Loading...
HomeMy WebLinkAbout6800 EMBARCADERO LN; ; FA160021; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160021 6800 Job Address: EMBARCADERO LN Permit Type: FALARM Parcel No: 2146500200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 5/18/2016 Approved: 5/26/2016 Issued: 5/26/2016 Inspector: Project Title: BLUWATER CREATIVE OFFICES VIBE INSTALLATION OF NEW STROB AND HORN STROBE DEVICES TO MEET ADA UPGRADES ON THE GROUND FLOOR. STROBE AND HORN STORBE DEVICES TIE INTO EXISTING REMOTE SIGNAL POWER SUPPLY. Applicant: RED HAWK FIRE & SECURITY 920 SOUTH ANDREASEN DR SUITE 102 ESCONDIDO, CA 760-233-9787 Owner: MACQUARIE POINSETTIA INC 1420 5TH AVE #2220 SEATTLE WA Fees ($) Add'I Fees ($) Total ($) Balance ($) 362 0 362 0 FIRE ALARM SYSTEM SUBMITTAL For 1EIF :[ 6800 EMBARCADERO LANE, BLDG 2, GROUND FLOOR, CARLSBAD, CA 92008 (•. Submitted By: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 ILE COPY FA160021 6800 EMBARCADERO IN STE. 100 PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 CONTRACTORS LICENSE: PROJECT MANAGER: PROJECT NAME: PROJECT ADDRESS: SCOPE OF WORK: C-10/C-16 #713099,11/30/16 John Stasukevich BLU WATER CREATIVE OFFICES 6800 EMBARCADERO LANE, BLDG 2, GROUND FLOOR, CARLSBAD, CA 92008 TENANT IMPROVEMENT May 16, 2016 Re: BluWater Creative Offices 6800 Embarcadero Lane, Bldg 2, Ground Floor, Carlsbad, CA 92008 Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinklered. OTY. MODEL NO. 6 SIGA-CTl 9 GCF-VM 2 G1F-VM 6 G1F-HDVM 7 GCF-HDVM 02 WG4WF-HVMC DESCRIPTION C.S.F.M. Single Input Monitor Module 7300-1657:0121 Multi Candela Strobe, Ceiling Mount 7125-1657:0219 Multi Candela Strobe, Wall Mount 7125-1657:0218 Multi Candela Horn Strobe, Wall Mount 7125-1657:0202 Multi Candela Horn Strobe, Ceiling Mount 7125-1657:0202 Multi Candela Horn Strobe, Weatherproof 7125-1657:0311 Respectfully Submitted, RED HAWK FIRE & SECURITY 40 __ [1 MEA(E Applicaton Notes 7300-1657: Available 0121 V2 SIGA-M EST Catalog t> Intelligent Input-Output '7Life Safety & Communications Input Modules SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 Overview Standard Features The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (lDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32°F to 158 OF (0 °C to 70°C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UlO modules. Two- and six-module UlO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UlO assemblies may be mounted in fl Edwards enclosures. Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. SIGA-CT1 HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (U 10) or standard 1-gang mount UlO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Stand-alone operation The module makes decisions and inputs an alarm from initiat- ing devices connected to it even if the loop controller's polling interrogation stops. (Function availability dependent upon control panel.) Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET 85001-0241 Not to bo used for installation purposes. Issue 8 Signature Series Overview The Signature Series intelligent analog-addressable system from .Edwards Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly main- tenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature de- vice measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1, SIGA-CT1 HT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) , \ 4 S "S is LEDs LED viewing ports •\ SIGA-MCT2: mount the UIO motherboard inside a suitable Edwards enclosure with screws and washers provided. Plug the SlGA-MCT2 into any available position on the motherboard and cure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 uto Motherboard 6-32 Self-tapping screws Plug-in (1-110) Captive Module screws #a Flat washers —Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SlGA-PRO Signature Program/Service Tool. Edwards recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or 'Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. DATA SHEET 85001-0241 Not to bx used for installation purpsss. Issue 8 uL/UIC Seed 47444(51 Ul/IJIC U,tod 47KW (01 J10(R) Ce/OO n,otherboord EI1IIIT] ____ Circuit T.to Out IJ/A r: I\i Red LED Wilve: '"N lNoconntions or/umper settings 1required for 0112. SlGA-MCT2 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), and #14AWG (1 .50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4,000 ft (1,219 m) #14 AWG (1.50 mm2) #12 AWG _(1.50_mm2) Typical N.O. Initiating Device Typical N.C. Initiating Device INPUT 1 INPUT 2 A AA Style B (Class B) StyteB(ClassB) 8 7 UL/ULC Listed • • 471<0 EOL UL/ULC Listed 471<0 EOL Red LED Green LED 471<0 EOL A A L\ A UL/ULC Listed X fl (Alarm/Active) —* © 4— (Normal) Red LED © © Green LED 4 3 2 1 (Alarm/Active) 4 3 2 1 (Normal) TB1 D0000L TB1 ( DATA IN I DATA I DATAIN(-)> jo DATA OUT (+) ___________________ ____________ DATA IN (~)>- DATA IN(-) > I From Signature Controller To Next Device __________________ ________ .DATAOUT(-)J DATA OUT (-) From Signature Controller Y To Next Device or Previous Device or Previous Device A A 3FlGA-CT1HT SlGA-0T2 NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc © 350 jA The SiGA-u1O6R and the SIGA-U102R do not came with TB1 4. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EST's Signature Series intelligent S processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Page 3 of 4 DATA SHEET 85001-0241 Not to be used for installation purposes. Issue8 Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.eom EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane, NC 27302 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Specifications Catalog Number SIGA-CT1HT SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses y'20TiA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates U102R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) to 0 F 0 to 49 Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog Description Ship Wt. Number . Single Input Module - UL/ULC Listed lbs (kg) 0.4 (0.15) SIGA-CT1HT Single Input Module High Temperature Operation UL/ULC Listed 0.4 (0.15) SlGA-CT2 Dual Input Module - ULJULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions SIGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0 (3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket (allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) 1.5(0.70) INK SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4 of 4 DATA SHEET 85001-0241 Not to he used for installation purposes. Issue 8 Life Safety tc Communications EST Catalog Strobes, Horns, Bells, Chimes Field Configurable , Ceiling Strobes One or more patents pending. FC MEA CE 7125-1657: 0219 S5389 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - idea] for long runs or existing wiring Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use I Page 1 of 4 DATA SHEET 85001-0557 Not to be used tar installation purposes. Issue 7 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing Scodes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/0 (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. +4 To listed To next fire alarm ___ appliance, ___I end-of-line panel M-- IT W control I MT or return to ' I control I equipment S I _ Page 2of4 Dimensions 6.8" dia. (173 mm) \ I (25 mm) 0.60(15 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output - 50 60 70 80 90 100 110 120 90' Angle— Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output candela switch (see ordering information). The output / setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. DATA SHEET 85001-0557 Not to be used for installation purposes. Issue 7 Light output setting, high output models tl95} or "1 or U15 or "B" or "A" RMS RMS RMS RMS 330 392 502 565 432 518 643 693 Light output setting, high output models U95 or "ID" or "1 or "B" "177" or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. I_il. Light output setting, standard models ''15'' or 11301' or 'IC" or "B" "95"or Rating RMS RMS RMS RMS 16 Vdc 109 151 281 318 16Vfwr 131 194 379 437 Typical Light output setting, standard models " or "D" "Oor "C" t25' or "B" 1195" or "A" Current RMS RMS RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 194 33 Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models g available. Lens Optical grade polycarbonate (clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8(54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceilina acolications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Strobe operating voltage GC-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc F\NR. GC-VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, i064, i05OO, Fireshield Plus 3, 5 and 10 zone. Add Gi M for G1-CVM &G1 -HDVM devices only. Page 3 of 4 DATA SHEET 85001-0557 Not to be used for installation pupases. Issue 7 Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Contact us... Model Housing I Marking I Lens Strobe Ship Wt. Email: edwards.fire@fs.utc.com Web: www.est-fire.com Life safety ADDliances (cfw runriinci man icon screen Drinted on housinq GC-VM White None Clear Selectable 15, 30, 75, or 95 cd 1.8 lb. (0.82 kg.) White 'FIRE" GCFR-VM Red 'FIRE" GC-VMH White None Selectable high output 95,115,150, or177cd GCF-VMH White "FIRE" ECS/MNS Aøoliances (no runnina man icon on housino GCWA-VMA White "Alert" Amber Selectable A, B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA "Alert" Amber Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. ' ) fit EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane, NC 27302 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 4 of 4 DATA DATA SHEET 85001-0557 Not to be used for installation purposes. Issue 7 0 0 F') C') EST Catalog I> Strobes, Horns, Bells, Chimes * _ Life Safety & Communications Field Configurable Horns and Strobes ECS/MNS appliances available with clear or amber lenses. A A - ALERT' '1 IT 7125i657 JZA 0284 FCE 1s5389I lS297ol MEA S Overview The Genesis line of fire alarm and mass notification/emergency communications (ECS/MNS) signals are among the smallest, most compact audible-visible life safety signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - EullLight technology. FuilLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular re- flectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FuilLight technology go well beyond the UL-1 971 and ULC-S526 light distribution requirements. Genesis strobes and horn-strobes offer selectable candela output by means of a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unauthorized tampering. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between fire alarm and mass notification alerts. Standard Features Unique low-profile design — The most compact UL-1971/ULC-5526 listed strobe available — Ultra-slim — protrudes less than one inch — Attractive appearance — No visible mounting screws Four field-configurable options in one device — Select 15, 30, 75, or 110 cd strobe output — Select high (default) or low dB horn output — Select temporal (default) or steady horn output — Select public mode flash rate (default) or private mode temporal flash Fixed 15/75 cd model available a ECS/MNS models available Easy to install — Fits standard 1-gang electrical boxes — no trim plate needed — Optional trim plate accommodates oversized openings — Pre-assembled with captive hardware — #12 AWG terminals — ideal for long runs or existing wiring a Unparalleled performance — Industry's most even light distribution — Meets tough synchronizing standards for strobes — Single microprocessor controls both horn and strobe — Independent horn control over a single pair of wires — Highly regulated in-rush current — Multiple frequency tone improves sound penetration — Field-programmable temporal strobe output option Page 1 of 6 DATA SHEET 85001-0573 Not to be used for installation purposes. Issue 11.1 Application Genesis strobes are UL 1971-listed for use indoors as wall-mount- 0 ed public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required, Horns Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Horn-only models may be ceiling-mounted or wall-mounted. The suggested sound pressure level for each signaling zone used with arm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. ECS/MNS Applications Genesis ECS/MNS strobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications. Available with amber lenses and optional ALERT housing labels, they are ideal for applications that require differentiation between fire alarm and mass notification alerts. Installation Genesis horns and strobes mount to any standard one-gang sur- face or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four-inch square, or octagonal boxes, and European 100 mm square. All Genesis signals come pre-assembled with captive mounting screws for easy in- stallation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Field Configuration Genesis Horn/Strobe Temporal horn and horn-strobe models with optional trim plate are factory set to sound in a three-pulse temporal pattern. Units may be con- figured for use with coded systems by cutting a jumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required when horn- strobe models are configured for coded systems. Non-temporal, horn-only models sound a steady tone. Genesis clear strobes and horn-strobes are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting a jumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis clear strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output. The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. Polarity shown in alarm condition To next appliance, end-of-line or return to control equipment 101 Note: Strobes must have continuous voltage. S Page 2 of 6 DATA SHEET 85001-0573 Not to be used for installa tion purposes. Issue 11.1 Horns Wall or Ceiling Mounted Temporal Horns (G1-HD) UL Rating High dB (RMS) Low dB (RMS) 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16 Vfwr 51 37 24 Vfwr 69 52 33 Vfwr 1 76 1 70 Typical Current High dB Low dB RMS RMS 16 Vdc 22 17 20 Vdc 24 19 24 Vdc 27 22 33 Vdc 32 26 16 Vfwr 34 30 20 Vfwr - 40 34 24 Vfwr 45 38 33 Vfwr 52 47 Wall or Ceilinci Mounted Horns (G1-P UL Designation Voltage Range I I Max. Current, RMS Regulated 24 16-33Vdc I I 13mA Vdc I 24 fwr 16 - 33 Vfwr 11 mA Typical Current RMS 24 Vdc 10 24 Vdc 11 31 Vdc 12 20 Vfwr 9 24 Vfwr 10 Current values are shown in mA. S C Current Draw Strobes, Horn-Strobes s(61-VM UL 15 cd* 30 cd* 15/75 cd** 75 cd* 110 cd* Rating RMS RMS RMS RMS RMS 16 Vdc 103 141 152 255 311 16 Vfwr 125 179 224 346 392 '(31 -VM multi-cd; 61 l--V1575 fixed 15/ (5 cd Typical 30 cd 15/75 75 cd 110 cd Current RMS RMS RMS RMS RMS 16 Vdc 85 127 150 245 285 20 Vdc 71 98 123 188 240 09" 82 104 152 191 33 Vdc 46 64 84 112 1 137 16 Vfwr 119 169 223 332 376 20 Vfwr 103 143 189 253 331 24 Vfwr 94 129 169 218 262 33 Vfwr 87 112 148 179 205 al Horn- WhAftecum :*(31FHDv1575ft<ed 15/75 cd 15 15 30 15/75 75 110 UL cd* cd** cd* cd* Rating RMS RMS RMS RMS RMS 16 Vdc 129 167 172 281 337 16 Vfwr 176 230 269 397 443 Typical 15 cd 15/75 75 cd Current RMS RMS RMS RMS RMS 16 Vdc 102 135 160 246 309 - 20 Vdc 88 109 137 193 248 81 122 161 ________ 33 Vdc 74 72 106 124 154 16 Vfwr 144 182 247 352 393 20 Vfwr 141 162 220 274 362 24 Vfwr 136 152 203 235 282 33 Vfwr 125 144 196 201 232 Wall Temporal Horn-strobes - Low dB Setting 15 I 30 15/75 75 110 ULL cd I I cd* cd** cd* cd* Rating RMS RMS RMS RMS RMS 16 Vdc 122 160 146 274 330 16 Vfwr 162 216 