Loading...
HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; ; FPC2020-0190; Permit11:2 1JITli1 E1I)1FTI (Lrcity of Cailsbad iHJ Print Date: 01/28/2021 Permit No: FPC2020-0190 Job Address: 1950 CAMINO VIDA ROBLE, CARLSBAD, CA 92008-6599 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120931200 Track #: Applied: 11/05/2020 Valuation: $0.00 Lot #: Issued: 12/03/2020 Occupancy Group: Project #: Finaled Close Out: 01/28/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: ALPHATEC -FIRE SPRINKLER TI (BRANCHLINES ONLY) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System > 100 heads $654.00 FIRE Reinspection (per inspection) $193.00 FIRE Reinspection (per inspection)$193.00 Total Fees: $1,517.00 Total Payments To Date: $1,517.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov A j lit" PIRC PROTECTION F-FC2-0 /~-o - Ovlo Fire Protection Contractor - License #989280 FIRE SUPRESSION HYDRAULIC CALCULATIONS ALPHATEC BRANCHLINES 1950 CAMINO VIDA ROBLE CARLSBAD, CA. 92008 CONTRACT NO. 20726 1341 DitI1L,UIIOn Way, Suuta 14- Vigta, CA 92081 760-295-3881 - phn - 760295-3437— fax www.titanfpinc.com Page No. 219 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Aiphatec Spine SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 1950 Camino Vida Roble CITY: Carlsbad PHONE: ( 760) 295-3436 (Titan Fire Protection) FAX NUMBER: (760) 295-3437 Largest Building (ft.2): 111,214 Sprinkled? Yes Construction Type: Ill-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Camino Vida Roble west of Owens Avenue TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 132 PSI Hydrant Number (if applicable):H60422 Elevation of test: 246 Feet Main Size: 16 INCH Pressure Zone 550 Feet Date/Time of Test - Pitot Tube Reading: Psi Corresponding Flow: GPM; Total Flow: 6,550 GPM Residual Pressure 109 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Based on the square footage of the building and construction type, a fire flow of 7,000 gpm is required. However, this exceeds the City's maximum velocity criteria. The fire flow that meets both velocity and pressure criteria is 6,550 gpm. No reduction for sprinklers has been included in this analysis. The maximum fire flow available onsite at Hydrant H61472 that meets the City's criteria is 2,580 gpm. This is due to a segment of 8-inch main on both the connections to Camino Vida Roble and Kellogg Avenue. The residual pressure during this event is 120 psi. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: Title/Org: P41VIana Date: 03/19/2020 I pRIVATE RD It It 8. 8 v0 v r I 4 I I 4\ \ IFire Hydrant H61472 ) I I \ Max Flow = 2,580 gpm C%b 1/ I 4 / Project Site • 44f I I I 4 4 6- 4 4 6- I • 4 /Cb Legend Fire Flow Test 0 w—Hydrant Location H60422 Pipe N ZONE —550+ p.' 4 4 #219 Alphatec Spine (1950 Camino Vida Roble) - Fire Flow Analysis EXISTING FEATURES Sizes: U 21/2" U 3" U 8" U 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U G - with groove end OS&Y gate valves U L - less shut-off valves U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U - with cu ft/min meter APPLICATION Designed for installation on potable water fire protection lines to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE ASSE® Listed 1048 (Horizontal and Vertical Flow-Up) AVWVA Compliant C510 (Horizontal & Vertical Flow-Up) UL® Classified (Horizontal) C-UL® Classified (Horizontal) CSA® Certified (Horizontal and Vertical Flow-Up) FM®Approved (Horizontal and Vertical Flow-Up) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow-Up, except 10" vertical) MATERIALS Main valve body Cast Iron ASTM A126 Class B Access covers Cast Iron ASTM Al 26 Class B Coatings FDAApproved Epoxy finish Internals Stainless Steel, 300 Series Cast Bronze ASTM B 584 Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers DelrinTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U Gate valve tamper switch (OSY-40) B A DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL B E E WITHOUT WITH OS&Y SIZE A WITHOUT C D OS&Y GATE OS&Y F GATE GATE GATE VALVES GATE VALVES VALVES VALVES OPEN VALVES in. lmm I in. lmm in. lmm in. lmm in. Imm in. I mm in. I mm in. 'mm lbs.l kg lbs.I kg .2 1/2 65 371/81 943 22 I 559 4 1102 10 I 254 163/81 416 137/81352 4 1102 101 I 45.9 211 95.8 3 I 80 381/8 I 968 1 22 I 559 4 1102 10 18 7/81 479 155/8 397 4 1102 101 I 45.9 231 1104.9 8 1200 711/81 1807 48 I 1219 7 1/2 191 16 W54 37 959 291/4 743 7 1/21 191 847 1384.5 1323 1600.6 10 250 841/8 2137 58 I 1473 9 22918 453/41 1162 353/8 899 9 1229 114101 640.1 2228 11011.5 e 104 200 400 600 FLOW RATES (GPM) MODEL 950DA 8" & 10" (STANDARD & METRIC) FLOW RATES (Ifs) 63.1 126.2 189.3 252.4 ;IL FLOW CHARACTERISTICS MODEL 950DA 21/2" & 3" (STANDARD & METRIC) FLOW RATES (us) 12.6 25.2 37.9 IL 0 1000 2000 3000 FLOW RATES (GPM) Rated Flow (Established by approval agencies) 50.5 104 69 35 co Cn 4000 - - TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8 780 1169 1559 2339 10" 1229 1843 2458 3687 PROTECTIVE ENCLOSURE 12" MIN. 30" MAX. SUPPORT DIRECTION OF FLOW MAIN INLET CD OUTDOOR INSTALLATION VERTICAL INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048, and supplied with full port OS&Y gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM A126 Class B), the seat ring and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a WILKINS Model 950DA. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) 9 Website: http://www.zurn.com - Fire Protection by Computer Design Titan Fire Protection Inc 1341 Distribution Way, Ste 14 Vista, CA 92081 760.295.3436 Job Name : 20726 - Atec - Branchlines_FP design Building : FP3 Location : 1950 CAMINO VIDA ROBLE CARLSBAD, CA 92008 System : Area I Contract : 20726 Data File : 20726- Atec - Branchlines Area 1-PEAK.WXF AREA 1 PEAK Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Titan Fire Protection Inc 20726 - Atec - Branchlines_FP design HYDRAULIC CALCULATIONS for Project name: ATEC BRANCHUNES Location: 1950 CAMINO VlDA ROBLE CARLSBAD, CA 92008 Drawing no: FP3 Date: 11-2-20 Design Remote area number: Area 1 Remote area location: WAREHOUSE Occupancy classification: HIGH HAZARD - GROUP A PLASTICS Density: - - Gpm/SqFt Area of application: 12 SPRINK - SqFt Coverage per sprinkler: 100 - SqFt Type of sprinklers calculated: K25.2 @15 PSI No. of sprinklers calculated: 12 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1,433.32-GPM Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 3-19-20 Location: SEE PLAN Source: CITY OF CARLSBAD Name of contractor. TITAN FIRE PROTECTION Address: 1341 DISTRIBUTION WAY, SUITE 14 VISTA, CA 92081 Phone number: 760-295-3436 Name of designer: E. MARTINEZ Authority having jurisdiction: CITY OF CARLSBAD Notes: (Include peaking information or gridded systems here.) Page Date @ 80.39-Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Titan Fire Protection Inc Page 2 20726 - Atec - Branchlines_FP design Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 11.694 C2 - Residual Pressure: 95.8 D2 - System Flow : 1183.32 C2 - Residual Flow : 6550 D2 - System Pressure : 80.392 Hose ( Demand) : 250 D3 - System Demand :1433.32 Safety Margin : 37.024 150 140 130 Cl p120 R 110 - - - E 100 - __ 590 -- D2 s 80 U 70 R6° E5° 40 30 20 • - ....l I I 10 I I I ______________________________ 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Titan Fire Protection Inc Page 3 20726 - Atec - Branchlines_FP design Date Fitting Legend Abbrev. Name 1/2 % 1 114 11/2 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA I39O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zit Wilkins 950DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Titan Fire Protection Inc Page 4 20726 - Atec - Branchlines_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 2 27.0 25.2 15.0 na 97.6 0.1 100 15.0 45 27.0 25.2 15.45 na 99.04 0.1 100 15.0 48 27.0 17.33 na 50 27.0 35.94 na 99 24.0 40.84 na 100 24.0 40.85 na 101 24.0 40.89 na TR1 24.0 56.64 na BR1 0.5 67.15 na BF1 -3.0 69.72 na BF2 -3.0 79.31 na UG1 -3.0 80.19 na TEST 0.0 80.39 na 250.0 102 27.0 25.2 15.01 na 97.65 0.1 100 15.0 103 27.0 25.2 15.75 na 100.01 0.1 100 15.0 104 27.0 18.18 na 105 27.0 30.7 na 106 24.0 36.64 na 107 24.0 36.66 na 108 24.0 36.71 na 109 24.0 36.83 na 110 24.0 36.95 na 111 24.0 37.05 na 112 24.0 37.14 na 113 24.0 37.22 na 114 24.0 37.28 na 115 24.0 37.33 na 116 24.0 37.37 na 117 24.0 37.41 na 118 24.0 37.43 na 119 24.0 37.45 na 120 24.0 37.47 na 122 24.0 37.47 na 123 24.0 37.48 na 124 24.0 37.48 na 130 24.0 39.74 na 131 24.0 39.75 na 132 24.0 39.75 na 133 24.0 39.75 na 135 24.0 39.76 na 136 24.0 39.78 na 137 24.0 39.8 na 138 24.0 39.82 na 139 24.0 39.86 na 140 24.0 39.9 na 141 24.0 39.95 na 142 24.0 40.01 na 143 24.0 40.09 na 144 24.0 40.17 na 145 24.0 40.28 na 146 24.0 40.76 na 147 24.0 40.88 na 148 27.0 30.71 na 149 27.0 18.18 na 150 27.0 25.2 15.76 na 100.03 0.1 100 15.0 151 27.0 25.2 15.02 na 97.66 0.1 100 15.0 152 27.0 25.2 15.01 na 97.62 0.1 100 15.0 153 27.0 25.2 15.45 na 99.06 0.1 100 15.0 154 27.0 17.33 na 155 27.0 35.96 na 156 27.0 30.76 na 157 27.0 18.21 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard Titan Fire Protection Inc Page 5 20726 - Atec - Branchlines_FP design Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 158 27.0 25.2 15.78 na 100.1 0.1 100 15.0 159 27.0 25.2 15.04 na 97.73 0.1 100 15.0 160 27.0 25.2 15.03 na 97.68 0.1 100 15.0 161 27.0 25.2 15.47 na 99.13 0.1 100 15.0 162 27.0 17.35 na 163 27.0 35.99 na 164 27.0 35.85 na 165 27.0 39.15 na 166 27.0 35.92 na 167 27.0 38.71 na 168 27.0 36.0 na 169 27.0 38.63 na 170 27.0 36.08 na 171 27.0 38.55 na 172 27.0 36.14 na 173 27.0 38.49 na 174 27.0 36.19 na 175 27.0 38.44 na 176 27.0 36.24 na 177 27.0 38.39 na 178 27.0 36.27 na 179 27.0 38.36 na 180 27.0 36.3 na 181 27.0 38.33 na 182 27.0 36.32 na 183 27.0 38.31 na 184 27.0 36.34 na 185 27.0 38.29 na 186 27.0 36.35 na 187 27.0 38.28 na 190 27.0 36.36 na 191 27.0 38.27 na 192 27.0 36.36 na 193 27.0 38.27 na 194 27.0 36.36 na 195 27.0 38.27 na 125 24.0 37.48 na 196 27.0 36.36 na 197 27.0 38.26 na The maximum velocity is 18.52 and it occurs in the pipe between nodes 108 and 156 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 6 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt P1/Ft Eqv. Ln. Total Pf Pn 2 84.53 2.157 0.0 8.000 15.000 K Factor = 25.20 to 120.0 0.0 0.0 0.0 45 84.53 0.0560 0.0 8.000 0.448 Vel = 7.42 45 99.04 2.157 0.0 8.000 15.448 K Factor = 25.20 to 120.0 0.0 0.0 0.0 48 183.57 0.2349 0.0 8.000 1.879 Vel = 16.12 48 0.0 2.157 1 12.307 66.960 17.327 to 120.0 0.0 12.307 0.0 50 183.57 0.2349 0.0 79.267 18.618 Vel = 16.12 50 0.0 2.157 T 12.307 3.000 35.945 to 120.0 0.0 12.307 1.299 99 183.57 0.2349 0.0 15.307 3.595 Vel = 16.12 99 0.0 6.357 0.0 10.000 40.839 to 120.0 0.0 0.0 0.0 100 183.57 0.0013 0.0 10.000 0.013 Vel = 1.86 100 183.60 6.357 0.0 9.500 40.852 to 120.0 0.0 0.0 0.0 101 367.17 0.0043 0.0 9.500 0.041 Vel = 3.71 101 816.15 6.357 1 37.72 321.800 40.893 to 120.0 3E 52.808 90.528 0.0 TR1 1183.32 0.0382 0.0 412.328 15.751 Vel = 11.96 TRI 0.0 8.249 B 21.297 24.500 56.644 to 150.0 0.0 21.297 10.178 BR1 1183.32 0.0071 0.0 45.797 0.325 Vel = 7.10 BR1 0.0 7.68 E 22.555 82.540 67.147 to 150.0 0.0 22.555 1.516 BF1 1183.32 0.0101 0.0 105.095 1.058 Vel = 8.20 BFI 0.0 8.27 4E 113.872 12.000 69.721 to 140.0 Zit 0.0 113.872 8.581 * * Fixed Loss = 8.581 BF2 1183.32 0.0080 0.0 125.872 1.004 Vel = 7.07 BF2 0.0 7.68 1 43.857 44.040 79.306 to 150.0 0.0 43.857 0.0 UG1 1183.32 0.0101 0.0 87.897 0.884 Vel = 8.20 UGI 0.0 9.42 F 12.305 273.420 80.190 to 150.0 2T 111.863 129.761 -1.299 TEST 1183.32 0.0037 G 5.593 403.181 1.501 Vel = 5.45 250.00 Qa = 250.00 1433.32 80.392 K Factor = 159.86 2 13.07 2.157 0.0 8.000 15.000 to 120.0 0.0 0.0 0.0 102 13.07 0.0018 0.0 8.000 0.014 Vel = 1.15 102 97.65 2.157 0.0 8.000 15.014 K Factor= 25.20 to 120.0 0.0 0.0 0.0 103 110.72 0.0922 0.0 8.000 0.738 Vel = 9.72 103 100.01 2.157 0.0 8.000 15.752 K Factor = 25.20 to 120.0 0.0 0.0 0.0 104 210.73 0.3031 0.0 8.000 2.425 Vel = 18.50 104 0.0 2.157 1 12.307 29.000 18.177 to 120.0 0.0 12.307 0.0 105 210.73 0.3032 0.0 41.307 12.523 Vel = 18.50 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 7 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Cl' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 105 0.0 2.157 1 12.307 3.000 30.700 to 120.0 0.0 12.307 1.299 106 210.73 0.3032 0.0 15.307 4.641 Vel = 18.50 106 0.0 6.357 0.0 10.000 36.640 to 120.0 0.0 0.0 0.0 107 210.73 0.0016 0.0 10.000 0.016 Vel = 2.13 107 210.79 6.357 0.0 10.000 36.656 to 120.0 0.0 0.0 0.0 108 421.52 0.0057 0.0 10.000 0.057 Vel = 4.26 108 210.99 6.357 0.0 10.000 36.713 to 120.0 0.0 0.0 0.0 109 632.51 0.0120 0.0 10.000 0.120 Vel = 6.39 109 -49.21 6.357 0.0 11.500 36.833 to 120.0 0.0 0.0 0.0 110 583.3 0.0103 0.0 11.500 0.118 Vel = 5.90 110 -44.89 6.357 0.0 11.500 36.951 to 120.0 0.0 0.0 0.0 111 538.41 0.0090 0.0 11.500 0.103 Vel = 5.44 111 -43.37 6.357 0.0 11.500 37.054 to 120.0 0.0 0.0 0.0 112 495.04 0.0076 0.0 11.500 0.087 Vel = 5.00 112 -42.04 6.357 0.0 11.500 37.141 to 120.0 0.0 0.0 0.0 113 453.0 0.0065 0.0 11.500 0.075 Vel = 4.58 113 -40.87 6.357 0.0 11.500 37.216 to 120.0 0.0 0.0 0.0 114 412.13 0.0054 0.0 11.500 0.062 Vel = 4.17 114 -39.88 6.357 0.0 11.500 37.278 to 120.0 0.0 0.0 0.0 115 372.25 0.0045 0.0 11.500 0.052 Vel = 3.76 115 -39.04 6.357 0.0 11.500 37.330 to 120.0 0.0 0.0 0.0 116 333.21 0.0037 0.0 11.500 0.042 Vel= 3.37 116 -38.34 6.357 0.0 11.500 37.372 to 120.0 0.0 0.0 0.0 117 294.87 0.0030 0.0 11.500 0.034 Vel = 2.98 117 -37.77 6.357 0.0 11.500 37.406 to 120.0 0.0 0.0 0.0 118 257.1 0.0023 0.0 11.500 0.026 Vel = 2.60 118 -37.34 6.357 0.0 11.500 37.432 to 120.0 0.0 0.0 0.0 119 219.76 0.0017 0.0 11.500 0.019 Vel= 2.22 119 -36.99 6.357 0.0 11.500 37.451 to 120.0 0.0 0.0 0.0 120 182.77 0.0012 0.0 11.500 0.014 Vel = 1.85 120 -36.76 6.357 0.0 11.500 37.465 to 120.0 0.0 0.0 0.0 122 146.01 0.0008 0.0 11.500 0.009 Vel = 1.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 8 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 122 -36.60 6.357 0.0 12.000 37.474 to 120.0 0.0 0.0 0.0 123 109.41 0.0005 0.0 12.000 0.006 Vel = 1.11 123 -36.51 6.357 0.0 12.000 37.480 to 120.0 0.0 0.0 0.0 124 72.9 0.0002 0.0 12.000 0.002 Vel = 0.74 124 -36.46 6.357 0.0 12.000 37.482 to 120.0 0.0 0.0 0.0 125 36.44 0.0001 0.0 12.000 0.001 Vel = 0.37 0.0 36.44 37.483 K Factor = 5.95 130 36.44 6.357 0.0 12.000 39.745 to 120.0 0.0 0.0 0.0 131 36.44 0.0001 0.0 12.000 0.001 Vel = 0.37 131 36.46 6.357 0.0 12.000 39.746 to 120.0 0.0 0.0 0.0 132 72.9 0.0002 0.0 12.000 0.002 Vel = 0.74 132 36.51 6.357 0.0 12.000 39.748 to 120.0 0.0 0.0 0.0 133 109.41 0.0005 0.0 12.000 0.006 VeI= 1.11 133 36.60 6.357 0.0 11.500 39.754 to 120.0 0.0 0.0 0.0 135 146.01 0.0008 0.0 11.500 0.009 Vel = 1.48 135 36.76 6.357 0.0 11.500 39.763 to 120.0 0.0 0.0 0.0 136 182.77 0.0012 0.0 11.500 0.014 Vel = 1.85 136 36.99 6.357 0.0 11.500 39.777 to 120.0 0.0 0.0 0.0 137 219.76 0.0017 0.0 11.500 0.019 Vel = 2.22 137 37.34 6.357 0.0 11.500 39.796 to 120.0 0.0 0.0 0.0 138 257.1 0.0023 0.0 11.500 0.026 Vel = 2.60 138 37.77 6.357 0.0 11.500 39.822 to 120.0 0.0 0.0 0.0 139 294.87 0.0030 0.0 11.500 0.034 Vel = 2.98 139 38.34 6.357 0.0 11.500 39.856 to 120.0 0.0 0.0 0.0 140 333.21 0.0037 0.0 11.500 0.042 Vel = 3.37 140 39.04 6.357 0.0 11.500 39.898 to 120.0 0.0 0.0 0.0 141 372.25 0.0045 0.0 11.500 0.052 Vel = 3.76 141 39.88 6.357 0.0 11.500 39.950 to 120.0 0.0 0.0 0.0 142 412.13 0.0054 0.0 11.500 0.062 Vel = 4.17 142 40.87 6.357 0.0 11.500 40.012 to 120.0 0.0 0.0 0.0 143 453.0 0.0064 0.0 11.500 0.074 Vel = 4.58 143 42.04 6.357 0.0 11.500 40.086 to 120.0 0.0 0.0 0.0 144 495.04 0.0077 0.0 11.500 0.088 Vel = 5.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 9 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 11cif or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 144 43.37 6.357 0.0 11.500 40.174 to 120.0 0.0 0.0 0.0 145 538.41 0.0089 0.0 11.500 0.102 Vel= 5.44 145 44.89 6.357 2E 35.205 12.000 40.276 to 120.0 0.0 35.205 0.0 146 583.3 0.0103 0.0 47.205 0.488 Vel = 5.90 146 49.21 6.357 0.0 10.000 40.764 to 120.0 0.0 0.0 0.0 147 632.51 0.0120 0.0 10.000 0.120 Vel = 6.39 147 183.65 6.357 0.0 0.500 40.884 to 120.0 0.0 0.0 0.0 101 816.16 0.0180 0.0 0.500 0.009 Vel = 8.25 0.0 816.16 40.893 K Factor = 127.63 107 -210.78 2.157 T 12.307 3.000 36.656 to 120.0 0.0 12.307 -1.299 148 -210.78 -0.3033 0.0 15.307 -4.643 Vel = 18.51 148 0.0 2.157 T 12.307 29.000 30.714 to 120.0 0.0 12.307 0.0 149 -210.78 -0.3033 0.0 41.307 -12.529 Vel = 18.51 149 0.0 2.157 0.0 8.000 18.185 to 120.0 0.0 0.0 0.0 150 -210.78 -0.3034 0.0 8.000 -2.427 Vel = 18.51 150 100.03 2.157 0.0 8.000 15.758 K Factor = 25.20 to 120.0 0.0 0.0 0.0 151 -110.75 -0.0922 0.0 8.000 -0.738 Vel = 9.72 151 97.66 2.157 0.0 8.000 15.020 K Factor = 25.20 to 120.0 0.0 0.0 0.0 152 -13.09 -0.0018 0.0 8.000 -0.014 Vel = 1.15 152 97.62 2.157 0.0 8.000 15.006 K Factor = 25.20 to 120.0 0.0 0.0 0.0 153 84.53 0.0560 0.0 8.000 0.448 Vel = 7.42 153 99.07 2.157 0.0 8.000 15.454 K Factor= 25.20 to 120.0 0.0 0.0 0.0 154 183.6 0.2349 0.0 8.000 1.879 Vel = 16.12 154 0.0 2.157 T 12.307 66.960 17.333 to 120.0 0.0 12.307 0.0 155 183.6 0.2349 0.0 79.267 18.623 Vel = 16.12 155 0.0 2.157 1 12.307 3.000 35.956 to 120.0 0.0 12.307 1.299 100 183.6 0.2350 0.0 15.307 3.597 Vel = 16.12 0.0 183.60 40.852 K Factor = 28.73 108 -210.99 2.157 T 12.307 3.000 36.713 to 120.0 0.0 12.307 -1.299 156 -210.99 -0.3039 0.0 15.307 -4.652 Vel = 18.52 156 0.0 2.157 1 12.307 29.000 30.762 to 120.0 0.0 12.307 0.0 157 -210.99 -0.3039 0.0 41.307 -12.552 Vel = 18.52 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 10 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 157 0.0 2.157 0.0 8.000 18.210 to 120.0 0.0 0.0 0.0 158 -210.99 -0.3039 0.0 8.000 -2.431 Vel = 18.52 158 100.10 2.157 0.0 8.000 15.779 K Factor = 25.20 to 120.0 0.0 0.0 0.0 159 -110.89 -0.0924 0.0 8.000 -0.739 Vel = 9.74 159 97.73 2.157 0.0 8.000 15.040 K Factor = 25.20 to 120.0 0.0 0.0 0.0 160 -13.16 -0.0018 0.0 8.000 -0.014 Vel = 1.16 160 97.68 2.157 0.0 8.000 15.026 K Factor = 25.20 to 120.0 0.0 0.0 0.0 161 84.52 0.0559 0.0 8.000 0.447 Vel = 7.42 161 99.13 2.157 0.0 8.000 15.473 K Factor = 25.20 to 120.0 0.0 0.0 0.0 162 183.65 0.2351 0.0 8.000 1.881 Vel = 16.12 162 0.0 2.157 1 12.307 66.960 17.354 to 120.0 0.0 12.307 0.0 163 183.65 0.2351 0.0 79.267 18.632 Vel = 16.12 163 0.0 2.157 T 12.307 3.000 35.986 to 120.0 0.0 12.307 1.299 147 183.65 0.2351 0.0 15.307 3.599 Vel = 16.12 0.0 183.65 40.884 K Factor = 28.72 109 49.21 2.157 T 12.307 3.000 36.833 to 120.0 0.0 12.307 -1.299 164 49.21 0.0205 0.0 15.307 0.314 Vel = 4.32 164 0.0 2.157 2T 24.613 135.960 35.848 to 120.0 0.0 24.613 0.0 165 49.21 0.0206 0.0 160.573 3.302 Vel = 4.32 165 0.0 2.157 T 12.307 3.000 39.150 to 120.0 0.0 12.307 1.299 146 49.21 0.0206 0.0 15.307 0.315 Vel = 4.32 0.0 49.21 40.764 K Factor = 7.71 110 44.89 2.157 1 12.307 3.000 36.951 to 120.0 0.0 12.307 -1.299 166 44.89 0.0174 0.0 15.307 0.266 Vel = 3.94 166 0.0 2.157 2T 24.613 136.460 35.918 to 120.0 0.0 24.613 0.0 167 44.89 0.0173 0.0 161.073 2.794 Vel = 3.94 167 0.0 2.157 T 12.307 3.000 38.712 to 120.0 0.0 12.307 1.299 145 44.89 0.0173 0.0 15.307 0.265 Vel = 3.94 0.0 44.89 40.276 K Factor = 7.07 111 43.37 2.157 1 12.307 3.000 37.054 to 120.0 0.0 12.307 -1.299 168 43.37 0.0163 0.0 15.307 0.249 Vel = 3.81 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 11 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 168 0.0 2.157 21 24.613 136.460 36.004 to 120.0 0.0 24.613 0.0 169 43.37 0.0163 0.0 161.073 2.622 Vel = 3.81 169 0.0 2.157 1 12.307 3.000 38.626 to 120.0 0.0 12.307 1.299 144 43.37 0.0163 0.0 15.307 0.249 Vel = 3.81 0.0 43.37 40.174 KFactor= 6.84 112 42.04 2.157 1 12.307 3.000 37.141 to 120.0 0.0 12.307 -1.299 170 42.04 0.0154 0.0 15.307 0.235 Vel = 3.69 170 0.0 2.157 21 24.613 136.460 36.077 to 120.0 0.0 24.613 0.0 171 42.04 0.0154 0.0 161.073 2.475 Vel = 3.69 171 0.0 2.157 1 12.307 3.000 38.552 to 120.0 0.0 12.307 1.299 143 42.04 0.0154 0.0 15.307 0.235 Vel = 3.69 0.0 42.04 40.086 K Factor = 6.64 113 40.88 2.157 1 12.307 3.000 37.216 to 120.0 0.0 12.307 -1.299 172 40.88 0.0146 0.0 15.307 0.223 Vel = 3.59 172 0.0 2.157 2T 24.613 136.460 36.140 to 120.0 0.0 24.613 0.0 173 40.88 0.0146 0.0 161.073 2.350 Vel= 3.59 173 0.0 2.157 1 12.307 3.000 38.490 to 120.0 0.0 12.307 1.299 142 40.88 0.0146 0.0 15.307 0.223 Vel = 3.59 0.0 40.88 40.012 K Factor = 6.46 114 39.88 2.157 1 12.307 3.000 37.278 to 120.0 0.0 12.307 -1.299 174 39.88 0.0139 0.0 15.307 0.213 Vel = 3.50 174 0.0 2.157 2T 24.613 136.460 36.192 to 120.0 0.0 24.613 0.0 175 39.88 0.0139 0.0 161.073 2.245 Vel = 3.50 175 0.0 2.157 T 12.307 3.000 38.437 to 120.0 0.0 12.307 1.299 141 39.88 0.0140 0.0 15.307 0.214 Vel = 3.50 0.0 39.88 39.950 K Factor = 6.31 115 39.04 2.157 1 12.307 3.000 37.330 to 120.0 0.0 12.307 -1.299 176 39.04 0.0134 0.0 15.307 0.205 Vel = 3.43 176 0.0 2.157 21 24.613 136.460 36.236 to 120.0 0.0 24.613 0.0 177 39.04 0.0134 0.0 161.073 2.158 Vel = 3.