HomeMy WebLinkAbout2548 CAMPBELL PL; ; FPC2020-0090; Permit(City of PERMIT REPORT Carlsbad Print Date: 03/31/2022 Permit No: FPC2020-0090 Job Address: 2548 CAMPBELL PL, CARLSBAD, CA 92009-1700 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132611700 Track #: Applied: 05/14/2020 Valuation: $1,813,890.00 Lot #: Issued: 05/29/2020 Occupancy Group: Project #: Finaled Close Out: 09/14/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASAT N4 -ADD/RELOCATE SPRINKLERS (339 HEADS) & DISCONNECT EXISTING PRE-ACTION SYSTEM FROM REMOVED SERVE ROOM & EXTEND SYSTEM SUPPLY TO NEW ROOM 1.076 & 2.088 Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System > 100 heads $654.00 Total Fees: $813.00 Total Payments To Date: $813.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 19c2olc) 009O TANL Ek M FIRg PnorccYloN Fire Protection Contractor - License #989280 FIRE SUPPRESSION HYDRAULIC CALCULATIONS 20135 ViaSat N4 T.I. 2548 CAMPBELL PLACE Carlsbad, CA 92009 No. 223 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Viasat Bldg, N4 T.I. SR#: (Assigned upon plan submittal) PROJECT ADDRESS: CITY: Carlsbad PHONE: ( 760) 295-3436 (Titan Fire Protection) FAX NUMBER: (760) 295-3437 Largest Building (ft.2): 39,000 Sprinkled? Yes Construction Type: Ill-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Northeast corner of Campbell Place TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 94 PSI Hydrant Number (if applicable):H61732 & H61728 Elevation of test: 333 Feet Main Size: 10 INCH Pressure Zone: 550 Feet Date/Time of Test: Pitot Tube Reading: PS 1, Corresponding Flow: GPM Total Flow: 3,200 GPM Residual Pressure82 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this exceeds the City's maximum velocity criteria. The fire flow that meets both velocity and pressure criteria is 3,200 gpm. Based on the building square footage and construction type provided, the building would require a fire flow of 4,250 gpm for 4 hours, without any reduction for sprinklers applied. This fire would result in a pressure of 31 psi and a velocity of 13.0 fps. All flows were split between the two hydrants shown. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable):C69606 Signature: wr Title/Org: P je Manakc' Date: 05/06/2020 4 12" PALOMAR AIRPORT RD 10" eig 12" 4 Fire Flow Test Legend Location H61732 4 w_Hydrant Pipe N ZONE 550 700 Fire Flow Test ocionH61728 12" 12" 12" GATEWAYRD 12" 12" 12" .3- tc I 8"DISCOVERYRIC U L LI 11111 - J - !NGLETONAV #223 Viasat Bldg N4 Ti. -Fire Flow Analysis May 18, 2009 EXISTING, FOR HYDRAULIC CALCULATIONS REFERENCE ONLY. 2-1/2" MODEL F SERIES \j I 1(1 STRAIG GE TH DELU ROUGH - ' FRICTION LOSS CHART The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com FOR USE WITH ENGLISH PRACTICAL SYSTEM Where Flow is Measured in GPM and Pressure is Measured in PSI Graph is for reference purposes. 9 .-----H-- -H. --+--- ••- ....-- .--+-.. -4----H - --4- -.. - - -. -- 4-- .- ----.-..4-----±----- .-4 - -- .--- --- - ___- --- 4-- --- -4----------- t ---- -- ----- -- --- -- - ----- - __- - - - - --- - --- -- 8 --- - - - L -I- .---4----- h---- .- ....------t--...H-.....-'-------4-...._---....-1-_-----4-- -_-_-+-__-------- -- ----H -----4------- --------- -------- -- --4-- - --*----- -- . ------- ,- --4- --- -4---- - ---------- - --------- - ------------- -4- ---- -------,-----4------....±----- ---- -- -- --- - ---4- .. - 6 ---- -- - ------.- -- ---4 ----- - --- -- --4--- -- ----- --+ - ---- ----------- ----t- - -- -4-- -----4-- ---- +----- - -1------*--__ H- -----4------- ---__- -_-_ +---- -4- _-. --- -- 0. E IEIIII U) U) 5 --- -4----, ------ -4- ---4--- '- f ------4-t fH H ---- ..-1--- ---p-- --h-----------4- .-H----- -1---..---1-----------1---------1---- - -4---- ----------- - ----i--- - --- --- - -I ---- __+ -- - --- -----€- ---- 4---- ,- --------- ---1- - ----------1- -- 4----- - ---' --4- --4-- -1- -- 4-- C 4- -4--- 4 -- ---------4- --- ----------4 -- -4-_. .-4-----.4- 4------4----_--4----....----+---.-5 4---4------ I ---------- - -. I.- 4 - -- - — -------------- U - -- .---- - - - - --- -- ----- --- ----- — - - 4- --- -- - ---- - •- - LL - ' 4---- 4- -- -H------±--------------- -- --------------*---- - - .' --4--------.-- -----4------- -- _________4-_____ -4-- 4-- ----1--..-------- --4-------------- p-- - --4---------4-- ----4-----------4--- -- -------4-------4- --- -4-. 3 --- 4--- -- ------4---- -I ------1---- -'- ----- -- ,-- ------4---------1 -----'-- ---. ------ --4----- --. ----I----- 4- -- - - 4-- -- --- - ---- ----------- - ---- -----:---- -- ----4--------- ------ --- 4--..-4-..--4----...-4..- ------ -- ------- . - 2 ------ ---4 --__ --- __ - 75 125 175 225 275 325 375 425 475 --W-Total PSI Loss 0.28 0.72 1.34 2.13 3.08 4.20 5.47 6.90 8.48 Flow in GPM (C = 120) Friction Loss for the 2-112" Viking F Series Straight Through Deluge Valves is equivalent to 12 feet of 2-112" Schedule 40 (Id = 2.469") Pipe (C = 120). To calculate friction toss for the 2-112" (id = 2.469") Viking Model F Series Straight Through Deluge Valves at a specific flow, use the following formula: 4.52 x 01,65 P = (C x 2.469w ) x 12 Psi Where P = Friction Loss (PSI) Q = Flow in GPM C = Constant (=120) Form No. F052009 New friction loss chart, issued May 18, 2009. EXISTING. FOR HYDRAULIC CALCULATIONS REFERENCE ONLY. odeI ©AL\ Double Check Detector Assembly Application Designed for installation on water lines in fire protection sys- tems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350ADA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Horizontal & Vertical) ASSE® Listed 1048 AWWA Compliant C510 (with gates only), and C550 CSA® Certified B64.5 UL® Classified C-UL® Classified FM® Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA221-04M-2 (2 1/2" -8") Meets the requirements of NSF/ANSI 61* (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backflow Assembly 3/4" Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved electrostatic epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners & Springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Features Sizes: 2 1/2*, 3"° , 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged bolt pattern) ASME 1316.42 Class 150 *2 1/2" & 3" sizes use 4" body & reducer couplings Dimensions & Weights (do not include pkg.) MODEL 350ADA SIZE in. I mm WEIGHT LESS SHUTOFF VALVES lbs. I kg OSY GATE VALVES FLANGED lbs. I kg OSY GATE VALVES GROOVED lbs. kg BUTTERFLY VALVES FLANGED lbs. I kg BUTTERFLY VALVES GROOVED lbs. I kg 21/2 65 105 48 192 87 184 83 157 71 147 67 3 80 104 47 210 95 200 91 162 73 148 67 4 100 91 41 230 104 204 93 147 66 139 63 6 150 141 64 362 164 332 151 246 111 215 98 8 200 302 137 762 346 738 335 491 223 445 202 10 250 355 161 1024 464 902 409 628 285 570 259 LEAD FREE US NSF/ANSI 61 (with OS&Y gates) (with BG valves) Options (Suffixes can be combined) LI - with flanged end OS & Y gate valves (standard) LI L - less shut-off valves (grooved body connections) LI LM - less water meter - with gallon meter (standard) CFM - with cu ft meter O CMM - with cu meter meter 0 G - with grooved end connections LI FG - with flanged inlet connection and grooved outlet connection 0 P1 - with Post Indicator Gate Valves BG - with grooved end butterfly valves with integral supervisory switches BF - with flanged end butterfly valves with integral supervisory switches Accessories Repair kit (rubber only) O Thermal expansion tank (Model XT) LI OS & Y Gate valve tamper switch (OSY-40) j 11 I B I MODEL 350ADA with OS&Y option I1tI;It± MODEL 350ADA with BG option MODEL DIMENSION (approximate) 350ADA SIZE in mm A in I mm A WITH BUTTERFLY VALVES in I mm B LESS GATE VALVES in mm C in mm D in mm E OS&Y OPEN in I mm E OS&Y CLOSED in mm E WITH BUTTERFLY VALVES in mm F in I mm G in mm 21/2 65 351/81 892 321/8 816 20 1/8 511 41/2 114 9 229 173/4 451 153/8 391 17 432 6 152 71/4 184 3 80 361/8 918 33 838 20 1/8 511 41/2 114 9 229 201/4 514 17 432 17 432 6 152 71/4 184 4 100 381/41 972 331/4 845 197/8 505 41/2 1/2 572 18 1/4 464 17 432 6 152 8 203 6 150 47 1/4 1200 40 1/4 1022 257/8 657 51/2 M24 1/2 775 24 1/4 616 171/2 445 7 178 10 254 8 200 62 1575 55 1397 38 1/2 978 10 7 940 28 1/2 724 1615/16. 430 81/2 216 11 279 10 250 645/8 1641 59 1499 381/2 978 10 5/8 1159 343/4 883 1615/16 430 81/2 216 12 305 Attention: Model 350ADA (grooved body) and Model 350DA (flange body) have different lay lengths. Zurn Industries, LLC I Wilkins Rev. L Date: 3/20 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Document No. BF-35OADA In Canada I Zurn Industries Limited Patent No. 5, 913, 331 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 Product No. Model 350ADA www.zurn.com Page 1 of 2 Flow Characteristics MODEL 350ADA 2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (Vs) 0.0 12.6 25.2 37.9 15 0. (0 U) 10 —j Ui IM 5 1/2 104 - EI69 0 CL t5 cc 3000 CRated Flow (established by approval agencies) 50.5 104 ig wo 69 LU 35 w Cr 0 0 U. 0 200 400 600 800 FLOW RATES (GPM) MODEL 350ADA 6",8" & 10" (STANDARD & METRIC) FLOW RATES (us) 0.0 63.1 126.2 189.3 252.4 2 15 U) - q, 10 0 —j I 1000 2000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. MODEL 350ADABG (Vertical Installation) Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 21/2 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8' 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1 1763 2644 3525 5288 PROTECTIVE MODEL 350ADA (Outdoor Installation) Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and sup- plied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 350ADA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario 1_6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 20135 - ViaSat Bldg N4_FPDesign Building : FP3 Location : 2548 CAMPBELL PLACE System Area I Contract : 20135 Data File : 20135 - ViaSat Bldg N4_FPDesign Area I .WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - TITAN FIRE PROTECTION, INC. Page 20135 - ViaSat Bldg N4_FPDesign Date HYDRAULIC CALCULATIONS for Project name: VIASAT N4 Location: 2548 CAMPBELL PLACE Drawing no: FP3 Date: 5-13-20 Design Remote area number: Area I Remote area location: IDF - LEVEL 2 PREACTION Occupancy classification: OH 1 Density: .15 - Gpm/SqFt Area of application: 156 - SqFt Coverage per sprinkler: 130 MAX - SqFt Type of sprinklers calculated: SSP Q.R. K5.6 No. of sprinklers calculated: 2 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 289.159 -GPM Type of system: WET Volume of dry orpreaction system: N/A - Gal Water supply information Date: 5-06-20 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: TITAN FIRE PROTECTION Address: 2880 SCOTT ST. Phone number: 760-295-3436 Name of designer: M. Marron Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) @ 51.82-Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 20135 - ViaSat Bldg N4_FPDesign Date City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 10.178 C2 - Residual Pressure: 72.6 D2 - System Flow : 39.159 C2 - Residual Flow : 3200 D2 - System Pressure : 51.828 Hose ( Demand) : 250 D3 - System Demand :289.159 Safety Margin : 32.631 150 140 130 120 R° E10° s 90 CI 80 - ____________ C2 U 70 R6° E5° D 40 30 20 10 • DI ...I I I I I I I 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 3 20135 - ViaSat Bldg N4_FPDesign Date Fitting Legend Abbrev. Name 1/2 ¼ 1 1¼ 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zic Wilkins 350ADA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. 20135 - ViaSat Bldg N4_FPDesign Page 4 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 23.5 5.6 12.13 na 19.5 0.15 130 7.0 2 25.5 12.81 na 3 25.0 13.25 na Ml 25.0 15.86 na M2 25.0 18.16 na PC 25.0 27.35 na M3 10.0 36.83 na M4 1.0 44.83 na BOR 1.0 44.84 na UG1 1.0 44.86 na BF1 1.0 44.87 na BF2 1.0 51.39 na UG2 1.0 51.39 na TEST 0.0 51.83 na 250.0 8 23.5 5.6 12.32 na 19.66 0.15 130 7.0 The maximum velocity is 7.69 and it occurs in the pipe between nodes 3 and Ml Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 20135 - ViaSat Bldg N4_FPDesign Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 19.50 1.049 2E 2.855 2.500 12.125 K Factor 5.60 to 100.0 T 3.568 6.423 -0.866 2 19.5 0.1740 0.0 8.923 1.553 Vel = 7.24 2 0.0 1.442 0.0 6.000 12.812 to 100.0 0.0 0.0 0.217 3 19.5 0.0368 0.0 6.000 0.221 Vel = 3.83 3 19.66 1.442 2E 4.282 15.200 13.250 to 100.0 0.0 4.282 0.0 Ml 39.16 0.1342 0.0 19.482 2.614 Vel = 7.69 Ml 0.0 1.442 E 2.141 15.000 15.864 to 100.0 0.0 2.141 0.0 M2 39.16 0.1342 0.0 17.141 2.300 Vel = 7.69 M2 0.0 1.442 3E 6.423 57.720 18.164 to 100.0 T 4.282 10.705 0.0 PC 39.16 0.1342 0.0 68.425 9.182 Vel = 7.69 PC 0.0 2.157 3E 10.705 147.670 27.346 to 100.0 0.0 10.705 6.496 M3 39.16 0.0189 0.0 158.375 2.991 Vel = 3.44 M3 0.0 2.635 E 4.282 9.000 36.833 to 100.0 0.0 4.282 7.898 * * Fixed Loss = 4 M4 39.16 0.0071 0.0 13.282 0.094 Vel = 2.30 M4 0.0 2.635 0.0 3.610 44.825 to 120.0 0.0 0.0 0.0 BOR 39.16 0.0053 0.0 3.610 0.019 Vel = 2.30 BOR 0.0 4.1 2E 26.6 7.000 44.844 to 140.0 0.0 26.600 0.0 UGI 39.16 0.0004 0.0 33.600 0.014 Vel = 0.95 UGI 0.0 5.86 2E 42.31 63.000 44.858 to 150.0 0.0 42.310 0.0 BFI 39.16 0.0001 0.0 105.310 0.008 Vel = 0.47 BFI 0.0 6.16 4E 74.48 12.000 44.866 to 140.0 Zic 0.0 74.480 6.520 * * Fixed Loss = 6.52 BF2 39.16 0.0001 0.0 86.480 0.005 Vel = 0.42 BF2 0.0 5.86 T 45.332 12.000 51.391 to 150.0 G 4.533 49.865 0.0 UG2 39.16 0.0001 0.0 61.865 0.004 Vel = 0.47 UG2 0.0 9.42 0.0 23.000 51.395 to 150.0 0.0 0.0 0.433 TEST 39.16 0.0 0.0 23.000 0.0 Vel = 0.18 250.00 Qa = 250.00 289.16 51.828 KFactor= 40.17 8 19.66 1.049 2E 2.855 2.500 12.324 K Factor = 5.60 to 100.0 T 3.568 6.423 -0.650 3 19.66 0.1766 0.0 8.923 1.576 Vel = 7.30 0.0 19.66 -13.250 KFactor= 5.40 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A C11TAN PIRU PROTUCYtON F rc- 2o7,o 0090 Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 20135 ViaSat N4 Ti. 2548 CAMPBELL PLACE Carlsbad, CA 92009 Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage5 Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth cellingi I desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and rein5talled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated In the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 ztWARNING: Cancer and Reproductive Harm. www.P65Wamnings.c9gov () VdS Approved: Certificate G4080021 LPCB Approved: Certificate number 096e/12 CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-Cl 9500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND "t1II(iNG QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-Cl 1000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-ClI000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 OF (68 °C) = B, 175 OF (79 "C) = D, 200 OF (93 "C) = E For example, sprinkler VK463 with a 155 OF (68 "C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-M, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 OF (57 "C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 165 OF (74 "C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 OF (57 "C) UL (139 OF (59 °C) FM and LPCB) = A, 165 OF (74 "C) = C For example, cover 21876 with a 165 OF (74 °C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 "F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2 ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT '1 I FJ 4 l:II[• ' SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269445.