HomeMy WebLinkAbout2548 CAMPBELL PL; ; FPC2020-0062; PermitIF1 1 riiii F1 El t~('City of Carlsbad Fie1Rnn7iit Print Date: 10/06/2020 Permit No: FPC2020-0062 Job Address: 2548 CAMPBELL P1, CARLSBAD, CA 92009-1700 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132611700 Track #: Applied: 04/06/2020 Valuation: $1,813,890.00 Lot #: Issued: 04/27/2020 Occupancy Group: Project #: Finaled Close Out: 10/06/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASAT BLDG N4 -REVISED PLANS FOR NEW ALARM SYSTEM (ADDRESSABLE, 122 DEVICES) FPContractor: iii ENTERPRISES 533 5 VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE New Alarm System $1,265.00 FIRE Plan Review Per Hour - Office Hours $204.00 Total Fees: $1,469.00 Total Payments To Date: $1,469.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 1222 NTEIPISES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS VIASAT BUILDING N4 T.I. 2548 CAMPBELL PLACE CARLSBAD, CA 92009 FIRE ALARM SYSTEM cMATERIAL DATA SHEETS - BILL OF MATERIALS NOTIFIER NFS-320 FIRE ALARM CONTROL PANEL W/NOTIFIER UDACT-2 TRANSMITTER CSFM# 7165-0028:0243 TELGUARD TG-7FS CELLULAR FIRE ALARM COMMUNICATOR CSFM# 7300-1402:0109 SPACE AGE ELECTRONICS INC. FAD SSU00685 FIRE ALARM DOCUMENTS RED CSFM# 7300-0553:0110 NOTIFIER FCPS-24S6 REMOTE POWER SUPPLY CSFM# 7315-0028:0225 NOTIFIER FDU-80 80 CHARACTER LCD SERIAL REMOTE ANNUNCIATOR CSFM# 7120-0028:0209 NOTIFIER NBG-12LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:0199 NOTIFIER FSP-951 ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0028:0503 NOTIFIER FSt-951 ADDRESSABLE HEAT DETECTOR CSFM# 7270-0028:0502 NOTIFIER FMb'l—lO]. ADDRESSABLE MONITOR MODULE CSFM# 7300-0028:0219 NOTIFIER FRM-1 ADDRESSABLE RELAY MODULE CSFM# 7300-0028:0219 SYSTEM SENSOR INNOVAIRFLEX DNR DUCT DETECTOR HOUSING WI FSP-951R HEAD CSFM# 3242-1653:0209 CSFM# 7272-0028:0503 SYSTEM SENSOR P2WL HORN/STROBE, SELECTABLE CANDELA - WALL MOUNT CSFM# 7135-1653:0503 SYSTEM SENSOR PC2WL HORN/STROBE, SELECTABLE CANDELA - CEILING MOUNT CSFM# 7135-1653:0503 SYSTEM SENSOR SCWL STROBE ONLY CEILING MOUNT, MULTI—CANDELA CSFM# 7135-1653:0504 DN-71 12:N • A-14 NFS-320 LF Intelligent Addressable 0 Fire Alarm System by Honeywell General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. The panel can be configured with just a few devices for small build- ing applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional periph- eral equipment to suit the application. Wireless fire protection can be added with the SWIFT wireless gateway and devices. For installations using NFS-320C, an optional ACM Series annun- ciator can be mounted in the same cabinet (up to 48 zones/points, order separately; see DN-60085). NOTE: Unless called out with a version-specific "R", "C" or "E" at the end of the part number, "NFS-320" refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E. Features Certified for seismic applications when used with the appropri- ate seismic mounting kit. Approved for Marine applications when used with listed com- patible equipment. See DN-60688. One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. Up to 159 detectors and 159 modules per SLC; 318 devices maximum. - Detectors can be any mix of ion, photo, thermal, or multi-sen- sor; wireless detectors are available for use with the FWSG. - Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. Optional FWSG Wireless SWIFT Gateway supports wireless SLC devices. Standard 80-character display. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX- Works, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX- Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020). Up to 54 nodes when DVC- EM is used in network paging. 6.0 A power supply with four Class NB built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online or offhine programming utility. Upload! Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. NFS-320 Alarm Verification selection per point, with automatic counter. Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. NAC coding functions: - March time. - Temporal. - California two-stage coding. - Canadian two-stage. - Strobe synchronization. Field-programmable on panel or on PC with VeriFire® Tools program check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 - 200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Extensive, built-in transient protection. Powerful Boolean logic equations. FLASHSCAt%P INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion - 0.5 to 2.5%/foot obscuration. - Photo —0.5 to 2.35%/foot obscuration. - Laser (VIEW®) —0.02 to 2.0%/foot obscuration. - Acclimate® PlusTM —0.5 to 4.0%/foot obscuration. - IntelliQuad - 1.0 to 4.0%/foot obscuration. - lntelliQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Degraded mode - in the unlikely event that the NFS-320's pri- mary microprocessor fails, FlashScan detectors revert to degraded operation and can activate the control panel's NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. iDN-7112:N • 3/24/17 - Page 1 of 6 TI T[j i LJJ [_____________ FDU 80 LCD2-80 EIA-485 FSC-851 IntelliQuad FAPT-851 Acclimate PLUS FSL-751 FlashScan VIEW FSP-851 Photo FSl-851 Ion FST-851 Thermal FSA-8000 etc. EIA-485 Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. FSL-751 VIEW (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the tire location. Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATd PLUS- LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without opera- tor intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and ther- mal technology. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. INTELLIGENT FAAS10 DETECTORS FSA-5000, FSA -8000, FSA- 20000 AND FSA-20000P Connects directly to the SLC loop of compatible ONYX series panels. Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event program- ming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. Advanced algorithms reject common nuisance conditions FSA-5000 covers 5,000 square feet through one pipe. FSA-8000 covers 8,000 square feet through one pipe. FSA-20000 covers 28,800 square feet through one to four pipes. FSA-20000P covers 28,800 square feet through one to four pipes. Supports addressable pipes to pinpoint location of alarm events. FCO-851 INTELL,QUADTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp- 4(00) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. VOICE FEA TURES Integrates with FirstCommand Series. See DN-60772. Telephone applications require NFC-FFT. Up to 32 remote displays SLC Intelligent Loop - - 5E7v1&S 1.4 if th I 0 JEM ACM-8R Relay Control - lI € y y . FWSG NBG-12LX I 4r XP6110 I/O Modules FMM-1 I FCM-1 IDC NAC RM-1 Relay Contact 2048 annunciator/control points ACM/AEM-24AT LED Annunciator L°1 i° LDM-32 Custom Graphics Sample System Options EIA-232 Optional 318-point UDACT Dual phone lines to Central Station PRN Series Printer 7112blok-2014.wmf Page 2 of 6— 0N-7112:N • 3/24/17 HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM) 120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E). Displays battery current/voltage on panel (with display). FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS-320 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashScan is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS-320 to have the largest device per loop capacity in the industry —318 points - yet every input and output device is sampled in less than two seconds. The microprocessor- based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed micro- computer used by the NFS-320. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces mainte- nance requirements by allowing the system to automatically per- form the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove tran- sient noise signals, such as those caused by electrical interfer- ence. Maintenance Warnings: When the drift compensation performed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Main- tenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change auto- matically between day and night. Nine levels of pre-alarm sensitiv- ity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self- Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a por- tion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320, like all NOTIFIER intelligent panels, has the exclusive feature of program creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS- 320 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the pro- gram to be entered with independent per-point segments, while the NFS-320 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confi- dence in the site-specific software. It is Windows®based and pro- vides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-320 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320's flexible system design. Wiring: When designing the cabinet layout, consider separation of power-limited and non-power-limited wiring as discussed in the NFS -320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a Network Communication Module or High-Speed Net- work Communication Module (HS-NCM can support two nodes; see "Networking Options" on page 4). These modules can be installed in any option board position (see manual), and additional option boards can be mounted in front of them. KDM.R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout). 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Disabled; Control Active; Abort; Pre-Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. Product Line Information 'Configuration Guidelines" on page 3 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 4 "Compatible Devices, EIA-232 Ports" on page 4 "Compatible Devices, EIA-485 Ports" on page 4 "Compatible Intelligent Devices" on page 4 "Enclosures, Chassis, and Dress Plates" on page 5 "Other Options" on page 5 CONFIGURATION GUIDELINES The NFS-320 system ships assembled: description and some options follow. See "Enclosures, Chassis, and Dress Plates" on page 5 for information about mounting peripherals. NOTE: Stand-alone and network systems require a main display. On stand-alone systems, the panel's keypad provides the required display. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYX Works annunciation device is required. (For NCA-2, see DN-7047.) r"NFS-320: The standard, factory-assembled NFS-320 system "includes the following components: one control panel mounted on chassis (120 V operation - ships with grounding cable, battery interconnect cables, and document kit); includes integral power supply mounted to the main circuit board; one primary display KDM-R2 keypad/display; and one cabinet for surface or semi-flush mounting. Purchase batteries separately. One or two option boards may be mounted inside the NFS-320 cabinet; additional option boards can be used in remote cabinets. (Non-English ver- sions also available. NFS-320-S NFS-320-PO.) NFS-320R: Same as NFS-320, but in red enclosure. DN-71 12:N • 3/24/17 - Page 3 of 6 NFS-320C: Based on NFS-320 above. NFS-320C supports instal- lation of an optional ACM-series annunciator in the same cabinet. UL- and ULC-listed. (Non-English version also available: NFS- 320C-FR.) For NFS-320C, see DN-60085. NFS-320CR: Same as NFS-320C but in a red enclosure. For NFS- 320C, see DN-60085. NFS-320E: Same as NFS-320, but with 240 V operation. (Non- English versions also available. NFS-320E-SF NFS-320E-PO.) TR-320: Trim ring for the NFS-320 cabinet. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available. See DN-6861. HS-NCM-W/MF/SF/WMFIWSF/MFSF: High-speed Network Com- munications Modules. Wire, single-mode fiber, multi-mode fiber, and media conversion models are available. See DN-60454. RPT-W, APT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. See DN-60499. NWS-3: NOTI.FIRE.NETTM Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN-60756. VESDA-HLI-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOT[-FIRE-NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10.0 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S61S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NFC-50/100: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, digital message generator, and Class A or Class B speaker circuits. See DN-60772. COMPATIBLE DEVICES, EIA -232 PORTS PRN-7: 80-column printer. See DN-60897. VS4095/5: Printer, 40-column, 24 V. Mounted in external backbox. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals; mount on NFS-320 chassis. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered- up switch selection) by point to be red, green, or yellow; the Trou- ble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-6820. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD dis- play. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits (HVAC only). See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity circuits and one municipal box circuit; mount on NFS-320 chassis or remotely. See DN-6860. IJDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. tJZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microprocessor-con- trolled, field-programmable from lBM®compatible PCs (requires optional programming kit). Mounts in BB-UZC. See DN-3404. COMPATIBLE INTELLIGENT DEVICES NOTE: "A" suffix indicates ULC-Listed model: FWSG Wireless SWIFT Gateway: Addressable gateway supports wireless SLC devices. Not appropriate for ULC applications. See DN-60820. FSA-5000: Intelligent FAAST® XS Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 5,000 sq.ft. For Canadian applications, order FSA-5000A. FSA-8000: Intelligent FAAST® XM Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 8,000 sq.ft. For Canadian applications, order FSA-8000A. See DN-60792 FSA-20000: Intelligent FAAST® XI Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 28,800 sq.ft. For Canadian applications, order FSA-20000A. See DN-60849. FSA-20000P FAAST® XT PRO Intelligent Aspiration Detector For applications up to 28,800 sq. ft. (2601 sq. m.) through one to four addressable pipes. See DN-60792 FSB-200(A): Intelligent beam smoke detector. See DN-6985. FSB-200S(A): Intelligent beam smoke detector with integral sensi- tivity test. See DN-6985 FSC-851(A): FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-604 12. FCO-851(A): FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSI-851(A): Low-profile FlashScan ionization detector. See DN- 6934. FSP-851(A): Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851T(A): Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FSP-851 R(A): Remote-test capable photoelectric detector for use with DNR(W) duct detector housings. See DN-6935. FST-851(A): FlashScan thermal detector 135°F (57°C). See DN-6936. Page 4 of 6- DN-71 12:N • 3/24/17 FST-851R(A): FlashScan thermal detector 135°F (57°C) with rate- SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery of-rise. See DN-6936. bracket for two 55 AH batteries. FST-851H(A): FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851(A): FlashScan Acclimate Plus low-profile multi-sensor detector. See DN-6937. FSL-751(A): FlashScan VIEW laser photo detector. See DN-6886. DNR(A): InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 R separately). Replaces FSD-751 PL/FSD- 751 RPL. See DN-60429. DNRW(A): Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. 