Loading...
HomeMy WebLinkAbout7740 EL CAMINO REAL; B; FPC2021-0046; PermitPERMIT REPORT ("pty of Carlsbad Print Date: 03/31/2022 Job Address: 7740 EL CAMINO REAL, # B, CARLSBAD, CA 92009-8514 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2161241600 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2021-0046 Status: Closed - Finaled Applied: 04/06/2021 Issued: Finaled Close Out: 03/31/2022 Inspector: Final Inspection: Project Title: Description: BEACON PHASE 2 BLDG B -PROVIDE WET PIPE AUTOMATIC FIRE SPRINKLER SYSTEM FOR EXISTING BUILDING (101 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $204.00 FIRE Reinspection (per Inspection) $212.00 Total Fees: $1,274.00 Total Payments To Date: $1,274.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov C Akj~ I TAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION HYDRAULIC CALCULATIONS BEACON BLDG. B 7740 EL CAMINO REAL CARLSBAD, CA. 92009 CONTRACT NO. 21176 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.fitanfpinc.com Page OJ-j~LNuAiN Municipal Water District Fire Flow Test Results Asset lD# WFHD3117 I I EAM# 340713 Flow Test Requested By:: Mayra Marron Telephone: 951-302-2163 Email: mmarron@titanfpinc.com Project Name:7720 El Camino Real )MWD Personnel Conducting: Mike Salazar, Bryan Rickards Date: [rime:3/8/2021 11:20am \ddress:7720 El Camino Real k ounty: San Diego Pressure Zone: Hydrant (flow) Elevation: 58feet Pipe Diameter: 8 inches Hydrant (gauge) Elevation: 63feet Pipe Diameter: 8 inches Reservoirs Involved: P.R. Stations Involved:: rsf north & south, village park, la Costa, vales 1, gardendale, southeast 2, wanket, quails Distribution System: Dead End Looped Static Pressure (prior to flow test): 167 P.S.I. Residual Pressure (during flow test): 145 P.S.I. PITOT Residual Pressure, 2 1/2 inch port: 110 P.S.l. Calculated Flow: 1 696 G.P.M. Comments: Test Results Reviewed By: MS Job Name FOR HYDRAULIC CALCULATIONS Job Location REFERENCE ONLY. INSTALLATION BY Engineer _____ OTHERS. . No Approval Representative MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. The coating on this backflow assembly uses ArrnorTekTM technol- ogy to resist corrosion due to microbial induced corrosion (MIC) or exposed metal substrate. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler sys- tems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Utilizes advanced ArmorTekTM coating technology to resist cor- rosion of internals Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4"Check Assembly No Special Tools Required for Servicing Field Replaceable Seat & Disc Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL! FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by A'MNA Standard C510. The auxiliary bypass line contains a °/&x3¼" Water Meter that complies with ANSI/AWWA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The valve body shall utilize a coating system with built-in electrochemi- cal corrosion inhibitor and microbial inhibitor. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWWA Standard C510 flow and pressure loss performance parameters. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements "The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A WATTS Brand Options - Suffix OSY: ULJFM Approved OS&Y Gate Valves [ANSI/AWWA 0515 Compliant] DNRS: Domestic Non-Rising Stem Gate Valves [ANSI/AWWA 0509 Compliant] CFM: Totalizing Cubic feet/min %"x 3/4" Water Meter [ANSI! AWWA 0700 Compliant] GPM: Totalizing Gallons/mm %"x ¼" Water Meter [ANSI! AWWA 0700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4" LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer: FDA Approved [ASME 1316.1 Class 125 & AWWA Class D Flange] Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical Joint [AWWA C111!A21.11] MJ x FL - Mechanical Joint x Flange [AWWA Cli 1!A21.11; ASME B16.1 Class 125/AWWA Class D Flange] FL x FL - Flange x Flange [ASME B16.1 Class 125 & AWWA Class D Flange] Materials Below is a general materials list of the Model LF876V All assemblies size 21/2" through 10" is similar in materials and construction. Please contact your local FEB00 Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA 0550-90 Shutoff Valves: OSY resilient wedge gate valve . (UL/FM) Check Seats Stainless Steel Disc Holder: Stainless Steel Elastorner Disc: Silicone Spring: Stainless Steel Clamp: AWWA 0606 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [F000HR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO!cUPC AWWA Standard 0510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange **Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2" - 10) - Approved by F000HR-USC, ASSE, cULus, FM, lAPM0!cUPC Vertical Up (Z-Pattern 21/2 ' - 10) - Approved by F000HR-USC, ASSE, cULus, FM, IAPMO!cUPC €, ®eFM Approved C®US 1048 864.5 Pressure - Temperature Max. Working Pressure: 175ps1 (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350p5i (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Dimensions - Weights Size: 21/211 - 10° Below are the nominal dimensions and physical weights for the Model LF876V size 21/2" through 10". Allowances must be made for normal manufacturing tolerances. Please visit our websfte to download a copy of this product's installation instructions, or contact your local FEB00 Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) M Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE DIMENSIONS WEIGHT fr in. A mm B in. mm - C in. mm D in. - mm E in. mm F in. mm - in. G mm - H in. mm in. - mm J in. mm in. mm L in. mm OSY lbs. kg. 21/2 29'/8 740 121/2 318 61/4 159 251/4 642 171/2 445 135/8 346 271/4 692 51/2 140 111/8 283 31/2 89 16% 416 111/2 292 216 98 3 291/8 740 121/2 318 61/4 159 25% 654 17% 451 141/8 359 281/4 718 51/2 140 111/8 283 33/4 95 187/8 479 111/2 292 242 110 4 311/8 791 14 356 7 178 27/4 705 18% 476 151/2 394 31 787 6 152 111/8 283 41/2 114 22% 578 13 330 347 157 6 353/4 908 16 406 8 203 32% 831 221/8 562 18/s 473 371/4 946 71/4 184 121/2 316 51/2 140 301/8 765 13 330 529 240 8 401/4 1035 181/2 470 91/4 235 1 36% 933 251A 638 201/4 527 411/2 1054 81/2 216 14 356 63/4 172 37% 959 141/2 368 827 375 10 1 461/4 11751 21 533 107A6 264 413A6 1047 281/8 714 2311A6 601 473/81202 95/8 244 1511A6 398 8 203 453/4 1162 131/8 333 1335 606 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backf low Assemblies with specified Gate Valves 8" 1F876V PS' 18 16 14 12 10 8 6 4 2 0 0 400 800 1200 1600 2000 1514 3028 4543 6057 7571 7.5 10.5 2400 qpm 9085 1pm 15.3 fps Service How Rated Flow lii Rated How 0 500 1000 1500 2000 2500 3000 3500 gpm 1892 3785 5678 7570 9463 11356 13248/pm 7.5 9.4 14.1 fps io" 1F876V PSI 10 7 6 5 4 5... 3 Service Flow Rated Flaw "UI. Rated Flaw Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. AWVVA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 Ofps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern Z- Pattern 2½" 1F876V psi Service Flow Rated Flow *UL Rated Flow 22 20 I I I 18 I I 16 I I I 14 I I 2 12 I I1( 0r__ - IT- 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350gpm 284 568 852 1136 1pm 7.5 14.7 22.0 fps Pipe Support (furnished by customer) for valve weight only. Vertical Orientation "Z-Pattern" Row Curve Z Standard Orientation"N-Pattern" Row Curve N 6' psi 1F876V Service Flow Rated Flow I I *UL Rated Flow I 18 16 I I 14 I I T-- 112 I I I I CL 2 10 I I 4 I I 2 I I I 0 I I I 0 200 400 757 600 800 1000 1200 2271 3785 7.5 11.4 1400 1600gpm 5300 1pm 17.0 fps 3" 1F876V psi Service Flow Rated How *UL Rated Flow 22 I I I I I I 20 I I I 18 I I I 1 16 I I I .3 14 I I I 5 12 I 10 I 8 I - n... 6 4 I I 2 I I I 0 0 50 100 150 200 250 300 350 400 450 500 gpm 379 757 1136 1514 1pm 7.5 14.5 22.0 fps 4" psi LF876V Service Flow I Rated Flow "UL Rated Flow I 18 16 I I I I 14 CL I I I I 1 12 8 6 -__--, 4 I I 2 I I 0 I I I I I 0 100 379 200 300 400 1136 7.5 500 600 1893 12.8 700 8009pm 2650 1pm 19.1 fps A WATTS Brand ES-F-LF876V 2015 USA: T: (800) 767-1234 • F: (800) 788-4491 • FEBcoortline.com Canada: I: (888) 208-8927 • F: (888) 479-2887 • FEBC0onhine.ca Latin America: T: (52) 55-4122-0138 • FEBC0online.com © 2019 FEBCO Hydraulic Calculations for Project Name: Drawing I Location: Drawing Name: 21176 - Beacon Phase ll_FP design_B-7740 Design Remote Area Number: 1 Calculation Date: 4/1/2021 Occupancy Classification Ordinary Group II Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm1ft2 1 500ft2 (Actual I 505ft2) 130ft2 Upright 12 0 N/A gpm at Node: N/A 250.00 at Node: 1 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 695.77 @ 122.043 Type of System: WET Volume of Dry/PreAction/Antifreeze/OtherA N/A Allowance at Source (Safety Margin = 40.725) Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: 91.354 1AM.E.P.CAD, Inc. JAutoSPRINK 2020 BETA v16.3.1.0 1 4/1/202112:07:50PM Page 1 Hydraulic Calculations for Project Name: Drawing I Location:,, Drawing Name: 21176 - Beacon Phase II_FP design_B-7740 Design Remote Area Number: Manually Flowing Remote Area Location: NA Occupancy Classification: NA Calculation Date: 4/1/2021 Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: NA NA NA Pendent 1 0 N/Agpm at Node: 250.00 at Node: N/A 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): Type of System: NA Volume of Dry/PreAction/Antifreeze/OtherA N/A Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: N/A M.E.P.CAD, Inc. rAutoSPRlNK 2020 BETA v16.3.1.0 Manually Flowii 4/1/202112:07:50PM Page 2 2800 3150 1750 2100 2450 Ftow - gpm 3500 0350 k L'iL............. I I 1. N AutoSPRINK 2020 BETA v16.3.1.0 ,© M.E.P.CAD, Inc. 4/1/2021 12:07:52PM Page 3 Job Name: Drawingi Remote Area Number: 1, Manually Flowing 200- 160 100 180 80 60 40 20 Supply Summary Sheet Node: I Static Pressure 167.000 - - —695.77 145.000 445.77 - @ 122.043 1795.77 with Hose Allowance at Source System demand curve _...lj'.J.j.j.j.j_J.IIIIIIII IIIIlIII 111111111 IIIII Ii II II II Ii I I I I I I I I I I I I I I I Hydraulic Graph N 1.85 Date: 4/1/2021 IN Summary Of Outfiowing Devices I Rnort Dcstinn & IN Job Number: 1 rin K RAI ANCIN( Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 101 96.85 40.07 11.2 74.775 i Sprinkler 108 26.00 26.00 5.6 21.556 Sprinkler 109 26.35 26.00 5.6 22.146 Sprinkler 110 26.40 26.00 5.6 22.226 Sprinkler 111 26.76 26.00 5.6 22.827 Sprinkler 112 29.02 26.00 5.6 26.861 Sprinkler 113 29.40 26.00 5.6 27.572 Sprinkler 114 30.38 26.00 5.6 29.436 Sprinkler 115 30.54 26.00 5.6 29.748 Sprinkler 116 30.77 26.00 5.6 30.198 Sprinkler 117 30.94 26.00 5.6 30.523 Sprinkler 118 30.97 26.00 5.6 30.589 Sprinkler 119 31.37 26.00 5.6 31.387 Most Demanding Sprinkler Data . © M.E.P.CAD, Inc. AutoSPRlNK 2020 BETA v16.3.1.0 4/1/2021 12:07:53PM Page 5 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 167.000 145.000 1696.00 162.768 695.77 122.043 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3-0 Supply 122.043 445.77 101 10-4 Sprinkler 74.775 96.85 108 15-8 Sprinkler 21.556 26.00 109 15-8 Sprinkler 22.146 26.35 110 15-1 Sprinkler 22.226 26.40 111 15-1 Sprinkler 22.827 26.76 112 145h/2 Sprinkler 26.861 29.02 113 145h/2 Sprinkler 27.572 29.40 114 12-8 Sprinkler 29.436 30.38 115 13-3 Sprinkler 29.748 30.54 116 12-8 Sprinkler 30.198 30.77 117 13-3 Sprinkler 30.523 30.94 118 13-101/2 Sprinkler 30.589 30.97 119 13-101/2 Sprinkler 31.387 31.37 2 4-0 121.507 8 4-0 121.385 9 4-0 121.589 10 4-0 121.634 11 4-0 121.548 .,© M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA' 4/1/2021 12:07:55PM Page 6 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 14 14-7 23.638 15 4-0 121.662 17 4-0 121.689 18 4-0 120.947 19 4-0 120.590 20 4-0 117.306 21 4-0 121.497 22 11-10 81.067 23 4-0 115.891 24 13-11Y2 28.502 25 134h/2 32.412 26 13'-3 38.632 29 4-0 121.749 34 11-0 96.468 35 13-3 39.620 37 3-5 111.769 38 15-2 23.554 39 14'-7 24.268 40 13-111/2 29.247 41 13-4% 33.248 42 12-2 31.203 43 12-9 31.530 44 12'-2 32.002 © M.E.P.CAD, Inc. 4BAutoSPRINK 2020 BETA' 4/1/2021 12:07:55PM Page 7 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 45 12-9 32.343 BR46 0-5 Gauge 114.278 411 15-2 22.935 ,© M.E.P.CAD, Inc. AutoSPRINK 2020 BETA' 4/1/2021 12:07:55PM Page 8 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as fkIQ __________________ Fitting (Foot) _________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 108 15-8 5.6 26.00 1 (See Notes) 0-6 120 21 .556 _nJ Route I Sprinkler, PO(5'-O) 5-0 0.211435 0.216 411 15-2 26.00 1.0490 5-6 1.163 411 15-2 1 1/4 91-10 120 22.935 0.044894 0.262 14 14-7 26.00 1.4420 9-10 0.441 14 14'-7 26.40 11/4 (See Notes) 13'2 120 23.638 Flow (q) from Route 3 4E(3'-81/.) 14-10% 0.164162 0.262 24 13111,4 52.40 1.4420 28'-0% 4.601 24 13111/2 29.02 11/4 9-10 120 28.502 Flow (q) from Route 5 0.371013 0.262 25 13-4% 81.42 1.4420 9-10 3.648 25 13-4% 30.97 11/4 (See Notes) 11 9 120 32.412 Flow (q) from Route 11 P0(7-5) 0.673574 0.046 26 13'-3 112.40 1.4420 9-2 6.174 26 13'3 60.93 2% 12'-5 120 38.632 Flow (q) from Route 7 0.079677 -0.000 35 13-3 173.32 2.6350 12-5 0.989 35 13-3 113.89 + 61.7 2% (See Notes) 159'2 120 39.620 Flow (q) from Route 2 and 9 4E(8'-3) 32'-111/2 0.290736 0.988 34 11-0 348.92 2.6350 192'-11/2 55.859 34 11-0 96.85 21/2 (See Notes) 8'5 120 96.468 Flow (q) from Route 13 E(8'-3), 2f(-0.000), BV(9'-7%) 17-10 0.457412 3.289 37 3'-5 445.77 2.6350 26-3 12.013 37 3-5 21/2 (See Notes) 3'0 120 111.769 BOR 0.404035 1.298 BR46 0'-5 445.77 2.7030 3'-0 1.210 BR46 0'-5 6 (See Notes) 3'5 120 114.278 E(17'-7) 17-7 0.006276 1.481 23 -3'-0 445.77 6.3570 21'-O 0.132 23 -3-0 6 (See Notes) 128111/2 150 115.891 E(11'-51/2), LtE(7'-41/2) 18'-10 0.009628 -0.008 20 -3-0 445.77 5.3490 147'-9Y2 1.423 (, © M.E.P.CAD, Inc. A41 AutoSPRINK 2020 BETA v16.3.1.0 1, Manually Flowing 4/1/2021 12:07:57PM Page 9 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as n npp.thrn uI.ia Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 20 4-0 6 (See Notes) 84 120 117.306 2GV(0'-O), 2T(0'-O), BFP(-3.48 0), LtE(11'4) 11'-4 0.006276 19 4-0 445.77 6.3570 19'-8 3.284 19 4-0 6 (See Notes) 24'0 140 120.590 P0(47-3%) 4731/2 0.005007 -0.000 18 4-0 445.77 6.2800 7131/2 0.357 18 4-0 8 (See Notes) 108'21/2 150 120.947 EE(4'-9Y2) 491/ 0.003878 8 4-0 445.77 6.4470 113-0% 0.438 8 4-0 8 (See Notes) 9'-10 150 121.385 T(18-8%) 18'-8Y2 0.003878 0.001 21 4-0 445.77 6.4470 28'-6 0.111 21 4-0 10 (See Notes) 196-5 150 121.497 EE(8'-3) 8-3 0.000456 -0.001 9 -3'-0 306.43 8.6780 204'-8 0.093 9 -3'-O 10 97-9% 150 121.589 0.000456 10 4-0 306.43 8.6780 97-9% 0.045 10 4-0 10 (See Notes) 54'l 150 121.634 EE(8'-3) 8-3 0.000456 15 -3-0 306.43 8.6780 62'-4 0.028 15 4-0 10 (See Notes) 2291/2 150 121.662 T(37-6) 37-6 0.000456 17 4-0 306.43 8.6780 60'-3Y2 0.027 17 4-0 8 (See Notes) 16361/2 150 121.689 5, T(18-8%) 18-8% 0.001939 1 4-0 306.43 6.4470 182-3 0.353 250.00 122.043 Hose Allowance At Source Total(Pt) Route 1 1 695.77 109 15-8 5.6 26.35 1 (See Notes) 0-6 120 22.146 ''Route 2' Sprinkler, P0(5-0) 5'-0 0.216778 0.216 38 15-2 26.35 1.0490 5-6 1.192 (,©M.E.P.CAD, Inc. M AutoSPRlNK2O2OB ETA v16.3.1.0 1, Manually Flowing 4/1/2021 12:07:57PM Page 10 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting!Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as , nppptit,p nI..o Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 38 15-2 w 9-10 120 23.554 0.046029 0.262 39 14-7 26.35 1.4420 9'-lO 0.453 39 14-7 26.76 V/4 (See Notes) 132 120 24.268 (q) from Route 4 4E(3'-81,4) 0.168284 114'-101/. Flow 0.262 40 13'-11Y2 53.11 1.4420 2801/2 4.717 40 13'-111/2 29.40 1 9-10 120 29.247 Flow (q) from Route 6 0.380242 0.262 41 13'-4Y2 82.51 1.4420 9-10 3.739 41 13'-4% 31.37 1% (See Notes) 11-9 120 33.248 Flow (q) from Route 12 P0(7-5) 0.690186 0.046 35 13-3 113.89 1.4420 9-2 6.326 39.620 Total(Pt) Route 2 110 15-1 5.6 26.40 1 (See Notes) 0-6 120 22.226 ••••Route 3••''' Sprinkler, P0(5-0) 5-0 0.217509 0.216 14 14-7 26.40 1.0490 5-6 1.196 23.638 Total(Pt) Route 3 111 15,-i 5.6 26.76 1 (See Notes) 0-6 120 22.827 •••••Route4'''•' Sprinkler, P0(5-0) 5-0 0.222936 0.216 39 14-7 26.76 1.0490 5-6 1.226 24.268 Total(Pt) Route 4 112 i451,4 5.6 29.02 1 (See Notes) 0'-6 120 26.861 '''' Route 5 Sprinkler, P0(5-0) 5,-0 0.259156 0.216 24 13'-11Y2 29.02 1.0490 5-6 1.425 28.502 Total(Pt) Route 5 113 i45h/2 5.6 29.40 1 (See Notes) 0-6 1 120 27.572 •••••Route6".'. Sprinkler, PO(5'-O) 5,-0 0.265492 0.216 40 13ii1/2 29.40 1.0490 5'-6 1.460 29.247 Total(Pt) Route 6 114 12-8 5.6 30.38 1 (See Notes) 0-6 T 120 29.436 J •''•'Route7••••• Sprinkler, I PO(5'-U) 5-0 0.282058 0.216 42 12-2 30.38 1.0490 5'-6 1.551 &@ M.E.P.CAD, Inc. AutoSPRINK 2020 BETA v16.3. 1.0 1 Manually Flowing 4/1/2021 12:07:57PM Page 11 Job Name: Drawing I Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as , nag.tiva wII.o Fitting (F oot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) 42 12-2 1',' 9'-10 120 31.203 0.059890 -0.262 43 12-9 30.38 1.4420 9-10 0.589 43 17-9 30.54 '11/4 (See Notes) 1l'5 120 31.530 Flow (q) from Route 8 4E(3-81,4), P0(7-5) 22-31/2 0.216961 -0.216 26 13-3 60.93 1.4420 33-8% 7.318 38.632 Total(Pt) Route 7 115 13-3 5.6 30.54 1 (See Notes) 06 120 29.748 'S... Route 8'..'' Sprinkler, P0(5-0) 5-0 0.284823 0.216 43 12-9 30.54 1.0490 5-6 1.566 31.530 Total(Pt) Route 8 116 12-8 5.6 30.77 1 (See Notes) 0'6 120 30.198 '''''Route 9''''' Sprinkler, PO(5'-O) 5-0 0.288804 0.216 44 12-2 30.77 1.0490 5-6 1.588 44 12-2 . 9'-10 120 32.002 0.061322 -0.262 45 12'-9 30.77 1.4420 9'-lO 0.603 45 17-9 30.94 11/4 (See Notes) 11-5 120 32.343 Flow (q) from Route 10 4E(3'-8%), P0(7-5) 22 31,4 0.222168 -0.216 35 13-3 61.71 1.4420 33'- 81/2 7.493 39.620 Total(Pt) Route 9 117 13-3 5.6 30.94 1 (See Notes) 0'-6 120 30.523 '''''Route 10''''' Sprinkler, PO(5'-O) I 0.291682 0.216 45 12-9 30.94 1.0490 5-6 1.604 32.343 Total(Pt) Route 10 118 1310% 5.6 30.97 1 (See Notes) 0'-6 120 30.589 ''''Route ll''''' Sprinkler, P0(5-0) 5'-0 0.292262 0.216 25 13-4% 30.97 1.0490 5-6 1.607 32.412 Total(Pt) Route 11 119 13-10% 5.6 31.37 1 (See Notes) 0-6 120 31.387 '''''Route 12''''' Sprinkler, P0(5-0) 5-0 0.299305 0.216 41 13-41/2 31.37 1.0490 5'-6 1.646 33.248 Total(Pt) Route 12 f,©M.E.P.CAD, Inc. AutoSPRlNK2020BETA06.3.1.0 1, Manually Flowing 4/1/2021 12:07:57PM Page 12 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Pipe Information Node I Elevi (Foot) K-Factor Flow added this step (q) Nominal ID Fittings& Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as . nognfiva AgaLUG Fitting (Foot) _________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 101 10-4 11.2 96.85 1% (See Notes) 1'-111/2 120 74.775 ••'•' Route 13••••• Sprinkler, E(3'-O), P0(6-0) 9-0 0.633459 -0.652 22 111-10 96.85 1.3800 10'-111/2 6.944 22 11'-10 2 (See Notes) 171101/2 120 81.067 C(12'-3Y2), 2E(6'-2), P0(12-3 1/2) 36-11 0.071958 0.375 34 11-0 96.85 2.1570 208-10 15.026 96.468 Total(Pt) Route 137::] 21 3'O 306.43 10 85-1 150 121.497 '••• Route 14•••'' Flow (q) from Route 1 0.000106 0.002 2 -3'-0 139.34 8.6780 85-1 0.009 2 -3'-O 10 (See Notes) 343'31/2 150 121.507 T(37'-6) 37-6 0.000106 11 -3'-0 139.34 8.6780 380-91/2 0.040 11 -3-0 8 (See Notes) 432'71/2 150 121.548 1(18-8%) 18-8% 0.000451 -0.003 29 -3-0 139.34 6.4470 451-31/2 0.204 29 -3-0 8 (See Notes) 651'91/2 150 121.749 5 0.000451 0.000 I -3-0 139.34"6.4470 65191/2 0.294 122.043 Total(Pt) Route 14 ,©M.EP.CAD, Inc. §lAutoSPRINK 2020 BETA 06.3.1.0 1, Manually Flowing 4/1/2021 12:07:57PM Page 13 Job Name: Drawingi Remote Area Number: 1, Manually Flowing Date: 4/1/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) I IC Value Multiplier • / Actual Inside Diameter .. 