Loading...
HomeMy WebLinkAbout6200 AVENIDA ENCINAS; ; FS060014; PermitCity of Carlsbad Fixed Systems Permit Permit No: FS060014 6200 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: FIXSYS Applied 7/20/2006 Parcel No: Approved: 7/24/2006 Lot #: 0 Reference No.: Issued: 7/24/2006 PC #: Inspector: Project Title: ENCINAS WASTEWATER CHEMICAL AGENT SUPPR SYSTEM PLAN CHECK & INSPECTION Applicant: Owner: AIRGAS FIRE PROTECTION 9010 CLAIREMONT MESA BL SAN DEIGO, CA 858-495-2327 Fees ($) Add'l Fees ($) Total ($) Balance ($) 120 0 120 0 fSc*c'ot 4 UTI AIRGAS West Fire Protection 9010 CLAIREMONT MESA BLVD. SAN DIEGO, CA 92123 PHONE (858) 495-2327, FAX (858) 496-3820 ENCINAS WASTEWATER 6200 Avenida Encinas Carlsbad, CA 92009 SUBMITTAL FOR: ANSUL INERGEN (IG-541) Fire Suppression System File Server Room - #20-112 DESIGN BY: Gordon E. Swope SET NICET#7862 1 (Senior System Designer) 0 INERGEN FIRE SUPPRESSION SYSTEM 0 S AN L@ Ansul Device Compatibility Document Document 50054 04/05/2005 Rev: J 0 Circuit Specification AUTOPULSE 442R1D Initiating Loop Voltage: 17.5 - 26.5VDC Max Detector Loop Standby Current: 2.0mA/Loop Compatibility Identifier: 'A" NAC Power: Full Wave Rectified AUTOPULSE IQ-396 NAC Power: MPS-400 Filtered AUTOPULSE IQ- 301 NAC Power: Full Wave Rectified AUTOPULSE IQ- 636X (MMX-2, FZM-1) Compatibility Identifier: "A' NAC Power: Filtered Synchronizes System Sensor ADA horn/strobes APS-6R Use with the AUTOPULSE IQ- 301, AUTOPULSE IQ- 396, AUTOPULSE IQ- 636X control panels NAC Power: Filtered AVPS-24 .Use with the AUTOPULSE 10- 301, AUTOPULSE IQ- 396 control panels NAC Power: Full Wave Rectified FCPS-24 Field Charger Power Supply Input Voltage: 9 to 32 VDC 19.1 to 26.4VDC range for compatibility NAC Power: Filtered FCPS-24S6, FCPS-24S8 Field Charger! Power Supply Input Voltage: 9 to 32 VDC NAC Power: Filtered Selectable Strobe Synchronization for NACs (System Sensor, Geritex and Wheelock) MMX-2!FZM-1 (Notifier) Monitor Module Initiating Loop Voltage: 16 - 27.5 VDC Compatibility Identifier: "A" Ansul Device Compatibility Document Document 50054 Rev:J ECN 05-706 04/05/05 S FM-Approved Automatic Water Control Valves for PreAction and Deluge Sprinkler Applications (section not recognized by UL) AUTOPULSE 442R/D, AUTOPULSE IQ-301 AUTOPULSE IQ-396 AUTOPULSE IQ- 636X Solenoid Group [A] Skinner solenoid valve Model LV2LBX25, 24 VDC, 11 WATTS, 458 mA, 1/2 in. NPS, 5/8 in. orifice. Solenoid Group [B] These valves are interchangeable. ASCO solenoid valve Model T821 0A107, 24 VDC, 16.8 WATTS, 700 mA, 1/2 in. NPS, 5/8 in. orifice. ASCO solenoid valve Model R8210A107, 24 VDC, 16.8 WATTS, 700 mA, 1/2 in. NPS, 5/8 in. orifice. ASCO solenoid valve Model 8210A107, 24 VDC, 16.8 WATTS, 700 mA, 1/2 in. NPS, 5/8 in. orifice. Solenoid Group [C] Star Sprinkler Corp. Solenoid P/N 5550, 24 VDC, part of Model D deluge valve. Solenoid Group [D] ASCO solenoid valve Model 8210G207, 24 V dc, 10.6 WATTS, 440 mA, 1/2 in. NPS, 1/2 in. orifice. Solenoid Group [E] Skinner solenoid valve Model 73218BN4UNLVNOC1 11 C2, 24 V dc, 10 WATTS, 420 mA, 1/2 in. NPS, 5/8 in. orifice. Solenoid Group [F] Skinner solenoid valve Model 732 12BN4TNLVNOC322C2, 24 V dc, 22 WATTS, 1/2 in. NPS, 0.92 A. 250 psi (1725 kPa), 1/2 in. orifice. Solenoid Group [G] Skinner solenoid valve Model 71395SN2ENJ1NOH111C2, 24 V dc, 10 WATTS, 420 mA, 1 u4 in. NPS, 1/16 in. orifice, 250 psi (1725 kPa) rated working pressure. Ansul CV98 Electric Activator, P/N 423684; 24V, 0.9-1.6 ohms, 0.6 Amps Ansul CV-90 Electric Activator, P/N 426876,24VDC Ansul Current Limiter Module, P/N 427354 Ansul Electric Actuator P/N 73111, 24 VDC Ansul H Electric Actuator P/N 73327, 12 VDC Ansul Electric Actuator P/N 73097, 24 VDC Ansul Electric Activator, P/N 570537,24VDC Ansul AUTOMAN Il-C, P/N 31438, 24VDC Note: Refer to the FM approval guide for automatic water control valves that are compatible with solenoids listed above. Agent Releasing Applications Employ UL Listed and/or FM approved 24VDC solenoid for these Applications. (Refer to the appropriate panel installation manual to determine the available power output.) 2 Ansul Device Compatibility Document Document 50054 Rev: J ECN 05-706 04/05/05 S Table 7. Wheelock Notification Appliances (UL Listed) Control panels with notification circuits supplied by special purpose (FWR, filtered) power must use appliances listed in this table. Use only I2VDC devices with 12 volt control panels. WHEELOCK Rated Voltage2 FWR DC Filtered DC Sync. Module Notes: All current draws are shown in milliamperes and reflect worst case average. Nominal operating voltages shown. Refer to manufacturers installation instructions for more information. * Contact manufacturer for current draws. ** The strobe portion Wheelock 70021-24 Horn with Strobe 24VDC * * N/A Wheelock AES-DL1-LSM-24 Horn Strobe 24 VDC * * N/A Wheelock AES-DL1-WM-24-VF-R MultiTone Signals (ULC) 24VDC * * N/A Wheelock AES-EL1-LSM-24 Horn Strobe 24 VDC * * N/A Wheelock AES-EL1-WM-24-VF-R Multitone Signals 24VDC * * N/A Wheelock AH-24 Horn (ULC) 24VDC * * N/A Wheelock AH-24WP Horn (ULC) 24VDC * * N/A Wheelock AMT-24 Multitone Horn (ULC) 24VDC 48 48 N/A Wheelock AMT-2475-FR Horn Strobe (ULC) 24VDC 261max* 267max* N/A Wheelock AMT-24-IS-VFR Multitone Horn Strobe 24VDC 348 323 N/A Wheelock AMT-24-LS-VFR Multitone Horn Strobe (ULC) 24VDC 143 138 N/A Wheelock AMT-24-LSM-VFR Multitone Horn Strobe 24VDC 188 178 N/A Wheelock AS- 1215 Audible Strobe 12 VDC 311 252 SM/DSM Wheelock AS-121575 Audible Strobe 12 VDC 429 391 SM/DSM Wheelock AS-1230 Audible Strobe 12 VDC 413 355 SM/DSM Wheelock AS-2415 Audible Strobe 24 VDC 140 104 SM/DSM Wheelock AS-2415C Horn/Strobe (ULC) 24VDC 167 126 SM/DSM Wheelock AS-2415W Horn/Strobe (ULC) 24VDC 95 134 SM/DSM Wheelock AS-241575 Audible Strobe 24 VDC 162 121 SM/DSM Wheelock AS-241575W Horn/Strobe 24VDC 110 147 SM/DSM Wheelock AS-2430 Audible Strobe 24 VDC 190 148 SM/DSM Wheelock AS-2430C Horn/Strobe 24VDC 220 186 SM/DSM Wheelock AS-2430W Horn/Strobe 24VDC 135 177 SM/DSM Wheelock AS-2475 Audible Strobe 24 VDC 295 299 SM/DSM Wheelock AS-2475C Horn/Strobe (ULC) 24VDC 432 340 SM/DSM Wheelock AS-2475W Horn/Strobe (ULC) 24VDC 211 283 SM/DSM Wheelock AS-24100C Horn/Strobe (ULC) 24VDC 486 417 SM/DSM Wheelock AS-24110 Audible Strobe 24 VDC 443 333 SM/DSM Wheelock AS-24110W Horn/Strobe (ULC) 24VDC 242 326 SM/DSM Wheelock AS-24MCC Multi-Candela Audible Strobe 24 VDC 424 max* 330 max* SM/DSM** Wheelock AS-24MCW Audible Strobe Multi-Candela (ULC) 24 VDC 414 max* 280 max SM/DSM Wheelock ASWP-2475W Horn/Strobe 24VDC 187 186 SM/DSM Wheelock CH-CF1-LS-24-CFW Chime 24 VDC 101 100 SM/DSM Wheelock CH-CF1-MS-24-CFW Chime 24VDC 155 155 SM/DSM Wheelock CH-CF1-lS-24-CFW Chime 24 VDC 273 260 SM/DSM Wheelock CH-DF1-LS-24-VFR Chime 24 VDC 101 100 SM/DSM Wheelock CH-DF1-LSM-24-VFR Chime 24 VDC 145 120 SM/DSM Wheelock CH-DF1-MS-24-VFR Chime 24 VDC 155 155 SM/DSM Wheelock CH-DF1-IS-24-VFR Chime 24 VDC 273 260 SM/DSM Wheelock CH70-24 Chime 24VDC 22 22 SM/DSM Wheelock CH70-2415W Chime with Strobe 24VDC 105 85 SM/DSM Wheelock CH70-241575 Chime with Strobe 24VDC 127 102 SM/DSM Wheelock CH70-2430 Chime with Strobe 24VDC 153 122 SM/DSM Wheelock CH70-2475 Chime with Strobe 24VDC 239 187 SM/DSM Wheelock CH70-24MCW-FRIW Multi-Candela Chime with Strobe 24VDC 392 max * 257 max * SM/DSM Wheelock CH90-24 Chime 24VDC 22 22 SM/DSM Wheelock CH90-24MCC-FW Multi-Candela Chime with Strobe 24VDC 422 max 314 max SM/DSM** Wheelock CH90-2475C Chime with Strobe 24VDC 259 251 SM/DSM Wheelock CH90-24100C Chime with Strobe 24VDC 318 314 SM/DSM Wheelock DSM-12/24 Dual Synchronization Module 12V 0D0' 38/82 20/50 N/A Wheelock E70 Speaker N/A * * N/A Wheelock E70-2415W Speaker with Strobe 24VDC** 83** 6**3 SM/DSM** 12 Ansu! Device Compatibility Document Document 50054 Rev:J ECN 05-706 04/05/05 0 I Detector - Base - J RP-1001,RP-1002 MMX-2 Model Model AUTOPULSE 442R/D, FZM-1 PCR-1 00 70-201000-001 Fenwal CPD-7021 70-201000-002 30 40 70-201000-003 70-201000-005 70-201000-001 Fenwal PSD-7125 70-201000-002 20 24 70-201000-003 70-201000-005 70-201000-001 Fenwal PSD-7126 70-201000-002 20 24 70-201000-003 70-201000-005 Fenwal PSD-7129 70-201000-000 1 1 HS-22D 25 HS-2-RB 1 Hochiki SIH-24F YBA-M22 30 25 HSB-220 