Loading...
HomeMy WebLinkAbout1525 FARADAY AVE; 140; FPC2018-0119; Permit(L'Cityr of L_M~ Li's irk gi if iftI1itI Print Date: 04/20/2022 Permit No: FPC2018-0119 Job Address: 1525 FARADAY AVE, # 140, CARLSBAD, CA 92008-7373 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121302700 Track #: Applied: 04/23/2018 Valuation: $108,228.77 Lot #: Issued: 05/01/2018 Occupancy Group: Project #: Finaled Close Out: 02/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: NEWPORT NATIONAL CORP / GYL -SPRINKLER TI (13 HEADS) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTMES INC DARIEN MORAN 12316 OAK KNOLL RD, # STE A 12316 OAK KNOLL RD POWAY, CA 92064-5363-SAN DIEGO P0 WAY, CA 92064-5363-SAN DIEGO (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov MATERIAL DATA SUBMITTAL Newport National Corporation GYL Suite - 140 Tenant Improvement 1525 Faraday Avenue, Suite #140 Carlsbad, CA 92008 FPC20I8-0119 1525 FARADAY AVE # 140 NEWPORT NATIONAL CORP /GYL - SPRINKLER TI (13 HEADS) 2121302700 412312018 FPC20I 8-0119 FIRE SYSTEMS INC. Pacific Fire Systems, Inc. 12316 Oak Knoll Road, Suite A Poway, CA 92064 858-883-2333 Phone 9 858-883-2334 Fax - —zJ FM Approved and Fully Listed Sprinkler Pipe Wheatland's WLS steel fire sprinkler pipe is hot-dip galvanized to meet FM requirements for dry systems and is UL, C-UL and FM Listed. Approvals and Specifications The product meets or exceeds the following standards: ASTM: A795, Type F, Grade A ANSI/ASME 131.20.1 pipe threads NFPA13 Manufacturing Protocols WLS is subjected to the toughest possible testing protocols to assure the highest tivality and long-lasting performance. Finishes and Coatings WLS is finished in black or hot-dip galvanized. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SPECIFICATIONS NPS NOM OD NOM ID UL CRR* WLS Schedule Schedule Schedule Nominal PCs./ PCs./ WLS 10 40 WLS 40 wt/ft Lift 21 Lift 25 1.315 1.087 N/A 1.049 .57 1.00 1.462 70 60 11/4 1.660 1.426 1.442 1.380 .46 1.00 1.928 55 45 11/2 1.900 1.650 1.682 1,610 .64 1.00 2.370 45 40 2 2.375 2,125 2.157 2.067 .52 1.00 3.004 35 30 'Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. & C& APPROVED S!tBM Iir.T1lir1EON PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK El HOT-DIP GALVANIZED hi'I.ID JIj '4 1tI$ J :{cXoAJF2 I I liMitii it Tube JMC STEEL GROUP Worldwide Contacts Series TY-FRB — 28,4.2,56, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. MARCH 2013 Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2"NPT 1Y1231: Pendent 2.8K, 1/2" NPT 4.2K, 1/2" NPT 4.2K, 1/2" NPT 5.6K, 1/2" NPT 5.6K, 1/2" NPT 8.0K, 3/4" NPT 8.0K, 3/4" NPT 8.0K, 1/2" NPT 8.0K, 1/2- NPT 'Eastern Hemisphere Sales Only TFPI7I 1Y2131: 1Y2231: 1Y3131: TY4131: TY4231: TY4831: TY4931: Upright Pendent Upright Pendent Upright Pendent Upright* Pendent* H— 2-7/8" (73,0 mm) DIA. - TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. ESCUTCHEON PLATE SEATING SURFACE 7/16" (11,1 mm) 1 NOMINAL 2-1/4 MAKE-IN (556 mm) (57,2 mm) I 2-3/16 1-9/16" (39,7 mm) 1/2 NPT** I WRENCH STYLE 10 0r20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing 11=. CROSS SECTION 2-7/8' (73,0 mm) DIA. -.