4 Factor .87 Value Of C 100 130 140 150 = Schedule 40 Steel Pipe Inside Diameterj Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 221A° Elbow f Flow Device fd Flex Drop FDC Fire Department Connecti fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,© M.E.P.CAD, Inc. M AutoSPRlNK 2020 BETA v16.3.1.0 1, Manually Flowing 4/1/2021 12:07:57PM Page 14 Hydraulic Calculations for Project Name: Drawingi Location:,, Drawing Name: 21176 - Beacon Phase lI_FP design_B-7740 Design Remote Area Number: I Calculation Date: 4/1/2021 Occupancy Classification Light Hazard Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.logpm/ft2 I 500ft2 (Actual 1006ft2) 1 54ft2 Pendent 7 0 N/Agpm at Node: N/A 100.00 at Node: I Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 433.74 @ 125.264 Type of System: WET Volume of Dry/PreAction/Antifreeze/OtherA N/A Allowance at Source (Safety Margin = 39.971) Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: N/A ©M.E.P.CAD, Inc. JAutoSPRINK 2020 BETA v16.3.1.0 1 4/1/202112:06:27PM Page 1 3500 2800 3150 1400 2100 1750 2450 Flow - gpm ,© M.E.P.CAD, Inc. 11 AutoSPRINK 2020 BETA 06.3.1.0 4/1/2021 12:06:28PM Paqe 2 120 a- Job Name: Drawingi Remote Area Number: 1 200- 100 160 18C 20 80 Supply [Summary Sheet Node: I - Static Pressure 167.000 4374 1.235 .496.00 @ 145.000 - 333.74@ _433.74 125.264 with Hose Allowance at Source_._ System demand curve ._.•IJ •I.I.J.I.1.l.1.1IIIIIII( 111111111 111111111 111(11111 11111111 III liii II I I I I I I I I I Hydraulic Graph N 1.85 Date: 4/1/2021 4Isummary Of Outfiowing Devices I Job Number: 1 Report Description: CEILING& IN RACK BALANCING Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) c Sprinkler 101 40.07 40.07 11.2 12.800 Sprinkler 102 40.43 15.40 11.2 13.033 Sprinkler 103 41.70 15.40 11.2 13.863 Sprinkler 104 44.37 15.40 11.2 15.696 Sprinkler 105 48.72 15.40 11.2 18.919 Sprinkler 106 54.99 15.40 11.2 24.108 Most Demanding Sprinkler Data © M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA v16.3.1.0 4/1/2021 12:06:30PM Page 4 Job Name: Drawingi Remote Area Number: I Date: 4/1/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 167.000 145.000 1696.00 165.235 433.74 125.264 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 4-0 Supply 125.264 333.74 101 10-4 Sprinkler 12.800 40.07 102 10-4 Sprinkler 13.033 40.43 103 10-4 Sprinkler 13.863 41.70 104 10'-4 Sprinkler 15.696 44.37 105 10'-4 Sprinkler 18.919 48.72 106 10'-4 Sprinkler 24.108 54.99 107 10-4 Sprinkler 32.098 63.45 2 4-0 124.952 8 4-0 124.879 9 4-0 124.998 10 4-0 125.024 11 4-0 124.975 15 4-0 125.041 17 4-0 125.057 18 4-0 124.622 19 4-0 124.413 20 4-0 121.023 21 4-0 124.945 ,© M.E.P.CAD, Inc. IAAutoSPRINK 2020 BETA' 4/1/2021 12:06:32PM Page 5 Job Name: Drawingi Remote Area Number: I Date: 4/1/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 22 11-10 13.505 23 4-0 120.198 27 11-10 13.761 28 11-10 14.672 29 4-0 125.092 30 11-10 16.682 31 11-10 20.215 32 11-10 25.893 33 11-10 34.621 34 11-0 106.312 37 3-5 116.632 BR46 0-5 Gauge 118.639 ,© M.E.P.CAD, Inc. iflAutoSPRINK 2020 BETA 4/1/2021 12:06:32PM Page 6 Job Name: Drawingi Remote Area Number Date: 4/1/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as , npj,tiup mu..______ ____________ Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 101 10-4 11.2 40.07 1% (See Notes) 1111/2 120 12.800 'Route1 ot Sprinkler, E(3'-O), P0(6-0) 91-0 0.123784 -0.652 22 11-10 40.07 1.3800 10'- 111/2 1.357 22 111-10 2 18-2 120 13.505 0.014061 27 11-10 40.07 2.1570 18'-2 0.255 27 11'-10 40.43 2 17'-10 120 76110 13. Flow (q) from Route 2 0.051116 28 11-10 80.50 2.1570 17-10 0.912 28 11-10 41.70 2 18'-2 120 14.672 Flow (q) from Route 3 0.110641 30 11'-10 122.20 2.1570 18'-2 2.010 30 11-10 44.37 2 18'- 120 682O 16. Flow (q) from Route 4 0.196241 31 11-10 166.58 2.1570 18-0 3.532 31 11-10 48.72 2 18-0 120 20.215 Flow (q) from Route 0.315432 32 11-10 215.29 2.1570 1 8-0 5.678 32 111 10 54.99 2 18-2 120 25. 893 Flow (q) from Route 6 0.480475 33 11-10 270.28 2.1570 18'-2 8.729 33 11-10 63.45 2 (See Notes) 63'6V2 120 34.621 Flow (q) from Route 7 C(12'-3%), 2E(6'-2), P0(12-3 1/) 36-11 0.709746 0.375 34 11-0 333.74 2.1570 100-6 71.315 34 11-0 21/2 (See Notes) 8'5 120 106.312 E(8'-3), 2f(-0.000), BV(9'-71/2) 17'-10 0.267764 3.289 37 3-5 333.74 2.6350 26-3 7.032 37 3-5 21,6 (See Notes) 3'-0 120 116.632 BOR 0.236517 1.298 BR46 0-5 333.74 2.7030 3-0 0.708 BR46 0-5 6 (See Notes) 3'5 120 118.639 E(17'-7) 17-7 0.003674 1.481 23 -3-0 333.74 6.3570 21-0 0.077 © M.E.P.CAD, Inc. 411 AutoSPRINK 2020 BETA v16.3.1.0 1 4/1/2021 12:06:34PM Page 7 'Job Name: Drawingi - Remote Area Number: Date: 4/1/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nnpti..Ia iiIi.a Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 23 -3-0 6 (See Notes) 128111/2 150 120.198 E(11'-51/,), LtE(7-41/z) 18-10 0.005636 -0.008 20 -3-0 333.74 5.3490 147-9Y2 0.833 20 -3-0 6 (See Notes) 8'4 120 121.023 2GV(0'-O), 2T(0'-O), BFP(-3.48 0), LtE(11'-4) 11-4 0.003674 19 -3-0 333.74 6.3570 19-8 3.390 19 -3-0 6 (See Notes) 24'0 140 124.413 P0(47-31/2) 4731/ 0.002931 -0.000 18 -3-0 333.74 6.2800 71-31/2 0.209 18 4-0 8 (See Notes) 10821/2 150 124.622 EE(4-9Y2) 0.002270 8 4-0 333.74 6.4470 F113-01/2 0.257 8 4-0 8 (See Notes) 91 10 150 124.879 T(18'-81/2) 1881,4 ---] 0.002270 0.001 21 -3-0 333.74 6.4470 28-6 0.065 21 4-0 10 (See Notes) 196'5 150 124.945 EE(8-3) 8-3 0.000267 -0.001 9 4-0 229.42 8.6780 204-8 0.055 9 4-0 10 9791,/2 150 124.998 0.000267 10 4-0 229.42 8.6780 97'-9% 0.026 10 -3'-0 10 (See Notes) 54'l 150 125.024 EE(8-3) 8-3 0.000267 15 -3-0 229.42 8.6780 62-4 0.017 15 4-0 10 (See Notes) 229h/2 150 125.041 T(37'-6) 37'-6 0.000267 17 -3-0 229.42 8.6780 60'-31/2 0.016 17 4-0 8 (See Notes) 163'6% 150 125.057 5, T(18-81/2) 18'-81/2 0.001135 ______________ 1 -3'-O 229.42 6.4470 182-3 0.207 100.00 125.264 Hose Allowance At Source Total(Pt) Route 1 1 433.74 &@ M.E.P.CAD, Inc. AutoSPRINK 2020 BETA v16.3.1.0 1 4/1/2021 12:06:34PM Page 8, Job Name: Drawing 1 Remote Area Number: Date: 4/1/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Loss Per Unit Pt Friction (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 102 10-4 11.2 40.43 1% (See Notes) 1,-WI2 1 120 13.033 '''''Route 2'•''' Sprinkler, E(3'-O), P0(6-0) t 0.125865 -0.652 27 11'-10 40.43 1.3800 10111/2 1.380 13.761 Total(Pt) Route 2 103 10-4 11.2 41.70 1% (See Notes) 1-11% 120 13.863 "Route 3" Sprinkler, E(3'-O), P0(6-0) 91 0 0.133267 -0.652 28 11-10 41.70 1.3800 10-11% 1.461 14.672 Total(Pt) Route 3 104 10'-4 11.2 44.37 11/4 (See T Notes) 1 1'- 111/2 120 15.696 "Route 4" Sprinkler, E(3'-O), PO(6'-O) 9-0 0.149483 -0.652 30 111-10 44.37 1.3800 10-11% 1.638 16.682 Total(Pt) Route 4 105 10-4 11.2 48.72 11/4 (See I Notes) 1 1'- 111/2 120 18.919 '''' Route 5''''' Sprinkler, E(3'-O), P0(6-0) t 9-0 0.177676 -0.652 31 11'-10 48.72 1.3800 10-11% 1.947 20.215 Total(Pt) Route 5 106 10-4 11.2 54.99 1% (See T Notes) 1 1'- 111/2 120 24.108 "Route 6" Sprinkler, E(3'-O), PO(6'-O) f go 0.222327 -0.652 32 11-10 54.99 1.3800 -il 10, 1/2 2.436 25.893 Total(Pt) Route 6 107 10-4 11.2 63.45 1 (See T Notes) 1-11% 120 32.098 "Route 7" Sprinkler, E(3'-O), P0(6-0) 91-0 0.289727 -0.652 33 ll'-lO 63.45 1.3800 10'-ll% 1 3.175 34.621 Total(Pt) Route 7 21 4-0 229.42 10 85-1 150 124.945 ''''' Route 8''''' Flow (q) from Route 1 0.000062 0.002 2 -3'-0 104.32 8.6780 85-1 0.005 2 4-0 10 (See Notes) 33'31/2 150 124.952 T(37'-6) 37'-6 0.000062 ii 4-0 104.32 8.6780 380-9% 0.024 11 4-0 8 (See Notes) 432'71/2 150 124.975 T(18'-8%) 18-8% 0.000264 -0.003 29 4-0 104.32 6.4470 451-3% 0.119 f,©M.E.P.CAD, Inc. iffi AutoSPRINK 2020 BETA vl6.3.1.0 1 4/1/2021 12:06:34PM Page 9 ,Job Name: Drawingi Remote Area Number: Date: 4/1/2021 Pipe Information Node I Elev I Flow added Fittings & Length C Factor Total(Pt) Notes (Foot) K-Factor this step Nominal ID Devices (Foot) FittinglDevice (Equivalent (q) Equiv. Length) Fixed Pressure Losses, __ Fitting (Foot) Pf Friction Elev(Pe) Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit (psi) when applicable, are added Total (Foot) (Q) (Foot) (Foot) Friction(Pf) directly to (Pt) and shown as nagfiup 29 -3'-O 8 (See 65191/2 150 125.092 0.000 Notes) 1 4-0 104.32 6.4470 0.000264 S 651-9% 0.172 125.264 Total(Pt) Route 8 1,©M.E.P.CAD, Inc. AutoSPRINK2O20BETAv16.3.1.O 1 4/1/2021 12:06:34PM Page 10 S Job Name: Drawingi Remote Area Number: I Date: 4/1/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) II C Value Multiplier Actual Inside Diameter 4.87 = Factor Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111h° Elbow Ee2 221/2° Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. olAutoSPRINK 2020 BETA 06.3.1.0 1 4/1/2021 12:06:34PM Page 11 01TAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION MATERIAL SUBMITTAL BEACON BLDG. B 7740 EL CAMINO REAL CARLSBAD, CA. 92009 CONTRACT NO. 21176 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page &t 1TAN FIRE PROTECTION Fire Protection Contractor - License #989280 TABLE OF CONTENTS SPRINKLERS OVERHEAD PIPE AND FITTINGS HANGERS AND SEISMIC VALVES OTHER 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page Page 1 of 4 MICROFAST® QUICK "sill(I F*t1G ® SPRINKLER VK300 (K5.6) RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfas& Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated SDrinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286/141° = G For example, sprinkler VK3001with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 2 of 4 MICROFAST® QUICK "4JIF(I I4.J SPRINKLER VK300 (K5.6) RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. f:1!AAVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Color B lb U Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 F (38 C) Orange Ordinary 155 °F (68 °C) 100 ¶ (38 °C) Red Intermediate 175 °F (79 C) 150 ¶ (65 °C) Yellow Intermediate 200 °F (93 C) 150 ¶ (65 °C) Green High 286 °F (141 °C) 225 °F (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 ¶ (57 C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap— Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 18.10.11 Rev 17.1.P65 Page 3 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY Ftrtsh Microfast' Quick Response AiX 4- Escutcheon (f applicable)I Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size I Nominal K-Factor I Overall Length SIN Number' I Listings and Approvals3 VdS NPT I 13,15-I I U.S. I metric2 Inches mm cULus I LPCB I NYC8 I CE 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 1 56 Al, B2 -- Seefootnote7.I -- •V 06661B VK300 1/2" 115mm NOTICE - Product 5•680.6 F -2-3/16 56 1 Al, B2 -- See footnote 7. -- Approved Temperature Ratings Approved Finishes A- 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200°F (93 °C), and 286 OF (141°C) 1 - Brass, Chrome, White Polyester56, and Black Polyester56 B - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and 286 OF (141°C) 2 - ENT; Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada 'Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 'Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA -UL (Also refer to Approval Chart I above) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Page 4 of 4 MICROFAST® QUICK l:II[.,i.Iyiy RESPONSE UPRIGHT NIKJNG SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY Mlcrofast° Quick Response Finish I AIX4- Escutcheon (if applicable)I Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. I metric2 Inches mm 12978 VK300 1/2" 15 mm 5.6 1 80.6 2-3/16 56 Al, B2 t1tti'7YPrI BelowriLimited Availability Local Viking 1JI111 06661B VK300 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 - Brass, Chrome, White Polyester', and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyester' 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 1 of 7 MIRAGE® STANDARD AND s.j II(IIS1G® I:II[iu'7MA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The 'push-on", "thread-off design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Certificate number 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) WARNING: Cancer and Reproductive Harm- zt Page 2 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'sJ II(lF1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G1 0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 OF (68 °C) = B, 175 OF (79 °C) = D, 200 OF (93 °C) = E For example, sprinkler VK463 with a 155 OF (68 °C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 OF (57 °C) UL (139 OF (59 °C) FM and LPCB) = A, 165 OF (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 OF (74 °C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 OF (57 °C) UL (139 OF (59 °C) FM and LPCB) = A, 165 OF (74 °C) = C For example, cover 21876 with a 165 OF (74 °C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 OF (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT NIKJNG* ® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE AND FINISHES Sprinkler Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Cover Plate Large Cover Square Cover Temperature Temperature Ceiling Assembly (Required) Base Part Plate Base Part Plate Base Part Bulb Color Classification Rating' Temperature2 Number3 Number3 Number3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135 °F (57 °C) cULus 13504 or 218761 13642 or 218751 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175°F (79° C) 150°F (65° C) 165°F (74 °C) 13504 0r218765 13642 or 21875 15394 1 Yellow Intermediate 200°F (93° C) 150°F (65° C) 165°F (74 °C) 13504 0r218765 1 13642 or 2187551 15394 Green Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings4: ENT Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. \ NIKING° I All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers -4 4 3-5/16" (84 mm) Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT lP%J II(II16i® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) I SpriniderTempefature Rating fCover Plate Temperature Rating Mirage® Concealed Pendent Sprinklers VK462 and VK463 AWl. Cover Plate Finish KEY - Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.1 I Inch mm U.S. meti1c2 Pressure cULus5 NYC I VdS7 I LPCB 12 Standard Response Applications 13503A VK462 1/2" -- 5.6 80.6 175 psi (12 bar) - -- AY1,CZI AYI,BZ1 AY1,CZ18 AY3 - 19785A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - -- - -- -- -- AY2, CZ2 21356A VK462 - 15 5.6 80.6 175 psi (12 bar) - -- - -- -- - AY2, CZ2 Quick Response Applications 13503A VK462 1/2' 15 5.6 80.6 175 P51 (12 bar) AV1, BX1, AV1, BX16 - - -- AY3 -- AS3, BT3 AV1, BX1, 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX16 - - -- -- -- AS3, BT3 13667A VK463 1/2" 15 5.6 80.6 1250 psi (17.2 bar)' AV1, BX1 I AV1, BX16 - -- -- -- -- Cover Plate Assembly Temperature Ratings1'9 Sprinkler Temperature S - 135 OF (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Ratings T - 165 OF (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155 "F (68 °C) OF "C) V - 135 (57 cULus Listed cover 13504, 13642 (large diameter), or 15394 (square cover plate) Brass, Brushed Brass, Brushed Copper, Painted White, B - 175 OF (79 °C) and 200 OF x - 165 OF (74 "C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 °C) Y - 135 OF (57 °C) cover 13504 LPCB Approved as 139 OF 2 - Brass C - 200 °F (93 C) (59 °C) 3 - Stainless Steel Z - 165 OF (74 °C) cover 13504 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139 OF cover has an orange label. The 165 OF (74 °C) cover has a white label. ID Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. 11 IVIED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 5 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also (Also refer to Approval Chart 1) cUL.us Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6ff. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Anoroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN 12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type Domed-CCP shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 6 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'J II(IIs1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) I —SpTp I — CoverPtateTemperatureRatmg Mirages Standard Response Concealed Pendent Sprinkler VK462 AWI4- Cover Plate Finish KEY Sprinkler Base NPT Thread Size I Nominal K-Factor Maximum I FM Approvals3 Part No.' SIN I I i I I Water Working I (Refer also to Design Criteria below.) Inch I mm I U.S. I metric; Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Ratings14 Cover Plate Assembly Finishes' y. 139°F (59 °C) cover 21875 or 21876 Sprinkler Temperature Ratings z - 165 °F (74 °C) Cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A- 155 °F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175 °F (79 °C) and 200 °F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above) Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 7 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT N411aw SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap removed Use wrench 14047WB** Sprinkler Wrench - Part No. 14047WB** Step 1: Carefully slide the wrench sideways around the deflector and pins 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler Sprinkler wrench fla frame arms Ln 1/2" (15 mm) NPT 2-9116" (65 mm) Maximum - 2-1/16" (52 mm) Minimum - - - 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 STANDARD/QUICK RESPONSE! EXTENDED COVERAGE 'jjj IIJFs1G® l.4:llEu.J.Iv PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Light and Ordinary Hazard density re- quirements at lower pressures than standard orifice or large orifice sprinklers. The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. Pendent Sprinkler VK534 is cULus Listed as standard and quick response. The special Polyester and Electroless Nickel FIFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, ENT coating has been investigated for installation in corrosive atmospheres. See Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to Approval Chart 1 and Design Criteria cULus Listing requirements. 