Loading...
HomeMy WebLinkAbout2330 FARADAY AVE; ; FPC2016-0009; Permiti1 i PI :1111]41 city of Carlsbad Print Date: 03/31/2022 Permit No: FPC2016-0009 Job Address: 2330 FARADAY AyE, CARLSBAD, CA 92008-7216 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 11/17/2016 Valuation: $0.00 Lot #: Issued: 12/06/2016 Occupancy Group: Project #: Finaled Close Out: 03/02/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: BUILDING 2330 -INSTALLATION OF FIRE ALARM SYSTEM TO MONITOR SPRINKLER SYSTEM FPContractor: SENTINEL SECURITY SYSTEMS-INACTIVE P0 BOX 300577 ESCONDIDO, CA 92030-0577 (760) 741-0890 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov S BUILDING 2330 2330 FARADAY AVENUE CARLSBAD, CA 92008 SPECIFICATION DOCUMENTATION FOR: FIRE ALARM SYSTEM SENTINEL SECURITY SYSTEMS 1859 S. ESCONDIDO BLVD ESCONDIDO, CA 92025 0) C 0 o LU I (0 > < 0 • C'sl ()L .. C c) LI- N SUBMITTED BY: ZAK PESCAR PHONE 4*: 760.741.0890 11/15/2016 TABLE OF CONTENTS AES 7706- ULF DATA SHEETS •PAGES 1-2 FACP LISTING SHEET PAGES 3 S PHOTOELECTRIC SMOKE DETECTORS MANUEL PULL STATION SERIES INDOOR SELECTABLE- OUTPUT HORNS, STROBES DATA SHEETS PAGES 4-5 LISTING SHEET PAGE 6 DATA SHEETS PAGES 7 LISTING SHEET PAGE 8 DATA SHEETS PAGES 9-12 LISTING SHEET PAGE 13 HONEYWELL FIRE ALARM DATA SHEETS PAGES 14-15 CABLE LISTING SHEET PAGE 16 `AES aes-corp.com COROORATION - Technical Specifications DIMENSIONS 11/2H x 14114'W x 4•3/4"D (46.c cm H x 36.1 cm W x 12.1 cm D) WEIGHT Approximately 17 pounds (3 kilograms), excludes battery - CABINET COLOR Red AC POWER INPUT 120VAC 60Hz 1.0 AMP Integrated Fire Monitoring System 7706-ULF "The AES 7706-ULF delivers fire alarm signals much faster to the central monitoring station in comparison to existing DACT technology. The quickest response time is critical for fire application." -Morgan Hertel, VP of Technology and Innovation,13 Rapid Response Monitoring Features UL listed and NIPA compliant A compact intelligent FACP 6Programmable Zone Inputs 1 Notification Appliance Circuit (NAC) with strobe synchronization NAC supports all major synchronization patterns Power Supply charges up to (2) 18AH batteries, providing power to meet any jurisdiction's requirements Supports Potter RA-6075 Remote Annunciator via the P-Link bus Red metal enclosure with a key lock and Lexan window for viewing the system status 32 (2 x 16) character LCD display with system LEDs for clear system status Keypad for access to the system Easy configuration with Programming Software Cabinet mounted subscriber antenna or optional remote antenna capability Email notification capability for sending system status, reports, system configuration, or service reminder messages Benefits Highly integrated turnkey single-box solution Ideally suited for small to mid-size installations Innovative solution leveraging AES•IntelliNet® patented mesh radio technology and Potter proven FACP High speed communication between AES subscriber and panel eliminates need for DACT AES subscriber provides primary communications path No telephone lines are required Easy installation saves time and lowers cost of deployment Simple and flexible single point configuration BACKUP BATTERY Enclosure capacity for two 14AH batteries. Will charge up to two 18 AH batteries. Sealed lead acid batteries - requires 2 each 12 VDC UL-recognized. ANTENNA Supplied 25 dB tamper resistant 'iclosure mount antenna. Optional mote mounting antennas available. COMPATIBLE RECEIVER 77051 AES-MuIfiNet ALARM SIGNAL INPUTS 6 Programmable Initiating Device Circuits 1 input - Type A (four wire) or Type B input (two wire) Sinputs - TypeB SMOKE DETECTOR COMPATIBILITY Compatible with a large number of listed 2 wire models including: System Senors Detection Systems ESL Hochiki lenwaI Potter NAC OUTPUT Compatible with a large number of listed 2 wire models including: Ainseco Geiitex Potter/Geritex Eaton Cooper Wheelock System Sensor NAC PATTERNS Temporal & Cadence patterns 'lSUAI INDICATORS Provides fast alarm communication and reporting to the Central Monitoring Station 0 (2 x 16 Alphanumeric Character Display) Streamlines AHJ approval process reducing installation time and deployment cost LED indicators - Control Panel and Subscriber I The AES Corporation global service and technical support team is available 24/7 as single point of contact Technical Specifications (continued) Overview .ONFIGURATION INTERFACE The AES Corporation model 7706-IJLF was engineered