HomeMy WebLinkAbout1635 FARADAY AVE; ; FPC2018-0145; Permit(ity of Carlsbad I rIs]i tI1ift. - Print Date: 04/20/2022 Job Address: 1635 FARADAY AVE. CARLSBAD, CA 92008-7314 Permit Type: FIRE-Construction Commercial Work Class: Special Equipment Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: FARADAY SERVER ROOM -INSTALL FM200 CLEAN AGENT IN SERVER ROOM Permit No: FPC2018-0145 Status: Closed - Finaled Applied: 05/14/2018 Issued: 05/30/2018 Finaled Close Out: 02/25/2021 Inspector: Final Inspection: Applicant: FPContractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JOHN MOCKER 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE Special Extinguishing System $568.00 Total Fees: $700.00 Total Payments To Date: $700.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 1 I www.carlsbadca.gov San Diego Branch Office cosco 4990 Greencraig Lane ''•IS... I San Diego, CA 92123 :'..."' s." Fire Protection (858) 444-2000 fax: 444-2056 CA Lie.: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL & CALCULATIONS Date: 4-26-18 CARLSBAD SERVER ROOM. 1635 FARADAY AVE SAN DIEGO, CA. 92008 JOB # 1O.CA_5398 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: HUGO A. - Los Angeles 0 San Francisco 0 Orange • Fresno • San Diego • Seattle Page 1 of The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking EC/QREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Light and Ordinary Hazard density re- quirements at lower pressures than standard orifice or large orifice sprinklers. The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. Pendent Sprinkler VK534 is cULus Listed as standard and quick response. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, ENT coating has been investigated for installation in corrosive atmospheres. See Approval Charts. LISTINGS AND APPROVALS CrEls cULus Listed: Category VNlV Refer to Approval Chart 1 and Design Criteria cULus Listing requirements. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K-Factor: 11.2 U.S. (161.3 metrict) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8' (61 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Viking Technical Data may be found on For Polyester Coated Sprinklers: Belleville Spring-Exposed The Viking Corporation's Web site at For ENT Coated Sprinkler: Belleville Spring-Exposed, Screw and Pipcap- http://www.vikinggroupinc.com. ENT plated. The Web site may include a more recent Ordering Information: (Also refer to the current Viking price list.) edition of this Technical Data Page. Order Viking EC/QREC Pendent Sprinkler VK534 by first adding the appro- priate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 C) = B, 175 F (79 °C) = D, 200 "F (93 "C) = E, and 286 "F (141 "C) = G For example, sprinkler VK534 with a Brass finish and a 155 "F (68 "C) temperature rating = Part No. 08340AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 05118CW/B (available since 1981) Wrench for recessed pendent sprinkler: Part No. 11663W/B" (available since 2001) "A % ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) Form No. F_051393 Rev 15.1 Page 2 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking ECIQREC Pendent Sprinkler VK534 is available through a network of domestic and international distributors. See The 'liking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat - Protective Sprinkler Clip - Figure 1: Standard Sprinkler Wrench 05118CW!B S Form No. F051393 Rev 15.1 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Spri nkler Teniperature Sprink1er Nomnai . Mamurn Ambient B I U 0 0 r Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 C) 100 °F (38 °C) Orange Ordinary 155 °F (68 C) 100 °F (38 °C) Red Intermediate 175 °F (79 C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester3, Black Polyester', and ENT Corrosion-Resistant Coatings4: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT sprinklers, all exposed surfaces and the waterway are coated, but note that the spring is exposed. p _ _______ ç.• . U'.. 1.. Step 1: Carefully slide the L, wrench sideways around the deflector, ensuring en- gagement with the sprinkler ' wrench flats. . Pendent Sprinkler Sprinkler wrench 13577W/B must be used for installing wax coated sprinklers. A 1/2" ratchet is required Step 2: Carefully press the wrench upward and (not available from Viking) ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 11663W/B for Recessed Pendent Sprinkler VK534 S S Page 4 of 6 STANDARD/QUICK RESPONSE sJII(IF1cJ® EXTENDED COVERAGE PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approvahaç1 (UL) SR'QREQPendent&pnnk1erV$c534 4 -' 140 jArx"t 44 '. _4 - Sprinkler Base L NPT Thread Size Nominal K-Factor Maximum Water Overall Length Part Number' SIN Working Pressure Inches mm U.S. metric' Inches mm 08340 Pendent VK534 3/4 20 11.2 161.3 175 psi (12 Bar) 2-5/16 59 Minimum Water Supply Requirements" Listings and Approvals3 Max. Sprinkler Maximum (Refer also to UL Design Spacing (Lx W7) Area per Sprinkler Criter1a Light Hazard Ordinary Hazard Group I Ordinary Hazard Group II Flow! Pressure Flow! Pressure Flow! Pressure cULus' Standard Response 16 ft. x 16 ft. (4.9 256W (23.8 38 gpm @ 11.5 psi 51 gpm @20.7 psi Clx, Dlv', D2Z, C2W m 4.9 m) m') - (143.9 Umin @ 3 Bar) (193.1 Umin r 1.43 Bar) 16 ft. x 18 ft. (5.5 324 ft' (30.1 49 gpm @ 19.1 psi 65 gpm @33.7 psi C1X DIY D2Z 2 m 5.5 m) m2) (185.5 Umin @ 1.32 Bar) (246.1 Umin @2.32 Bar) 20 ft. x 20 ft. (6.1 400 ft' (37.2 60 gpm @28.7 psi 80 gpm @ 51.0 psi C1X, D1Y, D2ZC2 m 6.1 m) m2) - (227.1 Umin @ 1.98 Bar) (302.8 Umin @3.52 Bar) Quick Response 12 ft. x 12 ft. (3.7 144 ft' 30 gpm @7.2 psi 39 gpm @ 12.1 psi E E22 lv' m 3.7 m) (13.4 m2) - (113.6 Umin @.50 Bar) (147.7 Umin @.84 Bar) 14 ft. x 14 ft. (4.3 196 ft' 30 gpm @7.2 psi 39 gpm @ 12.1 psi ElY E2Z m 4.3 m) (18.2 m2) (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 16 ft. x 16 ft. (4.9 256 ft' (23.8 30 gpm @7.2 psi - - B1Y F2Z m 4.9 m) m') (113.6 Umin @ .50 Bar) 18 ft. x 18 ft. (6.5 324 ft' (30.1 33 gpm @8.7 psi (124.9 U - - B1Y F2Z m 5.5 m) m2) mm @ .60 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 40 gpm @ 12.8 psi (151.4 - - A1Y G2Z m 6.1 m) m2) Umin @.88 Bar) Approved Temperature Ratings Approved Escutcheons A- 135'F (57'C) and 175 "F (79 "C) W - Standard surface-mounted escutcheons only B - 135 "F (57 "C), 155 "F (68'C), and 175 "F (79 "C) Approved Finishes X - Standard surface-mounted escutcheons or the Micro-fast5 C - 155 ¶ (68 "C), 175 "F (79 "C), 200 "F (93 "C), and - Brass, Chrome, White Polyester, and Black Model F-i Adjustable Escutcheon "F "C) 286 (141 Y - Standard surface-mounted escutcheons or the Microfast5 D - 155 "F (68 "C), 175 "F (79 "C), and 200 "F (93 "C) Polyester 2- ENT6 Model F-i Adjustable Escutcheon, or recessed with the E - 155 ¶ (68 "C) Micromati Model E-1, E-2, or E-3 Recessed Escutcheon F - 155 ¶ (68 "C), and 175 "F (79 "C) Z - Standard surface-mounted escutcheons or the Micromatic G - 175 "F (79 "C) Model E-1 Recessed Escutcheon. Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. cULus Listed for use in the U.S. and Canada. To determine "Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the "Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10-6" x 13-0" sprinkler spacing, provide the "Minimum Water Supply Requirement" listed in the chart for 14-0" x 14-0" spacing. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" in the appropriate hazard group for the nest larger area listed. The distance from sprinklers to walls shall not exceed one-half the "Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement" used. 6 cULus Listed as corrosion-resistant. Form No. F_051393 Rev 15.1 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESIGN CRITERIA UL - (Also re(r to Approv'aI Chart 1,) cULus Listing Requirements: EC-ELO Pendent Sprinkler VK534 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers as indicated below: The minimum water supplies and maximum areas of coverage shown in Approval Chart 1 are designed to provide the following design densities: 0.10 gpm/ft2 (4.1 mm/mm) for Light Hazard densities; 0.15 gpm/ft2 (6.1 mm/mm) for Ordinary-Hazard Group I densities; 0.2 gpm/ft.2 (8.1 mm/mm) for Ordinary-Hazard Group II densities. The sprinkler installation rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. Viking EC-ELO Pendent Sprinklers are cULus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. Ceiling slope not to exceed 2/12 (950)• Also. Viking ECOH-ELO Pendent Sprinkler VK534 Is sDecificallv cULus Listed for Ordinary Hazard Occupancies: For non-combustible obstructed construction within trusses or bar joists having non-combustible web members greater than 1" (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under Obstructions to Sprinkler Discharge Pattern Development". For installation under concrete tees when installed as follows: The stems of the concrete tee construction must be spaced between 3 It (0.9 m) and 7 ft-6 in (2.3 m) on center. The depth of the concrete tees must not exceed 30 in (762 mm). The maximum permitted concrete tee length is 32 It (9.8 m). However, where the concrete tee length exceeds 32 It (9.8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 ft (9.8 m). The sprinkler deflector is to be located in a horizontal plane at or above 1" (25.4 mm) below the bottom of the concrete tee stems. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages ECI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_051393 Rev 15.1 Ceiling Opening Size: 2-516/" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 3/4,, (20 mm) NPT L( 1-1/2" 38 mm) Mm. Installed with a Microfast Note: At maximum, adapter is Model F-I Adjustable exposed 112" (12.7 mm) from Escutcheon face of ceiling 2-3/8" (60 mm) 1-1/2" (38 mm) Installed with a standard 1/8" surface-mounted escutcheon Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 1/8" 6 mm) Min. + '- Page 6 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE 'tj II(JI1G® PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon (54 mm) A T 1-3/4" (44.6 mm) '4 Max. -. V Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons Form No. F051393 Rev 15.1 Fie • 1: I I Data eet FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6 receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In mm In mm In mm lbs /ft kg/rn CRR LIft 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 11/8 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 548 .109 2.77 264 1 3.93 4.7 37 2% 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 828 .120 3.05 4.34 6.46 2,6 19 4 4.500 114,3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 - 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In mm In mm In mm lbs [ft kg/rn CRR Lift 1 1,315 334 .1.049 266 133 338 168 250 100 70 1¼ 1.660 422 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1,S 1.900 483 1.610 409 145 368 272 405 100 44 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). (9 C@ < APPROVED I PROJECT CONTRACTOR:DATE ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: iJ BLACK HOT-DIP GALVANIZED S ()(EjTj t I• .4) hs eaiOad Tube .JiCsFEEL GROW' Table A Pressure-Temperature Ratings SIZES General Dimensions In Inches These dimen- sions apply to both straight and reducing fittings. S SECTION 2 Extra Heavy Malleable Pipe Fittings Class 300 - (A.A.R.) Ward Class 300 Malleable Iron Fittings are designed to handle higher pressures and more rugged service than our Class 150 fittings. Like all of Ward's fittings, Class 300 fittings are made with the most sophisticated metallurgical and processing controls available. Ward's quality assurance program ensures that the iron is made with high quality raw materials and processed according to rigorous standards. Iron samples are continuously analyzed to ensure that a close grained, high strength, non-porous iron is produced. Ward starts with high quality iron, then accurately machines threads that comply with the precise standards developed by the American Society of Mechanical Engineers (ASME) and published as an American National Standard. The threads have an accurate form, thread length and straightness to allow them to easily engage thread pipe. In addition, Ward fittings have a chamfered opening to allow faster and easier pipe engagement. This feature also protects the fitting threads from damage during handling. NPS 0.0. 01 Bands Thread Length (mm) 1/4 0.93 0.43 3/8 1.12 0.48 1/2 1.34 0.56 3/4 1.62 0.62 1 1.93 0.75 11/4 2.37 0.84 11/2 2.68 0.87 2 3.28 1.00 3 4.62 1.93 Temp. F PSI Size 1/4-1 Size 11/4-2 Size 21/2-3 -2010 150 2000 1500 1000 200 1785 1350 910 250 1575 1200 825 300 1360 1050 735 350 1150 900 650 400 935 750 560 450 725 600 475 500 510 450 385 550 300 1 300 300 S 17 MALLEABLE _IRON _90 0 STRAIGHT ELI CLASS 300 NPS Center to End Outside Dia. of Band B(min) Length of Threads C(min) Take out k A - . c 4 I 1.80 064 0.89 11/4 194 11/2 213 268 087 1.40 2 2.50 3.28 1.00 1.74 21/2 2.94 3.86 1.17 3 1 3.38 1 4.62 1 1.23 2.18 4 1 - - - - MALLEABLE IRON _REDUCING __9fl0 ELI CLASS 300 NPS to Center End A to End Center B Outside nd C(min) Outside Dia.of Band D(min) Length of Threads E(min) ThreadsB Length of Take out Take Out F(niin) B j _ E 3/8x1/4 1/2x3/8 1.19 1.19 1 1.34 1.12 0.57 0.47 0.65 0.78 3/4 x 1/2 1.31 1.38 1.63 1.34 0.64 0.57 0.76 0.84 1 x3/4 1.50 1.56 1.95 1.63 0.75 0.64 0.81 1.01 lx 1/2 - - - - - - 11/4x1 11/4 x - - - - - 11/2 x 11/4 - 11/2x1 - - - - - - - - 2 x 11/2 2x11/4 - - - - - - - - MALLEABLE IRON 90° STREET ELL CLASS_300 Center Center Outside Port Dia. Length of Length of Take Out Take t NPS to End to Male Dia.of Band Male End Internal Threads External Threads r Female C(min) D(max) E(min) F(min) 1/4 0.94 1.44 0.93 0.26 0.43 0.40 1.03 0.53 3/8 106 163 112 036 047 041 122 065 1/2 1.25 2.00 1.34 0.49 0.57 0.53 1.46 0.71 3/4 1.44 2.19 1.63 0.67 0.64 0.55 1.64 0.89 1 1.63 0.25 1.95 0.88 0.75 0.68 0.42 1 0.94 11/4 1.94 2.88 2.39 1.16 0.84 0.71 2.17 1.23 B 11/2 2.13 3.13 2.68 1.35 0.87 0.12 2.40 1.40 F 2 2.50 3.69 3.28 1.75 1.00 0.16 2.93 1.74 II iIJ fl S S H MALLEABLE .IRON.45° ELI CLASS 30:0 Center NPS Outside Diaof th of lake to End A Band Threads C (mm) Out DI l • I A 1/4 0.81 0.93 0.43 0.40 / "Ilk cX fi. F •. B . .. ' 3/8 0.88 1.12 0.47 1/2 1.00 1.34 0,57 0.46 3/4 1.13 1.63 0.64 0.58 1 1.31 1.95 0.75 0.62 . . 