Loading...
HomeMy WebLinkAbout2100 COSTA DEL MAR RD; ; FPC2020-0104; Permit(ity of C arlsbad Print Date: 12/07/2020 Job Address: 2100 COSTA DEL MAR RD, CARLSBAD, CA 92009-6823 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2165900100 Track #: Valuation: $569,282.40 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: OMNI HOTEL - CHOPRA 'CENTER: FIRE ALARM TI (49 DEVICES, ADDRESSABLE) Permit No: FPC2020-0104 Status: Closed - Finaled Applied: 06/15/2020 Issued: 06/29/2020 Finaled Close Out: 12/07/2020 Inspector: Final Inspection: Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE TI Fire Alarm System $620.00 Total Fees: $813.00 Total Payments To Date: $813.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fpc1oo -004- Johnson Controls Fire Protection, LP 1, 3568 Ruffin Road South Johnson San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 Fire Detection and Alarm System Product Submittal Project: Omni Hotels & Resorts 2100 La Costa Del Mar Road Carlsbad, CA 92009 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.daniels(jci.com 6/5/2020 REV.#: 1 PROJECT Johnson Controls Fire Protection, LP I/fl 3568 Ruffin Road, South Johnson ' San Diego, CA 9212.3-2597 Controls Tele: (858)633-9100 i-ax: (50E5) bii-i7U7 Fire Detection and Alarm System Products Qty Model No. Description - C.S.F.M. No. 1 4009-9201 INAC Repeater 7300-0026:0214 2 2081-9272 6.2AH Battery N/A 21 4398-9792 Sensor base 7300-0023:0217 21 4398-9714 Photoelectric sioke sersr 7272-0023:0218 2 2190-9163 Control ZAM 7300-0023:0182 7 4336-9103 Strobe Only - 7125-0025:0316 12 4936-9'2 Horn/Strobe 7125-0026:0317 6 HWL-LF Low Frequency Horn 7135-1653:0516 6/5/2020 REV.#: 1 PROJECT 5SimpIEx LifeAlarm Fire Alarm Controls UL, ULC, CSFM Listed; MEA (NYC) 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Acceptance* Additional information. For additional operation detail and application information, refer to Installation Instructions 574-181 and field wiring diagram 842-068. Note: 4100U requires revision 11 software or higher for compatibility. 4010 requires revision 2 software or higher for compatibility. Upto8 NACs 4009 IDNet NAC Extender Optional IDNet I Channel Repeater I 2-Wire IDNet Communications or ' \ \ ' Fiber Optic IDNet Communications or NAC Control IDNet Fiber Optic Transmitter - l•-I ., '5 -, Four additional Class B NACs, rated 1.5 A for Special Application 4007Es, 4010 (shown), appliances; 1 A for Regulated 24 DC appliance power 4010Es, 4looEs, or 4100U Class A, Two Circuit Adapter Module Fire Alarm Control Panel UL Listed to Standard 864 Fire Alarm Control Panel with Conventional NACs External Accessories Figure 1: 4009 IDNet NAC Extender IDNet communication fiber optic transmitters: connection reference drawing For applications requiring the data integrity available with fiber optic communications Available as Class B or Class X Mounts in standard six-gang electrical box External battery cabinet for 18 Ah batteries Introduction ADA compliance. Complying with the notification requirements of ADA (Americans with Disabilities Act) may require more notification appliance power than is available within the fire alarm control panel. When additional power is required, a 4009 IDNet NAC Extender can provide up to 8 A of NAC power with up to eight, supervised reverse polarity NACs. Location flexibility. The 4009 IDNet NAC Extender can be mounted close to a compatible dedicated host panel or can be located remotely for convenient power distribution. Multiple operation modes and multiple connection options further increase location flexibility. uLc listed model is 4009-9202cA. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety code. See CSFM Listing 7300-0026:214 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. are the property of Tyco Fire Protection Products. S4009-0002 Rev. 15 9/2019 Features Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Four, Class B NACs are standard: Rated 2 A each for conventional reverse polarity 24 VDC notification appliances and providing multiple operation modes. can be selected to provide synchronization for Simplex visible notification strobe flashes. Capable of controlling TrueAlert non-addressable notification appliances operating with SmartSync two-wire control mode. Input control options: IDNet addressable communications from a 4007E5, 4010, 401 OES, 4100U, or 4100ES Fire Alarm Control Panel. See note. Or from one or two conventional 24 VDC NACs with multiple output control options IDNet communications control benefits: Provides status monitoring and individual NAC control using a single address per 4009 IDNet NAC Extender Supports IDNet 'Device Level" earth fault location WALKTEST operation is available with either input choice Internal 8 A power supply/battery charger: Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet Provides status monitoring of battery, input power, and earth faults Rated 8 A for "Special Application" appliances; including 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/ strobes Rated 6 A for "Regulated 24 DC" appliance power Optional 4009 IDNet NAC Extender modules: IDNet Communications Repeater provides Class B or Class A output IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class X 10 Simplex 4009 IDNet NAC Extende for Control with IDNet Communications or onveniona. .NA1t Application and operation information IDNet addressable communications compatible. Up to 10,40C9 IDNet NAC Extenders can be controlled for each 4007E5, 4C1OES, 4100U, cc 4100ES IDNet communications channel; up to 5 can be coitrolled cn the 4010 IDNet communications channel. Each output IACcan be individually controlled for general alarm or selective area notification requiring only one point address for each [Extender. Individual Extender NACs can alsn be manually controlled from the host panel. IDNet controlled extenders will inform the host panel of troubles using IDNet communications. 4007E9, 401OES, 4100ES, and 4100U control panels control using nulti-pointrules, refer to data sheet 54090-0011 for details. Optional IDNet repeaters. IDNet communications can be repeated wi::h the cational IDNet Repeater Module or with the optional Fber Optic Receiver Module. Up to 100 of the IDNet channel points can be repeated once (-eferto Typical IDNet connection example and 40D9 IDNet NAC Extender specifications for details). Repeated IDNet comm:Jnications also support the "device level earth fault location utility of the host panel Hardwire control applications. For applications where an existing (or new) ccnventional NAC needs additional power, the 4009 IDNet NC Extender can be controlled directly from the NAC. Either one or two NACs, from either the same, or from different host fire alarm con-To) panels, ca a - be connected to control the 4009 IDNet NAC Extender outOut NACs. Mu'tiple control selections provide flexible operation. (See Hardwire Conrrcl Connection Information for more detail.) Alarms from the host panel will activate the four, 4009 lDet NAC Extender NACs (or opt onally, 8 NACs) :o extend the alarm. The 4009 IDNet Extender monitors itself and each of its oLtput NACs fontrouble conditions, including earth faults. Extenders wired tc conventional NACs will indicate a trouble by opening the path to the NAC's end-of-line resistor, but retaining the ability to respond to alarms. Individual troubles are also annunciated by LEDs located on the 4009 IDNet NAC Extender main cir:uit board. Refer to Service diagnostic features for mcre diagnostic information. - Product selection Table 1: S:andard models Mode! - Descrqtion - - - 120 VAC input 4009 IDNet NAC Extender wi:h 4, Class B NACs 240 VAC input land 8Apowersupply 4009-9202CA (ULC listed model) 120 VAC input 4009-9201 has been seismic ;ested and is certified to IBC and CBC standards as well as to AscE:7 categories A through F, requires battery bre':ke::s as detailed on data sheet S2081-0019 Table 2: Optional mod iles (for on-site installation) Model _--Description 4009-9807 Addicionel four noint NAC module, fated 1.5 A Special Application maximum appliances; 1 A for Regulated 24 DC appliance power, Class B 4009-9808 Dual Class A adapter (for two NAC outputs) Select as required (4 maximunj 4009-9809 IDNeL Repeater output is Class A o Class B Select either an IDNet Repeater or a Finer Untie 4009-9810 ' . . . Class B Fiber Optic Receiver Receiver as required; one transmit:ercan corr.ec: - 4009 9811 Class A(IDNet) Class X (fiber to one receiver 4009-9805 iRed Appliqué fcr door Select if required - 2975 9801 . ... . .... ......Semi-FluehTrim Kit - Beige tim ....................................................................... .. ... .... .... ... 