HomeMy WebLinkAbout711 GRAND AVE; 1; FPC2020-0108; Permit(hty of Carlsbad liiliielBeTr1iflilt Print Date: 09/14/2020 Job Address: 711 GRAND AVE, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2033032113 Track #: Valuation: $104,522.80 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPC2020-0108 Status: Closed - Finaled Fixed Extinguishing Syste Applied: 06/22/2020 Issued: 07/31/2020 Finaled Close Out: 09/14/2020 Inspector: Final Inspection: Project Title: Description: HARUMAMA -AS- BUILTS FOR INSTALL NEW HOOD FIRE SYSTEM (APRVD AS-BUILT IN ATTACHMENTS) FPContractor: SAN DIEGO FIRE PROTECTION 1934 BONUS DR SAN DIEGO, CA 92110-1325 (619) 251-7241 FEE AMOUNT FIRE Hood & Duct Extinguishing System Initial Sys $417.00 Total Fees: $417.00 Total Payments To Date: $417.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Kitchen Mister Restaurant Cooking Area Fire Suppression System ... ..... TECHNICAL MANUAL Components Design Installation Maintenance Recharge Buckeye Fire Equipment BFR-TM 110 Kings Road ULEX 6885 ULC-EX 6885 Kings Mountain NC 28086 May 1, 2019 4.' I. • k -- \ ';•• (Ø ) 1• I Chapter 1 - General, Page 1 - Revisiofl 6 Chapter 1 General Information Introduction The Buckeye Fire Equipment Kitchen Mister Fire Suppression System is a pre-engineered wet chemical restaurant fire Euppression system as defined by the NFPA-17A Stardard for Wet Chemical Extinguishing Systems. It is designed to protect commercial restaurant cooking appliances, hoods, and ducts as described in this manual. Installation and maintenance of the Kitchen Mister System must be in comp'iance with the parameters set forth in this manual and be performed by a factory trained, Authorized Buckeye Fire Equipment Distributor. CAUTION This technical manua can in no way be conEidered sufficient to completely understand the proper design, installation, and/or maintenance of the Kitchen Mister System. Buckeye Certified Tra ning is required to become Authorized to perform these procedures. Buckeye Fire Equipment will iot be responsible for system(s) designed, installed, or maintained by individuals or companies not :rained and Authorized by Buckeye Fire Equipment. How the Kitchen Mister Works The Kitchen Mister System utilizes a potassium based liquid fire extinguishing age-it specifically designed for grease laden fires such as those associated with restaurant cooking areas. The Kitchen Mister açent works to suppress commercial kitchen fires in three ways: The agent interrupts the chemical chain reaction causing combustioi, thus extinguishing the fire. 2. The agent is dischargec in a very fine mist, cooling the fire to below its auto-ignition temperature. The agent reacts with grease to form a foam-like layer commonly called saponification that starves the fire of oxygen, stopping combustion and preventing re- ignition. The system will automatically actuate upon detection of a fire or can be manually actuated by using a remote manual pull station positioned at the point(s) of egress from the hazard area. When the system is actuated, a pre- determined anount of fire extinguishing agent is discharged through the piping network and fixed nozzles to the duct, plelum, and cooking appliances. The agent is discharged as a very fine mist that quickly acts to suppress grease laden fires. System Temperature Limitations The operating temperature range of the Kitchen Mister System is 32°F i0°C. minimum to 120°F (49°C) maximum. Listings and Approvals The Kitchen Mister Fire Suppression System is Listed and Approved by the following agencies: Underwriters Laboratories, Inc. (Listed to the requirements of UL-300/UL-1254) UL-EX 6885 Underwriters Laboratories of Canada, ULC-EX 6885 Approved by the New York City Fire Department COA # 5550 ISO-9001 Registered Manufacturer's Warranty Buckeye Fire Equipment warrants the Kitchen Mister System against defects in material and workmanship or a period of one year from date of shipment to the purchaser under normal use and service. Buckeye Fire Equipment is not responsible for the installation and maintenance of the system. All warranty claims must be filed with Buckeye Fire Equipment within 30 days of the discovery of the defect to be valid. System Installation and Maintenance Requirements Any individual installing or performing maintenance on the Kitchen Mister System MUST be; fully trained and Authorized by Buckeye Fire Equipment, have a complete understanding of this manual in full, and have a complete understanding of all local, state, and federaL requiremerts that may apply. The Buckeye Kitchen Mister System must be installed and maintained in accordance with the NFPA- I 7A Standard for Wet Chemical Extinguishing Systems, NFPA-96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, this manual, and all applicable local, state, and fedeal regulations. Buckeye Fire Equipment is not responsible for systems installed or maintained by personnel that are not factory trained and Authorized, BPN: BFR-TM ULEX 6885 ULC-EX 6835 May 1, 2019 Chapter 2 - Components Page 2 - 1 Revision 6 Chapter 2 System Components Cylinder Sizes The Buckeye Fire Equipment Kitchen Mister Fire Suppression System has available four (4) cylinder sizes; the Model BFR- 5 (5 flow points), Model BFR-10 (10 flow points), Model BFR-15 (15 flow points), and Model BFR-20 (20 flow points). Cylinder sizes are based on the flow point capacity of the cylinder, for example, the BFR-5 is capable of supporting a maximum of five (5) flow points. All cylinders are manufactured, marked, and tested in accordance with DOT 4BW240. Each cylinder is shipped pre-filled with extinguishing agent and charged with dry nitrogen to a pressure of 195 psig (1344 KPa) @700 F (21° C). Cylinder and valve assembly dimensions are shown in Figure 2-1. Note: Cylinders shall always be stored and installed in an upright position. Figure 2-1. Cylinder and Valve Assembly Dimensions. Model Number A inches (cm) B inches (cm) C inches (cm) D inches (cm) Max. Flow Points Weight lbs. (kg) Mounting Bracket BFR-5 24.8 (63) 16.2 (41) 10 (25) 13.4 (34) 5 42 lbs. (19) MB-1 BFR-10 34.4 (87) 25.8 (66) 10 (25) '23 (58) 10 74 lbs. (33) MB-2 BFR-15 44.8 (114) 36.2 (92) 10(25) 33.4 (85) 15 107 lbs. (48) MB-2 BFR-20 42.4 (108) 33.8 (86) 12 (31) 31 (79) 20 130 lbs. (60) MB-2 BPN: BFR-TM ULEX 6885 ULC-EX 6885 May 1, 2019 Systems Releasing Modules Systems Releasing Modules - Mechanical Model SRM2-M The Model SRM2-M Systems Releasing Module - Mechanical is a fully mechanical control head that can be used for system actuation. The Model SRM2-M can be connected directly to the cylinder valve or remotely to the system valve(s). The Model SRM2-M will support the following system inputs and outputs: One (1) Fusible Link Detection Line Mechanical Gas Valve(s) Mechanical Remote Pull Station(s) Up to four (4) sets of dry contacts Two windows in the front cover of the Model SRM2-M allow for visual verification of the actuation cartridge and the system status (SET/FIRED). See Figure 2-5. Clapte 2 - Components Page 2-3 Revision 6 S Figure 2.6. Model SRM-D, Systems Releasing Module-Duel Model SRM The Model SRM, Systems Re:easirg Module is a fully mechanical] control head tiat can be connected directly or remotely to the system valve and is required for system actuation. The Systems Releasing Module will support the following system inputs and outputs: One Fusible Link Detection Line One Gas Valve Line One Remote Pull Station Line Up to four (4) sets of dry contacts TWO windows in the front cover of the Model SRM allow for visual v&ification of the actuation cartridge presence and the system status (SET/FIRED). See Figure 2-7. Figure 2-5. Model SRM2-M, Mechanical Systems Releasing Module The Model SRM2-M can actuate a maximum of three (3) agent cylinders when using the Model BFR-AC-S Nitrogen Activation Cartridge (included with the SRM2-M) or five (5) agent cylinders when a Model BFR-AC-L Nitrogen Activation Cartridge is