11/4 1.50 2.39 0.84 0.79 11/2 1.69 2.68 0.81 0.96 '':• - -- 2 2.00 3.28 1.00 1,24 21/2 - - - - 3 - - - - 4 - - - - MALLEABLE_IRON_450_STREET_ELI CLASS 300 NPS Center Center Outside Dia.of . Port Dma. Internal I.engtiiof External Length of Take Take to End A to End B Band C(n)Dh1 Male Threads Threads Out Out ,. E(min) F(min) 1/2 3/4 )LI MALLEABLE___IRON STRAIGHT TEE CLASS 300 NPS Center to End A Outside ma. of Band B(mmn) Length of Threads C(min) Take Out I .' . 11 t-A A ' . L____ ] B ri 0.53 0.11 0.89 1/4 0.94 0.93 0.43 3/8 1.06 1.12 0.47 0.65 1/2 1.25 1.34 0.57 3/4 1.44 1.63 0.64 1 1.63 : 0.94 1 1/4 1.94 11/2 2.13 2.68 0.87 1.40 2 2.50 3.28 1.00 1.74 21/2 - - - - 3 3.38 1 4.62 1.23 2.18 4 - - - - iI MALLEABLE IRON REDUCING TEES CLASS 300 NPS Center to End A Center to End Center to End , Outside Die. of Band D (mm) Outside Die. of Band 02 (mm) Outside Die'of Bad n D3 (mm) Length of Threads L ,mu . n, Length of Threads min, Length of Threads E. min, Take Out Take Out Take Out 314x 3/4 x 1/2 1.31 1.31 1.38 1.63 1.63 1.34 0.64 0.64 0.57 0.76 0.76 0.84 3/4 x 3/4 x3/8 - - - - - - - - - - - - 3/4 x 3/4 x 1/4 - - - - - - - - - - - - 3/4 x 1/2 x 3/4 - - - - - - - - - - - - 3/4x112x1/2 - - - - - - - - - - - - lxi x3/4 1.50 1 1.50 1.56 1 1.95 1.95 1.63 0.75 0.75 0.64 0.81 0.81 1.01 1 x x 1/2 1.44 1.44 1.50 1.95 1.95 1.34 0.75 0.75 0.57 0.75 0.75 0.96 lxlxll4 - - - - - - - - - - - - 1x3/4x1 - - - - - - - - - - - - 1x3/4x3/4 - - - - - - - - - - - - 1x1/2x1 - - - - - - - - - - - - 1 1/4x 11/4 x 1 1.75 1 1.75 1.81 1 2.39 2.39 1.95 0.84 0.84 0.75 1.04 1.04 1.12 1 1/4 x 11/4 x 3/4 1.63 1.63 1.75 2.39 2.39 1.63 0.84 0.84 0.64 0.92 0.92 1.20 11/4x11/4x1/2 - - - - - - - - - - - 11/4xlxl - - - - - - - - - - - - 11/2x11/2x11/4 - - - - - - - - - - - - 1 1/2x I i/2x 1 1.81 1 1.81 2.00 1 2.68 2.68 1.95 0.87 0.87 0.75 1.08 1.08 1.31 11/2 x 11/2 x 3/4 1.69 1.69 1.88 2.68 2.68 1.63 0.87 0.87 0.64 0.96 0.96 1.33 11/2 x 11/2 x 1/2 1.63 1.63 1.81 2.68 2.68 1.34 0.87 0.87 0.57 0.90 0.90 1.27 2x2x 11/2 2.25 2.25 2.38 3.28 3.28 2.68 1.00 1.00 0.87 1.49 1.49 1.65 2x2x11/4 - - - - - - - - - - - - 2 x 2 x 1 2.00 1 200 225 3.28 3.28 1.95 1.00 1.00 0.75 1.24 1.24 1.56 2 x 2 x 3/4 1.81 1 1.81 2.13 3.28 3.28 1.63 1.00 1.00 0.64 1.05 1.05 1.58 2x2x1/2 1.75 1.75 2.06 3,28 3.28 1.34 1.00 1.00 0.57 0.99 0.99 1.52 2x11/2x2 - - - - - - - - - - - - 21/2x21/2x2 - - - - - - - - - - - - 21/2x21/2x11/2 - - - - - - - - - - - - 3x3x2 1 2.81 1 2.81 3.13 4.62 4.62 3.28 1.23 1.23 1.00 1.61 1 1.61 2.37 D3 j cl F S 0 S MALLEABLE IRON STRAIGHT COUPLING CLASS 1. 300 NPS Length of Outside pa. of Length of Take Coupling A (mm) Band Threads C (mm) Out B(min) t.:II1i . :: •. --- 0.28 050 1/4 1.37 0.93 0.43 0.57 0.40 1 237 195 075 11/4 2.87 2.39 0.84 073 11/2 2.87 2.68 0.87 0.71 2 3.62 3.28 1.00 1.05 21/2 - - - - 3 - - - - _MALLEABLE _IRON _REDUCING COUPLING CLASS 300 NPS Length of Coupling g Outside Dia. of Band Small End B (mm) Outside Dia. of Large End B2 (mm) Length of Threads Small End C(min ) Length of Threads Large End C2 (mm) Take Out Take Out - .• -. " . •.: C A C2 __ B2 0.44 -Et' 0.51 3/8 x 1/4 1.44 0.93 1.20 0.43 0.47 0.31 0.32 1/2 x 3/8 1 1.69 1.12 1.34 0.47 0.57 0.31 0.44 1/2x 1/4 1.69 0.93 1,34 0.43 0.57 031 3/4x 1/2 1.75 1.34 1.63 0.57 0.64 0.33 0.34 3/4x3/8 - - - - - 3/4 x 1/4 1 x3/4 1 2.00 1.63 1.95 0.64 0.75 0.32 0.45 1 x 1/2 2.00 1.34 1.95 0.57 0.75 0.32 0.47 1x3/8 - - - - - - 1x1/4 - - - - - - - 11/4 x 1 2.38 1.95 2.39 0.75 0.84 0.48 1 1/4x 3/4 1 238 1.63 239 0.64 034 0.48 0.64 1 1/2x 11/4 2.69 2.39 2.68 0.84 0.87 0,62 0.64 11/2 x 1 2.69 1.95 2.68 0.75 0.87 0.62 0.66 1 1/2x3/4 69 L63 68 034 037 032 030 11/2x1/ 2x1 1/2 3.19 2.68 3.28 0.87 1.00 0.84 0.87 2x 1 1/4 3.19 2.39 3.28 0.84 1.00 0.84 0.89 2x 1 3.19 1.95 3.28 1 0.75 1.00 0.84 0.91 2x3/4 - - - - - - - 2x1/2 - - - - - - - 21/2x2 - - - - - - - 2 1/2 x 1 1/2 - - - - - - - 3x21/2 - - - - - - - 3x2 - - - - - - - 3x11/2 - - - - - - - 40 - - - - - - - 4x2 21 S MALLEABLE PIPE CAPS CLASS 300 _IRON NPS Overall Length of Height A Band B (mm) Threads C (mm) 0.43 1/4 0.78 0.93 098 134 0.57. 3/4 108 163 064 B -..- 1 1.26 1.95 0.75 1 1/4 1.38 2.39 0.84 11/2 1.43 2.68 0.87 2 1.68 3.28 1.00 21/2 - - - 3 - - - MALLEABLE CROSS CLASS 300 _IRON NPS Center t: End A (mm) Outside Dia. of Band B(min) Length of Threads C (mm) Take Out A A j 1.40 3/4 1.44 1.63 0.64 0.89 0.94 ! 1.23 1 1/2 2.13 2 250 328 100 174 S S RA 9 I .WARD UNIONS S Rugged-Strong Made of the Best Quality Malleable Iron S Extra heavy brass seat ring accurately machined to insure perfect seating under difficult conditions. Suitably Chamfered Rust Resistant Treatment Properly Threaded Continuous, careful inspection during each manufacturing operation. TYPES AVAILABLE Class 150 Brass-to-Iron Class 250 Brass-to-Iron Class 300 Brass-to-Iron Class 150 All Iron Seat Class 300 All Iron Seat Class 150 Gasket Unions Class 300 Brass-to-Brass Class 150 Di-Electric Unions (Female iron pipe to sweat copper) 23 fl S S SECTION 3 QUALITY PIPE UNIONS Throughout the entire manufacturing process of WARD unions, special emphasis is placed upon the control and accuracy of each operation. WARD unions are made from closely grained, high tensile iron and are produced under expert laboratory supervision. Modern methods of foundry practice and carefully supervised molding are combined to produce castings that are smooth and clean in every respect and free from imperfection. WARD unions are manufactured in strict accordance with the requirements for threaded pipe unions standard, developed by American Society of Mechanical Engineers (ASME) and published as an American National Standard. Each opening is chamfered permitting easy assembly. WARD unions make up easily and pull tight for a sealed assembly. Continuous and careful inspection by trained employees during and after each operation produces quality products which will give satisfaction to the user. PSI Temp.F Class 150 Class 250 Class300 -20 to 150 300 500 200 265 455 550 250 225 405 505 300 185 460 460 350 150 315 415 400 110 270 370 450 75 225 325 * 180 280 H500 550 * 130 230 &ti1 13fl&D j!W 1JflD fIftiu1J 24 S S S WARD UNION BRASS TO IRON SEAT CLASS 150 I NPS Overall Length A(min) Length of Threads B(min) Thru Hole C(min) Width of Nut D(min) . -. . . . .3 ,,,j tL.i.Ji -..• I -... 