Loading...
HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; ; FPC2020-0203; Permit:JI (bty of Carlsbad =emi Print Date: 01/04/2021 Permit No: FPC2020-0203 Job Address: 1950 CAMINO VIDA ROBLE, CARLSBAD, CA 92008-6599 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fixed Extinguishing Syste Parcel #: 2120931200 Track #: Applied: 11/24/2020 Valuation: $4,611,280.46 Lot #: Issued: 12/08/2020 Occupancy Group: Project #: DEV2019-0138 Finaled Close Out: 01/04/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: RAF PACIFICA GROUP FUSION Description: ALPHA TECH (ATEC) - PREACTION DETECTION AND CONTROLS Applicant: FPContractor: MISSION CRITICAL ASSET PROTECTION INC MISSION CRITICAL ASSET PROTECTION INC ERIC BEHAR 13274 WAN ESTA DR 13274 WANESTA DR POWAY, CA 92064-4624 POWAY, CA 92064-4624 (858) 776-9554 (858) 776-9554 FEE AMOUNT FIRE Pre-Action System with Alarm $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 760-602-8561 f I www.carlsbadca.gov I Ff c 2-o?,.-o -o203 I IEDD I I Mission Critical Asset Protection, Inc. I I Equipment Submittal I L ATEC - Tenant Improvement I I For: L ATEC I 1950 Camino Vida Roble I Carlsbad, CA 92008 I MCAP Job # 2841 I November 24, 2020 I I 13274 Wanesta Drive Poway, CA 92064 PHONE. 858-776-9554 CA. LIC. # 1054145 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0170 Page 1 of I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Bill Witherspoon (314) 595-6731 Fax (314) 595-6999 Email: BillW@pottersignal.com DESIGN: Model PFC-4410RC and PFC-441OARC fire alarm control units. Automatic, manual, noncoded, local, remote station, central station, releasing device, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. Minimum system components: PFC-4410RC Control Unit PFC-441OARC Control Unit with LED annunciator Suitable for use with the following modules: RA-4410RC, CA2Z, CAM, ARM-1, ARM-2, *ARM..44 and SG-32. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with separately listed voice evacuation systems. Refer to listee's Installation Instruction Manual for details. These control units do not generate a Temporal Pattern Signal. If the distinctive three-pulse Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Model PFC-4410RC control unit meets the requirements of UL Standard 864, 9th edition. Model PFC-441OARC control unit meets the requirements of UL Standard 864, 8th edition. NOTE: Combined with 7170-0328:171 L I I Rev 06-18-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. I Fire Engineering Division I I I I I Li I I I I I I I I POTTER PFC-4410RC The Symbol of Protection RELEASING CONTROL PANEL Dimensions: 18 ¼" x 14 Va" x 43/4 UL and ULC Listed, FM Approved, NYMEA Accepted, CSFM Approved, CE Marked, and RoHS Compliant. General Description The PotterModel PFC-4410RC is a flexible multi-hazard releasing control panel that is well suited for a number of applications. The PFC-4410RC is listed for use with pre-action and deluge sprinkler suppression systems and agent based fire suppression systems. The panel utilizes a microprocessor-based system that has 24 Standard Programs, which covers a majority of installations. The simple to follow Menu Structure programs the entire system in a matter of minutes. In addition to the Standard Programs, the panel allows custom programming to accommodate any installation. Ordering Information Multi-Hazard Operation Four Class B Initiating Circuits Two Class B Supervisory Circuits ** Four Class B Output Circuits Programmable Cross Zoning Supervised Microprocessor 32 Character Alpha-Numeric LCD Display Custom Banner Message and Zone Description text Custom Zone Description Text On Board Menu Driven Programming Controls Releasing Circuits Protected From False Activation Continuous or Timed Discharge 40 Event History Buffer Walktest with Automatic Time-out Alarm, Trouble Supervisory, and Waterfiow relays Optional Class A Initiating Zone and output module 34 character LED supplemental display 24 Standard Programs in Panel Memory Password Protection for all Programming 24 Hour Clock Suitable for agent or water-based extinguishing Programmable pre-discharge timers* One Class B Abort circuit* (Defaults to additional supervisory zone in water based mode.) Four Abort modes* * Available in Chemical mode only ** One zone programmable as abort in chemical mode. The panel is Tenth Edition UL listed, ULC listed, Factory Mutual, California State Fire Marshal (CSFM), New York Materials Equipment Acceptance (MEA) Approved, CE Marked, and RoHS Compliant. The PFC-4410RC is housed in a durable steel cabinet with removable door and