HomeMy WebLinkAbout2810 CARIBOU CT; 110; FPC2020-0151; Permitt(rcity of
Carlsbad
FiiiBnm1
Print Date: 12/03/2020 Permit No: FPC2020-0151
Job Address: 2810 CARIBOU CT, # 110, CARLSBAD, CA 92010 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2091200300 Track #: Applied: 08/27/2020
Valuation: $251,758.63 Lot #: Issued: 09/22/2020
Occupancy Group: Project #: Finaled Close Out: 12/03/2020
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check #: Final Inspection:
Project Title:
Description: ZENSE -SPRINKLER TI (20 HEADS)
Applicant: FPContractor:
TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC
JOHN CAPUTO 1611S MELROSE PL, #244
1611A S MELROSE DR VISTA, CA 92081-5471
VISTA, CA 92081-5407 (760) 525-4329
(760) 525-4329
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
Vertical Sidewall
Bulletin 014 Rev. L
Reliable Model Fl FR Series
Quick Response
Standard Spray
CD C
:3
0
-
I
Model Fl FR56 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
Model Fl FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP
Horizontal Sidewall
Model Fl FR56 Concealed Sprinkler Types
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler
Types
Standard Upright
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Recessed
Sprinkler Types
Standard Pendent
Model Fl FR56LL & Fl FR42LL Low Lead Spunkier
Types*
Standard Pendent
Less than 0.25% Lead Content
Listing & Approvals
Underwriters Laboratories Inc. and Certified for
Canada (cULus).
Factory Mutual Approvals (FM)
Loss Prevention Council (LPCB, UK)
VdS SchadenverhUtung GmbH
5 *NSF Certified to NSF/ANSi Standard 61 Annex G
6. EC Certificate: 0786-CPD-40239 (RA1414), 0786-
CPD-4025 1 (RA 1425), 0786-CPD-40252 (RA 1475)
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Quick Response Sprinkler
Product Description
Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & F1FR28 Series Sprinklers are quick response
sprinklers which combine the durability of a standard sprin-
kler with the attractive low profile of a decorative sprinkler.
The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & Fl FR28 Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers.
This quick response enables the Model Fl FR56, Fl FR56LL,
I.i,IF,IIIEj
Upright Pendent
Horizontal Sidewall
4
Recessed Concealed
Horizontal Sidewall Pendent
XLH Upright XLH Pendent
F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Series sprinklers to apply wa-
ter to a fire much faster than standard
sprinklers of the same temperature rat-
ing.
The glass bulb consists of an accu-
rately controlled amount of special fluid
hermetically sealed inside a precisely
manufactured glass capsule. This glass bulb is specially
constructed to provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid
expands, forcing the bubble smaller and smaller as the liq-
uid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.
Conventional
TON
Recessed
Pendent/Fl/F2
Recessed
PendentjFP
Ir
XLH Recessed
Pendent F1/F2
XLH Recessed
Pendent FP
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Application
Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick
response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
*/J tie
(XLH Only)
Deflector
Load Screw
Washer Bulb
Frame Cup
0 14FGO6A
Model F1FR42, F1FRXLH Upright
Technical data:
Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure
F1FR56
**F1 FR56LL" K5.6
Quick 1/2" NFl See See F1FR42
**F1FR42LL0) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature Finish Table"
F1FRXLH Ratings" Table.
F1FR28 1 K2.8
"Low Lead Sprinklers available only with Temperature Rating 200°F/930C
Material Data:
Frame Deflector Load Screw *Plntle Cup Washer Bulb
DZR Brass CDA Alloy 260,
CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360
QM Brass or or or coated with PTFE Adhesive Glass
**Low Lead Brass or
CDA AlloySlo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
2.
Model Fl FR56, Upright, Pendent & Conventional Sprinklers
Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
____________
Nominal K Factor
_______________
Sprinkler (SIN) __________
Approval
__________
Sprinkler Identification Number
Size US J Metric Height Organization I Upright J Pendent
Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position
1/2' (15mm) (1) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1, 2, 3, 4, 6 RA1425(1)(2)(3))4) I
7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA1423(1)(4) I RA1413
3/8(10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA142114> RA14114
Conventional-Install in Upright or Pendent Position
15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 RA14753
cULus listed corrosion resistant (Polyester coated) sprinkler.
Polyester coated FM approved sprinkler.
Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475.
Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant
Upright Pendent Conventional
Model Fl FR56LL & Fl FR42LL Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number
(SIN)
Size US Metric Height Organization Pendent
Standard-Pendent Deflectors Marked to Indicate Position
1/2" (15mm) (1) 1/2" NPT (R1/2) F 5.6 I 80 2.25" (57mm) 1,5 RA1415
11 mm) 1/2" NPT (R1/2) [ 4.2 60 2.25" (57mm) 1,5 RA1410
(1) cULus listed corrosion resistant (Polyester coated) sprinkler.
*DuPont Registered Trademark
3.
4.
Vertical Sidewall
*DuPont Registered Trademark
Sprinkler Type Deflector to Ceiling Distance
(Mm. - Max.)
Upright 4" (102mm) - 12" (305mm)
Pendent 4" (102mm) - 12" (305mm)
Modal Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler0
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414
7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413
3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1411
(1) Refer to escutcheon data table for approvals & dimensions
Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415
7/16" (10mm) I 1/2" NPT (R1/2) 1 4.2 60 2.25" (57mm) RA1410
(1) Refer to escutcheon data table for approvals & dimensions
L
TI.
REDUCE?
2 5/ OL4 (66.7mm) -
HOLE IN CONING
2 5/I6 DIN (667mm) CUP
FACE OF FITTING It) FACE OF CONING DIMADUSION
AT MWMUM R - I-I/2Tmm]
AT MINIMUM RECESS - IT2S4a,mJ
AT MAXIMUM RECESS - 9/I6TI4.3,,,mJ
AT MINIMUM RECESS - I25.4mn1) US ADJTTICE4 _____
3 I/4
(82.6mm) 1
L-d-r-SS-S1
RUSS CRUAR MERE DUST AMIDST W*1UM MESS
AWUSIMENT
ES
ADJUSTMENT
- 7 /STREEEJECR
FACE OF ATTIRE ra tact OF CEilING DIMENSION
FT SCZITO*UV at WAIMUM RECESS - TT25.a.,mJ at MINIMUM RECESS / /fS CUTENFUS
Vat LUXIMUM REcESS - AT DRECESS
j~
ELII~
ESS 7/87222,,,,,,3
ESS I-S/Btill2nmj
ESSI-I/812a6n,n,J SS - -5/B 7413mm)
Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28F1 or F2
Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28 FP
Model Fl FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal Nominal K Factor Sprinkler Approval Sprinkler
US Metric Orifice Thread Size Height Organizations Identification
Numbers (SIN)
½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA1 485(2)(3)
15mm ½" NFl (R1/2) 5.6 80 2.25" (57mm) 3(1)
"LPC Approval is for pendent position only.
cULus Listed corrosion resistant (Polyester coated) sprinkler.
Electroless Nickel PTFE (Teflon Plated - cULus listed Corrosion Resistant