Loading...
HomeMy WebLinkAbout2210 FARADAY AVE; 120; FPC2018-0357; Permit11I4l:i1I.1:I (Q ty of Carlsbad Print Date: 04/20/2022 Permit No: FPC2018-0357 Job Address: 2210 FARADAY AVE, # 120, CARLSBAD, CA 92008-7225 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121205500 Track #: Applied: 10/30/2018 Valuation: $366,033.70 Lot #: Issued: 11/13/2018 Occupancy Group: Project #: Finaled Close Out: 11/07/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: GENMARK -FIRE SPRINKLER TI (14 HEADS) Applicant: ARROW AUTOMATIC FIRE SPRINKLER BRYON FULLER 9520 PATHWAY ST SANTEE, CA 92071-4169 (760) 438-4578 FPContractor: ARROW AUTOMATIC FIRE SPRINKLER INC 10973 SAN DIEGO MISSION RD SAN DIEGO, CA 92108-2431-SAN DIEGO (619) 448-2518 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov tq a Fire Protection Products Worldwide I www.tyco-fire.com Contacts Series DS-1 - 5.6 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprin- kler drops from unheated portions of buildings) sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g., sprin- kler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or hor- izontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) sprinklers are used on systems that are seasonably drained to avoid freezing (e.g., vacation resort areas) L'L.)IL.1 Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) TY3255 - Pendent 1Y3155 - Upright 1Y3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved TY3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-E LPCB Approved Reference No. 094a/11 CE Certified Certificate of Conformity No. 0832- CPD-2015 (Refer to Tables A and B for details.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1 inch NPT ISO 7-R 1 Discharge Coefficient K=5.6 gpm/p5i112 (80,6 1pm/barl'2) Temperature Ratings Refer to Tables A and B. Finishes Sprinkler: Refer to Table D. Escutcheon: Refer to Table D. JANUARY 2015 Physical Characteristics Inlet.........................Copper Plug ........................Copper Yoke ..................Stainless Steel Casing ........Galvanized Carbon Steel Insert .......................Bronze Bulb Seat ..............Stainless Steel Bulb (5 mm dia.) ................Glass Compression Screw............Bronze Deflector.....................Bronze Frame .......................Bronze Guide Tube.............Stainless Steel Water Tube.............Stainless Steel Spring.................Stainless Steel Sealing Assembly.......Beryllium Nickel w/TEFLON Escutcheon .............Carbon Steel TFP500 FPC20I8-0357 2210 FARADAY AVE #120 GENMARK- FIRE SPRINKLER TI (14 HEADS) 2121205500 10/30/2018 FPC20I 8-0357 TFP500 Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL I CHROME BRASS PLATED POLYESTER* PENDENT (TY3255) STANDARD 135°F(57°C) Orange 1, 2, 3, 4, 5:6 1, 2, 4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2, 3, 6 1, 2, 6 RECESSED 135°F (57°C) Orange 1,2,3,5 1,2,5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1,2 360°F (182°C) Mauve N/A DEEP 135°F(57°C) Orange 1,2,3,4,5 1,2,4,5 155-F (68-C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F(182°C) Mauve WITHOUT 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2, 3 1,2 UPRIGHT TY3155) WITHOUT 135°F (57°C) Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2, 3 1,2 Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB) and CE conformity s:p1y to these temperature ratings only Approved by the City of New York under MEA 352-01-C Approved by VdS Frame and deflector only N/A - Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER FINISH SPRINKLER ESCUTCHEON TEMPERATURE BULB NATURAL BRASS CHROME PLATED POLYESTER*** TYPE TYPE RATING COLOR CODE 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow STANDARD 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F(68°C) Red HSW* (1Y3355) DEEP 175°F (79°C) Yellow 1**, 2°°, 3*** 4 5 1°° 2°°, 4 5 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red 175'F(79-0) Yellow WITHOUT 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 2°, 5 1°°, 2°° Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB( and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-E * Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches (100 to 300 mm) Light and ordinary hazard occupancies only Light hazard occupancies only Frame and deflector only TABLE B SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING— INLET BAND WATER TUBE CASING GUIDE - INSERT TUBE BULB FRAME —> ", SEAT _- 5 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY WRENCH RECESS (t WRENCH FT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 WRENCH SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER 1/2 (12,7 to IN 1/4 INCR 4-1/ (108,0 FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON TFP500 Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS rj~14 FACE OF I CEILING 2-3/16" ± 1/8' 3" DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING 13/8 /17/8 DIA. (34,9±3,2 mm) FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING IL ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT (TY3155) WITHOUT ESCUTCHEON TFP500 Page 5 of 10 ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS 2-3/8 ±1/8 (60,3 ± 3,2 mm) FACE OF FACE OF SPRINKLER MOUNTING FITTING SURFACE B 4~~ (76,2 mm) 1-3/ SPRINKLER FITTING (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16 CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2"t045-3/4"(12,7t01162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 4-1/4' ± 1/8" - ' 2-1/2' DIA. FACE OF I (108,0 ± 3,2 mm) FACE OF (63,5 mm) 1 MOUNTING SPRINKLER H- FITTING SURFACE I )4 1 (88,9 mm) SPRINKLER FITTING / (REFER TO DESIGN CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48' (139,7 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS MINIMUM 2-1/4" (57,2 mm) FACE OF DEFLECTOR TO fl - SPRINKLER I MOUNTING SURFACE URFACE / 5/16' SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Ref. Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow- ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble listing or approval agency (e.g., UL Listing is based on NFPA 13 require- ments). For more information on LPCB Approval, contact Tyco Fire Suppres- sion & Building Products at the follow- ing office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 inch NPT Series DS-1 Dry-type Sprinklers in the 1 inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. TFP500 Page 6 of 10 Temperatures for Heated Area(1) Ambient Temperature () Discharge End of Sprinkler Minimum Exposed Barrel Length(2), Inches (mm) 40°F (4°C) 0 0 0 30°F (-1°C) 0 0 0 20°F 40 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 30 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: 1 For protected area temperatures that occur between values hated above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS You can also install Series DS-1 Dry- type Sprinklers in the 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1 inch NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 inch reducing tee when locating Series DS-1 Dry-type Sprinklers directly below the branchline; otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprin- klers and the branchline. Failure to do so may result in pipe freezing and water damage. NOTICE H Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Tyco Fire Protection Products (TFPP) Technical Services. Failure to use the appropriate fitting may result in one of the following: failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Pro- tection Association for dry pipe sprin- kler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when con- necting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprin- klers must be sealed. Due to tempera- ture differences between two areas, the potential for the formation of conden- sation in the sprinkler and subsequent ice build-up is increased. If this con- densation is not controlled, ice build-up can occur that might damage the dry- type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP500 Page 7 of 10 FACE OF SPRINKLER - FITTING Ir ' EXPOSURE LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES A FIGURE 11 EXPOSURE LENGTH RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) I DSB-2 1- * INTENDED FOR FREEZER ___________ • STRUCTURES FIGURE 12 SPRINKLER FITTING UNHEATED AREA TO WET SIDE SYSTEM OUTLET PLUGGED DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) -c 77 FIGURE 13 SPRINKLER FITTING HEATED AREA STRAP TIES ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4 DIA. -. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE - DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER 1-3/4' DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 \45 BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 8 of 10 Installation TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers must be installed in accordance with this section. General Instructions Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not Install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Notes: Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendicu- lar to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 1. With a non-hardening pipe- thread sealant such as TEFLON applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Ref. Figure 1) the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 2) Apply the wrench recess of the W-Type 7 Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutch- eon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response, Standard Cover- age Dry-type Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. SIGNAL WHITE 4 (RAL9003) POLYESTER CHROME PLATED I TEMPERATURE RATING(2) 0 135°F(57°C) 1 155°F(68°C) 2 175°F(79°C) 3 200°F (93°C) 4 286°F (141°C) 5 360°F (182°C) ESCUTCHEON FINISH(1) SIGNAL WHITE (RAL9003) POLYESTER SIGNAL WHITE (RAL9003) POLYESTER BRASS PLATED SIGNAL WHITE (RAL9003) POLYESTER CHROME PLATED ORDER LENGTH(3) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" TFPSOO Page 9 of 10 P/N* 60 - XXX - X - XXX SIN SPRINKLER _[ _L FINISH 96 Pendent with TY3255 CHROME Standard Escutcheon (1" NPT) (Figure 3) o PLATED 93 Pendent with TY3255 NATURAL Deep Escutcheon (1' NPT) (Figure 5) 1 - 97 Pendent with TY3255 BRASS Recessed Escutcheon (1" NPT) (Figure 4) 2 92 Pendent without TY3255 NATURAL Escutcheon (1" NPT) (Figure 6) BRASS Sidewall with TY3355 94 Standard Escutcheon (1" NPT) (Figure 8) 53 Sidewall with TY3355 Deep Escutcheon (1 NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon (1" NPT) (Figure 10) 98 Upright without I 1Y3155 I Escutcheon (1 NPT) (Figure 7) Notes: Escutcheon Finish applies to sprinklers provided with escutcheons. 360"F )182"C) temperature rating applies to non-recessed sprinkler assemblies. Dry-type Sprinklers are furnished based upon "Order Length" as mea- sured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. Use Prefix "I" for ISO 7-R1 Connection (e.g., 1-60-961-1-180). TABLED SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Dry-type Sprinklers When ordering Series DS-1 5.6K Pendent, Upright, and Horizontal Side- wall, Standard Response, Standard Coverage Dry-type Sprinklers, specify the following information: SIN: TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Order Length: Dry-type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections: 1 Inch NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Tyco Sales Representative.) Temperature Rating Sprinkler Finish Escutcheon Type and Finish, as applicable P/N from Table D Part numbers are for 1 inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhe- sive (a sufficient quantity for installing one boot). TFP500 Page 10 of 10 .1 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. - tiz'co TEFLON is trademark of the DuPont Corporation. Fire P,nte.-tinn Prnd,,,,t