HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; 100; FPC2020-0101; PermitJ4:i rIl;a1I.]:i k-city of Carlsbad Print Date: 03/31/2022 Permit No: FPC2020-0101 Job Address: 1950 CAMINO VIDA ROBLE, # 100, CARLSBAD, CA 92008-6599 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120931200 Track #: Applied: 06/11/2020 Valuation: $4,611,280.46 Lot #: Issued: 08/13/2020 Occupancy Group: Project #: DEV2019-0138 Finaled Close Out: 01/28/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: RAF PACIFICA GROUP FUSION Description: ALPHA TECH (ATEC) - ADD/RELOCATE SPRINKLERS, INSTALL NEW PRE-ACTION SYSTEM, PLACE SPRINKLERS AT WAREHOUSE F( ESFR K25 SPRINKLERS Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System> 100 heads $654.00 FIRE Reinspection (per inspection) $193.00 Total Fees: $1,801.00 Total Payments To Date: $1,801.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A ik" ~AML Frc%~O-o(o~ FtRfl PROTICTION Fire Protection Contractor - License #989280 FIRE SUPRESSION HYDRAULIC CALCULATIONS ATEC 1950 CAMINO VIDA ROBLE, CARLSBAD, CA 92008 CONTRACT NO. 19572 2880 Scolt Sfreef, Suite 105- V!ta, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page No. 219 0 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Alphatec Spine SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 1950 Camino Vida Roble CITY: Carlsbad PHONE: (760) 295-3436 (Titan Fire Protection) FAX NUMBER: (760) 295-3437 Largest Building (ft.2): 111,214 Sprinkled? Yes Construction Type: Ill-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Camino Vida Roble west of Owens Avenue TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 132 PSI Hydrant Number (if applicable):H60422 Elevation of test: 246 Feet Main Size: 16 INCH Pressure Zone: 550 Feet Date/Time of Test: Pitot Tube Reading: Psi Corresponding Flow: GPM Total Flow: 6.550 GPM Residual Pressure 109 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Based on the square footage of the building and construction type, a fire flow of 7,000 gpm is required. However, this exceeds the City's maximum velocity criteria. The fire flow that meets both velocity and pressure criteria is 6,550 gpm. No reduction for sprinklers has been included in this analysis. The maximum fire flow available onsite at Hydrant H61472 that meets the City's criteria is 2,580 gpm. This is due to a segment of 8-inch main on both the connections to Camino Vida Roble and Kellogg Avenue. The residual pressure during this event is 120 psi. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer R.Mael, _ P.E. Eng. Lic. No. (if applicable): C69606 Signature: c:'4__. Title/Org: P fc/Mana Date: 03/19/2020 4 4 7; rn 0 C) C) 4 4 8. 0 4 Project Site] .1 Cb 7e- PRIVATE RD Fire Hydrant H61472 / Max Flow = 2,580 gpm j2 3 3 3 / Legend /ZONE Pipe 3 w_Hydrant 550+ 4 Flow /4LFIre tion H60422 #219 Alphatec Spine (1950 Camino Vida Roble) - Fire Flow Analysis EXISTING FEATURES Sizes: U 21/2' U 3" U 8" U 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U G - with groove end OS&Y gate valves U L - less shut-off valves U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U - with cu ft/min meter APPLICATION Designed for installation on potable water fire protection lines to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE ASSE® Listed 1048 (Horizontal and Vertical Flow-Up) AWVVA Compliant C510 (Horizontal & Vertical Flow-Up) UL® Classified (Horizontal) C-UL® Classified (Horizontal) CSA® Certified (Horizontal and Vertical Flow-Up) FM® Approved (Horizontal and Vertical Flow-Up) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow-Up, except 10" vertical) MATERIALS Main valve body Cast Iron ASTM A126 Class B Access covers Cast Iron ASTM A126 Class B Coatings FDAApproved Epoxy finish Internals Stainless Steel, 300 Series Cast Bronze ASTM B 584 Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers DelrinTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) LI Gate valve tamper switch (OSY-40) IiI B A DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL B E E WITHOUT WITH OS&Y SIZE A WITHOUT C D OS&Y GATE OS&Y F GATE GATE GATE VALVES GATE VALVES OPEN VALVES VALVES VALVES in. Imm l I in. mm l in. mm in. Imm in. 1mm in. mm in. lmm in. mm 'I lbs. kg lbs. I kg 21/21 65 371/81 943 22 I 4 1102 10 I 254 163/8 416 13 7/81 352 4 1102 101 I 45.9 211 I 95.8 3 I 80 38 1/8 I 968 22 I 4 102 10 I 254 18 7/8 479 155/81 397 4 1102 101 I 45.9 231 1104.9 8 1200 711/81 1807 48 71/2191 16 406 373/4 959 291/41743 71/21191 847 1384.5 13231600.6 10 250 841/81 2137 58 1:9 9 1229 18 I 457 453/4 1162 35 3/81899 9 1229 14101640.1 222811011.5 FLOW CHARACTERISTICS MODEL 950DA 21/2" & 3" (STANDARD & METRIC) FLOW RATES (Ifs) 12.6 25.2 37.9 50.5 104 69 In 35 0 200 400 600 800 FLOW RATES (GPM) MODEL 950DA 8" & 10" (STANDARD & METRIC) FLOW RATES (us) 63.1 126.2 189.3 252.4 - -= - I ['III' 2000 3000 III 104 69 35 )0 a- FLOW RATES (GPM) *Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2' 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 PROTECTIVE ENCLOSURE 12" 2 MIN. 30 MAX. SUPPORT DIRECTION OF FLOW HãI• OUTDOOR INSTALLATION VERTICAL INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048, and supplied with full port OS&Y gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM A126 Class B), the seat ring and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backf low Preventer shall be a WILKINS Model 950DA. e 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-57( IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 19572 - Atec - Design TI & HilePile_FP design Building : FP3 Location : CAMINO VIDA ROBLE System Area 1 Contract : 19572 Data File : 19572 - Atec - Design TI & HilePile_FP design. AREA I -PEAK Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 19572 - Atec - Design TI & HilePile_FP design Date HYDRAULIC CALCULATIONS for Project name: ATEC Location: CAMINO VIDA ROBLE Drawing no: FP3 Date: 3-23-20 Design Remote area number: Area 1 Remote area location: WAREHOUSE Occupancy classification: HIGH HAZARD - GROUP A PLASTICS Density: - Gpm/SqFt Area of application: 12 SPRINK - SqFt Coverage per sprinkler: 100 - SqFt Type of sprinklers calculated: K25.2 @15 PSI No. of sprinklers calculated: 12 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1,433.45 -GPM @ 78.33 - Psi Type of system: WET Volume of dry orpreaction system: N/A - Gal Water supply information Date: 3-19-20 Location: SEE PLAN Source: CITY OF CARLSBAD Name of contractor: TITAN FIRE PROTECTION Address: 2880 SCOTT ST. Phone number: 760-295-3436 Name of designer: M. Marron Authority having jurisdiction: CITY OF SAN DIEGO Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 19572 - Atec - Design TI & HilePile_FP design Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 11.694 C2 - Residual Pressure: 95.8 D2 - System Flow : 1183.45 C2 - Residual Flow : 6550 D2 - System Pressure : 78.336 Hose ( Demand) : 250 D3 - System Demand :1433.45 Safety Margin : 39.081 iSO 140 -- 130 -- Cl I- 120 _______ R11° - - C2 E 100 ..-e-------- S90 D2 - 80 -- u 70 - R6° E5° 40 30 20 10 -Dl- - 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 3 19572 - Atec - Design TI & HilePile_FP design Date Fitting Legend Abbrev. Name 1/2 % 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zit Wilkins 950DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 19572 - Atec - Design TI & HilePile_FP design Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 2 27.0 25.2 15.0 na 97.6 0.1 100 15.0 45 27.0 25.2 15.43 na 98.99 0.1 100 15.0 48 27.0 17.28 na 50 27.0 35.05 na 99 24.0 39.35 na 100 24.0 39.36 na 101 24.0 39.4 na TR1 24.0 54.45 na BR1 0.5 64.93 na BF1 -3.0 67.55 na BF2 -3.0 76.99 na UG1 -3.0 77.96 na TEST 0.0 78.34 na 250.0 102 27.0 25.2 15.02 na 97.66 0.1 100 15.0 103 27.0 25.2 15.78 na 100.09 0.1 100 15.0 104 27.0 18.24 na 105 27.0 30.24 na 106 24.0 35.54 na 107 24.0 35.56 na 108 24.0 35.62 na 109 24.0 35.74 na 110 24.0 35.84 na 111 24.0 35.94 na 112 24.0 36.01 na 113 24.0 36.08 na 114 24.0 36.14 na 115 24.0 36.19 na 116 24.0 36.23 na 117 24.0 36.26 na 118 24.0 36.29 na 119 24.0 36.31 na 120 24.0 36.33 na 121 24.0 36.34 na 122 24.0 36.54 na 123 24.0 36.65 na 124 24.0 36.65 na 130 24.0 38.35 na 131 24.0 38.35 na 132 24.0 38.35 na 133 24.0 38.36 na 134 24.0 38.37 na 135 24.0 38.38 na 136 24.0 38.39 na 137 24.0 38.41 na 138 24.0 38.44 na 139 24.0 38.48 na 140 24.0 38.52 na 141 24.0 38.57 na 142 24.0 38.63 na 143 24.0 38.69 na 144 24.0 38.77 na 145 24.0 38.86 na 146 24.0 39.27 na 147 24.0 39.39 na 148 27.0 30.26 na 149 27.0 18.25 na 150 27.0 25.2 15.78 na 100.11 0.1 100 15.0 151 27.0 25.2 15.02 na 97.68 0.1 100 15.0 152 27.0 25.2 15.01 na 97.62 0.1 100 15.0 153 27.0 25.2 15.44 na 99.01 0.1 100 15.0 154 27.0 17.29 na 155 27.0 35.06 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard TITAN FIRE PROTECTION, INC. Page 5 19572 - Atec - Design TI & HilePile_FP design Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 156 27.0 30.31 na 157 27.0 18.27 na 158 27.0 25.2 15.8 na 100.18 0.1 100 15.0 159 27.0 25.2 15.04 na 97.74 0.1 100 15.0 160 27.0 25.2 15.03 na 97.69 0.1 100 15.0 161 27.0 25.2 15.46 na 99.08 0.1 100 15.0 162 27.0 17.31 na 163 27.0 35.09 na 164 27.0 34.69 na 165 27.0 37.72 na 166 27.0 34.76 na 167 27.0 37.35 na 168 27.0 34.84 na 169 27.0 37.27 na 170 27.0 34.91 na 171 27.0 37.2 na 172 27.0 34.96 na 173 27.0 37.14 na 174 27.0 35.01 na 175 27.0 37.1 na 176 27.0 35.05 na 177 27.0 37.05 na 178 27.0 35.09 na 179 27.0 37.02 na 180 27.0 35.12 na 181 27.0 36.99 na 182 27.0 35.14 na 183 27.0 36.96 na 184 27.0 35.16 na 185 27.0 36.95 na 186 27.0 35.18 na 187 27.0 36.93 na 188 27.0 35.19 na 189 27.0 36.92 na 190 27.0 35.37 na 191 27.0 36.93 na 192 27.0 35.47 na 193 27.0 36.93 na 194 27.0 35.48 na 195 27.0 36.93 na 125 24.0 36.66 na 196 27.0 35.48 na 197 27.0 36.93 na The maximum velocity is 18.68 and it occurs in the pipe between nodes 108 and 156 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 82.88 2.157 0.0 8.000 15.000 K Factor = 25.20 to 120.0 0.0 0.0 0.0 45 82.88 0.0540 0.0 8.000 0.432 Vel = 7.28 45 98.99 2.157 0.0 8.000 15.432 K Factor= 25.20 to 120.0 0.0 0.0 0.0 48 181.87 0.2308 0.0 8.000 1.846 Vel = 15.97 48 0.0 2.157 T 10.0 66.960 17.278 to 120.0 0.0 10.000 0.0 50 181.87 0.2309 0.0 76.960 17.768 Vel = 15.97 50 0.0 2.157 T 10.0 3.000 35.046 to 120.0 0.0 10.000 1.299 99 181.87 0.2309 0.0 13.000 3.002 Vel = 15.97 99 0.0 6.357 0.0 10.000 39.347 to 120.0 0.0 0.0 0.0 100 181.87 0.0012 0.0 10.000 0.012 Vel = 1.84 100 181.90 6.357 0.0 9.500 39.359 to 120.0 0.0 0.0 0.0 101 363.77 0.0043 0.0 9.500 0.041 Vel = 3.68 101 819.68 6.357 T 30.0 321.800 39.400 to 120.0 3E 42.0 72.000 0.0 TR1 1183.45 0.0382 0.0 393.800 15.046 Vel = 11.96 TR1 0.0 8.249 B 18.133 24.500 54.446 to 150.0 0.0 18.133 10.178 BR1 1183.45 0.0071 0.0 42.633 0.303 Vel = 7.10 BR1 0.0 7.68 E 27.199 82.540 64.927 to 150.0 0.0 27.199 1.516 BFI 1183.45 0.0101 0.0 109.739 1.105 Vel = 8.20 BF1 0.0 8.27 4E 95.76 12.000 67.548 to 140.0 Zit 0.0 95.760 8.581 * * Fixed Loss = 8.581 BF2 1183.45 0.0080 0.0 107.760 0.859 Vel = 7.07 BF2 0.0 7.68 1 52.887 44.040 76.988 to 150.0 0.0 52.887 0.0 UG1 1183.45 0.0101 0.0 96.927 0.976 Vel = 8.20 UG1 0.0 9.42 F 16.622 273.420 77.964 to 150.0 2T 151.107 175.284 -1.299 TEST 1183.45 0.0037 G 7.555 448.704 1.671 Vel = 5.45 250.00 Qa = 250.00 1433.45 78.336 K Factor = 161.96 2 14.72 2.157 0.0 8.000 15.000 to 120.0 0.0 0.0 0.0 102 14.72 0.0022 0.0 8.000 0.018 Vel = 1.29 102 97.66 2.157 0.0 8.000 15.018 K Factor = 25.20 to 120.0 0.0 0.0 0.0 103 112.38 0.0948 0.0 8.000 0.758 Vel = 9.87 103 100.09 2.157 0.0 8.000 15.776 K Factor = 25.20 to 120.0 0.0 0.0 0.0 104 212.47 0.3078 0.0 8.000 2.462 Vel = 18.65 104 0.0 2.157 T 10.0 29.000 18.238 to 120.0 0.0 10.000 0.0 105 212.47 0.3078 0.0 39.000 12.005 Vel = 18.65 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 105 0.0 2.157 1 10.0 3.000 30.243 to 120.0 0.0 10.000 1.299 106 212.47 0.3078 0.0 13.000 4.002 Vel = 18.65 106 0.0 6.357 0.0 10.000 35.544 to 120.0 0.0 0.0 0.0 107 212.47 0.0016 0.0 10.000 0.016 Vel = 2.15 107 212.52 6.357 0.0 10.000 35.560 to 120.0 0.0 0.0 0.0 108 424.99 0.0057 0.0 10.000 0.057 Vel = 4.30 108 212.74 6.357 0.0 10.000 35.617 to 120.0 0.0 0.0 0.0 109 637.73 0.0122 0.0 10.000 0.122 Vel = 6.45 109 -47.68 6.357 0.0 10.000 35.739 to 120.0 0.0 0.0 0.0 110 590.05 0.0105 0.0 10.000 0.105 Vel = 5.96 110 -43.75 6.357 0.0 10.000 35.844 to 120.0 0.0 0.0 0.0 111 546.3 0.0092 0.0 10.000 0.092 Vel = 5.52 111 -42.29 6.357 0.0 10.000 35.936 to 120.0 0.0 0.0 0.0 112 504.01 0.0079 0.0 10.000 0.079 Vel = 5.09 112 -41.01 6.357 0.0 10.000 36.015 to 120.0 0.0 0.0 0.0 113 463.0 0.0067 0.0 10.000 0.067 Vel = 4.68 113 -39.88 6.357 0.0 10.000 36.082 to 120.0 0.0 0.0 0.0 114 423.12 0.0057 0.0 10.000 0.057 Vel = 4.28 114 -38.91 6.357 0.0 10.000 36.139 to 120.0 0.0 0.0 0.0 115 384.21 0.0048 0.0 10.000 0.048 Vel = 3.88 115 -38.07 6.357 0.0 11.000 36.187 to 120.0 0.0 0.0 0.0 116 346.14 0.0039 0.0 11.000 0.043 Vel = 3.50 116 -37.30 6.357 0.0 11.000 36.230 to 120.0 0.0 0.0 0.0 117 308.84 0.0032 0.0 11.000 0.035 Vel = 3.12 117 -36.67 6.357 0.0 11.000 36.265 to 120.0 0.0 0.0 0.0 118 272.17 0.0025 0.0 11.000 0.027 Vel = 2.75 118 -36.16 6.357 0.0 11.000 36.292 to 120.0 0.0 0.0 0.0 119 236.01 0.0020 0.0 11.000 0.022 Vel = 2.39 119 -35.77 6.357 0.0 11.000 36.314 to 120.0 0.0 0.0 0.0 120 200.24 0.0015 0.0 11.000 0.016 Vel = 2.02 120 -35.48 6.357 0.0 11.000 36.330 to 120.0 0.0 0.0 0.0 121 164.76 0.0009 0.0 11.000 0.010 Vel = 1.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 121 -35.27 3.26 0.0 12.000 36.340 to 120.0 0.0 0.0 0.0 122 129.49 0.0165 0.0 12.000 0.198 Vel = 4.98 122 -33.29 3.26 0.0 12.000 36.538 to 120.0 0.0 0.0 0.0 123 96.2 0.0095 0.0 12.000 0.114 Vel = 3.70 123 -32.10 6.357 0.0 12.000 36.652 to 120.0 0.0 0.0 0.0 124 64.1 0.0002 0.0 12.000 0.002 Vel = 0.65 124 -32.05 6.357 0.0 12.000 36.654 to 120.0 0.0 0.0 0.0 125 32.05 0.0001 0.0 12.000 0.001 Vel = 0.32 0.0 32.05 36.655 K Factor = 5.29 130 32.05 6.357 0.0 12.000 38.352 to 120.0 0.0 0.0 0.0 131 32.05 0.0 0.0 12.000 0.0 Vel = 0.32 131 32.05 6.357 0.0 12.000 38.352 to 120.0 0.0 0.0 0.0 132 64.1 0.0002 0.0 12.000 0.003 Vel = 0.65 132 32.10 6.357 0.0 12.000 38.355 to 120.0 0.0 0.0 0.0 133 96.2 0.0003 0.0 12.000 0.004 Vel = 0.97 133 33.29 6.357 0.0 12.000 38.359 to 120.0 0.0 0.0 0.0 134 129.49 0.0007 0.0 12.000 0.008 Vel = 1.31 134 35.27 6.357 0.0 11.000 38.367 to 120.0 0.0 0.0 0.0 135 164.76 0.0010 0.0 11.000 0.011 Vel = 1.67 135 35.48 6.357 0.0 11.000 38.378 to 120.0 0.0 0.0 0.0 136 200.24 0.0014 0.0 11.000 0.015 Vel = 2.02 136 35.77 6.357 0.0 11.000 38.393 to 120.0 0.0 0.0 0.0 137 236.01 0.0020 0.0 11.000 0.022 Vel = 2.39 137 36.16 6.357 0.0 11.000 38.415 to 120.0 0.0 0.0 0.0 138 272.17 0.0025 0.0 11.000 0.027 Vel = 2.75 138 36.67 6.357 0.0 11.000 38.442 to 120.0 0.0 0.0 0.0 139 308.84 0.0032 0.0 11.000 0.035 VeI= 3.12 139 37.30 6.357 0.0 11.000 38.477 to 120.0 0.0 0.0 0.0 140 346.14 0.0039 0.0 11.000 0.043 Vel = 3.50 140 38.07 6.357 0.0 10.000 38.520 to 120.0 0.0 0.0 0.0 141 384.21 0.0048 0.0 10.000 0.048 Vel = 3.88 141 38.91 6.357 0.0 10.000 38.568 to 120.0 0.0 0.0 0.0 142 423.12 0.0057 0.0 10.000 0.057 Vel = 4.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 9 19572 - Atec - Design TI & HitePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c'.or Ftng's Pe Pv Notes Point Qt P1/Ft Eqv. Ln. Total Pf Pn 142 39.88 6.357 0.0 10.000 38.625 to 120.0 0.0 0.0 0.0 143 463.0 0.0067 0.0 10.000 0.067 Vet = 4.68 143 41.01 6.357 0.0 10.000 38.692 to 120.0 0.0 0.0 0.0 144 504.01 0.0079 0.0 10.000 0.079 Vet = 5.09 144 42.29 6.357 0.0 10.000 38.771 to 120.0 0.0 0.0 0.0 145 546.3 0.0092 0.0 10.000 0.092 Vet = 5.52 145 43.75 6.357 2E 28.0 10.500 38.863 to 120.0 0.0 28.000 0.0 146 590.05 0.0105 0.0 38.500 0.406 Vet = 5.96 146 47.68 6.357 0.0 10.000 39.269 to 120.0 0.0 0.0 0.0 147 637.73 0.0121 0.0 10.000 0.121 Vet = 6.45 147 181.95 6.357 0.0 0.500 39.390 to 120.0 0.0 0.0 0.0 101 819.68 0.0200 0.0 0.500 0.010 Vet = 8.29 0.0 819.68 39.400 K Factor = 130.59 107 -212.52 2.157 T 10.0 3.000 35.560 to 120.0 0.0 10.000 -1.299 148 -212.52 -0.3080 0.0 13.000 -4.004 Vet = 18.66 148 0.0 2.157 T 10.0 29.000 30.257 to 120.0 0.0 10.000 0.0 149 -212.52 -0.3080 0.0 39.000 -12.011 Vet = 18.66 149 0.0 2.157 0.0 8.000 18.246 to 120.0 0.0 0.0 0.0 150 -212.52 -0.3080 0.0 8.000 -2.464 Vet = 18.66 150 100.11 2.157 0.0 8.000 15.782 K Factor = 25.20 to 120.0 0.0 0.0 0.0 151 -112.41 -0.0948 0.0 8.000 -0.758 Vel = 9.87 151 97.67 2.157 0.0 8.000 15.024 K Factor = 25.20 to 120.0 0.0 0.0 0.0 152 -14.74 -0.0022 0.0 8.000 -0.018 Vet = 1.29 152 97.62 2.157 0.0 8.000 15.006 K Factor = 25.20 to 120.0 0.0 0.0 0.0 153 82.88 0.0540 0.0 8.000 0.432 Vet = 7.28 153 99.02 2.157 0.0 8.000 15.438 K Factor = 25.20 to 120.0 0.0 0.0 0.0 154 181.9 0.2309 0.0 8.000 1.847 Vel = 15.97 154 0.0 2.157 T 10.0 66.960 17.285 to 120.0 0.0 10.000 0.0 155 181.9 0.2309 0.0 76.960 17.773 Vet = 15.97 155 0.0 2.157 T 10.0 3.000 35.058 to 120.0 0.0 10.000 1.299 100 181.9 0.2309 0.0 13.000 3.002 Vet = 15.97 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 10 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 181.90 39.359 KFactor= 28.99 108 -212.74 2.157 T 10.0 3.000 35.617 to 120.0 0.0 10.000 -1.299 156 -212.74 -0.3085 0.0 13.000 -4.011 Vel = 18.68 156 0.0 2.157 1 10.0 29.000 30.307 to 120.0 0.0 10.000 0.0 157 -212.74 -0.3086 0.0 39.000 -12.034 Vel = 18.68 157 0.0 2.157 0.0 8.000 18.273 to 120.0 0.0 0.0 0.0 158 -212.74 -0.3085 0.0 8.000 -2.468 Vel = 18.68 158 100.18 2.157 0.0 8.000 15.805 K Factor= 25.20 to 120.0 0.0 0.0 0.0 159 -112.56 -0.0951 0.0 8.000 -0.761 Vel = 9.88 159 97.74 2.157 0.0 8.000 15.044 K Factor = 25.20 to 120.0 0.0 0.0 0.0 160 -14.82 -0.0022 0.0 8.000 -0.018 Vel = 1.30 160 97.69 2.157 0.0 8.000 15.026 K Factor = 25.20 to 120.0 0.0 0.0 0.0 161 82.87 0.0540 0.0 8.000 0.432 Vel = 7.28 161 99.08 2.157 0.0 8.000 15.458 K Factor = 25.20 to 120.0 0.0 0.0 0.0 162 181.95 0.2310 0.0 8.000 1.848 Vel = 15.98 162 0.0 2.157 T 10.0 66.960 17.306 to 120.0 0.0 10.000 0.0 163 181.95 0.2310 0.0 76.960 17.781 Vel = 15.98 163 0.0 2.157 1 10.0 3.000 35.087 to 120.0 0.0 10.000 1.299 147 181.95 0.2311 0.0 13.000 3.004 Vel = 15.98 0.0 181.95 39.390 K Factor = 28.99 109 47.68 2.157 1 10.0 3.000 35.739 to 120.0 0.0 10.000 -1.299 164 47.68 0.0194 0.0 13.000 0.252 Vel = 4.19 164 0.0 2.157 2T 20.0 135.960 34.692 to 120.0 0.0 20.000 0.0 165 47.68 0.0194 0.0 155.960 3.025 Vel = 4.19 165 0.0 2.157 T 10.0 3.000 37.717 to 120.0 0.0 10.000 1.299 146 47.68 0.0195 0.0 13.000 0.253 Vel = 4.19 0.0 47.68 39.269 K Factor = 7.61 110 43.75 2.157 T 10.0 3.000 35.844 to 120.0 0.0 10.000 -1.299 166 43.75 0.0165 0.0 13.000 0.215 Vel = 3.84 166 0.0 2.157 2T 20.0 136.460 34.760 to 120.0 0.0 20.000 0.0 167 43.75 0.0165 0.0 156.460 2.588 Vel = 3.84 167 0.0 2.157 T 10.0 3.000 37.348 to 120.0 0.0 10.000 1.299 145 43.75 0.0166 0.0 13.000 0.216 Vel = 3.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 11 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 43.75 38.863 K Factor = 7.02 111 42.30 2.157 T 10.0 3.000 35.936 to 120.0 0.0 10.000 -1.299 168 42.3 0.0155 0.0 13.000 0.202 Vel = 3.71 168 0.0 2.157 2T 20.0 136.460 34.839 to 120.0 0.0 20.000 0.0 169 42.3 0.0155 0.0 156.460 2.431 Vel = 3.71 169 0.0 2.157 T 10.0 3.000 37.270 to 120.0 0.0 10.000 1.299 144 42.3 0.0155 0.0 13.000 0.202 Vel = 3.71 0.0 42.30 38.771 K Factor = 6.79 112 41.01 2.157 T 10.0 3.000 36.015 to 120.0 0.0 10.000 -1.299 170 41.01 0.0146 0.0 13.000 0.190 Vel = 3.60 170 0.0 2.157 2T 20.0 136.460 34.906 to 120.0 0.0 20.000 0.0 171 41.01 0.0147 0.0 156.460 2.296 Vel = 3.60 171 0.0 2.157 T 10.0 3.000 37.202 to 120.0 0.0 10.000 1.299 143 41.01 0.0147 0.0 13.000 0.191 Vel = 3.60 0.0 41.01 38.692 K Factor = 6.59 113 39.88 2.157 T 10.0 3.000 36.082 to 120.0 0.0 10.000 -1.299 172 39.88 0.0139 0.0 13.000 0.181 Vel = 3.50 172 0.0 2.157 2T 20.0 136.460 34.964 to 120.0 0.0 20.000 0.0 173 39.88 0.0139 0.0 156.460 2.181 Vel = 3.50 173 0.0 2.157 T 10.0 3.000 37.145 to 120.0 0.0 10.000 1.299 142 39.88 0.0139 0.0 13.000 0.181 Vel = 3.50 0.0 39.88 38.625 K Factor = 6.42 114 38.90 2.157 T 10.0 3.000 36.139 to 120.0 0.0 10.000 -1.299 174 38.9 0.0133 0.0 13.000 0.173 Vel = 3.42 174 0.0 2.157 2T 20.0 136.460 35.013 to 120.0 0.0 20.000 0.0 175 38.9 0.0133 0.0 156.460 2.083 Vel = 3.42 175 0.0 2.157 T 10.0 3.000 37.096 to 120.0 0.0 10.000 1.299 141 38.9 0.0133 0.0 13.000 0.173 Vel = 3.42 0.0 38.90 38.568 K Factor = 6.26 115 38.07 2.157 T 10.0 3.000 36.187 to 120.0 0.0 10.000 -1.299 176 38.07 0.0128 0.0 13.000 0.166 Vel = 3.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 12 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 176 0.0 2.157 2T 20.0 136.460 35.054 to 120.0 0.0 20.000 0.0 177 38.07 0.0128 0.0 156.460 2.001 Vel = 3.34 177 0.0 2.157 T 10.0 3.000 37.055 to 120.0 0.0 10.000 1.299 140 38.07 0.0128 0.0 13.000 0.166 Vel = 3.34 0.0 38.07 38.520 K Factor = 6.13 116 37.30 2.157 1 10.0 3.000 36.230 to 120.0 0.0 10.000 -1.299 178 37.3 0.0123 0.0 13.000 0.160 Vel = 3.27 178 0.0 2.157 21 20.0 136.460 35.091 to 120.0 0.0 20.000 0.0 179 37.3 0.0123 0.0 156.460 1.927 Vel = 3.27 179 0.0 2.157 T 10.0 3.000 37.018 to 120.0 0.0 10.000 1.299 139 37.3 0.0123 0.0 13.000 0.160 Vel = 3.27 0.0 37.30 38.477 K Factor = 6.01 117 36.67 2.157 1 10.0 3.000 36.265 to 120.0 0.0 10.000 -1.299 180 36.67 0.0119 0.0 13.000 0.155 Vel = 3.22 180 0.0 2.157 2T 20.0 136.460 35.121 to 120.0 0.0 20.000 0.0 181 36.67 0.0119 0.0 156.460 1.867 VeI= 3.22 181 0.0 2.157 1 10.0 3.000 36.988 to 120.0 0.0 10.000 1.299 138 36.67 0.0119 0.0 13.000 0.155 Vel = 3.22 0.0 36.67 38.442 K Factor = 5.91 118 36.16 2.157 T 10.0 3.000 36.292 to 120.0 0.0 10.000 -1.299 182 36.16 0.0116 0.0 13.000 0.151 Vel = 3.17 182 0.0 2.157 21 20.0 136.460 35.144 to 120.0 0.0 20.000 0.0 183 36.16 0.0116 0.0 156.460 1.820 Vel= 3.17 183 0.0 2.157 1 10.0 3.000 36.964 to 120.0 0.0 10.000 1.299 137 36.16 0.0117 0.0 13.000 0.152 Vel = 3.17 0.0 36.16 38.415 K Factor = 5.83 119 35.77 2.157 1 10.0 3.000 36.314 to 120.0 0.0 10.000 -1.299 184 35.77 0.0114 0.0 13.000 0.148 Vel = 3.14 184 0.0 2.157 21 20.0 136.460 35.163 to 120.0 0.0 20.000 0.0 185 35.77 0.0114 0.0 156.460 1.783 Vel = 3.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 13 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 185 0.0 2.157 1 10.0 3.000 36.946 to 120.0 0.0 10.000 1.299 136 35.77 0.0114 0.0 13.000 0.148 Vel= 3.14 0.0 35.77 38.393 K Factor = 5.77 120 35.48 2.157 T 10.0 3.000 36.330 to 120.0 0.0 10.000 -1.299 186 35.48 0.0112 0.0 13.000 0.145 Vet = 3.12 186 0.0 2.157 2T 20.0 136.460 35.176 to 120.0 0.0 20.000 0.0 187 35.48 0.0112 0.0 156.460 1.756 Vet = 3.12 187 0.0 2.157 T 10.0 3.000 36.932 to 120.0 0.0 10.000 1.299 135 35.48 0.0113 0.0 13.000 0.147 Vet = 3.12 0.0 35.48 38.378 K Factor = 5.73 121 35.27 2.157 1 10.0 3.000 36.340 to 120.0 0.0 10.000 -1.299 188 35.27 0.0112 0.0 13.000 0.145 Vet = 3.10 188 0.0 2.157 21 20.0 136.460 35.186 to 120.0 0.0 20.000 0.0 189 35.27 0.0111 0.0 156.460 1.737 Vet= 3.10 189 0.0 2.157 T 10.0 3.000 36.923 to 120.0 0.0 10.000 1.299 134 35.27 0.0112 0.0 13.000 0.145 Vet = 3.10 0.0 35.27 38.367 K Factor = 5.69 122 33.29 2.157 T 10.0 3.000 36.538 to 120.0 0.0 10.000 -1.299 190 33.29 0.0100 0.0 13.000 0.130 Vet = 2.92 190 0.0 2.157 21 20.0 136.460 35.369 to 120.0 0.0 20.000 0.0 191 33.29 0.0100 0.0 156.460 1.561 Vet = 2.92 191 0.0 2.157 1 10.0 3.000 36.930 to 120.0 0.0 10.000 1.299 133 33.29 0.0100 0.0 13.000 0.130 Vel = 2.92 0.0 33.29 38.359 K Factor = 5.38 123 32.10 2.157 1 10.0 3.000 36.652 to 120.0 0.0 10.000 -1.299 192 32.1 0.0093 0.0 13.000 0.121 Vet = 2.82 192 0.0 2.157 2T 20.0 136.460 35.474 to 120.0 0.0 20.000 0.0 193 32.1 0.0093 0.0 156.460 1.460 Vet = 2.82 193 0.0 2.157 T 10.0 3.000 36.934 to 120.0 0.0 10.000 1.299 132 32.1 0.0094 0.0 13.000 0.122 Vet = 2.82 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 14 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 32.10 38.355 K Factor = 5.18 124 32.06 2.157 1 10.0 3.000 36.654 to 120.0 0.0 10.000 -1.299 194 32.06 0.0093 0.0 13.000 0.121 Vel = 2.81 194 0.0 2.157 2T 20.0 136.460 35.476 to 120.0 0.0 20.000 0.0 195 32.06 0.0093 0.0 156.460 1.456 Vel = 2.81 195 0.0 2.157 T 10.0 3.000 36.932 to 120.0 0.0 10.000 1.299 131 32.06 0.0093 0.0 13.000 0.121 Vel = 2.81 0.0 32.06 38.352 K Factor = 5.18 125 32.05 2.157 T 10.0 3.000 36.655 to 120.0 0.0 10.000 -1.299 196 32.05 0.0093 0.0 13.000 0.121 Vel = 2.81 196 0.0 2.157 2T 20.0 136.460 35.477 to 120.0 0.0 20.000 0.0 197 32.05 0.0093 0.0 156.460 1.455 Vel= 2.81 197 0.0 2.157 T 10.0 3.000 36.932 to 120.0 0.0 10.000 1.299 130 32.05 0.0093 0.0 13.000 0.121 Vel = 2.81 0.0 32.05 38.352 K Factor = 5.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ... Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 19572 - Atec - Design TI & HilePile_FP design Building Location System Contract Data File 19572 - Atec - Design TI & HilePile_FP design AREA 1'EAST OF GRID Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 19572 - Atec - Design TI & HilePile_FP design Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 11.694 C2 - Residual Pressure: 95.8 D2 - System Flow :1182.98 C2 - Residual Flow : 6550 D2 - System Pressure : 78.619 Hose ( Demand) : 250 D3 - System Demand :1432.98 Safety Margin : 38.798 150 140 130 Cl 120 __ - - R 110 - - E 100 s 90 D2 580 u 70 R 60 E5° 40 30 20 10 Dr 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 2 19572 - Atec - Design TI & HilePile_FP design Date Fitting Legend Abbrev. Name B NFPA 13 Butterfly Valve E NFPA 13 90' Standard Elbow F NFPA 13 45 Elbow G NFPA 13 Gate Valve T NFPA 13 90' Flow thru Tee Zit Wilkins 950DA % % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with '. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 3 19572 - Atec - Design TI & HilePile_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 2 27.0 25.2 15.0 na 97.61 0.1 100 15.0 45 27.0 25.2 15.0 na 97.6 0.1 100 15.0 48 27.0 25.2 15.52 na 99.29 0.1 100 15.0 50 27.0 35.04 na 99 24.0 39.64 na 100 24.0 39.65 na 101 24.0 39.7 na TR1 24.0 54.73 na BR1 0.5 65.21 na BF1 -3.0 67.83 na BF2 -3.0 77.27 na UG1 -3.0 78.25 na TEST 0.0 78.62 na 250.0 102 27.0 25.2 15.65 na 99.69 0.1 100 15.0 103 27.0 17.91 na 104 27.0 20.17 na 105 27.0 31.19 na 106 24.0 36.16 na 107 24.0 36.17 na 108 24.0 36.23 na 109 24.0 36.34 na 110 24.0 36.43 na 111 24.0 36.52 na 112 24.0 36.59 na 113 24.0 36.65 na 114 24.0 36.7 na 115 24.0 36.75 na 116 24.0 36.79 na 117 24.0 36.82 na 118 24.0 36.85 na 119 24.0 36.87 na 120 24.0 36.88 na 121 24.0 36.89 na 122 24.0 37.07 na 123 24.0 37.18 na 124 24.0 37.18 na 130 24.0 38.74 na 131 24.0 38.74 na 132 24.0 38.74 na 133 24.0 38.74 na 134 24.0 38.75 na 135 24.0 38.76 na 136 24.0 38.77 na 137 24.0 38.79 na 138 24.0 38.82 na 139 24.0 38.85 na 140 24.0 38.89 na 141 24.0 38.93 na 142 24.0 38.99 na 143 24.0 39.05 na 144 24.0 39.12 na 145 24.0 39.2 na 146 24.0 39.58 na 147 24.0 39.69 na 148 27.0 31.2 na 149 27.0 20.18 na 150 27.0 17.92 na 151 27.0 25.2 15.66 na 99.71 0.1 100 15.0 152 27.0 25.2 15.01 na 97.63 0.1 100 15.0 153 27.0 25.2 15.01 na 97.62 0.1 100 15.0 154 27.0 25.2 15.53 na 99.31 0.1 100 15.0 155 27.0 35.06 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard TITAN FIRE PROTECTION, INC. Page 4 19572 - Atec - Design TI & HilePile_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 27.0 31.25 na 27.0 20.21 na 27.0 17.94 na 27.0 25.2 15.68 na 27.0 25.2 15.03 na 27.0 25.2 15.03 na 27.0 25.2 15.55 na 27.0 35.09 na 27.0 35.27 na 27.0 38.05 na 27.0 35.33 na 27.0 37.71 na 27.0 35.4 na 27.0 37.64 na 27.0 35.47 na 27.0 37.57 na 27.0 35.52 na 27.0 37.52 na 27.0 35.56 na 27.0 37.48 na 27.0 35.6 na 27.0 37.44 na 27.0 35.64 na 27.0 37.4 na 27.0 35.66 na 27.0 37.38 na 27.0 35.69 na 27.0 37.36 na 27.0 35.7 na 27.0 37.34 na 27.0 35.71 na 27.0 37.33 na 27.0 35.72 na 27.0 37.32 na 27.0 35.89 na 27.0 37.32 na 27.0 35.99 na 27.0 37.33 na 27.0 35.99 na 27.0 37.33 na 24.0 37.18 na 27.0 35.99 na 27.0 37.33 na 99.78 0.1 100 15.0 97.69 0.1 100 15.0 97.68 0.1 100 15.0 99.37 0.1 100 15.0 The maximum velocity is 17.83 and it occurs in the pipe between nodes 108 and 156 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 -5.54 2.157 0.0 8.000 15.003 K Factor = 25.20 to 120.0 0.0 0.0 0.0 45 -5.54 -0.0004 0.0 8.000 -0.003 Vel = 0.49 45 97.60 2.157 0.0 8.000 15.000 K Factor = 25.20 to 120.0 0.0 0.0 0.0 48 92.06 0.0655 0.0 8.000 0.524 Vel = 8.08 48 99.29 2.157 1 10.0 66.960 15.524 K Factor= 25.20 to 120.0 0.0 10.000 0.0 50 191.35 0.2536 0.0 76.960 19.519 Vel = 16.80 50 0.0 2.157 T 10.0 3.000 35.043 to 120.0 0.0 10.000 1.299 99 191.35 0.2537 0.0 13.000 3.298 Vel = 16.80 99 0.0 6.357 0.0 10.000 39.640 to 120.0 0.0 0.0 0.0 100 191.35 0.0013 0.0 10.000 0.013 Vel = 1.93 100 191.39 6.357 0.0 9.500 39.653 to 120.0 0.0 0.0 0.0 101 382.74 0.0047 0.0 9.500 0.045 Vel = 3.87 101 800.24 6.357 T 30.0 321.800 39.698 to 120.0 3E 42.0 72.000 0.0 TR1 1182.98 0.0382 0.0 393.800 15.035 Vel = 11.96 TR1 0.0 8.249 B 18.133 24.500 54.733 to 150.0 0.0 18.133 10.178 BR1 1182.98 0.0071 0.0 42.633 0.302 Vel = 7.10 BRI 0.0 7.68 E 27.199 82.540 65.213 to 150.0 0.0 27.199 1.516 BFI 1182.98 0.0101 0.0 109.739 1.104 Vel = 8.19 BF1 0.0 8.27 4E 95.76 12.000 67.833 to 140.0 Zit 0.0 95.760 8.581 * * Fixed Loss = 8.581 BF2 1182.98 0.0080 0.0 107.760 0.859 Vel = 7.07 BF2 0.0 7.68 T 52.887 44.040 77.273 to 150.0 0.0 52.887 0.0 UGI 1182.98 0.0101 0.0 96.927 0.975 Vel = 8.19 UG1 0.0 9.42 F 16.622 273.420 78.248 to 150.0 21 151.107 175.284 -1.299 TEST 1182.98 0.0037 G 7.555 448.704 1.670 Vel = 5.45 250.00 Qa = 250.00 1432.98 78.619 K Factor = 161.61 2 103.14 2.157 0.0 8.000 15.003 to 120.0 0.0 0.0 0.0 102 103.14 0.0809 0.0 8.000 0.647 Vel = 9.06 102 99.70 2.157 0.0 8.000 15.650 K Factor = 25.20 to 120.0 0.0 0.0 0.0 103 202.84 0.2825 0.0 8.000 2.260 Vel = 17.81 103 0.0 2.157 0.0 8.000 17.910 to 120.0 0.0 0.0 0.0 104 202.84 0.2825 0.0 8.000 2.260 Vel = 17.81 104 0.0 2.157 1 10.0 29.000 20.170 to 120.0 0.0 10.000 0.0 105 202.84 0.2825 0.0 39.000 11.017 Vel = 17.81 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 105 0.0 2.157 T 10.0 3.000 31.187 to 120.0 0.0 10.000 1.299 106 202.84 0.2825 0.0 13.000 3.673 Vel = 17.81 106 0.0 6.357 0.0 10.000 36.159 to 120.0 0.0 0.0 0.0 107 202.84 0.0015 0.0 10.000 0.015 Vel= 2.05 107 202.88 6.357 0.0 10.000 36.174 to 120.0 0.0 0.0 0.0 108 405.72 0.0052 0.0 10.000 0.052 Vel = 4.10 108 203.06 6.357 0.0 10.000 36.226 to 120.0 0.0 0.0 0.0 109 608.78 0.0112 0.0 10.000 0.112 Vel = 6.15 109 -45.51 6.357 0.0 10.000 36.338 to 120.0 0.0 0.0 0.0 110 563.27 0.0097 0.0 10.000 0.097 Vel = 5.69 110 -41.77 6.357 0.0 10.000 36.435 to 120.0 0.0 0.0 0.0 111 521.5 0.0084 0.0 10.000 0.084 Vel = 5.27 111 -40.37 6.357 0.0 10.000 36.519 to 120.0 0.0 0.0 0.0 112 481.13 0.0072 0.0 10.000 0.072 Vel = 4.86 112 -39.15 6.357 0.0 10.000 36.591 to 120.0 0.0 0.0 0.0 113 441.98 0.0062 0.0 10.000 0.062 Vel = 4.47 113 -38.07 6.357 0.0 10.000 36.653 to 120.0 0.0 0.0 0.0 114 403.91 0.0052 0.0 10.000 0.052 Vel = 4.08 114 -37.14 6.357 0.0 10.000 36.705 to 120.0 0.0 0.0 0.0 115 366.77 0.0044 0.0 10.000 0.044 Vel = 3.71 115 -36.34 6.357 0.0 11.000 36.749 to 120.0 0.0 0.0 0.0 116 330.43 0.0035 0.0 11.000 0.039 Vel = 3.34 116 -35.61 6.357 0.0 11.000 36.788 to 120.0 0.0 0.0 0.0 117 294.82 0.0030 0.0 11.000 0.033 Vel = 2.98 117 -35.01 6.357 0.0 11.000 36.821 to 120.0 0.0 0.0 0.0 118 259.81 0.0023 0.0 11.000 0.025 Vel = 2.63 118 -34.52 6.357 0.0 11.000 36.846 to 120.0 0.0 0.0 0.0 119 225.29 0.0018 0.0 11.000 0.020 Vel = 2.28 119 -34.14 6.357 0.0 11.000 36.866 to 120.0 0.0 0.0 0.0 120 191.15 0.0013 0.0 11.000 0.014 Vel = 1.93 120 -33.87 6.357 0.0 11.000 36.880 to 120.0 0.0 0.0 0.0 121 157.28 0.0009 0.0 11.000 0.010 Vel = 1.59 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 121 -33.67 3.26 0.0 12.000 36.890 to 120.0 0.0 0.0 0.0 122 123.61 0.0152 0.0 12.000 0.182 Vel = 4.75 122 -31.77 3.26 0.0 12.000 37.072 to 120.0 0.0 0.0 0.0 123 91.84 0.0087 0.0 12.000 0.104 Vel = 3.53 123 -30.65 6.357 0.0 12.000 37.176 to 120.0 0.0 0.0 0.0 124 61.19 0.0002 0.0 12.000 0.002 Vel = 0.62 124 -30.60 6.357 0.0 12.000 37.178 to 120.0 0.0 0.0 0.0 125 30.59 0.0001 0.0 12.000 0.001 Vel = 0.31 0.0 30.59 37.179 KFactor= 5.02 130 30.59 6.357 0.0 12.000 38.736 to 120.0 0.0 0.0 0.0 131 30.59 0.0 0.0 12.000 0.0 Vel = 0.31 131 30.60 6.357 0.0 12.000 38.736 to 120.0 0.0 0.0 0.0 132 61.19 0.0002 0.0 12.000 0.002 Vel = 0.62 132 30.65 6.357 0.0 12.000 38.738 to 120.0 0.0 0.0 0.0 133 91.84 0.0003 0.0 12.000 0.004 Vel = 0.93 133 31.77 6.357 0.0 12.000 38.742 to 120.0 0.0 0.0 0.0 134 123.61 0.0006 0.0 12.000 0.007 Vel = 1.25 134 33.67 6.357 0.0 11.000 38.749 to 120.0 0.0 0.0 0.0 135 157.28 0.0009 0.0 11.000 0.010 Vel = 1.59 135 33.87 6.357 0.0 11.000 38.759 to 120.0 0.0 0.0 0.0 136 191.15 0.0014 0.0 11.000 0.015 Vel = 1.93 136 34.14 6.357 0.0 11.000 38.774 to 120.0 0.0 0.0 0.0 137 225.29 0.0017 0.0 11.000 0.019 Vel = 2.28 137 34.52 6.357 0.0 11.000 38.793 to 120.0 0.0 0.0 0.0 138 259.81 0.0024 0.0 11.000 0.026 Vel = 2.63 138 35.01 6.357 0.0 11.000 38.819 to 120.0 0.0 0.0 0.0 139 294.82 0.0029 0.0 11.000 0.032 Vel = 2.98 139 35.61 6.357 0.0 11.000 38.851 to 120.0 0.0 0.0 0.0 140 330.43 0.0035 0.0 11.000 0.039 Vel = 3.34 140 36.34 6.357 0.0 10.000 38.890 to 120.0 0.0 0.0 0.0 141 366.77 0.0044 0.0 10.000 0.044 Vel = 3.71 141 37.14 6.357 0.0 10.000 38.934 to 120.0 0.0 0.0 0.0 142 403.91 0.0052 0.0 10.000 0.052 Vel = 4.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c'.or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 142 38.07 6.357 0.0 10.000 38.986 to 120.0 0.0 0.0 0.0 143 441.98 0.0062 0.0 10.000 0.062 Vel = 4.47 143 39.15 6.357 0.0 10.000 39.048 to 120.0 0.0 0.0 0.0 144 481.13 0.0073 0.0 10.000 0.073 Vel= 4.86 144 40.37 6.357 0.0 10.000 39.121 to 120.0 0.0 0.0 0.0 145 521.5 0.0083 0.0 10.000 0.083 Vel = 5.27 145 41.77 6.357 2E 28.0 10.500 39.204 to 120.0 0.0 28.000 0.0 146 563.27 0.0097 0.0 38.500 0.373 Vel = 5.69 146 45.51 6.357 0.0 10.000 39.577 to 120.0 0.0 0.0 0.0 147 608.78 0.0112 0.0 10.000 0.112 Vel = 6.15 147 191.46 6.357 0.0 0.500 39.689 to 120.0 0.0 0.0 0.0 101 800.24 0.0180 0.0 0.500 0.009 Vel = 8.09 0.0 800.24 39.698 K Factor = 127.01 107 -202.88 2.157 T 10.0 3.000 36.174 to 120.0 0.0 10.000 -1.299 148 -202.88 -0.2827 0.0 13.000 -3.675 Vel = 17.81 148 0.0 2.157 T 10.0 29.000 31.200 to 120.0 0.0 10.000 0.0 149 -202.88 -0.2826 0.0 39.000 -11.022 Vel = 17.81 149 0.0 2.157 0.0 8.000 20.178 to 120.0 0.0 0.0 0.0 150 -202.88 -0.2826 0.0 8.000 -2.261 Vel = 17.81 150 0.0 2.157 0.0 8.000 17.917 to 120.0 0.0 0.0 0.0 151 -202.88 -0.2826 0.0 8.000 -2.261 Vel = 17.81 151 99.71 2.157 0.0 8.000 15.656 K Factor = 25.20 to 120.0 0.0 0.0 0.0 152 -103.17 -0.0809 0.0 8.000 -0.647 Vel = 9.06 152 97.63 2.157 0.0 8.000 15.009 K Factor= 25.20 to 120.0 0.0 0.0 0.0 153 -5.54 -0.0004 0.0 8.000 -0.003 Vel = 0.49 153 97.62 2.157 0.0 8.000 15.006 K Factor = 25.20 to 120.0 0.0 0.0 0.0 154 92.08 0.0655 0.0 8.000 0.524 Vel = 8.08 154 99.30 2.157 T 10.0 66.960 15.530 K Factor= 25.20 to 120.0 0.0 10.000 0.0 155 191.38 0.2537 0.0 76.960 19.526 Vel = 16.80 155 0.0 2.157 T 10.0 3.000 35.056 to 120.0 0.0 10.000 1.299 100 191.38 0.2537 0.0 13.000 3.298 Vel = 16.80 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 9 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 191.38 39.653 K Factor = 30.39 108 -203.06 2.157 T 10.0 3.000 36.226 to 120.0 0.0 10.000 -1.299 156 -203.06 -0.2831 0.0 13.000 -3.680 Vel = 17.83 156 0.0 2.157 T 10.0 29.000 31.247 to 120.0 0.0 10.000 0.0 157 -203.06 -0.2831 0.0 39.000 -11.041 Vel = 17.83 157 0.0 2.157 0.0 8.000 20.206 to 120.0 0.0 0.0 0.0 158 -203.06 -0.2830 0.0 8.000 -2.264 Vel = 17.83 158 0.0 2.157 0.0 8.000 17.942 to 120.0 0.0 0.0 0.0 159 -203.06 -0.2831 0.0 8.000 -2.265 Vel = 17.83 159 99.77 2.157 0.0 8.000 15.677 K Factor= 25.20 to 120.0 0.0 0.0 0.0 160 -103.29 -0.0811 0.0 8.000 -0.649 Vel = 9.07 160 97.69 2.157 0.0 8.000 15.028 K Factor= 25.20 to 120.0 0.0 0.0 0.0 161 -5.6 -0.0004 0.0 8.000 -0.003 Vel = 0.49 161 97.69 2.157 0.0 8.000 15.025 K Factor = 25.20 to 120.0 0.0 0.0 0.0 162 92.09 0.0656 0.0 8.000 0.525 Vel = 8.09 162 99.37 2.157 T 10.0 66.960 15.550 K Factor = 25.20 to 120.0 0.0 10.000 0.0 163 191.46 0.2539 0.0 76.960 19.539 Vel = 16.81 163 0.0 2.157 T 10.0 3.000 35.089 to 120.0 0.0 10.000 1.299 147 191.46 0.2539 0.0 13.000 3.301 Vel = 16.81 0.0 191.46 39.689 K Factor = 30.39 109 45.52 2.157 1 10.0 3.000 36.338 to 120.0 0.0 10.000 -1.299 164 45.52 0.0178 0.0 13.000 0.231 Vel = 4.00 164 0.0 2.157 2T 20.0 135.960 35.270 to 120.0 0.0 20.000 0.0 165 45.52 0.0178 0.0 155.960 2.776 Vel = 4.00 165 0.0 2.157 T 10.0 3.000 38.046 to 120.0 0.0 10.000 1.299 146 45.52 0.0178 0.0 13.000 0.232 Vel = 4.00 0.0 45.52 39.577 K Factor = 7.24 110 41.76 2.157 T 10.0 3.000 36.435 to 120.0 0.0 10.000 -1.299 166 41.76 0.0152 0.0 13.000 0.197 Vel = 3.67 166 0.0 2.157 2T 20.0 136.460 35.333 to 120.0 0.0 20.000 0.0 167 41.76 0.0152 0.0 156.460 2.375 Vel = 3.67 167 0.0 2.157 T 10.0 3.000 37.708 to 120.0 0.0 10.000 1.299 145 41.76 0.0152 0.0 13.000 0.197 Vel = 3.