Loading...
HomeMy WebLinkAbout2210 FARADAY AVE; 120; FPC2019-0180; PermitJ1 :1IIl11I.]:iI C`~~ity of Carlsbad 1 Print Date: 04/20/2022 Permit No: FPC2019-0180 Job Address: 2210 FARADAY AVE, # 120, CARLSBAD, CA 92008-7225 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121205500 Track #: Applied: 08/01/2019 Valuation: $366,033.70 Lot #: Issued: 08/20/2019 Occupancy Group: Project #: Finaled Close Out: 11/14/2019 #of Dwelling Units: Plan 1*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: GENMARK DX -SPRINKLER TI (32 HEADS) Applicant: FPContractor: ARROW AUTOMATIC FIRE SPRINKLER INC ARROW AUTOMATIC FIRE SPRINKLER INC HEATHER PAVLICK 10973 SAN DIEGO MISSION RD 9520 PATHWAY ST SAN DIEGO, CA 92108-2431-SAN DIEGO SANTEE, CA 92071-4169 (619) 448-2518 (619) 448-2518 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 01111112 Pendent F1/F2 11mabile ffC2_019 -DIO Bulletin 013 Rev. I Models Fl Series Standard Response Standard Spray Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/F1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentjFl/F2 Recessed Recessed XLH Upright Horizontal Sidewall Pendent/FP 111 XLH Recessed Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. XLH Pendent The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F142, F1XLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F156 K5.6 1/2" NPT See See F142 F1XLH K4.2 Standard (R1/2) 175 PSI 7PSl Temperature "Finish Table" Ratings' Table F128 K2.8 Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 DZR Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass OM Brass or CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US I Metric Upright I Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2' (15mm) ) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1,2,3,4 I RA1314 5 7/16" (10mm) 1/2" NPT (R1/2) 4.2 I 60 2.25" (57mm) 1 RA13232 I RA1313 3/8 (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1,2 RA1321 RA1311 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 80 57mm 3, 4 RA13755 Refer to Bulletin 024 for Special Response Sprinklers (F1 S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. FM Approved for SSU up to and including 200°F (930C). (( Polyester coated _PCB & VdS approved sprinkler RA1325, RA1314 & RA1375. Upright Pendent Conventional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers0) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2(15mm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) RA 1314 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1313 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1311 (1) Refer to escutcheon data table for approvals & dimensions 0 /0. ROLE OR. - ID/IC OR rnFA FACE OF ;:1OEOUION . ... AT MAXIMUM RECESS I125.4,,,mj AT ~k ROOM 2 RECESSED PENDENT W/fl OR F2 ESCUTCHEON WR000ON NOT FM APPROVED MVIII Fl ESCUICOCON Model F156, F142, F1XLH & F128 Fl or F2 N I/2 REDUCER 2 5/8 OP. (66.7,,,,,J HOLE IN CE/UNIT 2 5/IC OP. (58.7,mJ CUP FACE OF FITTING I IV FACE OP CEILING CEILING FACE I DIMENSION IAT MOD/MUM RECESS 112 T36-1 AT MINIMUM RECESS IT25.4,,s,,1 ~AT MON/MUM RECESS 9/I67I4.3,nm) ADJUSTMENT .3 I/4 MINIMUM RECESS I725.4mm] ( RECESSED PENDENT W/FP ESCUTCHEON -SPRINKLER NOT FM APPROVED +1110 FR ESCUTCHEON Model F156, F142, F1XLH & F128 FP 3. Vertical Sidewall Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Nominal Orifice Thread Size I Nominal K Factor I Sprinkler I Height I Approval (1) Organizations I I Identification Sprinkler I US I Metric Numbers (SIN) 1/2"(15mm) ½" NPT(R1/2) 5.6 8.0 2.25" (57mm) 1,2,3 LPC Approval is pendent only, 57°C through 141°C ratings. 121cULus Listed corrosion resistant (Polyester coated) sprinkler. 31cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. Model F156 Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench I FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS 1725.4mm] AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4719mm1 AT MINIMUM RECESS = 3/879.5mm] -2 I/4 -HOLE OLA. [57.2mm] I X 1/2 REDUCER - Fl ESCUTCHEON AT MAXIMUM RECESS 1-3/8734.9mm] AT MINIMUM RECESS 2-1/16752.4mm] - F2 ESCUTCHEON AT MM/MUM RECESS 1-5/8741.3mm] AT MINIMUM RECESS = 2-1/16752.4mm] [3.2mm] Ta' 5/i6 0414 / 4-I2 [101.6mm-304.8mml 49.2m Z 7/32 0/A CEILING TO [72.2mm] DEFLECTOR 7_n4 - TURN COLLAR UL TIGHT AGAINST SPRINKLER WRENCH BOSS. I Fl ESCUTCHEON I 3/4719mm] ADJUSTMENT 1/2712.7mm] ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (I) FM APPROVED FOR 4 - 6 [10 1.6MM - 152.4114M] CEILING TO DEFLECTOR. Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. Installation Data:Horizontal Sidewall Nominal K Factor ___________________ Sprinkler Height Approval Organizations Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2,63" (67mm) 1,2 1 1cULus Listed corrosion resistant (Polyester coated) sprinkler. 21cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. ')Polyester coated FM approved sprinkler. Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & Fl 28 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Associalion or the approving Authority Having Jusdic- tion Installation. Installation Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model Fl, F2, and EP Escutcheon illustrated are the only recessed escutcheon to be used with the Model Fl 56, Fl 42, Fl XLH & Fl 28 Recessed Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1 56, F1 42, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak light 1/2" NPT (R 112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating: - Specify when ordering - Model F156 Pendent Sprinkler Sprinkler Finish Escutcheon Finish (where applicable) Note: When Models F156, F142, F1X1_H & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (1) SIN: RA1 335- cuLus and FM permits use with Fl or F2 escutcheons for light hazard only. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1XLH & Fl 28 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to instal- lation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green Hight ) 141 286 225°F (107°C) Blue Extra High0> 182 360 1 300°F (149°C) Mauve (1) Not available for recessed Sprinklers. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finisht1 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6)(7)(9)White Painted Special Applition Finishes Sprinkler Escutcheon Bright Brass (2) Bright Brass Black Plated Black Plated Black Paint )3)(9) Black Paint Off White (3)(9) Off White Satin Chrome Satin Chrome Lead Plated )3)(4)(8) Wax Coated )3)(4)(5)(8) Wax Over Lead )3))4)(5X8) (1) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. 2 200°F (93°C) maximum. (1) UL and ULC listed only. 4 155°F to 200°F (68°C to 93°C) ratings only. 5 286°F (141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). cuLus listed "corrosion resistant" applies to SIN Number RA1 325 (Upright) RA1323 (upright), RA1 321 (Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approved finish as "Polyester Coated" applies only to SIN number RA1 314 & RA1 321 (Pendent) in standard black or white. FM Approved finish applies only to SIN number R.A1335 & RA1 385. LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1 375. 5. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles , Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled Reliabl (800 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 07/12 P/N 9999970299 SIN RA 7216 is Corrosion Resistant with White Polyester Coating. Model JL1 12 Pendent Model J112 Pendent (R 7216) (RA 7216) Rellmabi Bulletin 172 Rev.B Model JL1 12 &J112-Pendent ECLH - Extended Coverage Ught Hazard ECOH - Extended Coverage Ordinary Hazard ECOH - Extended Coverage Ordinary Hazard - Quick Response Model JL1 12 & J112 ECLH/ECOH Pendent & Recessed Pendent (SIN R7216 - Link and RA7216 - Bulb) Quick Response for Light Hazard (20'x 20'- 16'x 16' Room sizes) Quick Response for Ordinary Hazard (14 x 14' - 12' x 12' Room sizes) Standard Response for Ordinary Hazard (20' x 20' - 16' x 16' Room