Loading...
HomeMy WebLinkAbout2665 CAZADERO DR; ; FPR2019-0170; Permit4., PERMIT REPORT city of C arlsbad Print Date: 02/22/2021 Job Address: 2665 CAZADERO DR, CARLSBAD, CA Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2154600200 Track #: Valuation: $564,657.00 Lot #: Occupancy Group: - Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2019-0170 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 08/29/2019 Issued: 09/23/2019 DEV2016-0001 Finaled Close Out: 11/22/2019 Inspector: Final Inspection: Project Title: MANANTAN RESIDENCE Description: MANANTAN RESIDENCE -NEW 13D SPRINKLER SYSTEM (49 HEADS) Applicant: FPContractor: INNOVATIVE FIRE PROTECTION INC INNOVATIVE FIRE PROTECTION INC JOSEPH PLASSMEYER . 8779 COTTONWOOD AVE, # STE 101 8779 COTTONWOOD AVE, # STE 101 SANTEE, CA 92071-4457 SANTEE, CA 92071-4457 (619) 593-8200 (619) 593-8200 FEE . AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) . $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665.1 760-602-8561 f I www.carlsbadca.gov INNOVATIVE FIRE PROTECTION,INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR MANANTAN RESIDENCE 2665 CAZADERO DRIVE CARLSBAD, CA 92009 FILE NUMBER: C7514 DATE: AUGUST 27, 2019 -DESIGN DATA- ffp' ~_o I I -01+0 OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ BOR) SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: RESIDENTIAL/LIGHT .05 gpm/sq. ft. 169 sq. ft. (BED #3) 20' X 20'-400 sq. ft. 1 sprinkler 21.0 gpm 26.0 gpm 21.0 gpm 8 45.1 psi 7/16 inch INNOVATIVE FIRE PROTECTION, INC. JOE PLASSMEYER CARLSBAD FIRE DEPARTMENT C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # &CLICE& HRS SYSTEMS, INC. H Q Q U) U) 0 c-i 0 U) U) ci) 4J.0 En 4J U) (U 4J 0 U) -d a) 4J E-4 0 ow ti-i H U) (U U) U) -1 4J (U U) a) U) 0 4J 34 r-i a ° (o "o rm 4J U) )< (U li-i 4) c-c (U (U 0 ri (I) -Ow c-c U) U) U) U) U) -H Q U) -d4J U) •r1 U) U) (U 00 -i N U) -c-i 0 z SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 8/26/2019:\USERS\JOEP\DESKTOP\HASS DATA\MANANTAN RESIDENCE(1HD) .SDF JOB TITLE: MANANTAN RESIDENCE 0 0 0 0 0 0 0 0 • • • • 0 N 0 0 0 0 0 • H H H 00 0 w0Ocr1 cr1C/)U)0cr1 —QU)-H--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/26/2019:\USERS\JOEP\DESKTOP\HASS DATA\MANANTAN RESIDENCE(1HD) .SDF JOB TITLE: MANANTAN RESIDENCE NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 107.0 90.0 500.0 106.9 26.0 68.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 435.0 SOURCE 68.7 26.0 2 435.0 - - - - 65.7 - - - 2A 435.0 - - - - 62.7 - - - D 435.0 - - - - 62.4 C 435.0 - - - - 56.9 - - - 3A 449.0 - - - - 49.4 - - - 313 451.0 HOSE STREAM 46.5 5.0 3 453.0 - - - - 45.1 - - - 4 455.0 - - - - 44.0 - - - 4A 455.0 - - - - 40.0 - - - 5 459.0 - - - - 31.4 - - - 6 459.0 - - - - 30.7 - - - 7 459.0 - - - - 26.4 - - - 8 459.0 - - - - 26.4 - - - 9 470.0 - - - - 25.2 - - - 10 470.0 - - - - 22.0 - - - 11 470.0 - - - - 19.7 - - - 12 470.0 - - - - 20.1 - - - 101 470.0 - - - - 22.0 - - - 102 470.0 - - - - 22.0 - - - 103 470.0 K= 4.90 18.4 21.0 104 459.0 - - - - 26.4 - - - 105 459.0 - - - - 26.4 - - - 900 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/26/2019:\USERS\JOEP\DESKTOP\HASS DATA\MANANTAN RESIDENCE(1HD) .SDF JOB TITLE: MANANTAN RESIDENCE NFPA3 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) To Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) Frm Node El (ft) PT Tot. (Q) Disch Act. ID (ft.) T Pf!ft. (Pf) Pipe: 1 0.0 0.0 10.00 150 65.7 2 435.0 65.7 26.0 2A K1.000 T: 6.0 7.00 0.0 1 435.0 68.7 26.0 0.995 G: 1.0 17.00 0.181 3.1 Pipe: 2 0.0 Fixed Pressure Loss Device 2A 435.0 62.7 26.0 D 3.0 psi, 26.0 gpm 2 435.0 65.7 26.0 Pipe: 3 0.0 0.0 2.00 150 62.4 D 435.0 62.4 26.0 C L1.000 ---- 0.00 0.0 2A 435.0 62.7 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Pressure Loss Device C 435.0 56.9 26.0 3A 5.5 psi, 26.0 gpm D 435.0 62.4 26.0 Pipe: 5 0.0 0.0 60.00 150 49.4 3A 449.0 49.4 26.0 3B E1.610 3E:18.1 18.13 6.1 C 435.0 56.9 26.0 1.610 78.13 0.017 1.4 Pipe: 6 H.S. 5.0 Disch 3.00 150 46.5 3B 451.0 46.5 21.0 3 L1.000 E: 3.0 10.00 0.9 3A 449.0 49.4 26.0 1.025 T: 7.0 13.00 0.157 2.0 Pipe: 7 0.0 0.0 2.00 150 45.1 3 453.0 45.1 21.0 4 J1.000 E: 5.0 5.00 0.9 3B 451.0 46.5 21.0 1.101 7.00 0.074 0.5 Pipe: 8 0.0 0.0 2.00 120 44.0 4 455.0 44.0 21.0 4A A1.000 ---- 0.00 0.9 3 453.0 45.1 21.0 1.049 2.00 0.142 0.3 Pipe: 9 0.0 Fixed Pressure Loss Device 4A 455.0 40.0 21.0 5 4.0 psi, 21.0 gpm 4 455.0 44.0 21.0 Pipe: 10 . 