231 383 429 *G1HDVM multi-cd **G1FHD\/1575 fixed 15/75 cd Typical 15 cd 30 cd 15/75 75 cd 110 cd Current RMS RMS RMS RMS RMS 16 Vdc 96 130 158 243 302 20 Vdc 79 104 133 189 241 24 Vdc 68 88 119 156 197 33 Vdc 56 71 100 118 146 16 Vfwr 128 180 241 344 389 20 Vfwr 118 157 213 266 343 24 Vfwr 113 144 195 230 279 33 Vfwr 112 137 182 197 226 Page 3 of 6 DATA SHEET 85001-0573 Not to be used for installation Purposes. Issue 11.1 dBA output Temporal Horns, Horn-strobes (G1-HD, G1-HDVM series) High UL464 Average Peak dB Setting Temporal I Steady Temporal/ Steady Temporal! Steady 16 Vdc 81.4 I 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 1 96.9 1 99.5 Low dB UL464 Peak Setting Temporal Steady Temporal! Steady 16 Vdc 76.0 80.1 89.2 T925 24 Vdc 79.4 83.5 92.5 33 Vdc 82.1 j 86.5 95.3 Steady Tone Horns (Gi -P series) UL464 Average Peak 16 Vdc 77 dBA, min 85 dBA 91 dBA 16 Vfwr 77 dBA, min 85 dBA 91 dBA Notes All values shown are dBA measured at 10 feet (3.01m). UL464 values measured in reverberant room. Average and Peak values are measured in anechoic chamber. Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at lOft) Light output - (effective cd) Percent of UL rating versus angle especifications Housing Red or white textured UV stabilized color impregnated engineered plastic Exceeds 94V-0 UL flammability rating - Lens Strobes and horn-strobes are for wall-mount installation only. Horn-only models may be ceiling- or wall-mounted. Mounting Flush mount: 21/2 inch (64 mm) deep one-gang box (indoor only) Surface mount: Model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor only: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Agency listings/approvals UL 1971 (S218), UL 1638 (S218), UL 464 (S218), ULC S525, ULC S526 CSFM, CE, FCC, MEA. (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions (HxWxD) Signal: 4-1/2" x 2-3/4" x 13/16" (113 mm x 68 mm x 21 mm) Trimplate: 5" (127 mm); Height - 5-7/8" (149 mm); Depth - ½" (13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional G1 M Genesis Signal Master) G1-VM series strobes: non-coded, filtered 16 - 33 Vdc or unfiltered 16-33 Vdc FWR G1-P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe output rating UL 1971: 15 cd (fixed 15/75 cd models) UL 1638, ULCS526: 75 cd (fixed 15/75 cd models) Gi -VM strobes and Gi -HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Strobe flash rate Gi M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of horns on same circuit SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SlGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1OA, APS6A, APS1OA, i064, 0500, Fireshield Plus 3, 5 and 10 zone. Add G1 M for G1-CVM &G1 -HDVM devices only. Horn pulse rate P a G1-HD temporal-tone horns and G1-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely within 10 milliseconds. G1-P steady-tone horns: continuous, steady tone only Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 1½ sec OFF, then repeat cycle Page 4 of 6 DATA SHEET 85001-0573 Not to be used or installation purposes. Issue 11.1 Candela Output Switch Switch Switch Switch Rating Position is Lens Color Position A Position Position B C 0 Amber UL 1638 110 cd 75 cd 30 cd 15 cd Amber UL1971* 88 cd 60 cd 24 cd 12 cd Clear UL 1971 110 cd 75 cd 30 cd 15 cd Equivalent Rating Ordering Information Model I Housing I Marking I Lens I Strobe Fire Alarm Appliances (c/w runninq man icon screen irinted on housinci) Fire appliances available with white or red housings. zi_ J H 7. ECS/MNS appliances available with clear or amber lenses. A 1A I LI FL ELJE J ALERT j ( ALERT JJ Horn I Ship Wt. lbs (kg) G1-VM White I None Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) Gi F-HO White FIRE Clear Horn only Selectable high/low dB 0,25 (0.11) G F-H0V1575 White FIRE Clear 15/75 Cd1 Temporal hi/la dB-24V 0.25 (0.11) White FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1 F-P White FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1F-V1575 White FIRE Clear 15/75cd1 Strobe only 0.25 (0.11) White FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1-HD White None Clear Horn only Selectable high/low dB 0.25 (0.11) G1-HDVM White None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1-P White None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1RF-HD Red FIRE Clear Horn only Selectable high/low dB 0.25 (0.11) G1 RF-HDV1575 Red FIRE Clear 15/75 cd1 Temporal hi/lo dB-24V 0.25 (0.11) G1 RF-HDVM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1RF-P Red FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1RF-V1575 Red FIRE Clear 15/75cd1 Strobe only 0.25 (0.11) GI RF-VM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1R-HD Red None Clear Horn only Selectable high/low dB 0.25 (0.11) Gi R-HDVM Red None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1 R-P Red None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1 R-VM Red None Clear Selectable 15, 30, 75, or 110 cd [Strobe only 0.25 (0.11) ECS/MNS Anoliances (no ninnina man icon on housinall G1WA-VMA White ALERT Amber Selectable A, B, C or D Strobe only 0.25 (0.11) Gi WA-VMC White ALERT Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1WN-VMA