7/16 in wide (78 mm) use if required for emi 2975-9802 Red tam t1ushinstallations Table 3: Battery selection (se-ect tattery size using system requirements) Model Description Comments 2081-9272 13.2 An Battery, "2'vDC . . . . 2081-9274 110 Ah Battery, 12 VDC wo batteries are required 24 VDC operation. 20 81 9288 J27 h Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabiret twc batte i-_ arc- required, 24 VDC operation Table 4: External accesscries-select using system requirEments) Comments Model Description 4090-9105 - . ....... ........- , Class B:operaiion . Mounts in six-gang electrical box, refer to ................................................ - . ........... - ....- IDNet fiber optic Transmitter lDNer Fiber Optic mounting .4090-9105/9107 information for mounting details 4090-9107 Transmitter Class X operation Note Class B Fiber Transmitte Re C o highe 15 NOT COMPATIBLE with Ciass B F be- Rece ver before RevJ. 4009-9801 External batters, cabinet for up to .13 Ah batteries, beige 6-1/4 in. Wx13-1/2 in. Hx5-3/4 in. Dt413mmx -, - :.43 mm x 146 mm) 4081 series . End-of-Line resistor harnesses; see -data sheet S4081-0003 for details - Page 2 - T , S43090C2 Rev. 15 9/2C' E+ SimplEx 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs IDNet addressable communications channel, shown Class B (Style 4) Conventional NAC operation (horns) Output NACs, four standard, eight with expansion option Typical IDNet connection example 4007ES, 4010, 40I0ES, 4100ES (shown), or4100U Fire Alarm Control Panel Select conventional or SmartSync - operation per NAC TV' Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements, some wiring is not shown.) SmartSync operation (horns and strobes) 4009 IDNet NAC Extender with L optional internal IDNet Repeater Conventional NAC operation (strobes) Repeated ,IDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) Figure 2: Typical IDNet connection example Note: Up to 104009 IDNet NAC Extenders may be connected using 4007ES, 4010E5, 4100U, or 4100ES IDNet channel, up to 5 on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Page 3 S4009-0002 Rev. 15 9/2019 40C lDNet NAC Extencer ftr Control with IDNet 0mmuncations o Convertiori, NACs Typical fiber optic system ccnrections Two fiber cables, 3000 ft 4090-9105. Class B (914 m) maximum distance (Style 4 Ouput Fiber Oti Tarsmitter \ 7Outp ut NACs IDNet addressable ccmmunbati-ars ;channe Class 3 (Style 4) or class A (Style 6), Class B shown Four fiber cables, 3000 ft (914 m) maximum distance \ 4009 IDNet NAC Extenders internal IDNet Fiber Revers 24 VDC power for fiber optic transmitters / 4090-9107, Cless A (Style 7) Output Fiber Qptic Transmitter / / / Repeated lDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel 4007ES, 4010 (shown), 4010ES, 4100ES, or4100U Fire Alarm Control Panel Figure 3: Typical fiber optic system connections - Note: Up to 104009 IDNet NAC ExterderE may be con.ected p& 4007E5, 4100E, or 4O10ES. Up to 5 LiJ9 DNet N A :tenciars may be :onrected on the 4010 IDNet channel. IDNet corimu- cabons car be repeated only on-e (ca- pass through only one series cor nec:ed rakeate- or one ibe- optic receiver). Fiber optic transni:ters ccnnec to on],,, one eceker in a 409:lDNeT NAC Extender. - Hardwire Control Connecti Dn Information NAC Input Selections. Tie 4009 lONer r/.M: Extender :an be seected to: - Track input NAC operation or to -pro':icie a locally geneated code, selectabte- u -g NAC input. If selected for local coding. NAC oLtpu:s :en be either Temporal Coded or 63 Beatslimin March Time Coded, ore ccde seection ocr e':ender (input NACs must be on continuous with Alarm). Additionally, NAC outputs :an be selecte: to provide tie Simplec strobe synchronization s;gnai. This signal will s,-ncironi7ebie1asies c synchronized strobes bL:: will be ignored by free-run ctrobes and audible dc-Acer 'Strobes are for operation by nonooded NACe) NAC input to NAC output control can :e selected fc standard and option.3 NACs ocr the following table: Table 5: Conventional NAC c'utputDperaticn cptions IlnPIt - A C. [ifAC1 l\lAs1 ard2,5 and 6 N,ACs1-4 _JCs1-a NAC2 )NIAS3and4,7 and 8 NACs 5-8 - Table 6: SmartSync NAC Output Opertioi nput iAC Cont oIFunctici AC 1 Srobe Cbr:ro . . - ........................-.- ...... rt .............-----------------iAllNACoutputs,1-8) n AC 2 Ho Conol . Page 4 54009-0002 Fey. 15 9/2019 SimplEx 4009 IDNet NAC Extender for Control with lDNet Communications or Conventional NACs SmartSync Notification Appliance Control The TrueAlert Notification Appliance product line includes addressable and non-addressable operation. Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet NAC Extender: TrueAlert non-addressable models with SmartSync operation allow audible notification to be separately controlled over the same wire pair that controls visible notification. 4009 IDNet NAC Extenders can be selected to provide SmartSync operation whether controlled by IDNet communications or conventional NACs. IDNet control allows output NACs to be individually selected for conventional or SmartSync operation. With NAC input control, all output NACs are selected for either conventional or SmartSync operation. Refer to data sheet 54009-0003 for TrueAlert Addressable operation details, contact your local Simplex product supplier for further information on specific TrueAlert notification appliances. Hardwire control NAC connection cne-line reference diagram Up to eight (8) output NACs total; hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input (see Note 1) I-0 __________________ Conventional NACs With hardwire control, NAC outputs are all Output conventional or all 43- NACs SmartSync operation J [1 Extender 4009 IDNet NAC Fire Alarm Control Panel with Conventional NACs / I :---------- I Class A operation, either mo----------- NAC 2 input 4009-9808 Dual Class A Adapter (optional, see Note 1) To additional 4009 IDNet NAC Extenders (up to four (4), 4009 IDNet NAC Extenders per NAC); see Note 2 Figure 4: Hardwire control NAC connection one-line reference diagram Note: For separate audible and visible output NAC control, or SmartSync NAC output operation, 2 input NACs are required. NAC 1 is "on-until-reset" and NAC 2 is "on-until-silenced". To synchronize strobe flash outputs for up to 44009 IDNet NAC Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905-9914 for Class B operation, 4905-9922 for Class A operation) or, if available, from a NAC selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance. Page 5 S4009-0002 Rev. 15 9/2019 Simplex 4009 IDNet NAC Extender for Control with IDNet Cornminications or Conventional NACs 4009 IDNet NAC Extender specifications Table 7: Input ratings Specification Rating 20 1 VAC input (4009-9201) 3A@ 102 VAC -132 VA, 60Hz 240 VAC input (4009-9301) 1.5A @204 VAC -264 VAC, 50 Hz /E-0 Hz Hardwire control from external NACs. Irput requirements Conventional reverse pclarity operation 5 mA maximum; 16VDCto33VDC Table 8: Output ratings Specification - Rating, Total rating [8 A, Special apolication appliances 6 A, regulated 24 DC appliance power Standard NACs 2 A each, specal application or regulated 24 DC appliance power Optional NACs (requires 4009-9807) 1.5 A each, Special Application appliances 1 A each, Regulated 24 DC apptance power Special application appliances Simplex non-addressable horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product representative forcompatible appliances) Regulated 24 DC appliances Power for other UL listed appliances; use associated external s',nchronization modules where - required Strobe operation p Up to 33 strobes for each NAC can be synchronized; output NACs configured for,Simplex synchronized strobe operation are synchronized to each other Auxiliary output 1500 mA @ 24 'JDC nominal Table : Optional modules ratings Specification ' Rating_______________________ I Input power IDNet input, one address 70 mA @ 24 VDC, system supplied Maximjm distance from IDNet source is 2,500 ft (762 m) IDNet Repeater Module (4009-9809) 1 DNet output specifica:ions Repeated IDNet output for up to 100 devices (total IDNet devces iot to exceed 250 for each cdannel) Maximum distance to farthest device is 2,500 ft (762 m Total distance V)cluding "T-taps" is 10,000 ft (3048 m) Class A loop maximum distance is 2,500 ft (762 m), no '1' taps Table iC: Fiber optic receiver modules Specification, '" Rating ____ Input current 4009-9810 , Class B, 65 mA @ 24 VDC, system supplied 4009-9811 Class X, 80 mA @ 24 VDC, system supplied I et output specifications -------- ISame as those for repeater module Fiber optic transmission distance 3000 ft (914 m) maximum Table 11: General specifications Specification '1 - Rating Operating temperature 32° F to 120° F (0° C to 490 C) Operating humidity range 10% to 90% RH from 32° F to 104° F 0° C to Wiring Connections* Terminal blocks for 18 AWE (stranded) to 12 AWE (solid) Note: * Metric wire equivalents: 18 AWE = 0.82 mm2; 12 AW3 = 3.31 mm2 Page 6 54009-0002 Rev. 15 9/2019 £5impIEx 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Fiber optic transmitter specifications Table 12: Fiber optic transmitter specifications Specification Input voltage Rating 118.9 VDC -32 VDC from compatible listed fire alarm supply Input current 4090-9105,_Class B, 30 mA @ 24 VDC 4090.9107, ClassX, 35 mA @24V - ....................