in close collaboration with .yPad with function, number and navigation keys Potter Electric Signal Co., designed specifically for small to mid-size fire protection applications. The 7706-ULF is a single-box integrated solution, bringing together ALARM SYSTEM PROGRAMMING I INTERFACE AES-Irne/IiNet® patented alarm communications technology and Potter's proven Ethernet using programming software Fire Alarm Control Panel (FACP) for life safety. SUBSCRIBER PROGRAMMING The AES 7706-IJLF Integrated Fire Monitoring System is a compact, simple panel INTERFACE designed to monitor and communicate the alarm status to a Central Monitoring Control Panel LCD and keypad Station. The 7706-ULF system is a listed and approved microprocessor-based fire UL STANDARDS monitoring panel and complies with UL-864 requirements as well as NFPA-70 and Meets UL- 864 9th Edition - Standard for control Units and Accessories for NFPA- 72 National Fire Alarm and Signaling Code. The panel features 6 Inputs and Fire Alarm Systems : one 24 VDC O.SA Notification Appliance Circuit (NAC) with strobe synchronization. The 2.OA Power Supply provides ample power to meet any jurisdiction's requirements. OPERATING TEMPERATURE RANGE 00 to 490 C (32° to 120°F) also has capacity to charge up to (2) 18AH batteries. In addition, the panel includes the I Potter Signal P-Link for connection to a remote annunciator. STORAGE TEMPERATURE RANGE I .100 to 60° C (14° to 140°F) The Panel Interface Card, jointly developed by AES and Potter, provides a high-speed RELATIVE HUMIDITY RANGE bi-directional communications interface between the fire control panel and the 0 to 93% RHC, Non Condensing AES 7788F subscriber, This allows alarm and status messages generated by the panel to be sent directly to the subscriber for transmission on the AES private wireless About AES Corporation network. It also allows the panel to supervise the subscriber status to annunciate local AES Corporation is the leading manufacturer of code compliant trouble if the subscriber is not functioning correctly. wireless alarm communication Alarm signals, supervisory and trouble messages are transmitted through the products and solutions serving ommercial security markets and AES 7788F Fire subscriber built into the panel enclosure. The panel zone input overnment agencies worldwide, configuration is done with the Potter Signal panel configuration software over the AESIntelIiNet®patented TCP/IP network access port. The 7706-ULF keypad interface provides access to the technology will never sunset AES subscriber for configuration and status information. compared to obsoleting technologies such as cellular The AES 7706-ULF provides the Central Monitoring Station capability to quickly and traditional phone lines. AES I detect any alarm condition. This is a complete departure from the use of traditional private mesh radio networks are i phone lines, providing a high speed link between the alarm panel and the AES Smart owner operated and controlled, providing infinite scalability and I Subscriber. This link is always active and .always supervised on both sides. The superior reliability with the fastest 7706-ULF with the built-in AES 7788F Smart Subscriber provides end-to-end agility transmission speed available. Over and a fault tolerant system. a half million AES Smart Subscribers are installed worldwide. AES is When it comes to preventing loss of life or property, network owners and operators as the clear choice for life safety and well as first responders rely on AES-IntelliNet® global alarm communications technology. security, protecting people and property for over 40 years. 7706-ULF 7706-ULF Integrated Fire Monitoring System ®P9TT& LISTED NFPAt ' :1 NetOnc CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1516:0111 Page 1 of I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: AES CORPORATION285 NEWBURY ST, PEABODY, MA 01960 Contact: Owals Hassan (978) 535-7310 Ext: 263 Fax (978) 535-7313 Email: OHassan@aes-lntellinet.com DESIGN: Model 7706-ULF Integrated Control Unit and Subscriber Unit fire alarm control unit. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. RATING: 120 Vac INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes and ordinances and In a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices, NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 08-18-15 gt This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation Instructions and/or other S Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Photoelectric Smoke Detectors System Sensor j3 series smoke detectors represent significant advancement in conventional detectio The j3 family is founded on three principles: instalk4 0 ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings @ <~> A MEA MSFM LISTED approved approved 5911 3011446 7212-1653:152 290-01 -E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, j3 heads plug into the base with a simple Stop-Drop 'N Lock action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. 2-wire P detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors In terms of percent-per-foot obscuration. Instant Inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire j3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. IN (j. Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor j3 Series model nursber listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2Wr-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall Include a mounting base for mounting to 31/2-inch and4-Inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting Its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2W1-B, 4WT-B) conditions. When used In conjunction with the 2W-MOD2 module, 2-wire models shall Include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verily the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polanzed Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 ljA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V.23 mA @ 24V Peak Standby Current 2-wire: 100 pA 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 03 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 Inches (5) mm) height Weight 63oz(178g) Operating Temperature Range 2W-8 and 4W-B: 32°F to 120°F (0°C to 49°C); 2W1-B and 4Wr-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2W1-8 and 41/i1-B only: 41°F (5°C) Sensitivity 25%/ft nominal InputTerminals 14 to 22 AWG . Mounting 31/2-inch octagonal back box 4-Inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds - Initial LED status indication 80 seconds Normal (standby) Blink every S seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information LModel Thermal 2W-8 No Villiir. 2-wire Alarm1TTI17i1Tl 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-8 No 4-wire 20mA@12V23mA@24V 4W1-B Yes 4-wire 20 mA @ 12 V, 23 mA @24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT SENS-RDR Sensitivity reader A77-A82 Removal / replacement tool Retrofit adapter bracket, 6.6 inch (16,76 cm) diameter SV'S7E11,7 SENSOR" 3825 Ohio Avenue . St. Charles, lL6O174 02M Phone: 800-SENSOR2 -Fax: 630-377-6495 Sys kno'. xt oisAecI ch t,oi ot4, ccnb 6109 . S7I69 S0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.Iinhart©systemsensor.com DESIGN: Models 2W-8, 2Wr-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor Is are supplemental to the detector and is not Intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, installation Instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (DPOTTER PULL STATION SERIES O DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS UL and cUL Listed, FM Approved, CSFM Listed, MEA Approved, ADA Compliant Single or Dual Action - : Switch ___________ Gold plated SPST contacts Optional auxiliary contacts _____ on:, . * . Mounts on standard single gangbox Surface backboxes available High-gloss red enamel finish Glass breakrod 1• • Made in the U.S.A. Description The Potter Pull Station Series offers a complete line oldie-cast pull stations for a variety of applications focusing mainly on fire alarm systems. The pull stations are available in single or dual action models. All of the pull stations have a 10-amp snap action switch and a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The standard models have a hex key reset, however a key reset is also available. The models are available with shallow and deep surface mount back boxes and as a weatherproof version. Ordering Information Engineering Specifications The contractor shall furnish and install the Potter series of pull stations as indicated. The pull station shall be die cast construction with a "T" type pull handle that is ADA compliant. Single action pull stations shall be a P32-IT. Dual action pull stations shall be the Potter P32-I T-LP. Any manual pull station installed in an outdoor or wet location shall baa RMS-1T-WP weather proof unit. The contact shall be a single pole, single