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE ISPRINKLER TEMPERATURE RATINGS ANDIllFI:l* Sprinkler Sprinkler Maximum Nominal Ambient Temperature Rating of Cover Cover Plate Large Cover Square Cover Temperature Temperature Ceiling Assembly (Required) Base Part Plate Base Part Plate Base Part Bulb Colo Classification Rating' Temperature Number' Number' Number3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135 °F (57 °C) cULus 13504 or 21876 5 13642 or 218751 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 13504 or 21876111 642 or 21875 15394 Yellow Intermediate 200 °F (93° C) 150 °F (65° C) 165 °F (74 °C) 13504 or 21876 5 113642 or 218755 15394 Green Cover Plate Finishes5: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings": ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly, 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 MIRAGE STANDARD AND l:II[.q..1uqM QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 2699459501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) I SprinklerTemperature Rating JCover Rate Temperature Ratng Mirage® Concealed Pendent Sprinklers VK462 and VK463 AW1- Cover Plate Finish KEY Sprinkler Thread Nominal Maximum Listings and Approval54 SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' I Inch mm U.S. metric2 Pressure cULus' I NYC VdS7 LPCB CE 1 1 Standard Response Applications 13503A VK462 1/2" -- 5.6 80.6 175 psi (12 bar) - -- AY1, CZ1 AYI, BZ1 AY1,CZ1 AY3 19785A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - - - -- AYZ, CZ2. 21356A VK462 -- 15 5.6 80.6 175 psi (12 bar) - -- - -- - - AY2', CZ2: Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AVI, BX16 - - - AY3 -- AS3, BT3 AV1, BX1, 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX16 - - -- -- -- AS3, BT3 13667A VK463 1/2" 15 5.6 80.6 250psi(17.2bar)3 1 AV1, BX1 I AV1, BX16 - -- -- -. -- Cover Plate Assembly Temperature Ratings19 Sprinkler Temperature S - 135 °F (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishe&° Ratings T - 165 °F (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155°F (68 °C) °F °C) V - 135 (57 cULus Listed cover 13504, 13642 (large diameter), or 15394 (square cover plate) Brass, Brushed Brass, Brushed Copper, Painted White, B - 175 °F (79 °C) and 200 °F x - 165 °F (74 °C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 °C) Y - 135 °F (57 °C) cover 13504 LPCB Approved as 139 °F 2 - Brass C - 200 °F (93 °C) (59 °C) 3 - Stainless Steel Z - 165°F (74 °C) cover 13504 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. tAccepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40249. The 135/139 °F cover has an orange label. The 165°F (74 °C) cover has a white label. ID Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. cULus Listed as corrosion resistant. 2 MED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 5 of 7 MIRAGE® STANDARD AND i1I!i A l:Il[.nu,yay QR CONCEALED PENDENT III SPRINKLER VK462AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Aooroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.10.11 Rev 18.2.P65 Page 6 of 7 NIMIRAGE® STANDARD AND Ill A QR CONCEALED PENDENT • J SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone; 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Sprinkler Temperature Rating I Cover Plate Temperature Rating Miragee Standard Response Concealed Pendent Sprinkler VK462 AWI+ Cover Plate Flntah KEY Sprinkler Base SIN I NPT Thread Size I I Nominal K-Factor I Maximum I FM ApprovaI53 Part No.' I i I Water Working I (Refer also to Design Criteria below.) I Inch I mm I U.S. I metric2 I Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Ratings1'4 Cover Plate Assembly Finishes' Y - 139°F (59 °C) cover 21875 or 21876 Sprinkler Temperature Ratings z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) W- 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175°F (79 °C) and 200 °F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 7 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT I SPRINKLER VK462AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap Sprinkler Wrench removed __ Part No. 14047 WB** Use wrench - -,dc Step 1: Carefully slide the wrench sideways around the deflector and pins 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Sprinkler wrench fla 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum 2-1/16" (52 mm) Minimum AMMER r W—A c4 LO 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 lizxl' MICROFAST® QUICK I lIlEU.7f RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone- 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking webslte for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroles Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation] in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 LPCB Approved: Certificate 096e106 WA1MNO Can= wd Rprodutve cr wPMWnc®4ev CE CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 NJ,,'l I(Ii1G MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W1B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A /" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap - Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 19.02.21 Rev 19.1 Page 3of6 N II(IFI MICROFAST® QUICK 11ilIl[.q..U.LIf RESPONSE PENDENT SPRINKLER VK302 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient I Classification Temperature Rating' Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F(38 °C) Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 OF (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/I for recessed pendent sprinklers ** A 1/2" ratchet is requin (not available from Vikim Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F033314 19.02.21 Rev 19.1 Page 4 of 6 N I I( I I1G ® MICROFAST® QUICK 4 lII[U'YM RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-9459501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY The Viking MicFofastO Quick Response Pendent Sprinkler VK302 AiX - Escutcheon (If appHr.sble) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall lLLt1n95 and Approvals' Part SIN K-Factor Length (R.f.r also to Duign Crftarta,) Number1 Style NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2,C2X Al A1Z,B1Y DIZ,0,11 Y ___DI ____ _______ 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 -- -- -- - - D3 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 - -- -- - - - 7lmI y (Comar t Local viking 06662B I VK302 77777712" 15 mm 1 5.6 1 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X -- -- - - - 18021 1 VK302 I Pendent 1 1/2" 15mm1 5.6 1 80.6 1 2-1/4 —58-T AIX, B1Y Al AIX, B1Y DIX, C1Y7 DI Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 "F (57 °C), 155 °F (68 °C), 175 °F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 °C), 286 "F (141 °C) Polyester56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter-' Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 °C), and 200°F (93 °C) 2- ENT' Model E-1, E-2, or E-3 Recessed Escutcheon C -155 °F (68 °C), 175 °F (79 °C), and 3-Chrome Z- Standard surface-mounted escutcheon 200 °F (93 °C) 0-155 °F (68 °C), 175 °F (79 °C), 200°F (93 °C), 286 °F (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. MED Certified, Standard EN 12259-1, EC-0832-MED-1 003. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast®1 Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 5 of 6 MICROFASTO QUICK RESPONSE PENDENT NJIKI SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 2699459501 Technical Services: 877-384-5464. Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking wobsite for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Micifast® Quick Response nn:sh Pendent Sprinkler VK302 AIX 4— Escutcheon (if am5cbe) Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM: ApprovaIs NPT BSP U.S. metric2 Inches mm Number' Style (Refer also to Design Criteria.) 12979 VK302 I endent 1/2" 1 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 (.J1fP Product Bet LimitedAvailability (Contact 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, 131Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 1 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F X - Standard surface-mounted escutcheon or the (93 °C), 286 °F (141 °C) Approved Finishes Viking Micromatic® Model E-1 Recessed B -135°F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1- Brass, Chrome, White Polyester4, Escutcheon 200 °F (93 °C) and Black Polyester' Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 with the Viking Micromatic® Model E-1 or E-2 °F (141 °C) Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM AeDroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 19.02.21 Rev 19.1 Page 6 of 6 N 1I(II1G® MICROFAST® QUICK 4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum 1/2 (15 mm) 2-1/2" (64 mm) maximum NPT 469 U L4 Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon __ 2-1/8"... (54 mm) ".. J- 1-3/4" (45 mm) Max. - - Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum - (29 mm) 2" Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 1 of 6 N II(It1® MICROMATIC® STANDARD 1II[sUsYM.. RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vIkinggroupinc.com DESCRIPTION The Viking MicromaticP Standard Response Upright VKIOO Sprinkler is a small, thor- mosonsitive, glass-bulb spray sprinkler available in several different finishes and tarn- perature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. in addition, these coatings have been investigated for installation in corrosive atmospheres andl are listed/approved as corrosion resistant as indicated in the Approval Charts. Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions, LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Classes 2001, 2002, 2015, 2017, 2043 WARJI1tG Cncar pni frfwn- NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be foowed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) Glass-bulb fluid temperature rated to -65 OF (-55 "C) Overall Length: 2-3/8" (60 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-CI 9500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-CI 1000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated. ttNot for FM Approval. Ordering information: (Also refer to the current Viking price list,) Order Micromatie Standard Response Upright VKIOO by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F. White Polyester = M/W, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-/W, ENT = JN Temperature Suffix: 135 OF (57 "C) = A. 155 "F (68 "C) = B. 175 OF (79 "C) = D, 200 OF (93 "C) = E, 212 OF (100 "C) = M, 286 OF (141 "C)=G, 360"F(182"C)=H, 500 OF (260"C)= L. For example, sprinkler VKIOO with a 1/2" thread, Brass finish and a 155 OF (68 "C) temperature rating = Part No. 12986A5 Available Finishes And Temperature Ratings: Refer to Table 1. Form No. F_052014 19.10.14 Rev 19.1 Replaces Form No. F052014 Rev 17.1.P65 (Added EN. updated FMl language.) Page 2 of 6 NJ I KJ :'IG® MICROMATIC® STANDARD 4 1$IIEUi7If.. RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877484.5464 Fax: 269418.1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupInc.com Accessories: (Also refer to the Viking website) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B Standard Wrench for Wax Coated Sprinklers Part No 10896W/B (available since 2000) C. Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/8* (available since 2006) *A W ratchet is required (not available from Viking), Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards, S. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromati& Standard Response Upright Sprinkler VKIOO is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Cap - Wrench Flat Standard Sprinkler Standard Sprinkler Wrench for Wax Wrench 21475M1B Coated Sprinklers 10896W/B Figure 1: Standard Sprinkler Wrenches Form No. F052014 19.1014 Rev 19.1 Page 3 of 6 MICROMATIC® STANDARD III[Ui7Mi RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email, techsvcs@viklngcorp.com Visit the Viking wobsite for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color - Ordinary 135 °F (57 C) 100 F (38 C) Orange Ordinary 155°F(68°C) 100 9F(38°C) Red Intermediate 175 F (79 C) 150 (65 C) Yellow Intermediate 200 F (93 C) 150 F (65 °C) Green High 286 °F(141 °C) 225 4F(107°C) Blue Extra High 360 °F (182 C) 300 F (149 C) Mauve Ultra Highs 500 °F (260 °C) 465 ¶ (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135 °F (57 °C). Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 F (141 °C) Dk. Brown Wax5 Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction, Refer to specific installation standards, Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 F (149 C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only, Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 5 Wax melting point is 170 F (76 °C) for 286 F (141 C) temperature rated sprinklers. Form No. F 052014 19.10.14 Rev 19.1 Page 4 of 6 N 1K, J ISI G ® MICROMATIC5 STANDARD RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N industrial Park Drive, Hastings Ml 49058 Telephone: 269445.9501 'Technical Services: 877.384-5464 Fax: 269-818-1680 Email: techsvcsvlklngcorp.com Visit the Viking webslto for the latest edition of this technical data page: www.vIklnggroupinc.com Approval Chart I (UL) Temperature KEY Finish Micrornatic Standard Response Upright Sprinkler VKIOO X4 6Q (iIapØeae) Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals5 Base Part SIN __ (Refer also to UI. Dnlqn Crftrl.) Number' NPT BSP U.S.metrIc2 Inches mm cULus4 F VdS I LPCB (E Standard Orifice 12986 VKIOO 1/2" 15 mm 1 5.6 80.6 2-1/4" 57 Al, 83, C4, 02, 12993 VKIOO 15 mm 5,6 80$ 2-1/4" 67 Al, B3, 04, 02, ES - - NOTICE T Product :a'i limited Avadability 10138 VKIOO 112 15 mm 56 806 2-17167 Al B3 04 D2 ES - - - 10193 VKIOO - 15 mm 5.6 80.6 2-1/4" 1 57 Al, B3, C4, D2, ES - - - Approved Temperature Ratings A- 135°F (57 'C), 155°F (68 °C), 175°F (79 °C), 200 °F (93 "C), 286 °F (141 °C), and 360 "F (182 Approved Finishes °C) I - Brass, Chrome, White Polyester56, and Black Polyester" B 135 'F (57 °C), 155 "F (68 °C), 175°F (79 'C), 2 - Brass and Chrome and 200 °F (93 °C) 3 - Wax-Coated Brass and Wax Over Polyester5 C - 286 °F (141 °C) 4 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient tern- D - 500 °F (260 "C)7 perature allowed at ceiling = 150°F (65 °C) E - 155 °F (68 'C), 175 °F (79 'C), 200 °F (93 5- ENP °C), 286 °F (141 °C), 360 'F (182 'C), and 500 °F (260 'C)7 Footnotes I Base part number Is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Other colors are available or: request with the same Listings and Approvals as the standard colors. 7 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 'F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 "F (149 'C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. DESIGN CRITERIA- UL (Also refer to Approval Chart 1.) cULus Listina Reaulrements: The Viking Micromatic Standard Response Upright Sprinkler VKIOO is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, Installation, and maintenance Information, Viking sprinklers are to be in- stalled In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSADr VCIS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F 052014 19.10.14 Rev 19.1 Page 5 of 6 ----------------- N MICROMATIC® STANDARD I l:IIIuyML RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269445.9501 Technical Services: 877.384-5464 Fax: 269-818.1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY Micromatic® Standard Response Upright Sprinkler VK100 Maximum 175 PSI (12 bar) WWP AIX4 Escuttheon(rrtIe) Sprinkler Base Thread Size Nominal K-Factor Overall Length FM Approvals' Part Number4 SIN (Refer also to Design Criteria below,) NPT I BSP U.S. F metric2 Inches mm Standard Orifice 12986 VK100 1/2" 15 mm 1 5.6 80.6 2-114" 57 Al, 82, C3, Dl, E4, F6 12993 1 VK100 I - 15 mm j 5.6 80,6 2-1/4" 1 57 Al, Dl, E4, F6, G5 lNOTICE Product Below Limited Availabil 7mlLocal Vikingfillz 10138 VK100 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al, 82, C3, Dl, E4, F6 10,193 VK100 - 15 mm 5.6 80.6 2-1/4" 57 Al, G5, Dl, E4, F6 Approved Temperature Ratings A- 135°F (57 "C), 155 IF (68 "C), 175 IF (79 "C), 200 Approved Finishes "F (93 C), 212°F (100 °C), 286°F (141 "C), and 360 °F (182 "C) 1 - Brass Chrome, White Polyester4, and Black Polyester, B - 135 IF (57 "C), 155 IF (68 "C), 175°F (79 "C), 200 IF 2- Wax-Coated Brass (corrosion resistant) :°° "C) 3 - High Temperature 200 IF (93 "C) Wax Coating (corrosion resistant); maximum ambient D - 500°F (260 "C)5 temperature allowed at ceiling = 150 IF (65 "C) E - 155 IF (68 °C) 4 - Wax-Coated Brass and Wax Over Polyester' F - 155 °F (68 "C), 175 IF (79 "C). 200 IF (93 "C), 286 IF 5-White Polyester and Wax-Coated Brass (corrosion resistant) (141 "C), 360°F (182 "C), and 500°F (260 "C)5 G-135°F(57°C), 155°F(68°C), 175"F(79°C),and 6- V EN 200 "F (93 "C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 'Sprirklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 IF (149 "C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 IF (149 "C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2.) FM Aoeroval Reauirements: The Viking, Micromatic Standard Response Upright Sprinkler VK100 is is FM Approved as standard response Non-Storage upright sprinkler as Indicated In the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM LOSS Prevention Data Sheets (including Data Sheet 2-0), FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULue andior NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance Information. Viking sprinklers are to be In- stalled In accordance with the latest edition of Viking technical data, the appropriate standards of NFPAI, LPCB, APSAD,, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052014 19.10.14 Rev 19.1 Page 6 of 6 MICROMATIC® STANDARD I RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945-9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikInggroupinc.com Sprinkler wrench 13577W18** must be used for Installing wax coated sprinklers. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinkiger wrench flats. Wax Coated Or Upright Sprinkler ** A 1/2" ratchet Is required Step 2: Carefully press the wrench downward (not available from Viking) and ensure engagement with the sprinkler wrench flats. Figure 2: Socket Wrench 13577W1B for Wax Coated Sprinklers Form No. F052014 19.10.14 Rev 19.1 Replaces Form No. F052014 Rev 17.1,P65 (Added ENT updated FM language.) IiEi SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. ID. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE I 1.315 1.097 15.27 141 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.16 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2,875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft :. 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS - - - -. ----- - ---- - NOMINAL PIPE an, ID. WATER FILLED BUNDLE SIZE (IN) (IN) - (IN) CRR 4 WEIGIITIFT WEIGHT SIZE 1 1,315 1,049 1.00 1,68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft - 2.918 51 1-1/2 1.900 1.610 1,00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 41500 4.026 1.00 10.80 lbs/ft 16.316 19 CasA &dcAZ R&t*c Ratio pt Iatst L& Ortøy Lstfiy PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. C For Additional Information Contact (800) 325-4467 www.bultrnoosetuhe.com Or From Canada Call (800) 882=4666 saIesbulIrnoosetube corn - - 1819darksanr(od hstfJd. MO Ge1& MO Kentft ca GndA2 0211KU Mast OH 63017 BuU Moose Tube's° Schedule IG and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube° made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other tine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tubes0 Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specification& EU LIP E REPLA&EMENT P PE Dull Mooselube's° Eddythread4Q° ADVANTAGES OF BULL MOOSE TUBE° EODVTHREAD 400 U is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0, Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type F, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM'S requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. EDDVTHREAD 400 SPECIFICATIONS NOMINAL PIPE OL D. ID, WEIGHT WATER FILLED HUNDLE SIZE (IN) (IN) (IN) CRR* L8/FT WEIGHT SIZE - -------- .. I 1.295 1,083 1.00 1.461 1.860 10 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.541 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 kftrst - katia W utt ut Weamy Lk* PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt chip grease, and rust must be removed prior to installation. Failure to take these important steps may result in Improper coupling assembl causing leakage. Also, check the manufacturer's lnstrudions for the specific fitting used, ( 0 For Additional information Contact (800) 3254467 www.buIlrnoosetube.com Or From Canada Call (800) 882-4666 salesbulImoosetube corn 1G19CLksoiRod theteitekLM0 GeckI, MO KcntWA CasaGmt14AZ DUa,tX Masu ON Bul[ Moose Tube's° Eddylite° is a lightwall threadable pipe manufactured in NPS 1 through 2k". Eddylit& is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite° is manufactured to meet the requirements of ASTM Al 35 and A195 specifications. This pipe product has been fully approved by Factory Mutual and listed by Underwriters Laboratories (for U.S. and Canada) for use in tire protection systems with a working pressure of 300 psi or less. r c®us LISTED <9> OAMA NFk ADVANTAGES OF BULL MOOSE TUBE° EDDVLITE° Standard outside diameter, unlike some other lightwall threadable pipe products. tighter in weight than Schedule 40 Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASIM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves, Freight savings Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30: compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) 0.0 (IN) DIAMETER (IN) THREADED UNTHREADED PER FT FILLED SIZE - 1 1.315 1.137 0,13 1.47 1,260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1,967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 Rst .tki pt Ltt UL Diredwy iiuirtq PIPE PREPARATION For proper operation, all pipe surfaces should he cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dlrt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A A For Additional Information Contact (800) 3254467 www.bullrnoosetube.com Or From Canada Call (800) 8824666 salesbullmoosetube corn U 18i9 CLAW [toad Cttethk MO GeralcL MO Kenl4WA CaGrndA2 091X masuri ON FAA -ftv 10017 c®us LISTED * I;] HFPK s ADVANTAGES OF BULL MOOSE TUBE° EDDY FLOW° Certified to ASIM Al 35 and A795 Type E. Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for US. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet dry, preaction, and deluge type sprinkler systems. lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi, Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD 110 MIC preventative coating. NPS O.D. EDDY FLOW EDDY FLOWO WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. Wt, SIZE 1-114 11660 1,530 1.98 1-112 1.900 1.728 3.44 2 2.375 1203 2.78 2-1/2 2.875 2.705 1.66 3 3.500 3.334 1.00 4 4.500 4.310 1.00 *Corrosion Reasisitartte Ratio W tattst UL Dfmctory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly; causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 3254467 www.bullmoosetube.com Or From Canada Call (800) 882-4666 sales@thullmoosetube corn 1819ckvkn Road Chswft MO GerA MO KntWA Cam Giiande, AZ Dallaox mmtq OH 63017 KA Buti Moose Tue's0 Eddy Flow0 is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design fIexibility. This product is FM approved, as well as UL listed (for U.S.and Canada) for roll grooving and welding. As an added benefit,, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's0 larger ID provides an opportunity for downsizing and further cost savings. 1.222 21019 61 1.844 2.860 61 2.330 3.982 3 2.809 5.299 30 3.361 7.144 19 4.968 11.290 19 u Moose Tube Ultra Eddy* Is B ll ADVANTAGES OF BULL MOOSE TUBE° ULTRA EDDY a versatile product that can be a Certified to ASTM Al 35 and A795 Type E, Grade A. rolt grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products.. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet dr preaction, and deluge type sprinkler systems. Lightweight saves shipping costs, offers easier handling. Muttidimensionak Can be used with all Schedule S approved roll grooved, welding and Presstit Products for pressures up to 1 IS psi Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy* offers substantial Improvements In hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS ULTRA ULTRA EDDY WEIGHT WATER BUNDLE (IN) (IN) EDDY (ID) CRR** PER Ft FILLED WE SIZE - -------- . rt. - I 1.315 1.201 2.17 .868 1.35 91 11/4 1.660 1.546 1,40 1.107 1.920 61 1-112 1.900 1.786 1.11 1.274 2.360 61 2 2375 2.261 1.00 1.604 3.344 37 hkfd tna&mark ofWth!fk Company fAmerica R MOO p4wiatt WrMbiy PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembk causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 www builmoosetuhe corn Or From Canada Call (800) 882.4666 saIesbutIrnoosetube torn 83 1819 Cthrltsøn Kod t1cLM0 6ak,M0 Keni4WA UttaTX M0H 6Q17 B MPS (IN) 1 11I4 11/2 2 21!2 3 4 am (n) 1.315 1.660 1.900 2.375 LD4n) 1.201 1.546 1.786 2.261 ULTRA EDDY EmptyWeitØbtft) 0.868 1.107 1.274 1.604 Vrater-Filled 11.159 1.920 2.360 3344 C.R.R. 2.17 1.40 1.11 1.00 1.660 1.900 2.375 2.875 3.500 4.500 1D.n 1.530 1.728 2.203 2.705 3.334 4.310 EnWtOMt 1.222 1.844 2.330 2.809 3.361 4.968 EDDY FLOWS Water-Filled Weqn 2.019 2.860 3.982 5,299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 OLD. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4,500 I.D.n 1.097 1,442 1.682 24157 2.635 3.260 4.260 SCHEDULE EmptytOMt1 1,410 1.810 2.090 2.640 3.530 4.340 5,620 10 Water-filled gtflOhtft 1.820 2.518 1053 4.223 5.893 7.957 11.796 c.R.R. 15.27 9.91 7.76 6.27 4.92 354 230 1.315 1.660 1.900 2.375 LD4in) 1.137 1.482 1.712 2.177 EDDYLITE I EmptyWeight(bMt 1.260 1.617 1.967 2.617 Water-Filled We,tQMi) 1.700 2.364 2.965 4.230 0.13 0.08 0.12 0.16 0.0. 1.295 1.650 1.900 2.375 ID.(n) 1,083 1,418 14645 2.123 EDDYTHREAD 40v Empty Wekjht (IMt) 1.461 2-070 2.547 3.308 0t'-F3IkdWenOMt), 1.860 2.754 3.468 4.842 CR.R. 1.00 1.00 1.00 1.00 am 1.315 1160 1.900 2.375 2.875 3,500 4.500 LD.jn) 1.049 1.380 1.610 2.067 2.469 ' 3.068 4.026 SC ED HULE 1 EmptyWejt(1&1t) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 tei-FiUedWeghtthtft 2.055 2.918 3.602 5.114 7.875 10.783 16.316 L. C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 For Additional Information Contact (800) 3254467 C11 WWW.bullm005etube.COm D Or From Canada Call: (800) 8824666 sales@butlmo08etube.com 1819CInHoad thtethkt MO Gk. MO Kent WA Cam GiandA2 0" TX Miit ON 63011 19 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY 0.868 91 1,659 1,896 1,975 SCHEDULE 10 1,410 91 2,695 3,079 3,208 MYLITE0 1,260 91 2.408 2.752 2.867 EDDYTHREAD 40' 1.461 70 2.148 2.454 2.557 SCHEDULE 40 1.680 70 2.470 2,822 2.940 ULTRA EDDY* 1.107 61 1,418 1,621 1.688 EDDY FLOW* 1.222 61 1,565 1.789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2.760 1-114 EDDYLJIE° 1.617 61 2,071 2,367 2,466 EDDYThREAD4O° 2.070 51 2,217 2,534 2,639 SCHEDULE 40 2.270 51 2,431 2.778 2,894 ULTRA EDDYV 1174 61 1,632 1.865 1,943 EDDY FLOW 1,844 61 2.362 2,700 2.812 SCHEDULE 10 2.090 61 2,677 3,060 3,187 1112 EDDYIIIP 1,967 61 2,520 2,880 3,000 EDDYIHREAD 40' 2.547 44 2.353 2,690 2,802 SCHEDULE 40 2.720 44 4513 2,872 4992 ULTRA EDDY* 1.604 37 1,246 1,424 1,484 EDDY FLOW 2.330 37 1,810 2,069 . 