HomeMy WebLinkAbout2736 ARLAND RD; ; FPR2020-0041; Permit[F1
City of
Carlsbad
Fniiaeimi1t
Print Date: 01/05/2021
Job Address: 2736 ARLAND RD, CARLSBAD, CA 92008
Permit Type: FIRE-Construction Residential Work Class:
Parcel #: 1561425600 Track #:
Valuation: $259,738.44 Lot #:
Occupancy Group: Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #:
Plan Check #:
Permit No: FPR2020-0041
Status: Closed - Finaled
Single Family Fire Sprinkl
Applied: 05/28/2020
Issued: 06/16/2020
DEV2019-0137 Finaled Close Out: 01/05/2021
Inspector:
Final Inspection:
Project Title: LIN RESIDENCE
Description: LIN RESIDENCE -NEW 13D SPRINKLER SYSTEM FOR SFR (24 HEADS)
Applicant: FPContractor:
SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC
ANGELA ZUMAYA 12155 PAINE PL
12155 PAINE PL P0 WAY, CA 92064-7154
POWAY, CA 92064-7154 (619) 588-6364
(619) 588-6364
FEE AMOUNT
FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00
FIRE NFPA 13D Single Family System (Plan Review) $246.00
Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov
ffc2o2-o -•
I
alaFA TL& VrWW
ISPFSlSI1E • •
12 155 PANE PLACE
P0 WAY, CA 92064
HYDRAULIC CALCULATIONS
FOR
L1N RESIDENCE
FILE NUMBER: 20-0374.SDF
DATE: MAY 21, 2020
-DESIGN DATA-
OCCUPANCY CLASSIFICATION: RESIDENTIAL
DENSITY: .05 gpm! 512 sq.ft.
AREA OF APLICATION: 2nd FLOOR
COVERAGE PER SPRINKLER: 256 sq.ft.
NUMBER OF SPRINKLERS: 2 SPRINKLERS
TOTAL SPRINKLER WATER FLOW REQUIRED: 26.4 gpm
TOTAL WATER REQUIRED (including hose): 31.4 gpm
FLOW AND PRESSURE (@ BOR): 26.4 gpm @ 33.1 psi
SPRINKLER ORIFICE SIZE: 1/2" inch
NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC.
DESIGN! LAYOUT: FRANCISCO IBARRA
AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT
CONTRACTOR CERTIFICATION NUMBER: C16-682025
WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT
CONTACT: CHRIS (760) 602-2750
WATER PRESSURE INFORMATION: 66 psi STATIC
CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930)
HRS SYSTEMS, INC.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf
JOB DITLE: LIN RESIDENCE TWO HEAD CALC
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 59.4 58.0 500.0 59.4 31.4 57.1
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 31.4 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.4 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM)
1 8.0 SOURCE 57.1 31.4
2 10.0 - - - - 50.1 - - -
3 10.0 - - - - 46.1 - - -
3A 0.0 - - - - 40.1 - - -
4 0.0 - - - - 37.9 - - -
5 2.0 HOSE STREAM 33.1 5.0
6 10.5 - - - - 19.5 - - -
7 10.5 - - - - 17.4 - - -
8 23.0 - - - - 12.0 - - -
8A 22.5 - - - - 12.2 - - -
9 25.5 - - - - 7.1 - - -
9A 22.5 K= 4.90 7.0 13.0
10A 23.5 K= 4.90 7.5 13.4
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf
JOB ITLE: LIN RESIDENCE TWO HEAD CALC
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 31.4 0.995 PL 15.00 PF 6.2
1 8.0 SRCE 57.1 (N/A) 13.0 150 FTG TG PE -0.9
2 10.0 0.0 50.1 0.0 0.257 TL 24.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 10.0 0.0 50.1 0.0 4.0 psi, 31.4 gpm
3 10.0 0.0 46.1 0.0
Pipe: 3 31.4 1.360 PL 165.00 PF 10.2
3 10.0 0.0 46.1 0.0 6.9 150 FTG 9L PE 4.3
3A 0.0 0.0 40.1 0.0 0.056 TL 183.00 PV
Pipe: 4 31.4 1.025 PL 5.00 PF 2.2
3A 0.0 0.0 40.1 0.0 12.2 150 FTG EL PE 0.0
4 0.0 0.0 37.9 0.0 0.222 TL 10.00 PV
Pipe: 5 31.4 1.101 PL 9.00 PF 3.9
4 0.0 0.0 37.9 0.0 10.6 150 FTG ET3RC PE -0.9
5 2.0 H.S. 33.1 5.0 0.157 TL 25.00 PV
Pipe: 6 26.4 1.101 PL 45.50 PF 9.9
5 2.0 H.S. 33.1 5.0 8.9 150 FTG 3E4TR PE -3.7
6 10.5 0.0 19.5 0.0 0.114 TL 87.50 PV
Pipe: 7 26.4 1.101 PL 10.00 PF 2.2
6 10.5 0.0 19.5 0.0 8.9 150 FTG E2R PE 0.0
7 10.5 0.0 17.4 0.0 0.114 TL 19.00 PV
Pipe: 8 0.0 1.101 PL 24.50 PF 0.0
7 10.5 0.0 17.4 0.0 0.0 150 FTG 2ET3R PE -5.4
8 23.0 0.0 12.0 0.0 0.000 TL 46.50 PV
Pipe: 9 0.0 1.101 PL 0.50 PF 0.0
8 23.0 0.0 12.0 0.0 0.0 150 FTG TR PE 0.2
8A 22.5 0.0 12.2 0.0 0.000 TL 6.50 PV
Pipe: 10 26.4 1.101 PL 16.50 PF 3.8
7 10.5 0.0 17.4 0.0 8.9 150 FTG 2E3R FE -6.5
9 25.5 0.0 7.1 0.0 0.114 TL 33.50 PV
Pipe: 11 13.0 1.101 PL 9.50 PF 1.3
9 25.5 0.0 7.1 0.0 4.4 150 FTG 4ETR PE 1.3
9A 22.5 4.9 7.0 13.0 0.031 TL 43.50 PV
Pipe: 12 13.4 1.101 PL 2.00 PF 0.5
9 25.5 0.0 7.1 0.0 4.5 150 FTG ETR PE 0.9
10A 23.5 4.9 7.5 13.4 0.032 TL 15.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf
JOB 1'ITLE: LIN RESIDENCE TWO HEAD CALC
NOTES (HASS)
Calculations were performed by the HASS 8.8 D computer program
in accordance with NFPA13 (2016)
under license no. 38071930 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.010 gpm and a maximum
imbalance at any node of 0.122 gpm.
Total pressure at each node is used in balancing the system.
Maximum water velocity is 13.0 ft/sec at pipe 1.
Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
Available pressure at source node 1 under full flow conditions is
59.39 psi with a flow of 32.13 gpm.
