Loading...
HomeMy WebLinkAbout2800 WHIPTAIL LOOP; ; FPC2018-0220; Permit:Jg (City of Carlsbad Iftfl Print Date: 04/20/2022 Permit No: FPC2018-0220 Job Address: 2800 WHIPTAIL LOOP, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091202500 Track 1*: Applied: 07/17/2018 Valuation: $747,508.72 Lot #: Issued: 07/31/2018 Occupancy Group: Project #: Finaled Close Out: 04/20/2022 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: SPEC SUITE -BLDG C -SPRINKLER TI (184 HEADS) 16,072 SF OFFICE Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST P0 WAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $634.00 Total Fees: $634.00 Total Payments To Date: $634.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE SPRINKLER SYSTEM MATERIAL SUBMITTAL BUILDING "C" SPEC SUITE TENANT I M PROVEM NT 2800WHIPTAIL LOOP CARLSBAD, CA I Ic1cI.1 7nWtiiN FOWAY, CA. 92064A 95241 PH. (858)5 1 3-4949 Fx. (858)513-1322 PIPE M -COAT Specifications Nominal I.D. Nominal I Wt. i Wt. (H2fl) 'CRR' In;rnrn O.D. In; mm Wall In; mm Lbs/Ft; kg/rn b1rIkg/m 1.315 f4(, 0.133 1680 2.05 25 33.4 26.6 3.38 . 3.05 - 1114 1.380 ' 2.270 2.93 32 42.1 35.1 3.39 4.36 - 11/2" 1.900 1.610 ,..-1145 'sZ,Q_,__, 3.61 40 48.3 40.9,-s 3.68 5.37 - 2.375 0.154 3.656 -...,5.1 1 50 60.- 52.5 3.91 5.4 21h" .-'iäis 2.469 0.203 5.80 7.86 -. 1 73 62.7 5.16 8.6 11.73 6 I 6.625 6.357 I 0.134 I 9.3 I 23.03 F0251 150 168.3 161.5 I 3.40 I 13.8 I 34.27 o o.ui., O.'+T U. 00 U.0 'IV..) .O.)U.) 200 219 209.50 4.78 25.2 59.75 - When you specify Allied Schedule-10/Schedule-40 - M-COAT sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40- M-COAT gives you the extra quality assurance you demand. Our Sch-1 0 (11/4"-8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. ® Galvanized Pipe Schedule-10/Schedule-40 - M-COAT product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A- 123. ® Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products up to 4.500" in diameter are coated with M-COAT, an advanced MIC coating that is FM approved for use in hybrid sprinkle systems. ® American made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Schedule-10/Schedule-40 - M-COAT pipe are in compliance with the following: ASTM A-i 35, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com (70"Yallied • 16100 S Lathrop Ave. e 11350 Norcom Rd. • 2525 N 27th Ave. TUBE & CONDUIT' Harvey, IL60426 Philadelphia, PA 19154 Phoenix, AZ 85009 A PART OFfr ,,IOf 02013 Atkore International, Inc. All Rights Reserved. STP-S4-3-1301 MEGA-FLOW SPECIFICATIONS NIPS NOM OD NOM ID UL CRR MEGA-FLOW Schedule Schedule Schedule Mega-Flow Mega-Flow Nominal Pcs./Luft 10 40 40 wt./ft. 11/4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 1% 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 2% 2.875 2,707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 - 3.349 19 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 .75 1.00 8.000 10 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). MEGA-THREAD SPECIFICATIONS NPS NOM OD NOM ID UL CRR MEGA-THREAD Mega-Thread Schedule Mega-Thread Schedule L.W.T. Pipe Nominal ' Pcs./Lift 1 1.315 1.087 1.049 1.00 1.00 .61 1.462 70 1% 1.660 1.416 1.380 1.00 1.00 .39 1.989 51 11/2 1.900 1.650 1.610 1,00 1.00 .31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 .25 3.094 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). (9 C& APPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Mega-Flow steel fire sprinkler pipe is FM Approved for roll-grooved, plain-end and welded joints for wet systems; and UL, C-UL and FM Listed for use with roll-grooved, plain- end couplings and welded joints for wet, dry preaction and deluge systems. Mega-Thread is FM Approved for use in wet systems and is UL, C-UL and FM Listed for wet, dry and preaction sprinkler systems. Approvals and Specifications Both products meet or exceed these standards: ASTM A795, Type E, Grade A NFPA 13 and NFPA 14 Mega-Thread is approved for standard hanger spacing Manufacturing Protocols Mega-Flow and Mega-Thread are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Mega-Flow black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Mega-Thread is hot-dip galvanized to meet FM requirements for dry systems and is safer to weld than many zinc-coated, light-wall threadable products. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. 111111111111111111 IL TiI1 I PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: El MEGA-FLOW-BLACK El MEGA-THREAD-HOT-DIP GALVANIZED tZM G&q0@1@d Tube A DIVISION OF ZEKELMAN INDUSTRIES FITTINGS 0 1 Ductile iron Threaded Fittings SM1TH,.,.000PE9 INTERNATIONAL Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP Ductile iron castings conform to ASTM A536 c ® L us LISTED Fitting dimensions conform tc ASME B16.3 Bushings arid plugs conform to ASME B16.14 < > Fittings are 10% air tested APPROVED N?T threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 emperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fillings -20 to 100 500 150 500 200 ---480----..- 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 L eN ri Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 60 0.5 1.31 30 1 3513010 1.50 25 SO 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 351 3014 1.94 10 20 1.5 .2 35T 3P20 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 c®us APPROVED Fig. 35E 390° Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 5E 3 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 - 2 35E 3020 2.25 10 77 20 1.8 2-1/2 02 35E 34 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4x 1/2 35RE3006004 35RE3010004 35RE3010006 35RE3012004 35RE3012006 1.20 1.22 80 160 0.3 1 x 1/2 17i/4 1-1/4x1/2 1-1/4x3/4 1.26 1.36 70 140 0.4 1.38 1.45 50 100 0.4 0.5 1.34 1.53 35 70 1.45 1.63 35 70 0.6 1-1/4x1 1-1/2x1/2 1-1/2x3/4 1-1/2 x 1 1-1/2x1-1/4 TX-1 / 2 2x3/4 2 x 1 2x1-1/4 35fRE3012010 35RE3014004 35RE3014006 1.58 1.67 - 30 60 0.7 1.52 - 1.52 1.65 1.82 1.75 30 60 0.6 1.75 25 50 0.7 35RE3014010 35RE3014012 35RE3020004 35RE3020006 1.80 20 18 18 40 36 36 0.8 1.0 1.0 1.0 1.88 1.60 1.60 1.97 1.97 18 36 35RE3020010 35RE3020012 1.73 1.90 2.02 2.10 16 12 32 24 1.2 1.3 2x1-1/2 2-1/2 x 1-1/2 35RE3020014 35RE3024014 2.02 2.16 2.39 2.16 2.51 10 6 20 12 1.5 2.2 2-1/2x2 35RE3024020 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 -1- 1-1/4 1-1-12- 2 2-1/2 35F 3004 - OF 3006 35F3010 35F3012 35F3014 35F3020 35F3024 0.88 150 80 40 300 160 80 0.2 _75- 0.5 --d.98 1.13 1.29 25 50 0.7- 1.0 1.6 2.7 1.44 1.69 1.95 20 40 20 8 10 4 111 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 9 wwwsmithcooper.com Fig. 35RT3 - Reducing Tee c®us <> APPROVED CO Size in Part Number in B in C in Packj Weight lb Inner Master 3/4x1/2 lx1/2 lxl/2x1 1 x3/4 1 x3/4x3/4 1x3/4x1 1-1/4 x 1/2 1-1/4 x 1/2x 1-1/4 1-1/4x3/4 35RT3006004 1.20 1.20 1.22 60 30 30 120 60 60 50 0.4 0.6 0.6 0.6 0.6 35R13010004 35RT3010004010 35RT3010006 35RT3010006006 1.26 1.50 1.26 1.36 1.36 1.59 1.38 1.38 1.50 1.38 1.31 1.45 1.45 25 35 70 35RT3010006010 35RT3012004 35RT3012004012 35RT3012006 1.45 1.50 1.53 1.75 25 20 50 40 0.7 1.34 1.34 0.8 1.75 1.53 25 50 30 40 30 50 0.9 0.9 1.0 1.0 0.7 1.45 1.75 1.45 1.62 1.62 1.75 15 20 1-1/4x314x1-1/4 1-1/4x1 1-1/4x1x1/2 35RT3012006012 35R13012010 1.58 1.58 1.67 15 25 35RT3012010004 1.34 1.26 1.53 - 1-1/4x1x3/4 1-1/4 x1x1 35RT3012010006 1.45 1.38 1.63 20 40 40 0.8 0.9 35RT3012010010 1.58 1.50 1.69 20 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 1-1/2x1/2x1-1/4 1-1/2x 1/2x 1-1/2 35RT3014004 1.41 1.81 1.41 1.56 1.66 1.88 16 24 32 48 1.0 1.1 35RT3014004012 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35R13014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 1-1/2x3/4x1-1/2 35RT3014006012 35R13014006014 1.94 1.66 1.88 20 40 1.1 