HomeMy WebLinkAbout2210 FARADAY AVE; 120; FPC2019-0180; PermitJ1 :1IIl11I.]:iI C`~~ity of
Carlsbad
1
Print Date: 04/20/2022 Permit No: FPC2019-0180
Job Address: 2210 FARADAY AVE, # 120, CARLSBAD, CA 92008-7225 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2121205500 Track #: Applied: 08/01/2019
Valuation: $366,033.70 Lot #: Issued: 08/20/2019
Occupancy Group: Project #: Finaled Close Out: 11/14/2019
#of Dwelling Units: Plan 1*:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check #: Final Inspection:
Project Title:
Description: GENMARK DX -SPRINKLER TI (32 HEADS)
Applicant: FPContractor:
ARROW AUTOMATIC FIRE SPRINKLER INC ARROW AUTOMATIC FIRE SPRINKLER INC
HEATHER PAVLICK 10973 SAN DIEGO MISSION RD
9520 PATHWAY ST SAN DIEGO, CA 92108-2431-SAN DIEGO
SANTEE, CA 92071-4169 (619) 448-2518
(619) 448-2518
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov
01111112
Pendent F1/F2
11mabile
ffC2_019 -DIO Bulletin 013 Rev. I
Models Fl Series
Standard Response
Standard Spray
Model F156 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
Model F156 Recessed Sprinkler Types
Pendent/F1/F2/FP
Horizontal Sidewall
Model F142, F1XLH & F128 Sprinkler Types
Standard Upright
Standard Pendent
Model F142, F1XLH & F128 Recessed Sprinkler
Types
Pendent/F1/F2/FP
Approval Organizations
Underwriters Laboratories Inc. and certified for
Canada (cULus)
Factory Mutual Approvals (FM)
Loss Prevention Council (LPCB, UK)
VdS Schadenverhutung GmbH
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Product Description
The F156, F142, F1XLH & F128 Series Glass Bulb
Sprinkler combines the durability of a standard sprinkler
with the attractive low profile of a decorative sprinkler.
Whether installed on exposed piping or in an office ceil-
ing, it is functional and attractive.
Beautifully versatile is the description for the Reliable
Models F156, F142, F1XLH & F128 Series Recessed
glass bulb sprinkler. Recessing the F156, F142, F1XLH &
F128 Series enhances its already low profile decorative
appearance, and facilitates a rapid and perfect installa-
tion.
The recessed escutcheon of the Models F156, F142,
F1XLH & F128 are highly adjustable. The two piece con-
struction makes field installation a very easy and rapid
task. This also allows ceiling panels to later be removed
without shutting down the fire protection system, thus fa-
cilitating maintenance of above ceiling services.
Upright Pendent Conventional
Vertical Sidewall Horizontal Sidewall Recessed
PendentjFl/F2
Recessed Recessed XLH Upright
Horizontal Sidewall Pendent/FP
111
XLH Recessed
Pendent FP
The F156, F142, F1XLH & F128 Series Automatic Sprin-
kler utilizes a 5.0 mm frangible glass bulb. The glass bulb
consists of an accurately controlled amount of special
fluid hermetically sealed inside a precisely manufactured
glass capsule. This glass bulb is specially constructed to
provide fast thermal response.
At normal temperatures, the glass bulb contains the
fluid in both the liquid phase and in the vapor phase. The
vapor phase can be seen as a small bubble. As heat is
applied, the liquid expands forcing the bubble smaller
and smaller as the liquid pressure increases. Continued
heating forces the liquid to push out against the bulb,
causing the glass to shatter, opening the waterway and
allowing the deflector to distribute the discharging water.
The F156, F142, F1XLH & F128 Series Sprinkler tem-
perature rating is identified by the color of the glass bulb
capsule as well as frame color where applicable.
XLH Pendent
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F142, F1XLH Upright
Technical data:
Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish
Pressure Pressure
F156 K5.6
1/2" NPT See See F142
F1XLH K4.2 Standard (R1/2) 175 PSI 7PSl Temperature "Finish Table" Ratings' Table
F128 K2.8
Material Data:
Frame Deflector Load Screw Pintle Cup Washer Bulb
CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 DZR Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass OM Brass or
CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
2.