25 HSB-224 N/A HS-220 25 HS-2-RB 1 Hochiki SLK-24F YBA-M22 30* 25 HSB-220 25 HSB-224 N/A HS-22D 25 HS-2-RB 1 Hochiki SLK-24FH YBA-M22 30* 25 HSB-220 25 HSB-224 N/A HS4-224 Hochiki SIJ-24 ANSUL#427599 10 12 ANSUL#427595 HS6-224 ANSUL#427598 HS4-224 Hochiki SLR-24 ANSUL#427599 12 15 ANSUL#427596 HS6-224 ANSUL#427598 HS4-224 Hochiki SLR-24H ANSUL#427599 12 15 ANSUL#427597 HS6-224 ANSUL#427598 Notifier CP-651 B401 / B61OLP / B616LP 15/1511 20/20/1 Notifier SD-651 B401 / B61OLP / B616LP 15/15/1 20/20/1 Simplex 2098-9201 HB-54 N/A 20 Simplex 2098-9202 HB-54 N/A 20 Simplex 2098-9576 HB-54 N/A 20 System Sensor 2W-B N/A 20 20 System Sensor 2WT-B N/A 20 20 System Sensor DHI OOP N/A 15 20 System Sensor DHIOOLP N/A 15 20 System Sensor IIOOID N/A 20 24 System Sensor 1400 N/A 20 24 System Sensor 1451 8401 / B401 / B406 15/15/1 20/20/1 System Sensor 1451 DH DH-400 15 20 System Sensor 1800 N/A N/A 24 System Sensor 1851B BIO1B N/A 20 System Sensor 1851B 8107B N/A 1 System Sensor 1851 DH DH1851DC 15 20 System Sensor 2100/D/S N/A 20 24 System Sensor 2100T/D/S N/A 20 24 System Sensor 2151 B401/B110LP/B116LP 20/20/1 20/20/1 System Sensor 2400 N/A 15 20 System Sensor 2400A1T N/A 1 1 System Sensor 2400AT N/A [ 1 1 18 Ansul Device Compatibility Document Document 50054 Rev:J ECN 05-706 04/05/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE *LISTING No. 7165-0595:111 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Ansul Fire Protection, One Stanton Street, Marinette, WI 54143-2542 Contact: *Jim Engman (715) 735-7411 Fax (715) 732-3634 DESIGN: Model AUTOPULSE 442D (preaction/deluge) and AUTOPULSE 442R (release). Inherently power- limited; non-coded; local, auxiliary, remote station (protected premises), proprietary (protected premises) and central station service; sprinkler supervisory and releasing device service. Refer to listee's data sheet for system detailed product description and operational considerations. System components: 4XTM Transmitter Module 4XZM Relay Module 4XLM Interface Module 4XMM Meter Module DP-4X Dress Panel 4XARB-1 Main Board 4XARB-2 Main Boards 4XARB-4 Main Board OPTIONS: Refer to listee's data sheet for other required/optional accessories. When required, accessories shall be listed by CSFM. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. \PPROVAL: Listed as fire alarm control panels for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. XLF: 7165-0028:161 Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy 0 Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0410:107 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Hochiki America, 7051 Village Dr., Suite 100, Buena Park, CA 90621 Contact: Bob Misiuk (714) 670-3251 Fax (714) 690-7890 DESIGN: Models SLG-12, SLG-24, SLG-24FH, SLG-24F, SLK-12, SLK-24F, SLK-24FH, SLK- 24FB, SLK-24FL, SLK-24FLB, SLK-835, SLK-835H, SLR-835, SLR-835W, SLR-835B- 2, SLR-835B-4, SLR-835B-2W, SLR-835B-4W, SLR-24, SLR-24H, SLR-24V, *SLR 24VN, SLR-835H, SLR-835HW, SLR-8356H-2, SLR-835BH-2W, SLR-835BH-4, SLR- 835131-1-4W photoelectric type smoke detectors. Unit with suffix -H or -FH employs a supplemental heat sensor. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING 12 VDC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. io ARKING Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units when used in conjunction with listee's listed bases (CSFM Listing No. 7300- 0410:132). Models with supplemental heat sensor are not approved for use in lieu of required heat detectors. NOTE: Formerly 7257-0410:107 Rev. 2-14-2003 IPI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;fr recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy 0 Program Manager ISTING No. CATEGORY: LISTEE: DESIGN: I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0410:132 Page 1 of 2 Misc. Devices/Control Unit Accessories Hochiki America, *7051 Village Dr., Suite 100, Buena Park, CA 90621-2268 Contact: Bob Misiuk (714) 670-3251 Fax (714) 690-7890 Detector bases (2 and 4-wire). Unit is intended for use with a separately listed compatible detector head. Refer to listee's data sheet for detailed product description and operational considerations. Models listed below. HA-4W HA-4W1 HA-4WX HA-2 HA-SL HA-SR HA-SLR HA-RA2 HA-NRA2 HA-L1 2R HA-213 HA-22R HA-L2 HA-L2A HA-L2R HA-1_22 HA-1_22A HA-1_22F HA-L22R HA-1_225 HA-LA2 HA-LRA HA-LRA2 HA-LNA2 HA-LNRA2 HS-2 HS-2L HS-2D HS-21 HS-21L HS-21D HS-22 HS-22L HS-22D HS-100 HS-200D HS-220 HS-220L HS-220D HS-221 HS-221L HS-221 D HS-221X HS-221 XL HS-221 XD HS-224 HS-224L HS-2240 HS-225 HS-225L HS-225D HS-2RB HS-21RB HS-220RB HS-221 RB HS-224RB HS-2RB4 HSB-2 HSB-2N HSB-12-1 HSB-12-1N HSB-12.-4 HS13-124N HSB-21 HSB-21N HSB-1 00 HSB-200 HSB-200N HSB-220 HSB-220N HSB-221 HSB-221 N HSB-2215 HSB-224 HSB-224N HSB-225 HSB-225N HSC-413 HSC-21L HSC-220L HSC-220R HSC-221L HSC-221R HSC-224RA HSC-224L HSC-224R HSC-225L HSB-DCP-6 HSB-NSA-6 YBA-M2 YBA-M21 YBA-M22 YBA-M220 YBA-M221 YBA-M224 YBA-M225 YBA-M100 YBA-MAP YBA-R3 YBA-RLJ4 YBA-RL/4-1 YBA-RLI4-2 YBA-RL/4-RA YBC-RLI12 YBC-RLI12-1 YBC-RLI12-2 YBC-RLI12-4 YBC-RLI4-RA YBC-RL/2NC YBC-RLJ2NBE YBJ-RL/2ND YBN-R/2NA YBN-NSA-4 NS4-100 NS4-220 NS4-221 NS4-224 NS6-100 NS6-220 NS6-221 NS6-224 Models may or may not come with suffix -W. corrected. 11 -06-2001 Listing No. 7300-0410:132 Page 2 of 2 I NSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING:Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as bases for use with listee's separately listed compatible smoke and heat detectors. Refer to heat or smoke detector listings for compatibility. Models HA-2R, HA-SLR, HA-LRA2 and HSC Series WI suffix R are also suitable for releasing device service. Model YBA-R3 is intended for use with thermostat detector only. NOTE: Formerly 7300-0410:100, 106, 115, 124, 125, 126, 130, 131 & 133 I Corrected 11-06-2001 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1408:107 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Signal Communications Corp., 4 Wheeling Avenue, Woburn, MA 01801 Contact: Nadim Farhat (781) 933-0998 Fax (781) 933-5019 DESIGN: Models SG-32AX, SG-32B, SG-32PS, SG-32S, *sG32Cx SG-33B, SG-33S, SG-33AX, SG-34B, SG-34S, SG-34AX, and SG-34PS, *5G365 *sG36Ax *5G36CX noncoded manual pull stations followed by H (hex lock) or K (key lock), followed by suffix 1 (push bar) or 2 (no push bar) and *5GB325 indoor back box. Models SG-32PS and SG-33P5 do not have suffix -1 or -2. Suitable for outdoor use when installed with Model SGB-32C back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. ARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Rev. 12-16-2005 t' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2006 Listing Expires June 30, 2007 W horized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE SLISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc. 273 Branchport Ave. Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric It, character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. 0 *Rev. 06-13-06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test result s and/or other data but does not make an independent verification of any claims. This listing is not an endor s e m e n t o r recommendation of the item listed. This listing should not be used to verify correct operational requirements or installa t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager ANSUL® DETECTION AND AUTOPULSE®442R CONTROL AGENT EQUIPMENT RELEASING 0 DATA SHEET CONTROL UNIT FEATURES Complies with: NFPA 71 Central Station Signaling Systems NFPA 72 Local, Auxiliary, Remote Station, and Proprietary Protective Signaling Systems NFPA 12 CO2 (High pressure only) Extinguishing Systems NFPA 12A Halon 1301 Extinguishing Systems NFPA 128 Halon 1211 Extinguishing Systems NFPA 2001 Clean Agent Fire Extinguishing Systems Microprocessor-Controlled Power-limited on All Circuits Except Municipal Box output Alarm And Trouble Resound 2 Initiating Circuits (Style B/D) Abort Switch Input Circuit (Style BID) Manual Release Input Circuit (Style B/D) Supervisory Input Option (Style B) 2 Indicating Appliance Circuits (Style Y/Z) 2 Release Circuits (Style Y) Cross-zone Option Delay Timer: 0, 10, 20, or 30 Seconds. Special Abort Options For IRI, New York City, And Other Local