Loading...
HomeMy WebLinkAbout2668 GATEWAY RD; 180; FPC2020-0016; Permitj1 :1iIJI:11I']1i t~city of Carlsbad uiiiiieilaeiimlt Print Date: 02/22/2021 Permit No: FPC2020-0016 Job Address: 2668 GATEWAY RD, # 180, CARLSBAD, CA 92009-1783 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132622100 Track #: Applied: 01/29/2020 Valuation: $216,952.00 Lot #: Issued: 02/12/2020 Occupancy Group: Project #: Finaled Close Out: 02/22/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: GIAOLA - SPRINKLER TI (34 HEADS) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-6012-4665 1760-602-8561 f I www.carlsbadca.gov fra2o2 -oo Hydraulic calculations using HydraCALC Cosco Fire Protection, Inc 4990 Greencraig Lane San Diego, CA 92123 858-444-2000 Job Name Giola Italian Kitchen - Outdoor Dining Drawing : FP-100 Location : 2668 Gateway Road #180 Remote Area : I Contract : 10.CD_5952 Data File : 10.CD_5952 Giola Italian Kitchen.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Page 1 Date 1-29-2020 Cosco Fire Protection, Inc Giola Italian Kitchen - Outdoor Dining HYDRAULIC CALCULATIONS for Project name: Giola Italian Kitchen - Outdoor Dining Location: 2668 Gateway Road #180 Drawing no: FP-100 Date: 1-28-2020 Design Remote area number: I Remote area location: Outdoor Dining Occupancy classification: A2 Density: .10 - Gpm/SqFt Area of application: 1127 - SqFt Coverage per sprinkler: 225 Max. - SqFt Type of sprinklers calculated: Quick Response Pendent No. of sprinklers calculated: 10 In-rack demand: N/A - GPM Hose streams: 100-GPM Total water required (including hose streams): 345.665 - GPM Type of system: NFPA 13, Overhead Wet Volume of dry or preaction system: N/A - Gal Water supply information Date: 12-03-19 Location: Gateway Road west of El Fuerte Street Source: City of Carlsbad Name of contractor: Cosco Fire Protection, Inc Address: 4990 Greencraig Lane I San Diego, CA /92123 Phone number: 858-444-2000 Name of designer: M. Lovely Authority having jurisdiction: City of Carlsbad Notes: (Include peaking information or gridded systems here.) Remote Area reduction per NFPA 13 Section 11.2.3.2.3.1. @ 85.5175-Psi Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supply Curve C Cosco Fire Protection, Inc Page 2 Giola Italian Kitchen - Outdoor Dining Date 1-29-2020 City Water Supply: Demand: Cl - Static Pressure : 97.2 Dl - Elevation : 4.114 C2 - Residual Pressure: 22.2 D2 - System Flow : 245.665 C2 - Residual Flow : 6750 D2 - System Pressure : 85.518 Hose ( Demand) : 100 D3 - System Demand :345.665 Safety Margin : 11.375 150 140 130 120 R11° E10° 90 - -92- zz S 80 D u 70 R 60 40 E 50 30 - C2 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Cosco Fire Protection, Inc Page 3 Giola Italian Kitchen - Outdoor Dining Date 1-29-2020 Fitting Legend Abbrev. Name 1/ ~ 1 11/4 11/2 2 21/2 3 3'/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcd Colt C300 Horz Butt Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe arid CFdt.Aors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 I ( Pressure I Flow Summary - STANDARD Cosco Fire Protection, Inc Page 4 Giola Italian Kitchen - Outdoor Dining Date 1-29-2020 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. Si 11.0 5.6 18.76 na 24.25 0.1 225 7.0 S2 11.0 5.6 19.61 na 24.8 0.1 225 7.0 S3 11.0 5.6 19.67 na 24.84 0.1 225 7.0 S4 11.0 5.6 18.84 na 24.3 0.1 225 7.0 S5 11.0 5.6 20.4 na 25.29 0.1 225 7.0 S6 11.0 5.6 19.29 na 24.59 0.1 225 7.0 S7 11.0 5.6 16.14 na 22.5 0.1 225 7.0 S8 11.0 5.6 18.32 na 23.97 0.1 225 7.0 S9 11.0 5.6 21.34 na 25.87 0.1 225 7.0 S10 11.0 5.6 20.34 na 25.25 0.1 225 7.0 1 11.75 19.42 na 2 11.75 20.89 na 3 11.75 20.39 na 4 11.75 19.51 na 5 11.75 21.74 na 6 11.75 19.98 na 7 11.75 16.68 na 8 11.75 19.51 na 9 11.75 22.76 na 10 11.75 21.08 na 20 11.75 22.55 na 21 11.75 22.57 na 22 11.75 23.03 na 23 11.75 24.42 na 24 11.75 29.24 na 25 15.25 31.38 na 26 15.25 57.69 na 27 15.25 67.14 na 28 15.25 70.0 na TOR 15.25 75.9 na BOR 1.0 82.48 na UG1 -3.0 84.27 na UG2 -3.0 84.4 na BF1 3.0 81.85 na BF2 -3.0 87.29 na UG3 -3.0 87.34 na SCR 1.5 85.52 na 100.0 The maximum velocity is 21.57 and it occurs in the pipe between nodes 23 and 24 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Giola Italian Kitchen - Outdoor Dining Page 5 Date 1-29-2020 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SI II 5.60 24.25 1 2E 4.0 1.330 120 18.756 to 0.0 4.000 -0.325 1 11.750 24.25 1.049 0.0 5.330 0.1859 0.991 Vel = 9.00 0.0 1 24.25 19.422 K Factor = 5.50 S2 11 5.60 24.80 1 E 2.0 1.330 120 19.605 to 1 5.0 7.000 -0.325 2 11.750 24.8 1.049 0.0 8.330 0.1938 1.614 Vel = 9.21 0.0 2 24.80 20.894 K Factor = 5.43 S3 11 5.60 24.84 1 2E 4.0 1.330 120 19.674 to 0.0 4.000 -0.325 3 11.750 24.84 1.049 0.0 5.330 0.1944 1.036 Vel = 9.22 0.0 3 24.84 20.385 K Factor = 5.50 S4 11 5.60 24.30 1 2E 4.0 1.330 120 18.835 to 0.0 4.000 -0.325 4 11.750 24.3 1.049 0.0 5.330 0.1867 0.995 Vel = 9.02 0.0 4 24.30 19.505 K Factor = 5.50 S5 11 5.60 25.29 1 T 5.0 1.330 120 20.396 to E 2.0 7.000 -0.325 5 11.750 25.29 1.049 0.0 8.330 0.2010 1.674 Vel = 9.39 0.0 5 25.29 21.745 K Factor = 5.42 S6 11 5.60 24.59 1 2E 4.0 1.330 120 19.286 to 0.0 4.000 -0.325 6 11.750 24.59 1.049 0.0 5.330 0.1908 1.017 Vel = 9.13 0.0 6 24.59 19.978 K Factor = 5.50 S7 11 5.60 22.50 1 2E 4.0 1.330 120 16.143 to 0.0 4.000 -0.325 7 11.750 22.5 1.049 0.0 5.330 0.1619 0.863 Vel = 8.35 0.0 7 22.50 16.681 K Factor = 5.51 S8 11 5.60 23.97 1 E 2.0 1.330 120 18.316 to T 5.0 7.000 -0.325 8 11.750 23.97 1.049 0.0 8.330 0.1819 1.515 Vel = 8.90 0.0 8 23.97 19.506 K Factor = 5.43 S9 II 5.60 25.87 1 1 5.0 1.330 120 21.342 to E 2.0 7.000 -0.325 9 11.750 25.87 1.049 0.0 8.330 0.2095 1.745 Vel = 9.60 0.0 9 25.87 22.762 K Factor = 5.42 S10 11 5.60 25.25 1 2E 4.0 1.330 120 20.335 to 0.0 4.000 -0.325 10 11.750 25.25 1.049 0.0 5.330 0.2004 1.068 Vel= 9.37 Computer Programs by Hydratec Inc. Revision: 50.53.5 I Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Page 6 Giola Italian Kitchen - Outdoor Dining Date 1-29-2020 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 10 25.25 21.078 K Factor = 5.50 1 11.750 24.25 1 0.0 7.916 120 19.422 to 0.0 0.0 0.0 2 11.750 24.25 1.049 0.0 7.916 0.1860 1.472 Vel = 9.00 2 11.750 24.80 1.25 T 6.0 3.330 120 20.894 to 0.0 6.000 0.0 21 11.750 49.05 1.38 0.0 9.330 0.1798 1.678 Vel = 10.52 0.0 - 21 49.05 22.572 K Factor = 10.32 3 11.750 24.84 1 1 5.0 6.167 120 20.385 to 0.0 5.000 0.0 20 11.750 24.84 1.049 0.0 11.167 0.1943 2.170 VeI= 9.22 0.0 20 24.84 22.555 K Factor = 5.23 4 11.750 24.30 1 0.0 12.000 120 19.505 to 0.0 0.0 0.0 5 11.750 24.3 1.049 0.0 12.000 0.1867 2.240 Vel = 9.02 5 11.750 25.29 1.25 1 6.0 1.000 120 21.745 to 0.0 6.000 0.0 22 11.750 49.59 1.38 0.0 7.000 0.1836 1.285 Vel = 10.64 0.0 22 49.59 23.030 K Factor = 10.33 6 11.750 24.59 1 1 5.0 11.000 120 19.978 to 0.0 5.000 0.0 22 11.750 24.59 1.049 0.0 16.000 0.1908 3.052 Vel = 9.13 0.0 22 24.59 23.030 K Factor = 5.12 7 11.750 22.50 1 2E 4.0 13.460 120 16.681 to 0.0 4.000 0.0 8 11.750 22.5 1.049 0.0 17.460 0.1618 2.825 Vel = 8.35 8 11.750 23.97 1.25 1 6.0 14.000 120 19.506 to 0.0 6.000 0.0 9 11.750 46.47 1.38 0.0 20.000 0.1628 3.256 Vel = 9.97 9 11.750 25.87 1.5 T 8.0 1.500 120 22.762 to 0.0 8.000 0.0 23 11.750 72.34 1.61 0.0 9.500 0.1743 1.656 Vel = 11.40 0.0 23 72.34 24.418 KFactor= 14.64 10 11.750 25.25 1 T 5.0 11.670 120 21.078 to 0.0 5.000 0.0 23 11.750 25.25 1.049 0.0 16.670 0.2004 3.340 Vel = 9.37 0.0 23 25.25 24.418 KFactor= 5.11 20 11.750 24.84 2 0.0 3.000 120 22.555 to 0.0 0.0 0.0 21 11.750 24.84 2.157 0.0 3.000 0.0057 0.017 Vel = 2.18 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Giota Italian Kitchen - Outdoor Dining Page 7 Date 1-29-2020 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Fe ******* Notes Node2 Etev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 21 11.750 49.05 2 0.0 10.500 120 22.572 to 0.0 0.0 0.0 22 11.750 73.89 2.157 0.0 10.500 0.0436 0.458 Vet = 6.49 22 11.750 74.18 2 0.0 8.790 120 23.030 to 0.0 0.0 0.0 23 11.750 148.07 2.157 0.0 8.790 0.1579 1.388 Vet = 13.00 23 11.750 97.59 2 E 6.153 5.830 120 24.418 to 0.0 6.153 0.0 24 11.750 245.66 2.157 0.0 11.983 0.4027 4.825 Vet = 21.57 24 11.750 0.0 2 E 6.153 2.916 120 29.243 to 0.0 6.153 -1.516 25 15.250 245.66 2.157 0.0 9.069 0.4026 3.651 Vet = 21.57 25 15.250 0.0 2 2E 12.307 53.040 120 31.378 to 0.0 12.307 0.0 26 15.250 245.66 2.157 0.0 65.347 0.4027 26.313 Vel = 21.57 26 15.250 0.0 2 T 12.307 11.167 120 57.691 to 0.0 12.307 0.0 27 15.250 245.66 2.157 0.0 23.474 0.4027 9.452 Vet= 21.57 27 15.250 0.0 3 T 20.159 32.830 120 67.143 to 0.0 20.159 0.0 28 15.250 245.66 3.26 0.0 52.989 0.0539 2.855 Vet = 9.44 28 15.250 0.0 3 2E 18.815 70.500 120 69.998 to 1 20.159 38.974 0.0 TOR 15.250 245.66 3.26 0.0 109.474 0.0539 5.898 Vel = 9.44 TOR 15.250 0.0 4 E 13.167 15.000 120 75.896 to 0.0 13.167 6.172 BOR 1 245.66 4.26 0.0 28.167 0.0146 0.412 Vet = 5.53 BOR 1 0.0 6 E 20.084 10.000 140 82.480 to 0.0 20.084 1.732 UG1 -3 245.66 6.16 0.0 30.084 0.0019 0.056 Vet = 2.64 UGI -3 0.0 6 2E 43.166 34.000 150 84.268 to 0.0 43.166 0.0 UG2 -3 245.66 6.09 0.0 77.166 0.0017 0.131 Vet = 2.71 UG2 -3 0.0 6 E 20.084 6.000 140 84.399 to 0.0 20.084 -2.599 BFI 3 245.66 6.16 0.0 26.084 0.0018 0.048 Vet = 2.64 BF1 3 0.0 6 Zcd 0.0 6.000 140 81.848 to 0.0 0.0 5.434 * * Fixed Loss = 2.836 BF2 -3 245.66 6.16 0.0 6.000 0.0018 0.011 Vet = 2.64 BF2 -3 0.0 6 E, 20.084 6.000 140 87.293 to 0.0 20.084 0.0 UG3 -3 245.66 6.16 0.0 26.084 0.0018 0.048 Vet = 2.64 UG3 -3 00 6 E 21.583 6.000 150 87.341 to T 46.249 67.832 -1.949 SCR 1.500 245.66 6.09 0.0 73.832 0.0017 0.126 Vet = 2.71 100.00 Qa= 100.00 SCR 345.66 85.518 K Factor = 37.38 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hydraulic calculations using HydraCALC Cosco Fire Protection, Inc 4990 Greencraig Lane San Diego, CA 92123 858-444-2000 Job Name : Giola Italian Kitchen - Hood Connection Drawing : FP-100 Location : 2668 Gateway Road #180 Remote Area : I Contract : I0.CD_5952 Data File : 10.CD_5952 Giola Italian Kitchen Hood.