0.0 11.2 7 57.00 150 31.4 5 459.0 31.4 9.8 6 J1.000 2E:10.0 35.00 1.7 4A 455.0 40.0 21.0 1.101 5T:25.0 92.00 0.074 6.8 Pipe: 11 0.0 0.0 5.00 150 30.7 6 459.0 30.7 9.8 9 JO.750 E: 4.0 7.00 0.0 5 459.0 31.4 9.8 0.874 T: 3.0 12.00 0.056 0.7 Pipe: 12 0.0 0.0 11.00 150 25.2 9 470.0 25.2 9.8 10 JO.750 T: 3.0 3.00 4.8 6 459.0 30.7 9.8 0.874 14.00 0.056 0.8 Notes SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/26/2019:\U5ERS\JOEp\DE5KTQp\j-j55 DATA\MANANTAN RESIDENCE(1HD) .SDF JOB TITLE: MANANTAN RESIDENCE Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) To Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) Notes Frm Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pflft. (Pf) Pipe: 13 0.0 0.0 8 67.00 150 26.4 7 459.0 26.4 11.2 12 JO.750 T: 3.0 3.00 0.0 5 459.0 31.4 11.2 0.874 70.00 0.071 5.0 Pipe: 14 0.0 0.0 14.00 150 20.1 12 470.0 20.1 11.2 11 JO.750 2E: 8.0 8.00 4.8 7 459.0 26.4 11.2 0.874 22.00 0.071 1.6 Pipe: 15 0.0 0.0 27.00 150 26.4 8 459.0 26.4 0.0 JO.750 2T: 6.0 6.00 0.0 7 459.0 26.4 0.0 0.874 33.00 0.000 0.0 Pipe: 16 0.0 0.0 5.50 150 26.4 104 459.0 26.4 0.0 JO.750 E: 4.0 4.00 0.0 8 459.0 26.4 0.0 0.874 9.50 0.000 0.0 Pipe: 17 0.0 0.0 5.50 150 26.4 105 459.0 26.4 0.0 JO.750 E: 4.0 4.00 0.0 8 459.0 26.4 0.0 0.874 9.50 0.000 0.0 Pipe: 18 0.0 0.0 48.00 150 22.0 10 470.0 22.0 9.8 11 JO.750 3T: 9.0 9.00 0.0 9 470.0 25.2 9.8 0.874 57.00 0.056 3.2 Pipe: 19 0.0 0.0 7.00 150 22.0 10 470.0 22.0 0.0 JO.750 E: 4.0 4.00 0.0 101 470.0 22.0 0.0 0.874 11.00 0.000 0.0 Pipe: 20 0.0 0.0 7.00 150 22.0 10 470.0 22.0 0.0 JO.750 E: 4.0 4.00 0.0 102 470.0 22.0 0.0 0.874 11.00 0.000 0.0 Pipe: 21 0.0 21.0 103 33.00 150 19.7 11 470.0 19.7 -11.2 12 JO.750 E: 4.0 7.00 0.0 10 470.0 22.0 9.8 0.874 T: 3.0 40.00 0.056 2.2 Pipe: 22 4.90 21.0 Disch 2.00 150 18.4 103 470.0 18.4 0.0 JO.750 E: 4.0 4.00 0.0 11 470.0 19.7 21.0 0.874 6.00 0.229 1.4 Pipe: 23 0.0 21.0 103 4.50 150 19..7 11 470..0 19.7 -9.8 10 JO.750 ---- 0.00 0.0 12 470.0 20.1 11.2 0.874 4.50 0.071 0.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 8/26/2019:\USERS\JOEp\DESK'roP\HASS DATA\MANANTAN RESIDENCE(1HD) .SDF JOB TITLE: MANANTAN RESIDENCE NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.015 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 11.2 ft/sec at pipe 22. Items listed in bold print on the cover sheet are automatically transferred from the calculation report., PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEl1 ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee -------------------------------------------------------- F45E11 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 2.00 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NTee -------------------------------------------------------- F45Eil 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 1.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 8/26/2019:\USERS\JOEp\DE5KTOp\HASS DATA\MANANTAN RESIDENCE(1HD) .SDF JOB TITLE: MANANTAN RESIDENCE PAGE: J MATERIAL: CPVC Tyco/NFPA HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVlv Gate 0.874 1.00 4.00 3.00 1.00 1.00 5.00 0.40 1.101 1.00 5.00 5.00 1.00 1.00 8.00 0.40 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45 -Ell TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45 -Ell TeeRun Kouplg ChkVlv GatVlv NPTee 1.025 3.00 7.00 1.00 2.00 0.00 7.00 0.00 7.00 We 11141N) PrymnT Was At pki in Wwr Him Meter Siac (in.) l$or less (118) 23 071 26 (68) St (III) 36 (148) li,6 Imi'S I.) (ft:'T mi 1 :2 h,r 1264).s (Eli ss '2,4 .': ',(20 mm) 7 i1,-;$ 0;,i'i I I (lS,7 I,,,) (' It :4 (mr 'i l S (:5': 15 ('2') I (25 mm) CO. 14 l>:ir) :1, (ii '21 hi') (42) boo'1'(i.'$ (LIII 6 (05) h:e'; Ii) 1414) i') )(40 nm) ).U7 h:ir) I 0107 hail 2 (6,11 !-!:it-) 2 io .!