Loading...
HomeMy WebLinkAbout2386 FARADAY AVE; 200; FPC2019-0143; Permit(r'city of Carlsbad - Print Date: 04/13/2022 Permit No: FPC2019-0143 Job Address: 2386 FARADAY AVE, # 200, CARLSBAD, CA 92008-7259 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120621700 Track #: Applied: 06/25/2019 Valuation: $415,241.28 Lot #: Issued: 07/15/2019 Occupancy Group: Project #: Finaled Close Out: 02/23/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: HAVAS EDGE -EXPAND FIRE ALARM TO SERVE 2ND FLR TENANT (JOINS/EXPANDS INTO BUILDING 2382 FARADAY ON 2ND FLC Applicant: LOW VOLTAGE INTEGRATED SYSTEMS KYLE ARGUIJO 1090 JOSHUA WAY, # STE A VISTA, CA 92081-7800 (760) 598-4110 FPContractor: LOW VOLTAGE FIRE INC 1090 JOSHUA WAY, # UNITA VISTA, CA 92081-7800 (760) 598-4110 FEE AMOUNT FIRE Hourly Services Each Additional Hour $136.00 FIRE Hourly Services First Hour $159.00 FIRE Reinspection (per inspection) $193.00 FIRE TI Fire Alarm System $620.00 Total Fees: $1,108.00 Total Payments To Date: $1,108.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 1 4 FIRE ALARM SYSTEM SUBMITTAL Lw%itcwge t g ci t d s y s tfa m s FIRE ALARM SOUNDS DATA MEDIA • SECURITY* CCTV I ACCESS CONTROL SUBMITTAL HAVAS EDGE EXPANSION 2ND FLR TI 2382 & 2386 FARADAY AVE CARLSBAD CA 92008 FPC20I9-0143 2386 FARADAY AVE #200 HAVAS EDGE - EXPAND FIRE ALARM TO SERVE 2ND FLR TENANT (JOINS/EXPANDS INTO BUILDING 2382 FARADAY ON 2ND FLOOR) 2120621700 6/25/2019 FPC20I9-0143 LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1090 JOSHUA WAY STE A VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: C10, C16 # 791832 a 0 S Lo wVolsage i ntegratecil sy s te ms PHONE: (760) 598-4110 FAX: (760)598-4107 MATERIAL LIST PART DESCRIPTION MANUFACTURER FCPS-24S6 FIRE ALARM POWER SUPPLY NOTIFIER PC2WL HORN/STROBE @CEILING SYSTEM SENSOR SCWL STROBE ONLY @CEILING SYSTEM SENSOR NP-100 SMOKE DETECTOR NOTIFIER NMM-100 MONITOR MODULE NOTIFIER NC-100 CONTROL RELAY NOTIFIER S Low Voltage Integrated Systems, Inc. 1090 Joshua Way, Ste A • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. CIO, C16 #791832 email: info @ sdlvis.com dn-6927:a FCPS.24S6(C/E) & FCPS. O 24S8(CIE) 6- & 8-Amp 24-Volt Remote Power SuDolies NOTIFIER® by Honeywell General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-2456/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-2456C & FCPS-2458C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E - '- S S Features UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-24S6) or 8-amp (FCPS-2458) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL864). 4-amp (FCPS-24S6) or 6-amp (FCPS-2458) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). Includes integral battery charger capable o charging up to 18 AH batteries. Cabine capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCFS-24S6/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. FCPS-2456E/-2458E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 fDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current 1br al outputs (stand-alone mode): - FCPS-24S6: 4.0 A maximum. - FCPS-24S8: 6.0 A maximum. Total short-term current fcr all outputs (NAC expander mode): - FCPS-24S6: 6.0 A maximum. - FCPS-2458: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Flow-charge voltage: 27.6 VDC. dn-6927:a • 04/3O09 - Page 1 of 2 S Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-2456) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-2456) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24S6/-2458 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-2458 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-2456 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-2456C & FCPS-2458C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-Iisted. FCPS-24S6R: Same as FCPS-2456 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1 109) System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 2211229WWWWWWN9 Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. S ENEIREIIIIIIIII 8 fli N8 UF All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-6927:a • 04/30/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM O LISTING SERVICE LISTING No. 17315-0028:0225 I Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: Models and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-03KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17135-1653:05031 Page 1 of 2 CATEGORY: 7135-- AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC21RL,IPC2WLI *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, S Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walilrim Rings: *TR2 and *TR2W Ceilinglrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. S Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division The System Sensor L-Series offers tne most versatile and easy-to-use line of-horns, strobes, and horn strobes in the industry with lower currert craws and modern aeslhetics. With white and red plastic housings, v-all and ceiling mounthg options, System Sensor L-Series -car meet virtually any application requirement. The entire LSeries product line of ceiling-mount strobes and horn strobes include a 'tar aty of features that increase their application versatility while simplifying installatior. Au devices feature a plug-in design with minimal intrusion into the back box, making installations fast and -oolprocf wnile virtually eliminating costly and time- consuming grounc faults. To further simplify installation, the L-Serieu. utilizes a universal mounting plate so ,nstallers can mount them to a wide array of back boxes. t/ith an onloard shorting spring, Installers can test wiring continuiN before the device is installed. Installers can also eaoily adapt devic3s to a suit a wide range of application requirame nts using field-selectable candela settings, automatic seIectio C' 12-or 24-volt opeation, and a rotary switch for horn tones with two volume selections. O SYSTEM $ SENSOR 'A Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115,150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNALING LISTED O APPROVED S5502 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync'Circuit ° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17,5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 34" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P. S. PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV0S86800 0 UL Current i UL Max Strobe Current Draw (mA RMS),.