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Cosco Fire Protection, Inc Page 1 Giola Italian Kitchen - Hood Connection Date 1-29-2020 HYDRAULIC CALCULATIONS for Project name: Giola Italian Kitchen - Core Hood System Connection Location: 2668 Gateway Road #180 Drawing no: FP-100 Date: 1-28-2020 Design Remote area number: I Remote area location: Kitchen Hood Occupancy classification: A2 Density: 29.8 - Gpm/SqFt Area of application: Core System - SqFt Coverage per sprinkler: 225 Max. - SqFt Type of sprinklers calculated: Core System Proof Calc No. of sprinklers calculated: I In-rack demand: N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 136.152 - GPM @ 45.425 - Psi Type of system: Supply to ANSUL Core System Volume of dry or preaction system: N/A - Gal Water supply information Date: 12-03-19 Location: Gateway Road west of El Fuerte Street Source: City of Carlsbad Name of contractor. Cosco Fire Protection, Inc Address: 4990 Greencraig Lane / San Diego, CA I 92123 Phone number: 858-444-2000 Name of designer: M. Lovely Authority having jurisdiction: City of Carlsbad Notes: (Include peaking information or gridded systems here.) Core Minimum Operating Pressure 35 psi Core Minimum Flow 29.8 gpm Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supply Curve C Cosco Fire Protection, Inc Page 2 Giola Italian Kitchen - Hood Connection Date 1-29-2020 City Water Supply: Demand: Cl - Static Pressure : 97.2 Dl - Elevation : 3.465 C2 - Residual Pressure: 22.2 D2 - System Flow : 36.152 C2 - Residual Flow : 6750 D2 - System Pressure : 45.425 Hose (Demand ) : 100 D3 - System Demand :136.152 Safety Margin : 51.721 150 140 130 p120 R110 C1 I E 100 90 - s 80 U 70 R 60 E 50 40 303 0 - ______ _______ _________ ___________ ____________ _______________ 20 10 ..... 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW ( N "1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Cosco Fire Protection, Inc Page 3 Giola Italian Kitchen - Hood Connection Date 1-29-2020 Fitting Legend Abbrev. Name % 3fl 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcd Colt C300 Horz Butt Fitting generates a Fixed Loss Based on Flow / Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure / Flow Summary - STANDARD Cosco Fire Protection, Inc Page 4 Giola Italian Kitchen - Hood Connection Date 1-29-2020 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SI 11.0 35.19 na S2 11.0 35.19 na S3 11.0 35.19 na S4 11.0 35.19 na S5 11.0 35.19 na S6 11.0 35.19 na S7 11.0 35.19 na S8 11.0 35.19 na S9 11.0 35.19 na S10 11.0 35.19 na 11.75 34.87 na 2 11.75 34.87 na 3 11.75 34.87 na 4 11.75 34.87 na 5 11.75 34.87 na 6 11.75 34.87 na 7 11.75 34.87 na 8 11.75 34.87 na 9 11.75 34.87 na 10 11.75 34.87 na Hi 9.5 6.2 34.0 na 36.15 0.1 100 34.0 20 11.75 34.87 na 21 11.75 34.87 na 22 11.75 34.87 na 23 11.75 34.87 na 24 11.75 34.87 na 25 15.25 33.35 na 26 15.25 33.35 na 27 15.25 33.62 na 28 15.25 33.71 na TOR 15.25 33.88 na BOR 1.0 40.06 na UG1 -3.0 41.79 na UG2 -3.0 41.8 na BF1 3.0 39.2 na BF2 -3.0 47.37 na UG3 -3.0 47.37 na SCR 1.5 45.42 na 100.0 The maximum velocity is 7.75 and it occurs in the pipe between nodes Hi and 26 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Page 5 Giola Italian Kitchen - Hood Connection Date 1-29-2020 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SI 11 0.0 I 2E 4.0 1.330 120 35.192 to 0.0 4.000 -0.325 1 11.750 0.0 1.049 0.0 5.330 0 0.0 Vel = 0 0.0 1 0.0 34.867 K Factor = 0 S2 11 0.0 1 E 2.0 1.330 120 35.192 to T 5.0 7.000 -0.325 2 11.750 0.0 1.049 0.0 8.330 0 0.0 Vel = 0 0.0 2 0.0 34.867 K Factor = 0 S3 11 0.0 1 2E 4.0 1.330 120 35.192 to 0.0 4.000 -0.325 3 11.750 0.0 1.049 0.0 5.330 0 0.0 Vel = 0 0.0 3 0.0 34.867 K Factor = 0 S4 11 0.0 1 2E 4.0 1.330 120 35.192 to 0.0 4.000 -0.325 4 11.750 0.0 1.049 0.0 5.330 0 0.0 Vel = 0 0.0 4 0.0 34.867 K Factor = 0 S5 11 0.0 1 T 5.0 1.330 120 35.192 to E 2.0 7.000 -0.325 5 11.750 0.0 1.049 0.0 8.330 0 0.0 Vel = 0 0.0 5 0.0 34.867 K Factor = 0 S6 11 0.0 1 2E 4.0 1.330 120 35.192 to 0.0 4.000 -0.325 6 11.750 0.0 1.049 0.0 5.330 0 0.0 Vel = 0 0.0 6 0.0 34.867 K Factor =0 S7 11 0.0 1 2E 4.0 1.330 120 35.192 to 0.0 4.000 -0.325 7 11.750 0.0 1.049 0.0 5.330 0 0.0 Vel = 0 0.0 7 0.0 34.867 K Factor =0 S8 11 0.0 1 E 2.0 1.330 120 35.192 to 1 5.0 7.000 -0.325 8 11.750 0.0 1.049 0.0 8.330 0 0.0 Vel = 0 0.0 8 0.0 34.867 K Factor = 0 59 11 0.0 1 1 5.0 1.330 120 35.192 to E 2.0 7.000 -0.325 9 11.750 0.0 1.049 0.0 8.330 0 0.0 Vel = 0 0.0 9 0.0 34.867 K Factor = 0 S10 II 0.0 1 2E 4.0 1.330 120 35.192 to 0.0 4.000 -0.325 10 11.750 0.0 1.049 0.0 5.330 0 0.0 Vel = 0 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Page 6 Giola Italian Kitchen - Hood Connection Date 1-29-2020 Node 1 Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0. 10 0.0 34.867 K Factor = 0 1 11.750 0.0 1 0.0 7.916 120 34.867 to 0.0 0.0 0.0 2 11.750 0.0 1.049 0.0 7.916 0 0.0 Vel =0 2 11.750 0.0 1.25 T 6.0 3.330 120 34.867 to 0.0 6.000 0.0 21 11.750 0.0 1.38 0.0 9.330 0 0.0 Vel = 0 0.0 21 0.0 34.867 K Factor =0 3 11.750 0.0 1 T 5.0 6.167 120 34.867 to 0.0 5.000 0.0 20 11.750 0.0 1.049 0.0 11.167 0 0.0 Vel = 0 0.0 20 0.0 34.867 K Factor =0 4 .11.750 0.0 1 0.0 12.000 120 34.867 to 0.0 0.0 0.0 5 11.750 0.0 1.049 0.0 12.000 0 0.0 Vel = 0 5 11.750 0.0 1.25 T 6.0 1.000 120 34.867 to 0.0 6.000 0.0 22 11.750 0.0 1.38 0.0 7.000 0 0.0 Vel = 0 0.0 22 0.0 34.867 K Factor = 0 6 11.750 0.0 1 T 5.0 11.000 120 34.867 to 0.0 5.000 0.0 22 11.750 0.0 1.049 0.0 16.000 0 0.0 Vel = 0 0.0 22 0.0 34.867 K Factor = 0 7 11.750 0.0 1 2E 4.0 13.460 120 34.867 to 0.0 4.000 0.0 8 11.750 0.0 1.049 0.0 17.460 0 0.0 Vel = 0 8 11.750 0.0 1.25 T 6.0 14.000 120 34.867 to 0.0 6.000 0.0 9 11.750 0.0 1.38 0.0 20.000 0 0.0 Vel = 0 9 11.750 0.0 1.5 T 8.0 1.500 120 34.867 to 0.0 8.000 0.0 23 11.750 0.0 1.61 0.0 9.500 0 0.0 Vel = 0 0.0 23 0.0 34.867 K Factor = 0 10 11.750 0.0 1 T 5.0 11.670 120 34.867 to 0.0 5.000 0.0 23 11.750 0.0 1.049 0.0 16.670 0 0.0 Vel = 0 0.0 23 0.0 34.867 K Factor = 0 Hi 9.500 6.20 36.15 1.25 2E 6.0 6.000 120 34.000 to T 6.0 12.000 -2.490 26 15.250 36.15 1.38 0.0 18.000 0.1023 1.842 Vel = 7.75 Computer Programs by Hydratec Inc. Revision: 50.53.5 .9 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Page 7 Giola Italian Kitchen - Hood Connection Date 1-29-2020 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 26 36.15 33.352 KFactor= 6.26 20 11.750 0.0 2 0.0 3.000 120 34.867 to 0.0 0.0 0.0 21 11.750 0.0 2.157 0.0 3.000 0 0.0 Vel = 0 21 11.750 0.0 2 0.0 10.500 120 34.867 to 0.0 0.0 0.0 22 11.750 0.0 2.157 0.0 10.500 0 0.0 Vel = 0 22 11.750 0.0 2 0.0 8.790 120 34.867 to 0.0 0.0 0.0 23 11.750 0.0 2.157 0.0 8.790 0 0.0 Vel = 0 23 11.750 0.0 2 E 6.153 5.830 120 34.867 to 0.0 6.153 0.0 24 11.750 0.0 2.157 0.0 11.983 0 0.0 Vel = 0 24 11.750 0.0 2 E 6.153 2.916 120 34.867 to 0.0 6.153 -1.516 25 15.250 0.0 2.157 0.0 9.069 0.0001 0.001 Vel = 0 25 15.250 0.0 2 2E 12.307 53.040 120 33.352 to 0.0 12.307 0.0 26 15.250 0.0 2.157 0.0 65.347 0 0.0 Vel = 0 26 15.250 36.15 2 T 12.307 11.167 120 33.352 to 0.0 12.307 0.0 27 15.250 36.15 2.157 0.0 23.474 0.0116 0.272 Vel = 3.17 27 15.250 0.0 3 T 20.159 32.830 120 33.624 to 0.0 20.159 0.0 28 15.250 36.15 3.26 0.0 52.989 0.0016 0.083 Vel = 1.39 28 15.250 0.0 3 2E 18.815 70.500 120 33.707 to T 20.159 38.974 0.0 TOR 15.250 36.15 3.26 0.0 109.474 0.0016 0.170 Vel = 1.39 TOR 15.250 0.0 4 E 13.167 15.000 120 33.877 to 0.0 13.167 / 6.172 BOR 1 36.15 4.26 0.0 28.167 0.0004 0.012 Vel = 0.81 BOR 1 0.0 6 E 20.084 10.000 140 40.061 to 0.0 20.084 1.732 UG1 -3 36.15 6.16 0.0 30.084 0.0001 0.002 Vel = 0.39 UGI -3 0.0 6 2E 43.166 34.000 150 41.795 to 0.0 43.166 0.0 UG2 -3 36.15 6.09 0.0 77.166 0 0.003 Vel = 0.40 UG2 -3 0.0 6 E 20.084 6.000 140 41.798 to 0.0 20.084 -2.599 BFI 3 36.15 6.16 0.0 26.084 0.0001 0.002 Vel = 0.39 BFI 3 0.0 6 Zed 0.0 6.000 140 39.201 to 0.0 0.0 8.167 * * Fixed Loss = 5.568 BF2 -3 36.15 6.16 0.0 6.000 0 0.0 Vel = 0.39 BF2 -3 0.0 6 E 20.084 6.000 140 47.368 to 0.0 20.084 0.0 UG3 -3 36.15 6.16 0.0 26.084 0.0001 0.002 Vel = 0.39 UG3 -3 0.0 6 E 21.583 6.000 150 47.370 to T 46.249 67.832 -1.949 SCR 1.500 36.15 6.09 0.0 73.832 0.0001 0.004 Vel = 0.40 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc Page 8 Giola Italian Kitchen - Hood Connection Date 1-29-2020 Node 1 Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes Node2 EIev2 Fact Qt Act Eqiv Len Total PfIFt Pf 100.00 Qa= 100.00 SCR 136.15 45.425 K Factor= 20.20 FA Computer Programs by Hydratec Inc. Revision: 50.53.5 San Diego Branch Office .00 0906 I 4990 Greencraig Lane $0 0000: cosco San Diego, CA 92123 * S. •• .. Fire Protection (858) 444-2000 fax: 444-2056 CA Lie.: C-16 #577621 www. coscofire.conz MATERIAL SUBMITTAL Date: 01-28-2020 Giola Italian Kitchen 2668 Gateway Road Suite G 180 Carlsbad, CA 92009 JOB # 1O.CD_5952 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: M. Lovely Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle i FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response (I V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: CE 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /4719 mm of adjustments. Coverage jAc- ta uI i c r 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Bar, multiply SA. units by 10.0. For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. K, Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 un in )AA )r V i I,d,I,I flh/)fl)fl Il )flfl \Ii-fI- r-nn, MI victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories t Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm LI Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: LI Open End: V27 LI Recessed: V27-2 Sprinkler Finishes: LI Plain Brass LI Chrome plated LI White polyester coated3 LI Black painted3 LI Custom painted3 LI Proprietary Nickel Tefloi2 coating3 LII VC-2504 155, 2010, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. ,in in 14,1,1 7,, V i ni p7nn 14 )n,o\,;,.fI;,. -,,s,,, 511 ,i.