- RECESSED PENDENT FIGURE 1 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE JNOMINAL ______________________ 7/16" 11,1 mm) 2-3/16"MAKE-IN (556 mmP(55,6 mm 2-3/16 _____ I 1/2' NPT** I WRENCH STYLE 10or20 FLATS RECESSED 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR 1/2 INCH NPT 1/2 NPT* 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. ESCUTCHEON PLATE SEATING SURFACE 7/16 11,1 mm) 2-3/16 OMINAL MAKE-IN (556 mm,// (55,6 mm) 1-1/2 2-3/16 (38,1 mm) WRENCH STYLE 10 or 20 FLATS RECESSED TFPI7I Page 3 of 10 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* 2-7/8" (73,0 mm) DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (7Y3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE UNOMINAL 1/2' (12,7 mm) 2-5/16 I (572 mn// (397 mm) MAKE-IN (58,7 mm) 2-1/4" 1-9/16' 3/4' NPT** WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT CEILING PLATE SEATING SURFACE nm) Vu PENDENT CROSS SECTION 1 - Frame 5 - Compression 2 - Button Screw 3 - Sealing 6 - Deflector * Assembly 4 - Bulb * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. Ll 7/16 1 (11,mm) NOMINAL MAKE-IN I it 2-3/16 (55,6 mn 1/2 NPT** I WRENCH FLATS UPRIGHT TFPI7I Page 4 of 10 FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS &O K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/barl/2) K=4.2 GPM/psi112 (60,5 LPM/bar1/2) K=5.6 GPM/psi112 (80,6 LPM/bar112) K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint shold be obtained by applying a min- imum to maximum torque of 7 to 14 ft.l-bs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer- ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprin- kler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY113I) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY1231)* Figure 6 135°F (57°C) Orange 1,2,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (1Y1231)** Figure 7 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY2231)* Figure 8 135°F (57°C) Orange 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY2231)** Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C) Orange 1,2,3,4,5,6,7 Blue 1,2,3,5 155°F (68°C) Red 175°F(79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)* Figure 10 135°F (57°C) Orange 1,2, 4, 5 N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY3231)** Figure 11 135° F (57°C) Orange 1, 2, 3, 4, 5 N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F(57°C) Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY4231)* Figure 12 135° F (57°C) Orange 1, 2, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C) Orange 1,2,3,5 Blue N/A 155°F (68°C) Red 175-F (79-C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C) Orange 1, 2,4,5, 6 Blue 1,2, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I SIGNAL LEAD FACTOR BRASS PLATED WHITE COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (1Y3231) N/A PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. TFPI7I Page 8 of 10 - 2-7/8 DIA. 5/8±1/4 - (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER _ PLATE FITTING 1/8 (3,2 mm) 4 '1 SURFACE CLOSURE SERIES 1-5/16" mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) I / FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE FITTING 1/8" / (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm)t TYFRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4 (6,4 mm) I FACE OF (57,2 mm) / -H i L I I MOUNTING SPRINKLER PLATE I FITTING 1/8" / (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12 7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING / (3,2 mm) MOUNTING 1 SURFACE SERIES 1-1/4"(31,8mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 9 of 10 2-7/8" DIA. (73,0 mm) I 3/4" (19,1 mm) 2-1/4" DIA. 1/4 (6,4 mm) (57,2 mm) MOUNTING ...