installed. Model SRM-D The Model SRM-D (Systems Releasing Module —Dual) is the same as the Model SRM except that it supports a second independent fusible link detection line. See Figure 2-6. EQUIPMENT SRM 0 9 8ET 0 L®,/' \ V SYSTEM STATUS INDICATOR \ACTUATION CARTRIDGE VIEWING WINDOW Figure 2-7. Model SRM, Systems Releasing Module BPN: BFR-TM ULEX 6815 ULC-EX 6885 May 1, 2019 Chapter 2 - Components Page 2-4 Revision 6 The Model SRM can actuate a maximum of three (3) agent cylinders when using the Model BFR-AC-S Nitrogen Activation Cartridge (included with SRM and SRM-D) or five (5) agent cylinders when a Model BFR- AC-L Nitrogen Activation Cartridge is installed. Systems Releasing Module(s) - Electric When utilizing electric detection, it is required that the SRM2-E be used with a Solenoid Monitor. If the detection circuit utilizes a 120-volt AC power source, the Model SRM2-E-120 must be used with a Model SM- 120 Solenoid Monitor along with a UL Listed 1A, 120VAC power supply (by others), in accordance with NFPA 17A, NFPA 96, and the local authority having jurisdiction. If the detection circuit utilizes a 24 VDC power supply, it is required that the Model SRM2-E-24 be used with a Model SM-24 Solenoid Monitor. The Model SRM2-E-24 requires a 24 VDC power supply with a minimum 2A rating. Model SRM2-E-24 The Model SRM2-E-24 Systems Releasing Module - Electric - 24 VDC, is an electrically (24-volt DC) operated control head that can be used for system actuation. The Model SRM2-E24 can be connected directly to the cylinder valve or remotely to the system valve(s). The Model SRM2-E-24 will support the following system inputs and outputs: Thermal (Electric) Detection Mechanical/Electrical Gas Valve(s) Mechanical Remote Pull Station(s) Up to four (4) sets of dry contacts Two windows in the front cover of the Model SRM2-E-24 allow for visual verification of the actuation cartridge presence and the system status (SET/FIRED). See Figure 2-8. The Model SRM2-E-24 can actuate a maximum of three (3) agent cylinders when using the Model BFR-AC-S Nitrogen Activation Cartridge (included with the SRM2-M) or five (5) agent cylinders when a Model BFR-AC-L Nitrogen Activation Cartridge is installed. Model SRM2-E-120 The Model SRM2-E-120 Systems Releasing Module - Electric - 120 VAC, is an electrically (120-volt AC/ 60 Hz) operated control head that can be used for system actuation. The Model SRM2-E-120 can be connected directly the cylinder valve or remotely to the system valve(s). The Model SRM2-E-120 will support the following system inputs and outputs: Figure 2-8. Model SRM2-E-24, BourEm SRM2-E-24 0 UT). —L FIRED Electric (24 VDC) Releasing Module Thermal (Electric) Detection Mechanical/Electrical Gas Valve(s) Mechanical Remote Pull Station(s) Up to four (4) sets of dry contacts Two windows in the front cover of the Model SRM2-E-1 20 allow for visual verification of the actuation cartridge presence and the system status (SET/FIRED). See Figure 2-9. SRM2-E-120 MD. 5 -L' FIRED 0. Figure 2-9. Model SRM2-E-120, Electric (120 VAC) Releasing Module The Model SRM2-M can actuate a maximum of three (3) agent cylinders when using the Model BFR-AC-S Nitrogen Activation Cartridge (included with the SRM2-M) or five (5) agent cylinders when a Model BFR-AC-L Nitrogen Activation Cartridge is installed. All Systems Releasing Modules use the same enclosure and have the same overall dimensions which are given in Figure 2-10. ULEX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2019 Nitrogen Actuation Cartridges The Kitchen Mister System can use two types of actuation cartridges for system actuation. Model BFR-AC-S is a small nitrgen cartridge (included with Systems Releasing Module(s)) that can actuate up to three (3) agent cylinders. Model BFR-AC-L is a larger nitrogen cartridge that can actuate up to five agent cylinders (refer to Chapter 4 of this manual for limitations). See Figure 2-17. 5.12 (13 cm) 01.57 IN Model BFR-AC-L 3.70 (9.4 cm) MO (2 01.00 .5 cm) Model BFR-AC-S Figure 2-17. Model BFR-AC-S and BFR-AC-L, Nitrogen Actuation Cartridges Mounting Brackets The Model MB-1 Mounting Bracket is used to mount the Model BFR-5 cylinder. See Figure 2-18. Figure 2-18. Model ME-I, Shown With BFR-5 Cylinder Chapter 2 - Components Page 2 - 7 Revision 6 The Model MB-2 Mounting Bracket is used to mount the Model BFR-10, Model BFR-I5, or Model BFR-20 cylinders. See Figure 2-19. - Figure 2-19. Model MB-2, Show With BFR-20 Cylinder Remote Mechanical Pull Stations The Model RPS-M Remote Mechanical Pull Station and Model RPS-M-RM Remote Mechanical Pull Station Recessed Mount provides remote mechanical actuation of the Systems Re easing Module(s). It is connected to the Systems Releasing Module(s) with: 1/16" (0.16 cm stainless steel cable enclosed in 1/2" (1.3 cm) EMT conduit with a corner pulley at each change of directici. Buckeye Shieldel Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. A remote pull statoi is required at. the point of egress from the hazard area being protected. See Figure 2-20 and Figure 2-21. 0 1 FIRE PULL HANDLE H.P.0 ACTU RPS—Mcjj C) 0 Figure 2-20. Model RPS-M, Remote Mechanical Pull Station BPN: BFR-TM ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 2 - Components Page 2 - 8 Revision 6 Figure 2-21. Model RPS-M-RM, Remote Mechanical Pull Station- Recessed Mount Mechanical Gas Shutoff Valves A gas shutoff valve is required for all systems protecting gas fueled appliances. A mechanical means of stopping gas flow is provided by the Models BFGV-75 /100/125! 150 / 200 /250 / 300 Gas Shutoff Valves. It is connected to the Systems Releasing Module(s) with: 1/16" (0.16 cm) stainless steel cable enclosed in 1/2" (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. The valves are rated for natural or LP gas (see Figure 2- 22) and are available in the following sizes: Model Number Valve Size In (cm) Maximum Operating Pressure BFGV-75 %(1.9) 5 psi (.4 bar) BFGV-100 1 (2.5) 5 psi (.4 bar) BFGV-125 1 ¼ (3.2) 5 psi (.4 bar) BFGV-150 1 ¼ (3.8) 5 psi (.4 bar) BFGV-200 2 (5.1) 5 psi (.4 bar) BFGV-250 2 1/2 (6.4) 5 psi (.4 bar) BFGV-300 3 (7.6) 5 psi (.4 bar) Note: Gas valve size must be no smaller than the size of the gas line it is connected to. 00 Figure 2-22. Model BFGV.XXX, Mechanical Gas Valve Fusible Link Bracket Kit The Model FLB-1 Fusible Link Bracket kit (see Figure 2- 23) includes the following: Standard high profile 10" (25 cm) fusible link bracket. Two (2) 1/2" (1.3 cm) EMT connectors. Two (2) cable crimps. Two (2) '5" hooks. Note: Fusible links must be ordered separately. FUSIBLE LINK BRACKET HOOK \ /2(1.3 cm) EMT J CONNECTOR CABLE CRIMP Figure 2-23. Model FL13-1, 10" (25 cm) Fusible Link Bracket Assembly Fusible Link Holder The Model FLH Fusible Link Holder is designed to allow for the use of a continuous fusible link line, thus eliminating the need to cut and Crimp each individual fusible link. They can be used either with or without fusible link brackets. They are available in packages of 25 (Model FLH-25). See Figure 2-24. 1116' 10.16 cm) STAINLESS DETECTION CABLE IBLE FU0lLL LINK (ML STYLE) Figure 2-24. Model FLH, Fusible Link Holder Buckeye Shielded Cable As an alternative to using conduit and corner pulleys to connect the fusible link system, gas valve, and/or remote pull station to the Systems Releasing Module(s), the Kitchen Mister System utilizes Buckeye Shielded Cable to perform this function. Buckeye Shielded Cable is 1/16" (0.16 cm) stainless steel cable encased in a protective, flexible conduit. See Figure 2-25. ULEX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2019 3/8" (1.0 cm) NPT FEMALE THREAD / 30" ROTATION 3/8" (1.0 cm) NPT MALE THREAD Buckeye Shielded Cable requires no conduit or corner pulleys, as the name implies, provided i: is installed in accordance with the guidelines set forth in this manual. Model BFR-SC-1 00 comes with 105 feet (:32 m) of flexible conduit with 210 feet (64 m) of 1/16(0.16 cm) stainless steel cable inside it. BUCKEYE Chapter 2 - Components Page 2 - 9 Revision 6 Each nozzle has a predetermined flow point value and comes equipped with a blow-off cap to protect the end orifice from blockage. Each nozzle is identified by the model number stamped on the nozzle body and has a unique color band for easy visual identification. See Figure 2-28. 