PIPE FITTINGS TABLE
User Pipe Table Name: FSS.PIP
PAGE: H MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T R K C L B L
Ell Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 5/21/2020 C:\program fiies\HRS Systems\hass87\HASS DATA\20-0374.sdf
'JOE TITLE: LIN RESIDENCE TWO HEAD CALC
PAGE: K MATERIAL: CPPR-K HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf
JOB TITLE: LIN RESIDENCE TWO HEAD CALC
WATER SUPPLY ANALYSIS
Static: 59.40 psi Resid: 58.00 psi Flow: 500.0 gpm
70.0
60.0
G 1
A 2
U
50.0
G
E
40.0 P
R
E
S 30.0
S
U
R 20.0
E
10.0
p
S
0.0
-14.7
LEGEND
Available pressure
59.39 psi @ 31.4 gpm
Required pressure
57.08 psi @ 31.4 gpm
Source Supply Curve
System Demand Curve
100150 200 250 300 350 400 450 500
FLOW (GPM)
)te: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf
JOB TITLE: LIN RESIDENCE TWO HEAD CALC
WATER SUPPLY CURVE
600\\\\\\\\
I \\\\\\\\\
x * <-58.0 psi @ 500 gpm
Flow Test Point
55+
50+
45+
P 40+
R I
E I
S I
S 35+
U I
R I
E
30+
P I
S I
I 25+
) I
20+
15+
10+ LEGEND
I 'V
I X = Required Water Supply
I 57.08 psi 8 31.4 gpm
5+ It
0 = Available Water Supply
59.39 psi 8 31.4 gpm
It
0++-+---+----+-----+------+--------+--------+---------+-----------+
200 300 400 500 600 700 800 900 1000
FLOW (GPM)
ff 7A !FW
RESPNISIE • •
12 155 PAINE PLACE
P0 WAY, CA 92064
HYDRAULIC CALCULATIONS
FOR
LIN RESIDENCE
FILE NUMBER: 20-0374.SDF
DATE: MAY 21, 2020
-DESIGN DATA-
OCCUPANCY CLASSIFICATION:
DENSITY:
AREA OF APLICATION:
COVERAGE PER SPRINKLER:
NUMBER OF SPRINKLERS:
TOTAL SPRINKLER WATER FLOW REQUIRED:
TOTAL WATER REQUIRED (including hose):
FLOW AND PRESSURE (@ BOR):
SPRINKLER ORIFICE SIZE:
RESIDENTIAL
.05 gpm/ 400 sq.ft.
M. BATHROOM
400 sq.ft.
1 SPRINKLER
21.0 gpm
26.0 gpm
21.0 gpm @39.1 psi
l!2" inch
NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC.
DESIGN! LAYOUT: FRANCISCO IBARRA
AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT
CONTRACTOR CERTIFICATION NUMBER: C16-682025
WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT
CONTACT: CHRIS (760) 602-2750
WATER PRESSURE INFORMATION: 66 psi STATIC
CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930)
HRS SYSTEMS, INC.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF
JOB TITLE: LIN RESIDENCE ONE HEAD CALC
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 59.4 58.0 500.0 59.4 26.0 56.4
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 26.0 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM)
1 8.0 SOURCE 56.4 26.0
2 10.0 - - - - 51.2 - - -
3 10.0 - - - - 47.2 - - -
3A 0.0 - - - - 44.3 - - -
4 0.0 - - - - 42.8 - - -
5 2.0 HOSE STREAM 39.1 5.0
6 10.5 - - - - 28.9 - - -
7 10.5 - - - - 27.5
8 23.0 - - - - 18.6 - - -
8A 22.5 K= 4.90 18.4 21.0
9 25.5 - - - - 21.0 - - -
9A 22.5 - - - - 22.3 - - -
10A 23.5 - - - - 21.9 - - -
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF
JOB TITLE: LIN RESIDENCE ONE HEAD CALC
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 26.0 0.995 PL 15.00 PF 4.3
1 8.0 SRCE 56.4 (N/A) 10.7 150 FTG TG PE -0.9
2 10.0 0.0 51.2 0.0 0.181 TL 24.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 10.0 0.0 51.2 0.0 4.0 psi, 26.0 gpm
3 10.0 0.0 47.2 0.0
Pipe: 3 26.0 1.360 PL 165.00 PF 7.2
3 10.0 0.0 47.2 0.0 5.7 150 FTG 9L PE 4.3
3A 0.0 0.0 44.3 0.0 0.040 TL 183.00 PV
Pipe: 4 26.0 1.025 PL 5.00 PF 1.6
3A 0.0 0.0 44.3 0.0 10.1 150 FTG EL PE 0.0
4 0.0 0.0 42.8 0.0 0.157 TL 10.00 PV
Pipe: 5 26.0 1.101 PL 9.00 PF 2.8
4 0.0 0.0 42.8 0.0 8.8 150 FTG ET3RC PE -0.9
5 2.0 H.S. 39.1 5.0 0.111 TL 25.00 PV
Pipe: 6 21.0 1.101 PL 45.50 PF 6.5
5 2.0 H.S. 39.1 5.0 7.1 150 FTG 3E4TR PE -3.7
6 10.5 0.0 28.9 0.0 0.074 TL 87.50 PV
Pipe: 7 21.0 1.101 PL 10.00 PF 1.4
6 10.5 0.0 28.9 0.0 7.1 150 FTG E2R PE 0.0
7 10.5 0.0 27.5 0.0 0.074 TL 19.00 PV
Pipe: 8 21.0 1.101 PL 24.50 PF 3.5
7 10.5 0.0 27.5 0.0 7.1 150 FTG 2ET3R PE -5.4
8 23.0 0.0 18.6 0.0 0.074 TL 46.50 PV
Pipe: 9 21.0 1.101 PL 0.50 PF 0.5
8 23.0 0.0 18.6 0.0 7.1 150 FTG TR PE 0.2
8A 22.5 4.9 18.4 21.0 0.074 TL 6.50 PV
Pipe: 10 0.0 1.101 PL 16.50 PF 0.0
7 10.5 0.0 27.5 0.0 0.0 150 FTG 2E3R PE -6.5
9 25.5 0.0 21.0 0.0 0.000 TL 33.50 PV
Pipe: 11 0.0 1.101 PL 9.50 PF 0.0
9 25.5 0.0 21.0 0.0 0.0 150 FTG 4ETR PE 1.3
9A 22.5 0.0 22.3 0.0 0.000 TL 43.50 PV
Pipe: 12 0.0 1.101 PL 2.00 PF 0.0
9 25.5 0.0 21.0 0.0 0.0 150 FTG ETR PE 0.9
10A 23.5 0.0 21.9 0.0 0.000 TL 15.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF
JOB TITLE: LIN RESIDENCE ONE HEAD CALC
NOTES (HASS)
Calculations were performed by the HASS 8.8 D computer program
in accordance with NFPA13 (2016)
under license no. 38071930 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.005 gpm and a maximum
imbalance at any node of 0.065 gpm.
Total pressure at each node is used in balancing the system.
Maximum water velocity is 10.7 ft/sec at pipe 1.
Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
Available pressure at source node 1 under full flow conditions is
59.39 psi with a flow of 26.74 gpm.
