant Inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. 91 (j) Smoke Detector Specifications Smoke detector shall be a System Sensor j3 Series model nuniber _. listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B. 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WF-8) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3½-Inch and4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured In the Ut. smoke box The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2Wr-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to Indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24 V non-polarized Minimum: 83V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 p maximum average; 4-wire: 50 p maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V.23 mA @ 24V Peak Standby Current 2-wire: 100pk 4-wire: n/a Alarm Contact Ratings Physical Specifications Dimensions (including base) 2-wire: ri/a; 4-wire: 05 A @ 30V AC/DC 53 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6302(1789) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (572°C) fixed Freeze Trouble 2WT-8 and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG S Mounting 'LED Modes 316-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-Inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Power-Up Sequence for LED Indication Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every S seconds off Out of sensitivity off Blink every S seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal 2W-B No Wiring Alarm Current 2-wire 130 mA max. limited by control panel 2WT-8 Yes 2-wire 130 mA max, limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20mA@12V.23mA@24V Accessories 2W-MOD2 2-wire loop test / maintenance module - FIT Removal / replacement tool SENS-RDR Sensitivity reader. A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter ('\ c)'STEA,l SENSOR' 3825 Ohio Avenue .St. Charles, IL 60174 Phone: 800-SENSOR2. Fax: 630-377-6495 S. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 oil CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell 1nt41 Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4Wr-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4W1-B are 4-wire detectors. Models 2WT-8 and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 05-20-05 This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other' data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, Installation Instructions and/or other 9 Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 6 (DPOTTER PULL STATION SERIES' DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS L I • UI. and cUL Listed, FM Approved, CSFM Listed, MEA Approved, ADA Compliant Single or Dual Action MOO_ . Terminal connectors Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox Surface backboxes available High-gloss red enamel finish Glass breakrod t. • Made in the U.S.A. Description The Potter Pull Station Series offers a complete line of die-cast pull stations for a variety of applications focusing mainly on fire alarm systems. The pull stations are available in single or dual action models. All of the pull stations have a 10-amp snap action switch and a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The standard models have a hex key reset, however a key reset is also available. The models arc available with shallow and deep surface mount back boxes and as a weatherproof version. . Operation The Potter single action series of pit11 stations operate by pulling the white operating handle straight down and the handle will lock into place. The dual action stations require the lifting of the front cover and then pulling the white operating handle straight down. The stations are reset by opening the front and placing the handle in the normal position. Ordering information Engineering Specifications The contractor shall furnish and install the Potter series of pull stations as indicated. The pull station shall be die cast construction with a '1 type pull handle that is ADA compliant. Single action pull stations shall be a P32-IT. Dual action pull stations shall be the Potter P32-IT-LP. Any manual pull station installed in an outdoor or wet location shall bea RMS- 1T-WP weather proof unit. The contact shall be a single pole, single throw switch rated at I amp 30V DC/I25V AC. The device shall have a terminal block for ease of wiring. Once activated, the pull station shall be reset by opening the front cover. Opening of the cover in a normal state shall initiate an alarm. Specifications Switch Rating: I Amp @ 30 VDC l0 Amps @125VAC Pull Station Dimensions: 4-3/4" H x 3-1/4' W 7/8" D Color: Red with raised white letters, white pull bar with raised red letters For special application manual stations see bulletin #8910014. For explosion proof manual stations see bulletin #88800/4. Type Model Number Stock Number Contact Type Single Action P32-IT 1000447 SPST RMS-2T 1000477 DPST RMS-6T 1000478 DPDT RMS-lT-KI. 1000451 SPST RMS-IT.KO 1000450 SPST, key operated, no pull Weather Proof RMS-1T.WP 1000401 SPST Dual Action P32-IT-LP 1000476 Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods (10 per pkg) is Potter Electric Signal Co., LLC • St. Louis, MO. Cust Service: 866-240-1870 • Tech Support: 866-956-1 211 • Canada 888-882-1833' www.pottcrsignal.com PRINTED IN USA MKT. #8900097 . REV L PAGE I OF I 9110 7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION "CAL OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7150-0328:0156 Page 1 of 1 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignaicom DESIGN: Models P32-1T (alien or key, no push bar) and P32-1T-LP (key lock or alien key) noncoded manual pull stations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10 Amp. @ 120 VAC, 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1039:0101 Rev 8-3-2009 flu This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or, Installation criteria. Refer to listee's data sheet, installation instructions and/or other is Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CAST1LLO, Program Coordinator Fire Engineering Division g SYSTEM 4 SENSOR Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications Spectrkerft Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting SPECTFlert JLX_ Aft JYJL The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installatibn. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SiGNALING ®€MEA S USTED AM&= $4011 tcl*n5, horn strobes. horns) 3023572 chirno Strobes)$$512(c1robes) 7135-1653: 180 (horns cho-res) approved MEA4S2-05-E 7125-16W: 186 (indoor strobes) 1125-1653188 (horn strobes, SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shalt mount to a standard 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync'Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.6 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150. 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrJert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for tire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FINR or regulated 24 DCIF\NR Operating Voltage Range2 6 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8,5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wail-Mount Dimensions (including lens) 5.6L x 4.7W x 2.5'D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7W x 1.3D (142 mm Lx 119 mm x 33 mm D) Wall-MountTrlm Ring Dimensions (sold as a pack) (TR-HS) 5.7L x 4.8W x 0.35"D (145 mm L x 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 10 UL Max. Horn Current Sound Pattern Draw (mA dB RMS) 8-17.5 Volts DC FWR 16-33 Volts DC FWR Temporal High 51 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 - 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data S puI Strobe 1a Draw I17i1;l!Ij 8-11.5 Volts Candela DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15175 142 148 77 81 Range o NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 10 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA DC Input RMS), 2-Wire 8-17.5 Volts 15 Horn Strobe, 15175 Standard 16-33 Volts 15 Candela 15175 Range (15-115 30 cd) 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High • 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max. Current Draw (mA DC Input 132 154 RMS), 2-Wire Horn 16-33 Volts 135 150 80 Strobe, High 177 185 Candela 90 105 Range (135-185 cd) FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data and Horn Horn Strobe Output (dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 at Coded Coded Medium Low 78 78 74 75 85 81 85 81 90 88 90 85 97 96 98 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes, SpectrAlert Advance Dimensions n Ii1 Wall-mount horn strobes SpectrAlert Advance Ordering Information I!LTInII1rR11i1I.n Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P28-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red -Model Description Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, ¶IJEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, While SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P48H 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, 'FUEGO" Notes: All-P models have a plain housing (no 'FIRE" marking on cover) All -SP models have 'FlJEGO' marking on cover Standard cd" rotors to strobes that include 15, 15/75, 30, 75,95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. 0 "' 5'STEIL'1 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 5,IvcoR' 1mai,oi cua 5e lc5 sJo daD Om stomsensorcom AvoSI020 /I1 12 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.Iinhart©systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes, Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix °K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBG (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDCIFWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as ahor..Jsfrobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime Section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 13 S Honeywell I Cable Fire Alarm Cable Part Number: 4306 Description 18 AWG 2 Solid Conductors with Jacket. Ratings FPLR/CL2R, FT4 Sunlight Resistant Approvals UL Listed Construction Conductor Type 18 AWG Solid Bare Copper Conductor Count 2 Insulation Colors Black, Red Insulation Type Polypropylene Insulation Thickness 0.006" nom. Cable Lay Length 2.00" Shielding N/A Rip Cord Yes Jacket Material PVC Jacket Thickness 0.016" nom. Overall Outer Diameter 0.144" nom. Flame Rating UL 1666 (Riser), CSA C22.2 No. 2556 (FT4) Print Legend HONEYWELL P/N 4306 2C18 E175105 (UL) FPLR OR CL2R FT4 SUN RES (RoHS) 75C W/0 #XXXXXX-XXXXXX XXXX FT DEVICE/ZONE A B C D E F 12 34 56 7 8 9 Electrical & Environmental Temperature -20°C to 75°C Voltage 300V max. Capacitance 22.8 pF/ft. nom. Impedance 67 Ohms nom. DC Resistance 6.52 Ohms/I000' at 20°C RoHS Compliant Yes Packaging & Colors Standard Packaging 1000' or 500 Speed Box6 Pull Box Standard Color(s) Red Other packaging and color options available at http://www.honeywellcable.com [IJ REV B 10/05/16 DOD 14 Honeywell GENESIS SERIES Description: 18 AWG 2/C DIRECT BURIAL FPL Compliance: UL Standard 13 AND 1424; NEC Article725 & 760 Conductor 18 AWG Stranded Bare Copper No. of Conductors 2 Insulation Type SRPVC Color Black, Red Thickness 0.020" nom. Diameter 0.085" nom. Lay Length 5.5" nom. Jacket Type PVC Color BLACK Thickness 0.045' nom. Diameter 0.260" nom. HONEYWELL PIN 4156 2C18 E175105 (UL) FPL OR CL2 SUN RES DIR BUR (RoHS) Legend (ink Print) W/O #xxxxxx-xxx XXXXFT DEVICE/ZONE A8CDEF123456789 Properties Temperature Rating -20 to 60 °C Operating Voltage 300 Volts max. Capacitance 19 pf/ft nom. Impedance 103 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 1.685 Vertical Tray S REV AO9/OI/IOOA 145 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: GENESIS CABLE SYSTEM770I 95TH Street, Pleasant Prairie, WI 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orville@genesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP. HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Ootional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having Jurisdiction. MARKING: Listee's name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division j4p