Model F156, Upright, Pendent & Conventional Sprinklers
Model F142, F1XLH & F128 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
Nominal K Factor Sprinkler
Height
Approval
Organization
Sprinkler Identification Number
(SIN)
US I Metric Upright I Pendent
Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position
1/2' (15mm) ) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1,2,3,4 I RA1314 5
7/16" (10mm) 1/2" NPT (R1/2) 4.2 I 60 2.25" (57mm) 1 RA13232 I RA1313
3/8 (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1,2 RA1321 RA1311
Conventional-Install in Upright or Pendent Position
15mm (1) 1/2" NPT (R1/2) 5.6 80 57mm 3, 4 RA13755
Refer to Bulletin 024 for Special Response Sprinklers (F1 S5-56)
cULus Listed corrosion resistant (Polyester coated) sprinkler.
Polyester coated FM Approved sprinkler.
FM Approved for SSU up to and including 200°F (930C).
(( Polyester coated _PCB & VdS approved sprinkler RA1325, RA1314 & RA1375.
Upright Pendent Conventional
Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers0)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2(15mm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) RA 1314
7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1313
3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1311
(1) Refer to escutcheon data table for approvals & dimensions
0 /0. ROLE OR.
-
ID/IC OR
rnFA FACE OF ;:1OEOUION
. ... AT MAXIMUM RECESS I125.4,,,mj
AT ~k ROOM
2
RECESSED PENDENT W/fl OR F2 ESCUTCHEON
WR000ON NOT FM APPROVED MVIII Fl ESCUICOCON
Model F156, F142, F1XLH & F128 Fl or F2
N I/2 REDUCER
2 5/8 OP. (66.7,,,,,J HOLE IN CE/UNIT
2 5/IC OP. (58.7,mJ CUP
FACE OF FITTING I IV FACE OP CEILING
CEILING FACE
I DIMENSION
IAT MOD/MUM RECESS 112 T36-1
AT MINIMUM RECESS IT25.4,,s,,1
~AT MON/MUM RECESS 9/I67I4.3,nm)
ADJUSTMENT
.3 I/4
MINIMUM RECESS I725.4mm]
(
RECESSED PENDENT W/FP ESCUTCHEON
-SPRINKLER NOT FM APPROVED +1110 FR ESCUTCHEON
Model F156, F142, F1XLH & F128 FP
3.
Vertical Sidewall
Model F156 Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
U.S. Patent No. 6,374,920
Sprinkler Type Deflector to Ceiling Distance
(Min. - Max.)
Upright 4" (102mm) - 12" (305mm)
Pendent 4" (102mm) - 12" (305mm)
Installation Data:
Nominal
Orifice Thread Size
I Nominal K Factor
I Sprinkler
I Height
I Approval (1)
Organizations I
I
Identification
Sprinkler
I US I Metric Numbers (SIN)
1/2"(15mm) ½" NPT(R1/2) 5.6 8.0 2.25" (57mm) 1,2,3
LPC Approval is pendent only, 57°C through 141°C ratings.
121cULus Listed corrosion resistant (Polyester coated) sprinkler.
31cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead.
Model F156 Horizontal Sidewall Sprinkler
Deflector: HSW
Installation Wrench: Model D Sprinkler Wrench I
FACE OF FITTING TO FACE OF CEILING DIMENSION
Fl ESCUTCHEON
AT MAXIMUM RECESS 1725.4mm]
AT MINIMUM RECESS 3/879.5mm]
F2 ESCUTCHEON
AT MAXIMUM RECESS 3/4719mm1
AT MINIMUM RECESS = 3/879.5mm]
-2 I/4 -HOLE OLA.
[57.2mm]
I X 1/2 REDUCER -
Fl ESCUTCHEON
AT MAXIMUM RECESS 1-3/8734.9mm]
AT MINIMUM RECESS 2-1/16752.4mm]
- F2 ESCUTCHEON
AT MM/MUM RECESS 1-5/8741.3mm]
AT MINIMUM RECESS = 2-1/16752.4mm]
[3.2mm]
Ta'
5/i6 0414 /
4-I2
[101.6mm-304.8mml 49.2m Z 7/32 0/A CEILING TO [72.2mm] DEFLECTOR
7_n4 - TURN COLLAR UL
TIGHT AGAINST SPRINKLER WRENCH BOSS. I Fl ESCUTCHEON
I 3/4719mm] ADJUSTMENT
1/2712.7mm] ADJUSTMENT
RECESSED HSW W/F1 OR F2 ESCUTCHEON
(I) FM APPROVED FOR 4 - 6 [10 1.6MM - 152.4114M] CEILING TO DEFLECTOR.