sizes) Features Extended Coverage Ordinary Hazard and Light Hazard protection to 400 ft2 (37.2m2) per sprinkler. Nominal K = 11.2 (160). Available in Pendent or Recessed Pendent styles. Recessed pendent version provides 3/4" (19mm) adjustment to flush pendent position (see adjustment table). Available in brass, chrome and polyester coated finishes. For applications as per NFPA 13. Approvals Organizations Underwriters Laboratories, Inc. (UL) Underwriters Laboratories of Canada (cULus) UL Listing Category Sprinklers, Automatic and Open Extended Coverage Sprinklers-Ordinary Hazard Occupancy UL Guide Number - VNIV. The Reliable Model JL112 and J112 sprinkler are Extended Coverage Sprinklers for use in both Light and Ordinary Hazard 1 and 2 occupancies with a coverage area of up to 400 square feet per sprinkler. For ordinary hazard applications it is a Standard Response Sprinkler. For light hazard applications it is Quick Response Sprinkler. The use of ECLH/ECOH sprinklers can provide lower installation costs by requiring fewer sprinklers, less piping and reduced labor. ECLH/ECOH sprinklers are to be installed according to the design criteria shown in this bulletin, NFPA 13, and all other local codes and ordinances. Flows and pressures as shown on pages 2 and 3 of this bulletin, must be used for the appropriate spacing and for the designated hazard classifications. This ECLH/ECOH sprinkler is available in various finishes, which includes a white polyester corrosion resistant finish. ECLH/ECOH sprinklers are available in a pendent or an attractive recessed pendent type which provides up to 3/4" (19mm) of escutcheon adjustment. Design Criteria Reliable Model JL1 12 & J 112 ECLH/ECOH sprinklers shall only be used in systems designed and installed in accordance with NFPA 13 and all other local codes and ordinances. The following design criteria also apply: Minimum sprinkler spacing is 8 ft. Sprinklers have a minimum flow requirement for each spacing as shown in the Flow Requirements Table on the reverse side. ECOH sprinklers are only to be used in system hydraulically designed per NFPA 13 for a minimum area of 1500 ft2 or 5 sprinklers, whichever is greater. Deflector to commodity clearance shall be a minimum of 18 in (457mm). ECOH sprinklers shall be installed in unobstructed constructions as defined in NFPA 13. For open web truss construction web thickness is not to exceed 1 inch. ECOH sprinklers which are installed above the bottom of a horizontal obstruction, shall have their deflectors located as shown in the Obstruction Table on page 3. Sprinklers can be installed under a sloping ceiling not exceeding 2 inches of rise in 12 inches. Maximum working pressure is 175 psi at the sprinkler. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford NY 10523 Sprinkler Model Specifications Temperature Rating Max.Ceiling Temp. Maximum Maximum THD Sprinkler Model Type Sprinkler Coverage Size Approvals °F °C °C Spacing Area JL1 12 ECLH/ECOH- R7216 Link/Pendent 165 74 100 38 20 400 f? JL1 12 ECLH/ECOH- R7216 Link/Recessed 212 100 150 66 J112 ECLH/ECOH- RA7216 Bulb/Pendent 155 68 100 38 20 400 ft2 NPT 1,2 J112 ECLH/ECOH- RA7216 Bulb/Recessed 200 93 150 66 (1) For metric equivalent see ConverLion Table. Flow Requirements - Ordinary Hazard - Standard Response Spacing Coverage Area Ordinary Hazard 1 Ordinary Hazard 2 K Factor 0.15 gpm/ft2 Density 0.20 gpmlft2 Density *Flow *Pressure *Flow *Pressure US Metric 16x16 256 ft' 39 12.1 51 20.7 18x 18 324 ft2 49 19.1 65 I 33.7 11.2 160.0 20x20 400 ft2 60 28.7 80 51.0 * Flow is in gpm and pressure is in psi (1) For metric equivalent see Conversion Table. Flow Requirements - Ordinary Hazard - Quick Response Spacing Coverage Area Ordinary Hazard 1 Ordinary Hazard 2 K Factor 0.20 gpmlft2 Density 0.15 gpm/ft2 Density *Flow I Pressure *Flow *Pressure US Metric 14x14 196 ft' 30 7.2 39 12.1 11.2 160.0 12'x 12 144 ft2 * Flow is in gpm and pressure is in psi (1) For metric