-i 6:1 1 (04(4 mi' 7 I '64 Iit') 2 (50 nut) I (((.1)7 bar) 1 0(.07 hai'i I fti)7 h:ui ) 1 iO.6 h:,r 2 ((1,1.4 lit) :4 1(1:21 hi') I gJIII i.71i:, .,'i'i,i,i: I Ill. = '_'.I flax iiiiiii :lled (I) The S"/R:i'li )lrr,r' I':,l, sl:tll Ii's lflhli hid fl at With Sc tiii- IC).) an d 1)2,:i'rl ii shall be mleit'i'm'mijni'il t hat tiii' flov. lll(ifl't'(I Is' the '''acer ui,:u'i' ia 'iL'. ri' ex'eC'iis we s'51eml) ctemii:,,i(( aild that ilie liii:,) iii'::s:imi lioi' (lflCz 1()1 i'Xi,'i'i:'(i tb: fli1Nlll)1111) ('Iii'" ;,iliiss''rl h the pipit'li 5\'/li'll) (;(ll)(()i')ileli 5. FIll' i'31(fi' I)'eS.sti'e ill ilim' sii' e,' .sliail iii' uli'l't')'ilmli(t'd. Pipe sizes sitt1l lie selected. 4)( Prcssui'c loss For :1 i'aiCi' flu,fli,:i' II' :161 5)1:111 be du'6';'- 11116CC1 :'iru,l cie(iticic'd IiSjfl' iiimc 'ii liii:' l'i,iili,,r'in: (a) 16l))C 10."i,'i):)) shall he '),:I'i'liiliCi'l sr hi' t151,'i'i, ('Sill il'tt','e ilti: Spl'il)kfel' (lenl:lild fIns' exi.u':'(s 0i I'a)C(l ',1iil jill lullS II me, (0) l-llgllr'i' pi'c'.s.siii'e ll,S,si',S .s,ec:iliei.i 1'' Iii' liLlilIWie- illi'cl' 5)1:111 be list',,1 in plate i>l 411(141 Spetdu'(( in 'l'ahle I I),') '1 (a (c) Li,am'ci' pl'eSSiIl'C: iii,si's shall he pci'niiiierl to 'il' Isl'd '1'i(t'l'L' s1lf)')uai'ulilg tla a ii',' :ii'cis'icli:cl I'll' thr illolcr (3) Prci,ii'e hiss liii' ell::'':lljiiil sh:iIl Ii'' licc,li,R'u'd :0 i'iil(iifl's: al l)tti(cln6 iu'ii,hii :ihs'' s(rt'i:'c (('i) a (),-1'3 = :,uc,sslll'e has (psi) (Ii) P,iijl(lji1 Sl,)i'i: be (lIe) ((oS Pi'essui'e ii)s5cs ii'l:illl tilt: ('i)v iil:llil Iii ili,: iiiz.ide' Ci.l'itl'I,Ii valve shall 1C C!i:(,lilcieti l)\' I1liilllpl\'lllC' (lu' pi'i.'55IIl'1' (('"S :issc.u('i:ilcri \s'(l Il tIme ill.)(: 11:11 1:11:11 )av III— Ii ri:,l OF pipe in I:i,,' (iiii'i,&:i's) (7) Pressure hiss for pptiii' m'Iihtii the hiljldtl'it sheili hi' dcd,mcit'd be riiiliip:v:t'ig rue pI'essui'e lios:is,'uelale(I i/tIll hi' p1(11' ii(Il1'i'i:,1I fm 11u, loml lelu.I'ihl,$) ml ).ii' il ('eel (nictei's) ((S) Pi'i:'suit'm' lu-is liii' vak'm's :iiiii tiuui'i'4's sii:Ill iii: cl-ili,eii'i'l is lol l(ui's: (a) t'iie ',di'es aiai'i iiiiii'uts l'i'un lie" u'i'u,'uim'uul s':•ds',: lu ihi' hii'dicsi 51')u'ii)klu:1' ,m)iail b1' Clii! iied. (1)) Thc ('9111\'aiCl'll. leiiiii'i l'i,i' i';uc'hi s:',lvu: acid Zis lioss'ii (ii 'i:min(i' (0,4,4(h), 'bililc l6,-I.-i(c). lab),' mi '11h1e 10A1(e) shall he uleterrniiaecl :,ii(i IIIC s'almm's ;iuiu'h'il to iii aln ihe li'il.al C((lli\'illt'ilt Icliglil Cia:' i":icli pipi:' size. 0 iii' c'ifiii\';.!ls'iil tiziii01 for cacti Si/C shall be nlii)ia- lU'Cl by Or piessuii'i' loss :issociatcct with (lie pip,' 'i Ci cii:,) and I tic i'atiics totatec,I. In i)lIli(il&a'C'I I'i1i(i(Iifls, il'i(: steps in 10,4.4(1) thrutigh 111(415) sl'i..til be 'epi:;iter.l (U Si/C piping for each I'lnoi'. i.1111 hi Ilic I'(:iilaiilliii( p'cssuui'l: is II.'SS Mail ihc: o1lei'atiilg pi'Cs- Stile c'stahlislnt'i'i 1w or iu''sijrit t:il:iti':iioi'' I'uiu' thC' spiari_ kh'i' i)i:im()' tlsvd. L(i: sprinkler .c''.Slelil shalt hi: i',:i'1ia5113i , 1(1. I) II' lilt: i'eiliaIiitllt pi'15Sii('C (5 l'iiihei' Ilialu ix''C(Uul'ecl, smaller tilpint)' sli:uii he ici'ii'iitied (U be used ('(eel h%. ('61(3 i1i II',)iiS. (('2) The i'Ci'iflulili!'lg piping shall (Sc su'iCCl We 'time' as the (,ui(')111i4' lu(,) Iii :sncl iiactiitliia.,' (lit' 1111'lhcSl spi'inklei' uii'ihes SIi'i4ille'l'pipr' sizes ui'i_')iis)ihc('t hsctulciilaiiois. 10.1.5 To Si/(' pi0ii114 For SV.41'ii'us %\'iLli in etevaiCd lank. PufliP. or pltmf)—)aiik t'l,iiahiit,ii ((111. )Ilu pu'esSui'c :u tlii: waii,:u' supple tiumlem sli:i(I lii,: cleicl'(uuli',(:d mid Ill: seeps in 10.''i.-t'(S). ç4-). (7). (8) (') (il)) turd lh)slililh)('h')ll(ifi'ed. ill.'l.h l'i\'ill'allhic 11'ilC'tll!6011 )rl'c't(hiii'CS in :,eci)l'(haiiC(' lejlla :n,.Fl,l,,\ 1'1, shall lii: 1l1t'lI fir t)'i'i(i'Ivf1t' 4\'Siefli, 0.4.7 'iv,'! 'anilu' ih'il,uIii'>i'u n'i)CC(huli'CS Ill (ii.'eu)t'(i'dl'it'C' with I sl'i:ill I:,.' user1 'ii' iuuiipi'il-ivpe S\'511211'IS, I ()-1.8 I"I'clr:ai lit: c:,ictil:it iii pl'urccclul'es it) :,ccnial:tiice X 'u.