throw switch rated at I amp 30V DC/ l25V AC. The device shall have a terminal block for ease of wiring. Once activated, the pull station shall be reset by opening the front cover. Opening of the cover in a normal state shall initiate an alarm. Specifications Switch Rating: 1 Amp @ 30 VDC 10 Amps @125 VAC Pull Station Dimensions: 4-314" H x 3-1/4" W x 7/8" D Color: Red with raised white letters, white pull bar with raised red letters For special application manual stations see bulletin 98910014, For explosion prooJ'manua/ stations see bulletin #88800/4, S Operation The Potter single action series of pull stations operate by pulling the white operating handle straight down and the handle will lock into place. The dual action stations require the lifting of the front cover and then pulling the white operating handle straight down. The stations are reset by opening the front and placing the handle in the normal position. Type Model Number Stock Number Contact Type Single Action P32-IT 1000447 SPST RMS-2T 1000477 DPST RMS-6T 1000478 DPDT RMS-1T-KL 1000451 SPST RMS-IT-KO 1000450 SPST, key operated, no pull Weather Proof RMS.IT-WP 1000401 SPST 1000403 Dual Action P32-IT-LP 1000476 Weather Proof Dual Action RMS-IT-WP-LP Accessories Notes Dual Action' RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods (10 per pkg) Potter Electric Signal Co.. LLC • St. Louis, MO • Cust Service: 866-240-1870- Tech Support: 866-956-12 II• Canada 888-882-1833 www.pottcrsignal.com 0 1 PRINTED IN USA MKT. #8900097 - REV L PAGE I OF I 9110 hr CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL -- FIRE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: S 7150-0328:0156 Page 1 of 1 7150 - FIRE ALARM PULL BOXES Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BilIWpottersignal.com Models P32-IT (alien or key, no push bar) and P32-1T-LP (key lock or alien key) noncoded manual pull stations. Refer to listee's data sheet for additional detailed product description and operational considerations. 10 Amp. @ 120 VAC, 30VDC In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as manual pull stations for use with separately listed and compatible fire alarm control units. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. 7150-1039:0101 *Rev 8-3-2009 fm it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, installation instructions and/or other is Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division 4 SYSTEM S SENSOR Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrA/en® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15175 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75,95,110,115,135,150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wail mounting Ell I I PEI" 11 —4 a The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIQJIAUNO ®FM . LISTED MEA approved 7125 1oS3:180(.ndornssob.) 7125-1653:188 )bon snobn. $4011 )cflhins. horn 00brn. horns) 3023572 S5512fst,obss) MEM52-05-E chose strobes) 7135.1653 189 (horns, thbnn) 9 SpectrAlert Advance Specifications S VArch itect/Enjnh11Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate, Also, SpectrAlert Advance products, when used with the Sync'Clrcuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115,135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair 01 wires. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style V (class B) circuits or one Style 2 (class A) circuit. The module shalt synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 101093% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V (24 V nominal) lnputTermlnal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7W x 2.5D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4,7W x 13D(142 mm Lx 119 mm W x 33 mm 0) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TA-KS) 53'L x 4,8W x 035"D (145 mm L x 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P. S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 11 10 UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15175 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA Candela iso NA NA Range —177 NA NA ,i.Max. HornICurrent Sound Pattern I' dB .1 8-17.6 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 51 -- 69 75 Coded Medium 44 56 69 Low 40 46 52 50 228 207 246 220 Coded 281 251 185 NA NA 286 258 IFFIRIFromm7mo =7 DC Input V 8-17.5 Volts 15 15)75 16-33 Volts 15 1575 30 75 95 110 115 Temporal High 137 147 79 90 V 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 