PIPE FITTINGS TABLE
User Pipe Table Name: FSS.PIP
PAGE: H MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T R K C L B L
Ell Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF
JOB TITLE: LIN RESIDENCE ONE HEAD CALC
PAGE: K MATERIAL: CPPR-K HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF
JOB TITLE: LIN RESIDENCE ONE HEAD CALC
WATER SUPPLY ANALYSIS
Static: 59.40 psi Resid: 58.00 psi Flow: 500.0 gpm
70.0 LEGEND
Available pressure
60.0
G 1
A 2
U
50.0
G
E
40.0 P
R
E
30.0
S
U
R 20.0
E
59.39 psi @ 26.0 gpm
Required pressure
56.43 psi @ 26.0 gpm
Source Supply Curve
System Demand Curve
10.0
p
S
i 0.0
-14.7
100150 200 250 300 350 400 450 500
FLOW (GPM)
)te: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 5/21/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF
JOB TITLE: LIN RESIDENCE ONE HEAD CALC
WATER SUPPLY CURVE
600\\\\\\\\
I \\\\\\\\\
I * <-58.0 psi @ 500 gpm
X Flow Test Point
55+
50+
45+
P 40+
R I
E I
S I
5 35+
U I
R I
E I
30+
P I
S I
I 25+
20+
15+
10+ LEGEND
I 'I
I X = Required Water Supply
56.43 psi @ 26.0 gpm
5+
I 0 = Available Water Supply
59.39 psi @ 26.0 gpm
0++-+---+----+-----+------+--------+--------+---------+-----------+
200 300 400 500 600 700 800 900 1000
FLOW (GPM)
Model RFC43 & RFC43LL Model RFC30 & RFC30LL
Model RFC49 & RFC49LL Model RFC58
Bulletin 006 January 2020
Model RFC Series Residential Sprinklers
Flat Concealed Pendent
cULus Listed
Features
cULus Listed as Residential Sprinklers
Push-On cover plate installation
Low water flow requirements
Product Description
Model RFC Series residential sprinklers are flat cover plate,
concealed pendent sprinklers intended for installation in
accordance with NFPA 13, NFPA 13R, or NFPA 13D. The
sprinklers are cULus Listed as Residential Sprinklers in ac-
cordance with UL 1626. In addition, Model RFCLL Series
sprinklers are cULus Certified for Health Effects to NSF/ANSI
standard 61 Annex G (LL) and Australian WaterMark Certified
(WMCS).
Model RFC30 sprinklers have a 165°F (74°C) temperature
rated fusible-link operating element. Model RFC43, RFC49,
RFC58, and RFC76 sprinklers are offered with either a 165°F
(74°C) or 212°F (100°C) temperature rated fusible-link oper-
ating element. Sprinklers with a 165°F (74°C) temperature
rating are ordinary temperature classification and are listed
for use with a 135°F (57°C) temperature rated cover plate.
Sprinklers with a 212°F (100°C) temperature rating are inter-
mediate temperature classificationand are listed for use with
a 165°F (74°C) temperature rated cover plate.
Model RFC Series sprinklers are installed with a Model RFC
or Model CS Cover Plate. Model G5 Cover Plates may be
installed by either pushing or threading the cover plate into
the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL,
RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover
plate adjustment. Model RFC58 and RFC76 sprinklers allow
3/4" (19 mm) of cover plate adjustment. Model RFC and G5
Cover Plates are available in a variety of finishes as listed in
Table H.
c/I
Model RFC76 Model RFC & G5 Cover Plate
Sprinkler Model Nominal K-Factor
gpm/p5i112 (I/mm/bar112)
Max. Coverage Area
ft x ft (m x m)
Listings &
Approvals
Sprinkler Identification
Number (SIN)
RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611
RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211
RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612
RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212
RFC49 4.9(71) 20x20(6.1 x6.1) cULus RA0616
RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216
RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613
RFC76 7.6(109) 20x20(6.1 x6.1) cULus RA0618
cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service.
LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content).
WMCS: Australian WaterMark Certified.
www.reliablesprinkler.com
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2" NPT or ISO 7-1 R1 /2
Nominal K-Factor: 3.0 (43 metric)
Max. Working Pressure: 175 psi (12 bar)
Mm. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Rating
165°F (74°C) sprinkler
135°F (57°C) cover plate
Cover Plate
Model RFC Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed to UL 1626
cULus Certified for Health Effects to NSF/ANSI
Standard 61 Annex G (RFC30LL only)
Watermark Certified (RFC30LL only)
Bottom View
Model RFC30 & RFC30LL Sprinkler Components and Dimensions
I 2-5/16° (58 mm)
Threads
Body
Cup
Tower 1-3/4° (44 mm) +1- 1/4(6 mm) _ Ii Fusible Link Nominal face of fitting to ceiling
Deflector (retracted) 3/16(5 mm)
I II Pin (extended)
I I
Deflector (extended)
Model G4/G5 Cover Plate 3-5/16 (84 mm) Dia. Ceiling
Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure (1)
7
Max. Coverage Area (2) Flow Pressure
ft. x ft. gpm psi
(m x m) (I/mm) (bar)
12x12 9 9.0
(3.6 x 3.6) (34) (0.62)
14x14 10 11.0
(4.3 x 4.3) (38) (0.76)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 006 Page 2 of 8
January 2020 MINNNORM www.reliablesprinkler.com
Bottom View
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2" NPT or ISO 7-1 R1/2
Nominal K-Factor: 4.3 (62 metric)
Max. Working Pressure: 175 psi (12 bar)
Mm. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI
Standard 61 Annex G (RFC43LL only)
Watermark Certified (RFC43LL only)
Sensitivity
Fast-response
Temperature Rating
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (1 00°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model RFC Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Model RFC43 & RFC43LL Sprinkler Components and Dimensions
I 2-5/16' (58 mm)
Threads Dia.
Body
Cup
Tower
.7
1-3/4" (44 mm) ~1- 1/4° (6 mm)
Nominal face of fitting to ceiling Fusible Link
Deflector (retracted)3 /16°(5 mm)
____________ •f \\\'''\ ____________
.-J I II Pin (extended)
Deflector (extended) --u'
Model G4/G5 Cover Plate 3-5/16° (84 mm) Dia. Ceiling
Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure111
Max. Coverage Area (2) Ordinary Temperature
___________________ Intermediate Temperature
Flow Pressure Flow Pressure ft. x ft
(m x m) gpm psi gpm psi
(I/mm) (bar) (I/mm) (bar)
15x15 12 7.8 12 7.8
(4.6 x 4.6) (45) (0.54) (45) (0.54)
16x16 13 9.1 13 9.1
(4.9 x 4.9) (49) (0.63) (49) (0.63)
18x18 18 17.5
(5.5x5.5) (68) (1.21) -- --
20x20 21 23.8
(6,1x6.1) (79) (1.64) -- --
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 006 Page 3 of 8
January 2020 www.reliablesprinkler.com
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2" NPT or ISO 7-1R1/2
Nominal K-Factor: 4.9 (71 metric)
Max. Working Pressure: 175 psi (12 bar)
Mm. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy Cover Plate
Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plate
Load Screw: Bronze Alloy
Towers: Copper Alloy Sprinkler Wrench
Pins: Stainless Steel Model FC (without wrench-able cap)
Deflector: Bronze Alloy Model W3 (with wrench-able cap) Bottom View Cup: Steel
Cover Plate Finishes Listings and Approvals
cULus Listed to UL 1626
(See Table H) cULus Certified for Health Effects to NSF/ANSI
Standard 61 Annex G (RFC49LL only)
Watermark Certified (RFC49LL onlv)
Model RFC49 & RFC49LL Sprinkler Components and Dimensions _J.LuI
Threads F- 2-5/16(58 mm)
Dia.
Body
_________________________
Cup
Tower 1-3/4"(44 mm) +1- 1/4° (6 mm)
Deflector (retracted) retr
Fusible Link Nominal face of fitting to ceiling
_ -ju- _________
3/16"(5 mm)
Pin (extended)
Deflector (extended)
AT—Ceiling Model G4/G5 Cover Plate 3-5/16' (84
Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure (1) 77
Max. Coverage Area (2) Ordinary Temperature
__________________
Intermediate Temperature
Flow Pressure Flow Pressure ft. x ft.
(m x m) gpm psi gpm psi
(I/mm) (bar) (I/mm) (bar)
16x16 13 7.0 13 7.0
(4.9 x 4.9) (49.0) (0.48) (49.0) (0.48)
18x18 17 12.0 17 12.0
(5.5 x 5.5) (64.3) (0.83) (64.3) (0.83)
20x20 20 16.7 21 18.4
(6.1 x6.1) (75.7) (1.15) (79.5) (1.27)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 006 Page 4 of 8
January 2020 www.reliablesprinkler.com
Sensitivity
Fast-response
Temperature Rating
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (1 00°C) sprinkler.