1322481: Isolator base for low-profile detectors. See DN-60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501 (A): European-style, 4' (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of pro- ducing a variety of tone patterns including ANSI Temporal 3. Com- patible with sychronization protocol. See DN-60054. B200S-LF: Low-frequency version of B200S. See DN-60054. B200SR: Sounder base, Temporal 3 or Continuous tone. See ON- 60054. B200SR-LF: Low-frequency version of B200SR. See DN-60054. FMM-1: FlashScan monitor module. See DN-6 720. FDM-1(A): FlashScan dual monitor module. See DN-6 720. FZM-1(A): FlashScan two-wire detector monitor module. See ON- 6720. FCM-i(A): FlashScan control module. See DN-6 724. FCM-i-REL(A): FlashScan releasing control module. See ON- 60390. FRM-11(A): FlashScan relay module. See DN-6724. FDRM-1(A): FlashScan dual monitor/dual relay module. See ON- 60709. NBG-12LX: Manual pull station, addressable. See DN-6 726. ISO-X: Isolator module. See DN-2243. ISO-6: Six Fault isolator module. For Canadian applications order ISO-6A. See DN-60844. XP6-C(A): FlashScan six-circuit supervised control module. See DN-6924. XP6-MA(A): FlashScan six-zone interface module; connects intel- ligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R(A): FlashScan six-relay (Form-C) control module. See ON- 6926. XP10-M(A): FlashScan ten-input monitor module. See ON-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. BB-UZC: Backbox for housing the UZC-256. Required for NFS- 320 applications. Black. For red, order BB-UZC-R. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above, but red. SEISKIT-320/B26: Seismic mounting kit. Required for seismic-cer- tified applications with NFS-320 and BB-26. Includes battery bracket for two 26 AH batteries. OTHER OPTIONS 411: Slave Digital Alarm Communicator. See DN-6619. 411UDAC: Digital Alarm Communicator. See DN-6 746. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for inter- net communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IR See DN-60408. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mount- ing bracket; Red. For Black order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and sec- ondary ports of a DACT. See DH-60769. BACKBOXES NOTE: "C" suffix indicates ULC-Listed model: ABF-1B Annunciator Flush Box. ABF-i DB(C) Annunciator Flush Box with Door. ABF-213 Annunciator Flush Box ABF-2DB(C) Annunciator Flush Box with Door ABF-413 Annunciator Flush Box ABS-1TB(C) Annunciator Surface Box ABS-1 B(C) Annunciator Surface Box ox ABS-41D(C) Annunciator Surface Box NFS-320-RB: Replacement board with central processing unit (CPU). NOTE: Keypad must be removed before shipping old unit out for repair. NFS-320-RBE: Replacement CPU, Export. NFS-320-RB-PO: Replacement CPU, Portuguese. NFS-320-RB-POE: Replacement CPU, Export, Portuguese. NFS-320-RBC-FR: Replacement CPU, Canadian French. NFS-320-RB-SP: Replacement CPU, Spanish. NFS-320-RB-SPE: Replacement CPU, Export, Spanish. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. FMM-101(A): FlashScan miniature monitor module. See DN- ABS-213 Annunciator Surface Box 6720. ABQ-2D/rl Annunciator SEISKIT-BB25: Seismic mounting kit for the BB-25. Includes bat- tery bracket for two 26 AH batteries. DN-71 12:N • 3/24/17 - Page 5 of 6 System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits . 1 Intelligent detectors .............................................................159 Addressable monitor/control modules..................................159 Programmable internal hardware and output circuits ..............4 Programmable software zones...............................................99 Special programming zones...................................................14 LCD annunciators per NFS-320/-320E ................................32 ACS annunciators per NFS-320/-320E ...........................32 addresses x 64 points SPECIFICATIONS Primary input power - NFS-320: 120 VAC, 50/60 Hz, 5.0 A. - NFS-320E: 220/240 VAC, 50/60 Hz, 2.5 A. Current draw (standby/alarm): - NFS-320(E) board: 0.250 A. Add 0.035 A for each NAC in use. - KDM-R2 (Backlight on): 0.100 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet. Standard notification circuits (4): 1.5 A each. Resetlable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: -1.25 A. - 0.50 A. Non-resettable 5V power: 0.15 A. Battery charger range: 18 AH -200 AH. Use separate cabinet for batteries over 26 AH. Float rate: 27.6 V. CABINET SPECIFICATIONS NFS-320 cabinet dimensions: Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) height; 5.81 in. (14.76 cm) depth. Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) height; 0.75 in. (1.905 cm) depth. Trim ring: Molding width is 0.905 in. (2.299 cm). Shipping weight (without batteries): 36.15 lb. (16.4 kg). -.-CSFM: 7165-0028:0243. 128-07-E.-- Fire Dept. of New York: COA# 6212. City of Chicago. ULC Listed: S527-11 NOTE: For additional information on UL- and ULC-listed model NFS-320C, see DN-60085. For information on NFS-320SYS, see DN-60637. Marine Applications: Marine approved systems must be config- ured using components itemized in this document. (See Main Sys- tem Components, in "Product Line Information.) Specific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the following agencies: US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 CFR and 161 .002). Lloyds Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS-320 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). (NFS-320 version 20 or higher). ULC-5527-11 Standard for the Installation of Fire Alarm Sys- tems. LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM- 4). REMOTE STATION (Automatic, Manual, Waterflow and Sprin- kler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). Not applicable for FM. CENTRAL STATION (Automatic, Manual, Waterflow and Sprin- kler Supervisory) (requires DACT). EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). CBC 2007 (Seismic). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/ 32- 120°F and at a relative humidity 93% ± 2% RH (noncondens- ing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F. AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS-320 con- InteIIiQuad°M, NOTI.FIRE.NETT', ONYXWorks°", and SWIFTTM are trol panel. In some cases, certain modules may not be listed by trademarks; and Acclimate® PIuSTM, FirstCommand®, FlashScan®, certain approval agencies, or listing may be in process. Consult Intelligent FAAST®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are factory for latest listing status. registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a ULJULC Listed: S635. registered trademark of IBM Corporation. FM Approved. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I- This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. UI_ We cannot cover all specific applications or anticipate all requirements. __ _ BCI INC M1111111FACTENS All specifications are subject to change without notice. QUALITY SYSTEMS Country ot Origin: USA For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6- DN-7112:N • 3/24/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0243 Page 1 of 4 CATEGORY: 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models NFS2-640, NFS-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System * Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-61 0, AMPS-24; Addressable power supply/charger ADP-413, -A4, -1, -2, DP-D15P2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP4, BP24; Battery Dress Plates CAB-3/4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A4/1/2, DP-DISP2; Dress Panel DPI-232; Panel Interface DR-A4, DR-A48, DR-A413R, DR-A4R; Door Assembly DR-AA4, DR-M413, DR-M4BR, DR-M4R; Door Assembly DR-133F; Door Assembly DR-134, DR-13413, DR-B4BR, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 2 of 4 EQ Series; Cabinets EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-24S6, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 Multiple Module with two Relay Outputs FDU-801-80G; Remote Annunciator FlRSTVlSION-LCD/ENC; Interactive Firefighters display/enclosure FRM-1; Relay Module FTM-1; Control Module FZM-1 FMM-1 FMM-1 01; Monitor Modules HS-NCM-W/-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-12LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/50ZS/ZST; Voice Evacuation Control Panels NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/N F/-HNW/-H NMF/-HNSF/-TS/-EW-TS/-N F-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTI.FIRE.NET, Wire/Fiber! with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 3 of 4 SCE-8; Smoke Control Expander SCS-81-; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C41-D3N/-D4; Trim Ring UDACTUDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-213; Dress Panel XP5-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4RI-C4/-C4R/-D41-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-1; Audio Voice Link BDA-25V1-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMlC-1, CMlC-RP; Microphone Assembly DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-50255F; Digital Audio Amplifiers DAA-5070F/DAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-75255F; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1SA; Remote Microphone *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60686:A1 @ NOTOFUER 0 Communicator Transmitter by Honeywell General UDACT.2 Universal Digital Alarm The Universal Digital Alarm Communicator Transmitter (UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTl.FIRE.NETTM. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Oft-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Maximum of 14 point trouble messages transmitted per hour. Dual phone lines with line voltage detect. Compact in size: 6.75" x 4.25' (17.145 x 10.795 cm). USB port for upload/download programming. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1B/R). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. UDACT-2 Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. Real-time clock. Extensive transient protection. EIA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. DN-60686:A1 .412/12—Page 1 of 2 Communication Formats Ademco Contact ID 4+2 Standard SIA NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format - only Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterflow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications Standby current: 40 mA. Current while communicating: 75 mA. Maximum current while communicating and with open collector output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULIULC Listed: S635 FM Approved CSFf7T65-0028:0243(NFS2-640/320), 7165-0028:0224 (NFS2-3030) FDNY: COA#6085, COA#6098 Ordering Information tTACT-271Jniversal Digital Alarm Communicator Transmitter. includes operating and programming instructions, and mounting hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94' H x 4.63" W x 2.50" D (cm: 25.248 H x 11.760 W x 6.350 D). UBS-1 B: Metal enclosure with solid door, Black. UBS-1BR: Metal enclosure with solid door, Red. R-10E: SPDT Form-C relay. Contacts rated for 10 A © 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A © 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. UL Listed Receivers The chart below shows UL listed receivers compatible with the UDACT-2. A check in the protocol column indicates the receiver supports that protocol. Receiver 4+2 Standard 1800/2300 Ademco Contact ID SIA Ademco 685(1) V V Ademco MX8000 (2) V V Silent Knight 9500 (3) V V V Silent Knight 9800 (4) V V V FBI CP220FB (5) V V V Osborne Hoffman 2000E (6) V V Radionics 6600 (7) V V SurGard MLR2 (8) SurGard System III (9) v V SurGard MLR-2000 (10) V With 685-8 Line Card with Rev 4.4d software With 124060V206B and 124063 Line Card Rev B With version V2.4 Receiver & 126047 Line Card Rev G With 124077V2.00 Receiver &126047 Line Card Rev M With software V3.9 With V.7301 Receiver S/W With 01.01.03 Receiver SIW & Line Card 01.01.03 With software V1.86 With sotware V1.72 With DSP4016 and V1.6 Line Card NOTI.FIRE.NETTM is a trademark and Notifier® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGIMBNS III MMIFACTMNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60686:A1 • 4/2/12 tdJI Utd1l llSJe r&an-ce:dIp'?lil5 li o ®1Dth liii IMh o TG=7FS LTE-A t/NT7LAFO1 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD COMMERCIAL FIRE PRODUCT FEATURES . Certified for use on the AT&T LTE network for long, sunset- free installation. I Meets UL 864 requirements for sole, primary or backup path communications. I Minimizes false alarms by providing dual paths for self-tests. I Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. [St—andThIt Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies ULC Listings S545 • Canadian household fire warning systems S304 Canadian commercial burglary alarm systems C0123 Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telguard.com. TG=7FS LIE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD ransmit dWër Power Gonsumption 60 A(a 0 A a s iio ransformer: •21VkC 8Gi5'A se u. [i1jr_a gscei Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. lIDMe Mir Telguard, a Division of Telular Corporation 3225 Cumberland Blvd SE • Suite 300 • Atlanta GA 30339 USA 800-229-2326, Option 5 www.Telguard.com Copyright ©2017 Telular Corporation All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. - cJ300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7LA001 *TG7LM01 TG7LA002, *TG7lJF01 TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF01 TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SIGNALING LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information -'FAD ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Mm ANA Fit P MMS9 M A0 I wmru REGISTERED Made In U.S.A. - Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 Space Age Electronics, Inc. www.Isae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! /?SPACE AGE EL'ELECTRONICS INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector Key Ring Hooks Business Card Holder 0 property intonation Minin,un, Required Documentation (SIC-FUN) ut Certifications and Approvals 16.1 System Installation Contraclo,. Fuv .