Horizontal Sidewall
Note: For Recessed HSW Sprinklers use installation wrench GFR2.
Installation Data:Horizontal Sidewall
Nominal K Factor
___________________
Sprinkler
Height Approval Organizations Sprinkler
Nominal Orifice Thread Size Identification
US Metric Light Hazard Ordinary Numbers (SIN) Hazard
½" (15mm) ½" NPT (R1/2) 5.6 80 2,63" (67mm) 1,2 1
1cULus Listed corrosion resistant (Polyester coated) sprinkler.
21cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead.
')Polyester coated FM approved sprinkler.
Application
Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH &
Fl 28 Recessed sprinklers are used in fixed fire protection systems:
Wet, Dry Deluge or Preaction. Care must exercised that the orifice
size, temperature rating, deflector style and sprinkler type are in ac-
cordance with the latest published standards of the National Fire
Protection Associalion or the approving Authority Having Jusdic-
tion Installation.
Installation
Model F156, F142, F1XLH & F128 Series sprinklers are standard
response sprinklers intended for installation as specified in NFPA
13. They must also be installed with the Model D Sprinkler Wrench
specifically designed by Reliable for use with these sprinklers.
The Model F156, F142, F1XLH & F128 Recessed Sprinklers
are to be installed with a maximum recess of 3/4 inch (19mm). The
Model Fl, F2, and EP Escutcheon illustrated are the only recessed
escutcheon to be used with the Model Fl 56, Fl 42, Fl XLH & Fl 28
Recessed Sprinklers. The use of any other recessed escutcheon
will void all approvals and negate all warranties. When installing
Model F1 56, F1 42, F1XLH & F128 Recessed Sprinklers use the
Model GFR2 Sprinkler Wrench. Any other type of wrench may
damage these sprinklers.
Note: A leak light 1/2" NPT (R 112) sprinkler joint can be obtained with
a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers
over maximum recommended torque. It may cause leakage or
impairment of the sprinklers.
Glass bulb sprinklers have orange covers to protect the bulb dur-
ing the installation process. REMOVE THIS PROTECTION ONLY
AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED
AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN
INSTALLED. RASCO wrenches are designed to install sprinklers
when covers are in place.
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Deflector Type
Temperature Rating:
- Specify when ordering
- Model F156 Pendent Sprinkler
Sprinkler Finish
Escutcheon Finish (where applicable)
Note: When Models F156, F142, F1X1_H & F128 Recessed Sprinklers
are ordered, the sprinklers and escutcheons are packaged separately.
Escutcheon Data (1)
(1) SIN: RA1 335- cuLus and FM permits use with Fl or F2 escutcheons for light
hazard only.
Maintenance
The Model F156, F142, F1XLH & Model F156, F142, F1XLH
& Fl 28 Recessed Sprinklers should be inspected quarterly and
the sprinkler system maintained in accordance with NFPA 25.
Do not clean sprinklers with soap and water, ammonia or any
other cleaning fluid. Remove any sprinkler which has been
painted (other than factory applied) or damaged in any way A
stock of spare sprinklers should be maintained to allow quick
replacement of damaged or operated sprinklers. Prior to instal-
lation, sprinklers should be maintained in the original cartons
and packaging until used to minimize the potential for damage
to sprinklers that would cause improper operation or non-oper-
ation.
Temperature Ratings
Classification
Sprinkler
Temperature Max. Ambient
Temp.
Bulb
Color
Ordinary 57 135 100°F(38°C) Orange
Ordinary 68 155 100°F(38°C) Red
Intermediate 79 175 150°F (66°C) Yellow
Intermediate 93 200 150°F (66°C) Green
Hight ) 141 286 225°F (107°C) Blue
Extra High0> 182 360 1 300°F (149°C) Mauve
(1) Not available for recessed Sprinklers.
