Loading...
HomeMy WebLinkAbout2292 FARADAY AVE; ; FPC2017-0078; Permit(àity of Carlsbad Ift Print Date: 04/13/2022 Permit No: FPC2017-0078 Job Address: 2292 FARADAY AVE. CARLSBAD, CA 92008-7238 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120614400 Track #: Applied: 03/27/2017 Valuation: $654,907.31 Lot #: Issued: 04/04/2017 Occupancy Group: Project #: Finaled Close Out: 05/03/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check #: Final Inspection: Project Title: Description: CARLSBAD EXECUTIVE SUITES -FIRE ALARM *revisions to approved plans (FPC2017-0052) FPContractor: LOW VOLTAGE FIRE INC 1090 JOSHUA WAY, # UNIT A VISTA, CA 92081-7800 (760) 598-4110 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE SPRINKLER SYSTEM SUBMITTAL L CX w%ttc I ri t g r ci t s y S t m S FIRE ALARMS SOUND • DATA S MEDIA S SECURITYS CCTV S ACCESS CONTROL FIRE SPRINKLER SYSTEM CARLSBAD EXECUTIVE SUITES 2292 FARADAY CARLSBAD CA 92008 LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE L VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: CIO, C16 # 791832 I. 4110-0041.- LowValtage integrated systems PHONE: (760) 598-4110 FAX: (760) 598-4107 PART DESCRIPTION MANUFACTURER CSFM LISTING XR-1 50FC SPRINKLER CONTROL PANEL W/ CELL DIALER DMP 7165-1157:0135 850D PULL STATION(EXISTING) DMP N/A 521 LX SMOKE DETECTOR(EXISTING) DMP N/A 630F ANNUNCIATOR(EXISTING) DMP N/A NS-121575W HORN/STROBE @ WALL(EXISTING) WHEELOCK N/A S Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 5 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. C10, C16#791832 email: kylea@sdlvis.com S Multi-Lingual menus available by user -- S Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash Updateable: No more firmware chips to replace Adaptive TechnologyTM - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. FARW iE1I1!!àiit_IL SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR55OFC Up to 142 two-wire smoke detector or fire initiating zones on XR1 5OFC Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection Up to .7 Amps 12 VDC supervised bell output Up to 506 fully-programmable Form C relays Serial 3 Digital Dialer or CID reporting to multiple receivers Eight communication paths between the panel and Central Station Built-in remote or on-site feature upgrade capability 12.000 event buffer Multiple on-board status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas, with common areas Output Groups: Maximum functionality—Minimum programming XRVI C/XR55ODNFC SYSTEM FEATURES All above listed System Features On-board Ethernet connection for Network Monitoring1M Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available .. XP150FC & XR550FC FIRE PANELS The XR150DFC and XR5500FC provide basic fire monitoring for any single site application. The XR1500NFC and XR5500NFC panels provide all the same basic fire monitoring as the XR1500FC and XR5500FC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACI NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. XR150FC/XR550FC TYPICAL NOTIFICATION/ANNUNCIATION 12 or 24 VDC NAC1 r 12or24VDC Sync Module Strobe Mini-Horn 12or24VDC NA C2 12 or 24 VDC C 2 Power Supply Sync Module Horn Strobe NA 505-12 or other 1 2/24VDC UL Motor Bell Commercial Fire Approved Digital 1 Digital SLC Power Supplies Annunciator Bus Loop I I Digital SLC Fire Command Additional 630F Any expansion device Loop 1 can operate on SLC Loop Centers 1 or2 630F Fire Command Center FIBLE COMMUNICATION Th'XR150DNFC and XR5500NFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time NETWC < OR CELLULAR Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. . and limit dependence on automation literal tables for message conversion. S PK SIM, E F T ,7777777777-- Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. FIRE DRILL AND ONE-MAN COMMUNICATION FUNCTION WALK TEST DIAGNOSTICS Users can test fire notification bells using The enhanced diagnostic menu enables the Fire Drill feature. A special code is also technicians to check network and cellular available for installers to test the system. The communication status, cell signal strength, one-man walk test feature allows a single and email status from the keypad. technician to check the panel response to fire, burglary, panic and supervisory zones. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, BUILT-IN PROGRAMMER For additional ftexht)6 keypads attached to presignal, cross zoning, or fire supervisory. AND DIAGNOSTICS the XR1 50FC and XR550FC panels can display This flexibility allows the ability to match No programming device is required, enabling keypad Status List and User Menu text using individual zone characteristics to the needs installers and service technicians to fully multiple languages. The user has the option of any area in the fire installation, program the system and run diagnostics from to select the language to use. any DMP LCD keypad. Check the electrical STATUS LIST ZONE EXPANSION state of zones, find individual zone numbers. To provide maximum system flexibility, fire The XR1 50FC and XR550FC provide up to 570 check the LX-Bus for Missing. Overlapping zones may be programmed to display at a zones, programmable for a variety of fire and/or Extra zones, and much more, all from specific keypad. In this manner, all fire zones applications. The system provides Class B any OMP LCD keypad. can be monitored in one location and other 12 VDC powered zones, two on-board and zones can be programmed to display and be four on the 715 Module, plus eight panel F DATEABLE monitored at different keypad locations. burglary zones. Up to 60 zones are available The XR150FC and XR550FC panels accept on l5 keypad addresses and uptolOozones software updates from a remote location 12,000 LLNr MEMORY are available on each built-in LX_BusTM using using Remote LinkTM software. When new Allows the user to view the last 10.000 Expansion Modules. XR150FC/XR550FC feature updates release. 14 , FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds afterthe reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. I.IUUI DL.LCC UI £,UUU 73tCIII even11101 perform the flash update remotely. occurred over the past 45 days. REMO K The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindowsTM. The XR150FC and XR550FC include an interface connection for installers to use to connect a laptop computer. EIGHT COMMUNICATION PATHS . NC, N CIRCUIT OUTI . - •• •.. E' . ON The XR150FC and XR550FC allow the use.. Easily add NAC outputs to the XR150FC/ of two SPOT relay outputs and four open XR55OFC system. Upto three Class Bmodules collector outputs, that may be activated by can be mounted within the FACR Model 865 or zone or system events, by schedule, through 866 Class B NAC Modules may be combined the User Menu or when a card is presented. with a power supply to provide additional 4 Output Groups allow multiple outputs to Amp NAC outputs. Use an 867 on the SLC activate with a single event and/or can be Loop to further expand NAC circuits. assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL fltPI ZkV KEYPADS 630F LCD Remote Fire Command - POWER SUPPLIES 505-12/LX 5 Amps @12VDC OM ESS TWO 505-12L 5 Amps @ 12VDC 1100X Receiver 505-12A 5 Amps @ 12 VOC 1100XH High Power Receiver S EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS ' 263C COMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (All require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module 'PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521 B/BXT Conventional Smoke, CleanMe 521 LX/L)ff Addressable Smoke/Heat, CleanMe ACCESr 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18" Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1R Network Enabled Receiver Compatabte with Central Station Receivers that accept Standard CID, DO, or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications 110OR Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VOC Battery Models 365, 366. 368 or 369 Output Rating Bell Up to .7 Amps at 12 VOC Smoke and Auxiliary Up to .5 Amps at 12 VOC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) LISTINGS AND APPROVALS Refer to the XR150FC/XR550FC Installation Guide (LT-1297), XR150FC/ XR550FC Programming Guide (LT-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. 