110 126 145 1.71 1/8 1.26 0.30 0.21 0.93 1/4 144 032 036 3/8 161 036 052 1/2 172 043 061 3/4 1.94 0.50 0.80 3/4 X12 1.94 050 171 1 206 058 100 207 11/4 2.26 0.67 1.31 2.50 11/2 2.41 0.70 1.55 2.82 2 2.75 0.75 2.03 3.41 21/2 3.22 1 0.92 2.38 4.12 3 3.50 1 0.98 3.00 4.75 *4 3.85 1 1.08 4.03 6.00 *UL Standards not applicable to 4" size union WARD UNION BRASS TO IRON SEAT CLASS 250 NPS Overall Length A(min) Length of Threads B(min) Thm Hole C(min) Width of Nut D(min) . .... L........... - 1.26 1.71 257 2.89 1/8 1.26 : 0.93 1/4 1.11 3/8 1.71 0.47 0.42 1/2 1.18 0.57 0.54 1.45 3/4 207 :o 074 1 2.31 0.75 0.95 2.07 11/4 262 0.84 1.27 127 11/2 1 2.78 0.87 1.50 2 3.31 1.00. 1.93 3.48 21/2 3.52 1.17 2.32 4,15 3 3,84 - .23 1 2.90 1 4.69 *4 4.39 1.33 1 3.82 1 6.47 UL Standards not applicable to 4" size union WARD UNION BRASS TO IRON SEAT CLASS 300 .. . I NPS Overall Length A (mm) Lengthof Threads B (mm) Thm Hole C (mm) Width of Nut D (mm) C - A -.--. 266 2.85 1/8 1.26 0.30 0.21 1.26 1 1 0 0 1 3/4 2.12 0.64 0.74 2.12 1 2.31 0.75 0.95 2.66 266 2.31 11/4 084 127 1 1/2 2.85 0.87 1.50 2 2.23 1.00 1.93 3.23 21/2 3.33 1.17 1 2.320 1 3.33 3 4.09 1.23 2.90 4.09 4 - - - - 25 Set Screw and Locknut Included Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2'13 rod sizes, and /8'-11 rod sizes Fig. 65XT - /8'-16 rod size (see below) u\zyva u$TEo S Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" 119.Omml. Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /-16 rod will support 1/2" 115mml thru 4" llOOmml pipe 1/2"..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. ImmI 65.1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 55.5/0 5/81111 11/2" (38.1) 3/4" (19.0) 1" (25.4) 9/16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 65.1/2 11/4" (31.7) 55 (24.9) 55.5/8 11/4" (31.7) 55 (24.9) Fig. 65XT-318 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" 1100mml pipe. Set Screw and Designed to meet or exceed requirements of Locknut Included FM DS 2-0. >1 LISTED 19/is' 139M J65 ) Th21 (34.9) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions S 13 B-Line S S S Beam Clamps Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap ®TOLCO Size Range: 3/8-16 & 1/2 .13 rod Component of State of U 4(101,6mm) thru 16" (406.4mm) lengths California OSHPD Approved Note: longer lengths are available consult factory Seismic Restraints System two Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore the beveled locking slot of the Fig. 69R will provide a secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Finish: Pre-Galvanized Order By: Figure number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) For Use With: Any B-Line or TOLCO beam clamp. * Patent #5,947424 Slot Width Length Part No. in. (mm) 69R-3/8-L /16" (30.1) Specify 69111-1/2-1. 9/16" (30.1) Specify Ll All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B Line Fire Protection Solutions 17 by E1'4tI Fig. 2005 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3170NF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8' (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general p:ping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" 150mm1) Flared edges ease installation for all pipe - types and protect CPVC plastic pipe from abrasion. Captured design - - - keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before before installation. Adjusting nut is easily removed. ' 7 Approvals: Underwriters Laboratories listed 11/2 (15mm) thru 8 (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" l200mml). Fi.20O-110200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F 1343°Cl Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FMDS2-0. . -. Fig. 200C Fig. 200F [7: Adak Fig. 200 A B Fig. 200-1h.. 200-3/4 Fig. 200-2' to 200-8 Part No. Pipe Size in. (mm) Rod Size in. A (mm) in. B (mm) Approx. Wt./100 lbs. (kg) 200-1/2 1/2" (15) /o"-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-/4 3/4" (20) /t"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1' (25) 3/o°-16 3/8" (857) 2/e" (66.7) 12 (5.5) 200-11/4 11/4" (32) /"-16 33/4" (94.0) 21/0" (73.0) 13 (5.9) 200-11/2 11/2° (40) /o"-16 3/8° (98.4) 21/8" (13.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3' (76.3) 15 (6.9) 200_21/2 21/2' (65) I8"-16 5/8" (142.9) 41/0" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 57/8" (149.1) 4' (101.6) 29 (13.3) 200_31/2 31/2" (90) /o"-16 7 /8" (187.3) 51/4" 1133.31 34 (15.6) 200-4 4' (100) /8"-16 73/8" (101.3) 5" (121.0) 35 (16.0) 200-5 (125) 1/f13 51/80 (231.8) 51/4" (158.7) 66 (30.2) 200-6 (150) 1/2"13 101/8' (257.2) 6/4" (111.4) 73 133.41 200-8 8" (200) 1/f-13 131/8" (333.4) 8/4° (222.2) 135 (62.3) S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. - B-L ine Fire Protection Solutions 21 by ET4 Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** ®TOLCQ Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2 (50mm) CPVC pipe usv Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom - - - ofabeam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge l0.912mml steel using (2) 1/4" x V tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and II ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with I a hex socket attachment be used as installation tools. No impact I tools (such as a hammer) are allowed. Damage has been known to ,_ result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. B Finish: Pre-Galvanized Order By: Figure number and pipe size A * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. * * With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (ml in. (mm) Lbs. (kg) 24-/4 3/4" 1201 2/i&" (58.1) 1/32" (27.8) 1/1" (30.2) 51/2 (1.67) 5/1s" (7,9) 9 (4,1) 24-1 1" (25) 2/8" 166.11 1/16" (33.3) 1/16" (30.2) 6 (1.83) /tt" (1.9) 9 (4.1) 24-1/4 11/4" (32) 3" (76.2) 11/2" (38.1) 1/16" (30.2) 61/2 (1.98) s/is" (7.8) 11 (5.0) 24-11I2 11/2" (40) 31/4" (82.5) 1/8" (42.3) 1/16" (30.2) 7 12.131 /16" (1.9) 12 15.41 24-2 2" (50) 311/15" (93.7) 122/32" (43.6) 13/16" (30.2) 8 (2.44) /ts" (7.9) 15 (6,8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4" (20mm) thru 2" (40mm) pipe [jJ r1' LISTED Material: - Pre-Galvanized Steel .. Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is f •/ I easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13 2010 edition 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel .. pipe or CPVC plastic Pipe Approvals: — Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). f - Finish Pre Galvanized Order By Figure number and band hanger, size from 3/4 l20mml thru 2 (40mm) . Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless Otherwise specified. B—Line by E T4tJ 38 Fire Protection Solutions Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right & left hand threads) Size Range: /8"-16 thru 3-4 rod Material: Steel TI Function: Recommended for use as a hanger support in hanger assemblies. Specify length Rod is threaded on both ends with right hand threads of the length shown. Also -' available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°Cl TL Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and A materials, "' ".