HomeMy WebLinkAbout2736 ARLAND RD; ; FPR2020-0041; Permit[F1 City of Carlsbad Fniiaeimi1t Print Date: 01/05/2021 Job Address: 2736 ARLAND RD, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 1561425600 Track #: Valuation: $259,738.44 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2020-0041 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 05/28/2020 Issued: 06/16/2020 DEV2019-0137 Finaled Close Out: 01/05/2021 Inspector: Final Inspection: Project Title: LIN RESIDENCE Description: LIN RESIDENCE -NEW 13D SPRINKLER SYSTEM FOR SFR (24 HEADS) Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 12155 PAINE PL 12155 PAINE PL P0 WAY, CA 92064-7154 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov ffc2o2-o -• I alaFA TL& VrWW ISPFSlSI1E • • 12 155 PANE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR L1N RESIDENCE FILE NUMBER: 20-0374.SDF DATE: MAY 21, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm! 512 sq.ft. AREA OF APLICATION: 2nd FLOOR COVERAGE PER SPRINKLER: 256 sq.ft. NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 26.4 gpm TOTAL WATER REQUIRED (including hose): 31.4 gpm FLOW AND PRESSURE (@ BOR): 26.4 gpm @ 33.1 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT CONTACT: CHRIS (760) 602-2750 WATER PRESSURE INFORMATION: 66 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf JOB DITLE: LIN RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 59.4 58.0 500.0 59.4 31.4 57.1 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 8.0 SOURCE 57.1 31.4 2 10.0 - - - - 50.1 - - - 3 10.0 - - - - 46.1 - - - 3A 0.0 - - - - 40.1 - - - 4 0.0 - - - - 37.9 - - - 5 2.0 HOSE STREAM 33.1 5.0 6 10.5 - - - - 19.5 - - - 7 10.5 - - - - 17.4 - - - 8 23.0 - - - - 12.0 - - - 8A 22.5 - - - - 12.2 - - - 9 25.5 - - - - 7.1 - - - 9A 22.5 K= 4.90 7.0 13.0 10A 23.5 K= 4.90 7.5 13.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf JOB ITLE: LIN RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.4 0.995 PL 15.00 PF 6.2 1 8.0 SRCE 57.1 (N/A) 13.0 150 FTG TG PE -0.9 2 10.0 0.0 50.1 0.0 0.257 TL 24.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 10.0 0.0 50.1 0.0 4.0 psi, 31.4 gpm 3 10.0 0.0 46.1 0.0 Pipe: 3 31.4 1.360 PL 165.00 PF 10.2 3 10.0 0.0 46.1 0.0 6.9 150 FTG 9L PE 4.3 3A 0.0 0.0 40.1 0.0 0.056 TL 183.00 PV Pipe: 4 31.4 1.025 PL 5.00 PF 2.2 3A 0.0 0.0 40.1 0.0 12.2 150 FTG EL PE 0.0 4 0.0 0.0 37.9 0.0 0.222 TL 10.00 PV Pipe: 5 31.4 1.101 PL 9.00 PF 3.9 4 0.0 0.0 37.9 0.0 10.6 150 FTG ET3RC PE -0.9 5 2.0 H.S. 33.1 5.0 0.157 TL 25.00 PV Pipe: 6 26.4 1.101 PL 45.50 PF 9.9 5 2.0 H.S. 33.1 5.0 8.9 150 FTG 3E4TR PE -3.7 6 10.5 0.0 19.5 0.0 0.114 TL 87.50 PV Pipe: 7 26.4 1.101 PL 10.00 PF 2.2 6 10.5 0.0 19.5 0.0 8.9 150 FTG E2R PE 0.0 7 10.5 0.0 17.4 0.0 0.114 TL 19.00 PV Pipe: 8 0.0 1.101 PL 24.50 PF 0.0 7 10.5 0.0 17.4 0.0 0.0 150 FTG 2ET3R PE -5.4 8 23.0 0.0 12.0 0.0 0.000 TL 46.50 PV Pipe: 9 0.0 1.101 PL 0.50 PF 0.0 8 23.0 0.0 12.0 0.0 0.0 150 FTG TR PE 0.2 8A 22.5 0.0 12.2 0.0 0.000 TL 6.50 PV Pipe: 10 26.4 1.101 PL 16.50 PF 3.8 7 10.5 0.0 17.4 0.0 8.9 150 FTG 2E3R FE -6.5 9 25.5 0.0 7.1 0.0 0.114 TL 33.50 PV Pipe: 11 13.0 1.101 PL 9.50 PF 1.3 9 25.5 0.0 7.1 0.0 4.4 150 FTG 4ETR PE 1.3 9A 22.5 4.9 7.0 13.0 0.031 TL 43.50 PV Pipe: 12 13.4 1.101 PL 2.00 PF 0.5 9 25.5 0.0 7.1 0.0 4.5 150 FTG ETR PE 0.9 10A 23.5 4.9 7.5 13.4 0.032 TL 15.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf JOB 1'ITLE: LIN RESIDENCE TWO HEAD CALC NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.010 gpm and a maximum imbalance at any node of 0.122 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 13.0 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 59.39 psi with a flow of 32.13 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/21/2020 C:\program fiies\HRS Systems\hass87\HASS DATA\20-0374.sdf 'JOE TITLE: LIN RESIDENCE TWO HEAD CALC PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf JOB TITLE: LIN RESIDENCE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 59.40 psi Resid: 58.00 psi Flow: 500.0 gpm 70.0 60.0 G 1 A 2 U 50.0 G E 40.0 P R E S 30.0 S U R 20.0 E 10.0 p S 0.0 -14.7 LEGEND Available pressure 59.39 psi @ 31.4 gpm Required pressure 57.08 psi @ 31.4 gpm Source Supply Curve System Demand Curve 100150 200 250 300 350 400 450 500 FLOW (GPM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/21/2020 C:\program files\HRS Systems\hass87\HASS DATA\20-0374.sdf JOB TITLE: LIN RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 600\\\\\\\\ I \\\\\\\\\ x * <-58.0 psi @ 500 gpm Flow Test Point 55+ 50+ 45+ P 40+ R I E I S I S 35+ U I R I E 30+ P I S I I 25+ ) I 20+ 15+ 10+ LEGEND I 'V I X = Required Water Supply I 57.08 psi 8 31.4 gpm 5+ It 0 = Available Water Supply 59.39 psi 8 31.4 gpm It 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) ff 7A !FW RESPNISIE • • 12 155 PAINE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR LIN RESIDENCE FILE NUMBER: 20-0374.SDF DATE: MAY 21, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ BOR): SPRINKLER ORIFICE SIZE: RESIDENTIAL .05 gpm/ 400 sq.ft. M. BATHROOM 400 sq.ft. 1 SPRINKLER 21.0 gpm 26.0 gpm 21.0 gpm @39.1 psi l!2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD MUNICIPAL WATER DEPARTMENT CONTACT: CHRIS (760) 602-2750 WATER PRESSURE INFORMATION: 66 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF JOB TITLE: LIN RESIDENCE ONE HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 59.4 58.0 500.0 59.4 26.0 56.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 8.0 SOURCE 56.4 26.0 2 10.0 - - - - 51.2 - - - 3 10.0 - - - - 47.2 - - - 3A 0.0 - - - - 44.3 - - - 4 0.0 - - - - 42.8 - - - 5 2.0 HOSE STREAM 39.1 5.0 6 10.5 - - - - 28.9 - - - 7 10.5 - - - - 27.5 8 23.0 - - - - 18.6 - - - 8A 22.5 K= 4.90 18.4 21.0 9 25.5 - - - - 21.0 - - - 9A 22.5 - - - - 22.3 - - - 10A 23.5 - - - - 21.9 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF JOB TITLE: LIN RESIDENCE ONE HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 26.0 0.995 PL 15.00 PF 4.3 1 8.0 SRCE 56.4 (N/A) 10.7 150 FTG TG PE -0.9 2 10.0 0.0 51.2 0.0 0.181 TL 24.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 10.0 0.0 51.2 0.0 4.0 psi, 26.0 gpm 3 10.0 0.0 47.2 0.0 Pipe: 3 26.0 1.360 PL 165.00 PF 7.2 3 10.0 0.0 47.2 0.0 5.7 150 FTG 9L PE 4.3 3A 0.0 0.0 44.3 0.0 0.040 TL 183.00 PV Pipe: 4 26.0 1.025 PL 5.00 PF 1.6 3A 0.0 0.0 44.3 0.0 10.1 150 FTG EL PE 0.0 4 0.0 0.0 42.8 0.0 0.157 TL 10.00 PV Pipe: 5 26.0 1.101 PL 9.00 PF 2.8 4 0.0 0.0 42.8 0.0 8.8 150 FTG ET3RC PE -0.9 5 2.0 H.S. 39.1 5.0 0.111 TL 25.00 PV Pipe: 6 21.0 1.101 PL 45.50 PF 6.5 5 2.0 H.S. 39.1 5.0 7.1 150 FTG 3E4TR PE -3.7 6 10.5 0.0 28.9 0.0 0.074 TL 87.50 PV Pipe: 7 21.0 1.101 PL 10.00 PF 1.4 6 10.5 0.0 28.9 0.0 7.1 150 FTG E2R PE 0.0 7 10.5 0.0 27.5 0.0 0.074 TL 19.00 PV Pipe: 8 21.0 1.101 PL 24.50 PF 3.5 7 10.5 0.0 27.5 0.0 7.1 150 FTG 2ET3R PE -5.4 8 23.0 0.0 18.6 0.0 0.074 TL 46.50 PV Pipe: 9 21.0 1.101 PL 0.50 PF 0.5 8 23.0 0.0 18.6 0.0 7.1 150 FTG TR PE 0.2 8A 22.5 4.9 18.4 21.0 0.074 TL 6.50 PV Pipe: 10 0.0 1.101 PL 16.50 PF 0.0 7 10.5 0.0 27.5 0.0 0.0 150 FTG 2E3R PE -6.5 9 25.5 0.0 21.0 0.0 0.000 TL 33.50 PV Pipe: 11 0.0 1.101 PL 9.50 PF 0.0 9 25.5 0.0 21.0 0.0 0.0 150 FTG 4ETR PE 1.3 9A 22.5 0.0 22.3 0.0 0.000 TL 43.50 PV Pipe: 12 0.0 1.101 PL 2.00 PF 0.0 9 25.5 0.0 21.0 0.0 0.0 150 FTG ETR PE 0.9 10A 23.5 0.0 21.9 0.0 0.000 TL 15.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF JOB TITLE: LIN RESIDENCE ONE HEAD CALC NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.065 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 59.39 psi with a flow of 26.74 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF JOB TITLE: LIN RESIDENCE ONE HEAD CALC PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/21/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF JOB TITLE: LIN RESIDENCE ONE HEAD CALC WATER SUPPLY ANALYSIS Static: 59.40 psi Resid: 58.00 psi Flow: 500.0 gpm 70.0 LEGEND Available pressure 60.0 G 1 A 2 U 50.0 G E 40.0 P R E 30.0 S U R 20.0 E 59.39 psi @ 26.0 gpm Required pressure 56.43 psi @ 26.0 gpm Source Supply Curve System Demand Curve 10.0 p S i 0.0 -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/21/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0374.SDF JOB TITLE: LIN RESIDENCE ONE HEAD CALC WATER SUPPLY CURVE 600\\\\\\\\ I \\\\\\\\\ I * <-58.0 psi @ 500 gpm X Flow Test Point 55+ 50+ 45+ P 40+ R I E I S I 5 35+ U I R I E I 30+ P I S I I 25+ 20+ 15+ 10+ LEGEND I 'I I X = Required Water Supply 56.43 psi @ 26.0 gpm 5+ I 0 = Available Water Supply 59.39 psi @ 26.0 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) Model RFC43 & RFC43LL Model RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 January 2020 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classificationand are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model CS Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. c/I Model RFC76 Model RFC & G5 Cover Plate Sprinkler Model Nominal K-Factor gpm/p5i112 (I/mm/bar112) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20x20(6.1 x6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613 RFC76 7.6(109) 20x20(6.1 x6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1 /2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Bottom View Model RFC30 & RFC30LL Sprinkler Components and Dimensions I 2-5/16° (58 mm) Threads Body Cup Tower 1-3/4° (44 mm) +1- 1/4(6 mm) _ Ii Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 3/16(5 mm) I II Pin (extended) I I Deflector (extended) Model G4/G5 Cover Plate 3-5/16 (84 mm) Dia. Ceiling Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) 7 Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 2 of 8 January 2020 MINNNORM www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Model RFC43 & RFC43LL Sprinkler Components and Dimensions I 2-5/16' (58 mm) Threads Dia. Body Cup Tower .7 1-3/4" (44 mm) ~1- 1/4° (6 mm) Nominal face of fitting to ceiling Fusible Link Deflector (retracted)3 /16°(5 mm) ____________ •f \\\'''\ ____________ .-J I II Pin (extended) Deflector (extended) --u' Model G4/G5 Cover Plate 3-5/16° (84 mm) Dia. Ceiling Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure111 Max. Coverage Area (2) Ordinary Temperature ___________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16x16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) -- -- 20x20 21 23.8 (6,1x6.1) (79) (1.64) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 3 of 8 January 2020 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC (without wrench-able cap) Deflector: Bronze Alloy Model W3 (with wrench-able cap) Bottom View Cup: Steel Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL onlv) Model RFC49 & RFC49LL Sprinkler Components and Dimensions _J.LuI Threads F- 2-5/16(58 mm) Dia. Body _________________________ Cup Tower 1-3/4"(44 mm) +1- 1/4° (6 mm) Deflector (retracted) retr Fusible Link Nominal face of fitting to ceiling _ -ju- _________ 3/16"(5 mm) Pin (extended) Deflector (extended) AT—Ceiling Model G4/G5 Cover Plate 3-5/16' (84 Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) 77 Max. Coverage Area (2) Ordinary Temperature __________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 4 of 8 January 2020 www.reliablesprinkler.com Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler. 165°F (74°C) cover plate Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Bottom View Model RFC58 Sprinkler Components and Dimensions Threads — Body Cup Tower -... Fusible Link — Deflector (retracted) Pin (extended) Deflector (extended) - 1-7/8° (48 mm) +1- 3/8(9 mm) Nominal face of fitting to ceiling L...... 2-5/16(58 mm) Dia. ,,,,,,,_•[ 3/16(5mm) Model G4/G5 Cover Plate 3-5/16° (84 mm) Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria rnri Minimum Flow and Residual Pressure 1) Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5x5.5) (68.1) (0.66) 20x20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 5 of 8 January 2020 NO A www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Bottom View Model RFC76 Sprinkler Components and Dimensions 2-5/16"(58 mm) Threads — Body Cup Tower -. Fusible Link — Deflector (retracted) Pin (extended) Deflector (extended) — Dia. 1-7/8' (48 mm) +/- 3/8° (9 mm) Nominal face of fitting to ceiling r-31 °(5 ') Model G4/G5 Cover Plate -' I- 3-5/16" (84 mm) Dia. Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure 1 Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20x20 34 20 (6.1 x6.1) (128.7) (1.4) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 6 of 8 January 2020 www.reIiablesprinkler.com Cover Plate Finishes(') Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(') Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Mm. to Mm. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling1 Ceiling Rating inch (mm) inch (mm) RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL G5 (84) (67) (13) (38t051) (13t025) (57°C) RFC43, 135°F2 RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 165°F3 RFC49LL (74°C) 135°F2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C) RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (381C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January 2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Maintenance Guarantee Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC3O, RFC3OLL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC or G5 Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 Page 8 of 8 January 2020 www.reIiablesprinkler.com Bulletin 135 October 2019 Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model FiRes Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The FiRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D, The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed L Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Residential Sprinkler Summary ___________ Sprinkler Sprinkler Identification Orientation K-Factor gpm/psP12 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (lpm/bar119 NPTorlSO7-1 ftxft(mxm) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x 16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20x20(6.1 x6.1) F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or 14 x 14(4.3 x 4.3)Recessed F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com 2-1/4" (57mm) DIA. 1-15/16" (49mm) DIA. Face of fitting to finished ceiling 1/2'(l3mm) +1- 1/4" (6mm) Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2' NPTor lS07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F(68°C) 175°F (79°C) Material Specifications / Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy RI Recessed* Sealing Assembly: Nickel Alloy with PTFE °" Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2_(Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions Threads Wrench Flat Dom Sealing Assembly 2-1/4" (liZ...TTJ') Glass Bulb (57mm\ Load Screw Deflector T], 1/4" (32mm) Components Dimensions 1-3/4" (44mm) +1- 1/4(6mm) 2-7/8" (72mm) DIA. F2 & FV Recessed Escutcheon Installation Model F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems" Maximum Coverage Area Flow gpm (I/mm) ft. x ft.(m x m) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 X 14(4.3 x 4.3) 10(38) 11.0(0.76) 15 x 15(4.6 x 4.6) 12(45) 16.0(1.1) 16x 16 (4.9x4.9) 13(49) 18.8(l.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 2of 15 October 2019 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or 1507-1R1/2 Nominal K-Factor: 4.9 (71 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass-bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Wrenches Model W2 Model GFR2_(Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res4.9 Residential Pendent Sprinkler Components and Installation Dimensions sIuiiW 2-1/4" (57mm) 2-1/4" (57mm) hT- DIA. -Th Face of fittina DIA. Face of tittinn to finished 1-15/16" to finished ceiling (49mm) DIA. ceiling 5/8" (16mm) 1/2"(l3mm) i-/- 3/8" (9mm) +/- 1/4(6mm) (8" (41 mm) +/- 3/8" (9mm) w' 1/4" (6mm) ' I 1-3/4" (44mm) +1- 2-7/8" (72mm. L F2 & FV Recessed Escutcheon Installation Dimensions Fl Recessed Escutcheon Installation Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria 111i Minimum Flow and Residual Pressure in Wet Pipe Systems111 Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20x20(6.1x6.1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17 (64) 12.0 (0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20 x 20(6.1 x 6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3of 15 October 2019 . www.reliablesprinkler.com Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2" NPT or 1S07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons Fl Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) ('cTT * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4' (57mm) . 2-1/4" (57mm) DIA. -r Face of fitting DIA. -r Face of fitting 1 15/16 to finished ceiling 115/160 1 to finished 4(4 iD "lmA (49mm) IA. ceiling 5/8" (16mm) 1/2"(l3mm) 3/8" (9mm) +/- 1/4(6mm) 1-5/8' (41mm) +1 1 3/4 (44mm) 2-1/4" (57) (6mm) (32mm) L2718 (72mm) DlA. -3/8" (9mm) -2-8n72mm - Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems1' Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16x 16(4.9x4.9) 16(61) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 4 of 15 October 2019 . www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Threads: 3/4" NPT or IS07-1R3/4 Temperature Ratings Nominal K-Factor: 7.6 (109 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°c) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4° (57mm) DIA. 1-15/16" (49mm) DIA: Face of fitting to finished ceiling 5/8° (16mm) +1- 3/8°(9mm) 1-5/8"(41 mm) +/- 3/8° (9mm) 2-1/4' (57mm) DIA. 1-15/16" (49mm) DIA. Face of fitting to finished ceiling 1/2" (13mm) +1- 1/4" (6mm) 1-3/4° (44mm) +1- 1/4° (6mm) ro3s 2-1/4° (57) 1-5/8" (44mm) Dimensions 2-7/8 (72mm) DIA. 2-7/8" (72mm) DIA. Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model Fl Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems() Maximum Coverage Area121 Flow Pressure Deflector to ft. x ft. (m x m) gpm (I/mm) psi (bar) Ceiling Distance 18 x 18 (5.5 x 5.5) 21(80) 7.6 (0.52) 1 t 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 5 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or 1S07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and COP cover plates are not listed for use in positively pressurized ceiling plenums. Model Fl Res3O CCP and FP Recessed Pendent Sprinkler Installation Dimensions ')IQ" ' IOO ace of fitting to finished ceiling -1/4' (32mm) /- 1/4" (6mm) 15/16 (24mm) Face of fitting to finished ceiling 1-1/4' (32mm) +1- 1/4" (6mm) - 1(25mm) +1- 1/4" (6mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model FlRes30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage AreaM ft. x ft. (m x m) Flow I gpm (I/mm) I Pressure I psi (bar) I Deflector to Ceiling Distance 12 X 12 (3.7 X 3.7) 8(30) 7.0(0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14(4.3 x 4.3) 11(38) 13.4(0.92) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 6of15 October 2019 www.reliablesprinkler.com ,)_ciclu I7n,,,.1 CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2 NPT or 1S07-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8 (67mm) DIA. 2-5/16° (59mm)DIA. ace of fitting to finished ceiling -1/4" (32mm) _________ /- 1/4°(6mm) I I Face of fitting to finished ceiling I 1-1/4°(32mm) 1/4° (6mm) ,,,,,,, I (24mm) +/-1/4°(6rnrn) L3-3/16" (78mm) DIA. . FPRecessedEscutcheonInstallation Model F1Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems111 Maximum Coverage Area() ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 14x14(4.3x4.3) 13(49) 7.0(0.48) 1/2 to inch (13 to 25 mm) 16.7(1.15) 16 X 16(4.9 X 4.9) 14(53) 8.2(0.57) 18 x 18 (5.5 x 5.5) 18(68) 13.5(0.93) 20 x 20 (6.1 x 6.1) 20(76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 7 of 15 October 2019 www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPTor lS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8k (67mm) 2-5/8" (67mm) I DIA. 1 I I DIA. 1 I 2-5/16" (59mm)DIA. ace of fitting ceiling to finished I I I I Face of fitting to finished ceiling I r-1 1/4(32mm) 1/4 (32mm) kl -1/4(6mm) 1/4(6mm) 24mm) +/-1/4(6mrn) L3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst Maximum Coverage Area() ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16x 16(4.9x4.9) 16(61) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20(6.1 x 6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 8 of 15 October 2019 www.reliablesprinkler.com ,-)_c/p" CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4' NPT or 1S07-1 133/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)° FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8' (67mm) DIA. 2-5/16" (59mm)DIA. ace of fitting to finished ceiling -1/4(32mm) I- 1/4" (6mm) I I ____________________________________ 1 I Face of fitting to finished ceiling 1-1/4(32mm) 1/4(6mm) I ______ +/-1/4(6rnm) L3-3/18" (78mm) DIA. - FP Recessed Escutcheon Installation Model F1Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Area Flow Pressure Deflector to Ceiling Distance ft.x ft. (mxm) gpm(I/mm) psi(bar) 16 x 16 (4.9 x 4.9) 21(80) 7.6(0.52) 1/2 to 1 inch (13 to 25 mm) 18x18(5.5x5.5) 22(83) 8.4(0.58) 20 x 20 (6.1 x 6. 1) 25(95) 10.8(0.75) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 9 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2' NPTor lS07-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model Fl Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall ic,a" (A1,,,, '•, '-• .......F 3/8" (10mm) +1- 1/4" (6mm) +1- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) - -i DIA. Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to 150 mm)or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations (8mm) Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems111 Maximum Coverage Area' ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 7 12 x 12(3.7 x 3.7) 12(45) 7.5 (0.52) (l00 : 1 50 mm) 18.7(1.29) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.70) 15 x 15(4.6 x 4.6) 15(57) 11.6(0.80) 16 x 16(4.9 x 4.9) 16(61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20(4.9 x 6.1) 23(87) 27.4(1.89) 18 x 18 (5.5 x 5.5) 19(72) 12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7) 6 to 12 inches (150t0300 mm) 27.4(1.89) 14 x 14(4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) 16 x 16(4.9 x 4.9) 17(64) 15.0 (1.03) 16 x 18(4.9 x 5.5) 20(76) 20.7(1.43) 16 x 20(4.9 x 6.1) 23 (87) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 10 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2' NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F(68°C) 1750F(790C)(1) Cover Plates SWC SWC Conical Concealed Plate(') SWC-2 (Slotted) Conical Concealed Plate (3) Sprinkler Wrenches Model GFR2 SWC-2 Note: 11 Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. 21135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers 3 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions V (25mm) V (25mm) +1- 1/4" (6mm) +1- 1/4 (6mm) Face of fitting to finished wall 2-7/16'(62mm)----- - 2-5/8" Top of Deflector Down 5/16 (67mm) (58mm) - - - :- from ceiling to be Either (84mm) DIA. DIA. 2 150mm) or 6t0 12 DlA. (150mm to 300mm) 18mm) -------t06"(100mmt0 Based on Hydraulic Calculations N—(41mm) 15/8!. Dimensions SWC & SWC-2 Concealed Cover Plate Installation Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems011 Maximum Coverage Area() ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance psi (bar) Flow gpm (I/mm) Pressure psi (bar) Flow gpm (I/mm) Pressure 12 x 12(3.7 x 3.7) 13(49) 8.7 (0.60) 14(53) 10.2 (0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.7) 14(53) 10.2 (0.7) 15x 15(4.6x4.6) 16(61) 13.2 (0.91) -- 4to6 inches (100 to 150 mm) 16 x 16(4.9 x 4.9) 17(64) 15.0 (1.03) -- -- 16x 18(5.5 x5.5) 19(72) 18.7(l.31) -- -- 16 x 20 (4.9 x 6.1) 23 (87) 27.4(l.89) - - - - 12x 12(3.7x3.7) 14(53) 10.2 (0.7) -- -- 14x 14(4.3x4.3) 15(57) 11.7 (0.81) -- -- 6 to 12 inches (150 to 300 mm) 15x 15(4.6x4.6) 17(64) 15.0 (1.03) -- -- 16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16x 18(4.9x5.5) 20(76) 20.7(l.43) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 11 of 15 October 2019 RMO www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or 1507-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model Fl Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions _IuIi Face of fitting to finished wall 1-5/8" (41mm) 3/8(10mm) +/- 1/4(6mm) +1- 1/4" (6mm) 2-7/16"(62mm) 2-1/4° 1-1/16° 5/16 j (8mm) (57mm) DIA. (49mm) DIA. Top of Deflector Down from Ceiling to be Either 4 to 6" (100 to 150 mm) or6to 12" (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & P/ Recessed Escutcheon Installation Model F1Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems1' Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 16(61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 25.0(1.72) 14 x 14(4.3 x 4.3) 18 (68) 9.7 (0.66) 15 X 15(4.6 X 4.6) 19(72) 10.7 (0.74) 16x 16(4.9x4.9) 21 (80) 13.2 (0.91) 16x 18(5.5x5.5) 25(95) 18.6(1.28) 16 x 20 (4.9 x 6.1) 29(110) 12 x 12(3.7 x 3.7) 22(83) 14.4(l.0) 6 to 12 inches (150t030mm) 28.6(l.97) 14x 14(4.3x4.3) 22(83) 14.4(l.0) 15 x 15 (4.6 x 4.6) 24(91) — 17.1 (1.18) 16x 16(4.9x4.9) 26(98) 20.1 (1.39) 16 x 18(4.9x 5.5) 31 (117) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 12of15 October 2019 RONNOW44 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2' NPT or 1507-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8 (48mm) 3/8(10mm) +1- 1/4" (6mm) +1- 1/4" (6mm) -2-7/8 (73mm) - 6J (8mm) 2-1/4" 1-15/16' 1 Top of Deflector Down From (57mm) (49mm) Ceiling to be Either 4' to 6" DIA. DIA. (100 to 150 mm) or&'to 12' (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 &FV RecessedEscutcheonInstallation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) ft.x ft. (mxm) Flow gpm(I/mm) Pressure psi(bar) Deflector to CeilingDistance 18 x 20 (5.5 x 6. 1) 30(114) 26.8(1.85) 4 to 6 inches (100 to 150 mm) 52.4(3.63) 20 x 20 (6.1 x 6. 1) 30(114) 26.8(1.85) 16x22(4.9x6.7) 33(125) 32.4(2.23) 16x24(4.9x7.3) 38(144) 42.9(2.96) 14x26(4.3x7.9) 42(160) 18 x 20 (5.5 x 6. 1) 35(133) 36.4(2.51) 6 to 12 inches (150 to 300 mm) 62.9(4.34) 16 X 22(4.9x6.7) 38(144) 42.9(2.96) 16 x 24 (4.9 x 7.3) 42(160) 52.4(3.61) 14 x 26 (4.3 x 7.9) 46(174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 13 of 15 October 2019 www.reliablesprinkler.com Finishes Flelrao Standard Finishes Special Application Finishes Sprinkler'" Fl, F2. FV FP3, CCP, SWC (Conical) Sprinkler (1) Fl, F2. FV FPM, CCP, SWC (Conical) Escutcheons Cover Plates (l) Escutcheons Cover Plates (1) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester (2) Polyester Polyester (2) Polyester -- -- -- Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel -- -- -- PTFE (2) -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all Fl Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model GFR2 Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and lS07-1R1/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and lS07-1R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model W2 Bulletin 135 Page 14 of 15 October 2019 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or 1507-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) Bulletin 135 135 Page 15 of 15 October 2019 www.reliablesprinkler.com