165°F (74°C) cover plate
Technical Specifications
Style: Flat Concealed Pendent
Threads: 1/2" NPT or ISO 7-1 R1/2
Nominal K-Factor: 5.8 (84 metric)
Max. Working Pressure: 175 psi (12 bar)
Mm. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor: Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Chrome Plated Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Ratings
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (1 00°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed
Bottom View
Model RFC58 Sprinkler Components and Dimensions
Threads —
Body
Cup
Tower -...
Fusible Link —
Deflector (retracted)
Pin (extended)
Deflector (extended) -
1-7/8° (48 mm) +1- 3/8(9 mm)
Nominal face of fitting to ceiling
L...... 2-5/16(58 mm)
Dia.
,,,,,,,_•[
3/16(5mm)
Model G4/G5 Cover Plate 3-5/16° (84 mm) Dia. Ceiling
Model RFC58 Sprinkler Hydraulic Design Criteria rnri
Minimum Flow and Residual Pressure 1)
Max. Coverage Area (2) Flow Pressure
ft. x ft. gpm psi
(m x m) (I/mm) (bar)
16x16 16 7.6
(4.9 x 4.9) (60.6) (0.53)
18x18 18 9.6
(5.5x5.5) (68.1) (0.66)
20x20 20 11.9
(6.1 x 6.1) (75.7) (0.82)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 006 Page 5 of 8
January 2020 NO A www.reliablesprinkler.com
Technical Specifications
Style: Flat Concealed Pendent
Threads: 3/4" NPT or ISO 7-1 R3/4
Nominal K-Factor: 7.6 (109 metric)
Max. Working Pressure: 175 psi (12 bar)
Mm. Spacing: 8 ft. (2.4 m)
Material Specifications
Thermal Sensor Nickel Alloy Solder Link
Sprinkler Body: Brass Alloy
Levers: Bronze Alloy
Yoke: Brass Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Towers: Copper Alloy
Pins: Stainless Steel
Deflector: Bronze Alloy
Cup: Steel
Cover Plate Finishes
(See Table H)
Sensitivity
Fast-response
Temperature Ratings
Ordinary:
165°F (74°C) sprinkler
135°F (57°C) cover plate
Intermediate:
212°F (100°C) sprinkler
165°F (74°C) cover plate
Cover Plate
Model G5 Cover Plate
Sprinkler Wrench
Model FC (without wrench-able cap)
Model W3 (with wrench-able cap)
Listings and Approvals
cULus Listed
Bottom View
Model RFC76 Sprinkler Components and Dimensions
2-5/16"(58 mm)
Threads —
Body
Cup
Tower -.
Fusible Link —
Deflector (retracted)
Pin (extended)
Deflector (extended) —
Dia.
1-7/8' (48 mm) +/- 3/8° (9 mm)
Nominal face of fitting to ceiling
r-31 °(5 ')
Model G4/G5 Cover Plate -' I- 3-5/16" (84 mm) Dia. Ceiling
Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure 1
Max. Coverage Area (2) Flow Pressure
ft. x ft. gpm psi
(m x m) (I/mm) (bar)
16x16 21 7.6
(4.9 x 4.9) (79.5) (0.52)
18x18 24 9.9
(5.5 x 5.5) (90.8) (0.68)
20x20 34 20
(6.1 x6.1) (128.7) (1.4)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2)the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 006 Page 6 of 8
January 2020 www.reIiablesprinkler.com
Cover Plate Finishes(')
Standard Finishes Special Application Finishes
White Polyester Off White Paint Black Paint Raw Brass
Chrome Plated Bright Brass Finished Bronze Black Plated
Satin Chrome Stainless Steel Clad(') Custom Color Paint(2)
Notes:
Paint or any other coating applied over the factory finish will void all approvals and warranties.
Custom color paint is semi-gloss, unless specified otherwise.
Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates
are not listed or approved as corrosion resistant.
Installation Dimensions
Recommended Mm. to Mm. to Max.
Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate
Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature
Model inch (mm) inch (mm) inch (mm) Ceiling1 Ceiling Rating
inch (mm) inch (mm)
RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F
RFC30LL G5 (84) (67) (13) (38t051) (13t025) (57°C)
RFC43, 135°F2
RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C)
RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 165°F3
RFC49LL (74°C)
135°F2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C)
RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 165°F3
(74°C)
Notes:
Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method
prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing
sprinklers.
For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (381C).
For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C).
Installation
Model RFC series sprinklers are intended to be installed in
accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as
the requirements of applicable authorities having jurisdiction.
Model RFC series sprinklers must not be installed in ceilings with
positive pressure in the space above. Ensure that the 4 slots in
the cup are open and unobstructed following installation. Model
RFC series sprinklers are shipped with a wrench-able protective
cap that should remain on the sprinkler until the sprinkler system
is placed in service following construction.
Model RFC series sprinklers can be installed without removing
the wrench-able protective cap using the Model W3 wrench.
Alternatively, Model RFC series sprinklers can be installed using
the Model FC wrench by temporarily removing the protective cap
during installation of the sprinkler. The use of any other wrench to
installed Model RFC series sprinklers is not permitted and may
damage the sprinkler. Fully insert the Model W3 wrench over
the cap until it reaches the bottom of the cup, or the Model FC
wrench over the sprinkler until the wrench engages the body.
Do not wrench any other part of the sprinkler/cup assembly. The
Model W3 and FC wrenches are designed to be turned with a
standard 1/2" square drive. Tighten the sprinkler into the fitting
after applying a PTFE based thread sealant to the sprinkler's
threads. Recommended installation torque is 8 to 18 ft-lbs (11
to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27
N-m) for 3/4" thread sprinklers.
Bulletin 006
January 2020
Do not exceed the maximum recommended torque. Exceeding
the maximum recommended torque may cause leakage or
impairment of the sprinkler. Use care when inserting or removing
the wrench from the sprinkler to avoid damage to the sprinkler.
Install the cover plate by hand by pushing the cover plate into the
cup and turning the cover in the clockwise direction until it is tight
against the ceiling.
Application
Model RFC series sprinklers are intended for installation where
residential sprinklers are permitted or required by NFPA 13,
NFPA 13R, and NFPA 13D. The sprinklers are concealed
pendent residential sprinklers.
Model RFC 30 and RFC30LL sprinklers are available in
ordinary temperature classification for installation where
the Maximum Ceiling Temperature does not exceed 100°F
(380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58,
and RFC76 sprinklers are available in either ordinary or
intermediate temperature classification for installation where
the Maximum Ceiling Temperature does not exceed 100°F
(38°C) or 150°F (660C), respectively.
Page 7 of 8
www.reliablesprinkler.com
Model FC
For use with Model RFC Series sprinklers
without wrench-able cap installed
Model W3
For use with Model RFC Series sprinklers
with wrench-able cap installed
Maintenance Guarantee
Model RFC series sprinklers should be inspected and the
sprinkler system maintained in accordance with NFPA 25. Do
not clean sprinklers with soap and water, ammonia or any other
cleaning fluids. Remove dust by gentle vacuuming. Replace
any sprinkler cover plate assembly which has been painted
(other than factory applied) or damaged in any way. A stock of
spare sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
sprinklers that would cause improper operation or non-oper-
ation.
Listings and Approvals
Listed by Underwriters Laboratories, Inc. and UL Certified for
Canada to UL1626, Residential Sprinklers for Fire-protection
Service (cULus).