V96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High • 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low DC Input 132 154 16-33 Volts 135 150 80 177 90 185 105 161 FWR Input 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Nnn-Temnoral Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data horn and Switch Position horn Strobe I'UtpUt Sound Pattern (CIOA) dB 8-175 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium V 78 78 65 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 81 Coded Medium 78 76 85 85 90 90 97 98 91 Coded Low 74 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2-wire horn strobes. Wall Strobes (cont) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White SpectrAlert Advance Dimensions S Wall-mount horn strobes 0 M SpectrAlert AdvanceOrderingInformation I[P111lThLi1i Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP2-Wire Horn Strobe, Standard cd, Red, FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Notes: All -P models have a plain housing (no FIRE marking on cover) All -SP models have FtJEGO marking on cover Standard cd" refers to strobes that include 15,15f75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings ;- SYSTEM SENSOR' 3825 Ohio Avenue • St. Charles, IL 60174 W014 SWCM Son= Phone: 800-SENSOR2 • Fax: 630-377-6495 l 'cSueng 'e laos 3 data OWwww.systemserisor.com vsiooi. 1114 /2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, 132W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and 134WI-I Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating Indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering, °K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC, (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: . In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *hostrobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -1< suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and Indoor use only. Horn/Strobes or chime/strobes can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria, Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 13 Honeywell I Cable Fire Alarm Cable Part Number: 4306 Description 18 AWG 2 Solid Conductors with Jacket Ratings FPLR/CL2R, FTLI Sunlight Resistant Approvals UL Listed Construction Conductor Type 18 AWG Solid Bare Copper Conductor Count 2 Insulation Colors Black, Red Insulation Type Polypropylene Insulation Thickness 0.006 "nom. Cable Lay Length 2.00 Shielding N/A Rip Cord Yes Jacket Material PVC Jacket Thickness 0.016 nom. Overall Outer Diameter O.144 nom. Flame Rating UL 1666 (Riser), CSA C22.2 No. 2556 (FTLI) Print Legend HONEYWELL P/N 4306 2C18 E175105 (UL) FPLR OR CL2R FT4 SUN RES (RoHS) 75C W/O #XXXXXX-XXXXXX XXXX FT DEVICE/ZONE ABC D E F 123456789 Electrical & Environmental -20°C to 75°C Temperature Voltage 300V max. Capacitance 22.8 pF/ft. nom. Impedance 67 Ohms nom. DC Resistance 6.52 Ohms/1000' at 20°C RoHS Compliant Yes Packaging & Colors Standard Packaging 1000 or 500' Speed BoxO Pull Box Standard Color(s) Red Other packaging and color options available at http://www.honeywellcable.com Ll REV B 10/05/16 DOD ':1 Honeywell GENESIS SERIES Description: 18 AWG 2/C DIRECT BURIAL FPL Compliance: UL Standard 13 AND 1424; NEC ArticIe725 & 760 Conductor 18 AWG Stranded Bare Copper No. of Conductors 2 Insulation Type SRPVC Color Black, Red Thickness 0.020" nom. Diameter 0.085" nom. Lay Length 5.5" nom. Jacket Type PVC Color BLACK Thickness 0.045" nom. Diameter 0.260" nom. HONEYWELL PIN 4156 2C18 E175105 (UL) FPL OR CL2 SUN RES DIR BUR (RoHS) Legend (ink Print) W/O #Xxxxxx-xxx XXXXFT DEVICE/ZONE ABCDEFI 23456789 Properties Temperature Rating -20 to 60 °C Operating Voltage 300 Volts max. Capacitance 19 pf/ft nom. Impedance 103 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 1685 Vertical Tray REV A 09/01/10 OA 145 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:0100 Page 1 of 1 CATEGORY: 7161 - CABLES-FIRE PROTECTIVE SIGNALING LISTEE; GENESIS CABLE SYSTEM7701 95TH Street, Pleasant Prairie, WI 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orvllle@genesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gltto/Global Corp., Grade GA-91-84,GPT-45, GA5033, GA93016 Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not - an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other S Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CAST!L.LO, Program Coordinator Fire Engineering Division 40