-sh+ If victaulic.copi I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.1 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68"C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F179°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286"F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68"C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C FM 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141 "C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141"C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C NYC/MEA 62-99-E 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141 "C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360'F/1 82'C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68"C 155°F/68°C 155"F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141"C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C VNIIPO 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/1 41 °C 286° Ff141 'C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°Ff68°C None 155°F/68°C 155°F/68°C None 200° F/93 'C 200°F/93°C 200"F/93'C 200°F/93°C 135'F/57°C 155°F/68°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/1 82°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C For K Factor when pressure is measured in Bar, multiply S. I. units by 10.0 FM Approved with /2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. An in 7RAA 0, L( I Al 190')0 wl ')rlon \It,,,Ij,. ISIl victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Dimensions: f 6 6 2 60 1W! 2/s7 41 mm 60 mm 17A6/ 37 mm Standard Pendent - Standard Upright— V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Min.Hole 13A67 '116/ Typical Ceiling Tile 0 17 mm m 4 1 111/! lA/I Finished Surface 30nm 43 mm _________ MAXIMUM RECESS 21316/ - 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) '31oI J.__ 24 mm "MI 18mm 37 mm '3167 "I V 24 mm 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) An An in ,l,i,i O V I Ind,f (11I3(Y)Cl \ )fl)fl II victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent 10' 3.om 8' 2.4n 6' 1.8n 4, 1.2m 2' 0.6m 7 psi — 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2' 4' 6' 8' 10' 12' 14' 0.6,,, 1.2m I.B. 2.4,,, 3.Om 3.7m 4.3,,, Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory s. IIIIIIIIiç,II IIIIIIIIIIi1\I 2' 4' 6' 8' 10' 12' 14' 16' 0,6,,, 1.2,,, iOn, 2.4m 3.sm 3.7, 4.3m 4.9m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. Afl in L,1A On,, V 1 Ir,dn+n, Al I')A')A ( ')A')fl \Ij'+s,,ii' P,,,,,, All ,n,,,,,,,nd 30n 8' 2.4m 6' 1.8m 4, Un, 2' 0.6m 0 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 Ff38 C Orange Ordinary C 155 F/68 C 100 Ff38 C Red Intermediate E 175 Ff79 C 150 Ff65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F 8f107 C Blue Extra High 7 K 360 F1182 C 300 Ff149 C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. Available Wrenches: V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703, V2704 Upright WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 610 I&M 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equioment without notice and without incurring obligations. Trademarks Victaulic is registered trademark of Victajlic Company. ,in in )xAA Q, V 1 I,l 691 ,n,rl lIi,,f,Ii, -on, All FireLock® V27, K5.6 Models V2709,V2710 Standard Spray Horizontal and Recessed Horizontal Sidewall Standard and Quick Response V2709/V2710 V2709/V2710 Standard Horizontal Recessed Horizontal Sidewall Sidewall Approvals/Listings: C®US LISTED See Victaulic Publication 10.01 for more details. Product Description: These Model V27, standard spray horizontal sidewall sprinklers are designed for up to ordinary Hazard per NFPA 13, and can be used for standard or recessed installations. The design provides a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temprature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to I4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. \%ta ulicr 40.11 Technical Specifications: Models: V2709, V2710 Style: Horizontal Sidewall or Recessed Horizontal Sidewall Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: 1/2 /15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 AA 11 Or AR O, V fl7/fl1A n, 001/1 \/f,,d All lht / victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Material Specifications: Horizontal Deflector: Commercial bronze per UNS C22000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: LII Standard: 5.0 mm Quick Response: 3.0 mm Load Screw: Low Silicon bronze per UNS C65100 Pip Cap: Low Silicon bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: Open End: V27 LI Recessed: V27-2 Sprinkler Finishes: LII Plain Brass LI Chrome plated LI White polyester coated3 LII Flat black painted3 LI Custom painted3 LII Proprietary Nickel/Teflcn2 coating3 LI VC-2504 155, 200, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. NOTE: Weather resistant recessed escutcheon available upon request. 2 Teflon is a registered trademark of Cupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. Afl 11 O, U 07/')fll,l n, 'r1A 4/,.f Ii- All victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Approvals/Listings: Model APPROVALS/LISTINGS V2709 V2709 Recessed V2710 V2710 Recessed V2710 Recessed Orifice Size (inches) 1/2' 1/2 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S. 1.5 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick Quick Recessed Recessed Recessed Deflector Type Horizontal Horizontal Horizontal Horizontal Horizontal Sidewall Sidewall" Sidewall Sidewall (up to Sidewall (up to ½" adjustment) 3/4" adjustment) Approved Temperature Ratings F°/C° 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C cULus 175°F/79°C 155°F/68°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141 °C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/1 82°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C FM 175°F/79°C 155°F/68"C 155°F/68"C 175°F/79°C 155°F/68°C None 200°F/93°C 175°F/79°C 175°F/79°C 286°F/1 41°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/1 82°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57"C 135°F/57°C 135°F/57°C NYC/MEA 6 #62-99-E 175°F/79°C 155°F/68°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 200°F/93°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 286°F/141°C 200°F/93°C 200°F/93°C 360°F/1 82°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C CSFM 6 #7690-0531:112 175°F/79°C 155°F/68°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 200°F/93°C 175°F/79°C 175°F/79°C 286°F/141 °C 200°F/93°C 286°F/141°C 200°F/93°C 200°F/93°C 360°F/1 82°C i35°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB 6 104b/01 175°F/79°C None 175°F/79°C None None 6 104b/02 200°F/93°C 286'F/1 41'C 200°F/93°C 360°F/1 82°C 86°F/141°C 2 135°F/57°C 135"F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 155°F/68°C i75°F/79°C 155°F/68°C None 200°F/93°C 175°F/79°C 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93 °C 200"F/93°C 360'F/1 82'C 286°F/141°C CCCf Z ST B S None None None None 155°F/68°C For K Factor when pressure is measured in Bar, multiply S. I. units by 10.0 6 Light Hazard ONLY Note: Listings and Approvals as of printing. All are approved open. AA 11 ')S,IC Pa,, V 1 07I0fl1A 55 0(1fl \1hfo,,Ij, , 511 1kf I victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publicaton 40.11 0 Dimensions: Y/89 mm H 21/4757 mm 32 mm Standard HSW - V27091 V2710 17 MM 56 mrn MM 30mm Finished Ceiling ~ 4- 1271i-3OS mm 4- l7/iCL3O5mm 'J m5hed 9 Min. Hole Max. Hole 725/ mm MiHole Max. Holo Finished Surface Finished ,urfa:e Typical Wall Typic Wall MAXIMUM EXTENSION MAXIMUM RECESS ½ Adjustment Recessed - V2709, V2710 (drawhg not to scale) 'A 24 rn -56rnn,37 s8mm 33 MMI F ,rished cuing Finished Ceiling 4 127102 rn 4 12'/l 02 305 mm FeNFFA __ _-_--- 256/6100n 2/51 mm 256/60 run- M,n, Hole Mao Hole 75 mon M. Hole Max. Finished Surface I I Finished Surface I 5— Typical Wall —I I— Typical lsli MAXIMUM EXTENSION MAXIMUM RECESS 3/4"Adjustment Recessed - \2709, V2710 (drawing not to scale) AA 11 ')AO pu,, V lldn+od fl7lOfllfl 01 0fl1A 5Iiuf,Ii All / victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Distribution Patterns: 10' G" 3.0 m 8' 2.4 m 6' 1.8 m 4, 1.2m 2' 0,6 m 0 Models V2709, V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns - Trajectory 7p51 48 kPa 15 psi 103 kPa 30psi •_____, 207 kPa 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0,6m 1,2m 1,8m 2.4m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m Models V2709, V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns - Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 8.5m °± .. J, 4.3m 0 ..................._:____0 16' 4.9 m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. An 11 ')RAF, V I I,-,,-1 I,,,-I 071')fllfl (F )(51,1 s,:,-*,,,I,- All victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature— Ft Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 Ff68 C 100 Ff38 C Red Intermediate E 175 Ff79 C 150 F/65 C Yellow Intermediate F 200 Ff93 C 150 Ff65 C Green High J 286 F/1 41 C 225 Ff107 C Blue Extra High 7 K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb Standard response only. V27-2 Recessed V27 Open End No escutcheon / / With escutcheon / - A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. O For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: I&M NO 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our weboite at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to by installed in accordance with current Victaulic installation/assembly instructions. Vict.sulic reserves the right to change procuct specifications, designs and standard eqs pment without notice and without incurring obligations. Tracemarks Victaulic is registered trademark of Victaulic Company. Afl 11 7IAR D V I I-I,4d (771'7fl1A wl )fl1A \5,fo II' MI FireLockTM V36, K5.6 Models V3605, V3606 Dry Type Pendents Standard and Quick Response I, 11Th1. Sleeve 111.IIrni 1.0 PRODUCT DESCRIPTION Models: V3606 and V3605 Style: Pendent, Recessed Pendent or Intermediate Level Pendent Nominal Orifice Size: 1/2713 mm K-Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: 1' NPT/25 mm BSPT Max. Working Pressure: 175 psi/1207 kPa/12 bar Factory Hydrostatic Test: 100% @ 500 psi/3447 kPaI34 bar Mm. Operating Pressure: 7psi/48 kPa/.5 bar Temperature Rating: See table in section 2.0 For K-Factor when pressure is measured in bar, multiply S. I. units by 10.0. JtauIicr 40.60 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victauliC.Com Afl CA OlflO fl_,. 