1116 0.1 STAINLESS Figure 2-25. Model BFR-SC-100, Buckeye Shielded Cable Model Number Flow Points Band Color N-IHP 1 Blue N-1 LP 1 Red N-2HP 2 Green N-2LP 2 Yellow N-2W 2 White Shielded Cable Interface The Model BFR-SCI Buckeye Shielded Cable Interface is required for connecting Buckeye Shielded Cable to any standard 1/2" (1.3 cm) EMT conduit connector or corner pulley. See Figure 2-26. Figure 2-26. Model BFR-SCI, Shielded Cable Interface Note: A 3/32" (0.2 cm) hex wrench is required to tighten the set screw. Compression Type Corner Puley When Buckeye Shielded Cable IS NOT used to connect the fusible link system, gas valve, and/or remote pull station to the control head, a corner pulley is required whenever a change in stainless steel cable direction is necessary. The Model CPCT-1 corner pulley s quipped with a compression type fitting tha: connects to standard 1/2" (1.3 cm) EMT conduit. See Figure 2-27. Figure 2-27. Model CPCT-1, Compression Type Corner Pulley Discharge Nozzles Misting type discharge nozzles have been specifically developed for appliance, duct, and plenum applications. BPN: BFR-TM Note: Details on specific nozzle applications can be found in the Design Section of this manual. 13/16 TETHERED f BLOW-OFF CAP COLOR /0 BAND t p 1.10 g_P~C.EEN NTERNAL 3.8 cm) INING RING \_ 3/8 (1.0 Cr,,) NPT Figure 2-28. Discharge Nozzle Swivel Nozzle Adaptor The Model N-SA Swivel Adaptor can be used with any discharge nozzle to facilitate the nozzle aiming process. They are chrome plated and allow for a 300 rotation of the nozzle in any direction. See Figure 2-29. Figure 2-29. Model N-SA, Swivel Adaptor Pipe and Fittings Pipe and fittings must be furnished by the installer. Pipe shall be Schedule 40 black, chrome plated, or stainless- steel pipe. Fittings shall be rated 150 LB (68 kg). ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 - System Design Page 3 - I Revision 6 Chapter 3 System Design OVERVIEW OF SYSTEM DESIGN length and changes of direction with a maximum 50" (127 cm) perimeter and a maximum one side length of 12-1/2" The following chapter will cover the proper design of the (32 cm) (square) and 16-3/4" (43 cm) (rectangular) respectively. It can also protect a round duct with a Buckeye Fire Equipment Kitchen MisterFire Suppression maximum circumference of 50" (127 cm) [16" (41 cm) System. It is divided into three sections: maximum diameter]. See Figure 3-1 & 3-2. Nozzle Coverages and Placements Piping Limitations Detector Placement Design of the Kitchen Mister System must be in compliance with the parameters set forth in this manual and be performed by a factory trained, Authorized Buckeye Fire Equipment Dealer. Buckeye Fire Equipment is not responsible for systems installed or maintained by personnel that are not factory trained and Authorized. NOZZLE COVERAGE, PLACEMENT, AND AIMING This section will give detailed guidelines for determining nozzle type, positioning, and aim point for appliance, plenum, and duct protection. Ducts - 150" (381 cm) Maximum Perimeter Nozzle: N-2W (2 Flow Point) Coverage: Unlimited length with: 150" (381 cm) Maximum Perimeter with a longest side of 50" (127 cm) for rectangular ducts and 37-1/2" (95 cm) for square ducts or 150" (381 cm) Maximum Circumference [maximum diameter of 47-1/2" (121 cm)] for round ducts. Placement: Centered in duct opening, from 0-6" (0-15 cm) into the duct opening. Aim point: Center of duct. AIM: CENTER OF Duct Protection It is not necessary to shut down or damper the exhaust fan for the system to function properly. It is recommended that the exhaust fan be left on during system discharge to help distribute the extinguishing agent throughout the ductwork. Ducts - 50" (127 cm) Maximum Perimeter NOZZLE PLACEMENT: 1"- 6" (2.5-15 cm) 0 to 50" (0-127 cm), N-i LP] 0" -6" (0-15 cm) 0 to 150" (0-381 cm), N-2W] INTO THE DUCT Nozzle: N-1 LP (1 Flow Point) Coverage: Unlimited length with: 50" (127 cm) Maximum Perimeter with a longest side of 16-3/4" (43 cm) for rectangular ducts and 12-1/2" (32 cm) for square ducts or 50" (127 cm) Maximum Circumference (maximum diameter of 16" (41 cm)) for round ducts. Placement: Centered in duct opening, from 1-6" (2.5- 15 cm) into the duct opening. Aim point: Center of duct. The Model N-1 LP nozzle is a one flow point nozzle that can protect a square or rectangular duct of unlimited BPN: BFR-TM FOR DUCTS (VERTICAL OR HORIZONTAL) WITHOUT A TRANSITION AIM: CENTER OF ENTRANCE TO ID C HORIZONTAL DUCT NOZZLE PLACEMENT: 1-6(2.5-15cm) [Per. 0 to 50" (0-127 cm), N-1 LP] 0"- 6" (0-15 cm) 0 to 150" (0-381 cm), N-2 INTO THE DUCT TRANSITION FOR DUCTS WITH A VERTICAL TO HORIZONTAL TRANSITION Figure 3-1. Proper Duct Nozzle Placement ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 — System Design Page 3 — 2 Revisbn 6 FOR CIRCUM°ERENCES 0 to 50"(6- 127 mo): I MAXIMUM DL,METER SHALL NOT EXCEED - - , - - - -FOR CIRCUMFERENCES 0 to 150"(0-381 cm) NOZZLE TIF I, Jr USING THE P-2W: MAXIMUM DIAMETER CENTEREC. \ I SHALL NOT EXCEED 47-1/2" (121 em). AIMED INTO DUCT NOZZLE I' CENTERED, j NCZZLE TIP CENTEREC, AIMED INTO DUCTH I AIMED INTO DUCT 11 IN 11/2 -- - -- [_H1_1!2L F -1i2 FOR PERIMETERS 0 to 50" (6-127 cm): LONGEST SIDE SHALL NOT EXCEED 18-3/4' (42.5 cm); FOR PERIMETERS 0 to 150" (0-381 cm) USING THE N-2W: LONGEST SIDE SHALL NOT EXCEED 50" (127, cc'). VIEW OF DUCT CROSS-SECTIONAL AREA Figure 34. Froper Duct Nozzle Placement The Model N-2W nozzle is a two (2) flow point nozzle that can protect a square or rectangular duct of unlimited length and changes of directior, with a maxmum 150' (381 cm) perimeter and a maximum one side lergth of 37-1/2" (95 cm) (square) and 50" (127 cm) (rectangular) respectively. It can also protect a round cuct with a maximum circumference of 150' (381 cm) (47-1/2" (121 cm) rraxirnLm diameter). See Figure 3-1 and 3-2. Ducts Larger than 150" (381 cm) Perimeter For ducts with perimeters larger than 150' (381 cm), more than one Model N-2W nozzle must be used When using multiple Model N-2W nozzles to protect a single duct, the cross-sectional area of the duct must be divided into equal symmetrical areas. Each nozzle must then be instaled in the center of the area it is prctecting and aimed directly into the duct opening. No cross-sectional area can exceed the single nozzle coverage. Transition Ducts Protection of any non-standard duct should Le discussed and agreed upon with the local authority having jurisdiction before proceeding with any system inst3;1ation Typically, transition ducts are protected in the following manner. Larger to Smaller Duct Transitions To determine the proper coverage for ducts that have a Iarçer opening into the plenum than the final exhaust duct, meaSL re the perimeter of the duct half way between the: largest and smallest cross-sectional areas. The nozzle wili be located as per standard duct coverage at the duct'penum interface, rather than at the poim of measurement, and pointed into the duct, aimed at the center of the final duct opening. See Figure 3.3. HE PERIMETER /2 WAY INTO TRANSITION Figure 3.3. Proper Measurement and Nozzle Placement for Larger To Smaller Transition Ducts. Smaller to Larger Duct Transitions To determine the proper coverage for ducts that have a smaller opening into the plenum than the final exhaust duct, measure the perimeter of the final exhaust duct. The nozzle will be located as per standard duct coverage at the duct/plenum interface and aimed at the center of the duct opening. See Figure 3.4. PERIMETER._J MEASUREMENT Figure 3.4. Proper Measurement and Nozzle Placement for Smaller To Larger