2,155 SCHEDULE 10 2.640 37 2,051 2.344 2,442 2 EDDYLITE° 2.617 37 2,033 2,324 2,421 EDDYThREAD 40 3,308 30 . 2,084 . 2,382 2,481 SCHEDULE 40 3.660 . 30 2,306 2,635 2.745 EDDY FLOW3 2.809 1,770 2,022 2,107 2-112 SCHEDULE 10 3.530 30 2.224 2,542 2,648 SCHEDULE40 5.800 3,654 4,176 4,350 EDDY FLOW' 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4.340 19 . 1,732 1,979 2.062 SCHEDULE 40 7.580 3,024 3.456 3,601 EDDY FLOW' 4.968 1,982 2,265 2,360 SCHEDULE 10 . 5.620 19 2,242 2,563 2,670 SCHEDULE 40 . 10.800 4,309 4,925 5,130 6 SCHEDULE 10 9.289 10 1,951 2,229 2,322 SCHEDULE 10 16.940 7 2,490 2,846 2,965 OAv1be in Casa CtawkAL I c®us LISTED I] 4\os4 NEPA' ID II1EE 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullrnoosetube.com saies@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or CompressionlGrooved Couplings Max Zone of Influence Load (iw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7.05 ) & Cp for NFPA13 shown in BOLD TYPE 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 Pipe Size Transverse Brace Spacing1 20ff, 25 ft. 30 35 ft. 40 ft. 1114 136 109 89 75 6440 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 1/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 631 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 126 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or CornprcsslonlGrooved Couplings Max Zone of Influence Load (1) lbs Max Transverse and 4-way Brace Spacing (ft.) According to Pipe Transverse Brace Spacing* HLF for the 2006 & 2009 IBC (ASCEO ) & Cp for NFPA-13 shown in BOLD TYPE Size 20 ft 25 ft 30 ft 35 ft 40 ft 025 0.60 1. 50 115 200 225 250 275 300 1 119 95 78 67 56 40 40 36 25 24 22 21 20 19 18 1114 218 175 143 123 103 40 40 40 075 T3733 28 26 25 23 22 21 20 1 112 312 250 205 115 147 40 40 40 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 33 30 29 27 26 24 23 ( For Additional Information Contact (800) 32S-4467 www.buiimoosetube.com Or From Canada Call (800) 882.4666 saIesbullmoosetube corn - 181gclak,nROW chestefielit GeitkLM0 KetiIWA Casa DU1X MWA" ON 63017 11 VechanicaI-T STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED JOBICWNER CONTRACTOR ENGINEER System No. Submitted By, Spec Sect Para__________ Location Date Approved www.ictauflc.cam vicTAuLic IS A REGISTERED TRADEMARK OF VJCTAULJC COMPANY, 02017 McTAuUC COMPANY. ALL RIGHTS RESERVED. Date /ctauiic Victaulic Mechanical-I® Outlet provides a direct branch connection at any location a hole can be cut in pipe, The hole is cut oversize to receive a °holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe 0,0. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections, NOTE; Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/$45OkPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or paly- butylene (HDPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe, Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920M must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap ii Mechanical-I unit. See page 8 for further information, MATERIAL SPECIFICATIONS Housing/Coating Ductile iron conforming to ASTM A-536, grade 65-45-12, With orange enamel coating, Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional Hot dipped galvanized Gasket: (Specify choice*) Grade "E' EPDM EPDM (Green color code), Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified: in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot 4-180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T' nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. BoitslNuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. iL21 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use. with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N. houstngs cannot he mated to one another to achieve cross connections, ' 1') 0 4 C Fly a -s 4 aT"s :m 5ss 18 5k i4 AM aar 42P1, 1' 2 x 4(a) n 1 9204 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 15 3450 38.1 - 51 64 4' 136 - 70 1.5 - 920N 500 1,50 1.97 2.53 1.61 535 2.75 3 20 3450 33,1 50 54 41 36 70 1 5 - 1 9204 500 - 1.50 - 1.35 2.53 - - 1.61 - 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 70 1 .4 - 1,14 (a) to920N 530 1,75 2.05 2.75 3.00 1.61 535 300 35 3.2 32 3450 44.5 -. 52 70 76 41 136 - 76 17 1,5 1½)/4l-a 9204 500 1.75 2.03 ' 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 21/2 ½ (8) §004 00 1.50 2.21 2.74 - 1,82 64 2.75 30 65 15 3450 38.1 56 70 46 143 70 1.4 - 500 1,502.18 2.74 1.82 5,642.75 3.0 20 3453 38.1 - - 55 70 - 45 143 70 1.4 - 920N 500 1,50 2.06 2.74 1.82 5.64 2.75 ' 2.9 - 25 3450 38.1 52 70 46 143 70 1,4 1/43(a)o 2 1 500 75 230 300 325 182 29 00 35 - 32 32 3450 445 58 76 83 46 160 76 1.7 1.5 1½ 3(a) a90N 500 2.00 2.28 3.00 3,25 1.82 6,26 325 3.6 3.3 40 3450 50.8 58 76 83 46 59 83 - 1.7 1.6 .1 ½ fa) x 90N 300 1.50 2.22 2.75 2.25 6.46 3,18 3.9 15 2065 331 55 70 57 164 31 1.8 - 4(a) 9204 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 , 56 70 - 57 164 81 1,3 - I (a) 9204 300 1.50 2.07 2.75 2.25 6,46 3.18 3.8 - 25 2055 38.1 53 70 57 164 81 1.7 9204 500 l 2.30 3.00 3,31 1/42 6,29 3.00 3.5 3,2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1½ (a) n 9204 500 2.00 2.28 3.00 3,31 1.92 6.29 3.25 3,5 3.3 40 3450 50.8 58 75 84 49 160 83 1.6 1,5 3 4(a) 2 9204 500 1.50 2.52 3.05 2.28 6,15 2.75 3.4 80 15 3450 38,1 64 78 - 58 155 70 1.6 - 3/4 9204 500 1.50 2.49 3,05 2,28 6.15 2.75 3,4 20 3450 33,1 53 78 - 58 156 70 1,6 - 1(a) 9204 500 1,50 238 3.06 2,28 6,15 2,75 3.3 25 3450 38.1 51 78 - 58 156 - 7-0 1.6 - 1 4(a) to 920)9 500 1.75 2,55 3.25 356 2.28 5.15 3.00 3.8 3,7 32 (h) 3450 44,5 65 83 90 58 155 76 1.8 1,8 11/2 (a) ha 9204 500 - 2.00 2.78 3.50 356 2.28 5.15 3.25 4,1 3,8 40(b) 3450 50,8 71 89 90 58 156 83 1.9 1.8 2(a) c 9204 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.5 50 3450 53.5 70 89 90 58 172 99 23 2.1 31/2 2 5002'50 3.00 3.75 2.44 5.72 3,88T 3.8 90 59 920N 3453 635 75 - 95 62 171 99 - .8 TABLE CONTINUED ON P. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order, * Center of run to end of fitting, It Female threaded outlets are available to NPT and BSPT specifications, @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet Is available as listed. Specify "BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 21/2 B5PT clearly on order, § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.vlctauUc.com '/ctauIiC' VIcTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIc COMPANY. ALL RIGHTS RESERVED. 11.022 PEVJJ CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FIT. 4) im %51i ' '12 i 0 13 'aa sr .71x'8 ' _I _b 1I &VA 414 6----Wi TABLE COPTlNUED FROM PAGE 2 4 ½ lar 500 .50 3 03 3.55 2.59 7,01 2.75 3.7 100 x 11 9201\l 3450 38.1 77 90 - 68 178 70 .8 9ON 500 1.50 3.00 3,55 - 2.59 7.01 2.75 3,7 - 20 3450 38.1 76 90 68 178 70 1.8 1(aa 0 50 288 - 3.56 - 269 701 275 36 - 25 90N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET I (a) ta 920N 500 1,75 3.08 3.78 4,00 2.69 7.01 3.00 4.0 3.6 32 (b) 3450 44.5 78 96 102 .58 178 76 1.9 1.8 1 '/2 (a) 'ia 500 2.00 3.28 4.00 4.00 2,69 7.01 3.25 4.2 3.9 F ________40(b) 920 3450 50.8 83 102 102 58 178 83 20 1,9 V I . . . " - . . 2(a) Va 500 2.50 3.25 4.00 4.00 2,69 7.01 3.88 5.0 4.6 920N 3450 635 83 102 102 68 178 99 2,3 2.1 V f: 1 2½(a)t 920 500 2.7S 2.88 400 4,002.59 7.34 4.63 5850 ' T , 65 3450 , 69,9 73 102 102 69 186 118 , 2.5 2.3 71 92 5002.75 2.88 4.002,597.34 4,63 6.4 5. mm 0 3450 69.9 73 - 102 68 186 , 118 ' 2.9 3(ar V 500 3.50 331 4.50 4.12 2.69 7.73 5.12 8.4 64 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET . . . - - ,. 90 (a 920N 500 .75 3.08 3,7e - 2.63 7.64 3.05 5.0 32 3450 44.5 78 96 67 194 78 2.3 1 ½ a)a T 500 2,00 3,28 4.00 2,63 7,64 3.25 5,0 Provides a direct branch connection at 40 920N 3450 50.8 83 102 67 194 83 2.3 - any location where a hole can, be cut 2a1 9205: 500 2.50 325 4.00 - 2.53 7.64 4.00 4.0 - in the pipe 50 ), ' 345063.5 83 102 - 67 194 102 1.9 - 761 920 500 2.75 2.88 4.00 4,00 2.63 7.64 4.29 8.0 7,8 A pressure responsive gasket provides , mm 3450 69.9 73 102 102 67 194 109 3,5 3.5 the seal 3(a) 920 500 3.50 3,31 4,50 4.50 2,63 7.63 4.88 6,8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 Request Publication 11,03 for s 15(a) t 920 aOo 200 - 403 - 475 - 475 316 * 970 69 74 - 76 Mechanical-I cross assemblies 125 "'< 40 -- 345050,8 102 121 121 80 24594 34 3.4 2 920 500 2.50 4.00 4,75 4.75 3,16 9.70 4.38 8.2 8.0 Pressure rated up to 500 psi13450'kPa 53 - 3450 53.5 102 121 121 80 246 111 3.7 35 on steel pipe also available for use 2½ (a) 4 920 500 275 3.63 4,75 4.75 3.16 9.70 4.53 8.3 7.9 with: HDPE pipe 65 , 3450 - J1L_..° 246 118 , 3.8 3.6 6 1 ' 500 2.75 3.75 4,75 3.16 9.70 4.63 8.0 Sizes from 2x ½/50 1' mm 920 15mm 3450 699 95 1280 246 118 - 36 through: 8 x 4/200 x 100mm 3(a) t 920 500 3,50 381 5.00 4.63 316 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 32 4.0 2 500 2.50 3.75 4,50 3.17 8.00 3.88 8.0 133,0 x 50 92014 3450 63.5 95 114 81 203 99 3.6 - 3 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 920 3450 88,9 97 127 - 76 240 135 3,6 - IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate. Style 920 and Style 9201NJ housings cannot be t Available with grooved or female threaded outlet. Specify choice on order, mated to one another * Center of run to end of fitting. to achieve cross connections, if Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for FIre Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order, (h)For 76,1 mm threaded outlet, specify ½" BSPT clearly on order, § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company, wwwvctauric.com vicTAuLic IS A REGISTERED TRADEMARK OF ViCTAuLIC COMPANY. e. 2017 vicTAuLiC COMPANY. ALL RIGHTS RESERVED, ictaLi iC' REV" 1102_3 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS re C d3 'n . 4 Y l4-Z-- * TARI,E CONTINUED FROM PAGE Soo 1397 40 920N 3450 508 96 - 84 209 83 3.2 - 2t20N 500 2503.75450 330 8.23 3.88 9D so 3450 63.5 95 114 84 209 99 4.1 W 6 1 1/4 (a) 920N 500 1.75 443 5,13 5.13 3.79 9,15 3.25 51 4.8 -- --f' 50_I 3450 63.5 95 114 84 209 99 4.1 - W S 1¼() 500 1,754,435.135.133.799,15 3.25 5,1 4.8 150 ' 32(b) 9208 3450 44,5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1/2(a) ta 920N 500 200 440 513 513 3.79 915 325 54 51 40 Ib, 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)ta 500 20 438 5.13 51 79 915 388 60 6 Y 50 9201 3450 63.5 111 130 130 96 232 99 2.7 2.5 4 b . - - ________ 2 ,5 20 500 2.75 4.01 5.13 5.12 3.69 10,51 4.63 8.3 7.6 65 3450 59.9 110 130 130 94 267 118 3.8 3.4 V 761 2 500 275 41 21 369 IQ ,,9 463 84 ' T . . n' 9 0 3450 69.9 105 - 132 94 267 118 3.8 4 92 500 3,504.31 5.50 5.13 169 0.51 5.31 9.9 8.4 W 80 0 3450 88.9 110 140 130 94 267 135 4.5 3,8 4(a) 35 500 4.50 3.81 5.75 5,38 3,69 10.51 5,25 10.1 10,1 FEMALE THREADED OUTLET . . 100 920 3450 114.3 - 97 146 137 94 267 159 4.6 4.6 -. 190 X 1 3(a) 9204 500 2.00 4.41 5.13 3,63 9,40 3.25 7.8 40 3450 50.8 112 130 92 239 83 3.5 - 2 (a) 500 2,50 4,38 513 3.63 9,40 3.88 8.0 Provides a direct branch connection at so 9238 3450 63.5 lU 130 - 92 239 99 -_ 3.6 any location where a hole can be cut 761m 920 500 275 4 -- 50 5 3 363 94Q 463 95 95 in the pipe ''m 38 3450 69.9 111 140130 , 92 239 118 4.3 4.3- 3 .. 560 3.50 4.31 5.50 5.13 3.63 9,40 5.31 87 14,0 A pressure responsive gasket provides 80 3450 88,9 110 , 140 130 92 239 353] 6.4 the seal 1080mm g0 530 4.50 4,45 - 5.38 3,63 9,40 6.12 - 10,0 3450 1143 113 137 92 239 155 4.5 Request Publication 1103 for ' 500 4.50 3.81 5.75 - 3,63 9.40 6,25 180 - Mechanical-T cross assemblies 100 3450 1143 96.80 146 92 239 159 8.2 TABLE CONTINUED ON P. S Pressure rated up to 500 psi/3450kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), on steel pipe, also available for use t Available with grooved or female threaded outlet. Specify choice on order. with H DPE pipe * Center of run to end of fitting. Sizes from 2 x 1/2750 x 15mm # Female threaded outlets are available to NPT and. BSPT specifications, through 8. x 4/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings.. (a) British Standard female pipe threaded outlet is available as listed, Specify "BSPT' clearly on order, (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services 0 LPCB approved for fire protection services IMPORTANT NOTES 0 Approved for use in China by Tianjin Approvals Company, Style 920 and Style' 920N housings cannot be mated to one another to achieve cross connections, www.vtctauflccom VICTAULIC IS A REGISTERED TRADEMARK OF vlcTAuuc COMPANY. D 5017 viCTAUUC COMPANY. ALL RIGHTS RESERVED. 04-C.-t-suba 1LO24 REH CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-Ta Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS (1 0 , ) Y 20' 'W TA O 99 116 96 237 70 3.6 TABLE CQP3TINVED FROM PAGE 4 105 >' 920N 32°Q 388 456 - 379 9i4 275 80 - 75 4.43 5.13 - 3450 445 13 - 96 237 83 3.8 1/2 'a) ' 00 200 441 5.13 53 379 934 3a5 84 54 40 5O 508 112 130 130 96 27 83 3.8 24 GROOVED OUTLET 2 (a)t 920N 500 2.50 - 4.38 5.13 -, 5.13 - 3.79 9.34 3.88 -- 8.5 6,0 50 3450 63,5 111 130 130 - 96 237 99 3.9 2.7 500 2.75 4.01 5.13 5.21 3,63 10.51 4.63 8,6 7.6 76.1 mm 920 3450 69.9 110 130 132 92 267 118 39 3,4 4 YZ - - 3 (a) So 500 3.50 431 5.50 5.13 3.63 10,51 5.31 10,2 8.4 80 920 3450 88.9 110 140 130 92 267 135 4,6 3.8 v 4'a) 920 590 450 381 575 538 363 10 625 105 84 '.' 100 3450 - 143 97 145 137 92 267 159 4.8 3.8 - 8 x 21a1t 500 2. 755 542 619 625 481 1242 450 11.6 11.6 92 'N 200 50 0 3450 69.9 138 157 159 122 316 114 5.3 5,3 2/1(a)f 500 215 - 507 6.19 619 - 4.81 1242 450 116 116 11 920 3450 69.9 129 157 157 122 315 114 5.3 5,3 FEMALE THREADED OUTLET - •. - .. .. 