11 1 flfl/flfllfl -- MI ;_kt ..:...i..... .i:. 2.0 CERTIFICATION/LISTINGS C@. <R> 4) USTE Model V3605 V3605 V3606 V3606 APPROVALS/LISTINGS Orifice Size (inches) ½ ½ ½ ½ Orifice Size (mm) 13 13 13 13 - Nominal K Factor Imperial 5.6 5.6 5.6 5.6 Nominal K Factor SI.2 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick DeflectorType Pendent Recessed Pendent Pendent Recessed Pendent Approved Temperature Ratings 135°F/57°C I 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68C 155°F168°C I 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 200°F/93°C I 200°F/93°C 286°F/141°C 286°F/141°C 286°F/1 41°C 286F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C FM 155°F/68°C 155°F/68°C 155°F/68°C 155'F/68'C 200°F193°C 200°F/93°C 200°F/93°C 200°F/93°C 286'F/1 41'C 286°F/i 41°C CCC 155°F/68°C I 155°F/68°C . None None 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTE Listings and approval as of printing. Temperatures are listed for all hazards and approved for V3605 and V3606 dry sprinklers up to 48° length. CCCf approved for V3605 dry sprinklers 107 to °1250 mm/4.2 - 49.2 in length. 40.60 3123 Rev K Updated 02/2019 0 2019 Victaulic Company. All rights reserved. Exaggerated for clarity victaulic.copi 3.0 SPECIFICATIONS - MATERIAL Deflector: Brass or stainless steel Bulb: Glass with glycerin solution Bulb Nominal Diameter: LI Standard: 5.0 mm LI Quick Response: 3.0 mm Split Spacer: Stainless steel Load Screw: Brass Pip Cap: Stainless steel Spring Seal Assembly: TeflonTM3 coated Beryllium nickel alloy and stainless steel Frame: Die cast brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless steel Orifice Insert: Stainless steel Escutcheon/Plate: 1010 - 1018 mild steel and stainless steel Torsion Spring: SST Wire Installation Wrench: Model V36 Open End and Recessed Wrenches fit all V36 Series frames. Sprinkler Finishes: L Plain brass L Chrome plated E White painted4 LI Flat black painted4 L Custom painted4 LI VC-2506 Teflon- is a registered trademark of Dupont Co. Not available on the Intermediate Level Style Pendent. UL Listed for corrosion resistance. 6 UL Listed and FM Approved for corrosion resistance. NOTE Weather resistant escutcheon available upon request. For cabinets and other accessories refer to separate sheet. 40.60 3123 Rev K Updated 02/2019 0 2019 Victaulic Company. All rights reserved. If 4.0 DIMENSIONS Tee with same outlet size fl-------fl Tee with same outlet size as sprinkler thread size. ,.. - as sprinkler thread size. See "Important Installation See "Important Installation Information",later in this Information" later in this document - - document NPT 1 • NPT 1/4" Min. Dia, HoIeinCeiling (Min. 1114") 1½ Mm Dia (Mm. 1¼ Escutc Two P T Hole in Ceiling 0 '73/32" 2½" Mw. 3 Dia. 1 4" Max. - Flush Sleeve and Skirt Tee with same outlet size as sprinkler thread size. See "Important Installation I I Information" later in this document NPT (Mm. 1½') ¼' II 3" Dia. Intermediate Level Pendent [t fl Tee with same outlet size as sprinkler thread size. See "Important Installation -- Information'l later in this 1" NPT document 1½" Min. Dia. (Min. 11/4') Hole in Ceiling 3½" 7 tw 334" Mm. T Two Piece 5" Max. Escutcheon Extended Tee with same outlet size as sprinkler thread size. See "Important Installation lnformation'l later in this PT document (Mn II Plain Barrel Tee with same outlet size as sprinkler thread size. -- Installation lnformation'l later in this 1 NPT document "A" Mi Dia. r 2" Hi (Mm. 1¼") e in Ceiling Min. Ceiling Cup "Max. 2bia" Dia. Recessed NOTE The "A" dimension of a dry sprinkler, which extends into a freezer from a wet piping system, must take into account the wall or ceiling thickness of the freezer. See IMPORTANT INSTALLATION INFORMATION later in this document. 40.60 3123 Rev K Updated 02/2019 0 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Contact Victaulic for performance details. 6.0 NOTIFICATIONS WARNING m Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designers responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 40.60 3123 Rev K Updated 02/2019 0 2019 Victaulic Company. All rights reserved. virfaiilirrnm 7.0 REFERENCE MATERIALS Important Installation Information: For detailed installation instructions, see publicabon 1-40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18. Excessive force may distort the frame thus destroying the unit. No. 2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee. No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NOT install dry sprinklers into any fitting that interferes with thread penetration. NOTE: The end seal of the dry sprinkler MUST NOT bottom out in the fitting. TYPICAL SLEEVE AND SKIRT CONFIGURATION FOR EXAMPLE ONLY End Seal I I HEATED SPACE CExpod Miflifl,,,fl, Length (Ref Barrel Table) thl e Marnater r ddpo h of ascutcheo n 'id be __—fo,,,ing, p, NFPA See 4ow Insulation Wall or Calling ofr reav N COLD SPACE NOTE The "A" dimension of a dry sprinkler, which extends into a freezer from a wet piping system, must take into account the wall or ceiling thickness of the freezer. The minimum length of the dry sprinkler should not be less than the lengths specified in the following table, plus the thickness of the freezer's wall or ceiling ("A" = 'c" + "D"). Refer to the drawing for a representation of the 'A" dimension. DO NOT attempt to modify dry sprinklers, since they are manufactured to this specific "A" dimension. The following table is used when the ambient temperature is maintained between 40°F/4°C and 60°F/16°c around the wet piping system. Ambient Temperature Exposed Exposed Minimum Barrel Length to Discharge End of Sprinkler inches/mm °F 40°F 50°F 60°F °C 4°C 10°C 16°C 40 0 0 0 4 0 0 0 30 0 0 0 -1 0 0 0 20 4 0 0 -7 102 0 0 10 8 1 0 -12 203 25 0 0 12 3 0 -18 305 76 0 -10 14 4 1 -23 356 102 25 -20 14 6 3 -29 356 152 76 -30 16 8 4 -34 406 203 102 -40 18 8 4 -40 457 203 102 -50 20 10 1 6 -46 508 254 152 -60 20 10 6 -51 508 254 152 40.60 3123 Rev K updated 02/2019 © 2019 Victaulic company. All rights reserved. victaulic.corn 7.0 REFERENCE MATERIALS (CONTINUED) Ratings: All glass bulbs are rated for temperatures from -67°F/-55°C to those shown in the table below. Temperature Nominal Temperature Maximum Ambient Rating Temperature Allowed Sprinkler Temperature °F °F Classification °C Glass Bulb Color Ordinary 135F 100F Orange 57C 38C Ordinary 155F 100F Red 68C 38C Intermediate 200F 150F Green 93C 65C Intermediate 286F 225F Blue 141C 107C Available Wrenches: Model V36 Open End and Recessed Wrenches fit all V36 Series frames. 7.1 REFERENCE MATERIALS - 10.65: Victaulic FireLockTM IGS Instal lation Read yTM Style V9 Sprinkler Coupling 25.14: Victaulic IGS Groove Specifications l-V9: Style V9 Victaulic FireLocknM IGSTM lnstallationReadyTM Sprinkler Coupling 1-40: Victaulic FireLocknM Automatic Sprinklers Installation and Maintenance Guide User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safely, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the united States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products lobe installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries, 40.60 3123 Rev K Updated 02/2019 0 2019 Victaulic Company. All rights reserved. FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL® and C-UL Listed. Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10, 1-8 NPS) ASTM A795, Type E, Grade A (Schedule 40,1-2 NPS) ASTM A53, Type E, Grade B (Schedule 40,2-8 NPS) ASTM A53, Type F, Grade A (Schedule 40,1-4 NPS) NFPA® 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black or hot-dip galvanized, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: LI BLACK LI HOT-DIP GALVANIZED 700 South Dock Street ufoawheaUand corn Sharon, PA 16146 wheatiand.com Tube P 800.257.8182 Follow us on Twitter: A DIVISION OFZEKELMAN INDUSTRIES F 724.346.7260 tdMheatlanclTube SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINALWALL WT./FT. H2OFILLED PCS./LIFT 21' 24' 25' UL mm in- mm ___ lbs L CRR 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 11/4 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 1'/a 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 2'/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 2.1 SCHEDULE 40 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOM INALID NOMINAL WALL WT./FT. H2OFILLED PCS./LIFT 21' 24 25' UL 111 in ir [ mm [ In mm lbs [ibs[ lbs CRR 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 11/4 1.660 42.2 1.380 35.1 0.140 3.56 2.27 2.922 51 2431 2778 2894 1.000 U/a 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.109 24 1845 2108 2196 1.000 2% 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 77.9 0.216 5.49 7.58 10.783 13 2069 2365 2464 1.000 3'/2 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 168.3 6.065 154.1 0.280 7.11 18.99 31.498 5 1994 2279 2374 1.000 8- 8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 -'-- 5 3001 3430 3573 1.000 Calculated using Standard UL CRR formula, UL Fire Protection Directory Category VIZY The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). S NPS Schedule 40 is FM Approved but not UL Listed. C@ APPROVED 700 South Dock Street infoti-wheatland.com - wFS-081619 Sharon, PA 16146 wheetland.com Tube P800.257.8182 Follow us on Twitter: '1 F 724.346.7260 ,dWheatIandTube A DIVISION OFZEKELMANINDUSTRIES SECTION 10 TEELOXTM MECHANICAL BRANCH CONNECTOR Designed for fast installation of bolted branch outlets, leeloxTM mechanical branch connectors are practical alternatives to existing branch connect systems. Made from high quality cast iron, leeloxlM are - known for long-lasting, maintenance-free performance. Key Features: T7 • A high grade EPDM rubber gasket surrounds the locating collar for accurate, permanent