2 a- 0, C 0 C 0 0 - ... QflflLL1 1)0") I .4n.sn ORDERING INFORMATION XR1500FC-R XR150 Fire Control Panel XR1 500NFC-R XR1 50 Fire Control Panel with Network XR550DFC-R XR550 Fire Control Panel XR55ODNFCR XR550 Fire Control Panel with -NetworL A® ii 25O( North Partnership Boulevard J . Designed. Engineered & Assembled Springfield. Missouri 65803-8877 ' in Springfield. Missouri CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. j7165-1157:0135 I Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models kR1501XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) orIFC (fire control)j Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders 716: Output Expander . 717: Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads I 263C1 2631-1: Cellular Communicator *(May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RFWireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter 1135: Wireless Siren *Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Rv' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. I *Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division _ L..Th ®Existing, shown for reference LISTED Simple operation provides instant alarmr The 850 Series Fire Alarm Pull stations offer quick and simple operation that's economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections Gold-plated contacts to avoid the risk of corrosion 0 [FOR7 AILAEI UflL STI3TiO1 8. &8S. FEATURES Approvals: UL and CSFM • Mounts on standard single-gang box Americans with Disabilities Act (ADA) compliant • Optional surface and weatherproof backboxes available Die-cast metal construction • High-gloss red enamel finish Reset key • Scored acrylic breakrod r M n IE S ra FJI?. E'cUJ n_ne.. E51T1T 0 (?) [NJ I DESCRIPTION The DMP 850 Series Fire Alarm Pull Station is a high quality, die-cast metal manual put( station available in either single-action or dual-action configurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 Amp ® 30 VDC. The contacts are gold-plated to avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COMPLIANCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. MOUNTING OPTIONS A variety of mounting options are available for the 850 series. It can be flush mounted to a standard single gang switch box or surface mounted in two optional configurations. The Model 850-SB Interior Surface Backbox or the Model 850-WP Weatherproof Backbox both allow conduit connection to the 850 Series Pull Stations. 8505 OPERATION The Model 850S Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-locking the station. 8SOD OPERATION On the Model 850D Dual Action Pull Station, the push bar rotates inward allowing the PULL handle to be grasped in a one handed motion. ADDRESSABLE ZONE To create an addressable reporting zone for the 850 Series, install a Model 711 Zone Expansion module. PULL Screw Terminals k To next To Fire Alarm - device or Control Panel - EOL resistor Model 850 Wiring Diagram 0 0 SPECIFICATIONS ORDERING INFORMATION Switch Rating 1 Amp @ 30 VDC 850S Single-action pull station Dimensions 4.75" H x 3.25" W x 2.25" D 850D Dual-action pull station Color Red w/raised white letters, white 850-SB Interior surface sheetmetal backbox PULL handle w/raised red letters 850-WP Weatherproof surface die-cast backbox COMPATIBILITY 850-AR Scored acrylic breakrods (1 dozen) The 850 Series Fire Pull Station is compatible with all 8505/711 Single-action pull station w/addressabte module DMP Command Processors. 850D/711 Dual-action pull station w/addressable module Note: All models are supplied with one scored acrylic breakrod and one key. DigitI Mnitming Proth.ct. 0 POI a 0 M' TM(NN I 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 ri 1Existing, shown for calculation e Conventional meets Analog The 521LX and LXT Smoke Detectors are the industry's first conventional smoke detectors with analog features. Remote maintenance reporting (CleanM&M) Drift compensation Multi-criteria detection Single-zone, addressable module . allowing LX-BusIII connection The 521 LXT also includes a heat sensor for fire detection. The multi-criteria, fast response, heat detector algorithms allow the 521 LXT to give fast responses to a broad range of fires. 