__ Thread Size Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length IL 650°F (343°C) 150°F (399°C) Part No. A in. mm) Lbs. (kN) Lbs. lkNl B3205-3/s x 1 /8-16 21/2' (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x 1/2 .13 21/2' 63.5) 1350 (6.00) 1057 (4.70) 83205-5/ex 1' /-11 2112" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x 1' /4-10 3 (76.2) 3230 (14.37) 2530 111.251 B3205-1/ex L 7/°_9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8'-16 thru 11/2"-6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. & Size Threads Per Inch Recommended Load Lbs. (kN) Approx. Wt./100 R. Lbs. (kg) AIR 1I4 x 'L' 20 240 (1.07) 12 (5.44) AIR 3/g" x 'L' 16 730 (3.24) 29 (13.15) AIR /2" x '1' 13 1350 (6.00) 53 (24.04) AIR 5/g" x'1' 11 2160 (9.60) 89 (40.37) AIR 3/4" x'1' 10 3230 (14.37) 123 (55.19) AIR 1/8° x'1' 9 4480 (19.93) 170 (17.11) For larger sizes consult full line pipe hanger catalog BLine by T4J All dimensions in charts and on drawings are i, inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Fire Protection Solutions All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. S - 86 Fire Protection Solutions S B-tine by E.t4U Upper Attachments S Fig. 75 - Swivel Attachment Size Range: - /8'-16 Rod Attachment Material: Steel Function: Recommended applications for this product: May be used as a Branch Line Restraint for structural attachment to anchor bolt, beam clamp, etc. May be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2010) 9.1.2.6. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support up to 4 IlOOmmI pipe. Finish: Electro-Galvanized Weight: Approx. Wt./100 - 13.3 Lbs. (6.okg) Order By: Figure number Patent: #7,887,248 I Fig. 78 All Steel Ceiling Plate Fig. 75 Swivel Attachment Fig. 200 All Threaded Rod "Trimline Adjustable Band Hanger Fig. 25 Surge Restrainer May be used as a structural attachment component of a branch line restraint V .-.-- Fig. 65XT Reversible Beam Clamp W-Beam Fig. 75 Swivel V Attachment All Threaded Rod Maybe used with a pitched roof application, to meet requirements of NFPA 13 010) Sec. 9.1.2.5. Set Bolts & Hardware Included Seismic Bracing Fig. 825 - Bar Joist Sway Brace Attachment To Steel Size Range: One size accommodates all Fig. 900 Series sway brace attachments. Maximum Horizontal Design Load 2015 lbs 18.96kNl. : . Material: Steel Function: To attach sway bracing and hanger assemblies to steel members. Features: This product's design incorporates a concentric attachment point which is critical to the performance of V - structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist, Break off head set bolt design assures verification of proper installation torque (mm. 31 ft-lbs.). Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL.). For FM Approval information refer to page 57. Installation Instructions: Fig. 825 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, bracing pipe" and a TOLCO braced pipe" attachment, to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 825 on the steel beam, tighten the cone point set bolts until heads break off. Attach other TOLCO transitional attachment fitting, Fig. 980, 910, 909, or any other TOLCO approved transitional fitting. Transitional fitting attachment can pivot for adjustment to proper brace angle. ®TOLCO C® UI. LiSTED; Maximum Design Load 2015 lbs. (&96kNl UL Listed as Hanger Attachment for 6 1150mni) Pipe at Maximum Spacing Finish: Plain, Electro-Galvanized and HDG Approx. Wt./100: 247.5 Lbs. 1112.2kg1 Order By: Figure number and finish US Patent #6,098,942, Canada Patent #2,286,659 Fig. 825 Fig. 980 Shown with Fig. 910 Fig. 825 Side View Shown with Fig. 910 Fig. 825 / Fig. 1000 I-Beam Brace S / ------------- (25.4mm) 1/2" Bolt & Nut Furnished Top View Max. Bar joist shown attached 6' 1152.4mm1 to various roof material\ 'Shown with Fig. 910 May pivot in any direction Front View Eaton's B-Line Business seismic bracing components are designed to be compatible on with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown ir parentheses are in millimeters unless otherwise specified. B-L•ine 56 Fire Protection Solutions by S 1I1 K Set Bolt Included Mourning Hardware Is Not Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 66 Fire Protection Solutions S B-line by WT4U Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" Size Range: One size fits bracing pipe 1" (25mm) thru 2" (50mm), B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31.7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUl). For FM Approval information refer to page 67. Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002, 4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel, Contact B-Line for alternative finishes. Order By: Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Fig. 41 Fig. 980 Longitudinal Brace Part Mtg. Hdw. Mounting Hole Max. Design Approx. Number Size A B D Load (cULus) Wt/100 in. (min) in. (mm) in. (mm) in. 1mm) in. (mm) lbs. (kg) 980-/8 /" (9.5) 51/4" (133.3) 11/8" (47.6) 13/32" (10.3) 2015 (8.96) 149 (67.6) 980.1/2 * 1/2" (12.1) 51/4" (133.3) l/t" (47.6) 17/32" (13.5) 2015 (8.96) 148 (67.1) 980- /t" (15.9) 51/4" (133.3) 17/8" (47.6) 11/16" (17.5) 2015 (8.96) 147 (66.7) 980-/4 3/4" (19.0) 51/4" (133.3) 1/8" (47.6) 13/16" (20.5) 2015 (8.96) 146 (66.2) Standard size Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. k c®Us LISTED S Seismic Bracing Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 1' (25mm) thru 8' (200mm) IPS. Pipe size used for bracing: 1' (25mm) and 1/4' (32mm) Schedule 40 IPS. Material: Steel ' Function For bracing pipe against sway and seismic disturbance The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1' (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA (UI) and Canada (cUl). For FM Approval information refer to page 71. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4 )32mm)), and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Pipe Size in. (mm) Part Number & Approx. Wt./100 1" 124mm) Brace Pipe lhl( (32mm) Brace Pipe Lbs. (kg) Lbs. (kg) Design Load - Lbs. For Brace Pipe Size 1"! 11/4" Sch. 7 Sch. 10 Sch. 40 1" I V/C 1"/ 11/4" 1" / 11/4" (25) 1001-1 X 100.0 (45.3) 1001-1 X 11I4 118.0 (53.5) -- I -- 1000 / 1000 1000 /1000 11/4" (32) 1 1001.11/4 X 100.0 (45.3) 100111/4 X 1/4 114.0 (51.7) -- I -- 1000 / 1000 1000/1000 11/2" (40) 1 1001.11/2 X 100.0 (45.3) 1001-1'/2 X 11/4 115.0 (52.1) -- / -- 1500./1500 1500/1500 (50) 1001-2 X 108.0 (49.0) 1001-2X 11/4 121.0 (54.8) -- / -- 2015/2015 2015/2015 21/2" (65) 1001.21/2 X 1 138.6 (62.8) 100t-2/2 X 11/4 160.4 (72.7) 1600/1600 2015/2765 2015 /2765 (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 1600 ,' 1600 2015 /2765 2015 /2765 (100) 1001-4X1 160.9 (73.0) 1001-4X1'/4 182.4 (82.7) 1600/1600 2015/2765 2015/2165 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 1600 1600 2015 /2765 2015/2765 8" (200) 1001-8 X 211.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 1 1600 / 1600 2015/2765 2015/2765 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by 70 Fire Protection Solutions S Q Channel Selection 1 UNISTRUT CHANNEL SELECTION CHART Channel Dimensions Material & Thickness Hole Pattern les Channel Height Steel Steel Alum. Stainless Width HS I KO SL DS H3 In (mm) In (mm) gauge gauge In (mm) Steel Only P1000 1% '41.3) 1%(41 'I) 12 ga 12 ga 0.109i28 U U U U U U U P1100 1%(413) 1%(413) 14 ga 14 ga - U E U 0 - - P2000 15A (41.3) 1%(413) 16 ga - - U U U U U - - P3000 1% (41.3) 1%(34.9) 12 ga I - - U U U - - P3300 15A(41.3, 7A (22.2) 12 ga 12 ga - U U U P4000 15A 141.3 % (20.6) 16 ga 16 ga 0.078 (2,0) • a U - • - - P4100 1% (41.3 %(206) 14 ga - - U U - - - 04400 1%41.3 1(25.4 12 ga - - U P4520 1%(41.3) %(20.6) 12ga - - . ________ • - - - P5000 1%(41.3) 3¼'82,6 12 ga 12 ga - U U 0 - I P5500 15A (41.3) 2/i (61.9,) 12 ga - 0.109 (2.8) U U U 0 - - CHANNELS & COMBINATIONS IN DESCENDING ORDER OF STRENGTH S S Area Weight I $ Allow. Moment Channel In2 (crn) Ibs!ft (kg/rn) In' (am") 1n3(cm') In-lbs (N-th) 1.793 6.10 6.227 1.916 48,180 9.1 259.2 31.4 5.440 1.965 6.68 4.068 1.669 41,980 P1004A 12.68 9.9 169.3 27.4 4,740 1.452 4.94 2.805 1.151 28,940 P5501 9.37 7.3 116.8 l8.9 3.270 2.221 7.55 1.856 1.142 28,720 121001C41 14.33 11.2 77.2 18.7 3,250 0.897 3.05 1.098 0.627 15,7.70 P5000 578 45 457 10.3 1,781.0 1,111 3.78 0.928 0.571 14,360 P1001 1 7.16 5.6 38.6 9.4 1,620 0.835 2.84 0.733 0.451 11,340 P1101 5.39 4.2 30.5 7.4 1,280 1.000 3.40 0.591 0.430 10,810 P3001 6.45 5.1 24.6 7.0 1,220 0.726 2.47 0.522 0.390 9,820 P5500 468 3.7 21.7 6.4 1.110 0.684 2.32 0.618 0.381 9,570 P2001 4.41 3.5 25.7 6.2 1.080 0.489 2.23 0.279 0.297 7,480 P9200 3.16 3.3 11.6 4.9 850 0.849 5.77 0.26 0.26 6,410 P4401 .5.48 8.5 10.6 4.2 725 0.609 2.07 0.302 0.242 6,070 1 A1 00 3,93 3.1 12.6 4.0 690 0.387 1.88 0.166 0.205 5,150 P9000 2.50 2.8 6.9 3.4 580 0.555 1.89 0.185 0.202 5,070 000 3.58 2.8 7.7 3.3 570 0.790 2.69 0.176 0.201 5,060 P3301 5.10 4.0 7.3 3.3 570 P4521 0.77 2.62 ' 3.9 0.15 0.18 4,538 4.97 6.1 2.9 513 Combinations not shown in catalog are available on special order. Consult factory for more details. Area Weight I s Allow Moment Channel In2 (cm2) IbsIft (kg/rn) I0 (cm") 1n3(cm4) ln4bs (Nm) P1100 0.418 1.42 0.145 0.162 4,060 2.69 2.1 6.0 2.6 460 P3000 0.500 1.70 0.120 0.153 3,850 3.23 2.5 5.0 2.5 430 101 0.579 1.97 0.117 0.143 3,610 3.74 2.9 4.9 2.4 410 P2000 0.342 1.16 0.125 0.140 3,520 2.21 i,7 5.2 2.3 400 P4001 0.478 1.66 0.104 0.128 3,210 3.14 2.5 4.3 2.1 360 0.459 1.56 0.077 0.103 2,590 A3301 2.96 2.3 3.2 1.7 290 P4400 0.424 2.89 0.053 0.092 2,300 2.74 4.3 2.2 1.5 260 0.305 1.04 0.061 0.086 2,170 At 000 1.96 1.5 2.5 1.4 250 300 0.395 1.34 0.037 0.072 1,800 2.55 2.0 1.5 1.2 200 P4520 0.384 1.31 0.031 0.064 1,615 2.48 1.9 1.3 1.0 183 A400 1 0.264 0.90 0.037 0.058 1,470 1.70 1.3 1.5 1.0 170 P6001 0.213 0.73 0.045 0.055 1,400 1.38 1.1 1.9 0.9 160 0.290 0.98 0.026 0,054 1,360 P41 00 1.87 1.5 1.1 0.9 150 4000 0.244 0.83 0.023 0.049 1,230 1.57 1.2 0.9 0.8 140 0.230 0.78 0.017 0.038 950 .A3300 1.48 1.2 0.7 0.6 110 0.107 0.36 0.009 0.020 510 P6000 0.69 0.5 0.4 0.3 60 0.148 0.50 0.007 0.018 460 P7001 0 0.96 0.8 0.3 0.3 50 0.074 0.25 0.002 0.007 170 P7000 048 0.4 0.1 0.) 20 UNISTRUT Pi000® DF GR HG PG PL I 413 IEI_1 j915 ff k1]23.2 ftA. flw 95{22.2 93 413 ISO 2 2 Wt/100 Ft:189 Lbs (281 kgl100 m) Allowable Moment 5,070 In-Lbs (570 N.m) 12 Gauge Nominal Thickness .105(2.7mm) P1 001 DF GR HG PG PU 0 41.3 F 1 L-HI Wt/100 Ft: 378 Lbs (562 kg/100 m) Allowable Moment 14,360 In-Lbs (1,620 N.m) 12 Gauge Nominal Thickness .105" (2.7mm) P1000 DS P1000143 OR GIR HG PG P1000 HS 111 GR HG PG PL I P1000 KO tGRPGI Slots are 2 1/4"(69.9) x 7A"(22.2)-- W '222 Knockouts . 3 W (88.9) on Center 9As" (14.3) Dia. Holes °AI (14.3) Dia. Holes 6"(152.4) on Center 1 W (47 rj 1W (47.6 Center j 1 Pipe Clamps can be Mounted on Both Sides WI/lOU Ft: 173 Lbs (257 kg/100 m) Wt/100 Fl: 175 Lbs (260kg/100m) WtJ100 Ft: 190 Lbs (283kg/100m) WIJ100 Ft:185 Lbs (275kg/100m) PI000SL E GR HG PG PL I PI000T E.61 DF GR HG KW P1000 WI 1DF GR HG PG PLI Slots are 3'(76.2) x9&(10.3) Slots are Slots are 4" (101.6) on Center 1½" (28.6)0 1e (14.3) 2'(50.8) X 1/16"(17.5) 2" (5C.8) on Center ., 3"(76.2) on Center 13/161, (12.7) (25.4) WI/lOU Ft: 185 Lbs (275 kg/100 m) WIilOO Ft: 185 Lbs (275kg/100m) WtJ100 Fl: 185 Lbs (275kg/100m) CHANNEL NUTS (REFER TO PAGES 7374 FOR DETAILS) 1 SEE PAGE 73, E4] P1006-0832 P1006-1024 P1008T P100611420 mmkiL P1024 P1012S ' P3006-0832 " P3006-1024 ... P3016-0632 P3016-0832 P1006-1420 P1010T T P1023S P3006-1420 P3016-1024 P1007 P3007 P3016-1420 P1008 P3008 P1009 P3009 P1010 P3010 P1024S Channel Finishes: DF, PL, GR, HG, PG, ZD; Standard Lengths: 10'&20' LM CORE PRODUCTS TYPICALLY AVAILABLE FROM STOCKI S S r Channel Nuts With and Without Spring I 11 I 1Ii I [1 S Part Nut Size WtI100 pcs Number Thread Lbs (kg) Use With P1006-0832 #8 -32 7(3.2 P1006-1024 #10 -24 7(a2) P1006-1420 ¼' -20 7(3.2) pi000, P1007 Ym 18 62 7 100, P1008 YB' -16 10(4.5) P3000 P1009 7A6' -14 9(4.1) P1010 ½' -13 12(5.4) Part Nut Size W11100 PCs Number Thread Lbs (kg) Use With P1012S YB' -11 21(9.5) p1000, P1023S 3/4'-102 P1024S W -9 21(9.5) P3000 Part . Nut Size WtJ100 pcs Number .. . Thread Lbs (kg) Use With P4006-0832 #8 -32 7(3,2) P4006-1024 #10 -24 7(3.2 19~ P4006-1420 ¼' j20 7 (3.2) P4007 /16 18 6 (2.7,1 P4400, P4008 3 ,, , -16 . 9(4.1) P4520, P4100 P4009 /16' -14 9(4.1) P4010 ½" -13 8(3.6) Part Nut Size WV100 pcs Number Thread Lbs g) Use With P5506-0832 #8 -32 7(3.2) P5506-1024 #10 -24 7(3.2 P5506-1420 1/4" -20 7(3.2) P5507 %6" - - :1 I7L. -. - P5508 ½" -16 10(4.5 P5509 Vie -14 10(4.5) P5510 ½" -13 12(5.4) ........... I ....... ................................. . .. .... . .............. . . .................. . .... - ..................... . ................ . ................ ... I . ...... 1-1-1. . .......... ........... .............. I"-...-, ....... . ..... . .. .. . ............ 11 ... . ...... . ... ......... . ........ ........ . ............ ....... . ........ I. ................ ....... . ....... CHANNEL NUT WITH SPRING E EG, HG CHANNEL NUT WITHOUT SPRING I EG, HGI S Part Nut Size. Wt/100 PCs Number Thread Lbs (kg) . Use With P3016-0632 #6 -32 2(0.9) P3016-0832 #8 ..2 Any P3016-1024 #10 -24 4(1.6) Channel P3016-1420 ¼" -20 4(1.8) Part Nut Size Wtlloopcs Number Thread Lbs (kg) Use With P3006-0832 #8 -32 6(2,71) 1 P3006-1024 #10 -24 6(2.7) P3006-1420 ¼" -20 6(2.7) Any P3007 /ie' -18 6(2.7) Channel P3008 _i!_ 31V P3009 V16' -14 _ 9(4.1) Any Channel P3010 1,4" - 11 (5. 