installation and the best seal in the industry. The locating collar is an integral part of the casting. A zinc-plated high-tensile steel U-bolt ensures rust-free attachment. TeeloxlM is approved for conventional and arm-over installations. NPS Pipe Center Center to Outlet A Hole Dia. Take uUt 11/4x1/2 1.98 1.19 1.19 1 1/4x314 2.05 1.19 1.19 11/4x1 2.13 1.19 1.19 11/2x1/2 1.98 1.19 1.19 1 l/2x3/4 2.05 1.19 1.19 1 l/2x 1 2.13 1.19 1.19 2x1!2 2.26 1.19 1.41 2x3!4 2.33 1.19 1.41 2 x 1 2.41 1.19 1.41 2112x1/2 2.57 1.19 1.78 21/2x 3/4 2.64 1.19 1.78 21/2x1 2.72 1.19 1.78 onTASTIVITAX261C iiTiiiiiii1 E. U1B'It: Zinc PlatedHiijensiIe Steel EiimeDSions: gNSI/AME! essur.eiRli If9sIiti5JL Ciings: ASTM[B633!!fSMTIK[53 r1ditiTI UL UIC1IFAMhereIappIiIJl IifiE'iions: Torque 2Oti'lbsrnax. Requirement: 01 B NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT - A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 21/2 CB90077 300 2.70 2.70 1 4.75 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE - A - B 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1.94 2.51 2 CT666 300 2.25 2.25 3.96 21/2 C1777 300 2.70 2.70 6.45 lb NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A - - B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 1 CB450551 300 1.43 1.43 1.80 2 1 CB450661 300 1.68 1.68 2.79 C.I. THREADED FITTI NGS FITTINGS Al)irLionojStar Pipe LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 ri CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTMA126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME 1316.14. THREADS ARE NPT PER ANSI/ASME 131.20.1. , ZL, __', f(T_: NOMINAL SIZE (INCH) ITEM MAX. DIMENSIONS CODE WORKING - - P.S.I. A B WEIGHT EACH PIECE 1X112 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 38 NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPLOO4 300 1.36 0.44 11/2 CPLOOS 300 1.45 0.62 2 CPLOO6 300 1.56 0.91 i ._.i i Iii 5 FITTINGS ofStarPipP,od,, (q (~~ <@> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST'RON CROSS I NOMINAL SIZE (INCH) I ITEM CODE ' MAX. WORKING P.S.I. DIMR4SIONSI WEIGHT EACH EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1 1.65 1 1.80 2.40 2X1 CX063 300 1 1.73 1 2.02 2.75 tASTIRON REDUCING TEE NOMINAL SIZE (INCH) ITEM CODE I MAX. WORKING P.S.I. ' DIMB'ISIONS WEIGHT EACH PIECE A B C 1X1X1/2 ff 300 1F 1.26 1.36 0.95 lxi X3/4 300 1.37 1.37 1.45 1.10 1X112X1 300 -150 1.36 1.50 18 1 X3/4X1 300 - xi 1 :T8 T.350- 1.45 1.50 1/4 C 300 17 1.67 1.58 132 iXiXi 1/2 300 iä 1.80 1.65 17 1 1/4X1 X11/2 CT431 300 134 1.26 1.53 1T7 1 1/4X1 X3/4 C1432 300 14 1.37 1.62 13 1 1/4X1X1 CT433 300 139 1.50 1.57 1.47 1 1/4X1 X1 1/4 CT434 300 175 1.67 1.75 1.80 1 114X1X1 1/2 C 143 300 1.88 1.80 1.82 -235- I 114X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 114X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 114X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 1 1/2X1X1/2 CT531 300 14T 1.34 1.66 1.41 1 1I2XlX3/4 CT532 300 131 1.37 1.75 1.65 1 172X1 XT---- CT533 300 ir 1.50 1.80 -7795-- 1 1/2X1X1 1/4 CT534 300 1 1.67 1.88 2.00 1 1/2X1 X1 1/2 CT535 300 14 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 141 1.34 1.66 1.58 1 1/2X1 1/4X3/4 CT542 300 15 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 ir 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 181 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 30 1.94 1.88 1.94 245 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 112X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1I2Xi 1/2X3/4 CT552 300 1.52 1.52 1.75 1 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1 1.94 1 1/2X1 1/2X1 1/4 CT554 300 _1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1 X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 _1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 1 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 C1656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 1 CT665 300 2.02 2.02 2.16 11 .72 2x2x2 1/2 T CT667 300 2.60 2.60 1 2.39 1 5.10 Page 39 Not less than Wood Flooring. SAMMYSO FOR WOOD . No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. t4tch a i/idea demonst,tion\ = www.itwbulldex.co ) 1/4" 8002957 GST 100 - 1/4 x 1" 210 (7/16'OSB) 25 125 i/4'_8003957 GST 200 1/4x2 1760 (Fir)- 25 125 i/ 3/8 8007957 GST 10 1/4 xl 210 (7116'OSB) 300 25 125 [38 8008957 GST 20 1/4x2 1760 (Fir) 850 75 25 -125 3/8 8068925 GST 20-SS 114x2" 1760 (Fir) -- 850 - 25 - - 125 #14 Black [ - 3/8 - 8009925 GST 25 380 3/8x 21/2 2113 (Fir) 1500 25 125 Nut Driver . 3/8" 8010957 GST 30 - 1/4 x 3' 2060 (Fir) 1500 1475 25 -- 125 Part #8113910 3/8 8069925 GST3OSS 1/4X3 - 2060 (Fir) - 25 125 1/2" 8013925 GST 2 1/4 x 2' 1760 (Fir) 25 125 1/2 - 8015925 GST3 1/4x3 - 2275 (Ftr) - - -- 25 125 #14 SW Red Nut Driver Part # 8114910 OR MMUFACWRED USX 17 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not less than 2" nominal width (1-1/2") UP 103-1/2" pipe; not less than 3" (2-1/2") nominal width 4 & 5" pipe I Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply 102" or thicker nailing strips resting on top of /1(1 steel beams. Floor Joist No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a video demonsiraiion www.itwbulldex.comJ 'IT Q 8019957 [ - 318" 8020957 I 3/8" 8021957 L 1/4" 3 - 3/8" 8073925 318"" - 8022925 #14 SW Red L - 3/8" 8023925 Nut Driver Part #8114910 May require pre-drilling; consult joist manufacturer, SWG 200 114x2" 1725 (Fir) 25 125 SWG 10 1I4x 1 622 (FIr) 300 25 125 SWG 20 1/4 x 2' 1725 (Fir) 1050 25 125 SWG 20-SS 1/402" 1725 (Fir) - 850 25 125 SWG 25-380 3/8x2-1/2' 2249 (Fir) 1500 - 25 125 SWG 30 1/4 x 3 1884 (Fir) 25 125 Eliminates distortion of threaded rod. "Accommodates up to 3 %" x 12 pitch roof. "Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Rod Part Approvals Size Number 1 0L . & . Nut Driver -1_ iit' 3/8" 8139957 S Part#8113910 EL - 1903 Dim Lumber I I 3/8 8269957 SFI-GST/CST2O 5/16x1-3/4" 1406@45"oflvertical J L Dim. Lumber I 903 Dim. Lumber 112 8303957 SH-GST/CST2.0 5/16x 1-3/4' 1406@45°off vertical L Dim. Lumber -: - - * May require pre-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Part # 8273910 1500 850 @45° 25 125 25 125 111 SAMMYSO FOR STEEL F Y'Th'h Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2 thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Manufactured in the U.S.A. WavM a video demonsrraiion wwwiwbulldex.comJ #14 Black Nut Driver Part #8113910 1- #14 SW Red Nut Driver Pan # 8114910 1/4" 8024957 DSTR 100 * 1/4-20 xl" TEKS 3 1510 (20 ga.) .036"-20 ga 3/16 25 125 - 1/4'-8025957 DST 100 1A-14 x I TEKS 3 - 446 (20 ga) - .036"-20 ga 3/16 25 125 j 1/4" 8026957 DST 150 1/4-14 x 1-1/2 TEKS 3 970 (16 ga.) .036-20 ga 3/16 25 125 1/4" 8027957 DST 200 1/4-14x2" TEKS 3 446 (20 ga.) -- - .036-20ga 3/16" 25 - 125 1/4" 8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3116") .188"-3/16" 1/2 25 125 3/8 8038957 DSTR1 - 114 20x1 TEKS 1510 (20ga) 15001475 036-"--20ga 3/1625 1251 "&" 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16') 1500 1475 .060'-16 ga. 1/2" 25 125 I 3/8 8039957 DSTR 5/1618x1-1 /4TEKS3 2200 (2Oga) 15001475 -.036"-20ga 3/16 25 1255 3/8' 8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) .036"-20 ga 3/16' 25 125 970 (16 ga.) [ 3/8" 879 DSTISS 1/4-147EKS3446 (20 - - .03g3/16" 25 125 1 IL 3/8" 8041957 DST 15 1/4-14 x 1-1/2' TEKS 3 446 (20 .036-20 ga 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) .036'20 ga 3/16" 25 125 970 (16 ga.) .,----. 3/8" 8042957 DST 20 1/4-14 x 2" TEKS 3 446 (20 .036-20 ga 3/16" 25 125 - 6(2Oa) -- 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 3/8' 8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16") 1500 1475 .125-1/8" 3/16" 25 125 - 3/8_ 8046957 TEK SO 1224x11/2 TEKSS 3125_(3i16') 1500 1475 2501/4 1/2 25 125 1/2" 8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 .188-3/16" 1/4" 25 125 970 (16 ga - 1/2" 8033925 DSTR1.0" 1/4-20x1" TEKS 3 1510 (20 ga.) - .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16 * 5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.) .036-20 ga 3/16" 25 125 1/2" 8035925 DST 5.16 5/16-38x1-1/4"TEKS3 1500 (3/16") - ----- .125-1/8" 3/16" 25 125 — 1/2" 8036925 TEK 5.0 12-2401-1/2" TEKS 5 3125 (3/16") .188-3/16" 1/2" 25 - 125 "Includes retaining nut SPECIAL NIT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins vt*awcumousA free. tnstallat on is then complete. Warranty requires the use of the appropriate nut driver for installations. Made with Tekse self-drilling fasteners - no pre-drilling required. - Installs into steel range from 20 gauge - 1/2' thicknesses. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. a video demsnsfraOon\ Manufactured in the U.S.A. ., wwwJwbullde) i- #14 SW Red Nut Driver Part # 8114910 1/40 8047957 SWD lOU 1/4-14 x TEKS 3 1477 (16 ga.) .060'-16 ga - 3/160 25 - 125 1/4 8049957 SWDR 100 1/420 xl TEKS 3 1900 (20 ga) - - 03620 ga 3/16 25 125 3/8" 8050957 SWD 10 1/4-14 x 1° TEKS 3 1477 (16 ga.) .060°-16 ga 3/160 25 125 3/8 8080925 SWD 10 SS 1/414 xl TEKS 3 1477 (16 ga.) .060'-16 ga 3/16 25 125 3/8" 8052957 SWD 20 1/4-14 x 2' TEKS 3 1477 (16 ga.) .060-16 ga - 3/16' 25 125 3/8 8055957 SWDR 1 1/420 xl TEKS 3 1900 (20 ga) 1500 1475 .036"-20 ga 3/16 25 125 4<8> 318" 8054957 SWDR 1-1/2 12-24 x 1-112" TEKS 5 2375 (3/16") 1500 1475 .188-3/16" 112" 25 125 3/8 8056957 SWDR 516 5/16-18 x 1 1/4 TEKS3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16 25 125 3/8" 8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16") .188-3/16" 112" 25 125 "Includes retaining nut & #14 Black Nut Driver - Part # aiioin Eliminates distortion of threaded rod in sloped roof applications. "Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. 