Jurisdictions Distinct Audible Indications For: 1 Zone in Alarm; 2 Zones in Alarm; Release General Alarm And Trouble Relays Optional Module For 4 Zone/Function Relays (4XZM) Optional Transmitter Module (4XTM) Optional Volt/Amp Meter Module (4XMM) * Optional Supervised Remote Annunciator (RZA-4X). Requires LED Interface Module (4XLM) Optional digital communicator (NOTIFIRE 911) Disable/Enable Controls Per Initiating Zone Battery/Earth Fault Supervision Last Event Recall Feature to Identity Intermittent Trouble Conditions RMS Regulated 24 VDC Output Power, 2.25 Amperes 7.0 AH to 15 AH Battery Options, Up To 90 Hours Standby 230 VAC, 50 Hz International Option 4-Wire Detector Resettable Power Output Non-Resettable Regulated 24 VDC Power Output Extensive Transient Protection Watchdog Timer to Supervise Microprocessor Output Circuits Protected Against False Activations By 2-Step Command Sequence Slide-In Labels For Zone Identification Steel Cabinet 14 in. (36 cm) Wide x 16 in. (41 cm) High x 5 in. (13 cm) Deep Dead-Front Dress Panel Option Trim Ring For Flush Mount Between 16 in. (41 cm) Center Studs (TR-4XR) DESCRIPTION The AUTOPULSE 442R is a cost effective detection and releasing control unit utilizing conventional wiring methods for protection of a single hazard area. Cross zone detection with programmable time delays and abort capability, immediate manual actuation, two alarm circuits, two release circuits, alarm and trouble relays, and auxiliary 24 VDC make this a very flexible control unit capable of releasing INERGEN, Carbon Dioxide, and Dry Chemical fire suppression systems. Circuits INPUT CIRCUITS: Detector Zone 1 (Style BID) Detector Zone 2(Style B/D) Abort (Style B/D) Manual Release (Style B/D) Supervisory (Style B) OUTPUT CIRCUITS: Indicating Circuit 1 (One Zone In Alarm) Indicating Circuit 2 (Pulse With 2 Zones In Alarm And Sound Steady On Release) Releasing Circuit I Releasing Circuit 2 FRONT PANEL CONTROL SWITCHES: Switch I Tone Silence Switch 2 Alarm Silence Switch 3 Alarm Activate d Switch 4 System Reset ~onal Boards Te Ansul AUTOPULSE 442R Control Unit has mounting slots for two option boards. Any two of the three option modules may be installed: TRANSMITTER MODULE (4XTM): The Transmitter option provides a supervised output for local energy municipal box trans- mitter (for NFPA-72 Auxiliary Protective Signaling System) and alarm and trouble reverse polarity (for NFPA-72 Remote Station Protective Signaling System). Also included is a DISABLE switch and disable trouble LED. A jumper option allows the reverse polarity circuit to open with a System Trouble condition if no alarm condition exists. LED INTERFACE MODULE (4XLM): The module supports the RZA-0 Remote Annunciator module. The module mounts to the main board occupying one of the two option connectors. LED wiring is supervised for opens. Faults will activate System Trouble condition. ZONE RELAY MODULE (4XZM): The Zone Relay module provides Form-C general alarm and trouble contacts and the following Form-C relays: One detector in alarm Two detectors in alarm Releasing Circuit 1 Activated Releasing Circuit 2 Activated *'IOTE: Relays can be silenceable/non- silenceable by jumper option. TE ANNUNCIATOR (RZA-4X): The Remote Annunciator mounts on a stan- dard single-gang box and provides the fol- lowing: System Trouble LED (yellow) Local Piezo Sounder Silence Switch (for local sounder) Indicating Circuit 1 LED (red) Indicating Circuit 2 LED (red) Releasing Circuit 1 LED (red) Releasing Circuit 2 LED (red) NOTE: The Remote Annunciator requires the use of an LED Interface module Optional Meters VOLTAGE AND CURRENT METER (4XMM): The 4XMM provides a voltmeter to measure the voltage across the batteries and an ammeter to measure the charging current to the batteries. The meters are provided as an assembly that mounts to the lower left-hand comer of the cabinet. SPECIFICATIONS AC Power 120 VAC, 60 Hz, 1.2 amps Wire size: 14 AWG with 600 V insulation Initiating Circuits • Power-limited circuitry Operation: Style B (Class B)/Style D "lass A) voltage: 24 VDC (ripple = 10 mV *t by -peak) • Alarm current: 15 mA minimum Short circuit current: 40 mA maximum Maximum detector current in standby: 2 milliamps (peak) per zone Maximum loop resistance = 200 ohms End-of-line resistor: 4.7 K, 1/2 watt Detector loop current is sufficient to ensure operation of one alarmed detector per zone Supervisory current: 5 mA. Indicating/Releasing Circuits Power-limited circuitry Maximum voltage drop due to wiring: 2 VDC Voltage: 24 VDC RMS regulated (not filtered) Total current to all external devices: 2.25 amps max Maximum signaling current per circuit: 1.5 amps End-of-Line Resistor = 4.7 K, 1/2 watt Alarm and Trouble Relays Dry Form-C contacts rated for: 2.0 amps @ 30 VDC (resistive) 0.5 amps @ 30 VAC (resistive) Digital Communicator NOTI.FlRE 911: For Central Station service: (NFPA 71 Central Station Protective Signaling System) or Remote Station Service (NFPA 72 Remote Station Protective Signaling System) Transmitter Module (4XTM) For Local Energy Municipal Box service (NFPA-72 Auxiliary Protective Signaling System): Supervisory current: 5.0 mA Trip current: 0.35 amps. (Subtracted from Indicating Appliance power) Coil Voltage: 3.65 VDC Coil resistance: 14.6 ohms Total wire resistance between panel and trip coil = 3 ohms For Remote Station service (NFPA-72 Remote Station Protective Signaling System): Maximum current allowed for both circuits shall not exceed 10 mA per circuit. Reverse polarity output voltage = 24 VDC. Zone Relay Module (4XZM): Dry, Form-C contacts rated for: 2.0 amps @ 30 VDC (resistive) 0.5 amps @ 30 VAC (resistive) Four-wire Smoke Detector Power Output Terminals: Up to 200 mA of current is available for 4- wire smoke detectors. RMS Regulated 24 VDC Power Output Terminals: Total DC current available for powering external devices is 0.5 amp (subtracted from indicating appliance power dedicated to all output circuits). Non-resettable 24 VDC Power Output Terminals: Total DC current available from this output is up to 200 mA (subtracted from four-wire smoke power). Field Program Selections: 6-position dip switch to select: Cross Zone Operation Supervisory Input Delay Time: 0, 10, 20, or 30 seconds - Abort Mode Cabinet Dimensions Door: 16.125 in. High x 14.625 in. Wide (40.9 cm x 37.2 cm) Backbox: 16.0 in. High x 14.5 in. Wide x 4.75 in. Deep (40.6 cm x 36.8 cm x 12.1 cm) Cabinet: 5.375 in. Deep (13.7 cm) LISTINGS AND APPROVALS UL ...........................S4935 (Listed for Manual and Automatic Fire Alarm Service. Suitable as Releasing Service Control System) ULC ..................... .... CS412 FMRC ......................Approved CSFM ......................Approved MEA .......................Approved (City of New York) European Community Conformity ..................Approved (220VAC Model) ORDERING INFORMATION Approximate Shipping Weight Part No. Description !b th9 417696 AUTOPULSE 442R, 25 (11.3) Agent Releasing Control Unit, Red, 120 VAC 417697 AUTOPULSE 4.42R, 25 (11.3) Agent Releasing Control Unit, Red, 230 VAC 417692 Battery Pack, 7 AH, 15 (6.8) 24 VDC 417693 Battery Pack, 12 AH, 22 (9.9) 24 VDC 417475 TR-4XR, Trim Ring 2 (0.9) for Semi-Flush Mounting, Red 417472 4XMM, Ammeter- 2 (0.9) Voltmeter Module 417881 4XZM, Zone Relay 2 (0.9) Module 417882 4XLM, LED Interface 2 (0.9) Module 417883 RZA4X, Remote 2 (0.9) Annunciator 417470 4XTM, Plug In 2 (0.9) Transmitter Module, Municipal Box and Remote Station Connection 417890 Dress Plate, 2 (0.9) Full Length Dead Front (ULC and FM) ANsuL. AUTOPULSE and INERGEN are registered trademarks. ANSUL INCORPORATED, ONE STANTON STREET, MARINETrE, WI 54143-2542 715-7357411 Form No. F-54124-1 ©1998 Ansul Incorporated Lithe in U.S.A. Ordering Information Part No. Description 417881 4XZM Zone Relay Module ANSUL and AUTOPULSE are registered trademarks. Shipping Weight lb. (kg) 0.5 (0.23) ANSUL Detection and Control Components ZVI 4XZM Zone Relay Module Description The 4XZM Zone Relay Module is an optional module with zone/function relays for use with the AUTOPULSE® 442R and AUTOPULSE 442D control systems. Listings for this module are under the control unit. The Zone Relay module provides Form-C general alarm and trouble contacts, plus four Form-C relays that activate with each of the four output circuits. These relays can be silenced/non-silenced by jumper option. Technical Information Dry, Form-C contacts rated for: 2.0 amps @ 30 VDC (resistive) 0.5 amps @ 30 VAC (resistive) - I NO - 2 NC RELAY #1 —3 C —4 NO - 5 NC RELAY#2 —6 C —7 NO - 8 NO RELAY#3 —9 C J - 10 NO - 11 NC RELAY #4 - 12 C - 13 NO - 14 NC ALARM - 15 C - 16 NO - 17 NC TROUBLE - 18 C RELAY #1 THROUGH #4 WILL ACTIVATE WITH OUTPUT #1 THROUGH #4 AND REMAIN LATCHED UNLESS JUMPER *LATCH" IS CUT CUT JUMPER FOR NON. I LATCHING (SILENCEABLE) USE DISABLE SWITCH TO RELAY OPERATION DISCONNECT THE RELAYS 0 3-2 ANSUL INCORPORATED, ONE STANTON STREET. MARINETTE. WI 54143-2542 715-735-7411 Form No. F-9579 (A1995 Ansul Incorporated Litho in U.S.A. 1 7/8 IN. (47 mm) -4 .- 5/16 IN. (8 mm) I 3 15/16 IN. (100 mm) 004632 119/16 IN. 9/16 IN. (49 mm) P (14 mm) 5 7/8 IN. (149 mm) 0 I. I ll04631 ANSUL® Detection and Control Components SLR-24 Photoelectric Smoke Detector Features Low profile, 1.8 in. (46 mm) high —with base 2 or 4 wire base compatibility, relay bases available Highly stable operation, RFlTransient protection Low standby current, 45pA at 24 VDC Two built-in power/sensitivity supervision/alarm LEDs Non-directional smoke chamber Vandal resistant security locking feature Built-in magnetic go/no go detector test feature Removable smoke labyrinth for cleaning or replacement Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7, Inspection, Testing and Maintenance Compatible with SIJ-24 ionization detectors Backwards compatible with SLK and SIH detectors Applications .The SLR-24 Photoelectric Smoke Detectors are intended for use in commercial, industrial, and institutional buildings. The detectors are placed primarily in clean, indoor environments where early warning fire detection is required. The detectors are used in combination with an Ansul AUTOPULSE® Control System and an Ansul fire suppres- sion system for automatic detection, alarm, equipment con- trol, and fire suppression system release capabilities. Description The SLR-24 photoelectric smoke detector utilizes two bicolor LEDs for indication of status. In a normal standby condition the LEDs flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LEDs will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the status LEDs will latch on Red. The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. In a normal standby condition, the receiving element receives no light from the pulsing LED light source. In the event of a fire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Signals are processed and compared to a reference level, and when two consecutive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm .signal. The status LEDs light continuously during the alarm period. DIMENSIONS - NS6-224 BASE 1 7/8 IN. 7/16 IN. (I (47 mm) 11 mm) 57181N, (149 mm) Ii) 1 004631, TO 3 OR 4 IN. OCTAGON OUTLET BOX DIMENSIONS - HSC-224RA BASE 2 1/2 IN. 11/8 IN (63 mm) 104 IN. SQUARE OR (29 mm) 4 IN. OCTAGON OUTLET BOX 57/8 (149 mm) J ) - 633 3.1431 3-18 104 IN. SQUARE OR 4 IN. OCTAGON OUTLET BOX - -. \\f,; _G4630 DIMENSIONS - NS4-224 BASE 103 IN. OCTAGON OUTLET BOX \\ ....-.- 004625 DIMENSIONS - HSB-21 BASE TO 4 IN SQUARE OUTLET BOX Technical Information Detector Base/Control Unit Compatibility etector AUTOPULSE 0ase FOUR 442R, IQ-301, IQ-396X —part No.) 442D MMX-2 NS6-224 (427598) No Yes Yes HSB-21 (417457) Yes No No NS4-224 (427599) No Yes Yes HSC-224RA (416849) 2 wire only* No No *Note: 2-wire Single Zone or Cross Zone only; not for use on Counting Zone Circuit Rated Voltage: .......................17.7 to 33.0 VDC Working Voltage: ....................... 15 to 33.0 VDC Surge Current ...................... 160pA@ 24 VDC Normal Current ......................45pA @ 24 VDC Alarm Current .............150 mA maximum @ 24 VDC Ambient Temperature' ....+32 °F to +120 °F (0 °C to 49 °C) Humidity .........................95% R.H. maximum Color ...................................Bone White Sensitivity Test Feature: ...... Automatic sensitivity window verification test WIRING DIAGRAM -TWO WIRE OPERATION RESISTOR SHOWN IS FOR EXAMPLE ONLY. NOT ALL ANNUNCIATORS HAVE IN-LINE RESISTANCE. NS4 BASE NS6 BASE EOL RESISTOR J NOTE: WIRING TO TERMINALS 7 AUTO- FOR THE NS4 -v'--t,--,-I{,-4. )) AND NSB ARE ,..4., .LSE(—) NTROL f \/J IDENTICAL. NEL ANNUNCIATION VICE MUST BE 430 OHM CURRENT LIMITED TO 20 mA @24 VDC RESISTOR MAXIMUM. NOT CURRENT LIMITING CURRENT COULD RESULT IN DAMAGE TO IN4003 DIODE MUST BE THE DETECTOR OR INSTALLED IN SERIES CAUSE A NO ALARM CONDITION. --- WITH THE 430 OHM RESISTOR WHEN BASE IS USED TO OPERATE REMOTE LED. 004627 WIRING DIAGRAM - HSB-21 AND HSC-224RA* STANDARD BASES, STYLE B EOL RESISTOR (—)------I J \— / ') N.— I - ___. .L. 'REMOTE T.2._ REMOTE LEO 504628 SYSTEM COMMON (DC RETURN) Do not wire HSC-224RA to remote LED an shown. Annunciation for the relay base (HSC-224RA) must be wired to the relay contacts using external power. Mounting Guidelines The detector bases are designed for surface mounting. The detector head can be inserted or removed from the base without disrupting the wiring connections. The following bases are compatible with the SLR-24 Photoelectric Detector: Base Type of Mounting Box HSB-.21 4 in. Octagon, 4 in. Square NS4-224 3 in. Octagon NS6-224 4 in. Octagon, 4 in. Square HSC-224RA 4 in. Octagon, 4 in. Square HSC-224RA RELAY CONTACT TERMINAL STRIP ORANGE WIRE C 1 VIOLET WIRE NC 2 YELLOW WIRE NO 3 GRAY WIRE NO 4 GREEN WIRE NC 5 BLUE WIRE C ® 6) TB1 CONNECTIONS --------------------------- 004629 Listings and Approvals* UL..........................................S1383 ULC ........................................CS463 California State Fire Marshal (CSFM).......7272-0410:107 Factory Mutual Research Corporation (FMRC)... 105A1 .AY MEA......................................284-91-E Listings and Approvals are under HOCHIKI AMERICA CORPORATION Ordering Information Shipping Weight Part No. Description lb. (kg) 427596 SLR-24 Photoelectric Detector 1 (0.4) 427598 NS6-224 Base 0.5 (0.2) 427599 NS4-224 Base 0.5 (0.2) 417457 HSB-21 Base 0.5 (0.2) 416849 HSC-224RA Relay Base 0.5 (0.2) 415730 Test Magnet 0.5 (0.2) 415802 TSE-A100 Smoke Generator 5.0 (2.3) ANSUL and AUTOPULSE are registered trademarks. 9 ANSIJL INCORPORATED, ONE STANTON STREET. MARINETTE, VVt 54143-2542 715-735-7411 Form No. F.200084 02001 Ansul Incorporated Litho in U.S.A. ANSUL® Detection and Control Components Electric Manual Pull Station Features UL Listed/FM Approved Approved for ADA Dual action Die-cast metal construction Terminal block Optional auxiliary contacts Flush mounts on single gang box Surface mount back box available Weatherproof back box available High-gloss red enamel finish Customized labels Keyed to match AUTOPULSE control units STANDARD PULL STATION 7/8 IN. bin 4 11/16 IN. IJ (119MM) 0D46?2 31141N. I (83 mm) I Applications The Electric Manual Pull Station is a cost-effective, feature- packed, non-coded manual fire alarm pull station. It was designed to meet multiple applications with the installer and WEATHERPROOF PULL STATION end-user in mind. The pull station provides the AUTOPULSE 442R, AUTOPULSE 442D, AUTOPULSE IQ-301 and AUTOPULSE IQ-396X with an alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the pull station simple to install, maintain, and operate. Description The Electric Manual Pull Station is a high quality, die-cast metal dual action fire alarm pull station available with a SPST, DPST or DPDT switch, with terminal strip connec- tions. The contacts are rated for 1 Amp at 30 VDC. Gold plat- ing on the contacts avoid the risk of corrosion. All models in the series have been tested by UL for compliance to the lat- est requirements of the American with Disabilities Act (ADA). The Electric Manual Pull Station is operated by pushing in the top bar and pulling the handle on the front of the station as far down as it will go; at which point the handle locks into place and is easily visible from up to 50 feet. Opening the station with the key, placing the handle in the normal upright position and re-locking the station resets the pull station. The addressable ready pull station comes with a bracket on the back for securing the FMM-101 Mini Monitor Module. The terminal block provides clamping plates for easy con- nection to the SLC loop and N. 0. switch contacts. An end- of-line resistor for the AUTOPULSE 10-301 and I AUTOPULSE 10-396X is factory installed across the switch contacts. 