Maximum Working Pressure
175 psi (12 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Finisht1
Standard Finishes
Sprinkler Escutcheon
Bronze Brass
Chrome Chrome
Polyester Coated (6)(7)(9)White Painted
Special Applition Finishes
Sprinkler Escutcheon
Bright Brass (2) Bright Brass
Black Plated Black Plated
Black Paint )3)(9) Black Paint
Off White (3)(9) Off White
Satin Chrome Satin Chrome
Lead Plated )3)(4)(8)
Wax Coated )3)(4)(5)(8)
Wax Over Lead )3))4)(5X8)
(1) Other colors and finishes are available on special order. Consult factory for
details. Custom color painted sprinklers may not retain their UL Corrosion
resistance listing.
2 200°F (93°C) maximum.
(1) UL and ULC listed only.
4 155°F to 200°F (68°C to 93°C) ratings only.
5 286°F (141°C) sprinklers may be coated for ambient conditions not exceeding
150°F (66°C).
cuLus listed "corrosion resistant" applies to SIN Number RA1 325 (Upright)
RA1323 (upright), RA1 321 (Upright), RA1335 (HSW), RA1385(VSW) and
RA1314 (Pendent) in standard black or white. Corrosion resistance in other
polyester colors is available upon request.
FM Approved finish as "Polyester Coated" applies only to SIN number
RA1 314 & RA1 321 (Pendent) in standard black or white.
FM Approved finish applies only to SIN number R.A1335 & RA1 385.
LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1 375.
5.
Reliable...For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Automatic sprinklers
Flush automatic sprinklers
Recessed automatic sprinklers
Concealed automatic sprinklers
Adjustable automatic sprinklers
Dry automatic sprinklers
Intermediate level sprinklers
Open sprinklers
Spray nozzles
, Alarm valves
Retarding chambers
Dry pipe valves
Accelerators for dry pipe valves
Mechanical sprinkler alarms
Electrical sprinkler alarm switches
Water flow detectors
Deluge valves
Detector check valves
Check valves
Electrical system
Sprinkler emergency cabinets
Sprinkler wrenches
Sprinkler escutcheons and guards
Inspectors test connections
Sight drains
Ball drips and drum drips
Control valve seals
Air maintenance devices
Air compressors
Pressure gauges
Identification signs
Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc. Recycled Reliabl (800 431-1588 Sales Offices Paper
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices Revision lines indicate updated or new data.
www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 07/12 P/N 9999970299
SIN RA 7216 is Corrosion Resistant with White
Polyester Coating.
Model JL1 12 Pendent Model J112 Pendent
(R 7216) (RA 7216)
Rellmabi
Bulletin 172 Rev.B
Model JL1 12 &J112-Pendent
ECLH - Extended Coverage Ught Hazard
ECOH - Extended Coverage Ordinary Hazard
ECOH - Extended Coverage Ordinary
Hazard - Quick Response
Model JL1 12 & J112 ECLH/ECOH
Pendent & Recessed Pendent
(SIN R7216 - Link and RA7216 - Bulb)
Quick Response for Light Hazard
(20'x 20'- 16'x 16' Room sizes)
Quick Response for Ordinary Hazard
(14 x 14' - 12' x 12' Room sizes)
Standard Response for Ordinary Hazard
(20' x 20' - 16' x 16' Room sizes)
Features
Extended Coverage Ordinary Hazard and Light
Hazard protection to 400 ft2 (37.2m2) per sprinkler.
Nominal K = 11.2 (160).
Available in Pendent or Recessed Pendent styles.
Recessed pendent version provides 3/4" (19mm)
adjustment to flush pendent position (see
adjustment table).
Available in brass, chrome and polyester coated
finishes.
For applications as per NFPA 13.
Approvals Organizations
Underwriters Laboratories, Inc. (UL)
Underwriters Laboratories of Canada (cULus)
UL Listing Category
Sprinklers, Automatic and Open Extended Coverage
Sprinklers-Ordinary Hazard Occupancy UL Guide
Number - VNIV.
The Reliable Model JL112 and J112 sprinkler are
Extended Coverage Sprinklers for use in both Light
and Ordinary Hazard 1 and 2 occupancies with a
coverage area of up to 400 square feet per sprinkler.
For ordinary hazard applications it is a Standard
Response Sprinkler. For light hazard applications it is
Quick Response Sprinkler.
The use of ECLH/ECOH sprinklers can provide lower
installation costs by requiring fewer sprinklers, less
piping and reduced labor.
ECLH/ECOH sprinklers are to be installed according
to the design criteria shown in this bulletin, NFPA 13,
and all other local codes and ordinances. Flows and
pressures as shown on pages 2 and 3 of this bulletin,
must be used for the appropriate spacing and for the
designated hazard classifications.
This ECLH/ECOH sprinkler is available in various
finishes, which includes a white polyester corrosion
resistant finish.
ECLH/ECOH sprinklers are available in a pendent or
an attractive recessed pendent type which provides
up to 3/4" (19mm) of escutcheon adjustment.
Design Criteria
Reliable Model JL1 12 & J 112 ECLH/ECOH sprinklers
shall only be used in systems designed and installed in
accordance with NFPA 13 and all other local codes
and ordinances. The following design criteria also
apply:
Minimum sprinkler spacing is 8 ft.
Sprinklers have a minimum flow requirement for each
spacing as shown in the Flow Requirements Table on
the reverse side.
ECOH sprinklers are only to be used in system
hydraulically designed per NFPA 13 for a minimum
area of 1500 ft2 or 5 sprinklers, whichever is greater.
Deflector to commodity clearance shall be a
minimum of 18 in (457mm).
ECOH sprinklers shall be installed in unobstructed
constructions as defined in NFPA 13. For open web
truss construction web thickness is not to exceed 1
inch.
ECOH sprinklers which are installed above the
bottom of a horizontal obstruction, shall have their
deflectors located as shown in the Obstruction Table
on page 3.
Sprinklers can be installed under a sloping ceiling not
exceeding 2 inches of rise in 12 inches.
Maximum working pressure is 175 psi at the sprinkler.
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford NY 10523
Sprinkler Model Specifications
Temperature Rating Max.Ceiling Temp. Maximum Maximum THD Sprinkler Model Type Sprinkler Coverage Size Approvals
°F °C °C Spacing Area
JL1 12 ECLH/ECOH- R7216 Link/Pendent 165 74 100 38 20 400 f? JL1 12 ECLH/ECOH- R7216 Link/Recessed 212 100 150 66
J112 ECLH/ECOH- RA7216 Bulb/Pendent 155 68 100 38 20 400 ft2
NPT 1,2
J112 ECLH/ECOH- RA7216 Bulb/Recessed 200 93 150 66
(1) For metric equivalent see ConverLion Table.
Flow Requirements - Ordinary Hazard - Standard Response
Spacing Coverage
Area
Ordinary Hazard 1 Ordinary Hazard 2
K Factor 0.15 gpm/ft2 Density 0.20 gpmlft2 Density
*Flow *Pressure *Flow *Pressure US Metric
16x16 256 ft' 39 12.1 51 20.7
18x 18 324 ft2 49 19.1 65 I 33.7 11.2 160.0
20x20 400 ft2 60 28.7 80 51.0
* Flow is in gpm and pressure is in psi
(1) For metric equivalent see Conversion Table.
Flow Requirements - Ordinary Hazard - Quick Response
Spacing Coverage Area
Ordinary Hazard 1 Ordinary Hazard 2
K Factor 0.20 gpmlft2 Density 0.15 gpm/ft2 Density
*Flow I Pressure *Flow *Pressure US Metric
14x14 196 ft'
30 7.2 39 12.1 11.2 160.0 12'x 12 144 ft2
* Flow is in gpm and pressure is in psi
(1) For metric equivalent see Conversion Table. (1) Conversion Table
1 in = 25.4 mm 1 gpm = 3.785 1pm
1 ft = 0.3048 m 1 gpm/ft2 = 40.74 mm/mim
1 ft2 = 0.093 m2 1 psi = 0.6895 bar
Recessed Pendent ECLH/ECOH Adjustments
Escutcheon ECLH ECOH
R7216 RA7216 R7216 RA7216
FR ~ ~ ~ 3/4
El n/a n/a 3/4 3/4
F2 ½ ½ n/a n/a
* Adjustments in inches.
