HomeMy WebLinkAbout660 CARLSBAD VILLAGE DR; ; FPC2019-0154; PermitIJE1 i IJi1 Ji city of Carlsbad Alpl~' ~)~ Print Date: 04/12/2022 Permit No: FPC2019-0154 Job Address: 660 CARLSBAD VILLAGE DR, CARLSBAD, CA 92008-2305 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2033042600 Track #: Applied: 07/08/2019 Valuation: $359,131.28 Lot #: Issued: 07/15/2019 Occupancy Group: Project #: Finaled Close Out: 10/07/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: COLD BEERS AND CHEESEBURGERS -INSTALL NEW SPRINKLERS (46 HEADS) Applicant: FPContractor: INNOVATIVE FIRE PROTECTION INNOVATIVE FIRE PROTECTION INC DONALD SCHROEDER 8779 COTTONWOOD AVE, # STE 101 8779 COTTONWOOD AVE, # 101 SANTEE, CA 92071-4457 SANTEE, CA 92071-4457 (619) 593-8200 (619) 593-8200 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SPRINKLER MONITORING SYSTEM SUBMITTAL COLD BEERS & CHEESEBURGERS 660 CARLSBAD VILLAGE DRIVE CARLSBAD, CA 92008 S 5 FUEGO ENGINEERING & DESIGN INC P.O. BOX 212731 CHULA VISTA CA, 91921 CELL: (619) 610-8637 OFFICE: (619)796-3360 PREPARED FOR: FIVE ALARM SECURITY 2794 LOKER AVE W., SUITE 108 CARLSBAD, CA 92010 PHONE: 760-535-5205 PROJECT: COLD BEERS & CHEESEBURGERS 660 CARLSBAD VILLAGE DRIVE CARLSBAD, CA 92008 Model Number Description CSFM# 411UDAC FIRE LITE FIRE CONTROL PANEL 7300-0075:0174 S SLE-LTEV-CFB-PS NAPCO CELLULAR FIRE COMMUNICATOR 2W-B SYSTEM SENSOR CONVENTIONAL SMOKE DET S5U00672 FIRE DOCUMENT BOX ACE-li NP-7-12 BATTERY 12VDC, 7 AMP 7300-0992:0144 7272-1653:0152 7300-0553:0110 N/A S S FUEGO ENGINEERING & DESIGN INC P.O. BOX 212731 CHULA VISTA CA, 91921 CELL: (619) 610-8637 OFFICE: (619)796-3360 PREPARED FOR: FIVE ALARM SECURITY 2794 LOKER AVE W., SUITE 108 CARLSBAD, CA 92010 PHONE :760-535-5205 November 18, 1999 DF-51852 A3-0501 411 UDAC SJaFirelffe arms Fire Alarm Communicator S www.firelite.com GENERAL The Fire-Watch 411UDAC from Fire•Lite is a compact, multifaceted, stand-alone or slave Fire Alarm Communica- tor designed for a variety of fire and non-fire applications. It provides four channels (inputs) that accept waterflow de- vices, two- and four-wire smoke detectors, pull stations, and other normally-open contact devices. The 411UDAC is a cost-effective solution for applications that require an existing (or new) Fire Alarm Control or Security Panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. Due to its extremely flexible programming options, the 411UDAC is also ideal for use as a stand-alone unit to monitor: sprinkler systems for waterflow and supervisory conditions; processes (i.e., water level, gas detection, loss of air flow); and normally- open contact devices, With fifteen selectable transmis- sion formats, including Ademco Contact ID, compatibility with virtually all Digital Alarm Communicator Receivers (DACR) is ensured. Programming can be accomplished on-site with a hand-held programmer (PRO-411), or re- motely utilizing an optional PK-411UD Windows®-based remote upload/download software package. The PK-411 UD upload/download software also permits system interroga- tion and revision from a remote site. FEATURES Four supervised monitoring channels (inputs): three fixed Style B (Class B) and one Style A (Class A) or Style B (Class B). Inputs may be individually programmed for stand- alone applications, or when monitoring a host con- trol panel, for: V Two- and four-wire smoke detectors (Inputs 1 and 3). V Pull station. V Normally-Open contacts. V Host panel trouble (slave mode). V Supervisory. V Supervisory (autoresettable). V Waterflow (silenceable). V Waterfiow (non-silenceable). V Process monitoring. V Process monitoring (autoresettable). One Style V (Class B) Notification Appliance (bell) Cir- cuit (NAC). 1.0 Amp notification appliance power. Coded (temporal) notification appliance (bell, signal) cir- cuit. 12 VDC operation. Capable of 60 hours of standby. Section: Control/Communicators M EA California 7300-0075:174 Vol. VI S624 -. 411UDAC Seven individual LEDs; six visible through door: V AC Power. V System Trouble. V System Alarm. V Supervisory. V Communication Fail. V Battery Trouble. V Earth Fault (not visible with door closed). Dual telephone lines: V Dual telephone line voltage detect. V Alternating phone lines for 24-hour test mes- sages (programmable). Industry-first, UL recognized, dialer runaway" pre- vention feature. C Windows® is a registered trademark of Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our product informa- tion up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.IS09001 All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, _____________________ One Fire-Lite Place, Northford, Connecticut 06472. dl I Phone: (800) 627-3473 Toll Free FAX: (877) 699-4105 FAX Back:(888) 388-3299 ENGINEERING & MANUFACTURING DF-51 852 - Page 1 of 4 New long-distance Carrier Access Code (CAC) compli- ant, accepting 20-digit central station and service termi- nal telephone numbers. Industry-first, user-selectable restoral methods. Fully programmable transmittal codes for fire and non- fire (e.g., process monitoring) applications. Capable of transmitting the following DACT Informa- tion, in addition to vital system status of the host control panel: V DACT troubles. V Telephone line 1 and 2 voltage fault. V Primary or Secondary Central Station communica- tion fault. V System off-normal. V 24-hour normal test. V 24-hour abnormal test. Includes 15 popular communication formats, including the widely used Ademco Contact ID format, ensuring compatibility with virtually all DACRs. Local piezo sounder with separate and distinct sounds for various conditions. Acknowledge/System Silence and Reset switches. Alarm verification. Signal silence inhibit. Autosilence. Trouble reminder (with 24-hour resound). Real-time clock. OPTIONAL: two Form-C relays (411 RK), fully pro- grammable to activate for the following conditions: V Fire alarm. V Process monitoring (autoresettable). V Host control panel trouble. V Total communication trouble. V Fire supervisory (latching). V Fire supervisory (autoresettable). V DACT trouble (factory default for relay). V Process monitoring. Optional PK-411UD Remote Upload/Download Kit. Optional DP-2 Dress Panel (required for Canadian ap- plications). HOUSING The cabinet is red and measures 14.5" (36.83 cm) high x 12.5' (31.75 cm) wide and 2.875' (7.303 cm) deep. It pro- vides space for up to two 7 A.H. batteries (order batteries separately). An optional dress panel, DP-2 (required for Canadian installations), which mounts inside the cabinet, is available. The dress panel restricts access to the sys- tem wiring but allows access to the membrane switch panel. PHONE LINE CONNECTIONS Two modular phone connections are provided on the 411UDAC, accessible by simply opening the door. They provide connections for two separate telephone lines us- ing standard RJ31X or RJ38X jacks. Both telephone lines are constantly supervised for proper voltage and current. If one phone line goes into fault, and the remaining is op- erational, a report is sent to the central or remote station via the operable phone line. COMMUNICATION FORMATS 0: 4+1 Ademco Express Standard, DTMF, 1400/2300 ACK. 4+2 Ademco Express Standard, DTMF, 1400/2300 ACK. 3+1 Standard 1800 Hz Carrier, 2300 Hz ACK. 3+1 Expanded 1800 Hz Carrier, 2300 Hz ACK. 3+1 Standard 1900 Hz Carrier, 1400 Hz ACK. 3+1 Expanded 1900 Hz Carrier, 1400 Hz ACK. 4+1 Standard 