Transition Ducts. Upper! Lower Plenums Wnen protecting exhaust hoods with multiple risers (upper.' lower plenums), each riser must be protected as ar inoividual duct. See Figure 3.5. DUCT - PLENUM Figure 3.5. Upper! Lower Plenum Protection Electrostatic Precipitators Vent lation systems that utilize electrostatic precipitators requ re duct protection above and below the precipitator. Standard duct nozzles are used for this application. See Figure 3.6. I I Figure 3.6. Electrostatic Precipitator Protection. UL EX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2319 Plenum Protection Nozzle: N-I HP (1 Flow Point) Coverage: Length: 12 feet (3.7 m) max. Width: 4 feet (1.2 m) max. Placement: See Figure 3.7. Aim point: See Figure 3.7. The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a plenum (either single bank or V-bank) of 12 feet (3.7 m) in length and 4 feet (1.2 m) in width per nozzle. Larger plenums must be divided into 12-foot (3.7 m) sections, with each section protected with a separate nozzle. See Figure 3-7. Plenum: V-bank Nozzle Placement The nozzle must be located at the center of the V-bank width and down 1/3 of the vertical height, within 6 inches (15 cm) of the end of the plenum or plenum module and aimed down the length of the plenum. See Figure 3-7. Plenum: Single Filter Bank Nozzle Placement The nozzle must be located at a point that is 2" (5.1 cm) from the back edge of the filter and 1/3 of the vertical height of the filter, within 6 inches (15 cm) off the end of the plenum or plenum module and aimed down the length of the plenum. See Figure 3-7. 113H H V BANK 113H 12FT 12FT. H L.. MAX SINGLE BANK (3.7m) Vo Figure 3-7. Model N-IHP Plenum Nozzle Placement and Aiming Note: These examples are typical and do not represent every acceptable nozzle configuration, only a representative sample of them. DesignerNote For plenums that exceed 12 feet (3.7 m) in length and therefore require multiple nozzles, it is recommended that the total length be divided into equally sized protection zones and protected accordingly. So a 16 foot (4.9 m) long plenum should be divided into two 8 foot (2.4 m) zones, with a nozzle protecting each, as opposed to a 12 foot (3.7 m) zone and a 4 foot (1.2 m) zone. BPN: BFR-TM Chapter 3 - System Design Page 3 - 3 Revision 6 APPLIANCEPROTECTION Each different appliance must be protected in a specific manner with regard to nozzle selection, placement, and aiming. No deviations from these parameters are allowed and failure to comply completely with these requirements will void the UL Listing of the system and may render the system ineffective. In order to properly understand this section, several key terms need to be defined in advance. DESIGNTERMINOLOGY Nozzle Height: The distance from the tip of the discharge nozzle to the top surface of the appliance (except for woks, in which case the bottom of the wok is used). Hazard Area: All nozzle coverages include the maximum size of the hazard area they can protect. Hazard area is NOT the overall size of the appliance being protected, but rather the actual size of the portion of the appliance used for cooking. AppliancesRequiringMultipleNozzles Some appliances may need to be protected by multiple nozzles because of their size. If the size of an appliance is larger than the approved coverage for that appliance, multiple nozzles must be used. This is accomplished by dividing the hazard area into individual zones that comply with the parameters of the listing for that appliance. In this case, each zone will be protected as an individual appliance with respect to nozzle placement and aiming. RANGEPROTECTION Two (2) Burner Ranae - LOW Proximit Nozzle: N-1 LP (1 Flow Point) Coverage: 12" (30.5 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 16" (41 cm) —30" (76 cm) Placement: 3" (7.6 cm) from either edge of appliance, on appliance's long centerline. Aim point: 6" (15 cm) from opposite edge of appliance, on appliance's long centerline. The Model N-1 LP nozzle is a one (1) flow point nozzle that can protect a range cooking area of 12" (30.5 cm) wide by 24" (61 cm) deep. The nozzle must be located 16" (41 cm) to 30" (76 cm) above the cooking surface and positioned on the appliance's long centerline within 3" (7.6 cm) of either the front or back edge of the appliance. The nozzle must be aimed at the appliance's long ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 - System Design Page 3-4 Revision 6 centerline 6" (15 cm) off The opposite edge of the appliance. See Figure 3-8. MAXIMUM HEIGHT 30. 0 (16 mU NOZZLE PLACEMENT AREA (FRONT OR BACK OF APPLIANCE) MINIMUM HEIGHT AIM POINT 6 1 (4 RANGE >k: (IEU,,,) FROM OPPOSITE EDGE CENTER MNXIMUM ,,.,.FRONTOR BACK HAZARD 3 (I.E c,,,) FROM EOGE L 14:12 MAXMU( HAZUAC MDII: - 24 (El c,,,) Figure 3-8. Low Proximity, 12'(30.5 m) x 24" (61 cm) Range Model N-I LP Nozzle Four (4) Burner Ranges: 1) Four Burner Range - HIGH Proximity Nozzle: N-1 LP 1 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maimum (measured burier edge to Dumer edge) Nozzle Ht: 30" (76 cm) - 0" (102 cm) Placement: Within 3" (7.6 cm) of The certer of appliance. Aim point: Center of appliance. The Model N-1 LP n•Dzzle is a one (1) flow point nozzle that can protect a range cooking area of 24"(61 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface and within 3" (7.6 cm) of the center of the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-9. MAXIMUM I-EIGHT N .Ro,,) PL ROI 4U" JARiEA: NThR MINIMU '2)31.0 snl) ..6" BURNER TO BURNER BURNER TO LENGTH: BUFNER 24)61c m) WIDTH: 24" )''l cm' Figure 3-9. High Proximity, 24" (61 cm) x 24" (61 cm) Range Model N-ILP Nozzle 2) Four Burner Range - LOW Proximity Nozzle: N-2W (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximurr (measured burner edge to buner edge) Nozzle Ht: 16" (41 cm) - 30" (76 cm) Placement: Center of appliance. Aim point: Center of appliance. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a range cooking area of 24' (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 16" (41 cm) to 30" (76 cm) above the cooking surface and be centered over the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-10. MAXIMUM HEIGHT 30" (76 cm) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 16" (41 Cm) -lN, ,'- RANGE CENTER r- — BURNER TO 0 'lfr ,_- BURNER 0 BURNER TO BURIJEF LENGTH: WIDTH: 24" (61 cm) 24 (61 cm) Figure 3-10. Low Proximity, 24" (61 cm) x 24" (61 cm) Range Model N-2W Nozzle Six (6) Burner Range Nozzle: N-21-P (2 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 35" (89 cm) —43(109 cm) Placement: Centered over appliance. Aim point: Center of appliance. The Model N-2LP nozzle is a two (2) flow point nozzle that can protect a range cooking area of 36" (91 cm wide by 24" (61 cm) deep. The nozzle must be located 3" (89 cm) to 43" (109 cm) above the cooking surface and centered over the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-11. ULEX 6885 ULC-EX 6685 BPN: BFR-TM May 1, 2019 11(28cm) MAX." \ MAX. HEIGHT": 24" (61 cm)_ BIN. HEIGHT IS" (41 cm)..... 12 (3D m RANGE CENTER 15 IF SHELF IS HIGHER, THEN NOZZLE HEIGHT J MAY INCREASE PROPORTIONALLY. SHELF MAXIMUM MAYBE EXCEEDED IF NOZZLE lB' TIP IS PLACED BELOW (46 cm) SHELF HEIGHT, MIN. AIM: 6" (IS cm) FROM OPPOSITE EDGE, ON LONG CENTER LINE MAX. HAZARD NOZZLE LOCATED 3(7.6 LENGTH: 12" 35.8 cm) cm) FROM FRONT EDGE MAX. HAZARD WIDTH: 24" (61 cm) MAXIMUM HEIGHT 40" (109 cm) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 36" (90 cc,) ,- RANGE CENTER WIDTH: 24'(61 ~' j cm) Figure 3-11. 