key lock. The panel is available in either a red or white finish and an optional flush mount trim ring is available. The cabinet contains knockouts on the side, back and top of the cabinet to ease installation. In addition, the cabinet will house up to 18 amp-hour batteries that will provide in excess of 90 hours of standby power. I I I I I 1 I I I U I I I I I I Model Number Description Stock Number PFC-4410RC 4 Zone Releasing Control (Red Cabinet) 3006142 PFC-4410RC-PCA Replacement Motherboard 3006230 PFC-TR Bezel for Semi-Flush Mounting (Red) 5090155 BT-80 Battery, 12V 8AH for 24 hour standby (2 Req'd) 5130084 BT-120 Battery, 12V I2AH for 24 hour standby (2 Req'd) 5130090 BT-180 Battery, 12V, 18AH for 90 hour standby (2 Req'd) 5130086 CA2Z 2 Zone Class A Initiating Circuit Module 3006013 CAM Class A Indicating Circuit Module 3005300 ARlv144 Relay Module for PFC-4410RC 3006221 ARM-2 Auxiliary Relay Module 3004725 RA-4410RC Remote Annunciator 3006400 BB-RA-44R Surface Mount Back Box for RA-4410RC (Red) 3006401 I Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-121 l• Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG #5401250 - REV D PAGE 1 OF 2 8/20 I (E)POTTER PFC-4410RC The Symbol of Protection RELEASING CONTROL PANEL Architects/Engineers Specifications I I I The control panel for the extinguishing agent releasing system shall be a microprocessor based control capable of protecting multiple hazards in one control panel. It shall be Underwriters Laboratories Inc. listed under Standard 864 Tenth Edition and Underwriters Laboratories of Canada for Local Control Units for Releasing Service. The control shall also be approved by Factory Mutual Research Corporation and be compliant with the requirements of NFPA-72 (Local: A, M, SS service types; DAC and NC signaling type) and NFPA12, NFPA12A, NFPA-13, NFPA-15, NFPA-16, NFPA-17, NFPA-17A, NFPA-750, and NFPA-2001. The control shall be housed in an 18 gauge steel cabinet that has a hinged, removable door with a key lock. The finish shall be baked enamel and available in red with contrasting trim and logo. An optional matching bezel should be available for semi-flush mounting. The cabinet shall have adequate space to house 18 AH standby batteries capable of operating the system for at least 90 hours. The control shall include a fully supervised integral power supply/battery charger capable of providing 200rnA to the auxiliary power circuit. It shall also be capable of providing 2.5 Amps to all releasing and notification appliance circuits combined. All initiating, output and auxiliary power circuits shall be power limited. The control shall have a 32 character (16 characters, 2 lines) backlit LCD display and a 34 LED supplemental display. All diagnostic and alarm event information shall be viewable in text form on this display. A field programmable custom banner message with the current date and time shall be displayed when no current alarm or diagnostic information exists. All operational features of the control panel shall be field programmable using menu driven selections on the alpha-numeric display and on board controls. No special programmer will be required and jumpers or switches to configure operational features shall not be permitted. Alarm and trouble indications shall resound when required. The control panel shall be equipped with 24 programs built into the panel memory, 15 for water based extinguishing and 9 for agent extinguishing. In addition, the panel shall have the ability to add custom programs. All programming functions shall be password protected. The control shall have four fully supervised Class B (Style B) initiating circuits capable of supporting the operation of 25 compatible 2-wire smoke detectors on each circuit. The individual circuits shall be selectable through the programming sequence to operate in one of the following modes: Conventional, Waterfiow, Linear Heat Detection (up to 700 ohms per zone), Manual Release, Low Air Alarm, Supervisory, Tamper, Low Air or High Air. Optional Class A modules, CA2Z, may be added for Class A operation. The panel shall have a Low Air Zone that creates a supervisory condition and can be mapped to a release output. The control shall have two fully supervised Class B (Style B) supervisory circuits. These circuits shall be selectable through the programming sequence to operate in one of the following modes: Supervisory, Tamper, Low Air or High Air. The control shall have one fully supervised class B (style B) Abort circuit with 4 different operating modes, ULI, IRI, and NYC, and 30 second. The