equivalent see Conversion Table. (1) Conversion Table 1 in = 25.4 mm 1 gpm = 3.785 1pm 1 ft = 0.3048 m 1 gpm/ft2 = 40.74 mm/mim 1 ft2 = 0.093 m2 1 psi = 0.6895 bar Recessed Pendent ECLH/ECOH Adjustments Escutcheon ECLH ECOH R7216 RA7216 R7216 RA7216 FR ~ ~ ~ 3/4 El n/a n/a 3/4 3/4 F2 ½ ½ n/a n/a * Adjustments in inches. (1) For metric equivalent see Conversion Table below. Finishes Recess Escutcheons F1/F2 FP Model Ji Sprinkler Wrench Use Model J1 Wrench for JL1 12 & J112 ECLH/ECOH Pendent Sprinkler Removal and Installation Model J112 Sprinkler Wrench Use Model J112 Wrench for JL1 12 & J112 ECLH/ECOH Recessed Sprinkler Removal and Installation Sprinkler Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White Polyester Coated White Painted 2. Ji J112 Wrench Ordering Information Sprinkler Model Temperature Rating Finish Escutcheon and finish (where applicable) Corrosion Resistant J1 12 ECLH/ECOH Bulb °C 155 200 68 93 Minimum Flow Requirements For Earlier Editions of NFPA 13 - FOR REFERENCE ONLY NFPA13 -1991 Requirements NFPA13- 1989 Requirements K Factor Cove,a Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 3 Spacing Area g 0.15 gpm/ft2 0.20 gpm/ft2 0.16 gpmlft2 0.19 gpm/ft2 0.21 gpM/ft2 Density Density Density Density Density US Metric *Flow *Pressure *Flow *Pressure *Flow *Pressure ¶10w *Pressure *Flow *Pressure d:s 196 ft2 30.2 7.0 39.2 11.9 31.4 7.6 37.3 10.7 41.2 13.0 16'x 16 256 ft2 38.4 11.4 51.2 20.2 41.0 12.9 48.7 18.2 53.8 22.3 11.4 164.4 18x 18 324 ft2 48.6 18.2 64.8 32.3 51.9 20.7 61.6 29.2 68.0 35.7 20 x 20 400 ft2 60.0 27.7 80.0 49.3 64.0 31.5 76.0 44.5 84.0 54,3 *Flow is in gpm and pressure is in psi (1) For metric equivalent see Conversion Table. Flow Requirements - Light Hazard - Quick Response Spacing Coverage Area Flow (gpm) Pressure (psi) K Factor US Metric 16'x 16 256 ft2 30 7.2 11.2 12.8 160.0 18x18 324w 33 8.7 20'x 20 400 ft2 40 (1) For metric equivalent see Conversion Table. 3. Installation Requirements for Under Concrete Tees - cULus The stems of the concrete tee construction must be spaced at less than 7.5 feet (2.3m) on center but more than 3 feet (0,9m) on center. The depth of the concrete tees must not exceed 30 inches (762mm). The maximum permitted concrete tee length is 32 feet (9,8m); however, where the concrete tee length exceeds 32 feet (9;8m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA13 for extended coverage upright sprinkler applies. Location of Deflector to Horizontal Obstruction Distance from Sprinkler to Side of Obstruction Maximum Allowable Distance Deflector Above Bottom of Obstruction Lessthan 1'.......................................................0" 1'to less than l'-6 ............................................ 0" 1'-6"to less than 2 ........................................... 1" 2' to less than 2'- 6............................................1 2'-6"to less than 3 ........................................... 1 3' to less than 3'- 6'..........................................3" 4' to less than 4'- 6 ............................................ 5" 4'- 6' to less than 5' ..........................................7" 5' to less than 5'- 6 .. .........................................7" 5'- 6" to less than 6' .........................................7" 6' to less than 6'- 6" .........................................9" 6'-6'to less than 7' ........................................11" 7' and greater ..................................................14" (1) For metric equivalents see Conversion Table. Fig. 1 - Fl Escutcheon Solder Link .Bulb Classification OF °C Classification OF °C Bulb Color Ordinary 165 74 Ordinary 155 68 Red Intermediate 212 100 Intermediate 200 93 Green The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the united States, Canada and foreign countries. Manufactured by Reliableo The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address 0 Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03/08 P/N 9999970310