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 10 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 41.76 39.204 K Factor = 6.67 111 40.38 2.157 T 10.0 3.000 36.519 to 120.0 0.0 10.000 -1.299 168 40.38 0.0142 0.0 13.000 0.185 Vel = 3.55 168 0.0 2.157 2T 20.0 136.460 35.405 to 120.0 0.0 20.000 0.0 169 40.38 0.0143 0.0 156.460 2.231 Vel = 3.55 169 0.0 2.157 T 10.0 3.000 37.636 to 120.0 0.0 10.000 1.299 144 40.38 0.0143 0.0 13.000 0.186 Vel = 3.55 0.0 40.38 39.121 K Factor = 6.46 112 39.15 2.157 T 10.0 3.000 36.591 to 120.0 0.0 10.000 -1.299 170 39.15 0.0135 0.0 13.000 0.175 Vel = 3.44 170 0.0 2.157 2T 20.0 136.460 35.467 to 120.0 0.0 20.000 0.0 171 39.15 0.0135 0.0 156.460 2.107 Vel = 3.44 171 0.0 2.157 T 10.0 3.000 37.574 to 120.0 0.0 10.000 1.299 143 39.15 0.0135 0.0 13.000 0.175 Vel = 3.44 0.0 39.15 39.048 K Factor= 6.27 113 38.07 2.157 1 10.0 3.000 36.653 to 120.0 0.0 10.000 -1.299 172 38.07 0.0128 0.0 13.000 0.166 Vel= 3.34 172 0.0 2.157 2T 20.0 136.460 35.520 to 120.0 0.0 20.000 0.0 173 38.07 0.0128 0.0 156.460 2.001 Vel = 3.34 173 0.0 2.157 T 10.0 3.000 37.521 to 120.0 0.0 10.000 1.299 142 38.07 0.0128 0.0 13.000 0.166 Vel = 3.34 0.0 38.07 38.986 K Factor = 6.10 114 37.14 2.157 1 10.0 3.000 36.705 to 120.0 0.0 10.000 -1.299 174 37.14 0.0122 0.0 13.000 0.158 Vel = 3.26 174 0.0 2.157 2T 20.0 136.460 35.564 to 120.0 0.0 20.000 0.0 175 37.14 0.0122 0.0 156.460 1.912 Vel = 3.26 175 0.0 2.157 T 10.0 3.000 37.476 to 120.0 0.0 10.000 1.299 141 37.14 0.0122 0.0 13.000 0.159 Vel = 3.26 0.0 37.14 38.934 K Factor = 5.95 115 36.34 2.157 T 10.0 3.000 36.749 to 120.0 0.0 10.000 -1.299 176 36.34 0.0117 0.0 13.000 0.152 Vel = 3.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 11 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 176 0.0 2.157 2T 20.0 136.460 35.602 to 120.0 0.0 20.000 0.0 177 36.34 0.0117 0.0 156.460 1.837 Vel = 3.19 177 0.0 2.157 T 10.0 3.000 37.439 to 120.0 0.0 10.000 1.299 140 36.34 0.0117 0.0 13.000 0.152 Vel = 3.19 0.0 36.34 38.890 K Factor = 5.83 116 35.61 2.157 T 10.0 3.000 36.788 to 120.0 0.0 10.000 -1.299 178 35.61 0.0113 0.0 13.000 0.147 Vel = 3.13 178 0.0 2.157 2T 20.0 136.460 35.636 to 120.0 0.0 20.000 0.0 179 35.61 0.0113 0.0 156.460 1.769 Vel = 3.13 179 0.0 2.157 T 10.0 3.000 37.405 to 120.0 0.0 10.000 1.299 139 35.61 0.0113 0.0 13.000 0.147 Vel = 3.13 0.0 35.61 38.851 K Factor = 5.71 117 35.01 2.157 T 10.0 3.000 36.821 to 120.0 0.0 10.000 -1.299 180 35.01 0.0109 0.0 13.000 0.142 Vel = 3.07 180 0.0 2.157 21 20.0 136.460 35.664 to 120.0 0.0 20.000 0.0 181 35.01 0.0109 0.0 156.460 1.713 Vel = 3.07 181 0.0 2.157 T 10.0 3.000 37.377 to 120.0 0.0 10.000 1.299 138 35.01 0.0110 0.0 13.000 0.143 Vel= 3.07 0.0 35.01 38.819 KFactor= 5.62 118 34.52 2.157 1 10.0 3.000 36.846 to 120.0 0.0 10.000 -1.299 182 34.52 0.0106 0.0 13.000 0.138 Vel = 3.03 182 0.0 2.157 21 20.0 136.460 35.685 to 120.0 0.0 20.000 0.0 183 34.52 0.0107 0.0 156.460 1.670 Vel = 3.03 183 0.0 2.157 1 10.0 3.000 37.355 to 120.0 0.0 10.000 1.299 137 34.52 0.0107 0.0 13.000 0.139 Vel = 3.03 0.0 34.52 38.793 K Factor= 5.54 119 34.14 2.157 T 10.0 3.000 36.866 to 120.0 0.0 10.000 -1.299 184 34.14 0.0104 0.0 13.000 0.135 Vel = 3.00 184 0.0 2.157 2T 20.0 136.460 35.702 to 120.0 0.0 20.000 0.0 185 34.14 0.0105 0.0 156.460 1.636 Vel = 3.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 12 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 185 0.0 2.157 T 10.0 3.000 37.338 to 120.0 0.0 10.000 1.299 136 34.14 0.0105 0.0 13.000 0.137 Vel = 3.00 0.0 34.14 38.774 K Factor = 5.48 120 33.86 2.157 T 10.0 3.000 36.880 to 120.0 0.0 10.000 -1.299 186 33.86 0.0102 0.0 13.000 0.133 Vel = 2.97 186 0.0 2.157 21 20.0 136.460 35.714 to 120.0 0.0 20.000 0.0 187 33.86 0.0103 0.0 156.460 1.612 Vel = 2.97 187 0.0 2.157 1 10.0 3.000 37.326 to 120.0 0.0 10.000 1.299 135 33.86 0.0103 0.0 13.000 0.134 Vel = 2.97 0.0 33.86 38.759 K Factor = 5.44 121 33.67 2.157 1 10.0 3.000 36.890 to 120.0 0.0 10.000 -1.299 188 33.67 0.0102 0.0 13.000 0.132 Vel = 2.96 188 0.0 2.157 2T 20.0 136.460 35.723 to 120.0 0.0 20.000 0.0 189 33.67 0.0102 0.0 156.460 1.595 Vel = 2.96 189 0.0 2.157 T 10.0 3.000 37.318 to 120.0 0.0 10.000 1.299 134 33.67 0.0102 0.0 13.000 0.132 Vel = 2.96 0.0 33.67 38.749 K Factor = 5.41 122 31.78 2.157 T 10.0 3.000 37.072 to 120.0 0.0 10.000 -1.299 190 31.78 0.0091 0.0 13.000 0.118 Vel = 2.79 190 0.0 2.157 2T 20.0 136.460 35.891 to 120.0 0.0 20.000 0.0 191 31.78 0.0092 0.0 156.460 1.433 Vel = 2.79 191 0.0 2.157 T 10.0 3.000 37.324 to 120.0 0.0 10.000 1.299 133 31.78 0.0092 0.0 13.000 0.119 Vel = 2.79 0.0 31.78 38.742 KFactor= 5.11 123 30.64 2.157 T 10.0 3.000 37.176 to 120.0 0.0 10.000 -1.299 192 30.64 0.0085 0.0 13.000 0.111 Vel = 2.69 192 0.0 2.157 2T 20.0 136.460 35.988 to 120.0 0.0 20.000 0.0 193 30.64 0.0086 0.0 156.460 1.340 Vel = 2.69 193 0.0 2.157 1 10.0 3.000 37.328 to 120.0 0.0 10.000 1.299 132 30.64 0.0085 0.0 13.000 0.111 Vel = 2.69 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 13 19572 - Atec - Design TI & HilePile FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pc Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 30.64 38.738 K Factor = 4.92 124 30.60 2.157 1 10.0 3.000 37.178 to 120.0 0.0 10.000 -1.299 194 30.6 0.0085 0.0 13.000 0.111 Vel = 2.69 194 0.0 2.157 21 20.0 136.460 35.990 to 120.0 0.0 20.000 0.0 195 30.6 0.0085 0.0 156.460 1.336 Vel = 2.69 195 0.0 2.157 T 10.0 3.000 37.326 to 120.0 0.0 10.000 1.299 131 30.6 0.0085 0.0 13.000 0.111 Vel = 2.69 0.0 30.60 38.736 K Factor = 4.92 125 30.59 2.157 T 10.0 3.000 37.179 to 120.0 0.0 10.000 -1.299 196 30.59 0.0085 0.0 13.000 0.110 Vel = 2.69 196 0.0 2.157 21 20.0 136.460 35.990 to 120.0 0.0 20.000 0.0 197 30.59 0.0085 0.0 156.460 1.336 Vel = 2.69 197 0.0 2.157 T 10.0 3.000 37.326 to 120.0 0.0 10.000 1.299 130 30.59 0.0085 0.0 13.000 0.111 Vel = 2.69 0.0 30.59 - 38.736 K Factor = 4.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F I .~W.i ~11 q ... Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 19572 - Atec - Design TI & HilePile_FP design Building Location System Contract Data File : 19572 - Atec - Design TI & HilePile_FP design AREA iWEST OF GRID Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 19572 - Atec - Design TI & HilePile_FP design Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 11.694 C2 - Residual Pressure: 95.8 D2 - System Flow :1184.31 C2 - Residual Flow : 6550 D2 - System Pressure : 77.788 Hose ( Demand) : 250 D3 - System Demand :1434.31 Safety Margin : 39.626 150 140 -- 130 -- Cl l2O : R 110 E 100 __ 590 D2 s 80 - U70 R6° E5° 40 30 20 10 --Dl- • 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 2 19572 - Atec - Design TI & HilePile_FP design Date Fitting Legend Abbrev. Name % ~ 1 11/4 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zit Wilkins 950DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 3 19572 - Atec - Design TI & HilePile_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 2 27.0 25.2 15.35 na 98.72 0.1 100 15.0 45 27.0 17.02 na 48 27.0 18.69 na 50 27.0 34.76 na 99 24.0 38.78 na 100 24.0 38.79 na 101 24.0 38.82 na TR1 24.0 53.89 na BR1 0.5 64.37 na BF1 -3.0 66.99 na BF2 -3.0 76.44 na UG1 -3.0 77.41 na TEST 0.0 77.79 na 250.0 102 27.0 25.2 15.0 na 97.6 0.1 100 15.0 103 27.0 25.2 15.04 na 97.74 0.1 100 15.0 104 27.0 25.2 15.92 na 100.56 0.1 100 15.0 105 27.0 28.98 na 106 24.0 34.63 na 107 24.0 34.65 na 108 24.0 34.71 na 109 24.0 34.84 na 110 24.0 34.96 na 111 24.0 35.06 na 112 24.0 35.14 na 113 24.0 35.22 na 114 24.0 35.28 na 115 24.0 35.33 na 116 24.0 35.38 na 117 24.0 35.41 na 118 24.0 35.44 na 119 24.0 35.47 na 120 24.0 35.49 na 121 24.0 35.5 na 122 24.0 35.71 na 123 24.0 35.84 na 124 24.0 35.84 na 130 24.0 37.68 na 131 24.0 37.69 na 132 24.0 37.69 na 133 24.0 37.69 na 134 24.0 37.7 na 135 24.0 37.71 na 136 24.0 37.73 na 137 24.0 37.75 na 138 24.0 37.78 na 139 24.0 37.82 na 140 24.0 37.87 na 141 24.0 37.92 na 142 24.0 37.98 na 143 24.0 38.06 na 144 24.0 38.14 na 145 24.0 38.24 na 146 24.0 38.68 na 147 24.0 38.81 na 148 27.0 28.99 na 149 27.0 25.2 15.93 na 100.58 0.1 100 15.0 150 27.0 25.2 15.05 na 97.76 0.1 100 15.0 151 27.0 25.2 15.01 na 97.62 0.1 100 15.0 152 27.0 25.2 15.35 na 98.74 0.1 100 15.0 153 27.0 17.02 na 154 27.0 18.7 na 155 27.0 34.77 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard TITAN FIRE PROTECTION, INC. Page 4 19572 - Atec - Design TI & HilePile_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 27.0 29.05 na 27.0 25.2 15.95 na 27.0 25.2 15.07 na 27.0 25.2 15.03 na 27.0 25.2 15.37 na 27.0 17.05 na 27.0 18.72 na 27.0 34.8 na 27.0 33.82 na 27.0 37.11 na 27.0 33.89 na 27.0 36.71 na 27.0 33.98 na 27.0 36.62 na 27.0 34.05 na 27.0 36.55 na 27.0 34.11 na 27.0 36.49 na 27.0 34.17 na 27.0 36.43 na 27.0 34.21 na 27.0 36.39 na 27.0 34.25 na 27.0 36.35 na 27.0 34.28 na 27.0 36.32 na 27.0 34.31 na 27.0 36.29 na 27.0 34.33 na 27.0 36.27 na 27.0 34.34 na 27.0 36.25 na 27.0 34.35 na 27.0 36.24 na 27.0 34.55 na 27.0 36.25 na 27.0 34.67 na 27.0 36.26 na 27.0 34.67 na 27.0 36.25 na 24.0 35.84 na 27.0 34.67 na 27.0 36.25 na 100.66 0.1 100 15.0 97.83 0.1 100 15.0 97.69 0.1 100 15.0 98.81 0.1 100 15.0 The maximum velocity is 19.55 and it occurs in the pipe between nodes 108 and 156 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 172.29 2.157 0.0 8.000 15.346 K Factor = 25.20 to 120.0 0.0 0.0 0.0 45 172.29 0.2089 0.0 8.000 1.671 Vel = 15.13 45 0.0 2.157 0.0 8.000 17.017 to 120.0 0.0 0.0 0.0 48 172.29 0.2089 0.0 8.000 1.671 Vel = 15.13 48 0.0 2.157 T 10.0 66.960 18.688 to 120.0 0.0 10.000 0.0 50 172.29 0.2089 0.0 76.960 16.074 Vel = 15.13 50 0.0 2.157 T 10.0 3.000 34.762 to 120.0 0.0 10.000 1.299 99 172.29 0.2089 0.0 13.000 2.716 Vel = 15.13 99 0.0 6.357 0.0 10.000 38.777 to 120.0 0.0 0.0 0.0 100 172.29 0.0011 0.0 10.000 0.011 Vel = 1.74 100 172.30 6.357 0.0 9.500 38.788 to 120.0 0.0 0.0 0.0 101 344.59 0.0039 0.0 9.500 0.037 Vel = 3.48 101 839.72 6.357 T 30.0 321.800 38.825 to 120.0 3E 42.0 72.000 0.0 TR1 1184.31 0.0383 0.0 393.800 15.066 Vel = 11.97 TR1 0.0 8.249 B 18.133 24.500 53.891 to 150.0 0.0 18.133 10.178 BR1 1184.31 0.0071 0.0 42.633 0.303 Vel = 7.11 BRI 0.0 7.68 E 27.199 82.540 64.372 to 150.0 0.0 27.199 1.516 BF1 1184.31 0.0101 0.0 109.739 1.106 Vel = 8.20 BF1 0.0 8.27 4E 95.76 12.000 66.994 to 140.0 Zit 0.0 95.760 8.582 * * Fixed Loss = 8.582 BF2 1184.31 0.0080 0.0 107.760 0.861 Vel = 7.07 BF2 0.0 7.68 T 52.887 44.040 76.437 to 150.0 0.0 52.887 0.0 UGI 1184.31 0.0101 0.0 96.927 0.977 Vel = 8.20 UGI 0.0 9.42 F 16.622 273.420 77.414 to 150.0 2T 151.107 175.284 -1.299 TEST 1184.31 0.0037 G 7.555 448.704 1.673 Vel = 5.45 250.00 Qa = 250.00 1434.31 77.788 K Factor = 162.62 2 -73.57 2.157 0.0 8.000 15.346 to 120.0 0.0 0.0 0.0 102 -73.57 -0.0432 0.0 8.000 -0.346 Vel = 6.46 102 97.60 2.157 0.0 8.000 15.000 K Factor = 25.20 to 120.0 0.0 0.0 0.0 103 24.03 0.0055 0.0 8.000 0.044 Vel = 2.11 103 97.74 2.157 0.0 8.000 15.044 K Factor = 25.20 to 120.0 0.0 0.0 0.0 104 121.77 0.1099 0.0 8.000 0.879 Vel= 10.69 104 100.56 2.157 T 10.0 29.000 15.923 K Factor = 25.20 to 120.0 0.0 10.000 0.0 105 222.33 0.3348 0.0 39.000 13.056 Vel = 19.52 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 105 0.0 2.157 T 10.0 3.000 28.979 to 120.0 0.0 10.000 1.299 106 222.33 0.3348 0.0 13.000 4.353 Vel = 19.52 106 0.0 6.357 0.0 10.000 34.631 to 120.0 0.0 0.0 0.0 107 222.33 0.0017 0.0 10.000 0.017 Vel = 2.25 107 222.40 6.357 0.0 10.000 34.648 to 120.0 0.0 0.0 0.0 108 444.73 0.0062 0.0 10.000 0.062 Vel = 4.50 108 222.66 6.357 0.0 10.000 34.710 to 120.0 0.0 0.0 0.0 109 667.39 0.0133 0.0 10.000 0.133 Vel = 6.75 109 -49.90 6.357 0.0 10.000 34.843 to 120.0 0.0 0.0 0.0 110 617.49 0.0115 0.0 10.000 0.115 Vel= 6.24 110 -45.78 6.357 0.0 10.000 34.958 to 120.0 0.0 0.0 0.0 111 571.71 0.0099 0.0 10.000 0.099 Vel = 5.78 111 -44.26 6.357 0.0 10.000 35.057 to 120.0 0.0 0.0 0.0 112 527.45 0.0086 0.0 10.000 0.086 Vel = 5.33 112 -42.92 6.357 0.0 10.000 35.143 to 120.0 0.0 0.0 0.0 113 484.53 0.0073 0.0 10.000 0.073 Vel = 4.90 113 -41.73 6.357 0.0 10.000 35.216 to 120.0 0.0 0.0 0.0 114 442.8 0.0062 0.0 10.000 0.062 Vel = 4.48 114 -40.72 6.357 0.0 10.000 35.278 to 120.0 0.0 0.0 0.0 115 402.08 0.0052 0.0 10.000 0.052 Vel = 4.06 115 -39.84 6.357 0.0 11.000 35.330 to 120.0 0.0 0.0 0.0 116 362.24 0.0043 0.0 11.000 0.047 Vel= 3.66 116 -39.04 6.357 0.0 11.000 35.377 to 120.0 0.0 0.0 0.0 117 323.2 0.0035 0.0 11.000 0.038 Vel = 3.27 117 -38.37 6.357 0.0 11.000 35.415 to 120.0 0.0 0.0 0.0 118 284.83 0.0027 0.0 11.000 0.030 Vel = 2.88 118 -37.85 6.357 0.0 11.000 35.445 to 120.0 0.0 0.0 0.0 119 246.98 0.0021 0.0 11.000 0.023 Vel = 2.50 119 -37.43 6.357 0.0 11.000 35.468 to 120.0 0.0 0.0 0.0 120 209.55 0.0015 0.0 11.000 0.017 Vel = 2.12 120 -37.12 6.357 0.0 11.000 35.485 to 120.0 0.0 0.0 0.0 121 172.43 0.0011 0.0 11.000 0.012 Vel = 1.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 121 -36.92 3.26 0.0 12.000 35.497 to 120.0 0.0 0.0 0.0 122 135.51 0.0179 0.0 12.000 0.215 Vel = 5.21 122 -34.83 3.26 0.0 12.000 35.712 to 120.0 0.0 0.0 0.0 123 100.68 0.0103 0.0 12.000 0.124 Vel = 3.87 123 -33.60 6.357 0.0 12.000 35.836 to 120.0 0.0 0.0 0.0 124 67.08 0.0002 0.0 12.000 0.003 Vel = 0.68 124 -33.54 6.357 0.0 12.000 35.839 to 120.0 0.0 0.0 0.0 125 33.54 0.0 0.0 12.000 0.0 Vel = 0.34 0.0 33.54 35.839 K Factor = 5.60 130 33.54 6.357 0.0 12.000 37.685 to 120.0 0.0 0.0 0.0 131 33.54 0.0001 0.0 12.000 0.001 Vel = 0.34 131 33.54 6.357 0.0 12.000 37.686 to 120.0 0.0 0.0 0.0 132 67.08 0.0002 0.0 12.000 0.002 Vel = 0.68 132 33.60 6.357 0.0 12.000 37.688 to 120.0 0.0 0.0 0.0 133 100.68 0.0004 0.0 12.000 0.005 Vel = 1.02 133 34.83 6.357 0.0 12.000 37.693 to 120.0 0.0 0.0 0.0 134 135.51 0.0007 0.0 12.000 0.008 Vel = 1.37 134 36.92 6.357 0.0 11.000 37.701 to 120.0 0.0 0.0 0.0 135 172.43 0.0011 0.0 11.000 0.012 Vel = 1.74 135 37.12 6.357 0.0 11.000 37.713 to 120.0 0.0 0.0 0.0 136 209.55 0.0015 0.0 11.000 0.017 Vel = 2.12 136 37.43 6.357 0.0 11.000 37.730 to 120.0 0.0 0.0 0.0 137 246.98 0.0021 0.0 11.000 0.023 Vel = 2.50 137 37.85 6.357 0.0 11.000 37.753 to 120.0 0.0 0.0 0.0 138 284.83 0.0027 0.0 11.000 0.030 Vel = 2.88 138 38.37 6.357 0.0 11.000 37.783 to 120.0 0.0 0.0 0.0 139 323.2 0.0035 0.0 11.000 0.038 Vel = 3.27 139 39.04 6.357 0.0 11.000 37.821 to 120.0 0.0 0.0 0.0 140 362.24 0.0043 0.0 11.000 0.047 Vel = 3.66 140 39.84 6.357 0.0 10.000 37.868 to 120.0 0.0 0.0 0.0 141 402.08 0.0052 0.0 10.000 0.052 Vel = 4.06 141 40.72 6.357 0.0 10.000 37.920 to 120.0 0.0 0.0 0.0 142 442.8 0.0062 0.0 10.000 0.062 Vel = 4.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. . Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 142 41.73 6.357 0.0 10.000 37.982 to 120.0 0.0 0.0 0.0 143 484.53 0.0073 0.0 10.000 0.073 Vel = 4.90 143 42.92 6.357 0.0 10.000 38.055 to 120.0 0.0 0.0 0.0 144 527.45 0.0086 0.0 10.000 0.086 Vel = 5.33 144 44.26 6.357 0.0 10.000 38.141 to 120.0 0.0 0.0 0.0 145 571.71 0.0099 0.0 10.000 0.099 Vel = 5.78 145 45.78 6.357 2E 28.0 10.500 38.240 to 120.0 0.0 28.000 0.0 146 617.49 0.0115 0.0 38.500 0.442 Vel= 6.24 146 49.90 6.357 0.0 10.000 38.682 to 120.0 0.0 0.0 0.0 147 667.39 0.0132 0.0 10.000 0.132 Vel = 6.75 147 172.33 6.357 0.0 0.500 38.814 to 120.0 0.0 0.0 0.0 101 839.72 0.0220 0.0 0.500 0.011 Vel = 8.49 0.0 839.72 38.825 K Factor = 134.77 107 -222.40 2.157 T 10.0 3.000 34.648 to 120.0 0.0 10.000 -1.299 148 -222.4 -0.3350 0.0 13.000 -4.355 Vel = 19.53 148 0.0 2.157 T 10.0 29.000 28.994 to 120.0 0.0 10.000 0.0 149 -222.4 -0.3350 0.0 39.000 -13.064 Vel = 19.53 149 100.58 2.157 0.0 8.000 15.930 K Factor = 25.20 to 120.0 0.0 0.0 0.0 150 -121.82 -0.1100 0.0 8.000 -0.880 Vel = 10.70 150 97.76 2.157 0.0 8.000 15.050 K Factor = 25.20 to 120.0 0.0 0.0 0.0 151 -24.06 -0.0054 0.0 8.000 -0.043 Vel = 2.11 151 97.62 2.157 0.0 8.000 15.007 K Factor = 25.20 to 120.0 0.0 0.0 0.0 152 73.56 0.0432 0.0 8.000 0.346 Vel = 6.46 152 98.74 2.157 0.0 8.000 15.353 K Factor = 25.20 to 120.0 0.0 0.0 0.0 153 172.3 0.2089 0.0 8.000 1.671 Vel = 15.13 153 0.0 2.157 0.0 8.000 17.024 to 120.0 0.0 0.0 0.0 154 172.3 0.2089 0.0 8.000 1.671 Vel = 15.13 154 0.0 2.157 T 10.0 66.960 18.695 to 120.0 0.0 10.000 0.0 155 172.3 0.2089 0.0 76.960 16.077 Vel = 15.13 155 0.0 2.157 T 10.0 3.000 34.772 to 120.0 0.0 10.000 1.299 100 172.3 0.2090 0.0 13.000 2.717 Vel = 15.13 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 9 19572 - Atec - Design TI & HilePile FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C', or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 172.30 38.788 KFactor= 27.67 108 -222.66 2.157 T 10.0 3.000 34.710 to 120.0 0.0 10.000 -1.299 156 -222.66 -0.3357 0.0 13.000 -4.364 Vel = 19.55 156 0.0 2.157 T 10.0 29.000 29.047 to 120.0 0.0 10.000 0.0 157 -222.66 -0.3357 0.0 39.000 -13.092 Vel = 19.55 157 100.66 2.157 0.0 8.000 15.955 K Factor = 25.20 to 120.0 0.0 0.0 0.0 158 -122.0 -0.1104 0.0 8.000 -0.883 Vel = 10.71 158 97.83 2.157 0.0 8.000 15.072 K Factor = 25.20 to 120.0 0.0 0.0 0.0 159 -24.17 -0.0055 0.0 8.000 -0.044 Vel = 2.12 159 97.69 2.157 0.0 8.000 15.028 K Factor = 25.20 to 120.0 0.0 0.0 0.0 160 73.52 0.0432 0.0 8.000 0.346 Vel = 6.45 160 98.81 2.157 0.0 8.000 15.374 K Factor = 25.20 to 120.0 0.0 0.0 0.0 161 172.33 0.2090 0.0 8.000 1.672 Vel = 15.13 161 0.0 2.157 0.0 8.000 17.046 to 120.0 0.0 0.0 0.0 162 172.33 0.2089 0.0 8.000 1.671 Vel = 15.13 162 0.0 2.157 T 10.0 66.960 18.717 to 120.0 0.0 10.000 0.0 163 172.33 0.2090 0.0 76.960 16.082 Vel = 15.13 163 0.0 2.157 T 10.0 3.000 34.799 to 120.0 0.0 10.000 1.299 147 172.33 0.2089 0.0 13.000 2.716 Vel = 15.13 0.0 172.33 38.814 K Factor= 27.66 109 49.90 2.157 T 10.0 3.000 34.843 to 120.0 0.0 10.000 -1.299 164 49.9 0.0211 0.0 13.000 0.274 Vel = 4.38 164 0.0 2.157 2T 20.0 135.960 33.818 to 120.0 0.0 20.000 0.0 165 49.9 0.0211 0.0 155.960 3.290 Vel = 4.38 165 0.0 2.157 T 10.0 3.000 37.108 to 120.0 0.0 10.000 1.299 146 49.9 0.0212 0.0 13.000 0.275 Vel = 4.38 0.0 49.90 38.682 K Factor = 8.02 110 45.78 2.157 T 10.0 3.000 34.958 to 120.0 0.0 10.000 -1.299 166 45.78 0.0179 0.0 13.000 0.233 Vel = 4.02 166 0.0 2.157 2T 20.0 136.460 33.892 to 120.0 0.0 20.000 0.0 167 45.78 0.0180 0.0 156.460 2.815 Vel = 4.02 167 0.0 2.157 T 10.0 3.000 36.707 to 120.0 0.0 10.000 1.299 145 45.78 0.0180 0.0 13.000 0.234 Vel = 4.02 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 10 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 45.78 38.240 K Factor = 7.40 111 44.26 2.157 1 10.0 3.000 35.057 to 120.0 0.0 10.000 -1.299 168 44.26 0.0168 0.0 13.000 0.219 Vel = 3.89 168 0.0 2.157 21 20.0 136.460 33.977 to 120.0 0.0 20.000 0.0 169 44.26 0.0169 0.0 156.460 2.645 Vel = 3.89 169 0.0 2.157 T 10.0 3.000 36.622 to 120.0 0.0 10.000 1.299 144 44.26 0.0169 0.0 13.000 0.220 Vel = 3.89 0.0 44.26 38.141 K Factor = 7.17 112 42.92 2.157 T 10.0 3.000 35.143 to 120.0 0.0 10.000 -1.299 170 42.92 0.0159 0.0 13.000 0.207 Vel = 3.77 170 0.0 2.157 2T 20.0 136.460 34.051 to 120.0 0.0 20.000 0.0 171 42.92 0.0160 0.0 156.460 2.498 Vel = 3.77 171 0.0 2.157 T 10.0 3.000 36.549 to 120.0 0.0 10.000 1.299 143 42.92 0.0159 0.0 13.000 0.207 Vel = 3.77 0.0 42.92 38.055 K Factor = 6.96 113 41.74 2.157 T 10.0 3.000 35.216 to 120.0 0.0 10.000 -1.299 172 41.74 0.0152 0.0 13.000 0.197 Vel = 3.66 172 0.0 2.157 21 20.0 136.460 34.114 to 120.0 0.0 20.000 0.0 173 41.74 0.0152 0.0 156.460 2.372 VeI= 3.66 173 0.0 2.157 T 10.0 3.000 36.486 to 120.0 0.0 10.000 1.299 142 41.74 0.0152 0.0 13.000 0.197 Vel = 3.66 0.0 41.74 37.982 K Factor = 6.77 114 40.71 2.157 T 10.0 3.000 35.278 to 120.0 0.0 10.000 -1.299 174 40.71 0.0145 0.0 13.000 0.188 Vel = 3.57 174 0.0 2.157 2T 20.0 136.460 34.167 to 120.0 0.0 20.000 0.0 175 40.71 0.0145 0.0 156.460 2.266 Vel = 3.57 175 0.0 2.157 T 10.0 3.000 36.433 to 120.0 0.0 10.000 1.299 141 40.71 0.0145 0.0 13.000 0.188 Vel = 3.57 0.0 40.71 37.920 K Factor = 6.61 115 39.84 2.157 1 10.0 3.000 35.330 to 120.0 0.0 10.000 -1.299 176 39.84 0.0138 0.0 13.000 0.180 Vel = 3.50 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 11 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .,Co.or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 176 0.0 2.157 2T 20.0 136.460 34.211 to 120.0 0.0 20.000 0.0 177 39.84 0.0139 0.0 156.460 2.177 Vel = 3.50 177 0.0 2.157 T 10.0 3.000 36.388 to 120.0 0.0 10.000 1.299 140 39.84 0.0139 0.0 13.000 0.181 Vel = 3.50 0.0 39.84 37.868 K Factor = 6.47 116 39.04 2.157 T 10.0 3.000 35.377 to 120.0 0.0 10.000 -1.299 178 39.04 0.0134 0.0 13.000 0.174 Vel= 3.43 178 0.0 2.157 21 20.0 136.460 34.252 to 120.0 0.0 20.000 0.0 179 39.04 0.0134 0.0 156.460 2.096 Vel = 3.43 179 0.0 2.157 1 10.0 3.000 36.348 to 120.0 0.0 10.000 1.299 139 39.04 0.0134 0.0 13.000 0.174 Vel = 3.43 0.0 39.04 37.821 K Factor = 6.35 117 38.38 2.157 1 10.0 3.000 35.415 to 120.0 0.0 10.000 -1.299 180 38.38 0.0129 0.0 13.000 0.168 Vel = 3.37 180 0.0 2.157 21 20.0 136.460 34.284 to 120.0 0.0 20.000 0.0 181 38.38 0.0130 0.0 156.460 2.031 Vel = 3.37 181 0.0 2.157 T 10.0 3.000 36.315 to 120.0 0.0 10.000 1.299 138 38.38 0.0130 0.0 13.000 0.169 Vel = 3.37 0.0 38.38 37.783 K Factor = 6.24 118 37.84 2.157 T 10.0 3.000 35.445 to 120.0 0.0 10.000 -1.299 182 37.84 0.0126 0.0 13.000 0.164 Vel = 3.32 182 0.0 2.157 21 20.0 136.460 34.310 to 120.0 0.0 20.000 0.0 183 37.84 0.0126 0.0 156.460 1.979 Vel = 3.32 183 0.0 2.157 T 10.0 3.000 36.289 to 120.0 0.0 10.000 1.299 137 37.84 0.0127 0.0 13.000 0.165 Vel = 3.32 0.0 37.84 37.753 K Factor = 6.16 119 37.43 2.157 1 10.0 3.000 35.468 to 120.0 0.0 10.000 -1.299 184 37.43 0.0124 0.0 13.000 0.161 VeI= 3.29 184 0.0 2.157 2T 20.0 136.460 34.330 to 120.0 0.0 20.000 0.0 185 37.43 0.0124 0.0 156.460 1.940 Vel = 3.29 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 12 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 185 0.0 2.157 T 10.0 3.000 36.270 to 120.0 0.0 10.000 1.299 136 37.43 0.0124 0.0 13.000 0.161 Vel = 3.29 0.0 37.43 37.730 K Factor = 6.09 120 37.13 2.157 T 10.0 3.000 35.485 to 120.0 0.0 10.000 -1.299 186 37.13 0.0122 0.0 13.000 0.159 Vel = 3.26 186 0.0 2.157 2T 20.0 136.460 34.345 to 120.0 0.0 20.000 0.0 187 37.13 0.0122 0.0 156.460 1.910 Vel = 3.26 187 0.0 2.157 1 10.0 3.000 36.255 to 120.0 0.0 10.000 1.299 135 37.13 0.0122 0.0 13.000 0.159 Vel = 3.26 0.0 37.13 37.713 K Factor= 6.05 121 36.91 2.157 T 10.0 3.000 35.497 to 120.0 0.0 10.000 -1.299 188 36.91 0.0121 0.0 13.000 0.157 Vel = 3.24 188 0.0 2.157 2T 20.0 136.460 34.355 to 120.0 0.0 20.000 0.0 189 36.91 0.0121 0.0 156.460 1.890 Vel = 3.24 189 0.0 2.157 1 10.0 3.000 36.245 to 120.0 0.0 10.000 1.299 134 36.91 0.0121 0.0 13.000 0.157 Vel = 3.24 0.0 36.91 37.701 K Factor = 6.01 122 34.84 2.157 T 10.0 3.000 35.712 to 120.0 0.0 10.000 -1.299 190 34.84 0.0108 0.0 13.000 0.141 Vel = 3.06 190 0.0 2.157 2T 20.0 136.460 34.554 to 120.0 0.0 20.000 0.0 191 34.84 0.0109 0.0 156.460 1.698 Vel = 3.06 191 0.0 2.157 T 10.0 3.000 36.252 to 120.0 0.0 10.000 1.299 133 34.84 0.0109 0.0 13.000 0.142 Vel = 3.06 0.0 34.84 37.693 K Factor = 5.67 123 33.59 2.157 T 10.0 3.000 35.836 to 120.0 0.0 10.000 -1.299 192 33.59 0.0102 0.0 13.000 0.132 Vel = 2.95 192 0.0 2.157 2T 20.0 136.460 34.669 to 120.0 0.0 20.000 0.0 193 33.59 0.0101 0.0 156.460 1.588 Vel = 2.95 193 0.0 2.157 T 10.0 3.000 36.257 to 120.0 0.0 10.000 1.299 132 33.59 0.0102 0.0 13.000 0.132 Vel = 2.95 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 13 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 33.59 37.688 K Factor = 5.47 124 33.55 2.157 T 10.0 3.000 35.839 to 120.0 0.0 10.000 -1.299 194 33.55 0.0101 0.0 13.000 0.131 Vel = 2.95 194 0.0 2.157 2T 20.0 136.460 34.671 to 120.0 0.0 20.000 0.0 195 33.55 0.0101 0.0 156.460 1.584 Vel = 2.95 195 0.0 2.157 T 10.0 3.000 36.255 to 120.0 0.0 10.000 1.299 131 33.55 0.0102 0.0 13.000 0.132 Vel = 2.95 0.0 33.55 37.686 K Factor = 5.47 125 33.54 2.157 T 10.0 3.000 35.839 to 120.0 0.0 10.000 -1.299 196 33.54 0.0101 0.0 13.000 0.131 Vel = 2.94 196 0.0 2.157 2T 20.0 136.460 34.671 to 120.0 0.0 20.000 0.0 197 33.54 0.0101 0.0 156.460 1.583 Vel = 2.94 197 0.0 2.157 T 10.0 3.000 36.254 to 120.0 0.0 10.000 1.299 130 33.54 0.0102 0.0 13.000 0.132 Vel = 2.94 0.0 33.54 37.685 K Factor = 5.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PTI-I.I.M Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 19572 - Atec - Design TI & HilePile_FP design Building : FP6 Location : CAM INO VIDA ROBLE System : Area 2 Contract : 19572 Data File : 20060 - Alphatec Spine - Fp Design-clean) AREA 2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 19572 - Atec - Design TI & HilePile_FP design Date HYDRAULIC CALCULATIONS for Project name: AlEC Location: CAMINO VIDA ROBLE Drawing no: FP6 Date: 3-23-20 Design Remote area number: Area 2 Remote area location: SERVER Occupancy classification: ORDINARY HAZARD II Density: - Gpm/SqFt Area of application: 269 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: VK302 K5.6 Q. R. No. of sprinklers calculated: 4 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 330.17 -GPM @ 42.9 -Psi Type of system: WET Volume of dry orpreaction system: N/A - Gal Water supply information Date: 3-19-20 Location: SEE PLAN Source: CITY OF CARLSBAD Name of contractor: TITAN FIRE PROTECTION Address: 2880 SCOTT ST. Phone number: 760-295-3436 Name of designer: M. Marron Authority having jurisdiction: CITY OF SAN DIEGO Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 19572 - Atec - Design TI & HilePile_FP design Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 3.898 C2 - Residual Pressure: 95.8 D2 - System Flow : 80.172 C2 - Residual Flow : 6550 D2 - System Pressure : 42.908 Hose ( Demand) : 250 D3 - System Demand : 330.172 Safety Margin : 75.800 150 140 130 Cl P 120 : ___ R 110 - C2 E 100 5.90 580 U70 R6° E5° D2 D 40 3 0 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N l 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 3 19572 - Atec - Design TI & HilePile_FP design Date Fitting Legend Abbrev. Name % ~ 1 1% 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA I39O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zit Wilkins 950DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivolont lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 19572 - Atec - Design TI & HilePile_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 44 9.0 5.6 12.13 na 19.5 0.15 130 7.0 46 10.0 14.53 na 5 10.0 16.02 na 4 10.0 16.35 na PV 10.0 20.79 na 7 24.0 24.6 na 8 24.0 24.6 na 6 24.0 24.6 na 9 24.0 24.6 na 10 24.0 24.6 na 11 24.0 24.6 na 12 24.0 24.6 na 13 24.0 24.6 na 14 24.0 24.61 na 15 24.0 24.61 na 16 24.0 24.61 na 17 24.0 24.61 na 18 24.0 24.61 na 19 24.0 24.61 na 20 24.0 24.61 na 21 24.0 24.61 na 22 24.0 24.61 na 23 24.0 24.61 na 24 24.0 24.61 na 25 27.0 23.31 na 26 27.0 23.33 na 27 24.0 24.63 na 28 24.0 24.63 na 29 24.0 24.63 na 30 24.0 24.63 na 31 24.0 24.63 na 32 24.0 24.63 na 33 24.0 24.63 na 34 24.0 24.64 na 35 24.0 24.64 na 36 24.0 24.64 na 37 24.0 24.64 na 38 24.0 24.64 na 39 24.0 24.64 na 40 24.0 24.64 na 41 24.0 24.64 na 42 24.0 24.64 na 43 24.0 24.64 na TR2 24.0 24.97 na BR2 0.5 35.15 na BF1 -3.0 36.67 na BF2 -3.0 44.19 na UGI -3.0 44.2 na TEST 0.0 42.91 na 250.0 1 9.0 5.6 12.27 na 19.62 0.15 130 7.0 3 10.5 14.49 na 47 9.0 5.6 13.52 na 20.59 0.15 130 7.0 49 9.0 5.6 13.36 na 20.47 0.15 130 7.0 51 24.0 24.6 na 52 24.0 24.6 na 53 24.0 24.6 na 54 27.0 23.3 na 55 27.0 23.34 na 56 24.0 24.64 na 57 24.0 24.64 na 58 24.0 24.64 na 59 24.0 24.64 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard TITAN FIRE PROTECTION, INC. Page 5 19572 - Atec - Design TI & HilePile_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 24.0 24.64 na 27.0 23.3 na 27.0 23.34 na 27.0 23.3 na 27.0 23.34 na 27.0 23.3 na 27.0 23.34 na 27.0 23.3 na 27.0 23.34 na 27.0 23.3 na 27.0 23.34 na 27.0 23.31 na 27.0 23.34 na 27.0 23.31 na 27.0 23.34 na 27.0 23.31 na 27.0 23.34 na 27.0 23.31 na 27.0 23.34 na 27.0 23.31 na 27.0 23.34 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na 27.0 23.31 na 27.0 23.33 na The maximum velocity is 11.58 and it occurs in the pipe between nodes 4 and PV Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 19572 - Atec - Design TI & HitePite_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 44 19.50 1.049 3E 4.282 12.000 12.125 K Factor= 5.60 to 100.0 0.0 4.282 -0.433 46 19.5 0.1740 0.0 16.282 2.833 Vet = 7.24 46 20.47 1.38 T 4.282 4.375 14.525 to 100.0 0.0 4.282 0.0 5 39.97 0.1726 0.0 8.657 1.494 Vet = 8.57 5 0.0 1.682 0.0 5.000 16.019 to 100.0 0.0 0.0 0.0 4 39.97 0.0660 0.0 5.000 0.330 Vet = 5.77 4 40.20 1.682 E 2.855 13.625 16.349 to 100.0 Eqt 2.141 4.996 0.0 PV 80.17 0.2387 0.0 18.621 4.444 VeI = 11.58 PV 0.0 1.682 3E 8.564 27.080 20.793 to 100.0 T 5.71 14.274 -6.063 6 80.17 0.2387 0.0 41.354 9.870 Vet = 11.58 0.0 80.17 24.600 KFactor= 16.16 7 -4.38 6.357 0.0 10.000 24.600 to 120.0 0.0 0.0 0.0 8 -4.38 0.0 0.0 10.000 0.0 Vet = 0.04 8 -4.38 6.357 0.0 4.950 24.600 to 120.0 0.0 0.0 0.0 6 -8.76 0.0 0.0 4.950 0.0 Vet = 0.09 6 67.07 6.357 0.0 5.250 24.600 to 120.0 0.0 0.0 0.0 9 58.31 0.0 0.0 5.250 0.0 Vet = 0.59 9 -4.27 6.357 0.0 10.000 24.600 to 120.0 0.0 0.0 0.0 10 54.04 0.0002 0.0 10.000 0.002 Vet = 0.55 10 -4.12 6.357 0.0 10.000 24.602 to 120.0 0.0 0.0 0.0 11 49.92 0.0001 0.0 10.000 0.001 Vet = 0.50 11 -4.00 6.357 0.0 10.000 24.603 to 120.0 0.0 0.0 0.0 12 45.92 0.0001 0.0 10.000 0.001 Vet = 0.46 12 -3.89 6.357 0.0 10.000 24.604 to 120.0 0.0 0.0 0.0 13 42.03 0.0 0.0 10.000 0.0 Vel = 0.42 13 -3.78 6.357 0.0 10.000 24.604 to 120.0 0.0 0.0 0.0 14 38.25 0.0001 0.0 10.000 0.001 Vet = 0.39 14 -3.70 6.357 0.0 11.000 24.605 to 120.0 0.0 0.0 0.0 15 34.55 0.0001 0.0 11.000 0.001 VeI = 0.35 15 -3.63 6.357 0.0 11.000 24.606 to 120.0 0.0 0.0 0.0 16 30.92 0.0 0.0 11.000 0.0 Vet = 0.31 16 -3.56 6.357 0.0 11.000 24.606 to 120.0 0.0 0.0 0.0 17 27.36 0.0001 0.0 11.000 0.001 Vet = 0.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 17 -3.50 6.357 0.0 11.000 24.607 to 120.0 0.0 0.0 0.0 18 23.86 0.0 0.0 11.000 0.0 Vel = 0.24 18 -3.47 6.357 0.0 11.000 24.607 to 120.0 0.0 0.0 0.0 19 20.39 0.0 0.0 11.000 0.0 Vel = 0.21 19 -3.43 6.357 0.0 11.000 24.607 to 120.0 0.0 0.0 0.0 20 16.96 0.0 0.0 11.000 0.0 Vel = 0.17 20 -3.41 6.357 0.0 12.000 24.607 to 120.0 0.0 0.0 0.0 21 13.55 0.0001 0.0 12.000 0.001 Vel = 0.14 21 -3.40 6.357 0.0 12.000 24.608 to 120.0 0.0 0.0 0.0 22 10.15 0.0 0.0 12.000 0.0 Vel = 0.10 22 -3.39 6.357 0.0 12.000 24.608 to 120.0 0.0 0.0 0.0 23 6.76 0.0 0.0 12.000 0.0 Vel = 0.07 23 -3.38 6.357 0.0 12.000 24.608 to 120.0 0.0 0.0 0.0 24 3.38 0.0 0.0 12.000 0.0 Vel = 0.03 24 0.0 2.157 1 10.0 3.000 24.608 to 120.0 0.0 10.000 -1.299 25 3.38 0.0001 0.0 13.000 0.001 Vel = 0.30 25 0.0 2.157 2T 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 26 3.38 0.0001 0.0 157.140 0.023 Vel = 0.30 26 0.0 2.157 T 10.0 3.000 23.333 to 120.0 0.0 10.000 1.299 27 3.38 0.0002 0.0 13.000 0.002 Vel = 0.30 27 0.0 6.357 0.0 12.000 24.634 to 120.0 0.0 0.0 0.0 28 3.38 0.0 0.0 12.000 0.0 Vel = 0.03 28 3.38 6.357 0.0 12.000 24.634 to 120.0 0.0 0.0 0.0 29 6.76 0.0 0.0 12.000 0.0 Vel = 0.07 29 3.39 6.357 0.0 12.000 24.634 to 120.0 0.0 0.0 0.0 30 10.15 0.0 0.0 12.000 0.0 Vel = 0.10 30 3.40 6.357 0.0 12.000 24.634 to 120.0 0.0 0.0 0.0 31 13.55 0.0 0.0 12.000 0.0 Vel = 0.14 31 3.41 6.357 0.0 11.000 24.634 to 120.0 0.0 0.0 0.0 32 16.96 0.0001 0.0 11.000 0.001 Vel = 0.17 32 3.43 6.357 0.0 11.000 24.635 to 120.0 0.0 0.0 0.0 33 20.39 0.0 0.0 11.000 0.0 Vel = 0.21 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 33 3.47 6.357 0.0 11.000 24.635 to 120.0 0.0 0.0 0.0 34 23.86 0.0 0.0 11.000 0.0 Vel = 0.24 34 3.50 6.357 0.0 11.000 24.635 to 120.0 0.0 0.0 0.0 35 27.36 0.0001 0.0 11.000 0.001 Vel = 0.28 35 3.56 6.357 0.0 11.000 24.636 to 120.0 0.0 0.0 0.0 36 30.92 0.0 0.0 11.000 0.0 Vel = 0.31 36 3.63 6.357 0.0 11.000 24.636 to 120.0 0.0 0.0 0.0 37 34.55 0.0001 0.0 11.000 0.001 Vel = 0.35 37 3.70 6.357 0.0 10.000 24.637 to 120.0 0.0 0.0 0.0 38 38.25 0.0 0.0 10.000 0.0 Vel = 0.39 38 3.78 6.357 0.0 10.000 24.637 to 120.0 0.0 0.0 0.0 39 42.03 0.0001 0.0 10.000 0.001 Vel = 0.42 39 3.89 6.357 0.0 10.000 24.638 to 120.0 0.0 0.0 0.0 40 45.92 0.0001 0.0 10.000 0.001 Vel = 0.46 40 4.00 6.357 0.0 10.000 24.639 to 120.0 0.0 0.0 0.0 41 49.92 0.0001 0.0 10.000 0.001 Vel = 0.50 41 4.12 6.357 0.0 10.000 24.640 to 120.0 0.0 0.0 0.0 42 54.04 0.0001 0.0 10.000 0.001 Vel = 0.55 42 4.27 6.357 0.0 9.110 24.641 to 120.0 0.0 0.0 0.0 43 58.31 0.0002 0.0 9.110 0.002 Vel = 0.59 43 21.86 4.26 1 20.0 158.070 24.643 to 120.0 0.0 20.000 0.0 TR2 80.17 0.0018 0.0 178.070 0.328 Vel = 1.80 TR2 0.0 8.249 B 18.133 24.500 24.971 to 150.0 0.0 18.133 10.178 BR2 80.17 0.0 0.0 42.633 0.002 Vel = 0.48 BR2 0.0 7.68 E 27.199 82.540 35.151 to 150.0 0.0 27.199 1.516 BFI 80.17 0.0001 0.0 109.739 0.007 Vel = 0.56 BFI 0.0 8.27 4E 95.76 12.000 36.674 to 140.0 Zit 0.0 95.760 7.509 * * Fixed Loss = 7.509 BF2 80.17 0.0001 0.0 107.760 0.007 Vel = 0.48 BF2 0.0 7.68 1 52.887 44.040 44.190 to 150.0 0.0 52.887 0.0 UG1 80.17 0.0001 0.0 96.927 0.006 Vel = 0.56 UG1 0.0 9.42 F 16.622 273.420 44.196 to 150.0 2T 151.107 175.284 -1.299 TEST 80.17 0.0 G 7.555 448.704 0.011 Vel = 0.37 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 9 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 250.00 Qa = 250.00 330.17 42.908 K Factor= 50.40 1 19.62 1.049 3E 4.282 12.000 12.272 K Factor =5.60 to 100.0 0.0 4.282 -0.650 3 19.62 0.1760 0.0 16.282 2.866 Vel = 7.28 3 20.59 1.38 1 4.282 5.140 14.488 to 100.0 0.0 4.282 0.217 4 40.21 0.1745 0.0 9.422 1.644 Vel = 8.63 0.0 40.21 16.349 K Factor = 9.94 47 20.59 1.049 2E 2.855 2.000 13.517 K Factor = 5.60 to 100.0 T 3.568 6.423 -0.650 3 20.59 0.1924 0.0 8.423 1.621 Vel = 7.64 0.0 20.59 14.488 K Factor = 5.41 49 20.47 1.049 2E 2.855 2.000 13.356 K Factor = 5.60 to 100.0 T 3.568 6.423 -0.433 46 20.47 0.1902 0.0 8.423 1.602 Vel = 7.60 0.0 20.47 14.525 K Factor = 5.37 6 13.10 6.357 0.0 7.660 24.600 to 120.0 0.0 0.0 0.0 51 13.1 0.0 0.0 7.660 0.0 Vel = 0.13 51 -4.37 6.357 0.0 10.000 24.600 to 120.0 0.0 0.0 0.0 52 8.73 0.0 0.0 10.000 0.0 Vel = 0.09 52 -4.37 6.357 0.0 10.000 24.600 to 120.0 0.0 0.0 0.0 53 4.36 0.0 0.0 10.000 0.0 Vel = 0.04 53 0.0 2.157 T 10.0 3.000 24.600 to 120.0 0.0 10.000 -1.299 54 4.36 0.0002 0.0 13.000 0.003 Vel = 0.38 54 0.0 2.157 2T 20.0 137.140 23.304 to 120.0 0.0 20.000 0.0 55 4.36 0.0002 0.0 157.140 0.036 Vel = 0.38 55 0.0 2.157 T 10.0 3.000 23.340 to 120.0 0.0 10.000 1.299 56 4.36 0.0002 0.0 13.000 0.003 Vel = 0.38 56 0.0 6.357 0.0 10.000 24.642 to 120.0 0.0 0.0 0.0 57 4.36 0.0 0.0 10.000 0.0 Vel = 0.04 57 4.37 6.357 0.0 10.000 24.642 to 120.0 0.0 0.0 0.0 58 8.73 0.0 0.0 10.000 0.0 Vel = 0.09 58 4.37 6.357 0.0 10.000 24.642 to 120.0 0.0 0.0 0.0 59 13.1 0.0 0.0 10.000 0.0 Vel = 0.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 10 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 59 4.37 6.357 0.0 10.000 24.642 to 120.0 0.0 0.0 0.0 60 17.47 0.0001 0.0 10.000 0.001 Vel = 0.18 60 4.39 6.357 0.0 0.890 24.643 to 120.0 0.0 0.0 0.0 43 21.86 0.0 0.0 0.890 0.0 Vel = 0.22 0.0 21.86 24.643 K Factor= 4.40 52 4.36 2.157 T 10.0 3.000 24.600 to 120.0 0.0 10.000 -1.299 61 4.36 0.0002 0.0 13.000 0.003 Vel = 0.38 61 0.0 2.157 2T 20.0 137.140 23.304 to 120.0 0.0 20.000 0.0 62 4.36 0.0002 0.0 157.140 0.036 Vel = 0.38 62 0.0 2.157 1 10.0 3.000 23.340 to 120.0 0.0 10.000 1.299 57 4.36 0.0002 0.0 13.000 0.003 Vel = 0.38 0.0 4.36 24.642 K Factor = 0.88 51 4.37 2.157 T 10.0 3.000 24.600 to 120.0 0.0 10.000 -1.299 63 4.37 0.0002 0.0 13.000 0.003 Vel = 0.38 63 0.0 2.157 21 20.0 137.140 23.304 to 120.0 0.0 20.000 0.0 64 4.37 0.0002 0.0 157.140 0.036 Vel = 0.38 64 0.0 2.157 1 10.0 3.000 23.340 to 120.0 0.0 10.000 1.299 58 4.37 0.0002 0.0 13.000 0.003 Vel = 0.38 0.0 4.37 24.642 K Factor= 0.88 7 4.38 2.157 T 10.0 3.000 24.600 to 120.0 0.0 10.000 -1.299 65 4.38 0.0002 0.0 13.000 0.003 Vel = 0.38 65 0.0 2.157 2T 20.0 137.140 23.304 to 120.0 0.0 20.000 0.0 66 4.38 0.0002 0.0 157.140 0.036 Vel = 0.38 66 0.0 2.157 T 10.0 3.000 23.340 to 120.0 0.0 10.000 1.299 59 4.38 0.0002 0.0 13.000 0.003 Vel = 0.38 0.0 4.38 24.642 K Factor= 0.88 8 4.39 2.157 1 10.0 3.000 24.600 to 120.0 0.0 10.000 -1.299 67 4.39 0.0002 0.0 13.000 0.003 Vel = 0.39 67 0.0 2.157 21 20.0 137.140 23.304 to 120.0 0.0 20.000 0.0 68 4.39 0.0002 0.0 157.140 0.036 Vel = 0.39 68 0.0 2.157 1 10.0 3.000 23.340 to 120.0 0.0 10.000 1.299 60 4.39 0.0003 0.0 13.000 0.004 Vel = 0.