1800 Hz Carrier, 2300 Hz ACK. 4+1 Expanded 1800 Hz Carrier, 2300 Hz ACK. 4+1 Standard 1900 Hz Carrier, 1400 Hz ACK. 4+1 Expanded 1900 Hz Carrier, 1400 Hz ACK. 4+2 Standard 1800 Hz Carrier, 2300 Hz ACK. 4+2 Expanded 1800 Hz Carrier, 2300 Hz ACK. 4+2 Standard 1900 Hz Carrier, 1400 Hz ACK. 4+2 Expanded 1900 Hz Carrier, 1400 Hz ACK. F: Contact ID, DTMF, 1400/2300 ACK. F: Future Use. SPECIFICATIONS This digital communicator/transmitter has been de- signed to comply with standards set forth by the fol- lowing regulatory agencies: Underwriters Laboratories, Inc. NFPA 72 National Fire Alarm Code. CAN/ULC: S527 - M87 Standard for Control Units for Fire Alarm Systems. FCC Registration: OAAUSA-25431 -AL-E. Ringer Equivalence: 0.5 B. For Canadian Applications: IC Certificate Number: 2132 9028 A. Ringer Equivalence Number (REN): 0.2. PROGRAMMING: An optional digital programming unit with a keypad, model PRO-411, is available for program- ming the 411 UDAC. It is also used for troubleshooting and accessing the various modes of operation. Off-site pro- gramming can be accomplished with the optional PK-411UD kit (includes 3.5" disks and manual). The PK-411UD enables a user to program the 411UDAC off- site via the public switched telephone network using any personal computer with Windows 3.1 or higher or Windows 95 and a 1200-baud Hayes® compatible modem. GENERAL SPECIFICATIONS: AC Power (TB3): 120 VAC, 60 Hz, 0.3 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery (Lead-Acid Only) (J3): Maximum charging cir- cuit: normal flat charge 13.7 V @ 0.6 amps. Maximum charger capacity: 14 A.H. battery. Channels/Inputs (TB2 Terminals 1 through 10): Programmable Channels 1 through 4. Power-limited circuitry. Fully supervised (monitored for opens, shorts, and earth faults). Normal operating voltage: 12.0 VDC (ripple 100 niV maximum). End-of-line resistor: 2.2K ohms, 1/2 watt (part # 27070, UL listed). [I S S Page 2 of 4 - DF-51 852 Operation for each channel: • Channel/Input 1, Style B (Class B) two-wire smoke de- tector input and Channel/Input 3, Style B (Class B) or Style D (Class A) two-wire smoke detector or waterflow input. Channel/Input 2 and Channel/Input 4 Style B (Class B) contact closure input. Refer to Device Compatibility Document for listed com- patible devices. Notification Appliance Circuit (T1134 Terminals 1[+] and 2[—]): Style V (Class B) circuit. Power-limited and supervised (monitored for opens, shorts, and earth fault). Operating voltage nominal 13.8 VDC. Current for all external devices: 1.0 amp. End-of-line resistor: 2.2K ohms, 1/2 watt (P/N 27070). Refer to Device Compatibility Document for listed com- patible devices. Two Optional Form-C Relays (T1131 Terminals 1 through 6): Operating voltage: nominal 12 VDC. Contact rating: 2.0 amps @ 30 VDC (resistive), or 0.5 amps @ 30 VAC. 12 VDC Resettable Power (TB4 Terminals 3[+] and 4[—]): Operating voltage: nominal 12 volts. Up to 200 mA available to power four-wire smoke detec- tors. Secondary Power Source (Batteries): One 12-volt bat- tery can provide power for up to 7 A.H. applications. Two 12-volt, 7 A.H. batteries (in parallel) can provide power for up to 14 A.H. applications (60 hour standby). The battery charger is current-limited and capable of recharging sealed lead-acid-type batteries. The charger shuts off when the system is in alarm. Refer to the battery calculations table in the 411UDAC manual to determine the correct battery rating. TRANSFORMER ASSEMBLY: One transformer is shipped in the same carton as the cabinet and main circuit board but not mounted in the cabinet. The transformer should be installed before the cabinet is mounted to the wall. AUXILIARY RELAY: Two optional Form-C relays (411 RK) are available for installation on the 411 UDAC main circuit board. The relays are programmable for activation on fire alarm, host panel trouble, fire supervisory, process monitoring, total communications failure, and DACT trouble. R!ay contact rating: 2.0 amps @ 30 VDC (resistive); or 0.5 amps @ 30 VAC (resistive). PRODUCT LINE INFORMATION Model Description 411UDAC Four-channel, dual-line, stand-alone or slave Fire Alarm Communicator. Includes housing, operating and programming instructions. Use PRO-411 (below) hand-held DACT program- merfor local programming; or PK-41 1 UD (be- low) Windows-based programming software for remote programming and real-time diag- nostics. DP-2 Dead-front dress panel, required for Cana- dian applications. PRO-411 Optional hand-held DACT programmer which can be used to troubleshoot and program the 411UDAC, as well as access the various modes of operation. PK-411 UD Remote upload/download, Windows 95 com- patible, programming software kit (3.5' disk and PK-411UD Program Manual). The PK- 411UD enables a user to program the 411 UDAC off-site via the public switched tele- phone network using any personal computer with Windows 3.1 or greater or Windows 95 and a 1200-baud Hayes®-compatible mo- dem. 411 R Optional dry auxiliary Form-C relays, with contacts rated for 2.0 amps @ 30 VDC (re- sistive) or 0.5 amps © 30 VAC (resistive). Optional use requires two relays. MCBL-7 DACT phone cord, seven feet long (two re- quired). PS-11 270 Battery, 12-volt, 7.0 AH (one required for 24- hour systems; two [wired in parallel] required for 60-hour systems). See page 4 for COMPATIBLE UL-LISTED RECEIVERS S Power-limited and supervised circuitry. Recommended maximum standby current: 50 mA. NOTE: 1) For power supply and battery calculations, refer to S the 41IUDAC manual. OPERATING POWER: Primary Power Source (AC): AC power connections are made inside the 411 UDAC cabi- net. The primary power source is 120 VAC, 60 Hz, 0.3 amps. DF-51 852 - Page 3 of 4 COMPATIBLE UL-LISTED RECEIVERS The chart below shows UL-listed receivers compatible with the 411 UDAC: Format # (Adresses 16 & 42) Ademco 5(i) Silent Knight m CS4000 CP220FB Osborne el FBI Hoff man Radionics 6000/6500 Sescoa 3000R SurGuard MLR-2 0 4+1 Ademco Express V V V 1 4+2 Ademco Express V V 4 (8) V V 2 3+1/Standard/1800/2300 V V (2) V V (4) V V(56) V V 3 3+1 /Expand ed/1800/2300 V V (2) V V (4) V V V 4 3+1/Standard/1900/1400 V V (2) V (4) V V V 5 3+1/Expanded/1900/1400 V V (2) V (4) V V V 6 4+1/Standard/1800/2300 V V (2) V V (4) V V (5) V 7 4+1/Expanded/1800/2300 V V (2) V (4) V V V 8 4+1/Standard/i 900/1400 V V (2) V (4) V V V 9 4+1/Expanded/1900/1400 V V (2) V (4) V V V A 4+2/Standard/i 800/2300 V V (2) V V (4) V V (5) V V B 4+2/Expanded/i 800/2300 V V (2) V (4) V V V C 4+2/Standard/1900/1400 V V (2) V (4) V V V D 4+2/Expanded/1900/1400 V V (2) V (4) V V V E Ademco Contact ID V V V V 51735.IbI KEY: With 685-8 Line Card with Rev 4.4d software. With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-1 1 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. Model 6500 with Rev 600 software. Model 6000 with Rev 204 software. With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. Model 2 only. Version 1.62 software. Page 4014 - DF-51852 S S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0174 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettl-1oneywelI.com DESIGN: Models UDACTF, 411, 411-UD and 41 1UDAC digital alarm communicator transmitter and Model ABS-8RF enclosure (for use with Model UDACTF only). The UDACTF, 411, 411 UD and 411 UDAC units are intended to provide central station service over a standard two-wired telephone switching network. The UDACTF is for use with listee's separately listed fire alarm control units. The 411, 411 UDAC and 411-UD are for use with any UL and CSFM listed control units. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: UDACTF: 21.2 - 28.2 VDC 411, 411-UD: 11.7- 12.4 VDC (nominal) or 21.3-24.0 VDC (nominal) 411 UDAC: 120 VAC, 12 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as digital alarm communicator transmitters for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Photoelectric Smoke Detectors System Sensor j3" series smoke detectors represent significant advancement in conventional detection. The /3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built- n remote maintenance signaling Drill compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® zE -. MEA MSFM LISTED APPROVED approved approved S911 3011446 7272-1653:152 290-01-b 2093 3180932 Installation ease.The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base.The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, j3 heads plug into the base with a simple Stop-Drop 'N Lock" action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the il line to minimize nuisance alarms, 2-wire P detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the j3 protocol, the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. C (j) Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4VVT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pie-wiring of the base and the head shall be a plug-in type.The detector shal have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-8: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) xed Freeze Trouble 2WT-B and 4VVT-8 only: 41°F (5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Rod LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 2W1-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WV-B Yes 4-wire 20mA@ 12V,23 mA@24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal /replacement too SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16,76 cm) diameter STEM Syv- 5e-r, 0 3825 Ohio Avenue. St. Charles, IL 60174 02 09 ft, Phone: 800-SENSOR2. Fax: 630-377-6495 8/28/2018 System Sensor 2-wire Compatibility for 411 UDAC by Fire-Lite C 2-wire Compa8b14 for Monufcturer: FireLite Model: 4IIUDAC I rr' 4l j I ; I -4 _l 2V51(T) ;U1iUL, ;N/A 2WT-B N/A N/A BD 2,2K/f 20 N/A B, D 2 2K/N/A A D2 N/A 20 N/A B, D 2.2K/N/A A S I Jtj)s://www. honeywellf ire.com/sys/2wirecomp/2wirprnt.php?panel=411 UDAC&co=Fire-Lite 1/1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-8 and 2WT-B are 2-wire and model 4W-B and 4\NT-B are 4-wire detectors. Models 2W1-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 -35 VDC INSTALLATION: In accordance with listee's printed installation instwctions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct requirements or installation criteria. Refer to listee's data sheet installation instructions and/or other S operational Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division StarLink TM SLE-LTE Commercial Series NAPCO I 333 BayviewAvenue AmitVille, Alarm Communicators For Sales and Repairs, (800) 64""5 vcwitycorn at INSTALLATION INSTRUCTIONS (Note: Technical Service is for security professionals only) Publicly waded on NASDAQ Symbol: NSSC ©NAPCO 2019 W12226DLF 6/19 INTRODUCTION The StarLink°" Commercial I Residential Fire and Burglary alarm capture radio communicators are fully supervised, \Jiieless digital two-way subscriber units supported by an (xtensive nationwide wireless network. All models are coilpatible with most 12VDC alarm control panels (always adhere to the documentation provided by the control panel manufacturer). Model SLE-LTEV-CFB and SLE-LTEA- CFB are compatible with most 12 or 24VDC control panels. All can function as a backup to existing telephone lines, or as sole path primary communicators. In backup mode, all units will automatically switch the communication channel from the telephone line to the network when tele- phone line trouble is detected. See W12140 for program- ming information. The SLE-LTE Series radios use data-capture technology 1!13t captures the alarm report from the control panel and trnsrnits the alarm signals to the SLE Control Center; the ulurrn sigials are then forwarded to ANY central station via Contact ID or 4/2 via DACT from the NOC or Sur-Gard System II, Sur-Gard System V, Bosch D6I00IPV6 or Bosch D6600 Receiver (with ITS-D6686 Ethernet Adapter) via TCP/IP using standard line security. The SLE Control STARLINK RADIO REPORTING PATH The diagram below shows the transmission path of a signal from the StarLink radio to the central station. Signal from a Control Panel. StarLink radio receives the signal transmission (Iron. the TIP an RING wires); sends RF signal through the network operator. Network Operator, part of the vendor system, a section of the cellular spectrum. SLE Control Center, receives and routes data. Central Station. rA StarLink _ Radio (2) (3) Con oI Panel (1) Network Operator (4) CENTRAL (5) UL Classified StarLink Network STATION Operations Center Center reports a trouble signal in the event that the network does not receive the expected supervision signal from the wireless communicator. For Commercial Burglary installations, under the armed condition, any loss of communication must be treated as a Burglary Alarm at the Central Station. The following Verizon (LTEV) and AT&T (LTEA) models are available: SLE-LTEV-CFB-PS & SLE-LTEA-CFB-PS: Commercial I Residential Fire and Burglary Radio in red metal housing with SLE-ULPS-R power supply and 16.5V I 20VA trans- former mounted inside housing SLE-LTEV-CB-TF & SLE-LTEA-CB-TF: Commercial I Residential Burglary and Residential Fire Radio in white metal housing with SLE-ULPS-R power supply and TRF1 2/T123 plug-in 16.5V I 20VA transformer SLE-LTEV-CFB & SLE-LTEA-CFB: Commercial I Resi- dential Fire and Burglary in red metal housing. Powered directly from control panel (no power supply, no trans- former, rated 12124VDC input) SLE-LTEV-CB & SLE-LTEA-CB: Commercial I Residen- tial Burglary and Residential Fire Radio in white metal housing. Powered directly from control panel (no power supply, no transformer) The following features are included with models that include a SLE-ULPS-R power supply: Power limited output to the StarLink radio PC board 12V input terminals Battery connection red and black flying leads Monitored battery charging and Active battery test circuits StarLink radio trouble input (from StarLink radio PC board PGMI terminal to detect StarLink radio trouble) Requires a sealed lead acid min 4AH I max 7AH battery for minimum 24-hour standby time (max charge current 200mA). Trouble relay output (C, N/O and N/C terminals) to wire to a panel zone dedicated to 'LTE Trouble" (dry con- tacts). Remove jumper "J2" to isolate common from ground Green AC ON LED visible from the exterior housing Yellow TROUBLE LED on PC board. Flashes signify: AGENCY LISTINGS UL 864 Standard For Control Units and Accessories For UL Fire Alarm Systems, 10th Edition UL 1610 Standard For Central-Station Burglar-1AJarm Units UL 985 Standard For Household Fire Warning System Units UL 1023 Standard For Household Burglar-Alarm System Units LTEV models are Verizon® Network Certified One flash: AC fail I brownout (2 hour delay) Two flashes: Low battery Three flashes: Charging circuit trouble Four flashes: StarLink radio trouble