- PLATE 1/8" r, rH (3,2 mm) _ 1-1/4" (31,8 mm) 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" - (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) /(57,2 mm) T FACE OF I i MOUNTING SPRINKLER L. -7) _- PLATE FITTING )- - (3,2 mm) MOUNTING / SURFACE/ ___ / CLOSURE SERIES 1-5/16" (33,3 mm)I TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. -. (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF - (57,2 mm) ! I I I MOUNTING I PLATE I I FITTING 1/8" I SPRINKLER (3,2 mm) I I \%!_ MOUNTING ,,,,///" ' SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) I (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE I FITTING 1/8" (3,2 mm) 1777 1 I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4 (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERI WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH 1 NATURAL BRASS PURE WHITE (RAL9O1O)° SIGNAL WHITE (RAL9003) 7 LEAD COATED 9 CHROME PLATED X JET BLACK (RAL9005) * Eastern Hemisphere sales only. ** Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. TFPI7I Page 10 of 10 PIN 57- XXX- X- XXX I I I I SPRINKLER I I SIN FINISH 330 2.8K UPRIGHT (1/2'NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2°NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (314"NPT) TY4231 360 8.OK UPRIGHT (1/2"NPT) TY4831° 361 8.0K PENDENT (1/2"NPT) TY4931° I TEMPERATURE _j•_ RATINGS 135 135°F(57°C) 155 155°F (68°C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) TABLED SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) finish or coating, P/N (Specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Refer to Technical Data Sheet TFP770. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. ?owers. FASTENERS PRODUCT INFORMATION VertigoTM Vertigo TM Rod Hangers Vertigo is an all steel threaded fastening system for suspending steel threaded rod vertically overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. Vertigo are available in three versions which can be installed in a variety of base materials including steel purlins, bar joists and beams, wood frame columns and beams, as well as concrete ceilings, beams and columns. Steel threaded rods in 1/4", 3/8" and 1/2" diameters can be vertically suspended with Vertigo. In wood and steel base materials, Vertigo is also offered in a side mount style for lateral installation of 1/4" and 3/8" diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood Vertigo fasteners, a universal Vertigo Socket Driver is recommended to provide proper installation with a screw gun or hammer drill. Concrete Vertigo fasteners should be installed with the appropriate size standard drive sockets and adjustable torque, battery powered screw gun or hammer drill. Hanging Pipe and Sprinkler Systems • Suspending Conduit and Cable Trays Lighting Systems and Overhead Utilities • HVAC Ductwork and Strut Channels Suspended Ceilings • Mounting Security Equipment SECTION CONTENTS Page No. General Information....................1 Installation Specifications............2 Material Specifications ...............2 Performance Data ........................3 Ordering Information..................7 Steel Vertigo Wood Vertigo + One system for all rod hanging applications in steel, wood and concrete + Ease and speed of overhead installation + Lower in-place cost, when compared to beam clamps, lag bolts and dropins + Steel and wood Vertigo can be installed with a screw gun or hammer drill + Concrete Vertigo can be installed with an adjustable torque, battery powered screw gun or hammer drill + Side mount versions available for steel and wood Vertigo + The universal socket can be used for the steel and wood Vertigo APPROVALS AND LISTINGS FM Approvals (FM) - (see listing for applicable sizes and types). Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 Underwriters Laboratory (UL) - (see listing for applicable sizes and types). Pipe Hangers - File No. EX 1289 Luminaire - File No. E362339 CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 19 - Post-Installed Concrete Anchors, 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Vertigo anchors as supplied by Powers Fasteners, Inc., Brewster, NY. ncrete Verti dJ edge-Bolt OT) ANCHOR MATERIALS Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYP.) 1/4" to 1/2" for Steel 1/4" to 1/2" for Wood 1/4" to 1/2" for Concrete SUITABLE BASE MATERIALS Steel Purlins and Beams Wood and Timber Normal-Weight concrete Structural Lightweight concrete Hollow Core Concrete Plank Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 1 -Powers VertigoTM PRODUCT INFORMATION FASTENERS Steel Vertigo Point Style #3 #5 Self Drilling Range 0.036" (20 gaue) - 0.188" (3/16') 0.188" (3/16") - 0.500" (1/2") Screw Size (UNC) 1/4-20 thread 1/4-20 thread Root Diameter (in.) 13/64 13/64 Thread Length (in.) 1-3/16" (1-1/2"screw) 31/32" (1-1/2"screw) Flange Thickness (in.) 1/16 1/16 Drill Speed (RPM) 500-1,500 500-1,500 Install with universal steel and wood socket. Wood Vertigo Screw Size 1/4" Thread Forming 5/16" Thread Forming Pre-drill Diameter (in.) (if required) 1/8 1/8 Point Style Type 17 Type 17 Root Diameter (in.) 3/16 7/32 Thread Length (in.) Screw length less 5/16 Screw length less 5/16 Flange Thickness (in.) 1/16 1/16 Install with universal steel and wood socket. Vertigo Couplings (Steel & Wood) Screw Size 1/4" 3/8" 1/2" 1/4" 3/8" Coupling Size and Type Vertical Vertical Vertical Side Side Thread Size (UNC) 1/4-20 3/8-16 1/2-13 1/4-20 3/8-16 Thread Depth (in.) 3/8 3/8 3/8 (through) (through) Width (flat to flat) (in.) 5/8 5/8 5/8 5/8 5/8 Height (in.) 13/16 13/16 13/16 13/16 13/16 Concrete Vertigo (Wedge-Bolt OT) Rod Diameter/Anchor Size 1/4" 3/8" 1/2" ANSI Drill Bit (in.) 1/4 1/4 3/8 Overall Screw Shank Length 1-1/4 1-1/2 2-3/4 Anchor Thread Length (in.) 1-1/8 1-3/8 2-1/2 Root Diameter (in.) 15/64 15/64 23/64 Coupling /Washer Height (in.) 27/64 9/16 53/64 Integral Washer O.D. (in.) 31/64 39/64 31/32 Coupling Thread Size (UNC) 1/4-20 3/8-16 1/2-13 Coupling Thread Depth (in.) 3/8 1/2 3/4 Socket Driver Size (in.) 3/8 1/2 11/16 Install with universal steel and wood socket. Installation Guidelines When installing Vertigo fasteners, eye protection ' ' •:. .' ' shoulI be worn as a . safety precaution. ,A ,A ' If pre-drilling is required (certain types of wood truss/wood joist and all concrete base materials), select the recommended drill bit type and diameter. For Concrete Vertigo only, drill to the appropriate embedment depth, adding at least one diameter (1/4" to 112") to the drilling depth to prevent the tip of the fastener from running into a dead end at the rear of the anchor hole. Concrete Select the appropriate socket driver for the anchor size and type to be installed and mount into 'e •, e• . . chuck of installation tool. Insert the Vertigo fastener into the socket driver, and install perpendicular to the base material surface. Drive the fastener with a smooth steady motion until the coupling is firmly seated against the surface of the base material. Thread the appropriate Steel diameter steel threaded 03 rod or threaded bolt into the coupling. The threaded rod or bolt should fully engage the thread length of the coupling on a vertical mount fastener. The threaded rod or 7 threaded portion of the