06 3 1/4 IN- (83 mm) 4 11/16 IN. (119 mm) 3 1/4 IN. (83 mm) flO4648 3-1-01 3-32 TO AUTOPULSE TO NEXT CONTROL UNIT DEVICE EOLR 004924 WIRING - DPST PULL STATION I-----1 TO AUTOPULSE CONTROL UNIT WIRING - EXPLOSION PROOF PULL STATION F©©II III©1 '1TI IYH _ TOAUTOPULSE TO NEXT EOLR CONTROL UNIT DEVICE 004930 WIRING —ADDRESSABLE READY PULL STATION FMM-1O1 BLACK YELLOW EOLR TO NEXT 4929 DEVICE WIRING - SPST PULL STATION TECHNICAL INFORMATION 4ornventional/Addressable Read ch Ratings .......................1 A @ 30 VDC 1 A@ 120 VAC Switch Type: .......................... SPST or DPST Terminal Size: ......................... Up to 14 AWG Color ...............Red with raised white letters, white PUSH/PULL HANDLES with raised red letters Weather Proof with Weather Proof Back Box . . . NEMA 3R Explosion-proof Switch Ratings: ...................... 1 A @ 30 VDC, 10A@ 120 VAC Switch Type... .............................. DPDT Terminal Size: ........................ Up to 14 AWG Humidity: .............90% Relative at 100 °F (37.7 °F) Explosion Hazard Classifications: . Class I Groups B, C, 0; Class It Groups E, F, G; Class Ill Weatherproof Classifications: ........... NEMA Type 4X Other Classifications ................UL Marine Listing Conduit Fittings: ................................. 2 Conduit Fitting Size: ..................3/4 in. - 14 NPT Color ..............Red with raised white letters, white PUSH/PULL handles with raised red letters LISTINGS AND APPROVALS* .....................................E192508 C.........................................isted Factory Mutual Research Corporation (FMRC) .....Listed California State Fire Marshal (CSFM) .....7150-1408:107 MEA....................................382-94-E ORDERING INFORMATION Shipping Part Weight No. Description lb. Qsgj 428655 Manual Pull Station, SPST 1 (0.45) 428656 Manual Pull Station, DPST 1 (0.45) 428657 Explosion Proof Manual Pull Station 1 (0.45) 428658 Manual Pull Station, 1 (0.45) Addressable Ready 428659 Weatherproof Back Box 1 (0.45) 428660 Surface Back Box 1 (0.45) 428661 Break Rod 1 (0.45) 418336 Key 1 (0.45) 428654 Label Packet 1 (0.45) Listings and Approvals are under Signal Communications Corporation ANSUL and AUTOPULSE are registered trademarks. TO AUTOPULSE CONTROL UNIT - 004931 ANSUL INCORPORATED. ONE STANTON STREET, MARINErrE. WI 54143-2542 715-735-7411 Form No, F-2001032 ©2001 Ansut Incorporated Litho in U.S.A. n KEY-OPERATED CONTROL UNIT LOCK-OUT SWITCH RELEASE CIRCUIT - TERMINALS*N — -- - N 1 I POLARITY IS SHOWN I IN ALARM I CONDITION 24 VDC 4 11/16 IN. (119mm) 0 NORMAL O (00 ANSUL FIRE SUPPRESSION SYSTEM ABORT 0 FLUSH-MOUNT 2 3/4 IN. — - (70 mm) SURFACE-MOUNT S lip 1KI 4 5/8 IN. (117 mm) ANSUL® Detection and Control Components isuu.uu...ml.lIIuIu..u.u.uuu ui . uailuuu• .0 mu ii.... i I.. i..• SNUL AU Key Maintenance Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Key Maintenance Switch is used to interrupt the release circuit signal to the fire suppression system. It is key-operat- ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, located on the switch plate, will light when the switch is in the lock-out" mode to serve as a reminder that the release cir- cuit has been disconnected. Description The Key Maintenance Switch assembly consists of a key- operated switch, 24 VDC indicator lamp, normally-open con- tact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assem- blies include a double-gang weather-proof box and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed when installed in the surface-mount box (with gasket) that is provided with the surface-mount assembly. TYPICAL WIRING DIAGRAM 24 VDC INDICATOR LAMP SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. Ordering Information Part No. Description Shipping Weight lb. (kg) 76498 Maintenance Switch, Surface-Mount 2.0 (0.9) 76499 Maintenance Switch, Flush-Mount 2.0 (0.9) 76485 Extra Contact Block, N.C. 0.25 (0.11) 76486 Extra Contact Block, N.O. 0.25 (0.11) 78179 Spare Key 0.25 (0.11) ANSUL and AUTOPULSE are registered trademarks. MOUNTING DIMENSIONS 3-33 ANSUL INCORPORATED. ONE STANTON STREET. MARINETTE. WI 54143-2542 715-735-7411 Form No. F-95110 91995 Ansul Incorporated LiIho in U.S.A. I ANSUL® Detection and Control Components Abort Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Abort Switch is used to momentarily interrupt the release circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- sion system will not release. (Note: When the control unit is programmed for IRI compliance, the abort will not be effec- tive after pre-discharge.) When the pushbutton is released, the release circuit is activated (unless the control unit has been reset to the non-alarm condition). Description The Abort Switch assembly consists of a momentary- contact pushbutton switch, normally-open contact block, Listings and Approvals The switch is UL listed (S3623) when installed in the surface- mount box (with gasket) that is provided with the surface- mount assembly. MOUNTING DIMENSIONS TYPICAL WIRING DIAGRAMS ABORT SWITCH (SERIES) 1 EOL RESISTOR L j CONTROL. UNIT - - - ABORT CIRCUIT N.C. ABORT I TERMINALS SWITCH .- -- - - ABORT SWITCH (PARALLEL) EOL RESISTOR - I ( I fOu N.C. ABORT CONTROL UNIT ABORT CIRCUIT SWITCH SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. Ordering Information Shipping Weight Part No. Description lb. (kg) 76494 Abort Switch, Surface-Mount 1.0 (0.45) 76495 Abort Switch, Flush-Mount 1.0 (0.45) 76485 Extra Contact Block, N.C. 0.25 (0.11) 76486 Extra Contact Block, N.O. 0.25 (0.11) ANSUL and AUTOPULSE are registered trademarks. • normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assemblies include a single-gang weather-proof box with three 1/2 in. I.P.S. threaded conduit outlets and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC © 1.1 amp make/break or amp continuous carry. 2 718 IN. (73 mm) II II ANSUL II SYSTEM ABORT FIRE SUPPRESSION 4 5/8 IN. 0 (117 mm) PUSH AND HOL D [10 SURFACE-MOUNT 2518 IN FLUSH-MOUNT 2 3/8 IN. (60 mm) 9L 3-34 ANSUL INCORPORATED ONE STANTON STREET. MARINE1TE, Wi 54143-2542 715-735.7411 Form No. F-95111 ®1995 Ansul Incorporated Litho in U.S.A. whe-elock ADA • MEA . S Helping People Take Actions' SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or Wheelock's patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/11 0cd, or the high intensity MCWH strobe with field selectable 135/185cd. I Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-12/24-8CP and PS-12/24-8MP Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. 0 For Weatherproof Series AS, See Datasheet S9004 Copyright 2004 Wheelock Inc. All rights reserved. SERIES AS SERIES AH Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information. ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30175/110cd or 135/185cd (Multi-Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15130175/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage Range' using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY AMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 'eneral Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of Ito 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Input voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela lcdl AS-24MCW 24 16.0-33.0 15/30/75/110 As-24MccH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15(7500 Axis) AS-121575W 12 8.0-17.5 15(75onA4s) AS-24M00 24 16.0-33.0 15130/75/95 AS-24MC WI 24 16.0-33.0 135/185 AS\Mx.2475W 24 16.0-33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL464@lOft. Anechoic dBA @lOft. Continuous Horn High 91 99 Medium 88 83 95 go Code3Hom Low High 87 99 Medium 84 95 Low 79 90 Table 3. Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd llocdl 135cd 185cd l5cd 30ed 75cd 95cd 115cd 177cd 24 vdc 0.062 0.100 0.080 0.102 0.150 0.1941 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 High (99) dBA ULmax* 0.080 0.121 0.088 0.125 0.2000.267j0.355 I _0.480 0.095 0.138 0.221 0.285 0.355 0.480 dBA 24 vdc 0.033 0.080 1 0.060 1.084 1 0.132 1 0.173 1 0.230 1 0.305 1 0.066 1 0.092 0.145 0.186 0.230 1 0.305 Med (95) UL max* 0.043 0.107 1 0.074 1 0.110 0.190 1 0.253 0.340 1 0.465 1 0.080 1 0.122 0.2011 0.269 0.340 0.465 Low 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 (90) dBA }- ULmax' 0.021 0.100 1 0.068 1 0.105 0.182 1 0.245 1 0.335 1 0.460 1 0.074 1 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS Current within the listed voltage range (16- 33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. AH-1 2 AS-121575W High 99 dBA 12 &Jc 0.163 0.260 UL max* 0.192 0.320 Med (95) dBA 12 vdc 0.076 0 195 - UL max' _______ 0.108 - 0.275 Low (90) dBA 12 .dc 0.039 0.175 uLmax' 0.058 0.265 fl WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Seies AH, (P83641) Series AH-WP AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THE S E DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACI1Y SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams C SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT + APPLIANCE - OR EOLR OR FACP PRECEDING APPLIANCE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE - STROBE : "STROBE :: "Aud,ble AS EOLR Audible -Audible NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Audible NAC CIT. Strobe NAC CIT.. •_ Sync 1k1 EAS III 110+ I F Audible NAC Ci,1 I OSM #2 A Strobe NAC I AS AS I 1-1 Sync C rt-10 - Audible NAC Cii I I I Sync Strobe AS AS NAC Cir.[1 tJ___!j.N DSM Interconnecting wiring Shown. Maximum of twenty (20) SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS-12/24-8MP j RM OUTPUTS EOLR 4-CLASS 8 C OR OR AS Ron Li AS RSS Sereo PS-12124-RCP ,PS-t2i24-RMP For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12124-8CP and P84333 for PS-12/24-8MR Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in rdance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing Wcco: be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safely and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Encjineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with \ATheelock's SM, DSM Sync Modules or \Nheelock's PS-12/24-8CP or PS-12124-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information Order Sync w/SM, DSM 24 12 Wall Ceiling g Agency Approvals Model Code Strobe candela Non-Sync PS-12124-8cP or . VOC MountVOC OUfl Mounting Options' PS-12!24-8MP UL MEA CSFM FM BFP As-24Mcw-FR 9024 15/30175/110 X X X - X . A,6.D,E,FH,JN,O,R,X X X X X X AS24MCW-FW 9025 15/30175/110 X X x = X = X . X . X - - A,8.D,E.F,GH,J.N,0,RX A,B,D,E,FGH,J,NO,R.X X X X X X X As-24McvowFR 3468 135/185 X X X X * -24MCWH-FW 3469 135/185 X X X X X . X - X - . - A,B4O.E,F.GHJ,NO,R,X A,0,D,E,F.GH.J.N.O,R,X X X X X X * -241575W-FR 7405 15(75onA,os) X X X X X AS-121575W-FR 7410 15(75onA)os) X X X X ABDEFGHJNORX X X X X X AS-24MCC-FR 3161 15/30175/95 X X X - - X A,B.D.E.FGH.J,NO,R.X X X X X * AS-24MCC-FW 3162 15/30175/95 X X X . - X A.B4O.E,F,CH,J.N,O,R.X X X X X * As-24Mccl-1-Fw 3467 115/177 X X X X A,B,D,E.FGH,J,N.O,R.X X X X X * ASV\P-2475W-FR .9012 75 @ -31 T X X I X . X - I (see Data Sheet $9004) X X X X X AH-24-R 7892 . X X X .- X X A,B.D.E,FH,J,NO,R.x xx x X AH-24-W 7893 - .x1 X X . X X A,B.D,E,F.G1-tJ,N,O.R.X X XX:X AH12-R 7891 X X X X X ABDEFGI-IJNORX X X X X X AH-12-W 7894 X X . XL X X A.B,D,E,F,GH,J,N,O,R,XX X X X X AH24WPR 7416 XJ X X X K XIXX X AH12WPR j 7415 X X X X X K X X X PENDING Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. **For Weatherproof Series AS/AH specifications see data sheet S9004. ***Refer to Data Sheet S7000 for Mounting Options. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 -mail: Info@wheelockinc.com itt://wv.wheelockinc.com 3 YEAR WARRANTY Made in USA Member Distributed By: WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S810001/05 O jLern 1 CIan AgeMt System Components UL EX-4510 6-1-02 Page 1-1.1 REV. 3 CV-98 Valve/ Cylinder Shipping Assembly Description The cylinder is factory filled with INERGENe agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The equivalent length of the valve is equal to 20 ft. (6.1 m) of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300 Valve Brass Safety Relief Valve Brass Valve/Cylinder Assembly FMRC Approved UL Listed (EX-4510) Shipping Cap Steel I Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426620 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426594 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426150 435* (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426621 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426595 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426259 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) * NOTE: For Shanghai version, order Part No. 430935. Canadian IC Approved Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Enamel Paint 426712 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426713 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426714 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427551 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426715 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Epoxy CR Paint 426716 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426717 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426718 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427552 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426719 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE - RECORD TAG HEIGHT TO OUTLET CENTER 3 1/2 IN. PRESSURE (89 mm) GAUGE REFERENCE SAFETY J_ RELIEF VALVE ---&' / N / / \ / 002252 VALVE CV-98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. 0 NOTE: Use Flexible Discharge Bend, Part No. 427082, when attaching valve to supply pipe or manifold. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. L —I ANSUL INCORPORATED. ONE STANTON STREET. MARINETIE. Wi 54143-2542 715-735-7411 Form No. F-9877-3 ff12002 Ansul Incorporated Litho in U.S.A. System Components ANSUL® UL EX-4510 11-1-00 Page 1-3.6 S Booster Actuator do Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. 1 1/4-18 UNEF 11/8-18 UNEF 006037 0 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED. ONE STANTON STREET. MARINETrE, Wi 54143-2542 715-735-7411 Form No. F-2001066 @2001 Ansul Incorporated Litho in U.S.A. System Components ANSUL.® UL EX-4510 11-1-00 Page 1-3.7 In Cl&an Agent HF Electric Actuator Description Electrical actuation is accomplished by an HF electric Actuator, Part No. 73327, interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous, indoor environments where the ambient tem- perature range is between 0 °F to 130 °F (-18 °C to 54 °C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. An arming tool, Part No. 75433, is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical con- duit hookup. Technical Information Nominal Voltage: ..........12 VDC @ 0.57 amps Rated Voltage: Minimum: ...................12.0 VDC Maximum: ...................14.OVDC Thread SizeIType ........1/2 in. straight female for electrical conduit hookup Material: Body: ........................Brass Plunger: .................Stainless Steel Listings and Approvals UL .........................E91021 ULC ..........................1165 FM . . . . . . . . . . . . . . . . . . . . . . . . 2T8A9.AF 2 1/4 IN. (57 mm) 001395 0 ANSUL and INERGEN are trademarks of Annul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MARINEITE, WI 54143-2542 715-735-7411 Form No. F.2001067 ©2001 Ansul Incorporated Litho in U.S.A. ANSUL System Components UL EX-4510 11-1-00 Page 1-4.1 REV.3 Ink". Lever Release Actuator Description The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote man- ual pull station, the pull station must contain the compo- nents necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. I Four actuators are available. Each is designed for a specific component. Add 19/16 in. (3.9 Cm) to height when lever is in the straight up position. Component Material Approvals All Manual Brass with FMRC Approved Cable-pull Stainless UL Listed Actuators Steel Pin (EX-4510) Shipping Assembly Part No. Description 842484 Lever Release (1 1/4-18 mounting thread) - Mounts directly to pressure actuator on 2 1/2 in., 3 in. and 4 in. selector valves. 