--a .vnEs1c,,2 a 2t Lo,___________________________ fl. .ntem 6' ,e.O5S na,5 r..S.62*.kd.S uadaanagu.IoFma,sac,cuur.am 4 S,q(am.ama.th,u.th.,ai,noJ,.o!,vha,a,,m.k.. 5- 750525400 En*5,0WthtaId40te.,0 1.1 At 16.5 Auihvrity Hcvirrg Jai2diviivrr '='=-•- 52054 55 .c.ass.5400055 50557.6.6 654 7.6.2 _______ #405455,au ee52ano.2 Equipment Info,matlen 127.ccd1.,.oatlda,ug, .r S254. 1, StCS24206SR52d sate,, 56201524 em-ate-rn, ,00,ul,a,.cco .070644 0.4.1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description L'SSU00685 Fire Alarm Storage Cabinet RED 0 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 L110559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-055320-110 , Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 4854740 Email: bobs@lsae.com DESIGN: Models 1C2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1VIG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FCPS-24S6(CIE) & FCPS- 24S8(CIE) 6- & 8-Amp 24-Volt Remote Power SuL General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAG) expansion (to support ADA requirements and NAG synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FGPS-24S6/-24S8 provides regulated and filtered 24 VDG power to four notification appliance circuits configured as either four Glass B (Style Y) or Glass A (Style Z, with ZNAG-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FGPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FGPS-24S6G & FGPS-24S8G are ULG-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAG synchronization using System Sensor, Wheelock, or Gentex "Gommander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAG expander mode) or jumped perma- nently "ON" (stand-alone mode). Four Glass B (Style Y) or four Glass A (Style Z, with ZNAG-4 module) NAGs. 6-amp (FGPS-2456) or 8-amp (FGPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 4-amp (FGPS-24S6) or 6-amp (FGPS-24S8) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-G normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AG trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated NAG power). Requires input trigger voltage of 9 - 32 VDG. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). DN-6927:A2 EMOT1 F1 E R' by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FGPS-24S6G/-2458G: 120 VAC, 60 Hz, 3.2A maximum. FGPS-2456E/-2458E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDG. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDG. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDG filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FGPS-2456: 4.0 A maximum. - FGPS-2458: 6.0 A maximum. Total short-term current for all outputs (NAG expander mode): - FGPS-24S6: 6.0 A maximum. - FGPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. DN-6927:A2 • 5/17/13 - Page 1 of 2 Float-charge voltage: 27.6 VDC. Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-2458). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-2458 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-2458 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-24S8 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator' mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-24S8 comply with the following standards: NFPA 72 National Fire Alarm Code. IlL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-2456C & FCPS-24S8C) CSFM Approved: 1316-0028:225 MEA: 299-02-E - - FM Approved Ordering Information rFCPS24S6: 6.0 A, 120 VAC remote charger power supply. "IncIudes main printed circuit board, transformers, enclosure '(15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions: FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-2456 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I _I_ We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6927:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 731570028:0225 Page 1 of 1 CATEGORY: - 7315 -- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-03K1< This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division DN-6820:B • D-123 P111:111 80 Character Liquid Crystal Display by Honeywell Annuncit'ö] The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the EIA-485 termi- nal port of each FACP. The FDU-80 requires no programming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - FDU-80 connects to the ter- minal porton the FACP. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188' (5.556 cm) minimum deep, three-gang electrical box (NOTIFIER PN 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER PN SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate system status, and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188' (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. 6820fdu8.jpg Ordering Information 5_6 U-80: 80 character, backlit, LCD Fire Annunciator with con- troI switches for remote control of system functions, and key-, switch lock.. FDU-80C: ULC-listed version; see DN-60573 for details. 10103: Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 MEA Listed: 245-00-E FDNY: COA#6038 eCSFM7120-0028:209- FM Approved NOTE: For ULC-listed version, see DN-60573. ON-6820:B • 05/17/2010 -Page 1 of 2 NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. lIffi&MANIFC1lRlNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6820:13 • 05/1712010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0020209) Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FDU-80 and *FDu..80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. NOTE: *Rev. 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct PV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NBG-1 2LX DN-6726:D • Addressable Manual Pull Station N OTO F1 E R® by Honeywell General -- 1 The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4(10.16cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location k FULIL- L ' - The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScan® systems, 1 - 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D • 4/13/2012 - Page 1 of 2 4 (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-1 2LXSP: Spanish/English labelled version. NBG-1 2LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. ULIULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. fj CSFMö028OT ' FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. :97TWITM, We cannot cover all specific applications or anticipate all requirements. M1111111113INC &MANIMCTIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6726:D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199" Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO, NBG-12L0B, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-I2LWP, NBG-12L, NBG-I2LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-125 are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG-12LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60977:A FSP.951 Series Intelligent Plug-In Photoelectric I-1Y?i I(.]j.: Hon eywellA frtit-ti The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features New modern profile for improved aesthetics. Designed to meet UL268 7th Edition. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan sys- tems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Expanded color options. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0° (5.3 cm) high; base determines diameter. - B300-6: 6.1° (15.6 cm) diameter. - B501: 4° (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.40z (96.4g) Operating Temperature range: FSP-951, 0°C to 50°C (32°F to 122°F). FSP-951T, 0°C to 38°C (32°F to 100°F). FSP-951 in B300-6 Base FSP-951R installed in a DNR/DNRW, -20°C to 70°C (-4°F to 158-F). IJL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at system sensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 2001JA @ 24VDC (one communica- tion every five seconds with LED enabled). LED Current (max.): 4.5mA @ 24 VDC ("ON"). Installation FSP-951 series plug-in detectors use a separate base to simplify installation, service, and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5,' (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60977:A • 4/17/18 - Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document. In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listed: S911 FM Approved FM: 7272-0028:0503 Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. "A" suffix indicates ULC Listed model. "IV" suffix indicates FlashScan@ and CLIP device. FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- can only. FSP-951A: Same as FSP-951 but with ULC listing. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. FSP-951 A-IV: Same as FSP-951 -IV but with ULC listing. FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only. FSP-951TA: Same as FSP-951T but with ULC listing. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device. B224B1-WH: White, isolator detector base. B224B1-IV: Ivory isolator detector base. B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. B200SR-WH: White, Intelligent sounder base capable of producing TFSP951 R White, dow-profile intelligent photoelectric sensor,' sound output with ANSI Temporal 3 or continuous tone. Intended for remote test capable. For use wittftNR/DNRW. FlashScan only.' retrofit applications. FSP-951 RA: Same as FSP-951 R but with ULC listing. For use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA. sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FSP-951 RA-IV: Same as FSP-951 R-IV but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6" base, standard flanged low-profile mounting base. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV: lvory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base. 10% with a square wave or its equivalent; designed to meet the 13300A-6: Same as B300-6, ULC listed. NFPA 72 sleeping space requirement. Intended for retrofit applica- B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, tions. ULC listed. MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6, package contains 10 TR300: White, replacement flange for B21OLP(A) base. B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B21OLP(A) base. base. UL/ULC listed. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501-BL: Black, 4" standard European flangeless mounting base. U.S. single-gang electrical box. For use with B501 (A) and B300(A)- UL/ULC listed. 6. B501-IV: Ivory color, 4" standard European flangeless mounting M02-04-00: Test magnet. base. UL/ULC listed. M02-09-00: Test magnet with telescoping handle. B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. Page 2 of 3— DN-60977:A • 4/17/18 B200SRA-WI-I: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 0001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 93 All All specifications are subject to change without notice. I I ENGINHING & MANI1A1UBIN QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-60977:A • 4/17/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. -002j0563 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FSP-951, FSP-951R, FSP-951T, FSP-9511-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-9511, FSP-9511-ISO and NP-200T have complementary heat detectors. All models are simitarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B71OLP (CSFM No. 7300-0028:0173); System Sensor Models *13224131 *B224RB (CSFM No. 7300-1653:0126); 13200S, B200SR (CSFM No. 7300-1653:0213); 13200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *132101-P 13300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM No. 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60975:A FST-951 Series Intelligent Thermal (Heat) Detectors by Honeywell The NOTIFIER FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and build- ing design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135°F/ 57°C fixed-temperature, rate-of-rise and a 180°F/88°C fixed high- temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as desig- nated. Features Sleek and stylish contemporary design. Advanced thermal technology for fast response. Fixed temperature model (FST-951) factory preset to 135°F (57°C). Rate-of-rise model (FST-951 R), 15°F (8.3°C) per minute. High temperature model (FST-951H) factory preset to 190°F (88°C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Two-wire SLC connection. Visible LEDs "blink" every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (two bi- color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identification. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and mainte- nance. SEMS screws for wiring of the separate base. Optional remote, single-gang LED accessory. Optional sounder, relay, and isolator bases. Specifications Size: 2.0" (5.3 cm) high; base determines diameter. - B300-6: 6.1° (15.6 cm) diameter. - B501: 4° (10.2 cm) diameter. For a complete list of detector bases, see DN-6098 1 Shipping weight: 3.40z (96.4g) Operating temperature range: FST-951, FST-951 R Series: —20°C to 38°C (-4°F to 100°F); FST-951H Series: —20°C to 66°C (-4°F to 150°F). FST-951 R in B300-6 Base Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% non-condensing. Thermal ratings: Fixed-temperature set point 57°C (135°F), rate-of- rise detection 8.3°C (15°F) per minute, high temperature heat 88°C (190° F). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 200uA @ 24 VDC (one communica- tion every 5 seconds with LED enabled). LED current (max.): 4.5mA @ 24 VDC ("ON"). Applications Use thermal detectors for protection of property. For further informa- tion, refer to 156-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Installation The FST-951 Series plug-in intelligent thermal detectors use a sepa- rate base to simplify installation, service, and maintenance. Installa- tion instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60975:A • 4/23/18— Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document.ln some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listing: S2101 FM Approved ZM: 7270-0028:050k Product Line Information NOTE: "A" suffix indicates ULC Listed model. NOTE: "-IV" suffix indicates FlashScanO and CLIP device. ST-951 White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only. FST-951A: Same as FST-951 but with ULC listing. FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. FST-951A-IV: Same as FST-951-IV but with ULC listing. FST-951R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only. FST-951 RA: Same as FST-951 R but with ULC listing. FST-951 R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, FlashScan and CLIP. FST-951 RA-IV: Same as FST-951 R-IV but with ULC listing. FST-951 H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only. FST-951 HA: Same as FST-951 H but with ULC listing. FST-951 H-tV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP. FST-951 HA-IV: Same as FST-951 H-IV but with ULC listing. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 13300-6: White, 6" base, standard flanged low-profile mounting base. B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. B300A-6: Same as 6300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4° standard European flangeless mounting base. ULJULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. B501-WHITE-BP: Bulk pack of 6501 -WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. B224B1-IV: Ivory isolator detector base. B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with 6501 (A) and B3006(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN-60975:A • 4/23/18 - Page 2 of 3 Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. Notifier® and Bayblend® is a registered trademark of Bayer Corp. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. S O9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I 93 All All specifications are subject to change without notice. I U ENGINFRUIR & MNFAC1KRIN QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-60975:A • 4/23/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. r727O-OOO2 Page 1 of 1 CATEGORY: 7270-- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models FST-951, FST-951H, NH-200, NH-200H (fixed temperature) and FST-951R, NH-200R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-951 and NH-200 (fixed temperature): 135°F. Models FST-951H and NH-200H (fixed temperature): 190°F. Models FST-951R, NH-200R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM No. 7300-0028:173); System Sensor bases 13501, 132I01-P, B300-6, B300-6-IS (CSFM No. 7300-1653:0109); B224B1, B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); 13200S-LF, B200SR-LF (CSFM No. 7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6720:E FMM.l (A), FMM-1 01(A), FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan® by Honeywell I EA1.i.i General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM-1(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E •07/30/2015 - Page 1 of 4 FMM.1 01 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 1415 0 1 ADDRESS I 0 1 11 LOOP 10 8 76 8 76 TENS ONES II IIi II I oIl 11w .0 jII Uj -iII 10 •— H I .00 The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1 (A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120'F (0°C to 49°C). Page 2 of 4— DN-6720:E • 07/30/2015 Humidity range: 10% to 93% noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125" (5.398 cm) deep box. tory for latest listing status. FDM-1 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) lDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. UL: S635. ULC: S635. FM Approved. 'CFM: 73028:0219,7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, N FS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. c:101(A):onitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM.1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. DN-6720:E . 07/30/2015 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatch is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. g We cannot cover all specific applications or anticipate all requirements. MCINERINS &*MMCflHC QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-6720:E •07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. c70-0028:0219' Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6724:B3 FCM.1(A) & FRM.1(A) NOT I FIER® Series Control and Relay Modules - by Honeywell L General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style V or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and Til): Maximum (NAG): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAG Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125' (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 iJA direct poll; 255 IJA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25' (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM-1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (LIR=5ms) 1 A 30 VDC Inductive Coded (LIR=2ms) .3A 125 VAC Inductive (PF=0.35) Non-Coded Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. BM1(A):In,telligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document /56-1169. FRM-1(A) Installation document /56-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. :bd I I .1 We cannot cover all specific applications or anticipate all requirements. 13111111101111119 &MANITACIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com p Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (00-0628:0219_\ Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneyweU.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division llrrov aL/il The InnovairFIex Series DNR and DNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFiex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexility and installation ease. These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the DNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, lain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money. The lnnovairFlex housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover.The housing also provides a 1/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring. f - Svs iiE/JIII Intelligent Non-Relay Photoelectric Duct Smoke Detector The Inn ovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology (detector head sold separately) Air velocity rating from 100 ft/min to 4,000 ft/mm Adjusts to square and rectangular mounting configurations Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented tool-free, plug-in sampling tubes New cover tamper signal Increased wiring space with a new 3/4-inch conduit knockout Housing has space for mounting a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires corn line power only NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) UV-resistant, UL-listed housing and cover material (DNRW only) The InnovairFiex line is compatible with all previous Innovair models, including remote test accessories, for easy retrofits. WARNING: Duct smoke detectors have specific limitations. Agency Listings MSFM LISTED APPROVED approved 2911 3029700 a, 2125 InnovairFiex Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex°°' DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRWWatertight NEMA 4 Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems.The flexible housing of the duct smoke detector fits both square and rectangular footprints.The detector shall operate at air velocities of 100 ft/min to 4,000 ft/mm (0.5 rn/sec to 20.32 m/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 25 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA 4 (DNRW only) Operating Temperature Range: —4°F to 158°F (-20°C to 70°C) Storage Temperature Range: —22°F to 158°F (-30°C to 70° C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/mm (0.5 to 20.32 m/s) DCOIL (if included): 17.5— 26.4 VDC, 95 mA max .1 Please see detector head installation manual for electrical specifications - Device Standby Alarm RA100Z OmA 12mAMax. RTS151/RTS151 KEY 0 mA 12 mA Max. Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). P A05-0422-OOS Wiring for Intelligent Non-Relay Duct Smoke Detector System wiring diagram for DNR: COMM. I LINE I COMM. LINE I I _ LINE COMM. I 1ST 2ND UL/FM LISTED CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP DNR to RA1 OOZ: RA100Z REMOTE ALARM LED OPTION 1 PER UNIT DNR to RTS1 S1/RTS1 Si KEY with "R" Remote Test Capable Detector Head Option: TEST COIL + TEST COIL — RTS151/RTS151KEY COMM+ OUT (CONV ONLY) + 2 COMM— L -[ 3 JUMPER RA/RTS— RTS+ DNR to RTS1 51/R1S151 KEY with DCOIL Option*: TEST COIL + XTERNAL TEST COIL— __.cIIIII1__. COMM + OUT (CONV ONLY) + comm — RTS151/RTS151KEY 7 REMOTE TEST STATION RA/RTS — LED OPTION RA+ 1 PER UNIT RTS + TEST COIL OPTION 1 PER UNIT 95 mA CURRENT DRAW important Notes The use of either the RTS1 51 or RTS1 51 KEY requires the installation of an accessory cod, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. The RTS1 51/RTS1 51 KEY test coil circuit requires an external 24VDC power supply which must be UL listed. A 05 .04 2 2-005 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. _ LII RTS1 51 UL 52522 RTS1 51 KEY ULS2522 RA100Z UL 52522 Ordering Information .1 1ntel5gentnonrelayphotoeIectrkiow-fiow ductsmc4etectot. DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector Accessories DCOIL Remote test coil required with ETX Metal exhaust tube duct width 1 ft (0.3 m) RTS451/RTS451KEY/RTS151/RTS151 KEY DST1 Metal sampling tube duct width up to 1 f (0.3m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 24 m) DSTI 0 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) P48-21-00 End cap for metal sampling tubes M02-04-00 Test magnet RA1 OOZ Remote annunciator alarm LED RTS1 51 Remote test station RTS1 51 KEY Remote test station with key lock DH4000E-1 Weatherproof enclosure 02010 System Sensoir, 3825 Ohio Avenue. St. Charles, IL 60174 Prodtict specifications sLjbject to change vVifl-it notice Visit swernsensorcorn for ciifrent product infc-a "cluding the latest version of this data sheet Phone: 800-SENSOR2• Fax: 630-377-6495 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL r Y7 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 4 LISTING SERVICE LISTING No. p-165-3:0209 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division !STE Indoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. - Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Agency Listings SIGNALING OQ. LISTED S5512 PM approved except 7125-15530504 S4011 for At_OPT models 3057383. 3057072 - The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The [-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the [-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. [-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185 Strobe The strobe shall be a System Sensor [-Series Model listed to U[ 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1'2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6" [ x 4.7"W x 1.91" D (143 mm [ x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" [x 3.46" W x 1.91" D (133 mm [x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D (143 mm [ x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" [x 3.45W x 1.25" D (133mm Lx 88mm W x 32mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 Cd and 30 cd. UL Current Draw Data I I 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 .. :.. 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input l5cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data _ 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes Horn 19 L-Series Dimensions 1.91 3.46 5.27 1.25 110010", ON Is. LL9 Compact Strobe! Horn Strobe —3.46 —] .27 1.25 00 0.0000.0 000000000000 00* Compact Horn L-Series Ordering Information Wall Horn Strobes P2RL 2-WireWorn Strobe,Red 2Wire, Horn Strobe, Whit& P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no FIRE" marking on cover) All -SF models have "FUEGO" marking on cover All -ALERT models have "ALERT" marking on cover sysFam 3825 Ohio Avenue • St. Charles, IL 60174 sysew Sensor. for current product information, including the latest nerson of this data sheet. Phone 800-SENSOR2 • Fax 630-377-6495 Product specilicatoos subject to change without notice. Visit systersserrsor.corn www.systemsensor.com AvDs86503 • 03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 71135-16530503' Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and *TR2W Ceilinglrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5 VY FEM SEinsco® Indoor Selectable. Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlerf and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNALING & 0 LISTED A1111111111 S5512 FM approve J except 1ZS1609 S4011 for ALERT models fn54WA503 3057383 Th \ 4~N /. k\ iZ The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor [-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the [-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, [-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize [-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. . .. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Ranqe 10 to 93% non-condensina Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (F\NR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, S. PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 1115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lK Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data F tLL 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temooral Low 77 83 83 AVDS86800 I 2.47 1.37 06.r 4 tv L-Series Dimensions Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information ____ ____ • Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red mPCWL Wire Horn Strobe,White Ma j] Ceiling Strobes SCRL Strobe, Red .SCWL StrobeWhitei SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 020 7 Syr,em Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to1 change withoutnotice. Volt systensensor.corc Phone: 800-SENSOR2 • Fax: 630-377-6495 for current p'oduct information, ,rrcludng the latest nero on of Nis data sheet. AVDS86801 • 03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL m FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1653:0503 Page 1 of 2 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneyweIt.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PT, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Pvt operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL [In FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 735-16530504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W Ceilinglrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Pvt operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division