control shall have four fully supervised Class B (Style Y) output circuits. These circuits shall be selectable through the programming sequence to operate as one of the following: Alarm Notification Appliance, Supervisory Notification Appliance, Trouble Notification Appliance or Releasing. The optional CAM module may be added to convert the outputs to Class A. The panel shall have an RS-485 output and auxiliary power outputs for connection and supervision of up to 4 remote annunciators or an ARM-44 Relay Module and 3 annunciators. The releasing circuits shall be supervised for short circuit conditions and shall be programmable for cross zoning operation when required. The discharge timer for these releasing circuits shall be programmable for times of 7, 8, 9, 10, 20 minutes or continuous. All initiating and output circuits shall be capable of being individually disabled or enabled. In addition, when in the agent extinguishing mode there shall be a pre-discharge timer adjustable from 0-60 seconds from an alarm zone or 0-30 seconds from a manual release zone. The control shall have a test mode that will automatically disable all releasing circuits. The test mode shall operate in such a manner as to automatically reset the initiating circuit and indicating circuits after detecting each alarm condition initiated by the test. All testing shall be recorded in the 40 event history buffer. The test mode will automatically terminate after twenty minutes of inactivity. The control shall have four integral relay contacts rated 3 Amps at 30 VDC for connection to external auxiliary equipment. One relay shall operate when an alarm condition occurs, another when a trouble signal occurs, the third when a supervisory condition occurs, and the fourth during a waterfiow condition. UL and ULC Listed, FM Approved, NYMEA Accepted, CSFM Approved, CE Marked and RoHS Compliant. I [1 I 1 I H I I I Li I I I PRINTED IN USA MFG #5401250 - REV D PAGE 2 OF 2 I 8/20 LIFE CHARACTERISTICS IN STAND-BY USE 100 80 60 40 20 II I I Ambient Temperature 20°C (68F) I Float Charging Voltage 2.25 - 2.30 V/Cell 0L 0 1 2 3 4 5 Years CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have difficulty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc. PS-1270 12V6$AH@1O-hr Rechargeable Sealed Lead Acid Battery PS - General Purpose Series SHELF LIFE & STORAGE 1 ciraikigis not ). necessary unles 100%o1capac4 is required. ctagingeture use is necessar~ full capacity. I, I \ •-.. - - - - - - - I 40°C 30°C 20°C 1i iii I, - (104°F). _(86°F) - -(68°F) I Standing Period (Months) CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c - 2.45v/c (14.1 - 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to float charge to avoid overcharging. I I aFloat" or "Stand-By" Service: Apply constant voltage charge of 2.25v/c - 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both I I Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual! Power Sonic Charger specifications. I APPLICATIONS General purpose • Medical Emergency lighting • Fire and security ICORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation I 7550 Panasonic Way, San Diego, California 92154 1: +1(619)661 2020 F: +1(619) 661 3650 100 I POWER-SONIC EUROPE LIMITED (EMEA - EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS1 1 8VQ T: +44(0)1268 560686 F: +44(0)1268560902 Fl: Quick disconnect tabs, Ft Quick disconnect tabs, 0A 8-r x 0.037 - Mate with 0.250' x 0,032' - Mate with AMP. INC. FASTON 187 series AMR INC FASTON 250° series -'- 14-2.5 OR k-a Torque- Not Applicable Torque - Not Applicable L 5.95(151) W: 2.56(65) it 3.70(94) W HT: 3.86(98) 0 I Tolerances aie+I- 0.04 in. (4/- 1mm) and +1- 0.08 In. ________________________ 1 (1- 5mm) for height ....L. dknenslons. AR data subject to change without notice., MODEL HI 1ZVoIt 7.4A,.p.l,. MOP r' CORPORATE HEADQUARTERS (USA no 1111111111091114 (XWIiING tWA} Power$ciIc Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1(619)661 2020 F +1(619)661 3650 POWER-SONIC EUROPE liMITED MO- WROK MIDDU MSI MU ARUCA3 3 Buckingham Square, Hurricane Way, Wickiord, Essex SS11 8YQ T: +44(0)1268560686 F: +44(0)1268 560902 I I I PS1270 IZV 6.5 40 @ lObr. Rechargeable Sealed Lead Acid Battery PS General Purpose Series FEATURES Absorbent Glass Mat (AGM) technology for I superior performance Valve regulated, maintenance free spill proof construction Power/volume ratio yielding excellent energy density Rugged vibration and impact resistant ABS case and cover I Gas recombination technology 5 year design life APPROVALS Approved for transport by air. D.O.T., I.A.T.A, F.A.A. and C.A.B. certified U.L. recognized , 1S09001:2015 — Quality rnanagàmertt systems I Nmlnal Voltage l2 volts (6cells) — Nominal Capacity 20-hr. (350rnAto1050voIts) 700A1-1 10-hr (650cnA to 10.50 volts) 6,50 AH S-hr, (1.2AF10.20volts) 6.00AH 1-hr. (45l)9.00volts) 450A1-1 Approximate Weight - 4.80 lbs. (2.18 kg) Internal Resistance (approx.) 