- . ........ - Fiber optic connections and cable requirements Multimode, graded index, 50/125pm, 62.5/125 pm, 100/40 pm, or 200 pm Type ST connectors --- les ...__. ........___......_._..... 4090-9105, Class B_operation, two fiber cab required 4090-9107, Class X operation, four fiber cables required Module size (with mounting bracket) 6-13/16 in. W x 3-3/4 in. H x 1-1/8 in. D (173 mm x 95 mm x 29 mm) On-board status indicators Green LED flashing = transmit Red LED flashing = receive Separate red LED on 4090-9107 = Class X receive Communications Simplex IDNet Fiber optic transmission distance 3000 ft (914 m) maximum Wiring connections* Operating humidity Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) 10% to 90% RH from 32° F to 104° F (0° C to 40° C) Operating temperature 32° F to 120° F (0° C to 49° C) * Metric wire equivalents: 18 AWG = 0.82 mm2; 12 AWG = 3,31 mm2 Page 7 S4009-0002 Rev. 15 9/2019 SimpL.Ex 4009 IDNet NAC Extender for Contrc, with DNet Communications or Ccnventional NACs 4009 IDNet NAC Extender mounting and module placement information Additional fcur point module shown model 4009-9807. Cabinet depth 16-1/4" (413 mm) Pi !4-1f4" (108 mm) 10-29/32 (277 mm> Door, 5I8 - t (16 mm) thick B o - 0 0 Optional lassA 07 Additional Fou"l 13-1/2 (343 mm) odule (shown with I adapter modules ssAadapters>J © Exposed cabinel ~qpoint dimension b - semi-flush motmi V (25.4 mm) Knockout's for screw 1-3/8 I oLft.1 IDNet repeater or W (35 mm) with or nail mounting holes Fiber optic receiver J Ii semi-flush trim _ e S _I -- o OD —12"(305 mm) Battery location, no conduit entrj or wiring in this area (12.7 Ah battery outline shown) 0 Serni-flusn trim option Non-power limited wiring area (AC input) 1-3/16 wide (30 rim), Wall surface reference for sem -flush mount Figure 5: 4009 IDNet NAC Extender mounting and module placement information Note: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module instal ation instructions and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC extender cabinet with ddor detail - .:- - Optional red appliqué ;y. •. ...... (4009-9805) _'DII II] _NACIEXTENDER so Figure 6: 4009 IDNet NAC extender cabinet with door detail Page 8 S4009-0002 Rev. 15 9,2019 Simplex 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs 4090-9105/9107 IDNet fiber optic transmitter mounting information Surface mount box: Simplex model 2975-9217 (ordered separately) Flush mount masonry box: use 6-gang box, RACO # 960, 2-1/2" deep (64 mm), or RACO #965, 3-1/2" (89 mm) deep, or equal (supplied by others) 0 0 0 0 0 0 c c 0 0 0 0 0 0 ~:3 0 qo ___________________________At•@1111 0 •WAi•0iWi01W' Flush mount ganged boxes: ninimum depth-, six, RACO # 400 or equal, (supplied by others) _1' Ell o o 0 0 0 0 o 0 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown, Class A (Style 7) output 4090-9105, Not shown, Class B (Style 4) output INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. Six-gang blank cover plate Mulberry Metal Products 97156 or equal (by others) Service diagnostic features Power-up self-diagnostics. Upon power-up, the 4009 IDNet NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are communicated to the host control panel and are also displayed on diagnostic status LEDs in the 4009 IDNet NAC Extender. When connected via IDNet communications, detailed status information is available at the host. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door mounted reference label. The 4009 IDNet NAC Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. LED Status Indicators are provided for the following: Each NAC (standard and optional) has a dedicated yellow LED that: - During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit. - During an alarm, the LED follows the NAC output (on steady or flashing with coded output). Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble will then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. AC power status is indicated by a green LED that is on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. Page 9 S4009-0002 Rev. 15 9/2019 Simpkx 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NAC-c: 4009 IDNet NAC extender current ca'culation chart Step 1. Calculate the basic exterder battery requirements (minus NAC loads) Panel, NAC Options, and Auxiliary Power (underli-ed model nu-Tbers are apti anal mccules). i Model Description lSupervisory Actual Alarm current Actual alarm current supervisory 4009-9201 120 VACinput Basic Pane 85 mA 85 mA 85 mA 185 mA 400993 RAC ....f--- 4009-9807 Additional four joint NAC 40 mA + z0 mA 4009-9808 Dual class A_adapter (no additional _current) - - - - - (500 mA Auxiliary power output + (300 mA maximum) - maximum) Basic panel supervisory current =[S Basic panel alarm current - = [A2] Step 2. Calculate IDNet output module and devi:e current (if t. sed) 4009-9809 'IDNet Repeater 70 mA .0 mA — ---Selctonefo -.---- ...--------- Fiber * Optic Receiver, C ass 3 55 mA + .55 mA + 4009-9811 * Fiber Optic Receiver, Cass each exter-der .30 mA :30 mA IDNet devices (tonnected to repea:er or receiver bcve), 0.7 mA each, Total devices x 0.7 + Total devices x 0.7 + maximum of 100 mA each mA each Note: IDNet Fiber Optic Transmitter curren: DNet rrcdu e supervisory current [S2] is supplied from the host fire alarm ccntrcl panel IDNet rrodue alarm current . = [A3] Maximum available current = 8 A* auxiliary pcwer output - [Al] IDNet mod le current - [A3] *8A iances; 6 A.for regula:ed 24 DC apoancax NAC current =[A4] Step 3. Calculate actual NAC loading (Linitec to available NAC current per Ste:o 2.) NAC type NAC circuit INAC :m currnt Standard panel NACS, 2 A maximum fo- each 'LAC - Circuit . + Circuit + Circuit 3 + Circuit 4 Optional four point NAC module, 1.5 A maximLm special ap,oli:atic.n rat.ng, I A max mum regulated 24 DC rating, per NAC Circuit 5 + Circuit Circuit + -. Circuit 3 + Total actual NAC load alarm current = [A5] Step 4. Calcul'.3te total supervisory current ITotal supervisory current = Basic panel currert [SI] - IDNet Mocule current [52] = I Step 5. Calculate total alarm current ITotal alarm current = Basic panel current [42] + IDNet module current [A3] + actual NAC Current [AS] © 2019johnsoo controls. All rights reserved. Al ;peci9catians and other informatic.n shown were cu-rent as of document revision and are subject to change without notice, Additional listings may be appfcab:e, contact ycur lo.:al Simplex® preduct supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in This material are T arks and/or registered marks. Lriauthoriz M use is strictly prohibted. NFPA 72 and National Fire Alarm code 3re registered trademarks of the National Fire Pro:ection 'v.so:.a:ion (NFPA). S4009-0002 Rev. 15 9/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0026:0214 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4009-9001, 4009-9002, 4009-9101, 4009-9102, 4009-9201, 4009-9301, 4009-9401 Notification Appliance Circuit (NAC) Power Extenders. Refer to listee's data sheet for detailed product description and operational considerations. Unit components: 565-594 Power Supply 565-569 Style Y Signal Card 565-358 Voice Controller Card 562-907 Amplifier Board 565-388 Style Z Signal Card 4009-9807 NAC Option Card 4009-9810 Fiber Receiver 4090-9105-9107 Fiber Transmitter 4009-9809 IDNet Repeater 4009-9808 Class A Adaptor 4009-9803-98044 Circuit NAC Card 4905-9929 Isolator Module 4009-9806 Earth Detect Module 4003-9803 Remote Microphone Module *40099812 Triple Channel True Alert CIs A *4009-9811 Fiber Receiver, Class A, IDNET INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The NAC must be fully supervised and must have the secondary power supply capable of operating the system for at least 24 hours (battery standby) in the normal condition and followed by not less than 5 minutes of alarm as required by code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power extender