The housing-mounted transformer (when provided) is mounted inside its own housing compartment with a re- placeable UL Listed .5A fast blow primary fuse. 120VAC connections are to be made by a licensed electrician using suitable connectors, in accordance with N.E.C. and local code requirements. ADDITIONAL COMPONENTS In addition to the models listed above, the following sub- assemblies are available: SLE-ULPS-R - Power Supply. Required for installations where the control panel cannot provide the 71mA of Auxiliary power required to operate the StarLink radio. Uses a standard 4AH / 12V minimum (7AH maximum) rechargeable battery to provide radio standby power. Requires connection to either the model NAPCO TRF1 21T123 (16.5V I 20VA) external plug-in transformer or the chassis-mounted 16.5VAC I 20VA transformer affixed inside the housing (see wiring diagrams further in this manual). Note: For models without the SLE-ULPS- R, connect the radio terminals I and 2 to the control panel Aux Power terminals (observing polarity). SLE-DLCBL - Download Cable, 6 feet SLE-ANTEXT30 - Extended antenna with 30 feet of cable SLE-ANTEXT50 - Extended antenna with 50 feet of cable SLE-ANTEXT75 - Extended antenna with 75 feet of cable (Any suitable external cellular antenna is permitted by UL). Always follow the manufacturer's installation in- structions. Note: Antennas are not Listed by UL. GEM-Tamperkit - Tamper switches and screws to protect metal housing (see page 18). SPECIFICATIONS The following specifications apply to all StarLink radio mod- els unless otherwise stated: Electrical Ratings for I20VAC, 60Hz For Models with Power Supply . Input Voltage: 120VAC nominal Input Current: 150mA maximum Maximum Charging Current: 200mA Electrical Ratings for +12V For Models without Power Supply* Input Voltage: 10-15VDC (power-limited output from Listed control panel). Note: Models SLE-LTEV-CFB and SLE-LTEA-CFB are rated 10-25VDC input. Input Current for SLE-LTEV-CB and SLE-LTEA- B: by = 90mA, 12-15V = 71mA, with peak RF transmis- sion current of 200mA. Input Current for SLE-LTEV-CFB and SLE-LTEA-CFB: 10V = 90mA, 12-25V = 71mA, with peak RF transmis- sion current of 200mA. Electrical Ratings for the IN I Burg/Fire Input: Input Voltage: 9-15VDC. Note: Models SLE-LTEV- CFB and SLE-LTEA-CFB are rated 9-25VDC input. Maximum Input Current: Up to 2mA from FACP NAC circuit Electrical Ratings for IN 2 and IN 3: Maximum Loop Voltage: 15VDC. Note: Models SLE- LTEV-CFB and SLE-LTEA-CFB are rated max 25VDC input. Maximum Loop Current: I .2mA End of Line Resistor (EOLR) Value: 10K (2 req'd) Electrical Ratings for 3 PGM Outputs: Open Collector Outputs: Maximum Voltage 3V when active; 15V maximum when not active. Note: Models SLE-LTEV-CFB and SLE-LTEA-CFB are rated max 25VDC output. Maximum PGM Sink Current: 50mA (up to 15\/DC), 25mA (15.1 VDC - 25VDC) Physical (Wx H x D) Metal Housing: 111/2 x 9V2 x 31/2" (29.2 x 24.1 x 8.9cm) Mounting: Metal housing includes two keyhole slots for wall mounting (see measurements on page 7) Environmental Operating Temperature: 0°C - 49°C (32°F - 120°F) Humidity: Maximum 93% Non-Condensing Indoor I dry location use only NOTICE TO AUTHORITIES HAVING JURISDICTION, USERS, INSTALLERS, DEALERS, AND OTHER AFFECTED PARTIES FIRE PROGRAMMING OPTION PERMITTED IN UL864? (YIN) AVAILABLE SETTINGS REQUIRED UL 864 SETTINGS Disabled (Jumper 1 installed). Also required for Commercial I Burgla- Unattended Remote Downloading No Enable! Disable ry installations. Note: See page 7 "Configuration Download! Firm- ware Updates" for jumper instructions. Unsupervised using conduit within 20 feet of FACP (default). If not IN2 and IN3 Unsupervised Yes Supervised I Unsupervised using conduit, install Jumpers 4 and 5 and EOL Resistors (see pages 3 and 4). 7 Day Supervision Radio to NOC No 200 seconds, 5 minutes, 60 minutes, 7 days 200 seconds 5 minutes 60 minutes Tor Commercial Fire installations, a UL Listed Fire Alarm regulated power supply or FACP regulated auxiliary output is required. StarLink' SLE-LTE Commercial Series Alarm Communicators-- Installation Instructions CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0992:0144 Page 1 of 2 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Napco333 BayviewAvene, Amityville, NY 11701 Contact: David Wagner (631) 842-9400 Fax (631) 842-2726 Email: dwagner@napcosecurity.com DESIGN: Models SLE3I4G-CB, SLE3/4G-CB-TF, SLE3I4G-CFB, SLE3/4G-CFB-PS, SLE-CDMA, SLE-CDMA-FIRE, SLE-GSM-3/4G, SLE-GSM-FIRE, SLECDMA-CB, SLECDMA-CB-TF, SLECDMA-CFB, SLECDMA-CFB-PS, SLE-LTEV-Fl RE, SLE-LTEV-81D, SLE-LTEV, SLE-LTEV-CFB-PS, SLE-LTEV-CB-TF, SLE-LTEV-CFB, SLE-LTEV-CB, SLE-LTEA-CFB, SLE-LTEA-CFB-PS and SLE-LTEA-FIRE Sole Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. Models SLECDMAI-CFB-PS, SLE3/4G1-CFB-PS, SLECDMAI-CB-TF, SLE3/4G1-CB-TF, SLECDMAI-CFB, SLE3/4G1-CFB, SLECDMAI-CB, SLE3/4G1-CB, SLE-GSMl-3/4G, SLE-CDMAI, SLE-GSM I-FIRE, SLE-CDMAI-FIRE, SLE-LTEVI-CFBPS, SLE-LTEVI-CFB, SLE-LTEVI-FIRE, *SLELTEAI..CFBPS *SLELTICFB and *SLELTEAI..FIRE. Dual Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 Vac - SLE3/4G-CB, SLE3/4G1-CB-TF, SLE3/4G-CFB-PS, SLE3/4G1-CFB-PS, SLECDMA-CFB-PS, SLECDMAl-CFB-PS, SLECDMA-CB-TF, SLECDMAI-CB-TF, SLE-LTEV-CFB-PS, SLE-LTEV-CB-TF, SLE-LTEVI-CFBPS, SLE-LTEA-CFB-PS, *SLELTE/\ICFBPS 10-15 Vdc- SLECDMAI-CB, SLE3/4G1-CB, SLE-GSMI-3/4G, SLE-CDMAI, SLE-LTEV, SLE-LTEV-8D, SLE-LTEV-CB 10-25 Vdc- SLECDMAI-CFB, SLE3/4Gl-CFB, SLE-GSMl-FIRE, SLE-CDMAI-FIRE, SLE-LTEV-Fl RE, SLE-LTEV-CFB, SLE-LTEVI-Fl RE, SLE-LTEA-CFB, SLE-LTEA-FIRE, *SLE..LTI..FIRE *SLELTEAlCFB, SLE-LTEVI-CFB 11-15 Vdc- SLE3/4G-CB, SLE-CDMA, SLE-GSM-3/4G, SLECDMA-CB 11-25 Vdc - SLE3/4G-CFB, SLECDMA-CFB, SLE-CDMA-FIRE, SLE-GSM-FIRE *Rev 09-23-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30,2020 Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division Listing No. 7300-0992:0144 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Rev 09-23-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 S Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division S S '. (. S - SIGNALING V LISTED Standard Features: 2 Key ring hooks to hold system keys * Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Leger d sheet for passwords and system information FIRE DOCUMENT BOX The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. L C REGTE RED COMPANY MEMBER Made In\U.S.A. 1 Space Age Electronics, Inc. 2013 ED3447 LT10505 Rev.c 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. 13 Property InfonrrAtIorr Minim arA Required DocantOntstlon (SIG-FUN) 1-113-111) Cortlflantlonn And Approvals OtanmOinra OcrA,! ervorvtAl m..vv,v rOte! 16.1 System voetatation Contractor n,o 000000 0. or 000050, et rr0 all tOCAr.t00000A 005flr0702 Eqvlpmsnt tntonrnetlnn 00000 , Sp&r,A, tekartrSloc. tot5000005fl00d )l 5. Btt.011723 won0500rarrt LTI0340 Rev I Legend sheet for storing system information including contacts, sign-off, maintenncc & test information, and alternate locatiors of additional records. ii Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00672 Fire Document Box RED SSU00673 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0447 LT1 0505 Rev.0 2/2 11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models 1C2-32, TC1-1 8, TCX/A 64 TCXID 128, ACE/A, AC2, ACE/D, IF-2, IFi IFX/A and IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13, *AcE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S Reliability is your Security Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation (except continuous inverted). Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. ':L e&ies Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. (Excluding continuous use inverted) Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Seccions Yuasa NP, NPC and NPH Batteries. Utilising the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. S Nominal Capacity (Ah) NP7.12 20hr to 1 .75vpc 3000 7 1 0h to 1.75vp 20'C 6.4 Stir to 1,70vpc 20C 5.9 lhrto 160vpc200C 4.2 Voltage 12 Energy Density (Wh.L 20hr) 91 Specific Energy Wh kg 20hr) 32 nt, Resistance (m.Ohms) 25 Maximum discharge (A) Short Circuit current (A) 40/75 210 Dimensions (mm) Length 151 65 Height overall 97.5 Weight (Kg) 2.65 Terminal A/D Layout 4 Terminal Torque Nm Conteol of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Layout Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Faston tab: 187 A Eastun tab: 230 B 180.004 .020 I 2 H 1 .250 6.35 . 013 7.90 185 4,70. . . . 098 2.50 71 0.3 050 1 50 020 0 '031 0,90 020 050 .004 0 10 .031 1 Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. OpeathigTe'+> 16 The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge — 15°C to 50°C Discharge — 20°C to 60°C Storage — 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS 75 25 15 (1 5 12 1602150111 MONTHS N 010 NP DISCHARGE CHARACTERISTICS CURVES AT 25°C (772F) FF10 1102 MS'CC.:.:cap>> y]++I1. BA 16061 EU IL-Fl 1025 C F) 115 5.5 0 5.5 5.0 9.0 12+> 4> 1.IN2 V 1(020+ 1>10, 0 SCOURGE GIL 4- y' L1m. • NP SERIES- NP742 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials CYCLIC RECHARGE REGIME 11l 0216 , S l2yC>1> 02 I'S IS 020 115 T.t 016..b2 ,I IS 02 160 14 13 0 0.05 . 0 TIll> FLOAT SERVICE LIFE NP RANGE 120 80 60 40 i5 LIFE GLOSS 1101 :+C 66 10 FLOAT CHARGE CHARACTERISTICS 02 20 + i . tt ' 0050FO 227 IJ 12/PC O>1000T VOLTAGE CHAI)63)III Cl) ('CE' 2 >10.0: .. (68'F . 1+52 --•---•-- .---++-- IV -- SIN 7 , AF510B+ 01006120,: FL 010 .1651022+ .016>1+ 0+05 CF 16 16000 2 101 0 0 - 0 2 +1 4 1, II CIIArFUI-SIS 111+10 (-OURS" TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TFSTI>2, C0500SSI,S 0 00>1560+ SUSIFFI0 >1102>1+12 '5>1 ovOr 2. RHO 5160.2,1.1_Ill >20',', 065051120 UC,.U0 >2> >2' 0 00620>51 05050 T S O (A' ) 0616010 TFI,0>2F112'AI'A ,'S(TCI,C 05 FTO7Y>F) .0 •"' 350012:1 H I NUMBERS SFCYCLES NP SERIES - NP742 INTELLIGENT BATTERY CHARGERS Manufactured to BS3456, 1EC335, UL 1236, EN60335, CE mark to EN5008-1 Featuees Micro processor controlled Short circuit protection Reverse polarity protection High temperature protection Soft start current control Fast constant current bulk charge 3 stage charging Cl-CV-float Constant voltage float/standby Proportional timing Flexibility, to match battery specification. Standard Range YCP03Al2 300mAl2v Y0P03A24 300mA24v YCP03A6 300mA6v YCP06Al2 600mAl2v YCP06A6 600mA6v YCP1.5Al2 1.5A 12v YCP1.5A24 1.5A 24v YCP1.5A6 1.5A 6v YCP1Al2 1Al2v YCP1A6 1A6v YCP2Al2 2A 12v YCP2A24 2A 24v YCP2A6 2A6v YCP3Al2 3Al2v YCP4\12 4Al2v YCP6Al2 6Al2v YCP8Al2 8Al2v YCP1OAl2 10Al2v YCP8A24 8A 24v RELATIONSHIP BETWEEN CHARGING VOLTAGE AND TEMPERATURE 25 0 14A 72 2A 14 32 00 10 86 12.1 122 11F) I AM10TTEP[11AfI.HE fl NPH DISCHARGE CHARACTERISTIC CURVES (11 FOR I2N FOR V 0011000 0011100 6.5 10 1A LU :: __ i ::ii CIA L Ii 01--o 0 1 2 34 5010 20 3040 60 23. 6 81 MINUTES HOURS DISCHAHGETME Standard NP Available in a wide range of sizes to suit general applications. NPH/NPW High performance batteries specially designed for applications requiring high rate discharge, supplying up to 50% (NPH), (NPW) more power (Watts) for short durations when compared to conventional NP models. NPC Specifically designed to suit the arduous requirements of cyclic applications allowing increased cycle life (at least double that of conventional types). (N PC Shortform refers) NPL Long Life Model also to BS6290pt4 (FR Options) Dedicated literature available on request. (NPL Shortform refers). Applications Yuasa NP batteries, having excellent deep discharge recovery characteristics coupled with long life on float standby, are ideal for numerous applications in both cyclic and standby modes. For advice on the use of NP batteries in your particular application please contact our Sales Office. Charging For Float Standby Applications Charged at 2.275 volts per cell continuous. The battery will seek its own current level and float fully charged. However, users should be aware that when charging from fully discharged,.the battery can draw an initial charge current of approximately 2cA. Care should therefore be taken to ensure that this initial charge current (if ungoverned) is within the output capability of the equipment. Final charge current at 2.275 volts per cell is typically between 0.0005cAto 0.004cA. Charging For Cyclic Applications See cyclic recharge regime graph. CAUTION - Do not Short Circuit - Do not charge in a sealed container - Service life and operational characteristics will be affected by temperature - AC Ripple reduces service life. 7/7 Yuasa Battery Sales (UK) Ltd 0 Unit 22 Rassau Industrial Estate "I Ebbw Vale, Gwent, NP23 5S0 Tel: 08708 500312 Fax: 08708 500317 U E-mail: enquiries@yuasa-sales.co.uk yr UASA Registered number 1548820 Cat. No. I NP7-12 February 07 E&O.E. Distributed by R I,a bil 0 Bulletin 034 Rev. D Model G5-80, Model G5-56, Model G5-42, Model G5-28 Quick Response Concealed Automatic Sprinkler C CD 0 0) CD UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment Features 1 Cover plate attachment (Plain or Perforated) with 3/4" (19mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1 Underwriters Laboratories Inc. and cULus - Quick Response G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies G5-42 - Light Hazard Occupancies G5-28 - Light Hazard Occupancies 2. Factory Mutual Research corp. (FM) - Standard Response (See Page 3) G5-56 & G5-28 only. See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention council (LPCB, UK) - Standard Response G5-56 - Light Hazard and Ordinary Hazard Occupancies VdS SchadenverhUtung GmbH - Standard Response EC-Certificate of Conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. Cut a 2 /8" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER! CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Plain or Perforated Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes 1 Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Max. Ambient Plate Temp. Ordinary 165°F/74°C 135°F/57°C 1001F/380C Intermediate I 212'F/1 00'C I 165°F174°C 150°F/66°C 2. N N \ \ N N N CEILING [79.05mm] MAX. ] ER COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY SPRINK " [58.42mm] 0/A CUP -'.--._ 2" [66.55mm] HOLE IN CEILING f" [4.96mm] 3-7/16" [77.72mm] MAX. FACE OF F1TI1NG TO FACE OF CEILING DIMENSION 2-1/4" (57.15mm] MAX. FACE OF NIPPLE EXT. TO FACE OF CEILING DIMENSION Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor _______ Thread Approvals Sprinkler Identification (SIN) US Metric G5-80 Non Adjustable 34"(19mm) 17,42"(15mm) 8,0 115 34" NPT (193/4) 1 RA3412 G5-56 Non Adjustable 34" (19mm) ½" (15mm) 5.6 80 ½' NPT (R½) 1,2,34,5 RA3415 G5-42 Non Adjustable 3/4" (19mm) /16" (10mm) 4.2 60 ½' NPT (R½) 1 RA3413 G5-28 Non Adjustable 3,4"(19mm) 3/8"(l0mm) 2.8 1 40 ½' NPT (R1/2) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 1650F174°c and cover plate 135°F1570C only! 1" x 1/2" REDUCING TEE OR ELBOW 7" x 3/4" REDUCING ,( TEE OR ELBOW ONLY ILING I.4ZmmJ DIA CUP -_. " CEILING [19.05mm] MAX.] COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY SPRINKLER 2-1/4" [57.15mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION [4.96mm] COVER PLATE.' 