'Allows 17° defection from vertical. Manufactured in the U.S.A. V/etch a video demnnstrassn at www.ghebuildex.com 3/8 8137957 SH-DSTR 1* 1 2368 (1/2 steel Vertical) I ' 318 8268957 SH-TEK 50 12-24 x 1-3/4" 1306(45° off Vertical) 1500 (Vertical) TEKS 5 2281 (3/160 HSS) 850 (45° off Vertical) J 1585 (3/16' HSS 45° off Vertical) I 2368 (1/20 steel Vertical) I 1/2' 8270957 SH-TEK 50 12-24 x 1-3/4' 1306)45° off Vertical) TEKS 5 2281 (3/160 HSS) #14 SN Orange 1585 (3/16 HSS 450 off Vertical) Nut Driver - - - - Part 4 8273910 Does not comply with ROHS requirements/Includes retaining nut SAul,Vi Y AX-PRESS® Installs into Metal Deck, Purl/n, or Tubular Steel 'I -- - ----. - The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8). Installs in seconds with Sammy X-Press Ite Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Manufactured in the U.S.A. 19 Watch a video demonstratioo at wwwitwbulldex.com 1/4" 8181922 XP 200 Sammy x-Press 00 1146 (22 9a) 185 (Luminaire) 250 (Luminalre) 850 (2W Pipe) 3/8" 8150922 XP 20 Sammy 1146(229a) '185 (Luminaire) X-Press 20 250 (Luminaire) 283 (Conduit & Cable) 1500(4" Pipe) r> 318" 8153922 XP 35 Sammy 1783 (16 gal 185 mu X-Press 35 250 (Luminaire) 416 (Conduit 6 Cable) if r€ 3/8850922XP20x,0 Sammy 1146(22gal 850(2A Pipe) - .125" 25 125 Metal Deck .027" 940 (2 Pipe) .029" 056" 1475 (4" Pipe) .104" .125" 25 125 Metal Deck .029" .060' .029" 940 (2" Pipe) .029" 25 125 Purlin .056" 1475 (4" Pipe) 1• .125 .059" Pre-Pour Structural Concrete@ 3000 psi Metal Deck 'Pre-Pour 25 Post-Pour Range II LWC 35 PCF (lbslW) 125 Metal Deck I Pre-Pour Structural Concrete @3080 psi Post-Pour Range II LWCS 35 PCF (lbs/W) *rjriH provide horizontal attachment in: - 16 ga - 3/16" steel - pudin, tubular steel. "Installs in seconds with Sammy X-Press It" Tool, The Sammy X-Press Sidewinder expands to saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof SWXP deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. "Manufactured in the U.S.A. I-Watce a video de,0000t,atioo at www.itwbulldex.comJ Sidewinder 1250 (3W Pipe) . 3/8" 8293957 SWXP35 1798)l6ga) 80 )Luminaire) .059" .125" 25 125 Purlin X-Press 35 -. - - 416 (Conduit & Cable) _ - Set Screw and Locknut Included 5tL- Beam Clamps TOLCOTM Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Size Range: Fig. 65 - 1/2".13 rod sizes, and 5/8"-1 1 rod sizes Fig. 65XT - /8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2"..13 rod will support thru 8" (200mm) pipe Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65_1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-/e /8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 65.1/2 11/4" (31.7) 55 (24.9) 65-/8 11/4" (31.7) 55 (24.9) TOLCOTM Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (lOomm) pipe. Designed to meet or exceed requirements of FM DS 2-0 and NFPA 13. 3/4" (19.0) liSTED APPROVED kji Set Screw and Locknut Included Part For Approx. W000 No. Rod Size Lbs. (kg) 65XT /8"-16 28.0 (12.7) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 14 B-Line series Fire Protection Solutions (22.2) (34.9) Fig. 69-/€-/2 Detail Beam Clamps à®us Usmu 7/,,,., TOLCOTM Fig. 69 - Beam Clamp Retaining Strap Size Range: I8'-16 thru /4'-1O rod 4" (1 01 .6mm) thru 16(406.4mm) lengtns Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut for the Fig. 69 or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed B-Line series or Tolco beam clamp. Finish: Pre-Galvanized Order By: Figure number, length (L), and finish. Note: Minimum return on strap is 1" (25.4mm). Lengths over 16" (406mm) are not UL Listed Part No. Hole Dia. D in. (mm) For Use With Length 133033-3/8, 133034-3/8, B3031-3/8, 69.3/8.1/2.1 see Detail A 65-3/8, 65XT-3/8, 66-/8 Specify 133033-1/2, 133034-1/2, 65-1/2, 66 1/2 69-/8-L 11/16" (17.5) B3033-5/8, 65-/8, 66-/8 Specify 69./4.L 13/16" (20.6) B3033-3/4 Specify All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 17 Eaton A-A Beam Clamps TOLCOTM Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: /8"-16 & 1/2'13 rod 4" (101,6mm) thru 16" (4064mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore the beveled locking slot of the Fig. 69R will provide a secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed B-Line series or Tolco beam clamp. Finish: Pre-Galvanized Order By: Figure number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) * Patent #5,947,424 Slot Width For Use With Length Part No. in. (mm) 69111-3/8-L /16" (11.1) 133033-3/8, 133034-3/8, Specify 65-/8, 65XT-3/8, 66-/8 69111-1/2-1. /16" 114.31 B3033-1 /2, 133034-1/2, 65 1/2, 66 1/2 Specify All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 18 B-Line series Fire Protection Solutions OO Fig. 65X1 Reversible Beam Clamp W-Beam Fig. 15 Swivel Attachment All Threaded Rod May be used with a pitched roof application, to meet requirements of NFPA 13 (2010-2016) Sec. 9.1.2.6. NI CPVC Clamps TOLCO Fig. 75 - Swivel Attachment Size Range: — /8-16 Rod Attachment Material: Steel Function: Three recommended applications for this product: May be used as a branch line restraint for structural attachment to anchor bolt, beam clamp, etc. May be used as an upper attachment with short hanger rod to omit seismic bracing. My be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2010) 9.1.2.6. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support up to 4)100mm) pipe. Finish: Electro-Galvanized Weight: Approx. Wt./100 - 13.3 Lbs. (6.0kg) Order By: Part number Patent: #7,887,248 Fig. 78 All Steel Ceiling Plate Fig. 75 Swivel Attachment Fig. 200 'Trimline Adjustable Band Hanger 3/t' All Threaded Rod Fig. 25 Surge Restrainer May be used as a structural attachment component of a branch line restraint ig. 75 Swivel Attachment All Threaded Rod B3100 Clevis Hanger May be used as a upper attachment with short hanger rod to omit seismic bracing All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in mil imeters unless otherwise specified. B-Line series Fire Protection Solutions 41 Eaton Function: Used as a spacer at a seismic brace location to keep clevis hanger from collapsing during seismic event. Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines OPM-0052-13, for 21/2 ' -8" (83100) only Installation Note: Fig. 1 CBS fits easily over the cross bolt and attaches by pinching tabs down. Finish: Pre-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number and finish. j. N Pipe Hangers TOLCOTM Fig. 1CBS - Clevis Bolt Spacer Size Range: Size 1' (25mm) thru 20' (500mm) clevis hanger OPM Material: Steel Part No. Pipe Size in. (mm) Approx. Wt./100 lbs. (kg) 1CBS-1 (25) 3.2 (1.4) 1CBS-11/4 11/4" (32) 4.1 (1.8) 1CBS-11/2 11/2" (40) 4.8 (2.2) 1CBS-2 (50) 9.4 (4.2) 1CBS-21/2 21/2" (65) 11.4 (5.2) 1CBS-3 (75) 13.9 (6.8) 1CBS-31/2 31/2" (90) 16.0 (7.2) ICBS-4 (100) 18.0 (8.1) 1CBS-5 (125) 27.3 (12.4) 1CBS-6 (150) 32.5 (14.7) 1CBS-8 8" (200) 42.5 (19.2) 1CBS-10 10" (250) 72.7 (32.9) 1CBS-12 12" (300) 86.3 (39.1) 1CBS-14 14" (350) 157.6 (71.5) 1CBS-16 16" (400) 183.7 (83.3) 1CBS-18 18" (450) 224.6 (101.9) 1CBS-20 20" (500) 254.0 (115.2) TOLCOTM Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4" (20mm) thru 2" (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2016 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2' (40mm). Patent #5,344,108 Approx. Wt./100 Part No. lbs. (kg) 25 4.8 (2.2) All dimensions in charts and on drawings are in inches. Dimensions shownin parentheses are in millimeters unless otherwise specified. Eaton Revised 8/8/2014 22 B-Line series Fire Protection Solutions Pipe Hangers TOLCOTM Fig. 200 - "Trimline" Adjustable Band Hanger TOLCOTM Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCOTM Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated TOLCOTM Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut (For sizes 1" thru 2") Size Range: A C@ us Zj' Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Overall Height USTED, APPROVED Material: Steel, Pre-Galvanized B Function: For fire sprinkler and other general piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. swivel nut design permits hanger adjustment after installation. 0 Top of pipe to bottom of hanger rod nut. Features: 1/2" (15mm) thru 2" (50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from . 200-' Fig. I2& 2OO-/4 abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes keep nut from separating with hanger. Hanger is easily installed ,. around pipe. 1/2" (15mm), 3/4" (20mm), and 21/2" (65mm( thru 8" (200mm)) Spring B tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. For 1/2" (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts order Fig. 200S . Fig. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) 0-21/2 to 200-8 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig. Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" )200mm)). 200-1 to .' Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 200-2 - and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F 1343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. 12 Order By: Part number and pipe size A. IL ** Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-1 V2 Or200M10-iV2 Fig. 200C Fig. 200F Fig. 200 Fig. 200& Fig. 200S 20OC11/2 shown 200E-11/2 shown shown with captured nut shown with 1" thru 2" sizes only non-captured nut Pipe Size Rod Size A B D Max. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200 1/2 1/2" (15) /8"-16 M8 or M10 31/8" (79.4) 2/8" (66.7) 111/32" (34.1) 400 (1.78) 11 (5.0) 200./4 , 3/4" (20) /8"-l6 M8 or M10 31/8" (79.4) 21/2" (63.5) 11/16" (27.0) 400 (1.78) 11 (5.0) 200-1 1" (25) /8"-16 M8 or M1O 3/8" (85,7) 2/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) /8"-16 M8 or M1C 33/4" (94.0) 2/" (73.0) 1/32" (29.3) 400 (1.78) 13 (5.9) - 200-11/2 11/2" (40) /811-16 M8 or MiD 37/8" (98.4) 2/8" (73.0) i/ie" (30.2) 400 (1.78) 14 (6.4) 200-2 2" (50) /811-16 M8 or MiD 41/2" (114.3) 3' (76.3) 1/16" (30.2) 400 (1.78) 15 (6.9) 200_2112 21/2" (65) /8°-16 M10 5/8" (142.9) 41/8' (104.7) 1/16" (36.5) 600 (2.67) 21 (12.3) 200-3 3" (75) 3/8 -16 M10 5/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) 200-31I2 31/2" (90) /8"-i6 M10 7/8" (187.3) 51/4" (133.3) 2/16" (55.6) 600 (2.67) 34 (15.6) 200-4 4" (1 00) /8"-16 MiO 7 /8" (187.3) 5" (127.0) i/" (34.9) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"13 M12 91/8" (231.8) 61/4" (158.7) 311/32" (84.9) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"_13 M12 101/8" (257.2) 6/4" (171.4) 2/32" (56.3) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"_13 M12 131/8" (333.4) 8/4" (222.2) 3/32" (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) B3205L - Threaded Rod (right & left hand threads) Size Range: I8'-16 thru /8"-9 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F 1399°Cl Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number, rod size, length and finish TI Specify Length TL Thread Size Standard Design Load Thread Size Thread Length TI 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-31e X 1 /8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 X 1/2"13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 X /8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 X 1 /4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 X 'L /811-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog AIR - All Threaded Rod - 120" (3.05m} Lengths TOLCOTM Fig. 99 - All Threaded Rod Cut To Length Size Range: 114"..20 thru /8"-9 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F 1399°Cl Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Order By: Figure number, rod size, length and finish Part No. - Size x length ATR Fig. 99 Threads Per Inch Recommended Load Lbs. (kN) Approx. Wt./100 Ft. Lbs. (kg) AIR /4" x 120 99-1I4" x length 20 240 (1.07) 12 (5.44) ATR 3/i" x 120 993/g" x length 16 730 (3.24) 29 (13.15) ATR /2° x 120 99-1I2" x length 13 1350 (6.00) 53 (24.04) AIR /8" x 120 99-/8" x length 11 2160 (9.60) 89 (40.37) AIR 3/4" x 120 993/4" x length 10 3230 (14.37) 123 (55.79) AIR /8" x 120 991/8" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 96 B-Line series Fire Protection Solutions 17 MI'Tom Powering Business Worldwide CLDP10 Load Distribution Plate Material - steel Increases ultimate uniform load capacity on DBE & DBR Series supports to 500 lbs. (2.22kN) UPC/Part # Cat. # Thickness Width Length Weight Each 782051 36110 CLDP10 11 Ga. (3.0mm) 1/8' (41mm) 9.5 (241mm) 0.53 (0.24kg) am DURA-BLOK rooftop solutions support ® DURA-BLOK' supports are made of 100% recycled rubber and are designed to provide an economical way to support pipes, HVAC systems, rooftop walkway systems, ducting, conduit, cable tray, and more. Made from 100% recycled 1" gap between blocks Dampens vibration For sloped roofs see rubber allows water to flow freely No need for supplemental adjustable hinge fitting Qualifies for LEED credits around longer assemblies rubber pad (13634) Reflective strip on both No roof penetration Will not float or blow away Open ends allows for sides allow for easy required LIV resistant easier adjustments to DBE, product visibility Product composition is not Suitable for any type DBR, and DBM series Channel is through sharp or abrasive; helping roofing material or other Drainage channel through bolted on all sizes for to extend the roof life flat surface center of block added strength Resistant to freeze/thaw Components & accessories Loosen hex nuts and slide Retighten the hex nuts with plate under the flat washers plate in place Compatible components BTS TN Nuts HHCS B22TH B22SH B634 B1%2400 B101 B104 BVT Series B2000 Series Series Series B218 B379 B219 Series B 79 B3126 Series See Eaton's B-Line series Strut Systems Catalog for more information. 2 EATON DURA-BLOK rooftop supports .. -.--..---- Rooftop applications RM DB Series Base with Galv. Channel - 1" (25mm) high Dimensions - 5" (127mm) High x 6" (152mm) Wide x Leng:h (overall length) Ultimate Load Capacity - (uniform load) * DB5 = 200 lbs. (0.89kN) DB30 = 1,500 lbs. (6,67kN) DB10 = 500 lbs. (2.22kN) DB40 = 2,000 lbs. (8.89kN) DB20 = 1,000 lbs. (4.45kN) DB48 = 2,500 lbs. (11.12kN) UPC/Part # Cat # Height Width Overall Length Weight Each 782051 50035 DB5 5' (127mm) 6" (152mn) 4.8" (122mm) 2.75 (1.25kg) 782051 49972 D1310 5" (127mm) 6" (152mm) .6' (244mm) 5.28 (2.39kg) 782051 49974 DB20 5" (127mm) 6" (152mm) 20.2" (513mm) 10.63 (4.82kg) 782051 50021 DB30 5" (127mm) 6' (152mm) 30.8" (782mm) 15.99 (7.25 kg) 782051 50022 DB40 5" (127mm) 6" (152mm) 41.4" (1052mm) 21.34 (9.68kg) 782051 50023 DB48 5' (127mm) 6" (152mm) 52.0" (1321 mm) 26.70 (12.4kg) DB6 Series Base with 12 ga. (2.6mm) Galv. Channel - 27Ae" (62mm) high Dimensions - 016" (163mm) High x 6" (152mm) Wide x Length (overall length) Ultimate Load Capacity - (uniform load) * DB610 = 500 lbs. (2.22kN) DB640 = 2,000 lbs. (8.89kN) DB620 = 1,000 lbs. (4.45kN) DB648 = 2,500 lbs. (11.12kN) DB630 = 1,500 lbs. (6.67kN) UPC/Part # Cat. # Height Width Overall Length Weight Each 782051 50024 DB610 016' (163mm) 6" (152mm) 9.6' (244mm) 6.36 (2.88kg) 782051 50025 DB620 6/i6' (163mm) 6" (152mm) 20.2" (513mm) 12.90 (5.85kg) 782051 50026 DB630 6/it' (163mm) 6" (152mm) 30.8' (782mm) 19.45 (8.82kg) 782051 50027 DB640 67A6" (163mm) 6" (152mm) 41.4" (1052mm) 26.00 (11.79kg) 782051 50028 DB648 6?/16" (163mm) 6' (152mm) 52.0' (1321mm) 32.55 (14.76kg) DB10 Series Two (2) Bases with 12 ga. (2.6mm) Galv. Channel - 1%" (41mm) high Dimensions - 67Ae" (143mm) High x 6" (152mm) Wide x Length (bridge length - see below) Ultimate Load Capacity - 1,000 lbs. (4.45kN) (uniform load) * ledividua Base UPC/Part # Cat # Height Length Bridge Length Weight Each 782051 50029 DB1O-28 5%" (143mm) 9.6" (244mm) 28" (711mm) 2.75 (1.25kg) 782051 50031 DB10-36 5%" (143mm( 9.6" (244mm) 36" (914mm) 5.28 (2.39kg) 782051 50032 D810-42 55/s" (143mm) 9.6" (244mm) 42" (1067mm) 10,63 (4.82kg) 782051 50033 DB1O-50 5%" (143mm) 9.6' (244mm) 50" (1270mm) 15.99 (7.25kg) 782051 50034 DB1O-60 5%" (143mm) 9.6' (244mm) 60" (1524mm) . 21.34 (9.68kg) DB10-36 * For Roof Loading, Consult Roofing Manufacturer or Engineer. As with most commercial roofs, the weakest point may be the insulation board beneath the rubber membrane. EATON DURA-BLOK rooftop supports 6 DB2318DS Duct supports DB_DS Series Two (2) Base Supports with Galv. Channel - 1" (25mm) high Dimensions - Height (overall) x Width (overall) x Length (overall) See table Riser Channels (SH Style) - 1%" (41mm) x 1%" (41mm) x 12 ga. (2.6mm) Fittings & Hardware - Electro-Plated Steel Ultimate Load Capacity - 1,000 lbs. (4.45kN) (uniform load)* UPC/Part # Cat # A (Minimum) A (Maximum) B Weight Each 782051 50717 DB2318DS 10.56 (268mm) 20.75 (527mm) 13.50 (343mm) 33.31 (15.11 kg) 782051 50718 DB2918DS 10.56" (268mm) 26.75" (679mm) 13.50" (343mm) 35.00 (15.88kg) 782051 50719 DB4118DS 10.56" (268mm) 38.75" (984mm) 13.50" (343mm) 38.40 (17.42kg) 782051 50720 DB5318DS 10.56" (268mm) 50.75" (1289mm) 13.50" (343mm) 41.80 (18.96kg) 782051 50721 DB2324DS 10.56" (268mm) 20.75" (527mm) 19.50" (495mm) 34.15 (15.49kg) 782051 50722 DB2924DS 10.56" (268mm) 26.75" (679mm) 19.50" (495mm) 35.84 (16.26kg) 782051 50723 DB4124DS 10.56" (268mm) 38.75" (984mm) 19,50" (495mm) 39.25 (17.80kg) 782051 50724 DB5324DS 10.56" (268mm) 50.75" (1289mm) 19.50" (495mm) 42.65 (19.34kg) 782051 50725 DB2336DS 10.56" (268mm( 20.75" (527mm) 31.50" (800mm) 35.84 (16.26kg) 782051 50726 DB2936DS 10.56" (268mm) 26.75' (679mm) 31.50" (800mm) 37.55 (17.03kg) 782051 50727 DB4136DS 10.56" (268mm) 38.75" (984mm) 31.50" (800mm) 40.95 (18.57kg) 782051 50728 DB5336DS 10.56" (268mm) 50.75" (1289mm) 31.50" (800mm) 44.34 (20.11 kg) 782051 50729 DB2348DS 10.56" (268mm) 20.75" (527mm) 43.50" (1105mm) 37.55 (17.03kg) 782051 50730 DB2948DS 10.56" (268mm) 26.75" (679mm) 43.50" (1105mm) 39.25 (17.80kg) 782051 50731 DB4148DS 10.56" (268mm) 38.75" (984mm) 43.50" (1105mm) 42.65 (19.34kg) .782051 50732 0B5348DS 10.56" (268mm) 50.75" (1289mm) 43.50" (1105mm) 46.03 (20.88kg) Cat. It Height (overall) Width (overall) Length (Overall) DB2318DS 23" (584mm) 251/B" (651 mm) 20.2" (513mm) D829180S 29" (736mm) 25W (651 mm) 20.2" (513mm) DB4118DS 41" (1041 mm) 251/s" (651 mm) 20.2" (513mm) DB53180S 53" (1346mm) 25W (651 mm) 20.2" (513mm) DB2324DS 23" (584mm) 31%" (803mm) 20.2" (513mm) DB2924DS 29" (736mm) 31W (803mm) 20.2" (513mm) DB4124DS 41" (1041 mm) 31W (803mm) 20.2" (513mm) DB5324DS 53 (1346mm) 31%" (803mm) 20.2" (513mm) DB2336DS 23" (584mm) 43%" (1108mm) 20.2" (513mm) DB2936DS 29' (736mm) 43W (1108mm) 20.2" (513mm) DB4136DS 41" (1041 mm) 431/8" (1108mm) 20.2" (513mm) DB5336DS 53" (1346mm) 43%" (1108mm) 20.2" (513mm) DB2348DS 23" (584mm) 551/8" (1415mm) 20.2" (513mm) DB2948DS 29" (736mm) 551/8" (1415mm) 20.2" (513mm) DB4148DS 41" (1041mm) 551/8" (1415mm) 20.2" (513mm) DB5348DS 53" (1346mm) 551/o' (1415mm) 20.2" (513mm) A = Adjustable height from bottom of DURA-BLOK" to top of horizontal channel. B = Space between fittings that support horizontal channel. Height (overall) = Distance from bottom of DURA-BLOK to top of upright channel. Width (overall) = Distance from outside-to-outside of DURA-BLOK supports. Length (overall) = Distance from end-to-end of DURA-BLOK supports. B+4.5"l114mml Height (overall) Width I (overall) DB5336DS ,(overall) Product is shipped unassembled. * For Roof Loading, Consult Roofing Manufacturer or Engineer. As with most commercial roofs, the weakest point may be the insulation board beneath the rubber membrane. 