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 11 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 4.39 24.643 K Factor= 0.88 9 4.27 2.157 1 10.0 3.000 24.600 to 120.0 0.0 10.000 -1.299 69 4.27 0.0002 0.0 13.000 0.003 Vel = 0.37 69 0.0 2.157 21 20.0 137.140 23.304 to 120.0 0.0 20.000 0.0 70 4.27 0.0002 0.0 157.140 0.035 Vel = 0.37 70 0.0 2.157 1 10.0 3.000 23.339 to 120.0 0.0 10.000 1.299 42 4.27 0.0002 0.0 13.000 0.003 Vel = 0.37 0.0 4.27 24.641 K Factor = 0.86 10 4.13 2.157 T 10.0 3.000 24.602 to 120.0 0.0 10.000 -1.299 71 4.13 0.0002 0.0 13.000 0.002 Vel = 0.36 71 0.0 2.157 2T 20.0 137.140 23.305 to 120.0 0.0 20.000 0.0 72 4.13 0.0002 0.0 157.140 0.033 Vel = 0.36 72 0.0 2.157 T 10.0 3.000 23.338 to 120.0 0.0 10.000 1.299 41 4.13 0.0002 0.0 13.000 0.003 Vel = 0.36 0.0 4.13 24.640 K Factor = 0.83 11 4.00 2.157 T 10.0 3.000 24.603 to 120.0 0.0 10.000 -1.299 73 4.0 0.0002 0.0 13.000 0.002 Vel = 0.35 73 0.0 2.157 2T 20.0 137.140 23.306 to 120.0 0.0 20.000 0.0 74 4.0 0.0002 0.0 157.140 0.031 Vel = 0.35 74 0.0 2.157 1 10.0 3.000 23.337 to 120.0 0.0 10.000 1.299 40 4.0 0.0002 0.0 13.000 0.003 Vel = 0.35 0.0 4.00 24.639 K Factor= 0.81 12 3.88 2.157 T 10.0 3.000 24.604 to 120.0 0.0 10.000 -1.299 75 3.88 0.0002 0.0 13.000 0.002 Vel = 0.34 75 0.0 2.157 21 20.0 137.140 23.307 to 120.0 0.0 20.000 0.0 76 3.88 0.0002 0.0 157.140 0.029 Vel = 0.34 76 0.0 2.157 T 10.0 3.000 23.336 to 120.0 0.0 10.000 1.299 39 3.88 0.0002 0.0 13.000 0.003 Vel = 0.34 0.0 3.88 24.638 K Factor = 0.78 13 3.79 2.157 1 10.0 3.000 24.604 to 120.0 0.0 10.000 -1.299 77 3.79 0.0002 0.0 13.000 0.003 Vel = 0.33 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 12 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 77 0.0 2.157 2T 20.0 137.140 23.308 to 120.0 0.0 20.000 0.0 78 3.79 0.0002 0.0 157.140 0.028 Vel = 0.33 78 0.0 2.157 T 10.0 3.000 23.336 to 120.0 0.0 10.000 1.299 38 3.79 0.0002 0.0 13.000 0.002 Vel = 0.33 0.0 3.79 24.637 K Factor = 0.76 14 3.70 2.157 T 10.0 3.000 24.605 to 120.0 0.0 10.000 -1.299 79 3.7 0.0002 0.0 13.000 0.002 Vel = 0.32 79 0.0 2.157 21 20.0 137.140 23.308 to 120.0 0.0 20.000 0.0 80 3.7 0.0002 0.0 157.140 0.027 Vel = 0.32 80 0.0 2.157 T 10.0 3.000 23.335 to 120.0 0.0 10.000 1.299 37 3.7 0.0002 0.0 13.000 0.003 Vel = 0.32 0.0 3.70 24.637 K Factor = 0.75 15 3.62 2.157 T 10.0 3.000 24.606 to 120.0 0.0 10.000 -1.299 81 3.62 0.0002 0.0 13.000 0.002 Vel = 0.32 81 0.0 2.157 2T 20.0 137.140 23.309 to 120.0 0.0 20.000 0.0 82 3.62 0.0002 0.0 157.140 0.026 Vel = 0.32 82 0.0 2.157 T 10.0 3.000 23.335 to 120.0 0.0 10.000 1.299 36 3.62 0.0002 0.0 13.000 0.002 Vel = 0.32 0.0 3.62 24.636 K Factor = 0.73 16 3.56 2.157 T 10.0 3.000 24.606 to 120.0 0.0 10.000 -1.299 83 3.56 0.0002 0.0 13.000 0.002 Vel = 0.31 83 0.0 2.157 2T 20.0 137.140 23.309 to 120.0 0.0 20.000 0.0 84 3.56 0.0002 0.0 157.140 0.025 Vel = 0.31 84 0.0 2.157 T 10.0 3.000 23.334 to 120.0 0.0 10.000 1.299 35 3.56 0.0002 0.0 13.000 0.003 Vel = 0.31 0.0 3.56 24.636 K Factor = 0.72 17 3.51 2.157 T 10.0 3.000 24.607 to 120.0 0.0 10.000 -1.299 85 3.51 0.0001 0.0 13.000 0.001 Vel = 0.31 85 0.0 2.157 2T 20.0 137.140 23.309 to 120.0 0.0 20.000 0.0 86 3.51 0.0002 0.0 157.140 0.025 Vel = 0.31 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 13 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 86 0.0 2.157 T 10.0 3.000 23.334 to 120.0 0.0 10.000 1.299 34 3.51 0.0002 0.0 13.000 0.002 Vel = 0.31 0.0 3.51 24.635 K Factor = 0.71 18 3.47 2.157 T 10.0 3.000 24.607 to 120.0 0.0 10.000 -1.299 87 3.47 0.0002 0.0 13.000 0.002 Vel = 0.30 87 0.0 2.157 2T 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 88 3.47 0.0002 0.0 157.140 0.024 Vel = 0.30 88 0.0 2.157 T 10.0 3.000 23.334 to 120.0 0.0 10.000 1.299 33 3.47 0.0002 0.0 13.000 0.002 Vel = 0.30 0.0 3.47 24.635 K Factor = 0.70 19 3.43 2.157 1 10.0 3.000 24.607 to 120.0 0.0 10.000 -1.299 89 3.43 0.0002 0.0 13.000 0.002 Vel = 0.30 89 0.0 2.157 2T 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 90 3.43 0.0001 0.0 157.140 0.023 Vel = 0.30 90 0.0 2.157 1 10.0 3.000 23.333 to 120.0 0.0 10.000 1.299 32 3.43 0.0002 0.0 13.000 0.003 Vel = 0.30 0.0 3.43 24.635 K Factor = 0.69 20 3.41 2.157 T 10.0 3.000 24.607 to 120.0 0.0 10.000 -1.299 91 3.41 0.0002 0.0 13.000 0.002 Vel = 0.30 91 0.0 2.157 2T 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 92 3.41 0.0001 0.0 157.140 0.023 Vel = 0.30 92 0.0 2.157 T 10.0 3.000 23.333 to 120.0 0.0 10.000 1.299 31 3.41 0.0002 0.0 13.000 0.002 Vel = 0.30 0.0 3.41 24.634 K Factor = 0.69 21 3.40 2.157 T 10.0 3.000 24.608 to 120.0 0.0 10.000 -1.299 93 3.4 0.0001 0.0 13.000 0.001 Vel = 0.30 93 0.0 2.157 21 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 94 3.4 0.0001 0.0 157.140 0.023 Vel = 0.30 94 0.0 2.157 T 10.0 3.000 23.333 to 120.0 0.0 10.000 1.299 30 3.4 0.0002 0.0 13.000 0.002 Vel = 0.30 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 14 19572 - Atec - Design TI & HilePile_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C', or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3.40 24.634 K Factor= 0.69 22 3.39 2.157 T 10.0 3.000 24.608 to 120.0 0.0 10.000 -1.299 95 3.39 0.0001 0.0 13.000 0.001 Vel = 0.30 95 0.0 2.157 21 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 96 3.39 0.0001 0.0 157.140 0.023 Vel = 0.30 96 0.0 2.157 1 10.0 3.000 23.333 to 120.0 0.0 10.000 1.299 29 3.39 0.0002 0.0 13.000 0.002 Vel = 0.30 0.0 3.39 24.634 K Factor = 0.68 23 3.38 2.157 1 10.0 3.000 24.608 to 120.0 0.0 10.000 -1.299 97 3.38 0.0001 0.0 13.000 0.001 Vel = 0.30 97 0.0 2.157 2T 20.0 137.140 23.310 to 120.0 0.0 20.000 0.0 98 3.38 0.0001 0.0 157.140 0.023 Vel = 0.30 98 0.0 2.157 T 10.0 3.000 23.333 to 120.0 0.0 10.000 1.299 28 3.38 0.0002 0.0 13.000 0.002 Vel = 0.30 0.0 3.38 24.634 K Factor= 0.68 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 OMB 0103-0061 Exp. 31 Mar 2017 DEPARTMENT OF THE NAVY LOCAL POPULATION ID CARD/BASE ACCESS PASS REGISTRATION PRIVACY ACT STATEMENT: AUTHORITY: IC) U.S.C. 5013, Secretary of the Navy; 10 U.S.C.5041, Headquarters, Marine Caps; OPNAVINST 5530. 14E, Navy Phya4cat Secnty Marine Corp Order 5530.14A, Manne CorpPhy!icat Security Program Manual; and EQ. 0397 (SSN), as amended, SORN NO5512.2. PURPOSE(S); lócontrel physical access tn Depadenenl of Deanze(DoO), Qepamnentot the Navy (DON) or U.S. Manna Cori In kxiaitJots controlled ormahen, Wrda1tao,s, facttee or areas over wtidDoO, DON, or U.S Manna Carpe ha recpoeciotIpeby 4ent*n rjiitian to4iva) through te ueofbiometñc databases and associated data procaaeiigWormaltoo 5ervicec for designated poplations for pw ecotprofocing U. S 1cooldionlaw 9mmmeriftationat arm of reeponandty, arid mationto aaue badges, replace Iota badges, and retrieve paaee opon sappration;to maintain vkitor etatte collect it*rrnaonto adi46cate access to laci)ty; and track the entry%exil times of peraoenet. ROUTINE USE(S): To designated centradora. Federal agencies, andforeqn g veavnent for the prrpean at graehrvj Navy off ciab access to their facility, DISCLOSURE. Providing registration information is voturitary, Failure to provide requested ntonnation may result in denial of acce6a to benefits, pnndegea and I)ol) wetaltahans ,ic,tea and b**nge. IDENTITY PROOFING AND APPLICANT INFORMATION I. LAST NAME: 2. 1IRST NAME: 3, MIDDLE NAME: 4. NAME SUFFIX: LII Jr LI Sr LI I LI ti E] III L] IV 5 HISPAMCOR E] YES LU 6. RACE E rW A4AMERICAN 11AS1AN 11CRGNER PACIFIC U] U]0RC)t.AC) U E] AMERICAN LATINO Checkoee) -J (Che,c*orioo,rnoro): L.J ISIL ANDER 7 GENDER LI MALE []FEMALE B DATE OF BIRTH 9 CITY OF BIRTH 10 STATE OF BIRTH 11 BIRTH COUNTRY 12, US CITIZEN (cheek): LI YES LI NO 13. DUAL CITIZENSHIP- E]YESE]NO I CITIZENSHIP IF OTHER THAN US (Cotmity): U.S. Citizen Minimum Documentation Required: By Birth Sociat Security No andlar State ID/Drivers License. Naturalized Certification Number Petition Number, Date, Place and Court, United Slates passport number, Social Security No and/or State ID/Drivers License. Derived - Parent's certification number, Social Security No and/or State ID/Drivers License. Allen Minimum Documentation Required: Re9istration Number, Expiration date, Date of entry, Port of entry. 14. IDENTITY SOURCE DOCUMENTS PRESENTED: 15. DOCUMENT NUMBER. 16. ISSUED STATE/COURT: 17, ISSUED BY COUNTRY: ' 18. ISSUED: 19 EXPIRES: £1 Social Security No. United States E State ID1Drivars License United States E Passport No. D Cerli&alion Number and Petition Number D Derived - Parent's Certification Number United States O Ahen Registration No. United States Date of EnW Prt at Entry: OTHER APPROVED IDENTITY SOURCE DOCUMENTS: 26, WEIGHT 21, HEIGHT 22, HAIR COLOR (Cheek one): 23, EYE COLOR (Check one) Powide): (inches): } Blond []Brown Black Gray Red Brown [j] Green LI Blue LI Hazel I [j] White El Silver LII Auburn [] Eakl Black Gray Violet Unknown 24. HOME AI5DRESS (11?cagte cI4 store, zp code): !'IOME PP-I)N (include Area Code): 20203 Elfin Forest Rd, Escondido, CA, 92029 760-520-4309 2, UASE SPONSOF?S NAME: SPONSOR PHONE (Thcaide Area code): U. Robert A. Winter NAVFAC CM 559-314-4601 EMPLOYMENT ACTIVITY INFCRMATON EMPLOYER NAME AND ADDRESS ( decay/maze" ecx EMPLOYER PHONE (Tholude Area Code): Soltek. Pacific Construction, 7,424 Congress Street, San Diego, CA.. 92110 61.9-296-6247 SUPERVISOR NAME AND ADDRESS (-MM ciiae/z code): SUPERVISOR PI{ONE (tneMte Area Code): Ronald Hicks, 1080 Holland Ave. Clovis, CA. 93612 559-294-7101 SECNAV 551211 (APR 2014) FOR OFFICIAL USE ONLY WHEN FILLED- PRIVACY SENSITIVE: Page 1 of 3 Any misuse or unauthorized ctisciostwe of this information may result in both criminat and civil penalties. OMB 0703-00I Exp. 31 Mar 2017 Check the applicable box for WORK HOURS box, or cheek the OTHER box and enter the work hours then cheek the applicable for WORK DAYS: WORK HOURS: LIJ 0600-1800 []0000-1700 F] OTHER WORK DAYS: [IaN [I M []T [I] W E] TH [:] F PRIOR FELONY CONVICTIONS Have you ever been convicted eta Felony? []ves []No -ffillat REQUIREMENT TO RETURN LOCAL POPULATION II) CARD I understand that I am required to return my Local Population Identification Card to the Base Pass Office when it expires or if my employment is terminated for any reason. _______ (iwtufi AUTHORIZATION AND RELEASE AND CERTIFICATION 31 I hereby authorize the DOD/DON and other authorized Federal agendas to obtain any information required from the Federal government and/or state agencies, including but not limited to, the Federal Bureau of Investigation (FBI), the Defense Security Service (058), the US. Department of Homeland Security (OHS). I have been notified of DON right to perform minimal vetting and fitness determination as a condition of access to DON iristaation/facilthes. I understand that I may request a record identifier, the source of the record and that I may obtain records from the State Low Enforcement Office as may be available to me under the law. I also understand that this information With be treated as privileged and confidential iriforrnation. I release any individual, indudirig records custodians, any component at the US. Government or the individual State Criminal History Repository supplying information, from all liability for damages that may result an account of compliance, or any attempts to cemply with this authorization. This release is binding, now and in the future, on my heirs assigns, associates and personal representative(s) of any nature Copies of this authorization that show ray signature are as valid as the or'nal release signed by me. FALSE STATEMENTS ARE PUNISHABLE BY LAW AND COULD RESULT IN FINES AND/OR IMPRISONMENT UP TO FIVE YEARS, BEFORE SIGNING THIS FORM, REVIEW IT CAREFULLY TO MAKE SURE YOU HAVE ANSWERED ALL QUESTIONS FULLY AND CORRECTLY. I DECLARE UNDER PENALTY OF PERJURY THAT THE STATEMENTS MADE BY ME ON THIS FORM ARE TRUE, COMPLETE AND CORRECT DATE SIGNATURE_______________________________ FINAL DETERMINATION ON YOUR ACCESS: The Base Commanding Officer has final authority for determination on granting physical access to DON controlled Instaflations/facitities under hi/her jurisdiction. BELOW COMPLETED BY BASE REGISTRAR PERSON CONDUCTING IDENTY PROOFING and NCIC CHECK 32. INFORMATION VERIFIED BY: 33. ENTERED IN C/S SYSTEM BY: 34. PASS ISSUE DATE: 35. PASS EXPIRATION DATE: 36, NCIC CHECK PERFORMED BY: 37. RESULTS OF NCIC CHECK: 38. RESULTS OF LOCAL RECORDS CHECK: []NO RECORDS []RECORD IDENTIFIER [INo RECORDS []RECORD IDENTIFIER RECORD NUMBER: RECORD NUMBER: Office of Under Secretary of Defense Directive-Type Memorandum (DTM} 0f0121 Ninterim Policy Guidance for Dot) Physical Access Control," December 8, 2009 DTM 00-012 requires that DoD Installation government representatives query the National Crime Information Center (NCIC) and Terrorist Screening Database to vet the claimed identity arid to determine the fitness of non-federal government and nori4)c04ssued card holders (ie. visitors) who are requesting unescorted access to 8 DoD installation. The minimum criteria tedetecrnine the fitness of a visitor is: t) not on a terrorist watch list 2) not on an DoD installation debarment list, and 3) not on a FBI National Criminal Information Canter (NCtC) felony wants and warrants list Additionally, SECNAV Memo, Policy for Sex Offender Tracking and Assignment and Access Restrictions within the Department of the Navy, of 7 Oct 08 and OPNAVINST 17523 established the Navyis policy on sex offenders, requiring Region Commanders (REOCOMS) and Installation Commanding Officers (COs) to prohibit sex offender access to DeN facilities and Navy owned, leased or PPV housing. This farm describes the authority and purpose to collect and share the required information; and identifies the applicant/visitor and sponsor; and authorizes the Dot) to perform the minimum vetting and fitness determination criteria. A favorable response on the vetting and fitness determination is required to receive access to DOD controlled instaliation/facihties., SLCNAV 551211 (APR 21114) FOR OFFICIAL USE ONLY WHEN FILLED. PRIVACY SENSITIVE: Page 2 @13 Any misuse or unauthorized disclosure at tins information may resrift:in both criminal and civil penalties. OMB 07030061 Exp1 Mar 2017 Instruction for completing the Local Population Access Registration Form IMSTRUCTICe: Please complete at information in black WtK (printed) or by typing. By votantarlty providing your Personal in!orrnatton, you agree to the tollowWtg%erm and restrictions: RESTRICTIONS: Local Population Idertliticatton Card/Base Access Pass may only be used by person ktwhom they we Issued and tar the specitic business/purpose issued. Applicants are reminded that soliciting (I.e., daor1o400r sales) is prohibited an the base, and thai such activity Is grounds for cancellation of the Pass. Additionally such action may res.*t in debarment from the base and leqal action The Base Commanding officer baa discretion over specitying the penod of validity for any Local Population ID Carthdflase Access Passes that are tzued under his/her risdlckon, Review the Privacy At Statement that is printed at Inc lop of the torm Black 2: Enter the FksI Name, Black 3: Enter the Middle Name. Block 4: It applicable, check the box Ibm Name SuTtIx. Block ti: Check the applicable box for Hispanic or Latino, Black B: CbektheapptJcable box for Race Black 7: Check the applicable box for Gender. Block 11: Enter Date of Blrttt Block 9-1 Enter City of Birth, Block 10 Enter Slate of Birth. Black 11: Enter Country Or Bath. Block 12 Check the applicable box tar US Citizenship. Block IT ft no US Citizen, enter the name of the Country of Citizenship. Block 14: Two farms of dwinty source documents from the list of acceptable documents listed below must be presented to the base registrar with flits completed form, Check the box for the type of Documents thai will be presented tar Identity proofing. if the document type is not lated, use the two rows under Other Approved Identity Source Documents to enter the type of document(s) that you will present. Black iti: Enter the Document Number located on the IdentIty Prooting Source document that was checked in Block 14, Black 16 Enter the State that issued the identity Source Document Block 17: Enter the Country that issued the Identity Source Document, Block 19: Enter Inc Date Vial the Identity Source Document will expire. Block 22: Enter Weight in pounds. Block 21: Enter Height in Inches, Block 22: Check the applicable box fort-lair Color: Block 23: Check the applIcable box fbm Eye Color. Black 24: Enter flontre Address tnctadhg City, State, Zip Code, and Home Telephone Number, Black 23: Enter Name of Resirant's Base Sponsor and Base Sponsor's Telephone Block 25: Enter Employer Name and address Wtctuding City State, Zip Code, and Employer's Telephone Number. Black 27; Enter Supervisors Name including City, Slate, Zip Code, and Supervisor's Telephone Number, Block 25: Check the applicable box for Work Hours box on check the OTHER box and enter the work hours, then check applicable boxes fix' Work Days. Block 25: Check the applicable answer 111-you have been convicted of Felony and enter initials. Block 29: Check the applicable box far felony conviction, Block 30 Enter initials lo accept terms for returning Local Population Identification Ca BlocK 31: SIgn and date the form to attest that the tofegoing Information is true and complete to best Of your knowledge. LI STOP ACCEPTABLE DOCUMENT'S'.AII documents must not be expired. Must present one selection from List A ore eorrinstIon of one selection from UstB end one selection from LW C. LlstA - DooimentsthatEstabulshldentityand OR List S-. Documents that Establish Identity zJ.jr) List C- flocumentslflat Establish Employment Authorization Employment Authorlzatlon U.S, Passpertorli,S. Passport Card. Permanent Resident Card or Alien Registration Receipt Card (Form 1-551), Foreign passport that contains atemporary 1-551 stamp or terripacary, 1-551 printed notatIon on a machine- readable liuinitgrant visa. Emptoyrneni AuthorIzation Document that contains a photograph (Form 1-766) Fora nonimmigrant alien authorized to work for specific employer because of his or her status: L Foreign Passport and Form 1-94 or Form 1-94A that has the The same name as the passport and An endorsement Orthe alien's nonimmigrant status as long as that period of endorsement has not yet expired and the proposed employment is not in conflict with and restrictions or limitations kientifleti on lorm. Passport from the Federal States at Micronesia (ESM) or the Republic of the Marshal Islands (RM) with Form 1-94 or Form 1-9IA indicating nonlrnmlgrarli admission under the Compact 01 Free Association Between the united Stated and FSM omRM, Driver's license or It) card Issued bya State or outlying possession of the United States provided it contains a photograph or Wtbrmation such as name, date of birth, gender, height; eye color, and address, It) card issued by federal, state or local government agencies or entities, provided it containisa photograph or Information such as name, date of birth, gender, height; eye color, and address, School ID card with a photograph Voter's registration card. u.s. Mllitary card or dlatt recorti. Mllttary, dependent's U) card. U.S. Coast Guard Merchant Mariner Card, Native American tribal document Ddiier's license issued by a Canadian government authority. For persons underage 18 who are unable to present a document Isted above: to.. School record or report card. 11, C$nlc doctor, or, hospital record. 12 Day-care or nursery school record, 1. A Social Security Account Number card, unless the card lockides one of the following restrictions: NOT VALID FOR EMPLOYMEMT VALID FOR WORK ONY WITH INS AUTHORIZATION!, VALID FOR WORK ONLY WITH OHS AUTHORIZATION. 2, Cerlltication at Birth Abroad issued by the Department of State (Form FS-545), Certification of Biniti issued by the Departmental Slate (Form 05-1380),. Onlghial orcerlihled copy of birth certificate issued 17Y State, county, municipal authority or territory of the United States bearing an oliclal seat S. Native American tribal document S U.S. Citizen ID Card (Form I-IS?). identificatIon Card for Use of Resident Citizen in the United States (Form 1-179). Employment authorization document issued by the Department of Homeland Security. The remainder of the fbrm will be completed by the Base Registrar Person conducting Identify Proofing process and NCIC check. AGENCY DISCLOSURE STATEMENT The pub*c reporting burden for this collection of inkirmatlon is estimated to average 10 minutes per response, including the time for revIewing instructions, searching existing data sources, gathering and maintaining the data needed, and comp4etJrtg and reviewing the collection of Wt'onmation. Send comments regarding this burden estimate orariy other aspect of t:his collection orinfomiation, including suggestions for reducing the burden, to the oepartinentotoeftnse, Washington Keadiarters Services, Executive Services Dlreclarate, Information Management Division, 4800 Mark. Center Dove, East Tower, Suite 02309, Alexandrta, VA2235Tt-3100 0MB 0703.0061. Respondents MOM be aware that notwithstandIng any other provision Of law, no person shall be sublect to any penalty for falling to comply with a collection of information ii it does not display a currently valid OMB control number, PLEASE DO NOT RETURN COMPLETED FORM TO THE ABOVE ADDRESS, Completed form should be submitted to the Base Registrar. SECNAV 552/1 (APR 2514) FOR OFFICIAL USE ONLY WHEN FILLED. PRIVACY SENSITIVE; Page 3o1 3 Any misuse or unauthorized disclosure of this Information may result in both crimInal and civil penalties. OMB 0703.0061 F.xp. 31 Mar 2017 DEPARTMENT OF THE NAVY LOCAL POPULATION ID CARD/BASE ACCESS PASS REGISTRATION PRIVACY ACT STATEMENT AUTHORITY: IC) USC. 5013, Secretary of the Navy 10 U.S.0 5041, kuatem Maine Caps; ONAIP$T553C. 4E Navy Physic4 Sectgtty, Make Cope Order 5014A, Marine Corp P eur4y Prgrarn Man3; and EO. 9391 (SSN), as annded, SORM HMOSSI2..2, PURPOSEtS): To control pbysScat ascesalo Depadmenl of Defense (W), Depaflrneno4 the Navy (DOti) or U.S. Manna Carps tnalobtionWrib confratted Wwrnation, instalaona, facilities, or areas over w+ch Dot) DON or US Marine Cope has security re nabI,es by 4entitjnq or ven4iing an aidrr4a throui itia use of biometric databases and associated data procemingWorrnatm serwcas for designated 1ioesr purposes of protecting U.Soaiitia&aiad gevewmenaIeecur*y arm of responsibf ity and Information,to issue badges, replace teal badges, arid reiriee passes upon sepormiarK to Maintain Visitor aladets collect inlowmationtoa4dteate access to la(ft arid track the 001 y/ce*timeso( personnel. ROUTINE USE(S): 1odesIiated contractors, Federal agencles and thrnig qwarnrnvitskirthe purpose of granting KwyolaccesstQ thdr lacitty. DISCLOSURE. Pnwrkrig r tation iniormation ia voluntary.Failure topronde rerpestnd irtlemniaban may rmaft In dental of access to benefds pnidegas and J)et) ristalletrons acilbes and butkngs. IDENTITY PROOFING AND APPLICANT INFORMATION 1. LAST NAME 2, FIRST NAME., 3. MIDDLE NAME 4. NAME SUFFIX: Jr Sr II El III E Iv 5, HISPAN1C OR NO NAME MAW 6. RACE AFRICAN AMERFOWKTFIW AMERICAN INflIANOR OTHER RACIFIG LATiNO OR (Ctec*oneo,El moro):1:1 AIONMATIVE hsckoes) 7. [:]MALE LJFEMALEI Check 8 DATE OF BIRTH j 0 CITY OF BIRTH 10 STATE OF BIRTH [II BIRTH COUNTRY 12, US CITIZEN cteck: J YES LI NO 13, DUAL CITIZENSHIP, []YES F-INO I CITIZENSHIP IF OTHER THAN US (Country), U.S. Citizen MInimum Documentation Required; By Birth Social Security No and(ar Stale ID/Drivers License. Naturalized . Certification Number, Petition Number, Date, Place and Court; Umtad States passport number, Social Security No and/or State ID/Drivers License, Derived - Parenrs certification number, Social Security No and/ox State ID/Drivers License. Allen Minimum Documentation Required; Registration Number, Expiration data, Data of entry, Port of entry. 14. IDENTITY SOURCE DOCUMENTS PRESENTED: '15.. DOCUMENT NUMBER. 16, ISSUED BY STATE/COURT; 17, ISSUED BY COUNTRY; . IS U E EXPIRES: O Social Security No. United States O State ID/Drivers License United States O Port No, D Certification Number and Petition Niseber D Derived Parent's Certification Number. United States OAlien Restration No. United States Date of Entry; frort at Entry; OTHER APPROVED IDENTITY SOURCE DOCUMENTS: 20. WEIGHT 21, 1-IEIG1-IT 22, HAIR COLOR (cfleckane): 23. EYE COLOR (Check One): (Pounds): Blond Brown Black, Gray Red 0 Brawn J Green [I] Blue [] Hazel I LI WNW LII Silver LII Aibwn LI Bald [I] Black I Gray 1 Violet [] Unknown 24. I-tOME A IDRtSS (MM%M Owl stat; zip coft) hOME PhONE (lnctude Area (;otte): 20203 Elfin Forest Rd, Esconclido, CA, 92029 760'5204309 UASE SPONSOR'S NAME: SPONSOR P1'TQNE (!flcFu Area Code) Lt. Robert A. Winter NAVEAC CM 559-3144601 EMPLOYMENT ACTIVITY INFORMATON EMPLOYER NAME AND ADDRESS (mate,corft; EMPLOYER PFIONE anctrite Area Code): Soitek Pacific Construction, 2424 Congress Street, San Diego, CA. 92110 619-296-6247 21, SUPERVISOR NAME AND ADDRESS (inctUde cItafe/z code) SUPERVISOR PHONE (trtclucle Area Code): Ronald Hicks, 1080 Holland Ave. Clovis, CA. 93612 559-294-7101 SECNAV 5512/1 (APR 2014) FOR OFFICIAL USE ONLY WHEN FILLED - PRIVACY SENsrflVE: Page' 1 of 3 Any mtsuse or i.maultiorizod disciosure of this information may result; in both criminal and civil penalties. OMB 0703-0061 Exp. Si Mar 2017 28. Check the applicable box for WORK HOURS box or check the OTHER box and enter the work hours then check the applicable for WORK DAYS: WORK HOURS: J QQ-i1J Q8tJO1700 OTHER WORK DAYS: 7 SN M T W Th F ST PRIOR FELONY CONVICTIONS 29, Have you ever been convicted eta Felony? [jJvcs []NO REQUIREMENT TO RETURN LOCAL POPULATION ID CARD 30. I understand that I am reqwred to return ray Local Population Identification Card to the Base Pass Office when it expires or if my employment is terminated for any reason. _______ AUTHORIZATION AND RELEASE AND CERTIFICATION 51 t hereby authorize the DOD/DON and other authorized Federal agencies to obtain any information required from the Federal government and/or state agencies, incliudirig but not limited to the Federal Bureau of Investigation (FBI), the Defense Security Service (DSS), the U.S. Department of Homeland Security (OHS), I have been notified of DON right to perform minimal vetting and fitness determination as a condition of access to DON iest&Iation/facililies, I understood that I may request a record identifier, the source of the record end that I may obtain records from the State Low Enforcement Office as may be available to me under the iw. I also understand that this information will be treated as privileged and confidential information. I release any individual, including records custodians, any component of the U$.. Government or the individual State Criminal History Repository supplying Information, from alt liability for damages that may result on account oicornptiance, or any attempts to comply with this authorization, This release is binding now and in the future, on my heirs, assigns, associates, and personal repi osentatrve(s) of any nature Copies of this authorization that show my signature are as valid as the original release signed by me. FALSE STATEMENTS ARE PUNISHABLE BY LAW AND COULD RESULT IN FINES AND/OR IMPRISONMENT UP TO FIVE YEARS. BEFORE SIGNING THIS FORM, REVIEW IT CAREFULLY TO MAKE SURE YOU HAVE ANSWERED ALL QUESTIONS FULLY AND CORRECTLY. I DECLARE UNDER PENALTY OF PERJURY THAT THE STATEMENTS MADE BY ME, ON THIS FORM ARE TRUE, COMPLETE AND CORRECT DATE SIGNATURE_______________________________ FINAL DETERMINATION ON YOUR ACCESS: The Base Commanding Officer has final authority for determination on granting physical access to DON controlled instaations/facifities under his/her jurisdiction. BELOW COMPLETED BY BASE REGISTRAR PERSON CONDUCTING IDENTY PROOFING and NCIC CHECK 32, INFORMATION VERIFIED BY: 33. ENTERED IN C/S SYSTEM BY: 34. PASS ISSUE DATE: 35. PASS EXPIRATION DATE: 36. NCIC CHECK PERFORMED BY 37. RESULTS OF NCIC CHECK: 38. RESULTS OF LOCAL RECORDS CHECK: LINO RECORDS DRECORD IDENTIFIER LJNO RECORDS DRECORD IDENTIFIER RECORD NUMBER: RECORD NUMBER: Office of Under Secretary of Defense Directive-Type Memorandum (DTM) 08-012 "Interim Policy Guidance for Dot) Physical Access Control?' December 8, 2009. DTM 09012 requires that DOD Installation government representatives query the National Crime Information Center (NCIC) and Terrorist Screening Database to vet the claimed identity and to determine the fitness otnoMedenal government and non-DoD-issued card holders (i.e. visitors) who are requesting unescorted access to a DoD installation. The minimum criteria to determine the fitness of a visitor is: 1) not one terrorist watch list, 2) net on an DoD installation debarment list and 3) not on a FBI National Criminal Information Center (NCIC) felony wants and warrants hat Additionally, SECNAV Memo, Policy for Sex Offender Tracking and Assignment and Access Restrictions within the Department of the Navy, of Oct 08 and OPNAVINST 1752.3 established the Navy's policy on sex offenders, requiring Region Commanders (RE000MS) and lrstallalion Commanding Officers (COs) to prohibit sex offender access to DoN facilities and Navy owned, leased or PPV housing. This form describes the authority and purpose to collect and share the required information; and identifies the appllcanlMsitor and sponsor, and authorizes the Dot) to perform the minimum vetting and fitness determination criteria, A favorable response on the vetting and fitness determination is required to receive access to DOD-controlled instrillalion/facihties.. SECNAV 5512/1 (APR 2014) FOR OFFICIAL USE ONLY WHEN FILLED - PRIVACY SENSITIVE: Page 2 of 3 Any misuse or unauthorized disclosure of this iriformatkxi may result in both criminal and civil penalties. OMB 0703-0061 Exp. 31 Mar 2011 Instruction for completing the Local Population Access Registration Form INSTRUCTIONS: Please complete all information in black ink (printed) or by typing, Byvofontanly providing your Personal information, you agree to the following terms and restrictiorm: RESTRICUONS: Local Population identification Card/Base Access Pass may only be used by person to whom they are Issued and for the specific business/purpose Issued. Applicants are remindecithat sditcdtng (i.e,, door-todoor sales) is prohibited on the base, and that such activity Is grounds for canceltatlon 01 the Pass. Additionally, each action may resist Wi debarment from the base and legal action. The Base Commanding Officer has discretion over specifying the period or validity for any Local Papi4ahon ID Cards/Base Access Passes that are ssued underhtstberirisdlcton. Review the Prvacy At Statement that isprinted at the top of the form Block V Enter the Laof Name. Block 2: Enter the fksl Name. Block 3: Enter the Middle Name. Block 4: It applicable, chectr the box IV Name Suffix, Block 5: Che-k ttie applicable box for Hispanic or Latino. Block 6: Che:k the applicable box for Race. Block 7: Che:k the applicable box for Gender, Block a: Enter Date of Birth. Bloc: Enter city orown, 6Wik '10 Enter State al Birth. Block 11: Enter Country orsitlfi, Block 12: Check the applicable box for US citl2enship. Block 13: If nor a US Citizen, enter the name of Country of CitIzenship. Block. 14: TWO forms c4'l4erdity source documents from the 11Sf 01 acceptable docijmerits listed below must be presented to the base registrar With this complatO form, Check the box for the type of Documents that will be presented for identity proofing. if the document type is not listed, use Me PO rows under Other Approved Identity Source Documents to enter Me type of oocument(s) that you will present - Block 'IS: Elder the Document Number located on the Identity Proofing Source document that was checked in Block 14, Block 16: Enter the Slate that Issued the Identity Source Document, Block 17: Enter the Country that Issued the kierdity Source Document, Block IT Enter the Date that the Identity Source Document will expire. Stock 20: Enter Weight In pounds. Block 21: Enter Height In Inches, Stock 22: Check the applicable box for Flair Cofor. Block 25: Check the applicable box fOr Eye Color, Block 24: Enter Home Address Including City, State, lip Code, and Home Telephone Number. Block 25, Enter Name of Registran?s Base Sponsor and Base Sponsor's Telephone M*nber, Block 2& Enter Employer Name and address Iridkiding Ci1y State, lip Code, and Employers Telephone Plumber. Block 27: Enter Supervisor's Name inclumq City, State, ZIP Code, and Supervisor's Telephone Number, Block 2& Check the applicable box for Work Hours box or check the OTHER box and enter the work hours, then check applicable boxes for Work Days. Block 28: Check the applicable answer ii you have been convicted of Felony and enter lilitlals. Block 29: Check the applicable box for felony conviction, Block 30 Enter Initials to accept terms for returning Local Population Identification Card, Block SI: Sign and date the form to attest that the foregoing Information is true and complete lo best of your knowledge, LIST OF ACCEPTABLE DOCUMENTS -All documents rnustnot be expIred. Must present one selection from List A or a combinstion of one selection from List B and one selection from List C, List A- Documents that Establish Identity and OR List B Documents that Establish Identity AND List C - Documents that Establish EmployrnenlAuthorizatron Employment Ailliorlzatlon U.S. Passpc*tor U.S. Passport Card. Permanent Resident Card or Alen Registration Receipt Caro (Form 1-551). Foreign passport that contains a temporary 1-551 stamp or teriporary 1-551 printed notation on a mathirie-realatite immigrant visa, Employment Authorization Document that contains a photograph (Form 1-766). Fora nonimmigrant aten authorIzed to work for a speciticeriployer because of his or her status: Foreign Passport and Form 1-94 or Form 1-94A that has the followinq The same, name as the Passport and An erdorsement of the atterYs nonbemig,ant status as long as that period otenoorsemenlhas not yet expired and the proposed ernploymenl is not in cont'Jct With and restrictions or Imitations identifIed on lorm, Passport from the Federal Slates at Micronesia (ESM) ortlie Republic of the Marshal Islands (RM) with Form 1-94 or Form I-BaA indicating nonimmlgral-X admissIon under the Compact of Free Association Between the United Stated and FSM orRM. Driver's license or ID card Issued by State or outlying possession of the limited Stales provided It contains a photograph or irdbrmatlon such as name, date of birth, gender, height eye color, and address, II) card issued by tederal, state or local government agencies or entities, provided it: contains a photograph or information such as name, date of birth, gender, heignt eye color, anti address, School ID card with a photograph Votes's registration cant U.S. Military card or draft record, Military dependent's it) card. US. Coast Guard Merchant Mariner Cant Native American tribal document. Driver's license issued by a Canadian government authority. For persons under age 18 who are unable to present a document bled above: 10. School record or report card. 11, ClinIc, doctor, or hospital recant 12 Day-care or nursery school record. 1. A Social Security Account Number card, unless Me card Wtckides one of the following restrictions: (I) NOT VALE) FOR EMPLOYMEMT VALID FOR WORK ONY WIll-I INS AUTHORIZATION. VALID FOR WORK ONLY WITH DHS ALJWORIZATION. 2, Certification of Birth Abroad issued by the Department of State (Farm FS-545), 5, Certification ot Birth Issued bythe Department of State (Form QS-1360). 4. Original or certIfIed copy of birth certificate Issued by a Stale. ccuuritic municipal authority or territory 01 the United States bearing an official seat, S. Native American tribal document. U.S, Citizen ID Card (Form 1-194 identification Card for use at Resident Citizen In the hinted States (Form 1-179), B. Employment authorization document issued by Me Department-of Homeland Security. The remairnderofthe form will becornpleted bythe Base Registrar Person conducting Identify Proofing process and NClCcheck. AGENCY DISCLOSURE STATEMENT The public reporting burden for this collection of lnkzmal)on Is estimated to average tO minutes per response, including the Iline tar reviewIng instructions, searching existing data sources gathering and maintaining the data needed, and completing and revIewIng the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of Information, Including suggestions for rediucing tIne burden, lathe Department of Defonse, Washington Headquarters Services, Executive Services Directorate Wormatron Management Division 41100 MacK Center Drive East Tower SuIte 02009 AlexandrIa VA 22350-3100 OMB 070$-0061 Respondents should be aware that notwUhsfasxng any other provision or law, no person shall be subject to arty penalty for tailing to comply with a collection of Wr'orrnatlon lilt dries not display a currently valid 0MB control number: PLEASE DO NOT RETURN COMPLETED FORM TO THE ABOVE ADDRESS. Completed form should be submitted to the Base Registrar. SECNAV 5512/1 (APR 2014) FOR OFFICIAL USE ONLY WHEN FILLED - PRIVACY SENSITIVE: PageS of 3 Any misuse or unauthorized disclosure at this information may result in both criminal and civil penalties. A FfUz2-o -cc ( IAN ~Alk FIRE PROYCTION Fire Protection Contractor - License #989280 FIRE SUPRESSION MATERIAL SUBMITTAL ATEC 1950 CAMINO VIDA ROBLE, CARLSBAD, CA 92008 CONTRACT NO. 19572 2880 Scott Street, Suite 105- Vista, CA 92081 780-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page A ITAN FIRE PROTECTION Fire Protection Contractor - License #989280 TABLE OF CONTENTS SPRINKLERS OVERHEAD PIPE AND FITTINGS HANGERS AND SEISMIC VALVES OTHER 2880 Scott Street, Suite 105- Vista, CA 92081 760-2953881 - phone - 760-2953437 - fax www.fitanfpinc.com Page Page 1 of 6 MICROFAST® QUICK N411QNG4 III[Ui7If RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitivo glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used In decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts, LISTINGS AND APPROVALS e®us cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 () LPCB Approved: Certificate 096e106 WARNING; Cancer and Reproduadve Nanm www,P65Wamns.ce.ov CE Certified: Standard EN 12259-I, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 "F (-55 "C) Overall Length: 2-1/4" (58 mm) "cULus Listing, FM Approval, and NFPA 13 Installs require a minimum of 7 psi (0.5 bar), The minimum operating pressure for LPCB and CE Approvals ONLY Is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 "C) = A, 155 "F (68 "C) = B, 175 F (79 "C); D, 200 "F (93 "C) = E, 286 "F (141 "C) = G Form No, F_033314 19.10.14 Rev 19.2 Replaces Form No. F_033314 Rev 19.1 (Added ENT; updated FM language.) Page 2 of 6 41KIW4j MICROFAST11 QUICK lIIIuflUm7f RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384.5464 Fax: 269.818.1680 Email: techsvcs@vikingcorp.com Visit the Viking webslte for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No, 15915 (available since 2010) **A I/an ratchet Is required (not available from Viking). ***Allows use from the floor by attaching a length of 1 diameter CPVC tubing to the tool. Ideal for sprinkler cabinets, Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. S. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap— Figure 1: Standard Sprinkler Wrench 21475M!B Form No, F 033314 19.10.14 Rev 19.2 Page 3 of 6 N411QNG4 MICROFASTO QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color U Ordinary 135 F (57 C) 100 "F (38 "C) Orange Ordinary 155 °F (68 "C) 100 "F (38 "C) Red Intermediate 175 "F (79 "C) 150 "F (65 "C) Yellow Intermediate 200 "F (93 "C) 150 "F (65 "C) Green High 286 "F (141 "C) 225 "F (107 "C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 "F (57 "C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring Is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated, Sprinkler wrench 13655W/B** for recessed pendant sprinklers ** A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench fiats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No, F 033314 19.10.14 Rev 19.2 Page 4 of 6 Sj MICROFAST5 QUICK 1KI RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.viklnggroupinc.com Approval Chart I (UL) Tern The Viking Microfast Quick Response KE Pendent Sprinkler VK302 AX4-- Escutthen (if apphcabel Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals Part SIN K-Factor Length (Refer also to Design Criteria.)Style Number' _N PT 7BSP U.S.metric Inches mm cULus4 VdS LPCB C' 12979 VK302 Pendant 1/2' 15 mm 5.6 80.8 2-1/4 58 A1Z, B1Y, 02, C2X Al A1Z, BIY E-Cly Dl -• 19780 VK302 Pendent 1/2" -- 5.6 806 2-1/4 58 -- -. D3 21354 VK302 Pendant -- 15mm 5.6 80.6 2-1/4 58 - - -- D3 - 7rimz 2'Contacti Local 066628 VK302 Pendant 1/2" 15 mm 1 5.6 1 80.6 1 2-1/4 58 lAlZ,BlYD2,C2X -- - -- - 18021 VK302 Pendant 1 1/2" 1 15mm 1 5.6 1 80.6 1 2-1/4 58 AiX, BIY Al AIX, B1Y oix, CiY1 Dl Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 'C), 175°F 1 -Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 'C), 200 'F (93 'C), 286 'F (141 'C) Polyester',', Black Polyes- Viking MicromaticD Model E-1 Recessed Escutcheon 135 'F (57 'C), 155 'F (68 'C), 175 °F ter-' V - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 'C), and 200°F (93 'C) 2- ENT' Model E-1, E-2, or E-3 Recessed Escutcheon 155°F (68 °C), 175 'F (79 'C). and 3-Chrome Z- Standard surface-mounted escutcheon 200 'F (93 'C) 0-155°F (68 'C). 175°F (79 'C), 200°F (93 'C), 286 'F (141 'C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR.50021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfase Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be Installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No, F 033314 19.10.14 Rev 19.2 Page 5 of 6 N W4it MICROFAST5 QUICK lIl[iUu7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877.384-5464 Fax: 269.818-1680 Email: techsvcs@viklngcorp.com Visit the Viking web8ite for the latest edition of this technical data page: www.vlkinggroupinc.com Approval Chart 2 (FM) Temperature K EY The Viking Microfase Quick Response Finish Pendent Sprinkler VK302 A1X4- EscuttheonapphcabIe) Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals2 NPT up U.S. ii Number' Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 Rm11 it7V 80.6 2-1/4 1 58 AIZ, BIY, D2X, C2 71 i:ita widablifity (ColitTIRTY 0666213 VK302 Pendent 1/2' 15 mm 5.6 1 80,6 2-1/4 58 A1Z, BIY, D2X, C2 18021 VK302 Pendent 1/2' 1 15 mm 1 5.6 80.6 2-1/4 1 58 A1Z, B1Y Approved Temperature Ratings - - - - A - 135 OF (57 °C), 155 OF (68 'C), 175 F (79 'C), 200 OF Approved Escutcheons pp (93 'C) 286 'F (141 'C' Approved Finishes X - Standard surface-mounted escutcheon or the B - 135 OF (57 ), 155 OF (68 'C), 175 OF (79 'C), and 1 - Brass, Chrome, White Polyester", Viking Micromatic® Model E-1 Recessed Escutcheon 200 OF (93 -C) and Black Polyester4 - Standard surface-mounted escutcheon or recessed C - 155 'F(68 °C), 175 OF (79 'C), 200 OF (93 'C) 286 2 - ENT5 with the Viking Micromatie Model E-1 or E-2 Recessed Escutcheon D - 155 OF (68 C), 175 OF (79 'C), 200 OF (93 'C) I Z - Standard surface-mounted escutcheon I Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: The Viking MicrofastO Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.10.14 Rev 19.2 Page 6 of 6 N41 MICROFASP QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877.384-5464 Fax: 269.818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2.5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT\ L. - LT XK ]57 ____ 1(451flI) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-3/4" (45 mm) Max 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No, F033314 19.10.14 Rev 19.2 Replaces Form No, F 033314 Rev 19.1 (Added ENT; updated FM language.) Page 1 of 4 MICROFAST® QUICK '1 IIQNG SPRINKLER VK300 (K5.6) RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast5 Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used In decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant,) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. WARNING; C.ncsr wW R prodtctive Hwry wwwP65Ym1ng5.ccv 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated SrinkIers: Belleville Spring-Exposed For ENT Coated SrinkIers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfase Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 2 of 4 MICROFAST® QUICK N IF(III SPRINKLER VK300 (K5.6) l:II[.nuIyiyL RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135 °F (57 °C) 100 ¶ (38 C) Orange Ordinary 155 °F (68 °C) 100 ¶ (38 °C) Red Intermediate 175 °F (79 °C) 150 ¶ (65 °C) Yellow Intermediate 200 ¶ (93 C) 150 ¶ (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Form No. F_052114 18.10.11 Rev 17.1.P65 Page 3 of 4 rSIII(IF1i l:II[.11u.7M MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY I I Microfast® Quick Response + Firish AIX4 Escutcheon .f applicable) j Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals SIN Number1 ___________ NPT I BSP U.S. I metric2 Inches mm cULus I VdS LPCB I NYC I 12978 VK300 1/2" 15 mm 5.6 1 80.6 2-3/16 56 Al, B2 -- -- See footnote 7. F-" NOTIC8 - Prodiict Below w Litnited Availability (Contact Local Viking Officc) 06661B I VK300 1 1/2" 15 mm 5.6 80.6 2-3/16 56 - Al, B2 -- See footnote 7.1 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286 °F (141°C) 1 - Brass, Chrome, White Polyester' 6, and Black Polyester5'6 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA -UL (Also refer to Approval Chart I above.) The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Page 4 of 4 MICROFAST® QUICK 'ii 11UNG4 I:II[.q1.,yM RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY I Microfast® Quick Response j nish Fi A1X4 Escutcheon (itaPcabte)I Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT I BSP U.S. I metric2 Inches mm Number' (Refer also to Design Criteria below.) 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 JNOTICE J7T,I7T1Below Availability (Contact TILocal7A!11R1T 06661B VK300 1 1/2" 1 15 mm 1 5.6 1 80.6 1 2-3/16 56 f Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 - Brass Chrome, White Polyester5, and Black , er6 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyest 2- ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM ADoroval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 1 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT l:Il[w'iu.yM SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirages Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a tow- profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated In the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 WARNING: cancer and Reproductive Harm. www.P65Wamings.ca.gov VdS Approved: Certificate G4080021 RPM LPCB Approved: Certificate number 096e/12 CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) G MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending "cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'sj II(IIIG® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-Cl 1000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051 000 Cover Adapter: Cold Rolled Steel UNS-G1 0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-530400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 OF (68 °C) = B, 175 OF (79 "C) = D, 200 OF (93 "C) = E For example, sprinkler VK463 with a 155 OF (68 "C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 OF (57 "C) UL (139 OF (59 °C) FM and LPCB) =A, 165 OF (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 OF (74 °C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availbie with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 OF (57 "C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 "C) = C For example, cover 21876 with a 165 OF (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 "F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2 ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT '4s,jI IIiriG® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Nominal Ambient Temperature Rating of Cover Cover Plate Large Cover Square Cover Temperature Temperature Ceiling Assembly (Required) Base Part Plate Base Part Plate Base Part Bulb Cole Classification Rating' Temperature Number3 Number' Number3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135°F (57 °C) cULus 13504 or 218761 13642 or 218751 15394 Red 139 °F_(59_°C)_FM_ and _LPCB ____________ Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 21875 15394 Yellow Intermediate 200 °F (93° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 2187511 15394 Green Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings4: ENT Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts, These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers I Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Cha rt (UL) - - r- SpnnklerTenipecature RatingAprovaI Cover Plate Temperature Rating Mirages Concealed Pendent Sprinklers VK462 and VK463 AW1+ Cover Plate Finish KEY Sprinkler Thread Nominal Maximum Listings and Approval54 SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' Pressure Inch mm U.S. I metric? cULus' NYC I VdS7 LPCB Standard Response Applications 13503A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - -- AY1, CZ1 AY1, BZ1 AY1, CZ1' AY3 19785A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - -- - -- AY2,CZ2 21356A VK462 - 15 5.6 1 80.6 175 psi (12 bar) -- -- - -- - AY2,CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AV1,BX16 - - -- AY3 -- AS3, BT3 AV1, BX1, 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1' - - -- -- -- AS3, BT3 13667A VK463 1/2" 11 5 5 80.6 1250 psi (17.2 bar)3 AV1, BX1 I AV1, BX1 6 - -- -- -- -- Cover Plate Assembly Temperature Ratings"9 Sprinkler Temperature S - 135 °F (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes'0 Ratings T - 165 °F (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155°F (68 °C) °F °C) V - 135 (57 cULus Listed cover 13504, 13642 (large Brass, Brushed Brass, Brushed Copper, Painted White, diameter), or 15394 (square cover plate) B - 175 °F (79 °C) and 200 °F x - 165 °F (74 "C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 °C) Y - 135 °F (57 °C) cover 13504 LPCB Approved as 139 °F 2 - Brass C - 200 °F (93 °C) (59 °C) 3 - Stainless Steel Z - 165 °F (74 °C) cover 13504 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 +A1:2001 +A.2:2004 +A3:2006, Certificate G4080021. 10E Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40249. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. 12 MED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 5 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT sI IF(II1Gu SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) - cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS AeDroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN 12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 6 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT \,lIIKII41E® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Sprinkler Temperature Rating Cover Plate Temperature Rating Mirage® Standard Response Concealed Pendent Sprinkler VK462 AWI+ Covet Plate FinIsh KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals' Part No.' SIN I Water Working i (Refer also to Design Criteria below.) I Inch mm I U.S. I metric' I Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AW1, BX1, AY2, BZ2 Cover Plate Assembly Temperature Ratings1'4 Cover Plate Assembly Finishes5 Y - 139°F (59 °C) Cover 21875 or 21876 Sprinkler Temperature Ratings Z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175°F (79 °C) and 200 °F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. "The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM AoDroval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cLiLus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.10.11 Rev 18.2.P65 Page 7 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 4iII(IFs1EI SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap Sprinkler Wrench removed Use wrench Part No. 14047WB** 14047 WB** / Step 1: Carefully slide the wrench sideways around the deflector and pins 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047 WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) kler arms Sprinkler wrench fla 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum 2-1/16" (52 mm) -- - Minimum Ll _ i1ui 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F 103005 Rev 18.2 (Added P65 Warning.) COINO Sprinkler VK950 I 5.6K (80 metric) WARNING: Cancer and Repcductive Harm- www.P65WamIngs,ceov I of 13 COIN® QUICK SrjII(JI*1Gj® l:II[ruiyv. RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking QR COIN® Sprinklers are quick response specific application sprinklers for combustible interstitial (concealed) spaces (i.e., between floors, as well as low pitch attics that meet the criteria shown in the figures in this data page). These upright sprinklers are designed for use in specific light hazard combustible, as well as non-combustible, concealed spaces requiring sprinkler protection. The orifice design of the Viking QR COIN® Sprinkler, with a nominal K-factor of 5.6 (80 metric*), allows efficient use of available water supplies for hydraulically designed fire protection systems. The glass bulb operating element and special deflector combine speed of operation and area of coverage to meet the crucial fire protection requirement for shallow space combustible concealed spaces. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed/approved as indicated in the Approval Charts. FEATURES In some cases COIN® Sprinklers can allow the use of CPVC piping within the concealed spaces of applications requiring sprinkler protection in open truss construction of both wood and steel trusses (see Figure 3) and solid wood or composite wood joist with upper deck filled with non-combustible insulation (see Figure 5). COIN® Sprinklers can also be installed with steel pipe in protected areas constructed of solid wood joists (see Figure 6), and solid wood or composite wood joist with upper deck filled with non-combustible insulation (see Figure 7), and in unobstructed open truss construction of both wood and steel trusses (see Figures 8 and 9) as well as obstructed wood truss construction (see Figure 10). When using steel pipe, COIN® Sprinklers can be applied as a dry system using air or gas as a supervisory medium (see Figures 6-10). In certain scenarios, draft curtains are NOT required when sprinkler spacing meets either of the following criteria (also refer to Design Criteria): - 14'X 14' (4,3 m X 4,3 m) for solid wood joists or trusses on edge - 16'X 16' (4,9 m X 4,9 m) for truss construction on face (not on edge) For examples of trusses on face or edge see Figures hA and 11 B. 2. LISTINGS AND APPROVALS ceus cULus Listed: Category VNIV Refer to the Approval Chart and Design Criteria in this technical data sheet for cULus Listing requirements that must be followed. The COIN® Sprinkler has been tested to address the proper application density for shallow concealed combustible space fire protection when installed in accordance with this technical data page. The COIN® Sprinkler must be installed in the upright position as specified in the appropriate application described in Figures 3-10. The clearance from the sprinkler deflector to the roof is critical to operation of the sprinkler (refer to Figures 3-10). The clearances from pipe to lower ceiling for CPVC pipe is critical for protection of CPVC pipe. For open truss and joist spaces, the maximum detection area is important for proper installation. In certain installations, draft curtains or heat collection baffles or solid walls are required using wood or other product that will not allow heat to escape. In these installations, the maximum detection space shall be limited to 1000 ft' (93 m2) or 2000 ft2 (185 m2) for solid wood joists. The draft curtain is required to protrude down from the top deck surface as specified herein. Additionally, draft curtains are not required and the maximum detection space shall be unlimited for open truss construction with the top chord member on their face (not on edge) when sprinkler spacing is up to 16' X 16' (4,9 m X 4,9 m) and for solid wood joists or trusses on edge when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m). In these cases, draft curtains are not required. Form No. F ..081216 20.01.09 Rev 20.1 Replaces Form No. F081216 19.2 (Added draft curtain exception criteria) 2 of 13 COIN® QUICK RESPONSE UPRIGHT N41vj-;Fs1 SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to Design Criteria in this technical data sheet. Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-1/4" (57 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Ordering Information: (Also refer to the current Viking price list.) Order the QR COIN® Sprinkler by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number 20757. Available Finishes And Temperature Ratings: Finish Suffixes: Brass = A, ENT = JN Temperature Suffixes: 200 OF (93 °C) = E For example, sprinkler VK950 with a Brass finish and a 200 OF (93 °C) temperature rating = Part No. 20757AE Accessories: (Also refer to the Viking Website) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During a fire condition, the heat sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern to extinguish or control the fire, and protect the piping in the interstitial space. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking QR COIN® Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F081216 20.01.09 Rev 20.1 3 0113 COIN® QUICK RESPONSE UPRIGHT F'1G SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1 :AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Intermediate 200 ¶ (93 °C) 150 °F (65 °C) Green Sprinkler Finish: Brass, ENT' Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all the possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, Including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Approval Chart Temperature KEY Firrsh COIN® Specific Application QR Upright Sprinkler VK950 +- (it appiicable)j For Light Hazard Occupancies Only Part Maximum I Thread Size I Nominal Overall Length Listings and Approvals3 Number 1 SIN I Pressure I K-Factor I I (Refer also to Design Criteria.) I I NPT I BSPT I U.S. I metric2 Inches I mm I cULus' 20757 VK950 175 psi 1/2" 15 mm 5.6 80 2-1/4 57 Al Approved Temperature Rating Approved Finish A - 200 ¶ (93 °C) I - Brass, ENT' Footnotes 1 Also refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. Meets New York City requirements, effective July 1, 2008, 5cULus Listed as corrosion resistant, Wrench Fiat Protective clip Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F081216 20.01.09 Rev 20.1 1-3/4' I4-(45mm) J 2-1/4" (57 mm) IF t 7/16" (11 mm) 1,'2"1PNPT Nominal pipe engagement (15mm) Figure 2: Sprinkler Dimensions 4 of 13 iq 11MMS COIN® QUICK RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - CPVC PIPE (See Figures 3-5) (Also refer to the Approval Chart on page 3.) The Viking COIN® Sprinkler MUST be installed in the upright position. APPLICATION For installation in horizontal interstitial concealed spaces constructed of engineered open wood trusses, open bar joist, and non-combustible insulation completely filling the upper joist for solid or composite wood joist construction having roof pitch of up to 2/12. NOTE: In order to be considered "non- combustible insulation filled solid wood or composite wood joist construction", the insulation (including insulation provided with a combustible vapor barrier), must completely fill the pockets between the joists to the bottom of the joists, and the insulation must be secured in place with metal wire netting. The metal wire netting is intended to hold the insulation in place should the insulation become wetted by the operation of the CO//V1 Sprinklers in the event of a fire. A. Concealed Space Limitations The total concealed space is not limited; however, the following must be observed: Draft curtains (heat collection baffle) or full height walls must be provided to limit the maximum area in order to confine heat of localized detection area to 1000 ft2 (93 m2) or, for solid wood joists and open truss construction with the top chord members on face (not on edge) to 2000 ft2 (185 m2). Insulated top chord spaces (on edge) confine heat localized detection area to 2000 ft2, non-insulated top chord spaces (on edge) confine heat local- ized area to 1000 ft2 (93 m2). The draft curtain must be at least 1/3 the depth of the concealed space or 8" (200 mm), whichever is greater, for open truss construction, open bar joist, and non-combustible insulation filled solid or composite wood joist construction. The draft curtain must be constructed of material that will not allow heat to escape through or above it; this may be '/4" (6 mm) thick plywood. Draft curtains are NOT required when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m) for solid wood joists or trusses on edge; see Figure 11B. Draft curtains are NOT required when sprinkler spacing is up to 16'X 16'(4,9 m 4,9 m)for truss construction on face (not on edge); see Figure 11 A. B. Concealed Space Height Open Wood Truss and Open Steel Joist Construction (Figure 3): Maximum height of the space: 60" (1.5 m). Minimum height: 6" (150 mm) Maximum roof pitch: 2/12 (9°) Where applied to pitch roof and flat ceiling, maintain specified clearances from sprinkler deflector to truss and maximum height of pipe run to ceiling or non-combustible ceiling insulation in all locations. NOTE: The sprinkler deflector shall be installed parallel with the roof plane. Solid wood or comoosite wood ioist with non-combustible filled insulation only (Figure 5): Maximum depth of concealed space is 60" (1500 mm) from bottom of upper deck joist to top of ceiling joist. Minimum depth is 6" (152 mm) from bottom of upper deck joist to top of ceiling joist or non-combustible ceiling insulation. C. System Type Light Hazard, Wet Pipe System D. Minimum Density 0.10 gpm/ft2 (4.1 mm/mm). E. Spacing of COIN® Sprinklers Minimum Spacing: 6-0(1.8 m) Maximum Spacing: 16-0" (4.9 m) NOTE: Minimum spacing does not include additional sprinklers required for obstructions for use of CPVC pipe that includes offsets. F. Maximum Area of Coverage 256 ft2 (24 m2) G. Minimum Operating Pressure 7.0 PSI (0.5 bar) H. COIN® Sprinkler Deflector Position The COIN® Sprinkler shall be installed in the upright position. The frame arms must be installed parallel with the pipe. 1-1/2" to 4" (40 - 100 mm) below upper deck for Open Wood Truss and Open Steel Open Joist Construction Using CPVC Pipe (see Figure 3). 1-1/2" to 4" (40 - 100 mm) below non-combustible insulation-filled upper deck for Open Wood Truss and Open Steel Open Joist Construction with Using CPVC Pipe (see Figure 4). 1-1/2" to 4" (40 - 100 mm) below non-combustible insulation-filled solid wood joists or composite wood joists (see Figure 5). on Form No. F081216 20.01.09 Rev 20.1 5 of 13 COIN® QUICK RESPONSE UPRIGHT N41KJNG4 SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikingqroupinc.com DESIGN CRITERIA -CPVC PIPE (See Figures 3-5) (Also refer to the Approval Chart) (continued from page 4.) I. Remote Area For wet pipe systems, 1 The remote area for open wood truss construction or open bar joist construction with the top chord members on face (not on edge) is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 16'X 16 (4,9 m X 4,9 m). The remote area for this application is the same as above. 2. The remote area for solid wood joists is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m). The remote area for this application is the same as above. 3. The remote area for open wood truss construction with the top chord members on edge is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m) The remote area for this application is the same as above. 4. The remote area for composite wood joists is 1000 ft2 (93 m2). NOTE: This area does not include additional sprinklers for protection of CPVC pipe over obstructions. J. UL Listed CPVC Pipe for use with COIN TM Sprinklers The Viking COIN® Sprinkler is UL Listed for use with CPVC pipe products listed for use in concealed spaces with sprinklers**. **Currently listed products are manufactured under the BlazeMaster, FireLock®, and FlameGuard® trade names. In order to use CPVC products, the bottom of the horizontal run must be no greater than 6" (150 mm) or 1/3 of the total space, whichever is smaller, above the ceiling or non-combustible insulation or 1/3 the depth of the space measured from the top surface of the ceiling to the bottom of the deck above. The CPVC pipe can supply the COIN® Sprinklers and the ceiling sprinklers below. Use all guidelines and installation instructions as specified by the CPVC pipe manufacturers unless specified differently in this data sheet. When using 1" (DN25) pipe or larger, a hanger must be located at the truss nearest the sprig for restraint. If using 1/4" (DN20), all sprigs over 12" (300 mm) must include lateral bracing. For use of listed CPVC pipe products in concealed spaces using the COIN® Sprinkler, a minimum lateral distance of 18" (450 mm) must be maintained between the CPVC pipe and the heat sources (e.g. HVAC heat pump units, fan motors, and heat lamps, etc.) Where CPVC pipe must be installed above the maximum distance of 6" (150 mm) or 1/3 of the total space, whichever is smaller, above the ceiling or non-combustible insulation when piping around obstructions, additional COIN® Sprinklers must be installed as shown in Figures 3, 4, and 5 in order to protect the CPVC product. Ft. (m) All values TABLE 0.1 2: PRESSURE VS. ity COVERAGE PSI (bar) MATRIX I 16(48) 7(04) 72(04) 82(05) 10.3 (0.7) 14.1 (0.9) 169(11) 184(12) 216(14) 15(4.5) 7(0.4) 7(0.4) 7.2 (0.4) 9.2 (0.6) 12.8(0.8) 14.1 (0.9) 16.9(1.1) 18.4(1.2) 14(4.2) 17(0.4) 170.4 7(0.4) 8.2(0.5) E(O.8) 11.5(0.7) 12.8(0.8) 14.1 (0.9) 16.9(1.1) 13(3.9) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 9.2(0.6) 11.5(0.7) 12.8(0.8) 14.1 (0.9) 12(3.6) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 8.2 (0.5) 9.2 (0.6) 10.3 (0.7) 12.8 (0.8) 11(3.3) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 8.2 (0.5) 9.2 (0.6) 10.3 (0.7) 10(3.0) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7.2 (0.4) 8.2 (0.5) 9(2.7) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7.2 (0.4) 8(2.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) 7(0.4) Ft. (m) 8(2.4) 9(2.7) 10 (3.0) 11(3.3) 12(3.6) 13(3.9) 14(4.2) 15(4.5) 16(4.8) NOTES: This table applies to heat collection areas of 2000 ft2 (185 m2) and greater (unlimited). Design areas between table spacing values need to be rounded up. This table does not apply to heat collection areas of 1000 ft2 (93 m2). Form No. F_081216 20.01.09 Rev 20.1 6 of 13 .UIN' !lLJftt't RESPONSE UPRIGHT 'J 11(1 m e SPRINKLER (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com j- TOP AND BOTTOM CHORD ON EDGE FOR / DRAFT CURTAIN (HEAT COLLECTION / BAFFLE) OR FULL HEIGHT WALL WHEN / LOCALIZED DETECTION AREA IS A MAXIMUM 1000 SO FT. 193 SO. METERS) UPPER DECK 1-1/2' (40 ) MINIMUM 1 4' (100 -,-MAXIMUM - - - - - - - - - - -- ------------------ 6' (150 (HEAT COLLECTION I I WHICHEVER IS MAXIMUM FOR CPVC PIPE DRAFT CU BAFFLE) 8' (200 mm) I I OR HEIGHT. II GREATER 4-1/2' (115 mm) MINIMUM FROM FACE OF WOOD TRUSS OR TOP CHORD OF BAR JOIST. TOP CHORD 4' (100 mm) OR LESS. ,- COIN SPRINKLER JF I - - - - - - - - - 11 - - - M-A _XINUN_. OBSTRUCTION CEILING I / BOTTOM OF PIPE ' L_ 6' (150 mm) MAXIMUM CLEARANCE FOR CPVC PIPE FRAME ARMS OF -' SPRINKLER MUST BE WHEN CPVC PIPE IS INSTALLED -/ OVER OFFSET. COIN SPRINKLER TO CEILING OR NON-COMBUSTIBLE CEILING INSULATION, OR 1/3 ACTUAL SPACE (MEASURED INSTALLED PARALLEL MUST BE INSTALLED DIRECT TO FROM THE TOP SURFACE OF THE CEILING TO THE WITH PIPING CPVC PIPE OVER OBSTRUCTION. BOTTOM OF THE DECK ABOVE) WHICHEVER IS SMALLER 14' (100 mm) FOR 12' (300 mm) TRUSS]. Figure 3: Open Wood Truss and Open Web Steel Joist Construction Using CPVC Pipe (Cross Section View) TOP AND BOTTOM CHORD ON EDGE FOR DRAFT CURTAIN (HEAT CEILLEMON BAFFLE, OR FULL HEIGHT WALL WHEN 4-1/2' (115 mm) MINIMUM FROM LOCALIZED DETECTION AREA IS A FACE OF WOOD TRUSS OR TOP INSULATION MAXIMUM 2000 SO FT. (185 SO. METERS) CH13RO OF BAR JOIST. UPPER BE TOP CHORD GREATER /-F 4' (100 ") MAXIMUM /_ COIN SPRINKLER DRAFT CUR AIN MAXIMUM FOR (HEAT COLLECTION CPVC PIPE 6' (150 MM) MINIMUM, 60' (1500 MM) BAFFLE) 8' (200 mm) MAXIMUM. OR I HEIGHT, WHICHEVER IS / / BOTTOM OF PIPE - - 6' (ISO mm) MAXIMUM CLEARANCE FOR CPVC PIPE CEILING FRAME ARMS OF -' WHEN CPVC PIPE IS INSTALLED ." TO CEILING OR NON-COMBUSTIBLE CEILING SPRINKLER MUST DX OVER OFFSET. COIN SPRINKLER INSULATION, OR I/S ACTUAL SPACE (MEASURED INSTALLED PARALLEL MUST BE INSTALLED DIRECT TO FROM THE TOP SURFACE OF THE CEILING TO THE WITH PIPING CPVC PIPE OVER ORSTRUCTIQfL BOTTOM OF THE DECK ABOVE) WHICHEVER IS SMALLER (4' (100 mm) FOR 10' (300 mm) TRUSS). Figure 4: Open Wood Truss and Open Web Steel Joist Construction with Non-Combustible Insulation Filling to Bottom of the Top Cord Using CPVC Pipe (Cross Section View) Form No. F081216 20.01.09 Rev 20.1 7 of 13 COIN® QUICK N II(IIs1G ® l.I:IIE•qM RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com FRAME ARMS OF COIN SPRINKLER UPPER CLEARANCE SPRINKLER TO MUST BE PARALLEL WITH PIPING DECK BOTTOM JOIST 1-1/2' (40 mm) NON-COMBUSTIBLE MINIMUM, 4' (100 mm) MAXIMUM INSULATION — ••1•••! I •' I S.....f I I .'..... ID•••e•.u,•••s•I,...'a•I•••... ...... ,••••• I.....l ________ I..........,. ii.•.•.•.s.• •.•.•.•.•.•& •..'.'.'.. •••I I.•..•.• -COMPOSITE MAXIMUM SPRINKLER 2 X FLOOR JOIST DRAFT CURTAIN (HEAT COIN -PIPE SOLIDJ COLLECTION BAFFLE) MAX. PROTRUDE BELOW SPRINKLER MAXIMUM AS NOTED IN DESIGN CRITERIA CEILING uI.l1IlSIlIu CEILING FRAME l TOP .I CHORD Il WHEN CPVC PIPE INSTALLED J OVER OFFSET, COIN SPRINKLER 6' (1500mm) MAXIMUM MUST BE INSTALLED DIRECT TO CLEARANCE FOR CPVC PIPE T CEILING OR CPVC PIPE OVER OBSTRUCTION NON-COMBUSTIBLE CEILING INSULATION, OR j ACTUAL SPACE, WHICHEVER IS SMALLER MEASURED FROM THE TOP OF THE CEILING BELOW TO THE BOTTOM OF THE INSULATION ABOVE. Figurei-1 If Insulation Filling Upper Deck Using CPVC Pipe (Cross Section View) Form No. F081216 20.01.09 Rev 20.1 8 of 13 COIN® QUICK RESPONSE UPRIGHT .iIF(1FsJG SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA -STEEL PIPE (See Figures 6-10) (Also refer to the Approval Chart on page 3) The Viking COIN® Sprinkler MUST be installed in the upright position. APPLICATION For installation in horizontal concealed spaces of solid wood joist construction with a roof pitch of up to 2/12 maximum. The upper joist is constructed of solid wood or composite wood with a maximum depth of 12" (300 mm) and 16" (400 mm) on center minimum spacing. Also, steel pipe may be ap- plied in truss construction and solid filled non-combustible insulation in upper deck and wood or composite joist construction similar to that shown in Figures 3-5 with the exception of extra sprinklers are not required over obstructions. Also, there is no minimum clearance for supply pipe to upper joists. With the COIN® Sprinkler applied using steel pipe, the system may be wet, dry, or preaction type for wood truss or steel construction; solid wood or composite with non-combustible solid fill insulation (see Paragraph J on page 9). NOTE: In order to be considered "non-combustible insulation filled solid wood or composite wood joist construction", the insulation (including insulation provided with a combustible vapor barrier), must completely fill the pockets between the joists to the bottom of the joists, and the insulation must be secured in place with metal wire netting. The metal wire netting is intended to hold the insulation in place should the insulation become wetted by the operation of the COMP Sprinklers in the event of a fire. A. Concealed Space Limitations The total concealed space is not limited; however, the following must be observed: Blocking between joists and upper deck must be constructed of material that will not allow heat to escape through or above the blocking. The blocking must be constructed to the full depth of the upper joist, and must be constructed using a non-combustible material or a material that is the same as that of the joist construction. A maximum channel space for blocking is 32 ft (10 m) intervals. Solid wall construction or draft curtains (heat collection baffles) must protrude below the joist a minimum of 6" (150 mm) or 1/3 the space, whichever is greatest, and run laterally with the joist spaced at 31 ft (9.4 m) width maximum to limit the heat detection space to a maximum of 1,000 ft2 (93 m2) or with the truss spaced at 62 ft (19 m) width maximum to limit the heat detection space for open wood truss construction to 2000 ft2 (185 m2) with their top chord members on face (not on edge) and 2000 ft2 (185 m2) for solid wood joists. Insulated top chord spaces (on edge confine heat localized detection area to 2000 ft2 (185 m2), non-insulated top chord spaces on edge confine heat localized area to 1,000 ft2 (93 m ). The draft curtain may be constructed of 1/4" (6 mm) thick plywood to prevent heat from escaping beyond. When non-combustible solid filled insulation is used, the wood blocking and draft curtains are not required for solid wood or composite wood joist construction. Draft curtains are NOT required when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m) for solid wood joists or trusses on edge for wet systems only; see Figure 11B. Draft curtains are NOT required when sprinkler spacing is up to 16'X 16' (4,9 m X 4,9 m) for truss construction on face (not on edge) for wet or dry systems; see Figure hA. B. Concealed Space Height Solid Wood or Composite Wood Joist Construction (See Figures 6 and 7): Maximum depth or height of concealed space: 60" (1500 mm) from bottom of upper deck joist to top of ceiling joist. Maximum space from bottom of upper deck to ceiling surface (bottom of joist): 84" (2100 mm). See Figure 6. Minimum depth or height of concealed space: 6" (150 mm) from bottom of upper deck joist to top of ceiling frame joist. Open Wood Truss or Open Web Steel Joist (See Figure 8): Maximum height from inside ceiling to inside deck of concealed space: 60" (1500 mm). Minimum height from bottom of upper chords to top of lower chords: 6" (150 mm) The top and bottom chord members of these types of wood joists must be on face (not on edge). Obstructed Wood Truss (See Figure 10): Maximum depth of concealed space: 84" (2100 mm) from bottom of upper deck to top of ceiling. Minimum depth of concealed space: 6" (150 mm) from bottom of upper chord to top of lower chord. System Type Light hazard, wet pipe system or dry pipe system supervised with air or gas when using steel pipe only. Minimum Density 0.10 gpm/ft2. (4.1 mm/mm). Spacing of COIN® Sprinklers Minimum Space Between Sprinklers: 6-0" (1.8 m) Maximum Space Between Sprinklers: 16'-0" (4.9 m) F. Maximum Area of Coverage 256ff2 (24 m2) G. Minimum Operating Pressure 7.0 PSI (0.5 bar) H. COIN® Sprinkler Deflector Position The COIN® Sprinkler shall be installed in the upright position. The frame arms must be installed parallel with the pipe. 1-1/2" to 2" (40 - 50 mm) below solid wood joist or top chord of obstructed wood truss construction. See Figures 6 and 10. 1-1/2" to 4" (40- 100 mm) below upper deck for unobstructed open wood truss construction or concealed spaces of non-combustible open steel joist construction. See Figures 8 and 9. 1-1/2" to 4" (40 - 100 mm) below non-combustible insulation-filled solid wood joists or composite wood joists. See Figure 7. (continues on page 9.) Form No. F_081216 20.01.09 Rev 20.1 9 of 13 N4 SPR COIN® QUICK INKLER VK950 I KJ lil:IIEu.yM RESPONSE UPRIGHT WJ (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - STEEL PIPE (See Figures 6-10) (Also refer to the Approval Chart on page 3) (continued from page 8) I. Remote Area For wet pipe systems, 1. The remote area for open wood truss construction or open bar joist construction with the top chord members on face (not on edge) is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 16'X 16 (4,9 m X 4,9 m). The remote area for this application is the same as above. 2. The remote area for solid wood joists is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m). The remote area for this application is the same as above. 3. The remote area for open wood truss construction with the top chord members on edge is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 14'X 14' (4,3 m X 4,3 m) The remote area for this application is the same as above. 4. The remote area for composite wood joists is 1000 ft2 (93 m2). For dry pipe systems, 1. The remote area for open wood truss construction or open bar joist construction with the top chord members on face (not on edge) is 1000 ft2 (93 m2) or 6 sprinklers, whichever is greater. See Table 2. Draft curtains are NOT required when sprinkler spacing is up to 16'X 16' (4,9 m X 4,9 m). The remote area for this application is the same as above. The remote area for solid wood joists is 2000 ft2 (185 m2) or 15 sprinklers, whichever is greater. See Table 2. The remote area for open wood truss construction with the top chord members on edge is 1000 ft2 (93 m2). The remote area for composite wood joists is 1000 ft2 (93 m2). J. Piping System Steel pipe installed in accordance with NFPA 13 standards may be applied. The steel pipe may be hung from the upper joist or truss using proper supports. The sprinkler deflector must be positioned as indicated in paragraph H above. Extra sprinklers are not required for protection of pipe when offsetting for obstructions. Ceiling sprinklers below the concealed space may be fed from the same piping as the COIN® Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 . Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. UPPER DECK CLEARANCE SPRINKLER TO BOTTOM JOIST 1-112' (40 MINIMUM. 2' (50 ,,,) MAXIMUM FRAME ARMS OF COIN SPRINKLER MUST BE PARALLEL '.11TH PIPING 2 X FLOOR JOIST ---------COIN BLOCKING SPRINKLER (150 MINIMUM 84 MAX. TO 60' (15OO) MAXIMUM (2100 ) 1) -6 DRAFT CURTAIN (HEAT 1 COLLECTION BAFFLE) CEILING PROTRUDE BELOW JOIST CEILING FRAME SPACE OR 6 (150 AS NOTED IN DESIGN CRITERIA Figure 6: Solid Wood Joist Construction (Steel Pipe, Cross Sectional View) Form No. F081216 20.01.09 Rev 20.1 10 of 13 COIN® QUICK "J IIIrs1E® RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com __;.;. SOLIDWOOD COMPOSITE COIN 72' (1100 M') 2 X FLOOR JOIST WOOD JOIST SPRINKLER MAXIMUM \ CEILING —" \ FRAME CEILING Figure 7: Solid Wood or Composite Wood Joist Construction with Non-Combustible Insulation Filled Upper Deck (Steel Pipe, Cross Sectional View) TOP CHORD 4' (100 'n) OR LESS UPPER DECK CLEARANCE SPRINKLER TO DECK 1-1/2' (40 ) MINIMUM 4' (100 ,,) MAXIMUM 4-1/2' (115 n,) MINIMUM FROM FACE OF WOOD TRUSS OR TOP CHORD OF BAR JOIST WHEN CLEARANCE OF SPRINKLER TO DECK IS LESS THAN 4' (100 COIN SPRINKLER -,. - - - - - - - - - - TT1" I L ;)Th"" '-• FRAME ARMS OF SPRINKLER DRAFT CURTAIN (HEAT MUST BE PARALLEL WITH PIPING 60' (1500 ,r) MAXIMUM COLLECTION BAFFLE) 8' '- CEILING "- SPRINKLER FOR (210 ,w,) OR HEIGHT, \ LOWER ROOM AS NOTED IN DESIGN CRITERIA \ PROTECTION OPEN WOOD OR STEEL TRUSS CONSTRUCTION CONCEALED SPACE. Figure 8: Unobstructed Open Wood Truss and Open Steel Bar Joist (Steel Pipe, Cross Sectional View) Form No. F_081216 20.01.09 Rev 20.1 11 of 13 IIIFI NG ® COIN® QUICK A III[sViUI7f RESPONSE UPRIGHT iIJ SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TOP CHORD FROM FACE OF WOOD TRUSS GREATER THAN OR T13P CHORD OF BAR JOIST UPPER DECK CLEARANCE SPRINKLER TO BEITTOM,11 CHORD WHEN CLEARANCE OF SPRINKLER TO DECK IS LESS THAN 4' (SOD mj~) 4'(100 - 1-1/2, 40 mm) MINIMUM 41 (IQQ ~m) MAXIMUM F COIN SPRINKLER V V V ;9 UDT:SDRX•OO.iD R'MIN B MM) I I 60' (1000 I I ) IMUM MAXIMUM. _ 4 DRAFT CURTAIN (HEAT COLLECTION BAFFLE) 8 FRAME ARMS OF SPRINKLER (000 mp) OR j HEIGHT MUST BE PARALLEL WITH PIPING AS NOTED IN DESIGN CRITERIA CEILING - OPEN yOGI OR STEEL TRUSS CONSTRUCTION CONCEALED SPACE SPRINKLER FOR LOVER ROOM PROTECTION Figure 9: Open Wood Truss and Open Web Steel Joist Construction with Non-Combustible Insulation Filling to Bottom of the lop Cord Using Steel Pipe (Cross Section View) TOP CHORD FRAME ARMS OF SPRINKLER GREATER THAN MUST BE INSTALLED PARALLEL 4 <110 ,,) DEEP 1-1/2 (40 ) MINIMUM UPPER DECK / WITH PIPING 2 (50 ,.n) MAXIMUM 84 60' (1 500 MAXIMUM MAXIMUM. 6' (150 ,,,,) MINIMUM. (21X0 CEILING FRAME _7 H N N CEILING Figure 10: Obstructed Wood Truss Construction (Steel Pipe, Cross Sectional View) Form No. F 081216 20.01.09 Rev 20.1 12 of 13 COIN® QUICK '"iJ IKI I1Gi RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com VISIt the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com \ir On Face 3.1/2" 8i min) Example of Typical 2x4 Construction Refer to Design Critera Figure hA: Trusses on Face 1.1/2" (38 mm) On Edge Example of Typical 20 Construction Refer to Design Critera Figure IIB: Trusses on Edge Form No. F081216 20.01.09 Rev 20.1 13 of 13 iNIMMg COIN® QUICK RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION) The Viking Corporation, 210 N industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking webslte for the latest edition of this technical data page: www.vikinggroupinc.com OBSTRUCTION CRITERIA -_CPVC and STEEL PIPE APPLIES TO BOTH CPVC AND STEEL PIPE (Also refer to the Approval Chart) OBSTRUCTIONS All obstruction criteria for extended coverage sprinklers per NFPA 13 shall apply unless specified differently in this data sheet. See illustrations below. X 2t 4Y or 4Z X < 36" (900 mm) (Use dimension V or Z, whichever Is greater.) ELEVATION VIEW PLAN VIEW Upper OeK Lower Dech Figure 12A: NFPA 13 Obstruction Criteria ELEVATION VIEW Upper Deck or bottom of non-combustible Insulation Distance from Sprinkler ObstrUction <1-0" to Side of (X) <300 mm Maximum Allowable Distance of Deflector Above Bottom of Obstruction (Y) 0" 0 mm 1-0" to <1-6" 300 mm to <450 mm 0" 0 mm 1-6" to <2'-O" 450 mm to <600 mm 1" 25 mm 2-0" to <2-6" 600 mm to <750 mm 1" 25 mm 2-6" to <3-0" 750 mm to <900 mm 1" 75 mm 3'-O" to <3'-6" 900 mm to <1.1 m 3" 75mm- T-6" to <4-0" 1.1 mto <1.2 m 3" 75 mm 4-0" to <4-6" 1.2 m to <1.4 m 5" 125 mm 4'-6" to <5-0" 1.4 m to <1.5 m 7" 175 mm Figure 1213: NFPA 13 Obstruction Criteria Table 11.2.5.1.2 Form No. F_081216 20.01.09 Rev 20.1 Replaces Form No. F_081216 19.2 (Added draft curtain exception criteria) TABLE I SPRINKLER GENERAL INFORMATION Item Description Sprinkler Identification Number (SIN) VK5I0 K-factor, gpm/psP (lpm/barv) 25.2 (363) Thread Size 1" NPT (25mm BSPT) Sprinkler Orientation Pendent Maximum Working Pressure 175 psi '12 bar PSI (bar) WARNING: Cancer and ReproductWe Harm- zt Page 1 of 7 ESFR PENDENT SjJ II(II,(1G ® SPRINKLER VK5I0 (K25.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendant Sprinkler VK5I0 in- corporates the capability to suppress specific high-challenge fires, The addition of a larger K-Factor allows ESFR performance at lower end-head pressures than ESFR K14 sprinklers. K25.2 ESFR sprinklers can; Eliminate the use of in-rack sprinklers when protecting high-piled storage of certain specified materials up to specific heights,* Reduce or eliminate the need for a system fire pump. Provide flexibility when sizing system piping. Viking VK510 ESFR Pendent Sprinklers are primarily intended to protect the fol- lowing types of storage, which tend to produce severe-challenge fires: palletized and solid pile storage and single, double, multiple row, and portable open rack storage (no open-top containers or solid shelves). Viking ESFR Pendant VK5I0 Sprinklers provide protection of most common stor- age materials, including: Encapsulated or unericapsulated Class I, II, III, and IV commodities*. cULus Listed for protection of cartoned unexpanded plastic commodi- ties and FM Approved for protection of cartoned and uncartoned unex- panded plastic commodities*. FM Approved for protection of exposed expanded polystyrene and ex- posed expanded polyurethane commodities*. In addition, some storage arrangements of rolled paper, flammable liquids, aerosols, and rubber tires may be protected by Viking ESFR Pendant Sprinkler VK5I0. 2. LISTINGS AND APPROVALS 11011, cULus Listed: Category VNWH (Listed as a Specific Application ESFR Sprinkler) <~> FM Approved: Class 2026 nVdS Approved: Certificate G4040015 Lon LPCB Approved: Ref, No. 096g/01 China Approval: Approved according to China GB Standard The 10280 VK5I0, ESFR Pendant Sprinkler Assembly conforms to the provision of CUAPII.03103 standard. CUAPII.03/03 approvals are provided by: FM Approvals Ltd. I Windsor Dials Windsor, Berkshire, UK, SL4 1 RS Approval Certificate No. issued December 20, 2010, Note: Other International approval certificates are available upon request. *Refer the Approval Chart and Commodity Selection and Design Criteria Overview for cULus Listing and FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to NFPA 13 or FM Global Loss Prevention Data Sheets. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1" NPT for Sprinkler 12080, 25 mm BSPT for Sprinkler 12200 Nominal K-factor: 25.2 U.S. (363 metric*) * Metric K-factor measurement shown is In bar. When pressure is measured in kPa, divide the metric K-factor shown by 10,0. Form No. F 100102 20.01.23 Rev 20.1 Replaces Form No F 100102 Rev 19.2 (Revised FM Specification) Page 2 of 7 ESFR PENDENT 4JIF(IIIGii SPRINKLER VK5I0 (K25.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikInggroupinc.com Overall Length: 3-3/16' (81 mm) Deflector Diameter: 1-3/4" (44.5 mm) Covered by one or more of the following patents: US5,829,532; U86,059,044; U$6,336,509; US6,502,643; US6,868,917; AU722593; G82336777 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-CSI 000 Seat: Copper UNS-C11000 and Stainless Steel UNS-S30400 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Compression Screw: Stainless Steel UNS-S31603 Trigger and Support: Stainless Steel UNS-531600 Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint. Ordering Information: (Also refer to the current Viking price list.) Order ESFR Pendent Sprinkler VK5I0 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A Temperature Suffix: 165 "F (74 "C) = C, 205 "F (96 "C) = E For example, Sprinkler VK5I0 with 1" NPT threads, Brass finish, and 165 "F (74 "C) temperature rating = Part No. 12080AC. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Part No. 13635W/B (double-ended wrench - Use Side B. Side A is for use with K14.0 ESFR Pendent Sprinkler VK500) Available since 2006. Sprinkler Cabinet: Six-head capacity: Part No. 01731A (available since 1971) 4. INSTALLATION Sprinklers must be handled with care. They must be stored In a cool, dry place in their original shipping container. Never A WARNING Viking sprinklers are manufactured and tested to meet rigid requirements of the approving agencies. The sprinklers are designed to be installed in accordance with recognized installation standards or FM Global Loss Prevention Data Sheets. System design must be based on ESFR design guidelines described in the latest edition of the applicable FM Global Loss Prevention Data Sheets, the latest NFPA Standards, the latest standards of Verband der Sachversicherer (VdS), Loss Prevention Council (LPCB), the Authorities Having Jurisdiction, and also with the provisions of govern- mental codes, ordinances, and standards whenever applicable. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. install sprinklers that have been dropped or damaged in any way. Such sprinklers should be destroyed immediately. NOTE: Wet pipe systems must be provided with adequate heat. The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. With the sprinkler contained in the plastic protective cap, apply a small amount of pipe-joint compound or tape to the male threads only, while taking care not to allow a build-up of compound in the sprinkler orifice. Use ONLY sprinkler wrench 13635W/B (shown in Figure 1) for installing ESFR Sprinkler VK5I01 With the sprinkler contained in the protective cap, Install the sprinkler onto the piping by applying the sprinkler wrench to the sprinkler wrench flats only, while taking care not to damage the sprinkler operating parts. DO NOT use any other type of wrench, as this could damage the unit. DO NOT use the sprinkler deflector or fusible element to start or thread the sprinkler into a fitting. DO NOT exceed 20-30 ft, lbs. of torque (hand tight plus I to 1-1/2 tuirns with the wrench; over-tightening may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. E. After Installation, the entire sprinkler system must be tested. The test must be conducted to comply with the Installation Standards. Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Immediately replace any damaged units, using the special sprinkler wrench only. Form No. F 100102 20.01.23 Rev 20.1 Page 3 of 7 ESFR PENDENT 'titJ 11(4.1 I#1EI SPRINKLER VK5I0 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com F. After installation and testing and repairing of all leaks, remove the protective caps from the sprinklers. Do NOT use any type of tool to remove the cap. Remove the cap by hand: turn it slightly and pull it off the sprinkler. When removing caps, use care to prevent dislodging or damaging sprinkler fusible element. THE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! S. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and bellevilie spring assembly to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to suppress the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the NFPA standard that describes care and maintenance of sprinkler systems. In addition, the Authorities Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. The sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. The frequency of inspections may vary due to corrosive atmosphere, water supplies, and activity around the device. B. Sprinklers that have been painted or mechanically damaged must be replaced immediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. For Viking ESFR Pendent Sprinklers, refer to the Installation Standards (e.g., NFPA 25) and the Authorities Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Sprinklers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprinklers, use only new sprinklers. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. Remove the system from service, drain all water, and relieve all pressure on the piping. Using the special sprinkler wrench, remove the old sprinkler and install the new unit. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response characteristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. Place the system back in service and secure all valves. Check the replaced sprinklers and repair all leaks. E. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY The Viking Model VK510 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F 100102 20.01.23 Rev 20,1 Page 4 of 7 ESFR PENDENT 4J II(II1G SPRINKLER VK510 (K25.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature 2 Frame Paint Color Ordinary 165 F (74 °C) 100 °F (38 °C) None Intermediate 205 OF (96 °C) 150 OF (65 °C) White Sprinkler Finish: Brass Footnotes l The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 1-9/16" (40 mm) 3-3/16" (81 rnm) 1-58 ;cj ,, , ) Dimensions are 1-3/4" approximate. (45 mm) Figure 2: ESFR Pendent Sprinkler VK5I0 Dimensions Form No. F_100102 20.01.23 Rev20.1 Page 5 of 7 ESFR PENDENT \jIKJIP416j® ls:ul[u.7M SPRINKLER VK510 (K25.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupInc.com Approval Chart Temperature KEY ESFR Pendent Sprinkler VK5I0 VI Finish Maximum 175 PSI (12 bar) WWP Al X,*- Escutcheon (if applicable) Nominal Overall Length Listings and Approvals'7 Base Part 'i" Yk Thread K-Factor (Refer also to Tables 2 & 3.) Number' China U.S. metrIc2 Inches mm cULus5 NYC VdS LPCB FM Appral 12080 VK510 1' NPT 25.2 363 3-3/16 81 Al See Footnote 6. Al Al Al -- 12200 VK510 25 mm BSPT 25,2 1 363 3-3/16 81 Al See Footnote 6. Al Al Al -- 203738 VK5I0 125 mm BSPTJ 25.2 1 363 1 3-3/16 81 BI - -- -- B1 Bi Approved Temperature Ratings Approved Finish A- 165 8F (74 °C) and 205 6F (96 C) B-165°F(74QC) 1-Brass Footnotes 1 Base part number shown. For complete part number, refer to the price list. 2 Metric K-Factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-Factor shown by 10.0. This chart shows listings and approvals available at the time of printing. Other approvals may be in process. Refer to the latest standards of NFPA 13, FM Global Loss Prevention Data Sheets, LPCB Loss Prevention Standards, and the latest VdS standards. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada as a Specific Application ESFR Sprinkler (refer to the deflector position requirements on page 7). 6 Meets New York City requirements, effective July 1, 2008. FM Approved as a quick response pendent Non-Storage sprinkler and also FM Approved as a quick response pendent Storage sprinkler. Refer to Tables 2 & 3. 8 Approved according to China GB Standard. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global Loss Prevention Data Sheets including 2-0 and 8-9, VdS, LPCB, and any other Authorities Having Jurisdiction, and also with provi- sions of governmental codes, ordinances, and standards whenever applicable. Form No. F 100102 20.01.23 Rev 20.1 Page 6 of 7 ESFR PENDENT N411UNG I SPRINKLER VK5I0 The Viking Corporation, 210 N industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking wobsite for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 2 COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR MODEL VK510 ESFR PENDENT SPRINKLERS Storage Type NFPA FM Sprinkler Type ESFR Storage Response Type ESFR QR System Type Wet Pipe system only Wet Pipe system only Temperature Rating(s) OF (°C) 165 OF (74 °C) and 205 (96 °C) 165 OF (74 °C) and 205 (96 °C) Open Frame Single, Double, Multiple- Row, or Portable Rack Storage of Class l-IV Refer to NFPA 13. Refer to FM 2-0 and 8-9. and Group A or B Plastics Solid Pile or Pelletized Storage of Class -IV and Group A or B Plastics Refer to NFPA 13. Refer to FM 2-0 and 8-9. Idle Pallet Storage Refer to NFPA 13. Refer to FM 2-0, 8-9, and 8-24. Rubber lire Storage Refer to NFPA 13, Refer to FM 2-0 and 8-3. Rolled Paper Storage (Refer to the standard.) Refer to NFPA 13. Refer to FM 8-21. Flammable Liquid Storage (Refer to the standard.) Refer to NFPA 30. Refer to FM 7-29 Aerosol Storage (Refer to the standard.) Refer to NFPA 30B Refer to FM 7-31 Automotive Components in Portable Racks Refer to NFPA 13. N/A (Control mode only, refer to the standard.) IMPORTANT: Always refer to Bulletin Form No. F091699 - Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be installed in accordance with the latest_ edition of Viking technical data, the latest standards of NFPA, FM Global, VdS, LPCB, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and standards whenever applicable. Form No. F 100102 20.01.23 Rev 20.1 Page 7 of 7 ESFR PENDENT 'sI II(IIs1 I® l:IIrui7. SPRINKLER VK5I0 (K25.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877.384.5464 Fax: 269.818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlkinggroupinc.com TABLE 3: COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR MODEL VK510 SPECIFIC APPLICATION LISTING (UL) AND ESFR, QUICK RESPONSE STORAGE, AND QUICK RESPONSE NON-STORAGE APPROVALS (FM) Description Specification, UL Specification, FM Sprinkler Type ESFR OR Storage Temperature Rating 165 OF (74 °C) and 205 (96 °C) 165 °F (74 °C) and 205 (96 °C) Response Type ESFR OR Sprinkler Position p Pendent, frame arms aligned with pipe, deflectors Pendent, frame arms aligned with pipe, deflectors parallel with ceiling or roof parallel to floor. System Type Wet Pipe System only Wet Pipe System only Maximum Area of Coverage 100 ft2 (9.3 m2) 100 ft, Refer to FM 2-0, Table 17 Minimum Area of Coverage 64 f12 64 (5.9 m2) ft' (5.9 m2)2 Refer to FM 2-0, Table 17 Maximum Ceiling Slope 2 In 12 Up to loo Refer to FM 2-0, Section 2.2.1.6 Upto30ft.: 12 ft, (3.7m) Maximum Spacing 10 ft. spacing (3.0 m) For building over 30 ft.: 10 ft. (3.0 m) Refer to FM 8-9, Section 2.3.3.3 Minimum Spacing 8 ft. spacing (2.4 m) Refer to FM 8-9, Section 2.3.3.3 Deflector Distance from Minimum of 4 in. (102 mm) from wails but no more than Refer to FM 2-0, Section 2.2.3.3 Walls 1/2 the allowable distance permitted between sprinklers Minimum of 36 inches (914 mm) Deflector to Top of Storage Minimum of 36 in. (914 mm) Refer to FM 2-0 Section 2,2.2.1 and FM 8-9, Section 2.2.6 Ceiling/roof heights up to 40 ft. (12.2 m): Deflector** to Ceiling 6-18 in. (152-457 mm) Refer to FM 2-0 Distance Ceiling/roof heights of 40-45 ft. (12.2-13.7 m): 6-14 in. (152-356 mm) Maximum Ceiling Height 45 ft. (13.7 m) 50 ft, (15.2 m) Maximum Storage Height 40 ft. (12.2 m) 45 ft. (13.7 m) Storage Arrangement Pelletized, solid piled, open frame; single row, double Refer to FM 8-9, Tables 2 through 11 row, or multiple row and portable rack arrangement Commodity Class l-IV, Cartoned unexpanded plastic Refer to FM 8-1 and 8-9 NFPA 13 for ESFR Sprinklers based upon 40 psi Sprinkler System Design (2.8 bar) design pressure 159.4 gpm (603.4 1pm) with 12 Refer to FM 8-9, Tables 2 through 11 sprinkler remote area Obstruction Criteria Refer to NFPA 13 Chapter 8. Refer to FM 2-0 Section 2.2 Minimum Aisle Width 3 ft.-6 In. (1.07 m) Over 2 ft. (.61 rn) Hose Stream Allowance and 250 gpm (946 1pm) for 60 minutes or as determined by 250 gpm (946 1pm) for 60 minutes or as determined by Water Supply Duration the approval the approval * The maximum coverage area must not exceed 100 ft2. ** For FM, the measurement is from the centerline of the thermal sensing element to the coiling. Form No. F100IO2 20.01.23 Rev 20.1 Replaces Form No F 100102 Rev 19.2 (Revised FM Specification) NOTE. As of May 20I0 all togoc have been removed from the wvsnch bass, WARNING: Cancer and Reproduceve I-term www.P65Warnings.cagov Page 1 of 5 STANDARD RESPONSE 'ij IIJ 4 ELO UPRIGHT SPRINKLER (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N industrial Park Drive, Hastings MI 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION The Viking Standard Response ELO Upright Sprinkler VK530 is a thermosensitive glass bulb spray sprinkler available In several different finishes and temperature ratings to meet design requirements. The special Polyester, PTFE, and Electroloss Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for Installation in corrosive environments and are listed/approved as indicated in the Approval Charts. The extra-large orifice provides greater flows at lower pressures than standard orifice or large orifice sprinklers. This feature allows reduced pipe sizing for hydraulically calculated sprinkler systems, which require high densities of water. Viking Standard Response Extra-Large Orifice Sprinklers may eliminate the need for a fire pump or reduce the size of the pump if it is required. On existing systems, replacing large orifice sprinklers with extra-large orifice sprinklers may provide the higher densities required to allow an increase in the hazard classifica- tion of an occupancy. Viking standard response sprinklers may be ordered and/or used as open sprin- klers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions below. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2009 Refer to Approval Chart 1 and Design Criteria on page 3 for cULus Listing require- ments, and refer to Approval Chart 2 and Design Criteria on page 4 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1992. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" NPT or 20 mm BSP Nominal K-Factor: 11.2 U.S. (161.3 metric*) *Metric K-factor measurement shown Is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-5/16" (58.7 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 5 mm diameter Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-S30400 Compression Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated Form No. F_010692 19.10.14 Rev 19.1 Replaces Form No. F010692 Rev 18.2.P65 (Added ENT; updated FM language.) Page 2 of 5 ,,144 1 STANDARD RESPONSE IK ELO UPRIGHT SPRINKLER VK530 (STORAG E-D ENS ITYIAREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877.384.5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Extra-Large Orifice Upright Sprinkler VK530 by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number, Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, Wax Coated C, ENT =JN Temperature Suffix ('IFrC): 155°/68° = B, 175/79 = D, 200I93° = E. G, OPEN = Z (PTFE only). For example, sprinkler VK530 with a Brass finish and a 155 °F/68 C temperature rating = Part No. 09679AB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 05118CW/B (available since 1981). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Standard Response Extra-Large Orifice Upright Sprinkler VK530 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No, F_010692 19.10.14 Rev 19,11 Page 3 of 5 STANDARD RESPONSE ELO UPRIGHT SPRINKLER 'JII(II4IG VK530 (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal I Maximum Ambient I Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 155°F(68°C) 100 °F(38°C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135°F (570C). Wax-Coated Brass for sprinklers with the following temperature ratings: 155 OF (68 °C) Lt. Brown Wax 175 OF (79 °C) Brown Wax 200 OF (93 °C) Brown Wax 286 OF (141 °C) Dk. Brown Wax4 Footnotes ¶ The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific Installation standards. The corrosion-resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts, These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For PTFE coated open sprinklers only, the waterway is coated, For all ENT coated sprinklers, the waterway is coated. 1 Wax melting point is 170 OF (76 °C) for 286 OF (141 °C) temperature rated sprinklers. Protective clip Wrench flat IMOS118CWIB Figure 1: Sprinkler VK530 and Wrench 1-3/4" (45 mm) 2.5/16" 1. (59 mm) 3/4" NPT (20 mm) Figure 2: Sprinkler VK530 Dimensions Form No. F 010692 19.10.14 Rev 191 Page 4 of 5 STANDARD RESPONSE \I Ila I1G® ELO UPRIGHT SPRINKLER VK530 (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart I (UL) Temperature KEY Standard Response Extra-Large Orifice Upright Sprinkler VK530 Rsh Maximum 175 PSI (12 Bar) WWP AIX 4— Escuttheo n (t applicabe} Base Part Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' Number SIN Style (Refer also to Design Criteria below.) NPT BSP U.S. motric Inches mm cULus4 NYC 09679 VK530 Upright 3/4" -- 11,2 161,3 2-5/16 58.7 A3, BI, C2, B4 See Footnete8. 14819 VK530 Upright - 20mm 11,2 161,3 2-5/16 58.7 A3, B1, C2, B4 -- Approved Temperature Ratings Approved Finishes A - 286 "F (141 "C) I - Brass, Chrome, White Polyester5, Black Polyester', and Black PTFE B - 155 "F (68 "C), 175 "F (79 "C), 200 "F 2 - Wax-Coated Brass (corrosion resistant) (93 "C). and 286 "F (141 "C) 3 - Brass with 200 "F (93 "C) Wax Coating (corrosion resistant); Maximum ambient ceiling temperature 150 C - 155 "F (68 "C), 175 "F (79 "C), and "F (65 "C). 200 "F (93 "C) 4 - ENT' Footnotes l Base part number shown, For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion-resistant. Meets New York City requirements, effective July 1 2008, DESIGN CRITERIA - _UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: Standard Response Extra-Large Orifice Upright Sprinkler VK530 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard spray upright sprinklers: Designed for use in hazard occupancies up to and including Extra-Hazard Group II with a minimum operating pressure of 7 psi (0.5 bar). Sprinkler VK530 is also cULus Listed for use in High-Piled Storage Occupancies as defined in NFPA 13 with a minimum operating pressure of 7 psi (0.5 bar). The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray upright sprinklers must be followed, IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. - Form No. F_010692 19.10.14 Rev 19,1 Page 5 of 5 IV I jU WS STANDARD RESPONSE 4 ELO UPRIGHT SPRINKLER VK530 (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone; 269-945.9501 Technical Services: 877-384.5464 Fax; 269418.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart 2 (FM) Temperature KEY Standard Response Extra-Large Orifice Upright Sprinkler VK530 Firrish Maximum 175 PSI (12 Bar) WWP Al 4- Escutcheon (f appticabte) Base Part SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length FM Approvals Number' - - - NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 09679 VK530 Upright 3/4' -- 11.2 161.3 2-5/16 58.7 Al, A2 14819 VK530 Upright 20 mm 11.2 16113 2-5/16 587 Al, A2 Approved Temperature Ratings Approved Finishes A - 155 ¶ (68 SC), 175 °F (79 5C), 200 °F (93 °C), and 286 °F 1 ; Brass and Chrome (141 C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Other approvals may be In process. FM Approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Standard Response Extra-Large Orifice Upright Sprinkler VK530 is FM Approved as a standard response upright Non-Storage sprinkler, and as a standard response upright Storage sprinkler as indicated in the FM Approval Guide, For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No, F_010692 19.10.14 Rev 19.1 Replaces Form No. F010692 Rev 18.2.P65 (Added ENT; updated FM language) FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe IId) ] AD) iFtimbag L& 4010 my wwop I kow—o-) §W 1 1.315 1.097 1.41 lbs/ft 91 11/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 2 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe L - ( I I L 1 1.315 1.049 1.68 lbs/ft 70 11/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.260 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q!WD 1819 Clarkson Road For additional information, Chesterfield, MO 63017 contact your salesperson C@U3 MOOSE TUBE COMNV (800) 325-4467 today at (800) 325-4467 or mm A FAX: (636) 537-2645 (636) 537-2600 in the USA, www.buflmoosetube.com or from Canada Ae> ACfiEflB company e-mail: sa1esbu11inoosetube.com call (800) 882-4666 Appov'D All information contsnsd herein Ir, accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications with* notice and without Incurring obligation. 8/013 NO. 20 TEE NO. 10 ELBOW ALTERNATE STYLES Victaulic offers a broad line of fittings in sizes through 60/1500mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange® adapters, check disc clearance dimensions with I.D. dimension of fitting. Note: The following Victaulic fittings are VdS approved: No.10 90" Elbow, No.11 45" Elbow, No.20 Tee and No.60 Cap. Note: The following Victaulic fittings are LPCB approved: No.10 90" Elbow, No.11 45" Elbow, No. 12 22 ½" Elbow, No.13 111%" Elbow, No.30 45" Lateral, No.30-R Reducing Lateral, No. 100 Long Radius Elbow, No. 110 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee, No.33 True Wye, No.50 Concentric Reducer, No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Advanced Groove System - For 14— 60'/350 - 1500 mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8/25 - 200mm, Refer to Section 21.03 or contact Victaulic for details. Fabricated Steel - A full range of fabricated segemtnally welded steel or full flow grooved end fittings are available refer to section 07.04. Fabricated Steel with AGS Vic-Rings - A full range of full flow fabricated fittings with Vic-Rings are also available. AGS - ADVANCED GROOVE SYSTEM Extra Heavy EndSeal® "ES" Fittings - EndSeal fittings are available in 2— 12/50 — 300 mm for use with "ES" grooved pipe and HP-70ES EndSeal couplings. "ES" fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) - For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. Note: Fittings are available with a variety of coatings upon request such as hot dip galvanized, epoxy, glass lined and others. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV R \4taulic 0z01-1 CARBON STEEL PIPE GROOVED FITTINGS 07.01 Grooved End Fittings MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) 3/4 - 4720— 100 mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F 5-6/125 - 150mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type E or S, Gr. B 8— 12/200 - 300mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type Ear 5, Gr. B Flanged Adapter Nipples: (Nipple - see above) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com ictaulid vICTAULIC IS A REGISTERED TRADEMARK OF vtcrAuLic COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07,012 CARBON STEEL PIPE GROOVED FITTINGS 07.01 Grooved End Fittings FLOW DATA The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight (rir h.rrtI P tctnr ) pipe. Fittings not listed can be estimated from the data given, for example, a 221/2 elbow is pproximateiy one-nail me resistance oi a 40 eiDow. Values 01 mid-sizes can De interpolated. Size •1mrnnc.i.nwn,cis Till lfths1J I 41dI8Es ' ¶ t1iIfi . tZ Li' 1j I -- 8s4rw Ier gm 1 1.315 1.7 0.8 4.2 1.7 25 33.7 2.375 0.5 3.5 - - 2.5 0.2 1.8 - 1.1 13 8.5 0.5 3.5 2 50 60.3 3.000 1.1 4.3 0.8 0.5 2.1 0.3 2.6 10.8 1.1 4.3 761 mm 76.1 3.500 1.3 5.0 - 3.8 0.7 2.6 - 1.6 3.3 13.0 1.3 5.0 3 80 889 4.250 1.5 6.4 1.2 0.8 3.2 0.5 40 15.3 1.5 6.4 1080 mm 108.0 4.500 2.0 6.8 - 5.0 0.9 3.4 - - 2.1 4.7 16.0 2.0 6.8 4 100 114.3 5.250 2.1 8.1 1.5 1.0 4.1 0.6 4.9 20.0 2.1 8.1 1330 mm 133.0 5.500 2.5 8.5 - 1.2 4.2 - 6.2 21.0 2.5 8.5 1397 mm 139.7 5.563 2.6 8.5 - 1.3 4.2 - - 6.4 21.0 2.6 8.5 5 125 141.3 6.250 2.6 9.4 - - 1.3 4.9 - - 6.4 25.0 2.6 9.6 1590 mm 159.0 6.500 2.9 9.6 - 1.5 5.0 - 7.6 25.0 2.9 10.0 165.1 mm 165.1 6.625 2.9 10.0 - 7.5 - 1.5 5.0 - 3.0 7.6 25.0 3.0 10.0 6 150 168.3 8,625 - 3.0 13.0 2.3 9.8 1.5 6.5 0.9 - 4.0 7.6 33.0 3.0 13.0 8 200 219.1 - 10.750 4.0 17.0 3.0 12.0 - 2.0 8.3 1.2 5.0 10.1 41.0 4.0 17.0 10 250 273.0 12.750 5.2 20.0 3.7 14.5 2.5 10.0 1.5 - 6.0 12.5 50.0 5.2 - 20.0 12 300 323.9 14.000 6.1 24.56 4.4 15.8 3.0 18.5 § 1.8 11.0 15.2 70.0 61 23.0 14 350 355.6 16.000 7.5 28.06 4.8 , - 18.0 5.6 21.08 3.4 13.0 - 21.3 80.0 7.0, 27.0 16 400 406.4 ' 18.000 , 8.5 31.08 5.5 - 20.0 6.4 23.56 4,0 14,0 24.4 - - 90.0 8.2 30 18 450 457.0 20.000 9.5 - 3405 6.1 22.5 - 7.2 25.55 4.3 - 16.0 27.4 100.0 9.1 33.0 20 800 508.0 24.000 , 10.4 42.06 6.9 - 27.0 - 7.8 29.5 § 4.9 19.0 - 30.5 120.0 10.1 40.0 24 600 610.0 - - 12.8 - 8.2 - 9.0 5.8 36.6 , 12.2 Fittings available up to 6071500 mm. Contact Victaulic for details. S Contact Victaulic for details. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Fitting flow data for 14-24/350-600 mm size No, 10 and No. ii Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings (No. Wi 0 and No. Wi 1 Elbows), refer to submittal 20.05. Note: All fittings are ductile iron unless otherwise noted with an "sw or "s'. S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded www.victaulic.Com jttauIIc )t( vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV -R 07,013 CARBON STEEL PIPE GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee bctoE -CtoE.1 CtOEj NO. 25 Grooved Branch NO. .291 Threaded Branch to Lj_Ito to to C C NO. 25 25 NO. 29T NO. 25-SW NO. 29T-SW 8W . (Alto I 8r4.b 14tb 51111 I51 3I1571 . 1 1 3/~ 2.255w 2.24sw 1.0 4 4 1¼ 5.00sw 5.00sw 9.6 25 20 57 2.75 Sw 57 2.75sw 0.5 1.3 100 100 32 1½ 127 127 4.4 5.00 - 5.00 10.2 11/4 1¼ 1 x 32 32 25 70 2.75sw 70 2,75sw 0.6 1.5 40 2 127 127 4,6 5.00 5.00 11.2 1½ 11/s ~ 40 40 20 70 70 0.7 50 127 127 5.1 1 2.75sw 2.75sw - 1.5 21/2 5.00 5.00 11.4 25 , 70 70 0.7 65 127 127 5.2 1¼ 2.75sw 2.75sw 1.7 3 5.00 5.00 * 11.6 32 70 3.25 70 3.25 0.8 2.5 80 127 127 5.3 5.50sw 5.50sw 14.0 2 2 3/4 x 5 5 1 50 50 ><20 83 83 - 1.1 125 >< 125 x 25 140 140 6.4 , 1 3.25 3.25 2.7 1½ 5.50sw 5.50sw 14.3 25 . 83 83 1.2 , 40 140 140 6.5 , 1¼ 3.25sw 3.255w ' 1.8 2 5.505w 5.505w 14.5 32 83 83 0.8 50 140 140 6.6 1½ - 3.25 3.25sw 3.0 2½ 5.50 - 5.50sw 15.2 40 83 3.75sw 83 3.75sw 1.4 3.9 65 3 140 140 6.9 5.50 5.50sw 16.6 21/2 2½ '/4 x 65 65 x 20 95 95 1.8 80 140 140 7.5 - 3.75 3.75sw 38 4 5.50 5.50sw 16.7 25 95 95 1.7 100 140 140 7.6 6 6 1 x x 1¼ 3.75sw 3,75sw 4.2 6.50sw 6.50sw 23.0 32 95 95 1.7 150 150 25 165 165 10.4 1½ 3.75 3.75 - 3.9 1½ 6.50sw 6.50sw 24.0 40 95 95 1.8 40 165 165 10.9 2 3.75 3.755w 4.5 - - 2 6.50 6.50 21.6 50 95 , 95 4.255w - 2.0 5.7 50 2½ 165 165 9.8 6.50 6.50 21.4 3 3 3/4 4.25sw 80 >< 80 20 108 108 2.6 65 165 165 11.7 - 25 108 108 28 350-1500mm -For AGOAGS fitting information, see publication 20.05 1¼ 4.25sw 4.25 Sw 8.0 + Contact Victaulic for details. 32 108 108 3.6 Note: All fittings are ductile iron unless otherwise noted with an 'sw' or "s' 1½ 4.25 4.25sw 6.5 40 108 108 2.9 S= Carbon Steel Direct Roll Groove (OGS) 2 - 4.25 4.25sw - 6.2 - SW= Carbon Steel Segmentally Welded 50 108 108 2.8 IMPORTANT NOTE: 2½ - 425 425sw - 64 65 108 5.00sw 108 5.00 SW 29 80 No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly 4 4 3/4 x 100 100 >< 20 127 127 - 3.6 on order. 1 5.00 5.00 7.8 25 127 127 3.5 www.victaulic.com 14 ictauha VICTAIJLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2012 VICTAULIc COMPANY. ALL RIGHTS RESERVED. J_~_c 07.01 10 REV R CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee CtoE .-CtoE.1 4-CtoE-o -CtoE.1 NO. 25 Grooved Branch ---[FI- to to ft_J --- 1 --=a NO. 29T Threaded Branch to NO. 25 NO. 291 NO. 25-SW NO. 29T-SW r -o8s 6 6 3 6.50 6.50 150 < 150 80 165 165 6.50 - 6.50 100 165 165 6.50 6.50 125 165 6.50 165 6.50sw 61/2 61/2 3 x 165.1 165,1 5< 80 165 165 4 6.50 6,50sw 100 165 ' 7.755w - 165 7.75sw 8 8 1½ 200 x 200 >< 40 197 197 2 7.755w 7.755w 50 197 197 - 21/2 7,755w 7.75sw 65 197 197 3 7.755w 7,755w 80 197 197 4 7.75 7.75 100 197 197 , 5 7.75 5w 7.75sw 125 197 197 7.75 . 7.75 150 197 197 , 65.1 7755w 7.75sw 197 9.00 , 197 9.00 10 10 1½ 250 5< 250 5< 40 229 - 229 2 9.00sw 9.005w 50 229 229 2½ 9.005w 9.00sw 65 229 229 3 9.005w 9.00sw 80 229 229 4 9.00sw 9.00sw 100 229 229 , 5 ' 9.00sw 9.00sw 125 229 229 6 9.00 Sw 9.00 Sw 150 229 229 9.005w 9.005w 200 229 229 26.5 12 12 1 10.00sw 10.00sw 77.0 x x 12.0 300 300 25 254 254 34.9 25.0 2 10.005w - 10.00sw 80.0 11.3 50 254 254 36.3 23.2 21/2 10.00sw ' 10.005w 78.0 10.5 65 254 254 35.4 24.0 3 10.005w 10.00sw - 82.0 10.9 80 254 254 37.2 25.0 4 10.00sw ' 10.005w 80.0 11.3 100 254 254 36.3 33.0 5 ' 10.00sw - 10.005w - 75.0 15.0 125 254 254 34.0 33.5 6 10.005w - 10.005w 75.0 15.2 150 254 254 34.0 39.0 8 10.005w - 10.005w - 80.0 17.7 200 254 254 36.3 , 33.6 10 10.00sw 10.005w 84.0 15.2 250 254 254 38.1 41.8 #14 14 4 ' 11.005w 11.00sw 102.0 19.0 350 x 350 X 100 279 279 46.3 34.0 6 11.00sw - 11.005w - 108.2 15.4 150 279 279 49.1 42.3 8 11.00 1100 112.0 19.2 200 279 279 50.8 48.0 10 11.00 11.00 120.0 21.8 300 279 279 54.4 62.0 12 ' 11.00 11.00 - 129.1 28.1 300 279 279 58.6 - 62.0 - #16 16 4 130.0 28.1 - 400 x 400 X 100 + + 59.0 624 14- 60 1 28.3 , AGS For AGS fitting information, see publication 20.05 350-1500mm 60.0 + Contact Victaulic for details. 27.2 Note: All fittings are ductile iron unless otherwise noted with an "ow" or "s" - 61.0 27.7 S= Carbon Steel Direct Roll Groove (OGS) 52.0 SW= Carbon Steel Segmentally Welded 236 IMPORTANT NOTE: 590 26.8 No. 291 Threaded Outlet Reducing Tees are supplied NPT and are available 64.7 with British Standard threads. For British Standard specify "BSP" clearly 29.3 on order. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office, www.victaulic.com \J'tauIIc' vlclAuLlc IS A REGISTERED TRADEMARK OF VICTAIILIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVJ 07,0111 CARBON STEEL PIPE GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee CtoE1 - CtoE NO. 25 Grooved Branch NO. 29T Threaded Branch to jJJ NO. 25 NO. 29T iflI . IiJ thx1a Ijis4v 16r4k; Yeff I1 . 311111 .1 #16 x 16 6 12.005w 12.00sw 133.5 920 20 16 17.25 288.6 400 400 150 305 305 60.6 500 X 500 400 438 - 130.9 12.00 12.00 145.0 18 17.25 297.0 200 305 305 65.8 450 438 - 134.7 #24 24 8 x - 10 12.00 12.00 149.5 2000 2000 3400 250 305 305 - 67.8 600 oo 200 508 508 154.2 12 12.00 12.00 154.0 10 20.00 20.00 343.9 300 305 305 69.9 250 508 508 156.0 14 12.00sw 167.0 12 20.00 20.00 352.8 350 305 - 75.8 300 508 508 160.0 8 18 18 4 15,50sw 15.50sw 194.0 145 20.00 360.0 x 450 450 x 100 394 394 88.0 350 - 508 163.3 6 15.50sw 15.50sw 200.0 16 20.00 378.0 150 394 394 90.7 400 508 - 171.5 8 15.50sw 15.50sw 202.0 188 20.00 380.0 200 394 394 91 .6 450 508 - 172.4 10 15.50 15.50 212.0 20 20.00 373.0 250 394 394 96.2 500 508 - 169.2 12 15.50 15.50 222.6 14 - 60" AGS-For AGS fitting information, see publication 20.05 300 394 394 101.0 350- 1500mm 14 15.50 230.1 + Contact Victaulic for details. 350 394 - 104.4 - - -+ - Note: All fittings are ductile iron unless otherwise noted with an "sw' or "s' 16 15.50 247.6 400 394 - 112.3 S= Carbon Steel Direct Roll Groove (OGS) #20 20 6 17.25 17.25 240.0 SW= Carbon Steel Segmentally Welded 500 >< 500 x 150 438 438 108.9 - - - -, IMPORTANT NOTE: 8 17.25 17.25 244.0 200 438 438 110.7 - - No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available 10 17.25 17.25 256.0 with British Standard threads. For British Standard specify "BSP" clearly 250 438 438 116.1 on order. 12 17.25 17.25 264.0 8 For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). 300 438 438 • 119.8 For pricing and availability of cut groove fittings in this size, contact your 147 17.25 275.0 nearest Victaulic sales office. 350 438 - 124,7 § Cast fitting available. Contact Victaulic for details. www.victaulic.com \./tauI jc0 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. i 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 070112 REVR INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 08/2012 07.01 1449 REV R ictaulic vIcTAULIc IS REGISTERED TRADEMARK OF \IICTAuLIC COMPANY. Q 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01 FireLock EV Rigid Coupling STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe I1,1a11 tz 3j4; g 1¼ 175 365 365 365 365 32 - 1206 2517 2517 2517 2517 1½ 175 365 365 365 365 40 1206 2517 2517 2517 2517 2 175 365 365 - 365 • 365 50 1206 2517 2517 2517 2517 2½ N/A 365 365 365 365 65 2517 - 2517 2517 2517 76.1 mm N/A N/A 365 365 365 2517 2517 2517 - N/A 365 365 365 365 80 - 2517 2517 - 2517 2517 - 108 mm N/A 365 365 N/A N/A 2517***_2517 N/A • 365 365 - 365 - 365 100 2517 2517 2517 2517 - 290w 365" 133 mm N/A N 1999"' 2517" /A N/A - 139.7 mm N/A N/A 290 232 365 1999 1600 2517 165.1 mm N/A N/A 290 232 365 1999 1600 2517 - 6# - - N/A - 290 365 232 365 150# 1999 2517 1600 2517 * Listed/Approved for wet and dry pipe systems (> -40°F/-40°C). Please refer to the Victaulic Installation Manual (1-009H_009_009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) P Regional availability only# FM Approved only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV G \,,tauI1c 10,611 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ Rigid Coupling STYLE 009H LISTINGS/APPROVALS * Speciality Pipe BLT 1¼-2 300 300 EZT 11/4-2 300 300 MT 1 /4 - 2 300 300 - 1¼-4 2068 300 300 FF 2068 2068 1¼-4 300 2068 300 1 ¼ - 2 2068 N/A 2068 - 300 OF MLT 1¼-2 2068 300 2068 300 1¼-4 2068 N/A 2068 300 11/4- 2 -300 N/A 2068 DT FLF ST 1¼-4 2068 175 2068 175 FLT 1¼-2 N/A 2068 300 1¼-4 N/A 2068 300 - EF SIF 1¼-2 1206 300 1206 300 1¼-2 N/A 300 2068 2¼-4 N/A 2068 300 EL TE TF 1¼-2 2068 300 2068 300 1 1/4 - - 2 300 300 2068 11/4 -2 WLS 300 300 - 6140 3-4 MF 2068 300 2068 300 1¼-4 2068 300 300 2068 2068 1¼-2 N/A 2068 175 EZF WST 2068 2068 2068 2068 1/4-2 300 1206 300 XL 2068 2068 sizes. Note: The Specialty Pipe table only applies to imperial sizes, NOT to metric www.victaulic.com \Jtaukc vIcTAuLIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2012 vICTAuLIc COMPANY. ALL RIGHTS RESERVED. 10,61 2 REV G IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZO Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS 1111111110 Rob ____ ix L2i iffl 7F . .i 1¼ 1.660 365 790 0.10 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1.4 32 42.4 2517 3514 2.54 -M10x2 75 121 69 118 49 0.7 11/2 1.900 365 1035 0.10 2 - 3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 - M10 x 2 81 126 75 122 49 0.7 STYLE 009H PRE-ASSEMBLED 2 2.37 5 365 1616 0.12 2 - 3/8 x 2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 3.05 - MID x 2 96 140 88 138 49 0.9 21/2 2.875 365 2370 0.12 2 - 3/8 x 21/2 4.29 6.09 3.92 5.85 1.93 2.1 65 73.0 2517 10542 3.05 -M10x2 1h 109 155 100 149 49 1.0 76.1 mm 76.1 2517 11476 3.05 -M10x2½ 112 160 103 150 49 1.0 3.000 365 2580 0.12 2 - 3/8 x 2 ½ 4.40 6.31 4.05 5.90 1.93 2.1 3 3.500 365 3512 0.12 2 - 3/8 x 21/2 4.91 6.70 4,55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 -M10x21/2 125 170 116 164 49 1.0 108 mm 4.250 365 5178 0.17 2 - 3/8 x 2 1/2 5.56 7.61 5.27 7.51 2.14 2.8 108.0 2517 23030 4.32 - MIO x 2½ 141 193 134 191 54 1.2 STYLE 009H JOINT ASSEMBLED 4 4.500 365 5805 0.17 2 - 3/8 x 21/2 5.95 • 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 - MIO x 2½ 151 199 141 190 55 1.3 133 mm 5.250 365 7900 0.17 2 - 3/8x 2 1/2 6.66 9.11 6.36 9.01 2.14 4.3 133.0 2517 35140 4.33 - MIO x 2 1/2 169 232 162 229 55 1.9 - 5.500 365 • 8620 0.17 2 -3/8x2 1/2 6.75 9.29 6.46 9.23 2.09 4.6 139.7mm 139.7 2517 38340 4.32 -M10x21/2 172 236 164 234 53 2.1 1651 mm 6.500 290 9623 0.17 2 - 5/8 x 3¼ 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 -M16x31/4 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 2 - 5/8 x 3 1/4 7.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 - M16 x 3 1/4 202 281 195 305 54 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown in the chart on page 1, specific to pipe schedule and size. The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America, Asia Pacific) Red enamel (Europe) Optional Coatings: Hot dipped galvanized Gasket: Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com - VIcTAULIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. taul.0 REV..G 10.61.. 3 STYLE 009H GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps con- taining the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade "E" Type A gaskets. These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.61 5731 REV 0 UPDATED 09/2012 Ai—c—telulid VICTAULIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10,61 Victaulic® Flexible Coupling 4tauC Style 75 ii 06.05 Exaggerated for clarity Approvals/Listings 0@'LLPCBl® € See Victaulic publication 10.01 for details See Victaulic publication 02.06 for portable water approvals if applicable. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "1" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "1" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. A WARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and I the designation RX on the front of the roll sets. Job/Owner Engineer System No. Location Contractor Submitted By Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 updated 09/2014 © 2014 Victaulic Company. All rights reserved. 1 ictaul,c victaulic.com I Couplings I Flexible I Style 75 1 Publication 06.05 Material Specifications Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) O Standard: Orange enamel. o Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE: Additional gasket styles are available. Contact Victaulic for details. 0 Grade "E" EPOM EPDM (Green stripe color code). Temperature range —30"F to +230"F/-34"C to +110"C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73"F/+23"C and hot +180"F/+82"C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. O Grade "1" Nitrile Nitrile (Orange stripe color code). Temperature range 20"F to +180"F/29"C to +82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150"F/+66"C or for hot dry air over +140"F/+60"C. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 ___________ victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation Centerline Bolt/Nut4 X V Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm kPa N mm Degrees mm/rn (No.) size inches mm mm mm kg 1 1.315 500 680 0-0.06 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 2-43' 48 2-3/ax2 61 108 45 0.6 1 1/4 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2 - 10' 38 2-3/a x2 68 117 45 0.6 1 1/2 1.900 500 1420 0-0.06 0.40 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 1 - 56' 33 2-3/8x2 74 122 45 0.6 2 2.375 500 2215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1 - 31' 26 2-3/8 x2 87 133 48 0.8 2 1/2 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1 -15' 22 2-3/8x2 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 - 1 12' 0.26 2-3/8x2 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4800 0-0.06 0.22 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 1 -2' 18 2-½x2~ 114 178 48 1.3 31/2 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0-54' 16 2-½x2~ 127 191 48 1.3 4 4.500 500 7950 0-0.13 0.34 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 1 - 36' 28 2-½X23/4 147 204 54 1.9 108.0 mm 4.250 450 6380 0-0.13 - 1 41' 0.35 2-12x70 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 41/2 5.000 450 8820 0-0.13 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1 -26' 21 2-5/8 x3'/4 156 240 54 2.5 5 5.563 450 10935 0-0.13 0.27 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 1 -18' 23 2-5/sx3¼ 175 256 54 2.6 133.0 mm 5.250 450 9735 0-0.13 - 1 21' 0.28 2-16x82.5 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 24 166 238 54 2.7 139.7 mm 5.500 450 10665 0-0.13 1 -18' 0.28 2-%x3¼ 6.80 9.59 2.13 6.3 139.7 3100 47460 0-3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12735 0-0.13 - 1 12' 0.21 2-5/8x3¼ 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15525 0-0.13 0.23 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 1 - 18 2-5/8X3'/4 203 281 54 3.2 159.0mm 6.250 450 13800 0-0.13 - 1 9' 0.24 2-16x82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3.2 20 194 266 54 3.1 8 8.625 450 26280 0-0.13 0.18 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 0-50' 14 2-3Ax4¼ 263 355 59 5.6 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 1/4-3 ½"I20-90 mm; 25% for 4'/lOO mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 JtauIic victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are Included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaalic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaalicn is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 updated 09/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 4 \jtauIic FireLock® Fittings Alc_t a _U1 i d 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: El Orange enamel El Red enamel in Europe, Middle East, Africa, and India o Optional: Hot dipped galvanized Approvals/Listings: c@us MPM LISTED S Of Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic company. All rights reserved. ictaulic 1 victaulic.com I FireLock® Fittings I Publication 10.03 Dimensions: k-CtoE.1 C to E to E C Ib to NO. 001 NO. 003 NO. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 450 Elbow Straight Tee Cap Approx. Approx. Approx. Approx. Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm mm mm kg mm kg mm kg mm kg 1¼ 1.660 0.82 0.3 32 42.4 - - - - - - 21 0.1 11/2 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76 .1mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 76 1.5 57 1.1 76.2 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 08mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 39.7 mm 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - - 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 139.7 7.9 88.9 5.2 139.7 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 1 11.6 108 9.3 176 1 17.6 1 29 5.8 10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 j4'ctauiic MechanicaI-T STYLES 920 AND 920N Victaulic Mechanical_T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. kwo STYLES 920 AND 920N STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade 1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over -i-140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com vIcTAuuc IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2012 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REVM 4tauIîcr 11,02_I DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N II 00 f Iijjia1ri'i a 1J C j ir j1 i1ir4 ttei2ra {8r 'lia Iflr41i I', 1/2 (a) a 920½ 500 1.50 2.00 2.53 161 5.35 2.75 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 - 3/~ (a) a 920N 500 1.50 197 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) a 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 1 ¼ (a) to 920½ 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2 (a) to 920½ 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2½ x 1/2 (a) § a 920½ 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 - '/4 (a) §a 920N 500 1,50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §a 920N 500 1.50 2.06 2.74 * 1.82 5.64 2.75 2.9 * 25 3450 38.1 52 70 - 46 143 70 1.4 - 1 1/4 I )a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 'I' (a) a 920N 500 2.00 2.28 300 3.25 1.82 6.26 325 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 761 < ½ (a) 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 164 81 1.8 - 1/4 (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 381 56 70 - 57 164 81 1.8 - 1(a) 920N 300 1,50 2.07 2.75 - 2.25 6.46 3.18 3.8 - 25 2065 38.1 53 70 57 164 81 1.7 1¼ (a))] 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 - 1.5 11/2 (a) a 920½ 500 2.00 2.28 3.00 3,31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 > ½ (a) a 920½ 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - 3/4 (a) a 920½ 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 58 156 70 1.6 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 70 1.6 - 1¼ (a) to 920N 500 1.75 2.55 3.25 ' 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 - 156 76 1.8 1.8 11/2 (a) to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 41 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) a 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3½ 2 920N 500 2.50 3.00 J 3.75 244 - 6.72 3.88 '1 3.8 90 50 3450 63.5 76 - 95 62 171 99 I - 1.e TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 4: Available with grooved or female threaded outlet. Specify choice on order. 4: Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a -PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com \/(tauIic° vIclAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11,02 2 REVM CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 MechanicalT® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS iwirs ri1ii1Ti0 FOG 0 t 1k F _____, , __ _______ 1flc TABLE CONTINUED FROM PAGE 2 6-F 4 100 ½ a 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 15 3450 38.1 77 90 68 178 70 1.8 - r_z__1 -- .1 ' raw L 3/. (a) a 920½ 500 1.50 300 3.56 2.59 7.01 2.75 3.7 20 - 3450 38.1 76 90 68 178 70 1.8 - 1 (a) a 920N 500 1.50 2.88 3.56 2.59 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 - GROOVED OUTLET 1 ¼ (a) to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) to 920N 500 2.00 3.28 4.00 4.00 2.59 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 388 • 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2½ (a) t 920 500 275 2.88 400 400 2.69 7.34 4.63 5.8 5.0 55 3450 69.9 73 102 102 68 185 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 400 2.69 7.34 4.63 6.4 T 699 73 - 102 68 186 118 - 2.9 1? 3(a) t 920 500 3.50 3.31 4.50 4.12 2.59 7.73 5.12 8.4 6.4 FEMALE THREADED OUTLET 80 3450 88.9 84 114 105 58 196 130 3.8 2.9 . • - ,• . - . - 108.0 x 1 1/4 (a)0 920N 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 32 3450 445 78 96 - 67 194 78 2.3 1 112 (a)a 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 Provides a direct branch connection at 40 3450 50.8 83 102 - 67 194 83 2.3 - any location where a hole can be cut 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 - 67 194 102 1.9 - 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 A pressure responsive gasket provides - 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 5003.503.31 4.50450 2.63 763 4.88 6.8 6.5 80 920 3450 88.9 84 114 114 67 194 124 3.1 3.0 Request Publication 11.03 for 5 X 114(a)t 500 2.00 4.03 4.75 - 4.75 3.16 9.70 3.69 7.4 7.5 Mechanical-T cross assemblies 125 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) t 920 500 2.50 4.00 475 4.75 3.16 9.70 4.38 8.2 8.0 Pressure rated up to 500 psi/3450kPa 50 3450 63.5 102 121 121 80 245 111 3.7 3.5 on steel pipe; also available for use 2½)a(t 500 2.75 3.63 4,75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 920 3450 699 92 - 121 121 80 246 118 3.8 3.6 T!76.lmma 920 Sizes from 2 x ½"/50 x 15mm 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 245 118 - 3.6 +- ,- '-•0. .0. through 8 x 4/200 x 100 mm 3 (a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 1330 x , 920N 500 2,50 3.75 4.50 3.17 8.00 3.88 8.0 - 3450 63.5 95 114 - 81 203 99 3.6 50 .- 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 - 80 3450 88.9 97 127 - 76 240 135 3.5 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com -,I. AIC-ta-ulid VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV -M 11,023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS I,Ijjt4Tt( 819) I5a F) Id !1 (ri: a 3Jli)9 11r TABLE CONTINUED FROM PAGE 3 139.7 x 1 1/2 t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 - 84 209 83 3.2 - r Iti 3ir.4k !fi1Ib hr4½. IB Ii 2t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 - 95 114 - 84 209 99 4.1 - 6 1¼ (a) 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 >< 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 11/2 (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 __ 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 -17 21/7 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 ______ 65 3450 69.9 110 130 130 94 267 118 38 3.4 76.1 mm 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69,9 105 - 132 94 267 118 - 3.8 3(a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET . •. - . ,. . . .- - 159.0 )< 1 ½ (a) 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 , 112 , 130 - 92 239 83 3.5 - 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 Provides a direct branch connection at 50 3450 63.5 111 130 - 92 239 99 3.6 - any location where a hole can be cut 76.1 mm ' 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 in the pipe ____ 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 A pressure responsive gasket provides 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 - 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe Center of run to end of fitting. Sizes from 2 x ½/SO x 15mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. At-c-ta-uha 11,024 REVM CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS r ______ a cIj Iir4a FhA Ili48 'Iatim 0riL 18t1iL TABLE CONTINUED FROM PAGE 4 1651 x 920N - 500 150 3.88 4.56 3.79 9.34 2.75 8.0 - 3450 38.1 99 116 - 96 237 70 3.6 ar' - s A'iI7 a IJ 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 - 32 3450 44.5 113 130 - 96 237 83 3.8 It 1½(a)tu 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a(t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 ________ 3450 69.9 110 130 132 92 267 118 3.9 3.4 -17 3(a) t 0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 _______ 80 3450 88.9 110 140 130 92 267 135 4.6 3,8 - - t 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 105 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 21/2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET - - - - 76.1 mm a 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 - 159 122 316 116 - 5.3 3(a) t 1 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 Provides a direct branch connection at 80 I 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4a la 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 I 3450 114.3 122 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). A pressure responsive gasket provides t Available with grooved or female threaded outlet. Specify choice on order. the seal * Center of run to end of fitting. Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-I cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' Pressure rated up to 500 psi/3450kPa (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services o LPCB approved for fire protection services Sizes from 2 x W/50 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com /ac-ta-uh-d vIcTAuLIc ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV VA 11+02 5 CARBON STEEL PIPE. HOLE CUT PRODUCTS 11.02 Mechanical-Va Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C. and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Exaggerated for clarity Formulas for Cv ry Values: AP = Q2 Where: Q = Flow (GPM) AP = Pressure Drop (psi) Q = C x Cv= Flow Coefficient Where: Q = Flow (m3/h) AP = Pressure Drop (bar) = Flow Coefficient I Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. www.victaulic.com lic\J$tauIic' VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02. 6 REV.M CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 MechanicalT® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. L1iY1r1J 11D I '--..- Uf It= 21/2 - 6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65- 150 73.0-168.3 2.875 - 4.500 All DF 2755 300 2755 300 2755 300 1999 - - 290 1599 232 2496 362 21/2 -4 65-100 73.0-114.3 2.875 - 4.500 All SF 2065 300 2065 300 2065 300 1999 290 1599 232 2496 362 21/2-4 65-100 73.0-114.3 6.625 4 - 10 2065 300 2065 300 - 2065 - 250 1999 290 1599 232 2496 362 6 150 168.3 6.625 3040 2065 300 2065 300 1724 300 - 1999 290 1599 232 - 2496 362 6 150 168.3 8.625 21/2 10,40 2065 400 2065 2065 1999 - - 1599 145 2496 - 8 200 219.1 8.625 34 10 2755 300 - - 250 - 1000 145 -- - 8 200 219.1 8.625 ' 3040 2065 300 1724 300 1000 145 - 8 200 219.1 2065 2065 1000 NOTES; 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC-TAP II HOLE CUTTING TOOL FOR 4- 8/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5/125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 2 ½/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com \Jtaulic' vlcTAuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REVJA 1102.7 MechanicalT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV M UPDATED 0312012 ictaul VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1102 .1. SIGMA l0 0 opong Products Quality — Service Commitment — Delivered. VA KI ICE, 111 Malleable Threaded Fittings ALL MALLEABLE THREADED FITTINGS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 197- Standard Spec for Cupola Malleable Iron ASTM A 153- Standard Spec for Zinc Coating (Hot Dip) on Iron and Steel ANSI B 16.3- Malleable Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Ductile Iron Threaded Fittings ALL DUCTILE IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 536- Grade 65-45-12 ASME B 16.3- Ductile Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Cast IronThreaded Fittings ALL CAST IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 128- Class B Standard Spec for Cupola Cast Iron ANSI B 16.4- Cast Iron Threaded Fitting Classes 125 ANSI/ASME BI.20.1- Pipe Threads, General Purpose (Inch) NPT Steel Pipe Nipples ALL STEEL PIPE NIPPLES MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 53- Standard Spec for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamed ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT www.slgmaco.com O Dimensions: ANSI 816.3 CLASS 150 []Coating: Black- none: Galvanized- Hot Dip per ASTM A153 O Material: Malleable iron per ASTM A197 []Threads: Pipe Threads, General Purpose ASME 81.20.1 Description F77 Malleable Threaded 90 1 1[tMUt 1 1ffENIUN1 F SIZE [BLACK ir [J[B1 WHT A 3/8" 1M90B0303 1M9080303G 0.95 0.95 0.17 - 1/2" 1M90B0404 1M9080404G 1.12 1,12 0.30 3/4" 1M90BO505 1M9080505G 1.31 1.31 0.45 1" 1M9080606 1M90806060 1.50 1,50 0.73 I - 11/4" 1M90B0707 1M9080707G 1.75 1.75 0.97 1 1/2" 1M9080808 1M9080808G 1.94 1.94 1.30 / B 2" 1M90B0909 1M90B0909G 2.25 2.25 2.06 2 1/2" 1M9OB1O1O IM9OBIO1OG 2.70 2.70 3.55 3" 1M90B1111 IM9OBIII1G 3.08 3.08 5.46 LISTED 1M9081212 1M90B12120 3.79 3.79 8.95 Description I Malleable Threaded 45 NOM I ITEM U 1FmMENiUN1 ITE 62E IFFEAUK-11ALV J[ JEB1 WHT 3/8" 1M4580303 1M4580303G 0.80 0.80 0.16 A 1/2" 1M4580404 1M45B0404G 0.88 0.88 0.22 3/4" 1M4580505 1M4580505G 0,98 0,98 0.37 1" 1M4580606 1M4580606G 1,12 1.12 0.54 1 1/4" 1M4580707 1M4580707G 1.29 1.29 0.86 11/2" 1 M4580808 I M45B0808G 1,43 1.43 1.13 2" 1M4580909 1M4580909G 1.68 1.68 1.79 2 1/2" 1M45B1010 1M45B1O1OG 1.95 1.95 2.78 YL :' 1M4581111 1M4581111G 2,17 2.17 4.48 LISTED ' 1M4581212 1M45B12126 2.61 2.61 7.40 Description I I Malleable " hreed90 rNUM1t ITEM OUE IFDTMNlON I s J1 BLACK J[ GALV 1E1[ I WEIGHT 3/8" 1M90S0303 1M90S0303G 0.80 1.00 0.17 1/2" 1M90S0404 1M90S0404G 0.88 1.13 0.24 314" 1M90S0505 1M90S0505G 1.00 1.31 0.41 I 1M90S0606 1M9050606G 1,23 1.44 0.62 B / 1 11/4" 1M90S0707 IMSOSO7O7G 1.31 - 1.69 1.09 f 1112" 1M90S0808 1M90S0808G 1.44 1.88 1.44 11- 11 1M90S0909 1 M9080909 1.69 2,25 2.85 -A--i LISTED . Description I I Malleable Hex Nut NUM I ITEM CODE 1 FIFEM SIZE [BLACK JLGALV J W1(3HT 1/2" IMLN04 IMLN04G 0.12 314" 1MLN05 IMLN05G 0.22 /1 1" 1MLN06 1MLN06G 0.38 ) 1 0 11/4" 1M1N07 1MLN07G 0.58 @ 1 1/2" 2' : LN :: 0.73 LISTED www.sigmaco.com Malleable Threaded Description I Description [ Malleable Threaded Tee Description I I Malleable Threaded Cross A A L ffEMUE DIJIM. I [SLACK J[ GALV] A 1 MT020202 I MT020202G 0.81 I MT030303 I MT030303G 0.94 1MT040404 1MT040404G 1.13 1MT050505 1MT050505G 1.31 I MT060606 I MT060606G 150 1 MT070707 1 MT070707G 1.75 I MT080808 1 MT080808G 194 1 MT090909 1 MT090909G 2.25 IMT101010 IMT10I01OG 2.69 1MT111111 1MT111111G 3.06 1MT121212 1MT121212G 3.81 ITEM MEYE I1tJIM. I [BT..ACK j[ ALV IMX04 IMXO4G 1.12 IMXOS IMX05G 1.13 1MX06 IMXO6G 1,50 IMXO7 IMXO7G 1.75 1MX08 IMXO8G '1,94 I MXO9 I MXO9G 2.25 IMX10 1MXIOG 2.70 IMXII 'IMXIIG 3.08 www.sigmaco.com Malleable Threaded FftUng_ Description I Malleable Reducing Tee NOM rJIME-19. E A]mEc"1 -- C 112"X 1/2"X 3/8" 1MT040403 1MT040403G 1.06 1.06 1.06 0.30 3/4" X 1/2" X 1/2' 1MT050404 1MT0504046 1.08 1.08 1,09 0.38 3/4" X 1/2' X 3/4" 1MT050405 1MT050405G 1.11 1.11 1.13 0.46 3/4" X 3/4" X 1/2" 1MT050504 1MT050504G 1.19 1.19 1.25 0,47 B I 1" X 1/2" X 1/2" 1M1060404 1MT060404G 1.21 1.21 1,30 0.58 1" X 3/4" X 1/2" 1MT060504 1MT060504G 1.22 1.22 1.32 0,59 1" X 3/4" X 3/4" 1MT060505 1MT060505G 1.23 1.23 1.33 1.59 1"X 1"X 1/2" 1MT060604 1MT060604G 1.25 1.25 1.38 0.70 I 1" X 1" X 3/4" 1MT060605 IMT060605G 1.38 1.38 1.44 0.82 A I 11/4" X 1" X 1" 1MT070606 1MT070606G 1.56 1.56 1.69 1.10 1 1/4"X 11/4" X 1/2" 1MT070704 1MT070704G 1.38 1.38 1.56 0.98 1 1/4" X 1 1/4" X 3/4" 1M1070705 I MT0707050 1.40 1.40 1.80 0.94 11/4" X 11/4" X 1" 1M1070706 1MT070706G 1.56 1.56 1.69 1.20 11/2" X 11/4" X 1" 1MT080706 1MT0807066 1.63 1.63 1.81 1.30 UL 11/2" X 11/2" X 1/2" 1MT080804 1MT080804G 1.44 1.44 1.69 1,19 1 1/2"X I 1/2X3/4" 1MT080805 1MT080805G 1,50 1.50 1.75 1.30 LISTED 1 1/2"X1 1/2"XI' 1MT080806 1MT080806G 1.63 1.63 1.81 1.45 11/2" X 11/2" X 1 1/4" 1MT080807 1MT080807G 1.81 1.81 1.88 1.52 2" X 2" X 1/2" 1MT090904 1 MT090904G 1.50 1.50 1.88 1,65 2" X 2" X 3/4" 1 MT090905 I M1090905G 1.63 1.63 2.00 1,87 2"X2"X 1" 1MT090906 1MT090906G 1.75 1.75 2.00 1.76 2" X 2" X 11/4" 1M7090907 1MT090907G 1.88 1.88 2.13 2.35 2" X 2" X 1 1/2" 1M1090908 1MT090908G 2.00 2.00 2.19 2.55 21/2" X2 1/2"X 1" 1MTI0I006 1MTI01006G 1.88 1,88 2.38 2.85 21/2" X2 1/2"X 11/4" IMT1010071MT10I0076 2.06 2.06 2.44 3.36 2 1/2 X 2 1/2 X 1 1/2 1M1101008 1MT101008G 2.19 2.19 2.50 3,46 2 1/2" X 2 1/2" X 2" 1MT101009 IMTI0I0096 2,38 2.38 2.62 3.65 • 3"X3"XI/2" 1MT111104 IMTI11104G 1.76 1.76 2.52 4.03 3" X 3" X 3/4" 1MT111105 1MT111105G 1.88 1.88 1.63 4.03 3" X 3" X 1'" IMT1III06 IMTI1II06G 2.00 2.00 2.62 4.13 3"X 3" X 11/4" 1MT111107 1MT111107G 2.19 2.19 2.75 4.50 3" X 3" X 11/2" 1MT1I1I08 1MT11I108G 2.31 2.31 2,81 5.18 3"X3"X2" 1MT111109 1MT111109G 2.50 2.50 2.88 5.70 3" X 3" X 11/2" 1MT111110 1MT111110G 2.57 2.57 2.89 5.00 4" X 4" X 11/4" 1MT121207 1MT121207G 2.39 2.39 3.26 7.47 4" X 4" X 1 1/2"' 1MT121208 1MT1I1208G 2.51 2.51 3.32 7,47 4" X 4" X 2" 1MT121209 1MT121209G 2.75 2.75 3.44 8.39 4"X4"X2 1/2" ' 1MT121210 1MT12121OG 2.75 2.75 3.44 7.70 4"X 4'X 3" 1MT121211 1M71212113 3,31 ' 3.31 3.63 8.93 Description I I Malleable Cap LISTED L UQ ITEM C 1 SIZE I BLACK JI (ALV J W1HT 1/2" IMKO4 1MKO4G , 0.14 3/4" IMKOS 1MK05G 0.21 1" IMKO6 1MKOBG 0.37 1 1/4" IMK07 IMK07G 0.58 11/2" 1M<08 , IMK08G 0.74 2" IMKOO 1MK09G 0.94 2 1/2" IMKIO 1MK10G 1,60 3" 1MKI1 IMKIIG 2.79 4" 1MKI2 IMK12G 3.66 www.sigmaco.com I ITIM1XJLE lfl:JIM. i ITEM SIZE BLACK IEGALV IF--A-71 WEJC3HT 3/8" 1MCP0303 1MCP0303G 1.18 0,13 1/2" IMCP0404 1MCP0404G 1.31 0.20 3/4" 1MCP0505 IMCP0505G 1.50 0.30 1" 1MCP0606 1MCP0606G 1.69 0.48 1 1/4" IMCP0707 1MCP0707G 1.93 0,75 1 1/2" 1MCP0808 1MCP0808G 2.13 1.00 2" 1MCP0909 , IMCP0909G 2.50 1,45 2 1/2" 1MCP10I0 1MCP10100 2,88 2.40 3" 1MCP1111 1MCP1111G 3.19 3,30 4" IMCP12I2 1MCPI2I2G 3.69 5,72 Malleable Coupling 9 Description I I Malleable Threaded Fittings________________ Description I I Malleable Reducing Coupling 1/2" X 3/8" 1MCR0403 IMCRO403G 0.17 0.17 3/4' X 1/2" IMCRO504 IMCRO504G 0.27 0.27 1"X 1/2" 1MCRO604 IMCRO604G 0.39 0.39 1" X 3/4" 1MCR0605 1MCRO6O5G 0.43 0.43 1 1/4" X 1/2" 1MCR0704 1MCR0704G 0,61 0.61 1 1/4" X 3/4" IMCR0705 1MCR0705G 0.64 0.64 1 1/4" X 1" IMCR0706 IMCR0706G 0.68 0.68 U 1 1/2" X 1/2" IMCRO804 1MCR0804G 0.78 0.78 1 1/2" X 3/4" IMCRO805 1MCR0805G 0.88 0.88 USTED 1 1/2" X 1" 1MCR0806 IMCR0806G 0.88 0.88 11/2" X 11/4" IMCR0807 1MCRO807G 0.90 0.90 2" X 1/2" 1 MCRO904 I MCRO904G 1.15 1.15 2" X 3/4" 1 MCRO905 . I MCRO905G 1.34 1.34 2" X 1" 1 MCR0906 1 MCRO906G 1.40 1,40 2" X 11/4" 1MCRO907 IMCRO907G 1.53 1.53 2"X 11/2" 1 MCRO908 I MCRO908G 1.55 1.55 2 1/2" X 1 1/4" 1MCRI007 IMCR1007G 2.09 2.09 2 1/2" X 1 1/2" IMCRI008 IMCRI008G 2.09 2.09 2 112"X2" IMCRIO09 IMCR1009G 2.51 2.51 3" X 1 1/4" 1MCRI107 IMCR1107G 2.99 2.99 3" X 11/2" IMCRI108 1MCR1108G 3.30 3.30 3" X 2" IMCR1109 1MCR1109G 3.25 3.25 3" X 2 1/2" IMCR1II0 , 1MCR1110G 3,29 3.29 4"X 1 1/2" 1MCR1208 IMCRI208G 4.90 4,90 4" X 2" IMCRI209 IMCR1209G 5,10 5.10 4" X 2 1/2" IMCRI210 IMCR12IOG 6.55 6.55 4"X3" IMCRI2I1 1MCRI2IIG 4.04 4.04 P401Qr1 L ITEM Ct1DE I1D1MENfl[1M1 I SIZE J[ BLACK 11 GALV iEiE1L WIHT 1/2" IMFF04 1MFF04G 3.50 2.50 0.56 3/4" 1MFF05 1MFF05G 3.50 2.50 0.60 IMFF06 IMFF06G 4.00 3.0 0.84 1 1/4" 1MFF07 1MFF07G 4.00 3.00 0.90 1 1/2' IMFF08 , IMFF08G 4,50 3.50 1.20 IMFF09 IMFFO9G 5.50 4.25 2.03 Description L I Malleable Floor Flange B A www.slgmaco.com LiSTEU NOM SIZE ITEMCQUE [BLACK J[ 'T GALV WFIHT 1/2" X 1/4" IMBSH0402 1MBSH0402G 0.06 1/2"X 3/8" IMBSH0403 1MBSH0403G 0.05 3/4" X 1/2" IMBSH0504 IMBSH0504G 0.11 1"X 1/2" IMBSH0604 1MBSH0604G 0.21 1" X 3/4" 1MBSH0605 1MBSH0605G 0.17 1 1/4" X 1/2" 1MBSH0704 1MBSH0704G 0.34 1114" X 3/4" IMBSH0705 1MBSH0705G 0.31 1 1/4" X 1" 1MBSH0706 IMBSH0706G 0.26 1 1/2" X 1/2" IMBSH0804 1MBSH0804G 0.48 1 1/2" X 3/4" 1MBSH0805 IMBSHO8O5G 0.48 11/2"X 1" IMBSH0806 1MBSH0806G 0.43 1 1/2" X 1 1/4" 1MBSH0807 IMBSHO8O7G 0.30 2" X 1/2" 1MBSH0904, 1MBSHO9O4G 0.65 2" X 3/4" 1MBSF40905 1MBSHO9O5G 0.83 2" X 1" IMBSH0906 1MBSH0906G 0.78 2" X 1 1/4" IMBSH0907 1MBSH0907G 0.73 2" X 11/2" 1MBSH0908 IMBSH0908G V 0.60 2 1/2"X 11/4" IMBSH1007 1MBSH1007G 1.30 2 1/2"X1 1/2" 1MBSHI008 1MBSHI008G 1.20 2 1/2" X 2" IMBSNI009 V V IMBSH1009G 0.90 3" X 1 1/4" 1MBSHI107 1MBSH1107G V 2.50 3"X 1 1/2" IMBSHII08 V 1MBSHII08G 2.30 3"X2' IMBSI-I1109 V 1MB5H1109G 2.00 V 3"X2 1/2" IMBSHII10 IMBSH11IOG 1.60 4" X 1 1/4" V IMBSFII207 IMBSI-I1207G 3.20 4" X 11/2" V 1MBSH1208 V IMBSHI208G 3.30 4"X2" V 1MBS11209 IMBSHI209G 3.10 4" X 2 1/2" 1MBSH1210 'IMBSH1210G 3.80 4" X 3" 1M55H1211 tMBSH1211G 3.00 Description 1 1 Malleable Bushings 1E Malleable Threaded Ffttings - 1 Description [ 1 Malleable Plug ENOM1I 1 1 ITEM I SIZE if-MACK J1 GAIN 1 I WIGHT 3/8' 1MPLG03 1MPLG030 0.06 1/2" IMPLGO4 1MPLG04G 0.10 3/4" 1MPLGO5 1MPLG05G 0.17 IMPL.G06 IMPLG06G 0.28 1 1/4' 1MPLG07 IMPLGO70 0.44 1 1/2" IMPLGO8 1MPLG08G 0.62 1MPLGO9 1MPLG09G 0.91 21/2" 1MPLG1O 1MPLGIOG 1.05 1MPLGII IMPLG1IG 1.70 1MPLG12 1MPLGI2G 3.00 www.sigmaco.com Malleable Threaded Attings Description F I I ITEM 1UEIE iID1M. SIZE BLAci J[ GALV irAi I TEM WEIGHT Malleable union 1/4" IMUN02 IMUN02G 1.81 0.45 A 3/8" 1MUN03 1MLJN03G 1.81 0,42 1/2" 1MIJN04 IMUNO4G 1.94 0.44 3/4" 1MUN05 IMLJNOSG 2,06 0,60 IMUN06 IMUN06G 2,44 0.91 1 1/4" 1MUN07 1MUN07G 2.63 1.45 11/2" IMLJN08 IMUN08G 275 1.69 IMUN09 IMUN09G 2,94 2.46 1MUN1I 1MUN11G 3.63 4.95 LISTED 1MLJN12 IMUN12G 3.75 8.75 Description L I'll® LISTED i[F.M tME IflU1M1 SIZE [BLACK][ GALV J J WgjGHT 1/4" IMUNBS02 1MUNBS02G 1.81 0.45 3/8" IMUNBS03 IMUNBS03G 1.81 0.42 1/2" 1MUNBS04 IMUNBS04G 1.94 0.44 3/4" IMUNBS05 1MUNBS05G 2.06 0.60 IMUNBS06 IMUNBS06G 2.44 0.91 1 1/4" IMUNBS07 1MUNBS07G 2.63 1.45 1 1/2" IMUNBS08 1MUNBS08G 2.75 1.69 IMUNBS09 1MUNBS09G 2.94 2.46 1MUNBS11 1MUNBS11G 3.63 4,95 1MUNBSI2 1MUNBS12G 3.75 8.75 Malleable Union wl Brass Seat A Description L I [NUM I 1TEMaDE 11DIM. J IThM Malleable Extension [ SIZE [ BLACK J[ GAIN ] A71 WEIGHT A 1/2" 1MEX04 IMEX04G 1.95 7.32 www.slgmaco.com LAM fETM cDE1i DIM. ] NOM SIZE:-' flTM ULACK JE1vE1H.. 1 1/4" 1DCP070 .5 12 11/2" 2" .5 24 7 10CP0808 10CP0606 1 DCPO9O9 2.25 1.75 1.94 1.50 ©1 iUc LLir['~Ijlmadedo Ffflng% O Notice: D.I. Fittings have higher tensile strength then 0,1. Threaded fittings are UL cUL listed and Factory Mutual that of steel pipe, over tightening can cause damage approved for SOOpsi servce. 0.1. Per ASTM A 536 grade 65-45- to pipe threads which may cause leakage. 0.1. Fitting 12. Dimensions conform to ANSI B16.3 Class 150. Threads are should be tightened three turns beyound hand tighten, NPT per ANSI/ASME 8I.20.1 no more than four turns. Description I D. 90 Degreod Elbow W1 NOM SIZE [BlACK-Jima--i EIGH 11)90130606 1.50 1,50 0.62 11/4" 109080707 1.75 1,75 0.90 11/2" 109080808 1,94 1.94 1.20 109080909 2,25 2.25 1.85 Description I D. 1. Straight Tee AlA B[ftJLd urn IFItM GU1Jbf UtMNSIN1I ITEMNOM SIZE L BLACK J[ A J[ 1DT060606 1.50 1.50 0.85 1 1/4" 1DT070707 1.75 1.75 1.22 1 1/2" 10T080808 1.94 1.94 1.55 1DT090909 2.25 2.25 2.45 Description F D.I. Coupling rsn Description I D. Red, 90 Deg.Elbow NOM SIZE [BLACK IrA IEB1I.H. I X112" 1D90R0604 1.26 , 1.36 0.44 1 X 3/4" 1090R0605 1.37 1.45 0.52 1 1/4 X 1/2" ' 1D90R0704 , 1.34 1,53 0.64 1 1/4 X 3/4" 1090R0705 1.45 1.62 0.72 I 1/4")( 1" , 1090R0706 1,58 1,67 0.75 1 1/2" X 1" 11390R0806 1.65 1.80 0.92 1 112"X 11/4" 1090R0807 1.82 1.88 1.08 2"X 1/2" 1090R0904 1.49 1.88 1.08 2" X 3/4" , 1090R0905 1.60 1.97 1.24 2'X 1" 1090R0906 1.73 2.02 1.40 2" Xl 1/4" . 