23.0 milllohms Max S*IOet.Dwatlon Distharge Qarent (10 Sec.) 70.0 amperes Shelf We (%-of nominal capacity at 68°F (20'C) I Month 97% 3 Month 91% 6 Month 83% Operating Temperature Range Charge 5°F (-15°C) to 122°F (50°C) Discharge -4°F (-20°C) to 140°F (60°C) Case ABS Plastic Power SemcCg.re , -, PSC-121000PC I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. I CATEGORY: LISTEE: DESIGN: RATING: I INSTALLATION: MARKING: I APPROVAL: I I I I I I I 7272-0410:0504 Page 1 of I 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268 Contact: Tony Lujan (714) 670-3248 Fax (714) 522-2268 Email: tlujanhochiki.com Hochiki Models SOC-24V, SOC-24VW, and SOC-24VN photoelectric smoke detector. Detectors are for use with separately listed base models of the same manufacturer. Refer to listee's data sheet for detailed product description and operational considerations. 24 Vdc In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating and UL label. Listed as photoelectric smoke detectors for use with separately listed fire alarm control units and base models of the same manufacturer. 07-17-17 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator I Fire Engineering Division I I it HOCJ41KI I SOC-24V, CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR APPLICATIONS I I STANDARD FEATURES bl Computer-designed non-directional smoke chamber 3600 view of detector status LED Low profile, 2" high (with base) 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/Transient protection Low standby current, 59pA at 24VDC One built-in power/sensitivity supervision/alarm LED Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2 & 7, Inspection, Testing and Maintenance. Magnetic Test Feature SPECIFICATIONS The SOC-24V is a reliable, high quality Photoelectric Smoke Detector. It can be used in all open areas where Photoelectric Smoke Detectors are required, including in-duct applications. The computer-designed smoke chamber makes the SOC-24V well suited for detecting smoldering fires as well as fast- flaming fires. NS-4 Series, NS-6 Series, HSC-4R or HSC-R Style bases may be used with the SOC-24V. OPERATION The SOC-24V photoelectric smoke detector utilizes one bicol- ored LED for indication of status. In a normal standby condi- tion the LED flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sen- sitivity window the LED will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the status LED will latch on Red. The detector utilizes an infrared LED light source and silicon photodiode receiving element in the smoke chamber. In a normal standby condition, the receiving element receives no light from the pulsing LED light source. In the event of a fire, smoke enters the detector smoke chamber and light is reflect- ed from the smoke particles to the receiving element. The light received is converted into an electronic signal. Fire Judgement signals are processed and compared to a reference level, and when five consecutive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The status LED light continuously during the alarm period. I I I I I Light Source GaAlAs Infrared Emitting Diode Nominal Rated Voltage 12 or 24 VDC Working Voltage 8 - 35.0 VDC Maximum Voltage 42 VDC Supervisory Current 59pA @ 24 VDC Surge Current 160pA max. Q 24VDC Alarm Current 150mA max. @24 VDC Air Velocity Range 0-4000 fpm Maximum Humidity 95% RH Non-Condensing Ambient Temperature 32°F to 120°F (0°C to 49°C) Color & Case Material Bone PC/ABS Blend Sensitivity Test Feature Automatic Sensitivity window verification test SENSOR SPACING Smoke sensor spacing shall be in compliance with NFPA 72. For smooth ceilings and in the absence of specific perfor- mance-based design criteria, the distance between smoke sensors shall not exceed a nominal spacing of 30 ft. (9.1 m) all points on the ceiling shall have a sensor within a distance equal to or less than 0.7 times the nominal 30 ft. (9.1m) spacing. Sensors shall be located within a distance of one-half the nominal spacing, measured at right angles from all walls or partitions extending upward to within the top 15 percent of the ceiling height. For additional instructions see NFPA 72. I I I I I Sensitivity Range 1.36%/FT - 3.12%/FT Mounting Refer to NS