units for use with listee's separately listed fire alarm control units. *Revision 12-13-18 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5®SimplEx Fire Alarm Control Panel Accessories Listings* System Baleries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger I'1Iit*I Rechargeable, sealed lead-acid batteries: Lead-calcium grid structure with immobilized electrolyte in absorbent separator Low maintenance with no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover .xith high reliability dual seal construction TilL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ali, depending on control panel cabinet sze Larger batteries, up to 110 Ali, mount in exterial battery cabinets with models available with internal cIargers Battery cabinets with chargers: Battery cabinets with charger communicate with their connected fire alarm control panel and are avail able for 4I00ES/4010ES/4100U Series and 4010 Series panels )cst ri nti r Simplex® rechargeable sealed-lead acid batterie; çrovide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances ae both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house large: batteries with battery chargers available in some battery cabinet sizes. :jjv Iiii ps Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. - Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Remote Battery Cabinets are Available for Larger Battery Requirements I UT!1 .Ifl1 (flhI1Jl1Jij Shipping. Sealed lead-acid batteries are shipped via ground or sea transportation only. They are not shipped via air. Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or cn its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Seismic Activity Applications. Battery brackets are available for systems tested for compliance with specific batteries. Please refer to data sheet S2081-0019 for details. * Refer to details on page 4 and to the referenced individu l product data sheets for aguncy listing status of battery cabinets and chargers. The batte les detailed in this documen. meet the requirements of UL, ULC, and Factory Mutual fir use with respective eqipnent battery chargers as listed on page 3. Contact your local Simplex product sipplier fir proper battery selection per system requirements. Listings and approvals under Simpex Time Recorder Co. are the property of Tyco Fire Protection Products. S2081-0006-21 1212014 ~ Battery Construction Reference Actual appearance will vary with battery size. outer cover hole Quick connect or post type terminal (type varies with batters, size) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Inner Absorbent separator used to immobilize electrolyte Semi-permeable Lead-calcium grids / membrane separator Cell group Cell case (high impact polystyrene) Battery Size Specifications Battery Model Capacity 20 Hour Width* Depth* th* Height with Approximate Discharge Rate Terminals Weight* (2O81 6.2 Ain 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10Ah 6(153mm) 4-1/16(103mm) 4(102mm) 9.2 lbs (4.2kg) 2081-9288 12.7 Ah (153 mm) (102 mm) 4(102mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9" (229 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) 2081-9279 110 Ah 11-3/16" (284 mm) 10-1/2" (267 mm) 9" (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. General Battery Specifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) S2081-0006-21 12/2014 NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application informat:on Simplex Control Panel Model Series (see legend and notes below) Battery Capacity 4003EC 400 4R 4007ES& 4006& 4009 01 0 4OIOES 4I 00ESi 4100&4120 Model 4005 4008 (all models) 41D0U (2 4 or 6-Unit) 2081-9272 6.2 Ah 2081-9274 10 Ah 2081-9288 12.7 Ah I I I 1 I I I I I 2081-9275 18 Ah Ext Note 3 1 Ext Ext Note 2 2081-9287 25 Ah Ext Note 3 NA 2081-9271 Ext Ext 33 Ah Ext Note 3 Ext NA NA Note 3 I / Ext rectang ir 2081-9276 33 Ah Ext Note 3 Ext NA NA Note 3 I 1 I 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 20r3 bay Ext 2081-9279 110 Ah Requires external battery cabinet, compatible with 4100ES, 4010ES, 4100, and 4120 Series only I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment attery ciargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. Some control panel models are listed for battery replacement reference only. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 20E1-9276 2)81-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33Ah 50 Ah 110 Ah 2081-9280 :S1 NA NA NA NA NA I OOU,and + 2081-9281 multiple 1 I I I I NA 2081-9282 4009-9801 multiple I NA NA NA NA 4009-9802 multiple I NA I NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287, 2081-9271 2081-9276 2081-9296 2081-9279' Cabinet Panel Compatibility 18 Ah 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 / I 1 I I NA 4081-9302 4081-9306 4100ES 4O1OES NA NA N A NA 4081-9308 and 4100U * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. / = Can be placed in the respective equipment cabinet NA = Not applicable/not compatible 3 32081-006-21 12/2014 External Battery Cabinet Specification Reference Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red batteries 4003-9860 Beige Multiple Intended for use with 4003EC systems, for up to 33 Ah 9-1/2" H x 24" W 9" D batteries (refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 40099801* Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 5-3/4" D FM batteries* I with locking solid door and battery I harness; for close-nippled mounting to (413 mm x 343 mm x 146 mm)* For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions Battery cabinet with charger for the 4010 and 4081 -9301 Beige 4004R fire alarm control panel; for up to 50 Ah 120 VAC batteries; with front door 22-1/2 Wx16-3/4 H x 8-3/8 D 4081-9302 Red Listings include: UL, ULC, FM, CSFM, and MEA (572 mm x 425 mm x 213 mm) (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model & Color Cabinet Description Compatible Charger Description Dimensions Listings Chargers 4010-9xxx 4010ES Main System Supply Series (MSS) 4100-9xxx 4100E5/4100U System Power Series Supplies (SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100E5/4100U Additional SPS 2081-9280 batteries; includes 4100-5113 4100-5125 Listings Red 80 A battery fuse, 26-1/2" W x 12" H x 12" D include: UL terminals and 4100-5126 4100E5/4100U Remote Power (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100-5127 Supply (RPS) cables; see data 4100-5120 sheet for details 4100-5121 4100ES/4100U TrueAlert 4 100-5122 Addressable Power Supply (TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 4I00ES/40I0ES/4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8" W 13-1/2" H x 14-5/8" D 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red 220/230/240 VAC, CSFM, and MEA (NYC), see data sheet for multi-tapped details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. B®S i rn p1 EX Tyco Fire Protection Products Westminster, MA 01441-0001 • USA S2081-0006-21 12/2014 www.simplex-fire.com 02014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. B®SimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed, FM Approved; TrueAlarm Analog Sensors - Fhotoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories I1tui*i TrueAlarm analog sensing provides: Digital transmission of analog sensor values via iDNet r MAPNET II two-wire communications For use with the following Simplexw products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series zontrol panels; and 4008 Series control panels with reduced featire set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equigpd. for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis ofach sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensivi:y testing requirements; automatic individual senscr calibratoi check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent pe foot Ability to display and print detailed sensor information n plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Three fixed temperature sensing thresholds: 135' F, 155'f and 190° F Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-S529 Louvered smoke sensor design enhances smoke capture Ly directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LEDalarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-002 For photo/heat sensors, refer to data sheet S4098 .0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pinuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026'217tra1.wab1e vases and/or conditions concerning material presented in this document Acted for use - City of New York Department of Buildings - MEA35-93E. Additional listings irzy be applicable, contact your local Simplex product supplier for the latest status. Listirgo and aperroaals under Simplex Time Recorder Co. are the property of Tyco Fire Protection PacdLctS. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measuremen: digitally communicated to the host control panel usimr Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined, and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction ian the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The aiarrn set point for each TrueAlarm sensor is determined at the he st control panel, selectable as more or less sensitive as the indi'idual application requires. Timed/Multi-Stage Selection. Senso: alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive dui ing day). Control panel programming can also provide multi -stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of t:ouble, the details are annunciated at the control panel and that sensor base's --ED wall be turned on steadily. During a system alarm, the control, panel will control the LEDs such that an LED indicating a troube will return to pulsing to help identify the alarmed sensors. S408-0019-23 8/2017 TrueAlarm Sensor Bases and Accessories 11..111*] l4I I (*1 Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on(pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test Ei-ii 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) ALARM l Simplex DAscrinti TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. I rrnrni Electrical Box Requirements: (boxes are by others) Without relay in the box: 4" octagonal 0r4 square, 1-1/2 deep; single gang, 2" deep With relay in the box: 4" octagonal or 4" square, 1-1/2 deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference-. c 0 _ 1-1/2" (38 mm)' minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) VRela'y Sz. -1/2" X 3.75 in 3)(64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8"X 1-1/4 X 11/32 (1 in 3)(60.4 mm X 31.8 mm X 8.6 mm) t~Mr NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 6-3/8" (162 mm) 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" flush box 4-7/8(124mm) "I 15/16" I (24 mm) . a TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 S4098-0019-23 8/2017 TrueAlarm Sensors I11I Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. UL & ULC FM Spacing, Either Fixed Setting Spacing I Temperature Setting 135° F/190° F* 60ftx60ft 20ftx20ft(6.1 m) for ixed (57.2°C! 88° C) (18.3 m) temperature only; RTI = Quick 50ftx50 fit (15.2 m) for fixed 155° F 40 ft x 40 ft temperature with either (68° C) (12.2 m) rate-of-rise selection; IRTI = Ultra Fast ply only to the 4098-9734 sensor Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response Built-in insect screens TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is notnormally a factor, except for impact on area smoke flow. T H 4-7/8' (124 mm) LED status indicator 2-1/8' (54 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 and 4098-9734 Heat SAnnrs TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at tie control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). The 4098-973,-- sensor provides an additional 190° F (88° C) set pcint. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise eature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a u:ility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature zan provide freeze warnings cr alert to HVAC system problems. Refer to specTh panels for availability. T 4 4-7/8' (124 mm) LED status indicator 2-3/8' (60 mm) EIET 4098-9733 Heat Sensor with Base (6 4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Jfe Safety is a factor, the use of smoke detection is highly recommended. VTT1 iruri Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the Natio',al Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivit selection, refer to Installation Instructions 574-709. S4098-0019-23 8/2017 TrueAlarm Analog Sensing Product Selection Chart TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model* Color Description Compatibility ' MóuntinRequirement (4098-9792) White Standard Sensor Base No options 4" octagonal or 4" square box, 1-1/2" mm. depth; or single gang box, 2" 4098-9776 Black mm. depth 4098-9789 White Sensor Base with connections for Remote LED Alarm Indicator or 2098-9808 Remote Alarm Indicator or 4" octagonal or 4" square box 4098-9789 ND White Unsupervised Relay 4098-9822 unsupervised Relay Note: Box depth requirements - 4098-9775 Black depend on total wire count and wire size, refer to accessories 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9791" White Base with connections for LED list below for reference. Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible 2-Wire Sensor Supervised Relay 4098-9860 Supervised Remote Relay with the 2120 CDT 2098-9808 Remote Alarm Indicator or 4098_9780** White Base with connections for LED Indicator or Unsupervised Relay 1 4098-9822 Unsupervised Relay I TrueAlarm Sensors Model* I Model* I Description 4098-714i I White 4098-9714 IND 1 I Photoelectric Smoke Sensor Compatibility Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Mounting Requirements, Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal or electrical box 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal box, 2- 4098-9860 Supervised Relay, mounts remote or in base For use with 4098-9780 base electrical box - 1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang Bases 4098-9789, 4098-9791, and 4098- Single gang box, 1-1/2" minimum depth stainless steel plate 9780 4098-9822 Unsupervised Relay, tracks base LED status; Bases 4098-9789, 4098-9791, and 4098- 4" octagonal box, 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box 9780 extension ring Bases 4098-9792, 4098-9789, Required for surface or semi-flush mounted 4" 4098-9832 Adapter Plate 4098-9791, and 4098-9780 square box and for surface mounted 4" octagonal box * Note: Model numbers ending in IND are assembled in India. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2) UL Listed Operating Temperature Range 32" to 100" F (00 to 38" C) with 4098-9733 Neat Sensor Operating Temperature with 4098-9714 Smoke Sensor Range With 4098-9734 Heat Sensor 32" to 122" F (0" to 50" C) 15" to 122" F (-9" to 50" C) 32" to 150" F (0" to 66" C) Storage Temperature Range 0" F to 140" F (-18" C to 60" C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 rn/mm) Housing Color Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power I Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) SIMPLEX, and the product names listed in this material are marks and/or registered mar/es. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of/he National Fire Protection Association (NFPA). ccim nI Westminster. MA • 01441-0001 • USA S4098-0019-23 8/2017 - - - - - -- wwwsimplex-fire.com 0 2017 Johnson Controls. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 cf 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098*9775, *..9776 *.9777 -9780,-9780E, -9789, -9789E, 9789TSP, -989TTP, -9791, -9791E, -97911SP, 9791TTP,-9792, -9792E, -9792TSP, 97921TP, -9793, -9793E, -9793TSP, -9793TTP,-9796. -97961SP, -97961TP; GSA4098-9780, -9792, -9793, and -9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Refer to listee's printed data sheet for additional detailed prcduct description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Models 4098-9775, -9776, -9777, -9780,-9780E, -9789, -9789E, 97891SP, -978TTP, -971, -9791E, -9791T5P, 979111P,-9792, -9792E, -97921SP, 979211P, -9793, -979.E, -9793TSP, -97931TP; G5A4098-9780, -9792 and -9793 are intended for use with: Models 4098-9714 aid GSA4098-9714 photoelectric smoke detectors (CSFM Listing No. 7272-0326:0218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:0231:; and Models 4098-9733, GSA4098-9733, 4098-9734 and GSA4098-9734 heat detectors (CSFM Listing No. 7270-0026:0216). Models 4098-9796, -97961SP, -9796TTP, GSA4098-9796 are only intended for use with Models 4098-9754 or. GSA4098-9754 photoelectric smoke detector (CSFM Listiig No.7272-0026:0218). These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. Refer to listee's Installatior Instruction Manual for details. *Rev.32-08-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed !\ . the test results and/or other data but does not make an independent verification of any claims. This listing is not / an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installatici instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9714, -9774, -9714T5P, -9714TTP, -9754 -9754T5P, -9754TTP; G5A4098-9714, and -9754 analog photoelectric type smoke detectors. Models 4098-9754, -9779, -9754TSP, -9754TTP; GSA4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (135°F fixed temperature and 120°F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed compatible fire alarm control units. Units are intended for use with smoke detector bases Models 4098-9789, -9789T5P, -9789TTP, -9791, -9791T5P, -9775, -9776, -9777, -9791TTP, -9792, -9792TSP, 9792TTP, -9793, 9793TSP, -9793TTP ; GSA4098-9792, and -9793 (CSFM Listing No. 7300-0026:0217); *40989794 -9794T5P-9794TTP (CSFM Listing No. 7300-0026:0500). Models 4098-9714, -97141SP and -9714TTP are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:0220) and Models 4098-9755, -9755TSP and -9755TTP duct detector units (CSFM Listing No. 3240-0026:0241). Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division B®Simplex MAPNET Il® Communicating Devices UL, ULC, CSFM Listed, Zone Adapter Modules (ZAMs) FM Approved* Addressable Interface to Conventional Circuits Ik!I*1 MAPNET II ZAMs provide an addressable inteface to conventional fire alarm zone circuit devices** including: Initiating devices (Monitor ZAM) Notification appliance circuits (Signal ZAM) Control relays (Control ZAM) These ZAMs are compatible with the follDwing Simplex® fire alarm control panels when quipped with MAPNET II communications: 4100/4100U Series ire alarm c3ntrc1 panels 4100 Series Universal Transponders i/ 4120 Series Networl node fire alarm con:rol panels 4020 Series fire alarm control pands 2120 Communicating Device Transpondrs MAPNET II communications can be wired: NFPA Style 4/Class B or Style 6/Class A Style 4/Class B communications may bewi:ed either "T" tapped or In/Out Convenient DIP switch address selection UL listed to Standard 864 I -I ULi j nd iii Signal/Control ZAM Haim ip1 Le J ll Cu 0 -- [u ® \ I Monitor ZAM I'i*iF1ItT1 MAPNET II zone adater modules :ZAMs) provide an addressable interface between conventional zone devices and the host fire alarm con:rol panel. Monitor ZAMs provide status mcntoring and supervision of an initiating device ciccui; (IDC): zone and are used for circuits with non-addressable de:ectors and for other contact closures such as waterfiow and tamer switches or non-addressable manual stations. Different models of Monitor ZAMs are available for twcwire mCs Class B, or Class A, am for four-wire 0Cs with Class B mc input. Each type required a separate 24 VDC input power from a listed fire alarm power supply. Signal ZAMs supervise and operate 24 VDC notification appliances, speakers, and telephona circuits. Output capacity is up to 2 A @ 24 VDC, or 50W of 25 VRMS speakers, or up to three simultanecusly activatec firefighter phones. The signal ZAM is available for either Style Y/Class B or Style Z/Class A operation for notification appliance crcuits. * This product has been approved b' the California S:atv Fire Marshal (CSFM) pL'suant to Section 13144.1 of the California Health and Safety Cde, See CSFM listing 7300-0026:182 for allowable values and/or conditicis:concsrn ng matial presented in this document. It is subject to re-examnation, revision, and possible caicela:ior. ACditional listings may be applicable, contact your local Simplex prod'it vupplie/tor tire best status. Listings and approvals under Simplex Time Recorcor Co. ore the propery Cf —y,,o Safety Products Westminster. 1114-N iET(I7J7ffihi7IJ Control ZAMs provide addressable control functions such as elevator capture, HVAC control, pressurization fan control, and damper control. The control relay provides a DPDT contact (contact ratings are shown on page 4). General Specifications Commurications Supplied by MAPNET II 24 to 40 VDC with data Power Separate 24 VDC required from listed fire alarm power supply Wiring Information Refer to reference diagrams on pages 3 and 4 Wire Connections Screw terminals for ii/ot wiring, 18 to 12AWG wire Address Means DIP switch, 8 positioi Temperature Range 32° F to 120° F (0° C to 49° C) intended for indoor cperation HJmicity Range Up to 85% RH at 86° F (30° C) MAPNET I addressable communications are protected by U.S. Patent No. 4,796,025. S2190-0012-15 5/2010 Product Selection Zone Adapter Modules, Monitor ZAMs (separate 24 VDC power is required) Model Cover Type Description Supervisory Current Alarm Current 2190-9153 Surface Monitor ZAM, Class A (Style D) 2190-9154 Flush 20 mA @ 24 VDC 90 mA @ 24 VDC 2190-9155 Surface Monitor ZAM, Class B (Style B) 2190-9156 Flush 2190-9157 Surface 4-W ire Detector ZAM, Class B IDC input 2190-9158 Flush Zone Adapter Modules, Signal and Control ZAMs (separate 24 VDC power is required) Model Cover Type Description Supervisory Current Alarm Current 2190-9159 Surface Signal ZAM, Class A (Style Z) 15 mA @ 24 VDC 65 mA @ 24 VDC 2190-9160 Flush 2190-9161 Surface Signal ZAM, Class B (Style Y) 15 mA @ 24 VDC 2190-9162 Flush 40mA©24VDC 0163 Surface Control Relay ZAM, DPDT Contacts 10 mA @ 24 VDC 2190-9164 Flush Typical ZAM Mounting 4-11/16" (119 mm) Square box, 2-1/8" (54 mm) deep (Th çTh çTh / Typical ZAM assembly ( a C,(3 Z@ &— J oE40 0 fl (3 / 0 çmç/ 0 @5 4-11/16" (119 mm) 0 Square extension ring, 1-1/2' (54 mm) deep Flush cover, 5-7/16" square (138 mm) Surface cover, 4-15/16' square (125 mm) 2 S2190-0012-15 5/2010 Moni.or CiCL it 0- Resetaole 1-L, f1\ f_L\ End of line Detectcr rower L.) l) I.) relay 4- W re detector 2-Wire ionitor circuit. ZAM wiring + 24VDC - Monitor Class B, Style B "T" Tapped + MAPNETII ZAM 2-Wire monitor circuit or IN/OUT - wiring communications - Signal ZAM Wiring Reference 'T Tapped or IN/OUT wiring Class B/Style Y notification appliance circuit (speakers shown for reference) phone Class A/Style Z notification appliance circuit r phone 3 S2190-0012-15 52010 Control ZAM Reference Wiring Diagram Control ZAM _____________ - N.C.1 +_ 24 V DC - Common 1 —N.O.1 "T" Tapped or MAPNETII IN/OUT wiring communications -0— - N.C.2 Shield 0-0— Common 2 Controlled device NO.2 Control Power LiPT1P'I FV1 Th IDEAl '] ' £1TI Application Resistive Rating Inductive Rating** Power Limited* 2 A @ 28 VDC 1 A @ 28 VDC 2A@28VDC 1A@28VDC Non-Power Limited 1/2 A @ 120 VAC 1/2 A @ 120 VAC * DC Voltage must be from a listed Fire Alarm power supply ** Inductive loads must be properly suppressed. Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, the Simplex logo, and MAPNETII are trademarks of Tyco International Ltd. and its affiliates and are used under license. Simplex Tyco Safety Products Westminster• Westminster, MA 01441-0001 • USA S2190-0012-15 5/2010 www.tycosafetyproducts-usa-wm.com 0 2010 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 73000026:0182 Page 1 of 1 CATEGORY: 300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 2190-9146, -9147, *..9159 *..9160 Class A Signal ZAMs; 2190-9140, -9141, *..9161 * -9162 Class B Signal ZAMs; 2190-9138, -9139, *9157 *91584Wre Detector ZAMs; 2190-9144, -9145, *..9153 *..9154 Class A Monitor ZAMs; 2190-9136, -9137, *..9155 *..9156 Class B Monitor ZAMs; 2190-9142, -9143, *..9163 *..9164 Control ZAMs,; Models *4190.9050 -9051 4-20mA *monitor ZAMs; Models *21909169 and *21909170 line-powered MAPNET isolators. Refer to listee's data sheet for detailed oroduct description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as line-powered devices for use with MAPNET circuits of the follcwing control units: Model 4100 series (CSFM Listing No. 7165-0026.160), Model 2120-8018 (CSFM Listing No. 7165-0026.126) or Model 4020-8001 (CSFM Listing No. 7165-0026.17E). All devices are intended for indoor use only. *Rece 1017-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewea the test results and/or other data but does not, make an independent verificaticn of any claims. Ths listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructiors and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division ®Si m plEx TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSync Operation Compatible I1tuii*i Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens . Listed to UL 1971 and IJLC S526 Strobes provide synchronized flash for use with: Simplex® fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control 4009 IDNet NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Wall Mount Strobes Ceiling Mount Strobes cscrintic Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001-5 11/2014 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). F11v1iI.TI.1! I '(*I SmartSync two-wire control is available from: 4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more infDrrnation) 4009 IDNet NAC Extenders (refer to data theet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notifica:ion appliances include separate horns and combination horn/strobe notification appliances. dtmt Slttk Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing color "FIRE" Lettering