36" (91 cm) x 24" (61 cm) Range Model N-21LP Nozzle Chapter 3 - System Design Page 3 - 5 Revision 6 Protection For Appliances With a Back- shelf The protection of an appliance (such as a range) that has a shelf that can interfere with a nozzle discharge can be accomplished by either using the low proximity coverage for that appliance or placing the nozzle in a position within its stated limitation where the discharge pattern will not be affected. Sample coverages for a range with a back- shelf are shown in Figures 3-13 and 3-14. SHELF WIDTH: NOT TO EXCEED THE CENTERLINE OF THE RANGE UNLESS NOZZLE IS LOCATED UNDER SHELF OR OBSTRUCTION. NOZZLE -. MAX. HEIGHT: TIP LOCATED BELOW OR LEVEL PLACEMEN WITH THE BOTTOM OF THE OBSTRUCTION BUT '-CENTER OF NOT TO EXCEED 30' (76 cml MIN. HEIGHT 16" (41 cm) Ranqe I Griddle Combination ADDliance AIM: CENTER OF RANGE NOZZLE TIP MUST BE BELOW SHELF OR OBSTRUCTION. Nozzle: N-1 LP (1 Flow Point) Coverage: 30" (76 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm) —40" (102 cm) Placement: Within 3" (7.6 cm) of the center of appliance. Aim point: Center of appliance. The Model N-1 LP nozzle is a one (1) flow point nozzle that can protect a combination range / griddle with a cooking area of 30" (76 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface and within 3" (7.6 cm) of the center of the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-11. MAXIMUM HEIGHT 40" (102 cn,) NOZZLE (7.6 cm) PLACEM FRO AREA ENT CENTER MINIMUM HEIGHT 30176 cm) RANGE-GRIDDLE - . - CENTER BURNER - WIDTH: 12" 3 (30.5 cn,) MAX. (7.6 cccl - BURNER TO -. . BURNERIGRIDDLE BURNER TO GRIDDLE WIDTH. GRIDDLE WIDTH: 18"146 c "'"1 LENGTH: MAX. 30" (76 ) Figure 3-12. 30" (76 cm) x 24" (61 cm) Combination Range I Griddle Model NA LP Nozzle BPN: BFR-TM <30.5 6" 30.5 cm)) (15 cm).< (30.5 cm) , BURNER TO E BURNER TO R WIDTH: BURNER (61 cm) LENGTH 24" (61 cm) Figure 3-13. 24" (61 cm) x 24" (61 cm) Range with Back-shelf Model N-2W Nozzle Figure 3-14. 12" (30.5 cm) x 24" (61 cm) Range with Back-shelf Model WI LP Nozzle ULEX 6885 ULC-EX 6885 May 1, 2019 MAX. iII:II 9 (22.5 cm L ) BURNER EDGE TO BURNER ECOD: (15 CM) BURNER EDGE TO BURNER EDGE. 24 (RI n) (15 cm) 24(R1c,r( Chapter 3 - System Design. Page 3-6 Revision 6 Four Burner Range with a Back-shelf - HIGH Proximity Nozzle: N-2LP (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm) —40" (102 cm) Placement: 6" (15 cm) outside the front edge of the burners within 9" (22.6 cm) from the centerline. Aim point: 6" (15 cm) from the back edge of the burner on the centerline of the appliance. Shelf Height: Minimum of 16" (41 cm) from the top of the appliance. Shelf Width: A maximum of 11(28 cm). The Model N-2LP nozzle is a two (2) flow point nozzle that can protect a range cooking area of 24" 161 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface 6" (15 cm) from the fro-it edge of the burners and within 9" (22.5 cm) of the centerline of the appliance. The nozzle must be aimed 6" (15 cm) from the back edge of the burner on the centerline cf the appliance. The back shelf shall not be less than 16" (41 cm) from the top of the appliance and extend more than 11(28 cm) over the back edge of the burners. See Figure 3-14a. SHELF WIDTH : NOT TO EXCEED if (28 n1 MAX. HEIGHT: 40".102—) NOZZLE PLACEMENT AREA MIN. HEIGHT- 30' (76 cn) I AIM: 6 (15 6o) FROM BACKEDOE ON CENTERLINE Wok Protection Nozzle: W-1 HP (1 Flow Point) Coverage: 2" (30.5 cm) Min. x 30" (76 cm) Max. Nozzle Ht: 30" (76 cm) - 48(122cm) (measured from bottom) Placement: Anywhere over the surface of the appliance. Aim Point: Center of bottom of appliance. MAXIMUM HEI3HT NOZZLE AIMED ME .1 48" (122 cm) CENTER OF WOK B)TTOM NOZZLE PLACEMENT AREA 30"-(7'6 cm) MAXIMUM WOK DIAMETER: 30":76 cm) MINIMUM WOK DIAMETER: 12" (30.5 cm) Figure 3-14b. Wok Protecdon Model N-IHP Nozzle The Model N-1 HP nczzle is a one (1) flow point nozzle that can protect a wok with a minimum diameter of 12" (30.5 cm) up to a max mum diameter of 30" (76 cm). The nozzle must be located 30" (76 cm) to 48" (122 cm) above the bottom o the wok and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 344b. NIMUM SHELF HEIGHT 16'(41 cn) Figure 3-14a. 24" (61 cm) x 24" (61cm) Range with Back-shelf Model N-2LP Nozzle ULEX 6835 ULC-EX 6885 BPN: BFR-TM May 1, 2019 Deep Fat Fryer Protection Nozzle: N-2HP (2 Flow Point) Coverage: 20.25" (51 cm) x 24" (61 cm) Nozzle Ht: 24" (61 cm) - 45" (114 cm) Placement: Anywhere over the surface of the appliance cooking area. Aim point: Center of appliance. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a deep fat fryer with a maximum cooking area of 20.25" (51 cm) wide by 24" (61 cm) deep. The nozzle must be located 24" (61 cm) to 45(114cm) above the cooking surface and located anywhere over the appliance cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-15. Chapter 3 - System Design Page 3 - 7 Revision 6 Tiltina Brazina Skillet Protection Nozzle: N-2HP (2 Flow Point) Coverage: 20.25" (51 cm) x 24" (61 cm) per nozzle Nozzle Ht: 24" (61 cm) —45(114 cm) Placement: Anywhere over the surface of the appliance cooking area. Aim Point: Center of the protected zone. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a tilting brazing pan / skillet with a maximum cooking area of 20.25" (51 cm) wide by 24" (61 cm) deep per nozzle. The nozzle must be located 24" (61 cm) to 45" (114 cm) above the cooking surface and located anywhere over the appliance cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-16. MAXIMUM HEIGHT 45 (114 CM) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 24' (61 cm) NOZZLE TO BE LOCATED WITHIN THE PERIMETER OF THE HAZARD MAXIMUM HEIGHT 45" (114 cm) COVER MUST NOZZLE NOT INTEFERE PLACEMENT WITH NOZZLE AREA DISCHARGE MINIMUM HEIGHT 24 (61 cm) NOZZLE AIMED CENTER OF HAZARD AREA 7 MAXIMUM WIDTH: 24 (61 cm) MAXIMUM LENGTH: 20.25"(51 Figure 1-151 1-11 20.25" (cm) x 24" (cm) Deep Fat Fryer Model N-2HP Nozzle Fryers Requiring Multiple Nozzles Fryers that exceed the coverage of a single nozzle can be protected with multiple nozzles. The fryer must be divided into equal sized modules, so that each module does not exceed the maximum coverage allowed for a single nozzle. CAUTION The maximum size fryer that can be modularized is 864 square inches (5,574 sq. cm). Figure 3-16. Tilting Skillet! Brazing Pan Model N-2HP Nozzle GRIDDLE PROTECTION Standard Griddle: 42" (107 cm) x 30" (76 cm Nozzle: N-1 LP (1 Flow Point) Coverage: 42" (107 cm) x 30" (76 cm) Maximum Nozzle Ht: 24" (61 cm) —48" (122 cm) Placement: Directly over the edge of the cooking area. Aim Point: 6" (15 cm) from center of appliance in-line with the nozzle. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a griddle with a maximum cooking area of 42" (107 cm) wide by 30" (76 cm) deep. The nozzle must be located 24" (61 cm) to 48" (122 cm) above the cooking surface and positioned directly above the edge of the cooking area. The nozzle must be aimed 6" (15 cm) from the center of the cooking area in-line with the nozzle. See Figure 3-17. BPN: BFR-TM ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 - System Design Page 3 - 8 Revision 6 NOZZLE TO BE LOCATED ON THE PEF:IMETEROF The Model N-ILP nozzle is a one (1) flow point nozzle MAXIMUM HEIGHT I THE HAZARC 48(122cm) I that can protect a griddle with a maximum cooking area of 48" (122 cm) wide by 30" (76 cm) deep. The nozzle 7 NOZZLE - must be located 30" (76 cm) to 43" (109 cm) above the PLACEMENT - AREA -- - cooking surface, on the centerline of the appliance and 6" (15 cm) off the either short edge. The nozzle must be I MINIMUM HEIGHT aimed 3" (7..6 cm) from the center of the cooking area in- 24(61 cm line with the nozzle. See Figure 3-18. I Extra Large Griddle - 60" (152 cm) x 30" I NO ZLE AIMED 115 (76 cm) I -_ FF.OM CENT R - OF5AZARDAR -< Nozzle: N-2LP (2 Flow Point) INLINE SMTh NOZZLE > MAXIMUM 15 cm) Coverage: 60" (152 cm) x 30" (76 cm) Maximum LENGTH: 42" (107 cm) MAXIMUM 30" (76 cm) - Nozzle Ht: 24" (61 cm) —48" (122 cm) Placement: Directly over the edge of the cooking area. Figure 3-17. Standard Griddle: 42" (107 cm) x 30" (76 cm) Aim Point: 8" (20 cm) from center of appliance in-line Model N-I LP Nozzle with the nozzle. Large Griddle - 48" (122 cm) x 30" (76 cm) Nozzle: N-1 LP (1 Flow Point) Coverage: 48" (122 cm) x 30" (76 cm) Maximum Nozzle Ht: 30" (76 cm) —43" (109 cm) Placement: On the centerline of the appliance, 6" (15 cm) off the short edge. Aim Point: 3" (7.6 cm) from center of appliance in-line with the nozzle. MAXIMUM HEIGHT 43(109cm) NOZZLE / PLACEMENT / AREA 'j W:IN MUM HEIGHT (76 cm) /76cm) MAXIMUM LENGTH: rMAXIMUM -' WIDTH: -30" (76 cm) Figure 3-18. Large Griddle: 48" (122 cm) x 30" (76 cm) Model N-ILP Nozzle The Model N-2LP nozzle is a two (2) flow point nozzle that can prDtect a griddle with a maximum cooking area of 60" 152 cm) wide by 30" (76 cm) deep. The nozzle must be located 24" (61 cm) to 48" (122 cm) above the cooking surface and positiored directly above the edge of the cooking area. The nozzle must be aimed 8" (20 cm) from the center of the cooking area in-line with the nozzle., See Figure 3-19. / I NOZZLE TO B HAZ E LOCATED ON MAXIMUM HEIGHT THE PERIMETER OF THE 48" (122 cm) HAZARD NOZZLE PLACEMENT AREA MMHGHT j NOZZLE AIMED 8' FROM CENTER OF HAZARD AREA INL)NE.MTH NOZZLE MAXIMUM MAX LENGTH. 