bolt can pass through coupling of a side Wood mount fastener. For UL and FM listings for Pipe Hangers, Steel Vertigo should be installed with a retaining nut. Steel and Wood Vertigo Component Component Material Screw Body AISI 1018-1022 (Case Hardened) Coupling AISI 1018-1022 (Case Hardened) Zinc Plating ASTM B633, SC1,Type Ill (Fe/Zn5) Concrete Vertigo (Wedge-Bolt 01) Component Component Material Anchor Body Case Hardened 10821 Carbon Steel Zinc Plating ASTM B633, SC1,Type Ill (Fe/Zn 5) www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertigo - Ultimate Tension Load Capacities when Installed in Minimum ASTM A 36 Steel (Beams) and ASTM A 572 Steel (Purlins)1.2 Anchor Size / Minimum Steel Gauge (Thickness) 20 0.036" 18 0.048" 16 0.060" 14 0.075" 12 0.105" 3/16" 0.187" 1/4" 0.250" Rod Diameter in. Mount Direction Screw Shank Size and Length (mm) lbs. lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) (kN) Vertical 1/4-20 x 1" (w/nut) 1.550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) 1/4 Vertical 1/4-20 x 1 " 405 620 985 1,160 1,560 3,205 5,040 (6.4) (1.8) (2.8) (4.4) (5.2) (7.0) (14.4) (22.7) Side 1/4-20 x 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 - (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) Vertical 1/4-20 x 1" (w/nut) 11550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Side 1/4-20x1-1/2"(w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 3/8 Vertical 1/4-20 x 1-1/2" 405 620 985 1,160 1,560 3,205 (9.5) (1.8) (2.8) (4.4) (5.2) (7.0) (14,4) - Side 1/4-20 x 1-1/2" 405 620 985 1,160 1,560 1,965 (1.8) (2.8) (4.4) (5.2) (7.0) (8.8) - Vertical 1/4-20 x 2" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Vertical 12-20x 1-1/2 " 495 710 920 1,560 2,050 3,280 5,040 1/2 (2.20 (3.2) (4.1) (7.0) (9.2) (14.8) (22.7) (12.7) Vertical 12-20x1-1/2"(w/nut 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 1. For Steel Vertigo loaded perpendicular to threaded rod (shear) the ultimate load capacity for the anchor is 1,965 lbs in nominal 20 gage steel (0.036") Wood Vertigo - Ultimate Tension Load Capacities when Installed in Wood Base Materials (Structural Wood and Timber),,' Anchor Size / Embedment Depth Wood Member (Type) _______________________ Fir Pine Spruce Rod Diameter Mount Screw Shank Size in. Direction and Length in. (mm) lbs. lbs. lbs. (mm) (kN) (kN) (kN) 1/4 Vertical 1/4 x 1 1 (25.4) 685 (3.1) 650" 650 (2.9) (2.9) (6.4) Side 1/4x2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Vertical 1/4x1 1 (25.4) 685 (3.1) 650" 650 (2.9) (2.9) Side 1/4x 1" 1 (25.4) 685 (3.1) 650 (2.9) 650 (2.9) Vertical 1/4 x 2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Side 1/4x2" 2 1,800 1,800 1,800 3/8 (50.8) (8.1) (8.1) (8.1) (9.5) Vertical " 1/4 x 3 2,075 1,510 1,510 (76.2) (9.3) (6.8) (6.8) Vertical 1/4x4" 4 (101.6) 2,075 (9.3) 1,510 (6.8) 1,510 (6.8) Vertical 5/16" x2-112" 2-1/2 (63.5) 2,670 (12.0) 3,110 (14.0) 3,110 (14.0) Side 3/8" x2-112" 2-1/2 (63.5) 1,450 (6.5) 1,530 (6.9) 1,380 (6.2) 1/2 (12.7) Vertical 5/16" x2-1/2" 2-1/2 (63.5) 2,670 (12.0) 3,110 (14.0) 3,110 (14.0) Truss/joist manufacturers may require pre-drilled holes with wood depending on the location of the anchor installation. Consult with the truss/joist manufacturer for details. Wood Vertigo are recommended to be installed with the Universal Steel & Wood Nut Driver. Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com ?owers VertigoTM PRODUCT INFORMATION FASTENERS Concrete Vertigo - Ultimate Load Capacities when Installed in Normal-Weight Concrete'-' Anchor Size / ANSI Drill Bit Embed. Depth Minimum Concrete Compressive Strength (f c) 2,000 psi (13.8 MPa) 4,000 psi (20.7 MPa) 6,000 psi (41.4 MPa) Rod Diameter Mount Screw Shank Size Diameter It, Tension Shear Tension Shear Tension Shear Direction and Length dbit in. (mm) in. (mm) lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) 1/4 Vertical 1 /4"x 1-1/4" 1/4' 1-1/4 1,390 1,810 1,950 2,440 2,070 2,570 (6.4) (31.8) (6.3) (8.1) (8.8) (11.0) (9.3) (11.6) 3/8 Vertical 1/4"x 1-1/2" 1/4" 1-1/2 1,760 2,580 2,595 2,640 2,770 2,700 (9.5) (38.1) (7.9) (11.6) (11.7) (11.9) (12.5) (12.2) 1/2 Vertical 3/8"x2-3/4" 3/8" 2-3/4 5,320 5,250 6,050 6,330 8,620 7,410 (69.9) (23.9) (23.6) (27.2) (28.5) (38.8) (33.0) The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Linear interpolation may be used to determine ultimate loads for intermediate compressive strengths. Concrete Vertigo - Ultimate Load Capacities when Installed Through Metal Deck into Structural Lightweight Concrete"-'," Lightweight Concrete Over Minimum 20 Ga. Metal Deck Anchor Size! Embedment Depth f'c ~ 3,000 psi (20.7 MPa) Minimum 4 1/2" Wide Deck Rod Diameter h d in. Tension Load at 450 in. (mm) (mm) lbs. lbs. (kN) (kN) 1/4 1-1/4 800 1,140 (6.4) (31.8) (3.6) (5.1) 3/8 1-1/2 1,780 1,500 (9.5) (38.1) (8.0) (6.8) 1/2 2-3/4 3,880 2,920 (12.7) (69.9) (17.5) (13.1) The values listed above are ultimate and allowable load capacities for Vertigo rod hangers installed in sand-lightweight concrete. The metal deck shall be minimum No, 20 gauge thick steel [0.035-inch base metal thickness (0.89 mm)[ conforming to ASTM A 653/ A 653M. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. The tabulated load values are for anchors installed with a minimum flute edge distance of 1-1/2-inch. Concrete Vertigo - Ultimate Tension Load Capacities when Installed in Hollow Core Concrete Plank',' Anchor Size / Rod Diameter ANSI Drill Bit Diameter Embedment Depth Center of Web Center of Core Mount Screw Shank Size h, lbs. lbs. in. Direction and Length db r1. (kN) (kN) (mm) in. (mm) 1/4 (6.4) Vertical 1/4"x1-1/4" 1/4" 1-1/4 2,775 (12.3) 1,920 (31.8) (8.5) 3/8 Vertical 1/4"x1-1/2 (9.5) 1/4" 1-1/2 (38.1) 2,570" 3,700 (16.5) (11.4) 1/2 (12.7) Vertical 3/8"x2-3/4" 3/8" 2-3/4 8,240 (36.7) 3,480 (69.9) (15.5) Tabulated load values are for anchors installed in 8-inch-thick hollow core plank with minimum compressive strength of 5,000 psi at the time of installation. The 4'x 6' normal-weight concrete members features include 1-1/2" cover above and below cores and a minimum web thickness of 1-1/2". The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) listings for Pipe Hangers' Anchor Size / Maximum U L Minimum FM Minimum Rod Diameter Mount Screw Shank Pipe Size Steel UL Test Load Steel FM Test Load Cat. No. in. Direction Size and Point Style Thickness lbs. Thickness lbs. (mm) Length in. (mm) in. (kN) in. (kN) (mm) (mm) 7158 Vertical 1/4-20x 1 " 4 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1,500 0.096 1,475 7184 Side 1/4-20x 1" #3 (101.6) (1.5) (6.8) (2.4) (6.6) 7160 Vertical 1/4-20x #3 4 0.060 1,500 0.096 1,475 3/8 1-1/2" (101.6) (1.5) (6.8) (2.4) (6.6) 7186 Side 1/4-20x #3 4 0.060 1,500 0.096 1,475 (9.5) 1-1/2" (101.6) (1.5) (6.8) (2.4) (6.6) 7154 Vertical 12-20x 1-1/2 #5 4 0.060 1,475" 1,500 0.096 (101.6) 1 (1.5) (6.8) (2.4) (6.6) 7188 Side 1/4-20x2" #3 4 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1 500 , 0.096 7201 Side 12-20 x 1-1/2" #5 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7161 