Conventional Detector Base Data Sheet I SIGNAUNC California State j Fire Marshal I LISTED APPROVED 7272-0410:0504 51383 3061300 Specifications subject to change without notice. Continued on back. Hochiki America Corporation Find latest revision at www.hochiki.com 7051 Village Drive, Suite 100, Buena Park, CA 90621-2268 Phone: 714-522-2246 Fax: 714-522-2268 Technical Support: 800-845-6692 or technicalsupport@hochiki.com eo Air. it kwmbW h thD 78A F0212 06/2019 I 1 I I I I I 1 I I I I I I Ii HOCJ41KI SOC-24V CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR ENGINEERING SPECIFICATIONS The contractor shall furnish and install where indicated on the plans, Hochiki America Model SOC-24V photoelectric smoke detec- tors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel. The base shall permit direct interchange with Hochiki America SOC-24V photoelectric smoke detector. The base shall be appropriate twist- lock base NS-4 Series, NS-6 Series, HSC-4R, or HSC-R. In the event of partial or complete retrofit, the SOC-24V maybe used in conjunction with, or as a replacement for, Hochiki America detectors (SLR-24V, SLR-24VN, SLK-24 and the SLR-24H) on most HSB and HSC base applications. The smoke detector shall have one flashing status LED for visual supervision. When the detector is in standby condition the LED will flash Green. When the detector is outside the UL listed sensitivity window the LED will flash Red. When the detector is actuated, the flashing LED will latch on Red. The detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being measured. The sensitivity of the detector shall be monitored automatically and continu- ously to verify that it is operating within the listed sensitivity range. To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated. JV SOC-24V SENSITIVITY TEST FEATURE . . '.. . The SOC-24V Photoelectric Smoke Detector has a built-in automatic sensitivity test feature.............' 1. In normal condition, the status LED flashes green. .. .. ' ... 2.. When the sensitivity drifts outside of its sensitivity limits, the status LED flashes red. , In the alarm state, the status LED is red continuously. When the sensitivity drifts outside of its sensitivity limits and the status LED flashes red, the device needs to be cleaned or returned to the factory for cleaning or calibration.. Refer to HA Technical Bulletin HA-97 for cleaning information. . .2—WIRE OPERATION cow - 5= AnnU,ioIsUo, 20 mA 0 24 could result LceVV Ag 4—WIRE OPERATION E. . Hochiki America Corporation SOC-24V CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR Specifications subject to change without notice. us," hiD OF UWI 5, - UOIO1WWChW W54 SSIDWVS 0150 555100 - 50e, WITH THI -r HUFflhl ARt CHIVE IC COLOR :e must be current limited tel - Loidmum. Not lio*iiUsg CUIVECt moge to the detector or .maditlon. V 2—WIRE RELAY OPERATION I I it H0CJm41K1 CONVENTIONAL DETECTOR BASES MC AND NS4 SERIES BASE I I I ) cy NS Series Bases Alarm Current ID N$-224 OR NS4-224 43mA (70mA @ 33.OV MAX) HB-5 NS6-220 OR NS4-220 93mA (136mA @ 33.OV MAX) 1-113-3 NS6-221 OR NS4-221 46mA (77mA @ 33.OV MAX) HB-4 NS6-100" OR NS4100* 150mA @ 15.0-33.OV MAX HB-55 * Requires external current limiting to 150mA maximum HSC-(X)R RELAY BASE & HSC- 4114 WIRE BASE 2 Wire Auxiliary Relay Bases Alarm Current ID HSC-224R 43mA (58mA © 30.OV MAX) HB-73 HSC-220R 88mA (98mA @ 265V MAX) HB-72 HSC-221R 49rnA (62mA @ 30.OV MAX) HB-71 4 WIre Base Alarm Current ID HSC-4R 43mA (58mA @ 30.OV MAX) N/A HSC-(X) L LATCHING LED BASE 2 Wire Latching Alarm Current ID HSC-224L 35-42mA @ 24V (54mA MAX) HB-62 HSC-220L 67-8OmA @ 24V HB-64 (88.5mA © 26.5V DC MAX) The N56 and NS4 series bases are designed specifically for use with Hochiki's conventional models: Photoelectric smoke detectors: SOC-24V, SOC-24VN, SLR-24V, SLV-24, SLV-24N, SLV-24V, SLR-835, SLR-24H Photoelectric with heat smoke detector: SLR-835H Fixed temperature/rate-of-rise heat detector. DCD-1 35/190 The NS6 base is an electronics free 6" base featuring a plastic tam- per-lock lug. Each base is equipped with a resistor. Please refer to the chart (left) for additional specifications. The NS4 base is a 4" version of the NS6 base. Models HSC-224R, HSC-220R and the HSC-221R are designed specifically for use with the Hochiki conventional models SOC-24V, SOC-24VN, SLR-24H, SLR-24V, SLV-24, SLV-24N, SLV-24V, SLR- 835, SLR-835H, DCD-135/190. The HSC-(X)R series is a 6" base with two sets of Form "C" relay contacts. Models HSC-224R, HSC-220R and the HSC-221R are also approved for use with Hochiki's previous conventional model