60" IMUM 30 (152 cm).. " (76 cm) Figure 3-19. Extra Large Griddle: 60" (152 cm) x 30" (76 cm) Model N-2LP Nozzle ULEX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2019 Extra Low Proximity Griddle Nozzle: N-2W (2 Flow Point) Coverage: 42" (107 cm) x 30" (76 cm) Maximum Nozzle Ht: 2" (5 cm) - 10" (25 cm) Placement: Over any corner, at a 450 angle to the surface. Chapter 3 - System Design Page 3 - 9 Revision 6 of 60" (152 cm) wide by 30" (76 cm) deep. The nozzle must be located 10" (61 cm) to 30" (122 cm) above the cooking surface and positioned 0" to 3" (7.6 cm) outside the short side edge of the cooking area of the griddle. This allows the nozzle to be placed anywhere over the short edge and up to 3(7.6 cm) outside of the short edge of the appliance. The nozzle must be aimed at the point one-quarter the longest side length (1/4L) from the griddle short edge, in-line with the nozzle. See Figure 3- 19b. Aim Point: At cooking surface, equal distance from MAXIMUM OF 3' (7.6cm) FROM EDGE/,/ both edges. The Model N-2W nozzle is a two (2) flow point nozzle MAXIMUM HEIGHT 30' (76 cm) that can protect a griddle with a maximum cooking area of 42" (107 cm) wide by 30" (76 cm) deep. The nozzle NOZZLE must be located 2" (5 cm) to 10" (25 cm) above any PLACEMENT AREA I corner of the cooking surface and positioned on the edge of the cooking area of the griddle. The nozzle must be MINIMUM HEIGHT aimed at the point over the cooking surface equal 10" (25 cm) distance from both edges. See Figure 3-19a. -.-.-. 1/4 L MAXIMUM HEIGHT I 10" (25 cm) MAXIMUM NOZZLE LENGTH)L): 60" (152 cm) I MAXIMUM PLACEMENT WIDTH: 30" (76 cm) AREA MINIMUM HEIGHT 2(5cm) Figure 3-19b. 60" (152 cm) x 30" (76 cm) Griddle Model N-2W Nozzle MAXIMUM WIDTH: 30" (76 cm) MAXIMUM LENGTH(L): 42' (107 cm) CHARBROILER PROTECTION Radiant Charbroiler Figure 3-19a. 42" (107 cm) x 30" (76 cm) Griddle Model N-2W Nozzle Low Proximity Griddle Nozzle: N-2W (2 Flow Point) Coverage: 60" (152 cm) x 30" (76 cm) Maximum Nozzle Ht: 10" (25 cm) —30" (76 cm) Placement: From 0" to 3" (7.6 cm) outside the short side edge of the cooking area, Aim Point: One-quarter the length (1/4L)of the longest side, in-line with the nozzle. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area Nozzle: N-1 HP (1 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum Nozzle Ht: 30" (76 cm) —48" (122 cm) Placement: Anywhere over the surface of the appliance. Aim Point: Center of appliance. The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a radiant charbroiler with a cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 48" (122 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-20. BPN: BFR-TM ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 -System Design Page 3 - 10 Revision 6 NOZZLE TO BE LOCATED WITHIN MAXIMUM HEIGHT ,. 48(122cm) THE PERIMETER OF THE HAZARD NOZZLE - PLACEMENT AREA MINIMUM HEIGHT 30" (76 NC LE A. MED CENTER OF - HZAFC MREA - LENGTH: 36 )9 cmi- T -J- WIDTH: 24 (61 cm) Figure 3-20. Radiant Charbroiler Model N..IHP Nozzle Lava Rock Charbroiler Protection Nozzle: N-2HP (2 Flow Point) Coverage: 24" (.1 cm) x 24" (61 cm) Maximum Nozzle Ht: 24" (61 cm) - 40" (102 cm) Placement: Anywhere oer the surface of the a 3lince. Aim Point: Center of apliance. The Model N-2HF nozzle is a two (2) flow point nozzle that can protect a java rock charbroiler with a cooking area of 24" (61 cm) vide by 24" (61 cm) deep. The nozzle must be located 24' (61 cm) to 40" (102 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-21. NOZZLE TOBE LOCATED WITHIN I THEPERIMETEROF I THE HAZARD MAXIMUM HEIGHT 40" (101 cm) NOZZLE -" PLACEMENT AREA -- MINIMUM HEIGHT 24' (61 cm) MAXIMUM WIDTH: 24" (61 :m) I CE'T8R OF HZ.ERl AREA LENGTH: 24' (61 cm_f ..__ Figure 3-21. Lava Rock Charbroiler Model N-2HP Nozzle Upright Broiler Protection Nozzle: N-1 LP ( Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum Nozzle Ht: Upper corner of broiling chamber. Placement: Positioned in the corner of the front opening of the appliance. Aim Point: Center cf cooking grate. - The Model N-1 LP nozzle is a one (1) flow point nozzle that can protect an upight broiler (sa amander broiler) with a cooking area of 36" (91 cm) woe by 24" (61 cm) deep. The nozzle must be located in the top front corner of the broiler and aimed at the center of the cooking grate. See Figure 3-22. ULEX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2019 Chapter 3 - System Design Page 3-11 Revision 6 NOULO AIMED AT CENTER OF COOKING GRATE Appliances Requiring Multiple Nozzles (Module Protection) Appliances that exceed the coverage of a single nozzle can be protected with multiple nozzles. The appliance hazard area must be divided into equal sized modules with each module not exceeding the maximum coverage allowed for a single nozzle. Each nozzle is then located and aimed within the module it is protecting, following the limitations stated for single nozzle coverage. See Figure 3-24 for an example of module protection. Figure 3-22. Upright Broiler 36" (91 cm) x 24" (61 cm) Model N-I LP Nozzle Class "A" (Solid Fuel) Charbroiler Protection Nozzle: N-2HP (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum Nozzle Ht: 24" (61 cm) - 40" (102 cm) Placement: Anywhere over the surface of the appliance. Aim Point: Center of appliance. Fuel Depth: 6" (15 cm) Maximum The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a Class A" (solid fuel) charbroiler with a cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 24" (61 cm) to 40" (102 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-22a. / NOZZLE TO BE LOCATED WITHIN I THE PERIMETER OF I THE HAZARD MAXIMUM HEIGHT NOZZLE PLACEMENT AREA MINIMUM HEIGHT 24" (61 cm) MAXIMUM WIDTH: 24" (61 LENGTH: 24" (61 cn Figure 3-22a. Class "A" (Solid Fuel) Charbroiler Model N-2HP Nozzle CAUTION The maximum size fryer that can be modularized is 864 square inches (5,574 sq. cm). NOZZLE TO BE LOCATED WITHIN THE PERIMETER OF MAXIMUM HEIGHT THE MODULE 40" 122 cm) THE NOZZLE PLACEMENT NOZZLE TO BE AREA LOCATED WITHIN HE PERIMETER OF WfUMUM-REIGHT— THE MODULE 30" (76 cm) WIDTH: 2 CENTER OF MODULE CENTER OF MODULE 60" (152 cm) Figure 3-24. Sample Radiant Charbroiler Module Protection BPN: BFR-TM ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 - System Design Page 3 - 12 Revision 6 COVERAGE SUMMARY TABLE COVERAGE COLOR FLOW NOZZLE HT. PLACEMENT AIMING APPLICATION NOZZLE PAGE Inches (cm) BAND POINT Inches (cm) Inches (cm) Inches (cm) DUCT, RECTANGLE UP TO 50 (127) PER.; MAX. N-1LP RED 1 1-6 (2.5-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 SIDE OF 16-3/4(43) DUCT OPENING DUCT, SQUARE UP TO 50 (127) PER.; MAX. N-1LP RED 1 1-6 (2.5-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 SIDE OF 12-1/2(32) DUCT OPENING DUCT, ROUND UP TO 50 (127) CIRCUM N-1LP RED 1 1-6 (2.5-15) INTO CENTERED IM DUCT CENTER OF DUCT 3-1 [16 (41) DIA.] DUCT OPENING DUCT, RECTANGLE UP TO 150 (381) PER.; N-2W WHITE 2 0-6 (0-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 MAX. SIDE