Loading...
HomeMy WebLinkAbout2674 GATEWAY RD; 190; FPC2020-0077; PermitIE1 11iIJl 1 11J.]!I eccity of Carlsbad Print Date: 10/20/2020 Permit No: FPC2020-0077 Job Address: 2674 GATEWAY RD, # 190, CARLSBAD, CA 92009-1785 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132622100 Track #: Applied: 04/20/2020 Valuation: $93,585.12 Lot #: Issued: 05/05/2020 Occupancy Group: Project #: Finaled Close Out: 10/20/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 1*: Inspector: Plan Check #: Final Inspection: Project Title: Description: TABU SI-IABU -ADD ONE DUCT DETECTOR TO SPRINKLER MONITORING PANEL FPContractor: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, # STE SAN DIEGO, CA 9212674458 (858) 752-6250 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE Sprinkler Monitoring $383.00 Total Fees: $576.00 Total Payments To Date: $576.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov SUBMITAL BOOK FOR: TABU SHABU 2674 GATEWAY RD. STE. 190 CARLSBAD, CA 92009 RIVER FIRE AND SECURITY 8920 ACTIVITY RD. STE. J SAN DIEGO CA 92126 C 1 896646 CUTSHEETS AND CSFM LISTINGS FOR: IDP-MINIMON 5/31/19 SILENT Farenhyt KNIGHT by Honeywell IDP-Minimon The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications UL Listed Installation The IDP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Agency Listings IDP-Minimon Compatibility The IDP-Minimon is compatible with the following FACPs: IFP-2000 / RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel lFP-1000 / ECS Intelligent Fire Panel IFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350279 Rev G Copyright © 2015 Honeywell International Inc Other Devices Wiring the IDP-Minimon Specifications Physical Height: 1.3' (3.3 cm) Width: 2.8" (7 cm) Depth: 0.5" (1.3 cm) Shipping Weight: 1.2 oz (37 g) Electrical Operating Voltage: 15 - 32 VDC SLC Standby and Alarm Current: 350 pA End-of-Line Resistance: 47K Q Initiating Device Circuit Wiring Resistance: 1,5000 max SLC Loop Resistance: 400- max. Wire Length: 6" mm. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Minimon Miniature Monitoring Module D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All KNIGHT specifications are subject to change without notice. For more information, contact S lent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203'1484-7118. by Honeywell For Tecnnical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, lDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, 5K-Mon-1 0, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and IDP-RELAYMON-2, *SKRELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division