52E 1[- &5 2fl17 FEATURES CteanMe remote maintenance reporting reduces false alarms Built-in drift compensation to reduce false alarms Field replaceable optical chamber for easy servicing LED indicates normal or CleanMe condition Easy 4-wire LX-Busm connection 521LXT includes multi-criteria heat detector Proven design ensures stability and performance Easy rotary addressing; no difficult binary switches 0 I CLEANMETM REMOTE MAINTENANCEJTROUBLE REPORTING FEATURE The 521LX/521LXT has a unique feature that allows the unit to send a signal when the smoke chamber has surpassed the UL Listed sensitivity range or if a hardware fault exists. In most cases the signal comes from the detectors becoming dirty over time and, as a result, are over-sensitive. This condition could cause false alarms. The CteanMel signal enables the panel to receive a service signal, allowing an installer time to clean the detector by replacing an inexpensive optical chamber with a new one. This service information can also be transmitted to the central station. DRIFT COMPENSATION BUILT-IN Built-in drift compensation means the 521LX/521LXT detectors automatically adjust their sensitivity, up to a maximum of 1.0% per foot, as they become dirty. This feature increases immunity to dust and dirt by 30-50%. SENSITIVITY LEVEL TEST MODE Each unit also includes a special sensitivity level test mode that is activated by holding a magnet near the internal reed switch for more than one second. Once the routine starts, the alarm LED flashes from one to nine times, indicating the actual unit sensitivity and whether service is required. COMPATIBLE WITH LX.BUSTM SYSTEMS The 521 LX/521 LXT can be used on the LX-Buslm of the XR2500F and XR1 00/ XR500 Series Command Processor Panels. Each detector connects to the 4-wire bus and uses one zone address. Addressing the detectors is simple using the two on-board rotary switches and a small slotted screwdriver. Up to 100 individual detectors can be supervised on one DMP LX-Bus. More than 40 detectors requires a Model 710 Bus Splitter! Repeater Module. HEAT DETECTOR IN SIILXT The multi-criteria 521 LXT photoelectric smoke detector also features a fixed rate-of-rise heat detector. The rate-of-rise detector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photoelectric smoke detector. As soon as the heat sensor detects a rapid rise in temperature, the sensitivity of the photoelectric sensor increases allowing it to detect smaller particles of combustion faster. IONS Operating Range 8.8tó 15.0 VDC Standby Current 8.8mA Alarm Current 28mA Maximum Ripple 10% (V) peak to peak Sensitivity Photoelectric 3.1% + 0.50 to 1.00% Operating Temperature 327 to 1007 Humidity Range 0 to 95% non-condensing RFI Immunity 20V!m minimum; 0 to 1000MHz Heat Sensor (LXI Only) Rate-of-Rise 157/min and> 1057 Fixed 135F Rate ofRise 15'F!min and >105F Power Up Time 15 seconds Drift Compensation 1.0%/ft. max. Detector Head Dimensions 5" Diameter, 2" Height Mounting Dimensions 4.75" Diameter, .3" Height Color White LISTINGS AND APPROVALS California State Fire Marshal (CSFM) UL 268 COMPATIBILITY The 521LX/521LXT Smoke Detectors are compatible with the following panels: XR2500F Addressable Fire Alarm Control Panel XR100/XR500 Series Command Processor Panels ACCESSORIES 521LXTPCB Replacement Smoke Detector Board 525 Replacement Optical Chamber 526 Smoke! in a Can ____ IiJr T P 0 (O11 o L 2500 North Partnership Boulevard Now Dg.t IMonitoring PrMuc" ? I Springfield, Missouri 65803-8877 SIGNALING Existing, shown for calculation (L y. MEA LISTED 11 V of off Is 11 11 1 1 [IJ DMP Fire Command Keypads provide a variety of fire annunciation solutions for residential and commercial fire applications. The 630F provides 32-character full text LCD display of system events and menu prompts for efficient, easy use. The keypads offer simple, one-button access to common features, including: Silence alarms Reset sensors Test the system Perform a fire drill The 692F includes a highly visible LED annunciator. 692w ftE? EFUEE KEY EPA E$ FIRE COMMAND FEATURES 692F FEATURES Simple harness connection to 4-wire keypad bus • Three status LEDs: Silenced, Trouble, and Power At-a-glance system status • 10 zone LEDs: 5 Trouble LEDs and 5 Alarm LEDs Powered from panel or auxiliary power supply a No addressing required - use as many as you need Optional backboxes for conduit or wall mount applications • Zone monitoring feature for all zones Attractive non-obtrusive designs • Four short tones indicate an unsuccessful keypad operation 2-button Panic keys a Quick key on keypad for changing user code Audible tone on each key press Zone LEDs: Normal, Trouble, 32-character LCD display Bypassed, and Alarm conditions Flush or Surface mount Keyswitch enables single button operation a Full operation with authorized code a Built-in diagnostics ' • AC Power, Trouble, Alarm LED Compatible with XR5FC/XR55L, XR100IXR500 Series, or : XR2500F a System events display in plain English o 630F REMOTE ANNUNCIATOR The 630F Fire Command Center offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. The backbox and trim frame provide an attractive installation. The keypad can either be flush- mounted or surface-mounted. 