3. TECHNICAL DATA C NOTE: As of May 2018 all logos have been re- moved from the wrench boss. WARNING: Cancer and Reproductive Harm- Specifications: www.P65Warnings.ca.gov Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K-Factor: 11.2 U.S. (161.3 metrict) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (61 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C 11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinkler: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking EC/QREC Pendent Sprinkler VK534 by first adding the appropriate suffix for the sprinkler finish and then the appro- priate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, and 286 °F (141 °C) = G For example, sprinkler VK534 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 08340AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website) Sprinkler Wrenches: Standard Wrench: Part No. 05118CW/B (available since 1981) Wrench for recessed pendent sprinkler: Part No. 11663W/B** (available since 2001) **A 1A" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_051393 19.02.21 Rev 19.1 Replaces Form F 051393 Rev 18.2.P65 (Removed F-i Escutcheon.) Page 2 of 6 STANDARD/QUICK RESPONSE t EXTENDED COVERAGE J II(IIS1j PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking EC/QREC Pendent Sprinkler VK534 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_051393 19.02.21 Rev 19.1 Page 3 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE 41KJNG4 l:III.q..•.yIf. PENDENT SPRINKLER VK534(KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature l Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester', Black Polyester', and ENT Corrosion-Resistant Coatings4: ENT Footnotes l The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT sprinklers, all exposed surfaces and the waterway are coated, but note that the spring is exposed. Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Pendent Sprinkler wren must be usec. .. .. . wax coated sprinklers. ** A 1/2" ratchet is required (not available from Viking) 'r1r Step 2: Carefully press the wrench upward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 11663W/B for Recessed Pendent Sprinkler VK534 19 1 Page 4 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE tJ II(IFttr,1G® l:II[.qu.yv. PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Temperature KEY Approval chart I (UL) , L1 SRIQR EC Pendent Sprinkler VK534 AIX4 Escutcon(ifapptcab Sprinkler Base SIN I NPT Thread Size I Nominal K-Factor I Maximum Water Overall Length I Inches I mm I U.S. metric2 Inches I mm Part Number' Working Pressure 08340 Pendent VK534 3/4 20 11.2 161.3 175 psi (12 Bar) 2-5/16 59 Minimum Water Supply Requirements' Listings and Approvals3 Max. Sprinkler Maximum (Refer also to UL Design Spacing Area per Criteria) (Lx W7) Sprinkler Light Hazard Ordinary Hazard Group I Ordinary Hazard Group II Flow! Pressure Flow I Pressure Flow I Pressure cULus4 Standard Response 16 ft. x 16 ft. (4.9 256 ft2 (23.8 -- 38 gpm @ 11.5 psi 51 gpm @20.7 psi C1W, D1Y, D2Z, C2W m x4.9 m) m2) (143.9 Umin @ .79 Bar) (193.1 L/min @ 1.43 Bar) 18 ft. x 18 ft. (5.5 324 ft2 (30.1 - 49 gpm @ 19.1 psi 65 gpm @33.7 psi C1W, D1Y, D2Z, C2W m 5.5 m) m2) (185.5 Umin @ 1.32 Bar) (246.1 L/min @2.32 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 - 60 gpm @28.7 psi 80 gpm @51.0 psi C1W, D1Y, D2Z, C2W m 6.1 m) m2) (227.1 Umin @ 1.98 Bar) (302.8 L/min @3.52 Bar) Quick Response 12 ft. x 12 ft. (3.7 144 ft2 30 gpm @7.2 psi 39 gpm @ 12.1 psi m 3.7 m) (13.4 m2) -- (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) ElY, E2Z 14 ft. x 14 ft. (4.3 196 ft2 -- 30 gpm @ 7.2 psi 39 gpm @ 12.1 psi ElY, E2Z m x4.3 m) (18.2 m2) (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 16 ft. x 16 ft. (4.9 256 ft2 (23.8 30 gpm @7.2 psi -- -- B1Y, F2Z m x 4.9 m) m2) (113.6 L/min @ .50 Bar) 18 ft. x 18 ft. (5.5 324 ft2 (30.1 33 gpm @8.7 psi (124.9 U -- -- B1Y, F2Z m x 5.5 m) m2) mm @ .60 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 40 gpm @ 12.8 psi (151.4 -- -- A1Y, G2Z m 6.1 m) m2) Umin @ .88 Bar) Approved Temperature Ratings A - 135°F (57 °C) and 175°F (79 °C) Approved Escutcheons B - 135°F (57 °C), 155°F (68 °C), and 175°F (79 °C) Approved Finishes W - Standard surface-mounted escutcheons only C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and Y - Standard surface-mounted escutcheons or the Microfast5 286 OF (141 °C) 1 Brass White Polyester, - , Chrome ' and Black Model F-i Adjustable Escutcheon, or recessed with the D - 155°F (68 °C), 175°F (79 °C), and 200°F (93 °C) Polyester 2- ENT' Micromatice Model E-i, E-2, or E-3 Recessed Escutcheon E - 155 OF (68 °C) Z - Standard surface-mounted escutcheons or the Micromatic F - 155 OF (68 °C), and 175 OF (79 °C) Model E-i Recessed Escutcheon. G - 175 OF (79 °C) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. cULus Listed for use in the U.S. and Canada. To determine 'Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the "Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10-6" x 13-0" sprinkler spacing, provide the "Minimum Water Supply Requirement" listed in the chart for 14-0" x 14-0" spacing. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the "Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement" used. 6 cULus Listed as corrosion-resistant. Form No. F_051393 19.02.21 Rev 19.1 Page 5 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE 4J II(IIs16i® l:II[.q.1u.yM.. PENDENT SPRINKLER VK534 (K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: EC-ELO Pendent Sprinkler VK534 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers as indicated below: The minimum water supplies and maximum areas of coverage shown in Approval Chart 1 are designed to provide the following design densities: 0.10 gpm/ft2 (4.1 mm/mm) for Light Hazard densities; 0.15 gpm/ft2 (6.1 mm/mm) for Ordinary-Hazard Group I densities; 0.2 gpm/ft.2 (8.1 mm/mm) for Ordinary-Hazard Group II densities. The sprinkler installation rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. Viking EC-ELO Pendent Sprinklers are cULus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. Ceiling slope not to exceed 2/12 (950) Also. Viking ECOH-ELO Pendent Sprinkler VK534 is specifically cULus Listed for Ordinary Hazard Occupancies: For non-combustible obstructed construction within trusses or bar joists having non-combustible web members greater than 1" (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under "Obstructions to Sprinkler Discharge Pattern Development". For installation under concrete tees when installed as follows: The stems of the concrete tee construction must be spaced between 3 ft (0.9 m) and 7 ft-6 in (2.3 m) on center. The depth of the concrete tees must not exceed 30 in (762 mm). The maximum permitted concrete tee length is 32 ft (9.8 m). However, where the concrete tee length exceeds 32 ft (9.8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 ft (9.8 m). The sprinkler deflector is to be located in a horizontal plane at or above 1" (25.4 mm) below the bottom of the concrete tee stems. IMPORTANT: Always refer to Bulletin Form No. F091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_051393 19.02.21 Rev 19.1 1-1/8" 29 mm) Mm. 1-1/8" 2" (29 mm) (51 mm) Mm. Max. - (54 mm) Page 6of6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 3/4,, (20 mm) NPT j Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-3/8" (60 mm) 1-1/2" (38 mm) ;rrr 1 1-3/4" (45 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-1I8"-- .'T,lJ (54 mm) I 1-3/4" 4L LI (45 mm) Max. Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_051393 19.02.21 Rev 19.1 Replaces Form F_051393 Rev 18.2.P65 (Removed F-i Escutcheon.) FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe L II d--D iF II 1 1.315 1.097 1.41 lbs/ft 91 11/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe 11mag11 it It 1 1.315 1.049 1.68 lbs/ft 70 11/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.260 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Chesterfield, MO 63017 contact your salesperson C®US 1819 Clarkson Road For additional information, 8 6 (800) 325-4467 today at (800) 325-4467 or BULL. MOOSE TI..E CDAPANY FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada AC company e-mail: sa1esc.bu11moosetube.com call (800) 882666 ______ <6> APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 NO. 20 TEE NO. 10 ELBOW ALTERNATE STYLES Victaulic offers a broad line of fittings in sizes through 60'/1500mm in a variety of straight and reducing styles. Most standard fillings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 14.04 for fittings available for plain end applications). Fillings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fillings are designed specifically for use in grooved piping systems. Fillings are provided grooved conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fillings with 741 or 743 Vic-Flange® adapters, check disc clearance dimensions with I.D. dimension of filling. Note: The following Victaulic fillings are VdS approved: No.10 90" Elbow, No.11 45" Elbow, No.20 Tee and No.60 Cap. Note: The following Victaulic fillings are LPCB approved: No.10 90" Elbow, No.11 45" Elbow, No.12 221/2" Elbow, No.13 111/4" Elbow, No.30 45" Lateral, No.30-R Reducing Lateral, No.100 Long Radius Elbow, No. 110 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee, No.33 True Wye, No.50 Concentric Reducer, No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Advanced Groove System - For 14— 60/350 - 1500 mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS filling details. Stainless Steel - Grooved end fillings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Filling center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum - Grooved end fillings are available in aluminum alloy 356 T6, in sizes from 1 - 8/25 - 200mm. Refer to Section 21.03 or contact Victaulic for details. Fabricated Steel - A full range of fabricated segemtnally welded steel or full flow grooved end fillings are available refer to section 07.04. Fabricated Steel with AGS Vic-Rings - A full range of full flow fabricated fillings with Vic-Rings are also available. AGS - ADVANCED GROOVE SYSTEM Extra Heavy EndSeal® "ES" Fittings - EndSeal fillings are available in 2— 12/50 - 300mm for use with "ES" grooved pipe and HP-70ES EndSeal couplings. "ES" fillings are painted black for easy identification. EndSeal (and standard) fillings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fillings" when ordering. See Section 07.03 for information on EndSeal fillings. Fittings Machined for Rubber or Urethane Lining (MRL) - For severe abrasive services, Victaulic fillings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. Note: Fillings are available with a variety of coatings upon request such as hot dip galvanized, epoxy, glass lined and others. JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved www.victaulic.com ITAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_R A—c—ta—ulice 07.01_i CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) 3/4 - 4/20 - 100mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F 5— 6/125 - 150mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type E or S, Gr. B 8— 12/200 - 300 mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type E or S, Gr. B Flanged Adapter Nipples: (Nipple - see above) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com j41 tauiace vICTAULIC IS REGISTERED TRADEMARK OF vICTAuuC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.012 REV CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 22½0 elbow is one-nan me resistance 01 a 45 elbow. Values 01 miu-sizes can be 1 1.315 1.7 0.8 4.2 1.7 25 33.7 - --4-. 2.375 0.5 - + - 3.5 - -- 2.5 0.2 -4-. -- 1.8 - -4-- - - 1.1 - -I--- 13 - - - 8.5 0.5 - 3.5 2 50 60.3 3.000 1.1 4.3 0.8 0.5 2.1 0.3 2.6 10.8 1.1 4.3 76.1 mm 76.1 . 3.500 1.3 ' 5.0 I------------~-. - 3.8 0.7 . 2.6 - -.--------, 1.6 , 3.3 13.0 1.3 - 5.0 3 80 88.9 -----4--- 4.250 1.5 -+ - 6.4 1.2 0.8 .___ 3.2 4- - 0.5 . 4-____ 4.0 ' _4__ 15.3 1.5 6.4 108.0 mm 108.0 4.500 ' 2.0 - -.,--- 6.8 - 5.0 0.9 . 3.4 ------4------- ' - 1 2.1 -1----------.------------ 4.7 16.0 2.0 6.8 4 100 114.3 5.250 2.1 8.1 1.5 1.0 4.1 0.6 4.9 20.0 2.1 8.1 mm . 133.0 5.500 2.5 8.5 ' - 1.2 4.2 - ' 6.2 21.0 2.5 8.5 9. mm 139.7 5.563 2.6 8.5 - 1.3 42 - 6.4 21.0 2.6 8.5 5 125 141.3 - - 6.250 ____-4-. 159.0 2.6 , .. 9.4 - 1.3 4.9 - 6.4 25.0 2.6 9.6 mm 159.0 -- ~ 6.500 - + 165.1 2.9 ' 9.6 - 1.5 5.0 - 7.6- -- 25,0 2.9 - .- - 10.0 mm 165.1 6.625 2.9 10.0 ' - 7.5 1.5 5.0 - 3.0 ..4____ 7.6 25.0 3.0 10.0 6 150 168.3 8.625 3.0 13.0 2.3 9.8 1.5 6.5 0.9 4.0 ' 7.6 33.0 ' 3.0 13.0 8 200 219.1 10.750 I 4.0 17.0 ' 3.0 12.0 2.0 8.3 1.2 5.0 10.1 41.0 . 4.0 17.0 10 250 273.0 12.750 . 5.2 20.0 3.7 14.5 2.5 10.0 1.5 6.0 12.5 50.0 5.2 20.0 12 300 3239 - ----- 14,000 6.1 - - 24.5 § . 4.4 15.8 3.0 I ' 18.55 1.8 11.0 -- 15.2 - - --- 70.0 . 6.1 - 23.0 ______ 14 350 355.6 16.000 7.5 28.05 4.8 18.0 5.6 21.08 3.4 13.0 21.3 80.0 7.0 27.0 16 400 406.4 18.000 -t- ----- 8.5 --- t.......-.±- 31.05 5.5 20.0 6.4 23.55 .--.-. 4,0 - .-- 14.0 -+-.-.- . 24.4 90.0 ' -~------- 8.2 30.0 18 450 457.0 20.000 9.5 . + . 34.05 6.1 - - 22.5 7.2 - - .. . 25.55 4.3 . -+ . 16.0 . .f.. 27.4 - -. 100.0 9.1 33.0 20 800 508.0 ' 24.000 10.4 42.05 . 6.9 27.0 7.8 . 29.5 § 4.9 19.0 I 30.5 120.0 10.1 40.0 24 600 610.0 -- 12.8_ 82 9.0 5.8 36.6 12.2 , ,,, , , -- Fittings available up to 60/1500 mm. Contact Victaulic for details. # Contact Victaulic for details. S For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Fitting flow data for 14-247350-600 mm size No. 10 and No. 11 Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings (No. W10 and No. Wil Elbows), refer to submittal 20.05. Note: All fittings are ductile iron unless otherwise noted with an 'sw' or "s". S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_R JtauIic 07.013 FLOW DATA (Frictional Resistance) CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee -CtoE1 -CtoE.1 NO. 25 Grooved Branch I NO. 291 Threaded Branch to to l) C4 C E NO. 25 NO. 291 e- C to E - to Ep- * NO. 25-SW C to E Lo NO. 291-SW 3 I U IL 1 X 1 ¼ X 2.25 sw 2.24 sw 1.0 25 20 57 57 0.5 11/4 11/4 1 2.75 sw 2.75 sw 13 32 32 25 70 70 1 0.6 11/2 1½ 3/4 2.75 . 2.755w 1.5 40 40 x 20 70 70 0.7 1 2.75 sw - - I 2.75 sw 1.5 25 70 70 0.7 --. ---.- 1¼ 2,75 sw 2.75 sw 1.7 32 70 70 0.8 3.25 1 2.5 2 2 Y4 3.25 50 50 20 83 83 1.1 1 3.25 3.25 2.7 25 __83,, 83 1.2 11/4 3.25 sw 3.25 sw 1.8 -a- 1 ½ 3.25 3.25 sw I 3.0 40 -- 83 3.75sw 83J 1.4 3.9 2½ 2½ 1/4 3.75sw 65 X 65 X 20 95 95 1.8 - 1 25 95 95 1.7 1¼ 3.75 sw , 3,75sw 4.2 32 95 95 1.7 3.75 3.75 3.9 1 ½ 40 95 18 --- .--- --- 2 3.75 3.755w 4.5 50 95 4.25 sw 95 2.0 4.25 sw 5.7 3 3 3/4 x 80 80 20 108 108 2.6 ---- --+-.... 1 4.25 4.25 6.1 25 108 108 2.8 11/4 4.25 sw 4.25 sw 8.0 32 108 108 3.6 - 11/2 4.25 4.25 sw 6.5 40 108 ' 108 2.9 2 4.25 4.255w I 6.2 50 108- 108 2.8 ........ 2½ 4.25 4.25 sw 6.4 65 108 5.00 sw 108 2.9 5.00 sw 8.0 4 4 3/4 100 100 20 127 127 3.6 1 5.00 5.00 7.8 25 127 . 127 . 3.5 4 4 x x 1¼ 5.00sw 5.00 SW 9.6 100 100 32 127 127 4.4 5.00 - 5.00 10.2 11/2 40 127 1274 4 2 5.00 ' 5.00 11.2 50 127 127 5.1 21/2 5.00 5.00 11.4 65 127 127 ' 5.2 ---,--.- 3 5.00 5.00 1 11.6 80 127 5.50sw . 127 5.50sw 5.3 14.0 5 5 1 125 125 x 25 140 140 1 6.4 11/2 5.50sw 5.50sw 14.3 40 140 140 . 6.5 2 5.50sw 5.50sw 14.5 50 140 140 6.6 2½ 5.50 5.50sw ' 15.2 65 140 140 6.9 3 550 5.505w 16.6 80 140 140 7.5 - ''I-- -- - - - 4 5.50 5.50sw . 16.7 100 140 6.50 sw I 140 -- 6.50 sw 7.6 23.0 6 6 1 150 x 150 x 25 165 1 165 10.4 1½ 6.50sw 6.50sw 24,0 40 165 165 10.9 6.50 ' 6.50 21.6 2 50 165 165 1 9.8 -ff 2½ -r 6.50 21.4 65 165 165 . 11.7 14-60 M 350-1500m AGSFor AGS fitting information, see publication 20.05 + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an 'sw' or "s' S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 291 Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. C 2012 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. 07.0110 4tauiicr REVR CARBON STEEL PIPE - GROOVED FITTINGS iMii Grooved End Fittings Reducing Tee CtoE1 - CtoE.j CtoE41 - CtoE NO. 25 Grooved Branch T NO. 291 Threaded Branch C LI1i to to to to E NO. 25 NO. 291 NO. 25-SW NO. 29T-SW I . I ar 1.1 &U 1~ 2Z 6 6 x 3 6.50 6.50 26.5 12 12 1 10.00sw 10.O0sw 77.0 150 150 80 165- -+- -- 165 -4. 12.0 300 300 25 254 254 34.9 4 6.50 6.50 - 25.0 - 2 10.005w 10.005w 80.0 100 165 165 11.3 50 254 254 36.3 5 6.50 6.50 23.2 21/2 10.00sw 10,005w 78.0 125 165 6.50 165 6.50sw 10.5 24.0 65 254 254 35.4 - 3 10.00sw 10.00sw 82.0 616 61/2 3 165.1 165.1 x 80 165 165 10.9 80 254 254 37.2 - ------4. - - 4 6.50 6.50sw 25.0 4 10.00sw 10.00sw 80.0 100 165 7.75sw 165 7.75sw ± 11.3 - . --- 33.0 100 254 ' 254 36.3 - . - .- ---,- - -- 5 10.00sw 10.00sw 75.0 8 8 1½ 200 x 200 40 197 .---_--------+_-----_---- ' 197 4-- 15.0 125 254 254 34.0 - ..4 - _. 2 7.755w 775 s -- 33.5 6 10.00sw 10.005w 75.0 50 197 197 15.2 150 254 254 34.0 .-- 21/2 7.75sw 7.75sw 39.0 8 10.005w 10.005w 80.0 65 197 197 17,7 200 254 254 36.3 3 775 s 775 s 33.6 10 10.00sw 10.00sw 84.0 80 197 4- 197 --. -. 15.2. 250 254 254 38.1 . - .--- -+ -. - . 4 775 775 41.8 . - #14 14 4 11.005w 11.005w 102.0 100 197 197 19.0 - - 350 X 350 X 100 - 279 - 279 - 46.3 5 7.75sw 7.75sw 34.0 6 11.00sw 11.00sw 108.2 125 197 197 15.4 150 279 279 49.1 - 6 7.75 7.75 42.3 8 j 11.00 11.00 112.0 150 197 197 19.2 200 I 279 279 50.8 1651 7.75sw 775sw 48.0 - 10 11.00 11.00 120.0 197 - 9.00 4-----.-- 197 .....- 9.00 -- 21.8 -- -- 62.0 300 I 279 279 54.4 -f----------.---•--- 12 11.00 11.00 129.1 10 10 1½ x x 250 250 40 229 --4----.-. 229 28.1 - ....._________ 58.6 300 279 279,---,- --.------ ----- 2 9.00 Sw - 9.00 Sw - 62.0 # 16 16 4 130.0 50 229 229 28.1 400 400 x 100 + + 59.0 65 229 229 - 283 350-1500mm [4 For AGS fitting information see publication 2005 3 9.00sw 9.005w 60.0 + Contact Victaulic for details. 80 229 229 27.2 ' Note: All fittings are ductile iron unless otherwise noted with an "sw" or 4 900sw 9.00sw 61.0 100 - 229 229 27.7 , --__________ S= Carbon Steel Direct Roll Groove (OGS) 5 9.00sw ' 9.00sw 52.0 SW= Carbon Steel Segmentally Welded 125 229 229 23.6 IMPORTANT NOTE; 6 9.00 SW ' 9005w 590 150 229 229 26.8 No. 291 Threaded Outlet Reducing Tees are supplied NPT and are available 8 9.00sw - - - 900sw 64.7 - - with British Standard threads. For British Standard specify "BSP" clearly 200 229 229 29.3 on order. It For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. •ctaul.0 REV_R 07.01_11 CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings Reducing Tee NO. 25 Grooved Branch NO. 29T Threaded Branch #16 16 x 6 x 12.00sw 12.00sw 133.5 400 400 150 305 305 _60.6 _._ 8 12.00 i 12.00 145.0 200 305 305 65.8 10 12.00 12.00 149.5 250 305 305 67.8 ____--.-.--- +--- 12 12.00 i 12.00 154.0 300 305 305 1 69.9 14 12.00sw 167.0 350 305 - 75.8 - ---.- - . -t - - - - - #18 18 4 15.50sw 15.50sw . 194.0 450 x 450 100 394 394 88.0 6 15.50sw 15.505w 200.0 150 394 394 - 90.7 -t.-----------------.- - - 4. 8 15.50sw 15.50sw 202.0 200 394 394 91.6 -- _____- 10 15.50 1 15.50 212.0 250 394 394 96.2 - -- 12 15.50 15.50 222.6 300 394 394 101.0 1- --------- -1- - 14 15.50 230.1 350 394 .. -.. ----_-.