DFE 135/190. The HSC-4R is designed specifically for 24 volt 4 wire applications using Hochiki conventional models SOC-24V, SOC-24VN, SLR-24H, SLR-24V, SLV-24, SLV-24N, SLV-24V, SLR-835, SLR-835H or DCD-135/190. The 6" diameter base is current limited. Relay contact place a direct short circuit across the loop when the detector is actu- ated. Model HSC-4R is also approved for use with Hochiki's previous conventional model DFE 135/190. The HSC-L base series are designed specifically for use with the Hochiki fixed temperature heat detectors (models DFE-135/190). The HSC-L series is a 6" base featuring a current limiting resistor, latching annunciator output and a latching circuit so the alarm LED will remain lit until the control panel has been reset. Bases are available in bone or white to match the detector. Bone (off- white) is the standard color for detectors and bases for most applica- tions. BASE BOX MOUNTING 3" OCT 4" OCT 4" SQR 1`S4-13ASE YES NO NO NS6-13ASE NO YES YES HSC-BASE NO YES YES PRODUCT LISTINGS SIGNALING California State CSIUS APPROVED Fire Marshal I LISTED 7300-0410-0132 1 S1383 1D5AI,A4 I I I 1 I I I I I I I I I I I We tty to keep our prçiducf information up-to .dafe and accurat. However, we HSC-221 L 37-45rnA t 24V (57mA MAX) HB-63 cannot cover all specifications or anticipate all requirements. i-or additional information contact your local distributor or Hochiki America Corporation. Hochiki America Corporation Find latest revision at www.hochiki.com 7051 Village Drive, Suite 100, Buena Park, CA 90621-2268 Phone: 714-522-2246 Fax: 714-522-2268 Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0014 Rev.1 08/2017 INITIA C UL LI PG SW! 2 2-WIRE OPERATION it HOCMIKI CONVENTIONAL DETECTOR BASES NS4 AND NS6 SERIES BASE 2-WIRE OPERATION UL LISTED CONTROL PANEL PANEL POWER SUPPLY NEGATIVE HSC-(X)R RELAY 4 (1 NS4 SERIES NS6 SERIES Annunciation device must be current limited to 20 mA @ 24VDC Maximum. Not limiting current could result in damage to the detector on cause a 00.510011 condition. LISTED EN8EQCNE NOTE: - WIRING TERMINALS FOR THE NS4 AND NS6 ARE IDENTICAL - BASES ARE AVAILABLE IN BONE OR WHITE TO MATCH THE DETECTOR. BONE (OFF WHITE) IS THE STANDARD COLOR FOR DETECTORS AND BASES FOR MOST APPLICATIONS. - BASES WITH THE IN" SUFFIX ARE WHITE IN COLOR 2-WIRE OPERATION HSC-411 FOUR WIRE BASE 4-WIRE OPERATION LISTED EN8EQ&NE I - oaRv1_ PIGTAIL AUXILLIARY CONTACTS TWO FORM C' RELAYS SHOWN WITH POWER OFF. Relay Contact Ratings: 2A @ 30VDC IA @ 120VAC UL LI CON1 P1 LISTED EN8EQCLNE o r ______ I H1H2 - TERMINAL 0C2 I PIGTAIL AUXILLIARY IovtLr I CONTACTS ONE OPUR __________ FORM C" LISTED Relay Contact Ratings: 2A t 3DVDC END OF LINE 1A @ I20VAC RELAY HA-EOLR-24 UL LISTED CONTROL PANEL LISTED END OF LINE DEVICE PANEL I LI POWER L2 PIGTAIL LEAD SUPPLY NEGATIVE HSC-(X) L SERIES NS6 SERIES We try to keep our product information up-to-date and accurate. However we cannot cover all specifications or anticipate all requirements. For additional information contact your local distributor or Hochiki America Corporation. Hochiki America Corporation Conventional Detectors Bases Specifications subject to change without notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeyweIl.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-132, LENS-R2, LENS-AC2, LENS-BC2, LENS-GG2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W Ceilinglrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, I Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I I I I I [H I I I I I I I I I I I - Listing No. 7135-1653:0503 - Page 2of2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational consideraticns. RATING: 12 VDC regulated and 24 VDC/FWR - INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 1• . - - - .- - - 4. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. - - Fire Engineering Division -. - f ---.- .--: -• III. F 1. a A2 ~W_' I I f SYSTEM $ SEN5OR I Indoor Selectable- Output Horns, I Strobes, and Horn Strobes for I Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features 1 I I Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-In design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Reid-selectable candela settings on wall units -- 15, 30,75,95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device Installation Electrically compatible with legacy SpectrAlert and SpectrAlest Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting Only Horns listed for wall or ceiling use Agency UsUngs $GNAUWB USTED AOVEO 6I2 rMl4ic*ød oew H251.14 S4llI AWniOd I5* The System Sensor L$erlos offers the