-..?V'~;!Mr 8-175 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 1177 I N/A I 226 j 264 8-17.5 Volts DC Input 15cd 30cd 16-33 Volts 115cd 30cd 75cd 95cd 115cd I 150cd 1177cd Temporal High 103 167 171 90 143 165 187 1 217 1254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3. 1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 . 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 Temporal _2 Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temooral Low 77 83 83 C AVOSS6BOO 2.47 1.37 0 a rim I Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Dimensions Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Strobes SCRL Strobe, Red ISCWL Strobe, White I SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red I PC2WL 2-Wire, Horn Strobe, White SYSTEM ©2017 Systerrr Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notce. Visit systenrsensor.com Phone: 800-SENSOR2 • Fax' 630-377-6495 or current product intorrnation, including the latest version of this data sheet. AVDS86601 • 03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17125-1653:05041 Page 1 of 2 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRLI SCWU and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. 10 Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 C RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/wr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires ,June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6995:C • Al -320 0 NP-100(A) Series Addressable Photoelectric Detectors for the FireWarden Series ©NOTIFIER® hi I-inn cvni II 7 I I t I •7 V V II General Addressable The NP-100(A), NP-1100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A) adds thermal sen- sors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-11 OOR(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detector housings. Features SLC loop Two-wire loop connection. Unit uses base for wiring. Addressing • Addressable by device. Rotary, decimal addressing: 01 —99 with FireWarden-100-2 and NSP-25, and 01 —50 with FlreWarden-50. Architecture Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type Identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features Fully coated circuit boards and superior RF/translent pro- tection. 94-VO plastic flammability rating. Low standby current. Options Remote LED output connection, PN RA100Z(A). NP-100(A) in B2IOLP(A) Base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of oft-white fire resistant plas- tic. NP-100(A) series plug-In, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation NP-100(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps' or branches are permitted for Style 4 (Class B) wiring. NP- IOOR(A) mounts in a DNR(A)/DNRW duct detector housing. Operation Each NP-100(A) series detector uses one of 99 possible addresses on the FireWarden-1 00-2 and NSP-25, or one of 50 possible addresses on the FireWarden-50 Signaling Line Cir- cuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the NP-i 00(A) series has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of Its unipolar cham- ber, the NP-100(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DN-6995:C • 12/07/2011 - Page 1 of 2 Detector Sensitivity Test NP-i OORA: Same as NP-100R with ULC Listing for use with a S Each detector can have its sensitivity tested (required per DNRA duct detector housing; B210LPA base included. NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NOTE: "A" suffix indicates ULC Listed modeL den-50 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire,, NOTE: For details about intelligent bases and their mounting, see Warden-50 for record keeping. DN60054. B21OLP(A): Plug-in detector base (Included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15 -32 VDC (peak) Standby current: 300 pA © 24 VDC. LED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501(A): 4.1" (10.4 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (1029). Operating temperature range: for NP-100(A): 0°C to 49°C (32°F to 120°F); for NP-100T(A): 0°C to 38°C (32°F to 100°F). NP-IOOR(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the NP-100(A), NP- 100T(A), and NP-100R(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. UL Listed: S11i5. ULC Listed: S911. CSFM: 7272-0028:0231. MEA: 243-02-E Vol. 2. Maryland State Fire Marshal: permit 2173. FM approved. Product Line Information NOTE: "A" suffix indicates ULC Listed model. NP-100: Adressable photoelectric detector; B21OLP base included. NP-100A: Sames as NP-100 with ULC Listing; B21 OLPA base included. NP-100T: Same as NP-100 but with thermal element; B21OLP base included. NP-IOOTA: Same as NP-100T with ULC Listing; B21OLPA base included. NP-100R: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B21OLP base included. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B50 1; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-In System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC Inductive; 1.0 A 0 30 VDC inductive. 8224B1(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). ACCESSORIES F1I0: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F1i0BP: Bulk pack of Fib; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. X1134: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with NP-i 00(A) only; box of 10. WCK-200B: White detector covers for use with NP-100(A) only; box of 10. NOTIFIER® and FlreWarden® are registered trademarks of Honeywell International Inc. 02011. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. S MIIIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6995:C • 12/0712011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17272-0028:0231 I Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett©honeywell.com DESIGN: Models INP100jNP100R* and NP-lOOT photoelectric type smoke detectors. Model NP-lOOT has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0- 4000 FPM. *Models NP-100 and NP-IOOR are also approved for installations inside Notifier duct detector housing ND-200 (OSFM Listing No. 3242-0028:236) and System Sensor duct detector housing DNRW (OSFM Listing No. 3242-1653:210). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:0194 *Rev. 01-27-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Monitor Modules DN-6999:C I NMM-100(A), NMM.IOOP(A), I NOTI Fl ER® NZM-1 00(A), and N DM1 00(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General I Four different monitor modules are available for Notifiers Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-1 00(A)). NMM-100(A) is standard-sized module (typically mounts to a 4° [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-1 OOP(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-1 00(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. NMM.100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on FlreWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-In rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) (Type H) NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module Is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 930% noncondenslng. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125" (5.398 cm) deep box. I DN-6999:C • 10/06/2010 - Page 1 of 4 NMM-1 OOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. 1415 0 1 ADDRESS 1 I 13(,\,2 2 LOOP 11 4 n 8 76 8 76 TENS ONES The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. NMM-1 OOP(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of Its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Page 2 of 4— DN-6999:C • 10/06/2010 Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0,65" (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. NZM.100(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address:, 01 - 99 on FireWarden- 100-2, 01 —50 on FlreWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the Individual address of each module Is selected using built-In rotary switches. This module allows Intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports Its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum, Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondenslng. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125" (5.398 cm) deep box. I NDM.100(A) Dual Monitor Module S The NDM-1 00(A) Dual Monitor Module Is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY Style 0 (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 IJA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 491C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 Cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-1 00(A) automatically assigns Itself to two address- able points, starting with the original address. For example, if the NDM-1 00(A) Is set to address "26", then it will automati- cally assign itself to addresses "26" and "27", NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4(10.16cm) square, 2.125° (5.398 Cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is Intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC:S635 FM Approved S . CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100) MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: "A" suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN52304. DN-6999:C • 10/06/2010 - Page of 4 Notifier® and FireWarden® are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 We This document is not intended to be used for installation purposes. try to keep our product information up-to-date and accurate. 4CROMM 3M M1 &MMUFAC1R1NC QUALITY SYSTEMS We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4014— DN-6999:C • 10/06/2010 S dn-7000:a2 • Al -360 NC-100(A) NOT IF I ER® S Control Module for FireWarden Series Panels by Honeywell General The NC-100(A) Addressable Control Module provides NOTI- FIER's FireWarden Series intelligent control panels a super- vised Class B (Style Y) of Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the NC-100(A) to be activated, either manually or through panel programming, on a select (zone or area of cov- erage) basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry powered directly by two-wire SLC loop. The NC-1 00(A) module requires power (for horns, strobes, etc.). Integral LED "blinks" when communicating, and turns on steady when activated. High noise immunity (EMF/RFI). The NC-1 00(A) may be used to switch 24-volt NAC power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with FireWarden- 100-2(C), or 01-50 with the FireWarden-50(C). Applications The NC-1 00(A) is used to switch 24 VDC audible/visual power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-1 00(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. Operation Each NC-1 00(A) uses one of the module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The NC-100(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the NC-100(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay-isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. NC-100(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 350 pA (LED flashing). External supply voltage: maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. FM approved ULIULC Listed: file S635. CSFM approved: file 7300-0028:230. MEA approved: file 72-01 -E Vol. 2. dn-7000:a2 • 06/17/10 - Page 1 of 2 Contact Ratings Current Maximum Load Application Rating Voltage Description 3A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (L/R=5ms) 1A 30 VDC Inductive (LIR=2ms) Coded .3A 125 VAC Inductive (PF=0.35) Non-Coded Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded Product Line Information NC-100: Intelligent addressable control module. NC-100(A): Intelligent addressable control module, ULC listed version. SMB500: Optional surface-mount backbox. CB500: Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in the same junction box as NC-1 00(A). NOTE: For installation instructions, see document /56-2592-001 and refer to the SLC Wiring Manual, document 52304. The NC- 100R(A) relay module, previously on this data sheet, is now on DN-60383. fl NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-7000:a2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1 7300-002-8,0230 1 Page 1 of I CATEGORY: 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotiflerOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneyweIl.com DESIGN: Models NMM-100P,INMM-1 001 and NZM-100 monitor modules; Models NC-100R and INC-lOOlcontrol modules; and *NZMIO0-5 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 0