1.94 1.75 1.94 18 36 1.2 1.2 0.8 0.9 1.0 1-1/2x1 1-1/2x1x1/2 1-1/2x1x3/4 1-1/2x1x1 35RT3014010 35RT3014010004 35RT3014010006 35RT3014010010 1.65 1.44 1.50 1.65 1.65 1.25 1.80 1.69 1.75 1.80 12 20 16 24 40 32 1.44 1.50 16 32 1-1/2x1x1-1/4 1-1/2 x x 1-1/2 40 35RT30110012 1.82 1.67 1.80 1.88 1.94 12 12 24 24 1.2 1.3 1.4 0.9 35RT3014010014 1.94 1-1/?x 1-1/4 1-1/2x1-1/4x1/2 1-1/2 x 1-1/4 x 3/4 1-1/2x1-1/4x1 1-1/2x1-1/4x1-1/4 1-1/2x1-1/4x1-1/2 - 2x1/2 2x3/4 2x1 2 x 1 x 2 2x1-1/4 35RT3014012 1.82 1.82 1.34 1.88 1.66 12 16 24 32 35RT3014012004 1.41 35RT3014012006 1.52 1.45 1.75 16 32 1.0 35R13014012010 1.65 1.58 1.80 1.88 16 14 32 28 28 20 20 16 16 16 16 1.1 1.3 1.4 1.5 35RT3014012012 1.82 1.75 35RT3014012014 35RT3020004 1.94 1.49 1.88 1.94 1.88 14 10 10 8 8 8 8 1.49 1.60 1.73 2.02 1.90 35R13020006 1.60 1.97 2.02 2.25 2.10 1.6 1.7 1.9 1.9 2.0 35RT3020010 1.73 2.25 1.90 35R13020010020 35RT3020012 35R13020012020 2 x 1-1/4 x 2 2.25 2.10 2.25 2x 1-1/2 - 2x1-1/2x 1/2 2 x 1-1/2 x 3/4 2x1-1/2x1 2x 1-1/2x 1-1/4 2x1-1/2x1-1/2 35R13020014 35RT3020014004 35RT3020014006 2.02 2.02 1.41 1.52 2.16 1.88 1.97 8 10 10 16 20 20 16 2.1 1.3--1.4 1.5 1.49 1.60 35RT3020014010 1.73 1.65 2.02 8 8 8 35RT3020014012 35RT3020014014 1.90 2.02 1.82 2.10 2.16 16 16 1.7 1.8 1.94 11' Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35B13006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 358T3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x 1 x 1-1/2 35BT30010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35813012020 2.10 2.10 1.90 10 ?0 1.6 1-1/2x1-1/4x2 35B13014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 9 wwwsmithcooper.com 112 cous APPROVED Fig. 35CP3 - Straight Coupling with Ribs LISTED Size Part Number A in Packing Weight lb Inner Master 350P3004 1.38 200 400 0.1 3/4 5163 0 __'___26_0 200 02 1 35CP3010 60 120 0.4 1-1/4 35çP3o12 2.00 70 0.5 2.19 - 1-1/? 35CP3014 - 25 0.7 2 35CP3020 15 30 2.62 2-1/2 350P3024 3.00 9 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 2x 1 (not hex) I 35RC3020010 1 2.81 20 40 1 1.0 Fig. 35U 3- Union with Brass Seat Size in Part Number ____in A Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1:0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U I 3014 2.62 101. 20 1.7 2 _35-050-26--j-3.12 6 12 2.4 Fig. 35HB3 -Hex Bushing Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 ___ 1-1/4x1 35HB3010004 35HB3010006 3FT%4.2Q1 1.06 1.06 180 180 360 360 0.2 0.1 1.19 90 180 0.2 1-1/2x1-1/4 35HB3014010 35HB3014012 -42 1.25 Th 150 04 150 0.3 2 x 1 2x1-1/4 35HB3020010 35H83020012 35H83020014 138 1.38 40 - 40 0 80 06 0.6 2 x 1-1/2 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 1-1/4 1-1/2 2 35SP3004 35SP3006 35SP3010 35SP3012 35SP3014 35SP3020 0.94 600 1200 0.07 1.12 1.25 350 200 700 400 0.1 0.1 1.37 1.44 1.50 100 80 45 200 160 0.3 0.4 90 0.6 113 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.corn c®uS <e> APPROVED LISTED Size Pad Number A in Packing Weight lb Inner I Master - 1 3010 1.50 20 - 40 0.9 1-1/4 35XX 30 1.75 12 24 1.4 16 1.8 1-1/2 35X3014 1.9 8 2 30 35X 20 2.25 6 12 2.8 Fig. 35X 3- Cross lio Fig. 35RX3 - Reducing Cross Size Part Number A in B in Packing Weight lb Inner Master 1-1/4x1 1-1/2x1 2 x 1 35R 35RX3014010 35RX3020010 1.67 1.8 2.02 1.58 5 1.73 15 30 1.2 12 24 1.4 6 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35C 3004 35C 3006 0.87 0.97 300 -- 200 600 400 0.1 0.1 1 1-1/4 14/2 3503010 35C 3012 35C 3014 1.16 1.28 1.33 110 70 50 220 140 100 0.2--- 0.4 0.5 2 2-1/2 35C 3020 35C 3024 1.45 25 1 8F 50 36 0.8 1.70 1.6 Fig. 35BC3 - Beam Clamp ize in Part Number A in Packing Weight lb Inner I Master 3/8 1/2 358C3003 35BC3004 0.75 100 200 - 160 0.3 0.5 Il SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com 114 SPRINKLER HEADS tqco Ffre Protection Products Worldwide www.tyco-fire.com Contacts I Model ESFR-25 252 K-factor Pendent