Certified by Underwriters Laboratories, Inc. and Underwrit-
ers Laboratories of Canada for Health Effects to NSF/ANSI
Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL
only).
Australian WaterMark Certified (RFC30LL, RFC43LL, and
RFC49LL only).
For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms,
and conditions, visit www.reliablesprinkler.com.
Patents
Model RFC3O, RFC3OLL, RFC43, RFC43LL, RFC49, RFC49LL,
RFC58, and RFC76 sprinklers are covered by U.S. Patent No.
9,248,327 and U.S. Patent No. 7,275,603.
Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are
additionally covered by U.S. Patent No. 8,776,903.
Ordering Information
Specify the following when ordering.
Sprinkler
Model (RFC30, RFC30LL, RFC43, RFC43LL,
RFC49, RFC49LL, RFC58, RFC76)
Temperature Rating
Cover Plate
Model RFC or G5
Temperature Rating
Finish (See Table H)
Sprinkler Wrench
Model FC
Model W3
Bulletin 006 Page 8 of 8
January 2020 www.reIiablesprinkler.com
Bulletin 135 October 2019
Model Fl Res Series Glass Bulb
Residential Sprinklers
cULus Listed
Features
cULus Listed Residential Sprinklers
Available in pendent and horizontal sidewall orientations
Decorative finishes available, including recessed escutch-
eons and conical concealed cover plates
Product Description
Model FiRes Series sprinklers are residential sprinklers with a
3 mm glass bulb operating element. A variety of K-Factors as
well as recessed and conical concealed options are available
as detailed in this Bulletin.
The FiRes Series sprinklers are specially engineered for fast
thermal response to meet the requirements of UL 1626. They
are intended for installation in accordance with NFPA 13, 13R,
and 13D.
Application
The Model FiRes Series sprinklers cULus Listed Residential
sprinklers are intended for use in accordance with NFPA 13,
NFPA 13R, or NFPA 13D, The Model FiRes residential sprin-
klers are cULus Listed for use in residential occupancies and
residential portions of any occupancy, where permitted by
NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA
13D applications, the design flow and pressure shall not be
less than the minimum flow and pressure specified in the Listed
L
Design Criteria tables in this Bulletin. For NFPA 13 applications,
the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/
mm), but in no case shall the flow and pressure be less than
the minimum flow and pressure specified in the Listed Design
Criteria tables in this bulletin. Model Fl Res Series sprinklers are
listed for use in wet systems only.
Residential Sprinkler Summary ___________
Sprinkler Sprinkler
Identification Orientation
K-Factor
gpm/psP12 Thread Size Installation Options Max. Coverage Area
Model Number (SIN) (lpm/bar119 NPTorlSO7-1 ftxft(mxm)
F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x 16 (4.9 x 4.9)
F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20x20(6.1 x6.1)
F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1)
F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20x20(6.1 x6.1)
F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or 14 x 14(4.3 x 4.3)Recessed
F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed
F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed
F1Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed or 20x20(6.1 x6.1) Recessed
F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1)
F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1)
F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1)
F1 Res 58
HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9)
www.reliablesprinkler.com
2-1/4" (57mm)
DIA.
1-15/16"
(49mm) DIA.
Face of fitting
to finished
ceiling
1/2'(l3mm)
+1- 1/4" (6mm)
Technical Specifications Finishes
Style: Pendent and Recessed Pendent (See Table N)
Threads: 1/2' NPTor lS07-1R1/2
Nominal K-Factor: 3.0 (43 metric) Temperature Ratings
Max. Working Pressure: 175 psi (12 bar) 155°F(68°C)
175°F (79°C)
Material Specifications /
Thermal Sensor: 3 mm glass bulb Recessed Escutcheons
Sprinkler Frame: Brass Alloy F2 Recessed
Button: Copper Alloy RI Recessed*
Sealing Assembly: Nickel Alloy with PTFE °"
Load Screw: Bronze Alloy Sprinkler Wrenches
Deflector: Bronze Alloy Model W2
Model GFR2_(Recessed)
* Model FV escutcheons are not for use in positively pressurized ceiling plenums.
Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions
Threads
Wrench Flat
Dom Sealing Assembly 2-1/4" (liZ...TTJ')
Glass Bulb (57mm\
Load Screw
Deflector
T], 1/4"
(32mm)
Components Dimensions
1-3/4" (44mm) +1-
1/4(6mm)
2-7/8" (72mm) DIA.
F2 & FV Recessed Escutcheon Installation
Model F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems"
Maximum
Coverage Area Flow
gpm (I/mm) ft. x ft.(m x m)
Pressure
psi (bar)
Deflector to
Ceiling Distance
12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48)
1 t 4 inches
(25 to 100 mm)
14 X 14(4.3 x 4.3) 10(38) 11.0(0.76)
15 x 15(4.6 x 4.6) 12(45) 16.0(1.1)
16x 16 (4.9x4.9) 13(49) 18.8(l.3)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 2of 15
October 2019 www.reliablesprinkler.com
Technical Specifications Finishes
Style: Pendent and Recessed Pendent (See Table N)
Threads: 1/2" NPT or 1507-1R1/2
Nominal K-Factor: 4.9 (71 metric) Temperature Ratings
Max. Working Pressure: 175 psi (12 bar) 155°F (68°C)
175°F (79°C)
Material Specifications
Thermal Sensor: 3 mm glass-bulb Recessed Escutcheons
Sprinkler Frame: Brass Alloy Fl Recessed
Button: Copper Alloy F2 Recessed
Sealing Assembly: Nickel Alloy with PTFE FV Recessed*
Load Screw: Bronze Alloy
Deflector: Bronze Alloy Sprinkler Wrenches
Model W2
Model GFR2_(Recessed)
* Model FV escutcheons are not for use in positively pressurized ceiling plenums.
Model F1Res4.9 Residential Pendent Sprinkler Components and Installation Dimensions sIuiiW
2-1/4" (57mm) 2-1/4" (57mm) hT- DIA. -Th Face of fittina DIA. Face of tittinn
to finished 1-15/16" to finished
ceiling (49mm) DIA. ceiling
5/8" (16mm) 1/2"(l3mm)
i-/- 3/8" (9mm) +/- 1/4(6mm)
(8" (41 mm) +/-
3/8" (9mm) w' 1/4" (6mm) '
I 1-3/4" (44mm) +1-
2-7/8" (72mm. L
F2 & FV Recessed Escutcheon Installation Dimensions Fl Recessed Escutcheon Installation
Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria 111i
Minimum Flow and Residual Pressure in Wet Pipe Systems111
Maximum Coverage Area(2)
ft. x ft. (m x m)
Flow
gpm (I/mm)
Pressure
psi (bar)
Deflector to
Ceiling Distance
12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48)
1 t 4 inches
(25 to 100 mm)
14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48)
16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48)
18 x 18(5.5 x 5.5) 17(64) 12.0(0.83)
20x20(6.1x6.1) 20(76) 16.7(1.15)
12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65)
4 to 8 inches
(100 to 200 mm)
14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74)
16 x 16(4.9 x 4.9) 17 (64) 12.0 (0.83)
18 x 18(5.5 x 5.5) 19(72) 15.0(1.03)
20 x 20(6.1 x 6.1) 22(83) 20.2(1.39)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 3of 15
October 2019 . www.reliablesprinkler.com
Technical Specifications
Style: Pendent and Recessed Pendent
Threads: 1/2" NPT or 1S07-1R1/2
Nominal K-Factor: 5.8 (84 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
175°F (79°C)
Recessed Escutcheons
Fl Recessed
F2 Recessed
FV Recessed*
Sprinkler Wrenches
Model W2
Model GFR2 (Recessed)
('cTT
* Model FV escutcheons are not for use in positively pressurized ceiling plenums.