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 12 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 177 0.0 2.157 T 12.307 3.000 38.394 to 120.0 0.0 12.307 1.299 140 39.04 0.0134 0.0 15.307 0.205 Vel = 3.43 0.0 39.04 39.898 K Factor = 6.18 116 38.34 2.157 T 12.307 3.000 37.372 to 120.0 0.0 12.307 -1.299 178 38.34 0.0129 0.0 15.307 0.198 Vel = 3.37 178 0.0 2.157 2T 24.613 136.460 36.271 to 120.0 0.0 24.613 0.0 179 38.34 0.0130 0.0 161.073 2.087 Vel = 3.37 179 0.0 2.157 T 12.307 3.000 38.358 to 120.0 0.0 12.307 1.299 139 38.34 0.0130 0.0 15.307 0.199 Vel = 3.37 0.0 38.34 39.856 K Factor = 6.07 117 37.78 2.157 T 12.307 3.000 37.406 to 120.0 0.0 12.307 -1.299 180 37.78 0.0125 0.0 15.307 0.192 Vel = 3.32 180 0.0 2.157 2T 24.613 136.460 36.299 to 120.0 0.0 24.613 0.0 181 37.78 0.0126 0.0 161.073 2.031 Vel = 3.32 181 0.0 2.157 T 12.307 3.000 38.330 to 120.0 0.0 12.307 1.299 138 37.78 0.0126 0.0 15.307 0.193 Vel = 3.32 0.0 37.78 39.822 K Factor = 5.99 118 37.33 2.157 T 12.307 3.000 37.432 to 120.0 0.0 12.307 -1.299 182 37.33 0.0123 0.0 15.307 0.188 Vel = 3.28 182 0.0 2.157 2T 24.613 136.460 36.321 to 120.0 0.0 24.613 0.0 183 37.33 0.0123 0.0 161.073 1.987 Vel = 3.28 183 0.0 2.157 1 12.307 3.000 38.308 to 120.0 0.0 12.307 1.299 137 37.33 0.0123 0.0 15.307 0.189 Vel = 3.28 0.0 37.33 39.796 K Factor = 5.92 119 37.00 2.157 T 12.307 3.000 37.451 to 120.0 0.0 12.307 -1.299 184 37.0 0.0122 0.0 15.307 0.186 Vel = 3.25 184 0.0 2.157 21 24.613 136.460 36.338 to 120.0 0.0 24.613 0.0 185 37.0 0.0121 0.0 161.073 1.954 Vel = 3.25 185 0.0 2.157 T 12.307 3.000 38.292 to 120.0 0.0 12.307 1.299 136 37.0 0.0122 0.0 15.307 0.186 Vel = 3.25 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 13 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 37.00 39.777 K Factor = 5.87 120 36.76 2.157 T 12.307 3.000 37.465 to 120.0 0.0 12.307 -1.299 186 36.76 0.0120 0.0 15.307 0.183 Vel = 3.23 186 0.0 2.157 2T 24.613 136.460 36.349 to 120.0 0.0 24.613 0.0 187 36.76 0.0120 0.0 161.073 1.931 Vel = 3.23 187 0.0 2.157 T 12.307 3.000 38.280 to 120.0 0.0 12.307 1.299 135 36.76 0.0120 0.0 15.307 0.184 Vel = 3.23 0.0 36.76 39.763 K Factor = 5.83 122 36.60 2.157 T 12.307 3.000 37.474 to 120.0 0.0 12.307 -1.299 190 36.6 0.0119 0.0 15.307 0.182 Vel = 3.21 190 0.0 2.157 21 24.613 136.460 36.357 to 120.0 0.0 24.613 0.0 191 36.6 0.0119 0.0 161.073 1.915 Vel = 3.21 191 0.0 2.157 T 12.307 3.000 38.272 to 120.0 0.0 12.307 1.299 133 36.6 0.0120 0.0 15.307 0.183 Vel = 3.21 0.0 36.60 39.754 K Factor = 5.80 123 36.50 2.157 1 12.307 3.000 37.480 to 120.0 0.0 12.307 -1.299 192 36.5 0.0118 0.0 15.307 0.181 Vel = 3.20 192 0.0 2.157 2T 24.613 136.460 36.362 to 120.0 0.0 24.613 0.0 193 36.5 0.0118 0.0 161.073 1.906 Vel = 3.20 193 0.0 2.157 1 12.307 3.000 38.268 to 120.0 0.0 12.307 1.299 132 36.5 0.0118 0.0 15.307 0.181 Vel = 3.20 0.0 36.50 39.748 K Factor = 5.79 124 36.46 2.157 1 12.307 3.000 37.482 to 120.0 0.0 12.307 -1.299 194 36.46 0.0118 0.0 15.307 0.181 Vel = 3.20 194 0.0 2.157 21 24.613 136.460 36.364 to 120.0 0.0 24.613 0.0 195 36.46 0.0118 0.0 161.073 1.902 Vel = 3.20 195 0.0 2.157 T 12.307 3.000 38.266 to 120.0 0.0 12.307 1.299 131 36.46 0.0118 0.0 15.307 0.181 Vel = 3.20 0.0 36.46 39.746 K Factor = 5.78 125 36.44 2.157 1 12.307 3.000 37.483 to 120.0 0.0 12.307 -1.299 196 36.44 0.0118 0.0 15.307 0.180 Vel = 3.20 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 14 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 196 0.0 2.157 2T 24.613 136.460 36.364 to 120.0 0.0 24.613 0.0 197 36.44 0.0118 0.0 161.073 1.901 Vel = 3.20 197 0.0 2.157 T 12.307 3.000 38.265 to 120.0 0.0 12.307 1.299 130 36.44 0.0118 0.0 15.307 0.181 Vel = 3.20 0.0 36.44 - 39.745 K Factor= 5.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fire Protection by Computer Design Titan Fire Protection Inc 1341 Distribution Way, Ste 14 Vista, CA 92081 760.295.3436 Job Name : 20726 - Atec - Branchlines_FP design Building Location System Contract Data File 20726 - Atec Branchlines Area 1-EAST WXF AREA I EAST OF GRID Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Titan Fire Protection Inc Page 20726 - Atec - Branchlines FP design Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 11.694 C2 - Residual Pressure: 95.8 D2 - System Flow : 1182.93 C2 - Residual Flow : 6550 D2 - System Pressure : 80.637 Hose ( Demand) : 250 D3 - System Demand :1432.93 Safety Margin : 36.780 150 140 130 P 120 R 110 - C2 E 100 - - - s 90 D2 580 u 70 R6° E5° 40 30 20 10 N D1 — I I I I I I 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Titan Fire Protection Inc Page 2 20726 - Atec - Branchlines_FP design Date Fitting Legend Abbrev. Name 1/ % 1 11/4 1'/2 2 21A 3 3Y2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zit Wilkins 950DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Titan Fire Protection Inc Page 3 20726 - Atec - Branchlines_FP design Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 2 27.0 25.2 15.0 na 97.61 0.1 100 15.0 45 27.0 25.2 15.0 na 97.6 0.1 100 15.0 48 27.0 25.2 15.54 na 99.33 0.1 100 15.0 50 27.0 35.87 na 99 24.0 41.09 na 100 24.0 41.1 na 101 24.0 41.15 na TR1 24.0 56.89 na BR1 0.5 67.39 na BF1 -3.0 69.97 na BF2 -3.0 79.55 na UG1 -3.0 80.44 na TEST 0.0 80.64 na 250.0 102 27.0 25.2 15.64 na 99.65 0.1 100 15.0 103 27.0 17.87 na 104 27.0 20.11 na 105 27.0 31.65 na 106 24.0 37.23 na 107 24.0 37.24 na 108 24.0 37.3 na 109 24.0 37.41 na 110 24.0 37.52 na 111 24.0 37.61 na 112 24.0 37.69 na 113 24.0 37.76 na 114 24.0 37.82 na 115 24.0 37.87 na 116 24.0 37.9 na 117 24.0 37.94 na 118 24.0 37.96 na 119 24.0 37.98 na 120 24.0 37.99 na 122 24.0 38.0 na 123 24.0 38.0 na 124 24.0 38.01 na 130 24.0 40.09 na 131 24.0 40.09 na 132 24.0 40.09 na 133 24.0 40.1 na 135 24.0 40.11 na 136 24.0 40.12 na 137 24.0 40.14 na 138 24.0 40.16 na 139 24.0 40.19 na 140 24.0 40.23 na 141 24.0 40.28 na 142 24.0 40.34 na 143 24.0 40.41 na 144 24.0 40.49 na 145 24.0 40.58 na 146 24.0 41.03 na 147 24.0 41.14 na 148 27.0 31.67 na 149 27.0 20.12 na 150 27.0 17.88 na 151 27.0 25.2 15.64 na 99.67 0.1 100 15.0 152 27.0 25.2 15.01 na 97.62 0.1 100 15.0 153 27.0 25.2 15.01 na 97.62 0.1 100 15.0 154 27.0 25.2 15.54 na 99.35 0.1 100 15.0 155 27.0 35.88 na 156 27.0 31.71 na 157 27.0 20.14 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard Titan Fire Protection Inc Page 4 20726 - Atec - Branchlines_FP design Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 158 27.0 . 17.9 na 159 27.0 25.2 15.66 na 99.73 0.1 100 15.0 160 27.0 25.2 15.03 na 97.69 0.1 100 15.0 161 27.0 25.2 15.02 na 97.68 0.1 100 15.0 162 27.0 25.2 15.56 na 99.41 0.1 100 15.0 163 27.0 35.91 na 164 27.0 36.4 na 165 27.0 39.44 na 166 27.0 36.46 na 167 27.0 39.04 na 168 27.0 36.54 na 169 27.0 38.96 na 170 27.0 36.61 na 171 27.0 38.89 na 172 27.0 36.67 na 173 27.0 38.83 na 174 27.0 36.72 na 175 27.0 38.78 na 176 27.0 36.76 na 177 27.0 38.74 na 178 27.0 36.79 na 179 27.0 38.71 na 180 27.0 36.81 na 181 27.0 38.69 na 182 27.0 36.83 na 183 27.0 38.67 na 184 27.0 36.85 na 185 27.0 38.65 na 186 27.0 36.86 na 187 27.0 38.64 na 190 27.0 36.87 na 191 27.0 38.63 na 192 27.0 36.87 na 193 27.0 38.63 na 194 27.0 36.87 na 195 27.0 38.63 na 125 24.0 38.01 na 196 27.0 36.87 na 197 27.0 38.63 na The maximum velocity is 17.72 and it occurs in the pipe between nodes 108 and 156 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 5 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 -4.41 2.157 0.0 8.000 15.002 K Factor = 25.20 to 120.0 0.0 0.0 0.0 45 -4.41 -0.0002 0.0 8.000 -0.002 Vet = 0.39 45 97.60 2.157 0.0 8.000 15.000 K Factor = 25.20 to 120.0 0.0 0.0 0.0 48 93.19 0.0670 0.0 8.000 0.536 Vet = 8.18 48 99.32 2.157 1 12.307 66.960 15.536 K Factor = 25.20 to 120.0 0.0 12.307 0.0 50 192.51 0.2565 0.0 79.267 20.330 Vet = 16.90 50 0.0 2.157 T 12.307 3.000 35.866 to 120.0 0.0 12.307 1.299 99 192.51 0.2565 0.0 15.307 3.927 Vet = 16.90 99 0.0 6.357 0.0 10.000 41.092 to 120.0 0.0 0.0 0.0 100 192.51 0.0013 0.0 10.000 0.013 Vet = 1.95 100 192.55 6.357 0.0 9.500 41.105 to 120.0 0.0 0.0 0.0 101 385.06 0.0047 0.0 9.500 0.045 Vet = 3.89 101 797.87 6.357 T 37.72 321.800 41.150 to 120.0 3E 52.808 90.528 0.0 TRI 1182.93 0.0382 0.0 412.328 15.742 Vet = 11.96 TRI 0.0 8.249 B 21.297 24.500 56.892 to 150.0 0.0 21.297 10.178 BR1 1182.93 0.0071 0.0 45.797 0.325 Vet = 7.10 BR1 0.0 7.68 E 22.555 82.540 67.395 to 150.0 0.0 22.555 1.516 BF1 1182.93 0.0101 0.0 105.095 1.057 Vet = 8.19 BF1 0.0 8.27 4E 113.872 12.000 69.968 to 140.0 Zit 0.0 113.872 8.581 * * Fixed Loss = 8.581 BF2 1182.93 0.0080 0.0 125.872 1.003 Vet = 7.07 BF2 0.0 7.68 T 43.857 44.040 79.552 to 150.0 0.0 43.857 0.0 UGI 1182.93 0.0101 0.0 87.897 0.884 Vet = 8.19 UG1 0.0 9.42 F 12.305 273.420 80.436 to 150.0 2T 111.863 129.761 -1.299 TEST 1182.93 0.0037 G 5.593 403.181 1.500 Vet = 5.45 250.00 Qa = 250.00 1432.93 80.637 K Factor = 159.57 2 102.02 2.157 0.0 8.000 15.002 to 120.0 0.0 0.0 0.0 102 102.02 0.0792 0.0 8.000 0.634 Vet = 8.96 102 99.64 2.157 0.0 8.000 15.636 K Factor = 25.20 to 120.0 0.0 0.0 0.0 103 201.66 0.2795 0.0 8.000 2.236 Vet = 17.71 103 0.0 2.157 0.0 8.000 17.872 to 120.0 0.0 0.0 0.0 104 201.66 0.2795 0.0 8.000 2.236 Vet = 17.71 104 0.0 2.157 T 12.307 29.000 20.108 to 120.0 0.0 12.307 0.0 105 201.66 0.2795 0.0 41.307 11.545 Vet = 17.71 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 6 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 105 0.0 2.157 1 12.307 3.000 31.653 to 120.0 0.0 12.307 1.299 106 201.66 0.2795 0.0 15.307 4.278 Vet = 17.71 106 0.0 6.357 0.0 10.000 37.230 to 120.0 0.0 0.0 0.0 107 201.66 0.0015 0.0 10.000 0.015 Vet = 2.04 107 201.72 6.357 0.0 10.000 37.245 to 120.0 0.0 0.0 0.0 108 403.38 0.0052 0.0 10.000 0.052 Vet = 4.08 108 201.88 6.357 0.0 10.000 37.297 to 120.0 0.0 0.0 0.0 109 605.26 0.0110 0.0 10.000 0.110 Vet = 6.12 109 -47.09 6.357 0.0 11.500 37.407 to 120.0 0.0 0.0 0.0 110 558.17 0.0096 0.0 11.500 0.110 Vel= 5.64 110 42.95 6.357 0.0 11.500 37.517 to 120.0 0.0 0.0 0.0 111 515.22 0.0082 0.0 11.500 0.094 Vet = 5.21 111 -41.50 6.357 0.0 11.500 37.611 to 120.0 0.0 0.0 0.0 112 473.72 0.0070 0.0 11.500 0.081 Vet = 4.79 112 -40.23 6.357 0.0 11.500 37.692 to 120.0 0.0 0.0 0.0 113 433.49 0.0059 0.0 11.500 0.068 Vet = 4.38 113 -39.11 6.357 0.0 11.500 37.760 to 120.0 0.0 0.0 0.0 114 394.38 0.0050 0.0 11.500 0.058 Vet = 3.99 114 -38.17 6.357 0.0 11.500 37.818 to 120.0 0.0 0.0 0.0 115 356.21 0.0042 0.0 11.500 0.048 Vet = 3.60 115 -37.35 6.357 0.0 11.500 37.866 to 120.0 0.0 0.0 0.0 116 318.86 0.0033 0.0 11.500 0.038 Vet = 3.22 116 -36.69 6.357 0.0 11.500 37.904 to 120.0 0.0 0.0 0.0 117 282.17 0.0027 0.0 11.500 0.031 Vet = 2.85 117 -36.15 6.357 0.0 11.500 37.935 to 120.0 0.0 0.0 0.0 118 246.02 0.0021 0.0 11.500 0.024 Vet = 2.49 118 -35.72 6.357 0.0 11.500 37.959 to 120.0 0.0 0.0 0.0 119 210.3 0.0016 0.0 11.500 0.018 Vet = 2.13 119 -35.41 6.357 0.0 11.500 37.977 to 120.0 0.0 0.0 0.0 120 174.89 0.0011 0.0 11.500 0.013 Vet = 1.77 120 -35.17 6.357 0.0 11.500 37.990 to 120.0 0.0 0.0 0.0 122 139.72 0.0007 0.0 11.500 0.008 Vet = 1.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 7 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'IC" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 122 -35.03 6.357 0.0 12.000 37.998 to 120.0 0.0 0.0 0.0 123 104.69 0.0005 0.0 12.000 0.006 Vel = 1.06 123 -34.93 6.357 0.0 12.000 38.004 to 120.0 0.0 0.0 0.0 124 69.76 0.0002 0.0 12.000 0.002 Vel = 0.71 124 -34.89 6.357 0.0 12.000 38.006 to 120.0 0.0 0.0 0.0 125 34.87 0.0001 0.0 12.000 0.001 Vel = 0.35 0.0 34.87 38.007 K Factor = 5.66 130 34.87 6.357 0.0 12.000 40.092 to 120.0 0.0 0.0 0.0 131 34.87 0.0 0.0 12.000 0.0 Vel = 0.35 131 34.89 6.357 0.0 12.000 40.092 to 120.0 0.0 0.0 0.0 132 69.76 0.0002 0.0 12.000 0.003 Vel = 0.71 132 34.93 6.357 0.0 12.000 40.095 to 120.0 0.0 0.0 0.0 133 104.69 0.0004 0.0 12.000 0.005 Vel = 1.06 133 35.03 6.357 0.0 11.500 40.100 to 120.0 0.0 0.0 0.0 135 139.72 0.0007 0.0 11.500 0.008 Vel = 1.41 135 35.17 6.357 0.0 11.500 40.108 to 120.0 0.0 0.0 0.0 136 174.89 0.0011 0.0 11.500 0.013 Vel = 1.77 136 35.41 6.357 0.0 11.500 40.121 to 120.0 0.0 0.0 0.0 137 210.3 0.0016 0.0 11.500 0.018 Vel = 2.13 137 35.72 6.357 0.0 11.500 40.139 to 120.0 0.0 0.0 0.0 138 246.02 0.0021 0.0 11.500 0.024 Vel = 2.49 138 36.15 6.357 0.0 11.500 40.163 to 120.0 0.0 0.0 0.0 139 282.17 0.0027 0.0 11.500 0.031 Vel = 2.85 139 36.69 6.357 0.0 11.500 40.194 to 120.0 0.0 0.0 0.0 140 318.86 0.0034 0.0 11.500 0.039 Vel = 3.22 140 37.35 6.357 0.0 11.500 40.233 to 120.0 0.0 0.0 0.0 141 356.21 0.0041 0.0 11.500 0.047 Vel = 3.60 141 38.17 6.357 0.0 11.500 40.280 to 120.0 0.0 0.0 0.0 142 394.38 0.0050 0.0 11.500 0.058 Vel = 3.99 142 39.11 6.357 0.0 11.500 40.338 to 120.0 0.0 0.0 0.0 143 433.49 0.0059 0.0 11.500 0.068 Vel = 4.38 143 40.23 6.357 0.0 11.500 40.406 to 120.0 0.0 0.0 0.0 144 473.72 0.0070 0.0 11.500 0.081 Vel = 4.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 8 20726 - Atec - Branchtines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 144 41.50 6.357 0.0 11.500 40.487 to 120.0 0.0 0.0 0.0 145 515.22 0.0083 0.0 11.500 0.095 Vet = 5.21 145 42.95 6.357 2E 35.205 12.000 40.582 to 120.0 0.0 35.205 0.0 146 558.17 0.0095 0.0 47.205 0.449 Vet = 5.64 146 47.09 6.357 0.0 10.000 41.031 to 120.0 0.0 0.0 0.0 147 605.26 0.0110 0.0 10.000 0.110 Vet = 6.12 147 192.62 6.357 0.0 0.500 41.141 to 120.0 0.0 0.0 0.0 101 797.88 0.0180 0.0 0.500 0.009 Vet = 8.07 0.0 797.88 41.150 K Factor = 124.38 107 -201.71 2.157 1 12.307 3.000 37.245 to 120.0 0.0 12.307 -1.299 148 -201.71 -0.2797 0.0 15.307 -4.281 Vet = 17.71 148 0.0 2.157 T 12.307 29.000 31.665 to 120.0 0.0 12.307 0.0 149 -201.71 -0.2796 0.0 41.307 -11.549 Vet = 17.71 149 0.0 2.157 0.0 8.000 20.116 to 120.0 0.0 0.0 0.0 150 -201.71 -0.2796 0.0 8.000 -2.237 Vet = 17.71 150 0.0 2.157 0.0 8.000 17.879 to 120.0 0.0 0.0 0.0 151 -201.71 -0.2796 0.0 8.000 -2.237 Vet = 17.71 151 99.67 2.157 0.0 8.000 15.642 K Factor= 25.20 to 120.0 0.0 0.0 0.0 152 -102.04 -0.0792 0.0 8.000 -0.634 Vet = 8.96 152 97.62 2.157 0.0 8.000 15.008 K Factor= 25.20 to 120.0 0.0 0.0 0.0 153 -4.42 -0.0002 0.0 8.000 -0.002 Vet = 0.39 153 97.62 2.157 0.0 8.000 15.006 K Factor = 25.20 to 120.0 0.0 0.0 0.0 154 93.2 0.0670 0.0 8.000 0.536 Vet = 8.18 154 99.34 2.157 T 12.307 66.960 15.542 K Factor = 25.20 to 120.0 0.0 12.307 0.0 155 192.54 0.2566 0.0 79.267 20.336 Vet = 16.90 155 0.0 2.157 T 12.307 3.000 35.878 to 120.0 0.0 12.307 1.299 100 192.54 0.2566 0.0 15.307 3.928 Vet = 16.90 0.0 192.54 41.105 KFactor= 30.03 108 -201.88 2.157 T 12.307 3.000 37.297 to 120.0 0.0 12.307 -1.299 156 -201.88 -0.2801 0.0 15.307 -4.287 Vet = 17.72 156 0.0 2.157 T 12.307 29.000 31.711 to 120.0 0.0 12.307 0.0 157 -201.88 -0.2800 0.0 41.307 -11.568 Vet = 17.72 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 9 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 157 0.0 2.157 0.0 8.000 20.143 to 120.0 0.0 0.0 0.0 158 -201.88 -0.2801 0.0 8.000 -2.241 Vel = 17.72 158 0.0 2.157 0.0 8.000 17.902 to 120.0 0.0 0.0 0.0 159 -201.88 -0.2800 0.0 8.000 -2.240 Vel = 17.72 159 99.73 2.157 0.0 8.000 15.662 K Factor= 25.20 to 120.0 0.0 0.0 0.0 160 -102.15 -0.0795 0.0 8.000 -0.636 Vel = 8.97 160 97.68 2.157 0.0 8.000 15.026 K Factor= 25.20 to 120.0 0.0 0.0 0.0 161 -4.47 -0.0001 0.0 8.000 -0.001 Vel = 0.39 161 97.68 2.157 0.0 8.000 15.025 K Factor = 25.20 to 120.0 0.0 0.0 0.0 162 93.21 0.0670 0.0 8.000 0.536 Vel = 8.18 162 99.41 2.157 1 12.307 66.960 15.561 K Factor = 25.20 to 120.0 0.0 12.307 0.0 163 192.62 0.2567 0.0 79.267 20.351 Vel = 16.91 163 0.0 2.157 T 12.307 3.000 35.912 to 120.0 0.0 12.307 1.299 147 192.62 0.2567 0.0 15.307 3.930 Vel = 16.91 0.0 192.62 41.141 KFactor= 30.03 109 47.09 2.157 T 12.307 3.000 37.407 to 120.0 0.0 12.307 -1.299 164 47.09 0.0189 0.0 15.307 0.290 Vel = 4.13 164 0.0 2.157 2T 24.613 135.960 36.398 to 120.0 0.0 24.613 0.0 165 47.09 0.0190 0.0 160.573 3.043 Vel = 4.13 165 0.0 2.157 1 12.307 3.000 39.441 to 120.0 0.0 12.307 1.299 146 47.09 0.0190 0.0 15.307 0.291 Vel = 4.13 0.0 47.09 41.031 K Factor = 7.35 110 42.95 2.157 T 12.307 3.000 37.517 to 120.0 0.0 12.307 -1.299 166 42.95 0.0159 0.0 15.307 0.244 Vel = 3.77 166 0.0 2.157 2T 24.613 136.460 36.462 to 120.0 0.0 24.613 0.0 167 42.95 0.0160 0.0 161.073 2.576 Vel = 3.77 167 0.0 2.157 T 12.307 3.000 39.038 to 120.0 0.0 12.307 1.299 145 42.95 0.0160 0.0 15.307 0.245 Vel = 3.77 0.0 42.95 40.582 K Factor = 6.74 111 41.50 2.157 T 12.307 3.000 37.611 to 120.0 0.0 12.307 -1.299 168 41.5 0.0150 0.0 15.307 0.229 Vel = 3.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 10 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 168 0.0 2.157 21 24.613 136.460 36.541 to 120.0 0.0 24.613 0.0 169 41.5 0.0150 0.0 161.073 2.417 Vel = 3.64 169 0.0 2.157 1 12.307 3.000 38.958 to 120.0 0.0 12.307 1.299 144 41.5 0.0150 0.0 15.307 0.230 Vel = 3.64 0.0 41.50 40.487 K Factor = 6.52 112 40.23 2.157 T 12.307 3.000 37.692 to 120.0 0.0 12.307 -1.299 170 40.23 0.0141 0.0 15.307 0.216 Vel = 3.53 170 0.0 2.157 2T 24.613 136.460 36.609 to 120.0 0.0 24.613 0.0 171 40.23 0.0142 0.0 161.073 2.281 Vel = 3.53 171 0.0 2.157 1 12.307 3.000 38.890 to 120.0 0.0 12.307 1.299 143 40.23 0.0142 0.0 15.307 0.217 Vel = 3.53 0.0 40.23 40.406 K Factor = 6.33 113 39.12 2.157 T 12.307 3.000 37.760 to 120.0 0.0 12.307 -1.299 172 39.12 0.0135 0.0 15.307 0.206 Vel = 3.43 172 0.0 2.157 21 24.613 136.460 36.667 to 120.0 0.0 24.613 0.0 173 39.12 0.0134 0.0 161.073 2.166 Vel = 3.43 173 0.0 2.157 T 12.307 3.000 38.833 to 120.0 0.0 12.307 1.299 142 39.12 0.0135 0.0 15.307 0.206 Vel = 3.43 0.0 39.12 40.338 K Factor = 6.16 114 38.16 2.157 T 12.307 3.000 37.818 to 120.0 0.0 12.307 -1.299 174 38.16 0.0128 0.0 15.307 0.196 Vel = 3.35 174 0.0 2.157 21 24.613 136.460 36.715 to 120.0 0.0 24.613 0.0 175 38.16 0.0128 0.0 161.073 2.069 Vel = 3.35 175 0.0 2.157 T 12.307 3.000 38.784 to 120.0 0.0 12.307 1.299 141 38.16 0.0129 0.0 15.307 0.197 Vel = 3.35 0.0 38.16 40.280 K Factor= 6.01 115 37.36 2.157 1 12.307 3.000 37.866 to 120.0 0.0 12.307 -1.299 176 37.36 0.0123 0.0 15.307 0.188 Vel = 3.28 176 0.0 2.157 21 24.613 136.460 36.755 to 120.0 0.0 24.613 0.0 177 37.36 0.0123 0.0 161.073 1.989 Vel = 3.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 11 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 177 0.0 2.157 T 12.307 3.000 38.744 to 120.0 0.0 12.307 1.299 140 37.36 0.0124 0.0 15.307 0.190 Vet = 3.28 0.0 37.36 40.233 K Factor = 5.89 116 36.69 2.157 T 12.307 3.000 37.904 to 120.0 0.0 12.307 -1.299 178 36.69 0.0120 0.0 15.307 0.183 Vet = 3.22 178 0.0 2.157 2T 24.613 136.460 36.788 to 120.0 0.0 24.613 0.0 179 36.69 0.0119 0.0 161.073 1.924 Vet = 3.22 179 0.0 2.157 T 12.307 3.000 38.712 to 120.0 0.0 12.307 1.299 139 36.69 0.0120 0.0 15.307 0.183 Vet = 3.22 0.0 36.69 40.194 K Factor = 5.79 117 36.15 2.157 1 12.307 3.000 37.935 to 120.0 0.0 12.307 -1.299 180 36.15 0.0116 0.0 15.307 0.178 Vet= 3.17 180 0.0 2.157 2T 24.613 136.460 36.814 to 120.0 0.0 24.613 0.0 181 36.15 0.0116 0.0 161.073 1.872 Vet= 3.17 181 0.0 2.157 1 12.307 3.000 38.686 to 120.0 0.0 12.307 1.299 138 36.15 0.0116 0.0 15.307 0.178 Vet= 3.17 0.0 36.15 40.163 K Factor = 5.70 118 35.72 2.157 T 12.307 3.000 37.959 to 120.0 0.0 12.307 -1.299 182 35.72 0.0114 0.0 15.307 0.174 Vet= 3.14 182 0.0 2.157 21 24.613 136.460 36.834 to 120.0 0.0 24.613 0.0 183 35.72 0.0114 0.0 161.073 1.832 Vet = 3.14 183 0.0 2.157 T 12.307 3.000 38.666 to 120.0 0.0 12.307 1.299 137 35.72 0.0114 0.0 15.307 0.174 Vet = 3.14 0.0 35.72 40.139 K Factor = 5.64 119 35.40 2.157 1 12.307 3.000 37.977 to 120.0 0.0 12.307 -1.299 184 35.4 0.0112 0.0 15.307 0.171 Vet= 3.11 184 0.0 2.157 21 24.613 136.460 36.849 to 120.0 0.0 24.613 0.0 185 35.4 0.0112 0.0 161.073 1.801 Vet = 3.11 185 0.0 2.157 T 12.307 3.000 38.650 to 120.0 0.0 12.307 1.299 136 35.4 0.0112 0.0 15.307 0.172 Vet = 3.11 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 12 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin 35.40 40.121 K Factor = 5.59 120 35.18 2.157 1 12.307 3.000 37.990 to 120.0 0.0 12.307 -1.299 186 35.18 0.0110 0.0 15.307 0.169 Vel = 3.09 186 0.0 2.157 21 24.613 136.460 36.860 to 120.0 0.0 24.613 0.0 187 35.18 0.0111 0.0 161.073 1.780 Vel = 3.09 187 0.0 2.157 T 12.307 3.000 38.640 to 120.0 0.0 12.307 1.299 135 35.18 0.0110 0.0 15.307 0.169 Vel = 3.09 0.0 35.18 40.108 KFactor= 5.55 122 35.02 2.157 1 12.307 3.000 37.998 to 120.0 0.0 12.307 -1.299 190 35.02 0.0110 0.0 15.307 0.168 Vel = 3.07 190 0.0 2.157 21 24.613 136.460 36.867 to 120.0 0.0 24.613 0.0 191 35.02 0.0110 0.0 161.073 1.766 Vel = 3.07 191 0.0 2.157 T 12.307 3.000 38.633 to 120.0 0.0 12.307 1.299 133 35.02 0.0110 0.0 15.307 0.168 Vel = 3.07 0.0 35.02 40.100 K Factor = 5.53 123 34.93 2.157 T 12.307 3.000 38.004 to 120.0 0.0 12.307 -1.299 192 34.93 0.0108 0.0 15.307 0.166 Vel = 3.07 192 0.0 2.157 2T 24.613 136.460 36.871 to 120.0 0.0 24.613 0.0 193 34.93 0.0109 0.0 161.073 1.757 Vel = 3.07 193 0.0 2.157 1 12.307 3.000 38.628 to 120.0 0.0 12.307 1.299 132 34.93 0.0110 0.0 15.307 0.168 Vel = 3.07 0.0 34.93 40.095 K Factor = 5.52 124 34.89 2.157 T 12.307 3.000 38.006 to 120.0 0.0 12.307 -1.299 194 34.89 0.0108 0.0 15.307 0.166 Vel = 3.06 194 0.0 2.157 21 24.613 136.460 36.873 to 120.0 0.0 24.613 0.0 195 34.89 0.0109 0.0 161.073 1.753 Vel = 3.06 195 0.0 2.157 1 12.307 3.000 38.626 to 120.0 0.0 12.307 1.299 131 34.89 0.0109 0.0 15.307 0.167 Vel = 3.06 0.0 34.89 40.092 K Factor = 5.51 125 34.87 2.157 T 12.307 3.000 38.007 to 120.0 0.0 12.307 -1.299 196 34.87 0.0108 0.0 15.307 0.166 Vel = 3.06 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 13 20726 - Atec - Branchlines_FP design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 196 0.0 2.157 2T 24.613 136.460 36.874 to 120.0 0.0 24.613 0.0 197 34.87 0.0109 0.0 161.073 1.752 Vel = 3.06 197 0.0 2.157 T 12.307 3.000 38.626 to 120.0 0.0 12.307 1.299 130 34.87 0.0109 0.0 15.307 0.167 Vel = 3.06 0.0 34.87 40.092 K Factor = 5.51 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fire Protection by Computer Design Titan Fire Protection Inc 1341 Distribution Way, Ste 14 Vista, CA 92081 760.295.3436 Job Name : 20726 - Atec - Branchlines_FP designWest Building Location System Contract Data File 20726 Atec - Branchlines Area 1 WEST WXF AREA 1 WEST OF GRID Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Titan Fire Protection Inc Page 20726 - Atec - Branchlines_FP designWest Date City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 11.694 C2 - Residual Pressure: 95.8 D2 - System Flow : 1184.06 C2 - Residual Flow : 6550 D2 - System Pressure : 79.899 Hose ( Demand) : 250 D3 - System Demand :1434.06 Safety Margin : 37.516 150 140 130 Cl p120 R 110 - E 100 __ 590 -- D2 580 70 R6° E5° 40 30 20 10 --Dl— • 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N - 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Titan Fire Protection Inc Page 2 20726 - Atec - Branchlines_FP designWest Date Fitting Legend Abbrev. Name h/ ~ 1 11/4 l/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zit Wilkins 950DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Titan Fire Protection Inc Page 3 20726 - Atec - Branchlines_FP designWest Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 2 27.0 25.2 15.37 na 98.78 0.1 100 15.0 45 27.0 17.08 na 48 27.0 18.79 na 50 27.0 35.75 na 99 24.0 40.33 na 100 24.0 40.34 na 101 24.0 40.37 na TRI 24.0 56.14 na BR1 0.5 66.65 na BF1 -3.0 69.22 na BF2 -3.0 78.81 na UGI -3.0 79.7 na TEST 0.0 79.9 na 250.0 102 27.0 25.2 15.0 na 97.6 0.1 100 15.0 103 27.0 25.2 15.04 na 97.72 0.1 100 15.0 104 27.0 25.2 15.89 na 100.44 0.1 100 15.0 105 27.0 29.45 na 106 24.0 35.77 na 107 24.0 35.79 na 108 24.0 35.85 na 109 24.0 35.98 na 110 24.0 36.11 na 111 24.0 36.22 na 112 24.0 36.31 na 113 24.0 36.39 na 114 24.0 36.46 na 115 24.0 36.52 na 116 24.0 36.56 na 117 24.0 36.6 na 118 24.0 36.63 na 119 24.0 36.65 na 120 24.0 36.66 na 122 24.0 36.67 na 123 24.0 36.68 na 124 24.0 36.68 na 130 24.0 39.13 na 131 24.0 39.13 na 132 24.0 39.14 na 133 24.0 39.14 na 135 24.0 39.15 na 136 24.0 39.17 na 137 24.0 39.19 na 138 24.0 39.22 na 139 24.0 39.25 na 140 24.0 39.3 na 141 24.0 39.35 na 142 24.0 39.42 na 143 24.0 39.5 na 144 24.0 39.6 na 145 24.0 39.71 na 146 24.0 40.24 na 147 24.0 40.36 na 148 27.0 29.46 na 149 27.0 25.2 15.89 na 100.46 0.1 100 15.0 150 27.0 25.2 15.04 na 97.74 0.1 100 15.0 151 27.0 25.2 15.01 na 97.62 0.1 100 15.0 152 27.0 25.2 15.37 na 98.8 0.1 100 15.0 153 27.0 17.08 na 154 27.0 18.8 na 155 27.0 35.76 na 156 27.0 29.51 na 157 27.0 25.2 15.92 na 100.54 0.1 100 15.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard Titan Fire Protection Inc Page 4 20726 - Atec - Branchlines_FP designWest Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 158 27.0 25.2 15.06 na 97.81 0.1 100 15.0 159 27.0 25.2 15.03 na 97.69 0.1 100 15.0 160 27.0 25.2 15.39 na 98.87 0.1 100 15.0 161 27.0 17.1 na 162 27.0 18.82 na 163 27.0 35.79 na 164 27.0 35.02 na 165 27.0 38.6 na 166 27.0 35.1 na 167 27.0 38.12 na 168 27.0 35.19 na 169 27.0 38.03 na 170 27.0 35.27 na 171 27.0 37.95 na 172 27.0 35.34 na 173 27.0 37.88 na 174 27.0 35.39 na 175 27.0 37.82 na 176 27.0 35.44 na 177 27.0 37.78 na 178 27.0 35.48 na 179 27.0 37.74 na 180 27.0 35.51 na 181 27.0 37.71 na 182 27.0 35.53 na 183 27.0 37.68 na 184 27.0 35.55 na 185 27.0 37.67 na 186 27.0 35.56 na 187 27.0 37.65 na 190 27.0 35.57 na 191 27.0 37.65 na 192 27.0 35.58 na 193 27.0 37.64 na 194 27.0 35.58 na 195 27.0 37.64 na 125 24.0 36.68 na 196 27.0 35.58 na 197 27.0 37.64 na The maximum velocity is 19.34 and it occurs in the pipe between nodes 108 and 156 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 5 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 174.56 2.157 0.0 8.000 15.366 K Factor = 25.20 to 120.0 0.0 0.0 0.0 45 174.56 0.2140 0.0 8.000 1.712 Vel = 15.33 45 0.0 2.157 0.0 8.000 17.078 to 120.0 0.0 0.0 0.0 48 174.56 0.2139 0.0 8.000 1.711 Vel = 15.33 48 0.0 2.157 T 12.307 66.960 18.789 to 120.0 0.0 12.307 0.0 50 174.56 0.2140 0.0 79.267 16.962 Vel = 15.33 50 0.0 2.157 1 12.307 3.000 35.751 to 120.0 0.0 12.307 1.299 99 174.56 0.2140 0.0 15.307 3.276 Vel = 15.33 99 0.0 6.357 0.0 10.000 40.326 to 120.0 0.0 0.0 0.0 100 174.56 0.0011 0.0 10.000 0.011 Vel = 1.76 100 174.57 6.357 0.0 9.500 40.337 to 120.0 0.0 0.0 0.0 101 349.13 0.0040 0.0 9.500 0.038 Vel = 3.53 101 834.93 6.357 1 37.72 321.800 40.375 to 120.0 3E 52.808 90.528 0.0 TRI 1184.06 0.0382 0.0 412.328 15.769 Vel = 11.97 TRI 0.0 8.249 B 21.297 24.500 56.144 to 150.0 0.0 21.297 10.178 BR1 1184.06 0.0071 0.0 45.797 0.326 Vel = 7.11 BR1 0.0 7.68 E 22.555 82.540 66.648 to 150.0 0.0 22.555 1.516 BFI 1184.06 0.0101 0.0 105.095 1.059 Vel = 8.20 BF1 0.0 8.27 4E 113.872 12.000 69.223 to 140.0 Zit 0.0 113.872 8.582 * * Fixed Loss = 8.582 BF2 1184.06 0.0080 0.0 125.872 1.005 Vel = 7.07 BF2 0.0 7.68 T 43.857 44.040 78.810 to 150.0 0.0 43.857 0.0 UG1 1184.06 0.0101 0.0 87.897 0.885 Vel = 8.20 UGI 0.0 9.42 F 12.305 273.420 79.695 to 150.0 2T 111.863 129.761 -1.299 TEST 1184.06 0.0037 G 5.593 403.181 1.503 Vel = 5.45 250.00 Qa = 250.00 1434.06 79.899 K Factor = 160.43 2 -75.77 2.157 0.0 8.000 15.366 to 120.0 0.0 0.0 0.0 102 -75.77 -0.0458 0.0 8.000 -0.366 Vel = 6.65 102 97.59 2.157 0.0 8.000 15.000 K Factor = 25.20 to 120.0 0.0 0.0 0.0 103 21.82 0.0046 0.0 8.000 0.037 Vel = 1.92 103 97.72 2.157 0.0 8.000 15.037 K Factor = 25.20 to 120.0 0.0 0.0 0.0 104 119.54 0.1061 0.0 8.000 0.849 Vel = 10.50 104 100.44 2.157 T 12.307 29.000 15.886 K Factor = 25.20 to 120.0 0.0 12.307 0.0 105 219.98 0.3283 0.0 41.307 13.560 Vel = 19.31 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 6 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 105 0.0 2.157 T 12.307 3.000 29.446 to 120.0 0.0 12.307 1.299 106 219.98 0.3283 0.0 15.307 5.025 Vel = 19.31 106 0.0 6.357 0.0 10.000 35.770 to 120.0 0.0 0.0 0.0 107 219.98 0.0017 0.0 10.000 0.017 Vel = 2.22 107 220.05 6.357 0.0 10.000 35.787 to 120.0 0.0 0.0 0.0 108 440.03 0.0061 0.0 10.000 0.061 Vel = 4.45 108 220.29 6.357 0.0 10.000 35.848 to 120.0 0.0 0.0 0.0 109 660.32 0.0130 0.0 10.000 0.130 Vel = 6.67 109 -51.37 6.357 0.0 11.500 35.978 to 120.0 0.0 0.0 0.0 110 608.95 0.0112 0.0 11.500 0.129 Vel = 6.16 110 -46.86 6.357 0.0 11.500 36.107 to 120.0 0.0 0.0 0.0 111 562.09 0.0097 0.0 11.500 0.111 Vel = 5.68 111 -45.27 6.357 0.0 11.500 36.218 to 120.0 0.0 0.0 0.0 112 516.82 0.0082 0.0 11.500 0.094 Vel = 5.22 112 -43.89 6.357 0.0 11.500 36.312 to 120.0 0.0 0.0 0.0 113 472.93 0.0070 0.0 11.500 0.081 Vel = 4.78 113 -42.67 6.357 0.0 11.500 36.393 to 120.0 0.0 0.0 0.0 114 430.26 0.0059 0.0 11.500 0.068 Vel = 4.35 114 -41.64 6.357 0.0 11.500 36.461 to 120.0 0.0 0.0 0.0 115 388.62 0.0049 0.0 11.500 0.056 Vel = 3.93 115 40.75 6.357 0.0 11.500 36.517 to 120.0 0.0 0.0 0.0 116 347.87 0.0039 0.0 11.500 0.045 Vel = 3.52 116 -40.03 6.357 0.0 11.500 36.562 to 120.0 0.0 0.0 0.0 117 307.84 0.0032 0.0 11.500 0.037 Vel = 3.11 117 -39.44 6.357 0.0 11.500 36.599 to 120.0 0.0 0.0 0.0 118 268.4 0.0024 0.0 11.500 0.028 Vel = 2.71 118 -38.97 6.357 0.0 11.500 36.627 to 120.0 0.0 0.0 0.0 119 229.43 0.0018 0.0 11.500 0.021 Vel = 2.32 119 -38.63 6.357 0.0 11.500 36.648 to 120.0 0.0 0.0 0.0 120 190.8 0.0013 0.0 11.500 0.015 Vel = 1.93 120 -38.37 6.357 0.0 11.500 36.663 to 120.0 0.0 0.0 0.0 122 152.43 0.0009 0.0 11.500 0.010 Vel = 1.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 7 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "CI' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 122 -38.21 6.357 0.0 12.000 36.673 to 120.0 0.0 0.0 0.0 123 114.22 0.0005 0.0 12.000 0.006 Vel= 1.15 123 -38.11 6.357 0.0 12.000 36.679 to 120.0 0.0 0.0 0.0 124 76.11 0.0002 0.0 12.000 0.003 Vel = 0.77 124 -38.06 6.357 0.0 12.000 36.682 to 120.0 0.0 0.0 0.0 125 38.05 0.0001 0.0 12.000 0.001 Vel = 0.38 0.0 38.05 36.683 K Factor= 6.28 130 38.05 6.357 0.0 12.000 39.132 to 120.0 0.0 0.0 0.0 131 38.05 0.0 0.0 12.000 0.0 Vel = 0.38 131 38.06 6.357 0.0 12.000 39.132 to 120.0 0.0 0.0 0.0 132 76.11 0.0002 0.0 12.000 0.003 Vel = 0.77 132 38.11 6.357 0.0 12.000 39.135 to 120.0 0.0 0.0 0.0 133 114.22 0.0005 0.0 12.000 0.006 Vel= 1.15 133 38.21 6.357 0.0 11.500 39.141 to 120.0 0.0 0.0 0.0 135 152.43 0.0009 0.0 11.500 0.010 Vel = 1.54 135 38.37 6.357 0.0 11.500 39.151 to 120.0 0.0 0.0 0.0 136 190.8 0.0013 0.0 11.500 0.015 Vel = 1.93 136 38.63 6.357 0.0 11.500 39.166 to 120.0 0.0 0.0 0.0 137 229.43 0.0019 0.0 11.500 0.022 Vel = 2.32 137 38.97 6.357 0.0 11.500 39.188 to 120.0 0.0 0.0 0.0 138 268.4 0.0024 0.0 11.500 0.028 Vel = 2.71 138 39.44 6.357 0.0 11.500 39.216 to 120.0 0.0 0.0 0.0 139 307.84 0.0031 0.0 11.500 0.036 Vel = 3.11 139 40.03 6.357 0.0 11.500 39.252 to 120.0 0.0 0.0 0.0 140 347.87 0.0040 0.0 11.500 0.046 Vel = 3.52 140 40.75 6.357 0.0 11.500 39.298 to 120.0 0.0 0.0 0.0 141 388.62 0.0049 0.0 11.500 0.056 Vel = 3.93 141 41.64 6.357 0.0 11.500 39.354 to 120.0 0.0 0.0 0.0 142 430.26 0.0058 0.0 11.500 0.067 Vel = 4.35 142 42.67 6.357 0.0 11.500 39.421 to 120.0 0.0 0.0 0.0 143 472.93 0.0070 0.0 11.500 0.081 Vel = 4.78 143 43.89 6.357 0.0 11.500 39.502 to 120.0 0.0 0.0 0.0 144 516.82 0.0083 0.0 11.500 0.095 Vel = 5.22 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 8 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 144 45.27 6.357 0.0 11.500 39.597 to 120.0 0.0 0.0 0.0 145 562.09 0.0097 0.0 11.500 0.111 Vel = 5.68 145 46.86 6.357 2E 35.205 12.000 39.708 to 120.0 0.0 35.205 0.0 146 608.95 0.0112 0.0 47.205 0.527 Vel = 6.16 146 51.37 6.357 0.0 10.000 40.235 to 120.0 0.0 0.0 0.0 147 660.32 0.0130 0.0 10.000 0.130 Vel = 6.67 147 174.61 6.357 0.0 0.500 40.365 to 120.0 0.0 0.0 0.0 101 834.93 0.0200 0.0 0.500 0.010 Vel = 8.44 0.0 834.93 40.375 K Factor = 131.40 107 -220.05 2.157 T 12.307 3.000 35.787 to 120.0 0.0 12.307 -1.299 148 -220.05 -0.3285 0.0 15.307 -5.028 Vel = 19.32 148 0.0 2.157 T 12.307 29.000 29.460 to 120.0 0.0 12.307 0.0 149 -220.05 -0.3284 0.0 41.307 -13.567 Vel = 19.32 149 100.47 2.157 0.0 8.000 15.893 K Factor = 25.20 to 120.0 0.0 0.0 0.0 150 -119.58 -0.1062 0.0 8.000 -0.850 Vel= 10.50 150 97.73 2.157 0.0 8.000 15.043 K Factor = 25.20 to 120.0 0.0 0.0 0.0 151 -21.85 -0.0046 0.0 8.000 -0.037 Vel = 1.92 151 97.62 2.157 0.0 8.000 15.006 K Factor = 25.20 to 120.0 0.0 0.0 0.0 152 75.77 0.0458 0.0 8.000 0.366 Vel = 6.65 152 98.81 2.157 0.0 8.000 15.372 K Factor = 25.20 to 120.0 0.0 0.0 0.0 153 174.58 0.2140 0.0 8.000 1.712 Vel = 15.33 153 0.0 2.157 0.0 8.000 17.084 to 120.0 0.0 0.0 0.0 154 174.58 0.2140 0.0 8.000 1.712 Vel= 15.33 154 0.0 2.157 T 12.307 66.960 18.796 to 120.0 0.0 12.307 0.0 155 174.58 0.2140 0.0 79.267 16.966 Vel = 15.33 155 0.0 2.157 T 12.307 3.000 35.762 to 120.0 0.0 12.307 1.299 100 174.58 0.2140 0.0 15.307 3.276 Vel = 15.33 0.0 174.58 40.337 K Factor = 27.49 108 -220.29 2.157 T 12.307 3.000 35.848 to 120.0 0.0 12.307 -1.299 156 -220.29 -0.3291 0.0 15.307 -5.038 Vel = 19.34 156 0.0 2.157 T 12.307 29.000 29.511 to 120.0 0.0 12.307 0.0 157 -220.29 -0.3291 0.0 41.307 -13.595 Vel = 19.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 9 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 157 100.53 2.157 0.0 8.000 15.916 K Factor = 25.20 to 120.0 0.0 0.0 0.0 158 -119.76 -0.1065 0.0 8.000 -0.852 Vel = 10.51 158 97.81 2.157 0.0 8.000 15.064 K Factor = 25.20 to 120.0 0.0 0.0 0.0 159 -21.95 -0.0046 0.0 8.000 -0.037 Vel = 1.93 159 97.69 2.157 0.0 8.000 15.027 K Factor = 25.20 to 120.0 0.0 0.0 0.0 160 75.74 0.0456 0.0 8.000 0.365 Vel = 6.65 160 98.86 2.157 0.0 8.000 15.392 K Factor = 25.20 to 120.0 0.0 0.0 0.0 161 174.6 0.2141 0.0 8.000 1.713 Vel = 15.33 161 0.0 2.157 0.0 8.000 17.105 to 120.0 0.0 0.0 0.0 162 174.6 0.2141 0.0 8.000 1.713 Vel = 15.33 162 0.0 2.157 1 12.307 66.960 18.818 to 120.0 0.0 12.307 0.0 163 174.6 0.2141 0.0 79.267 16.970 Vel = 15.33 163 0.0 2.157 1 12.307 3.000 35.788 to 120.0 0.0 12.307 1.299 147 174.6 0.2142 0.0 15.307 3.278 Vel = 15.33 0.0 174.60 40.365 K Factor = 27.48 109 51.37 2.157 1 12.307 3.000 35.978 to 120.0 0.0 12.307 -1.299 164 51.37 0.0223 0.0 15.307 0.341 Vel = 4.51 164 0.0 2.157 2T 24.613 135.960 35.020 to 120.0 0.0 24.613 0.0 165 51.37 0.0223 0.0 160.573 3.575 Vel = 4.51 165 0.0 2.157 1 12.307 3.000 38.595 to 120.0 0.0 12.307 1.299 146 51.37 0.0223 0.0 15.307 0.341 Vel = 4.51 0.0 51.37 40.235 K Factor = 8.10 110 46.86 2.157 T 12.307 3.000 36.107 to 120.0 0.0 12.307 -1.299 166 46.86 0.0187 0.0 15.307 0.287 Vel = 4.11 166 0.0 2.157 21 24.613 136.460 35.095 to 120.0 0.0 24.613 0.0 167 46.86 0.0188 0.0 161.073 3.026 Vel= 4.11 167 0.0 2.157 T 12.307 3.000 38.121 to 120.0 0.0 12.307 1.299 145 46.86 0.0188 0.0 15.307 0.288 Vel = 4.11 0.0 46.86 39.708 K Factor = 7.44 111 45.28 2.157 T 12.307 3.000 36.218 to 120.0 0.0 12.307 -1.299 168 45.28 0.0176 0.0 15.307 0.269 Vel = 3.98 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 10 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 168 0.0 2.157 21 24.613 136.460 35.188 to 120.0 0.0 24.613 0.0 169 45.28 0.0176 0.0 161.073 2.840 Vel = 3.98 169 0.0 2.157 1 12.307 3.000 38.028 to 120.0 0.0 12.307 1.299 144 45.28 0.0176 0.0 15.307 0.270 Vel = 3.98 0.0 45.28 39.597 K Factor = 7.20 112 43.89 2.157 T 12.307 3.000 36.312 to 120.0 0.0 12.307 -1.299 170 43.89 0.0167 0.0 15.307 0.255 Vel = 3.85 170 0.0 2.157 2T 24.613 136.460 35.268 to 120.0 0.0 24.613 0.0 171 43.89 0.0166 0.0 161.073 2.680 Vel = 3.85 171 0.0 2.157 T 12.307 3.000 37.948 to 120.0 0.0 12.307 1.299 143 43.89 0.0167 0.0 15.307 0.255 Vel = 3.85 0.0 43.89 39.502 K Factor = 6.98 113 42.67 2.157 T 12.307 3.000 36.393 to 120.0 0.0 12.307 -1.299 172 42.67 0.0158 0.0 15.307 0.242 Vel = 3.75 172 0.0 2.157 2T 24.613 136.460 35.336 to 120.0 0.0 24.613 0.0 173 42.67 0.0158 0.0 161.073 2.544 Vel = 3.75 173 0.0 2.157 T 12.307 3.000 37.880 to 120.0 0.0 12.307 1.299 142 42.67 0.0158 0.0 15.307 0.242 Vel = 3.75 0.0 42.67 39.421 K Factor = 6.80 114 41.63 2.157 T 12.307 3.000 36.461 to 120.0 0.0 12.307 -1.299 174 41.63 0.0150 0.0 15.307 0.230 Vel = 3.66 174 0.0 2.157 21 24.613 136.460 35.392 to 120.0 0.0 24.613 0.0 175 41.63 0.0151 0.0 161.073 2.431 Vet = 3.66 175 0.0 2.157 T 12.307 3.000 37.823 to 120.0 0.0 12.307 1.299 141 41.63 0.0152 0.0 15.307 0.232 Vel = 3.66 0.0 41.63 39.354 K Factor = 6.64 115 40.75 2.157 T 12.307 3.000 36.517 to 120.0 0.0 12.307 -1.299 176 40.75 0.0144 0.0 15.307 0.221 Vel = 3.58 176 0.0 2.157 2T 24.613 136.460 35.439 to 120.0 0.0 24.613 0.0 177 40.75 0.0145 0.0 161.073 2.337 Vet = 3.58 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 11 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 177 0.0 2.157 1 12.307 3.000 37.776 to 120.0 0.0 12.307 1.299 140 40.75 0.0146 0.0 15.307 0.223 Vel = 3.58 0.0 40.75 39.298 K Factor = 6.50 116 40.03 2.157 1 12.307 3.000 36.562 to 120.0 0.0 12.307 -1.299 178 40.03 0.0140 0.0 15.307 0.215 Vel = 3.51 178 0.0 2.157 21 24.613 136.460 35.478 to 120.0 0.0 24.613 0.0 179 40.03 0.0140 0.0 161.073 2.260 Vel = 3.51 179 0.0 2.157 T 12.307 3.000 37.738 to 120.0 0.0 12.307 1.299 139 40.03 0.0140 0.0 15.307 0.215 Vel = 3.51 0.0 40.03 39.252 K Factor = 6.39 117 39.44 2.157 1 12.307 3.000 36.599 to 120.0 0.0 12.307 -1.299 180 39.44 0.0136 0.0 15.307 0.208 Vel = 3.46 180 0.0 2.157 21 24.613 136.460 35.508 to 120.0 0.0 24.613 0.0 181 39.44 0.0137 0.0 161.073 2.199 Vel= 3.46 181 0.0 2.157 1 12.307 3.000 37.707 to 120.0 0.0 12.307 1.299 138 39.44 0.0137 0.0 15.307 0.210 Vel = 3.46 0.0 39.44 39.216 K Factor = 6.30 118 38.97 2.157 T 12.307 3.000 36.627 to 120.0 0.0 12.307 -1.299 182 38.97 0.0133 0.0 15.307 0.204 Vel = 3.42 182 0.0 2.157 21 24.613 136.460 35.532 to 120.0 0.0 24.613 0.0 183 38.97 0.0134 0.0 161.073 2.152 Vel = 3.42 183 0.0 2.157 T 12.307 3.000 37.684 to 120.0 0.0 12.307 1.299 137 38.97 0.0134 0.0 15.307 0.205 Vel = 3.42 0.0 38.97 39.188 K Factor = 6.23 119 38.63 2.157 T 12.307 3.000 36.648 to 120.0 0.0 12.307 -1.299 184 38.63 0.0131 0.0 15.307 0.201 Vel = 3.39 184 0.0 2.157 2T 24.613 136.460 35.550 to 120.0 0.0 24.613 0.0 185 38.63 0.0131 0.0 161.073 2.116 Vel = 3.39 185 0.0 2.157 T 12.307 3.000 37.666 to 120.0 0.0 12.307 1.299 136 38.63 0.0131 0.0 15.307 0.201 Vel = 3.39 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 12 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. nC' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 38.63 39.166 KFactor= 6.17 120 38.38 2.157 T 12.307 3.000 36.663 to 120.0 0.0 12.307 -1.299 186 38.38 0.0129 0.0 15.307 0.198 Vel = 3.37 186 0.0 2.157 21 24.613 136.460 35.562 to 120.0 0.0 24.613 0.0 187 38.38 0.0130 0.0 161.073 2.091 Vel = 3.37 187 0.0 2.157 1 12.307 3.000 37.653 to 120.0 0.0 12.307 1.299 135 38.38 0.0130 0.0 15.307 0.199 Vel = 3.37 0.0 38.38 39.151 KFactor= 6.13 122 38.21 2.157 T 12.307 3.000 36.673 to 120.0 0.0 12.307 -1.299 190 38.21 0.0129 0.0 15.307 0.197 Vel = 3.35 190 0.0 2.157 21 24.613 136.460 35.571 to 120.0 0.0 24.613 0.0 191 38.21 0.0129 0.0 161.073 2.074 Vel = 3.35 191 0.0 2.157 T 12.307 3.000 37.645 to 120.0 0.0 12.307 1.299 133 38.21 0.0129 0.0 15.307 0.197 Vel = 3.35 0.0 38.21 39.141 KFactor= 6.11 123 38.11 2.157 T 12.307 3.000 36.679 to 120.0 0.0 12.307 -1.299 192 38.11 0.0128 0.0 15.307 0.196 Vel = 3.35 192 0.0 2.157 2T 24.613 136.460 35.576 to 120.0 0.0 24.613 0.0 193 38.11 0.0128 0.0 161.073 2.064 VeI= 3.35 193 0.0 2.157 T 12.307 3.000 37.640 to 120.0 0.0 12.307 1.299 132 38.11 0.0128 0.0 15.307 0.196 Vel = 3.35 0.0 38.11 39.135 K Factor = 6.09 124 38.06 2.157 T 12.307 3.000 36.682 to 120.0 0.0 12.307 -1.299 194 38.06 0.0127 0.0 15.307 0.195 Vel = 3.34 194 0.0 2.157 2T 24.613 136.460 35.578 to 120.0 0.0 24.613 0.0 195 38.06 0.0128 0.0 161.073 2.060 Vel = 3.34 195 0.0 2.157 1 12.307 3.000 37.638 to 120.0 0.0 12.307 1.299 131 38.06 0.0127 0.0 15.307 0.195 Vel = 3.34 0.0 38.06 39.132 K Factor= 6.08 125 38.05 2.157 T 12.307 3.000 36.683 to 120.0 0.0 12.307 -1.299 196 38.05 0.0127 0.0 15.307 0.195 Vel = 3.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Titan Fire Protection Inc Page 13 20726 - Atec - Branchlines_FP designWest Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 196 0.0 2.157 2T 24.613 136.460 35.579 to 120.0 0.0 24.613 0.0 197 38.05 0.0128 0.0 161.073 2.058 Vel = 3.34 197 0.0 2.157 T 12.307 3.000 37.637 to 120.0 0.0 12.307 1.299 130 38.05 0.0128 0.0 15.307 0.196 Vel = 3.34 0.0 38.05 39.132 K Factor = 6.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PERFORMANCE QUALIFICATION TEST RECORD Ve1der Name: Bernatdo Rodrigucz Social Security No.: 8316 Qualification to S: ?°' 301 A.ddess: . 17 St. S eiznaclito.CA 924O Date: 9/22/2016 Date Expires: 9/22/19 I ~:5 JVe1frigiPr,cess: GM&W Manual 0 Semiautomatic Machine Short Circuit (GMW) Yes No 0 MATERIAL SPECIFICATION Group: M21 ASTMAI35 GroupA To: AS'IMA135 GroupA FILLER METAL AWS Specification No.: A5.18 AWS Classification. ER705-6 F No.: F6 Diameter Describe fitter metal (f not covered by AWS specification): ALA TEST WELDMENT Diameter and wall thickness (if pipe) otherwise joint thickness: Diameter. 6" OD Thickness of Test Materiafr .250" GROOVE: Single W" POSITION PIPE 6G Flat 0 Hoñzoninl 0 Overhead 0 VetticalD Upward 0 Downward 0 Backing Nfawaa Yes [] No Consumable lasert Yes [ No S Root Sbie1ding Yes D No 0 Double 0 Single Electrical Characteiistics: Current DC Shielding Gas: Q/Acgpt Percent 75725% Flow Rate.- 50-55 CFH Thickness range this qualifies- J25 Ia .2506" 00 TEST RESULTS LType of Test [NIA Pass Fall Visual Test Results X Bend Test Results X Macro Test Results X Tension Test Results X Radiographic Test Results I X Penetrant Test Results PROCESS QUALLFIED FOR GROOVE Thickness j_1G I 2G I 3G 4G I SG I 6G I 6GR (I) AIin Max Diameter Pipe X X X X I X 1 J25" 1 .250- 1 6" Plate X X JX XJ xf .125" FTTIPT IF J2F 13F 14FJSF [1pe X •X X X •X IPlate XX I X fX IX - —T-be-above namedpon ir qtiaBfiedfo the-v,ieldinSp ss(drt&rt-witbinthe imiof-eienabkàthdingiitateriali-andfifr— metal variables of the AWS Stazd4rdfor We4&g Procedure and Peformaizce ,Qrialificatiotz (4 VS B2. 1) 77e, the wthriined certilj that the statements frr thz:r record are correct and that the zveldr werrpn'pared a,zd testedi,r accordance with the requirements afA'S B2. 1. Azirboriqd Rrprecentath'e of DaartEnineering Co. 1598 North f" St Sam Bemiar&mw, CA 92405 Henry L J*sor CWI 94010401 OCt EXP. v1a813 ~a I tl~. Date PERFORMANCE QUALIFICATION TEST RECORD Name Raul Padilla Id nS WVW~il n ooi) Welder X) Operator ( SSN 0146 Qualifica o£-19 Welding Process GMAW Manual ( ) Semi-Automatic (X) Automatic ( ) Machine Short Circuit (GMAVV) Yes (X) No Material Group M21 ASTM A135 Group A To ASTM A135 Group A Filler Metal F No. 6 AWS Classification ER70S-6 Diameter Position 6G Backing Material No Consumable Insert No Root Shielding No Double ( ) Single (X) Electrical Characteristics: Current DC Polarity N/A Shielding GasCO2/Argon Percent 75/25% Flow 50-55 CFH TEST WELDMENT Thickness of Test Material .250" Diameter 6" GROOVE: Single 'V" PIPE 6G TEST RESULTS Type of Test N/A Pass Fail Visual Test Results X Bend Test Results X Macro Test Results X Tension Test Results X Radiographic Test X Results Penetrant Test Results X PROCESS QUALIFIED FOR: GROOVE 16 2G 1 36 1 46 SG 66 6GR Thickness (T) Min Max Diameter Pipe X X X X X X .125 .250 6" Plate X X X X X .125 .250 Rebar FILLET IF 2F 3F 4F SF Pipe X X X X X Plate X X X X X Rebar The above named person is qualtied for the weithngprocess(és,) used in this test within the limits of essential variables including materials and filler metal variables of/he A WS Standardjr Welthng Procedure and Performance Qualification 4 WS B2. I) Henry L Jackson Date Tested: 04/10/2014 Signed By: / /' cwi 94010401 QCI E.XP 1/1/2015 Job: ALPHATEC - NEW BRANCHLINES #2 11/19/20 Non-Welded & Welded Main Fab Report U All welds are POLs unless noted Shown Left to Right Up Towards Down Away Towards & Away (BOF): Beginning of Flow 24 Quantity: 23 4 Outlets 2 x 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color ORANGE 3/4PD(Up) 3/4 PD 3/4PD(Up) G H HG 2 GOL40 (Down) Between I 0-6 3-6 4-6 8-0 7-6 Run I 0-6 4-0 8-6 16-6 24-0 24A Quantity: 1 5 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) 2 GOL40 (Towards) H hG 2 GOL40 (Down) Between 0-6 3-6 4-6 8-0 4-7 2-11 I I Run 1 0-6 4-0 8-6 16-6 21-1 24-0 25 Quantity: 90 3 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' Blk G-G Color = ORANGE 3/4PD(Up) 3/4PD(Up) 3/4PD(Up) GU HG Between 1 06 80 80 7-6 Run 1 0-6 8-6 16-6 24-0 Page Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #2 ____ 11/19/20 Non-Welded & Welded Main Fab Report C C- U All welds are POLe unless noted Up Towards Down Away Towards & Away (BOF): Beginning of Flow Shown Left to Right 25A Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) 2 GOL40 (Towards) 3/4 PD (Up) 3/4 PD (Up) Gil 17-71 hG Between 0-6 5-9 2-3 8-0 7-6 Run 0-6 6-3 8-6 16-6 24-0 25B Quantity: 1 4 Outlets 2 x 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) 2 GOL40 (Towards) 3/4 PD (Up) 3/4 PD (Up) Gil C HG Between 0-6 7-0 1-0 8-0 7-6 Run 0-6 7-6 8-6 24-0 25C Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) G ________ 1-1/4 GOL40 (Away) Between I 0-6 8-0 8-0 7-01/2 0-51/2 Run 0-6 8-6 16-6 23-61/2 24-0 Page 4 Titan Fire Protection, Inc. FIreList2O.27 Job: ALPHATEC - NEW BRANCHLINES #2 ____ 11/19/20 Non-Welded & Welded Main Fab Report 0 Al welds are POLe unless noted Up Towards Down Away Towards & Away Shown Left to Right (BOF): Beginning of Flow 25D Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color ORANGE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) G H ' ______ 17-71 G _______ 2 GOL40 (Away) Between 1 0-6 8-0 1-71/2 6-41/2 7-6 Run I 0-6 8-6 10-1 1/2 16-6 24-0 25E Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' Blk G-G Color ORANGE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) Gil 17-7 2 GOL40 (Away) Between 1 0-6 8-0 6-6 1-6 7-6 I Run 1 0-6 8-6 15-0 16-6 25F Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color ORANGE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) 2 GOL40 (Towards) Gil 0 IH Between 1 0-6 8-0 8-0 2-5 5-1 Run I 0-6 8-6 16-6 18-11 24-0 Page Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #2 11/19/20 Non-Welded & Welded Main Fab Report LJ Alt welds are POLe unless noted Shown Left to Right Up Towards Dawn Away Towards & Away (BOF): Beginning of Flow 26 Quantity: 23 2 Outlets 2 x 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) 3/4 PD (Up) Gil HG Between 1 0-6 8-0 3-6 Run 0-6 8-6 12-0 26A Quantity: 1 3 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' 81k G-G Color = ORANGE 3/4 PD (Up) 3/4 PD (Up) 2 GOL40 (Towards) Gil 17-7 hG Between 1 0-6 8-0 1-0 2-6 Run I 0-6 8-6 9-6 Pipe End Fitting 12-0 Label Qty Size Length Op Size Description Fin Run Color code = ORANGE Bik Dom Sch 10 A135 GG 24' 27 24 2 1-6 GP 28 Quantity: 1 3 Outlets 2 X 9-5 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) Gil hG 2 GOL40 (Down) 1 PD (Down) Between 1 3-6 4-8 0-9 0-6 Run I 3-6 8-2 8-11 9-5 Page Titan Fire Protection, Inc. FirelJst2.O.27 Job: ALPHATEC - NEW BRANCHLINES #2 ____ 11/19/20 Non-Welded & Welded Main Fab Report C) II -® All welds are POLe unless soled Shown Left to Right Up Towards Down Away Towards & Away (BOF): Beginning of Flow 28A Quantity: 2 3 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) Gil 17-71 2 GOL40 (Down) 1 PD (Down) Between 1 3-6 4-8 3-4 06 Run 3-6 8-2 11-6 12-0 28B Quantity: 1 3 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color ORANGE 3/4 PD (Up) 1-1/2 PD (Towards) 0 hG 2 GOL40 (Down) Between 3-6 4-8 3-4 0-6 Run 3-6 8-2 11-6 12-0 28C Quantity: 20 3 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = ORANGE 3/4 PD (Up) 3/4 PD (Up) Gil 1771 IhG 2 GOL40 (Down) Between 1 3-6 4-8 3-4 0-6 Run I 3-6 8-2 11-6 I Pipe End Fitting 12-0 Label Qty Size Length Op Size Description Fin Run Color code = ORANGE BIk Dom Sch 40 A135 21' RN 48 2 3-0 GP Page Titan Fire Protection, Inc. FlreList2O.27 Job: ALPHATEC - NEW BRANCHLINES #2 11/19/20 Outlet Fab Report Qty PartNo Size Finish Description 1 A0363191024 2 x 1 1/4 BLK GOL DOM 55 A0363191180 2 x 2 BLK GOL DOM 452 A0363190166 2 x 3/4 BLK POL DOM 3 A0363190240 2 x1 BLK POL DOM 1 A0363190463 2 x 1 1/2 BLK POL DOM Page Titan Fire Protection, Inc. End of printout FireList2.O.27 Fab Report Job: ALPHATEC - NEW BRANCHLINES #2 Project Name ALPHATEC - NEW BRANCHLINES #2 Ship To 1950 CAMINO VIDA ROBLE CARLSBAD, CA 92008 US Ship Via Company Name Titan Fire Protection, Inc. Customer Name Scott / Tern Customer Phone number (760) 295-3436 Lister Name & Phone number Larry Linder (951) 674-6959 Shop Location Salesman Code Date Required on site Corona, CA P0 Number * Quote Only Extra Information **BRANCHLINES & R.N.'S ONLY FOR SYSTEM #2 11-19-20 Page 1 Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #2 11/19/20 Branchilne Fab Report Pipe End Fitting Label Qty Size Length Op Size Description Fin Run Color code = ORANGE BIk Dom Sch 40 A135 21' ARMS 1 1-1/2 X 1 -3 IT 1-1/2 x ELL RED Dl B Page 2 Titan Fire Protection, Inc. FireList2O.27 Fab Report Job: ALPHATEC - NEW BRANCHLINES #1 Project Name ALPHATEC - NEW BRANCHLINES #1 Ship To 1950 CAMINO VIDA ROBLE CARLSBAD, CA 92008 us Ship Via Company Name Titan Fire Protection, Inc. Customer Name Scott I Tern Customer Phone number (760) 295-3436 Lister Name & Phone number Larry Linder (951) 674-6959 Shop Location Salesman Code Date Required on site Corona, CA P0 Number * Quote Only Extra Information **BRANCHLINES & R.N.'S ONLY FOR SYSTEM 01 11-17-20 Page 1 Titan Fire Protection, Inc. FireList 20.27 Job: ALPHATEC - NEW BRANCHLINES #1 11/18/20 Branchline Fab Report Pipe End Fitting Label Qty Size Length Op Size Description Fin Run Color code = GREEN Bilk Dom Sch 40 A135 21' ARMS 6 1-1/2 X 1-3 U 1-1/2x1 ELL RED DI B Page Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 11/18/20 Non-Welded & Welded Main Fab Report - All welds are POLo unless soled Up Towards Down Away Towards & Away (BOF): Beginning of Flow Shown Left to Right 13 Quantity: 1 4 Outlets 2 x 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (Up) 2 GOL40 (Up) 1 PD (Up) 1 PD (Up) G H IH Between 0-6 7-8 0-4 8-0 7-6 Run 0-6 8-2 8-6 16-6 24-0 13A Quantity: 2 4 Outlets 2 x 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (Up) 2 GOL4O (Up) 1 PD (Up) 1 PD (Up) G H I Between 0-6 5-01/2 2-11 1/2 8-0 7-6 Run 0-6 5-61/2 8-6 16-6 24-0 13B Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1-1/2 PD (Up) 2 GOL40 (Towards) 1-1/2 PD (Up) 1-1/2 PD (Up) GI C) Between I 0-6 5-01/2 2-111/2 8-0 7-6 Run 0-6 5-61/2 8-6 16-6 24-0 Page Titan Fire Protection, Inc. FireUst2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 ____ 11118/20 Non-Welded & Welded Main Fab Report U All welds are POLo unless noted Shown Left to Right Up Towards Down Away Towards & Away (BOF): Beginning of Flow 13C Quantity: 1 4 Outlets 2 X 17-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (Up) 1 PD (Up) 2 GOL40 (Up) 1 PD (Up) Gil Between I 0-6 8-0 5-01/2 2-111/2 0-6 Run 1 0-6 8-6 13-61/2 16-6 17-0 13D Quantity: 1 4 Outlets 2 x 24-0 Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) Gil HG 2 GOL40 (Down) Between 0-6 5-01/2 2-111/2 8-0 7-6 I I Run I 0-6 5-61/2 8-6 16-6 24-0 14 Quantity: 1 1 Outlet 2 X 1-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (Up) Gil hG Between I 0-6 0-6 Run 0-6 1-0 Page Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 ____ 11/18/20 Non-Welded & Welded Main Fab Report C All welds are POLa unless noted Up Towards Down Away Towards & Away (BOF): Beginning of Flow Shown Left to Right 14A Quantity: 1 3 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' Blk G-G Color GREEN 1 PD (Up) 1 PD (Up) 1 PD (Up) G H 17-1 11 Between 1 7-6 8-0 8-0 0-6 Run 1 7-6 15-6 23-6 24-0 14B Quantity: 2 3 Outlets 2 x 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color GREEN 1 PD (Up) • 1 PD (Up) 1 PD (Up) GU fl Between 1 06 8-0 8-0 7-6 Run 1 0-6 8-6 16-6 24-0 14C Quantity: 1 3 Outlets 2 x 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1-1/2 PD (Up) 1-1/2 PD (Up) 1-1/2 PD (Up) G G Between 1 0-6 8-0 8-0 7-6 Run I 0-6 8-6 16-6 24-0 Page Titan Fire Protection, Inc. FireList2O.27 Job: ALPHATEC - NEW BRANCHLINES #1 11/18/20 Non-Welded & Welded Main Fab Report All welds are POLo unless soled Up Towards Down Away Towards & Away (BOF): Beginning of Flow Shown Left to Right 14D Quantity: 1 3 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (Up) 1 PD (Up) 1 PD (Up) G G Between 1 7-6 8-0 8-0 0-6 Run 1 7-6 15-6 23-6 24-0 14E Quantity: 1 3 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 3/4 PD (Up) 3/4 PD (Up) IH 1 PD (Down) Between 0-6 8-0 8-0 7-6 Run J 0-6 8-6 16-6 24-0 15 Quantity: 12 3 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (Up) 1 PD (Up) 1 PD (Up) GI Between I 0-6 8-0 8-0 7-6 Run I 0-6 8-6 16-6 24-0 Page Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 11(18/20 Non-Welded & Welded Main Fab Report ( LI All welds are POLa unless soled Shown Left to Right Up Towards Down Away Towards & Away (BOF): Beginning of Flow 16 Quantity: 2 2 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 1 PD (up) 1 PD (up) Gil 1k Between 0-6 8-0 3-6 Run 0-6 8-6 12-0 16A Quantity: 2 2 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = GREEN 3/4 PD (Up) 3/4 PD (Up) Gil (fG Between 0-6 8-0 3-6 Run 0-6 Pipe End Fitting 12-0 Label Qty Size Length Op Size Description Fin Run Color code = GREEN BIk Dom Sch 10 A135 GG 24' 17 4 2 1-6 GP 18 Quantity: 2 3 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' Blk G-G Color GREEN 1 PD (Up) 2 GOL40 (Up) 1 PD (Up) Gil 17-1 hG Between I 3-6 5-0 3-0 0-6 Run I 3-6 8-6 11-6 12-0 Page Titan Fire Protection, Inc. FtreList2O.27 Job: ALPHATEC - NEW BRANCHLINES #1 ____ 11/18/20 Non-Welded & Welded Main Fab Report U All welds are POLo unless noted Shown Left to Right Up Towards Down Away Towards & Away (BOF): Beginning of Flow 18A Quantity: 2 3 Outlets 2 x 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color GREEN 3/4 PD (Up) 3/4 PD (Up) Gil LJ HG 2 GOL40 (Down) Between I 3-6 5-0 3-0 0-6 Run I 3-6 8-6 11-6 Pipe End Fitting 12-0 Label Oty Size Length Op Size Description Fin Run Color code = GREEN BIk Dom Sch 40 A135 21' RN 10 2 3-0 GP 19 Quantity: 18 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = WHITE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) G H 2 GOL40 (Down) Between I 0-6 4-61/2 3-51/2 8-0 7-6 Run 0-6 5-01/2 8-6 16-6 24-0 20 Quantity: 65 3 Outlets 2 x 24-0 : Dam Sch 10 A135 GG 24' BIk G-G Color = WHITE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) Gil H G Between I 0-6 8-0 8-0 7-6 Run 0-6 8-6 16-6 24-0 Page Titan Fire Protection, Inc. FireUst2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 ____ 11/18/20 - - Non-Welded & Welded Main Fab Report r—1 c) II i) C All welds are POLO unless soled Up Towards Down Away Towards & Away (BOF): Beginning of Flow Shown Left to Right 20A Quantity: 1 4 Outlets 2 X 24-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = WHITE 3/4 PD (Up) 3/4 PD (Up) 3/4 PD (Up) 771 r_1 G fiG 2 GOL40 (Away) Between 1 0-6 8-0 8-0 1-0 6-6 Run I 0-6 8-6 16-6 17-6 I Pipe End Fitting 24-0 Label Qty Size Length Op Size Description Fin Run Color code = WHITE Bik Dom Sch 10 A135 GG 24' 20B 1 2 2-0 GG 21 Quantity: 16 2 Outlets 2 x 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = WHITE 3/4 PD (Up) 3/4 PD (Up) Gil 17-71 17-1 Between 0-6 8-0 3-6 Run 0-6 8-6 Pipe End Fitting 12-0 Label Qty Size Length Op Size Description Fin Run Color code = WHITE Bik Dom Sch 10 A135 GG 24' 22 16 2 1-6 GP 23 Quantity: 16 3 Outlets 2 X 12-0 : Dom Sch 10 A135 GG 24' BIk G-G Color = WHITE 3/4 PD (Up) 3/4 PD (Up) Gil hG 2 GOL40 (Down) Between I 3-6 5-0 3-0 0-6 Run I 3-6 8-6 11-6 12-0 Page Titan Fire Protection, Inc. FireList2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 11/18/20 77 Non-Welded & Welded Main Fab Report © All welds are POLs unless noted (BOF): Beginning of Flow Shown Left to Right Up Towards Down Away Towards& Away Pipe End Fitting Label Qty Size Length Op Size Description Fin Run Color code = WHITE BIk Dom Sch 40 A135 21' RN 35 2 3-0 GP Page 10 Titan Fire Protection, Inc. FureLlst2.O.27 Job: ALPHATEC - NEW BRANCHLINES #1 11/18/20 Outlet Fab Report Qty PartNo Size Finish Description 45 A0363191180 2 x2 BLK GOL DOM 329 A0363190166 2 x 3/4 BLK POL DOM 70 A0363190240 2 x1 BLK POL DOM 6 A0363190463 2 x 1 1/2 BLK POL DOM Page 11 Titan Fire Protection, Inc. End of printout FIreList2.O.27 EPC2cY2-D -0 VIKING FABRICATION SERVICES 6480 BOX SPRINGS BLVD Your Company Address 2 RIVERSIDE, CA 92507 951-656-3111 J13 Job Name : ALPHATEC BRANCHLINES S3 Customer : TITAN FIRE Customer ID : 250046 P.O. : 20726 Number of Heads Job Number : 6117892 Area : BRANCHLINES S3 Contract No. : Listed By : BM List Number : 3691 Stocklist Date : 11/11/20 J3j Ship To : Ship Date: Ship Via : Date Entered - 11/06/2020 Number of Main Pieces -161 Number of Outlets -433 Number of Line Pieces -0 Warehouse ID -02 Branch Code - BM Material Picksheet Page 1 JOB NUMBER: 6117892 CONTRACT NO : LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. PIPE 0 1806 1806 FT 2 X 21 DOM BLK SCH 10 DA1021GB-0200 0 1113 1113 FT 2 X 21 FGN BLK SCH 10 IA1021PB-0200 GROOV-O-LETS 0 55 55 EA 2 X 2 WELD GRV POL GR40-02000200 WELD-0-LETS 0 378 378 EA 2 X 3/4 WELD POL SL022 Material Picksheet Page 2 JOB NUMBER: 6117892 CONTRACT NO LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY :BM LOCATION AREA : BRANCHLINES S3 SPEC. INST. PIPE 0 147 147 FT 2 X 21 FGN BLK SCH 40 A135 IA4021PB-0200 MakerOn Stock List JOB NUMBER: 6117892 CONTRACT NO JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. Page 1 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 [1 ~nrr ;J399 /- BRANCH LINE RN FGN BLK SCH 40 COLOR: RED 35 2" 31-0" GP 2 NO FITTING 13 2" 31-0" GP 2 NO FITTING I! NIPPLE MAKE-ON LIST Page 1 JOB NUMBER : 6117892 CONTRACT NO LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY :BM LOCATION AREA : BRANCHLINES S3 SPEC. INST. TIIJi JLoJ. I 2" 48 Pipe Summary 3 Page 1 JOB NUMBER: 6117892 CONTRACT NO : LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. I IJX ¶LP j FGN BLK SCH 40 2" 42 7 @ 21.00 0 @ 21.00 147.00 144.00 0.00 Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. Page 1 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 MAIN I.D.QUAN. PIPE DESCRIPTION 01 2 2 FGN BLK SCH 10 ARROW: DOWN IIII0 IIUD I0I II DIV 1111010 11111II G ---- I 1101 UII 0011110110 11III 01-0" I11 1010 UlI U UI (0-9) X ---- 01-9" 2 x 3/4 WELD P.O.L. @ A ( 4-11/2 ) X ---- 4'-10 1/2" 2 x 2 WELD GR. P.O.L. @ C ( 4-11/2 ) X ---- 91-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 171-0" 2 x 3/4 WELD P.O.L. @ A (4-0) G ---- 21'-0" LENGTH EP COLOR 21'-O" GG RED HydraSCAN-V 1101 DlI lVl DIV lI0 IIV 11110IV IID 110 II TOTAL NUMBER OF WELDS: 8 MAIN I.D. QUAN. PIPE DESCRIPTION 01A 17 2 FGN BLK SCH 10 ARROW: DOWN LENGTH EP COLOR 211-0" GG RED HydraSCAN-V 11101 0II II Il lI 1111 VI II lID II G ---- 01-0" x ---- 01-6" x ---- 4'-10 1/2" x ---- 91-011 x ---- 171-0" G ---- 211-0" ( 0-6 ) 2 x 3/4 WELD P.O.L. © A ( 4-41/2 ) 2 x 2 WELD GR. P.O.L. @ C ( 4-11/2 ) 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) 2 x 3/4 WELD P.O.L. @ A ( 4-0 ) TOTAL NUMBER OF WELDS: 68 D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C1 Pipe Sketches With Welds Page 2 JOB NUMBER: 6117892 CONTRACT NO: LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 01B 1 2 FGN BLK SCH 10 191-8" GG RED ARROW: DOWN 11001 IIIUO IOI IV IIlI IV IV lID DOI I 1101110 IHUO IV lIIVII IVIV IV 1110101 I II 1101 DIII DVI IVV IIV HydraSCAN-V IID UI DlO IIV lID II G ---- 01-0" (0-6) X ---- 01-6" 2 x 3/4 WELD P.O.L. @ A ( 3-01/2 ) X ---- 3'-6 1/2" 2 x 2 WELD GR. P.O.L. @ C ( 4-11/2 ) X ---- 71-8" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 151-8" 2 x 3/4 WELD P.O.L. @ A (4-0) G ---- 191 811 TOTAL NUMBER OF WELDs: 4 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 01C 4 2 FGN BLK SCH 10 201-6" GG RED ARROW: DOWN UI III DI V IVl IV IIII 1010 IIIIVI VIV 1101 UI III VIOl V 11110 V II IV III Ul I II III DIV III ft II HydraSCAN-V II III II lID II G ---- 01-011 (0-6) X ---- 01-6" 2 x 3/4 WELD P.O.L. © A ( 3-101/2 ) X ---- 4'-4 1/2" 2 x 2 WELD GR. P.O.L. © C ( 4-11/2 ) X ---- 8'-6" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 161-6" 2 x 3/4 WELD P.O.L. © A (4-0) G ---- 201-6" TOTAL NUMBER OF WELDs: 16 1A D / B C1 CROSS SECTION © 0-0 SHOWING FTG LOCATIONS Pipe Sketches With Welds Page 3 JOB NUMBER: 6117892 CONTRACT NO : LIST NO : 3691 DATE: 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 06 11 2 FGN BLK SCH 10 161-0" GG RED ARROW: DOWN lIVID llI DID IDI II IDII DID IV llD lID IIIV IV IIHI DID IIDII I DID IIU 101 IDID II I II HydraSCAN-V IlI OIU 101010 IID IID III DID IID lID Ul G ---- 01-0" (4-0) X ---- 41-0 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A (4-0) G ---- 161-0" TOTAL NUMBER OF WELDs: 22 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 07A 1 2 FGN BLK SCH 10 51-8" GP RED ARROW: DOWN IID lII V lID IVI IV 111111 1111111111 IN 111111111111111111111111111111111111111111111111111111111111111111111111111111 UIOI HydraSCAN-V 101 U II Il Ill Dl II lID UI G ---- 01-0" (0-6) X ---- 01-6" 2 x 2 WELD GR. P.O.L. @ C ( 0-71/2 ) X ---- V-i 1/2 2 x 3/4 WELD P.O.L. @ A ( 4-61/2 ) P ---- 51-8 11 TOTAL NUMBER OF WELDs: 2 1A D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C1 Pipe Sketches With Welds Page 4 JOB NUMBER: 6117892 CONTRACT NO: LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 08 11 2 FGN BLK SCH 10 101-6" GG RED ARROW: DOWN IID 111111111111111 IN 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 III II II I HydraSCAN-V II IlU VI II II Il G ---- 01-0" (2-0) X ---- 21 011 2 x 3/4 WELD P.O.L. @ A X ---- 31-1" 2 x 2 WELD GR. P.O.L. @ C ( 6-11 ) X ---- 101-011 2 x 3/4 WELD P.O.L. @ A (0-6) G ---- 101-6" TOTAL NUMBER OF WELDs: 33 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 09 4 2 FGN BLK SCH 10 51-6" GG BLUE ARROW: DOWN IIV IIII DIV IVl lU III 10101111 L 1101 llIHDI DOII I IlUl IIV IU I II 1101 II I II II HydraSCAN-V IlU VI II 110 II G ---- 0I011 (2-0) X ---- 21-0" 2 x 3/4 WELD P.O.L. @ A ( 0-71/2 ) X ---- 2'-7 1/2 2 x 2 WELD GR. P.O.L. @ C ( 2-101/2 ) G ---- 51-6" TOTAL NUMBER OF WELDs: 8 1A D / B C1 CROSS SECTION @ 0-0 SHOWING FIG LOCATIONS Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. Page 5 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 09A 4 2 FGN BLK SCH 10 181-6" GG BLUE ARROW: DOWN HydraSCAN-V G ---- O'-O" ( 2-0 ) X ---- 21-0" 2 x 3/4 WELD P.O.L. © A ( 0-71/2 ) X ---- 2'-7 1/21! 2 x 2 WELD GR. P.O.L. @ C ( 7-41/2 ) X ---- 101-0" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 181-0" 2 x 3/4 WELD P.O.L. © A (0-6) G ---- 181-6 11 TOTAL NUMBER OF WELDs: 16 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 09B 4 2 FGN BLK SCH 10 101-6" GG BLUE ARROW: DOWN HydraSCAN-V 1111111111111111111111 IN 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 100 II0 Il0 III 0ID II0 lID II G ---- 01-0" (2-0) X ---- 2'-0" 2 x 3/4 WELD P.O.L. © A ( 0-71/2 ) X ---- 2'-7 1/2" 2 x 2 WELD GR. P.O.L. © C ( 7-41/2 ) X ---- 103-0" 2 x 3/4 WELD P.O.L. @ A (0-6) G ---- 10'-6" TOTAL NUMBER OF WELDs: 12 D / B CROSS SECTION © 0-0 SHOWING FTG LOCATIONS C' Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION 10 4 2 FGN BLK SCH 10 ARROW: DOWN IIDlI 0 IIlD lDI II G ---- ID IllD IV IIH IIIlMI V 1011101 II DIV IV 01-011 110 III IIIl DIV III II (4-6) X ---- 41 61I 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-6 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 201-6 2 x 3/4 WELD P.O.L. @ A (0-6) G ---- 211-011 Page 6 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 LENGTH EP COLOR 211-0 GG BLUE HydraSCAN-V IlDI DII IVU OlD IIV IIV III VIV IID IIII TOTAL NUMBER OF WELDS: 12 1A D ' / B CROSS SECTION @ 0-0 SHOWING FIG LOCATIONS C Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. Page 7 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 MAIN I.D. QUAN. PIPE DESCRIPTION 02.1 1 2 DOM BLK SCH 10 ARROW: DOWN IIIIH II0l U01 Il G ---- III IIIlI0Il0l0 10 lIO liD IIUO UO III 01-0" IIl IV UO 1110 101 I U ( 1-111/2 ) X ---- i'-il 1/2" 2 x 2 WELD GR. P.O.L. @ B ( 2-01/2 ) X ---- 41-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 201-0" 2 x 3/4 WELD P.O.L. @ A (1-0) G ---- 211-0" LENGTH EP COLOR 211-0" GG RED HydraSCAN-V 1101 DIl I0l Di V Il0 Il0 IIl VIV II lID II TOTAL NUMBER OF WELDS: 4 MAIN I.D. QUAN. PIPE DESCRIPTION 02A.1 22 2 DOM BLK SCH 10 ARROW: DOWN lIDIIH II0l 1 III IDIl DID ID IlD lID IIID ID IIDl IM IV IV Iil III DI IDV 1110 III 0 II G ---- 01-0" (4-0) X ---- 41-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 20'-0" 2 x 3/4 WELD P.O.L. @ A ( 1-0 ) G ---- 21'-0" LENGTH EP COLOR 211-0" GG RED HydraSCAN-V TOTAL NUMBER OF WELDS: 66 D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO : JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION : SPEC. INST. Page 8 LIST NO : 3691 DATE : 11/11/20 BY : BM AREA : BRANCHLINES S3 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 02B.1 1 2 DOM BLK SCH 10 21'-0" GG RED ARROW: DOWN II0II 0 Il0! 101 III II IV IVI IIFIVII VIVID UIH 110 IlUD UD DM1 IIU UD D 1110 DI I UI HydraSCAN-V 1101 DII ID 010 II ID 1111 VD ID 110 UI G ---- 0'-0" (2-9) X ---- 21-9" 2 x 2 WELD GR. P.O.L. @ D ( 1-3 ) X ---- 41-0" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 201-0" 2 x 3/4 WELD P.O.L. @ A ( 1-0 ) G ---- 21'-0" TOTAL NUMBER OF WELDS: 4 MAIN I.D. QUAN. PIPE DESCRIPTION 03.1 9 2 DOM BLK SCH 10 ARROW: DOWN IlIUM IIVI 101 Il IVII DIV IV IIM 110 1110 UV DVI III 1010 DID ID DIII DIV DI V UI G ---- 01-0 11 (4-0) X ---- 41-0" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 201-0" 2 x 3/4 WELD P.O.L. @ A (1-0) G ---- 211 01' LENGTH EP COLOR 211-0" GG RED HydraSCAN-V TOTAL NUMBER OF WELDS: 27 1A D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C1 Pipe Sketches With Welds Page 9 JOB NUMBER: 6117892 CONTRACT NO : LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 03A.1 1 2 DOM BLK SCH 10 211-0" GG RED ARROW: DOWN IIOII O IIOI 101 II I0O 01010 IIII0 III 1101 IM 110111010 IlI III 1010111011 I II HydraSCAN-V 1101 II Il 010 lI II III I II II II G ---- 0'-0" (4-0) X ---- 41-0" 2 x 3/4 WELD P.O.L. @ A ( 4-51/2 ) X ---- 8'-5 1/2" 2 x 2 WELD GR. P.O.L. © B ( 3-61/2 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 201-0" 2 x 3/4 WELD P.O.L. @ A ( 1-0 ) G ---- 211-0" TOTAL NUMBER OF WELDS: 4 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 03B.1 1 2 DOM BLK SCH 10 211-0" GG RED ARROW: DOWN HydraSCAN-V 110110 1101 1111 hF 1011 010111 lID 111111111 101111001111 I II Ill I 101110101 I II III II 11101111 1101111 II lID II G ---- 01-0" (4-0) X ---- 41-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A ( 4-6 ) X ---- 161-6" 2 x 2 WELD GR. P.O.L. @ B ( 3-6 ) X ---- 201-0" 2 x 3/4 WELD P.O.L. @ A ( 1-0 ) G ---- 211-0" TOTAL NUMBER OF WELDS: 4 D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C1 Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION 04.1 11 2 DOM BLK SCH 10 ARROW: DOWN Page 10 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 LENGTH EP COLOR 211-0" GG RED HydraSCAN-V II IOII IDI DID IID IID IlU HID IlD IIII G ---- 01-0" x ---- 41-0" x ---- 121-0" x ---- 201-0" G ---- 211-0" ( 4-0 ) 2 x 3/4 WELD P.O.L. © A ( 8-0 ) 2 x 3/4 WELD P.O.L. © A ( 8-0 ) 2 x 3/4 WELD P.O.L. © A ( 1-0 ) TOTAL NUMBER OF WELDS: 33 MAIN I.D. QUAN. PIPE DESCRIPTION 05.1 1 2 DOM BLK SCH 10 ARROW: DOWN LENGTH EP COLOR 211-0 GG RED HydraSCAN-V IIDI OII IOU DID II II IlU HI lID II G ---- 01-0" x ---- 41-0 11 x ---- 61-0" x ---- 121-0" x ---- 20'-0" G ---- 211-0 11 ( 4-0 ) 2 x 3/4 WELD P.O.L. © A ( 2-0 ) 2 x 2 WELD GR. P.O.L. © D ( 6-0 ) 2 x 3/4 WELD P.O.L. © A ( 8-0 ) 2 x 3/4 WELD P.O.L. @ A ( 1-0 ) TOTAL NUMBER OF WELDS: 4 1A D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS Pipe Sketches With Welds Page 11 JOB NUMBER: 6117892 CONTRACT NO: LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 05A.1 9 2 DOM BLK SCH 10 211-0 GG RED ARROW: DOWN MII0II 0 IIHI 101 II IOU VIVID IIll lID IlUD ID III IMID ID III 1 lUU lU IDUD III 0 II HydraSCAN-V 1101 II II II II IlU DI II lID II G ---- 01-0" (4-0) X ---- 41-0 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-0 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 201-0 2 x 3/4 WELD P.O.L. @ A ( 1-0 ,) G ---- 211-0" TOTAL NUMBER OF WELDS: 27 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 05B.1 1 2 DOM BLK SCH 10 211-0" GG RED ARROW: DOWN IIOftD IIDl 101 II IDII DIV IV IID 110 IIUV 101110 IU lI II IM IlI IU I II HydraSCAN-V III UI II DI V II II IlU DI I II lI G ---- 01-0 11 (4-0) X ---- 41-0" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 121-0" 2 x 3/4 WELD P.O.L. @ A ( 1-41/2 ) X ---- 13'-4 1/2 2 x 2 WELD GR. P.O.L. @ D ( 6-71/2 ) X ---- 201-0 2 x 3/4 WELD P.O.L. © A ( 1-0 ) G ---- 211-0" TOTAL NUMBER OF WELDS: 4 1A C' D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCH LINES S3 LOCATION SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION 10B.1 6 2 DOM BLK SCH 10 ARROW: DOWN IIIIH III II II G ---- IV IIIV IV III IIII V 1 IIIDID IIII VIV 01-0" III IV III IIV II I II (7-6) X ---- 71-6" 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 151-6" 2 x 3/4 WELD P.O.L. © A (5-6) G ---- 211-0" Page 12 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 LENGTH EP COLOR 211-0" GG BLUE HydraSCAN-V 1101 IIlVI DIV IID IIV IlU VIV IIV lID II TOTAL NUMBER OF WELDS: 12 MAIN I.D. QUAN. PIPE DESCRIPTION 10B.2 6 2 DOM BLK SCH 10 ARROW: DOWN lIIIll0I 1 VIUII II DIV IV II lID IIl II VI Il III 0 II VI IV ftV liii VI lID lID I Il G ---- 01-0" (2-6) X ---- 21-6" 2 x 3/4 WELD P.O.L. @ A (0-6) G ---- 31-0" LENGTH EP COLOR 31-0" GG BLUE Hyd raSCAN -v Ilul II II II liii II lID II TOTAL NUMBER OF WELDS: 6 1A D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C1 Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION 11.1 1 2 DOM BLK SCH 10 ARROW: DOWN 1111111111111111111111 IN 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 G ---- 01-0" Page 13 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 LENGTH EP COLOR 211-0" GG BLUE HydraSCAN-V IlIlIlDU DID IlD IlD IlU DID IID lID II ( 5-21/2 ) X ---- 5'-2 1/2" 2 x 2 WELD GR. P.O.L. @ B ( 2-31/2 ) X ---- 71-6" 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 151-6" 2 x 3/4 WELD P.O.L. @ A (5-6) G ---- 211-0" TOTAL NUMBER OF WELDS: 3 MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 11.2 1 2 DOM BLK SCH 10 31-0" GG BLUE ARROW: DOWN HydraSCAN-V lID IUD IlDl IDI Ill lIVID ID lID 1101101101 II III DV 111010 111101 ID UIID UID U UI liii DI IDO lID lID Ill DID lID lID UI G ---- 01-011 (2-6) X ---- 2'-6" 2 x 3/4 WELD P.O.L. @ A (0-6) G ---- 31-0" TOTAL NUMBER OF WELDS: 1 D / B CROSS SECTION @ 0-0 SHOWING FTG LOCATIONS C' Pipe Sketches With Welds JOB NUMBER: 6117892 CONTRACT NO JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION 11A.1 6 2 DOM BLK SCH 10 ARROW: DOWN II0II 0 IIDI 10111010 G ---- III0 IV III IM 1010 III I 1011 II0 01-0" II Il II IUIO II I II (7-6) X ---- 7'-611 2 x 3/4 WELD P.O.L. © A ( 8-0 ) X ---- 151-6 2 x 3/4 WELD P.O.L. @ A (5-6) G ---- 211-0" Page 14 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 LENGTH EP COLOR 211-0" GG BLUE HydraSCAN-V 1101 VII 101 DIV 110 lID III DID lID 11011 TOTAL NUMBER OF WELDS: 12 MAIN I.D. QUAN. PIPE DESCRIPTION 11A.2 6 2 DOM BLK SCH 1O ARROW: DOWN 1111101101 101 III Ill DID IV III ID III 1011 1011011111111 DII Ill U III 1010 UID UI UI G ---- 0-0" (2-6) X ---- 21-6" 2 x 3/4 WELD P.O.L. @ A (0-6) G ---- 31-0 11 LENGTH EP COLOR 31-0" GG BLUE HydraSCAN-V 1111 001100 II II III Il II lID III TOTAL NUMBER OF WELDS: 6 MAIN I.D. QUAN. PIPE DESCRIPTION 12.1 5 2 DOM BLK SCH 10 ARROW: DOWN 111I1llIIIVII 101110101110101110 III IV ID 1111 DIII DIII 1110 1111101101111111110111 III Ill G ---- 01-0 11 (7-6) X ---- 71-6 2 x 3/4 WELD P.O.L. @ A ( 8-0 ) X ---- 151-611 2 x 3/4 WELD P.O.L. © A (5-6) G ---- 211-0" LENGTH EP COLOR 21'-0" GG BLUE HydraSCAN-V 11111111111101111111111 III III 111111 III TOTAL NUMBER OF WELDS: 10 Pipe Sketches With Welds Page 15 JOB NUMBER: 6117892 CONTRACT NO LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY :BM LOCATION AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 12.2 5 2 DOM BLK SCH 10 31-0" GG BLUE ARROW: DOWN HydraSCAN-V IID IIH IIDIIDI IIIII VIVID IlI II II IllIDiII IID III DI II IDI 1 VIUID lID I Il IIII llI IDD IID lID IlI lD IID lID ft G ---- 01-0 11 x ---- 21-6" G ---- 31-0" ( 2-6 ) 2 x 3/4 WELD P.O.L. @ A ( 0-6 ) TOTAL NUMBER OF WELDS: 5 NONTWELDED PIPE Page 16 JOB NUMBER: 6117892 CONTRACT NO: LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY :BM LOCATION AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP COLOR 07 23 2 FGN BLK SCH 10 21-6" GP RED NON-WELDED PIPE Page 17 JOB NUMBER: 6117892 CONTRACT NO LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY :BM LOCATION AREA : BRANCHLINES S3 SPEC. INST. MAIN I.D. QUAN. PIPE DESCRIPTION LENGTH EP 02.2 1 2 DOM BLK SCH 10 31-0 GG 02A.2 22 2 DOM BLK SCH 10 31-0" GG 02B.2 1 2 DOM BLK SCH 10 3'-0" GG 03.2 9 2 DOM BLK SCH 10 31-0" GG 03A.2 1 2 DOM BLK SCH 10 31-0" GG 03B.2 1 2 DOM BLK SCH 10 31-0" GG 04.2 11 2 DOM BLK SCH 10 31-0" GG 05.2 1 2 DOM BLK SCH 10 31-0" GG 05A.2 9 2 DOM BLK SCH 10 31-0 GG 05B.2 1 2 DOM BLK SCH 10 31-0" GG COLOR RED RED RED RED RED RED RED RED RED RED Pipe Sketch Summary 1 JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. WI L7 T"Ti 01 2 2 FGN BLK SCH 10 01A 17 2 FGN BLK SCH 10 01B 1 2 FGN BLK SCH 10 01C 4 2 FGN BLK SCH 10 06 11 2 FGN BLK SCH 10 07 23 2 FGN BLK SCH 10 07A 1 2 FGN BLK SCH 10 08 11 2 FGN BLK SCH 10 09 4 2 FGN BLK SCH 10 09A 4 2 FGN BLK SCH 10 09B 4 2 FGN BLK SCH 10 10 4 2 FGN BLK SCH 