OF 50 (127 DUCT OPENING DUCT, SQUARE UP TO 150 (381) PER.; N-2W WHITE 2 0-6 (0-15) INTO CENTERED If DUCT CENTER OF DUCT 3-1 MAX. SIDE OF 37-1/2(95) DUCT OPENING DUCT, ROUND UP TO 150 (381) CIRCUM N-2W WHITE 2 0-6 (0-15) INTO CENTERED WDUCT CENTER OF DUCT 3-1 [47-1/2(121) DIA] DUCT OPENING PLENUM, SINGLE 12 FT (3.7 m) IN LENGTH; N-1 HP BLUE 1 1/3 H FROM TOP; 2(5) IN FROM 0-6(0-15) FRCM END OPPOSITE END OF 3-3 BANK 4FT(1.2m)IN WIDTH FILTER BOTTOM PLENUM PLENUM"V"- BANK 12 FT (3.7 m) IN LENGTH, N-1HP BLUE 1 1/3 H FROM TOP; 0-6 (0-15) FROM END OPPOSITE END OF 3-3 4FT(1.2m)IN WIDTH 1/2W PLENUM RANGE, TWO- * 3(7.6) FROM FRONT OR 6(15) FROM BURNER 12(30.5) X 24 (61) N-1LP RED 1 16 (41) -30(76) BACK EDGE ON CLINE OPPOSITE EDGE ON 3-3 (Back-shelf) * CLINE RANGE, FOUR- 24 (61)X 24 (61) N-ILP RED 1 30(76)-40(102) WITHIN 3(76) 0 CENTER OF 3-4 BURNER CENTER APPLIANCE RANGE, FOUR BURNER- LOW 24 (61)X 24 (61) N-2W WHITE 2 16(41)-3D (76) * CENTER OF APPLIANCE CENTER OF 3-4 PROXIMITY APPLIANCE (Back sheIf)* RANGE, SIX-BURNER 36 (91) X 24 (61) N-2LP YELLOW 2 35 (89) -43(109) CENTER OF AFPLIANCE CENTER OF APPLIANCE 3-4 RANGE/GRIDDLE 30 (76)X 24 (61) N-1LP RED 1 30(76)-40(102) WITHIN 3(76) OF CENTER OF 3-5 COMBINATION CENTER APPLIANCE RANGE, FOUR BURNER w/B SHELF - 24 (61)X 24 (61) N-2LP YELLOW 2 30 (76) -40(102) 6)15) OFF FRONT 6(15) from BACK 3-6 HIGH _PROXIMITY EDGE EDGE WOK 12(30.5)TO3O)76)DIA. N-1HP BLUE 1 30(76)-48(122) ANYWHERE OVER BOTTOM CENTER 3-6 HAZARD AREA DEEP FAT FRYER, 20.25(51)X24(61) N-2HP GREEN 2 24(61)-45(114) ANYWHERE OVER CENTER OF 3-7 SINGLE VAT HAZARD AREA APPLIANCE TILTING SKILLET, 20.25(51)X24(61) N-2HP GREEN 2 24(61(-45(114) ANYWHERE OVER CENTER OF 3-7 BRAISING PAN HAZARD AREA** APPLIANCE GRIDDLE, 42 (107)X 30 (76) N-1LP RED 1 24(61)- 48 (122) DIRECTLY OVER EDGE 6(15) FROM CENTER, IN-LINE 3-7 STANDARD OF HAZARD AREA WITH NOZZLE 6 (15) OUTSIDE OF 3(7.6) FROM GRIDDLE, LARGE 48 (122) X 30 (76) N-1LP RED I 30(76)-43(109) SHORTER EDGE OF HAZARD AREA ON CENTER, IN-LINE 3-8 CLINE WITH NOZZLE GRIDDLE, EXTRA 60 (152) X 30 (76) N-2LP YELLOW 2 24(61)- 48 (122) DIRECTLY OVER EDGE 8(20) FROM CENTER, IN-LINE 3-8OF LARGE HAZARD AREA WITH NOZZLE GRIDDLE, OVER ANY CCRNER AT AT COOKING STANDARD, EXTRA 42 (107) X 30 (76) N-2W WHITE 2 2 (5)-ID (25) A 450 ANGLE TO SURFACE, EQUAL 3-9 LOW PROXIMITY COOKING SURFACE FROM EDGES GRIDDLE, LOW 0 1o3" (7.6 cm) ouside 1/4 Length of the PROXIMITY 60 (152) X 30 (76) N-2W WHITE 2 10 (25) -30(76) the short sice edge longest side, in-line 3-9 with _the _nozzle CHARBROILER, 36 (91) X 24 (61) N-1HP BLUE I 30(76)-48(122) ANYWHERE OVER CENTER OF 3-9 RADIANT HAZARD AREA APPLIANCE CHARBROILER, LAVA 24(61)X24(61( N-2HP GREEN 2 24(61)-40(102) ANYWHERE OVER CENTER OF 3-10 ROCK HAZARD AREA APPLIANCE CHARBROILER, UPPER CORNER FRONT CORNER OF CENTER OF UPRIGHT 36 (91) X 24 (61) N-ILP RED 1 OF BROILING OPENING TO BRCILER COOKING GRATE 3-11 (SALAMANDER) CHAMBER CHAMEER CHARBROILER, 24(61)X24)61) N-2HP GREEN 2 24(61)-40(102) ANYWHERE OVER CENTER OF 3-11 CLASS A" HAZARD AREA APPLIANCE * Coverages can be used when a range with a back-shelf or other type of obstruction, as long as the discharge pattern is not affected, ** Cover must not interfere with nozzle discharge. For the High Proximity Back-shelf coverage the shelf shall not exceed more than 11" (28 cm) over the back edge 01 the burners and be a minimum of 16" (41 cm) from the top of the appliance. ULEX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2019 Chapter 3 - System Design Page 3 - 13 Revision 6 PIPING LIMITATIONS This section contains detailed piping limitations that are necessary to design the piping network for The Buckeye Fire Equipment Kitchen Mister Fire Suppression System. Because the system is of the pre-engineered type, maximum and minimum piping parameters have already been established for each cylinder size. No variations to these limitations are allowed under the UL Listing. The maximum and minimum pipe length for each size agent cylinder is based on total internal pipe volume, regardless of the diameter of the pipe used. All piping parameters are based on total system piping and do not make a distinction between branches and supply line piping. Note: Pipe and fittings must be furnished by the installer. Pipe shall be Schedule 40 black, chrome plated, or stainless-steel pipe. Fittings shall be rated 150 lb (68 kg). PIPING VOLUME CHART Allowable Volume Pipe Sizes Per foot 3/8 in. (17.1 mm OD) 37.5 mL./ft. (123mL/m) pipe 1/2 in. (21.3 mm OD) 59.8 mL./ft. (196mLJm) pipe Example: 20 feet (6.1 m) of 3/8" (17.1 mm OD) pipe is equal to 750 mL. of pipe volume [20 ft. (6.1 m) X 37.5 mLift. (123mLJm) = 750 mL.). MAXIMUM PIPING PER CYLINDER SIZE Max. Max. Pipe Max. Pipe Cylinder Flow Volume Vol. Between Size Points (mL.) any two (2) Nozzles. (mL.) BFR-5 5 1500 1000 BFR-10 10 2500 2000 BFR-15 15 2800* 2500 BFR-20 20 2800* 2500 * Total volume of 3/8" (17.1 mm OD) piping allowed on the BFR-15 or BFR-20 is 2500 mL. Minimum Piping Requirements Note: Minimum piping requirements ONLY apply when protecting a wok, deep fat fryer, or range. Minimum number of elbows before the closest nozzle protecting a fryer, range, or wok shall be five (5). The minimum piping volume before the closest nozzle protecting a fryer, range, or wok shall not be less than 360 mL. The total system pipe volume shall not be less than 660 mL. for all cylinder sizes. A system shall have a minimum of three (3) flow points. General Piping Requirements All piping must be either 3/8" (17.1 mm OD) or 1/2" (21.3 mm OD). The maximum number of elbows allowed per system are: BFR-5: 20 elbows maximum BFR-10/15/20: 25 elbows maximum The maximum number of elbows between any two nozzles is five (5). The maximum vertical rise of the supply line is 10 feet (3 m), this is either the maximum elevation difference between tank outlet and the highest nozzle or tank outlet and the highest or lowest point in the piping system. The maximum vertical rise of any nozzle above the supply line is 2 feet (0.6 m). No traps are allowed in the piping system. Note: A trap" is defined as a section of pipe that would allow liquid to accumulate, such as, either a low point in the piping layout or piping that extends past the last discharge point. When different sized piping is used in the same system, the largest diameter pipe must be closest to the cylinder and sizes are to decrease as they reach the nozzle. So piping always runs from larger to smaller diameter. Elbow(s) or swivel adaptors used at the nozzle for aiming, DO NOT count toward the total elbows allowed per system or the number of elbows between two (2) nozzles. ULEX 6885 ULC-EX 6885 May 1, 2019 Chapter 3 - System Design Page 3 - 14 Revision 6 DETECTOR PLACEMENT Detectors (fusible links) are required to be Dlaced in the air stream of each appliance (one detector per appliance) and in the opening of the exhaust duct(s) of protected ventilation hoods. Detectors shall be located in the plenum area of the ventilation hood behird the filters, which provide protection for the detection system. Exhaust Duct Detector Placement Each exhaust duct must have at least one (1) detectcr installed. The detector is to be centered in the duct entrance and no more than 12" (30.5 cm) into ductwork. Cooking Appliance Detector Placement Each cooking appliance with a continuous cooking surface area of less than 48" (122 cm) x 48" (122 cm) must be protected by one (1) detector. The detector is to be located over the surface of the appliance and in its air stream when the ventilation system is turnedlon. Cooking appliances with continuous cooking surfaces larger than 48" (122 cm) x 48" (122 cm) must be protected by multiple detectors, using one detector for every 48" ( 22 cm) x 48" (122 cm) of continuous cooking area. Exception: If a cooking appliance or appliances are located under a duct opening where a detector has been mounted, it is not necessary to utilize an additional detector as long the duct detector is not more than 12" (30.5 cm) into the duct opening. See Figure 3-26. APPLIANCE APPLIANCE APPLIANCE APPLIANCE COVERED COVERED COVERED COVERED BY BY BY BY DETECTOR DETECTOR DETECTOR DETECTOR A B B C Figure 3-26. Proper Detector Placement Appliances and Duct ULEX 6885 ULC-EX 6885 BPN: BFR-TM May 1, 2019 Buckeye KITCHEN MISTER Coverage Summary Sheet This summary sheet is provided as a quick reference, a complete understanding of the technical manual (BFR-TM) is required. The most current Buckeye Kitchen Mister Restaurant Cooking Area Fire Suppression System Technical Manual (Part Number: BFR-TM) supersedes this reference sheet. It is essential that this reference sheet be compared with the current technical manual before using. Dimensions given in inches (cm) unless otherwise noted. DUCT, SMALL [50" (127) MAXIMUM PERIMETER] NOZZLE: N-1LP FLOW PTS.: 1 COLOR BAND: RED 0 DUCT 16"(41) MAX. NOZZLE TIP I - 1"(2.5).6"(15) NOZZLE TIP NOZZLEJ I_T W HOOD/PLENUM LONGEST SIDE 16-3/4" (43) PLENUM, SINGLE & 4 FT 1/3H "V" BANK IQduI_., NOZZLE FLOW PTS.: 1 COLOR BAND: BLUE '' V BANK (3.7M) MAX. __ ~-(5) ______ 11 2 FT. M) MAX. I 12 FT. H______ Vo SINGLE BANK DUCT, LARGE 050' (381) MAXIMUM PERIMETER] NOZZLE: N-2W FLOW PTS.: 2 COLOR BAND: WHITE 0'-6'(15) P DUCTS NOZZLE TI NOZZLE TIP NOZZLE W TIP LONGEST SIDE: 50" (127) HOOD/PLENUM This Section Intentionally Blank CAN BE USED WITH BACK-SHELF, SHELF MUST NOT INTEFERE WITH NOZZLE DISCHARGE MAX HEIGHT 40" (102> AIM: 6" (15) FROM MIN HEIGHT E EDGE, OPPOSIT ONLONG CENTER MAX. HAZARD MAX. HAZD BURNER PLACEMENT. 3' WIDTH: 24" (61) BURNER TO LENGTH: 12" (30.5) LENGTH: FROM FRONT OR BACK EDGE. ON LONG CENTER LINE 24-(61) RANGE, FOUR BURNER, (HIGH PROXIMITY) NOZZLE: N-1LP PLACEMENT: FLOW PTS.: 1 WIThIN 3" (7.6) COLOR BAND: OF CENTER RED AIM: CENTER OF RANGE BURNER WIDTH: 24"(61) RANGE, TWO BUR (LOW PROXIMITY) NOZZLE: N-1LP FLOW PTS.: 1 COLOR BAND: RED MAX. HEIGHT: 30" 176) MIN. HEIGHT: 16"(41) RANGE, SIX BURNER PLACEMENT: CENTER OF RANGE NOZZLE: N-2LP MAX HEIGHT: FLOW PTS.: 2 43"(109) COLOR BAND: —MIN. HEIGHT YELLOW CENTER 35 (89) OF RANGE BURNERTO BURNER 0 BURNERTO LENGTH: 36"(91) BURNER WIDTH: 24"(61) DEEP FAT FRYER, LG. SINGLE VAT NOZZLE: N-2HP PLACEMENT: FLOW PTS.: 2 WITHIN THE COLOR BAND: RIMETER OF GREEN H HAZARD MAX. HEIGHT:45"(114)— MIN. HEIGHT: 24"(61) AIM: CENTER '"' g(51) OF HAZARD AREA Note: Total hazard area can not IDTH: exceed 664 in2 MAX LEN 24" (6 1) (5,574 cm2). 20.25 BPN: P1S10374 RANGE/GRIDDLE COMBINATION NOZZLE: N-1LP FLOW PTS.: 1 COLOR BAND: MAX. HEIGHT: t PLACEMENT: RED 40"(102)WITHIN 3" (7.6) MIN. HEIGHT:OF CENTER 30(76)AIM: CENTER OF MAX.12" MAX. TILTING SKILLET HAZARD COVERAGE AREA: NOZZLE: N-2HP 20.25"(51)x24"(61) FLOW PTS.: 2 COLOR BAND: COVER MUST GREEN NOT INTEFERE FOR MIN. & MAX. DISCHARGE WITH NOZZLE NOZZLE HEIGHTS, POSITION AND AIM POINT REFER TO FRYER NOZZLE PARAMETERS SHELF WIDTH: NOT To RANGE, WITH BACKSH ELF, EXCEED 11- (28) (HIGH PROXIMITY) HEIGHT. NOZZLE: N-21-P 40"I1021___ FLOW PTS.: 2 E2CEr AREA COLOR BAND: MIN. HEIGHT: - YELLOW 30-(76) MINIMUM AIM: 6" 1151 SHELF HEIGHT FRO MBACK EDGE ON 16"I41I. CENTERLINE (1 ir 5) MAX. BURNER EDGE 9"(22.5) TO BURNER BURNER EDGE EDGE: 24" 1611 CAN BE TO BURNER USED EDGE:24" I8lI 6" WITHOUT A 1151 BACK-SHELF This Section Intentionally Blank REV. 5; DATE: JANUARY 1, 2013 LENGTH: 36'(91) Buckeye KITCHEN MISTER Coverage Summary Sheet This summary sheet is provided as a quick reference, a complete understanding of the technical manual (BFR-TM) is required. The most current Buckeye Kitchen Mister Restaurant Cooking Area Fire Suppression System Technical Manual (Part Number: BFR-TM) supersedes this reference sheet. It is essential that this reference sheet be compared with the current technical manual before using. Dimensions given in inches (cm) unless otherwise noted. GRIDDLE, STANDARD [42'(107) MAX.] NOZZLE: N-1 LP FLOW PTS.: 1 COLOR BAND: RED A.- PLACEMENT: ON THE PERIMETER OF THE HAZARD AIM:6" 1151 MAX. HEIGHT: FROM CENTER OF HAZARD -48'(122) AREA. INLINE -MIN. HEIGHT: WITH NOZZLE 24 (61) MAX. LENGTH: 42'(107) ""AX .WIDTH: MANIMUMOF GRIDDLE, LOW 3"(7.8) FROM EDGE PROXIMITY MAXIMUM ______________ HEIGHT: NOZZLE: N-2W 30• (78) FLOW PTS.:2 NOZZLE PLACEMENT MEA COL OR BAND: WHITE MINIMUM HEIGHT: 10 (25) 'I6o6 MAX 114 MAXIMUM LENGTH(L): "'%_. I ..-" 85" (152> 30" (76) RADIANT CHARBROUIR NOZZLE: N-1 HP PLACEMENT: WITHIN FLOW PTS.: 1 THE PERIMETER OF COLOR BAND: THE HAZARD BLUE MAX. HGHT -48-(122) AIM: CENTER OF HAZARD HEIGHT AREA 30-(76) GRIDDLE, LARGE [48" (122) MAX, NOZZLE: N-ILP FLOW PTS.: 1 PLACEMENT: 6" COLOR BAND: RED (15) OFF GRIDDLE EDGE, ON LONG CENTER LINE MAX. HEIGHT: 6M. 43'(1091.. STUIFROM ) CENTER. IN tiNE WITH NOZZ.E MIN. HEIGHT 30'(76). J65 ._ MAX. LENGTH: MAX. WIDTH: 48" (122) 30'(76) GRIDDLE, EXTRA LOW PROXIMITY MAXIMUM HEIGHT NOZZLE: N-2W 10'(25) FLOW PTS.:2 NOZZLE PLACEMENT SHALL BE ABOVE COLOR BAND: MINIMUM ANY CORNER WHITE HEIGHT L=W MAXIMUM MAXIMUM LENGTH(L): WIOTH(W(: 45" (107) 30" (76) LAVA ROCK CHARBROILER NOZZLE: N-211P FLOW PTS.: 2 COLOR BAND: PLACEMENT: WITHIN THE GREEN 024' ER OF THE HAZARD MAX. HEIGHT MIN. HEIGHT: AIM: CENTER OF HAZARD AREA MAX LEN (/ WIDTH: 24"(61) 24'(61 GRIDDLE, X-LARGE [60 (152) MAX.] NOZZLE: N-2LP PLACEMENT: ON ER COLOR BAND RD YELLOW MAX. FLOW PTS.: 2 024'(61) HEIGHT: AIM: 8"(20)48"(122) FROM CENTER INOF HAZARD AREA INLINE EIGHT: WITH NOZZLE MAX. LENGTH: 60'(152) (76) WOK NOZZLE: N-1HP AIM: TCEN EROF WOK EOTFOM HEIGHT: FLOW ""-'-________,______-----/' 48" (122) PTS.: 1 MIN. -HEIGHT COLOR 30'(76) BAND: BLUE PLACEMENT: HWITHIN THE MAX WOK DIA 30 MIN. WOK DLA.. 12 BROILER AND UPRIGHT BROILER NOZZLE: N-ILP FLOW PTS.: 1 AIM: CENTER I COLOR BAND: RED OF COOKING GRATE PLACEMENT: TOP I CORNER OF U FRONT OPENING MAX. LENGTH: 38(91) MAXIMUM PIPING PER CYLINDER SIZE Piping Limitations: >3/8" (17.1 mm OD) or 1/2"(21.3 mm OD) Minimum Piping Requirements (Wok, Range, & DFF only): CYLINDER MAX. FLOW MAX. PIPE VOLUME MAX. PIPE VOL.BETWEEN MAX. # OF Sch. 40 black pipe. > Min. # of elbows before Closest SIZE POINTS ALLOWED (mL) ANY TWO NOZZLES (mL) ELBOWS > Pipe sized largest to smallest only. > No 'traps allowed. > Max. number of elbows between any (2) nozzles: 5. nozzle: 5. > Mm. pipe volume before closest nozzle: 360 mL. BFR-5 5 1500 1000 20 BFR-10 10 2500 2000 25 > Max. vertical rise: 10 feet (3m). > Total system pipe volume: 600 mL BFR-1 5 15 2800 2500 25 > Max. vertical rise from nozzle to supply line: 2 feet (0.6 m). > Minimum number of flow points in system: 3. BFR-20 20 2800* 2500 25 * Total volume of 3/8" piping allowed is ZUU mL. CONDUIT AND BUCKEYE SHIELDED CABLE (BSC) LIMITATIONS I PIPE SIZE (SCH. 40) I PIPE VOLUME FUNCTION MAX. CONDUIT LENGTH FT (M) MAXIMUM NUMBER OF CORNER PULLEYS MAX. LENGTH OF BSC FT (M) MAXIMUM NUMBER OF BENDS IN THE BSC (MIN. BEND RADIUS) BSC TO CONDUIT TRANSITIONS (NUMBER OF BSCI) MAXIMUM NUMBER OF FUSIBLE LINKS AND HOLDERS 3/8 in. (17.1 mm OD) pipe 37.6 mL./ft. (123mL/m) 112 in. (21.3 mm OD) pipe I 59.8 mL./ft. (196mL/m) REMOTE CYLINDER ACTUATION LIMITATIONS ACTUATION CARTRIDGE PART NUM3ER NUMBER OF CYLINDER(S) THAT CAN BE MAX. LENGTH OF 1/4" (0.6) OD COPPER TUBING BETWEEN ACTUATED MAX. LENGTH OF TUBING CYLINDERS FUSIBLE LINK LINE; CONDUIT& BSC 25(7.6) 8 35(10.7) 6 [9' (23)] 1 6 10 GAS VALVE LINE; CONDUIT & BSC 25(7.6) 8 35 (10.7) 6 [9" (23)] 6 NA RPS-M LINE; CONDUIT&BSC 25(7.6) 8 35(10.7) 6[9" (23)] 6 NA FUSIBLE LINK LINE; CONDUIT ONLY 150(45.7) 35 NA NA NA 20 GAS VALVE LINE; CONDUIT ONLY 150 (45.7) 35 NA NA NA NA BFR-AC-S 1-3 15 FEET (4.6 m) 3 FEET (0.9 m) RPS-M LINE; CONDUIT ONLY 150(45.7)1 35 NA NA NA NA FUSIBLE LINK LINE; BSC ONLY NA NA 35(10.7) 6[9"(23)] 6 10 BFR-AC-L 1-5 25 FEET (7.6 m) 3 FEET (0.9 m) GAS VALVE LINE; BSC ONLY NA NA 35 (10.7) 1 6 [9" (23)] 6 NA RPS-M LINE; BSC ONLY NA NA 1 35 (10.7) 6 [9" (23)] 6 NA > BSC CAN NOT be coiled or looped when installed. BPN: PlS10374 REV. 5 DATE: JANUARY 1, 2013