White None Amber Selectable A, B, C or D Strobe only 0.25 (0.11) G1WN-VMC White None Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) Trim Plate G1T White None Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) G1 FIT Red None Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) Gi T-FIRE White FIRE Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) Gi RT-FIRE Red FIRE Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) G1 WI-ALERT White ALERT Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) Surface Boxes 27193-16 White N/A One-gang surface mount box 1(0.4) 27193-11 Red N/A One-gang surface mount box 1(0.4) I These 15/75 cd models provide fixed output and are not multi-candela devices. The 15 cd output component complies with UL1971, while the 75 cd output component complies with UL 1638. I Page 5 of 6 DATA SHEET 85001-0573 Not to be used for installation purposes. Issue 11.1 S Contact us... Email: edwards.fire©fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane, NC 27302 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. S I Page 6 of 6 DATA SHEET 85001-0573 Not to be used for installation purposes. Issue 11.1 Life Safety & Communications EST Cataloq Strobes, Horns, Bells, Chimes Field Configurable . One or more patents pending. Ceiling Horn _Q+rk L)LIJUO Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6(41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FuliLight technology. FuilLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FuliLight technology go well beyond the minimum UL-required 'cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. MEA CE 7300-1657: 0202 S218 Standard Features Field configurable no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 Cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - 418 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FulILight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page 1 of 4 DATA SHEET 85001-0559 Not to be used for installation purposes. Issue 9.2 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or .wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. Edwards recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. . Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour peod. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions 6.8' dia. (173 mm) ) O 1.0" (25 mm) 0.60(15 mm Page 2 of 4 Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Edwards recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. 31 Polarity: alarm c next liance, t-of-line eturn to ontrol Jipment Note: Strobes must have Continuous voltage. DATA SHEET 85001-0559 Not to be used for installation purposes. Issue 9.2 Light output - (effective Cd) Percent of UL rating versus angle 0 S Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting UL 15 c 30 c 75 c 95 c Rating RMS RMS RMS RMS 16 Vdc 147 190 316 372 16Vfwr 189 253 417 451 Typical 1d 75 Cd Current RMS Mji, RMS hjnft RMS Mean RMS Mesq- 16 111 95 152 143 281 276 333 328 20 Vdc 91 80 124 117 219 214 257 251 (29&dc, 80 108 185 180 212 33 Vdc 69 62 89 84 144 140 160 156 16Vfwr 153 81 218 123 388 240 420 268 20Vfwr 141 70 190 100 325 188 378 219 24Vfwr 135 64 176 90 280 154 310 180 33Vfwr 139 61 167 80 241 122 254 133 GC-HDVM Temporal Horn-strobe: Low dB Setting Typical 15 c 30 c 75 c 95 c Current RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 20 Vdc 87 75 120 113 214 209 250 245 24 Vdc 76 66 103 97 180 175 205 201 33 Vdc 64 57 85 80 138 135 153 150 16Vfwr 141 76 204 118 384 239 418 265 20Vfwr 127 65 176 95 312 181 371 214 24Vfwr 118 60 162 82 262 149 301 171 33Vfwr 127 56 155 73 229 118 249 129 GC-HDVMH High Cd Temporal Horn-strobe: High dB Setting 95 c 115 c 150 c 177 c RMS RMS RMS RMS 341 399 506 570 487 578 670 711 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 c 115 c 150 c 177 c RMS Mean RMS Mean RMS Mean RMS Mean 324 322 377 374 477 474 554 551 258 256 299 296 369 366 417 414 220 217 252 249 304 301 341 338 172 169 188 185 223 220 244 241 463 265 535 312 665 400 718 442 392 211 439 240 517 287 587 334 346 179 382 212 458 246 498 271 296 142 323 152 358 178 387 194 GC-HDVMH High ed Temporal Horn-strobe: Low dB Setting 95 c 115 Cd 150 c 177 Cd RMS Mean RMS Mean RMS Mean RMS Mean 317 315 378 376 480 477 544 542 252 250 292 290 364 362 414 411 212 211 245 243 297 295 334 332 159 157 181 179 215 213 234 232 461 265 521 305 656 396 705 432 381 208 437 242 508 285 576 326 335 172 370 195 440 235 485 264 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. Edwards recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used 'mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output UL464 Average Peak High dB Setting Temporal Steady Temporal! Steady Temporal! Steady Vdc —16 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 1 85 87.8 95.7 1 98.7 Low dB UL464 Average Peak Setting Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 80.9 85.9 91.8 95.1 Notes I. PJI values shown are dBA measured atlOfeet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 DATA SHEET 85001-0559 Not to be used for installation purposes. Issue 9.2 Specifications WA_I) Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available, Lens Optical grade polycarbonate (clear) Contact us ... Mounting North-American 4" square box, 2 1/8(54 mm) deep (indoor wall or ceiling applications only). Email: edwards.fire@fs.utc.com Web: www.est-fire.com Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size EST is an EDWARDS brand. Operating environment Indoor: 32-1 20°F (0-49°C) ambient temperature. 