4 EATON DURA-BLOK rooftop supports I!! DBR1 0-12 DBE10-' Pipe supports - DBR Series Fixed Height Base with Galv. Channel - 1" (25mm) high and Pipe Roller Assembly Dimensions - Height to Bottom of Pipe x 6" (152mm) Wide x Long (length) - See Below Pipe Roller Material - Cast Iron - Electro-Plated Brackets, Axle & Hardware - Electro-Plated Steel Ultimate Load Capacity - (uniform load) * DBR2-31/2 = 500 lbs. (2.22kN) DBR12-14 = 1000 lbs. (4.40N) DBR4-6 = 500 lbs. (2.22kN) DBR16-20 = 1000 lbs. (4.40N) DBR8-10 = 1000 lbs. (4.44kN) UPC/Part # Cat. # Roller Part No! Height Width Length Weight Each 782051 50745 DBR2-31/2 B3126-2 to 31/2 7.09" (180mm) 6" (152mm) 9.6" (244mm) 5.28 (2.39kg) 782051 50746 DBR4-6 83126-4 to 6 7.09" (180mm) 6" (152mm) 9.6" (244mm) 10.63 (4.82kg) 782051 50747 DBR8-10 B3126-8 to 10 8.34" (212mm) 6" (152mm) 20.2" (513mm) 15.99 (7.25kg) 782051 50748 DBR12-14 B3126-12 to 14 8.34" (212mm) 6" (152mm) 20.2' (513mm) 21.34 )9.68kg) 782051 50749 DBR16-20 B3126-16 to 20 8.34" (212mm) 6' 152mm) 20.2" (513mm) 26.70 (12.11kg) DBR Series Adjustable Height Base with two (2)1/2"- 13' Electro Zinc All Threaded Rod Risers and a B3114-31/2" Pipe Roll with Sockets Dimensions - Overall Height as Specified Base -4" High (101mm) x 6" (152mm) Wide x 9.6" (244mm) Length (base length) Ultimate Load Capacity - 200 lbs. (0.89kN) * To increase load capacity use CLDP10 load distribution plate. UPC/Part # Cat. # Adjustable Height Width Length Weight Each 782051 50750 DBR1O-12 up to 12" (305mm) 6" 152mm) 9.6" (244mm) 6.46 (2.93kg) DBE Series Elevated Base with two (2) 1/2"13 Electro Zinc All Threaded Rod Risers and Galv. Slotted Channel -1" (25mm) high Dimensions - Overall Height as Specified Base -4" High (101mm) x 6" (152mm) Wide x 9.6" (244mm) Length (base length) Ultimate Load Capacity - 200 lbs. (0.89kN) * To increase load capacity use CLDP10 load distribution plate. For pipe straps/clamps, rollers and roller supports that can be used with these DURA-BLOK supports, see other components on page 2. UPC/Part # Cat. # Adjustable Height Width Channel Length Weight Each 782051 50036 DBE10-8 5½'-8" (140-203mm) 6" (152mm) 9.35" (161mm) 5.68 (2.58kg) 782051 50037 DBE10-12 5½" - 12" (140- 305mm) 6" (152mm) 9.35" (161mm) 5.72 (2.59kg) 782051 50038 DBE10-16 5½"- 16" (140-406mm) 6" (152mm) 9.35" (161mm) 5.76 (2.61 kg) Longer base lengths available Note: At heights above 12" (305mm), we suggest using the DB_DS Series Channel Support with Risers for additional stability to piping system f See Eaton B-Line series Pipe Hanger Catalog for dimensions and specifications. From bottom of DURA-BLOK" to bottom of pipe/tubing. * For Roof Loading, Consult Roofing Manufacturer or Engineer. As with most commercial roofs, the weakest point may be the insulation board beneath the rubber membrane. EATON DURA-BLOK rooftop supports Rooftop pipe supports DBM Series Base with one (1) %'-16 Electro Zinc All Threaded Rod and Hinged Pipe Clamp Dimensions -Height to Pipe Center x 6" (152mm) Wide x 4.8 (122mm) Long (overall length) Pipe Clamp Material - Malleable Iron Threaded Rod / Hardware - Electro-Plated Steel Ultimate Load Capacity - 50 lbs. (022kN) (uniform load) * Copper Tubing Supports UPC/Part # Cat # Clamp Part No.t Height (Min.)" Height (Max) Width Length Weight Each 782051 50733 DBM-Y2CT 93198HC1-1/2 9.69' (246mm) 11.19 (284mm) 6" (152mm) 4.80" (122mm) 2.75 (1.25kg) 782051 50734 I DBM-3/4CT B3198HC1-% 9.84' (250mm) 11.34 (288mm) 6' (152mm) 4.80 (122mm) 2.76 (1.25kg) 782051 50735 DBlVl-1CT B3198HCT-1 9.95" (253mm) 11.45' (291mm) 6" (152mm) 4.80" (122mm) 2.84 (1.29kg) 782051 50736 DBM-11/4CT 1331981-IC1-11A 10.13" (257mm) 11.63" (295mm) 6" (152mm) 4.80' (122mm) 2.95 (1.34kg) 50737 DBM-11/2CT B3198HC1-1½ 10.28" (261 mm) 11.78" (299mm) 6" (152mm) 4.80" (122mm) 2.96 (1.34kg) 4 782051 782051 50738 DBM-2CT B3198HC1-2 10.53" (267mm) 12.03" (305mm) 6' (152mm) 4.80" (122mm) 3.03 (1.37kg) DBM-2C Steel Pipe Supports UPC/Part # Cat. # Clamp Part No.t Height (Min.)**Height (Max)** Width Length Weight Each 782051 50739 DBM- '/2 B3198H- ½ 9.86" (250mm) 11.36' (288mm) 6' (152mm) 4.80 (122mm) 2.78 (1.26kg) J 782051 50740 DBM-% B3198H-3/4 10.05" (255mm) 11.56" (293mm) 6" (152mm) 4.80" (122mm) 2.84 (1.29kg) 782051 50741 DBM-1 B3198H-1 10.14" (257mm) 11.64' (296mm) 6' (152mm) 4.80" (122mm) 2.86 (1.30kg) 782051 50742 DBM-1'/4 133198H-11/4 10.25" (260mm) 11.75' (298mm) 6" (152mm) 4.80" (122mm) 2.93 (1.33kg) 782051 50743 DBM-11/2 63198H-11/2 10.42' (265mm) 11,92" (303mm) 6" (152mm) 4.80" (122mm) 2.99 (1.36kg) DBM-1 782051 50744 DBM-2 83198H-2 10.66 (271 mm) 12.16' (309mm) 6' (152mm) 4.80" (122mm) 3.10 (1.41 kg) Base only DURA-BLOKTM channel support is designed as an economical support for piping systems, cable tray, HVAC equipment and many other applications. See Eaton B-Line series Pipe Hanger Catalog for dimensions and specifications. From bottom of DURA-BLOK to bottom of pipe/tubing. * For Roof Loading, Consult Roofing Manufacturer or Engineer. As with most commercial roofs, the weakest point may be the insulation board beneath the rubber membrane. EATON DuRA-BLoK rooftop supports Dimensions - 4" (101 mm) High x 6" (152mm) Wide x 9.6' (244mm) Long (base length) Ultimate Load Capacity - (uniform load) * DBP - 500 lbs. (2.22kN) DBM - 200 lbs. (0.89kN) D OBP J*DBM UPC/Pa,t U Cat. U Height Width Length Weight Each 782051 49691 DBP 4" 001 mm) 6" (152mm) 9.6" (244mm) 4.48 (2.03kg) 782051 50005 DBM 4" (101 mm) 6' (152mm) 4.8" (122mm) 2.35 (1.07kg) Specifications PART 1 GENERAL 1.01 SECTION INCLUDES A. The work covered by this specification consists of furnishing all labor, equipment, materials and accessories, and performing all operations required for the correct installation of recycled rubber pipe [conduit] supports for mechanical piping [electrical conduit] systems. 1.02 REFERENCES ASTM A653 G90 SS Gr. 33 - Specification for Steel Sheet, Zinc Coated (Galvanized) by the Hot Dipped Process ASTM B633 - Specification for Electrodeposited Coatings of Zinc on Iron and Steel ASTM C531 -Test Method for Linear Shrinkage and Coefficient of Thermal Expansion of Chemical Resistant Mortars, Grouts, Monolithic Surfaces, and Polymer Concretes ASTM C642 - Test Method for Specific Gravity, Absorption, and Voids in Hardened Concrete ASTM C672 - Test Methods for Scaling Resistance of Concrete Surfaces Exposed to Deicing Chemicals ASTM D412 - Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension ASTM D395 - Standard Test Methods for Rubber Property - Compression Set ASTM D573 -Test Method for Rubber - Deterioration in an Air Oven ASTM D746 - Test Method for Brittleness Temperature of Plastics and Elastomers by Impact ASTM D2240 - Test Method for Rubber Property - Durometer Hardness NFPA 70- National Electrical Code 1.03 QUALITY ASSURANCE Rubber! steel pipe supports shall be manufactured under a strict quality control program assuring quality product delivered to the jobsite. Pipe supports that are damaged shall not be installed. Workmanship: All pipe [conduit] supports to be installed by a qualified piping [electrical] contractor and installed in accordance with manufacturer's recommendations. All work shall comply with all applicable federal, state, and local codes and laws having jurisdiction. All work shall conform to accepted industry and trade standards for pipe support [conduit] installations. PART 2 PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. Manufacturer: Subject to compliance with these specifications, pipe support systems shall be DURA-BLOK" design as supplied by Eaton [or engineer approved equal]. 2.02 MATERIALS Curb base must be made of 100% recycled rubber and polyurethane prepolymer with a uniform load capacity of 500 pounds per linear foot of support.* In addition, each base to have a reflective red stripe. (*See 3.01(C)) Dimensions: 6-inches wide by [4] [5.0] [6.75] inches tall by [9.6] [20.2] [30.8] [41.41 [52.0] inches long. Steel frame: Steel, strut galvanized per ASTM A653 or strut galvanized per ASTM A653 for bridge series. Attaching hardware: Zinc-plated threaded rod, nuts and attaching hardware per ASTM B633. Any products claiming to be a similar, like, or equal must demonstrate (meet or exceed) the same physical and performance characteristics as specified below: Density: 0.52 oz/cu in ASTM D575 Durometer Hardness: 67.2A ± I ASTM D575 Tensile Strength: 231 psi minimum ASTM D575 Compression Deformation: 5% at 70p5i and 72 F ASTM D575 Brittleness at Low Temp: -50 F ASTM D746 Weathering: 70 hours at 120 F ASTM D573 Hardness retained: 100% (±5%) Compressive strength: 100% (±5%) Tensile strength: 100% (±5%) Elongation retained: 100% (±5%) 2.03 TYPE OF ROOFTOP SUPPORTS Rubber block supports- DURA-BLOK"' model # [DBP] [DMBI base dimensions: 6-inch wide by 4-inch tall by 19.61 [4.8]-inch length. Accessories are fastened directly into rubber material with weather resistant type 12 lag screws. Continuous block channel supports - DURA-BLOK DB Series or DB6 Series: Dimensions 6-inch wide bt [5.0] [6.5]-inch tall bt [9.6) [20.21 [30.8] 141.41 [52.0]- inch length. Assembly has 1' gaps between blocks for free flow of water. Standard strut accessories can be used for attachment Bridge channel supports - DURA-BLOK DB1O Series; Dimensions 6-inch wide by 5% -inch tall by [28.0] [36.0] 142.01 150.01160.01-inch length. Standard strut accessories can be used for attachment Extendible height support - DURA-BLOK model DBE 10-[8][12][16], height to suit application: 8-inch, 12-inch or 16-inch 1200 pound maximum load). Base to be 9.6 inches in length or otherwise specified sizes available. Heavier loads, may require CLDP load distribution plate. Roller supports- DURA-BLOK DBR10 Series & DBR Series: DBR10 Series is sized for pipe up to 31/2 inches, with vertical adjustment up to 12 inches. DBR Series is sized for [2-31/2] [4-6] [8-10] [12-14] [16-201-inch pipe sizes. Elevated single pipe supports- DURA-BLOK DBM Series: [Copper] or [Steel] pipe sizes [½] [%] [1] [11/4] [11/z] [21-inch. PART 3 EXECUTION 3.01 INSTALLATION Install in accordance with manufacturer's instructions and recommendations. If gravel top roof, gravel must be removed around and under pipe support. Always consult roofing manufacturer for roof membrane compression capacities. If necessary, a compatible sheet of roofing material (rubber pad) may be installed under rooftop support to disperse concentrated loads and add further membrane protection. Gas pipe spacing subject to local gas authorities. Use properly sized clamps to suit pipe [conduit] sizes. EATON DURA-BLOK rooftop supports Eaton 1000 Eaton Boulevard Cleveland, OF-I 44122 United Staten Eaton .com © 2018 Eaton All Rights Reserved Printed in USA Publication No. BR300001EN June 2018 I15Ml BRTS-18 B-Line Division 509 Went Monroe Street Highland, IL 62249 Eaton .com Phone: 800-851-7415 Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow uses social media to get the latest product and support information. Powering Business Worldwide www.cooperbline.com/contactus