3/4" [19,05mm] ADJUSTMENT ce FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS 7" x 7/2" REDUCING TEE OR ELBOW 1------- -I" - I RELIABLE P/N 6999991900 " X I BRASS NIPPLE EXT."-,, COVER PLATE: 3/4" [19.05mm] ADJUSTMENT Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler, For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable.,.For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper Reliabi (914) 829-2042 Corporate Offices e (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/14 P/N 9999970421 Pendent Pendent / HB (See Fig. 1) (See Fig. 2) Recessed FP Pendent Concealed (See Fig. 3) (See Fig. 4) Recessed Fl Pendent Horizontal Sidewall (See Fig. 5) (See Fig. 6) Bulletin 157 Rev. I abiLs Model F3QR Quick Response Dry Sprinklers 4. Features The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. Styles available Pendent Recessed FP Pendent Recessed Fl Pendent Concealed Horizontal Sidewall Recessed FP Horizontal Sidewall Recessed Fl Horizontal Sidewall 11/2" (38mm) escutcheon adjustment on pendent sprinkler. ½" (13mm) escutcheon adjustment on recessed sprin- kler with push-on! thread-off FP Model Escutcheon ring. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push-on! thread-off CCP Cover Plate. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with Fl Escutcheon. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51mm - to - 1219mm), in 1/4" (6mm) increments. See specific styles for correct A" dimension range. Available in a variety of plated and painted finishes. Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System Type Hazard Pendent Recessed Pendent Wet Pipe Light Recessed Fl Pendent Quick Dry Pi pe Ordinary CCP concealed All Preaction (R5714) Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light (R5734) I All Preaction 2. Certified by FM Approvals Style Response Sprinkler System Type Hazard Pendent Wet Pipe Light Ordinary, Recessed Fl Pendent Quick Dry Pipe Groups (R5714) All Preaction 1&2 Horizontal Sidewall Wet Pipe Recessed Fl Horizontal Sidewall Quick Dry Pipe Light (R5734) All Preaction 3. NYC MEA 258-93-E Horizontal Sidewall / HB (See Fig. 7) Recessed FP Recessed Fl Horizontal Sidewall Horizontal Sidewall (See Fig. 8) (See Fig. 9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler "A" Dim. 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments Sprinkler Escutcheon Bronze Brass (1) Chrome Plated Chrome Plated White Polyester 2) White Other finishes and colors are available on special order. Consult factory for details. cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Not available for HB escutcheons. I4 ILJ r'' System Tee NPT 2 1/8" Die. (54.0nvr] "A" Dimension Hole in Ceiling Adjustment Range —1/4" [-6.4mm] 1 43/64' Dio. 1 1/2' [38] +1 1/4" [+31.8mm] [42.5mm] Total Adjustment Sprinkler Con ;: : 4 t : I Escutcheon Escutcheon Ceiling Adjustment Nominal PositioA [4 1 .3mm] of Escutcheon protrusion 3"' Di.. [76.2..] NEW157FCCI Fig.1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/4" (-6mm) to +11/4 (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F30R Dry Recessed FP Pendent Sprinkler "A" Dim. 131/20 to 48" (89mm to 1219mm) in 1/4" (6mm) increments I Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester 2) White Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. __________ Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate 11) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (11 286°F(141°C) I 225°F(107C) I Blue Sprinkler cup and FP Escutcheon fabricated of steel and recommended for interior applications. t1t Listed and Certified only by cULus. Model F3QR Dry Pendent wIHB Escutcheon "A" Dim. 131/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments I Standard Temperature Ratinus Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High 1" 286°F(141°C) 225-F (107-C) Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. (I) Listed and Certified only by cULus- System Tee I" APT "A" Dlmoneten 2 1/2" [63.5mm] 0,0. Hole ,e Ce,I,flg Adjuotment Rongo 31(2[889m1n] [;: /2" [12.7mm] Escutheoe Ad). Ceiling Y ,_ 25.4] Escutcheon ot Escutch Adj Spr,nkler ition Con Escutcheon 1-1/4" [31.75mm] Nominal Protrusion [4 1.3mm] 2 13/64" (50.80mm] 50w1571'602 Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -½" (-12,7mm) to +1/2" (+12,7mm) "A" dimension adjustment range. *--,-- —H--- ________-' \ J System Tee _1"NPT 21/2"Dio. - [63.50mrn] J "A" Dimension Hole in Ceiling Adjustment Range 2 19/64" Do, [±6.35mm] [58.34mm] - - — - Nominal Position Sprinkler of Escutcheon ''' Cup Assembly Ceiling P,~Escutclheon 1/4" [6.35mm] f f I Escutcheon Adjustment I I I 1/4" [6.35mm] _J I _, 3 7/32 Did. Escutcheon Adjustment I [81.76mm] 1/2" (12.7mm) .J Total Adjustment N4W157FGO3 Fig. 3 Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 2. Model F30R Dry Pendent Concealed Sprinkler "A" Dim. 31/2 to 48" (89mm to 1219mm) in 1/4" (6mm) increments ((P (nur PIsit (1) Mniahaa (2) Standard Finishes Special Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome 1 Utilizes the 1/2" cover plate with 3/8" total adjustment. (2) Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) Intermediate (1) 175°F (79°C) 165°F (74°C) 150°F (66°C) Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) High (1) 286°F (141°C) 165°F (74°C) 150°F (66°C) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed Fl Pendent Sprinkler "A" Dim. 3/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (I) Sprinkler Escutcheon JCollar Chrome Plated Chrome Plated Chrome Plated White Polyester (2) White White " Other finishes and colors are available on special order. Consult factory for details. cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (1) 286°F (141°C) I 225°F (107°C) Blue (I) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 System Tee 1" NPT 2 1/2 Die. - [6.35rnre] "A Dimension Hole in Ceiling Adjustment Range ± 3/16 2 19/64 Din. - - - [±4.76mm] [58.34mm] Nominal Position of Conerplote p- Sprinkler / Cop Assembly L Coverplate 3 Ceiling Assembly Ceiling 3/16 [4.76mm] J Cnoerplote Adjustment 3/16' [4.76mm] 3 5 6 Cooerplote Adjustment [84 I 3n'ms] 3/8" (9.53 m] Total Adjustment NEWI57FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. - -' '- System Tee 2 1/2" Die. - 1" NPT [63.50mm] Hole in Ceiling 1 15/16 'A Dimension [49.2mm] - Adjustment Range ± /4' [±6.. mm] . 15/16 Norninal Position [23.8mm of Escutcheon I Sprinkler Cap Assembly 1 I 3 Ceiling - 1/8 Ceiling [3.2mm] 1/4" [6.35]] I Escutcheon Adjustment I 1/4' [6.35] _J Escutcheon Adjustment Escutcheon 1/2 [12.7mm] I Adjustment [72 2mm] 2 27/32" —H NEwl57FCO5 Fig. 5 3. Model F30R Dry Horizontal Sidewall Sprinkler I "A" Dim. I 2" to 48" (51 mm to 1219mm) in 1/4" (6mm) increments Fin ishAst" Sprinkler Escutcheon Bronze Brass (3) Chrome Plated Chrome Plated White Polyester (2) White Other finishes and colors are available on special order. Consult factory for details. cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Not available for HB escutcheons. 