1/2 Vertical 12-20x 1-1/2" #5 8 0.250 4,050 0.250 3,800 (12.7) (203.2) (6.4) (18.2) (6.4) (17.1) 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver, For UL and FM listings, Steel Vertigo must be installed with a retaining nut. Wood Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) Listings for Pipe Hangers' Anchor Size / Rod Diameter Screw Shank Embedment Depth U Maximum UL Test Load FM MaximumL FM Test Load Cat. No. i n. Mount Direction Size and . in. Pipe Size lbs. Pipe Size lbs. (mm) Length (mm) i n. (mm) (kN) in. (mm) (kN) 7165 Vertical 1/4 x 2" 2 3 1,050 (50.8) - - (76.2) (4.7) 7170 Side 1/4x2" 2 3 1,050 (50.8) - - (76.2) (4.7) 7167 Vertical 1/4 x " 3 3 1,050 - - 3/8 (9.5) (76.2) (76.2) (4.7) 4 3 1,050 7169 Vertical 1/4 x " - - (101.6) (76.2) (4.7) 7162 Vertical 5/16" x2-1/2" 2-1/2 4 1,500 1,475 (63.5) 4 (101.6) (6.8) (101.6) (6.6) 7156 . Side 5/16" x2-112" 2-1/2 4 1,500 (63.5) - - (101.6) (6.8) 1. Wood Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. No pre-drilling was done in the wood base materials. Concrete Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) Listings for Pipe Hangers' Anchor Size I Rod Diameter Screw Shank Size ANSI Drill Bit Diameter Embedment Depth FM Maximum FM Test Load Cat. No. in. Mount Direction and d51 in. Pipe Size . lbs. Length (mm) in. (kN) (mm) i n. (mm) 7173 3/8 Vertical 1/4" x 1-1/2" 1/4" 1-1/2 (38.1) 4 (101.6) 1,475 (6.6) 7175 1/2 (12.7) Vertical 3/8" x2-3/4" 3/8" 2-3/4 (69.9) 4 (203.2) 3,800 (17.1) 1. Tabulated load values are for anchors installed in 8 inch thick hollow core plank with minimum compressive strength of 4,000 psi at the time of installation. The 4' x 6' normal-weight concrete Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 5 ?owers VertigoTM PRODUCT INFORMATION FASTENERS Steel Vertigo - Ultimate Load Capacities for Underwriter's Laboratories (UL) Listings - Luminaire1 Catalog Number Anchor Size/Rod Dia. In. (mm) Mount Direction Screw Shank Size and Length Point Style Mounting Surface UL Test Load (lb.) 7155 1/4 Vertical 1/4-20 x 1 #3 16 Gauge Steel 45 7157 3/8 Vertical 1/4-20 x 2 #3 16 Gauge Steel 45 7158 3/8 Vertical 1/4-20 x 1 #3 16 Gauge Steel 45 7159 3/8 Vertical 1/4-20 x 1-1/2 #3 16 Gauge Steel 45 7160 1/4 Vertical 1/4-20 x 1-1/2 #3 16 Gauge Steel 45 7183 1/4 Side 1/4-20 x 1 #3 16 Gauge Steel 75 7184 3/8 Side 1/4-20 x 1 #3 16 Gauge Steel 75 7186 3/8 Side 1/4-20 x 1-1/2 #3 16 Gauge Steel 75 7188 3/8 Side 1/4-20 x 2 #3 16 Gauge Steel 75 7155 1/4 Vertical 1/4-20x 1 #3 22 Gauge Steel 25 7157 1/4 Vertical 1/4-20 x 2 #3 22 Gauge Steel 25 7158 3/8 Vertical 1/4-20 x 1 #3 22 Gauge Steel 25 7159 3/8 Vertical 1/4-20x 1-1/2 #3 22 Gauge Steel 25 7160 3/8 Vertical 1/4-20 x 1-1/2 #3 22 Gauge Steel 25 7183 1/4 Side 1/4-20x 1 #3 22 Gauge Steel 45 7184 3/8 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7186 3/8 Side 1/4-20 x 1-1/2 #3 22 Gauge Steel 45 7188 3/8 Side 1/4-20x 2 #3 22 Gauge Steel 45 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. For UL Luminaire listing, Steel Vertigo does not require a retaining nut. www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 Cat. No. Description RPM std. Box Ctn. 7166 6'-12' Pole Tool (includes three Jaw Chuck) N/A 1 1 7187 Universal Steel & Wood Socket (Red) 500 to 1500 RPM 5 25 7195 1/4" Concrete Socket (Blue) - 5 25 7197 3/8" Concrete Socket (Blue) - 5 25 7198 1 1/2" Concrete Socket (Blue) - 5 25 Concrete Vertigo Installation Accessories Cat. No. Description Maximum Bit Length Std. Box Std. Ctn. Vertigo Installation