Sprinkler Early Suppression, Fast Response General Description TYCO Model ESFR-25 Pendent Sprin- klers are Early Suppression, Fast Response (ESFR) sprinklers having a nominal K-factor of 25.2 (Ref. Figure 1). They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Sprinklers are pri- marily used for ceiling-only sprinkler protection of (but not limited to) the fol- lowing storage applications: most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards some storage arrangements of rub- ber tires, roll paper, flammable liq- uids, aerosols, and automotive components For more specific criteria, refer to Table A as well as the applicable design standard. The Model ESFR-25 Pendent Sprin- klers provide the system designer with hydraulic and sprinkler place- ment options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprin- kler has been designed to operate at substantially lower-end head pres- sures, as compared to ESFR Sprinklers IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as possi- bly reducing or eliminating the need for a system fire pump. Also, Model ESFR-25 Sprinklers permit use of a maximum deflector-to-ceiling distance of 18 inches (460 mm) versus 14 inches (356 mm). Additionally, a storage arrangement of 40 ft. (12,2 m) with a ceiling height of 45 ft. (13,7 m) does not require in-rack sprinklers as do other ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. The Model ESFR-25 Sprinklers are listed by Underwriters Laboratories (UL) for specific applications with a maximum storage height of 43 ft. (13,1 m) with a maximum ceiling height of 48 ft. (14,6 m) without the requirement for in-rack sprinklers. Refer to the Specific Application Listing (UL) for the design criteria. Applications for the TYCO ESFR Sprin- klers are expanding beyond currently recognized installation standards. For information on research fire tests (e.g., with flammable liquids and aerosols) that may be acceptable to an author- ity having jurisdiction, contact Tyco Fire Protection Products (TFPP) Technical Services. L(.)tLii The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities having jurisdiction (e.g., FM Global). Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard, or other applicable standard, must be referenced to ensure applicability and to obtain complete installation guide- JULY 2016 lines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) TY9226 TY9226 is a re-designation for Central SIN 9226, Gem SIN G8441, and Star SIN S8010. Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved NYC Approved under MEA 356-01-E LPCB Certified (Cert. Nos. 094b and 0071) CE Certified (Certificate of Conformity 1725-CPD-HOO1 0) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connections 1 Inch NPT or ISO 7-R 1 Discharge Coefficient K=25.2 gpm/psi½ (362,9 1pm/bar½) Temperature Ratings 165°F (74°C) and 212°F (100°C) Finish Natural Brass TFP3I2 TFP3I2 Page 2 of 4 7 1" NPT Components: 8 ' t 1-13/16 1 - Frame / 9/16 (46,0 mm) 2 - Deflector / / (14,3 mm) 3 - Compression 9 NOMINAL Screw MAKE-IN - 4-Hook 6 5 - Strut 3-13/16 6 - Link Assembly 5 (96,8 mm) THERMAL 7 - Button 8 - Sealing SENSING ELEMENT Assembly 4 = 9 - Ejection Spring WRENCH ' I FLATS I 3- / 2 TEMPERATURE 72(50,8 RATING mm) —1 FIGURE 1 MODEL ESFR-25 PENDENT SPRINKLER, 25.2K EARLY SUPPRESSION, FAST RESPONSE Storage Type NFPA FM Global Open Frame (i.e., no solid shelves) Single, Double, Multiple-Row, or Portable Rack Storage of Refer to NFPA 13 Refer to FM Global Class l-IV and Group A or B Plastics Chapters 16 and 17 2-0 and 8-9 Solid Pile or Palletized Storage of Refer to NFPA 13 Refer to FM Global Class l-IV and Group A or B Plastics Chapters 14 and 15 2-0 and 8-9 Idle Pallet Storage Refer to NFPA 13 Refer to FM Global Chapter 12 2-0, 8-9, and 8-24 Rubber Tire Storage Refer to NFPA 13 Refer to FM Global Chapter 18 2-0 