Description 4906-9101 Red White 4906(9103) Wall White Red M:i-candela strobe with intensity selectable as: 1, 30, 75,01110 candela; synchronized flash rate: 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104 White Red Wall Mount Strobe Adapters Modet Description 'T Dimensions 4905-9937 Red Surface Mount Adapter Skirt use to cover 1-/2" (38 mm) 4905-9940 White deep surface mounted boxes Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 297-9145 bcx (typically for 8-5/16" x 5-3/4" x 0.060' Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Fiate 4905-9931 (200 mmx 130 mmx 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plaLed; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for addit:oial information) Model Description - - - - Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsJlated with 1-3/8" X 2-7/16" x 13 in/out 18 AWG (0.82 mm2 wire leads, ratec for 2 A NAC ' (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A oLtDut; mounts in 4" x 4-1/8" x 1-1/4" D 4(102mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards r Model Description * Dimensions 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H x 5" W 1-1,2" D For Wellmount strobes 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 49059961* Wall mount 6-1/16" H x 6-1/16" W 3-1/8" D Red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059926* Ceiling mount 6-1/8" x 4-3/8" x 2-7/8" deep (156mmx111 mmx73mm) * UL listed by Space Age Electronics Inc. 2 S4906-0001-5 1112014 Strobe Specifications - - Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (00 to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W 2-5/8" D (121 mm x75mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others Wiring access hole Wiring .terminals lllII -•_' (_Th__JTh 0 (fl Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only 75 from rear of housing; factory setting is 15 cd IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r —Electrical above bottom ii r box outline of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor yj Removable cover Strobe intensity (tool required) viewing slot S4906-0001-5 11/2014 Ceiling Mount Strobe Installation Reference ISingle gang box (Wiremold V5744S) 2-114" (57 mm) deep, supplied by others Handy box, 1-1/2" (38mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, req jired for 0 0j( surface mount with handy box unless using the 4905-9926 wire gua-d nt strobe 05-9926 wire guard :ing plate --------------- Strobe inlensty viewing sot ntensity selection plug, accessible only from rear of lens: lousing; factory setting is 15 cd i Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 45 lt1F-1h----1h1tfl I U OJO iI _________1 ]/ 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard 4905-9931 Adapter Plate (shown here for reference Only, can be used on other mounting options) Surface Mounting Reference with Optional Acapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mn) square I box profile, 1-1/2" (38 mm) deep Optional 4905-9961 I Wire Guard Strobe Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are providec on all four sides) TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use L; strictly prohibited. NFPA 72 a'tdVitional Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®s i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-000" USA , S4906-0001-5 11/2014 © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 c INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division fiSimplEx TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A operation when connected to the 4905-9938 SCM or with 4100U series fire alarm contro panel NACs Wall mount ANs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) UL listed to Standard 464 Pa" 71- 747": 1 _7 11 j T ff lit FIRE TI Wall and Ceiling Mount A/Vs Iiii.ii FFT1 Multi-Candela TrueAlert ANs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. 71 rIt1TU During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4906-0002-6 11/2014 I Strobe Arrnlic2tion Sc?IPr.tinn Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Svnhrnnizd Stroh--, Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. Ifriviii. r.urii SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." 4006, 4007E5 Hybrid, 4008, 4010, 40I0ES, 4I00ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color FIRE Lettering Description 4906-9127 Red White 906-9129 Wall White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9128 Ceiling Red White control 4906-9130 White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure sound level to ensure with 0.31" (8 mm) sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5" W 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 49059961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box (216 mmx156 mm x 76 mm) 49059928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc. S4906-0002-6 11/2014 2 AN Specifications Wall Mount or Ceiling Mount, Common Specifications UL Listed Rating Rated Voltage Range ULC Listed Rating Regulated 24 DC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm' to 3.31 mm2); two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage Ratings Sound Type (see Note 2) 16 VDC 24 VDC 33 VDC Steady Coded Steady Coded Steady Coded @ 10 ft (3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x 5" W 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mou nt Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 103 mA 196 mA 253 mA 50 mA 77 mA 147 mA 190 mA Housing Dimensions (with lens) 4-3/4 L" x 6-718" W 2-5/8" D (121 mm x 175 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 1, 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 76 mA 117 mA 222 mA 284 mA , 57 mA 88 mA 167 mA 213 mA NOTES: "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r —Electrical above bottom r box outline of compatible \ E boxes 1 ---T NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0002-6 11/2014 Mounting is compatible with single gang, double gang, and 4(102mm) square boxes, 1-1/2" (38 mm) deep, by others Optional 4905-9838 Sound Damper, field attached to attenuate sound 5 to 6 dBA Wiring access hole Wiring terminals for SmartSync operation I Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd Strobe intensity viewing slot Removable cover (tool required) 5-9145 Box 4905-9931 Adapter Plate 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Ceiling Mount AN and Guard Installation Reference I Ceiling reference, 4" (102 mm) square box, surface mounted box 1-1/2" (38 mm) minimum depth /( Ceiling reference, flush mounted boxV Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are p"located behind the housing LhA 1< Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side - Optional 4905-9927 Red Wire Guard End View ----------------------------------- Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (1102 mm) square box profile, 1-1/2" p (38 mm) deep Optional 4905-9961 Wire Guard .7 Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4906-0002-6 11/2014 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FCRESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHA'- FIRE ENGINEERING - EUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0317 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Eimplexloo Simplex Drive, Westminster, MA 0144-0001 - Ccntact: Jim Goyette (978) 731-8580 Fax -1978) 731-8881 Email: jamesgoyette@jci.com DESIGN: Models 4906-9127, 4906-9129 wall mountand Mod3ls 4906-9128 and 4906-9130: ceiling mount multi-candela horn/strobes. Refer to listee's cata sheet for detailed product description - and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installaton instructions, applicable codes and odinances, and in a manner acceptable to tie authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rat:ng, and UL label. APPROVAL: Listed as muti-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control modIe unless tie horn/strobes are used witl the listee's Model 410 (CSFM Listing No. *71650026:0226) 4100 (CSFM Listing No.7165-)026:0251) or *4007 (CSFM Listing No. 7165-0026:0378). Refer to listee's Installation Instruction Manual for details. *Rev J2-07-18 gt This lisJng is based upon technical data submittec by the applicant. CSFM Fire Engineering staff has reviewed the test resjlts and/or other data but dces not make an independent verification of any daims. This listing is not an endorsement or -ecommendation r of the item listed. This listiig should not be used to verify correct operational equiremenis or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Indoor Selectable- Output Low Frequency Sounders and Low Frequency Sounder Strobes System Sensor L-Series audible