Model F1Res58 Residential Pendent Sprinkler Components and Installation Dimensions
2-1/4' (57mm) . 2-1/4" (57mm)
DIA. -r Face of fitting DIA. -r Face of fitting
1 15/16 to finished
ceiling 115/160 1
to finished
4(4
iD
"lmA (49mm) IA. ceiling
5/8" (16mm) 1/2"(l3mm)
3/8" (9mm) +/- 1/4(6mm)
1-5/8' (41mm) +1 1 3/4 (44mm)
2-1/4"
(57)
(6mm)
(32mm) L2718 (72mm) DlA.
-3/8" (9mm)
-2-8n72mm
-
Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation
Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems1'
Maximum Coverage Area(2)
ft. x ft. (m x m)
Flow
gpm (I/mm)
Pressure
psi (bar)
Deflector to
Ceiling Distance
16x 16(4.9x4.9) 16(61) 7.6 (0.52)
1 to 4 inches
(25 to 100 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75)
20 x 20 (6.1 x 6.1) 22(83) 14.4(1.0)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 4 of 15
October 2019 . www.reliablesprinkler.com
Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent
Threads: 3/4" NPT or IS07-1R3/4 Temperature Ratings Nominal K-Factor: 7.6 (109 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°c)
Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed*
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2
Model GFR2 (Recessed)
* Model FV escutcheons are not for use in positively pressurized ceiling plenums.
Model Fl Res76 Residential Pendent Sprinkler Components and Installation Dimensions
2-1/4° (57mm)
DIA.
1-15/16"
(49mm) DIA:
Face of fitting
to finished
ceiling
5/8° (16mm)
+1- 3/8°(9mm)
1-5/8"(41 mm) +/-
3/8° (9mm)
2-1/4' (57mm)
DIA.
1-15/16"
(49mm) DIA.
Face of fitting
to finished
ceiling
1/2" (13mm)
+1- 1/4" (6mm)
1-3/4° (44mm) +1-
1/4° (6mm)
ro3s 2-1/4°
(57)
1-5/8"
(44mm)
Dimensions
2-7/8 (72mm) DIA. 2-7/8" (72mm) DIA.
Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation
Model Fl Res76 Residential Pendent Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems()
Maximum Coverage Area121 Flow Pressure Deflector to
ft. x ft. (m x m) gpm (I/mm) psi (bar) Ceiling Distance
18 x 18 (5.5 x 5.5) 21(80) 7.6 (0.52)
1 t 4 inches
(25 to 100 mm)
20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 5 of 15
October 2019 www.reliablesprinkler.com
Technical Specifications
Style: Conical Concealed Pendent and
Recessed Pendent
Threads: 1/2" NPT or 1S07-1R1/2
Nominal K-Factor: 3.0 (43 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
Recessed Escutcheons/Cover Plates
CCP Conical Concealed Plate 135°F (570C)*
FP Recessed*
Sprinkler Wrenches
Model GFR2
*Note: Model FP escutcheons and COP cover plates are not listed for use in positively pressurized ceiling plenums.
Model Fl Res3O CCP and FP Recessed Pendent Sprinkler Installation Dimensions
')IQ" ' IOO
ace of fitting
to finished
ceiling
-1/4' (32mm)
/- 1/4" (6mm)
15/16
(24mm)
Face of fitting
to finished
ceiling
1-1/4' (32mm)
+1- 1/4" (6mm)
- 1(25mm)
+1- 1/4" (6mm)
CCP Recessed Escutcheon Installation
FP Recessed Escutcheon Installation
Model FlRes30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems(')
Maximum Coverage AreaM
ft. x ft. (m x m)
Flow
I gpm (I/mm)
I Pressure
I psi (bar) I Deflector to Ceiling Distance
12 X 12 (3.7 X 3.7) 8(30) 7.0(0.48) 1/2 to 1 inch
(13 to 25 mm) 14 x 14(4.3 x 4.3) 11(38) 13.4(0.92)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
The sprinkler must be installed into a ceiling with the listed cover plate installed.
Bulletin 135 Page 6of15
October 2019 www.reliablesprinkler.com
,)_ciclu I7n,,,.1
CCP Recessed Escutcheon Installation
Technical Specifications
Style: Conical Concealed Pendent and
Recessed Pendent
Threads: 1/2 NPT or 1S07-1R1/2
Nominal K-Factor: 4.9 (71 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
Recessed Escutcheons/Cover Plates
CCP Conical Concealed Plate 135°F (570C)*
FP Recessed*
Sprinkler Wrenches
Model GFR2
*Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums.
Model Fl Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions
2-5/8 (67mm)
DIA.
2-5/16°
(59mm)DIA.
ace of fitting
to finished
ceiling
-1/4" (32mm)
_________ /- 1/4°(6mm)
I I Face of fitting
to finished
ceiling I 1-1/4°(32mm)
1/4° (6mm) ,,,,,,,
I
(24mm) +/-1/4°(6rnrn)
L3-3/16" (78mm) DIA. .
FPRecessedEscutcheonInstallation
Model F1Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems111
Maximum Coverage Area()
ft. x ft. (m x m)
Flow
gpm (I/mm)
Pressure
psi (bar) Deflector to Ceiling Distance
14x14(4.3x4.3) 13(49) 7.0(0.48)
1/2 to inch
(13 to 25 mm)
16.7(1.15)
16 X 16(4.9 X 4.9) 14(53) 8.2(0.57)
18 x 18 (5.5 x 5.5) 18(68) 13.5(0.93)
20 x 20 (6.1 x 6.1) 20(76)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
The sprinkler must be installed into a ceiling with the listed cover plate installed.
Bulletin 135 Page 7 of 15
October 2019 www.reliablesprinkler.com
CCP Recessed Escutcheon Installation
Technical Specifications
Style: Conical Concealed Pendent and
Recessed Pendent
Threads: 1/2" NPTor lS07-1R1/2
Nominal K-Factor: 5.8 (84 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
Recessed Escutcheons/Cover Plates
CCP Conical Concealed Plate 135°F (570C)*
FP Recessed*
Sprinkler Wrenches
Model GFR2 (Recessed)
*Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums.
Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions
2-5/8k (67mm) 2-5/8" (67mm) I DIA. 1 I I DIA. 1 I
2-5/16"
(59mm)DIA.
ace of fitting
ceiling
to finished
I I I I Face of fitting
to finished
ceiling I r-1
1/4(32mm) 1/4 (32mm) kl
-1/4(6mm) 1/4(6mm)
24mm) +/-1/4(6mrn)
L3-3/16" (78mm) DIA.
FP Recessed Escutcheon Installation
Model F1Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systemst
Maximum Coverage Area()
ft. x ft. (m x m)
Flow gpm
(I/mm)
Pressure psi
(bar)
Deflector to Ceiling
Distance
16x 16(4.9x4.9) 16(61) 7.6 (0.52)
1/2 to 1 inch
(13 to 25 mm)
18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75)
20 x 20(6.1 x 6.1) 22(83) 14.4(1.0)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
The sprinkler must be installed into a ceiling with the listed cover plate installed.
Bulletin 135 Page 8 of 15
October 2019 www.reliablesprinkler.com
,-)_c/p"
CCP Recessed Escutcheon Installation
Technical Specifications
Style: Conical Concealed Pendent and
Recessed Pendent
Threads: 3/4' NPT or 1S07-1 133/4
Nominal K-Factor: 7.6 (109 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
Recessed Escutcheons/Cover Plates
CCP Conical Concealed Plate 135°F (570C)°
FP Recessed*
Sprinkler Wrenches
Model GFR2 (Recessed)
*Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums.