1090R0907 1.90 2.10 1.52 2" X 1 1/2" 1090R0908 2.02 2.16 1.65 gem Description! D.I. Reducing Coupling TTJ 'NOM SIZE IID1h IMMI1 [BLACK II A _K11 1 X 1/2" 10CR0604 1.69 0.39 , I X 3/4" IDCRO605 1.69 0.53 Description I D. 45 Degreed Elbow I IFIM ZEi DIMENRN1 [NOM SIZE fl FM [BLACK J[A.JE91EIGI 104580606 1.12 1.12 0.46 1 1/4" 1D45B0707 1.29 1.29 0.73 1 1/2" 1D45B0808 1.43 1.43 0.92 1045B0909 1.68 1.68 1.50 gem www.sigmaco.com Ductile Iron Threaded Fittings____________________ Description I D. 1. Bushing wo I A A OUTSIDE HEAD INSIDE HEAD ILTEM coDE1u:JIMENSIOW1I 1PTEMI F5M SIZE _ETETt1sIYL11 wr. I X112" 108US0604 0,75 0.25 1,42 OUT 0.22 I X 3/4" 1DBUS0605 0.75 0.25 1,42 OUT 0.17 1 1/4" X 1" IDBUS0706 0.80 0.28 1.76 OUT 1.28 1 1/2"X I" 1DBUS0806 0.83 0.31 2.00 OUT 0.44 11/2" X 11/4" 108US0807 0.83 0.31 2.00 OUT 0.30 2"X 1" IDBUS0906 0.88 0.41 1.95 IN 0.66 2" Xl 1/4" IDBUS0907 0.88 0.34 2.48 OUT 0.72 2"X 1 1/2" 1DBUS0908 0.88 0.34 2.48 OUT 0.61 Description I D. Cross -k Una B--B- A [JiA F&i EMI DIMENSION I[TtEM SIZ WLACK II A JrB1'vJQH 1DX0606 1.50 1,50 0.98 11/4" 10X0707 1.75 1.75 1.50 1 1/2" 1DX0808 1.94 1 1.94 1.90 1DX0909 2.25 2.25 2.95 1 1/4"X 1" 1DX0706 1.58 1.67 1.27 1 1/2' X 1" 1DX0806 1.65 1,80 1.45 2" X 1" 1DX0906 1.73 2.02 2.10 Description I D. Cap U Um tiuMCUt1E1I DIM I NOM SIZE BLACK iri EiH.. 101(06 1.16 0.32 1 1/4" IDKO7 1,28 0.43 1 1/2" 1DK08 1.33 V 0.60 IDK09 1.45 0.91 www.sigmaco.com Description I D. I. Reducing Tee CL Me J f_____ NOM SIZE ]UTEMGUDEJI DIMENSION I 1" x 1"x 1/2" 10T060604 126 1.26 1.36 0.64 lx 1"x 3/4" 101060605 1.37 1.37 1.45 0.73 1" x 1/2" x 1" 101060406 1.50 1.36 1.50 0.71 1"x 3/4" xl" ' 101060506 1.50 1.45 1.50 0,76 1"x 1" x 1 1/4" 101060607 1,67 1.67 1.58 0.98 1"x 1"x 11/2" 10T060608 1,80 1.80 1.65 1.16 11/4" x 1" x 1/2" 1D1070604 1,34 1.26 1.53 0.82 1 1/4" x 1"x 3/4" ' 101070605 1,45 1.37 1.62 0.90 11/4" x 1" x 101070606 1.58 1.50 1.67 1.00 1 1/4" x 'I" x 11/4" 101070607 1.75 1,67 1.76 1.08 11/4" xl" xl 1/2" 10T070608 1,88 1.88 , 1.82 1,42 I 114"x I 1/4"x 1/2" 101070704 1.34 1.34 1.53 0.86 1 1/4" x 1 1/4" x 3/4" 101070705 1.45 1,45 1.62 0.92 1 1/4"x I 114"x 1" 1D1070706 1.58 1,58 1.67 0,95 1 1/4" x 11/4" x 1' ' 101070708 ' 1,88 1.88 1,82 1.45 1 114"x I 114"x2" 10T070709 2,10 2.10 1.90 1.75 11/2" x1" x 1/2" '• 101080604 1.41 1,34 1.66 0,95 I 1/2"x l"x3/4" 101080605 1.52 1,37 1.75 1,14 11/2" xl" x , 101080606 1.65 1.50 1.80 1.17 11/2" x I" x 11/4" 1D1080607 ' 1.82 1.67 1.88 1.34 11/2" x 1" x 11/2" 10T080608 1.94 1.80 1.94 1.45 11/2" x 11/4" x 1/2" 1D1080704 1,41 1.34 1.66 1.05 1112" x 114"x3/4" lDT080705 1.52 1.45 ' 1,75 , 1,15 I 1/2"x I 1/4"x I" ' 101080706 1.65 1.58 1.80 1.25 11/2" x 1/4" x 2" 1DT080709 2.16 2.10 2.02 1.90 1 1/2" x 1 1/2" x 1I2 1 D1080804 1.41 1.41 1.16 1.15 1 1/2" x 1 1/2" x 3/4" 10T080805 1.52 1.52 1,75 1.24 I 1/2"x 1112" x 1" 101080806 1.65 1.65 1.80 1.30 11/2" x 1 1/2" x 1" 101080807 1,82 1.82 1.88 1.48 I 1/2"x1 1/2"x2" 10T080809 2.16 2.16 2.02 1.98 2"x 1"x 2" 101090609 2.25 , 2.02 2.25 2.15 2"x 1 1/4'x 2" 101090709 2.25 2,10 2.25 2.30 2" x 11/2" x 1/2" 101090804 1.49 , 1,41 1.88 1.50 2" x 11/2" x 3/4" 101090805 1,60 1.52 1.97 1.62 2" x 1/2" x1" 101090806 1.73 1 1,65 2.02 1.64 2"x 11/2" x 11/4" 101090807 1,90 1.82 2.10 1.80 2" x 1 1/2" x 11/2" ' 10T090808 2.02 V 1.94 2.16 , 2.00 2" x I 1/2" x 2" 1D1090809 2,25 2,16 2.25 2.35 2" x2" x 1/2" , 101090904 1 1,49 1.49 1,88 1.60 2" x Tx 3/4" 101090905 1.60 1.60 1.97 1.68 2"x2" x1" 101090906 1,73 1.73 2.02 ' 1.85 2" x 2" x I 1/4" ' 101090907 1,90 1.90 2,10 2.04 2" x 2" x 1 1/2" 101090908 2.02 2.02 2.16 2.18 2" x Tx 2 1/2" 101090910 2.60 2,60 2.39 3,61 2 1/2" x 2" x 3/4" 101100905 1,74 1.60 2,32 2.28 ctel-M TL© fl C.I. Threaded fittings are UL cUL listed and Factory Mutual approved for 300psi servce. Gray iron per ASTM 126 class B. Dimensions conform to ANSI B 16.4 Class 125 except plugs conform toASME B 16,14. Threads are NPT per ANSI/ASME 13I.20.1. Description I I C. 90 Degreed Elbow B -j- A fILM E1fflfWN1Ufl 'ITEM NOM SIZE [BLACK II A]EWJ giuij 1" 1C90B0606 1,50 1.50 0,85 11/4" 1 C90B0707 1.75 1.75 1.22 1 1/2' 1 C90B0808 1,94 1.94 1.55 2' 1C90B0909 2.25 2.25 2.45 2 1/2" 1C90B10I0 2.70 2.70 4.80 Description L- C. 1. Straight Tee A A T O TB Ll Jl -II I LM 'UL1E1i UIMNS1UN1 NOM SIZE j BLACK j[][ Ji EIGH 1' 1CT060606 1.50 1.50 0.85 11/4' 1 CT070707 1.75 1.75 1.22 11/2" 1CT080808 1.94 1.94 1.55 2" 1CT090909 2.25 2.25 2.45 2 1/2" ICTIO101O 2,70 2.70 6.39 Description L I C. Reducing Coupling FIUJI L4& UTI I j SIZE NOM vILM M.1 ITEM 1 0 S [BLACKJ[ A JV1Gklli I X 1/2" 1CCRO604 1.69 0.62 I X 3/4" 1CCR0605 1.69 0.69 Description I Reducing C.I. Degreed Elbow 4I NOM SIZE I1TtM JrJ1E1jMEIpN i1 1u'M1 - [ !CW1EAflEflVH11 I X1/2" 1C90R0604 1.26 1.36 0.44 I X 3/4" 1C90R0605 1.37 1,45 0.52 11/4X1/2" 1C90R0704 1.34 1.53 0.64 1 1/4 X 3/4" 1C90R0705 1.45 1.62 0.72 1 1/4" X 1" 1C90R0706 1.58 1,67 0.75 11/2" X 1/2" 1 C90R0804 1.60 1.70 1.17 1 1/2"X3/4" 1C90R0805 1.61 1.72 1.30 1 1/2" X 1" 1C90R0806 1.65 1.80 0.92 1 1/2"X1 1/4" 1C90R0807 1.82 1.88 1.08 2"X 1/2" 1C90R0904 1.49 1,88 1.08 2" X 3/4" 1C90R0905 1.60 1.97 1.24 2" X 1" 1C90R0906 1.73 2.02 1.40 2" Xl 1/4" 1C90R0907 1.90 2.10 1.52 2" X 1 1/2" 1C90R0908 2.02 2,16 1.65 Description I I C.!. 45 Degreed Elbow rwo-~ SIZi utMNsIoIflI ITEM BLACK J[ A J11JH. 1C45B0606 1.12 1,12 0.46 1 1/4" 1C45B0707 1.29 1.29 0.73 1 1/2" 1C45B0808 1.43 1.43 0.92 1C45B0909 1.68 1.68 1.50 www.sigmaco.com Description I C. Plugs -1 FTrEM7 NOM SIZE I BLACK J[ A J 1/2" lCPLG0404 0.94 0.10 3/4" ICPLGOSOS 107 0.17 1CPLG0606 1.25 0.28 1 1/4" ICPLG0707 1,36 0.44 1 1/2" 1CPL00808 1.45 0,62 1 1CPLG0909 1.56 0.91 Description F C. 1. Cross A A F6M SIZE1 M DIMhN1UN 11 [ BLACK1[ A it Es ITEM 1 1CX0606 1.50 1.50 1.54 1 1/4" 1CX0707 1.75 1.75 2.40 1 1/2" ICX0808 1.94 1.94 3.10 ' 1CX0909 2.25 2,25 4.00 111/4" X 1" lCX0706 1.58 1,67 2.05 1 1/2" X 1" 1CX0806 1.65 1.80 2.40 2" X 1" ' lCX0906 1.73 2.02 2.75 0.95 1.10 1.08 1.18 1.52 1.73 1,17 1,38 1.47 1.80 2.05 1.37 1.54 1.65 2,21 2.55 1,41 1.65 1.65 2.00 2.30 1.58 1.72 1.85 2.22 2.45 2.80 1.76 1.87 1.94 2.29 3.28 3.40 2.80 2.09 2,40 2.54 2.85 2.24 3.75 2.60 2.71 2.97 3.32 3.72 5.10 Cast Iron Threadecwtngs Description t CI. Reducing Tee - C NOM 0 SIZE 1" x 1"x 1/2" 1CT060604 1,26 1,26 1.36 1" x I" x 3/4" 1C1060605 1,37 1.37 1.45 lx 1/2" x 1" 1CT060406 1.50 1.36 1,50 1"x3/4"x1" lCT060506 1,50 1,45 1.50 1" x 1' x 1 1/4" 1CT060607 1.67 1.67 1,58 I" x 1" x 1 1/2" 1CT060608 1.80 1.80 1.65 1 1/4" x lx 1/2" 1C1070604 1,34 1,26 1.53 1 1/4" x lx 3/4" ' 1CT070605 1,45 1,37 1.62 1 1/4 x 1' x 1" , 1C1070606 1.58 , 1.50 1,57 11/4" x I" x 1/4" 1CT070607 ' 1.75 1.67 1,75 1 1/4" x 1" x 1 1/2" 1C1070608 1.88 1.80 1.82 1 1/4" x 1 1/4" x 1/2" 1C1070704 1.34 1.34 1.53 1 1/4" x 1 1/4" x 3/4" 1C1070705 1.45 1.45 1.62 1 1/4" x 1 1/4" x 1" 1CT070706 1.58 1.58 1.67 1 1/4" x 1 1/4" x 1/2" 1CT070708 1.88 1.88 1.82 1 1/4" x 1 1/4" x 2" 1CT070709 2,10 2,10 1,90 I 1/2"x1"x1/2" 1CT080604 1.41 1.34 1.66 1 1/2" x 1" x 3/4" 1CT080605 1.52 1.37 1.75 11/2" x I" x 1" 1CT080606 1.65 1,50 1.80 I 1/2"x 1"x 11/4" 1CT080607 1.82 1.67 1.88 1 1/2" x 1" x 1 1/2" 1C1080608 1.94 1.80 1.94 1 1/2" x 1 1/4" x 1/2" 1C1080704 1.41 1.34 1.66 1 1/2" x 1 1/4" x 3/4" 1C1080705 1.52 1.45 1.75 1 1/2" x 1 1/4" x 1" 1CT080706 1.65 1.58 1.80 1 1/2"x1 1/4"x1 1/4" 1C1080707 1.82 1.75 1.88 I 1/2"x 1 1/4"x 11/2" 1CT080708 1.94 1.88 1.94 1 1/2" x 1 1/4" x 2" 1CT080709 2.16 2.10 2.02 1 1/2" x 1 1/2" x 1/2" 1CT080804 1.41 1.41 1.66 1 1/2" x 1 1/2" x 3/4" 1CT080805 1.52 1.52 1.75 1 1/2" x 1 1/2" x 1" 1CT080806 1.65 1.65 1.80 I 1/2"xl I/2"x1 I/4 1CT080807 1.82 1.82 1.88 1 1/2" x 1 1/2" x 2" 1CT080809 2.16 2.16 2.02 2" x I" x 2" 1CT090609 2.25 2.02 2.25 2" x 1 1/4" x 2" 1C1090709 2.25 2.10 2,25 2" x 11/2" x 1/2" 1C1090804 1.49 ' 1,41 1,88 2" x 11/2" x 3/4" 1CT090805 1.60 1.52 1.97 2"x 1 1/2"x I" 1C1090806 1.73 1.65 2,02 2" x 1 1/2" x 11/4" 1CT090807 1.90 1.82 2.10 2" x 1/2" x 1/2" 1CT090808 1,49 1.41 1,88 2" x 1 1/2" x 2" 1CT090809 2.25 2.16 2.25 2" x 2" x 1/2" 1CT090904 1.49 1.49 1.88 2" x 2" x 3/4" 1C1090905 1.60 1.60 1.97 2" x 2" x1" 1C1090906 1.73 1.73 2.02 2" x 2" x 1 1/4" 1C1090907 1.90 1.90 2.10 2" x 2" x 1 1/2" 1C1090908 2.02 2.02 2.16 2" x 2" x 2 1/2" 1C1090910 2.60 2.60 2.39 wwwslgmaco.com u m -, I M a P-3 I I po U a a •© E] Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME 81 .20.1 Description I Black Steel ENGTH FL [ 11W' J[ TId" II 318' II NOMINAl.. 1/2" SIZE j[ 3/4" F - " [ 1 174" J[ 1112" J[ 2" ] CLOSE V INB0I01 INB020I IN80301 1NB040I 1NBO501 INB060I INBO701 1NBO801 1NB0901 1 1/2" 1NB0108 1NB0208 1N80308 1NB0408 1NB0508 NA NA NA NA 2" 1NBO109 1N80209 1NB0309 1NB0409 1N80509 I B0609 1NB0709 1NB0809 NA 2 1/2" 1NBOII0 1N802010 INB0310 1NB04I0 1N80510 1N80610 IN807I0 1N80810 IN80910 3" 1N80111 INB0211 INBO311 INBO41I INBO511 , 1NBO6II 1NB0711 1NBO8I1 1NB0911 3 1/2" 1N801115 1NB0211-5 1NB0311-5 1NB04115 IN8051I-5 INBO6II-5 1NB07I1-5 1NBO811-5 1NB0911-5 4" 1NBO112 1 N8021 1N80312 1NB0412 1NB0512 1NB0612 1NB0712 1NB0812 , 1NB0912 4 1/2" 1N80112-5 1N80212-5 1N80312-5 1NB04125 1N80512-5 IN80612-5 1N807125 1NB0812-5 1N80912-5 5" 1N60113 1NB0213 1NB0313 1NB0413 1N80513 , 1N80613 1N80713 1NB0813 1NB0913 1/2" 1N80113-5 1NB0213-5 1N80313-5 1NB0413-5 1NB0513-5 1NB0613-5 1NB0713-5 1N80813-5 1NB0913-5 6" V 1NB0114 1NB0214,1NB0314 1NB0414 1N80514 1NB0614 1NB0714 1NB0814 1NB0914 6 1/2' 1NBOI14-5 1NB0214 .5 1NB0314-5 1N80414-5 1NB0514-5 INBQ614-5 1NB0714-5 1N80814-5 1NB0914-5 7" NA NA NA NA NA 1NB06147 1NB07147 1NB08147 1NB09147 7 1/2" NA NA NA NA NA 1NB06147-5 1N807147-51N808147-5 1NB09147-5 8" 1NB0115 1 N8021 1N80315 1NB0415 1NB0515 1NB0615 1N80715 1NB0815 1NB0915 8 1/2" NA NA NA NA NA 1NB0615-5 1NB0715-5 1N80815-5 1NB0915-5 9" INBOI16 1NB0216 1NB0316 1NB0416 1NB05161N60616 1NB0716 1N80816 1NB0916 9 1/2" NA NA NA NA NA 1NB0616 -5 1N80716.5 1NB0816-5 1NB0916-5 10" 1NBO117 1N80217 1NB0317 1NB0417 1NB0517 1NB0617 1NB0717 1NB0817 1NB0917 10 1/2" NA NA NA V NA NA 1NB0617-5 1NB0717-5 1N80817-5 1NB0917.5 V 1NBO118 1NB0218 1NB0318 V 1NB0418 1NB0518 V V 1NB0618 V 1NB0718 1NB0818 1NB0918 111/2" NA NA NA NA V NA 1NB0618-5 1NB0718-5 1NB0818-5 1NB0918-5 12" V 1NB0119 V 1N80219 1NB0319 V 1NB0419 VV 1NB0519 1NB0619 1NB0719 1NB0819 V 1NB0919 V LENGTH NOMINAL SIZE I FT V-27' 11 " JF-7--j F 6" J V CLOSE 1NBI001 1NB1101 V 1NB1201 1. 1NBI401 INBiOlI INBilli NA NA 31/2" 1NB1011-5 1NB1111-5 1N81211-5 NA 1NB1012 1NBI1I2 1N81212 NA V 41/2" V 1NB10I2-5 1NBI1I2-5 1NB1212-5 NA 1NBI0I3 1NBIII3 1NB1213 NA 51/2" 1NBI0I3-5 INBIII3-5 1NB1213-5 V NA 1NBIOI4 1NB1I14 1F4B1214 1NB14I4 8" 1N81015 1NBI115 1NB1215 1NB1415 91, IN81016 1N81116 1N81216 1N91416 10" 1NBI017 1N81117 1N81217 1NB1417 11' 1NB1018 INBII18 1N81218 1N81418 V 12" V INBI0I9 INRIII9 1NB1219 1N91419 www.sigmaco.com U rn'[ 0 A Allp 06 Vpplias GaN/anZ© E] Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME 81.20.1 Galvanized to spec. ASTM A 153- for zinc coating. Description [-- Galvanized Steel LENGTH it iir JI 1/4" II 3' J[ J{ 3/4" JI 1" II T T/4w I[ 172"1I I lIT' CLOSE 1NG0101 ING0201 1NG0301 1NG0401 1NG0501 1NG0601 1NGO7OI ING0801 ING090I 1" NA 1NG0201-1 NA NA NA NA NA NA NA 1 1/4" NA NA NA NA NA NA NA NA NA 11/2" ING0I08 1NG0208 1N00308 1N0408 1NG0508 NA NA NA NA 2" 1NG0109 1NG0209 1NG0309 1NG0409 1NG0509 1NG0609 1NG0709 1NG0809 NA 2 1/2" 'INGOIlO INGO2OIO ING03I0 1NG04I0 1NG05I0 1NG06I0 1NG0710 1NG0810 ING0910 3" INGOIll INGO21I 1NG0311 1NGO4I1 ING0511 ING06II 1NG0711 1NG0811 1NG09II 3 1/2" INGO1II-5 INGO2I1-5 ING03I1-5 1NG04II-5 1NG05I1-5 1NG06115 1NGO71I-5 ING0811-5 1NGO9II-5 4" 1NG0112 1Nc30212 1NG0312 1NG0412 1NG0512 1NG0612 1NG0712 1N00812 1NG0912 4 1/2" 1NG0112-5 1NG0212-5 1NG0312-5 1NG0412-5 1NG0512-5 1NG0612-5 1NG0712-5 1NG0812-5 1NG0912-5 5" 1NG0113 1NG0213 1NG0313 1NG0413 1NG0513 1NG0613 1NG0713 1N00813 1N00913 51/2" ING0113-5 1NG0213-5 1NG0313-5 1NG0413-5 1NG0513-5 1NG0613-5 1NG0713-5 1NG08135 1NG0913-5 6" ING0114 1NG0214 1NG0314 1NG0414 1NG0514 1NG0614 1NG0714 1NG0814 1N00914 6 1/2" 1NG0114-5 1NG0214-5 1NG0314-5 1NG0414-5 1NG0514-5 1NG0614-5 1NG0714-5 1NG0814-5 1NG0914.5 7" -- NA NA NA 1NG04147 NA 1NG06147 1NG07147 1NG08147 1NG09147 8" 1NG0115 1NG0215 1N60315 1NG0415 1NG0515 1NG0615 1NG0715 1NG0815 1NG0915 81/2" NA NA NA 1NG0415-5 NA NA I NA NA NA 9" 1NG0116 1NG0216 1NG0316 1NG0416 1NG0516 1N60616 1NG0716 1NG0816 1NG0916 10" ING0117 1NG0217 1NG0317 1NG0417 1NG0517 1NG0617 1NG0717 1NG0817 1NG0917 11" 1N G0118 1NG0218 1NG0318 1NG0418 1NG0518 1NG0618 1NG0718 1NG0818 1NG0918 12" 1NG0119 1NG0219 1NG0319 1NG0419 I 1NG0519 1N00619 1NG0719 1NG0819 1NG0919 LENGTH I NOMINAL SIZE L 2 1/2" J[ 3" J[ " J 6" CLOSE 1NG1001 1NGI101 1NG1201 ING140I 3" 1NG10I1 INGlIlI NA NA 31/2" 1NG1011-51NG1111-5 NA NA 4" INGI0I2 1NGI112 1NG1212 NA 41/2" 1NG1012-5 1N01112-5 INGI2I2-5 NA 5" ING1013 ING1113 1NG1213 NA 5 1/2" 1NG1013-5 ING11I3-5 1NG1213-5 NA 6" ING1014 1NG1114 1NG1214 1NG1414 7" - NA INGII14-5 NA NA 8" 1NG10I5 INGI1I5 1NG1215 1NG1415 9" ING10I6 1NG1116 - - 1NG1216 - 1NG1416 - 10" 1NG1017 1NG1117 1NG1217 1NG1417 11" 1NG1018 1NG1118 1N61218 1NG1418 IT 1NG10I9 1NG1119 INGI2I9 1NG1419 www.sigmaco.com 16 OUT COU-FLN89B O Manufactured from carbon steel (which conforms to ASTM A 865 standard) O Threads conform to ASME B1.20,1 standards for pipe threads, O Sizes 2" and below are straight tapped and 2 1/2" and above are tapper tapped. Description i Size Item Code D L 1/2" IMCC0404 1.063" 1.563" 3/4" IMCCO505 1.313" 1.625" IMCC0606 1.576" 2.00- 1 MCC0707 1.900" 2,063" 1-1/2" IMCCOBOB 2.200" 2.063" 1MCCO909 2.750" 2.125" 2-1/2" 1MCC10I0 3.250" 3.125" IMCCIII1 4.00" 3.250" IMCCI2I2 5.00" 3.500" L www.sigmaco.com victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' No. 002 Nominal Outside Size Diameter Elbows Straight Tee No. 001 No. 003 inches inches mm mm 90° Elbow 450 Elbow Branch Run 1'/4 1.660 - - - - 32 42.4 - - - - 11/2 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the 1400 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaalic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic* is a registered trademark of Victaulic Company. 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. ilctaulicr victaulic.com 3 Pipe Clamps TOLCO Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2(40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig, 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4,4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig, 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Part number and band hanger, size from 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 Approx. Wt/100 Part No. lbs. (kg) 25 4,8 (2.2) I All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 99 B-Line series Pipe -(angers & Supports Component of State of California OSHPD Approved Seismic Restraints System : 98 - Rod Stiffener Fu98B - Rod Stiffener w/Break-off Bolt Head Size RangbN Secures 3/8" thru 7/8" hanger rod Material Ca" Steel Function Sec ur.hannel to hanger rod for vertical seismic bracing Approvals - In lu a r mi R traint tia rove FIG. 98 Finish - Eloctro Galvanized Note - Available In HDG finish or Stainless materials. Order By Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 318" thru 7/8' rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Etectro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish IS Dimensions N od Max. Rec. Load Lbs. For Service Temp 3/8 '. 730 1/2 . 1350 5/8 %2160 3/4 7/8 Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750"F Finish - Plain Note - Available in Etectro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 - All Thread Rod Full Lnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F W000 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1½ 13800 510 OFFICEIMANUFATURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.7375599 • FAX: 951.737.5330 CUSTOMER SERVICE • 900,7K5266 www.tolco.com Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - /8"-16 to I411 -10 rods Component of State of California OSHPD Approved Fig. 980H - Universal Swivel Sway Brace Attachment - 7/11_9 to 11/411-7 rods Seismic Restraints System Size Range: One size fits bracing pipe 1 "(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections, NFPA 13 (2010) 9.3.5,8.4 Indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It Is intended to be combined with the "bracing pipe" and TOLCO "braced pipe' attachment, Fig. 1000, 1001, 2002, 4L, 4A or 48 to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set screw until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. 771 K 9@ U3 <~> liSTED Set Screw Included Mounting Hardware Is Not Included Note: Fig. 980 Swivel Attachment and Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 4B or Fig. 4L pipe clamps make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. US Patent Numbers Pat. #6,273,372, Pat. #6,517,030, Pat #6,953,174, Pat. #6,708,930, Pat #7,191,987, Pat #7,441,730, Pat #7,669,806 Mounting attachment hole size. " Installed with 1" or 11W Schedule 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assombiy. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, In addition to the other exclusions from B-Line's warranty, Eaton's B-lire Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are In millimeters unless otherwise specified. Pipe Hangers & Supports 182 B-Line by 9.11410 C@1113 <j3> IJ3TEU Set Scre In' TOLCOTM Seismic Bracing Fig. 41 - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2' (50mm) through 8' (200mm) lPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed In the USA (UL) and Canada (cUL) 21/2" (65mm) through 8" (200mm) pipe. Approved by Factory Mutual Engineering (FM), 2' (50mm) through 8" (200mm) pipe. Installation Instructions: Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 41 over the pipe to be braced and tighten bolts. Then engage 'bracing pipe' into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain, Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. 4- W(plan view) ay Riser Brace Li '-j Longitudinal Brace Part Pipe Size A C D Bolt Size Max. Rec. 2015 (cULuc) H8.96( Load •Approx. (1`11) 'H Vit./i 00 242.0) 41_21/2 2/2" (65) 611" (1635) 21/2" (635) 2/4' (69.8) 1/2"_13 2015 (8.96) 3000 (13.34) 253 (114.7) 41-3 (80) 7" (177.8) 2/4" (69.8) 31/16" (77.8) 1/211_13 2015 (8.96) 1550 (6.89) 268 (121,5) 41-4 (100) 81/2" (215.9) 3/8" (85.7) 311/16" (937) 1/2"13 2015 (8.96) 1550 (6.89) 348 (157.8) 4L-5 5' (125) 93/4' (247.6) 3I8" (98.4) 1) 112",.13 2015 (8.96) 1450 (6.45) 380 (172.3) 41-6 (150) 111/2" (292.1) (127.0) 43/'L (I 51/8"2) 1/2"_13 2015 (8.96) 1450 (6.45) 640 (290.3) 41-8 8' (200) 131/4" (336.5) 5I8" (142.8) 55/'9) h/2"_13 2015 (8.96) 1450 (6.45) 728 (330.2) Part 4L-2 2 Pipe Size (50) Max. Rec. Load (cULuc) 2015(8-96) . - I *Max. Design L I -. -- 4L-21/2 21/2" (65) 2015 (8.96) 1030 (4.58) 1180(5.24) 1420 (6.31) 1590 (7.07) 41-3 (80) 2015(8.96) 1030(4.58) 1180(5,24) 1420(6.31) 1590(7.07) 4L-4 (100) 2015(8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-5 (125) 2015(a.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-6 1 6' (150) 1 2015 (8.96) 530(2.36) 730 (3.25) 1 890 (3.96) 990 (4.40) 41-8 1 8" (200) 1 2015(8.96) 490 (2.18) 680(3.02) 1 830(3.69) 930 (4.13) * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 11/4', 114" or 2" Sch. 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting In a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business, All dimensions In charts and on drawings are In Inches. Dimensions shown In parentheses are In millimeters unless otherwise specified. Pipe Hangers & Supports B-Line by 17.174VII Seismic _Bracing TOLCO Fig. 1001 - Sway Brace Attachment Component of State of California QSHPD Approved Size Range: Pipe size to be braced: 1" 25mm1 thru 8" (200mm) I PS. Seismic Restraints System Pipe size used for bracing: 1" 2mmi and 11/4' (32mm) Schedule 40 IPS, Material: Steel Function: For bracing pipe against sway and seismic disturbance, LISTED The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS, Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way g riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Set Screws W. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten Included two hex head cone point set screws until heads bottom out. A minimum of 2. 120 1' (2mm) pipe extension is recommended, Brace pipe can be installed on top or Pipe Max, Horizontal Design Load (UL) Lbs, bottom of pipe to be braced. Size For Brace Pipe Size 1"/ 11/4" Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Sch. 7 Sch, 10 Sch. 40 Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints in. (mm) 1" I 1/4" 1"/ 11 /4" 1"/ 1/4" Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement /- (25) -. 1000/1000 1000/1000 information relating to OSHPD projects, please refer to the TOLCO Seismic 11/4" 1321 1000/1000 1000/1000 1000 /1000 Restraint Systems Guidelines, OPA-030010. 11/2" (40) 1000/1000 1500/1500 1500/1500 Finish: Plain or Electro-Galvanized. Contact customer service for alternative 1501 1000/1000 2015/2015 2015/2015 finishes and materials. Order By: Indicate pipe size to be braced followed by pipe size used for bracing, 21/2" (55) 1600/1600 2015/2765 2015/2765 figure number and finish. 3" (80) 1600/1600 2015/2765 2015/2765 Important Note: Fig. 1001 is precision manufactured to perform its function as 'i" 11001 1600/1600 2015/2765 2015/2765 a critical component of a complete bracing assembly. To ensure performance, the 6" (150) 1600 /1600 2015/2765 2015/2765 UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing 8" (200) 1600 /1600 2015 /2765 2015/2765 products. Pipe Size in. (mm) Part Number & Approx. Wt/100 1" 124mm) Brace Pipe 11/4" 132mm) Brace Pipe Lbs. (kg) I Lbs. (kg) 300.440 Lbs. NN) Max. Horizontal Design Load (FM) For Sch. 7, Sch. 10, & Sch. 40 Pipe 1.Z3 450.590 590.740 Lbs. (kN) Lbs. NN) 750.90 Lbs. (kN) (25) 1001-1 X 100.0 145.31 1001-1 X1'/4 118.0 (53.5) 1800 (8.00) 2550 111.341 3120 (13.88) 3490 (25.52) 11/4" (32) 1001-1'/4 X 100,0 (45.3) 1001-1/4 X 11/4 114.0 (51,7) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 11/2" (40) 1001-11/2 X1 100.0 (45.3) 1001-11/2 X 11/4 115.0 (52.1) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10,58) (50) 1001-2X1 108.0 (49.0) 1001-2X11/4 121.0 (54.9) 1230 (5.47) 1740 (1.74) 2140 (9.52) 2380 (10.58) 21/2" 1651 1001-21k X 138.6 (62.8) 1001-2'/z X 11/4 160.4 (72.7) 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 (6.85) (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 160.9 (73.0) 1001-4 X 1 /4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.28) 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98.6) 1 1001-8 X 1114 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 1114 inch NPS Schedule 40 GBIT 3091, EN 10255H, or .J)S G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/7 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GBIT 3092, EN 10255M and H, or JIS 03454, FM Approved Thinwaf, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 13-Line series Pipe Hangers & Supports SAMMYS® FOR WOOD j No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver, Saves time from traditional methods, Reduces installation costs Manufactured in the liSA a *1 drnnstration a7 \/vwøwMwbuIWex.comJ 1(4w 8002957 GST 100 1/4x1" 210 (7/16QSB) 25 125 & 1,4 8003957 GST 200 1/4x2 1760 (Fir) 25 125 QL 3ir 8007957 GST 10 1/4 xl 210 (7116- CISB) 300 25 125 670 3/8 8008957 GST 2O 114x2 1760 r6) -- 850 1475 25 125 W 8068925 GST 20-SS 1/4 x 2 - 1760 (Fir) 850 25 125 #14 Black Tir 8009925 GST 25-380 318x2.117 2113 (Fir) - 1500 25 125 MJtDiver <' air 8010957 GST 30 1/4x3 - 2060 (Fir) 1500 - - 1475 25 125 Pat18113910 - 3/9 •8069925 GST _3(-SS 114x3 - 206 (Fir) - 25 125 1/7 8013925 GST2 114x2 1760 (Fir) 25 125 1 8015925 GST3 - 1/4x3 2275 (Fir) - 25 125 #14 SW Red ft*4D P&4*8114910 A, vl'~— cMuu SI 5PEC8*t*UTORIVa he nutdrivers wart dsigrrewith a unique sroff feature which provides a fast and safe installation each time, When the face of the driver comes into con1chwth the materiel you are aIflh Frito, continue orliling until nut driver spins free, Installation is then complete. Warranty requires the use of the appropriate nut driver for installations, I kb MMYS No pro-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless 7ftorjoliltj drill/driver. Saves time from traditional methods. Reduces installation costs, ______ Manufactured in the U.S.A. Not less then nomlnelwidth (1i/?4o37ppnouInathen Y (2a1/2°) nominal wl4ti 4' & 5' pipe I minimum2AWIlromboilornfor bcanth rines nlmum 3° from bct ocn for main meL Epton;This reqamenI ahall net apply iD 2°or thicker noting atn$ resting on top of ateet beams, ftth a www ltw videQ dbulldexn,ors1iation t .corn T 1(4° 8019957 SWG 200 I 3/5' 8020957 SWG 10 3/V 8021957 SWG 20 3/8' 8073925 SWG O-SS 1L. - 3I&' 8022925 - SWG 25-380 - 1145WRed 3/8' - 8023925 SWG 30 Pat t81I4910 M$yre tjoiutmanuturer, 1/4x2 1725 (Fir) 25 125 1/4 xl' 622 (Fir) 300 25 125 1/4*2' 1725 (Fir) 1050 25 125 1/4k 2° 1725 (Fir) 850 25 125 3/8* 21/2° 2249 (-Fir) -. 1500 25 125 1/4 x 3' 1884 (Ffr) - - - 25 125 - Eliminates distortion of threaded rod, 'Accommodates up to 3 1h" x 12 pitch roof. Allows 17° deflection from vertical, Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. F.s 1491ack NvtDnfver I/> 3/V 5139957 SH-GST20 1/4*2° 1257 (Fir) 1050 1475 25 125 Part#81139i0 r - - - 1903 Dim. Lumber ir 8269957 SH-GST/CST2O 5/16*1-3/4" 1500 140645°offvertical 25 125 Dim. Lumber 903 Dim, Lumber 1~'14!' 1/2' 8303957 SN-GSTICST2,0 5/16*1-3/4 140645°off vertical 25 125 Dim, Lumber May require pre-drilling; consult joist manufacturer. 1I4EHOra,a 10 PaI152739I0 iACCESSORIES Pre-drill a hole with a regular drill or hole saw, I SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3, When bolt is secure and nut driver spins free, stop drill motor and remove. 4. SST screw is now ready to receive 1/4", 3/8", or Metric all thread red or bolt stock. Hollow Corn Concrete ll4 8063925 SST 300 1/4*3" 450 (Lath & Plaster) 25 125 Ultimate1IFOTTIWD $TI•hr Case Qty 404 (2 Layers 5/8 Rock) 3I8 8064925 S 30 1/4*3' 450 (Lath & Plaster) 25 125 #14 Black 404 (2 Layers 5/8 Rock) Nut Driver Part 4 8113910 Number Length VApprovals c.. STEEL 8107957 CWSD 1* Teks 1/4 xl" - ICC STEEL 8190957 CWSD 15" Get 114x1.1/2" - 23/4" WOOO Teks ICC - STEEL 8108957 CWSD 2" Teks 1/4x2" 3-1/4" CWIT IC 8110910 CNIT Installation Tool lestaliabon Tool Pa."t# 8110910 3/16" eyelet to accommodate common wire size. ICC approvals can be found at www.ltwbuIldea.com under Evaluation Report # ER-5367. 472 (20ga) 16 9a 170 (?0 91.1 125 3r 209a. 170 (209a,) 25 125 472 (20ga) - 169a. - 170 (20 ga4 25 125 Does not comply with FtOHS requirnmento WE 'Does nor comply with P/OHS requirements / Includes ratalningnut MYS Made with Te15*self.dIling fasteners no pre.dlling required. Installs Into steel range from 20 gauge - 1/2" thicknesses, A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 04500. 'Saves time from traditional methods. Reduces Installation costs. Quick to Install using the Sammys Nut Driver with an iSV cordless drill/driver, a/\ Manufactured In the USA. wwvJ1wbuiWex.comJ _I9.. 114' 8047957 SW 10O 1(414x1"TEKS3 1477 (l6 go.) 080.1826 3/16' 25 125 1/4 8049957 SWOR 100 1/420 s I TEKS 3 1900 (20 ga) .636.20 9s 3/16" 25 125 3/6" 8050957 SWDIO 1/4.44x17EKS3 1477 (16ga.) 060.164 3/16" 25 125 3/8" 8080925 SWD 10-SS 1/4.14 x TEKS 3 1477 (16 ga.) .060"'16ga 3/16' 25 125 3/8 8052957 5W020 1/414x2 TEKS3 1477 (16ga) - .060"-16 ga 3/16 25 125 IF 8055957 SWDR 1 1/420 xl TEKS 3 1900 (20 ga) 1500 1475 .036%20 ga 3/16 25 125 #I4SWRed .' 3/8" 8054957 SWDRI-1/2 12-24x1.1/2TEKS5 2375 (3/16") 1500 1475 .188"3/16" 1/2" 25 125 MA Mm 3/6" 8056957 SW-DR 5I6" 5/16-18x 1-114TEKS3 2480 (20ga.) 1500 1475 .036"-209a 3/16" 25 125 Pt#81149I0 - 3/6" 8057957 SWTI5 12-24x1-1/2"TEKS5 2375(3/16") - .188"-3/16" 1/2" 25 - 125 *include retaining nut B Overall Height For 1/4 Flat Head Machine Screws or Wood Screws Upper Attachments B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated Size Range: 3/a'-i 6 & 1/2"13 rod Material: Malleable Iron (Stainless Steel Typo 304 available) Standard Finish: Plain or Electro-Galvanized B3199RCT is DURA-COPPERTM coated Function: Designed for attaching a hanger or support rod to beams, ceilings, or walls, Order By: Part number and finish. "-A (Rod or Pipe Thread) Hanger Rod or Pipe Not Included Part No. Thread Size B Design Load Approx. WtI100 A In. (mm) Lbs. (kN) Lbs. (kill 03199R-3/8 B3199RCT- fa'-16 l/m (11.1) 180 (80) 13 (5.9) B3199R-1/2 B3199RCT-1/2 1/2'_13 1/2' (12.1) 180 (.80) 11 (1.1) TOLCO Fig. 78 - All Steel Ceiling Plate Size Range: /a'-16 rod Material: Pre-Galvanized Steel Function: Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, UL has listed the Fig. 78 with fasteners as shown in the table below. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number, rod size and finish US Patent #5,702,077 LTED UI. Listed Fastener Table Pipe Size Wy I Fastener Type Material 1/2'. 2 2 #14x 11/4' A-point hex-washer-head sheet metal screw Wood 21/2' - 4' 2 IXx 11/2" wood screws* Wood 1/2' - 2' 2 1/4' x 1" tek screws Metal (18 gauge) 1/2" - 2' 1 2 1#14 x 11/4 A-point hex-washer-head sheet metal screw Wood 1/2' 2' 2 #14x 2' A-point-hex-washer-head sheet metal screw ' Wood thru /a' gyp board * No pro-drilling Part No. Pipe Size A B C Hole Dia. D Thread Size Design Load Approx. Wt./100 In, (mm) in. (mm) in. (mm) in. 1mm) in. (mm) E Lbs. (kN) Lbs. (kg) 78-/ 1/2"-2" (15-60) 3' (16.2) 21/8" (54.0) V/a' (28.6) fi' (1,9) /8"-16 150 (0.57) 15 (6.8) Consult Factory For Data All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 216 Eaton Victaulic® FireLock NXTTM Preaction Trim JtauIia Series 769N 31.82 Patented 1.0 PRODUCT DESCRIPTION Available Sizes 1 ½— 8"/DN40 - DN200 Pressure Class Up to 300 psi/2068kPa/21 bar Minimum Air Pressure 13 psi/90 kPa/.90 bar Acutation Options Series 776 Low Pressure Actuator Series 767 Electric/Pneumatic Actuator Series 798 Double-Pneumatic Actuator Electric Release 24V DC Normally closed solenoid Release Mechanism Non-Interlocked Single Interlocked Double Interlocked Valve Configurations Bare Pre-trimmed Vic-Quick Riser: Pre-trimmed and includes: Shut Off Valve (1 ½'/DN40: Series 728 Ball Valve, 2' - 87DN50 - DN200: Series 705 FireLockT' Butterfly Valve) Pre-set alarm pressure switch Pre-set high or low air pressure switch (Dry Pilot Only) Drain Connection kit Fire-Pac Series 745 (refer to Victaulic publication 30.23) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT, System No, Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 31,82 9999 Rev B updated 02/2019 © 2019 VictauUc Company. All rights reserved. ',J(ctauIic' 1 __________________ victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Application: For use on fire protection systems only 2.0 CERTIFICATION/LISTINGS 1LPCB ® tQ41a/O2 3.0 SPECIFICATIONS - MATERIAL Body: Ductile iron conforming to ASTM A536, Grade 6545-12, Clapper; Aluminum bronze Latch: Aluminum bronze Shafts: Stainless 174 Clapper Seal: Peroxide cured EPDM Bushings/Seat 0-rings: Nitrile Springs: Stainless steel Diaphragm: Peroxide cured EPDM with fabric reinforcement The 1½/DN40 and 2/DN50 valve sizes contain washers under the heads of the cover plate bolts. Item Description Valve Body 2 Clapper 3 Clapper Seal 4 Seal Ring 5 Seal Washer 6 Seal Retaining Ring 7 Seal Assembly Bolt 8 Clapper Spring 9 Clapper Shaft 10 Clapper Shaft Bushing and 0-Ring (Qty. 2) Item Description 11 Cover Plate 12 Cover Plate Gasket 13 Cover Plate Bolts 14 Latch 15 Latch Spring 16 Latch Spring Bushing and 0Rlng (Qty. 2) 17 Diaphragm 18 Diaphragm Cover 19 Diaphragm Cover Cap Screws (Qty. 8) 20 Latch Shaft 31.82 9999 Rev B Updated 02/2019 C 2019 Victaulic Company. All rights reserved. victaulic.com 2 jttaukcr victaulic.com 0- 3.0 SPECIFICATIONS - MATERIAL (Continued) O Standard Trim Package: Non-Interlocked Pneumatic Release: The pneumatic release system uses a supervisory pilot line to detect a release event. When EITHER a pilot sprinkler or a system sprinkler operates, the water in the diaphragm chamber is released and the valve operates, Pneumatic/Electric Release: The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. The valve operates when the water in the diaphragm chamber is released when Either 8n electric detection or a system sprinkler operates. Single Interlocked Electric Release: The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. The valve operates when the water in the diaphragm chamber is released when a release system event occurs. Pneumatic Release: The pneumatic release system uses a supervisory pilot line to detect a release event. Only when a pilot sprinkler operates will the water in the diaphragm chamber be released and the valve operate. Double Interlocked Electric Release: The electric/pneumatic/electric release uses two electric detection devices, a fire detection device and a low pressure switch installed in the sprinkler system. The valve will actuate ONLY when BOTH a fire detection event and loss of system pressure occurs. Pneumatic/Electric Release: The pneumatic/electric preaction system uses both a pneumatically pressurized sprinkler system, and an electric release system, (composed of an approved solenoid valve, electric panel and an appropriate sensor). The valve will activate ONLY when there is a pressure loss in the sprinkler system AND the electric detection of a release event. Pneumatic/Pneumatic: The pneumatic/pneumatic system uses one Series 798 Double Pneumatic Actuator to control the Series 769N Actuated Valve. The valve will operate ONLY when there are sprinklers activated in both the pilot line and the sprinkler system. All required pipe nipples and fittings - standard galvanized finish All standard trim accessories All required gauges Series 755 Manual Release Panel o Optional Trim Package: Black Trim for Foam Systems - If the valve is intended for use in a foam system, black trim must be ordered, per NFPA requirements, Specify this requirement on the order. 31.82 9999 Rev B Updated 02/2019 0 2019 Victaulic Company. All rights reserved. victaulic.com 3 \taulic? victaulic.com 3.0 SPECIFICATIONS - MATERIAL (Continued) Optional Accessories: O Alarm Pressure Switch - Alarm pressure switches activate electrical alarms at the control panel when the 769N valve actuates and flows water into the system piping, (Note: an open sprinkler may not actuate a 769N valve but any low air alarms should operate.) Air Supervisory Pressure Switch - Air Pressure Supervisory Switches are used to monitor low and high system air pressure and are factory pre-set. O Series 746-LPA Dry Accelerator - The Series 746-LPA Dry Accelerator is required when the Series 769N Preaction trim is installed in large systems to improve response time. Refer to Victaulic publication 30.64. Series 760 Water Motor Alarm - The Series 760 Water Motor Alarm is a mechanical device that sounds when the 769N valve actuates and is filling the system and discharging any water through any open sprinklers. Refer to Victaulic publication 30.32. O Series 75B Supplemental Alarm Device - The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Refer to Victaulic oublication 30.33. O Series 75D Water Column Kit - The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Refer to Victaulic gublication 30.34. AutoConvert Kit - The AutoConvert Kit includes the Series 776 Low Pressure Actuator, latching solenoid, strainer, 3-in-I strainer/check/restrictor assembly, air pressure gauge and assembly trim. It is ordered separately and can be installed on any FireLock NXTM Single Interlock or Double Interlock Preaction system that includes a solenoid. O Air Supply System - The air supply system contains all components for establishing and maintaining air in the system. The compressor ball valves, and required trim are included in the air supply system. Air Compressor Refer to Victaulic publication 30,22. O Air Maintenance Trim Assembly Refer to Victaulic publication 30.35. Fire Alarm Control Panels Drain Connection Kit Redundant Electric Solenoid made by alternate manufacturer required by LPCB approval. Orangeohadedaraao identity ,omportee,s that are optimal equipment.Th.se component, are standard when the VQR assembly iaordered. Gray shaded areas Identify components that ate optional equipment. H if 31.82 9999 Rev B updated 02/2019 0 2019 Victaulic Company. All rights reserved. victaulic.com 4 j,i(ctauiic victaulic.com 4.0 DIMENSIONS A 4/DN100 valve with single-interlocked pneumatic release preaction trim is shown below 1 ½ - 27DN40 - DN50 configurations contain 3/4 /19 mm drain valves 2½ - 3"/DN65 - DNBO and 73,0 mm configurations contain 11/4731 mm drain valves 4- 8/DN100 - DN200 configurations contain 2750 mm drain valves Full Open Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A5 Al2 B5 C D4 D14 E F G H K Trim Trim Inches Inches inches Inches inches inches inches Inches inches inches Inches Inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1,900 9.00 16.37 34,25i9,25 1 16.25 11.00 9.00 3,25 10.25 24,00 6.00 16.7'43.0 DN40 4813 229 416 870 235 413 279 229 83 260 610 152 7.6 19.5 2 2.375 9.00 13.83 34.25 9.251 17.50 11.00 9.00 3.25 10.25 24.00 6.00 17.0 43.0 DN5O 603 229 351 870 235 445 279 229 83 260 610 152 7719.5 21/2 2.87512.61.16,51 35.7511.2520.0012.50•9.50.4.00 9.75 26.00 6,50 41065.0 73.0 320 419 908 286 508 318 241 102 248 660 165 18,7 29.5 3.000 12.61 1 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6,50 41.0 65.0 DN65 76.1 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 3 3.500 12.61 16.51 35.75 11.25 20.00 12.50 9,50 4.00 9.75 1 26.00 6.50 41.0 65.0 DN80 88.9 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 4 4.500 15.03 19.85 36.50 1330 22.25 13.50 11.00 4.75 8.50 28.00 1ioo 59.0 95.0 DN100 114.3 382 504 927 343 565 343 279 121 j 216 711 203 26.7 43.0 6.500 16.00 22.13 36.75 14.00 . 24.50 13.25 11.00 450 8.25 28.50 8.25 80.0 116.0 165.1 406 562 933 356 622 337 279 114 210 724 210 36.2 52.6 6 6.625 16.00 22,13 36.75 14.00 24.50t 13.25 11.00 4.50 8.25 2830 8.25 80.0 116.0 0N150 168.3 406 562 933 356 622 337 279 114 210 724 210 L 36.2 52.6 8 8.625 17.50 23,02 39.50 14.75 27.00 13.50 12.25 4.75 8.25 31.25 9.25 122.0 . 158.0 DN200 219.1 445 585 1003 375 686 343 311 121 , 210 794 235 553 71.6 The "A' dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with the optional Series 746-LPA Dry Accelerator, add 11.50 inches1292 mm to the "B" dimension to account for the additional height. The "D" and "Dl" dimensions are not fixed measurements. The drip cup can be rotated to provide more clearance at the back of the trim. NOTES The drawings shown above reflect the single-interlocked pneumatic release trim with Series 776 Low-Pressure Actuator. In addition, these dimensions can be applied to all other trim configurations featured within this manual, Components shown as dotted Ivies denote optional equipment, The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered, 31.82 9999 Rev B Updated 02/2019 C 2019 Victaulic Company. All rights reserved. victaulic.com 5 Wt Al-c-taulicr victaulic.com 4.1 DIMENSIONS A 47DN100 valve with electric autoconvert dry release preaction trim is shown below 1½ - 2'7DN40 - DNSO configurations contain 3/4719 mm drain valves 2½ - 3'/DN65 - DN80 and 73.0 mm configurations contain 11/4"/31 mm drain valves 4 - 87DN100 - DN200 configurations contain 2750 mm drain valves Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 03 C D Dl E F G H K Trim Trim inches inches Inches inches Inches Inches inches Inches inches Inches Inches Inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1,900 9.00 16,37 38.00 15.5025.0016.259.503,2510,2527,756,00 16.7 43.0 DM40 48.3 229 416 965 394 635 413 241 83 260 1 705 152 7.6 19.5 2 2.375 9,00 13.83 38,00 15.50 25.00 16.25 9.50 325 10.25 27.75 6.00 17.0 43.0 DN5O 60.3 229 351 965 394 635 413 241 83 260 705 152 7.7 19.5 2½ 2.875 12,61 1651 40.75 16.00 24,00 15.00 950.4.009.75 31,006.50 41,065.0 73.0 320 419 1035 406 610 381 241 102 248 787 165 18.7 . 