423309 Lever Release (1 1/8-18 mounting thread) - Mounts directly to a CV-98 electric actuator. Mounts directly to a CV-98 cylinder valve. 70846 Lever Release (1 1/4-18 mounting thread) - Mounts directly to an HF electric actuator. 427207 Lever Release (1 1/8-18 mounting thread) - Mounts directly to the 1 in. and 2 in. selector valves. Mounts direct- ly to pressure operated stackable actu- ator for 1 in. and 2 in. selector valves. Actuator has the handle painted red. S ANSUL and INERGEN are trademarks of Afoul Incorporated or its affiliates. ANSUL INCORPORATED ONE STANTON STREET MARINETFE Wi 54143-2542 715-735-7411 Form No. F-9879-3 ©2001 Ansul Incorporated Litho in U.S A. ANSUL System Components UL EX-4510 5-1-00 Page 1-12 InevE.REV. 4 Cloan Agent Flexible Discharge Bend Description The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra-heavy flexible hose which con- nects the valve discharge outlet to the fixed piping or head- er manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. The discharge bend will withstand a pressure of 9000 psi (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft. (5.5 m) of 1/2 in. Sch. 40 pipe. Shipping Assembly Part No. Description 427082 Flexible discharge bend 842430 Washer Component Material I Thread_Size/Type Approvals Valve End Manifold End 5/8 in. Flexible SAE 100 R2 Special to 1/2 in. NPT Male FMRC Approved Discharge Bend Type AT mate with UL Listed (EX-4510) CV9O and CV-98 Valve 18 7/8 IN. .4 FEMALE ADAPTOR (47.9 cm) (BRASS) 1/2 IN. NPT WASHER MALE COUPLING CHECK SWAGE ON VALVE END .___.[t.nhinif" MANIFOLD/END moose ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MARINEnE, WI 54143-2542 715-7357411 Form No. F-9306-6 ©2000 Ansut Incorporated Litho in U.S.A. ANSUL® Inecj.®1 CIfl A System Components ULEX-4510 11-1-00 Page 1-15 REV. 6 Pressure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. * DIRECTI OF FLOV VISIBLE ORIFICE IDENTIFICATION 002197 Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in. NPT pressure reducer/union 2.94 in. (7.5 cm) 2.04 in. (5.2 cm) 3.31 in. (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material - Thread Size Approvals Pressure Reducer/ Body: Forged 1/2, 3/4, 1, FMRC Approved Union Steel 1 1/4,1 1/2, UL Listed (EX-4510) 2 in. NPT Orifice Plate: Stainless Steel NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. Orifice diameter must be specified when placing order. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED ONE STANTON STREET MARINEITE, WI 54143-2542 715-735-7411 Form No. F-9311-8 ©2001 Ansul Incorporated Litho in U.S.A. 0 ANSUL Ineffi R. Clean Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. Standard nozzles are constructed of brass. NOTE: 2, 2 1/2, and 3 in. nozzles are not recommended in areas that are subject to damage by high velocity dis- charges, such as suspended ceiling tiles. System Components UL EX-4510 11-1-00 Page 1-16 REV 6 3600 Discharge Nozzle Shipping Assembly Part No. Description 417908 1/4 in. NPT nozzle** 417723 3/8 in. NPT nozzle** 417362 1/2 in. NPT nozzle 417363 3/4 in. NPT nozzle 417364 1 in. NPT nozzle 417365 1 1/4 in. NPT nozzle 417366 1 1/2 in. NPT nozzle 426155 2 in. NPT nozzle 426156 2 1/2 in. NPT nozzle 426137 3 in. NPT nozzle Component Material Thread Size Approvals Nozzle L 1 Body—Brass 1/4**, 318**, 1/2, 3/4, 1, 1 1/4, 1/2, 2, 2 1/2, 3 NPT FMRC Approved UL Listed (EX-4510) Size A-In. 13-In. I C-In. Hex 1/4 in. 5/8 1 9/16 21/32 5/8 3/8 in. 3/4 1 5/8 23/32 3/4 1/2 in. 15/16 1 31/32 27/32 15/16 3/4 in. 1 1/8 25/32 7/8 1 1/8 1 in. 113/32 29/16 1 17/16 1 1/4 in. 13/4 23/4 1 1/16 13/4 11/2 in. 2 231/32 11/16 2 2in. 23/8 3 1 23/8 21/2in. 3 31/2 1 3 3 in. 31/2 4 1/8 1 1/4 31/2 NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. Orifice diameter mast be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. UUULC li 0 sted only. ANSUL INCORPORATED, ONE STANTON STREET, MAPINETTE, WI 54143-2542 7157357411 Form No, F-9328-9 @2001 Ansut Incorporated Litho in U.S.A. Size A-in. B-In. C-In. 1/4 in. 5/8 1 9/16 21/32 3/8 in. 3/4 1 5/8 23/32 1/2 in. 15/16 131/32 27/32 3/4 in. 1 1/8 25/32 7/8 1 in. 113/32 29/16 1 11/4 in. 13/4 23/4 11/16 11/2 in. 2 231/32 11/16 2in. 23/8 3 1 21/2in. 3 31/2 1 3 in. 31/2 41/8 11/4 0 ANSUL System Components UL EX-4510 11-1-00 Pagel-16.1 REV.2 . 1800 Discharge Nozzle Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 180° nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8, 1/2, 3/4, 1, 11/4, 11/2, 2, 2 1/2, 3 NPT Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 11/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle P. NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. i - 2 002743 * Orifice diameter must be specified when ordering nozzle. 01 Refer to Orifice Size Chart in Manual Appendix Section. ANSUL and INERGEN are trademarks 01 Ansut Incorporated or its affiliates. ANSUL INCORPORATED. ONE STANTON STREET, MAPINETIE, WI 54143-2542 715-735-7411 Form No. F-99020-1 ©2001 Ansut Incorporated Litho in U.S A. System Components ANSUL System EX-4510 3-1-99 Page 1-16.2 • r Ine1 Nozzle Deflector Shield cIan Agent Description The INERGEN® system nozzle deflector shield is used to control the pattern of the discharge of the INERGEN agent. The deflector shield helps keep the agent discharge away from false ceiling tiles and fragile light fixtures, avoiding damage to them. The deflector shields are constructed of steel and painted with a cameo cream colored paint. They are available in five sizes. Component Material Approvals Nozzle Steel FMRC Approved Deflector UL Listed (EX-4510) Shield Shipping Assembly Part No. A Inlet NPT B Length of Coupling C Overall Length 0 Deflector O.D. E Coupling O.D. 417708 1/2 in. 1 7/8 in. 3 in. 33/8 in. 11/8 in. (4.8 cm) (7.6 cm) (8.6 cm) (2.9 cm) 417711 3/4 in. 2in. 31/4in. 33/8in. 13/8 in. (5.1 cm) (8.3 cm) (8.6 cm) (3.5 cm) 417714 1 in. 2 3/8 in. 3 13/16 in. 4 7/8 in. 1 3/4 in. (6.0 cm) (9.7 cm) (12.4 cm) (4.4 cm) 417717 11/4in. 25/8in. 43/l6in. 47/8in. 21/4in. (6.7 cm) (10.6 cm) (12.4 cm) (5.7 cm) 417720 1 1/2 in. 3 1/8 in. 4 29/32 in. 521/32 in. 2 1/2 in. (7.9 cm) (12.5 cm) (14.4 cm) (6.4 cm) NOTE: There are no deflector shields available for the 2, 2 1/2, or 3 in. models. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED. ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F.94152-1 01999 Ansul Incorporated Litho in U.S.A. ANSUL® System Components UL EX-4510 3-1-99 Page 1-17 Iner 11 K Clean Agent Sy.tem I Cylinder Bracketing Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing compo- nents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coating. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel FMRC Approved UL Listed (EX-4510) 0 [1 Shipping Assembly Part No. Description 845120 200 ft.3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft.3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft.3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft.3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright, for 200, 250, 350, and 435 ft.3 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 ft.3 (12.0 m3) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 ft.3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 ft.3 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft.3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 ft.3 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft.2 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft.3 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) 871683 Weigh rail support - single row 871682 Weigh rail support - double row 871 684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row BACK FRAME CYLINDER CLAMP CARRIAGE BOLT WITH NUT RIGHT BRACKET FOOT CLAMP CHANNEL WEIGH UPPORT / II Ii II II NAIL Multi-Cylinder Single Cylinder UPRIGHT LEFT BRACKET FOOT 002200 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. O ANSUL INCORPORATED ONE STANTON STREET, MARINETTE. wi 54143-2542 715735-7411 Form No. F-9309-7 © 1999 Ansul Incorporated Litho in U.S.A. System Components AIISUI.® UL EX-4510 11-1-00 Page 1-18 REV 3 .. clean Agent Pressure Switch — DPST Description The pressure switch is operated by the INERGENTM agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to either shut down equipment or turn on lights or alarms. The double pole, single throw (DPST) pressure switch is con- structed with a gasketed, water tight housing. The housing is constructed of malleable iron, painted red. A 1/4 in. NPT pressure inlet is used to connect the 1/4 in. pipe from the INERGEN system. The pressure switch can be installed either before or after the pressure reducer in the distribution piping. Minimum operating pressure is 50 PSI (3.5 bar). Shipping Assembly Part No. Description 846250 Pressure switch - DPST Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch Switch: Conduit Inlet: 3/4 in. NPT Female 2 HP - 240 VAC/ FMRC Approved DPST BAKELITE Pressure Inlet: 1/4 in. NPT Female 480 VAC UL Listed (EX4510) Housing: 2 HP - 250 VDC, Malleable 30A - 250V AC/DC Iron 5A - 480V AC/DC Piston: Brass Cover: Brass 3 5/8 IN. (9.2 cm) I- BE CONTROLLED MALLEABLE IRON ,- - -, BRASS RESET 27/8 IN. I FINISH - RED PAINT ' - PLUNGER (7.3 cm) 'I TO ELECTRICAL MOISTURE-PROOF EQUIPMENT TO \ JOINT GASKET NUT _________________ I nol ^0* RING GASKET I I NAMEPLATE 0 O - DOUBLE POLE - I - HEAVY OUTS' I TOGGLE SWITCH I 49/16 IN. WITH FULLY (11.5 cm) ENCLOSED [o o I BAKELITE BASE BRASS PISTON PISTON O RING GASKET OUTLETS - - JJ MOUNTING HOLE - TO POWER 004593 .1 3/4 IN. I ELECTRICAL —j- - - - CONDUIT 19/64 IN. (7.5 mm) 1/4 IN. UNION --' - J TYP. 2 PLACES 1/4 IN. PIPE FROM CYLINDERS 000716 40 BAKELITE is a trademark of Union Carbide Corp. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED ONE STANTON STREET. MARINE1TE, WI 54143-2542 715-735-7411 Form No. F-9327-5 ©2000 Ansul Incorporated Litho in U.S.A. 1 ANSUL® System Components ULEX-4510 12-1-93 Page 1-23 __ 0 ___ Clean Warning Plate - Inside Room With Alarm Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area when the alarm sounds. The warning plate is furnished with four mounting holes for ease of installation. The plate is constructed of aluminum. Shipping Assembly Part No. Description 416265 Warning Plate - inside room with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (64 cm) FMRC Approved UL Listed (EX-4510) 12.00 () WHEN ALARM SOUNDS• VACATE AT ONCE INERGENTM AGENT BEING RELEASED lReiw@m AGOMT LABEL NO. 416265 ANSUL and INERGEN are trademarks of Ansut Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARlNEYrE, Vt/i 541432542 715735-7411 Form No, F-93152 012000 Ansul Incorporated Litho in U.S.A. 7.00 002746 ANSUL Ine jt0mil CIon 1 System Components UL EX-4510 5-1-00 Page 1-24 REV. 1 Warning Plate - Outside Room Without Alarm Description The warning plate is available for mounting outside the haz- ard area to warn the personnel that the space is protected by an INERGENTM system and no one should enter after a discharge without being properly protected. The warning plate is furnished with four mounting holes for ease of installation. Shipping Assembly Part No. Description 416266 Warning Plate - outside room Component Material Mounting Hole Size Approvals Warning Plate Aluminum 7/32 in. (.56 cm) FMRC Approved UL Listed (EX-4510) imill 8.00 -4 WARNING THIS SPACE IS PROTECTED BY AN INERGEN® FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. DO NOT ENTER WITHOUT APPROVED SELF- CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. LnSVn. LABEL NO. 416266 7.00 ANSUL and INERGEN are trademarks of AnsuI Incorporated or Its affiliates. ANSUL INCORPORATED. ONE STANTON STREET, MARINEIrE. WI 54143-2542 715-735-7411 Form No. F-9314-3 ©2000 Ansul Incorporated Litho in U.S.A. ANSUL I INERGEN DESIGNER Version 2.1.2 File: Data file name: C:\Program Files\INERGEN DESIGNER\Inergen Caic Data\06SRWI506F.inr Job: 06SRW1406F Customer: PRO-TECH FIRE PROTECTION Address: 179 ROYMAR ROAD SUITE-G OCEANSIDE CA 92054 REMARKS: ENCINAS WASTEWATER Hazard Area Information Area: SERVER ROOM 20-112 Design concentration 34.5% at 68° Fahrenheit Estimated maximum concentration 41.7% at maximum hazard temperature 75° Fahrenheit Net volume of enclosure 1995.0 cubic feet Minimum INERGEN required 847.9 cubic feet Approximate INERGEN supplied 1065. cubic feet Flooding factor .425 cubic feet of INERGEN per cubic feet of enclosure volume Maximum allowable wall strength 5.0 Ibs./sq.ft. Area consists of one volume Volume 1: Length 21 ft Width 9.5 ft Height 10 ft 1 nozzles. Nozzle identifiers: 301 Agent Storage Conditions Number of cylinders: 3 each containing 355 cubic feet of INERGEN. Total agent 1065 cubic feet Engineering units (ft, cu ft, psia) are specified Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Calculation based on fixed nozzle and pipe sizes Pipe Data Input Sec Sec Nominal Length Elev 90's Side Thru Union! Noz Eql Start End Pipe Size (ft) (ft) Tee Tee Cplg Dia (ft) 1 2 1/2 - 40 T 0.01 0.00 0 0 0 0 38.00 2 3 3/4-80T 1.00 0.00 1 0 0 0 0.00 3 4 3/4 - 80 T 1.00 0.00 0 0 1 0 2 cyl 0.00 4 5 3/4-80T 0.50 0.50 0 1 0 0 3cyl 0.00 5 6 3/4 - 80 T 0.00 0.00 0 0 0 0 Orifice 6 7 3/4-40T 4.50 4.50 0 0 0 1 0.00 7 8 3/4 -40 T 4.50 0.00 1 0 0 0 0.00 8 9 3/4-40T 1.50 -1.50 1 0 0 0 0.00 9 301 3/4 - 40 T 0.01 0.00 0 0 0 1 0.377 0.00 1 (End of Data Input File Printout) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2. 1.2 File: Data file name: C:\Program Files\INERGEN DESIGNER\lnergen Caic Data\06SRWI506F.inr Job Number 06SRWI406F for PRO-TECH FIRE PROTECTION Address: 179 ROYMAR ROAD SUITE-C OCEANSIDE CA 92054 REMARKS: ENCINAS WASTEWATER Acient Storaae Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. 355 cubic feet of INERGEN stored in each of 3 cylinders. Total agent in storage is 1065 cubic feet. Time to discharge 959 cubic feet (90% of INERGEN) is 92.5 seconds Maximum pressure downstream of manifold orifice is 1253 psia Concentrations 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration Area Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. SERVER ROOM 20-112 1995.0 59 1065.0 41.7%at750F 41.2%at680F 34.5%at68°F Sea level equivalent oxygen: 12.3% at 75°F Free Vent Calculation Peak Maximum Wall Minimum Free Area Rate Strength Vent Area SERVER ROOM 20-112 1641.1 cfm 5.0lbs.Isq.ft. 63 sq. in. Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1/2 40 1 0.0 38.0 0.0 MFLD 1033 1021 294.9 2 3 3/4 801 1.0 2.9 0.0 MFLD 1021 1022 294.9 3 4 3/4 801 1.0 2.2 0.0 MFLD 1022 1020 589.9 4 5 3/4 80 1 0.5 4.2 0.5 MFLD 1020 1014 884.8 1 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 File: Data file name: C:\Program Files\INERGEN DESIGNER\Inergen Caic Data\06SRW1506F.inr Job Number: 06SRWI406F Pressure Drop Results (Continued) Sec Sec Nominal Length Equiv Elev Tee! Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 5 6 ORIFICE .261 INCHES DRILL NO. G 1014 431 884.8 6 7 3/4 40 T 4.5 4.8 4.5 431 583 884.8 7 8 3/4 40 T 4.5 6.6 0.0 583 575 884.8 8 9 3/4 401 1.5 3.6 -1.5 575 571 884.8 9 301 3/4 40 T 0.0 0.4 0.0 571 571 884.8 Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fiftings Sec Sec Nominal Length Side Thru Unions/ Eql Start End Pipe Size (ft) 90's Tee Tee Cplgs (ft) 1 2 1/2 40 1 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 3/4 80T 1.0 1 0 0 0 3 4 3/4 80T 1.0 0 0 1 0 4 5 3/4 801 0.5 0 1 0 0 5 6 3/4 80 T 0 0 0 0 Man. Orifice 6 7 3/4 401 4.5 0 0 0 1 7 8 3/4 40T 4.5 1 0 0 0 8 9 3/4 40T 1.5 1 0 0 0 9 301 3/4 401 0.0 0 0 0 1 Nozzle Performance Summary Nozzle Nominal Drill Drill Quantity (cu ft) Area Number Pipe Size Number Diameter Discharged Name 301 3/4 401 V 0.377 1065.0 SERVER ROOM 2O-112 2 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2. 1. 2 File: Data file name: C:\Program Files\INERGEN DESIGNER\Inergen Calc Data\06SRWI506F.inr Job Number: 06SRW1406F Messages/Errors ANSUL 150 bar INERGEN DESIGNER Version number 2.1.2 Calculation based on fixed nozzle and pipe sizes. Calculation done on 7/17/2006 at 2:58:06 PM Pipe schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum pipe pressure for Grade A-5313, A-1 06B Seamless. To determine if other grades are acceptable, verify that the maximum pipe pressures for other grades are equal to or greater than the maximum anticipated downstream pressure. Calculation by Airgas West Fire Protection Gordon E. Swope 1340 E. Mission Blvd Pomona California 91766 Telephone: 909-868-5000 Fax: 909-397-0562 3 End of Printout