1 1/2' [38.10mm] Tote) Adjustment Ce,)1r1g 4" [101.60mm] Mi 1 1/4" [31.75mm] _________ 12' [304.80mm) M - H- Escutcheon Adjustment 1/4 [635mm] System Tee Escutcheon Adjustment I I" NPT 23/32" [53 18 [76.20mm] _ 2 1/8" Dio. 1/4 I [53.98mm] I Hole ieWall " [6.35mm] Sprinkler C Protrusion H "A' Dimension Adjustment Nominal Position Range - 1/4" [-6.35mm] of Escutcheon eesr,57r000 + 1 1/4 [+31.75mm] Hg. 6 Note: The sprinkler can protrudes ¼" when escutcheon is in nominal position. Escutcheon adjustment provides 1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Model F3QR Dry HSW w/HB Escutcheon "A" Dim. 131/2" to 48" (89mm to 1219mm) in ¼" (6mm) increments] Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High 286°F (141°C) 1 2250F (107°C) Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. 1" [25.4mm] - — Total Adjustment Coiling 1/2" [12.7mm] -f" Escutcheon Adjustment J .— 4" [101.60mm] Min. 12" [304.80mm) Mao, 1/2. [12.7 mm] — Escutcheon Adjustment - - 2 3/32 Tee 53 18mm] X-1 Di" Escutcheon Di.. Heir in Wall 1—I/4" [31.75mm] Wnmien) Protrusion \ Sprinkler Can "A" Dinmnn,en—. \ Encutcheen Adjustment " Nominal Position noe,m,ce; Range 'I' /2 of Escutcheon Hg. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -½" (-12.7mm) to +½" (+12.7mm) "A" dimension adjustment range. tt Listed and Certified only by cULus. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench prinkler Identification Number (SIN): R5734 Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in ¼" (6mm) increments I Finishes (I) Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester (2) White (1( Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Classification Sprinkler Tem- perature Rating Max. Ambient Temp. Bulb Color Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate)" 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (1) 2860F(141°C) 225°F(107°C) Blue t" Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 I 13/32' * 6 rE .35) I udjuotnent up -le 'n Wall C oim,nnicn N'T N n Po it H4 a l Hole in Wall E chesonion _____udjostrnent Rnngr ____________" (12.On,rn] SC ut ±1/4" cacutcheon Adjuutn,ant [±6.30nnn) — 1/4 [6.35] Escutcheon Adjunlm,nt 5y,trnn lee enrol,roe * . FOR mAcnoon MUTUAL (FM) - 6" FOR uNocnwninces Lueoeunoe,Es (01) Fig. 8 Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. Listed by cULus for Quick Response. Approved by FM for Standard Response, Recessed Horizontal sidewall sprinklers are listed with cULus for installation of mm. 4(100mm) - to - max. 6(150mm) below ceiling and approved by FM for installation of mm. 4(100mm) - to - max. 12" (300mm) below ceiling. Model F3QR Dry Recessed Fl Horizontal Sidewall Sprinkler "A" Dim. 31/2' to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes Sprinkler IlEscutcheon lCollar Chrome Plated White Polyester (2) Chrome Plated White Chrome Plated White (I) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (1) 286°F (141°C) 225°F (107°C) Blue (I) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 T CeiUng____ Escutcheon [3.m] System Tee Sprinkler Cup r;1 4 * I— 1 NFl As A ' 12 [304.Rrnrn]Mon. 2 1/2' Bid.j 1FT1J Hole Wall Position f Escutcheon Nominal I Escutcheon Adjustment T" Dimension NLWISYf'209 Adjustment R g Adjustment ± 1/4 [±635 ] 1/4 [635] * • FOR FACTORY MUTUAL (FM) Escutcheon Adjustment 4" - 6" FOR UNDERWRITERS LABORATORIES )UL) Fig. 9 Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of mm. 4" (100mm) - to - max. 6(150mm) below ceiling and approved by FM for installation of mm. 4° (100mm) - to - max. 12" (300mm) below ceiling. Technical Data: Orifice Size: ½" (15mm) Thread Size: 1" NPT per ANSI 132.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US I (Metric): 5.6 7(80) Product Description Reliable Model F3QR Dry Spnklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response spnkJers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preac- tion systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficienfly, due to a tire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. 5. Ordering Information Specify: 1. Sprinkler Type (select one): Model F3QR Dry Pendent Model F3QR Dry PendentlHB Model F3QR Dry Recessed FP Pendent Model F3QR Dry Recessed Fl Pendent Model F3QR Dry Concealed Pendent Model F3QR Dry Horizontal Sidewall Model F3QR Dry Horizontal Sidewall/HB Model F3QR Dry Recessed FP Horizontal Sidewall Model F3QR Dry Recessed Fl Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (Fl or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in 1/4" (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI 132.1 [71/2 threads approximately]. All platings and paintings are decorative and intend- ed for interior use. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC*, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and for the fitting. Refer to Fig. 11. During installation, the following steps must be followed Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XL02 Sprinkler Wrench as specified. Install the Model FP push-on I thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed In- stallation Instructions The Model XL02 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard ½" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb sup- porting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) rel RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INS1AIJ. I INCH NPT THREADED ,/—END OF DRY PENDENT SPRINKLER AMBIENT TEMPERATURE OF PROTECTED AREA- AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 4OF/4C I 5oF/1oc I eor/ic EXPOSED MINIMUM BARREL. LENGTH" (FACE OF TEE TO TOP OF CEILING) IN. (MM) IN. (MM) IN. (MM) 417F(4C) 0 0 0 3OF (—VC) 0 0 0 2OF (—TC) 4 (lOT) 0 0 lOF (-12C) 8 (203) 1 (25.1) 0 OF (—ICC) 12 (305) 3 (75) 0 —bE (-23*C) 14 (356) 4 (101) I (25.1) —201' (-2c) 14 (356) 6 (152) 3 (75) —30F (-34'C) 16 (406) 8 (203) 4 (101) —4OF (-40-C) 18 (457) 8 (203) 4 (101) —50'F (-46C) 20 (508) 10 (254) 6 (152) —6UF (-51-C) 20 (508) 10 (254) 6 (152) wtl rirt UNIV THE 1 INCH FUrl bUilt OUTLET OF A MALLEABLE IRON TEE FTI1N0 PER ANSI B 16.3 (CLASS 150) OR CAST IRON THREADED TEE FITTING - 4 PER ANSI 16.4 (CLASS 125) ONLY. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION. FOAM INSULATING TAPE OR EQUWALENT, MINIMUM EXPOSED (HEATED AREA) r_SEAL THE CLEARANCE SPACE BARREL ARCJJ4D THE SPRINKLER TO AVOID LENGTH LEAKAGE OF AIR INTO THE PROTECTED OF AREA AND CONSEQUENT FORMATION COULD CONDENSATE AND THE FRAME, WHICH INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. 'A' CLEARANCEi. I DIMENSION HOLE I I I THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. "ThE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE A DIMENSION. NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH CEIUNG WIND VELOCITIES IN THE PROTECTED ARE/ (PROTECTED AREA) T I *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE Eti4- (HEATED AREA) (HEATED AREA) I+1 I MIND" MINIMUM EXPOSED I I I EXPOSED BARREL I BARREL LENGTH (SEE ABOVE DECKTTTE FLASHING RASCO #4003910 (RECOMMENDED) ,- INSIDE FACE - i .. [SEAL I LENGTH I (SEE ABDVD - ........:..'.....: CLEARANCE HOLE - :. INSULATED FREEZER. : S OR COOLER STRUCTURE OR EXTERIOR FRAMING ......................... INCOLDAREA I IN COLD AREA (PROTECTED AREA) DRY SPRINKLER (PROTECTED AREA) DRY SPRINKLER I NEW157F010 Fig. 10 7. FEMALL PIPE THREAL FEMAIJ PIPE THRE4L INTERNAL '?STRUCTION NO INTERNAL 'STRUCT/ON *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL 0H56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INCORRECT CORRECT CPVC ADAPTER • CPVC ADAPTER FITTING OR TEE FITTING OR TEE SHORTER INLET MALE PIPE THREA LONGER INLET MALE PIPE THREA MODEL F3-PL, MODEL F3QR-PL OR MODEL DH56 HSW-PL DRY SPRINKLER STANDARD MODEL F3, MODEL F30R OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION Fig. 11 .13 01 4 Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench Fig. 14- XL02 Wrench Hg. 15 -1-3 Wrench 91 Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Act Recycled ® (800) 431-1588 Sales Offices Paper Reliabl (914) 829-2042 Corporate Offices C (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address ES. Printed in U.S.A. 12/12 P/N 9999970175 Upright Vertical Sidewall Recessed Horizontal Sidewall Pendent Horizontal Sidewall \.. ., ..:• Concealed Pendent Conventional fr Recessed Pendent/F1/F2 L) Recessed Pendent/FP XLH Recessed Pendent F1 /F2 XLH Upright XLH Pendent Bulletin 014 Rev. N Reliable Model Fl FR Series Quick Response Glass Bulb Sprinklers 'Ta Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0,25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kIr Underwriters Laboratories Inc. and Certified for Product Description Canada (cULus). Reliable Model F1FR series sprinklers FM Approvals (FM) are quick-response automatic sprin- Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. VdS SchadenverhUtung GmbH (VdS) Model F1FR series sprinklers are Stan- NSF Certified to NSF/ANSI Standard 61 Annex G dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed (NSF) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- s tional sprinkler which is an Old-style!Conven- PendentFP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Model F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb. These sprinklers have demonstrat- UL Listing Category ed response times in laboratory tests which are five to ten Sprinklers, Automatic & Open (VNIV) times faster than standard response sprinklers. This quick Quick Response Sprinkler response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model Fl FR series sprinkler. Model El and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model El FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model COP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model COP with Model Fl FR56 Concealed Pendent and Model Fl FRS6LL Concealed Pendent sprinklers or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter D t fl eecor p / Orientation Nominal Sprinkler S Height Installation Wrench SIN mm Listings and Approvals Approval Notes US Metric inches mm inchesi F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 0 RA1418 VdS Recessed Pendent 2.25 1 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 0 RA1423 cULus 1,2 F1FR42LL 4,2 60 7/16 10 Pendent 2.25 57 . D RA1410 cULus, NSF ___ Recessed Pendent 2.25 1 57 GFR2 IRA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 0 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 D RA1414 cULus, FM, LPcB,Vds,Ec 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 Conventional 2.25 57 (Pendent or Upright)" D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white, Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. ci Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1070C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- __________ Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus F1FR42LL Pendent -- cULus, NSF -- _________ Recessed Pendent -- cULus, NSF -- Pendent cULus Fl FRXLH Recessed Pendent cULus -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- F1FR56 Concealed Pendent* cULus cULus,VdS,EC I cULus -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB VdS EC Pendent -- cULus, NSF -- F1FR56LL Recessed Pendent -- cULus, NSF -- _________ Concealed Pendent* -- cULus, NSF -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal cULus, FM -- [F1 I Sidewall__ FRS6 Vertical Sidewall(Pen- dent or Upri ht) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (570C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model Fl (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment Fl FR28 Recessed Pendent cULus cULus cULus RA141 1 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS,EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 2 7/4" HOLE 0/A. [5 7.2mm] I" X 1/2" REDUCER I 75/76" 0/A [49.2mm] L—_—_+------ 1 / (1 Fl ESCUTCHEON 8 J T AT MAXIMUM RECESS = 7/8(22.2mm] [3.2mm] "(41.3mm] / AT MINIMUM RECESS = 1-5/8 r F2 ESCUTCHEON ESS 1-1/8"[28.6mm] I AT MAXIMUM REC = AT MINIMUM RECESS = 1-5/8"(4 1.3mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS Fl ESCUTCHEOIj j2J 3/4"[lgmm] ADJUSTMENT F2 ESCUTCHEON 1/2(12.7mm] N-- ADJUSTMENT f FACE OF FITTING TO FACE OF CEILING DIMENSION F? ESCUTCHEON AT MAXIMUM RECESS 1(25.4mm] AT MINIMUM RECESS = 3/8[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4[19mm] AT MINIMUM RECESS = 3/8[9.5mm] 2 27/32" 0/A. [72.2mm] Fig. 1 Model F1FR56, F1FR561-L, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon L—_—_---_ _---I 1 X 112 REDUCER HOLE IN CEILING CUP AT MAXIMUM RECESS CEILING FACE OF FITTING 'T25.4mml TO FACE OF CEILING DIMENSION Im] AT MINIMUM RECESS = 1 AT MINIMUM RECESS = 1 "[25.4mm] 5'2"[12.7mm] JAr AT MAXIMUM RECESS = 9/16T14.3mm] ADJUSTMENT 31/4"DIA. [82,6mm] Fig, 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5' FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8 '79. 5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8 "[9.5mm] 2 1/4" HOLE 0/A. [5 7.2mm] Ft ESCUTCHEON LL AT VIAAJIAA i_i"r',. - AT MINIMUM RECESS = 2- 1/16"[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[41.3mm] '-1/8" AT MINIMUM RECESS = 2- 1/16"[52.4mm] [3.2mm] 1" X 1/2" REDUCER I 1 15/16" 0/A [49.2mm] LL 2 27/32" 0/A. [72.2mm] I (1) 4"-12" [10 1.6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. Ft ESCUTCHEON 3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT Ot3E RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW IT 2 5/8" CIA. 2 5/16" CIA - ________________ HOLE IN CEILING CUP 1 1/2" MAX. FACE OF FITTING _TO FACE OF CEILING ,,,.. DIMENSION CEILING 1/2" MAX. 5 COVER ADJUSTMENT 15/16" COVER PLATE -" ASSEMBLY SPRINKLER 3 5/16" CIA. CONCEALED, 1/2" ADJUSTMENT O17FGO1A Fig.4 Model Fl FR56iF1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model COP cover plate I" x 1/2" REDUCING TEE OR ELBOW —EaF 2 5/16" 0/A CUP - 1' / CEILING 5/16" MAX. r COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER 11 DIA. CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" CONCEALED, 5Z16" ADJUSTMENT 017 FCC 2A Fig, 5- Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model COP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate111 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate 11 Electroless Nickel PTFE(7) Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(216) Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR40][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][ 175°F (79-C)] [200-F (93-C)] (286-F (141 -C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile COP 1/2-inch (12.7mm) adjustment][low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F(57°C)for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model Fl FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices ° Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper (914) 829-2042 Corporate Offices C (800) 848-6051 Sales Fax Revision lines indicate updated or new data. Reliabl www.reiablesprinkler.com Internet Address EG. Printed in U.S.A. 12/15 P/N 9999970300