and 8-3 Roll Paper Storage Refer to NFPA 13 Refer to FM Global 8-21 (Refer to the Standard) Chapter 19 Flammable/Ignitable Liquid Storage (Refer to the Standard) Refer to NFPA 30 Refer to FM Global 7-29 Aerosol Storage (Refer to the Standard) Refer to NFPA 30B Refer to FM Global 7-31 Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only; refer to the Standard) Chapter 20 N/A - Not Applicable TABLE A MODEL ESFR-25 PENDENT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TFP3I2 Page 3 of 4 Physical Characteristics Frame .............................Brass Deflector ..........................Bronze Compression Screw ..........Stainless Steel Hook ............................MONEL Strut.............................MONEL Link Assembly................Solder, Nickel Button .............................Brass Sealing Assembly. Beryllium Nickel w/TEFLON Ejection Spring ..................INCONEL Operation The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. Design Criteria The following general guidelines pro- vided for the TYCO Model ESFR-25 Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ. Consequently, the appropri- ate standard must be used for a given installation. In all cases, the appropriate NFPA or FM Global installation standard must be referenced to ensure applicabil- ity and to obtain complete installation guidelines. The following general guidelines are not intended to provide complete installa- tion criteria. In addition to this technical data sheet, the following data sheets describe other TYCO ESFR Sprinklers: TFP315 Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler TFP316 Model ESFR-17 (TY7126) K=16.8 Upright Sprinkler TFP317 Model ESFR-17 (TY7223) K=16.8 Pendent Sprinkler TFP318 Model ESFR-1 (TY6226) K=14.0 Pendent Sprinkler TFP319 Model ESFR-14 (TY6236) K=14.0 Pendent Sprinkler System Type Wet Pipe Roof Construction Unobstructed or obstructed con- struction (e.g., smooth ceiling, bar joists, beam and girder, and so forth). Where the depths of the solid struc- tural members (e.g., beams and stem) exceed 12 inches (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 inch rise for 12 inch run (16.7%) Maximum Coverage Area 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Coverage Area 64 ft2 (5,8 m2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 feet (3,7 m) for building heights up to 30 feet (9,1 m) 10 feet (3,1 m) for building heights greater than 30 feet (9,1 m). In some cases, installation standards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Minimum Clearance to Commodity 36 inches (914 mm) NFPA Deflector-to-Ceiling Distance 6 to 18 inches (152 to 457 mm) FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Specific Application Listing (UL) TYCO Model ESFR-25 Pendent Sprin- klers are listed by Underwriters Labo- ratories (UL) for Specific Applications with a ceiling height greater than 45 ft. (13,7 m) up to and includ- ing 48 ft. (14,6 m), and a storage arrangement up to and including 43 ft. (13,1 m), the following guide- line are provided for the TYCO Model ESFR-25 Pendent Sprinklers: Sprinkler Position Pendent: Frame arms aligned with pipe Deflectors parallel with ceiling or roof System Type Wet Pipe only Maximum Area of Coverage 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Area of Coverage 64 ft2 (5,8 m2) according to NFPA 13 Maximum Slope Ceiling 2 inch rise for 12 inch run (16.7%) Maximum Spacing 10 feet (3,1 m) In some cases, the installation stan- dards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Temperature Rating 165°F (74°C) and 212°F (100°C) Deflector Distance from Walls Minimum of 4 inches (102 mm) from walls but no more than 1/2 the allow- able distance permitted between sprinklers Deflector to Top of Storage Minimum of 36 inches (914 mm) Deflector-to-Ceiling Distance 6 to 14 inches (152 to 356 mm) Maximum Ceiling Height 48 feet (14,6 m) Maximum Storage Height 43 feet (13,1 m) Storage Arrangement Palletized, solid piled, open frame, single row, or double row Commodity Class l-IV; Cartoned, unexpanded plastic Sprinkler System Design NFPA 13 for ESFR Sprinklers based upon 45 psi (3,1 bar) design pressure, 169 gpm (640 1pm) with 12 sprinkler remote area Minimum Aisle Width 5 feet (1,5 m) TFP3I2 Page 4 of 4 FITTING SIDE TOWARDS SPRINKLER FITTING WRE RE( FIGURE 2 W-TYPE I SPRINKLER WRENCH Installation TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Damage to the fusible Link Assem- bly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible Link Assembly), and by using the appropriate sprinkler wrench. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lbs-ft. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Note: Install the Model ESFR-25 Pendent Sprinkler in the pendent posi- tion (Ref. Figure 2). Step 1. With pipe thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pres- sure to the Link Assembly, and handle the Model ESFR-25 Pendent Sprinkler only by the Frame arms. Step 2. Wrench-tighten the Model ESFR-25 Pendent Sprinkler using only the W-Type 1 Sprinkler Wrench (Ref. Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats (Ref. Figure 1). Step 4. After installation, inspect the Link Assembly of each Model ESFR-25 Pendent Sprinkler for damage. In par- ticular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assem- bly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. Care and Maintenance TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Model ESFR-25 Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226), (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°c)..................58-441-1-165 212°F (100°C) .................58-441-1-214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-25, Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226) with ISO 7-1 thread connection, (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) .................. 58-442-1 -165 212°F (100°C) .................58-442-1-214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco MONEL and INCONEL are trademark of Special Metals Corporation. Fire Protection Products TEFLON is trademark of DuPont Corporation. N I FORE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT ° PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi 1,34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size Li QUICK RESPONSE UPRIGHT CONVENTIONAL cr. - QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL ()SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER CLASSIFICATION I BULB COLOR N.F.P.A. MAXIMUM I TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C INTERMEDIATE 175FI200°F 79C/93'CH ORANGE/RED 100°F 38°C I YELLOW/GREEN 150°F 66°C I HIGH 286°F 141°C BLUE 225°F 107°C APR 2017 GFS-100a (Formerly A-20) QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome Whit:ste 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) I 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16". °FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEAIOI-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X -- -- -- X GL4215 4.2 LH X X X X X X -- -- -- X JPRIGH1') t3L5615jQ H/OH) X 0 X 0 X X X X X X 8.0* LH/OH X X X X X X -- -- -- X GL8115 0L8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X -- -- -- X GL4201 4.2 LH X X X X X X -- -- -- X PENDEN1 L5601)a H/OH) X 0 0 0 X X X X X X 8.0* LH/OH X X X X X X --- -- -- X GL8101 GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X -- -- -- SIDEWALLt GL8133 8.0 LH X X X X X X -- -- -- -- GL2826 2.8 LH X X X X X X -- -- -- X ORIZON ____IDEWAJL GL5627a 5.6 LH/OH X X X X X -- -- X X -- GL8127 8.0 LH/OH X X X X X X -- -- -- -- CONVENTIONAL GL5624 5.6 LH/OH X X X X X -- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X X -- --- X X -- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. aINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2"NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • Model Number • Style • Orifice products found to be defective in material or workmanship for a Thread Size • Temperature • Finishes desired period of one year from date of shipment. Quantity - Wrenches - PIN 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 9898464583 FAX 9898469231 Mdbom 1-800-248-0278 www.gIobesprinkler.com FIRE SPRINKLER CORPORATION APR 2017 PRINTED U.S.A. GFS-100a (Formerly A-20) HANGER & BRACES COMPONENTS Not less than - 2 nominal wdth Product Features li14 . ________________ No pre-drilling required. Not less than DWood Quick to install using the Sammy Ynominal °$- Nut Driver with an 18V cordless thickness (2-1/2") (depth or side drVdnver. of vertical member) Saves time from traditional Double Sheefrock methods. Ceiling I 7.Lf&' Reduces installation cost Made in the U.S.A. - ______ jTJ 1. 2 .: t1E1 • tØ) ijt1 1/4 8002957 1/4 8003957 - - 1/4' 8004957 3/8' - 8006957 3/8° 8007957 3/8° - 8008957 : 3/f 8068925 3/8' 8009925 - 3/8" 8010957 3/8' 8069925 3/8 8011925 3/8" 8012925 - 1/2 - 8013925 1/2" 8014925 1/2" - - - 8015925 1/2' 8016925 1!2" 8017925 GST 100 1/4 210 (7/16° OSB) 25 125 670 (3/4° Ply) GST 200 1/4x2° 1760 (Fir) 25 125 GST 300 1/4x3" 2060 (Fir) - - - - - 25 125 GST.75 1/4x3/4° 1/4x r 564 (3/4" Ply) - - 25 125 GST 10 (7/16°OSB) 300 25 125 - GST 20 1/4x2 1760 (Fir) 850 1475 25 125 GST 20.S9 1/4x2° 1760 (Fir) 850 25 125 GST 25-380 3/8s2.1/2 2113 (Fir) 1500 25 125 GST 36 1/4x3 - 2060 (r) 1500 1475 25 125 #1491a GST 30-SS , 1/4x3° 2060 (Fir) , 25 125 Nut Driver Part #8113910 GST 40 1/4 x4 2180 (Fir) - 25 125 GST 60 1/456 2230 (Fir) 25 125 - GST 2 1/4x2 1760 (Fir) - 25 125 GST 2.5-380 3/8x2-1/2 2113 (Fir) - 25 - 125 GST 3 1/4x3 2275 (Fir) 25 125 GST4 1/4x4" 2180 (Fir) 25 125 GST 6 1/4 a 2230 (Fir) - 25 - 125 #14 SW Red Nut Driver Part # 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 Y2° x 12 pitch roof. • Reduces installation cost Allows 17° deflection from vertical. • Made in the U.S.A. ft t I!J11ffi tJJ1 JI lllo I. .z1t3 IU9I10 &AW l09 EJW) thi) flfliuD i j Q..°8 3/8' 8139957 SH.GST20 1/4x2 1257 (Fir) 1050 1475 25 125 125 3/8 8141957 SH.GST30 114x3 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. AR 1111, AONN%. W ~ __ __ V W-2 fl Not teas than 2' nominal width / Product Features (1-112') up to 3-1/2' pipe; not Less than No pre-drilling required. 3' (2-112') nominal width 4' & 5' pipe Floor Joist Quick to install using the Sammy Minimum 2-11z from bottom for branch lines. Minimum 3" from Nut Driver with an 18V cordless bottom for main lines. Exception: This drill/driver. requirement shall not apply to 2' or thicker naitng ships resting on top of J steel beanss Saves time from traditional methods. Reduces installation cost Made in the U.S.A. - - 1/4" 8018957 SWG 100 114x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4o 2" 1725 (Fir) 25 125 4 3/8" 8020957 -- SWG 10 - 1/4x 1" 622 (Fir) 300 25 - 125 ,).. 3/8' - 8021957 - SWG 20 1/40 2' 1725 (Fir) 1050 25 125 8073925 SWG 2O-SS 1/4x2" 1725 (Fir) - - 850 25 —125-- #14 SW Red 3/8" 8022925 SWG 25-380 3/8521/2" 2249 (Fir) 1500 25 125 Nut Driver - - 3/8" 8023925 SWG 3O 1/4x3" 1884 (Fir) - 25 125 Part # 8114910 1T)0N STEPS, IN7O;WOD'& STEL: IINSTALLATION STEPS - INTO WOOD & STEELI Insert the appropriate nut driver into a 3/8" or 112"portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 112"portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). Vilifh drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique Spin-Off feature which provides a fast and Safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Pipe Size Oty UL Listed Fastener Table Fastener Type Material 2' 2 #16 x 2' Drive screws Wood 2" 1 /t' Lag bolt Wood 21/2 - 4' 1 1/2" Lag bolt Wood 31/2" 2 1/4" x 11/2" Lag bolts Wood 4" 2 1/4' x 2' Lag bolts ** Wood 4" 2 1/4" x 1' Tek screws Metal (15 gauge) 4" 2 1/4" x 1' Tek screws Metal (16 gauge) ** No pre-drilling Up Upper Attachments Fig. 58 - Threaded Side Beam Bracket ®TDLCD Size Range: /8'-16 rod, pipe sizes 1/2' (15mm) thru 4" (100mm) .C®uS Material: Pre-Galvanized Steel USTE.D Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept /8' and 1/2" fastener B bolts. Per NFPA 13: 1/2' (15mm) thru 2' (50mm) pipe requires /8" fastener, 21/2' (65mm) thru 4' 1100mm) pipe requires 1/2" fastener.* Factory Mutual Engineering approved thru 4(100mm) pipe. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Order By: Figure number and finish A Finish: Pre-Galvanized *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below. 2-'/a"x Lag Bolts (No Pre-Drilling Up to 4" (100mm) pipe Per NFPA 1-3/n"or'/z" Lag Bolts Up to 4" (100mm( pipe 2-#16x2 Drive Screws 1/2" (15mm) -4(100mm) pipe - a) E CL CL 2- #14x 1" Tek Type Screws Larger pipe sizes can be hung with reduced spacing Part No. Pipe Size Rod A B C Approx. Wt.I100 in. (mm) Size in. (mm) in. (mm) in. (mm) Lbs. (kg) 53 1/2"-4" (15-100) /8"-16 2/4' (69.8) 11/2' 138.11 11/8' (28.6) 14 16.31 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 85 B-Line by 74i Threaded Accessories ®TOLCO' T TL Specify Length < TL T T h,ead Size B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: /8"-16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length IL 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x V 3/8"-16 21/2' (63.5) 730 (3.25) 572 12.541 B3205-1I2 X h/2"13 21/2' (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x 1 /8'-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x '1' /4"-10 3' (76.2) 3230 (14.37) 2530 (11.25) B3205-1/8 X '1' /8'-9 31/2' (88.9) 4480 (19.93) 3508 115.601 For larger sizes consult full line pipe hanger catalog AIR - All Threaded Rod - 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/8°-16 thru 11/26 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F 399°C Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Part No. - Size x Length ATR Fig. 99 Threads Per Inch Recommended Load Lbs. (kN) Approx. Wt./100 Ft. Lbs. (kg) AIR 1/4" x 120 991/4" x length 20 240 (1.07) 12 (5.44) AIR 3/a" x 120 993/8" x length 16 730 (3.24) 29 (13.15) AIR 1/2" x 120 99-1/2" x length 13 1350 (6.00) 53 (24.04) AIR /8" x 120 995/g" x length 11 2160 (9.60) 89 (40.37) AIR 3/4" x 120 993/4" x length 10 3230 114.371 123 (55.79) AIR 1/8" x 120 991/8" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog B-Line by nr.fJJ All dimensions in charts and on drawings are in inches. Dimensions shown In parentheses are in millimeters unless otherwise specified. Revised 4/28/2074 94 Fire Protection Solutions Fig. 200_21/2 to 200-8 Fig. 200 -/ 5 Fig. 200-1 to 200-2 Fig. 200S Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B311ONF) ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2 " (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2' (15) I8"-16 31/ (79.4) 2/8' (66.7) 11 (5.0) 200-/4 3/4' (20) /o"-i 6 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8'-16 3/8" (85.7) 2/8' (66.7) 12 (5.5) 200_11/4 11/4' (32) /8'-16 33/4' (94.0) 2/8' (73.0) 13 (5.9) 200-11/2 11/2' (40) /8'-16 3I8 (98.4) 2/8' (73.0) 14 (6.4) 200-2 2' (50) /8"-16 41/2 (114.3) 3' (76.3) 15 (6.9) 200-21/2 21/2' 1651 3/8"-16 5/8' (142.9) 41/8 (104.7) 27 (12.3) 200-3 3' (75) 3/8 -16 5/8 (149.1) 4' (101.6) 29 (13.3) 200-31/2 31/3' (90) /e'-16 7/8' (187.3) 51/4" (133.3) 34 (15.6) 200-4 4' (100) /8'-16 1/8' (187.3) 5' (127.0) 35 (16.0) 200-5 (125) 1/2'..13 91/8 (231.8) 61/4' (158.7) 66 (30.2) 200-6 (150) 1/2"_13 101/8' (257.2) 6/4' (171.4) 73 (33.4) 200-8 8' (200) 1/2'_13 131/8' (333.4) 8/4' (222.2) 136 (62.3) Al) dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by