visible notification products are rich with features guaranteed to maximize profits with lower current draw and modern aesthetics. Features The [-Series offers the most versatile and easy-to-use line of low 520 Hz ± 10% square wave tone, NFPA compliance frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and Full candela range plus High/Low tone options to optimize current ceiling mounting, L-Series Low Frequency can meet virtually any draw for a wide variety of applications application requirement. Compact, standard, and round ceiling options Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Rotary switch for High and Low, Temp3 and Temp4 settings Plug-in design with minimal intrusion into the back box Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices (Direct replacement for HW/R-LF and P2R/WH-LF) Compatible with MDL3 sync module Sounders listed for ceiling and wall mounting Sounder Strobe listed for wall mounting Updated modern aesthetics Agency Listings SIGNALING @ <~> 0 LISTED APPROVW S4011 PR452768 Horns only: 7135-1653:0516 Horn/Strobes: 7125-1653:0517 The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire L-Series product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, [-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, 24- volt operation, and a rotary switch for 520 Hz low frequency sounder tones. AVDS910.01 • 10/1/2079 • Page 1 L-Series Specifications General L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terrrinate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit (0°C to 49°C)frcm a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings: including 15, 30, 75, 95, 110, 135, 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads "low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor L-Series Model listed to UL 464 and shall be approved for tire protective service. The low frequency sounder and the Sync'CircuitTM MDL3 Module accessory, f used, shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts (includes fire alarm panels with built-in sync). When used with the Sync.Circuit Module MDL3, 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non- temporal (continuous) pattern and coded supply within the frequency range of 520Hz .± 10% square wave tone. The low frequency souncer shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approvea for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with ths Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage raiçe. The strobe light shall consist of a xenon flash tube and associated lens/reflector syste'n. The sounder shall have an option to switch betwser a temporal three or temporal four pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-c ded power supply with high and low volume settings. The field selectable tones will sound within the frequency range of 520 Hz ±10% squzre wave tone. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal ihree. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 41111€ x 411/1€ x 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range .. 520 Hz± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 24 DC/F\NR Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12to18AWG Dimensions Wall Sounder Strobe (including lens) - 5.6" Lx 4.7W x 1.9" D (1 42 mm Lx 119 mm W x 49 mm D) Standard WallSounder ' 5.6"Lx4.7"Wx 1.5" D(142mmLx 119 mm W x 38 mm D) Compact Wall Sounder 5.25" Lx3.46"Wx 1.5" D(133mm Lx88mmWx38mm D) Ceiling Sounder 6.8" diameter x 1.4" high (173mm diameter x 36mm high) Standard Wall Sounder with SBBRL/SBBWL Surfaêe 5.7" Lx 4.8" W x 3.3" C Mount Back Box (145 mm Lx 120 mm W x 87 mm D) Compact Wall Sounder with SBBGRL/SBBGWL Surface 5.4" Lx 3.6" W x 3.0" IJ (137 mmL x 91 mm W x 76 mm D) Mount Back Box Low Frequency Ceiling Sounder with SBBCRLISBBCWL 6.9" diameter x 3.9" high (175mm diameter x 99mm high) Surface Mount Back Box Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source taat is used on some power supply and panel outpLts. AVDS910-01 1O/112019 -Page 2 UL Current Draw and Sound Output Data Sound Current Draw (mA) Output P Volume 1 1633VDC 1 16-33 FWR 1 16-33 V Pos Tone Settina I ici nrind 79M QcrrI 11flrd ic-rI 1gc-rI I 18;rrI ni 79;M acM 11fl,rI 1 9;M 1rrl I fl( FW 1 Temporal High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal 3 Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal 4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 285 165 182 226 244 266 297 342 76 76 UiU Pos Low IFrequency Tone Volume Setting Sounder Current Draw Current Draw 'mA' flWI;li'di Sound Output (dBA) Reverberant 16-33 Volts 16-33 Volts DC FWR DC FWR 1 (Lemporl 3) Hgl 108 150 00 2 Temporal 3 Low 78 76 76 76 3 Temporal 4 High 111 151 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 1 76 76 76 NU I h: F-or coded tones, temporal coding must tje provided oy trie NAC. If the NAC voltage is held constant, the sounder output will remain constantly on. Coded ratings provided are for continuous voltage. AVDS910-01 • 10/1/2019 • Page 3 L-Series Dimensions II Ii iii ii I iii I .iPii ' 1111 Wall LF Sounder Strobe Wall LF Sounder 1.4 3.455 453 5.265 Compact Wall LF Sounder Ceiling LF Sounder Red White Low Frequency Sounder Strobes P2RL-LF P2WL-LF LF Souncer S:robe, Wall Low Frequency Sounders HRL-LF HWL-LFJ [F Sounder, Wall HGRL-LF HGWL-LF Compact _F Sounder, Wall HCRL-LF HCWL-LF LF Sounder, Celing Accessories 1 MDL3R MDL3W SynceCircuitM rodule, UL-isted SBBRL SBBWL Surface f:oLnt Back Box, V\all SBBCRL SBBCWL Surface Mount Back Box, Ceiling SBBGRL SBBGWL Surface Mount Eack Box, Wall, Compact System Sensor® is regisrred iadernark and Sync.circuitms is iztradmark of Honeywell i terrotisn.sl, Inc. .SYS TEll/i 3825 Ohio Avenue • St. Charles, •L 60174 ©2019 Sbsterr. Sennor. Product speci ications subject to change rrAgrout notice. Visit systemsensor.com SENSOR" Phor.e: 600-SENSOR2 9 Fax: 630-377-6495 tio AVDSSIo.ol • ID/t/2019 for current p duct informan, including tihe atost version of this data she l a CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0516 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models HRL-LF, HWL-LF, HCRL-LF, HCWL-LF, HGRL-LF and HGWL-LF are low frequency horns. Horn models HRL-LF, HWL-LF, HGRL-LF and HGWL-LF may be mounted on the wall and are intended for indoor use only unless otherwise indicated. Horn models HCRL-LF, HCWL-LF may be mounted on the ceiling and are intended for indoor use only unless otherwise indicated. The standard horn models are the HRL-LF, HCRL-LF (red enclosure) and HWL-LF, HCWL-LF (white enclosure). The horn has an 8 position selectable tone settings. Models HGRL-LF and HGWL-LF perform the same as HRL-LFIHWL-LF and use a "compact" housing which is intended to mount to a single gang electrical box. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: The models HRL-LF, HW-LF, HCRL-LF, HRWL-LF, HGRL-LF and HGWL-LF are rated 16-33 VdCNFWR (REGULATED 24 DC/FWR). INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, audibility ratings and UL label APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 07-01-19 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 02, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division S. Johnson 0)1v- Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com .4 Contractor's License Detail for License # 986047 I Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 4)5-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2021 This license is current and active. All information below should be reviewed. C10 - ELECTRICAL C16 -FIRE PROTECTION CONTRACTOR Contractors Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Quahfyingdividual This license filed Bond of QaIifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82520648 for JOSEPH ANTHONY FEDDELER in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 07/26/20180 I Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC313943 Effective Date: 10/01/2018 Expire Date: 10/01/2020 Workers' Compensation History Other I Personnel listed on this license (current or disassociated) are listed on other licenses. I 10/11/2019 REV.#: 0 PROJECT #: 480- k Johnson dow Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com JOHNSON CONTROLS WARRANTY WARRANTY & DAMAGES: Johnson Controls hereby warranties for one (1) year from the date of beneficial use or twelve (12) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. Johnson Controls shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by Johnson Controls in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED JOHNSON CONTROLS HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 2/7/2019 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXXXXXXX