Loading...
HomeMy WebLinkAbout2810 CARIBOU CT; 110; FPC2020-0151; Permitt(rcity of Carlsbad FiiiBnm1 Print Date: 12/03/2020 Permit No: FPC2020-0151 Job Address: 2810 CARIBOU CT, # 110, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091200300 Track #: Applied: 08/27/2020 Valuation: $251,758.63 Lot #: Issued: 09/22/2020 Occupancy Group: Project #: Finaled Close Out: 12/03/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: ZENSE -SPRINKLER TI (20 HEADS) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611S MELROSE PL, #244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Vertical Sidewall Bulletin 014 Rev. L Reliable Model Fl FR Series Quick Response Standard Spray CD C :3 0 - I Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Spunkier Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH 5 *NSF Certified to NSF/ANSi Standard 61 Annex G 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA 1425), 0786-CPD-40252 (RA 1475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR56, Fl FR56LL, I.i,IF,IIIEj Upright Pendent Horizontal Sidewall 4 Recessed Concealed Horizontal Sidewall Pendent XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Conventional TON Recessed Pendent/Fl/F2 Recessed PendentjFP Ir XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. */J tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL" K5.6 Quick 1/2" NFl See See F1FR42 **F1FR42LL0) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature Finish Table" F1FRXLH Ratings" Table. F1FR28 1 K2.8 "Low Lead Sprinklers available only with Temperature Rating 200°F/930C Material Data: Frame Deflector Load Screw *Plntle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA AlloySlo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor _______________ Sprinkler (SIN) __________ Approval __________ Sprinkler Identification Number Size US J Metric Height Organization I Upright J Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2' (15mm) (1) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1, 2, 3, 4, 6 RA1425(1)(2)(3))4) I 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA1423(1)(4) I RA1413 3/8(10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA142114> RA14114 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) F 5.6 I 80 2.25" (57mm) 1,5 RA1415 11 mm) 1/2" NPT (R1/2) [ 4.2 60 2.25" (57mm) 1,5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. 4. Vertical Sidewall *DuPont Registered Trademark Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Modal Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler0 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) I 1/2" NPT (R1/2) 1 4.2 60 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions L TI. REDUCE? 2 5/ OL4 (66.7mm) - HOLE IN CONING 2 5/I6 DIN (667mm) CUP FACE OF FITTING It) FACE OF CONING DIMADUSION AT MWMUM R - I-I/2Tmm] AT MINIMUM RECESS - IT2S4a,mJ AT MAXIMUM RECESS - 9/I6TI4.3,,,mJ AT MINIMUM RECESS - I25.4mn1) US ADJTTICE4 _____ 3 I/4 (82.6mm) 1 L-d-r-SS-S1 RUSS CRUAR MERE DUST AMIDST W*1UM MESS AWUSIMENT ES ADJUSTMENT - 7 /STREEEJECR FACE OF ATTIRE ra tact OF CEilING DIMENSION FT SCZITO*UV at WAIMUM RECESS - TT25.a.,mJ at MINIMUM RECESS / /fS CUTENFUS Vat LUXIMUM REcESS - AT DRECESS j~ ELII~ ESS 7/87222,,,,,,3 ESS I-S/Btill2nmj ESSI-I/812a6n,n,J SS - -5/B 7413mm) Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA1 485(2)(3) 15mm ½" NFl (R1/2) 5.6 80 2.25" (57mm) 3(1) "LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon Plated - cULus listed Corrosion Resistant