Kit: 5864 1/4" and 3/8" Concrete Drive Sockets (Blue) 6" 1 3/4 Universal Steel & Wood Socket (Red) (Sleeve _Assembly _(same _as_Cat#_5874) 5874 Sleeve Assembly (5-3/4") 6" 1 - Cat. No. Description Usable Length Std. Wt./10 Tube 5866 1/4" x 6" Hex Shank SOS Drill Bit 4" 1 1 1/2 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertical Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Ctn. 7155 1/4" 1/4"-20x1" #3 0.036" (20 gauge) to 0.188" (3/16") 100 500 7157 3/8" 1/4"-20x2" #3 100 500 7158 3/8" 1/4-20 x 1" (w/nut) #3 100 500 7159 3/8" 1/4"-20x1-1/2"(w/nut) #3 100 500 7160 3/8" l/4"-20x 1-1/2" (w/nut) #3 100 1 500 7152 1/4" 12"-20x1-1/2" #5 0.188" (3/16") to 0.500" (1/2") 100 500 7154 3/8" 12"-20x1-1/2"(w/nut) #5 100 500 7161 1/2" 12"-20x1-1/2"(w/nut) #5 100 500 Steel Side Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Ctn. 7183 1/4" 1/4"-20x1" #3 0.036" (20 gauge) to 0.188" (3/16") 100 500 7184 3/8" 1/4-20 x 1" (w/nut) #3 100 500 7186 3/8" 1/4"-20 x 1-1/2" (w/nut) #3 100 500 7188 3/8" 1/4"-20x2" (w/nut) #3 100 500 7200 1/4" 1 12-20 x 1-1/2" #5 0.188" (3/16") to 0.500" (1/2") 50 300 7201 3/8" 1 12-20 x 1-1/2" (w/nut) #5 1 100 600 Wood Vertical Hanger Cat. No. Rod Dia. Screw Shank Size and Length Point Style Pre-Drill Diameter (If Required) Std Box Std. Ctn. 7163 1/4" 1/4"x2" Type 17 1/8" 100 500 7203 3/8" 1/4" x 1" Type 17 100 500 7165 3/8" 1/4"x2" Type 17 100 500 7167 3/8" 1/4" x3" Type 17 100 500 7169 3/8" 1/4" x4" Type 17 100 500 7162 3/8" 5/16"x2-1/2" Type 17 100 500 7164 1/2" 5/16"x2-1/2" Type 17 100 500 Wood Side Hanger Cat. No. Rod Dia. Screw Shank Size and Length Point Style Pre-Drill Diameter (If Required) Std Box 1 Std. I Ctn. 7185 1/4" 1/4"x1" Type 17 1/8" 100 1 500 7205 3/8" 1/4"x1" Type 17 100 I 500 7170 3/8" 1/4"x2" Type 17 100 I I 500 7156 3/8" 5/16" x2-1/2" Type 17 100 j 500 Concrete Vertical Hanger Cat. No. Rod Dia. I Screw Shank Size and Length I Thread I Style Pre-Drill Diameter (If Required) Std. Box Std. Ctn. 7171 1/4" 1/4" x 1-1/4" I Wedge-Bolt OT 1/4" ANSI 100 500 7173 3/8" 1/4" x 1-1/2" I Wedge-Bolt OT 1/4" ANSI 100 500 7175 1/2" 1/4" x 2-3/4" Wedge-Bolt OT 3/8" ANSI 50 250 Drive Sockets and Pole Tool © 2014 Powers Fasteners, Inc. All Rights Reserved. Vertigo is registered trademark of Powers Fasteners, Inc. For the most current product information please visit Www.powers.com e Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 7 2" Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring C®US LISTED Size Range - 1/2 thru 8' pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm 0r10mm 31/8 21/2 400 11 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 3/8 27/8 400 14 2 3/8 8mm or, 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/6 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 6-Y4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH; 951.737.5599 • FAX; 951.131.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 0 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 1/i 6 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13/16 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4"and 11/4" Throat Openings Component of State of California OSI-IPD Approved c Vi. us uso Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4' (Fig. 65) or 11/4 ' (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2' thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD. For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879-PH: 951.73T5599-FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwfolco,com