630F Keypad SINGLE-BUTTON OPERATION The 630F Fire Command Center has a factory installed keyswitch that enables the four function buttons—Alarm Silence, System Reset, System Test, and Fire Drill. The user can also access these four functions and many more through the User Menu by entering a valid user code. BUILT-IN DIAGNOSTICS An internal diagnostics program Lets installers and service technicians test the operation of the keypad at any time without disabling the system. SUPERVISED AND UNSUPERVISED OPERATION The 630F keypad can be programmed for supervised or unsupervised operation on the keypad data bus, increasing the overall number of keypads you can install, to provide maximum flexibility. When supervised, the keypad occupies its own address. Unsupervised operation allows you to instal[ multiple keypads on the bus with the same address. The 692F is always set as unsupervised. 692F FIRE COMMAND KEYPAD The 692F Fire Command Keypad offers highly visible LED annunciation of alarm and trouble conditions on DMP XR5FC and XR5SL Commercial Fire Panels. It provides individual zone alarm and trouble LEDs, status LEDs, an internal buzzer, 2-button functions. The 692F is cased in a durable Red plastic housing with a removable base for easy installation. 692F Keypad STATUS LEDS The Green Power LED lights when primary AC or DC power to the panel is at an acceptable level and flashes when its battery is low or missing. A Yellow Trouble LED turns on when either the panel has failed to communicate with the central station receiver or when phone line 1 or 2 is in a bad condition. The 692F also uses a Yellow Silenced LED to indicate when the panel Bell Output has been silenced. ZONE LEDS Zone LEDs indicate the status of the first five zones. Each zone has a trouble and alarm LED to indicate at-a-glance zone status. KEYPAD FUNCTION KEYS There are four clearly labeled function keys on the 692F keypad. The SILENCE, RESET, TEST, and CODE function keys allow the user to press one key to initiate operations. As an added security measure, the user must enter a valid security code after pressing one of the function keys. Fire Display lay Panic Keyboard User Operating OperatingCurrent Command Model Zones Type Keys Compatible Panels Red in Alarm Brightness Voltage Standby Alarm 630F None LCD Yes XR5FC/XR5SL, XR100IXR500 Series, No Yes 12 VDC 63mA 92mA XR2500F 692F i None i LED Yes XR5FC/XR5SL (First five zones only) No Yes 12 VDC 30mA 70mA 630F SPECIFICATIONS KEYPAD ACCESSORIES Operating Voltage 8.5 to 15 VDC 635 1.75" 630F Keypad Conduit Backbox 635F 2.5" 630F Keypad Conduit Backbox 695 1.5" Keypad Conduit Backbox Current Draw 63mA standby, 92mAmaximum j Irun 1-rame Dimensions 1U 4 w x /.U" ii xl í u Backbox Dimensions 8.75" W x 6.375" H x 2.5" D 696 1/2" Keypad Backbox Panel Compatibility XR500 Series, XRI 00 Series, 699 Keypad Deskstand XR2500F 300 4-wire Replacement Harness 692F spcicivnos LED Keypad Housing Operating Voltage 8.5 to 15 VDC LISTINGS AND APPROVALS Current Draw 30mA standby, 70mA maximum California State Fire Marshal (CSFM) Dimensions 6.8" W x 5.0" Fl x 1.1" D FCC Part 15 Panel Compatibility XR5FC and XR5SL Underwriters Laboratories (UL) Listed ANSI /UL 864 Control Units for Fire Protective Signaling ANSI/UL 985 Household Fire Warning For additional information, access www.dmp.com and select Compliance ° 1 I w1iiii ] 2500 North Partnership Boulevard Digital MnnitingProthct r •':j 'J Springfield, Missouri 65803-8877 n 00 COOPER Wheelock Existing, shown for calculation reference only. Series NS Horn Strobes and Series NH Horns C T •; . -. Series NS Description: The Series NS Horn Strobe Appliances are designed for indoor, wall and ceiling mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or