HomeMy WebLinkAbout1287 CARLSBAD VILLAGE DR; ; FA160050; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160050 1287 CARLSBAD Job Address: VILLAGE DR Permit Type: FALARM Parcel No: 1561907007 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 8/31/2016 Approved: 9/7/2016 Issued: 9/7/2016 Inspector: Project Title: CARLSBAD PEDIATRIC SMILES T.I.: INSTALL A NEW FIRE ALARM MONITORING SYSTEM CONSISTING OF THE EQUIPMENT SHOWN IN HTE DEVICE LEGEND ON THE PLANS. Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: TSAI CHIN-ZONG&CHIN-CHIANG 1521 VIRGINIA RD SAN MARINO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 314 0 314 0 mploplop EHVERPRmEa FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS CASA DE LAS CAMPANAS T.I. NORTE DINNING & TERRACE 18755 W BERNARDO DRIVE RANCHO BERNARDO, CA 92.127 -FIRE ALARM SYSTEM MATERIAL DATA SHEETS FAl 60050 1287 CARLSBAD VILLAGE DR BILL OF MATERIALS SYSTEM SENSOR P2R 2-WIRE WALL MOUNTED HORN/STROBE CSFM# 7125-1653:0188 SYSTEM SENSOR P2RK 2-WIRE CEILING MOUNT WEATHERPROOF HORN/STROBE CSFM# 7125-1653:0187 Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115,135, 150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting I R! 631NP77"M V , Nirl'. The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNAUNG & <~> MEA LISTED APPROVED approved 7125-1653:186 (indoor strobes) .7125-1653:188 (horn strobes. S4011 (chimes, hors strobes, horns) S5512 (strobes) 3023572 M0A452-05.E chime strobes) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuft'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 101093% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 1610 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminal Wire Gauge 1210 18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D (142 mm Lx 119 mm W x 33 mm 0) Wall-Mount Trim Ring Dimensions (sold as a5 pack) (TR-HS) 5.7"L x 4.8"W x 0.35'D (145 mm L x 122 mm W x 9 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 Cd. UL Current Draw Data IIT1T1lUL Candela Standard 15 Candela 15/75 Range 30 75 95 110 115 High 135 Candela 150 Range 177 185 8-17.5 Volts DC FWR 123 128 142 148 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 16-33 Volts DC FWR 66 71 77 81 94 96 158 153 181 176 202 195 210 205 228 207 246 220 281 251 286 258 i Sound Pattern Temporal Temporal Temporal Non-temporal Non-temporal Non-temporal Coded Coded Coded dB High Medium Low High Medium Low High Medium Low I] 8-17.5 Volts 16-33 Volts DC FWR DC FWR 57 55 69 75 44 49 58 69 38 44 44 48 57 56 69 75 42 50 60 69 41 44 50 50 57 55 69 75 44 51 56 69 40 46 52 50 I DC Input 8-17.5 Volts 15 15175 16-33 Volts 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 . - DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 - tSettings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions Wall-mount horn strobes SpectrAlert Advance Ordering Information Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" 1 Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no 'FIRE marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cc!" refers to strobes that include 135, 150, 177, and 185 candela settings. r57jfl 3825 Ohio Avenue • St. Charles, IL 60174 02514 system Sensor ,$ Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specdicat'ons subject to change without notice. Vat systemseasoccom for current product information. including the roost version at this data sheet. www.systemsensor.com AV0515201 • 1/14 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SVSTEl VII Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlerff Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIBNALING LISTED FM IIIEA 7300-1653187 (outdoor strobes) S4011 (chimes. horn strobes. lrorrrs) APPROVED approved 7125-1653:188 (horn strobes. Chime strobes) S3593 )outdoor and alert Strobes) 3023572 MEA452.05-E 7135-1653189 (horns, chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 1/4-inch top and bottom conduit entries and 3/4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash cer second Nominal Voltage Regulated 12 DC/F\NR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7W x 1.3"D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1 "W x 2.0'D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSO12O1 UL Current Draw Data Amwamxwam 1 I ®G 1 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR - DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 Candela 150 Range 177 185 NA NA NA NA NA NA NA NA 228 246 281 286 207 220 251 258 Coded Coded Medium 44 51 56 Low 40 46 52 69 50 Ia®rn D DC Input 8-17.5 Volts 15 15/75 16-33 Volts 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data 113=00=111 agomd2z 8-17.5 16-33 Switch Sound Volts Volts I 24-Volt Nominal Reverberant Anechoic Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams I! Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information ... Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK°t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-F" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. @20 2 Systern Sensor, 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change aathootroace. Vail sysleraserrsorcora \ SENSORe Phone: 800-SENSOR2 • Fax: 630-377-6495 for carre,rt product aforrcvorracluderg halves! version of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0187 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 660C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division