751 mm 920 .0u z,75 6.25 4.8 12.42 4.56 11.6 - 3450 69,9 133 - 159 122 316 116 53 3:1;,t 500 0 531 650 650 481 1242 53 26 116 Provides a direct branch connection at 920 3450 , 88.9 135 - 165 165 122 316 135 5.7 5.3 any location where a hole can be cut , 4(a)t 920 500 450 4,811 6.75 6,38 4,81 12.42 6.25 15.3 12.5 in the pipe 100 3450 143 122 171 162 22 316 159 5,9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), A pressure responsive gasket provides t Available with grooved or female threaded outlet. Specify choice on order. the seal * Center of run to end of fitting, Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: Pressure rated up to 500 psi/3450kPa (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. on steel pipe also available for use (b)For 76.1 mm threaded outlet, specify 21/2" 8SPT clearly on order. with. HDPE pipe § Vds approved for fire protection services o LPCB approved for fire protection services Sizes from 2 x ½/SO x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through. 8 x 4/200 x 100mm IMPORTANT NOTES: Style 920 and Styie 920N housings cannot be mated to each other to achieve cross connections. www.vktaullc.com VIGTA'JLIC IS A REGISTERED TRADEMARK OF VICTAIJLiC COMPANY. C 7017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02.5 CARBON STEEL PIPE HOLE CIII PRODUCTS 11.02 Mechanical-T' Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T5 fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C and KvValues Values for flow of water at +60VFIi 160C are shown in the table below. Formulas for CY,K, VaIuei AP =Q2 Where: AP = Q2 Where: ' c2 Q = Flow (GPM) Q = Flow (m3/hr) ( \ Q = C x IIEP AP = Pressure Drop (psi) C = Flow Coefficient v AP = Pressure Drop (Bar) Q = K x lK = Flow Coefficient Exaggerated for clarity TJrL 14 ½ 0,840 - 2 - 11 5 .9.4 ½ 1.050 ' 16 20 26.7 - - - 13,7 1 1,315 - 21 25 - 33.7 - - - . - 1.8 - 1 /4 1.660 5/ 6 50 48 32 42,7 1 - - -- - 42.9 41,1 1 ½ 1.900 . . . - . 40 98.3 ,j 45.4 454 2 2,375 f -- —I 112 104 60 50 .3 ' 10 V - 96 - 89.1 2112 2.875 - 't ----------'~ - '- ti ' 150 65 73.0 - - - . 102 1285 3,000 76.1 mm V 16 161 76.1 138.1 - - - 3 3.500 1 14 15½ 249 237 30 38.9 - 213.4 - 203.1 4,500 20 - 22 421 401 100 1 114,3 j 608 343,6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14,2mm. 1' FireLock' Innovative Groove System (IGS) outlet wwwvtctaullc.com jtauIic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11,02.6 RV/J$ CARBON STEEL PIPE. HOLE CUT PRODUCTS 11.02 Mechanical-Ta Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication, Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victautic for performance on other pipe and the latest listings and approvals. r10 21/2 - 6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0- 166,3 2755 - 2755 2755 1999 - 1599 2496 21/2-4 2.875-4.500 All OF 300 300 300 290 - 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4,500 All - 300 - 300 300 290 - 232 - 362 65-100 73,0-114,3 2065 2065 2065 1990 - 1599 2496 6 6,625 34 10 300 300 -- - 250 290 232 - 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 •' 34 30,40 300 " 300 300 290 232 362 150 68.3 , 2065 2065 2065 1999 1599 - 2496 8 8.625 21/2 - 10,40 400 - - , 145 - 200 219,1 ' 2755 - 1000 8 8.625 10 300 - 250 ' - - 145 200 219.1 - , 2065 , 1724 , - 000 - 8 8.625 040 300 - 300 - - 145 200 219.1 ' 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 87100 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The. Vic-Tap It is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II' Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm, 6.7150mm and 87200 mm diameter pipe. The Style 931 comes with a 2½765mm grooved, outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to. publication 24.01. wwwvldauIccom Aa2isuhd vIcTAuLIC IS A REGISTERED TRADEMARK OF vtciuuc COMPANY. 2017 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV-" 1102,7 MechanicalV0 STYLES 920 AND 920N INSTALLATION Reference should always be made to the lIOQ Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victauliccom. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details, NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions, Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit wwwvictauliccom 51.02 1480 REV UPDATED 1212017 ictauIi VICTAuLIC IS A REGISTERED TRADEMARK OF VICTAuuc COMPANY. o 2017 VICrAuuc COMPANY. ALL RIGHTS RESERVED. 1L02L STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'A through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No, Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com VITAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REt1G \ 4taulic 10,521 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outleti' STYLE 922 DIMENSIONS /2 13/16 1.30 183 279 983 650 045 I / &Wj \\ /1 3/4 1 /I6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 1.52 2.18 1.10 - 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 x ½ 13/16 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 13/16 1.40 1.95 W 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A6 1.64 2.30 1.22 - 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 x 1/2 13A6 1.66 2.19 1.46 4.60 - 2.56 1.3 50 15 30.2 42.2 55.6 37,1 116.8 65.0 0.59 3/4 13A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1/6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 x ½ 1 3/16 1.91 2:44 1.71 ' 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 Y4 1 1.89 2.44 1.71 5.40 2.56 1,6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3A6 2.13 2.79 1.71 5.40 2.56 1.6 25 . - 30.2 54.1 70.9 43.4 1372 65.0 0.73 ½ 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1 1/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com \JtauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52..2 REVG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock! OutleW STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com ,. VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. aulic REVG 10,523 FireLock STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 1212009 ictaulic vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY, ALL RIGHTS RESERVED. 1052 Ductile Iron Threaded Fittings O MITH..,COOPEJI~ Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP Ductile iron castings conform to ASTM A536 cULus LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent tab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 c®us ? Fig. 35! 3_900 Elbow LISTED Size in Part Number i in Packing Weight lb Inner Master 1/2 3/4 35E3004 35E 3006 35E 3010 113 100 200 0.2 131 70 40 140 0.3 1 1.50 80 0.5 1-1/4 1-1/2 35E 3012 35E 3014 1.75 1.94 25 50 36 18 1.1 2 2-1/2 35E3020 35E 3024 2,26 10 20 1.8 2.70 4 8 3.2 Fig. 35RE3 - 90° Reducing Elbow Size in Part Number A in B in - Packing Weight lb Inner I Master 3/4 x 1/2 36R3006004 1,20 1.22 60 70 - 50 160 03 Th 1/2 35RE3010004 -. 35RE3010006 1.26 1,38 1.36 1.45 140 100 0.4 0.4 1x3/4 1-1/4 x 1/2 35RE3012004 35RF3012006 1.34 1.45 1,53 35 70 70 0.5 0.6 1-1/4 x 1.63 35 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 35RE3014006 35RE3014010 35RE3014012 1.52 1,75 .0 60 0.6 1-1/2 x3/4 1-1/2x't 1.52 1.75 -25 50 01 1.65 1.82 1.80 1.8818 20 40 36 0.8 1.0 1-1/2x1-1/4 2x1/2 35R63020004 1.60 1.97 18 36 1,0 x3/4 35RE3020006 1 1.97 18 16 36 1.0 - 1.2 2 x 1 35RE3020010 1.73 2.02 32 2x1-114 35RE3020012 1.90 2.02 2.10 2.16 12 10 24 20 1.3 - 1.5 2 x 1-1/2 35RE3020014 2-1/2x 1-1/2 024014 2,16 2.1 6 12 2.2 2-1/2x2 1 35RE3024020 2.39 1 2,60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 •' 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 0.7 1-1/2 35F_3014 1,44 20 1 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size In Part Number A in Packing Weight lb inner I Master 1/2 3513004 1,13 80 160 0,3 3/4 3513006 1.31 30 -60 05 35T3010 1,50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 14/2 3513014 1.94 10 20 1.5 2 3513020 2.25 6 12 24 2-1/2 3513024 2,70 4 8 4.3 UI SMITH-COOPER JTERNAT1ONAL® 9 TOLL FREE 1-800766-076 9 FAX (3Th) 90-4456 • www.srnithcooperom Size i . Part Number 'A in B in C in Packing Weight lb Inner Master 3/4 x 1/2 35R13006004 35R73010004 35RT3010004010 120 1.20 1.22 60 30 30 120 60 0.4 0.6 0.6 lx 1/2 1_xl/2x 1 1x3/4 1x3/4x3/4 1x3/4x1 1-1/4 x 1/2 1.26 1.26 1.36 1.50 1.50 1.36 60 35RT3010006 35RT3010006006 1.38 1.38 1.38 1,45 25 50 70 0.6 0.6 1.31 1.45 35 35RT3010006010 1.50 1.45 1.50 50 -07- 0.8 - 35R13012004 ' 1.34 1.34 1.53 20 40 1-1/4x1/2x1-1/4 1-1/43/4 35RT3012004012 35RT3012006 1.75 1.53 i1 1.62 25 15 50 30 0.9 0.9 1.45 1.45 1-1/4x3/4x 1-1/4 1-1/4x1 35R13012006012 35R13012010 1.75 1.62 1.75 1.67 20 15 40 1.0 1.58 1.58 30 1.0 - 1-1/4x1x1/2 35RT3012010004 35RT3012010006 1.34 1.26 1.53 25 50 07 0.8 1-1/4x1x3/4 1,45 1.38 1.63 20 40 1-1/4x lxi 1-1/4xlx1-1/4 35RT3012010010 1.58 1.50 1.69 1,69 1.75 ' 20 40 0.9 1.0 35RT3012010012 1.75 15 30 i-1/2x1/2 1-1/2x1/2x1-1/4 35RT3014004 1.41 1.41 1.66 16 32 48 1.0 1.1 35AT3014004012 1.81 1.56 1.88 24 1-1/2x1/2x1-1/235RT3014004014 1.94 1.66 1.94 16 1224 32 12 1-1/2x 3/4 35R13014006 1.52 1.52 1.75 1.1 1-1/2x3/4x 1-1/4 l-1/2x3/4x1-1/2 35FRT3014006012 1.94 1.66 1.88 20 40 1.1 35RT3014006014 1.94 1,75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 24 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 1-17x1x3/4 35RT3014010006 1.50 1.44 1,75 16 32 0.9 1-1/2xlxl 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 35RT3014010014 1.82 1.67 188 12 24 1.2 1.3-- 1-1/2x1x1-1/2 1.94 1,80 1,94 12 24 1-1/2 x 1-1/4 35R73014012 1.82 1.82 1.88 12 24 1.4 1-112x1-1/4x1/2 35R13014012004 1.41 1,34 1.66 16 32 0.9 1-1/2x1-1/4x314 35RT3014012006 1.52 - AS 1,75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-112 x 1-1/4 x 1-1/4 35RT30142012 1 82 - 75 1 88 14 28 1.3 1.-1/2x1-1/4x1-1/2 353014012014 1,94 1,88 1,94 14 28 1.4 2x 1/2 2x3/4 35RT3020004 1.49 1.49 1.88 10 20 1.5 35R13020006 1.60 1.60 1.97 10 20 1.6 2x1 ' 35RT3020010 1,73 1.73 702 8 16 1.7 2x1x2 35RT3020010020 2.25 2.02 2.25 S 16 1.9 2x1-l/4 35RT3020012 1.90 210 8 ' 16 1.9 2x1-1/4 x2 35RT3020012020 , 2,25 2,10 2.25 8 16 2.0 2x1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT302000 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 ,1.90 1.82 1 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 ' 2,02 1,94 2.16 6 16 1.8 C C®us APPROM Fig. 35RT3 - Reducing Tee USTED Fig. 352T3 - Hull Head Tee Size in Part Number ' in B in C in Packina Weight lb Inner Master 3/4x1 35B13006010 1.45 ' 1.45 4 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 - 1.67 1.67 1.58 20 40 0.9 1 x 11/2 355T3010014 'i.80i .80 11 1.65 15 30 1,0 1-1/4x1x1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 i-1/4x1-1/2 359T3012014 1.88 1.68 1.82 15 30 1.3 1-1/4 x 2 35B13012020 2,10 210 t90 10 20 1,6 i-1/2x 1-1/4 x 2 35913014012020 2.16. 1, 2.10 2.02 10 20 . 1.8 1-1/2x2 ' 35BT3014020 ' 2.16 2.16 ' 2.02 8 1 16 1.8 SMiTH-COOPER INTERNATJC)NAL® • TOLL FREE 1-809-7664)076 9 FAX(323)S90-4456 • svhcprccni 112 Fig. 3303 - Straight Coupling with Ribs c®us <> APPMWED LISTED Size Part Number A in Packing Weight lb Inner Master ____ 1/2 3/4 ______ 35CP3004 350P3006 1.38 200 400 0.1 1.63 100 200 0.2 1 35CP3010 1.75 60 120 04 1-1/4 1-1/2 CP3012 35CP3014 2.00 2.19 35 - 70 50 0.5 0.7 26 2 35CP3020 2.62 15 30 1,2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number ____ A in Packing Weight lb Inner Master x 1/2 35H83010004 1.06 180 360 0.2 1 x 3/4 35H83010006 1.06 180 360 0.1 1-1/4x1 35H83012010 119 90 180 0.2 1-1/2x 1 35H83014010 1.25 75 150 0.4 1:1/2 x 1-1/4 - 35H83014012 125 75 150 0.3 2x1 2 x 1-1/4 35HE33020010 35HB3020012 1.38 40 80 0.6 1.38 40 80 0.6 - 2x 1-1/2 5H83020014 1.38 40 1 80 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight - lb inner Master 1/2 35SP3004 094 600 1200 0.07 3/4 35SP3006 1.12 ____350 ____ 700 0,1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1 1.37 1 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0,4 2 35SP3020 1 1.50 45 90 0.6 "m4f-,-Of N Fig. 35RC3 - Hex Reducing Coupling Size in Part Number ___ A in Packing Weight lb inner Master lx 1/2 35R03010004 1.69 60 160 0.3 1 x3/4 1-1/4x3/4 35RC3010006 1.69 60 120 0,4 35R03012006 2.06 40 80 0.6 2x 1 (not hex) 3kC3020010 1 2.81 20 40 1.0 Fig. 35HB3 - Hex Hushing Fig. 35U 3- Union with Brass Seat Size in Nu b r A in Pa m e Packing Weight lb inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U3012 2.50 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U3020 3.12 1 6 12 F 2.4 113 SMITH-COOPER JNTERNAI]ONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwsv.rnithcooprcom COUS <e> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 1-1/2 35X3012 35X3014 1.75 12 8 24 1.4 1.8 1.94 16 2 1 35X 3020 2.25 6 12 2.8 A A Fig. 35X 3- Cross Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 3503010 1.16 110 220 0.2 1-1/ 35C 3012 1 28 140 0.4 1-1/2 3503014 1.33 50 100 0,5 2 350 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp I LT L I Fig. 35R13 - Reducing Cross Size in Part Number a A J in B in Packing Weight lb Inner Master 1-1/4 x1 35RX3012010 1.67 1,58 15 30 1.2 1-1/2x1 35RX3014010 1,80 1.65 12 24 1,4 2*1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C3— Cap Size in T Part Number a e A in Packing Weight I lb Inner I Master 3/8 35B03003 0,75 100 200 0.3 1/2 35B0300 0.75 80 F 160 0.5 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-7660076 9 FAX (323) 90-4456 0 ww.srnithnoper.com 114 I. Insert the appropriate nut driver into a 3/8' or 1/2"porteble drill. Insert the SAMMYV into the #14 (black) not driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member, Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove, The SA MM VS is now ready to receive 1/4", 3/8', 1/2' or metric all thread rod; bolt stock. (The 1/2" requires the #14S W red nut driverj Note: When installing D$TR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for rnaximurnpullout in purlin steel. I11!IikT. Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #I4SW(reri) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4, The unit is now ready to receive 1/4', 3/8', MW, M8 or metric all thread rod or boll stock, Note: When installing SWOR, follow the above instructions, then add retainer nut and torque 1o20 foot lbs, for maximum pullout in purlin steel, [INSTALLATION STEPS INTO CONCRETE: 1, Using an SOS 250 carbide tip bit era HEX RECEIVER with a #250 carbide tip bit, pm-drill the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite and (see Vertical Installation note above. Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin Insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill, 5, The concrete screw is ready to receive 1/4', 3/8, 1/7, or metric all thread rod orbolt stock. (#14SWred nut driver used with 1/2" screw) Note: Use a; 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in Impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - 01j INTO CONCRETE: Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre -drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill, The SWC screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact made - doing so will destroy the pullout factor of the fastener, IRUN,i1iki1r1u. SPECK OJT ORM SYSTO, The nut drivers were designed with aurique epinroif feature which provides a fast and safe Installation each time, When the face of the driver comes into contact with the material you are installing into, continue drilling until nut diver spins free, Installation is then coniplete. Warranty requires the use of the appropriate nut diver for Installations, SAMMYS0 FOR WOOD Ii! No predrilling required. Quick to Install using the Sammy Nut Driver with an (By cordless drill/driver. Saves time from traditional methods, Reduces installation costs. Made in the USA Welch a video demonstrolion lc www.ttwbuitdex.com i - 4(4 Black Nut Over Part# 8(13910 1 W14 WY 00d 1(4' 8002967 GST 100 114x I" 25 125 1/4' 8003957 031200 1/4x2 1760 (Fir) 25 125 1/4' 8004957 051300 1/4i3" 2060 (Fir) (711T OSS) 25 125 3/8w 8007957 GOT 10 1/4 x 1 300 25 125 670 1760 (Fir) - 210 3/8' 8008957 03120 114x2 850 1475 25 125 3/8 8068925 GST2OSS 114x2 760ir) 850 25 125 3/9 8009925 GST25.380 318 x2-112 2113 (Fir) 1500 25 125 = 3/8 8010957 GST3O 1/4x3 2060 (Fir) 1500 1475 - 25125 3/8' 8069925 GST30SS 1f4x3 2060 (Fir) 25 125 3/8' 8011925 GST4O 1/4x4 2180 lFir( 25 125 1/2' 8013925 0512 1/42' 1760 (Fir) 25 125 8014925 GST2,5-380 3/8x2-1/2' 2113 (Fir) 25 125 1/2" 9015925 0513 1/4 x3 2275 (Fir) 25 125 M MA -f OWEN V Ec**s I'M oRvas'srui The nutthvera were designed: with a unique spin,-off faaturewhich provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing Into, continue dlllinguntil nut driver spins, free. installation is then complete Warranty requires the use of the approphato nut dhver for Installations, Black Driver - Part# 8113500 a" 'edfl279t9 FS: ~AjW? ~ ~ Not less than 2" nominal width (1.1/2') up to 1/2" pipe; not lam than 3" (2-1/2") nominal width 4" & 5 pipe 44 Al Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bet- torn for main lines. Exception: This requirement shall not apply to 2 or thicker nailing strips resting on top of steel beams. No pre-drilling required. Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless drill/driver. * Saves time from traditional methods. Reduces installation costs. I •Made in the U.S.A. OWatch a video dmoc*adoo at - iwrnitwbulldexcom r tM - 3/ 3/8"" - - - -- 3/8 8020957 - MG 16 1/4x1" 622ir)300 125 8021957 SWG20 114x2" 1725 (Fir) 1850 25 125 8073925 SWG2OSS 1/4x2 1725 (Fir 850 25 125 8022925 SWG 26-380 3/8o 2-1/2" 2249 (Fir) 1500 25 125 8023925 SW63U - - 1/4x3" 1884 (Fir) 25 - 125 Pa"* 80010 May require preArillinT, consult jotut manufacturer. Eliminates distortion of threaded rod. Accommodates up to 31/2 x 12 pitch roof, Allows 17" deflection from vertical. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. 3/8" 8139957 $P4-ST 20 114 0 21 1257 (Fir) 1050 1475 25 "" 3/8'--8141957 SH-GST3O - 1/431720)0O 1475 - 25 1903 Dim. Lumber 1500 318" 8269957 SH-GST/CSI 20 5/16 a 1-3/4" 1406 @ 45"off vertical 25 Dim, Lumber 903 Dim. Lumber 1/2" 8303967 SH-GST/CST2,0 5116x1-314" 1406©450v0rtic21 25 Dim, Lumber May require prs.drilllng; consult joist manufacturer. at 126 125 125 125 Made with Teks "If-drilling fasteners - no pre-drilling required. Installs Into steel range from 20 gauge - 1/7 thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sarnmys Nut Driver with an 18V cordless ddll/ddver. 'A standard screwgun with a depth sensitive nosepiece should be used to install Teks, For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. 'Made in the USA. Watch a video deoiontcaIion el wwwitwbu!Idorcom [SAMMYS FOR STEEL 1/4" 8024957 DSTR 100 1/4-20 x TEJ(S 3 1510 (20 ga.) .036-20 ga 3/16 25 125 1/4 8025957 DST100 114-14x1 TEKS3 446 (2093) .036"-20 ga 3/16 25 125 1/4" 8026957 DST 150 1/4-14x1-1/2"TEKS3 970 (16gt).036"-20ga 3/16" 25 125 - 1/4" 8027957 DST 200 1/4-14x2"TEKS3 446 g .036:209a - 3/16" 25 125 1/4' 8030957 TEK500 12-24x1-1/2"TEKS5 3125 (3/16") .188"-3/16" 1/2" 25 125 [3"> 3/88038957 01 11420x1 TEI<S3 1510 (2o _1500 1475 .036"-20 gs 3/16 - 25 125 - 3/8' 8037957 DSTR 1-1/2 * 12-24x11/2tEKS 5 1:510 (3/16") 1500 1475 - .060"-1&ga, 1/2 25 125 #14 Black '" 3/8 8039957 DSTR5IS 5/16 18x11/4 TEKS3 20 (209a)ibO 1475 - 036 20--ga 3/16 25 125 Nut pa iV3io 3/8" 8040957 DST 10 1/4-14x1"TEKS3' 446 (20 .036'.20 ga 3/16" 25 125 3/6" 8077925 DST 1(-SS 1/4-14 Xl" TEKS 3 446 (20 ga.) 970 (l6ga.) 036"-20 ga 3/16" 25 125 3/9" 8041957 DST 15 1/4-14 a 1-1/2" TEI(S 3 446 (20 .036"-20 93 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14x1-1/2TEKS3 446 (20 .036"-20 ga 3/16" 25 125 3/8 8042957 DST 20 1/4-14x2"TEKS3 446 (20 036"-20ga 3/16" 25 125 3/8" 8043957 DST 25 1/4-14 x 2-1/2" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8044957 DST 30 1/4-14x3"TEKS3 446 036'-20 ga 3/16" 25 125 3/8 8045957 05T516 5/16-ISXLI/4 TEKS3 1500 (36( 1500 1475 .125"-V8" 3/6 8046957 TEK 50 1224 xl 1/2' TE}(S 5 3125(3/16) 1500 1475 .250'-114" 1/2 25 125 1/2" 8031925 DST 2.0 - 1/4-14x2"TEKS 3 446 (20 .188"'3116" 1/4" 25125 1/2" 8033925 DSTR 1,0 * 1/4-20 xl' TEKS 3 1510 (20 ga.) .03&"-Z0 ga 3/16" 25 125 1 1/2 8034925 DSTR5.16" 5116-18x1-1/4"TEKS3 2220 (2098.) ,036"-20 ga 3/16" 25 125 1/2" 8035925 0S15.16 5/16-18x1-1/4TEKS3 1500 (3/16") .125-1/8" 3/16' 25 125 *145W Red -"W 1/2" 8036925 TEK5 -. 12-24x1-1/2"TEKS5 3125(3/18") I88-3/W 1/2 25 - 125 Diy*r - - -- --. ---. ----- ---------. ---------- --------- - - - P*8fl49i0 lnClUd5 retaining nut --Q SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation ONVA MAK19_____ each time. When the face of the driver comes into contact with the material you are instating into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for Installations. Made with Tekse self.drilllng fasteners -no pro-drilling required, 10 Installs into steel range from 20 gauge - 1/2" thicknesses. 'A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the scrowgvn should be a r !-9 minimum of amps and have an RPM range of 02500. Saves time from traditional methods. Reduces installation costs. 'Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Watch a v,dea dernonaUat,on at Made in the U, $A, wwwMwbuffa'ex.com 1091:41c(41191W "Ilium 1/4" 8047957 SWO 100 1/4-14 x TEKS 3 1477 (16 ga.) .060'-16 ga 3/16' 25 125 1/4 8049957 SWQR 100 1/420 xl TEKS 3 1900 (20 9a) .036"-20 ga 3/16 25 125 3/8' 8090957 SWD 10 114-14 a 1' TEKS 3 1477 (16 ga.) .060'-16 ga 3/16" 25 125 318 8080925 SWD 10-SS 1/4-14 a TEKS 3 1477 (16 ga.) - .060'.169a - 3116* 25 125 3/8 8051957 SWO 15 1/4-14 s 11/2 TEKS 3 1477 (16 gal - 060"-115 ga 3/1-61 29 125 3/88052957SW020 1/414 x2'TEKS3 1477(169a) --.060"-16 ga 3/16 25 125 3/8' 8053957 SWD516 5/16-18x/-1/4' TEKS 3 2480 (20 ga.) .036"-20 ga 3/16 25 125 3/8 8055957 SWDRI 1/4 20x1 TEKS3 1900 -6 ga— iso5 - - 1475 036 209a 3/16 - 25 125 $t4WRe4 .)-' 3/8' 8054957 SWOR 1-1/2 " 12-24 a 1-1/2"TEKS 5 2375 (3/16' 1500 1475 .188'-3/16" - - 1/2' 25 125 3/8" 8056957 6WDR516 5/16-18 a 1-1/4 TEKS 3 2480 (20 1500 ga.) 1475 036'-20g8 - 3/16" 25 125 3/8' 8057957 SWT 15 12-24 * 1-1/2' TEKS 5 ----- 2375(3/16') .188"-3/16" 1/2" 25 125 includes retaining nut Application Product Features N • Eliminates distortion of threaded rod in sloped roof applications. 'Accommodates 3-1/2 x 12 pitch. installs into angled z-pudin; allows threaded rod to hang plumb. 'Allows 17' deflectIon from vertical. Made in the U.S.A. (j,wwwMwbuiIdeLcom) rJrApprovals Part Model Screw Ultimate UL Test FM Test Min Max Box Case ii ad (lbs) Thick Thick City City Nut Driver f 318' 8137957 SR-OSTR 1' TEKS 3 3220(3/16) 1500 1475 035" 3/16 25 125 Part#81138101 2368(1/2' steel Vertical) ' 3/8" 8268957 SI'4-TEKSO 12-24*1-3/4° 1306(45 off Vertical) 1500 (Vertical) ' 3/16 1/2' 25 125 TEKS 5 2281 (3/16' HSS) 850(45' off Vertical) 2-1/2 1585(3/18 HSS 45" off Vertical) 2368(1/2' steel Vertical) 112' 8270957 SH-TEI< 5.0 12-24*1-3/4 1306 (45' off Vertical) 3/16" 1/2" 25 125 1585 (3/16" H 5 45 off Vertical) 'Does not comply with R0Hquirnegits/lnrIucieoratolnInnot F SA WPRE SS" Installs to Metal Deck, Purl/n, or Tubular Steel The Sammy XPvess expands to provide direct vertical attachment in: light gauge steel deck or puriin (22 ga. - 1/B"). Installs in seconds with Sammy X.Press It' Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tabular steel, or vapor barrier fabric, Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Watch a atdeo demonatration at wwwJtwbulWex.com 114" 8181922 XP 200 Sammy1148 (229a) 185 (Luminaire) .027' 125.125 125 Metal Deck X-Press 200 250 (Luminaire) .056" 850 (2W Pipe) .027" 940 (2" Pipe) 029" 3 <' 3/8" 8150922 XP 20 Sammy xo 1146122901 185 (Luminaire) 250 (Luminaire) 15T 1475 (4* Pipe) :104" .125" 25 125 Metal Deck 263 (Conduit & Cable( .029 1500(4" Pipe) .060" 9€> 3/8" 8153922 XP 35 Sammy 18 (Lumineire) I78316ga1 , 940(Pipe) .125" 25 125 Put/n XPress 250 (Luminaire) .066 1475 (4" Pipe) 104' 416 (Conduit & ca/tel .059" r Pre-Pour Structural Concrete@ 3000 pal MlitalDeck " 3/8 8150922 XP 2a Sammy1146(22ga) 850 12'/z Pipe) 25 125 (Pre-Pour) L x ress 20 Post-Pour Range II LWC:5 35 PCF (lbsift'( Metal Deck •• ---•----- -- . Pre-Pour structural Concrete @ 3000 pat Poet-Pour Range It LWCS 35 POP (IbsI ft") * The $fdewtnderX-Press expands to provide "Lass. jobsite material needed. horizontal attachment in: - 16 g - 3/16" steel - purlirt, tubular steel. "Na retaining nut required. Installs in seconds with Sammy X,-Press 10 Tool, • Provides design flexibility. saving time & installation costs. Made in the U.S.A. "Use in applications where access to the back of the installed fastener is prohibited; is. metal roof (SWXP) deck, tubular steel, or vapor barrier fabric. Watch a video demanotration at www.ltwbuikIex.com Sidewinder t' Pl 9 3/8" 8293957 SWXP 35 X-Press 35 1798 (16 gel 80 (Luminaire( 059" .125" 25 125 Put/n MMYS .027" .125' 25 125 Metal Deck The SwIv&XPress allows you to hang plumb in extreme roof pitches: 8" In zpurtin -45' in metal deck for 12/12 pitch Installs in seconds with Sammy X.Press le Tool, saving time & installation costs, Use in applications whore access to the hack of the installed fastener is prohibited, ie. metal roof deck, tubular steel, or vapor harrier fabric. 'Less jobsite material needed. No retaining nut required, 'Provides design flexibility. Made in the U.S.A. Watch a video demonstration at .' www.itwbulldex.com 750(2" Pipe) . 170 Vertical (Lurninaire) 3)8' 8294922 SXP 20 Swivel 80 @ 45 )Luminaire) .029" 635 IT Pipe) .029" .125' 25 125 Metal Deck 283 Vertical (Conduit & Cable) 233 @ 450 (Conduit & Cable) 1250 (3-1/2' Pipe) Swivel 1675 (16 ga Vert) 250 Vertical (Lurninaire) 4. '€ 3/8' 8295022 SXP X-Press 35 35 1558 )8 Off Vert)80 @ 90' (Lutninaire) Cable) 059" 635 (2' Pipe) .029' .125" 25 125 Purlin 500 Vertical (Conduit & 333 @ 89" (Conduit & Cable) 1/2' 8272957 SXP 2,0 Swivel 1061(22gaVert) X.Press 2.0 829 (45" 0ff Vet) 1/2" 8271957 SXP3.5 Swivel 1675 (16 ga Vet) X-Press3.5 1558)89" Off Vel't) .060' .125" 25 125 Purtin , I The SammyX.Press expands to provide direct vertical attachment in: metal deck (22-16 gauge) z-purlin (18-16 gauge) Made in the U,S.A. Watch a vidac IM 57,10 TPart Number I 8194910 - IJXPIT" - Universal X-PressltTool 8162910 XPDB 25/64" Drill Bit 'Tool Includes: Sleeve, Bit Receiver, Hex Wrenctr, and 25/64' Otill Bit APPROVALS 8007957 GST 10 3/8 Vertical CPVC 1-1/2" Wo 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" $00 1-1/2" 8008957 GST 20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST 20.55 3/8' Vertical 2-1/2" 850. 1.1/2" 8010957 05130 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" 8009925 08125-380 3/8" Vertical 4' 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-1/2". 