\ i 4)1:111 hi: toil hr ss'sieiils connccid In Cli" fi':il.Ci Ii:s:sIl,:tli_(ili,U01i'u1}1't)1iidi4fuut,'1Ci, Pipe Si'i.uag (eteihocl, Pipe sh:'ill he si'ied b di'lerlaliiliiit) the ,is':'uiIIiIu'' pi'u7ssuiCC El iil'lsei ti'lt'htu(l loss it )aij)iui)(6llC) idi:inll'4ilit)' a 'ilpint) niaum-riah. (hialiiel.c'r, :16(1 iengd Usilill' lie, l:'i)uiiil,rli ha 1(1:1(1) and 11i' 1uu'ücturt' ii 104.9.2. ['able 04.4(h) (`.quiv'aiciiu Leiigthi in ("cc) of Fleliiii)s and V:ilve for Schii:ctti.he 40 Steel Pipe l,t,i. )',''.'ui' I)i.uiuieicr 4301g1,- 30 l)-gi'unu' ii:ucliuus (II u' iulu'uiecl sui':uuelu Pnuiieriu 10 1 i'5ru:''s I Ill i'luuu 0.1 Cue \':ib'i' .'\1i5)C \",ulu'uu C lobe \'a (vu, \i.i),..t Cock Vds in Check ViJu I ))fi ituni) I 1)1,4 ml) 6,,; liii ''illi 1,14 n " i:ni i 7 1 iii '34 ,,) IS 'L ii ii) 'I l,7 ii4 Fu (1.5 iii' I 'i3 iii I I alt A 3 ii i iii, 2 Ii i 6M II KnA ms WA IN CID Iii) i I uu I 1 I ni I (tOni )i( I U I (I 1 1 iii I I I It )S I ii I ill I ill (u(I ill i 2(40 innil C (uiil ut 500, '('(IOu 'ii n I .,.., a ui..,: I i': il .." "147 :t 111) -" .- .17 )I7.'I II) -.--- s is.S ui - 7(2,1 nit )( 3,41 vu-St linits. I r,i, in '23 11i): I It me I) :1 il 20115 Edit ZURN Model 950XL WILKINS Double Check Valve Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/4"-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern Cali- fornia (vertical 3/4") City of Los Angeles Approved (vertical 1-1/42) 'NYC MEA 426-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 3/4, 1, 1 1/2, 2 Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure - 350 PSI End connections Threaded ANSI B1.20.1 Options (Suffixes can be combined) E - with full port QT ball valves (standard) E L - less ball valves U - with union ball valves S - with bronze "V type strainer TCU - with test cocks vertical up O V - with union swivel elbows (3/4" & 1") 0 OSY - with OS & V gate valves O FDC - with fire hydrant connection (2" only) O FT - with integral male 45° flare SAE test fitting PF - with ZBiteTM push fit connections* (1/2-1 only) PR - with ZPressTM press fit connections* *Fittings ship in box with valve and must be threaded into valve by hand on site. Accessories E Repair kit (rubber only) Thermal expansion tank (Model XT) 0 QT-SET Quick Test Fitting Set Dimensions & Weights (do not include pkg.) DIME NSIONS_(a proximate) WEIGHT MODEL A UNION LESS WITH SIZE A BALL 0 LL.,) BALL C D E F G BALL BALL VALVES VALVES VALVES VALVES in. mm in. mm in. Imm in. Imm in. mm in. mm in. mm in. mm in. mm lbs I kq lbs. 3/4 20 111/4 286 121/2 318 7 178 11/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 3.2 1 25 121/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 451 12 5.4 11/4* 32 151/2419 181/2 470 109/16 268 2 51 31/2 89 4 1/2 114 4 1/2 114 211/2 546 813.6 22 10 11/2 40 171/8 435 191/8 486 109/16 268 2 513 1/2 89 41/2 114 41/2 114 223/4 578 E7.3 22 10 2 50 181/4 460 20 508 10 9/16 268 2 51 31/2 89 41/2 114 41/2 114 25 1/8 638 7.3 28 12.7 *Size 1-1/4 Discontinued Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. 0 Date: 4/15 Document No. BF-950XL Product No. Model 950XL www.zurn.com I Page 1 of 2 C,15 Co 0. Flow Characteristics 0 Rated Flow (established by approval agencies) MODEL 950XL 3/4", 1°, 1 1/4", 11/2" & 2" (STANDARD & METRIC) FLOW RATES (us) °- 0 20 40 60 80 Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. gj' .1' 1. I S [si, 1.1' sI' 4. Capacity thruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 in 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 1 63 1 95 2" 52 78 1 105 1 167 FLOW RATES (GPM) 12' MIN 30" MAX ." ......... . - . - DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION Specifications The Double Check Valve Backf low Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ba l l v a l v e s . The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NS F ® L i s t e d NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for main t e n a n c e w i t h - out removing the device from the line. The Double Check Valve Backflow Preventer shall be a ZURN WILKINS M o d e l 9 5 0 X L . Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC RESI-RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESl-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 11/4", 1W', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent U 6,076,545 RESI-RISERTM Size Chart Description 1" 11'" F/a" 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2" Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve 0 National Fire Products, LLC (800) 528-7978 Pressure Loss Tables• Pressure Loss in 1" Resi-Riser 12 Relieving Pressure Exceeding 175 psi R i 4 Manual Open - Drain :r Flow Switch Test Locked Closed for Hydrostatic Test - 10 CL 8 w '-6 2 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser 10 J --- I eof 4 fA IA 2 EitIIIII 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Pressure Loss in 1-1/2" Resi-Riser 10 1 1 1 1 1 1 I I I I I I I 0 10 15 20 25 30 35 4045 50 55 60 65 70 75 80 Flow (gpm) Pressure Loss in 2" Resi-Riser ------------------p i•iuu•iuiuuuiisi IIIIIIUlUIIIR!1lUI uui..mugu.iuui.rn IUIPUm1lIIIlIIUI I :;imiuI•aIuIuuiuui s 4 I .1 Pressure Relief/Test and Drain How it Works Normal Position - tatic Pressure © National Fire Products, LLC (800) 528-7978 1 or u SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: 5S8464 -- GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No.U085165 Date . Jan/11/2019 TECHNICAL DATA Approvals: cULus Listed, NSF-61 -G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K4.9 GPM/psi"' (70.6 LPM/bar112) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (720C): Uncolored 175°F (79°C): White Color Code (Cover Plate) 140°F (600C): No Mark 162°F (720C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1-1 Page 2 of 8 2-06" 16" Lot No. [ Year of Manufacture SIN 5S8464 - -K-factor: : K4.9 I Temperature Rating: 162F/72c or I75F/19c 1-UL Mark rcontrot No.: 6P37 [NSF Mark: NSF-61-G _H RES SPKR ® Body (Copper Alloy) ® Deflector (Phosphorus Bronze) (3) Gasket (PTFE) (68mm) ® Fusible Metal (Solder) or 3-I/4 (83mm) (5) Heat Collector (Copper) or 2-518"souare (068 mm) () Cover Plate Assembly FIGURE 1. Model RC-RES K=4.9 ,-- ng: COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) Normal Condition Cover Plato Operation Sprinkler Operation Water Discharge - FIGURE 2. OPERATION PROCESS (The figure is for illustrative purposes only) Document No. U085165 Date . Jan/11/2019 Page . 3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, if is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 130 and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 130, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Document No. U085165 Date Jan/11/2019 Page . 4 of 8 Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLEA. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model S58464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Intermediate Maximum Maximum Temperature Rating Temperature Rating Minimum Coverage Area Spacing 162°F (72°C) 175°F (79°C) Deflector Installation Spacing Ft. x Ft. Ft. to Ceiling Type Ft. Flow Pressure Flow Pressure (mxm) (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) 12x12 12 13 7.0 13 7.0 (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) Smooth Ceilings 14X14 14 13 7.0 13 7.0 3/8to7/8 (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Inches. Beamed 15x15 15 13 7.0 13 7.0 (4.6x4.6) (4.6) (49.2) (0.48) (49.2) (0.48) Ceilings per NFPA 13D, 13R Concealed 8 (2.4) 16x16 16 13 7.0 14 8.2 or13 (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) Installed in beam 3/8 to 7/8 18x18 18 17 12.0 18 13.5 inches (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) below bottom of beam. 20x20 20 21 18.4 (6.1x6.1) (6.1) (79.5) (1.27) - - For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) Document No. U085165 Date . Jan/11/2019 Page 5 of 8 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of to 14 ftlbs (9.5 to 19.0 N.m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8" drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the 'Vertical Adjustment" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Do Not Over-Tighten Ave. 1 /8" (32 ) /4" (6.4mm) 1 Make a Space Hero kGroove on the Sprinkler _ otective Cap _ vertical Aduetment ml Tooth on the Socket 6 kSoctkot HR-Hw Mounting Surface Mounting 2-3/8 ( 60mm)Ratchet SuaceCeiling Hole 0iamcter IcORRECT L FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Document No. U085165 Date . Jan/11/2019 Page 6 of Sprinkler