10 Page 1 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 H?1) 21'-O" GG 2V-0" GG 19'-8" GG 20'-6" GG 16'-O" GG 2'-6" GP * 5!811 GP 10'-6" GG 5t6!I GG 18'-6" GG 10I6!1 GG 21'-0 GG Pipe Sketch Summary 1 JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. Page 2 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 02.1 1 2 DOM BLK SCH 10 211 011 02.2 1 2 DOM BLK SCH 10 31 011 02A.1 22 2 DOM BLK SCH 10 211-0" 02A.2 22 2 DOM BLK SCH 10 31-0" 02B.1 1 2 DOM BLK SCH 10 211-0" 02B.2 1 2 DOM BLK SCH 10 31-0" 03.1 9 2 DOM BLK SCH 10 211 011 03.2 9 2 DOM BLK SCH 10 31-0" 03A 1 1 2 DOM BLK SCH 10 211-0 03A.2 1 2 DOM BLK SCH 10 31-0" 03B.1 1 2 DOM BLK SCH 10 211-0" 03B.2 1 2 DOM BLK SCH 10 31-0" 04.1 11 2 DOM BLK SCH 10 211-0" 04.2 11 2 DOM BLK SCH 10 31-0 05.1 1 2 DOM BLK SCH 10 211-0" 05.2 1 2 DOM BLK SCH 10 3'-0" 05A 1 9 2 DOM BLK SCH 10 211-0" 05A.2 9 2 DOM BLK SCH 10 31-0" 05B.1 1 2 DOM BLK SCH 10 211 011 05B.2 1 2 DOM BLK SCH 10 31-0 10B.1 6 2 DOM BLK SCH 10 211-0 10B.2 6 2 DOM BLK SCH 10 31-0" 11.1 1 2 DOM BLK SCH 10 2110u 11.2 1 2 DOM BLK SCH 10 31-0" 11A.1 6 2 DOM BLK SCH 10 211-0 11A.2 6 2 DOM BLK SCH 10 31-0" 12.1 5 2 DOM BLK SCH 10 211-0" 12.2 5 2 DOM BLK SCH 10 31-0" J47 GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG Pipe Sketch Summary 4 JOB NUMBER: 6117892 CONTRACT NO JOB NAME : ALPHATEC BRANCHLINES 53 LOCATION SPEC. INST. Page 1 LIST NO : 3691 DATE :11/11/20 BY :BM AREA : BRANCHLINES S3 FGN BLK SCH 10 2" 86 53 @ 21.00 0 © 0.00 1113.00 1077.33 2.00 I DPW 11L 2" 86 Pipe .Sketch Summary 4 Page 2 JOB NUMBER: 6117892 CONTRACT NO : LIST NO : 3691 DATE : 11/11/20 JOB NAME : ALPHATEC BRANCHLINES S3 BY : BM LOCATION : AREA : BRANCHLINES S3 SPEC. INST. I - - H DOM BLK SCH 10 211 150 86 @ 21.00 0 © 0.00 1806.00 1800.00 0.00 1KJZL 2" 150 RawMaterials List JOB NUMBER: 6117892 CONTRACT NO: JOB NAME : ALPHATEC BRANCHLINES S3 LOCATION SPEC. INST. Page 1 LIST NO : 3691 DATE : 11/11/20 BY :BM AREA : BRANCHLINES S3 I PIPE 1806 FT 2 X 21 DOM BLK SCH 10 1 DA1021GB-0200 1113 FT 2 X 21 FGN BLK SCH 10 2 IA1021PB-0200 147 FT 2 X 21 FGN BLK SCH 40 A135 3 IA4021PB-0200 GROOV-O-LETS 55 EA 2 X 2 WELD GRV POL WELD-O-LETS 378 EA 2 X 3/4 WELD POL GROOVE BOTH ENDS 212 EA G.B.E. 2 GROOVE ONE END 72 EA GRV&PL-END 2 WELDS 378 EA WELD 2 X 3/4 55 EA WELD X2 CUT FABRICATION 278 EA PIPE CUT 2 4 GR40-02000200 5 5L022 6 9211000020 7 9209000020 8 9240202007 9 9240202020 10 9240100020 Total weight: 8386.7100 NIKING fVC, 07-0 Viking Group, Inc. FABRICATION SERVICES * RIVERSIDE, CA WAR N! NG FITTINGS ON ALL THREADED PIECES LESS THAN 411 LONG WILL BE HAND TIGHT. THANK YOU. VIKING FABRICATION SERVICES VFSRIVERSIDE@SUPPLYNET.COM PHONE: 951-656-3111 * FAX: 951-656-2606 NIKING * VIKING FABRICATION SERVICES LLC 01JIt II ItS.1tuJ 11 [ 09 I 'lii 1 1.0 WELDING A. GENERAL: All welding to follow procedures as set forth by VIKING FABRICATION SERVICES and will work to be in compliance with the following standards. American Welding Society Standard AWS B2.1. National Fire Protection Association Standard NFPA 13 "Installation for Sprinkler Systems". National Fire Protection Association Standard NPA SiB, "Standard for Fire Prevention in use of cutting welding processes". State, local and city codes. B. PROCEDURE: Prior to any welding or cutting in the welding fabrication shop, it's the responsibility of the welder to check all his equipment for safety and that any combustible materials within 35 feet if the operation is either removed or shielded, The general superintendent or the staff welding supervisor of the company confirms that prior to any operation, welding or cutting that there is adequate ventilation throughout the welding shop area and that all safety precautions are in compliance. All holes in piping required for welding of pipe-o-lets, threads-o-lets or stock-o-lets, in lieu of tees, are to be cut with a plasma machine, The size of the hole is exactly the same diameter as the internal diameter (1.0.) of the approved Lii Fitting. No fitting shall be modified whatsoever. The coupon and/or disk us the removed by magnet, completely removing any foreign objects from the pipe. The hole is then cleaned, removing any residue by means of a chipping hammer and file so as to guarantee a smooth bore and clean surface for welding. Fitting is then placed over the hole making sure it does not penetrate the internal diameter of the piping causing flow restrictions and then the fitting is leveled in both directions prior to tacking. One tack weld is then made and again fitting is leveled. When level, two (2) more tack welds are made, making three (3) tack welds in all and level checked again. UPDATED: 6/5/2020 Final welding of the fitting IS then accomplished by using .035 or .045 gauge wire conforming to AWS specification no. ER07S-3 from AWS ASiB. The fitting is welded all around with a fillet weld. All slag and welding residue is removed and the weld inspected to ensure there is no visible slag or residue holes and there is a clear flow area. The staff welding superintendent inspects the welding fitting and flow are to verify that it meets the company requirements and specifications as well as codes. Stamping of the pipe with the welders identification imprint is then accomplished only after approval by the staffs welding superintendent. If the staffs welding superintendent disapproves of any impairment abnormally or encroachment of the weld, fitting or section of the pipe where the weld was performed. It is then destroyed by means of cutting it to guarantee the fitting and/or pipe cannot be used. The staff welding superintendent and the welder is responsible for the destroying the rejected pipe and welded fittings. Steel plates are not to be welded to the end of the pipe or fitting. Nuts, clips, eye rods, angle brackets or any other fasteners shall not be welded to the pipe or fitting. Torch cutting and welding shall not be permitted as a means of modifying or repairing sprinkler systems. 20.. Welder's identification imprint to be:: S, J, R, or V..: C. INSPECTIONS: The general superintendent prior to any welded pipe leaving the welding shop ready to be taken to the field will check fittings and welds to ensure that all company procedures and standards satisfy code requirements and are in compliance with same. UPDATED: 6/5/2020 WELDER PERFORMANCE QUALIFICATION (WPQ) Welder's Name Saulo Solorzano Zamora Identification No. S Test Description WPS Followed VFS_WPS_5010 Test Coupon i:i Production Weld Date Welded 2/7/2020 Specification & type/grade of base metal(s) A36 Thickness 1/2" Variables and Qualification Limits Welding Variables Welding Process(es) Type (i.e.; manual, semi-automatic used) Backing (with/without) Plate X Pipe (enter diameter)- Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) (info. Only) Filler metal or electrode specification Is) (Info. Only) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW-S 3 layers min Yes X No Process 2 GMAW-G 3 layers mm )( Yes No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GIAW, PAW, GMAW) Transfer mode (GMAW) Actual Values GMAW Semi-Automatic Without 8'x6"x0.5" 1/2" P1-P1 AS.18 ER7OS 6 F.6 1/8 INCH 1/8 INCH 2G N/A N/A Short Circuit & Spray/Globular e Qualified GMAW Semi-Automatic Without 1" - 24" Pipe, All Plate 3/64"-UT P1 thru P151, P4, P41 thru P49 F.6 3/8 INCH 3/8 INCH Fillet F,H; Groove Pipe s 24" F, H N/A L N/A [ All Results I Visual examination of completed weld SATISFACTORY Transverse face and root bends Er Longitudinal bends IN Side bends 0 Pipe specimen, macro test for fusion 11 Plate specimen, macro test for fusion Type Result Type Result - I Type Result SIDE BEND (OW- SATISFACTORY 161.1/QW-163) SIDE BEND (QW- SATISFACTORY 161.1/QW-163) Alternative Volumetric Examination Results N/A Fillet weld - fracture test N/A Length and percent of defects 0 Fillet welds in plate [_J Fillet welds in pipe Macro examination Fillet size (in.) x Concavity or convexity (in,) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SZ,.2G_1 Welding supervised by - Gonzalo Cruz We certify that the statements in this record are correct and tha t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure and Performance Qualificatio n . Organization Viking Fabrication Services Date 2 /1 LI . Ccrtfied by. LucaB A Crumley . . CWI 17070491 OCt EXP 7/112023 WELDER PERFORMANCE QUALIFICATION WPQ Welder's Name Sauto Solorzano Zamora -. Identification No. Test Description WPS Followed VFS_WPSJOOZ D Test Coupon EQ Production Weld bate Welded 8/18/2019 Specification & type/grade of base metal(s) A1S/A795 Thickness SCH 7 Testing Variables and qualification Umits Welding Variables (QW-350) Actual Values Range Oalffled Welding Process(es) GMAW GMAW Type (Le. manual, semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate - Pipe (enter diameter) X 2 7/8" UT Base Metal Thickness SCH 7 SCH 7 Base metal P Number to P Number P1 Pt - Pt thru PISF P34 P41 thru P49 Filler metal or electrode specification(s) (SEA) (Info, Only) A5.19 Filler metal or electrode specification(s) (info. Only) ER70S6 Filler metal F-Number(s) F,6 F.6 Deposit thickness for each process Process 1. GMAW 3 layers mlii F1 Yes No 1/4 INCH s 3/8 INCH Position(s) Special Position Special Position & Flat for rm.tt Vertical progression (uphill or downhill) Both Both Use of backing gas (GTAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) (lobular Pulse Spray/Globular/Spray Results Visual examination of completed weld SATISFACTORY EJ Transverse face and root bends U Longitudinal bends Li Side bends Pipe specimen, macro test for fusion LJ Plate specimen, macro test for fusion lonj Type Result Type Result Type Result Alternative Volumetric Examination Results: N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE 0 Fillet welds in plate N Fillet welds in pipe Macro examination SATISFACTORY Fillet s i z e ( i n . ) 5/16 x 1/4 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crurnley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SS.4) Welding supervised by Gonzola Cruz We certify that the statements in this record ar e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Secti o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance qualification. Organization Viking Fabrication Services Date //' /29l1 Certified bV .. ,....... Lucas ACundey . OWl .17070491 v'C1. EXP. 7/1020 Actual Values GMAW emi-Automati Without 1.25" 5017 Pi-Pi A518 ER7OS-6 GMAW Semi-Automatic with/Without 1-27/8" SCH 7 P1 thru P1SF, P34, P41 thru P49 P.6 1/4 INCH s 3/8 INCH Special Position specIal Position & Flat for Fillets Both Both Pulse WELDER PERFORMANCE QUAUFIcATION WPQ) Welders Name Saulo Solorzano Zamora Identification No - - S Test Description WPS Followed VFS_WPS 7004 [J Test Coupon M Production Weld Dat e W e l d e d 8/28/2019 Specification & type/grade of base metal(s) A135-A795 Thickness SCH 7 Variables and Qualification Limits Variables Welding Process(es) Type (Le.; manual, semi-automatic used) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(3) (SFA) (Info. Only) Filler metal or electrode speelfkation(si (Info. Onl y ) Filler metal F-Number(s) Deposit thickness for each process PrOcess 3. GMAW S layers min i:i Yes RXNo Position(s) Vertical progression (uphill or downhill) Use of backing gas (GIAW, PAWS GMAW) Transfer mode (GMAW) Visual examination of completed weld SATISFACTORY Transverse face and coot bends U Longitudinal bends (_J Side bends Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusion 44 Type Result Type Result Type Result Alternative Volumetric Examination Jesu i t s : r4l A, Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE EJ Fillet welds in plate N Fillet welds In pipe Macro examination SATISFACTORY Fill e t s i z e ( i n . ) 7/32 x 1/4 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SS_12 Welding supervised by Gonzalo Cruz We certify that the statements In this reco r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements of S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Qualification , Organization Viking Fabrication Services Date Lucas ACrumi.y .. OWl 11010401 WELDER PERFORMANCE QUALIFICATION (WPQ) Welder's Name Saulo Soiorzano Zamora identification No S Test DescriptIon WPS Followed VFS WPS 7004 F1 Test Coupon Production Weld Date Welded 8/8/2019 Specification & type/grade of base metal(s) A135A795 Thickness SCI4 10 T Variables and Qualification Limits Variables Actual Values Range Qualified Welding Process(es) ovAAw GMAW Type (i.e.; manual semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X 1.25" 1"-2 7/8w Base Metal Thickness - SCH 10 SCH 10 Base metal P-Number to P-Number Pi-pi Pt ttvu PSSF, P34, P41 thru P49 Filler metal or electrode specification(s) (SM) (Info, O n l y ) AS.18 Filler metal or electrode specification(s) (Info. Only) ER7OS.6 Filler metal F-Number(s) F.6 Deposit thickness for each process Process 1 GMAW 3 layers min MYes MX No 1/4 INCH s3/8 INCH Position(s) Special Position Spd;l Position & Flat for FIU,ts Vertical progression (uphill or downhill) Both Both Use of b*cklng gas (GTAW, PAW, GMAW) N/A Transfer mode (GMAW) Pulse Sovav/GIobular1Spra Visual examination of completed weld SATISFACTORY Transverse face and root bends Lj Longitudinal bends U Side bends Pipe specimen, macro test for fusion El Plate specimen, macro test for fusion I TVDe I Result I TyPe I Result I Type I Result Alternative Volumetric Examination Results: Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE 0 Fillet welds In plate C& Fillet welds in pipe Macro examination SATISFACTORY Fillet s i z e ( I n . ) 114 x 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SS,119 Welding supervised by Gonzalo Cruz We certify that the statements In this record are correct and that the test coupons were prepar e d , w e l d e d , a n d tested In accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE & AWS B2.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date Cf Certified by CM 17070491 ---i" QC1 EXP 71142020 . C..-. WELDER PERFORMANCE QUALIFICATION (W P Q Welders Name Saulo Solorzano Zamora identification No S Test Description WPS Followed VFS_WPS_7002 0 Test Coupon Production Weld Date Welded _8/8/019 Specification & type/grade of base metal(s) A135/A795 Thickness 501 10 Testing Variables and Qualification Limits Welding Variables (QW-350) Actual Values Range Qualified_____ Welding Process(es) Type (i.e.; manual, semi-automatic used) Backing (with/without) Base Metal Thickness Base metal P-Number to P-Number Fillet metal or electrode specification(s) (SPA) (info. Only) Filler metal or electrode speclflcaUon(s) (in fo. Only) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 layers min n Yes nX No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GTAW, PAW, GMAW) Transfer mode (GMAW) GMAW - GMAW Semi-Automatic Semi-Automatic Without With/Without Plate - Pipe (enter diameter) 4P 2 7/8 .LIT SOliD 50110 P1. Pt P1 thru PI.SF, P34, P41 thru P49 AS.18 ER70S-S F6 P6 1/4 INCH t 3/8 INCH Special Position Sgeclsl position & ;latfov cWets - Both Both N/A N/A Globular Pulse Spray/Globular/Spray Visual examination of completed weld SATISFACTORY Transverse face and root bends U Longitudinal bends U Side bends SIC Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type I Result I Type I Result I Type I Result Alternative Volumetric Examination Results: N/A Fillet weld fracture test SATISFACTORY length and percent of defects NONE i:i Fillet welds in plate N Fillet welds in pipe Macro examination SATISFACTORY Fillet si z e ( i n , ) 5/1.6 x 9/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by - Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SS_4,10 Welding supervised by Gonzola Cruz We certify that the statements in this record a r e c o r r e c t a n d t h a t t h e t e s t CDUPOfl5 were prepared, welded, and tested In accordance with the requirements of Secti o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Qualifi c a t i o n , Date Organization Certified by '. Lucas A CINI .17070.491 oci EXP. 711r2O20'!jj : .- Fabrication Services WELDER PERFORMANCE QUALIFI C A T I O N ( W P Q Welder's Name Saulo Solorzano Zamora identification No. S Test Description WPS Followed VFS_WPSJ002 0 Test Coupon Production Weld Date Welded 8/28/2019 kZj Specification & type/grade of base meta l ( s ) A53 Thickness SCH 40 Variables and Qualification Limits Variables Welding Process(es) Type (i.e.; manual, semi-automatic us e d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) (info. Only) Filler metal or electrode specification(s) (Info. Only) Filter metal F-Number(s) Deposit thickness for each process Process I GMAW 3 layers mi 11 n Yes Mv No Position(s) Vertical progression (uphill or dow n h i l l ) Use of backing gas (6TAW, PAW, GM A W ) Transfer mode (GMAW) Actual Values Range Qualified GMAW GMAW Semi-Automatic Semi-Automatic Without With/Without 4U 27/8" -UT SCH 40 SCH 40 P1-P1 tliru P1St, P4, P41 thru £49 AS.1$ ER705-6 F.6 F.6 1/4 INCH eA 3/8 INCH Special Positioi ;pedal Position & Fiat for PKWU Both Both Results Visual examination of completed we l d SATISFACTORY 0 Transverse face and root bends Lj Longitudinal bends Lj Side bends Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusi o n Alternative Volumetric Examination R e s u l t s : Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE Fillet welds in plate Fillet welds in pipe Macro examination SATISFACTO R Y F i l l e t s i z e ( i n . ) 5/16 * 9/32 Concavity at convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. SS4,,,40 Welding supervised by Gonzola Cruz We certify that the statements in thi s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d w e l d e d , a n d tested In accordance with the requirem e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82,1 SpecIfication for Welding Procedu r e a n d P e r f o r m a n c e Q u a l i f i c a t i o n . Organization Viking Fabrication SQMCeS Date jJie I'i't If by C" - 1170704411 .••;•• WELDER PERFORMANCE QUALIFICATION (WP Q ) Welder's Name Saulo Solortano Zamora Identification No. S Test Description WPS Followed - VFSWPS 7004 Test Coupon Production Weld Lai Specification & type/grade of base metal( s ) A135-A795 Variables and Qualification Umits Date Welded 8/28/2019 Thickness 5CR 40 Variables Welding Process(es) Type (Le.; manual, semi-automatic used) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode s p e c i f i c a t i o n ( s ) (SEA) (Info. Only) Filler metal or electrode specification(s ) (info. Only) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 layers min [3 Yes El No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GTAWI PAW, GMAW) Transfer mode (GMAW) Actual Values Range Qualified GMAW GMAW Semi-Automatic Semi-Automatic Without With/Without 1.25" 1"-27/8' 50440 SCH40 P1-Pi P1 thru 1`15F. P34, P41 thru P49 AS.18 ER70S-6 F.6 f.6 1/4 INCH S 3/8 INCH Special Position Special PosUon & Fiat to, Fillets Both Both N/A N/A Globular Pulse Spray/Globular/Spray Results 1 Visual examination of completed weld SATISFACTORY [3 Transverse face and root bends [j Longitudinal bends 1j Side bends 6~1 Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusion Alternative Volumetric Examination ReSUItS njok Fillet weld - fracture test SATISFACTORY length and percent of defects NONE 11 Fillet welds in plate Q Fillet welds in pipe Macro examination SATISFACTO R Y F i l l e t s i z e ( I n . ) 1/4 x 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no, SS,140 Weldinit suoervised by Gonzalo Ctuz We certify that the statements In th i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t coupons were prepared, welded, and tested in accordance with the requirements o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.3. Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date 'J 14 /2.iJ( kr 'LucesACrumley AW •:cwt .17070491 WELDER PERFORMANCE QUALIFIC A T I O N ( W P Welder's Name Jose Guiterrer Identification No 1 Test Description WPS Followed VFSWPSJQQ2 Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of base metal( s ) AI35/A795 Thickness SCM 7 Testing Variables and Qualification Limits Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automati c u s e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 4" 2 7/8" - UT Base Metal Thickness SCM 7 SCM 7 Base metal P-Number to P-Number PI-P3. P1 thru PiSc, P34, P4thtu P49 Filler metal or electrode speciflcatlon() ( S P A ) ( I n t o . O n l y ) A5.18 Filler metal or electrode specification(s) ( i n f o . O n l y ) ER70S-6 Filter metal F-Number(s) F.6 P.6 Deposit thickness for each process Process 1 GMAW 3 layers ml 11 n Yes El No 1/4 INCH 1318 INCH Position(s) Special Position Special PoiUen & Fist tot Fillets Vertical progression (uphill or down h i l l ) Both Both Use of backing gas (GTAW PAW, G M A W ) N/A N/A Transfer mode (GMAW) Globular Pulse Spray/Globular/Spray Visual examination of completed wel d SATISFACTORY Transverse face and root bends _j longitudinal bends U Side bends Pipe specimen, macro test for fusi o n Plate specimen, macro test for fusion Alternative Volumetric Examination R e s u l t s : NI#% Fillet weld - fracture test SATISFACTORY Length and percent of detects NONE 0 Fillet welds in plate micl Fillet welds In pipe Macro examination SATISFACTO R Y F i l l e t s i z e ( i n . ) 9/32 x 11/32 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crurnley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no Welding supervised by - Gontola Cruz We certify that the statements In t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirem e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1. Specification for Welding Procedure and Performnne' Qualification. Organization Viking Fabrication Services Date 'I/lb /vt'J Certified by }rN71. :;t• IR A Lucaa A CWI 17O7Q ILt CCI EX it Qao WELDER PERFORMANCE Welder's Name Jose Identification No. Test Description WPS Followed VFSWPS_7004 Test Coupon Production Weld Date Welded 8/28/2019 — ElSpecification & type/grade of base metal(s) A135-A795 Thickness 501 7 Variables and Qualification Umits Variables Welding Process(es) Type (i.e.; manual, semi-automatic u s e d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number cI1Ier metal or electrode specification(s) (SM) (Info. Only) Filler metal or electrode specification(s ) ( I n f o . O n l y ) Filler metal F-Number(s) Deposit thickness for each process Process 3. GMAW 3 layers min 0 Yes ED No Position(s) Vertical progression (uphill or down h i l l ) Use of backing gas (OTAW. PAW. GM A W ) Transfer mode (GMAW) Actual Values GMAW emi-Automatic Se Without SOil Pi-Pi Plthru AS.18 ER7OS.6 1/4 INCH Special Position SpE1 Both N/A Globular Pulse ige Qualified GMAW ni-Automatic ith/Without 1-2 7/8" SCH 7 P34. P41. thr 3/8 INCH Positor & Fiat for Fi Results 3 Visual examination of completed w e l d SATISFACTORY Transverse face and root bends [J Longitudinal bends U Side bends Pipe specimen, macro test for fusion t:i Plate specimen, macro test for fusion Alternative Volumetric Examination R e s u l t s N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE Fillet welds in plate IN Fillet welds in pipe Macro examination SATISFACTO R Y F i l l e t s i z e ( i n . ) 1/4 x 5/16 Concavity or convexity (in,) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no, JG1J Welding supervised by Gonzalo Cruz We certify that the statements in t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the require m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.3. $peclflcatlon for Welding Procedure and Perform a n c e Q u a h f l c o t i o n . Organization Viking Fabrication Services Date q / t4 I2DL' ...... -.-- Lucas A Cruinisy CM 17010491 ... ad . EXPflio2O. .1 WELDER PERFORMANCE QUALI F I C A T I O N ( W Welder's Name - Jose Gwterraz Identification No 3 Test Description WPS Followed VFS_WPS 1004 [J Test Coupon Production Weld Date Weld e d 8/28/2019 Specification & type/grade of base metal(s) A135 A795 Thickness SCH 10 Variables and Qualification Lim i t s Welding Process(es) Type (i.e.; manual, semi-auto m a t i c u s e d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Num b e r Filler metal or electrode specification(s) (SM) (Inf o . O n l y ) Filler metal or electrode specification(s) (i n f o , O n l y ) Filler metal F-Number(s) Deposit thickness for each proces s Process 1. GMAW 3 layers mm Yes No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GIAW, PAW, G M A W ) Transfer mode (GMAW) Actual Values GMAW Semi-Automatic Without 1.25" 504 10 PI-PI A5,18 ER70-6 F.6 1/4 INCH Special Position GMAW Semi-Automatic With/Without 1t2 7/8' SCHIO P1. thru PISE, P34, P41. thru - F.6 3/8 INCH Specta9osttion & ?t*t for FO Both N/A Pulse Spray/Globular/5 Results Visual examination of completed w e l d SATISFACTORY [] Transverse face and root bends U Longitudinal bends UI Side bends Pipe specimen macro test for fu s i o n 0 Plate specimen macro test for f u s i o n Type I Result I Type I Result I Type I Result I Alternative Volumetric Examina t i o n R e s u l t s N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE EJ Fillet welds In plate N Fillet welds in pipe Macro examination SATISFACT O R Y F i l l e t s i z e ( i n . ) 1/4 x 5/16 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no JG...LIO Welding supervised by Gonzalo Cruz we certify that the statements In t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the require m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 62.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date /j a;LucasACntnleY :- cwl..17o!o491,: WELDER PERFORMANCE QUA L I F I C A T I O N W P Q Welder's Name lose Guiterrez identification No. I Test Description WPS Followed VFS WPS 7002 Test Coupon Production Weld Date Welded 8/28/2019 Specification & type/grade of base me t a l ( s ) A135/A795 Thickness SCH 10 Testing Variables and Qualificati o n l i m i t s Welding Variables (QW 350) Actual Values Range Qualified Welding Process(es) Type (i.e.; manual, semi-automa t i c used) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification( s ) ( S P A ) ( I n f o . O n l y ) Filler metal or electrode specification(s) (info. Only) Filler metal F-Number(s) Deposit thickness for each proc e s s Process 1 GMAW 3 layers min El Yes MX Position(s) Vertical progression (uphill or do w n h i l l ) Use of backing gas (GTAW, PAW , G M A W ) Transfer mode (GMAW) GMAW GMAW Semi-Automatic Semi Automatic Without With/Without 4" 2 7/8u UT SCHIO SCHIG Pi-Pi Pt thru P15F, P54, P41thruP49 AS.18 ER70S-6 F.6 F.6 No 1/4 INCH 6 3/8 INCH Special Position special Pnition & fiat tar cllith Both Both N/A N/A Globular Pulse Spray/Globular/Spral - - Visual examination of completed weld SATISFACTORY [] Transverse face and root bends (J Longitudinal bends LJ Side bends Pipe specimen, macro test for fusi o n 0 Plate specimen, macro tes t f o r f u s i o n Qj Result Alternative Volumetric Exami n ation Results N/A Fillet weld- fracture test SATISFACTORY Length and percent of defects. NONE EJ Fillet welds In plate LN Fillet welds in pipe Macro examination SATISFACT O R Y F i l l e t s i z e ( i n . ) 5/16 x 318 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. iG_4,10 Welding supervised by .Gonzola Crux We certify that the statements I n t h i s r e c o r d a r e c o r r e c t a n d t h a t the test coupons were prepared, welded, and tested in accordance with the require m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date 9.1 6 Lucss A Cnmle &*WS, c'! WELDER PERF O R M A N C E Q U A iFIcATLON (WPQ Weider5s Name Jose Guiterrez - Identification No J Test Description WPS Followed - VFSWPS_7004 Test Coupon l inj Production Weld Date Welde d 8/28/2019 Specification & type/grade of base metal(s) A135-A795 Thickness 504 40 Variables and Qualification thni t s Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automa t i c u s e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 1.2Sf' 1'-2 7/8* Base Metal Thickness 504 40 $01 40 Base metal P-Number to P-Nu m b e r PI-Pi PS thfll P15F, 934, P41 thru P49 Filler metal or electro(je specification(s) (SFA) (Info. Only) A518 Filler metal or electrode specifica t i o n ( s ) ( I n t o . O n l y ) ER70S-6 Filler metal F-Numberjs) F.6 F.6 Deposit thickness for each proc e s s Process 1 GMAW 3 layers minOYes El No 1/4 INCH S 3/8 INCH Position(s) Special Position Spec$% Position S 51st for SWats Vertical progression (uphill or d o w n h i l l ) Both Both Use of backing gas (GIAW, PA WS GMAW) N/A N/A Transfer mode (GMAW) Globular Pulse Spray/Globular/Spray Results . I Visual examination of complete d w e l d SATISFACTORY - Transverse face and root bends U Longitudinal bends (J Side bends Pipe specimen, macro test for f u s i o n U Plate specimen, macro te s t f o r f u s i o n Alternative Volumetric Examinatio n Results Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE Fillet welds in plate N Fillet welds In pipe Macro examination SATISFACT O R Y F i l l e t s i z e ( i n . ) Sf16 x 5116 - Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. JGj_40 Welding supervised by Gonzalo Cruz We certify that the statements In t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requir e m e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Pro c e d u r e a n d P e r f o r m a n c e Q u a l i f i c a t i o n . Date Organization iucasACrwntey. .CW1 17070491' OC1. ExP.niro Fabrication Services Actual Values GMAW SemlAutomatic Without 4" SCH 40 Pi-Pi AS.18 ER7OS-6 F.6 1/4 INCH Special Position Both GMAW Semi-Automatic With/Without 27/8"-UT SCH 40 Pt thru P15F, P34, P4t tliru P49 F.6 - 13/8 INCH Spedl Poutton & Flat tar rtttt Both Globular I Pulse Spray/Globular/Spray WELDER PERFORMANCE QUALIFICAT I O N ( W P C Welder's Name Jose Guiterrez Identification No. J Test Description WPS Followed VFS_WPS_7002 Test Coupon Z Production Weld D a t e W e l d e d 8128/2019 Specification & type/grade of base metal(s ) A53 Thickness - SCH 40 Variables and Qualification limits Variables Welding Process(es) Type (i.e.; manual, semi-automatic u s e d ) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA ) ( i n f o . O n l y ) Filler metal or electrode secIfication() (info, Only) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 Layers min 0Yes [] No Position(s) Vertical progression (uphill or downh i l l ) Use of backing gas (GTAW, PAW, GMA W ) Transfer mode (GMAW) Results Visual examination of completed weld SATISFACTORY EJ Transverse face and root bends Lj Longitudinal bends U Side bends Pipe specimen, macro test for fusion D Plate specimen, macro test for fusion Type Result Type Result - Type Result - - - --. Alternative vojumetnc txamrnauon t e s u ; t s ; -' Fillet weld - fracture test SATISFACTORY Length and percent of defects - NONE 0 Fillet welds In plate W Fillet welds in pipe Macro examination SATISFACTOR Y F i l l e t s i z e ( I n . ) 9132 x 11/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. iG4,,40 Welding supervised by Gonzola Cruz We certify that the statements In th i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requireme n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure a n d P e r f o r m a n c e Q u a l i f i c a t i o n . Date cVI Organization I,. Lucas A CnmIey': ..c1 -i7o7o4s1 -•• Viking Fabrication Services Z— WELDER PERFORMANCE QUALIFICATION ( W P Q Welder's Name Robert Carrillo Identification No. R Test Description WPS Followed VFS WPS 3004 M Test Coupon lV'Production Weld Date Welded 7/2/2019 Specification & type/grade of base metal(s) A135-A795 Thickness SCH 7 Testing Variables and Qualification Umi t s Welding Variables (QW-350) Actual Values Range qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 1.2S " " 12 7/8 Base Metal Thickness SO-I 7 SCH 7 Base metal P-Number to P-Number PI-PI Pt thru P15F, P34, P41 thru P49 Filler metal or electrode specification(s) (SEA) (info. O n l y ) AS, 18 Filler metal or electrode specification(s) (Info. Only) ER70S-6 Filler metal F-Number(s) F.6 F.6 Deposit thickness for each process Process 1 GMAW 3 layers mm Yes nX No 1/4 INCH S 3/8 INCH Position(s) Special Position Special Position S flat for PtiQts Vertical progression (uphill or downhill) Both Both Use of backing gas (GTAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Short Circuit Shcrt ctrcult Visual examination of completed weld SATISFACTORY Transverse face and root bends Lj Longitudinal bands UI Side bends Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Res u l t s ; N/A - Fillet weld fracture test SATISFACTORY Length and percent of defects NONE Fillet welds in plate Fillet welds in pipe Macro examination SATISFACTORY Fill e t s i z e ( I n . ) 7/32 x 7/32 Concavity or convexity (in.) - Other Tests Film or specimens evaluated by - Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RCI Welding supervised by GonzaloCruz We certify that the statements In this reco r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested In accordance with the requirements o f S e c t i o n l x o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and P e r f o r m a n c e Q u a l i f i c a t i o n . Organization Viking Fabrication Services Date (/ f''i Certified by .. 1• I .i.lI .UAfl '-• .• .•, .. .-,. P .ucaiu it CrnIey :•.' CtVP O1Cj5% ........ '•: :.-•... k-_*P .!/1/Q •' :. WELDER PERFORMANCE QUALIFICATION ( W P Q ) Welder's Name Robert Carrillo Identification No. R - Test Description WPS Followed VFSWPS 3002 Test Coupon ZProduction Weld Date W e l d e d 7/2/201.9 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 7 Testing Variables and Qualification Limits Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW - GMAW Type (i.e.; manual, semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 4 2 7/8' UT Base Metal Thickness SCI4 7 SQ4 7 Base metal P-Number to P-Number P1-Pi P1 thru PISF, P34. P41 thru P49 Filler metal or electrode specification(s) (SFA) (Inf o . O n l y ) A5.18 Filler metal or electrode spei1ication(s) (Into. Only ) ERJOS& Filler metal F-Number(s) F6 Deposit thickness for each process Process 1. GMAW 3 layers min M Yes MX No 1J4 INCH 4 3/8 INCH Position(s) Special Position sped Poivan & rt fat Vertical progression (uphill or downhill) both Both Use of backing gas (GTAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Short Circuit Short C1rcut I Results Visual examination of completed weld SATISFACTORY D Transverse face and root bends Li Longitudinal bends LJ Side bends 104N Pipe specimen, macro test for fusion 0 Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Resul t s N/A Fillet weld - fracture test SATISFACTORY Length and percent of defects NONE 0 Fillet welds In plate Fillet welds in pipe Macro examination SATISFACTORY Fillet s i z e ( i n . ) 5/16 x 9/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC4,1 Welding supervised by Gonzota Cruz We certify that the statements in this rec o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Perfo r m a n c e Q u a l i f i c a t i o n . Organization Viking Fabrication Services Date /Z Certifipd r_-.•--- - (-.- AucasAC, CWI 1701 \Clot EXP J . WELDER PERFORMANCE QUALIFI C A T I O N ( W P Q ) Welder's Name Robert Carrillo Identification No. Test Description WPS Followed \IFSWPS3004 Test Coupon Production Weld Date Welded 7/2/2019 - Specification & type/grade of base me t a l ( s ) A135-A795 Thickness SCH 10 Variables and Qualification Limits Weldln& Variables Welding Process(es) Type (i.e,; manual, semi-automatic used) Backing (with/without) Plate Pipe (enter diameter) X Base Metal Thickness Base metal PN umber to P-Num b e r Filler metal or electrode specification(s) (SFA) (Info. Only) Filler metal or electrode specification(s) (i n f o . O n l y ) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 layers min M Yes MXNo Position(s) Vertical progression (uphill or downh i l l ) Use of backing gas (GTAW, PAW, G M A W ) Transfer mode (GMAW) Actual Values GMAW erniAutomatIc Without 3.25" SCH 10 P14'l AS18 ER7OS-6 F.6 3./4 INCH Special Positto' Both N/A Short Circuit GMAW Semi-Automatic - With/Wlthøut 1'-2 7/8 504 10 thru P3.SF, P4, P41 thru P49 F.6 ~ 3/B INCH ,pcc& PaSiUOfl & Ft4t for Fillets Both N/A Short Circuit Results Visual examination of completed w e l d SATISFACTORY Transverse face and coot bends U Longitudinal bends U Side bends Pipe specimen, macro test far fusion 11 Plate specimen, macro test for fusio n Alternative Volumetric Examination R e s u l t s : N/A Fillet weld fracture test SATISFACTORY Length and percent of defects NONE U Fillet welds in plate N Fillet welds in pipe Macro examination SATISFACTORY Fillet size (in,) 7/32 x 7/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that th e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d - tested in accordance with the requirement s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Quob'ficotion. Organization Viking Fabrication Sevicrs Date L Jiij '- :'; Luca ACrumey9 t 7C7#,o1 tw :C1 EXP. 11102 .;•.,'.. . . '':'" •'''".""':i4: WELDER PERFORMANCE QUALIFIC A T I O N ( W P Q ) Welder's Name Robert Carrillo Identification No. R Test Description WPS Followed VFS.WPSJ002 Test Coupon M,,al Production Weld Date Welded 7/2/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 10 Testing Variables and Qualification L i m i t s Welding Variables (OW-350) Actual Values Range Qualified Welding Process(es) GMAW fMAW Type (i.e.: manual, semi-automatic u s e d ) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X 4" 2 7/8" - UT Base Metal Thic - kness 501 10 SCH 10 Base metal P-Number to P-Number P1-PI. P1 thru PISF, P34. P41 thruP49 - Filler metal or electrode specification(s) (SFA) (Info. Only) AS,18 Filler metal or electr o d e s p e c i f i c a t i o n ( s ) ( i n f o . O n l y ) ER70S6 Filter metal F-Number(s) F.6 F.6 Deposit thickness for each process Process I GMAW 3 layers mi 11 n Yes El No 1/4 INCH 5 3/8 INCH Position(s) Special Position Special PoSihon & flat for flflta Vertical progression ( u p h i l l o r d o w n h i l l ) Both Both Use of backing gas (GTAW, PAW, GMAW) N/A N/A Transfer mode (GMAW) Short Circuit Short circuit Results Visual examination of completed weld SATISFACTORY EJ Transverse face and root bends U Longitudinal bands _j Side bends Pipe specimen, macr o t e s t f o r f u s i o n cJ Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examinatio n n e s u i t s ; Fillet weld - fracture test -SATISFACTORY Length and percent of defects NONE El Fillet welds in plate X Fillet welds in pipe Macro examination SATISFACT O R Y F i l l e t s i z e ( i n . ) 3/8 x 5/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC4.2 Welding supervised by Gonzola Cruz We certify that the statements in t h i s r e c o r d a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirem e n t s o f S e c t i o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Quaiification. Organization Viking Fabrication Services ', II. I ..-. ,.i ... Date a i c , }' i '.,. ,.çrtlrIeu by Liaa A C ' .CWt 1701 ;QCi. EXP, WELDER PERFORMANCE QUALIFICATION (W P c t ) Welders Name Robert Carrillo identification No R Test Description WPS Followed VFS_WPS_3004 Test Coupon Production Weld Date Welded 7/2/2019 Spadfkation & type/grade of base metal(s) A135-A795 Thickness - SCH 40 Variables and Qualification limits Variables Welding Process(es) Type (i.e; manual, semi-automatic used) Backing (with/without) Plate - Pipe (enter diameter) X Base Metal Thickness Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) (Info. O n l y ) Filler metal or electrode specification(s) (Info. Only) Filler metal F-Number(s) Deposit thickness for each process Process 1 GMAW 3 layers mm t:i Yes El No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GTAW, PAW, GMAW) Transfer mode (GMAW) Actual Values Range Qualified MAW GMAW Semi-Automatic Semi-Automatic Without With/Without 125' 1"-2 7/8" SCH 40 P1-Pt Pt thru P1SF P34, P41 thru P49 AS.18 ER7OS-6 F.6 F.6 1/4 INCH 5 3/8 INCH Special Position Special Position & flat fur Fillet Both Both N/A N/A Short Circuit Short circuit r Results Visual examination of completed weld SATISFACTORY D Transverse face and root bends LJ Longitudinal bends J Side bends Pipe specimen, macro test for fusion El Plate specimens macro test for fusion Type I Result I Type I Result I Type I Result Alternative Volumetric Examination Results: Fillet weld -fracture test SATISFACTORY Length and percent of defects NONE D Fillet welds in plate tN Fillet welds in pipe Macro examination SATISFACTORY Fillet size (in.) 1/3 x 1/3 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RC3 Welding supervised by Gonzalo Crux We certify that the statements in this record a r e c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Secti o n I X o f t h e A S M E B O I L E R A N D P R E S S U R E V E S S E L C O D E & A W S 811 Specification for Welding Procedure and Performance Qualification Organization Viking Fabrication Services Date /-rjc.l certified by Luca A Crumló IN*' r1prX CM 170104V* EXP, 1/1f WELDER PERFORMANCE CtUALIFICATION (WPQ) Welder's Name Robert Carrillo Identification No. Test Description WPS Followed VFSWPS 3002 Test Coupon UN Production Weld Date Welded 7/22/2019 Specification & type/grade of base metal(s) A135/A795 - Thickness SO-I 40 Testing Variables and Qualification Limits Welding Variables (QW-350) Actual Values Range Qualified Welding Process(es) GMAW GMAW Type (i.e.; manual, semi-automatic used) Semi-Automatic Semi-Automatic Backing (with/without) Without With/Without Plate Pipe (enter diameter) X - 4" 2 718" UT Base Metal Thickness _SCH 40 SCH 40 Base metal P-Number to P-Number Filler metal or electrode specification(s) (SFA) (info. O n l y ) Filter metal or electrode specification(s) (info. Only) Filler metal F-Number(s) Deposit thickness for each process Process GMAW 3layersmin M Yes MX No Position(s) Vertical progression (uphill or downhill) Use of backing gas (GTAW, PAW, GMAW) Transfer mode (GMAW) P1-P1 - PS thru P15F, P34, P41 thru P49 AS.18 ER70S-6 F.6 FA ______________________ _ 1/4 INCH 53/8INCH Special Position W_131 Position & Fl for Fiets Both Both N/A WA Short Circuit Short Circuit Results Visual examination of completed weld SATISFACTORY Transverse face and root bends Lj Longitudinal bends ,,_j Side bends Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination ReSult5 NfA Fillet weld fracture test SATISFACTORY Length and percent of defects NONE 11 Fillet welds In plate Fillet welds in pipe Macro examination SATISFACTORY Fillet size (In.) 5/16 x 3/8 Concavity or convexity (in.) Other Tests - Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services - Mechanical Tests conducted by Lucas Crumley Laboratory test no. - RC4.3 Welding supervised by Gonzola Cruz - We certify that the statements in this record are c o r r e c t a n d t h a t t h e t e s t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Sectio n IX of the ASME BOILER AND PRESSURE VESSEL CODE & A W S B2,1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date •)/ç: /4ce ________________ _ _ Certified by -'----'"- -.------- '. cv CWI •1707 r •.. ct EXP. I. WELDING OPERATOR PERFORMANCE QUAUFICATION (WPQ) Welder's Name Seqouia Stueve Identification No. S Sample Number - S_A1_7 Test Description WPS Followed VFS.,,WPS_1001 U Test Coupon jJ Production Weld Date Welded 12/5/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 7 Base Metal P-Number 1 to P-Number 1. Position(s) S.P. Pipe Schedule: 7 Pipe Diameter: 1.25" Outlet Diameter: 0.5" Filler metal (SFA) specification AS.18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Umits When Using Machine Welding Equipment I Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF - Position(s) S.P. S.P,, F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends [_J Longitudinal bends _j Side bends 0 Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld -fracture test N/A Length and percent of defects Fillet welds in plate Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 1/8 x 7/32 Concavity or convexity (In.) Other Tests Film or specimens evaluated by Lucas Crurnley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. S_Al_i Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons w e r e p r e p a r e d , w e l d e d a n d tested In accordance with the requirements of Section IX of the ASME BOILER AND PRESSU R E V E S S E L C O D E & A W S 82,1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date j /'/74z.7 Certified by Lucas A Crumley cw 17070491 OCI EXP. 7/112020 WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Seqoula Stueve Identification No. S Sample Number S,A1_10 Test Descri WPS Followed VFSWPS1001 ljTest Coupon 1J Production Weld Date Welded - 12/5/2019 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 10 Base Metal P-Number 1 to P-Number 1 Position(s) Si. Pipe Schedule: 10 Pipe Diameter: 1.25" Outlet Diameter: 0.5" Filler metal (SFA) specification - A5.18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Welding E q u i p m e n t Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side NAP GMAW DIRECT OFF S.P. WITH SINGLE NAP! VFLEX GMAW DIRECT OFF S.P., F. WITH OR WITHOUT SINGLE Results I Visual examination of completed weld Satisfactory Transverse face and root bends H Longitudinal bends U Side bends E Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result - Type Result Type Result Alternative Volumetric Examination R e s u l t s Fillet weld - fracture test N/A Length and percent of defects D Fillet welds in plate EX Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 1/8 x 5/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no. SA110 Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER A N D P R E S S U R E V E S S E L C O D E & A W S 82.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date Certified by Lucas A Crumley \ $ CWI 17070491 '•'. !!: 1 : : 4r 17 WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Segouia Stueve - Identification No. S Sample Number S_A140 Test DescriDtion WPS Followed VFS...WPS1001 LJ Test Coupon I XJ Production Weld Date Welded 12/5/2019 Specification & type/grade of base metal(s) - A135/A795 Thickness SCH 40 Base Metal P-Number 1 to P-Number 1 Position(s) S.P. Pioe Schedule: 40 Pipe Diameter: 1.25" Outlet Diameter: 0.5" Filler metal (SFA) specification AS.18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Weldi n g E q u i p m e n t 1 Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. S.P., F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results I Visual examination of completed weld Satisfactory Transverse face and root bends Li Longitudinal bends Side bends Pipe specimen, macro test for fusion n Plate specimen, macro test for fusion Type Result Type - Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects 11 Fillet welds In plate 1J Fillet welds in pipe Macro examination Satisfactory - Fillet size (in.) 5/32 x 5/32 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley laboratory test no. SA1_40 Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the tes t c o u p o n s w e r e p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER A N D P R E S S U R E V E S S E L C O D E & A W S B2.1 Specification for Welding Procedure and Performance Qualification , Organization Viking Fabrication Services Date /-/i.rw Certified by .4. . +. ... •'. rr4 tueas A Crtmly 4;t QCI ':?l p I WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welders Name Ramon Vazquez Identification No. V Sample Number RV1_7A Test Description WPS Followed VFS_WPS1001 Li lest Coupon Ivi Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 7 Base Metal P.Number 1. to PNumber 1 Position(s) S'P, Pipe Schedule: 7 Pipe Diameter: 1.25" Outlet Diameter: 0,5 Filler metal (SFA) specification AS.18 Filler metal or electrode classification ER70S-6 I Testing Variables and Qualification Limits When Using Machine Welding Equipment I Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. S.P., F. Backing (with or without) WITH WITH OR WITHOUT - Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends Li Longitudinal bends U Side bends 0 Pipe specimen, macro test for fusion Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects fJ Fillet welds in plate LX] Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Cruniley Laboratory test no. RVIJ_A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were p r e p a r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VE S S E L C O D E (2019 Edition) & AWS 82,1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date ' /l%' hc,o Certified by ,Lua A AWSr cWl, i i07O41 i. '\/r1 Qc1 .E)<P. F1FO3 4 .. _ • . . -: .14 .. Pipe Schedule: 7 Pipe Diameter: Filler metal (SEA) specification A5.18 3" Outlet Diameter: 1.5" ER70S6 Filler metal or electrode classification WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No. V Sample Number RV3J_A Test Descri WPS Followed VFSWPS_1001 U Test Coupon 11 v J Production Weld Date Welded 4/24/2920 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 7 Base Metal P-Number 1 to P-Number 1 Position(s) S.P. Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (QW-361.2) Actual Values I Range Qualified Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side NAP NAP/VFLEX GMAW GMAW DIRECT DIRECT OFF OFF S.P. S.P., F. WITH WITH OR WITHOUT SINGLE SINGLE Results Visual examination of completed weld Satisfactory LIII Transverse face and root bends U Longitudinal bends tj Side bends LI Pipe specimen, macro test for fusion LI Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects LI Fillet welds in plate lJ Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/15 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RV3,7,,A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepa r e d , w e l d e d , a n d tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CO D E (2019 Edition) & AWS 82,1 Specification for Welding Procedure and Performance Qua1efcatian. Organization Viking Fabrication Services Date c/l4112 Certified by A,Cruriy . .Aws :;.CN .17O7Q4i ': QCt E?P7/i/2O2c WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welders Name Ramon Vazquez Identification No V Sample Number RV110A Test Description WPS Followed VFSWPS 1001 [J Test Coupon [J Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 10 Base Metal P Number 1 to P Number 1 Position(s) SIP. Pipe Schedule 10 Pipe Diameter 1.25" Outlet Diameter 0.51, Filler metal (SIA) specification AS 18 Filler metal or electrode classification ER70S 6 Testing Variables and Qualification Limits When Using Machine Welding Equipment I Welding Variables (OW 361 2) Actual Values Range Qualified Type of Welding (Machine) NAP NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S P SIP,, F Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory Transverse face and root bends L] Longitudinal bends Lj Side bends LII Pipe specimen, macro test for fusion J Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects 'LI Fillet welds in plate 1 Xj Fillet welds In pipe Macro examination Satisfactory Fillet size (in,) 3/16 x 3/16 Concavity or convexity (in) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas crumley Laboratory test no. RV1_10_A Welding supervised by GonzalO Cruz We certify that the statements in this record are correct and that the test coupons were prepared, welded and tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE (2019 Edition) & AWS $2.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date 5/11110 Certified by f1tWb i4 t+C11 p+ ,Ii/23 - WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No. V Sample Number RV3J0A Test Description WPS Followed VFSWPS 1001 [J Test Coupon [J Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 10 Base Metal P-Number 1 to P-Number 1 Position(s) S.P. Pipe Schedule: 10 Pipe Diameter: 3' Outlet Diameter: 1.5" Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Using Machine Welding Equipment Welding Variables (QW-361.2) Actual Values I Range Qualified Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side NAP NAP/VELEX GMAW GMAW DIRECT DIRECT OFF OFF S.P. S.P., F. WITH WITH OR WITHOUT SINGLE SINGLE Results I Visual examination of completed weld Satisfactory Transverse face and root bends U Longitudinal bends U Side bends J Pipe specimen, macro test for fusion j Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects El Fillet welds in plate LXJ Fillet welds in pipe Macro examination Satisfactory Fillet size (in.) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no, RV310,A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepared, welded, and tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE (2019 Edition) & AWS B2.1 Specification for Welding Procedure and Performance Qualification Organization Viking Fabrication Services Date 5' Certified by -•--_-- ). A CnimIey . : .17070491 01 E.XP,:7/112023* ., 7/i /2Q23 ........& k.\ .... ,. ..,. -:• ' ' . WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No V Sample Number RV140_A Test Description WPS Followed VFSWPS 1001 U Test Coupon [5j Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) A135/A795 Thickness SCH 40 Base Metal P-Number I to P-Number Position(s) S.P. Pipe Schedule: 40 Pipe Diameter: 1.25" Outlet Diameter: 0.5" Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S-6 Testing Variables and Qualification Limits When Welding Variables (QW-361 Type of Welding (Machine) Welding Process Direct or Remote Visual Control Automatic Joint Tracking Position(s) Backing (with or without) Single or multiple passes per side rg Machine Actual Values NAP GMAW DIRECT OFF S.P. WITH SINGLE ipment Range Qualified NAP/VFLEX GMAW DIRECT OFF S,P,, F. WITH OR WITHOUT SINGLE Results Visual examination of completed weld Satisfactory El Transverse face and root bends U Longitudinal bends [j Side bends LI Pipe specimen, macro test for fusion F1Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld fracture test N/A Length and percent of defects 1:1 Fillet welds In plate J Fillet welds in pipe Macro examination Satisfactory Fillet size (in) 3/16 x 3/16 Concavity or convexity (in,) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no. RV140_A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepared, welded, and tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE (2019 Edition) & AWS B2.1 Specification for Welding Procedure and Performance Qualification. Organization Viking Fabrication Services Date slhrl~ /1-11920 Certified by J1,11 e Luoa' Crumr1 , *s CWl:'i707,O41 , .• pCt; (P,.7/iI2o23 ?- I WELDING OPERATOR PERFORMANCE QUALIFICATION (WPQ) Welder's Name Ramon Vazquez Identification No. V Sample Number RV3_40—A Test Description WPS Followed VFSWPS 1001 [J Test Coupon [j Production Weld Date Welded 4/24/2020 Specification & type/grade of base metal(s) -- A135/A795 Thickness SCH 40 Base Metal P-Number 1 to P-Number 1 Po5ition(s) S.P. Pipe Schedule: 40 Pipe Diameter: 3 Outlet Diameter: 1.5" Filler metal (SFA) specification A5.18 Filler metal or electrode classification ER70S 6 Testing Variables and Qualification Limits When Using Machine Welding Equipment I Welding Variables (QW-361.2) Actual Values Range Qualified Type of Welding (Machine) NAP - NAP/VFLEX Welding Process GMAW GMAW Direct or Remote Visual Control DIRECT DIRECT Automatic Joint Tracking OFF OFF Position(s) S.P. S.P., F. Backing (with or without) WITH WITH OR WITHOUT Single or multiple passes per side SINGLE SINGLE Results Visual examination of completed weld Satisfactory EliTransverse face and root bends L.J Longitudinal bends U Side bends Pipe specimen, macro test for fusion F I Plate specimen, macro test for fusion Type Result Type Result Type Result Alternative Volumetric Examination Results: Fillet weld - fracture test N/A Length and percent of defects El Fillet welds in plate jj Fillet welds in pipe Macro examination Satisfactory Fillet size (in,) 3/16 x 3/16 Concavity or convexity (in.) Other Tests Film or specimens evaluated by Lucas Crumley Company Viking Fabrication Services Mechanical Tests conducted by Lucas Crumley Laboratory test no, RV3,40,..A Welding supervised by Gonzalo Cruz We certify that the statements in this record are correct and that the test coupons were prepared, welded, and tested in accordance with the requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE (2019 Edition) &. AWS B2.1 Specification for Welding Procedure and Performance Qualification Organization Viking Fabrication Services Date S/2f Certified by ,- ;;.. OC1.EXP.7/1I202: . :