4' 1500 1-1/2" 8021957 $WO 20 3/8" Horizontal 2-1/2" - 3` 1050 1.1/211 8073925 SWG 20-55 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SHGST/C$120 /8" 48' Angle off Vertical 2.1/2" 850 1.1/2' 8269957 SH-GSI/CSt20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-0S720 3/9 lr Angle off Vertical 1050 1.1/2" 4" 1475 1-1/2" 8038957 DSIRI 3/8" Vertical 4' 1500 035" 4" 1475 AN 8037957 DSTR 1.1/2 3/8" Vertical 1500 .035" 4" 1475 .105' 8039957 DSTR 516 3/8" vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4' 1475 .188" 8046957 ' IEK5O 3/8" Vertical 4" 1500 .259' 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR1 3/8" 17° Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SHTEK50 3/8" Vertical 2.1/7' 850 70" Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 4 1475 .125" 8294922 SXP 20 3/8' Vertical or up to 45" 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 890 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE. PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 , 3/8' Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 650 Pre-Pour Structural @ 3000psl 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC :s 35 PCF (lbs/ft°) 8150922 XP 20 3/8" Vertical 185 027" 250 .035" 8153922 XP 35 3/8" Vertical 185 25) : 8181922 XP 200 1/4 Vertical .027'cal 250 035" 8294922 SXP 20 3/8" Vertical ITO 8295922 SXP 35 8" Vertical 250 .060" 90° 80 .060" 8293957 SWXP 35 3/8" horizontal 80 .060" Part Rod Number Model MountSize Direction • Istedrungirrur.ii 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060° Max 4 trade size EMI & 6 trade sze RMC, lMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and iMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/6" Vertical 500 .060" Max trade size EMT & 8 trade axe RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060' Max 4 trade size EMI & 6 trade axe RMC, IMC, and rigid PVC conduit 8149957 0Z2000 1/4" or 3/6" Onto Vertical Rod U'L Listed 4S16 -Cable Ranger, Cat. No. C42000 Plenum Rated, Sheet Steel Gauges Complies w/ NEC Standards Gauge No, 22 q& 20 p. Is P. 168a0 14ga. 12gL 1/8" 3/16' 114" Nominal DeclmatEquivalent .030' .038" .048" .060" .078' 105" .128' .188" .250" SWG 25-380 Maximum pipe size in composite wood joist allowed by UL Is, 3-112 SWG 25-380 Maximum pipe size in wood 5mbsror Inlet allowed by UL1 UL compliance with NEC Standards *'$Wr. 20 Maximum pipe doe in compornta wood joist allowaotby li is 2-1/2 UL and Plot taste were perfrmd in compliance with NFPA 13 Standards SW( 20 Mnuimum ninesim in o-m'oi lin,n,+ h ii , 5 Fastening requirement; 5 times weight of water.efled:schedule4e pipe p1uw250 pounds. SPECIAL NOTES Engineering Note In 1996 the anchors listed by UL were tested in plate steel that measured 188 and 118 Subsequent testing was done forz purhn applications in May 1997 using (037) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Prese was completed using (.030") or 22 gauge steel metal deck. Sammys Nut Drivers Special nut drivers were designed to be used with Sammys When the appropriate nut drivers are used for Installation the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Stool Screws Due to variations In hardness of certain metals it should be noted that our self-drilling screws for steel will experience different drill speeds 500-1600 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www,itwhuildex.com Sammys for Seismic Please visit www,ltwbulldex.com for our current Seismic product offerring, Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments special care should be taken not lust for building attachments but also for the hangers or assemblies being supported Consult local code authorities for accepted anchoring devices Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25.380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended Installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table beloer Model Root Diameter Hole Size GSI20 .182" 1/8" GSI 25-380 .280" 7132" SWG 20 182" 118" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling, NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com PflHANIER LEBO AS CONOO MO CABLE tERtS*M go, Technical Drawings Technical drawings are available and can be downloaded at wv,itwbuildex.com in the following formats: 4wg, .dxf, and .igs. Made in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. Listincls/ADDrovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor 3 1 N,4 ~ ~"~ 41i IndeDendent code evaluation lBC®/ IRC® 2015 IBC®/ IRC® 2012 IBC®/ IRC112009 IBC®/ IRC®2006 Hilti, Inc. (US) 1.800.879.8000 1 www.us.hitti.com I an español 1-800.879.5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dblt in. 1/4 Nominal embedment hnom in. 1-5/8 2-1/2 Effective embedment h f in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T Inst ft-lb 18 (Nm) (24) Wrench size in. 7/16 1 T t is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' .2,3,4,5 Nominal Nominal Tension - N5 Shear - anchor embed. f' = 2,500 psi f' = 3,000 psi f', = 4,000 psi f, = 6,000 psi f, = 2,500 psi f' = 3,000 psi f'c = 4,000 psi f, = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 / (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concret&''3'4'5 Nominal Nominal Tension- 1\15 Shear - On anchor embed. f' = 2,500 psi f' = 3,000 psi f = 4,000 psi f' = 6,000 psi f' = 2,500 psi f',= 3,000 psi f',=4,000 psi I,, = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 / (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) 1 (8.9) 1 (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A5 = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1.5/8-in nominal embedment depth - aN = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNC = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile' Shear' Seismic shear4 diameter thread diameter qN V. 4\/Sa in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension tpN = as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4V,5 < 0.64A,0 f, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with 5 0.60 A55 v f,, as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete 1,2 Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear3 uncracked concrete fRN 'AV fRy fRy I HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1 1.00 0.60 _______ 1.00 n/a n/a 8 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 _______ _______ 0.71 0.64 _______ 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 Ca 10 (254) 0.89 0. 11 (279) 0.93 12 (305) 0.97 - 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete" Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear3 cracked concrete f 'RN 'AV fRy 'RV 'MV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 81 E 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4.1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 1~5 21 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 _6 (152) 1.00 0.86 0.74 0.98 7(178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9(229) 1.00 0.86 Cn 10 (254) 0.90 11 (279) 0.94 12 (305) 0.98 - 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, fAv assumes an influence of a nearby edge. If no edge exists, then I A, = IAN 4 Concrete thickness reduction factor in shear, f, assumes an influence of a nearby edge. If no edge exists, then fHV = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. 13~ Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension -ON~ Shear - OVn Tension - 4N Shear - anchor thread embed. f'= 3,000 psi f'= 4,000 psi f'= 3,000 psi f= 4,000 psi f'= 3,000 psi f'= 4,000 psi f 3,000 psi 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 1 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - ON Shear -4V Tension - N,, Shear - _pV anchor thread embed. f'= 3,000 psi i'= 4,000 psif'= 3,000 psi "= 4,000 Ps f,= 3,000 psi f'= 4,000 psi '= 3,000 psi '= 4,000 Psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 1 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) / ______ 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,e = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Huh, inc. (US) 1-800-879-8000 1 www.us.hifti.com I en españoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca i Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Min, 3/4" ,- Mm 3000 sl sand h ' 6 , or normal-weight concrete k,,r-,) Upper flute 20 0auge steel deck 4,2 LAnchor (typicO flute / Flute edge Lower j Mm. 1-1/4" - -___ Mm, 12' (typical) I Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. II 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in [CC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hiltLca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile3 Shear4 Shear4 diameter diameter N V V in. (UNC) wr lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = A N fut~ R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V < cp 0.6 f R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V, <A 4 0.6 f, R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hihi.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1.800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. d in. 1/4 (mm) (6.4) Effective embedment2 In et in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 2-1/2 h nom in. 1-5/8 (mm) (41) (64) Minimum concrete thickness In in. 3-1/4 4-1/8. (mm) (83) (105) Critical edge distance c0 in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance Smincac in. 1.5 (mm) (38) Minimum edge distance c mjn in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 (mm) (51) (73) Minimum specified ultimate strength f.a psi 125,000 (N/mm2) (862) Effective tensile stress area A N in 0.045 (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 Factored steel resistance in tension N r lb 3,370 D.6.1.2 (kN) (15.0) Factored steel resistance in shear V lb 750 D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic Vsar (kN) (1.5) Factored steel resistance in shear V lb 725 D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic Vsar (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k ancr - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete kccr - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc .4 tPcN - 1.0 D.6.2.6 Anchor category - - 1 D.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete6 N lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete Nprc, lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete NP, lb 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from [CC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. For all design cases, q) = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,) or uncracked concrete must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qj = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in uncracked concrete 1,2.3,4,5 Nominal __________ Tension - N Shear - V f', = 20 MPa f', = 25 MPa f' = 30 MPa f', = 40 MPa I' = 20 MPa f' = 25 MPa f' = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 1 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in cracked concretelZ345 Nominal ___________ Tension - N Shear - V, f', = 20 MPa I = 25 MPa I', = 30 MPa f' = 40 MPa I,, = 20 MPa f = 25 MPa f'c = 30 MPa I',, = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1/4 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - sels = 0.75 See section 3.1.8.7 for additional information on seismic applications. 3.3. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hifti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hUti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N Shear - V Tension - N Shear - V anchor thread embed. I = 20 MPa f'c = 30 MPa f' = 20 MPa f, = 30 MPa I = 20 MPa f' = 30 MPa I = 20 MPa I = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 / UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1,Z34$e7.8 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N Shear - V Tension - N Shear - Vr anchor thread embed. f', = 20 MPa f'c = 30 MPa f', = 20 MPa 10 = 30 MPa I = 20 MPa I = 30 MPa I = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,.,,, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 U 1-5/8NC 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Huh, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an españoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete Danel&' Hanger rod size Mm. effective embedment h9 in. Allowable load' Ultimate load Tension lb Shear lb45 Tension lb Shear lb 4,5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 Installation of Will KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 3.3.7.6 installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty I box KH -EZ 1/4x1 -5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 11/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 I 3/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/40 (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange whore clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California 031-f PD Approved c Vt. us LISTEDSeismio Restraints System Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* WIJ100 3/8 1/ie 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1. 9/16 11/4 1130 55 Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F LoadLbs* WtJiOO 3/8 iVi 11/4 1 7/16 1 610 28 1/2 1½ 1114 1 9/16 11/4 1130 55 5/8 1½ 1¼ 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. D OFRCE/MANUFATURIN6 FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92979 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 900.780.5268 www.tolcu.com Fig. 25- Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe Material - Pro-Galvanized Steel Function - Designed to be used In conjunction with TOLCOS Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake typo activity. The surge restrainer Is easily and efficiently Installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edItion, 9.2,3.4,4,1 and 9.2.3.4,4,4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig, 2, 2NFPA and 200, in the USA (UL) and Canada (cUL. Finish - Pro-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-UNE 1375 Sampson Ave • Corona, CA 92879 9 800.786.5266 • FAX: 951.737.0330 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98- Rod Stiffener Component of State of California OSI-IPO Approved c as WillSeismic Restraints System Size Range Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seimic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - AM Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750° F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F WtJ100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92819• P11: 951.137.5599 • FAX: 951137.0330 CUSTOMER SERVICE . 800.786.5266 www.10Ica.coi, Fig. 200$ Fig. 200 - "Trimline" Adjustable Band Hanoer (Cooner B-Line Flo. B317ONFI TCLcD Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Une Fig. B3170NFF) C • YL Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) USM US Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut FM Size Range: Fig, 200 1/2 (15.'r.m) thru 8" (200rm) pipe Material: Steel, Pre-Galvanized to 090 specifications Function: For fire sprinkler and other general piping purposes. Knurled .