Head Hook up :Ct vecauji Cap Remover PC I Pull down Step I Step 2 Step 3 FIGURE 5. PROTECTIVE CAP REMOVAL - E E 0 04 4 - Cover Plate Assembly or 3-1/4 (83mm) or 2-5/8"square (068wm) FIGURE 6. INSTALLATION (COVER PLATE ASSEMBLY) FINCORRECT I ICORRECT I I INCORRECT I FIGURE 7. INSTALLATION (CORRECT and INCORRECT) Document No.U085165 Date Jan/11/2019 Page 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F/40C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Mode! RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under TABLE A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. it is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No.U085165 Date Jan/11/2019 Page .' 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C)) Cover Plate Assembly 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes. temDerature. and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F o o - - - - - - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F o - - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - - 0 0 Tools for Installation of Model RC-RES Socket NR-H For use with a 3/8" drive ratchet (not included) Socket NR-H Plastic For use with a 1/2" drive ratchet (not included) Cap Remover RC Document No. U085165 Date Jan/11/2019 Bulletin 135 May 2019 Relmiabi Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The FiRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D, The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 130. For NFPA 13R and NFPA 130 applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin:Model Fl Res Series sprinklers are listed for use in wet systems only. Residential Sprinkler Summary Sprinkler Sprinkler Identification Orientation K-Factor gpm/psi112 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (Ipm/bar1 ) NPTorlSO7-1 ftxft(mxm) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14 x 14 (4.3 x 4.3) F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res76CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed or 20x20(6.1 x6.i) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) www.reliablesprinkler.com Face of fitting to finished ceiling 5/8" (16mm) +1- 3/8" (9mm) 1-1/4" (32mm) Dimensions Fl Recessed Escutcheon Installation Face Face of fitting to finished ceiling 1/2" (13mm) +1- 1/4" (6mm) Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 1/2" NPT or lS07-1R1/2 Temperature Ratings Nominal K-Factor: 4,9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy R/ Recessed" Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2_(Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res49 Residential Pendent Sprinkler Components and Installation Dimensions 91/4" 11 7-m) 1II" (7mm F2 & FV Recessed Escutcheon Installation Model Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage AreatZ ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14(4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0(0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20 (6.1 x 6.1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100(0200mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0 (0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20 x 20(6.1 x 6.1) 22(83) 20.2 (1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3 of 15 May 2019 Rellabild www.reliablesprinkler.com tqcci Fire Protection Products Worldwide Contacts I www.tyco-fire.com BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NL•tLg The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook lH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. Page 1 of 2 APRIL 2016 TFPI9I5 TFPI9I5 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www,tyco-fire.com GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco BLAZEMASTER is a trademark of The Lubrizol corporation. Fire Protection Products .251 I ARGCO STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC 'For mounting CPVC pipe to wood 'Flared edges help protect CPVC 'Galvanized steel Supplied with #10 hex head cap screws 'Complies with the static load requirements of NFPA® 13 'Suitable for fire protection installations Eliminates spacers or backup blocks Easy installation rr top mount bottom mount