-- 16 15.50 247.6 400 394 - 112.3 +-.--- ......+ - #20 20 6 x 17.25 17.25 240.0 500 500 150 438 438 108.9 8 1 17.25 17.25 244.0 200 1 438 438 ._.:_- 110.7 10 17.25 17.25 - 256.0 250 438 - 438 - 1161 4.-.- 12 17.25 17.25 . 264.0 300 438 438 1198 -F-- - ---4---- ....-- 14 17.25 - 275.0 350 438 - 124.7 07.01 C to C C to to NO. 25 NO. 29T #20 x 20 16 17.25 - 288.6 500 500 400 438 - 130.9 18 17.25 297.0 450 _ 38 - 134.7 # 24 24 8 20.00 20.00 340.0 600 600 x 200 508 - - 1542 10 20.00 20.00 . 343.9 250 508 508 156.00 12 20.00 20.00 352.8 300 508 508 160.0 ............ 14 § 20.00 - 360.0 350 508 - - 163.3 16 20.00 378.0 400 508 - 171.5 4 ........... 188 20.00 - 380.0 450 508 - . 172.4 - .+- .............. 20 20.00 373.0 500 508 - 169.2 14- 60" AGSFor AGS fitting information see publication 20.05 350-1500mm + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s' S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 291 Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Cast fitting available. Contact Victaulic for details. www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.0112 ,NJ tauIicr REV_R INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 0812012 \j$t9UIiC' 07.01 1449 REV R VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIc COMPANY. © 2012 VICTAULiC COMPANY. ALL RIGHTS RESERVED. 07.01 jfinr.!i1u1rnT STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe 1¼ 175 365 365 365 365 32~12062517 2517 2517 2517 1½ 175 365 365 365 365 40 1206 . 2517 2517 2517 2517 2 175 365 365 365 365 - 50 1206_+_2517 2517 2517 2517 21h N/A 365 365 365 365 2517 27 2517 2517 76.1 mm N/A N/A 365 365 365 2517** 2517 2517 N/A 365 365 365 365 0 -- - 2517 25i7.... 2517 2517 + W8mmN/A 4 N/A 365 365 '• 365 365 100 2517 2517 2517 2517 133 mm N/A N/A N/A 2k**'232 365 139.7 mm N/A N/A 1999 1600 2517 165.1 mm + N/A N/A 290 232 365 1999 1600 2517 - 6# N/A 290 365 - 232 365 * Listed/Approved for wet and dry pipe systems (>-40°F/-40°C). Please refer to the Victaulic Installation Manual (1-009H_009_009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) P Regional availability only# FM Approved only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G \4tauIic 10.611 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H LISTINGS/APPROVALS * Speciality Pipe BLT - 300 I 1Y4-2 300 2068 2068 —F OF I 1 300 300¼-4 ___ 2068 • 2068 DT 300 t I 1 ¼ - 2 300 2068 2068 EF 175 I 1¼-4 175 1206 - 1206 EL 300 I 14-2 300 2068 - -- 2068 ET40 300 1 ¼ - 2 300 2068 2068 EZF 300 - 300 2068 2068 EZT 1¼-2 300 300 2068 2068 300 300 FF 11/4-4 2068 2068 FLF 11/4-4 N/A 300 2068 FLT I 1 1/4 N/A 300-2 2.068 ii FLTL I - 1 1/4 - 2 N/A 300 2068 GL 1¼-2 300 300 JMF 2068 2068 1 ¼ - 300 300 2068 2068 MT 1¼-2 300 300 - - 2068 - 2068 MLT 11/4-2 N/A 300 2068 ST I 1¼-2 N/A 300 2068 STE 11/4-4 - N/A 300 2068 IF - 21/4-4 N/A 300 2068 WLS 11/4 - 2 300 300 2068 2068 WST 1 ¼ -2 N/A 75 1206 XL I 14-2 Note: The Specialty Pipe table only applies to imperial sizes, NOT to metric sizes. www.victaulic.com \)1$$tauIic0 vlclAuLlc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAUUC COMPANY. ALL RIGHTS RESERVED. 10.612 REVG IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1 0.6 1 FireLock EZ® Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS Y ~Z 1011 IL__ealvitTelis... X 1¼ 1.660 365 790 0.10 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1.4 32 42.4 2517 3514 2.54 -M10x2 75 121 69 118 49 0.7 ------------------------- 1½ 1.900 365 1035 0.10 2 -3/8x2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 + -4- -,.- -- 4604 2.54 -M10x2 81 126 75 122 49 0.7 --- . --4-. -.--+ STYLE 009H PRE-ASSEMBLED 2 2.37 5 365 1616 0.12 2 -3/8x2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 + 3.05 ' - Ml0x2 - . + - 4_ - . 96 140 88 138 49 0.9 - -- -- - . . . - 4_ - - . ... - -I----- 2½ 2.875 365 2370 0.12 2 - 3/8 x 2½ 4.29 6.09 3.92 585 193 2.1 Y k-Z-I 65 73.0 2517 10542 3.05 -M10x2½ 109 155 100 149 49 1.0 - - ----4- - . 4-.. 4- . - ± 76.1 ,. .. . 3.000 365 2580 0.12 2 - 3/8 x 2 ½ 4.40 6.31 4.05 5.90 1.93 2.1 mm 76.1 2517 11476 3.05 -M10x2½ 112 160 103 150 . 49 ' 1.0 - 4-'.--4- - - ''t ' - + x 3 3.500 365 3512 0.12 2 - 3/8 x 2½ 4.91 6.70 4.55 6.46 1.93 i 2.3 80 88.9 2517 15622 3.05 -M10x21/2 125 170 116 164 49 1.0 - - ' 4- - -± - - + + - - 4- . 108 mm 4.250 365 5178 0.17 2 - 3/8 x 2 1/2 5.56 7.61 5.27 7.51 2.14 2.8 108.0 2517 23030 4.32 - Mb x 2½ 141 193 134 191 54--_+_ 1.2 --------------- . - - - --+ ----- --. - STYLE 009H JOINT ASSEMBLED 4 4.500 365 5805 0.17 2 - 3/8 x 2½ 5.95 7.82 5.54 7.47 2.14 , 2.9 100 114,3 2517 25822 ' _432 - -M10x21/2 , 151 - + 199 141 - 190 . 55 1.3 --- +----.----.-,+ -- f.-- -----.- 133 mm 5.250 ' 365 7900 0.17 2 - 3/8 x 2 ½ ' 6.66 . 9.11 6.36 9.01 2.14 4.3 133.0 2517 35140 4.33 -M10x21/2 169 232 162 229 55 1.9 - -----'-4------ - ......... - ~ 5.500 365 8620 0.17 2 - 3/8 x 2 ½ 6.75 9.29 6.46 9.23 2.09 4.6 139.7 mm 139.7 2517 38340 4.32 - MIO x 21/2 172 236 164 234 53 2.1 4- ------t"---4 4-- 4- 4---- 1651 mm 6.500 290 9623 0.17 2 - 5/8 x 31/4 7.84 10.93 7.55 10.85 2.11 5.69 165.1 . 1999 42805 4.32 -M160¼ ' 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 2 - 5/8 x 31/4 ' 7.96 11.08 7.67 ' 11.99 ' 2.11 5.92 150 168.3 1999 44469 4.32 - M16 x 31/4 , 202 281 195 , 305 , 54 . 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown in the chart on page 1, specific to pipe schedule and size. The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America, Asia Pacific) Red enamel (Europe) Optional Coatings: Hot dipped galvanized Gasket: Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VIcTAuLIc COMPANY. © 2012 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV.G \4taulicr 10.613 STYLE 009H GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No. 006 end caps containing the EZ" marking on the inside face or No. 60 end caps con- taining the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade E" Type A gaskets. These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.61 5731 REV G UPDATED 09/2012 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIC COMPANY. © 2012 VICTALILIC COMPANY. ALL RIGHTS RESERVED. 10.61 Victaulic® Flexible Coupling Style 75 Exaggerated for clarity Approvals/Listings 0PILPCB] nu-® € See Victaulic publication 10.01 for details See Victaulic publication 02.06 for portable water approvals if applicable. \4tauIac 06.05 I áWARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or NOTICE l • Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 updated 09/2014 Q 2014 Victaulic Company. All rights reserved. 1 iCtaulic 2 ,NJ tauIìcr 06.05 1470 Rev 0 Updated 09/2014 0 2014 Victaulic company. All rights reserved. victaulic.com victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Standard: Orange enamel. El Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE: Additional gasket styles are available, contact Victaulic for details. El Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30"F to +230"F/-34"C to +110"C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73"F/+23"C and hot +180"F/+82"C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. El Grade "1" Nitrile Nitrile (Orange stripe color code). Temperature range 207 to +180"F/29"C to +82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +1507/+66"C or for hot dry air over +140"F/+60"C. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183 victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation3 Centerline3 Bolt/Nut4 X Y Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm kPa N mm Degrees mm/rn (No.) size inches mm mm mm kg 1 1.315 500 680 0-0.06 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 2 - 43' 48 2-~x2 61 108 45 0.6 11/4 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2-10' 38 2-3/sx2 68 117 45 0.6 1 1/2 1.900 500 1420 0-0.06 1 -56' 0.40 2-3/sx2 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1 -31' 26 2-3/sx2 87 133 48 0.8 21/2 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1 - 15' 22 2-3/ex2 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 1 -12' 0.26 2-3/ex2 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4800 0-0.06 0.22 4.50 7.00 1.88 2.9 1 -2' 2-½x234 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 31/2 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 0-54' 2-½x234 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7950 0-0.13 0.34 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 1 -36' 28 2-'/2x23/4 147 204 54 1.9 108.0 mm 4.250 450 6380 0-0. 13 1 -41' 0.35 2- 12 x 70 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 41/2 5.000 450 8820 0-0.13 1 -26' 0.25 2-5/a x3¼ 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 21 156 240 54 2.5 5 5.563 450 10935 0-0.13 0.27 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 1 -18' 23 2-5/8 X3'/e 175 256 54 2.6 133.0 mm 5.250 450 9735 0-0. 13 1 - 21' 0.28 2-16x82.5 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 24 166 238 54 2.7 139.7 mm 5.500 450 10665 0-0.13 1 -18' 0.28 2-%x3¼ 6.80 9.59 2.13 6.3 139.7 3100 47460 0-3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12735 0-0.13 1 -12' 0.21 2-%X3V4 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15525 0-0.13 0.23 8.00 11.07 2.13 7.0 1 -5' 2-5/gx3¼ 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 159.0 mm 6.250 450 13800 0-0.13 1 -9' 0.24 2- 16 x 82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3.2 20 194 266 54 3.1 8 8.625 450 26280 0-0.13 0.18 10.34 13.97 2.13 12.4 200 219.1 3100 116945 1 0-3.2 0-50' 14 2-3/4x4'/4 263 355 59 5.6 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3%_3 ½"/20 -90 mm; 25% for 4/100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 \,_/(taUIiC victaulic.com I Couplings I Flexible I Style 75 1 Publication 06.05 Installation Note Reference should always be made to the -100 Victaulic Field lnstsilat:on Hondhooh for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data and are available in PDF format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaalic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic* is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 __________ FireLock® Fittings \4tau11cr 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: El Orange enamel O Red enamel in Europe, Middle East, Africa, and India o Optional: Hot dipped galvanized Approvals/Listings: LISTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 0 2014 victaulic company. All rights reserved. 1 \4taulicr victaulic.com I FireLock® Fittings I Publication 10.03 Dimensions: C to E 1 to E NO. 001 to I Cto" _ 1a NO. 003 NO. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 450 Elbow Straight Tee Cap Approx. Approx. Approx. Approx. Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. MM mm mm kg mm kg mm kg mm kg 1 ¼ 1.660 0.82 0.3 32 42.4 - - - - - - 21 0.1 11/2 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 76 1.5 57 1.1 76.2 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 139.7 mm 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - 59mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 139.7 7.9 88.9 5.2 139.7 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 2 Xj(tauIicx Mechanical-I® STYLES 920 AND 920N Victaulic Mechanical-p Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures . - the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. - Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N .I housings cannot be mated to each other to achieve a cross connection. Style 920 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "F' nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com vlcrAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV .M Date \ Ac- ta uloc 11.02_i 181i MIA 141- GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS R0BTh • ~IlemaleI- rlr N1TS a 20 IN RkP, kjI 2 /2 (a) a 500 1.50 2.00 2.53 1.61 535 2.75 3.1 50 15 920N 3450 38.1 51 64 - 41 136 70 1.5 - 34(a) a - -t-------4--- 500 -4-- - - 4.-,- 1.50 1.97 - 2.53 -- ~ .- 1.61 535 ~ 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - -- . ... -----------. I -I - __ - -- 1(a) a 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 N 3450 381 47 64 - 41 136 70 14 - + 4- + + ± -- 11/4 (a) to 500 1.75 2.05 2.75 3.00 1.61 535 3.00 3.5 3.2 32 ON 3450 44.5 52 70 76 41 136 76 1.7 1.5 1½ (a) to 500 175 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 920N 3450 .4. 500 44.5 --- 1.50 52 + - ._._ 2.21 70 - 2.74 79 41 1.82 136 5.64 $_ ---+---+----+--- 83 1.7 1.5 -+.------- 2.75 3.0 2½ ½ (a) §a 65 X 15 3450 . 38.1 56 : 70 - 46 143 , 70 1.4 ---.-- 3/4 (a) §a 500 1.50 2.18 2.74 I 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 4- .. f --..-------9-.. 1(a) §a 500 1920N.50 2.06 . 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 . 143 70 1.4 - 1% t (a) a - --r - ---4- 500 - - 1.75 ,- . 2.30 + .- 3.00 - - 3.25 -t- - -- 4- . 1.82 6.29 --.--4---- -4---- 3.00 3.5 - 3.2 32 3450 44.5 58 76- 83 46 160 76 1 ,7 1.5 -4-- "- 4- - - - - --.----- - -'r-- - -4- 9- - --4- - - 11/2 1(a) a 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 300 50.8 1.50 58 76 2.22 2.75 83 46 225 159 6.46 83 1.7 3.18 3.9 1.6 ½ (a) 76.1 x 15 2065 38.1 56 70 - 57 164 81 1.8 - 4- 1/4 (a) 300 1.50 2.19 2,75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 - ' 57 164 81 1.8 - '--+- -- - 1(a) N 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 - 57 164 81 1.7 - - - .-4-.- 1 ¼ (a) a 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 ' 44.5 58 76 84 49 160 76 1.6 . 1.5 ------4 -- +---'-9---+ '-- ---.9-- --9- 1½ (a) a 500 2.00 2.28 3.00 3.31 1.92 ' 6.29 3.25 ' 3.5 3.3 40 3450 . 500 , 50.8 1.50 58 76 4-- -. 4---- - 2.52 . 3.05 84 - -+---------4------- 49 . 2.28 160 6.15 83 1.6 - -----9-- -- -. -4- 2.75 3.4 1.5 3 ½ (a) a 80 15 3450 38.1 64 78 - 58 156 70 1.6 - 3K (a) a , 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 ' 3450 38.1 63 78. - - - ' 58 156 + -- t -------------- - 70 1 - .6 - 1(a) 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 - --. - 3450 -.- - 9- 38.1 4. 61 78 - 58 156 70 1.6 - 1 1/4 (a) to 500 . - 1.75 , . 4 2.55 -- + 3.25 . 3.56 + 2.28 6.15 3.00 - - 4 3.8 -. 3.7 32(b) 3450 445 65 83 90 58 156 76 1.8 1.8 11/2 (a) to 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 -4-50.8 71 89 90 58 156 83 1.9 1.8 - --I ----- - --#----_4. --4--. -4- ---4- - 4. -4---- 2 (a) a 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 920N 3450 500 63.5 2.50 70 3.00 89 90 3.75 58 2.44 . 172 6.72 - 99 388 2.3 2.1 3.8 3½x 2 90 50 3450 63.5 76 - . 95 . 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½ BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VIcTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02012 vicuuc COMPANY. ALL RIGHTS RESERVED, 11.02 .2 \4taulicf REVM GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psiI3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½/SO x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS reIncheslInches . Inches Inc e TABLE CONTINUED FROM PAGE 2 4 1/z (a) n 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 920¼ 3450 38.1 77 90 " 68 178 70 1.8 - 4-- 34 ---------------------------------- (a) n 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 -4--' 1'.8 - --3------ 1(a) s 500 1.50 2.88 3.56 --3.-- 2.69 -3-----+---- 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 - 1 ¼ (a) to 500 1.75 3.08 3.78 4.00 2.69 7.01 . 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 19 1.8 1 1/2 (a) to - - 500 2.00 3.28 4.00 - .f.___4_ 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) to ---- .4__ __..j.. 500 -+ 2.50 - 4- 3.25 . - + 4.00 4.00 2.69 - 7.01 ---4._ 3.88 -. 5.0 - 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 - - 4__. - .4 - .4- - .3. - ---t- - - -+- 2½ (a) t 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 920 3450 69.9 73 102 102 68 186 118 2.6 2.3 4- 500 2.75 -- 76.1 2.88 - 4.00 2.69 ....... 7.34 . ~. 4.63 6.4 mm 3450 69.9 73 - 102 68 186 118 - 2.9 I- - ---i- -.-- 1' - -- ±--- -- --4--- - 3(a) t 500 - 3.50 3.31 - 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 ¼ (a)a 920N - 500 1.75 3.08 - 3.78 2.63 7.64 3.05 5.0 108.0 x 32 3450 44.5 78 96 - 67 194 78 2.3 - - - - - - - . 4. .•__ - . .4.. - - 3-. - - 4. - - 11/2 (a)ri 500 2.00 - 3.28 - 4.00 - 2.63 7.64 3.25 ' 5.0 40 - 3450 50.8 83 102 - 67 194 83 2.3 - 4- 2 (a) 500 2.50 3.25 4.00 2.63 - 7.64 - 4,00 4.0 50 3450 63.5 83 102 - 67 194 102 1.9 - 500 2.75 2.88 4.00 - 4.00 2.63 7.64 ' 4.29 8.0 7.8 76.1 mm -- 3450 - 69.9 73 102 102 67 - 194 109 3.6 3.5 - 4-.-., - . 4.-_ . . 4--.,. 3 (a) 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 920 3450 88.9 84 114 114 67 194 124 3.1 3.0 3. 4- ..--.--.,. .......3.-- .... 5 x 11/2 (a) t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 920 ' 3450 50.8 102 ' 121 121 80 - 246 ' 94 3.4 3.4 2 (a) t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 920 3450 - 63.5 . 102 121 121 80 246 ' 111 3.7 , 3.6 .4 - '4' .-.- -1- -----,-- -3- -- - 4.- - -I--- - -4- --- - -.-- - - -3--. - 21/2 (a) t 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 920 3450 69.9 92 121 121 80 246 118 - 3.8 3.6 76.1 mm 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 1- I ',- ----- +' '4- --4--- -'4---- -4- ---4--, 3(a) t 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 920 3450 88.9 - 97 127 - 118 80 246 135 3.8 4.0 . - - - 4 - 4..--. 4. - .- - 2 500 2.50 3.75 4.50 3.17 8.00 3.88 . 8.0 133.0 x 50 3450 . 63.5 95 114 - 81 . 203 99 ' 3.6 - 4--- '4-- --- . 4---. --r ---3- ----------+ --4.- 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 920 , 3450 , 88.9 97 - 127 - - - 76 240 - 135 3.6 - TABLE CONTINUED ON PG. 4 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. $ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed, Specify "BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services ri LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTALILIC COMPANY. C 2012 VICTAULIc COMPANY. ALL RIGHTS RESERVED. REV M \4ta uliice 11.023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS a ) __ JIM _ _ (M r1m, MTN, mi TABLE CONTINUED FROM PAGE 3 1 ½t 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 I - 139.7 x 40 920N 3450 50.8 96 114 - 84 209 83 3.2 I + 2t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 -- - 50 920N 3450 63.5 95 114 - 84 209 99 4.1 w - 6 1 /a(a) 500 175 443 513 513 379 915 325 51 48 150 32(b) 3450 44.5 112_.4. 130 130 96 232 83 2.3 2.2 -- 4 ..... __._4_._ _.f_ ____4__..__.• - .4_ . --4. - GROOVED OUTLET 1 1/2 (a) to 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a) to 500 2.50 4.38 5.13 . 5.13 3.79 9,15 3.88 6.0 5.6 ________ 50 ' 3450 63.5 111 130 130 96 232 99 2.7 2.5 r i ir 65 920 3450 - 69.9 110 130 130 94 267 118 3.8 3.4 - - 761mrnu : + f 5213691051 - A 2½ 500 2.75 4.01 5.13 5.12 3.69 10.51 - 4.63 8.3 7.6 500 3450 132 94 267 118 3.8 1 3(a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 - 3.8 -1- + .4- + 4- 4(a) to 920 . 