HomeMy WebLinkAbout1525 FARADAY AVE; 200; FPC2018-0094; Permitièity of Carlsbad Print Date: 04/20/2022 Permit No: FPC2018-0094 Job Address: 1525 FARADAY AVE, #200, CARLSBAD, CA 92008-7374 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121302700 Track #: Applied: 03/21/2018 Valuation: $139,530.00 Lot #: Issued: 04/10/2018 Occupancy Group: Project #: Finaled Close Out: 02/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: NEWPORT NATIONAL SPEC SUITE 200 - FIRE SPRINKLER TI (33 HEADS) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTMES INC DARIEN MORAN 12316 OAK KNOLL RD, # STE A 12316 OAK KNOLL RD POWAY, CA 92064-5363-SAN DIEGO P0 WAY, CA 92064-5363-SAN DIEGO (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov MATERIAL DATA SUBMITTAL Newport National Corporation Spec Suite - 200 Tenant Improvement 1525 Faraday Avenue, Suite #200 Carlsbad, CA 92008 FPC20I8-0094 1525 FARADAY AVE # 200 NEWPORT NATIONAL SPEC SUITE 200- FIRE SPRINKLER TI (33 HEADS) 2121302700 3/2112018 FPC20I 8-0094 I FIRE SYSTEMS, INC. Pacific Fire Systems, Inc. 12316 Oak Knoll Road, Suite A Poway, CA 92064 858-883-2333 Phone • 858-883-2334 Fax tqC0 Fire & Building 11Pro du c ts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series tgC.11'& EC. 14 - iii and 14,0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers General Description The Tyco® Series EC-11 and EC-14 Extended Coverage Upright and Pen- dent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 M2) for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for main fain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. DECEMBER, 2007 Model/Sprinkler Identification Number TY5137U prig ht, 11.2K T.Y5237-- Pendent, -i.1.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and S2510. 1Y5237 is a redesignation for C5237, G1893, and S2511. 1Y6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. TFP22O 16" nm 6* CROSS PENDENT SECTION Page 2 of 8 TFP22O 3/4" ** ESCUTCHEON PLATE NPT SEATING SURFACE 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2" (12,7 mm) J NOMINAL MAKE-IN UPRIGHT FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHTAND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT WRENCH 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5- Compression Screw 6 - Deflector* * Temperature rating is indicated on deflector ** Pipe thread connections per ISO 711 can be provided on special request. SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB NATURAL I CHROME I WHITE I LEAD LIQUID BRASS PLATED POLYESTER[ COATED 135°F/57"C Orange LIGHT UPRIGHT K11.2 (TY5137) 1, 2,3**, 4 155"F/68°C Red 175"F/79"C Yellow PENDENT Refer to Table B for K11.2 (TY5237) K14.0 (TY6237) 1,2,4 1,2,4 200"F/93°C Green 286°F/141"C Blue UL and C-UL 135°F/57"C Orange Sensitivity Rating and Refer to Table C for FM REC. PENDENT K=1 1.2 (TY5237) K14.0 (TY6237) 1, 2, 3, 4 N/A 155°F/68°C Red 175"F/79°C Yellow Sensitivity Rating With Style 30 Escutcheon 1,2,4 200°F/93"C Green 286"F/141°C Blue UPRIGHT 135°F/57°C Orange ORDINARY K=11.2 (TY5137) K14.0 (1Y6137) and 1, 2, 3, 4 1,2, 3,4 155°F/68°C Red 175°F/79°C Yellow Refer to Table B for UL and C-UL PENDENT K11.2 (TY5237) 1, 2, 4 200°F/93°C Green 286°F/141°C Blue Sensitivity Rating K=14.0 (TY6237) REC. PENDENT 135"F/57°C Orange and Refer to Table C for FM Sensitivity Rating K=1 1.2 (TY5237) K=14.0 (TY6237) With Style 40 1,2,4 N/A 155°F/68"C Red 175°F/79°C Yellow Escutcheon 200"F193"C Green NOTES: 11isted by Underwriters Laboratories, Inc. (UL). 21isted by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the City of New York under MEA 177-03-E. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. *Frame and Deflector only. Listings and approvals apply to color (Special Order). ** Pendent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS TFP220 Page 30f8 LIGHT HAZARD 135°F 155°F 175°F 200°F 286°F ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - OR OR OR OR 14 x 14 Style 30 Recessed - - - - - OR OR OR OR 14 x 14 Style 40 Recessed - - - - - OR OR OR OR 16x16 Up. orPend. QR* QR* QR* QR* QR* SR SR SR SR 16 x 16 Style 30 Recessed QR* QR* QR* QR* QR* SR SR SR SR 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 18 x 18 Up. or Pend. QR QR* QR* QR* QR* SR SR SR SR 18 x 18 Style 30 Recessed QR* QR* QR* QR* QR* SR SR SR SR 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 20 x 20 Up. or Pend. QR* QR* QR* SR* SR* SR SR SR SR 20 x 20 Style 30 Recessed QR* SR* QR* SR* SR* SR SR SR SR 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR OR Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K = 14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS (SEE TABLED FOR PERMITTED K-FACTOR/AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A 16 x 16 Up. or Pend. QR QR* N/A N/A N/A SR SR SR SR SR 16 x 16 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18x18 Up. orPend. QR* QR* N/A N/A N/A SR SR SR SR SR 18x18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up. or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 20x20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20x20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR Quick Response SR: Standard Response N/A: Not Applicable * Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-11 OR EC-14 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2-8N FOR PERMITTED K-FACTOR/AREA COMBINATIONS) SR N/A N/A SR N/A N/A SR N/A N/A SR N/A N/A Page 4 of 8 TFP22O Discharge Coefficients K = 11.2 GPM/psi112 2. (161,3 LPM/bar112) K = 14.0 GPM/psi112 (201,6 LPM/bar112) Technical Data Approvals The Series EC-11 and EC-14 Ex- tended Coverage Upright, Pendent, and Recessed Pendent Sprinklers are UL and C-UL Listed. (Refer to Table A for complete sprinkler approval infor- mation including corrosion resistant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are FM Approved. (Refer to Table A for complete sprinkler ap- proval information including corrosion resistant status. The approvals apply to the service conditions indicated in the Design Criteria section.) The Style 60 Two-Piece Flush Es- cutcheon (Ref. Figure 4) is UL Listed and FM Approved for use with the Se- ries EC-1 1 and EC-14 Pendent Sprin- klers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Temperature Ratings 135°F/57°C to 286"F/141°C Finish Sprinkler: Refer to Table A Recessed or Flush Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflon t Bulb ........Glass (3 mm dia.) Compression Screw ......... .......Bronze Deflector ............Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria The Tyco® Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indi- cated below. Only the Style 30 or 40 Recessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C).. UL and C-UL Listing Requirements 1. The Series EC-1 I and EC-14 Sprin- klers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. The Series EC-1 I and EC-14 Sprin- klers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, non-combustible, ceil- ing construction with a deflector lo- cation below structural members of 1 t 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-1 I and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted to be used within trusses or bar joists having non-combustible web mem- bers greater than 1 inch (25.4 mm) when applying the 4 times obstruc- tion criteria rule defined under "Ob- structions to Sprinkler Discharge Pattern Development". 4. The minimum allowable spacing be- tween the Series EC-1 1 and EC-14 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) for upright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. 5. The Series EC-1 I and EC-14 Sprin- klers are to be installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor- age, etc. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, 1Y6137 & TY6237) have a UL and C-UL Spe- cific Application Listing for use under concrete tees when installed as fol- lows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32 feet (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. 2. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM TFP22O Page 5 of 8 2-7/8 DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) - 2-1/4' DIA. 1/4" (6,4 FACE OF (57,2 mm) -1 1/8" SPRINKLER FITTING (3,2 mm) MIZ P7 MOUNTING / SURFACE// MOUNTING CLOSURE 7 PLATE (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-1 I AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) r (15,9±6,4 mm) 2-1/4" DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) SPRINKLER 1/8" FITTING (3,2 mm) I I \ MOUNTING/ SURFACE MOUNTING PLATE CLOSURE 1-3/8" (34,9 mm) 7/8" (22,2 mm) FIGURE 3 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de- signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. Installation The Series EC-11 and EC-14 Sprin- klers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 2860F/141°C temperature ratings. A 3/4 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 10 to 20 ft.Ibs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position, and upright sprinklers must be in- stalled in the upright position. Step 2. After installing the Style 30,40, or 60 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pen- dent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. When in- stalling the pendent sprinkler with Style 30, 40, or 60 Escutcheon, wrench tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. The wrench recess of the applicable sprin- kler wrench (Ref. Figure 5 and 6) is to be applied to the sprinkler wrench flats (Ref. Figure 1). 2-7/8" DIA. (73,0 mm) L...