V(C) 4'! side mount All sizes can be used as a restrainer in the bottom position. The 3/4" size only can be used as a restrainer in the top position. C(&s File VlXH.EX6587 Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minumum 3/8" thickness. Provides vertical/lateral restraint and prevents upward movement of the pipe that supplies pendant fire sprinkler below ceiling. Installation: Per NFPA 13, 13R and 13D. (See attached) Space by pipe type. Install into wood, concrete or steel. Snap over pipe then squeeze strap back allowing pipe to slide. Fasteners: Wood - 3/410 3" cvc Pipe - wood screw - no pre-drill 3/4" to 2" copper Pipe - wood screw - no pre-drill 3/4" to 2" Steel Pipe - 1/4" x 1-1/2" lag screw - no pre-drill Steel - 3/4" to 3" cvc Pipe - 1/4" TEK screw 3/4" to 2" copper Pipe - 1/4" TEK screw 3/410 2" Steel Pipe - 1/4" TEK screw MAX. HANGER size cart 4 A B WANNA ERICO 3/4" 25-30-180-3/4 2.69" 3.25" 67" 597811 25-30-180-1 2.94' 3.25' 70' 597812 1-1/4" 25-30-180-1-1/4 3.31" 3.25' 79" 597813 1-1/2" 25-30-180-1-1/2 3.56" 4.5" 82" 597814 25-30-180-2 4.06" 5' 94" 597815 The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the users responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the users responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-8001-854-1015 OR LOG ONTO WWW.ARGCO.COM P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 cPvc DOUBLE OFFSET HANGER Hanger/Restrainer I SIZE-SYSTEM PIPE: 3/4" and 1" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - C®US 203 - EX 4231 LISTED PATENT - No. 6,702,236 FUNCTION - Support horizontal CPVC pipe. Provides listed vertical/horizontal restraint and prevents Hanger/Restrainer upward movement of pipe from pendent sprinkler discharge. INSTALLATION - Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13. #904 screw in wood - no pre-drill. FEATURES * Double 1 1/2" offset * Common center-line for 3/4" and 1". * Offset edge eliminates abrasion. * Required AFCON #904 screw included - 3/8" hex head. ORDERING - Part # and pipe size. Specific AFCON products urn exclusively designed to he compatible ONLY with other AFCONproduct.s including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. 4FCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 11/13 ARGCO CROSS REFERENCE Size Item # TflI MO i FRI(fl° 314" 25-30-175-3/4 012845 597827 1" 25-30-175-1 012869 597828 1-1/4" IPS 25-30-175-1-1/4 012876 597829 1-1/2" IPS 25-30-175-1-1/2 012883 597831 2" IPS 25-30-175-2 012890 597832 CPVC Two-Hole 90 0 Side Mount Strap -Top or bottom beam installation -Galvanized steel, supplied with I" hex screws c®us File VIXH.EX6587 Snap CPVC pipe hanger into hanger. Dimples hold pipe in place. Mount hanger onto wood beam with screws provided. May also be used on the underside of beam. Do anchor tightly to surface, be sure that pipe can slide freely through hanger. May be used as a guide in the upward position. Not designed to restrain upward movement of pipe. Installation and configuration shall conform to the requirements of the NFPA 13, instructions and applicable local codes. The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Designed for support or restraint fo piping in either a vertical or horizon- tal position. It can be used on top or bottom of a beam. The edges are flared to provent any damage to the CPVC pipe. It is easily attached using 2 hex head self-threading screws (supplied) c\.Jus File VlXH.EX6587 HEX HEAD SCREWS 114" 0 ARGCO CPVC TWO HOLE STRAP Galvanized steel construction 1. SNAP CPVC PIPE INTO HANGER. part # size 25-30-283 3/4" 25-30-284 1" 25-30-285 1.1/4" 25-30-286 1-1/2" 25-30-287 2" Galvanized steel, supplied with hex slotted screws MOUNT HANGER TO UNDERSIDE OF BEAM WITH SCREWS PROVIDED. MAY ALSO BE USED ON TOP SIDE OF BEAM. The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the users responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM f~ SYSTEM $ SENSOR® WFDTN Series Waterflow Detector System Sensor WFDTN T- Tap Wateruiow detectors are designed for primary signaling in residential systems and branch line signaling. Features New directional cover allows installers and