500 4.50 3.81 5.75 - 5.38 3.69 10.51 6.25 10.1 1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET - 1½(a) 500 2.00 4.41 5.13 3.63 3.25 7 159.0 x 40 920H 3450 50.8 112 130 - 92 239 - 83 3.5 - --. -* r -- + - -----4--- i--- -4-- 4- -----4-- --' 4-+ 2(a) 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 - Provides a direct branch connection at 50 920N 3450 63.5 111 130 92 239 99 3.6 - - ._-i--_ -f•___f - .4-.-..4. - 4- --.4- ' t any location where a hole can be cut 76.1 mm 920 ' 500 2.75 - 4.38 5.50 5.13 363 9.40 4.63 9.5 - 9.5 in the pipe ' 3450 69.9 lii 140 130 92 239 1184.34.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 ' 14.0 A pressure responsive gasket provides 80 3450 88.9 110 140 130 92 + 239 135 + . the seal 108 0mm 920 500 4.50 - 4.45 - - - 5.38 3.63 9.40 6.12 - 10.0 3450 114.3 113 137 92 239 155 4.5 Request Publication 11.03 for 920 500 4.50 4- 3.81 5.75 - 3.63 + 9.40 6.25 18.0 - Mechanical-T cross assemblies 100 3450 114.3 96.80 - 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe * Center of run to end of fitting. Sizes from 2 x ½/50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4/200 x 100 mm @ See page 7for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services u -PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAuLIC is A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. 02012 VICTAULIC COMPANY, ALL RIGHTS RESERVED. 11.02 4 4tauIicf REVM CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS __ I'- t!Z çj IL ii 1651 x 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 3450 38.1 99 116 - 96 237 70 3.6 - OH TABLE CONTINUED FROM PAGE 4 1/4 a 920N 500 1.75 4.43 5.13 3.79 9,34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - 4- - -----±------± 1½ (a) '('a 920N 500 2.00 4.41 5.13 5.13 3.79 9,34 3.25 8.4 5.4 40 - 4- - 3450 50.8 '-3'- - 112 130. 130 ~ 96- -+ -+-' 237 83 3.8 '-4 2.4 - .4--. - 4- 4- -. '- -.1- GROOVED OUTLET 2(a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 ________ 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a) '('0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 _______ 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) to 920 500 . 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 - 159 4.8 3.8 - 4-- --'4--- ------4-----' 4- - - 4 -- -4- t- 4-- - - -+ - 8 2(a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 x 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 -4------ l'' -,-- - -4 ---------- + - - 21/2 (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET -- - 4--'- - '-4- -------------------4---- - - 76.1 mm a 920 - 500 2.75 5.25 6.25 4.81 12.42 4,56 11.6 3450 69.9 - 133 - 159 122 - 316 116 - 5.3 - - -- ----- --.- --4- --4- --± --. .4- 3(a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4a to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 3450 114.3 122 S' 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). A pressure responsive gasket provides t Available with grooved or female threaded outlet, Specify choice on order. the seal * Center of run to end of fitting. Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-I cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' Pressure rated up to 500 psi/3450 kPa (a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT" clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services LPCB approved for fire protection services Sizes from 2 x 1/2750 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com vICTAuLIc IS REGISTERED TRADEMARK OF vIcTAuLIC COMPANY. 02012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M \4taulicr 11.025 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C,K. Values: P =Q2 Where: LP Q2 Where: vC 2 Q = Flow (GPM) K Q = Flow (m3/h) Q = C x AP Pressure Drop (psi) C= Flow Coefficient Q = K x 0 Pressure Drop (bar) K~ Flow Coefficient Exaggerated for clarity Length of Outlet Size Sch dule OUTLET Equivalent V, _W1 :I:*1I]1i] 40 Carbon Steel Pipe I R!rivIi Values ½ 0.840 15 21.3 + 9.4 '/4 20 1.050 16 267 13.7 1 1.315 21 25 ' 33.7 -- 8 - - - - 1.8 - 48 - 1Y4 - 1.660 I 51/2 50 32 42.7 6429 411 1 ½ 1.900 11 53 40 98.3 45.4 45.4 2 2.375 10½ -- 112 104 50 96 89.1 2½ 2.875 20 12½ 119 150 65 73.0 102 128.5 76.1 mm 3.000 16 - . 161 - .1 ------------ - 3 - 3.500 88 - - - 14 15 1/2 - - - -- 249 - - 213.4 -- 237 80 + 203.1 4.500 20 22 421 401 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of O.165in14.2mm. www.victaulic.com JtauIic. vIcTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vicrAuLic COMPANY. ALL RIGHTS RESERVED. 11.026 REVM CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2 -6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 - 2.875 - 4.500 -- All -- - DF 2755 ~ - - 300 2755 + - 300 2755 - -+------- - 300 1999 - -- 290 1599 + 232 2496 -- 362 21/2 -4 65-100 73.0-114.3 2.875 - 4.500 ± , --------,------$-------- 2065 300 2065 300 .4- 2065 .•. 300 1999 - 290 1599 232 2496 362 21/2-4 65-100 73.0-114.3 - 6.625 All 4- 4 SF - 10 --_+--__---._-...-.-+--..- 2065 300 2065 300 ---- 2065 250 --~__...-- 1999 290 1599 232 2496 362 6 150 168.3 6.625 .30 40 2065 300 2065. . ..... 300 .... 1724 - . 300 1999. 290 1599 232 2496 362 6 150 168.3 - 8.625 1 10 40 2065 400 4- - 2065 - 2065 1999 1599 145 2496 8 200 219.1 8.625 1 2755 300 4- - 250 - 1000 145 - 8 200 219.1 8.625 -I. -- ---'------ 3040 2065 ------- ------- 300 ---+---- -. - 1724 + ----4---• 300 - .......... - 1000 ------------- 145 - 8 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500p5i/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 51125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2165mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com viclAuLic IS A REGISTERED TRADEMARK OF VIcTAuLIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVM \4taulic 11.027 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 ICt9UIiC vicTAuLic IS REGISTERED TRADEMARK OF VIcTAULIc COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L SIGM A Pipa*ng Products Quality - Service - Commitment - Delivered. Malleable Threaded Fittings ALL MALLEABLE THREADED FITTINGS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 197- Standard Spec for Cupola Malleable Iron ASTM A 153- Standard Spec for Zinc Coating (Hot Dip) on Iron and Steel ANSI B 16.3- Malleable Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Ductile Iron Threaded Fittings ALL DUCTILE IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 536- Grade 65-45-12 ASME B 16.3- Ductile Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Cast IronThreaded Fittings ALL CAST IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 128- Class B Standard Spec for Cupola Cast Iron ANSI B 16.4- Cast Iron Threaded Fitting Classes 125 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Steel Pipe Nipples ALL STEEL PIPE NIPPLES MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 53- Standard Spec for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamed ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT www.sigmaco.com Li Dimensions: ANSI B16.3 CLASS 150 OCoating: Black- none; Galvanized- Hot Dip per ASTM All 53 0 Material: Malleable iron per ASTM A197 DThreads: Pipe Threads, General Purpose ASME B1.20.1 Description E Malleable Threaded 90 I ITEM CQDE IEDIMENSEONIII ITEM SIZE I aLAcIciL GALV ] A j[B LWJHI A 3/8" 1M90B0303 1M90B0303G 0.95 0.95 0.17 - 1/2" 1M90B0404 1M90B0404G 1.12 1.12 0.30 3/4" 1M90B0505 1M90B0505G 1.31 1.31 0.45 1" 1M90B0606 1M90B0606G 1.50 1.50 0.73 / - 7 1 1/4" 1M90B0707 1M90B0707G 1.75 1.75 0.97 / 11/2" 1M90B0808 1M90B0808G 1.94 1.94 1.30 /B 2" 1M90B0909 1M90130909G 2.25 2.25 2.06 / - 2 1/2" 1M90131010 1M90131010G 2.70 2.70 3.55 [I i_i 3" 1M90B1111 1M9OB1111G, 3.08 3.08 5.46 LISTED 4" 1M90B1212 1M9081212G 3.79 3.79 8.95 Description 1 1 Malleable Threaded 45 F1qO1VFJ I ITEM CODE It DIMENSIONII ITEM LJ [BLAKJ[GALVJ[AB j jGIfl 3/8" 1M45B0303 1M4580303G 0.80 0.80 0.16 A 1/2" 1M45B0404 1M45B0404G 0.88 0.88 0.22 3/4" 1M45B0505 1M45B0505G 0.98 0.98 0.37 1" 1M45B0606 1M45B0606G 1.12 1.12 0.54 11/4" 1M45B0707 1M45B0707G 1.29 1.29 0.86 1 1/2" 1M45B0808 1M45B0808G 1.43 1.43 1.13 2" 1M45B0909 1M45B0909G 1.68 1.68 1.79 2 1/2" 1M45131010 1M4513101OG 1.95 1.95 2.78 UL ' 1M45B1111 1M45B1111G 2.17 2.17 4.48 I LISTED 1M45B1212 1M45B1212G 2.61 2.61 7.40 Description L 1 Malleable Thredet9O I iTEM CODE 11 DIMENSI(JN] ITEM GALV A JEB i WEIGHT _WE_]FM_ j[ 3/8" 1M90S0303 1M90S0303G 0.80 1.00 0.17 1/2" 1M90S0404 1M90S0404G 0.88 1.13 0.24 3/4 1M90S0505 1M90S0505G 1.00 1.31 0.41 .1 / 1M90S0606 1M90S0606G 1.23 1.44 0.62 / ( 11/4" 1M90S0707 1M90S0707G 1.31 1.69 1.09 I 11/2" 1M90S0808 1M90S0808G 1.44 1.88 1.44 1M90S0909 1M90S0909G 1.69 2.25 2.85 - A-i LISTED - Description I NUM t ITEM CUDE 1 HEM LLii 1ACKJLGAL'LJ_WEKHT[ Malleable Hex Nut 1/2" 1MLN04 1MLN04G 0.12 3/4" 1MLN05 1MLN05G 0.22 /1 1MLN06 1MLN06G 0.38 \ I ) 1 1 1/4" 1MLN07 1MLN07G 0.58 @ 1 1/2" : 0.73 :: 1.13 LISTED www.sigmaco.com - _Malleable Threaded FiJpgs Description I Malleable' j F NOM M I DI I ITE CODE IMENSTQNI1f ITEM 1 [ g[1jçJ[ AW ]LA1[ 1E[GIfT1 1/2" X 3/8" 1M90R0403 1M90R0403G 1.00 1.06 0.22 B 3/4" X 1/2" 1M90R0504 1M90R0504G 1.19 1.25 0.38 1" X 1/2" 1M90R0604 1M90R0604G 1.25 1.38 0.46 X 3/4" 1M90R0605 1M90R0605G 1.38 1.44 0.56 7 - 1 1/4" X 1/2" 1M90R0704 1M90R0704G 1.38 1.56 0.61 I A 1 1/4" X 3/4" 1M90R0705 1M90R0705G 1.44 1.63 0.71 / - 1 1/4" X 1" 1M90R0706 1M90R0706G 1.44 1.66 1.15 / 1 1/2" X 1/2" 1M90R0804 1M90R0804G 1.41 1.66 1.15 L 1 1/2" X 3/4" 1M90R0805 1M90R0805G 1.50 1.75 1.08 11/2" X 1" 1M90R0806 1M90R0806G 1.63 1.81 1.02 UL 11/2" X 1/4" 1M90R0807 1M90R0807G 1.81 1.88 1.17 LISTED 2" X 1/2" 1M90R0904 1M90R0904G 1.49 1.88 1.30 X 3/4" 1 M90R0905 1 M90R0905G 1.63 2.00 1.30 2"X 1" 1M90R0906 1M90R0906G 1.75 2.00 1.35 2" X 1 1/4" 1M90R0907 1M90R0907G 1.88 2.13 1.53 2" X 1 1/2" 1M90R0908 1M90R0908G 2.00 2.13 1.75 Description I Malleable Threaded Tee 14'hl IuI:1ts(.]ir: IIJIL'l II' 4I I Oil KNOIA I 11111111=21_- 1/4" 1MT020202 1MT020202G 0.81 0.15 iiII I 3/8" 1MT030303 1M1030303G 0.94 0.23 A 1/2" 1 MT040404 1 MT040404G 1.13 0.41 I 3/4" 1MT050505 1 MT060606 1MT050505G 1.31 0.60 1" 1MT060606G 1.50 0.90 I I 1 1/4" 1M1070707 1MT070707G 1.75 1.31 J L 11/2" 1M1080808 1MT080808G 1.94 1.73 2" 1MT090909 1MT090909G 2.25 2.52 U 2 1/2" 1MT101010 1MT101010G 2.69 4.90 3" 1MT111111 1MT111111G 3.06 7.13 LISTED 4" 1MT121212 1MT121212G 3.81 11.32 Description L I I ITEM flE 111MM.. II 1TE F95 P T771 Fu_ IJLJLWELQRT LMalleable %Z9 I Threaded Cross A--A- 1/2" 1MX04 1MX04G 1.12 0.42 3/4" 1MX05 IMXOSG 1.13 0.69 - -A 1" 1MX06 1MX06G 1.50 1.12 1 1/4" 1MX07 1MX07G 1.75 1.44 - 11/2" 1MX08 1MX08G 1.94 1.98 2" 1MX09 1MX09G 2.25 3.30 U 2 1/2" 1MX10 1MX10G 2.70 5.90 r - A 3" 1MX11 1MX11G 3.08 13.50 I LISTED www.sigmaco.com Malleable Reducing Tee rm- Malleable_Threaded Fittings Description I NOM I ITEM GUIJh 11 luMEN- 1 EM JLAJ[.QAJ5LJLA 1L it .!. 1/2" X 1/2" X 3/8" 1M1040403 1MT040403G 1.06 1.06 1.06 0.30 3/4" X 1/2" X 1/2" 1M1050404 1MT050404G 1.08 1.08 1.09 0.38 3/4" X 1/2" X 3/4" 1M1050405 1MT050405G 1.11 1.11 1.13 0.46 3/4" X 3/4" X 1/2" 1MT050504 1MT050504G 1.19 1.19 1.25 0.47 1 X 1/2 X 1/2 1 MT060404 1MT060404GI 1.21 1.21 1.30 0.58 1 3/4" X 1/2" 1MT060504 1MT060504G 1.22 1.22 1.32 0.59 1 X 3/4 X 3/4 1MT060505 1MT060505G 1.23 1.23 1.33 1.59 IX I" X 1/2" 1M1060604 1MT060604G 1.25 1.25 1.38 0.70 1 X 1 X 3/4 1MT060605 1MT060605G 1.38 1.38 1.44 0.82 1 1/4" X 1" X 1" 1MT070606 1MT070606G 1.56 1.56 1.69 1.10 1 1/4" X 11/4" X 1/2" 1MT070704 1M1070704G 1.38 1.38 1.56 0.98 1 1/4" X 1 1/4" x 3/4" 1MT070705 1MT070705G 1.40 1.40 1.60 0.94 1 1/4" X 1/4"X 1" 1MT0707061MT070706G 1.56 1.56 1.69 1.20 11/2" X 1/4" X " 1MT080706 1MT080706G 1.63 1.63 1.81 1.30 U1 1 1/2"X 1 1/2"X 1/2" 1 MT080804 1 MT080804G' 1.44 , 1.44 1.69 1.19 11/2" X 1 1/2" x 3/4" 1M1080805 1MT080805G 1.50 1.50 1.75 1.30 LISTED 11/2" X 1/2"X 1" 1M10808061MT080806G 1.63 1.63 1.81 1.45 11/2" X 1/2" X 1/4" 1M1080807 1M1080807G 1.81 1.81 1.88 1.52 2 X2 x 1/2 1MT090904 1MT090904G 150 1.50 188 1.65 2" X 2" x 3/4" 1 MT090905 1 MT090905G 1.63 1.63 2.00 1.87 2"X2"X 1" - 1M1090906 1M1090906G 1.75 1.75 2.00 1.76 2" X 2" X 1 1/4" 1MT090907 1MT090907G 1.88 1.88 2.13 2.35 2" X 2"X 1 1/2" 1MT090908 1MT090908G 2.00 2.00 : 2.19 2.55 2 1/2" X 2 1/2" X 1" 1MT101006 1MT101006G 1.88 1.88 2.38 2.85 2 1/2"X2 1/2"X 1 1/4"1MT1010071MT101007G.] 2.06 2.06 2.44 3.36 2 1/2 X 2 1/2 X 1 1/2 1MT101008 1MT101008G 2.19 2.19 2.50 3.46 21/2 X 2 1 /T X2 1MT101009 1MT101009G 238 238 262 365 3" X 3" X 1/2" 1MT111104 IMT111104G 1.76 1.76 2.52 4.03 3 X3 X3/4 1M1111105 1MT111105G 188 188 163 403 3" X 3" X 1" 1MT111106 1MT111I06G 2.00 2.00 2.62 4.13 3 )(3 )(11/4 1M1111107 1MT1111076 219 ii 219 275 450 3" X 3" X 11/2" 1MT111108 1MT111108G 2.31 2.31 2.81 5.18 3" X 3" X 2" 1MT111109 : 1MT111109G 2.50 ,, 2.50 2.88 ' 5.70 3" X 3" X 1 1/2" 1MT111110 1MT111110G 2.57 2.57 2.89 5.00 4 X4 X11/4 1MT121207 1M1121207G 239 239 326 747 4" X4"X 11/2" 1MT121208 1MT111208G 2.51 2.51 3.32 7.47 4" X 4" X 2" 1MT121209 1MT121209G 2.75 2.75 3.44 8.39 4" X 4" X 2 1/2" 1M1121210 1MT12121OG 2.75 2.75 3.44 7.70 4" X 4" X 3" 1MT121211 1MT121211G 3.31 ji 3.31 1 3.63 8.93 Description [ Malleable Cap LISTED NUM F ITEM CODE II ITEM 1 I cAcJELvjLwEIQBLi 1/2" 1MK04 1MKO4G - 0.14 3/4" 1MK05 1MK05G 0.21 1" 1MK06 1MK06G 0.37 1 1/4" 1MK07 1MK07G 0.58 1 1/2" 1MK08 1MK08G 0.74 2" 1MK09 1MK09G 0.94 2 1/2" 1MK10 1MK10G 1.60 1MK11 1MK11G 2.79 1MK12 1MK12G . 3.66 www.sigmaco.com Malleable_mreadewttings I LISTED Description F Malleable Coupling Description L Il IT.McEJE 11U1M1 1 ITEM SIZE LACKI GALV ii A J WE1RT 3/8" 1MCP0303 1MCP0303G 1.18 0.13 1/2" 1MCP0404 1MCP0404G 1.31 0.20 3/4" 1MCP0505 1MCP0505G 1.50 0.30 1" 1MCP0606 1MCP0606G 1.69 0.48 1 1/4" 1MCP0707 1MCP0707G 1.93 0.75 1 1/2" 1MCP0808 1MCP0808G 2.13 1.00 2" 1MCP0909 1MCP0909G 2.50 1.45 2 1/2" 1MCP1010 1MCP1010G 2.88 2.40 1MCP1111 1MCP1111G 3.19 3.30 4" 1MCP1212 1MCP1212G 3.69 5.72 Malleable Reducing Coupling LISTED Description L I Malleable Floor Flange I NOM SIZE-7'JThM CODE 111MM. 1 ITEM .1 BLACK JL_GLVr . IL -T --j I WE1QHT 1/2" X 3/8" 1MCR0403 1MCR0403G 0.17 0.17 3/4" X 1/2" 1MCR0504 1MCR0504G 0.27 0.27 1" X 1/2" 1MCR0604 1MCR0604G 0.39 0.39 1" X 3/4" 1MCR0605 1MCR0605G 0.43 0.43 1 1/4" X 1/2" 1MCR0704 1MCR0704G 0.61 0.61 1 1/4"X314" 1MCR0705 1MCR0705G 0.64 0.64 1 1/4" X 1" 1MCR0706 1MCR0706G 0.68 0.68 1 1/2" X 1/2" IMCR0804 IMCR0804G 0.78 0.78 1 1/2" X 3/4" 1MCR0805 1MCR0805G 0.88 0.88 1 1/2" X 1" 1MCR0806 1MCR0806G 0.88 0.88 11/2" X 1/4" 1MCR0807 1MCR0807G 0.90 0.90 2" X 1/2" 1MCR0904 1MCR0904G 1.15 1.15 2" X 3/4" 1 MCRO9O5 1 MCRO905G 1.34 1.34 2" X 1" 1 MCR0906 1 MCR0906G 1.40 1.40 2" X 1 1/4" 1MCRO907 1MCR0907G 1.53 1.53 2" X 1/2" 1MCRO908 1MCR0908G 1.55 1.55 2 1/2" X 1 1/4" 1MCR1007 1MCR1007G 2.09 2.09 2 1/2" X 1 1/2" 1MCR1008 1MCR1008G 2.09 2.09 2 1/2" X 2" . 1MCR1009 .. 1MCR1009G . 2.51 2.51 3" X 1 1/4" 1MCR1107 1MCR1107G 2.99 2.99 3" X 1 1/2" 1MCR1108 1MCR1108G 3.30 3.30 3"X2" 1MCR1109 1MCR1109G 3.25 3.25 X2 1/2" 1MCR1110 1MCR1110G 3.29 3.29 X 1 1/2" 1MCR1208 1MCR1208G 4.90 4.90 4" X 2" 1MCR1209 1MCR1209G 5.10 5.10 4" X 2 1/2" 1MCR1210 1MCR121OG 6.55 6.55 4"X3" 1MCR1211 1MCR1211G 4.04 4.04 FIqUff-I E ITEM GUilE lIDIMENSIUNilI ITEM LIZ. ii i[. LJL. JLWEIGFJT 1/2" IMFF04 1MFF04G 3.50 2.50 0.56 3/4" 1MFF05 1MFF05G 3.50 2.50 0.60 1MFF06 1MFF06G 4.00 3.0 0.84 1 1/4" 1MFF07 1MFF07G 4.00 3.00 0.90 11/2" 1MFF08 1MFF08G 4.50 3.50 1.20 1MFF09 IMFF09G 5.50 4.25 2.03 ___A LISTED www.sigmaco.com Malleable_Threaded Fittings___________________ Description I Malleable Plug ISrI'l Iiits.iiiI ri ILft I3-W I'LiI 3/8" 1MPLG03 1MPLG03G 0.06 1/2" 1MPLG04 1MPLG04G 0.10 3/4" 1MPLGO5 1MPLG05G 0.17 1MPLG06 1MPLG06G 0.28 1 1/4" 1MPLG07 1MPLG07G 0.44 1 1/2" 1MPLG08 1MPLG08G 0.62 1MPLGO9 1MPLG09G 0.91 UL 2 1/2" 1MPLG10 1MPLG10G 1.05 LISTED " 1MPLG11 1MPLG11G 1.70 4" 1MPLG12 1MPLG12G 3.00 Description I Il dIII(S]I] Malleable Bushings I- 1/2' X 1/4" 1MBSH0402 1MBSH0402G 0.06 1/2" X 3/8" 1MBSH0403 1MBSH0403G 0.05 3/4" X 1/2" 1MBSH0504 1MBSH0504G 0.11 1" X 1/2" 1MBSH0604 1MBSH0604G 0.21 1" X 3/4" 1MBSH0605 1MBSH0605G 0.17 1 1/4" X 1/2" IMBSH0704 1MBSH0704G 0.34 1 1/4" X 3/4" 1MBSH0705 1MBSH0705G 0.31 1 1/4" X 1" 1MBSH0706 1MBSH0706G 0.26 UL 1 1/2" X 1/2" 1MBSH0804: 1MBSH0804G 0.48 ISTED 1 1/2" X 3/4" 1MBSH0805 1MBSH0805G 0.48 1 1/2" X 1" 1MBSH0806 1MBSH0806G 0.43 1 1/2" X 1 1/4" 1MBSH0807 1MBSH0807G 0.30 2"X 1/2" 1MBSH0904 1MBSH0904G 0.65 2" X 3/4" 1MBSH0905 1MBSH0905G 0.83 2" X 1" 1MBSH0906 IMBSH0906G 0.78 2" X 1 1/4" 1MBSH0907 • 1MBSH0907G 0.73 2" X 1 1/2" 1MBSH0908 1MBSH0908G 0.60 2 1/2" X 1 1/4" 1MBSH1007 1MBSH1007G 1.30 2 1/2" X 1 1/2" 1MBSH1008 1MBSH1008G 1.20 2 1/2" X 2" 1MBSH1009 1MBSH1009G 0.90 3" X 1 1/4" 1MBSH1107 1MBSH1107G 2.50 3" X 1 1/2" 1MBSH1108 1MBSH1108G 2.30 3"X2" 1MBSH1109 1MBSH1109G 2.00 3"X2 1/2" 1MBSH1110 1MBSH1110G 1.60 4" X 1 1/4" 1MBSH1207 IMBSH1207G 3.20 4" X 1 1/2" 1MBSH1208 1MBSH1208G 3.30 4" X2" 1MBSH1209 1MBSH1209G 3.10 4" X 2 1/2" 1MBSH1210 1MBSH121OG 3.80 4"X3" 1MBSH1211 IMBSH1211G 3.00 www.sigmaco.com Malleable Threaded Fittings Description I I ITEMGUDE IIDIM. I ITEM Malleable Union SIZE BLACKj[ AW7 -A7 F t WIFtT 1/4" 1MUN02 1MUN02G 1.81 0.45 A 3/8" 1MUN03 1MUN03G 1.81 0.42 1/2" 1MUN04 1MUN04G 1.94 0.44 3/4" 1MUN05 1MUN05G 2.06 0.60 1MUN06 IMUN06G 2.44 0.91 1 1/4" 1MUN07 1MUN07G 2.63 1.45 11/2" 1MUN08 1MUN08G 2.75 1.69 1MUN09 1MUN09G 2.94 2.46 1MUN11 1MUN11G 3.63 4.95 LISTED 4" 1MUN12 1MUN12G 3.75 8.75 Description 1 77771 ______________________________________ NUM SIZE I 1TEMcQflE 1IDIM Il ITEM [BLACK J[ GAIN JL_ ILWEIGHI Malleable Union wl Brass Seat 1/4" 1MUNBS02 1MUNBS02G 1.81 0.45 A 3/8" IMUNBS03 IMUNBS03G 1.81 0.42 I 1/2" 1MUNBS04 1MUNBS04G 1.94 0.44 3/4" 1MUNBS05 1MUNBS05G 2.06 0.60 1MuNBS06 IMUNBS06G 2.44 0.91 I 1 1/4" 1MUNBS07 1MUNBSO7G 2.63 1.45 I 1 11/2" :i 1MUNBS08 1MUNBS08G 2.75 1.69 Ui. 1MUNBS09 1MUNBS09G 2.94 2.46 L " 1MUNBS11 1MUNBS11G 3.63 4.95 LISTED 4" 1MUNBS12 1MUNBSI2G 3.75 8.75 Description I I Malleable Extension 'iI II$II(11lL lIi1I www.sigmaco.com IOUWD© kMrj TThIr@x]©Jij_E-~ftnucg . E O Notice: D.I. Fittings have higher tensile strength then fl D.I. Threaded fittings are UL, cUL listed and Factory Mutual that of steel pipe, over tightening can cause damage approved for 500ps1 servce. D.I. Per ASTM A 536 grade 65-45- to pipe threads which may cause leakage. D.I. Fitting 12. Dimensions conform to ANSI 1316.3 Class 150. Threads are should be tightened three turns beyound hand tighten, NPT perANSI/ASME 131.20.1 no more than four turns. Description I D. 1. 90 Degreed Elbow ceus A91 UMD 7 _ NOM I1TEMGOUE1FULMENSIORf ITEM I SIZE 1 AJ[ B JIEEGJ1ii 1D90B0606 1.50 1.50 0.62 1 1/4" 1D90B0707 1.75 1.75 0.90 1 1/2" 1D90B0808 1.94 1.94 1.20 2" 1D90B0909 2.25 2.25 1.85 Description I D. 1. Straight Tee A A B[ftJ fJ c USTED Lh [ VThMCODEILIJIMENSIØNII ITEM I NOM L BLACI IL J[L,IH 1DT060606 1.50 1.50 0.85 11/4" 1DT070707 1.75 1.75 1.22 11/2" . 