- 2-1/4" DIA. (57,2 mm) MOUNTING 1/8" SURFACE (3,2mm) / CLOSURE 3/4" NPT 2-5/16" (58,7 mm) - MOUNTING 1-13/16" (46,0 mm) PLATE INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE - IRON REDUCING SPRINKLER FITTING Page 6 of 8 TFP220 FACE OF SPRINKLER FITTING: 3/8' (9,5 mm) ABOVE TO 1/8"(3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4" (6,4 mm) ABOVE TO 1/2" (12,7 mm) BELOW MOUNTING SURFACE; 3/4(19,1 mm) TOTAL ADJUSTMENT Care and Maintenance The Tyco® Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with the follow- ing instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH ( RECESS (END FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH ance with local requirements and/or national codes. FIGURE 4 SERIES EC-1 I AND EC-I4 PENDENT SPRINKLER ASSEMBLY WITH 3/4 INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP220 Page 7of8 GROUP I GROUP II LIGHT HAZARD ORDINARY HAZARD ORDINARY HAZARD 0.10 GPM/FT2 0.15 GPM/FT2 0.20 GPM/FT2 DESCRIPTION AREA GPM PSI GPM PSI GPM PSI TY5137 (K11.2) UPRIGHT 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18x18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 51.0 TY5237 (K=11.2) PENDENT 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18x18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 51.0 TY6137 (K=14.0) UPRIGHT 14 x 14 N/A N/A - - - - 16 x 16 N/A N/A 39 7.8 51 13.3 18x18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 TY6237 (K14.0) PENDENT 14 x 14 - - - - - - 16 x 16 37 7.0 39 7.8 51 13.3 18x18 37 7.0 49 12.3 65 21.6 20x20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-1 I AND EC-I4 SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page 8 of 8 Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Re- fer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where applicable). Recessed Escutcheon, Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify material or finish*), P/N (specify). *Refer to Technical Data Sheet TFP77O. Flush Escutcheon, Two-Piece: Specify: Style 60 Two-Piece Flush Es- cutcheon with (specify finish*), P/N (specify). *Refer to Technical Data Sheet TFP778. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, P/N 56-665-7-001 P/N 51 - AAA - B -CCC AAA = 893 (for TY5237 K1 1.2 Pendent) AAA = 894 (for 1Y5137 K1 1.2 Upright) AAA = 895 (for TY6237 K14.0 Pendent) AAA = 896 (for TY6137 K14.0 Upright) B = 1 (for Natural Brass) B = 3 (for White [RAL9010])* B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 135°F/57°C) CCC = 155 (for 155°F/68°C) CCC = 175 (for 175°F/79°C) CCC = 200 (for 200°F/93°C) *Eastern Hemisphere sales only. TABLE PART NUMBERS FOR EC-11 AND EC-14 SPRINKLERS TFP22O © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqC0 Fire Suppression & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco-fire.com Series TY-FRB — 28, 42, 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. JULY 2010 Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2" NPT TY1231: Pendent 2.8K, 1/2" NPT TY2131: Upright 4.2K, 1/2" NPT TY2231: Pendent 4.2K, 1/2" NPT tY3131T Upright 56K, 1/2 NPT) TY3231:, Pendent .5.6K, 1/2NPTI 1Y4131: Upright 8.0K, 3/4- NPT 1Y4231: Pendent 8.0K, 3/4" NPT TY4831: Upright* 8.0K, 1/2- NPT TY4931: Pendent* 8.0K, 1/2" NPT 'Eastern Hemisphere Sales Only TFPI7I 7/16(11,1 mm) ESCUTCHEON PLATE SEATING SURFACE / 2-1/4 (57,2 mm) -9/16 ),7 mm) 1/2' NPT SSP DEFLECTOR* STYLE 10 0r20 RECESSED ESCUTCHEON 2-7/8 (73,0 mm) DIA. SSU * NOMINAL DEFLECTOR MAKE-IN 1 6* 7/16 I 11,11 mm) 32 I NOMINALw WRENC MAKE-IN -3/16 5,6 mm) (5 FLATS 1/2 NPT TFPI7I Page 2 of 10 CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly * Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw 7 - Bushing FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY113I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 7/16 (11,1 mm) ESCUTCHEON SSU * NOMINAL PLATE SEATING DEFLECTOR NPT MAKE-IN SURFACE / 6* _ a___________________________________ 5 (11,1 mm) I1VTl.L\\11\ I 2-3/16' 7/16 NOMINAL ) (55,6 mm) 1/2 3/16' I _____ mm) ______ WRENCH MAKE-IN FLATS (38,1 (556mm) ______ 1/2" NPT SSPDEFLECTOR* STYLE 100r20 RECESSED ESCUTCHEON 2-7/8' (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT STYLE 10 or 20 RECESSED ESCUTCHEON TFPI7I Page 3 of 10 6* 7/16' 5 (1111,11 mm) 2-3/16" I NOMINAL 55,6 mm) I MAKE-IN JWRENC/1] I 2 2- __ : (55,6 mm) _________ 1-1/2" 3/16' FLATS (38,11 mm) 1/2' NPT SSP DEFLECTOR* 2-7/8' (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT SSU* DEFLECTOR 1/2" (12,7 mm) ESCUTCHEON NOMINAL PLATE SEATING NPT SU RFACE URFACE 2-5/16" (58,7 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR * STYLE 30 or 40 RECESSED ESCUTCHEON 6* 5 1 1/2" I (12,7 mm) : 2 NOMINAL MAKE-IN -1/4" ri 2mm) 3/4" NPT 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Assembly Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT 7/16(11,1 mm) SSU * NOMINAL DEFLECTOR MAKE-IN 1/2" NPT ESCUTCHEON PLATE SEATING SURFACE TFPI7I Page 4 of 10 7/16' (11,1 mm) SSU * NOMINAL DEFLECTOR MAKE-IN 1/2' NPT 6 7/16" 2-1/4' 5 1 1"I mm) _________ 4 I ______ 7,2 mm) NOMINAL 5 T/(55,6mm) MAKE-IN 2-3/16' I / 1-9/16' WRENCH (39,7 mm) ____________ _______ FLATS _ SSP*—.,. 