0) Except P3300, P4000,134400, P4520,P4100 P3300, P3013 1h" -13 8 (3.6) P4000,P4400, P4520,P4100 Part Nut Size Wtf100 pea Number Thread Lbs (kg.) Use With P1012 Ye" 11 20('9.1) Any Channel P1023 -10 20(9.1) . P4000,134400, P1024 7A" -9 20(9.1) P4520,134100 Part Nut Size Wt/100 pea Number Thread Lbs (kg) Use With :1111(5.0,) P3300, P4000, P4023 3A' -10 11(5.0) P4100 Part Nut Size Wtl100pcs Number Thread Lbs (kg) Use With P1006T1420 ¼' -20 7(3.2) Any P1008T ½" -16 10(4.5) Channel Any Channel P10I0T ½" -13 12(5.4) Except P3300, P4000, P4400, P4520,P4100 P3300, P4000, P4010T ½" -13 8(3,6) P4400, P4520, P4100 Part Nut Size W11100 PCs Number Thread, Lbs (kg) Use With P4908 ¼" -16 17.5 (7.9) Any Chanel Double Conveyor Adjusting Nut Part Nut Size WtI100 pea Number Thread Lbs (kg) Use With - P1016 ¼" -16 17.5(7.9) Any Slotted Channel Missing Link Multi-Purpose Strut Fastener [CORE PRODUCTS AVAILABLEFROM STOCK I Kidde ECS Fire Suppression System Component Description FM-200®Fire Suppression Agent FEATURES Non-Ozone Depleting Safe for Total Flooding of Occupied Spaces Clean - No Residue to Clean Up Non-Damaging to Hazard Contents FastActing EXTINGUISHING AGENT FM-2000 Agent (1,1,1,2,3,3,3-heptafluoropropane) is a compound of carbon, fluorine and hydrogen (CF3CHFCF3). It is colorless, odorless and electrically non-conductive. It suppresses fire by a combination of chemical and physical mechanisms without affecting the available oxy- gen. This allows personnel to see and breathe, permitting them to leave the fire area safely. FM-200 Agent has acceptable toxicity for use in occupied spaces when used as specified in the United States Environ- mental Protection Agency (EPA) Significant New Alternative Policy (SNAP) program rules. Although FM-2000 Agent is considered non- toxic to humans in concentrations necessary to extinguish most fires, certain safety considerations should be observed when applying and handling the agent. The discharge of FM-2000 Agent may create a haz- ard to personnel from the undecomposed agent itself and from the decomposition products which result when the agent is exposed to fire and other hot surfaces. Exposure to the agent is generally of less con- cern than is exposure to the decomposition products. Unnecessary exposure to the agent or the decomposition products should be avoided. TOXICITY In tests, the acute toxicity of FM-2000 Agent was shown to be equiva- lent to that of Halon 1301. FM-2000 Agent has been evaluated for car- diac sensitization through test protocols approved by the US EPA. The EPA's SNAP Program classifies FM-2008 Agent as acceptable for use as a total flooding agent in occupied spaces. Refer to the SNAP pro- gram rules for more information. CLEANLINESS FM-2008 Agent is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive "down-time" to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics ,rubber and electronic components are unaffected by exposure to FM-200 Agent. APPROVALS FM2000 Agent complies with the NFPA Standard 2001: Standard for Clean Agent Fire Extinguishing Systems, EPA SNAP Program (Signifi- cant New Alternate Policy), Underwriters Laboratories, Inc. (UL) and Factory Mutual Research Corporation (FMRC). USE FM-200® Agent is used in total flooding fire suppression systems. It is stored in steel containers, and is super-pressurized with nitrogen to aid in expelling the agent. The discharge time is 10 seconds or less. The maximum fill density of the agent storage is 70 Ib./ft.. (z Kidde Fire Systems Effective: June 2O14 K-90-1900 Rev BA Active Fire Suppression Agent UL Component Recognized FM Approved RoHS Complaint Table 1: F11111-200 Physical Properties Chemical Formula CF3CHFCF3 Molecular Weight 170.03 Freezing Point -204F (-131C) Boiling Point at 1 Alm 2.6F (-16.4C) Critical Temperature 215.1F (101.7C) Critical Density 36.76 Ib/ft3 (621 kg/m3) Critical Pressure 422 PSIA (29.0 bar absolute) Critical Volume 0.0258 cu ft/lb (1.61 Likf) Ozone Depletion Potential 0 Table 2: FM-200® Fire Protection Properties Cup Burner Concentration (n-Heptane) 6.70% v/v Use Concentration for n-I-leptane 8.00% v/v Use Concentration for Acetone 8.30% v/v Use Concentration for Isopropanol 9.00% v/v Use Concentration for Toluene 7.00% v/v Use Concentration for Class A (Surface Fires) * 6.25% v/v * Note: Automatic only per NFPA 2001 Table 3: FM-2000 Toxicity Properties NOAEL (No Observable Adverse Effect Level) 9.0% LOAEL (Lowest Observable Adverse Effect Level) 1 10.5% COMPATIBILITY Series For Use With Kidde ECS HFC-227ea x Kidde ECS Advanced Delivery FM-2000 X S This literature is provided for informational purposes only. KIDDE- FENWAL, INC. assumes no responsibility forthe product's suitability for a particular application. The product must be properly applied to work correctly.lf you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. FM-200 is a registered trademak of E.I. du Pont de Nemours and Company. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com S 52.75" 47.5" SAFET VALVE .EVEL INDICATOR TING LUGS YLINDER LINDER MEPLATE PLAN VIEW Kidde ECS Fire Suppression System Component Description S Aoo Kidde Fire Systems Cylinder and Valve Assembly, 200 lb. (90.7 kg) Effective: June 2014 Capacity 'K-9O-2O4O Rev BA FEATURES For use with UL Listed, ULC Listed and FM Approved Systems • RoHS Compliant See Kidde Manual 06-236225-001 for USCG Approval ORDERING INFORMATION Part Number Description 90-100200-101 STD 90-100201-101 w/LLI MATERIALS Valve Body: Brass Cylinder: Steel, Painted Red COMPATIBILITY Series For Use I I With Kidde ECS HFC-227ea X Notes: The safety cap must be installed on the valve outlet at all times, except when the cylinders are con- nected to the system piping, or being filled. The safety cap must not be removed from its chain. Cylinders manufactured prior to May 2014 have only 1 boss. The safety burst disk and other port are on the valve. See K-90-2070 for additional information. This literature is provided for informational purposes only. KIDDE- FENWAL, INC. assumes no responsibility for the products suitability for a particular application. The product must be property applied to work S correctly.lf you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddeflresystems.com Component Description Kdde Fire Systems Effective: January 2018 Electric Control Head Kit with Control Head Monitor Data Sheet K-85-3001 Rev AB FEATURES UL Listed, ULC Listed, and FM Approved for use with systems listed below in the Table, "COMPATIBILITY", on page 2. PIN: 85-890181-000 ORDER INFORMATION Part Number Description 85-890181-000 Kit, Includes: Electrical Control Head, 24 VDC, P/N WK-890181-000 Control Head Monitor, P/N 85-100000-100 (for more information, see data sheet K-85-3000) CONNECTION FOR FLEXIBLE ELECTRIC CONDUIT- 3/4" NPT FEMALE .