1D1080808 1.94 1.94 1.55 1DT090909 2.25 2.25 2.45 Description I D.I. Coupling USTED A ___ NOM SIZE IIThM COu1i DIMVV I iTEM I i ___ 1DCP0606 1.50 0.85 11/4" 1DCP0707 1.75 1.22 11/2" 1DCP0808 1.94 1.55 1DCP0909 2.25 2.45 Description I D. 1. Red. 90 Deg .Elbow _ iT)UMD NOM SIZE 1iFM QPF1LIJIMENSIUN1 [.AcIc]L ir 1 X1/2" . 1D90R0604 1.26 1.36 0.44 I X3/4" 1D90R0605 1.37 1.45 0.52 1 1/4X 1/2" 1D90R0704 1.34 1.53 0.64 . 1 1/4 X 3/4" 11390R0705 1.45 1.62 0.72 .11/4" X 1" 1D90R0706 1.58 1.67 0.75 1 1/2" X 1" 1D90R0806 1.65 1.80 0.92 V 11/2" X 1/4". V 1D90R0807 1.82 1.88 1.08 V 2" X 1/2" 1D90R0904 1.49 1.88 1.08 V 2" X 3/4" 1 D90R0905 1.60 V 1.97 1.24 2" X 1" 1 D90R0906 1.73 2.02 1.40 V 2" Xl 1/4" 1090R0907 1.90 2.10 1.52 2" X 1/2" 1D90R0908 2.02 2.16 1.65 Description I D. Reducing Coupling _________ I 1EITEM ODE1I DJM. II ITEM 1 us tNOMSIZEJLBLACKJLA c® 1 X 1/2" 1DCR0604 1.69 0.39 1 X314" 1DCR0605 1.69 0.53 Description F I D.I. 45 Degreed Elbow USTED NOM SIZE 1IITEM COD1FThME NSItJN1I ITEM 1 F ULJ[AL fl1 1D45B0606 1.12 1.12 0.46 11/4" 1D45B0707 1.29 1.29 0.73 1 1/2" 11345130808 1.43 1.43 0.92 1D45B0909 1.68 1.68 1.50 www.sigmaco.com Ductile Iron Threaded Fithngs Description I D. 1. Bushing C NEW C&S -IB A LIM OUTSIDE HEAD INSIDE HEAD FM-s7lzE...-,i ]PIN FsTYLi[I 1 X112" 1D8US0604 0.75 0.25 1.42 OUT 0.22 1 X3/4" 1DBUS0605 0.75 0.25 1.42 OUT 0.17 11/4" X 1" 1 DBUSO7O6 0.80 0.28 1.76 OUT 1.28 1 1/2" X 1" 1DBUS0806 0.83 0.31 2.00 OUT 0.44 1 1/2"X1 1/4" IDBUS0807 0.83 0.31 , 2.00 V OUT 0.30 2" X 1" 1DBUS0906 0.88 0.41 1.95 IN 0.66 2" X1 1/4" 1DBUS0907 0.88 0.34 2.48 OUT 0.72 2" X 1 1/2" 1DBUS0908 0.88 0.34 2.48 OUT 0.61 Description L I D. 1. Cross 'A Ill leiA USTED F~MEi BLAJ[_AJ[S IWEIGF! , 1DX0606 1.50 1.50 , 0.98 11/4" 1DX0707 1.75 1.75 , 1.50 1 1/2' 1DX0808 , 1.94 , 1.94 1.90 1DX0909 2.25 2.25 2.95 1 1/4" X 1" 1DX0706 1.58 1.67 , 1.27 11/2" X 1" , 1 DX0806 1.65 1.80 1.45 2" X 1" 1DX0906 1.73 2.02 , 2.10 Description I D. 1. Cap . ......... LI A , cuS NOM SIZE 1F{EM COtJE1I UIM II ITEM 1 IDK06 1.16 , 0.32 1 1/4" 1DK07 1.28 0.43 1 1/2" 1DK08 1.33 0.60 1DK09 1.45 0.91 www.sigmaco.com Description t DI. Reducing Tee umn 1111EMc00E1FflIMENSION I ITEMNOM SIZE ['B!i Lk J. IL JvEIGH 1" x lx 1/2" 1D1060604 1.26 1.26 1.36 0.64 1" x 1" x 3/4" 1DT060605 1.37 1.37 145 0.73 1" x 1/2" x 1" V 10T060406 1.50 ' 1.36 1.50 0.71 1" x 3/4" x1" 1DT060506 1.50 1.45 1.50 0.76 1" x 1" x 1/4" 10T060607 167 1.67 1.58 0.98 1" x 1" x 11/2" 1DT060608 180 1.80 1.65 1.16 11/4" x " x 1/2" 10T070604 134 1.26 1.53 0.82 1 1/4" x 1" x 3/4" 1DT070605 1.45 1.37 1.62 0.90 11/4" xix 1" 1DT070606 1.58 1.50 1.67 1.00 11/4" x 1" x 11/4" 1DT070607 1.75 1.67 1.75 1.08 11/4" xix 11/2" 1DT070608 1.88 1.88 182 1.42 1 1/4" x 1 1/4" x 1/2" 1DT070704 134 1.34 1.53 0.86 11/4" x 1/4" x 3/4" 1D1070705 1.45 , 1.45 1.62 0.92 11/4" x 1 1/4" x 1" 101070706 1.58 1.58 167 0.95 11/4" x 1/4" x 1" 1D1070708 1.88 1.88 1.82 1.45 1 1/4"x 11/4" x2" 1DT070709 2.10 2.10 1.90 1.75 1 1/2" x 1" x 1/2" 10T080604 1.41 1.34 ' 1.66 0.95 1 1/2" x 1" x 3/4" 10T080605 1.52 1.37 1.75 1.14 11/2" xl" x 1" 1DT080606 165 ' 1.50 1.80 1.17 11/2" x 1" x 11/4" 1DT080607 1.82 1.67 1.88 1.34 11/2" x1" x 1/2" 1D1080608 V 1.94 1.80 1.94 1.45 11/2" x 1/4" x 1/2" 1DT080704 1.41 1.34 1.66 1.05 11/2" x 1/4" x3/4" 10T080705 152 1.45 1.75 1.15 11/2" x 1/4" x " 1DT080706 165 1.58 1.80 1.25 1 1/2"x 1 1/4"x2" 1DT080709 216 2.10 2.02 1.90 11/2" x 1/2" x 1/2" 1DT080804 1.41 1.41 1.16 1.15 1 112"x1 1/2"x3/4" 1DT080805 1.52 , 1.52 1.75 1.24 11/2" x 1/2" x " 1DT080806 1.65 1.65 1.80 1.30 11/2" x 11/2" x 1" 10T080807 182 1.82 1.88 1.48 1 1/2" x 1 1/2" x 2" 1D1080809 2.16 2.16 2.02 1.98 2" x 1" x 2" 10T090609 225 2.02 ' 225 2.15 2" xi 1/4" x2" 1DT090709 2.25 2.10 2.25 2.30 2" x 11/2" x 1/2" 10T090804 1.49 1.41 188 1.50 2" x 1/2" x 3/4" 1DT090805 1.60 1.52 1.97 1.62 2" x 11/2" x 1" , 10T090806 1.73 ' 165 , 2.02 1.64 2" x 11/2" x 1/4" 1D1090807 1.90 1.82 2.10 1.80 2" x 1 1/2" x 1 1/2" 1D1090808 202 1.94 2.16 2.00 2" x 1 1/2" x 2" 10T090809 2.25 2.16 2.25 2.35 2" x 2" x 1/2" 10T090904 1.49 1.49 1.88 1.60 2" x 2" x 3/4" 1 DT090905 1.60 1.60 197 1.68 2" x 2" x1" 1 DT090906 1.73 1.73 2.02 1.85 2" x2" x 1/4" 101090907 1.90 1.90 2.10 2.04 2" x 2" x 1 1/2" 1DT090908 202 2.02 2.16 2.18 2" x 2" x 2 1/2" 10T090910 2.60 2.60 2.39 3.61 2 1/2" x 2" x 3/4" 101100905 174 1.60 2.32 2.28 oTOWj IN F fcnj El Cl. Threaded fittings are UL, cUL listed and Factory Mutual approved for 300psi servce. Gray iron per ASTM 126 class B. Dimensions conform to ANSI B 16.4 Class 125 except plugs conform to ASME B 16,14. Threads are NPT perANSI/ASME B1.20.1. Description L I C. 1. 90 Degreed Elbow B Description E 1 C I Reducing 90 Degreed Elbow B /r1 A I I NOM S ILTEM CODJ[DIMFNSIøN1I ITEM JLAJL ts J1ELGU. 1C90B0606 1.50 1.50 0.85 11/4" 1C90B0707 1.75 1.75 1.22 11/2" 1C90B0808 1.94 1.94 1.55 1C90B0909 2.25 2.25 2.45 2 1/2" 1C9061010 2.70 2.70 4.80 Description I C. 1. Straight Tee A A Fr---fl J1US NOM SIZE ITEM --L LANK IL A J[ ]VE1GR 1CT060606 1.50 1.50 0.85 11/4" 1CT070707 1.75 1.75 1.22 11/2" 1CT080808 1.94 1.94 1.55 1CT090909 2.25 2.25 2.45 2 1/2" 1CT101010 2.70 2.70 6.39 Description 1 1 C. 1. Reducing Coupling E 1 H LNOMTIZE]I UIM.I ITEM 1 LLcK1 L J IN11i1d 1 X 1/2" 1CCR0604 1.69 0.62 1 X 3/4" 1CCR0605 1.69 0.69 NOM SIZE ILTEM oDII 1 X1/2" 1C90R0604 1 X 3/4" 1 C90R0605 1 1/4X1/2" 1C90R0704 1 1/4 X 3/4" 1C90R0705 1 1/4" X 1" . 1C90R0706 1 1/2" X 1/2" 1C90R0804 1112" X 3/4" 1C90R0805 1 1/2" X 1" 1C90R0806 1 1/2" X 1 1/4" 2" X 1/2" - 1C90R0807 1C90R0904 2" X 3/4" . 1C90R0905 2" X 1" 1C90R0906 2" Xl 1/4" .. 1C90R0907 2" X 1 1/2" 1C90R0908 Description F 1 C. 1. 45 Degreed Elbow F IDTM L SIZE ]Lc!cILJc i I 1C45B0606 1.12 1.12 1 1/4" 1C45B0707 1 1/2" 1C4560808 1C45B0909 www.sigmaco.com Description I C.I. Plugs L1 ru - -.-. ILTFI! NOM SIZE -I ITEM CODE1I D1M I ITEM LA.CK1[. A jIyEQftj 1/2" 1CPLG0404 0.94 0.10 3/4" 1CPLG0505 1.07 0.17 1CPLG0606 1.25 0.28 1 1/4" 1CPLG0707 1.36 0.44 1 1/2" .. 1CPLG0808 1.45 0.62 2" 1CPLG0909 1.56 0.91 Description I C. 1. Cross A A LIOM SIZIITEM CODI1 DIMENSIONif iTEM i1BLAcK IL}.L ]EB1IVEJG}1 1CX0606 1.50 1.50 1.54 1 1/4" 1CX0707 1.75 1.75 2.40 1 1/2" 1CX0808 1.94 1.94 3.10 1CX0909 2.25 2.25 4.00 1 1/4" X 1" 1CX0706 1.58 1.67 2.05 11/2" X 1" 1CX0806 1.65 1.80 2.40 2" X 1" 1CX0906 1.73 2.02 2.75 iron Threaded Rthngs__________________ Description I C. 1. Reducing Tee A B r USTO H NOM SIZE i IITEMCODEIL DIMENSION Ij ITEM 1" x 1"x 1/2" 1CT060604 1.26 1.26 1.36 0.95 I" x 1" x 3/4" 1CT060605 1.37 1.37 1.45 1.10 lx 1/2" x 1" 1C1060406 1.50 1.36 1.50 1.08 x 3/4" x1" 1CT060506 1.50 1.45 1.50 1.18 lx lx 11/4" 1C1060607 1.67 1.67 1.58 1.52 lx 1" x 11/2" 1C1060608 1.80 1.80 1.65 1.73 11/4" x lx 1/2" 1CT070604 1.34 1.26 1.53 1.17 11/4" x 1" x 3/4" 1C1070605 1.45 1.37 1.62 1.38 11/4" x 1" x 1" 1CT070606 1.58 1.50 1.57 1.47 11/4" x 1" x 11/4" 1CT070607 1.75 1.67 1.75 1.80 1 1/4" x 1" x 1 1/2" 1C1070608 1.88 1.80 1.82 2.05 11/4" x 11/4" x 1/2" 1CT070704 1.34 1.34 1.53 1.37 11/4" x 11/4" x 3/4" 1C1070705 1.45 1.45 1.62 1.54 11/4" x 11/4" x 1" 1CT070706 1.58 1.58 1.67 1.65 1 1/4" x 1 1/4" x 1/2" 1CT070708 1.88 1.88 1.82 2.21 11/4" x 1/4" x2" 1CT070709 2.10 2.10 1.90 2.55 11/2" x I" x 1/2" 1CT080604 1.41 1.34 1.66 1.41 1 1/2"x1"x3/4" 1CT080605 1.52 1.37 1.75 1.65 11/2" x 1" x 1" 1C1080606 1.65 1.50 1.80 1.65 1 1/2" x 1" x 1 1/4" 1CT080607 1.82 1.67 1.88 2.00 11/2" x 1" x 11/2" 1C1080608 1.94 1.80 1.94 2.30 1 1/2" x 1 1/4" x 1/2" 1C1080704 1.41 1.34 1.66 1.58 11/2" x 11/4" x 3/4" 1CT080705 1.52 1.45 1.75 1.72 11/2" x 11/4" x 1" 1CT080706 1.65 1.58 1.80 1.85 11/2"x1 1/4"x1 1/4" 1C1080707 1.82 1.75 1.88 2.22 11/2"x1 1/4"x1 1/2" 1CT080708 1.94 1.88 1.94 2.45 1 1/2" x 1 1/4" x 2" 1CT080709 2.16 2.10 2.02 2.80 11/2" x 11/2" x 1/2" 1CT080804 1.41 1.41 1.66 1.76 1 1/2" x 1 1/2" x 3/4" 1C1080805 1.52 1.52 1.75 1.87 11/2" x 11/2" x 1" 1CT080806 1.65 1.65 1.80 1.94 1 1/2"x1 1/2"x1 1/4' 1CT080807 1.82 1.82 1.88 2.29 1 1/2" x 1 1/2" x 2" 1CT080809 2.16 2.16 2.02 3.28 x 1" x 2" 1CT090609 2.25 2.02 2.25 3.40 2" x 1 1/4" x 2" 1C1090709 2.25 2.10 2.25 2.80 2" x 1 1/2" x 1/2" 1CT090804 1.49 1.41 1.88 2.09 2" x 1 1/2" x 3/4" 1C1090805 1.60 1.52 1.97 2.40 2" x 1 1/2" x 1" 1CT090806 1.73 1.65 2.02 2.54 2" x 11/2" x 1/4" 1CT090807 1.90 1.82 2.10 2.85 2" x 1 1/2" x 1 1/2" 1CT090808 1.49 1.41 1.88 2.24 2" x 1 1/2" x 2" 1CT090809 2.25 2.16 2.25 3.75 2" x 2" x 1/2" 1CT090904 1.49 1.49 1.88 2.60 2" x2"x3/4" 1CT090905 1.60 1.60 1.97 2.71 2" x 2" xl" 1CT090906 1.73 1.73 2.02 2.97 2" x 2" x 1 1/4" 1CT090907 1.90 1.90 2.10 3.32 2" x 2" x 1 1/2" 1CT090908 2.02 2.02 2.16 3.72 2" x 2" x 2 1/2" 1CT090910 2.60 2.60 2.39 5.10 www.sigmaco.com r gm Poo [~L P 11LX [D© Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME B1.20.1 Description L Black Steel NOMINAL SIZE FL ENGTH 1!4"J[ 3/8" II 1/2" J[ 34" j[ 17JJ 14 J[iI/2" 11 7-2-771 CLOSE 1NBO101 1NB0201 1NB0301 1NB0401 1NB0501 1NB0601 1NB0701 1NBO801 1NB0901 1 1/2" 1NB0108 1NB0208 1NB0308 1NB0408 1NB0508 NA NA NA NA 2" 1NBO109 1NB0209 1NB0309 1NB0409 1NB0509 1NB0609 1NB0709 1N80809 - NA 2 1/2" 1NBO110 1NB02010 INB0310 1NB0410 1NB0510 1F'JB0610 1NB0710 1NB0810 1NB0910 3" 1NBO111 1NB0211 1NB0311 1NB0411 1NB0511 1NBO611 .. 1NB0711 1NB0811 1NB0911 3 1/2" 1NB0111-5 1NB0211-5 1NB0311-5 1NB0411-5 1NB0511-5 1NBO611-5 1NB0711-5 1NB0811-5 1NB0911-5 4" 1NBO112 1NB0212 1NB0312 1NB0412 1NB0512 1NB0612 1NB0712 1NB0812 1NB0912 4 1/2" 1NBO112-5 1NB0212-5 1NB0312-5 1NB0412-5 1NB0512-5 1NB0612-5 1NB0712-5 1NB0812-5 1NB0912-5 5" 1NBO113 j 1NB0213 . 1NB0313 1NB0413 1NB0513 1NB0613 1NB0713 1NB0813 1NB0913 5 1/2" 1NBO113-5 1NB0213-5 1NB0313-5 1NB0413-5 1NB0513-5 1NB0613-5 1NB0713-5 1NB0813-5 1NB0913-5 6" 1NBO114 1NB0214 1NB0314 1NB0414 1NB0514 1NB0614 1NB0714 1NB0814 1NB0914 6 1/2" 1NBO114-5 1NB0214 -5 1NB0314-5 1NB0414-5 1NB0514-5 1NB0614-5 1NB0714-5 1NB0814-5 1NB0914-5 7" NA NA NA NA NA 1NB06147 1NB07147 1NB08147 1NB09147 7 1/2" NA NA NA NA NA 1NB06147-5 1NB07147-51NB08147-5 1NB09147-5 8" 1N80115 1NB0215 1NB0315 1NB0415 1NB0515 1NB0615 1NB0715 1NB0815 1NB0915 8 1/2" NA NA NA NA NA 1NB0615 -5 1NB0715-5 1NB0815-5 1NB0915-5 9" 1NBO116 1NB0216 . 1N80316 1NB0416 1NB0516 1NJB0616 1N80716 1NB0816 1NB0916 9 1/2" NA NA NA NA NA 1NB0616 -5 - 1NB0716-5 1NB0816-5 1NB0916-5 INBO117 1NB0217 1NB0317 1NB0417 1NB0517 1NB0617 1NB0717 1NBO817 1NB0917 101/2" NA NA NA NA NA 1NB0617-5 1NB0717-5 1NB0817-5 1NB0917-5 1NBO118 1NB0218 1NB0318 1N80418 1NB0518 1NB0618 1NB0718 1NB0818 1NB0918 111/2" NA NA NA NA NA 1NB0618-5 1NB0718-5 1NB0818-5 1N80918-5 1NBO119 1NB0219 1NB0319 1NB0419 1NB0519 1NB0619 1NB0719 1NB0819 1NB0919 L NOMINAL SIZE FLE7NTTH]LZV2, CLOSE 1NB1001 1NBI101 1NB1201 1NB1401 1NB1011 1NB1111 NA NA 31/2" 1NB1011-5 1N81111-5 1NB1211-5 NA 1NB1012 1NB1112 1NB1212 NA 41/2" 1NB1012-5 1NB1112-5 1NB1212-5 NA INB1013 1NB1113 1NB1213 NA 51/2" 1NB1013-5 1NB1113-5 1NB1213-5 NA 1NB1014 1NB1114 1NB1214 1NB1414 1NB1015 1NB1115 1NB1215 1NB1415 1NB1016 1NB1116 1NB1216 1NB1416 1NB1017 1NB1117 1NB1217 1NB1417 - 1NB1018 1NB1118 1NB1218 1NB1418 1NB1019 1NB1119 1NB1219 1NB1419 www.sigmaco.com 00 I]i P 0~ I D WS G-andnon~mpd E Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME B1.20.1 Galvanized to spec. ASTM A 153- for zinc coating. Description [ Galvanized Steel NOMINAL .SIZE 118" 1NG0101 1NG0201 1NG0301 1NG040I 1NG0501 1NG0601 1NG0701 1NG0801 1NG0901 NA 1NG0201-1 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 1NG0108 1NG0208 1NG0308 1NG0408 1NG0508 NA NA NA NA 1NG0109 1NG0209 1NG0309 : 1NG0409 1NG0509 1NG0609 1NG0709 1NG0809 NA 1NG0110 1NG02010 1NG0310 1NG0410 1NG0510 1NG0610 1NG0710 1NG0810 1NG0910 1NG0111 1NG0211 1NGO311 1NG0411 1NG05I1 ING0611 1NG07I1 1NG0811 1NG0911 1NG0111-5 1NG02II-5 ING0311-5 1NG0411-5 1NGO51I-5 1NG0611-5 1NG0711-5 ING08I1-5 ING0911-5 1NG0112 1NG0212 1NG0312 1NG0412 1NG0512 1NG0612 1NG0712 1NG0812 1NG0912 1 NGO112-5 1 NG0212-5 1 NG0312-5 1 NG0412-5 1 NG0512-5 1 NG0612-5 1 NG0712-5 1 NG0812-5 1 NG0912-5 1NG0113 1NG0213 1NG0313 1N60413 1NG0513 1NG0613 1NG0713 1NG0813 1NG0913 1NG0113-5 1NG0213-5 1NG0313-5 1NG0413-5 1NG0513-5 1NG0613-5 1NG0713-5 1NG0813-5 1NG0913-5 1NGO114 1NG0214 1NG0314 1NG0414 1NG0514 1NG0614 1NG0714 1NG0814 1NG0914 1 NG0114-5 1 NG0214-5 1 NG0314-5 1 NG0414-5 1 NG0514-5 NG0614-5 1 1 NG0714-5 1 NG0814-5 1 NG0914-5 NA NA NA 1NG04147 NA 1NG06147 1NG07147 1NG08147 1NG09147 1NG0115 1NG0215 1NG0315 1NG0415 1NG0515 1NG0615 1NG0715 1NG0815 1NG0915 NA NA NA 1NG0415-5 NA NA NA NA NA 1NG0116 1NG0216 1NG0316 1NG0416 1NG0516 1NG0616 1NG0716 1NG0816 1NG0916 1NG0117 1NG0217 1NG0317 1NG0417 1N00517 1NG0617 1NG0717 1NG0817 1NG0917 1NG0118 1NG0218 1NG0318 1NG0418 1NG0518 1NG0618 1NG0718 1NG0818 1NG0918 1NG0119 1NG0219 1NG0319 1NG0419 1NG0519 1NG0619 1NG0719 1NG0819 1NG0919 11 LENGTH j1 NOMINAL SIZE 21/2" CLOSE 1NG1001 1NG1101 1NG1201 1NG1401 1NG1011 1NG1111 NA NA 31/2" 1NG1011-5 1NG1111-5 NA NA 1NGI012 1NG1112 1NG1212 NA 4 1/2" 1NG1012-5 1NG1112-5 1NG1212-5 NA 5fl 1NG1013 1NG1113 1NG1213 NA 5 1/2" ING1013-5 1NGI113-5 1NG1213-5 NA 1NG1014 ING1114 1NG1214 1NG1414 NA 1NGII14-5 NA NA 1NG1015 1NG1115 1NG1215 1NG1415 ING1016 ING1I16 1NG1216 . 1NG1416 1NG1017 1NG1117 1NG1217 1NG1417 1NG1018 1NG1118 1NG1218 1NG1418 1NG1019 1NG1119 1NG1219 1NG1419 www.sigmaco.com L O Manufactured from carbon steel (which conforms to ASTM A 865 standard) O Threads conform to ASME B 1.20.1 standards for pipe threads. O Sizes 2" and below are straight tapped and 2 1/2" and above are tapper tapped. Description ISize L Item Code D 1/2" 1 MCC0404 1.063" 1.563" 3/4" IMCC0505 1.313" 1.625" 1MCC0606 1.576" 2.00" 1-1/4" 1MCC0707 1.900" 2.063" 1-1/2" 1MCC0808 2.200" 2.063" 1MCC0909 2.750" 2.125" 2-1/2" 1 MCCI 010 3.250" 3.125" 1MCC1111 4.00" 3.250" IMCC12I2 5.00" 3.500" L www.sigmac victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' No. 002 Nominal Outside Size Diameter Elbows Straight Tee No. 001 No. 003 inches inches mm mm 900 Elbow 450 Elbow Branch Run 11/4 1.660 - - - - 32 42.4 - - - - 1½ 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the 1400 Victaulic Field Installation Hardbcsk for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic° is a registered trademark of Victaulic Company. 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 \JtaUIiC Approx. Wt./100 Part No. lbs. (kg) 25 4.8 (2.2) Pipe Clamps TOLCOTM Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2' (40mm) pipe. C®US Material: - Pre-Galvanized Steel LISTED Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Part number and band hanger, size from 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 99 B-Line series Pipe Hangers & Supports LISTED Set Screw and Locknut Included (i9.O ij Set Screw and Lo:knutuded 22.2) Beam Clamps TOLCO Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening TOLCOTM Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2'..13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - /8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, I8'-16 rod will support 1/2" (15mm) thru 4" (1 00mm) pipe 1/2'_13 rod will support 1/2" (15mm) thru 8" (200mm) pipe Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65_112 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-I8 /811-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Mac Rec. Load * Approx. Wt./100 No. in. (mm) lbs. (kN) lbs. (kg) 65_1/2 11/4" (31.7) 1130 (5.02) 55 (24.9) 65-/8 11/4" (31.7) 1130 (5.02) 55 (24.9) * Maximum loads for clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. Component of State of California OSHPD Approved Seismic Restraints System Fig. 65XT-3/8 - Beam Clamp 11/8' C&S —(28.6) Feature: Extruded holes allow for more thread LISTED engagement of threaded rod and set screw. 139.71 Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Design Load: 730 Lbs )3.25kN) Finish: Plain or Electro-Galvanized Order By: Part number and finish Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering Approved (FM) for up to 4" (100mm) pipe. Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 33 B-Line series Pipe Hangers & Supports Beam Clamps TOLCOM Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: /8 -16 & 1/2'13 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized Component of State of C@ Vt.us California OSHPD Approved LISTED Seismic Restraints System A-A Order By: Part number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) * Patent #5,947,424 Slot Width For Use With Length Part No. in. (mm) B3033-3/8, B3034-3/8, B3031-3/8, 69R-3/8-L /16" 111.1) Specify 65-/8, 65XT-3/, 66-/8 69R-1/2-L /16" (14.3) B3033-1/2, 133034-1/2, 651/2, 66-1I2 Specify All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 38 Eaton FIG. 98 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions od Max. Rec. Load Lbs. For Service Temp 3/8 730 1/2 1350 5/8 Component of State of California OSHPD Approved Seismic Restraints System ,.-- I;Ag . 98 - Rod Stiffener FidS98B - Rod Stiffener w/Break-off Bolt Head Size Rang Secures 3/8' thru 7/8" hanger rod Material - Ca7ban Steel Function - Secure hannel to hanger rod for vertical seismic bracing. Approvals - Include our Seismic Restraints Catalog approved Finish - Electro Galvanized Note - Available in HDG finish or Stainless materials Order By - Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 - All Thread Rod Full Lnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.toko.com Size Range: One size fits bracing pipe 1 "(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. 981 K ®TaLccr C®US <e> LISTED Set Screw Included Mounting Hardware Is Not Included To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set screw until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note: Fig. 980 Swivel Attachment and Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 413 or Fig. 4L pipe clamps make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. US Patent Numbers Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 < All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 182 B-Line by 17T4 Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - I811-16 to I411 -10 rods Component of State of California OSHPD Approved Fig. 980H - Universal Swivel Sway Brace Attachment - I811 -9 to 11/4"7 rods Seismic Restraints System * Mounting attachment hole size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. TOLCOTM Seismic Bracing Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2" (50mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" (65mm) through 8" (200mm) pipe. Approved by Factory Mutual Engineering (FM), 2" (50mm) through 8" (200mm) pipe. Installation Instructions: Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. 4-Way Riser Brace plan view) c®US <E> CE Set Scre In Part Pipe Size 2 (50) 5/8 A (136.5) 21/16 I (52.4) I 21/16" (52.4) I Bolt Size 1/2"_13 Max. Rec. uk 2015 Load (8.96) *Max. Design l.k -- Load , (kN) (--) Approx. 247 (112.0) 4L21I2 21/2" (65) 6/16" (163.5) 21/2" (65) 2/4" (69.8) 1/2 .13 2015 (8.96) 3000 (13.34) 253 (114.7) 41-3 (80) (177.8) 2/4" (69.8) 31/16" (77.8) 1/2"13 2015 (8.96) 1550 (6.89) 268 (121.5) 41-4 (100) 81/2" (215.9) 3/8" (85]) 311/16" (937) 1/2"..13 2015 (8.96) 1550 (6.89) 348 (157.8) 41-5 (125) 93/4" (247.6) 3/8" (98.4) 4 /8" (111.1) 1/2"..13 2015 (8.96) 1450 (6.45) 380 (172.3) 4L-6 (150) 111/2" (292.1) 5" 1(127.0)151/8" (130.2) 1/2"13 2015 (8.96) 1450 (6.45) 640 (290.3) 41-8 (200) 131/4" (336.5) 1 5/8' (142.8) 55/8" (142.9) 1/2"..13 1 2015 (8.96) 1450 (6.45) 728 (330.2) 4L-2 Pipe (50) Max. 2015 (8.96) -- *Max. -- -- -- 4L21/2 21/2" (65) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 41-3 (80) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 41.-4 4' (100) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-5 1 (125) 1 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 4L-6 (150) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-8 1 8" 1 (200) 2015 (8.96) 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.13) * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 11/4', 11/2" or 2" Sch. 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 170 B-Line by ff 4'tj Seismic Bracing TOLCO Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 1(25mm) thru 8' (200mm) (PS. * Pipe size used for bracing: 1,(25mm) and 11/4' (32mm) Schedule 40 IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IFS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set screws until heads bottom out. A minimum of 1' (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines, OPA-0300-10. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Component of State of California OSHPD Approved Seismic Restraints System ,@us <~> LISTED AW APPROVED Set Screws Included 41 Pipe Max. Horizontal Design Load (UL) - Lbs. Size For Brace Pipe Size 1"! 11/4 Sch. 7 Sch. 10 Sch. 40 in. (mm) 11" 111/4" 1"/11/4" 1-/11/4- 1 - (25) --I-- 1000/1000 1000/1000 11/4" (32) 1000/1000 1000/1000 1000/1000 11/2" (40) 1000/1000 1500/1500 1500/1500 (50) 1000/1000 2015/2015 2015/2015 21/2" (65) 1600/1600 2015/2765 2015/2765 (80) 1600/1600 2015/2765 2015/2765 (100) 1600/1600 2015/2765 2015/2765 6" (150) 1600/1600 2015/2765 2015/2765 8" (200) 1600/1600 2015/2765 2015/2765 Pipe Size in. (mm) Part Number & Approx. Wt./100 1' (24mm) Brace Pipe I 1I4" (32mm) Brace Pipe Lbs. (kg) j Lbs. (kg) 300-440 Lbs. (kN( Max. Horizontal Design Load (FM) For Sch. 1, Sch. 10, & Sch. 40 Pipe ' 450-590 600-140 Lbs. (kN) Lbs. (kN) 750-900 Lbs. (kN) (25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4" (32) 1001-11/4 X 1 100.0 (45.3) 1001-l'/4 X 11/4 114.0 (51,7) 1230 (5.47) 1740 (7.14) 2140(9.52) 2380 (10.58) 11/2" (40) 1001-11/2 X 100.0 145.31 1001_11/2 X 11/4 115.0 (52.1) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 21/2" 1651 1001-21/2 X 1 138.6 (62.8) 1001_21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130(5.02) 1380 (6.14) 1540(6.85) (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 13.781 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1410 (6.54) 1640 (7.29) 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 217.4 (98.6) 1 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/I 8163 steel pipe. Load rating for Schedule 10 above may be applied to GB/I 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 B-Line series Pipe Hangers & Supports SAMMYS® FOR WOOD -No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a/idea demonstration at www.itwbuildex.com i - #14 Black Nut Driver Part #8113910 i . #14 SW Red Nut Driver Part # 8114910 1/4" 8002957 GST 100 1/4 xl 25 125 670 1/4 8003957 GST 200 1/4 x 2'1760 (Fir) 25 125 Q.. 3/8" 8007957 GST 10 1/4 x 1 300 25 125 3/8 8008957 GST 20 - 114x2 - 1760 (Fir) 850 1475 25 - 125 3/8" 8068925 GST 20-SS 1/4 x 2 1760 (Fir) 850 25 125 F. 3/8 8009925 GST 25-380 318x2-1I2 2113 (Fir) - 1500 25 125 - - <> 3/8" 8010957 GST 30 1/4 x 3 2060 (Fir) - 1500 1475 25 125 - 3/8" - 8069925 GST 30-SS 1/4x3" - 2060 (Fir) - - 25 125 1/2" 8013925 GST2 1/4x2 - 1760 (Fir) 25 125 r - 1/2 8015925 GST3 1/4x3 - 2275 (Fir) - - - - - 25 125 .- t7/( M."a/OFACThREDU S.". V SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not less than 2" nominal width I> (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4' & 5 pipe 4 Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. No pre-drilling required. Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a video demonstration at = wwwifwbulldex.com Q 1/4" 8019957 SWG 200 1/4 x 2" - 1725 (Fir) 25 125 3/8'.8020957 SWG 10 1/4 xl 622 (Fir) - 300 25 - 125 a — 3/8" 8021957 SWG 20 1/4 x-2-' 1725 (Fir) 1050 25 125 — 3/8 8073925 SWG 20 SS 1/4x2"--1725 (Fir) 850 25 - 125 3/8" 8022925 SWG 25-380 SWG 30 - 3/8x2-1/2" 1/4x3 - 2249 (Fir) 1500 - - 25 125 #14SWRed _. 3/8" 8023925 - - 1884 (Fir) - 25 125 Nut Driver Part # 8114910 May require pre-drilling: consult joist manufacturer Eliminates distortion of threaded rod. Accommodates up to 3%" x 12 pitch roof. Allows 170 deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. #14 Black — Nut Driver -1_ t' 3/8" 8139957 SH-GST2O 1/4x2" Part #8113910 1257 (Fir) 1050 . - 1903 Dim Lumber 0 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4 1500 1406 @ 45°off vertical j 850© 45° Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4 1406 © 45°off vertical L Dim. Lumber May require pre-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Part #8273910 1475 25 125 25 125 5125 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5.1 Product Description 3.3.5.1 Product Description Hilti KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide Specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product Features Suitable for cracked and uncracked normal weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size and uses standard ANSI B212.15 - 1994 drill bits. Suitable for reduced edge distances and spacing. 3.3.5.2 Material Specifications Hilti KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8pm. 3.3.5.3 Technical Data The data contained in Tables 1-4 of this section have been evaluated in accordance with AC 193. For more detail, see [CC-ES ESR 3027. Figure 1 - KWIK HUS-EZ I anchor installation details —i d1 tanch I 3.3.5.2 Material Specifications 3.3.5.3 Technical Data 3.3.5.4 Installation Instructions 3.3.5.5 Ordering Information Listinqs/Arrnrovals ICC-ES (International Code Council) ESR-3027 (Cracked & Uncracked Concrete) FM Approved <9> APPROVED Independent Code Evaluation IBC®/ IRC®2009(AC 193/ACI 355.2) IBC®/ IRC® 2006 (AC 193/ ACI 355.2) IBC® / IRC® 2003 (AC 193/ ACI 355.2) 2 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS—EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 1 — KWIK HUS-EZ I (KH-EZ I) Design Guidelines For KWIK HUS-EZ Ii Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head d4 in. 1/4 or 3/8 Wrench Socket Size w in. 3/8 or 1/2 Nominal Diameter da in. 1/4 Drill Bit Diameter dbt in. 1/4 Maximum Installation Torque T.nstpu ft-lbf 18 Maximum Impact Wrench Torque Rating3 Tjmct 114 137 Minimum Nominal Embedment Depth hnom in. 1 5/8 21/2 Minimum Hole Depth hhole in. 2 27/8 Critical Edge Distance2 ca,5 in. 2.00 2.78 Minimum Spacing at Critical Edge Distance Smincac5 in. 1.50 Minimum Edge Distance Cmin5 in. 1.50 Minimum Spacing at Minimum Edge Distance Smin5 in. 3.0 Minimum Concrete Thickness h,ajn in. 3.25 4.125 Anchor Category 3 1 Steel Strength in Tension (ACI 318 D.5.2) Tension Resistance of Steel N lb. 6,070 Reduction Factor for Steel Strength 4)sa - 0.65 Concrete Breakout Strength in Tension (ACI 318 D.5.2) Effective Embedment Depth h.f in. 1.18 1.92 Effectiveness Factor - Uncracked Concrete K - 24 Effectiveness Factor - Cracked Concrete Kcr - 17 Modification Factor for cracked and uncracked concrete c,N - 1 Reduction Factor for Concrete Breakout Strength 0. - 0.45 0.65 Pullout Strength in Tension (ACI 318 D.5.3) Characteristic pullout strength, uncracked concrete (2500 psi) N90 , lb 13056 2358 Characteristic pullout strength, cracked concrete Nper lb 6676 1166 Reduction Factor for pullout strength Op - 0.45 0.65 Characteristic Pullout Strength, Seismic (2500 psi) Np.eg lb 5346 1166 Reduction Factor for pullout strength - 0.45 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies2 Pullout Resistance, (uncracked concrete) - Lower Flute Npdkuflcr lb 12108 1875 Pullout Resistance, (uncracked concrete) - Upper Flute NPdkaflC, lb 14908 1960 Pullout Resistance, (cracked concrete and seismic loads) - Lower Flute Npdk cr lb 6208 930 Pullout Resistance, (cracked concrete and seismic loads) - Upper Flute NpdkCr lb 7608 9759 1 The data presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. See Figure 2. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 T1,st, applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, c,,ln and minimum spacing distance, s, or may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (fc/2,500)13 7 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (fc/2,500)15 8 The characteristic pullout resistance for concrete compressive strengths greater than 3,000 psi may be increased by multiplying the value in the table by (fc/3,000)03 9 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (f'c/2,500)05 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1.800.879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 3 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 2 - Calculated ACI 318-08 Appendix D Strength Design Capacity for Single anchor in Tension' 4,5,6,7 Normal Weight Concrete LWCOMD 2500 psi' 4000 psi 3000 psi' Anchor Internally Nominal Uncracked Cracked Size Threaded Embedment (in.) Head (in.) Depth (in.) Uncracked Cracked Seismic Uncracked Cracked Concrete Concrete Upper Lower Upper Concrete Concrete Concrete Concrete Seismic Lower Flute Flute Flute Flute 1/4 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4x1-5/8 3/8 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1/4x2-1/2 3/8 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1 Values for other strengths can be calculated per (f'c/2500)02 for 1-5/8 embedment and (f'c/2500)05 for 2-1/2" embedment 2 Values for other strength can be calculated per (f'c/3000)02 for 1-5/8' embedment and (f'c/3000)°5 for 2-1/2" embedment 3 Based on single anchor with edge and spacing values greater than those given as critical values in Table 1 4 Based on lower value of concrete breakout or pullout strength 5 These loads are factored resistance loads in accordance with Chapter 9 of ACI 318-08 (ON). 6 Interpolation of values for other embedments is not permitted 7 Minimum concrete thickness and edge distance must comply with Table 1. Table 3- KWIK HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Illustrative Purposes"2'3"5'6'7'8'9'10'1' Internal Thread Diameter Nominal Anchor Diameter Embedment Depth, hnam Effective Embedment Depth, het Allowable Tension Load Head (in.) (in.) (in.) (mm) lb (M)of (in.) (mm) 1-5/8(41) 1.18 (30) 470 (2.1) 1/40r3/8 1/4 2-1/2(64) 1.92 (49) 1340 (6.0) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. Single anchor with static tension load only. Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.21D + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 = 4,000 psi (27.6 MPa) (normal weight concrete). 7 cat = c?c, see Table 1. 8 h ;!h,,,, see Table l. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) - 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Figure 2- Installation of KWIK HUS-EZ I (KH-EZ I) in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Mm 3/4 Structural Sand - Lightweight concrete or normal F--weight concrete over steel deck (minimum 3,000 psi) \ cP Upper L Flute _4-1 Anchor fl\AJX Lower (TY0 Flute Mm. 1-1/4 Mm. 12 (Typ.) (Ridge) Mm. No. 20 gauge steel deck Mm. 4-1/2" 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 4 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS—EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 4 - KWIK HUS EZ I (KH-EZ I) Allowable Stress Design Tension Values for Installations in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Internal Thread Diameter of Head (in.) Nominal Anchor Diameter (in.) Embedment Depth (in.) (mm) Effective Embedment Depth (in.) (mm) Allowable Tension Load lb (kN) Upper Flute Lower Flute 1/40r3/8 1/4 1-5/8(41) 1.18 (30) 466 (2.1) 378(l.7) 2-1/2(64) 1.92 (49) 885 (3.9) 846 (3.7) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.2D + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 f'0 = 3,000 psi (27.6 MPa) (light weight concrete). 7 c 1 = c~ c, see Table 1. 8 h h, see Table 1. 9 Values are for Condition 8 where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) - 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Table 5 - Kwik HUS-EZ I (KH-EZ) Tested Load Values for FM Approval for Automatic Sprinkler Systems Hanger Rod Size (in.) Screw Length FM Test Load FM Maximum Pipe Diameter (in.) Tension lb (kN)) (in.) 1 5/8 3/8 1475 (6.6) 4 2_1/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. Table 6 - Kwik HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Installations into Hollow Core Concrete Panels',' Hanger Rod Size (in.) Mm. Effective Embedment h f (in.) Allowable Load Ultimate Load Tension lb (kN) Shear lb (kN)4.5 Tension lb (kN) Shear lb (kN)45 1/4 13/8 455 (2.0) 485 (2.2) 1810 (8.1) 1,930 (8.6) 3/8 755 (3.4) 3,025 (13.5) 1 The Admissible Anchor Location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm Admissible Anchor Location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a 4:1 factor of safety. 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of ASTM A193, Grade B7 (mm. tensile strength 125 ksi) screws used to fasten the shear fixturing. Shear values should consider the screw or threaded rod strength. Figure 3 - Installation of KWIK HUS-EZ I (KH-EZ I) in Hollow Core Concrete 3.3.5.4 Installation Instructions Use the installation instructions that are including with the Kwik HUS-EZ I packaging box. To obtain a digital copy of the Installation Instructions, visit www.us.hilti.com, www.hilti.ca or contact Hilti Technical Support. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 5 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor The data below is developed from testing performed in accordance with AC! 355.2. It is intended for applications designed according to CSA A23.3-04 Update No. 3 (August 2009) Design Of Concrete Structures Annex D and is generally suitable for the conditions described in the introduction of Annex D. Table 7- KWIK HUS-EZ I (KH-EZ I) Design Guidelines For KWIK HUS-EZ P Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head in. 1/4 or 3/8 Wrench Socket Size in. 3/8 or 1/2 Nominal Diameter da in. 1/4 Drill Bit Diameter db.t in. 1/4 Maximum Installation Torque' ft-lbf (Nm) 18 (24) Maximum Impact Wrench Torque Rating3 T,ctm ft-lbf(Nm) 114 (154) 137(186) Minimum Nominal Embedment Depth hnom mm 41 64 Concrete material resistance factor - 0.65 Steel material resistance factor - 0.85 Ultimate Strength of anchor steel f MPa 924 Effective cross-sectional area of anchor mm2 29.0 Minimum Hole Depth h6010 mm 51 1 73 Minimum Spacing at Critical Edge Distance Smincac mm 38 Minimum Edge Distance cmn° mm 38 Minimum Spacing at Minimum Edge Distance s,,,,° mm 76 Minimum Concrete Thickness mm :83=i Anchor Category 3 1 Steel Strength in Tension (GSA A23.3 D.61) Factored Steel Resistance in Tension N, kN 15.9 Reduction Factor for Steel Strength R - 0.70 Concrete Breakout Strength in Tension (CSA A23.3 D.6.2) Effective Embedment Depth hef mm 30 49 Critical Edge Distance2 cac° mm 51 71 Effectiveness Factor - Uncracked Concrete K uncr - 10 Effectiveness Factor - Cracked Concrete Kcr - Modification Factor for cracked and uncracked concrete c,N - 1.4 Reduction Factor for Concrete Breakout Strength I R 1 0.70 1.00 Pullout Strength in Tension - Non Seismic Applications (CSA A23.3 D.6.3) Factored Pullout Resistance, uncracked concrete (17.23 MPa) Nprencr kN 2.66 6.8 Factored Pullout Resistance, cracked concrete (17.23 MPa) Nprcr kN 1.36 3•47 Concrete Resistance Factor for pullout strength oc,pull - 0.65 Factored Pullout Strength, Seismic (17.23 MPa) Npreg kN 1.16 [ 3•47 Concrete Resistance Factor for pullout strength c,seis - I 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies' Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Lower Flute N pr, dkuflc, kN 2.48 549 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Upper Flute Nprdeckuncr kN 3.08 579 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Lower Flute Np,deckcr kN 1.38 2.7 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Upper Flute Nprdeckcr kN 1.58 2.89 1 The data presented in this table is to be used in conjunction with the design criteria of CSA A23.3-04. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, and minimum spacing distance, 5,,no,smjfl may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 17.23 MPa may be increased by multiplying the value in the table by (f'c/17.23)03 7 The characteristic pullout for concrete compressive strengths greater than 17.23MPa may be increased by multiplying the value in the table by (f'c/l 7.23)° 8 The characteristic pullout resistance for concrete compressive strengths greater than 20.68 MPa may be increased by multiplying the value in the table by (fc/20.68)03 9 The characteristic pullout for concrete compressive strengths greater than 20.68 MPa may be increased by multiplying the value in the table by (fc/20.68)0'5 6 Hilti, Inc. (US) 1.800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 3.3.5.6 Ordering Information Order Information Internal Thread Internal Thread Hole Minimum Qty Description Diameter Length Diameter Embedment (pcs) / Box KH-EZ 1/4'xl-5/8" I 1/4" 1/4 3/8" 1/4 1-5/8 100 KH-EZ 1/4"x2-1/2" I 1/4" 1/4 3/8" 1/4 2-1/2 100 KH-EZ 1/4'xl-5/8" I 3/8" 3/8" 7/16' 1/4 1-5/8 100 KH-EZ 1/4"x2.1/2" I 3/8" 3/8" 7/16' 1/4" 2-1/2" 100 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiltLca I Anchor Fastening Technical Guide 2011 7 Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation, corrosion, and spacing and edge distance guidelines, please refer to the Technical Guide, or contact Hilti. Hilti, Inc. 5400 South 122" East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com ®POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) 400 to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX- 1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in T.JL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. UILC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .1 2A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6 (150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .1 7A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .1 7A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* 1 .OSA 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 1 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. !TiTI1:1IIEe In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK- 1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-! PAGE 1 OF 2 Ot/13 ® POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 A.C. BELLS 1011 WHITE (IN) WHITE (OUT) i (2 FROM CONTROL PANEL OR __ __ BLACK (IN)ACK (OUT) PRECEDING BELL CAUTION: 2 11/16" WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LS AS SHOWN. (68) NOTES: DWO# 776.1 I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELYAPTER LAST BELL. 2. END-OF-LM RESISTOR IS NOT REQUIRED ON AC BELLS. DWG6 776.3 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2 conduit entrance ,,+J fl 85 5 3/4" ((46) (86)- 4 1/4" (108) OWG6 776.2 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). WARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 2 OF 2 01/13 o)) POTTFR LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending, Potter Electric, Rd., 1990 General Information The Model VSG is a flexible vane type of waterfiow switch for use in wet pipe water mist systems where a low flow for alarm is required. It is designed for installation in sections of 2 to 4 inch (50mm to 100mm) stainless steel or brass pipe with wall thickness in accordance with the above specifications (see "Nominal OD and Wall Thickness"). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains an output relay and an adjustable electronic retard. The relay is actuated when a flow of 3 gallons per minute (11,4 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. Afield installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC, and CSFM Listed Service Pressure: Up to 450 PSI (31 BAR) Flow Required for Alarm: 3.0 GPM (11,4 LPM) Maximum Surge: 18 FPS (5,5 m/s) Power Requirements: STANDBY: lOma at 120V AC or 1.5ma at 24V AC/DC ALARM: 40ma at 120V AC or 35ma at 24V AC/DC Contact Ratings: DPDT (Form C) 2 Amps at 0-30VDC or 0-125VAC resistive Conduit Entrances: 2 knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/120°F, 4,5°C/490C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Nominal OD and Wall Thickness: (60,3mm OD), 3,9mm to 4,5mm wall 2 1/2" (73,0mm OD), 4,8mm to 5,2mm wall 2 1/2" (76,1mm OD), 4,3mm to 4,7mm wall (88,9mm OD), 5,0mm to 5,6mm wall (114,3mm OD), 5,4mm to 6,4mm wall Service use: Water mist systems where low flow for alarm is required. Optional: Cover Tamper Switch Kit, Stock No. 0090018 Installation See Fig. 1 These devices may be mounted on a horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" +1/8" -1/16' (32mm + 2mm). The 3" (80mm) and 4" (100mm) devices require a hole with a diameter of 2" ± 1/8" (50mm ± 2mm). Clean the inside of the pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 20 ft-lbs. (27 n-m) of torque. See Fig. 1. The vane must not rub the inside of the pipe or bind in any way. Potter Electric Signal Company. 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MFG. #5400999 - REV M PAGE 1 OF 2 5/08 W LEAVE COVU1 OFT FOR 60 P0000 OF n017 Fig. 1 PIPE SIZE HOLE SOS 2 to 2-1/2 1-1/4 + 1/8' /8 - 1/16 (60 to 60mm) (33mm :t2mm) 3to4 2±1/8 (60 to 100mm) (50mm ± 2mm) 10 INSTAll., DRILL HOLE AS INDICA1OO. RETAI60 TIME SaE1OR 5*0tH 110H1624 Nuts ALTERNATELY TO AN EVENTUAL n-m) OF TORQUE MOUNT ON PPE SO ARROW ON SADDLE POWIS IN DIRECTION OF WA1ERFIDW ROLL PADDLE IN - Oppr DIRECtiON OF *A1ERFLO* Apro' h VSG p OT T E R LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD Retard Adjustment The retard time is selected by turning the appropriate switches to the off position. Example: For 45 seconds turn switches 1, 2 and 3 to the off position. Approximate time is as follows: Switch Off Time in Sec. 1thru80n 0 1 15 l&2 30 l,2,&3 45 1,2,3,&4 60 1,2,3,4,&5 75 1,2,3,4,5,&6 90 7 not used 8 not used 5*0. 1162-30 Fig. 2 Typical Electrical Connections RELAY ACTION NO, CON N.C. ____ 12 4/6 WIRE CONTROL PANEL CIRCUIT DETECTOR CIRCUIT END OF LINE FROM PANEL II II ....LjRESISTOR RETURN TO CONTROL PANEL 24V DC POWER, II II el 24VDCRELAY CON. N.0.CON.N.C. SHOWN ENERGIZED NOTE: BASE MUST BE CONNECTED TO A GOOD EARTH GROUND. LOW VOLTAGE DC DWG. #985-I èeê è'èe 4, 1200240 COiL P&0.COM.N,C 060 AUX. . CONTACTS I -KO. HIGH VOLTAGE 24V I BELL04 I e e 1200240 CON. N.O.COU. N AUX CONTACTS 00,L LOW VOLTAGE AC Fig. 3 Switch Terminal Connections Clamping Plate Terminal .,,OXIN DWG' 923.3 o'5 I A CAUTION I When supervised circuits are used the following must be observed: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Application Warning! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Testing: The operation of the waterfiow switch and the associated alarms is to be tested upon completion of the installation and periodically thereafter in accordance with the applicable NFPA standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). A minimum flow of 3 GPM (11,4 LPM) is required to activate this device. PRINTED IN USA MFG. #5400999 - REV M PAGE 2 OF 2 5/08 7M, Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve The AGF Model 1011 TESTANDRAIN® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 1011A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011 is available in a full range of sizes (34' to 2') with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UL/FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: 3/8" (2.8K), /16" (4.2K), ½" (5.6K), 17/32" (8.0K), 5/8" (11.2K, ELO), 3,4" (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. _- SS-M101 1A V001 . 06/13 TESTaNORAIN5 is a registered trademark of AGE Manufacturing Inc. 211MUNWA C @ LISTED Wu& Model 1011 A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVED Factory Rated at 175 PSI with other setting available Model 1011 A - Front View SIZE A B C D E F G H 3/4" 79/16" 11/2 23/i6" 3/8" 3%" 113A6" 49/16" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 7A6" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4 715A6" 111A6" 29/16" 41/4" 35/8" 11W16" 59A6" 71/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 11/2" 815/16" 113A6" 31/4" 51/" 37/8" 25/8" 81/4" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815A6" 113A6" 31/4" (83 1/4" 51/i6" (5 1/16" 37/g" 2/8" 8" (2071/m m) 10/8" (227 mm) (45 mm) (127 mm) (99 mm) (67 mm) (274 mm) The Model 1011 A provides the following... From the 2013 Edition of NFPA 13 Chapter 8.16.24.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.1 7.4.2.2 The test connection valve shall be accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterf low alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1 'in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1', at least one of which shall be brass. Chapter 7.1.2 - a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve Model 1011 - Plan View Orifice Sizes 7Ae", ½", "112",%" ELO*, 3/4" ESFR*, and K25** Materials Handle................Steel Stem...................Rod Brass Ball ...................... CR Brass Body...................Bronze Valve Seat...........Impregnated Teflon® Indicator Plate .... Steel Relief Valve ...... ... Bronze Bypass Fittings... Brass Bypass Tubing.... Nylobraid Approvals UL and ULC Listed: (EX4019 & EX4533) FM Approved 4--W@ NYC-BSA No. 720-87-SM MADE IN U.S.A. . .. ..., I AGF Manufacturing Inc. . .. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 : . Fax: 610-240-4906 www.testandrain.com 'Available on 11/4" to 2" size units only • ""Available on 11/2" and 2' size units only Dimensions Job Name: Architect: Engineer: Contractor: FireLock® Butterfly Valve 4tauIiC Style 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12/50 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c®us E USTED G410001 104j/04 NOTES Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.Com 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. 1 X. l -U1 ii e vietiiilirtnm 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 50 I up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa I up to 300psi/2068kPa I up to 300psi/2068kPa 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa =upto 1/2068kPa 100 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa I up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm upt0300ps1/2068kPa upt0300p5i/2068kPa n/a upt0300psi/2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS - MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6"I50 - 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"/200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: O 2-8/50-200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing F1 10 - 12/250 - 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 2 \4taUIiC victaulic.com 4.0 DIMENSIONS Style 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 1 2.375 4.25 2.28 6.41 1 - - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 - - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 761 mm 3.000 3.77 2.28 7.54 - - 4.00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 - - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 643 197.9 114.3 107.2 114.3 45.0 108mm 4.250 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 It 108.0 117.6 73.2 1 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 - 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 1397mm 5.500 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 - 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 159mm 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 1651mm 6.500 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 203 37.3 254.0 I 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 - 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 230 2.80 14.25 8.10 9.00 - 323.9 323.9 165.1 186.9 422.7 1 58.4 71.1 362.0 205.7 228.6 NOTE Optional 1h'/15mm tap available. Contact Victaulic for details. 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com \j4taUIiC victaulic.com 5.0 PERFORMANCE Style 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/rn inches inches of pipe 2 2.375 6 50 60.3 1.8 2½ 2.875 6 65 73.0 1.8 3 76.1 mm .000 6 76.1 1.8 3 I 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 12 125 1 141.3 3.7 133 mm 133 mm 12 3.7 5 139.7 mm .500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm I 6.500 14 165.1 4.2 8 1 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev G Updated 08/2016 © 2016 victaulic Company. All rights reserved. victaulic.com 4 \41tauIic victaulic.com 5.1 PERFORMANCE Style 705 Cv values for flow of water at +60°F/-i-16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K values LW = Q2 Where: AP = Q2 Q= Flow (GPM) - LW = Pressure Drop (psi) Q = C x /AP C= Flow Coefficient Q = Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches mm mm 2 2.375 170 50 60.3 2½ 2.875 260 65 73.0 76.1 mm 1 3.000 260 76.1 3 3.500 440 80 88.9 4 4.500 820 100 114.3 108mm 108mm 820 5 5.563 1200 125 141.3 133mm 133mm 1200 139.7 mm 5.500 1200 139.7 6 6.625 1800 150 168.3 159 mm 159 mm I 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 1 12.750 9000 300 j 323.9 Where: Q = Flow (m3/hr) LW = Pressure Drop (Bar) KV = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches mm mm 2 2.375 147 50 60.3 2½ 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133mm 133mm 1040 139.7 mm 5.500 1040 139.7 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 7790 300 323.9 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5 \4taUlicr victaulic.com 6.0 NOTIFICATIONS WARNING ME Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC Switches supervise the valve in the "OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe EL LISTED JUNCTION BOX CON EU Fr W NET CONDUIT CONNECTORS FORE NUTS FIRE ALARM END IN TO END-OF-ILINE RESISTOR CONTROL PANEL I OR OR INDICATOR SUPERVISORY CIRCU I SWITCH RATING 10A AT 20 AND 25OVAC. 0.5A AT 25 SOC. 0.25 AT 250 VDC U 52 BELL OR VOLTAGE SOURCE HORN Switch 1 2 leads per terminal Switch 2 1 lead per terminal NOTES The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe —S2) and the normally closed terminal (blue - Si and blue-with-orange Stripe —S2). In this example, the indicator light and alarm will Stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com sj4 -C ta uiic victaulic.com 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty -100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patentor other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 4tEUUIiC MODEL MVC-15 METRAVENT AUTOMATIC AIR VENT APPROVED 175 PSI 5 PART PART NAME MATERIAL PART PART NAME MATERIAL 1 BODY CAST IRON A126 7 COVER BOLT CARBON STEEL 2 COVER CAST IRON Al 26 8 FLOAT ARM STAINLESS STEEL 3 LEVER FRAME STAINLESS STEEL 9 ORIFICE BUTTON FLUOROELASTOMER 4 SEAT STAINLESS STEEL 10 PIVOT PIN/RETAINER STAINLESS STEEL 5 FLOAT STAINLESS STEEL 11 PIPE PLUG (0.5") STAINLESS STEEL 6 GASKET NON ASBESTOS 12 LOCATOR STAINLESS STEEL QTY SIZE PART NUMBER MAX TEMP INLET SIZE OUTLET SIZE ORIFICE SIZE WI (LBS) 1/2 (15mm) MVC150050 250°F 1/2" NPT 1/2" NPT 1/16' 5-1/2 3/4" (20mm) MVC 150075 250°F 3/4" NPT 1/2" NPT 1/16" 5-1/2 1" (25mm) MVC150100 250°F 1" NPT 1/2" NPT 1/16" 5-1/2 NSF 372 - LEAD FREE The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Material complies with state codes and standards, where applicable, requiring reduced lead content. CUSTOMER: PROJECT: ENGINEER: I REV. 1 PART NUMBER UPDATED DATE 2/28/2017 2323 W. HUBBARD IT. CHICAGO, IL 60612 I\'l c4I TEL: 312 et r eç -738-3800 ® FAX: 312-738-0415 cor pipes in motion WWW.METRAFLEX.COM MODEL MVC-15 METRAVENT AUTOMATIC AIR VENT SCALE: IDRAWING NUMBER: MODEL MVC-30 METRAVENT AUTOMATIC AIR VENT MAX WORKING PRESSURE 300 PSI @ 150°F 260 PSI @ 250°F PART PART NAME MATERIAL PART PART NAME MATERIAL 1 BODY CAST IRON A126 7 COVER BOLT CARBON STEEL 2 COVER CAST IRON Al 26 8 FLOAT ARM STAINLESS STEEL 3 LEVER FRAME STAINLESS STEEL 9 ORIFICE BUTTON FLUOROELASTOMER 4 SEAT STAINLESS STEEL 10 PIVOT PIN/RETAINER STAINLESS STEEL 5 FLOAT STAINLESS STEEL 11 PIPE PLUG (0.5) STAINLESS STEEL 6 GASKET NON ASBESTOS 12 LOCATOR STAINLESS STEEL QTY SIZE PART NUMBER MAX TEMP INLET SIZE OUTLET SIZE ORIFICE SIZE WI (LBS) 1/2" (15mm) MVC300050 250°F 1/2' NPT 1/2 NPT 1 /1 6" 8 3/4" (20mm) MVC300075 250°F 3/4' NPT 1/2 NPT 1/16" 8 1' (25mm) MVC300100 250°F 1' NPT 1/2 NPT 1/16" 8 NSF 372 - LEAD FREE The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Material complies with state codes and standards, where applicable, requiring reduced lead content. CUSTOMER: PROJECT: ENGINEER: REV. 1 I PART NUMBER UPDATED DATE 2/28/2017 AW 2323 W. HUBBARD ST. CHICAGO, IL 60612 ex ,Metrafl TEL: 312-738-3800 ® FAX: 312-738-0415 ...Jor pipes in motion WWW.METRAFLEX.COM, MODEL MVC-30 METRAVENT AUTOMATIC AIR VENT APPROVED: ZB I DATE: 9/4/2015 SCALE: IDRAWING NUMBER: 300 psi UL/ULC Listed* Description The 1/4" IPS three-way female threaded valve is used to facili- tate the installation of sprinkler system pressure gauges. The valve provides for one inlet and two outlets. This design allows for replacement of the system gauge without shutting down the water supply to the sprinkler system. This design also allows Authoritys' Having Jurisdication to test system pressure with an additional gauge through the second outlet. (The second outlet is normally plugged during installation with a 1/4" IPS pipe plug.) Installation Specifications Materials: Seat - Brass Body- Brass Handwheel - Iron Sizes: 1/4" IPS Working Pressure: 400 WOG Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has Thread Sealing Tape or a suit- able pipe thread sealant such as PipeFir Thread Sealant Paste with PTFE when in- stalling the valve. DO NOT OVERTIGHTEN THREADS. been cast into the valve body. OVERTIGHTENING MAY The most common installation CAUSE VALVE FAILURE. allows for a 1/4" IPS nipple *UL/ULC Listed 2R97 between the valve and the water supply being measured. This assures there will be ad- equate spacing for the sprin- kler system gauge from the riser. Use either PTFE Pipe Fire Protection Products, Inc. ©2003-2007 Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 1 For questions: 1 800 344-1822• 1 800 344-3775 fax• www.fppi.com © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc. FBC"', BlazeMaster®, FlowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipef it® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. L.i 1JS1 *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL +1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55g1. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com DIEGO SEAL, 7635 RONSON ROAD • SAN DIEGO, CA 92111 • TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: salessandiegoseaI.com • VISIT US AT: www.sandiegoseal.com PTFE Thread Sealant Tapes Made in the USA ur thread sealant tape breaks clean without shredding r warping, identifying it as a product that can be trusted perform reliably when the job is completed and the ressure is on. Standard Grade Our standard grade PTFE Thread Sealant Tape is for those / applications that do not require the sealing properties of a premium grade thread sealant. This is intended to be used for general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, clean, economical sealing of male pipe threads of all sizes and reduces the risk of system contamination common with liquid and paste sealants. is effective and efficient so you can use less tape. Tears cleanly ... seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. PTFE Thread Sealant Tapes ;k of system contamination common with liquid and paste sealants. Our full density premium and gas line tapes meet ii Spec A-A 58092 for liquid & gaseous oxygen applications. The self-lubricating quality of this unsintered tape akes joints easy to assemble and disassemble. Totally maintenance free, full density PTFE thread sealant tape is tually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-0°C) to +500°F (+260°C), and pressures from a hard vacuum to 10,000 PSI. properties of PTFE thread sealant tape are as follows: Typical Properties I Grade i Standard Grade Premium Grade Premium Grade Premium Grade - Yellow St-andard Den! IFull Density IFull Density I I I I Maximum sealing . u kompiies with certain i rower. puilding codes requiring Description IThe economical choice More sealing power I oo efficient, ou t can use less IjeIlow, thicker, more I' I I 1ae ense tape for gas r___ecelines Color Nhite orcolors yhiteorcolors tNhiteor colors frellow_- ____________________ Density tanlard 0.5 to0.7 tandard1.0to1.2 tandard1,5tandard1.6 Thickness D.003"to0.0035" 10003" to 0.0035" 10003" to 0.0035" I Standard Widths & Lengths /"x 260" A"x520" /4"x 1296" /2"x 260" /2"x 520" /2"x 1296" /"x 260" h"x 520" "x 1296" 1"x 260" 1"x 520" 1"x 1296" uantity 144 rolls per box 44 rolls per ~ox 144 rolls per box Vhite All industrial applications. Made from virgin PTFE 'ink For use in plumbing and pipe fittings (water and steam lines) ray For stainless steel pipe/fittings 3reen For oxygenapplications t'ellow For gas line use SAN DIEGO SEAL, INC 7635 RONSON ROAD • SAN DIEGO, CALIFORNIA 92111 TEL: 858-278-3270 9 FAX: 858-278-2950 E-MAIL: salessandiegoseaI.com 9 VISIT US AT: www.sandiegoseal.com