93% relative humidity 1016 Corporate Park Drive Meets or exceeds ULC-S525 & ULC-S526, year 2004 UL Mebane, NC 27302 Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies In Canada, contact Chubb Edwards... with UL1 480. All horn-strobes comply with ADA Code of Federal Email: inquiries@chubbedwards.com Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Web: www.chubbedwards.com GC-HDVM series temporal-tone horn-strobes: non-coded, filtered © 2013 UTC Fire & Security Americas Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc F\NR (or coded (audible NAG only) Corporation, Inc. All rights reserved, when used with optional Gi M Genesis Signal Master) Specifications subject to change Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- without notice. Edwards is part of UTC HDVM) and 95/115/150/177 cd (GC-HDVMH) Climate, Controls & Security, a unit of United Technologies Corporation. GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without GI M Genesis Signal S Master) Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, then repeat cycle Ordering Information Catalog Housing Ship Number Color Marking Description Wt. lbs (kg) GC-HDVM White None White FIRE' Genesis Ceiling/Wall Horn-Strobe with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red FIRE' (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories G1M-RM Genesis Signal Master— Remote Mount (1-gang) 0.2 (0.1) SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. Page 4 of 4 DATA SHEET 85001-0559 Not to be used for installation purposes. Issue9,2 EST Ct2ioq0,, Strobes, Horns, Bells, Chimes Life Safety & Communications Outdoor Rated Horns and Horn-Strobes Overview Genesis WG4 Series horns and horn-strobe appliances are among the most versatile emergency appliances of their kind. Rated for indoor or outdoor use, they are suitable for a wide range of wet and harsh environments with a listed operating temperature range of as low as -40 °F to as high as 151 °F (-40 °C to 66 00). Field-configurable light and sound output settings add to their on- site flexibility, while optional FIRE markings make them ideal for fire alarm applications. These appliances are suitable for indoor and outdoor applications, and are ideal for challenging conditions such as parking garages and process areas. They are available for mounting on the ceiling or the wall, and thanks to an ingenious optional full backplane sealing gasket, can be installed to recessed (in-the-pour/block) electrical boxes. WG4 notification appliances also mount to suit- able surface boxes. Optional color-matched trim skirts provide a clean, finished appearance. All appliance wiring is accomplished room-side for easy installation. WG4 Series appliances feature an efficient and powerful piezo sounder. The multi-candela strobes are available with clear lenses in two output categories - standard and high-output. They are precision-timed to meet UL 1971 synchronization standards, and field-configurable for one of four candela intensities. Candela settings are viewable even after installation through an innovative sealed viewport display. Standard Features Outdoor and indoor rated Low-profile design Wall or ceiling mount Room-side wiring accepts 18 to 12 AWG (0.75 to 2.5 mm2) Wide operating temperature range Field-selectable settings Fully-compatible with Genesis synchronization protocols Standard and high-output strobe intensities Horn only and horn-strobe options Page 1 of 4 DATA SHEET 85001-0628 Not to be used for installation purposes. Issue 2.2 Wire slot Application Horns The suggested sound pressure level for each notification zone used with alarm notification appliances is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is A-weighted (fast response) sound pressure measured over a 24-hour period. Doubling the distance from the notification appliance to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materi- als in the space. A 3 dBA difference represents a barely noticeable change in volume. Strobe Application Genesis clear-lensed strobes are UL 1971-listed for use indoors as wall- or ceiling-mounted public-mode notification appliances for the hearing impaired, and UL 1638-listed for outdoor applications. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public, accommodation. Visible appliance synchronization is required to avoid causing ssues with people who have Photosensitive Epilepsy (PSE). Noti- fication appliance synchronization is also generally required when more than two strobe appliances are in the same field of view from any one location. All Genesis strobes meet UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Edwards recommends that these devices always be installed in accordance with the latest recognized edition of national and local codes. Refer to the appropriate codes and standards for mounting height information. Page 2 of 4 Installation and Mounting WG4 Gasket Front 0 WG4 notification appliances are rated for outdoor use and are suitable for indoor or outdoor applications on walls or ceilings. For surface-mounting in outdoor or wet applications, appliances must be mounted to a 449 or 74347U electrical box. In dry conditions, they are compatible with standard 4-inch square by 11/2-inch deep electri- cal boxes. When using the optional WG4\NTS or WG4RTS trim skirt, a 449 or 4-inch square by 2-1/8" deep box must be used. The Genesis WG4 horn and horn-strobe may be wall- or ceiling- mounted, and may be placed in one of four positions: strobe above, strobe below, and strobe to either side. The shallow depth of Gen- esis devices leaves room behind the appliance for extra wiring. Horn volume jumper (JP3) pattern jumper (JP4) Horn output: Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5dB. Strobe pattern: Genesis WG4 horn-strobes are factory set for use as UL 1971 compliant notification appliances for public mode operation. These notification appliances may be configured for temporal flash by cutting JP4 on the circuit board. This battery-saving feature is intended for private mode signaling only. Strobe output: Genesis WG4 horn-strobes may be set for one of four out- put intensities.The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible after the cover is closed through a small window on the front of the device. DATA SHEET 85001-0628 Not to be used for installation Purposes. Issue 2.2 SGenesis horn output reaches as high as 97 dBA in accordance with UL 464 (104 dBA in accordance with ULC-S525) and features a unique frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded notification circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. al Field Configuration Horn pattern: Audible output for WG4 horns and horn-strobes is factory set to to sound in a three-pulse temporal pattern. Units may be configured for use with coded systems by cutting a JP1 on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the notification circuit. A Genesis Signal Master is required when horn-strobe models are con- figured for coded systems. Wiring Field wiring is connected to WG4 notification appliances with terminals that accommodate 4118 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Signal In - Cm--1 I - Signal Out - Signal .-i -•--• +6+.iui_A1i Q-e IN \.. I_y_y_ I 1( Light Output Angle Horizontal Plot -30 30 48 35 -40 40 -45 45 -55 50 -58 55 40 50 .05 05 -70 70 -75 75 -00 50 .05 85 .90 90 o 00009. 9.. 000 fl fl flfl !-!CflNe9fl Percentage of rated output Standard Candela Horn-strobes Standard/rating Strobe Switch Position t C B A -1+ designations indicate the signal polarity required to activate the device. Specifications Horns and Horn-strobes Operating voltage 24 VDC, 24 VFWR nominal Dimensions (iN x H x D) 5.6 x 8.5 x 1.4 in. (142 x 216 x 36 mm) Horn tone 3.2 kHz Wire size 12 to 18 AWG (0.75 to 2.50 mm2) Compatible electrical box Outdoor Model 449 or 74347U Indoor 4 in. square by 1.5 in. deep box Operating environment Temperature -40 to 151°F (-40 to 66°C) Relative humidity 0 to 95% noncondensing Compatible Synchronization Sources Horn-strobes Auto-sync Output Modules SIGA-CC1S, SIGA-CC2A, SIGA- MCC1S, SlGA-MCC2A Genesis Signal Master Gi M-RM Booster & Auxiliary Power Supplies APS6A, APS1 OA, BPS6A, BPS1 OA Control Panels with Genesis FireShield Plus, iO Series, EST3X Synchronization built-in Sound Output Horns and Horn-strobes (dBA) Volume Setting 16V 24V 33V UL 464 ULC- S525 UL 464 ULC- S525 UL 464 ULC- S525 Continuous High 89.7 94.0 94.7 99 97.4 102.9 Continuous Low 85.4 92.8 85 97.2 92.5 98.6 Temporal High 84.2 96.5 as 100.5 93.5 104.2 Temporal Low 81.7 90.3 85.4 94.2 8-8-71-1 97.0 cIBA = Decibels, A-weighted. UL 464: Sound level output measured in a reverberant room at 10 ft. (3.05m). CAN/ULC-S525: Sound level output measured in an anechoic room at lOft (3.05m). Page 3 of 4 UL 1971 tlr 1ek 29 cd 70 cd 87 cd UL 1638 Outdoor @-35°C 6 c 12 cd 28 cd 35 cd CAN/ULC-5526 Outdoor @ -40°C 1 cd 3 cd 8 cd 10 cd High Candela Horn-strobes Standard/rating Strobe Switch Position D C B A UL 1971 Indoor 102cd 123cd 147cd 161cd UL 1638 Outdoor @-35°C 41cd 50 cd 60 cd 65 cd CAN/ULC-S526 Outdoor @ -40°C 11 cd 14 cd 17 cd 18 cd Operating Current (UL specifies current ratings at 16 volts) Standard Candela Horn-strobes in RMS (mA), continuous Strobe Switch Position Input Voltage C B A 16 VDC 127 168 297 351 16 VFWR 218 239 393 422 VW1W6=' V-2111 130 210 238 24 VFWR 190 222 325 356 High Candela Horn-strobes in RMS (mA), continuous Strobe Switch Position Input Voltage D C B A 16 VDC 342 408 517 526 16 VFWR 447 502 614 679 24 VDC 240 271 327 365 24 VFWR 390 400 486 540 Horn only models (mA) 16V RMS, continuous 24V, typical Setting High dB Low dB High dB Low dB VDC 69.1 41.2 49.0 32.3 VFWR 135 91.3 99.1 67.1 DATA SHEET 85001 -0628 Not to be used for installation purposes. Issue 2.2 Ordering Information EDWARDS Contact us... U U Email: edwards.fire@fs.utc.com