Loading...
HomeMy WebLinkAbout7740 EL CAMINO REAL; ; FS050015; PermitCity of Carlsbad Fixed Systems Permit Permit No: FS050015 7740 EL CAM INO Job Address: REAL Permit Type: FIXSYS Parcel No: Status: APPROVED Applied 9/22/2005 Approved: 9/29/2005 Reference No.: Issued: 9/29/2005 Inspector: Project Title: RED DAHLIA HOOD & DUCT PLAN CHECK & INSPECTIONS Applicant: Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) 120 0 120 0 4- CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, cendEtions in correspondence and conformance with applicable regulations. The stamping Of thes Ian all not be held to permit or ap v violation of any law By Date1/1ZJ ØO O( b3/O INTERSTATE FIRE PROTECTION SYSTEM DETAIL ITEM DESCRIPTION SIZE DETAILS IDIMENSIONS NOZZLES QTY FLOW HOOD 10'x6' I MEREX KP3.75 X 2 375 GAL 11 MAX 2 DUCT NOZZLE 12" X 18" 0" PER/ 82" MAX 16416 2 - 2 3 PLENUM NOZZLE 10' SINGLE-BANK 11982 1 1 4 GAS RAIDIANT CHAR BROILER 24" X 24" 11982 1 1 5 RANGE NOZZLE %" X 24" VITH BACK SHELF 11982 3 3 6 DEEP FRYER NOZZLE 15" X 19" 13729 1 2 7 GRIDDLE NOZZLE 24" X 24" 11982 1 .1 8 SALAMANDER 30" X 12" 11982 1 1 9 9 10 LIQUID TIGHT SEAL UL RATED 6 TOTAL FLOW PTS. USED 10 11 12 LINK DETECTOR I50de.. 13 PULL STATION 18" OFF FLOOR I 14 GAS SHUT OFF VALVE 1.5" MCHANICAL I 15 FIRE EXTINGUISHER K-MODEL I 16 IFIRE EXTINGUISHER A:10BC I RED DAHLIA 11 l -n - m Cl) °rn I— z Cl) BEVERAGE STATION FRONT SERVICE COUNTER PA r_ [M1 N\1 l/l fl - 7 SYSTEM INSTALLED TO NFPA 17A, 96 AND THE MANUFACTURES LISTED INSTALLATION MANUAL ALL FUEL SOURCES WILL SHUTDOWN UPON HANGERS SHALL BE 0 MINERALACS ACTIVATION. SUPPLY LINE 12' SCH. 4° EXPOSED PIPE SHALL BE CHROME PLATED. SYSTEM WILL TIE INTO ALARM SYSTEM IF ONE BRANCH LINE 3/8' SCH. 40 PIPING SHALL BE RIGIDLY SUPPORTED TO EXISTS. SCALE:1\2' = V PREVENT MOVEMENT. JOB SITE RED DAHLIA 7740 EL CAMINO REAL STE.F CARLSBAD, CA SHAWN 760 580-3549 HOOD AND DUCT AMEREX KIP FIRE SUPPRESSION SYSTEM HOOD DETAIL INTERSTATE FIRE PROTECTION 36140 JANA LANE WILDOMAR, CA 92595 (800) 282-9229 FAX (951) 461-6980 Design / install/ employee Steve Nauert Lic. C16-747953 0 tY31SX 1 it F I FP LA'(ZO 13,1 ?-q 2-1:*p 9 L.~ T viz )Y If I re 3Ff' 3"4 SYSTEM INSTALLED TO NFPA 17A, 96 AND THE MANUFACTURES LISTED INSTALLATION MANUAL ALL FUEL SOURCES WILL SHUTDOWN UPON HANGERS SHALL BE 0 MINERALACS ACTIVATION. SUPPLY LINE 1\2' SCH. EXPOSED PIPE SHALL BE CHROME PLATED. SYSTEM WILL TIE INTO ALARM SYSTEM IF ONE BRANCH LINE 3/80 SCH. 40 PIPING SHALL BE RIGIDLY SUPPORTED TO EXISTS. SCALE:1\2' = V PREVENT MOVEMENT. JOB SITE RED DAHLIA 7740 EL CAMINO 'REAL STE.F CARLSBAD, CA SHAWN 760 580-3549 HOOD AND DUCT AMEREX KP FIRE SUPPRESSION SYSTEM ISOMETRIC PIPE DETAIL INTERSTATE FIRE PROTECTION 36140 JANA LANE WILDOMAR, CA 92595 (800) 282-9229 FAX (951) 461-6980 Design / install! employee Steve Nauert Lic. C16-747953 C3 Fire Department Notes When a fire alarm system is provided in the building, it shall be interconnected to the fire extinguishing system per 1998 NFPA hA. Section 3-2.1.5. All gas fueled, electrically powered and heat-producing equipment located under the hood shall shutdown when the extinguishing system activates. 1998 NFPA 17A Section 2-4.3.1. When its fire-extinguishing system discharges, all electrical outlets shall be turned off. Piping shall be rigidly supported to prevent movement. All discharge nozzles shall be provided with caps, covers, or other suitable protective devices. 1998 NFPA hA. Section 2-3.1.4. Installation shall comply with NFPA 96 & 17A. Hood and duct construction and installation shall be in accordance with the 2001 Uniform Mechanical Code and nationally recognized standard. These assemblies are subject to approval and inspection by the local Building Official and are not part of the Fire Authorities review process except as it relates to .the installation of the hood extinguishing system. 1998 NFPA 17A Section 1-2. All movable cooking equipment shall be provided with a means to ensure that it is correctly positioned in relation to the appliance discharge nozzle during cooking operations. (1998 NFPA hA Section 3-6.3.) Chemical fire extinguishing systems shall be tested prior to placing in service. Test shall be witnessed by OCFA Inspector. 1998 NFPA hA Section 1-2. When its fire-extinguishing system discharges, make-up air supplied internally to a hood shall be shut off. 1998 NFPA 96 Section 5-3. A hood exhaust fan(s) shall continue to operate after the extinguishing system has been activated, unless fan shutdown is required by a listed component of the ventilation system or by the design of the extinguishing system. 1998 NFPA 96 Section 52.3. JUN IJUL 2007 INTERSTATE FIRE PROTECTION 36140 Jana Lane Wildomai CA 9259 800=470=FIRE 2 1 3 1 4 1 5.617 8 1 91011121314 lIe 11711811912.01211221231241 2512612712812934 tte Of W 091m saw 4795•• INTERSTATE FIRE PRCICTIOhL 4~Q46 AL 13WOO6 000 ... JAN State Contractors License # 747953 Type C-16