Model Fl Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions
2-5/8' (67mm)
DIA.
2-5/16"
(59mm)DIA.
ace of fitting
to finished
ceiling
-1/4(32mm)
I- 1/4" (6mm)
I I ____________________________________
1 I Face of fitting
to finished
ceiling
1-1/4(32mm)
1/4(6mm)
I
______
+/-1/4(6rnm)
L3-3/18" (78mm) DIA. -
FP Recessed Escutcheon Installation
Model F1Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems")
Maximum Coverage Area Flow Pressure
Deflector to Ceiling Distance
ft.x ft. (mxm) gpm(I/mm) psi(bar)
16 x 16 (4.9 x 4.9) 21(80) 7.6(0.52)
1/2 to 1 inch
(13 to 25 mm) 18x18(5.5x5.5) 22(83) 8.4(0.58)
20 x 20 (6.1 x 6. 1) 25(95) 10.8(0.75)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
The sprinkler must be installed into a ceiling with the listed cover plate installed.
Bulletin 135 Page 9 of 15
October 2019 www.reliablesprinkler.com
Technical Specifications
Style: Sidewall and Recessed Sidewall
Threads: 1/2' NPTor lS07-1R1/2
Nominal K-Factor: 4.4 (63 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
175°F (79°C)
Recessed Escutcheons
F2 Recessed
FV Recessed
Sprinkler Wrenches
Model W2
Model GFR2 (Recessed)
Model Fl Res44 Horizontal Sidewall Sprinkler Installation Dimensions
Face of fitting
to finished wall ic,a" (A1,,,, '•, '-• .......F
3/8" (10mm) +1- 1/4" (6mm)
+1- 1/4" (6mm)
2-1/4" 1-15/16"
(57mm) (49mm) -
-i
DIA.
Top of Deflector Down from
Ceiling to be Either 4" to 6"
(100 to 150 mm)or 6" to 12"
(150 to 300 mm) Based on
Hydraulic Calculations
(8mm)
Dimensions F2 & FV Recessed Escutcheon Installation
Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems111
Maximum Coverage Area'
ft. x ft. (m x m)
Flow
gpm (I/mm)
Pressure
psi (bar)
Deflector to
Ceiling Distance 7 12 x 12(3.7 x 3.7) 12(45) 7.5 (0.52)
(l00 : 1 50 mm)
18.7(1.29)
14 x 14(4.3 x 4.3) 14(53) 10.2 (0.70)
15 x 15(4.6 x 4.6) 15(57) 11.6(0.80)
16 x 16(4.9 x 4.9) 16(61) 13.3 (0.92)
16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16)
16 x 20(4.9 x 6.1) 23(87) 27.4(1.89)
18 x 18 (5.5 x 5.5) 19(72)
12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7)
6 to 12 inches
(150t0300 mm)
27.4(1.89)
14 x 14(4.3 x 4.3) 16(61) 13.2(0.91)
15 x 15(4.6 x 4.6) 16(61) 13.2(0.91)
16 x 16(4.9 x 4.9) 17(64) 15.0 (1.03)
16 x 18(4.9 x 5.5) 20(76) 20.7(1.43)
16 x 20(4.9 x 6.1) 23 (87)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 10 of 15
October 2019 www.reliablesprinkler.com
Technical Specifications
Style: Conical Concealed Sidewall
Threads: 1/2' NPT or ISO 7-1 R1/2
Nominal K-Factor: 4.4 (63 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass-bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F(68°C)
1750F(790C)(1)
Cover Plates SWC
SWC Conical Concealed Plate(')
SWC-2 (Slotted) Conical Concealed Plate (3)
Sprinkler Wrenches
Model GFR2 SWC-2
Note:
11 Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating.
21135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers
3 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers
Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions
V (25mm) V (25mm)
+1- 1/4" (6mm) +1- 1/4 (6mm)
Face of fitting
to finished wall
2-7/16'(62mm)-----
- 2-5/8" Top of Deflector Down 5/16
(67mm) (58mm) - - -
:- from ceiling to be Either (84mm) DIA. DIA.
2
150mm) or 6t0 12 DlA.
(150mm to 300mm)
18mm)
-------t06"(100mmt0
Based on Hydraulic
Calculations
N—(41mm)
15/8!.
Dimensions SWC & SWC-2 Concealed Cover Plate Installation
Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems011
Maximum Coverage Area()
ft. x ft. (m x m)
Ordinary Temperature Rating
155°F (68°C)
Intermediate Temperature Rating
175°F (79°C) Deflector to Ceiling
Distance
psi (bar)
Flow
gpm (I/mm)
Pressure
psi (bar)
Flow
gpm (I/mm)
Pressure
12 x 12(3.7 x 3.7) 13(49) 8.7 (0.60) 14(53) 10.2 (0.7)
14 x 14(4.3 x 4.3) 14(53) 10.2 (0.7) 14(53) 10.2 (0.7)
15x 15(4.6x4.6) 16(61) 13.2 (0.91) -- 4to6 inches
(100 to 150 mm) 16 x 16(4.9 x 4.9) 17(64) 15.0 (1.03) -- --
16x 18(5.5 x5.5) 19(72) 18.7(l.31) -- --
16 x 20 (4.9 x 6.1) 23 (87) 27.4(l.89) - - - -
12x 12(3.7x3.7) 14(53) 10.2 (0.7) -- --
14x 14(4.3x4.3) 15(57) 11.7 (0.81) -- --
6 to 12 inches
(150 to 300 mm) 15x 15(4.6x4.6) 17(64) 15.0 (1.03) --
--
16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- --
16x 18(4.9x5.5) 20(76) 20.7(l.43) -- --
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 11 of 15
October 2019 RMO www.reliablesprinkler.com
Technical Specifications
Style: Sidewall and Recessed Sidewall
Threads: 1/2" NPT or 1507-1R1/2
Nominal K-Factor: 5.8 (84 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
175°F (79°C)
Recessed Escutcheons
F2 Recessed
FV Recessed
Sprinkler Wrenches
Model W2
Model GFR2 (Recessed)
Model Fl Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions _IuIi
Face of fitting
to finished wall 1-5/8" (41mm)
3/8(10mm) +/- 1/4(6mm)
+1- 1/4" (6mm)
2-7/16"(62mm)
2-1/4° 1-1/16°
5/16 j (8mm)
(57mm)
DIA.
(49mm)
DIA.