1/2' NPT DEFLECTOR CROSS SECTION UPRIGHT PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly Temperature rating is indicated on deflector or adjacent to 2 - Button - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 80 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi'/2 (40,3 LPM/bar1'2) K=4.2 GPM/psi1'2 (60,5 LPM/bar1'2) K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K=8.0 GPM/p51112 (115,2 LPM/bar1'2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/Teflont Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze t Registered Trademark of Dupont Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F157°C and 3/32 inch (2,4 mm) for the 286°F/1410C temperature ratings. Obtain a leak-tight 1/2 inch NPT sprin- kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/571C Orange 1, 2, 3, 4 155°F/68°C Red 175°F/79°C Yellow 200FI93°C Green 286°F/141°C Blue RECESSED (TY1231)* Figure 6 135°F/57C Orange 1,2,4 PENDENT 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231)** Figure 7 135°F/57C Orange 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1,2 155F/68°C Red 175°F/79°C Yellow 200°F193°C Green 286F/141°C Blue RECESSED PENDENT (1Y2231)* Figure 8 135F/57C Orange 1 55°F/68°C Red 175°F/79°C Yellow 200°F193°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F157°C Orange 155F/68°C Red 175°F/79°C Yellow 200F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2, 3,4,5, 6, 7 Blue 1,2, 3, 5 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2, 4, 5 Blue N/A 155°F/68C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY3231)** Figure 11 135°F/57°C Orange 1, 2, 3, 4, 5 Blue N/A 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 286°F/141°C 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93C Green 286°F/141°C RECESSED PENDENT (TY4231)* Figure 12 135°F/57C Orange 1, 2, 5 Blue N/A 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green 286°F/141°C RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1, 2, 3, 5 Blue N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141C 80 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL J CHROME WHITE LEAD FACTOR BRASS PLATED I POLYESTER COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) N/A PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and 175 PSI (12,1 BAR) (12,1 BAR) UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) Only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TABLE C MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. TFPI7I Page 8 of 10 2-7/8 DIA. 5/8±1/4 - (73,0 mm) 3/4° (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4" (6,4 mm) FACE OF MM -:1 MOUNTING SPRINKLER \ / I - PLATE FITTING MOUNTING ti1Y SURFACE/ 1-5/16' (33,3 CLOSURE SERIES mm TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4' (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) I 2-1/4" DIA. 1/4' (6,4 mm) FACE OF mm) MOUNTING SPRINKLER PLATE FITTING 1/8" mm) 1 MOUNTING SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE TYFRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. - - (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) - (12,7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) P77 7/ MOUNTIN G SURFACE 6 (33,3 mm) '[ CLOSURE SERIES TY-FRB 1-1/16 (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - (73,0 mm) 1/2±1/8" 1/2' (12,7 mm) E (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (572 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) \ MOUNTING SURFACE SERIES 1-1/4"(31,8mm) CLOSURE TYFRB 1 '(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4 (6,4 mm) (57,2 mm) I MOUNTING I DIAT I 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING I \ - MOUNTING SURFACE CLOSURE SERIES _ m) 1-1/4" (31,8 mm) 1" (25,4 mm) TFPI7I Page 9 of 10 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) I 1/4' (6,4 mm) I 2-1/4' DIA. - FACE OF (57,2 mm) MOUNTING SPRINKLER I PLATE FITTING 1/8" MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) I 3/4" (19,1 mm) 2-1/4" DIA. 1/4(6,4mm) I (57,2 mm) MOUNTING PLATE I 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)1 TY-FRB 13/16(20,6mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2"(12,7mm) (12,7±3,2 mm) 2-1/4" DIA. i 1/4" (6,4 mm) (57,2 mm) FACE OF I I MOUNTING SPRINKLER L 7) PLATE FITTING I - I (3,2 MM) Z. AIT'ffll - MOUNTING / SURFACE // / I CLOSURE SERIES 1-5/16"(33,3mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX L MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831° 361 8.0K PENDENT (1/2"NPT) TY4931° SPRINKLER TEMPERATURE L FINISH RATINGS 1 NATURAL BRASS 135 135-F (57-C) 4 I WHITE POLYESTER I I 155 1 155°F (68°C) 3 WHITE (RAL9010)* 175 175° F (79°C) 9 CHROME PLATED 200 200°F (93°C) 7 I LEAD COATED I I 286 1 286°F (141°C) * Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a øarticular ouroose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Refer to Technical Data Sheet TFP770. Copyright © 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. FM Approved and Fully Listed Sprinkler Pipe Wheatland's WLS steel fire sprinkler pipe is hot-dip galvanized to meet FM requirements for dry systems and is UL, C-UL and FM Listed. Approvals and Specifications The product meets or exceeds the following standards: ASTM: A795, Type F, Grade A ANSI/ASME B1.20.1 pipe threads NFPA13 Manufacturing Protocols WLS is subjected to the toughest possible testing protocols to assure the highest quality and long-lasting performance. Finishes and Coatings WLS is finished in black or hot-dip galvanized. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SPECIFICATIONS NIPS NOM OD NOM ID UL CRR WLS I Schedule Schedule Schedule Nominal PCs./ PCs./ LS i'10 40 WLS 40 wt./ft. Lift 21' Lift 25' 1 1.315 1.087 N/A 1.049 .57 1.00 1.462 70 60 11/4 1 1.660 1.426 1.442 1.380 .46 1.00 1.928 55 45 11/2 1.900 1.650 1.682 1.610 .64 1.00 2.370 45 40 2 , 2.375 2.125 2.157 2.067 .52 1.00 3.004 35 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. @ C(E) APPROVED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 BLACK 0 HOT-DIP GALVANIZED t D11 Tube JMC STEEL GROUP Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8" thru 7/8" rod by 4" thru 16" length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1". Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 Specify 1/2 9/16 Specify 2 5/8 11/16 Specify 3/4 13/16 Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. Component of State of California OSHPD Approved C Us usmo Seismic Restraints System OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH; 951.737.5599 • FAX; 951.737.0330 CUSTOMER SERVICE • 800.786.5266 .4 www.tolco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1e 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13/is 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 314" and 11/4" Throat Openings Component of State of California OSHPD Approved c VL us LISTEDSeismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD'. For additional load, spacing and placement relating to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICEIMANUFACTIJRING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951 737.0330 'I CUSTOMER SERVICE • 800.786.5266 www.folco.com Fig. 2 - Adjustable Band Hanger Size Range - Size 21/2 thru 6 pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs. Wt./100 21/2 1/2* 53/4 41/4 1/8 600 41 3 1/2* 6 41/8 11/4 600 45 31/2 1/2* 7/8 51/4 21/8 600 52 4 5/8* 7/8 5 15/8 1000 59 5 5/8 9 61/8 21/4 1250 97 6 3/4** 9/8 61/2 1/8 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.com 271 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Vertigo TM Rod Hangers Vertigo is an all steel threaded fastening system for suspending steel threaded rod vertically overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. Vertigo are available in three versions which can be installed in a variety of base materials including steel purlins, bar joists and beams, wood frame columns and beams, as well as concrete ceilings, beams and columns. Steel threaded rods in 1/4", 3/8" and 1/2" diameters can be vertically suspended with Vertigo. In wood and steel base materials, Vertigo is also offered in a side mount style for lateral installation of 1/4" and 3/8" diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood Vertigo fasteners, a universal Vertigo Socket Driver is recommended to provide proper installation with a screw gun or hammer drill. Concrete Vertigo fasteners should be installed with the appropriate size standard drive sockets and adjustable torque, battery powered screw gun or hammer drill. Hanging Pipe and Sprinkler Systems • Suspending Conduit and Cable Trays Lighting Systems and Overhead Utilities • HVAC Ductwork and Strut Channels Suspended Ceilings • Mounting Security Equipment One system for all rod hanging applications in steel, wood and concrete + Ease and speed of overhead installation + Lower in-place cost, when compared to beam clamps, lag bolts and dropins + Steel and wood Vertigo can be installed with a screw gun or hammer drill + Concrete Vertigo can be installed with an adjustable torque, battery powered screw gun or hammer drill + Side mount versions available for steel and wood Vertigo + The universal socket can be used for the steel and wood Vertigo FM Approvals (FM) - (see listing for applicable sizes and types). Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 Underwriters Laboratory (UL) - (see listing for applicable sizes and types). Pipe Hangers - File No. EX 1289 Luminaire - File No. E362339 CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 19 - Post-Installed Concrete Anchors, 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Vertigo anchors as supplied by Powers Fasteners, Inc., Brewster, NY. SECTION CONTENTS Page No. General Information....................1 Installation Specifications............2 Material Specifications ...............2 Performance Data ........................3 Ordering Information..................7 Steel Vertigo Wood Vertigo - Concrete Vertigo '(Wedge-Bolt OT) ANCHOR MATERIALS Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYP.) 1/4" to 1/2" for Steel 1/4" to 1/2" for Wood 1/4" to 1/2" for Concrete SUITABLE BASE MATERIALS Steel Purlins and Beams Wood and Timber Normal-Weight concrete Structural Lightweight concrete Hollow Core Concrete Plank Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com ?owers VertigoTM PRODUCT INFORMATION FASTENERS Steel Vertigo Point Style #3 #5 Self Drilling Range 0.036" (20 gauge) - 0.188" (3/16") 0.188" (3/16") - 0.500" (1/2") Screw Size (UNC) 1/4-20 thread 1/4-20 thread Root Diameter (in.) 13/64 13/64 Thread Length (in.) 1-3/16" (1-1/2"screw) 31/32"(1-112"screw) Flange Thickness (in.) 1/16 1/16 Drill Speed (RPM) 500-1,500 500-1,500 Install with universal steel and wood socket. Wood Vertigo Screw Size 114" Thread Forming 5/16" Thread Forming Pre-drill Diameter (in.) (if required) 1/8 1/8 Point Style Type 17 Type 17 Root Diameter (in.) 3/16 7/32 Thread Length (in.) Screw length less 5/16 Screw length less 5/16 Flange Thickness (in.) 1/16 1/16 Install with universal steel and wood socket. Installation Guidelines When installing Vertigo <• - fasteners, eye protection , .. should be worn as a . safety precaution. . .A . . ' If pre-drilling is required . (certain types of wood truss/wood joist and all concrete base materials), select the recommended drill bit type and diameter. For Concrete Vertigo only, drill to the appropriate embedment depth, adding at least one diameter (1/4" to 1/2") to the drilling depth to prevent the tip of the fastener from running into a dead end at the rear of the anchor hole. Concrete Select the appropriate socket driver for the anchor size and type to be installed and mount into chuck of installation tool. Insert the Vertigo fastener into the socket driver, and - install perpendicular to the base material surface. Drive the fastener with a smooth steady motion until the coupling is firmly seated against the surface of the base material. Vertigo Couplings (Steel & Wood) Screw Size 1/4" 3/8" 1/2" 1/4" 3/8" Coupling Size and Type Vertical Vertical Vertical Side Side Thread Size (UNC) 1/4-20 3/8-16 1/2-13 1/4-20 3/8-16 Thread Depth (in.) 3/8 3/8 3/8 5/8 5/8 (through) (through) Width (flat to flat) (in.) 5/8 5/8 5/8 5/8 5/8 Height (in.) 13/16 13/16 13/16 13/16 13/16 ConcretéVertigo (Wedge-Bolt OT) Rod Diameter/Anchor Size 1/4" ( 3/8" 1 ANSI Drill Bit (in.) 1/4 1/4 3/8 Overall Screw Shank Length 1-1/4 1-1/2 2-3/4 Anchor Thread Length (in.) 1-1/8 1-3/8 2-1/2 Root Diameter (in.) 15/64 15/64 23/64 Coupling IWasher Height (in.) 27/64 9/16 53/64 Integral Washer O.D. (in.) 31/64 39/64 31/32 Coupling Thread Size (UNC) 1/4-20 3/8-16 1/2-13 Coupling Thread Depth (in.) 3/8 1/2 3/4 Socket Driver Size (in.) 3/8 1/2 11/16 Install with universal steel and wood socket. Thread the appropriate diameter steel threaded rod or threaded bolt into the coupling. The threaded rod or bolt should fully engage the thread length of the coupling on a vertical mount fastener. The threaded rod or threaded portion of the bolt can pass through coupling of a side mount fastener. For UL and FM listings for Pipe Hangers, Steel Vertigo should be installed with a retaining nut. Steel and Wood Vertigo Component Component Material Screw Body AISI 1018-1022 (Case Hardened) Coupling AISI 1018-1022 (Case Hardened) Zinc Plating ASTM 8633, SC1,Type Ill (Fe/Zn5) Concrete Vertigo (Wedge-Bolt OT) Component Component Material Anchor Body Case Hardened 10821 Carbon Steel Zinc Plating ASTM 8633, SC1,Type III (Fe/Zn 5) 2 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers. FASTENERS PRODUCT INFORMATION VertigoTM PERFORMANCE DATA Steel Vertigo - Ultimate Tension Load Capacities when Installed in Minimum ASTM A 36 Steel (Beams) and ASTM A 572 Steel (Purlins)1'2 Anchor Size / Minimum Steel Gauge (Thickness) _____________ _____________ 20 0.036 18 0.048" 16 0.060" 14 0.075" 12 0.105" 3116" 0.187" 114" 0.250" Rod Diameter in. Mount Direction Screw Shank Size and Length (mm) lbs. lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) (kN) Vertical 1/4-20 x 1" (w/nut) 1.550 1,550 1,775 1,775 2,050 3,850 (70) (7.0) (8.0) (8.0) (9.2) (17.3) - 1/4 Vertical 1/4-20 x 1 " 405 620 985 1,160 1,560 3,205 5,040 (6.4) (1.8) (2.8) (4.4) (5.2) (7.0) (14.4) (22.7) Side 1/4-20 x 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Vertical 1/4-20 x 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Side 114-20x1-1/2"(wlnut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 3/8 Vertical 1/4-20 x 1-1/2 " 405 620 985 1,160 1,560 3,205 (9.5) (1.8) (2.8) (4.4) (5.2) (7.0) (14.4) - Side 1/4-20 x 1-1/2" 405 620 985 1,160 1,560 1,965 (1.8) (2.8) (4.4) (5.2) (7.0) (8.8) - Vertical 1/4-20 x 2" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Vertical 12-20x 1-1/2" 495 710 920 1,560 2,050 3,280 5,040 1/2 (2.20 (3.2) (4.1) (7.0) (9.2) (14.8) (22.7) (12.7) Vertical 12-20x1-1/2"(w/riut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 1. For Steel Vertigo loaded perpendicular to threaded rod (shear) the ultimate load capacity for the anchor is 1,965 lbs in nominal 20 gage steel (0.036") Wood Vertigo - Ultimate Tension Load Capacities when Installed in Wood Base Materials (Structural Wood and Timber)'., Anchor Size / Embedment Depth Wood Member (Type) _______________________ Fir Pine Spruce Rod Diameter Mount Screw Shank Size . in. Direction and Length In. (mm) lbs. lbs. lbs. (mm) (kN) (kN) (kN) 1/4 Vertical 1/4 x 1 1 (25.4) 685 (3.1) 650" 650 (2.9) (2.9) (6.4) Side 1/4x2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Vertical 1/4x 1" 1 (25.4) 685 (3.1) 650 (2.9) 650 (2.9) Side 1/4x1 " 1 (25.4) 685 (3.1) 650 (2.9) 650 (2.9) Vertical 1/4x2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Side 1/4x2" 2 1,800 1,800 1,800 3/8 (50.8) (8.1) (8.1) (8.1) (9.5) Vertical 1/4x3" 3 2,075 1,510 1,510 (76.2) (9.3) (6.8) (6.8) Vertical 1/4x4" 4 2,075 1,510 1,510 (101.6) (9.3) (6.8) (6.8) Vertical 5/16" x2-1/2" 2-1/2 2,670 3,110 3,110 (63.5) (12.0) (14.0) (14.0) Side 3/8" x 2-1/2" 2-1/2 1,450 1,530 1,380 (63.5) (6.5) (6.9) (6.2) 1/2 Vertical 5/16" x2-1/2" 2-1/2 2,670 3,110 3,110 (12.7) (63.5) (12.0) (14.0) (14.0) Truss/joist manufacturers may require pre-drilled holes with wood depending on the location of the anchor installation. Consult with the truss/joist manufacturer for details. Wood Vertigo are recommended to be installed with the Universal Steel & Wood Nut Driver. Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 wwwpowers.com 3 ?owers VertigoTM PRODUCT INFORMATION FASTENERS Concrete Vertigo - Ultimate Load Capacities when Installed in Normal-Weight Concrete'.' Anchor Size ! ANSI Drill Bit Minimum Concrete Compressive Strength (f c) Embed. Depth psi (13.8 MPa) 4,000 psi (20.7 MPa) 6,000 psi (41.4 MPa) Rod Diameter Mount Screw Shank Size Diameter k 2,000 Tension Shear Tension Shear Tension Shear in. Direction and Length dbit in. (mm) in. (mm) lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) 1/4 Vertical 1/4" x 1-1/4 " 1/4 1-1/4 1,390 1,810 1,950 . 2,440 2,070 2,570 (6.4) (31.8) (6.3) (8.1) (8.8) (11.0) (9.3) (11.6) 3/8 Vertical 1/4" xl-1/2 " 1/4" 1-1/2 1,760 2,580 2,595 2,640 2,770 2,700 (9.5) (38.1) (7.9) (11.6) (11.7) (11.9) (12.5) (12.2) 1/2 Vertical 3/8"x2-3/4" 3/8" 2-3/4 5,320 5,250 6,050 6,330 8,620 7,410 (12.7) (69.9) (23.9) (23.6) (27.2) (28.5) 1 (38.8) (33.0) The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Linear interpolation may be used to determine ultimate loads for intermediate compressive strengths. c'TiConcrete Vertigo - Ultimate Load Capacities when Installed Through Metal Deck into Structural Lightweight Concrete' .13.4 Lightweight Concrete Over Minimum 20 Ga. Metal Deck Anchor Size! Rod Diameter Embedment Depth ft ~t 3,000 psi (20.7 MPa) Minimum 41/2" Wide Deck d in. Tension Load at 45° in. (mm) (mm) lbs. lbs. (kN) (kN) 1/4 1-1/4 800 11140 (6.4) (31.8) (3.6) (5.1) 3/8 1-1/2 1,780 1,500 (9.5) (38.1) (8.0) (6.8) 1/2 2-3/4 3,880 2,920 (12.7) (69.9) (17.5) (13.1) The values listed above are ultimate and allowable toad capacities for Vertigo rod hangers installed in sand-lightweight concrete. The metal deck shall be minimum No. 20 gauge thick steel 10.035-inch base metal thickness (0.89 mm)] conforming to ASTM A 653/ A 653M. 3, The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. 4. The tabulated load values are for anchors installed with a minimum flute edge distance of 1-1/2-inch. Concrete Vertigo - Ultimate Tension Load Capacities when Installed in Hollow Core Concrete Plank',' Anchor Size! Rod Diameter ANSI Drill Bit Diameter Embedment Depth Center of Web Center of Core Mount Screw Shank Size lbs. lbs. in. Direction and Length dbit . (kN) (kN) (mm) in. (mm) 1/4 (6.4) Vertical 1/4"x l-1/4" 1/4" 1-1/4 2,775 (12.3) 1,920 (31.8) (8.5) 3/8 Vertical 1/4"x 1-1/2" 1/4" 1-1/2 3,700 2,570 (38.1) (9.5) (16.5) (11.4) 1/2 (12.7) Vertical 3/8"x2-314' 3/8" 2-3/4 8,240 (36.7) 3,480 (69.9) (15.5) Tabulated load values are for anchors installed in 8-inch-thick hollow core plank with minimum compressive strength of 5,000 psi at the time of installation. The 4' x 6' normal-weight concrete members features include 1-1/2" cover above and below cores and a minimum web thickness of 1-1/2". The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM IPERFORMANCE DATA Steel Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) Listings for Pipe Hangers' Anchor Size / Maximum U L Minimum FM Minimum Rod Diameter Mount Screw Shank Pipe Size Steel UL Test Load Steel FM Test Load Cat. No. in. Direction Size and Point Style . Thickness lbs. Thickness lbs. (mm) Length Ifl. (mm) .fl. I (kN) in. (kN) (mm) (mm) 7158 Vertical 1/4-20 x " #3 4 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7184 Side 1/4-20x1" #3 4 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7160 Vertical 1/4-20 x #3 4 0.060 1,500 0.096 1,475 3/8 1-1/2" (101.6) (1.5) (6.8) (2.4) (6.6) 7186 Side 1/4-20 x #3 4 0.060 1,500 0.096 1,475 (95) 1-1/2" (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1,475" 1,500 0.096 7154 Vertical 12-20 x 1-1/2 #5 (101.6) (1.5) (6.8) (2.4) (6.6) 7188 Side 1/4-2002" #3 4 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7201 Side 12-200 1-1/2" #5 4 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7161 1/2 Vertical 12-20x1-1/2" #5 8 0.250 4,050 0.250 3,800 (12.7) (203.2) (6.4) (18.2) (6.4) (17.1) 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. For UL and FM listings, Steel Vertigo must be installed with a retaining nut. Wood Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) Listings for Pipe Hangers' Anchor Size! Rod Diameter Screw Shank Embedment Depth UI Maximum UL Test load FM Maximum FM Test Load Cat. No. in. Mount Direction Size and . Pipe Size lbs. Pipe Size lbs. (mm) Length in. (mm) i n. (mm) (kN) in. (mm) (kN) 7165 Vertical 1/40 2" 2 3 1,050 - - (76.2) (4.7) 2 3 7170 Side 1/4 x 2" 1,050 (50.8) - - (76.2) (4.7) 3 3 1,050 7167 Vertical 1/4 x ' - - 3/8 (9.5) (76.2) (76.2) (4.7) 4 3 1,050 7169 Vertical 1/4 x " - - (101.6) (76.2) (4.7) 7162 Vertical 5/16" x2-1/2" 2-1/2 4 1,500 4 1,475 (63.5) (101.6) (6.8) (101.6) (6.6) 7156 Side 5/16" x2-1/2" 2-1/2 4 1,500 - - 1 (101.6) 1 (6.8) _ 1. Wood Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. No pre-drilling was done in the wood base materials. Concrete Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) Listings for Pipe Hangers' Anchor Size! Rod Diameter Mount Screw Shank Size ANSI Drill Bit Diameter Embedment Depth FM Maximum Pipe Size FM Test Load Cat. No. in. Direction and Length in. (mm) . in. lbs. (kN) (mm) in. (mm) 7173 3/8 (9.5) Vertical 1/4" x 1-1/2" 1/4" 1-1/2 (38.1) 4 (101.6) 1,475 (6.6) 7175 1/2 (12.7) Vertical 3/8" x2-3/4" 3/8" 2-3/4 (69.9) 4 (203.2) 3,800 (17.1) 1. Tabulated load values are for anchors installed in 8 inch thick hollow core plank with minimum compressive strength of 4,000 psi at the time of installation. The 4' x 6' normal-weight concrete Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powerscom 2owers VertigoTM PRODUCT INFORMATION FASTENERS Steel Vertigo - Ultimate Load Capacities for Underwriter's Laboratories (UL) Listings - Luminaire1 Catalog Number Anchor Size/Rod Dia. In. (mm) Mount Direction Screw Shank Size and Length Point Style Mounting Surface ULlest Load (lb.) 7155 1/4 Vertical 1/4-20 x 1 #3 16 Gauge Steel 45 7157 3/8 Vertical 1/4-20 x 2 #3 16 Gauge Steel 45 7158 3/8 Vertical 1/4-20 x 1 93 16 Gauge Steel 45 7159 3/8 Vertical 114-20 x 1-1/2 #3 16 Gauge Steel 45 7160 1/4 Vertical 114-20 x 1-1/2 #3 16 Gauge Steel 45 7183 1/4 Side 1/4-20 x 1 #3 16 Gauge Steel 75 7184 3/8 Side 1/4-20 x 1 #3 16 Gauge Steel 75 7186 3/8 Side 1/4-20 x 1-1/2 #3 16 Gauge Steel 75 7188 3/8 Side 1/4-20 x 2 #3 16 Gauge Steel 75 7155 1/4 Vertical 1/4-20 x 1 #3 22 Gauge Steel 25 7157 1/4 Vertical 1/4-20 x 2 #3 22 Gauge Steel 25 7158 3/8 Vertical 1/4-20 x 1 #3 22 Gauge Steel 25 7159 3/8 Vertical 1/4-20 x 1-1/2 #3 22 Gauge Steel 25 7160 3/8 Vertical 1/4-20 x 1-1/2 #3 22 Gauge Steel 25 7183 1/4 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7184 3/8 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7186 3/8 Side 1/4-20 x 1-1/2 #3 22 Gauge Steel 45 7188 3/8 Side 1/4-20 x 2 #3 22 Gauge Steel 45 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. For UL Luminaire listing, Steel Vertigo does not require a retaining nut, www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 Cat. No. Rod Dia. Screw Shank I I Size and Length I Thread Style Pie-Drill Diameter (If Required) Std. Box Std. Ctn. 7171 1/4" 1/4" x 1-1/4'_':__.1. Wedge-BoltOT 1/4" ANSI 100 500 7173. :3/8" 1/4x-1-1/2" 1 -Wedge-Bolt 0T1 1/4" ANSI 100 500 7175 1/2" 1/4" x 2-3/4" Wedge-Bolt OT 3/8" ANSI 50 250 Drive Sockets and Pole Tool Cat. No. Description RPM Std. Box Ctn. 7166 6-12' Pole Tool (includes three Jaw Chuck) N/A 1 1 7187 Universal Steel & Wood Socket (Red) 500 to 1500 RPM 5 - 25 7195 1/4" Concrete Socket (Blue) - 5 25 7197 3/8" Concrete Socket (Blue) - 5 25 7198 1/2" Concrete Socket (Blue) - - 5 25 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertical Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Ctn. 7155 1/4" 1/4"-20x1" #3 0.036" (20 gauge) to 0.188" (3/16") 100 500 7157 3/8" l/4"-20x2" #3 100 500 7158 3/8" 1/4-20 x 1" (w/nut) #3 100 500 7159 3/8" 114"-20 x 1-112" (w/nut) 43 100 500 7160 3/8" 1/4-20 x 1-1/2" (w/nut) #3 100 500 7152 1/4" 12"-20x1-112" #5 0.188"(3116")to 0.500" (1/2") 100 500 7154 3/8" 12"-20x1-1/2"(wlnut) #5 100 500 7161 1/2" 12"-20x1-1/2"(w/nut) #5 100 500 Steel Side Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Ctn. 7183 1/4" 114"-20x1" #3 0.036" (20 gauge) to 0.188" (3/16") 100 500 - 7184 3/8" 1/4-20 x 1" (w/nut) #3 100 500 7186 3/8" 1/4"-20x1-1/2"(w/nut) 43 100 500 7188 3/8" 1/4"-20 x 2" (w/nut) #3 100 500 7200 1/4" 12"-20x1-1/2" #5 0.188"(3116")to 0.500"(1/2") 50 300 7201 3/8" 12"-20x1-1/2"(w/nut) #5 100 600 Wood Vertical Hanger Cat. No. Rod Dia. Screw Shank Size and Length Point Style Poi Pie-Drill Diameter (If Required) Std Box Std. Ctn. 7163 1/4" 1/4"x2" Type 17 1/8" 100 500 7203 3/8" 1/4" xl" Type 17 100 500 7165 3/8" 1/4" x2" Type 17 100 500 7167 3/8" 1/4" x3" Type 17 100 500 7169 3/8" 1/4" x4" Type17 100 500 7162 3/8" 5/16" x 2-1/2" Type 17 100 500 7164 1/2" 5/16" x 2-1/2" Type 17 100 500 Wood Side Hanger Cat. No. Rod Dia. Screw Shank Size and Length Point Style Pre-Drill Diameter (If Required) Std Box T Std. I Ctn. 7185 1/4" 1/4" xl" Type 17 1/8 " 100 t 500 7205 3/8" 1/4" xl" Type 17 100 500 7170 3/8" 1/4" x 2" Type 17 100 I 500 7156 3/8" 5/16" x2-1/2" Type 17 100 500 Concrete Vertical Hanger Concrete Vertigo Installation Accessories Cat. No. Description Maximum Bit Length Std. Box Std. Ctn. Vertigo Installation Kit: 5864 1/4" and 3/8" Concrete Drive Sockets (Blue) 6" 1 3/4 Universal Steel & Wood Socket (Red) (Sleeve _Assembly _(same _as_Cat#_5874) 5874 Sleeve Assembly (5-3/4") 6" 1 - Cat. No. Description Usable Length Std. wt./10Tube 5866 1/4" x 6" Hex Shank SDS Drill Bit 4" 1 1/2 © 2014 Powers Fasteners, Inc. All Rights Reserved. Vertigo is a registered trademark of Powers Fasteners, Inc. For the most current product information please Visit www.powers.com Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com