most vusatite and easy-to-use line of horns, strobes, and horn strobes in the industry with Icw5- current draws and modarr aesthetics. Wth while anJ red plastic tcuslnga, standard and compact devices, ani plain, Fl RE, and FUE-O-printed devices, System Sensor L-Series car meet virtually any application requirement The L-Series line of wall-mount horns, strobes, anc horn srobe; include s variety of features that increase their application versatility while slrnplifying installation. All devices feature plug-In designs with minimal Intrusion into the back box, making installations fast and fooIpoof while virtually eliminating costly and time-consuming Wound failts. To further simplify installation and pro;-'W devices from construction damage the L-Series utilizes a uriversal mounting plate for all models with an onboard shorting prhg, so installers can :est wiring continuity before the device is insallod, Installers -an also easily adapt devices to a suit a wine range of appllcslon requirements using held-selectable c.acdea settings, automatic selection of 12- or 24-volt oceralion, and a rotary switch for horn tones with two volume salecti-ns. I I I I I H I I I AVOMM06 292111-'Pa 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shat mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used formounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuitr Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6'L x 4.7"W x 1.91 "D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26' Lx 3.46W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7'W x 1.25"D (143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45W x 1.25' D (133 mm Lx 88 mm W x 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12V nominal only for 15 cd and 30 cd. P1 AVDS865-05 • 2/22/2018 • Page 2 LI I P1 I I I P1 I I I " P1 LI I I [I L-Series Dimensions 1.91" k— 846 " - 48. 5mm -_ ._. 3.46" I ____________ I-. t25 —3.57"------. t55" I 1.25" 88 mm I 32 mm (9.1 cm) I (3.9CM) 32 mm Hi.. I 133.9 mm 5.27" 0100040 a 5.38" (13.7cm) 133.9mm A0545-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Watt Surface Mount Back Box SBBGRL, SBBGWL U 5.67" (((4 cm) I I I I I I I I h— 479" —4 (11.94 cm) 1.91. (4.85 cm) 1.25" (3.18 mm) Strobe, Horn Strobe A0550.00 32 mm A0549-00 Horn A0554-01 Walt Surface Mount Back Box SBBRLISBBWL L-Series Ordering Information Model Pll1[.1i Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White V2HL 2-Wire, Uompact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horns* HRL* Horn, Red HWL* Horn, White HGRL* Compact Horn, Red HGWL* Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no 'FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. *Hornonly models are listed for wall or ceiling use. I I I I I I I I I SYSTEM SENSOR I 3825 Ohio Avenue • St. Charles, IL 60174 ©2016 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change wchout notice. \hat systemsensorcom for current product information, including the latest version of this data sheet www.systemsensor.com AVDS865.05 • 2/22/2016 UL Current Draw Data Candela _I 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal high 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 1 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.lK Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3. 11 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Ccded High 85 90 90 10* 3: KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAG voltage is held constant, the horn output remains constantly on. AVDS865-05 • 2/22/2018 • Page 3 I I I I I Page 1 of I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7300-1004:0101 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America lnc.25 Corporate Dr., Auburn Hills, Ml 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MR101/c/R *MR10155E/C *MR101..SsE/CIR MR-104/C, *MR104/c/R, *MR..104..SSE/C *MR..I04..SSE/c/R MR-201/C, MR201/C/*R, *MR.201..sSEIc *MR201SSE/C/R, MR-204/C, MR-204/C/-R, *MR204..SSE/c *MR204SSE/C/R PAM-I, PAM-2, PAM-3, PAM-4, PAM-SD, RlC-I, RIC-2, RlC-3, RIC-4, MR-RIC-301 /*C, *MRRlc..30I /CIR, MRRlC305*/C, * MR-RIC-305/C/R, MRRlC401*/C, *MR..RIC..401/C/R MRRIC405*/C and *MR..RIC..405IC/R relay modules. *Models MR-ITM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: 1. Formerly Air Products and Controls, Inc. I I I I I *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILL.O,, M.E., F.P.E. I Fire Engineering Division I I I I I I I I Li I I GAl®! RELAYS MR-100, 200 SERIES MULTI-VOLTAGE CONTROL RELAYS J• BY SPACE AGE ELECTRONICS PRODUCT DESCRIPTION The MR Series Multi-Voltage Control Relays