Top of Deflector Down from
Ceiling to be Either 4 to 6"
(100 to 150 mm) or6to 12"
(150 to 300 mm) Based on
Hydraulic Calculations
Dimensions F2 & P/ Recessed Escutcheon Installation
Model F1Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems1'
Maximum Coverage Area(2)
ft. x ft. (m x m)
Flow
gpm (I/mm)
Pressure
psi (bar)
Deflector to
Ceiling Distance
12 x 12(3.7 x 3.7) 16(61) 7.6 (0.52)
4 to 6 inches
(100 to 150 mm)
25.0(1.72)
14 x 14(4.3 x 4.3) 18 (68) 9.7 (0.66)
15 X 15(4.6 X 4.6) 19(72) 10.7 (0.74)
16x 16(4.9x4.9) 21 (80) 13.2 (0.91)
16x 18(5.5x5.5) 25(95) 18.6(1.28)
16 x 20 (4.9 x 6.1) 29(110)
12 x 12(3.7 x 3.7) 22(83) 14.4(l.0)
6 to 12 inches
(150t030mm)
28.6(l.97)
14x 14(4.3x4.3) 22(83) 14.4(l.0)
15 x 15 (4.6 x 4.6) 24(91) — 17.1 (1.18)
16x 16(4.9x4.9) 26(98) 20.1 (1.39)
16 x 18(4.9x 5.5) 31 (117)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 12of15
October 2019 RONNOW44 www.reliablesprinkler.com
Technical Specifications
Style: Sidewall and Recessed Sidewall
Threads: 1/2' NPT or 1507-1R1/2
Nominal K-Factor: 5.8 (84 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm glass bulb
Sprinkler Frame: Brass Alloy
Button: Copper Alloy
Sealing Assembly: Nickel Alloy with PTFE
Load Screw: Bronze Alloy
Deflector: Bronze Alloy
Finishes
(See Table N)
Temperature Ratings
155°F (68°C)
175°F (79°C)
Recessed Escutcheons
F2 Recessed
FV Recessed
Sprinkler Wrenches
Model W2
Model GFR2 (Recessed)
Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions
Face of fitting
to finished wall 1-7/8 (48mm)
3/8(10mm) +1- 1/4" (6mm)
+1- 1/4" (6mm)
-2-7/8 (73mm) -
6J (8mm)
2-1/4" 1-15/16' 1 Top of Deflector Down From
(57mm) (49mm) Ceiling to be Either 4' to 6"
DIA. DIA. (100 to 150 mm) or&'to 12'
(150 to 300 mm) Based on
Hydraulic Calculations
Dimensions F2 &FV RecessedEscutcheonInstallation
Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria
Minimum Flow and Residual Pressure in Wet Pipe Systems(')
Maximum Coverage Area(2)
ft.x ft. (mxm)
Flow
gpm(I/mm)
Pressure
psi(bar)
Deflector to
CeilingDistance
18 x 20 (5.5 x 6. 1) 30(114) 26.8(1.85)
4 to 6 inches
(100 to 150 mm)
52.4(3.63)
20 x 20 (6.1 x 6. 1) 30(114) 26.8(1.85)
16x22(4.9x6.7) 33(125) 32.4(2.23)
16x24(4.9x7.3) 38(144) 42.9(2.96)
14x26(4.3x7.9) 42(160)
18 x 20 (5.5 x 6. 1) 35(133) 36.4(2.51)
6 to 12 inches
(150 to 300 mm)
62.9(4.34)
16 X 22(4.9x6.7) 38(144) 42.9(2.96)
16 x 24 (4.9 x 7.3) 42(160) 52.4(3.61)
14 x 26 (4.3 x 7.9) 46(174)
Notes:
For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2)the flow required to
achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler.
For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed.
Bulletin 135 Page 13 of 15
October 2019 www.reliablesprinkler.com
Finishes Flelrao
Standard Finishes Special Application Finishes
Sprinkler'" Fl, F2. FV FP3, CCP, SWC (Conical) Sprinkler (1) Fl, F2. FV FPM, CCP, SWC (Conical)
Escutcheons Cover Plates (l) Escutcheons Cover Plates (1)
Bronze Brass -- Bright Brass Bright Brass Bright Brass
Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome
White White White Paint Black Black Black Paint Polyester (2) Polyester Polyester (2) Polyester
-- -- --
Custom Color Custom Color Custom Color Paint Polyester Polyester
Electroless Nickel -- --
-- PTFE (2) -- --
Notes:
Paint or any other coating applied over the factory finish will void all approvals and warranties.
cULus Listed Corrosion Resistant.
The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring.
Installation
Models Fl Res sprinklers are to be installed as shown in this
bulletin. Model Fl, F2, FV, and FP recessed escutcheons
are the only recessed escutcheons to be used with Model
Fl Res sprinklers. Not all Fl Res sprinklers may be used with
all recessed escutcheons offered. Confirm listing of escutch-
eon type for use with individual sprinklers. Use of any other
recessed escutcheon will void all approvals and warranties.
For installing Model Fl Res sprinklers, use only the Model
W2 sprinkler Wrench; for installing Models F1 Res Recessed
Pendent, Sidewall, Conical Concealed Pendent (CCP), and
Sidewall Concealed (SWC and SWC-2) sprinklers use only
the Model GFR2 sprinkler wrench. Use of wrenches other than
those specified may damage these sprinklers.
Model GFR2
Installation of Fl Res sprinklers in a wall or ceiling will require
a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed
escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons,
CCP, SWC, and SWC-2 cover plates.
Install Fl Res HSW sprinklers with a ceiling to deflector dis-
tance that complies with the hydraulic design criteria tables in
this bulletin. The flow arrow on deflector must point away from
near wall and "Top" marking must face the ceiling.
A 'leak tight" sprinkler joint can be obtained with the following
torque:
1/2" NPT and lS07-1R1/2: 8-18 ft-lbs (11 —24 N-m)
3/4" NPT and lS07-1R3/4: 14-20 ft-lbs (19-27 N-m)
Do not tighten sprinklers over maximum recommended torque.
This may cause leakage or impairment of the sprinklers.
Do not install any glass bulb sprinklers where the bulb is
cracked or there is a loss of liquid from the bulb.
Glass bulb sprinklers have orange bulb protectors to mini-
mize bulb damage during shipping, handling and installation.
Remove this protection at the time the sprinkler system is
placed in service. Removal of the protectors before this time
may leave the bulb vulnerable to damage. RASCO wrenches
are designed to install sprinklers when protectors are in place.
Remove protectors by undoing the clasp by hand. Do not use
tools to remove the protectors.
Maintenance
Reliable Model F1 Res Sprinklers should be inspected and the
sprinkler system maintained in accordance with NFPA 25, 13,
13D, and 13R, as well as the requirements of any Authorities
Having Jurisdiction.
Prior to installation, sprinklers should remain in the original
cartons and packaging until used. This will minimize the
potential for damage to sprinklers that could cause improper
operation or non-operation.
Do not clean sprinklers with soap and water, ammonia liquid
or any other cleaning fluids. Remove dust by gentle vacuum-
ing without touching the sprinkler.
Replace any sprinkler which has been painted (other than
factory applied). Properly installed CCP, SWC, and SWC-2
cover plates will have an air gap that is required for proper
operation, do not seal the gap or paint the cover plates.
Model W2
Bulletin 135 Page 14 of 15
October 2019 www.reliablesprinkler.com
Replace any sprinkler which has been damaged, where
cracks are observed in the glass bulb, or when liquid has
been lost from the glass bulb.
A stock of spare sprinklers should be maintained to allow
quick replacement of damaged or operated sprinklers.
Failure to properly maintain sprinklers may result in inadver-
tent operation or non-operation during a fire event.
Listings & Approvals
Listed by Underwriters Laboratories Inc. and UL Certified for
Canada (cULus)
Guarantee
For Reliable Automatic Sprinkler Company guarantee, terms,
and conditions, visit www.reliablesprinkler.com.
Patents
For patents applicable to products contained in this technical
bulletin, please visit www.r-s.co
Ordering Information
Specify the following when ordering:
Sprinkler
Model (See Table A)
Temperature Rating
Threads (NPT or 1507-1)
Finish (See Table N)
Escutcheon or Cover Plate
Model
Finish (See Table N)
Sprinkler Wrench
Model W2 (Pendent and HSW)
GFR2 (Recessed and Concealed)
Bulletin 135 135 Page 15 of 15
October 2019 www.reliablesprinkler.com