(1) For metric equivalent see Conversion Table below.
Finishes
Recess Escutcheons
F1/F2 FP
Model Ji
Sprinkler Wrench
Use Model J1 Wrench for
JL1 12 & J112 ECLH/ECOH
Pendent Sprinkler Removal
and Installation
Model J112
Sprinkler Wrench
Use Model J112 Wrench for
JL1 12 & J112 ECLH/ECOH
Recessed Sprinkler Removal
and Installation
Sprinkler Finishes
Sprinkler Escutcheon
Bronze Brass
Chrome Chrome
White Polyester Coated White Painted
2.
Ji J112 Wrench Ordering Information
Sprinkler Model
Temperature Rating
Finish
Escutcheon and finish (where applicable)
Corrosion Resistant
J1 12 ECLH/ECOH
Bulb
°C
155
200
68
93
Minimum Flow Requirements For Earlier Editions of NFPA 13 - FOR REFERENCE ONLY
NFPA13 -1991 Requirements NFPA13- 1989 Requirements K Factor
Cove,a
Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 3
Spacing Area
g
0.15 gpm/ft2 0.20 gpm/ft2 0.16 gpmlft2 0.19 gpm/ft2 0.21 gpM/ft2
Density Density Density Density Density US Metric
*Flow *Pressure *Flow *Pressure *Flow *Pressure ¶10w *Pressure *Flow *Pressure
d:s 196 ft2 30.2 7.0 39.2 11.9 31.4 7.6 37.3 10.7 41.2 13.0
16'x 16 256 ft2 38.4 11.4 51.2 20.2 41.0 12.9 48.7 18.2 53.8 22.3 11.4 164.4
18x 18 324 ft2 48.6 18.2 64.8 32.3 51.9 20.7 61.6 29.2 68.0 35.7
20 x 20 400 ft2 60.0 27.7 80.0 49.3 64.0 31.5 76.0 44.5 84.0 54,3
*Flow is in gpm and pressure is in psi
(1) For metric equivalent see Conversion Table.
Flow Requirements - Light Hazard - Quick Response
Spacing Coverage Area Flow
(gpm)
Pressure
(psi)
K Factor
US Metric
16'x 16 256 ft2 30 7.2
11.2
12.8
160.0 18x18 324w 33 8.7
20'x 20 400 ft2 40
(1) For metric equivalent see Conversion Table.
3.
Installation Requirements for Under Concrete Tees - cULus
The stems of the concrete tee construction must be spaced at less than 7.5 feet (2.3m) on center but more than 3
feet (0,9m) on center. The depth of the concrete tees must not exceed 30 inches (762mm). The maximum
permitted concrete tee length is 32 feet (9,8m); however, where the concrete tee length exceeds 32 feet (9;8m),
non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the
tees does not exceed 32 feet (9,8m) in length.
The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4mm) below the bottom of the
concrete tee stems.
When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4mm) beneath the bottom of
the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA13 for extended
coverage upright sprinkler applies.
Location of Deflector to Horizontal Obstruction
Distance from Sprinkler
to Side of Obstruction
Maximum Allowable Distance
Deflector Above Bottom of
Obstruction
Lessthan 1'.......................................................0"
1'to less than l'-6 ............................................ 0"
1'-6"to less than 2 ........................................... 1"
2' to less than 2'- 6............................................1
2'-6"to less than 3 ........................................... 1
3' to less than 3'- 6'..........................................3"
4' to less than 4'- 6 ............................................ 5"
4'- 6' to less than 5' ..........................................7"
5' to less than 5'- 6 .. .........................................7"
5'- 6" to less than 6' .........................................7"
6' to less than 6'- 6" .........................................9"
6'-6'to less than 7' ........................................11"
7' and greater ..................................................14"
(1) For metric equivalents see Conversion Table.
Fig. 1 - Fl Escutcheon
Solder Link .Bulb
Classification OF °C Classification OF °C Bulb Color
Ordinary 165 74 Ordinary 155 68 Red
Intermediate 212 100 Intermediate 200 93 Green
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable.
Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the united States, Canada and foreign countries.
Manufactured by
Reliableo
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
0 Recycled Paper
Revision lines indicate updated or new data.
EG. Printed in U.S.A. 03/08 P/N 9999970310