the Wheelock patented Multi-candela strobe with field selectable candela settings of S 15/30/75/11Ocd for wall mount and 15130175/95cd and 115/177cd for ceiling mount. These versatile Horn Strobe Appliances can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8Mc Power Supply with the Wheelock patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA72/ANSl 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. The Wheelock patented 2-Wire Series NS Horn Strobes and Series NH Horns offer more features with lower current draw than competitors. NS and NH ceiling Mount Appliances will be available July 2006. <*> E5946 151-92-E 7125-0785:142 S5391 I( Series NH Features: Approvals include: UL Standard 1971, UL Standard 464, New York city (MEA), California State Fire Marshal (cSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant Complies with OSHA 29, Part 1910.165 Wall mount model Field Selectable Candela Setting 15/30/75/110cd (24 VDC Multi-Candela models) or 1575cd in 12 or 24 VDC Ceiling mount model Field Selectable Candela Setting 15/30/75/95cd and 115/177cd (24 VDC Multi-Candela models) Selectable Continuous Horn or Temporal (Code 3) 2 Selectable dBA settings of 90 and 95 dBA in both tones Patented Universal Mounting Plate 12 and 24 VDC models with UL Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Wall and Ceiling Mount Ceiling models with same look as Wheelock round ceiling strobes and speakers NH horn is selectable 12 or 24 VDC in 1 appliance The strobes can be synchronized using the Wheelock sync modules or power supplies with built in Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING .OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identity the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL Standard 1971 Model Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (CD) NS-24MCW 24 16.0-33.0 15/30/75/110 NS-241575W 24 16.0-33.0 15(75onAxis) NS-121575W 12 8.0-17.5 15 (75 on Axis) NS-24MCC 24 16.0-33.0 15/30/75/95 NS-24MCCH 24 16.0 -33.0 115/177 Table 2: dBA Ratings for Series NS/NH Horn Reverberant dBA Anechoic dBA 1 Oft per UL464 @lOft Description Volume 12 24 12 24 VDC VDC VDC VDC Continuous High 83 87 89 95 Low 76 81 84 90 Horn Code 3 High 79 82 89 95 Low 72 76 84 90 Horn L Table 3: UL Max Current* Series NS/NH Audible Wall Mount Strobe Models Ceiling Mount Strobe Models NH-12/24 NS-241575W 24 VDC NS-24MCW NS-24MCC NS-24MCCH @24VDC 15175cd 15cd 30cd75cd llOcd 15cd 30cd75cd 95cd 115cdk77cd High (95) dBA 24VDC 0.044 0.104 0.074 0.107 0.184 0.244 0.082 0.124 0.209 0.275 0.350 0.477 Low (90) dBA 24VDC 0.018 0.096 0.066 0.101 0.177 0.232 0.071 0.i140.201 0.261 0.306 0.429 Series NS/NH I2VDC Audible Wall Mount * RMS Current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max Current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NH-12/24 Aud/Strobe @I2V NS-121575W High (89) dBA 12 VDC 0.021 0.220 Low (84) dBA I2VDC 0.012 0.210 0 S Wiring Diagrams" NS/NH APPLIANCE TO NEXT PRECEDING APPLIANCE, SM/DS MT APPLIANCE OR EOLR FROM __FF PS-i2124-8MP, PS-12124-8CP OR FACP SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE SM F + STROBE - STROBE A robe Circuit NS C +A udible EOLR Audible - Audible NAC Circuit NOTE: NS/NH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to installation instruction (P83983, P83600 respectively). For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-1 2124-8CP and P84333 for PS-1 2/24-8MP. I SPECIFICATION & ORDERING INFORMATION Model Number Order Code Strobe Candela Sync WI SM, DSM OF PS-24-8MC 24 VDC 12 VDC Mounting Options# Agency Approvals - UL MEA - CSFM FM BFP NS-24MCW-FR 9404 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-24MCW-FW 9405 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-241575W-FR 7806 15(75onAxis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-241575W-FW 7811 15(75onAxis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-121575W-FR 7816 15(75onAxis) X -- X B,D,E,F,G,H,J,N,O,R,X X X X X X NS-121575W-FW 7818 15(75onAxis) X - X B,D,E,F,G,H,J,N,O,R,X X X X X X NH-12/24-R 7449 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X NH-12/24-W 7500 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X NS-24MCC-FR 3754 15/30/75/95 X X - E X * * X * NS-24MCC-FW 3753 15/30/75/95 X X - E X * * X * NS-24MCCH-FR 3756 115/177 X X - E X * * X * NS-24MCCH-FW 3755 115/177 X X - E X * * X * NH-12/24R-R 3752 - X - X B,D,E,F,G,H,J,N,OR,X X * * X * NH-12/24R-W 3751 - X - X B,D,E,F,G,H,J,NO,R,X X * * X * NS and NH Ceiling Mount Appliances will be available July 2006. *Pending Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible/visual notification appliances shall be Wheelock Series NS Horn Strobe appliances and Series NH Horn appliances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing- Impaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/110 candela. Where ceiling mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/95 candela or 115/177 candela. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with the Wheelock SM, DSM Sync Modules orthe Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Horn Strobes and NH horn shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. S "73 Branchport Avenue ong Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2100 NS/NH 09/06 SYSTEM RECORD OF COMPLETION QO This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. ' 5 Form Completion Date: 4/6/2017 Supplemental Pages Attached: 1/ ttj PROPERTY INFORMATION Name of property: Carlsbad Executive Suites Address: 2292 Faraday Description of property: B Occupancy, Single Story, Fully Sprinklered Name of property representative: Address: Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Low Voltage Integrated Systems Address: 1930 Watson Way, Ste L, Vista, CA 92081 Phone:' 760-598-4110 Fax: 760-598-4107 E-mail: Mikea@sdlvis.com Service organization: Same Address: Phone: Fax: E-mail: Testing organization: Address: Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: National Monitoring Center Address: Phone: 1-800-662-1711 Fax: E-mail: Account number: Al 5-8649 Phone line 1: Phone line 2: Means of transmission: Cellular Entity to which alarms are retransmitted: Carlsbad Fire Fept. Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a: ED New system 0 Modification to existing system Permit number: FPC2017-0078 NFPA 72 edition: 2016 4.1 Control Unit Manufacturer: DMP Model number: XR1 50-FC 4.2 Software and Firmware Firmware revision number: 3 4.3 Alarm Verification Z This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 3) SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120VAC Overcurrent protection: Type: Circuit Breaker Branch circuit disconnecting means location: Panel # 1 Control panel amps: Amps: 20 Number: #3 5.1.2 Secondary Power Type of secondary power: Standby Batteries - (2) 12VDC, 12AH Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit El This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line X B 1 Device Power. X B 1 Initiating Device X B 1 Notification Appliance X B 1 Other (specify): REMOTE ANNUNCIATORS Type Location Fire Annunciator I Ste 110 Entrance Fire Annunciator I East Entrance INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 2 Addressable Alarm Contact Smoke Detectors 1 Conventional Alarm Photoelectric Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches 1 Conventional Alarm Contact Tamper Switches 1 Conventional Supervisory Contact Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 20f3) SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible Combination Audible and Visible 2 SYSTEM _CONTROL _FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip INTERCONNECTED SYSTEMS This system does not have interconnected systems. El Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system he has been installed according to all NFPA standards cited herein. Signed: Printed name: Nick Truman ;a~~ Date: 4/6/2017 Organization: Low Voltage Integrated Sys. Title: Fire/Life Safety Tech Phone: 760-598-4110 12.2 System Operational Test This system has tested according to all NFPA standards cited herein. :as;specffiie~jherei Signed: _- Printed name: Nick Truman Date: 4/6/2017 Organization: Low Voltage Integrated Sys. Title: Fire/Life Safety Tech Phone: 760-598-4110 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Testing contractor representative: Property representative: AHJ representative: _______- j 4/6/2017, 9:30am Nick Truman Nick Truman Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale It may not be copied for commercial sale or distribution. (p. 3o13)