Web: wwwest-fire.com W64RF-H WG4RF-HVMC WG4WF-H WC4WF-HVMC WG4RN-H WC4RN-HVMC W64WN-H WG4WNHVMC Model Housing Marking Strobe Output Ship Wt. WG4RF-HVMC Red FIRE Selectable standard candela output WS.FLVMC- White WG4RN-HVMC Red None WG4WN-HVMC White WG4RF-HVMHC Red FIRE Selectable high candela output 1.5 lbs. (0.68 kg) WG4WF-HVMHC White WG4RN-HVMHC Red None WG4WN-HVMHC White WG4RF-H Red FIRE Horn Only WG4WF-H White WG4RN-H Red None WG4WN-H White EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane, NC 27302 In Canada, contact Chubb Edwards.,. Email: inquiries@chubbedwards.com Web: wwwchubbedwardscom © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Accessories WG4WTS Surface Skirt for Genesis WG4 appliance family, white, WG4RTS Surface Skirt for Genesis WG4 appliance family, red. WG4GSKT Full Body Mounting Gasket for smooth surfaces, WG4 appliance family 74347U Surface mount box, outdoor rated, red 449 Surface mount box, outdoor rated, gray Page 4 of 4 DAT A SHEET 85001-0628 Not to be used for installation purposes. Issue 2.2 M.I=l I oil: _IFIiR![c fl C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ..... OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 77:0-' Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/Ml SC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models SlGA-CC1, SIGA-CC2, J!SlGA-CT1HT, SlGA-CT2, SIGA-CR, SlGA-CRR, SlGA-UM, SIGA-MM1, SlGA-wrM, SIGA-IM, SlGA-MDM, SIGA-MAB, SlGA-MCT2, SIGA-MCC1, SIGA-MCC2, SIGA-MCR and SlGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MP1 SlGA-MP2 and SlGA-MP2L mounting plates. Models SIGA-U102R, SIGA-UlO6 and SlGA-UI06R motherboards. Model CS-SIGA-CCI P releasing module. Models SIGA-CC1S and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. *Model SIGA-CT1HT; Signature Series High Temperature Single Input Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 03-10-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 011 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models GC-VM, MGCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model GIM-RM (CSFM Listing No. 7300-1657:201)sync module, which may employ Model SlGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. 5 APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEG!AN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 31 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models G1-VM, G1R-VM, FVMG1RF-VM, GI41575, G11341575, G1F-V1575, G1RF-V1575, G1WA-VMC and G1WN-VMC synchronizable type strobe lights. The suffix R refers to red and W refers to white color enclosure; the suffix F refers to the word "FIRE" refers to a silk-screened word FIRE" on the strobe housing; the A in the model number indicates (Alert) marking; N in the model indicates no marking. Intended for indoor and mounted on a wall only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 V dcNFWR Candela G1-VM and G1W-VMC series 15cd, 30cd, 60cd, 75cd, 110cd Selectable G1-V1575 series 15/75cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances • and MARKING: in a manner acceptable to the authority having jurisdiction. Listee's UL label. name, model number, electrical/candela rating, and APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Units are synchronizable when used with Models G1 or G1M-RM sync module (CSFM Listing No. 7300-1657:201) which may employ Models SIGA-CC1S or SIGA-MCC1S Auto-Sync output modules as an accessory (CSFM Listing No. 7300-1657:121). For indoor use and wall mount only. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:218 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S v operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models "EST' GI-HVI5, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -H0V75, -HOVI10, GlF-HOVI5, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-H0V15, -HOV30, -HOV60, -H0V75, -HOV1I0, G1-HDVM, G 1 R-HDVM,GI VM G1 RF-HDVM, GC-HDVM, GC-HDVMH, GFTRVM, GCFR-HDVM, GCF-HDVMH, GI-HDV1575, Gi R-HDV1575, GIF-HDV1575, and GIRF-HDV1575 horn/strobes with or without suffixes -Rand -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 Vdc/Vfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, GI-HDV1575, G1 R-HDV1575, G1 F-HDV1575, GI RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM • 95-177 multi-cd-Models GC-HDVM H, GCF-HDVMH 15/75cd -Models GI-HDV1575, GI R-HDV1575, Gi F-HDV1575, Gi RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *CF..HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 11 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models WG4RF-HVMC, WG4RN-HVMC, WG4RF-HVM HC, WG4RN-HVMHC, WG4WF-HVMHC, and WG4WN-HVM HC horn/strobe. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC regulated or 16-33Vdc 24 Fwr regulated or 16-33 Vfwr INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an wall/ceiling mount horn/strobe for use with separately listed compatible fire alarm control units. Units are approved for indoor or outdoor applications. Refer to manufacturer's Installation Manual for details. 05-21-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 11 Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division S I