offer SPDT or DPDT 10 Amp resistive contacts which maybe operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, I 2OVAC or 230VAC by wiring to appropriate input terminals. Each relay position contains a red LED which indicates the relay coil is energized. Relays may be "snapped apart" from a standard 4 module assembly and used independently. These Devices are Ideal for applications where local contacts are required for system status, - remote contacts for control of electrical loads and general purpose switching.They are suitable for use with HVAC,Temperature Control, Fire Alarm, Security, Energy Management -. and Lighting Control Systems. FEATURES + Relays may be energized from a voltage source of 18 to 35VDC orVAC, I20VAC or 230VAC Each relay position contains a red LED, which illuminates when the coil is energized.This provides a time saving device when checking an installed C US LISTED . D r vi IC versions mounted in enclosures /C/R versions with red covers for NYC and other uses CSFM LISTED 0 IT versions come complete with track mounting hardware which facilitates MEA ACCEPTED installation in standard cabinets . UL recognized relays rated at 10,000,000 mechanical operations COMPONENT + UL listed as Control Unit Accessory UUKL Smoke Control I I I I I I system - no metering is required Single, dual or triple relay modules may be "snapped apart" from standard 4-position master + DC control inputs are polarized For continuous duty use at 24VAC, 24VDC or I 2OVAC (NOTE: Not intended for continuous duty use @ 230VAC) o Available in dust resistant pnrin'z,urpc with LED viewing runrt(c WIRING SPDT CONTACTS (TYPICAL FOR ONE 7A ZSVDC, ISA (NO: 116HP, NC: Ii8HP) @ I20VAC. 7A @ 230VAC MODULE POSITION) /1TT\ U III • NC C NO• SSU-MR-10 RELAY ENERGIZED—.. I LED F1 INPUT CONTROL • 0 18124 115 230 VOLTAGES i I I I 24(18.35)VDCI8mA —.+ (— (+) 24(I8-35)VAC @18mA —4 &C. .0 ) 120VAC18mA N H 230VAC@18mA .—+_L2 —4_ DPOT CONTACTS 7A @ 28VDC, bA (NO: 116HP, NC: II8HP) @ 120 VAC, 7A @ 230vAC i ilrTNl II i 8INC CNONC C NO• SSU-MR-201 iI[]11I I RELAY I ENERGIZED—.4 I I LED 10 I I I INPUT i00Di CONTROL 0 18124 115 2300I VOLTAGES I I I I 24(I8.35)VDC481iA 24(I8-35)VAC @40rnA —4 &C. &C I20VAC@40mA —+ N H 230VAC@40mA —4 L2 LI I H I H I I I PRODUCT SPECIFICATIONS UL MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE FILE NUMBER: POSITIONS PER POSITION H X W X D H X W X 0 MATERIAL S3403 73-92-E 7300-1004 3.25" (82mm) SPDT 2.125" (54mm) UOXX2 :106 MR-101/T 1.50" (38mm) Grey SSU MR-1 01/C 1 SPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 14 3.125" (79mm) 2.50"(63mm) Plastic UOXX2 4V0UUKL*Vol. _______ ______ :101 1 SPDT FRdUOXX7SSU 22 MR-IOIiCIR tic 3.25" (82mm) 4 SPDT 8.50" (215mm) UOXX2 :106 MR--1041T 1.50" (38mm) Plated ssu- MR-104!C 4 SPDT . 5.125" (130mm) l8ga uoxx 9.50" (241mm) 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 14 :101 SSU Red MR-1 04/dR 4 SPOT 18ga UUKL* CRS 3.25" (82mm) ssu- DPDT 2.125" (54mm) UOXX2 :106 MR-201/T 1.50" (38mm) Grey MR-201/C DPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 16 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 UOXX7 UUKL* _______ :101 ssu- 1 DPDT Red ABS-94V0 ______ Vol. 22 MR-20IICIR Plastic 3.25" (82mm) SSU 4 DPDT 8.5" (215mm) UOXX2 :106 MR-2041T 1.50" (38mm) Plated ssU- MR-204/C 4 DPDT 5.125" (130mm) l8ga UOXX 9.50" (241mm) . 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 16 :101 ssu- Red MR-2041CIR 4 DPDT 18ga UUKL* CRS COIL VOLTAGE: MR-100: 24(18-35)VDC. 24(18-35)VAC. 120VAC. 230VAC MR-200: 24(18-35)VDC, 24VAC, I20VAC, 230VAC (Pull in voltage: 75% of nominal max. @ 25°C; Drop out voltage: 25% of nominal mm. @ 25°C) POLARIZED: DC input only ENERGIZED LED INDICATOR: One per module position CURRENT REQUIREMENT: Per module position: MR-1 00 Series = 18mA I MR-200 Series = 40mA CONTACT RATINGS: 7A © 28VDC I 10A (NO:1/6HP, NC:1/8HP) @I2OVAC I 7A @ 230VAC CONTACT CONSTRUCTION: Dry Form "C" ENVIRONMENTAL: 32°F to 120°F (0°C to 49°C) @85% RH (@32°F), Non-condensing, Non-freezing WIRING: Solid or stranded; #14 to #22 AWG terminals IT VERSIONS: 3.5" wide, low profile plastic snap track provided with mounting screws IC VERSIONS: Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom "UOxXConfroI Unit Accessories, System; 2=Component; 7=Certified for Canada *UUKL (UL864) = Smoke Control System Equipment System - I I I I H H H I H I H I I I I I I SPACE AGE E LECTRONICS www.lsae.com I office 978.212.13121 fax 508.485.4740 © Copyright 2018 Space Age Electronics, Inc. I This document is subject to change without notice I LT1 0278 I ED0313 I Rev. C I I