inspectors to easily see the direction of flow UL-listed models are NEMA 4 rated New cover provides a better seal, is lighter weight, not painted and corrosion resistant Sealed retard mechanism immune to dust and other contaminants Less exposed metal reduces shock hazard, plastic cover acts as insulator and is resistant to arcing Visual switch activation Audible switch activation (73 dBA) Field-replaceable timer/switch assembly Accommodates up to 12 AWG wire Switch Synchronization activates both alarm panel and local bell or horn strobe Tamper-resistant cover screws Improved water sealing Reduced product weight Wire-ready terminals Improved wiring with new terminal block layout Snap-in optional cover tamper switch Agency Listings I&I <~ LISTED APPROVED S739 7770-1653:0231 30512266 The new WFDTN Series waterf low detectors from System Sensor consists of a rugged, NEMA 4-rated enclosure that is more damage resistant than previous metal designs. The watertlow detector is designed for both indoor and outdoor use, with the widest available temperature range, from 32°F to 150°F. Both the WFDTN with incorporated timer and WFDTNRN with immediate activation fit any tee that has a 1 in. NPT branch, including: 1 in., 1 ¼in., 11/2 in. and 2in. NPT threaded ferrous and brass tees; un., 11/4 in., l½in. and 2in. copper sweat tees; Tyco, Spears, NIBBCO brand 1 in. CPVC tees. Twelve different clearly marked plastic paddles are available to fit different installation configurations. UL-listed models are equipped with tamper-resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block with new layout designed to make wiring easy with wire ready terminals, COM terminals are on a different elevation, large barrier between switches and easy to read raised textured lettering all make wiring easy. An optional cover tamper switch is available, securely snaps into place, no tools required. The WFDTN incorporates a mechanical time delay feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the fire sprinkler system. The larger and easy to turn timer dial makes setting the waterflow detector easy with high contrast pad printed markings. The dial offers three tabs to help with turning, with one larger tab located on the dial position for approximately 60 seconds, a notch is also indicated on the dial to locate approximately 30 seconds making setting the detector in dimmly lit locations easy. The WFDTN series is designed for accuracy and repeatability. The detector also offers improved performance during vibration in riser applications where detectors are exposed to a large in rush of water. ARGCO FIRE ALARM BELLS ----S.--- 1ODIA.GONG ,- /\ / 7 N / \ \ 8' DIA. GONG I I 6" DIA. GONG , U )~x 4-3/8" Four wire, 120 and 24 volt Indoor and outdoor installation Weatherproof backbox 120 VAC: 6", 8", 10" 24 VAC: 6", 10" ( D RATING 6 GONG SIZE 8 GONG SIZE 10 GONG SIZE Rated Sound Level Rated Sound Level Rated Sound Level VOLTAGE Current at 1 Meter Current at 1 Meter Current at 1 Meter 6VDC 250mA 95dB 250mA 95dB 250mA 95dB 12VDC 180mA 95dB 180mA 95dB 180mA 96dB 24VDC 100mA 95dB lOOmA 95dB lOOmA 96dB 120VAC 25mA 95dB 25mA 95dB 25mA 98dB 220VAC 20mA 95db 1 20mA 95db 20mA 97db Back Box WIRING INSTRUCTIONS from control p preceding D.C. BELLS (observe polarity) RED (IN) / RED to next be//or end-of-line resistor preceding be/l from control panel or BLACK IN 10' ~'_BLA~CK(OLIT) When electrical supervisor is required use in and out leads as shown. Observe polarity to ring DC bells Red wires positive (+) Black wires negative (-) A.C. BELLS When electrical supervisor is required use in and out leads as shown. When using AC bells, terminate each extra wire separately after last bell End-of-line resistor is not required on AC belts. INSTALLATION: I. The bell should be mounted a minimum of 8 ft. from the floor or as close to the ceiling as possible. Remove the gong Connect the wiring (see diagram). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in th hole in the gong). Test all bells for proper operation that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). I 800-854-1015 www.argco.com FAX 760-727-3270 I