-. swivel nut design permits hanger adjustment after installation. - Features: (112" 5'ir thru 2" 50rirn,) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design •'' , keeps adjusting nut from separating with banger. Hanger is easily 44 B installed around pipe. A -. For hanger with non-captured nut order Fig. 200S. - (21/2' 65- thru 8" (200'rr)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. . -- Approvals: Underwriters Laboratories listed (½" 15rnm thru 8" l200imi) Fig 20G/z 200-/4 in the USA (UL) and Canada (cUL) for steel!and PVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/ i20r--r? thru 8 (200rm). Fig. 200-1 to 200-2 Fig. 200-21/z to 200-8 Conforms to Federal Specifications WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58. Type 10. Maximum Temperature: 650"F 3431C Finish: Pre-Galvanized. Stainless Steel / materials will be supplied with (2) hex nuts / in place of a knurl nut. Order By: Figure number and pipe size f Designed to meet or exceed requirements of FM DS 2-0. Fig. 200 Fig. 200C Fig. 200F Pipe 1/2" ' (15) Rod fjp' /a'-16 (794) Approx. Wt./100 ERi 200-I4 3/4" (20) /811-16 31/8' (79,4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) I8'-16 33/6" (85,7) 2/8" (66.7) 12 (5.5) 200.11/4 11/4" (32) /8"-16 33/4" (94.0) 2fs" (73.0) 13 (5.9) 200.11/2 11/2" (40) J 3/a"-16 37/8" (98.4) 2/8' (73.0) 14 (6.4) 200-2 - (50) /e"-16 41/2 (114,3) (76.3) 15 (6.9) 200_2112 21/2" (65) /"-16 55/8" (l42.9 41/g" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) 200_31/2 31/2" (90) /"-16 73/8" (187.3) 51(4" (133.3 34 (15,6) 200-4 4" (100) /"-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5' (125) 1/ 91/8 (2318) 61/4' (1587) 66 (302) 200-6 6" (150) 1/2"_13 101/8k (257.2) 61/4" (171,4) 73 (33,4) 200-8 8" (200) 11/2'-13 131/8" (333.4) 1/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown In parentheses are In millimeters unless otherwise specified. op- to COOPER B-Line Fig. 2C0-211z to 2004 Fig. 200M - "TrimUne" Adjustable Band Hanger for Metric Rod Size Range; Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material; Steel, Pro-Galvanized to 090 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation, Features; (1/2" (15mm) thru 2" 50mm)) Flared edges ease installation for all pipe types and protect CPVG plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger, Hanger Is easily installed around pipe. 21/2" (65mm) thru 8 (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed, Approvals; Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) In the USA (UL) and Canada (cUL) for stool and CPVC plastic pipe and Factory Mutual Engineering Approved I4" (20mm) thru 8" 00mm)). Conforms to Federal Specifications WW-H-I 71 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10, Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized, Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Part1fti. 200M8-1/2 ,I1 1/2 (15) MS 31/g' (79.4) Approx.Pipe V1Wi .. 2I9 (66.7) I 11 (50) 200M10-1/2 1/2° (15) M10 31/8" (79.4) 2I8" (66.7) 11 (5.0) 2000018-3/4 3/4° (20) M8 311" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4° (20) MID 3118 (79.4) 21/2" (63.5) 11 (5.0) 200M8-1 1° (25) MS 33/g" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1" (25) MID 3318° (85.7) 2/8' (66.7) 12 (5.5) 200M8-11/4 11/4' (32) MS 3/4" (94.0) 2f" (73.0) 13 (5,9 200M10-1114 11/4° (32) MID 3314" (94.0) 2/" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) MB 37/8" (98A) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) MID 37/8' (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 2" (50) MB 41/2" (114.3) 3' (76.3) 15 (6.9) 200M10-2 2" (50) MID 41/2" (1143) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) MID 55/0" (142.9) 41/s" (104.7) 27 (12.3) 200M-3 3" (75) MID 57/g" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) MID 73/i" (187.3) 51/4" (1333) 34 (15.6) 200M-4 4° (100) MID 73/g" (187.3) 5" (127.0) 35 (16.0) 200M-5 5° (125) M12 9118" (231.8) 61/4" (158.7) 66 (30,2) 200M-6 6' (150) M12 101/8" (257.2) 6/4" (171,4) 73 (33.4) 200M-8 8 (200) M12 131/8" 1 (333.4) 83/4" (222.2) 136 1 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size flange; 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pro-Galvanized to G40 Spec Function; Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size, Used extensively to support trapeze installations and the increased toads from both above and below the trapeze assembly. Features: Furnished with /6"-16 or /213 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed In the USA (UL) and Canada** cUL. Conforms to Federal Specification WW-H-1 71 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10, Maximum Temperature: 650°F (343°C) Finish; Pro-Galvanized Order By; Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 200H-2-3/8 Pipe Size 2 (50) Rod Size 3/s"-16 A B jj tT i_€ia_r . 4I16 (115.9) 37/32 (81.7) .ii.Y Jti 48 11 I (21.8) 200H-2-1/2 2" (50) 112°-13 42 /32° (119.8) 33f" (85.7) 45 (20.4) 200H-2112-318 2/2° (65) 4-16 55/16 (134.8) 323/32° (94.4) 59 (26.7) 200H-21/2-1/2 21/2° (65) 1/2°_13 515/32° (138,9) 3fa" (98.3) 56 (25.4) 200H-3-3/8 3° (75) Ig°-16 53/411 (146.0) 327/32 (97.6) 63 1 (28.6) 200H-3 1/2 3" (75) 1/2°_13 57/s" (148,1) 331/321, (100.8) 60 (27.2) 200H-4-3/a 4° (100) I8°-16 6/a° (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4° (100) 1f2H_13 71/32° (178,6) 419/32° (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8° pipe at max spacing per r4FpA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches, Dimensions shown in parentheses are In millimeters unless otherwise specified. PP_ so COOPER B-Line All dimensions In charts and on drawings are In inches. Dimensions shown In parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 182 B-Line by 74 Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - I811 -16 to /411-10 rods Component of State of California OSHPD Approved Fig. 980H - Universal Swivel Sway Brace Attachment - 7/"_9 to 111411_7 rods seismic Restraints System Size Range: One size fits bracing pipe 1 (25mm) thru 2' (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31,7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting, Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections, NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation; Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe", Tighten the set screw until the head breaks off, Attachment can pivot for adjustment to proper brace angle. Approvals: -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering FM), Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note: Fig, 980 Swivel Attachment and Fig. 1001, Fig, 1000, Fig. 2002, Fig. 4A, Fig. 4B or Fig. 4L pipe clamps make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. US Patent Numbers Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 cU3 Lwal SitSaruw ImUld Mounting Hrdwir 1Nfltlno1ud4d ( * Mounting attachment hole size. Installed with 1" or 11/4" Schedule 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-tine's warranty for seismic bracing components will be the warranty provided in B-Lire's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. k 11!i $et 5crr TOLCO TM Seismic Bracing Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2" (50mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 2/2" (65mm) through 8" (200mm) pipe. Approved by Factory Mutual Engineering (FM), 2' (50mm) through 8" 2Q0mm) pipe. Installation Instructions; Fig. 41 is the 'braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the 'bracing pipe' and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig, 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and raterfal, Order By: Figure number, pipe size and finish, %n 4Way ace (plan V ' -s Longitudinal Brace -'--r Part Size A C Max.Pipe I 1 Bolt Size 1/13 2015 - • I (6.96) 1 A Design ILoad TApprox. P 2412.0) 4L-21 I2 21/2 (65) 6/1" (163.5) 2/2 (63.5) 2/4 (69.8) 1/2 .13 2015 (8.96) 3000 (13.34) 253 (114.7) 4L-3 (60) 7' (177.8) 2/4" (69.8) 31/16" (77.8) 1/2 .13 2015 (8,96) 1550 (6.89) 268 (121.5) 414 (100) 81f2" (215.9) 3/8' (85.7) 3/16" (93.7) 1/2"..13 2015 (8.96) 1550 (6.89) 348 (157.8) 41-5 (125) 93/4" (247.6) 37/8' (98.4) 4I8' (111.1) 1/2 .13 2015 (8.96) 1450 (6.45) 380 (172.3) 4L-6 6' (150) 111/2" (292.1) 5" (1270) 5118" (130.2) 1/2"13 2015 (8,96) 1450 (6.45) 640 (290.3) 41-8 8" (200) 131 /4" (336.5) 5 /8" (142.8) 5/8 (142.9) 1/2 .13 2015 (8.96) 1450 (6.45) 728 (330.2) Part Pipe Size Max. Rec. I*f, (WLuc) 3G-44' I Design ' , Load 41_.21/2 21/2" (65) 2015(8,96) 1030(4.58) 1180 (524) 1420(6.31) 1590(7.07) 41-3 (80) 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) 41-4 (100) 2015 (8.96) 530(2.36) 730 (3.25) 890(3,96) 990 (4,40) 41-5 (125) 2015(8,96) 530(2.36) 730(3,25) 890(3.96) 990(4.40) 4L-6 (150) 2015(8.96) 530 (2.36) 730 (3.25) 890(3,96) 990(4.40) 41-8 8" (200) 2015(8.96) 490(2.18) 680(3,02) 830 (3.69) 930(4.13) * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 11/4", 11/2" or 2" Sch. 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resting In a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business rakes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches, Dimensions shown in parentheses are In millimeters unless otherwise specified. Pipe Hangers & Supports B4ine by 7j Seismic Bracing TOLCOTh Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 1' l2mml thru 8(200mm) (PS. * Pipe size used for bracing: 1°)25mm) and 11/4 132mm) Schedule 40 (PS. Material: Steel Function: For bracing pipe against sway and seismic disturbance, The pipe attachment component of a sway brace system: Fig 1001 is used in conjunction with a Fig 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly, Features: Can be used to brace schedules 7 through 40 (PS. Field adjustable, - making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe, Can be used as a component of a four-way g3i riser brace. Comes assembled and ready for installation, Fig. 1001 has built-in F visual verification of correct installation. See installation note below. W Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set screws until heads bottom out. A minimum of 1' (25mm) pipe extension is recommended, Brace pipe can be installed on top or bottom of pipe to be braced. - Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines, OPA-0300-10. Finish: Plain or Electro-Ga Ivan ized. Contact customer service for alternative finishes and materials. Order By: Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Component of State of California OSHPD Approved Seismic Restraints System Pipe Max. Horizontal Design Load (UL)- Lbs Size For Brace Pipe Size 1" 111/4" Sch, 7 Sch, 10 Sch, 40 in, (mm) 1"/1h/4$ 1"I1h14" 1'/111'/' 1' (25) --I - 1000/1000 1000/1000 11/4" (32) 1000/1000 1000/1000 1000/1000 11/2" (40) 1000/1000 1500/1500 1500/1500 (50) 1000/1000 2015/2015 2015/2015 21/2" (65) 1600/1600 2015/2765 2015/2765 (80) 1600/1600 2015/2765 2015/2165 (100) 1600/1600 2015/2765 2015/2765 6" (150) 1600/1600 2015/2765 2015/2765 8" (200) 1600 /1600 2015/2765 2015/2765 Set Screws Included Part Number & Appro)L WtJ100 Max. Horizontal Design Load (FM) Pipe For Sch.7,Scb.10,&Sch.40 Pipe I.Z3 Size 1" (24mm) Brace Pipe 11/4" (mm) Brace Pipe 30°-44° 45°-59° 60°-74° 75C..900 in. (mm) Lbs. (kg) I Lbs. (kg) I Lbs. (kN) Lbs. (kN) Lbs. (kNI Lbs. (kN) (25) 1001-1 X 100.0 (45.3) 1001-1X1'/4 118.0 (53.5) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4" (32) 1001-1114X1 100.0 (45.3) 1001-1'/4X1'/4 114.0 (513) 1230 (5.47) 1740 (1,74) 2140 (9.52) 2380 (10.58) 1112" (40) 1001-11/2 X1 100.0 (45.3) 1001-11/2 X11I4 115.0 (52.1) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) (50) 1001-2 X 1 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 11230 (5.47) 1740 (1.14) 2140 (9.52) 2380 (10.58) 21 /2" (65) 1001.21/2 X 138.6 (62.8) 1001-21/2 X 11/4 160,4 (72,7) 800 13.56) 1130 (5.02) 1380 (6.14) 1540 (6.85) (00) 1001.3 X 1 147.2 (66.1) J 1001-3 X 11I4 168.7 (76,5) j 850 (3.79) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 1 160.9 (73.0) 10014 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 10016 X 1 190.0 (88.2) 1001-6 X 11/4 211.4 (95.9) 510 (221) 730 (3.25) 880 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98,6) 1 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GRIT 3091,EN 10255H,. or MS 03451 steel pipe as the brace member, 2 Load rating for LW above refers to FM Approved Lightwa)I Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GRIT 8163 steel pipe. Load rating for Schedule 10 above may be applied to GR/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwail, or Schedule 40 steel pipes. Now See UL load ratings in UL Listed Design Load chart shown under drawing. Al) dimensions in charts and on drawings are in inches, Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 El-Line series Pipe Hangers & Supports Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 1500E LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ'M System Compatible Program* Certified to NSF/ANS/Std 61 -G *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 + 1800344-1822 FAX + 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, ft ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. I WW © 2012 Fire Protection Products, Inc. FPPI®, LubeFiV are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ, Blaze-Master, FlowGuard Gold5 and Corzan5 are registered trademarks of Noveon IP Holdings Corp. MADE N U.S.A. Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC' System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5g1. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com N' © 2012 Fire Protection Products, Inc. FPPI®, LubeFit(I are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMaster®, RowGuard Gold and Co,zana are registered trademarks of Noveon IP Holdings Corp. LA MADE IN U.S.A. (I1 Description ThreadFit5 CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal, It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Spears" Compatible indicates that ThreadFit5 CLEAR has been tested by Spears5 Manufacturing to be compatible with Flameguard® pipe and fittings. Nu 0 2013 Fire Protect/on Products, Inc. FPPf, ThroadRt are registered trademarks of Fire Protection Products, Inc. unaw U-LA. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBC/A SYSTEM COMPAT1BI *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Golds, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSI-IEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 - 1 800 344-1822 FAX + 1800 344-3775 Installation ThreadFit5 can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gi drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal: information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300.