29.5 3.000 12.61 16.51 40.75 16.00 24.00 15.00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 DN65 76.1 1 320 j 419 1035 406 610 381 241 102 248 787 1- 18.7 293 3 3.500 12,61 16.51 40.75 16.00 24.00 15.00 9,50 4.00 9.75 31.00 6.50 41,0 65.0 DN80 88.9 320 419 1035 406 610 381 241 102 248 787 165 18.7 29.5 4 4.500 15.03 19.85 42,50 15.25 22.50 14.75 11,00 4.75 8.50 34.00 7.50 59.0 95.0 DM100 114.3 382 504 1080 J 387 572 375 279 121 216 864 191 26,7 43.0 6.500 16.00 22.13 42.50 15.25 26.00 15.25 11.00 4.50 8.25 I 34.25 8.25 80.0 I 116.0 165.1 406 562 1080 387 660 387 279 . 114 210 870 210 36,2 52.6 6 6.625 16.00 22.13 42.50 15.25 J 26.00 1 15.25 11.00 4.50 8.25 f 34.25 8.25 80.0 116.0 DM150 168.3 406 562 1080 387 660 387 279 114 210 870 210 36.2 52.6 8 8.625 17.50 23.02 44.50 18.50 30.00 16.00 12.25 4.75 8.25 36.25 925 122.0 158.0 DN200 219,1 445 585 1130 470 762 406 311 121 210 921 235 55.3 71.6 The 'A" dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with the optional Series 746-LPA Ory Accelerator, add 9.50 inches/241 mm to the 'B" dimension to account for the additional height. NOTES The drawings shown above reflect the electric AutoConvert dry release trim, In addition, these dimensions can be applied to the redundant solenoid valve configuration, Components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comas standard when the VUR assembly is ordered, 31.82 9999 Rev B Updated 02/2019 0 2019 Victaulic Company. All rights reserved. victaulic.com 6 'j(ctauhcr victaulic.com 4.2 DIMENSIONS A 4/ON 100 valve with double-interlocked electric/pneumatic autoconvert dry release preaction trim is shown below 1½ - 2'IDN40 - DN50 configurations contain 3%/19mm drain valves 2½ - 3/DN65 - 0N80 and 73,0 mm configurations contain 11/4'731 mm drain valves 4 - 87DN100 - DN200 configurations contain 2/50mm drain valves Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A1 Al2 B3 C 0 Dl E F G H K Trim Thm inches Inches inches Inches inches inches inches Inches Inches inches inches Inches Inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1.900 9,0016,37136,5017.50.20.25'13.509,00 325 10.25 26256.00 16.7 '43.0 DN40 48.3 229 416 927 445 514 343 229 83 260 667 152 7.6 19.5 2 2.375 9.00 13.83 36.50 17.50 20.25 13.50 f 9,00 3.25 10,25 26.25 6.00 17.0 43.0 DN5O 60.3 j 229 J 351 927 445 514 343 j 229 83 260 667 152 7.7 19.5 21/2 2.875 12.61 16,51 38.25 17,50 20.75 13.50 9,50 4,00 9.75 1 28.50 6,50 41,0 65.0 73,0 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 3.000 12.61 j 16.51 38.25 17.50 20.75 13.50 9.50 4.00 9.75 28.50 650 41.0 65.0 0N65 76.1 320 419 972 445 527 343 241 102 248 72 .._4 165 18.7 295 3 3.500 12.61 16.51 38.25 17,50 20.75 13.50 950 4.00 9.75 28,50 . 6.50 41,0 65.0 DN80 88.9 320 419 972 445 527 343 241 102 248 I 724 165 18,7 29.5 4 4.500 15.03 19,85 39.00 14.25 2025 12,50 11.00 475 1 8.50 30.50 7.50 59.0 95.0 DN100 114.3 382 504 991 362 514 318 279 12.1 216 775 j 191 26.7 43.0 6.500 16.00 22.13 40,25 15.00 20.75 13.00 11.00 4.50 8.50 31.75 825 80.0 116.0 165,1 406 562 1022 381 j 527 330 279 114 216 806 210 36.2 52.6 6 6.625 16.00 22,13 40.25 15.00 20.75 13.00 11.00 450 8.50 31.75 8,25 80.0 116.0 DM150 168.3 406 562 L1022 381 527 330 279 j 114 216 806 210 36.2 52.6 8 8.625 17.50 23.02 41.75 16.00 21.50 13.50 1225 4,75 8.25 33.50 9.25 122,0 158.0 DN200 219,1 445 585 1060 406 546 , 343 311 121 210 851 235 553 71.6 The A" dimension is the actual takeout dimension of the valve body. 2 The "Al' dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with the optional Series 746-LPA Dry Accelerator, add 9,50 inches/241 mm to the '9" dimension to account for the additional height NOTES The drawings shown above reflect the electric AutoConvert dry release trim. In addition, these dimensions can be applied to the redundant solenoid valve configuration. Components shown as dotted tines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. I 31.82 9999 Rev B Updated 02/2019 C 2019 Victaulic Company. All rights reserved. victaulic.com 7 '%14tautic? victaulic.com S.. 4.3 DIMENSIONS A 47DN 100 valve with double-interlocked pneumatic/pneumatic release preaction trim is shown below 1½- 2/DN40 - DN50 configurations contain 3/4719 mm drain valves 2½ - 3/DN65 - DNBO and 73.0 mm configurations contain 11/031 mm drain valves 4 - 8/DN100 - DN200 configurations contain 2750 mm drain valves Full Open Size Dimensions Weight Each Actual Outside Without With Nominal Diameter At Al2 B3 C D D14 D24 E F G H K Trim Trim inches Inches inches inches inches inches inches Inches inches Inches Inches inches inches inches lb lb ON mm mm mm mm mm mm mm mm mm mm mm mm mm kg kg 1½ 1.900 9,00 16.3736,0091521.2511.00 23.50 9.25 3.25 10.25 25.75 6.00 16.7 43.0 0N40 48.3 229 416 914 235 540 279 597 235 83 260 654 152 7.6 19.5 2 2.375 9,00 13.83 36.00 9.25 21.25 11.00 23.50 1025 25,75 6,00 17.0 43.0 0N50 60.3 229 351 914 235 540 279 597 9.25E3,25 235 260 654 -j 152 7.7 19.5 214 2.875 12.61 16.51 37,75 11.25 22.50 12,50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 73.0 320 419 959 . 286 572 318 629 241 102 248 711 165 18.7 29.5 3.000 12.61 16.51 37.75 1125 2250 1250 24.75 9.50 j 4.00 1 9.75 28.00 630 41.0 65.0 DM65 76.1 320 419 959 286 572 318 629 241 102 248 711 165 18.7 293 3 3.500 12.61 16.51 37.75 11,25 22.50 12.50 24,75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 DN80 88.9 320 419 959 286 572 318 629 241 102 248 711 165 18.7 29.5 4 4.500 15.03 19.85 38.50 1330 23.75 13,50 2625 10.00 4.75 j 8.50 30.00 8.00 59.0 111.0 DM100 j_4.3 382 504 978 343 603 343 667 254 121 j 2164_ 762 203 26.7 50.3 6.500 16.00 22.13 39.25 14,00 24,50 13,25 27.75 11.00 4.50 8.25 31.00 825 80.0 132.0 165.1 406 562 997 356 622 337 705 279 114 210 787 210 36.2 59.8 6 6.625 16.00 22.13 39.25 14.00 24.50 1325 27.75 11.00 430 825 31.00 825 80.0 132,0 DM150 168.3 406 562 997 356 622 337 705 279 114 210 787 210 362 59.8 8 8.625 17,50 23.02 41.25 14.75 27,00 1330 29.75 12.25 4,75 825 33.00 925 122.0 174.0 , DN200 219,1 445 585 1048 , 375 , 686 343 756 311 121 210 838 235 55,3 78.9 The 'A' dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with optional Series 746-LPA Dry Accelerators, add 11.50 inches/292 mm to the "8" dimension to account for the additional height. The "D" and "Dl" dimensions are not fixed measurements. The drip cup can be rotated to provide more clearance at the back of the trim. NOTES Components shown as dotted lines denote optional equipment. The recommended draw connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VOR assembly is ordered, 31.82 9999 Rev B Updated 02/2019 C 2019 Victaulic Company. All rights reserved. S \/tauIicr victaulic.com victaulic.com 5.0 PERFORMANCE Hydraulic Friction Loss The chart below expresses the flow of water at 65"F/18'C through an open valve. 4.0 30 ell L0 0.9 0.8 I LU 07 0.6 0.5 0,4 0,3 0.2 OIL I J111J1i ..LJ.it1IIJ1 I I 1itHJ j 10 20 30 40 60 80100 200 300 400 600 1,000 2.000 4,000 6,000 10,000 20,000 800 3.000 81000 FLOW RATE - GPM Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 769N FireLock NXTM, Preaction Trim in equivalent feet of straight pipe. Size Equivalent Actual Nominal Outside Diameter Length of Pipe Inches inches feet DN mm meters 11/2 1.900 3.00 DN40 483 0.914 2 2.375 9.00 DN50 60.3 2.743 2½ 2.875 ' 8.00 73.0 2.438 3.000 8.00 DM65 76.1 2.439 3 3.500 ' 17.00 DN80 88.9 5.182 4 4.500 21.00 DM100 114.3 6.401 6.500 22.00 165.1 6.706 6 6.625 22.00 DN150 168.3 6.706 8 8,625 50.00 DM200 219.1 15.240 Flow Coefficet Cv Values: Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. Formulas for Cv values Where Q2/C'12 QCvx½P orFlw C Size Full Open Actual Outside Nominal Diameter Flow Coefficient inches inches ON _mm K, 1½ 1,900 60 - DN40 48.3 52.0 2 2.375 110 0N50 _60.3 95.0 2½ 2.875 180 73,0 156.0 3.000 180 DM65 j 76.1 156.0 3 3.500 200 DM80 88.9 173.0 4 4.500 350 DN100 114,3 302.8 6.500 1000 165,1 865.0 6 6.625 1000 DM1 50 168.3 865.0 8.625 1500 DN200 1 219.1 1297,5 101 PM AP (Pressure Drop) psi 31.82 9999 Rev B Updated 02/2019 2019 Victvulic Company, All rights reserved. victaulic.com JctauIicr victaulic.com 5.0 PERFORMANCE (Continued) Air Supply Requirements Minimum; 13 psi/90 kPal.9 bar regardless of the system water pressure Maximum Recommended: 18 psi/124 kPa/124 bar Sizing the compressor; Engineer/system designer is responsible Entire system must be charged to the required air pressure within 30 minutes to meet NFPA requirements An oversized compressor will slow down or possibly prevent valve operation Compressor filling the system too fast: May be necessary to restrict the air supply Ensure that air exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is exhausted Compressor Requirements Base or Riser Mounted Compressors; "On" or "low" pressure setting; 13 psi/90 kPa/,9 bar "Off" or "high" pressure setting; 18 psi/124 kPa/1,24 bar Victaulic Series 7C7 riser mounted and pre-set for pressure requirements (refer to Victaulic publication 30.22). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with pressure switch should be installed (refer to Victaulic publication 30.36). Shop Air or Tank-Mounted Air Compressors; Series 757 Regulated Air Maintenance Trim Assembly should be installed (refer to Victaulic publication 30.35) 13 psi/90 kPa/.9 bar should be used as the set point for the air regulator The compressor cut-in (turn-on) pressure setting should be at least 5 psi/34kPa/34 bar above the set point of the air regulator. Exploded View Trim: Series 757 Regulated Air Maintenance Trim Assembly (refer to Victaulic publication 30.35) Compressor Requirements and settings for systems installed with Series 746 or Series 746-LPA dry accelerators A tank-mounted air compressor with a Series 757 Regulated AMTA must be used to supply air to system installed with a Series 746 or Series 746-LPA Dry Accelerator. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection, since air can be supplied continuously to the sprinkler system for an extended time period. Electrical Release Requirements Verify that an approved control panel is installed for proper system operation. 31.82 9999 Rev B Updated 02/2019 0 2019 Victaulic Company, All rights reserved. victaulic.com 10 \.J'(ctauIic victaulic.com 5.0 PERFORMANCE (Continued) Autoconvert Requirements System must be installed in conjunction with a Notifier RP-2001 family panel, System Sensor PDRP-2001, or a Potter 4410RC panel to be in compliance with FM Approvals. AutoConvert Trim: In the event of an AC power loss, the AutoConvert module latches from Closed to Open with a quick electrical pulse. To stay open, no further current draw is required as would be needed in a normally open solenoid. This opened pathway allows the included Series 776 Low Pressure Actuator to operate as a dry actuator, putting the preaction system into a Non-Interlocked condition, In this case, an electrical release from the FACP and an air loss in the system or the system air loss would allow the Series 769N valve to actuate, filling the pipe with water. Upon an AC power return, the Auto-Convert module senses the restoration and latches the path from the Series 776 Low Pressure Actuator closed, returning the preaction valve to its standard release method. 6.0 NOTIFICATIONS WARNING __1 i, ` , Read and understand all instructions before attempting to install any Victaulic I products. I Always verify that the piping system has been completely depressurized and I drained immediately prior to installation, removal, adjustment, or maintenance of I QO any Victaulic products. I • Wear safety glasses, hardhat, and foot protection. I I Failure to follow these instructions could result in death or serious personal injury I and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 1311, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 31.82 9999 Rev B updated 02/2019 C 2019 Victaulic Company. All rights reserved. victaulic.com 11 j(ctauiicr Scan for reference documents. victaulic.com 7.0 REFERENCE MATERIALS 30.22: FireLockiM 30.23: FireLock°M 30.32 FireLocknM 30.34: Automatic 30.33: Supplemental Compressor Packaue Fire-Pac Series 745 Water Motor Alarm Series Alarm Kit Series 758 Water Column Drain Kit Series 7C7 760 for FireLock NXTTM Valves Series 75D 30.35 FireLocklM Air Maintenance Trim Assembly Series 757 30.36: FireLockTM Air Maintenance Trim Assembly Series 757P 30.41: FireLocklM Manual Pull Station Series 755 30.61: FireLpcktM Double-Pneumatic Actuator Series 798 30.62: FireLocklM Low Pressure Actuator Series 767 30.63: FireLockTM Electric Solenoid Series 753E 30.64: pireLpcknM Dry Accelerator Series 746-LPA 30.65: FireLocklM Low Pressure Actuator Series 776 30.84 FireLock NXTTM AutoConvert Trim Assembly for Preaction Devices l-'°69N.Preaction l-'°69N.Preaction/DPA I-'69N.Preaction/EPA I-69N.Preaction/AC-Elec 1-769N.Preaction/AC-EP User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a Celerminatian as to the suitability of Victaulic products fur a particular end-use application, in accordance with industry standards and protect specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disc:aimer. intellectual property Rights No statement contained herein cor.cernisg a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or desgo in the infringement of any patent or other intellectual property right. The terms "Patented' or "Patent Posdirg" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. At products to be installed in accordance with current Victaulic inslui:ution/asoembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic insta/afion handbook or installation instructions of the product you are installing. Handbooks are included with each shiymert of Victaulic products, providing complete installation and assembly data, and are available in POE format snout websife at www.victaolic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for derails, Trademarks Victaulic and all other Vctaulic musks are toe trademarks or registered tradernarks of Vicioulic Company, and/or its affiliated entities, in the U.S. and/or other countries. I L82 9999 Rev.B Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 12 /ataubc High-performance firestop sealant that also helps minimize sound transfer Product Color: U Red Product Features Firestop tested up to 4 hours in accordance with ASTM E 814 (UL 1479) & CAN/ULC S1 15 Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079) Re-enterable / repairable Meets UL 1479 aging requirements Helps minimize sound transfer* Applied with conventional caulking equipment (excellent caulk rate) Extensive listed systems Sag-resistant Halogen-free Excellent adhesion Paintable Water clean up FIRE BARRIER SMOKE SEAL T041 FUN I PIrtnton SOUND BARRIER l54I QQ IIn sic ti-rated I wallassembly I )SSIP4 FILL, VOID OR CAVITY MATERIAl. FOR USE INTHROUGWPENETRA110N FIRESTOP SYSTEMS SEE UL RAE RESISTANCE DIRECTORY Rang 3M T"Fire Barrier Sealant CP 25WB+ Product Data Sheet 1. Product Description 3M"' Fire Barrier Sealant CP 25WB+ is a high-perfor- mance, ready-to-use, gun-grade, latex-based, intumescent sealant that dries to form a monolithic fire- slop seal that also acts as a barrier to airborne sound transmission. 3M" Fire Barrier Sealant C? 25WB+ helps control the spread of fire, smoke and noxious gasses before, during and after exposure to a fire when installed in accordance with a listed through penetration or fire-resistive joint assembly system. 3M" Fire Barrier Sealant C? 25WB+ firestops blank openings and penetrations passing through fire-rated floor, floor/ceiling or wall assemblies and other fire-rated interior building construction. The unique intumescent property of this material allows 3M"' Fire Barrier Sealant Cl' 25WB+ to expand and help maintain a firestop penetration seal for up to 4 hours as penetrants are exposed to fire. 3M" Fire Barrier Sealant Cl' 25WB+ exhibits excellent adhesion to a full range of construction substrates and penetrants. No mixing is required. USTED FILL, VOID OR CAVITY MATERIALS saGa Meets the intent ofLEED® VOC regulations—helps reduce the quantity of indoor air contaminants that may be odorous, irritating and harmful to the comfort and well-being of the installers and occupants. <250 g/L VOC contents (less H2O and exempt solvents). *Minimizes noise transfer—.STC-Rating of 54 when lester! in STC 54-rated wall assembly. 2. Applications High-performance 3M"' Fire Bather Sealant C? 25WB+ is ideal for sealing single or multiple through penetrations in fire-rated construction. 3M" Fire Barrier Sealant C? 25WB+ is typi- cally used in mechanical, electrical and plumbing applications to firestop openings created by the following penetrations in fire-rated floors, floor/ceilings or walls: metallic pipe, plastic pipe (excluding CPVC), conduit, power and communication cable, cable trays, busways, combos, insulated pipe and HVAC duct penetrations. 3M"' Fire Barrier Sealant Cl' 25WB+ is also used to firestop blank openings and static construction joints. <9> APPROVED SIJOJECTTO THE CONDmONSOFAPPROVAL AS A WALL & FLOOR PENETRATION FIRESTOP WHEN IRSTALLEDAS DESCRIBED IN THE CURRENT EDITION OF THE FMRC APPROVAl. GUIDE LISTED 00 LISTED c,1us 0 us Intertek Intertek FIRESTOP SYSTEMS FIRESTOP SYSTEMS SEE INTERTEK DIRECTDi SEE INTERTEI( DIRECTORY 3. Specifications 3M" Fire Bather Sealant Cl' 25WB+ Typically Specified Division shall be a one component, ready-to-use, gun-grade, latex-based, intumescent Division 7 firestop sealant capable of expanding a minimum of 3 times its dried volume Section 078400— Firestopping when exposed to temperatures above 1000°F (538°C), The material shall Related Sections Section 0784 16— Annular Space Protection be thixotropic and shall be applicable to overhead, vertical and horizontal Section 078443—Fire-Resistant Joint Sealants firestops. The sealant shall be listed by independent test agencies such as Section 07 86 00 — Smoke Seals Section 07 87 00 — Smoke Containment Barriers UL, Intertek or FM. 3M' Fire Barrier Sealant Cl' 25W0+ shall be tested Section 07 27 00 — Air Barriers to and pass the criteria of ASTM E 814 (UL 1479) Standard Test Method Section 2100 00 — Fire Suppression for Fire Tests of Penetration Firestop Systems, ASTM F 1966 (UL 2079) Section 22 00 00 — Plumbing Section 26 00 00 — Electrical Standard Test Method for Fire Resistive Joint Systems and CAN/ULC St 15 Standard Method of Fire Tests of Firestop Systems, 3M" Fire Bather Sealant Cl' 25WB+ meets the requirements of the IBC, IRC, .IFC, JPC, IMC, NFPA 5000. NEC (NFPA 70) and NFPA 101. For technieai support relating to 3M Are Protection Products and Systems, call' 1-800-328-1687 For more information on 3M Are ProtectIon Products, visit www3m.com/firestop 4. Physical Properties Color: Red Application Temperature Range: 400 to 122°F (4° to 50°C) (ASTM C 1299) Service Temperature Range: -200 to 180°F (-281 to 82°C) STC (ASTM E 90 and ASTM E 413): 54 when tested in STC 54-rated wall assembly Surface Burning (ASTM E 84): Flame Spread 0 Smoke Development 0 Hardness (ASTM D 2240 Shore A): 45 Tensile Strength: 85 psi (0.59 MPa) Volume Shrinkage (ASTMC 1241): 28% VOC Less H20 and Exempt Solvents: <1 gIL Dry: Under typical conditions of 75°F (23°C) and 50% RI-I,, sealant becomes tack-free in about ten minutes and dry-to-touch in 30 to 60 minutes. Full dry depends upon ambient conditions and volume of sealant. Typical dry rate is approximately 1/8 inch (3 mm) per day, Unit Volume: 10.1 Ill. oz tube (298.7 mL, 18.2 in?), 20 II, oz, sausage (591.5 mL, 36.1 in?), 27 Il, 02 tube (798.5 ml., 48.7 ia?). 2 gal. pail (7.57 L. 462 in?), 5 gal. pail (18,9 L, 1155 in?) Packaging, Storage, Shelf Life Packaging Product packaged in cartridge or pail is enclosed in HDPE plastic containers, sausage is packaged in aluminum foil wrap Storage 3M' Fire Barrier Sealant CP 25WB+ should be stored indoors in dry conditions between 40°F and 90°F (4°C and 32°C) in the original unopened package, Avoid repeated freeze / thaw exposures of the 3M" Fire Barrier Sealant CP 25WB+ prior to installation. Shelf Life 3M Fire Barrier Sealant CP 25WB+ shelf life is 12 months in original unopened containers from date of packaging when stored above 68°F (21C), Lot numbering (e.g. 8183AS): First digit = Last digit of year manufactured. Second to fourth digit = Julian Date, Letters = Random to distinguish between lot numbers Installation Techniques Consult a 3MAuthorized Fire Protection Products Distributor /Dealer or Soles Representative forApplicable UL, Intertek or other third-party drawings and system details. Preparatory Work The surface of the opening and any penetrating items should be cleaned to allow for the proper adhesion of the 3M" Fire Barrier Sealant CP 25WB+. Ensure that the surface of the substrates are not wet and are frost free. Sealant can be installed with a standard caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. Installation Details Install the applicable depth of backing material, if required, as detailed within the applicable UL, Intertek, FM or other third-party listed system. Cut the end of the 39" Fire Barrier Sealant CP 25WB+ tube spout to achieve the desired bead width when applying. Install the applicable depth of 3M' Fire Barrier Sealant CP 25WB+ into the opening flush with the surface of the substrate, or as detailed within the applicable listed system, at the depth for the assembly and rating that is required. Tool within 5 minutes. Clean all tools immediately after use with water. Limitations Do not apply 3M' Fire Barrier Sealant CP 25WB+ when surrounding temperature is less than 40°F (4°C) and in conditions where seals may be exposed to rain or water spray within 18 hours of application. Do not apply 3W Fire Barrier Sealant CP 25WB+ to building materials that bleed oil, plasticizers or solvent (e.g, impregnated wood, oil-based sealants, or green or partially vulcanized rubber). Do not apply 3M" Fire Barrier Sealant CP 25WB+ to wet or frost-coated surfaces or to areas that are continuously damp or immersed in water. NOTICE: This product is not acceptable for use with chlorinated polyvinyichioride (CPVC) pipes. Maintenance No maintenance should be required when installed in accordance with the applicable UL, Intertek, FM or other third- party listed system. Once installed, if any section of the 3M' Fire Barrier Sealant CP 25WB+ is damaged, the following procedure will apply: remove and reinstall the damaged section in accordance with the applicable listed system, with a minimum 1/2 in. (12.7 mm) overlap onto the adjacent material. Availability 3M Fire Barrier Sealant C? 25WB+ is available from 3M Authorized Fire Protection Products Distributors and Dealers. 3M" Fire Barrier Sealant C? 25WB+ is available in 10.1 ft, oz. cartridges (12/case), 20.0 ft. oz. sausages (10/case), 27.0 ft. oz. cartridg- es (6/case), 2 gallon pails (1/case) and 5 gallon pails (1/ease). For additional technical and purchasing information regarding this and other 3M Fire Protection Products, please call: 1-800-328-1687 or visit www.3m.com/firestop. Safe Handling Information Consult product's Material Softly Data Sheet MSDS) prior to handling and disposal. Important Notice to User Technical tntonnatla,u The technical information, recommendations and other statements contained in this document are based upon tests or experi- ence that 3M believes are reliable, but the accuracy or completeness of such information Is not guaranteed. Product Use: Many factors beyond 3M's control and uniquely within user's knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance 01 a 3M product, user is solely responsible for evaluating the 3M product and determining whether It Is fit for a particular purpose and suitable for user's method of application. Warranty and Limited Remedy: 3M warrants that each 3M Pro Protection Product will be free from defects in material and manufacture for 90 days Building and Commercial from the date of purchase from 3M's authorized distributor, 3M MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED SM WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If a 3M product does not conform to this warranty, the sole and ces Division exclusive remedy is, at 310's option, replacement of the 3M product or refund at the purchase price. 3M Center, Building 223-2h1-21 St Paul MN 55144-1000 USA Limitation of Lfabil1ty Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct 1:8_328_17 indirect, special, incidental or consequential, regardless at the legal theory asserted. www.3M.com/hrestop Please Recycle. Printed in USA il 3M 2010iJ1 Rights Reserved. 3M is a trademark of 3M Company. All other Literature Order Into: 98-0400-5012-6 trademarks are the property of their respective owners. lix I FIRE HARRIER SMOI(E S€ftl. 3M TM Fire Barrier Sealant IC 15WB+ Fj1' ii' Meets Optional I Product Data Sheet LJ Ltiequlrements I SOUND BARRIER 1. Product Description 3M" Fire Barrier Sealant IC 15WB+ is a cost-effective, one-part, I 541 I In I gun-grade, latex-based, intumescent firestop sealant that dries to form a monolithic firestop seal that also acts as a barrier to airborne sound transmission, 3M" Fire Barrier Sealant IC 15WB+ firestops through penetrations ,clssIp passing through fire-rated floor, floor/ceiling or wall assemblies, as well as other fire-rated interior building 14 partitions and assemblies (e.g, static construction joints or blank openings). In addition, the unique intumescent property of this material allows 3M" Fire Bather Sealant IC 15WB+ to expand and help maintain a firestop penetration seal for up to 3 hours as penetrants are exposed to fire. 3M' Fire Bather Sealant IC 15WB+ FILL VOID, OR CAVITY bonds to most construction substrates, including: gypsum wallboard, concrete, metals, wood, plastic (including FOR LIRE IN JOINT SYSTEMS, THROUGH-PENETRATION RRESTOP SYSTEMS CPVC) and cable jacketing. No mixing is required. AND PERIMETER CONTAINMENT SYSTEMS SEE Ii FIRE RESISTANCE DIRECTORY or FBC Product Features • Firestop tested up to 3 hours in • Sag-resistant accordance with ASTM E 814 • Halogen-free C\/US (UL 1479), ASTM E 1966 (UL 2079) & CAN/ULC-SI 15 • Excellent adhesion USTED Intertek Re-enterable/repairable FILL VOID OR CAVITY FIRESTOf' SYSTEMS P2"] • CPVC compatible • >. Excellent caulk rate MATERIALS SEE INTERTEK DIRECTORY -' • Expanded fire protection systems 90G0 Helps minimze sound nsfe • Palatable — • Water clean up Cost-effective firestop sealant Complies with the intent of LEEE*i NC-EQ Credit 4.116r Low-Emitting Materials: Adhesives and Sealants, available In tube, pall or sausage. contains <250 gIL VOC contents (less 11,0 and exempt solvents per 5CR QMD Ride 1168). Product Color: fl Yellow. *Minimizes noise trwofrr—STC-Raring of 54 when tested in STC 54-rated wall assembly. 2. Applications 3M" Fire Barrier Sealant IC 15WB+ is a general-purpose intumescent firestop ideal for sealing single or multiple through penetrations in fire-rated construction. 3M" Fire Barrier Sealant IC 15W8+ is typically used in mechanical, electrical and plumbing applications to firestop openings created by the following penetrations in fire-rated floors, floor/ceilings or walls: metallic pipe, plastic pipe, conduit, power and communication cable, cable trays, busways, combos, insulated pipe and HVAC duct penetrations. 3M' Fire Barrier Sealant IC 15W8+ is also used to firestop blank openings and static construction joints. Specifications 3M" Fire Barrier Sealant IC 15WB+ shall be a one component, ready-to-use, gun-grade, latex-based, intumescent firestop sealant capable of expanding a minimum of 3 times at 1000°E The material shall be thixotropic and be applicable to overhead, vertical and horizontal firestops. The sealant shall be listed by independent test agencies such as UL, ULC, lntertek or FM, 3M" Fire Barrier Sealant IC 15WB+ shall be tested to and pass the criteria of ASTM E 814 (UL 1479) Standard Test Method for Fire Tests of Penetration Firestop Systems, ASTM E 1966 (UL 2079) Standard Test Method for Fire Resistive Joint Systems and CAN/ ULC-S 115 Standard Method of Fire Tests of Firestop Systems. 3M" Fire Barrier Sealant IC 15WB+ meets the requirements of the IBC, IRC, NBCC, IFC, IPC, IMC, NFPA 5000, NEC (NFPA 70) and NFPA 101, Typically Specified NiasterFormat (2004) Section 07 8400- Firestopping Related Sections Section 07 2700-Air Barriers Section 0784 16- Annular Space Protection Section 078443-Fire-Resistant Joint Sealants Section 078600-Smoke Seals Section 07 87 00- Smoke Containment Barriers Section 0792 13- Elastotneric Joint Sealants Section 0792 19- Acoustical Joint Sealants Section 2100 W - Fire Suppression Section 220000-Plumbing Section 230000-Heating. Ventilating, and Air Conditioning (HVAC) Section 260000- Electrical For technical support relating to 3M Are Protection Products and Systems, catl: 18OO-328-1687 For more information on 3M Fire Protection Products visit www.3m.com/flregtop ~Ewu 4, Performance & Typical Physical Properties Color: Yellow Application Temperature Range: 40° to 122°F (4° to 50°C) (ASTM C 1299) Service Temperature Range: -20° to 180°F (-28° to 82°C) STC Acoustic Barrier: 54 when tested in STC 54 rated (ASTM E 90 and ASTM E 413) wall assembly Surface Burning (ASTM E 84): Flame Spread 5, Smoke Development 50 Hardness (ASTM D 2240 Shore A): 70 Tensile Strength: 85 psi (0,59 MPa) Volume Shrinkage (ASTM C 1241): 28% VOC Less H20 and Exempt Solvents: <2 g/L Dry; Under typical conditions of 75°F (23°C) and 50% RH., sealant becomes tack-tree in about ten minutes and dry-to-touch in 30 to 60 minutes. Full dry depends upon ambient conditions and volume of sealant. Typical dry rate is approximately I/S inch (3 mm) per day, Unit Volume: 10,1 11. oz tube (298.7 nil, 18,2 in?). 20 II, oz, sausage (591,5 ml, 36,1 in?), 27 IL oz tube (798,5 not, 48,7 in?), 45 gal. pail (17.03 L. 10395 in?) Packaging, Storage, Shelf Life Packaging Product packaged in cartridge or pail is enclosed in I-lOPE plastic containers, sausage is packaged in aluminum foil wrap. Storage 3M°' Fire Barrier Sealant IC ISWB+ should be stored indoors in dry conditions between 40°F and 90°F (4°C and 32°C) in the original unopened package. Avoid repeated freeze / thaw exposures of the 3M"' Fire Barrier Sealant IC 15WB+ prior to installation, Shelf Life 3M" Fire Barrier Sealant IC I SWB+ shelf life is 12 months in original unopened containers from date of packaging when stored above 68°F (2°C), Lot numbering (e.g. 8183AS): First digit = Last digit of year manufactured, Second to fourth digit Julian Date, Letters Random to distinguish between lot numbers Installation Techniques Consult a 3M Authorized Fire Protection Products Distributor IDea/er or Sales Representative for applicable UL, cUL, ULC, Intertek, FM or other third-party drawings and system details, Preparatory Work The surface of the opening and any penetrating items should be cleaned to allow for the proper adhesion of the 3M" Fire Barrier Sealant IC ISWB+, Ensure that the surface of the substrates are not wet and are frost free. Sealant can be installed with a standard caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. Installation Details Install the applicable depth of backing material, if required, as detailed within the applicable UL, cUL, ULC, Intertek, FM or other third-party listed system. Cut the end of the 3M" Fire Bather Sealant IC 15WB+ tube spout to achieve the desired bead width when applying. Install the applicable depth of 3M' Fire Barrier Sealant IC I SWB+ into the opening Rush with the surface of the substrate, or as detailed within the applicable listed system, at the depth for the assembly and rating that is required. Tool within 5 minutes. Clean all tools immediately after use with water, Limitations Do not apply 3M" Fire Barrier Sealant IC I SWB+ when surrounding temperature is than less 40°F (4°C) and in conditions where seals maybe exposed to rain or water spray within 18 hours of application. Do not apply 3M"' Fire Barrier Sealant IC I5WB+ to building materials that bleed oil, plasticizers or solvent (e.g. impregnated wood, oil-based sealants, or green or partially vulcanized rubber). Do not apply 3M" Fire Barrier Sealant IC ISWB+ to wet or frost-coated surfaces or to areas that are continuously damp or immersed in water. Maintenance No maintenance is expected to be required when installed in accordance with the applicable UL, cUL, ULC, Intertek, FM or other third-party listed system. Once installed, if any section of the 3M7' Fire Barrier Sealant IC I5WB+ is damaged, the following procedure will apply: remove and reinstall the damaged section in accordance with the applicable listed system, with a minimum 1/2 in. (12.7 mm) overlap onto the adjacent material. Availability 3M"' Fire Barrier Sealant IC 15WB+ is available from 3M Authorized Fire Protection Products Distributors and Dealers. 3M"' Fire Bather Sealant IC ISWB+ is available in 10,1 fi, oz, cartridges (3M ID 98-0400-5509-1, 12/case), 20,0 11. oz. sausages (3M ID 98-0400-5512-5, 10/case), and 4.5 gallon pails (3M ID 98-0400.5510-9, 1/case). For additional technical and purchasing information regarding this and other 3M Fire Protection Products, please call: 1-800-328-1687 or visit www.3m.com/firestop. Safe Handling Information Consult country-of-use Material Safety Data Sheet (MSDS) prior to handling and disposal. Important Notice to User; Technical Information; The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed. Product Use: Many factors beyond 3M's control and uniquely within users knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for users method of application Warranty and Limited Remedy' 3M warrants that each 3M Fire Protection Product will he free from defects in material and manufacture for UN 90 days from the date of purchase from 3M a authorized distributor. 3M MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE. If a 3M product does not conform to this ;warranty, Building and Conummial LimItation the sole and exclusive remedy is, at 3M's option, replacement of the 3M product or refund of the purchase price. of uabfllty, Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether Services Division direst, indirect, special, incidental or consequential, regardless of the legal theory asserted. 3M Center, Building 223-2N-21 St. Paul, MN 55144-1000 USA Please Recycle. PrftTt5U In USA. 1-800-328-1687 0 3M 2012. All rights reserved. 3M is a trademark of 3M. Used under license In Canada. All www.3M.com/ftrestop 98-0400-5077-9 REV R other trademarks are the property of their respective owners. -- ----- Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipef it is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 IJONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com -u © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc.bA FBC, BlazeMaster®, FlowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. DIEGO SEAL, 7635 RONSON ROAD • SAN DIEGO, CA 92111 • TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: salessandiegoseaLcom • VISIT US AT: wwwsandiegoseaLcom PTFE Thread Sealant Tapes Made In the USA )ur thread sealant tape breaks clean without shredding )r warping, identifying it as a product that can be trusted ., o perform reliably when the job is completed and the ressure is on. Standard Grade Our standard grade PTFE Thread Sealant Tape is for those applications that do not require the sealing properties of a , f 4 \ 7 premium grade thread sealant. This is intended to be used for general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, clean, -- 7 economical sealing of male pipe threads of all sizes and the liquid reduces risk of system contamination common with and paste sealants. lih-Density Thread Sealant Tape t is effective and efficient so you can use less tape. Tears cleanly.. .seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will Withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. ull Density Yellow Gas Une PTFE Thread Sealant Tapes isk of system contamination common with liquid and paste sealants. Our full density premium and gas line tapes meet All Spec A-A 58092 for liquid & gaseous oxygen applications. The self-lubricating quality of this unsintered tape nakes joints easy to assemble and disassemble. Totally maintenance free, full density PTFE thread sealant tape is 'Irtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (- 40°C) to +500°F (+260°C), and pressures from a hard vacuum to 10,000 PSI. yplcal properties of PTFE thread sealant tape are as follows: _Properties tGrade r Standard Grade Premium Grade Premiuni Grade emtum Grade - Yellow tandard Density ugh Density :ull Density 1u0 Density 4axi .mum sealing omplies with certain Description he economical choice lore sealing power ower. So efficient ' Iding codes requiring ellow, thicker, more ou can useless lense tape for gas ape. ervice lines Color While or colors White or colors JVhite or colors fYeilow Density tandard 0.5 to 0.7 tandard 1.0 to 1.2 tandard 1.5 standard 1.6 Thickness .003° to 0.0035" .003" to 0.0035° .003" to 0.0035" I itandard widths & " x 260" " x 520° " x 1296° " x 260" " x 520" 6" x 1296" enetlis A" x 260" " x 520" 4" x 1296" "x260" "x520" 1"x1296" Quantity 44 rolls per box 44 rolls per 44 rolls per box ox _010F Typical Use Vhite All industrial applications. Made from virgin PTFE ink For use in plumbing and pipe fittings (water and steam lines) I For stainless steel pipe/fittings teen For oxygen applications (ellow For gas line use VIA' SRN DIEGO SEAL, INC 7635 RONSON ROAD • SAN DIEGO, CALIFORNIA 92111 TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: sales@sandiegoseal.com • VISIT US AT: www.sandiegoseal.com