- LOCKING PIN SEAL WIRE ELECTRIC I C3NTROLHEAO - LOCAL MANUAL RELEASE LEVER 6.18" ' (O} (157mm) PTN SWIVEL NUT INOICATOR AND 1.50(38mm) HEX THREAD1-1/4"-18 NF-3 READ RESET STEM SET RELEMED JE 4.00 (102mm) Figure 1. Electric Control Head MATERIAL Body: Brass SPECIFICATIONS Voltage: 24 VDC Current: 2.OA C S S. S S Figure 2. Electric Control Head and Control Head Monitor COMPATIBILITY Series DIOM PIN Supplement PIN Kidde ECS 500 psi with FK-5-1-12 Agent 06-237585-001 N/A Kidde ECS with 3 M NovecTm 1230 Fire Protection Fluid 06-236553-001 N/A Kidde ADS with 3MTm NovecTM 1230 Fire Protection Fluid 06-237256-001 N/A Kidde ECS with HFC-227ea Agent 06-236115-001 06-236115-003 Kidde Modular ECS with HFC-227ea Agent 06-236116-001 06-236116-002 Kidde ADS with HFC-227ea Agent 06-236068-001 06-236068-003 Kidde FE-13 Engineered Suppression System 06-236169-002 06-236169-003 Kidde FE-13Tm Modular Engineered Suppression System 06-236193-001 06-236193-002 Kidde 3MNovec 1230 (for UTC India Specifications) 06-237127-600 06-237127-601 Kidde ECS with FM-2001M (for UTC India Specifications) 06-237298-001 06-237298-002 Note: Agency listings also apply to the Fenwal Engineered Fire Suppression Systems, when the Control Head Monitor is used on these legacy product lines. EXPORT INFORMATION (USA) Jurisdiction: EAR Classification: EAR99 This document contains technical data subject to the EAR. All trademarks are the property of their respective owners. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The fire suppression system design, installation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly. If you need more information on this product, or if you have a particular problem or question, contact: KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000. e - 2 Kidde Fire System PdUU Fire Systems K-85-3001 Rev AB 02018 Kidde-Fenwal, Inc. 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddeflresystems.com Component Description Kffdde Fire Systems Effective: January 2018 Cylinder Mounting Straps Data Sheet K-85-O5O2 Rev M FEATURES UL Listed, ULC Listed, and FM Approved for use with systems listed in the Table, 'COMPATIBILITY," on page 2. Steel straps and brackets are used to mount the cylinders in a vertical position. Cylinder straps (PIN WK-283945-000, WK-283934-000, 06-235317-001, WK-281866-000, WK-294651-000, 06-236125-001 and 30710193) are available for all size cylinders. B F (hole size) C. I 1$I D Part Number Cylinder Size Cylinder O.D. Dimension A Dimension B Dimension C Dimension D Dimension E Dimension F WK-283945-000 10 lb., 7.07 in. 6.48 in. 9.62 in. 8.62 in. 1 in. 2.78 in. 0.437 in. 20 lb. (180 mm) (165 mm) (224 mm) (219 mm) (25 mm) (71 mm) (11 mm) WK-283934-000 40 lb., 9 in. 8.16 in. 11.69 in. 10.69 in. 1 in. 3.50 in. 0.437 in. 70 lb. (229 mm) (207 mm) (297 mm) (272 mm) (25 mm) (89 mm) (11 mm) 06-235317-001 125 lb., 12.75 in. 12.93 in. 16.18 in. 14.56 in. 1.75 in. 5.59 in. 0.625 in. 200 lb. (324 mm) (329 mm) (411 mm) (370 mm) (44 mm) (142 mm) (16 mm) WK-281866-000 350 lb. 16 in. 15.50 in. 19.50 in. 17.88 in. 1.75 in. 6.06 in. 0.625 in. (406 mm) (394 mm) (495 mm) (454 mm) (44 mm) (154 mm) (16 mm) WK-294651-000 600 lb. 22 in. 21.56 in. 25.75 in. 24.12 in. 1.75 in. 10.25 in. 0.625 in. (559 mm) (548 mm) (654 mm) (613 mm) (44 mm) (260 mm) (16 mm) 06-236125-001 900 lb. 24 in. 23.75 in. 27.75 in. 26 in. 1.75 in. 12.13 in. 0.625 in. (610 mm) (603 mm) (705 mm) (660 mm) (44 mm) (308 mm) (16 mm) 30710193 11001b 30 in 30-1/8 in (765 34-1/4 in (870 32-1/4 in (819 1-1/2 in (38 15 in 7/16 in (11 (762 mm) mm) mm) mm) mm) (381 mm) mm) C 0 S S MATERIALS Steel, Painted Black SAE 1020 COMPATIBILITY Series DIOM P/N Kidde ECS 500 psi with FK-5-1-12 Agent 06-237585-001 Kidde ECS with 3Mrm Novec 1230 Fire Protection Fluid 06-236553-001 Kidde Marine with 3Mrm Novecrm 1230 Fire Protection Fluid 06-236559-001 Kidde ECS with HFC-227ea Agent 06-236115-001 Kidde Modular ECS with HFC-227ea Agent 06-236116-001 Kidde ECS Marine with HFC-227ea Agent 06-236225-001 Kidde ADS Marine with FM-2001m Agent 06-236595-001 Kidde ADS with FM-200 Agent 06-236068-001 Cylinder Size Agent Series 10, 20 lb 40, 70 lb 125 lb 200/ 350/ 600/ 900/ 1100 lb 225* lb 395* lb 675* lb 1010* lb FK-5-1-12 ECS 500 x x x x x x x x psi NovecTm ECS X X X X X X X 1230 ADS X X X X ECS X X X X X X X HFC-227ea ECS X X X X X X Modular ADS X I X I X X * 225, 395, 675, and 1010 lb cylinders are only applicable to Kidde ADS with HFC-227ea systems. EXPORT INFORMATION (USA) Jurisdiction: EAR Classification: EAR99 This document contains technical data subject to the EAR. All trademarks are the property of their respective owners. iThis literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The fire suppression system design, installation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly. If you need more information on this product, or if you have a particular problem or question, contact: KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000. _I 2 Kidde Fire System! ! 'duu Fire Systems K-85-0502 Rev AA 02018 Kidde-Fenwal, Inc. 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 ww.ldddefiresystems.com WIRING SCREW TERMINALS FRONT VIEW COVER REMOVED SWITCH COVE PIPING SIDE SECTION Component Description Kdde Fire Systems Pressure Operated Switch Data Sheet Effective: January 2018 K-85-0524 Rev M FEATURES UL Listed, ULC Listed, and FM Approved for use with the systems listed in the Table, "COMPATIBILITY," on page 2. P/N: 81-486536-000 15 AMP 125 VAC 10 AMP 250 VAC 314 HP 1-2-3 PH 125-480 VAC 112" SUPPLY PIPE WITH UNION FRONT VIEW OPERATED -- SET I NC NC NC 3 EACH SIDE ONDUIT KOUTS 0C C• C• -, 0 0 0 NO NO NO MALE, TO SYSTEM PRESSURE INLET WIRING DIAGRAM / STEM SHOWN IN SET POSITION- PULL UP ON STEM TO MANUALLY ERATED A OPERATE SWITCH I- Q•375" OPERATED SWITCH I 3P.Dt I I .- 8 COVER SCREWS TO RESET PUSH STEM TO SET POSITION S Notes: The switch may be mounted in any posi tion, however, the preferred installation is upright, as shown. Any load connection to the switch must not exceed the switch rating, and shall utilize a suitable protection device (i.e., circuit breaker, fuse) Contact Ratings (3 PDT) - 15 Amp @125Vac - 10Amp©250Vac - 3/4 HP@250Vac - 1,2,or3Phase COMPATIBILITY Series DIOM P/N Kidde ECS 500 psi with FK-5-1-12 Agent 06-237585-001 Kidde ECS with 3MTm Novec 1230 Fire Protection Fluid 06-236553-001 Kidde ADS with 3M Novecrm 1230 Fire Protection Fluid, 06-237256-001 Kidde Marine with 3MTm Novecrm 1230 Fire Protection Fluid 06-236559-001 Kidde ADS Marine with 3Mrm Novec 1230 Fire Protection Fluid 06-237257-001 Kidde ECS with HFC-227ea Agent 06-236115-001 Kidde Modular ECS with HFC-227ea Agent 06-236116-001 Kidde ECS Marine with HFC-227ea Agent 06-236225-001 Kidde ADS Marine with HFC-227ea Agent 06-236595-001 Kidde ADS with HFC-227ea Agent 06-236068-001 Kidde High Pressure CO2 81-CO2MAN-001 Kidde Fire Systems Marine Carbon Dioxide Version 2.4 DIOM 220610 Kidde 3MNovec 1230 (for UTC India Specifications) 06-237127-600 Kidde ECS with FM-200 (for UTC India Specifications) 06-237298-001 EXPORT INFORMATION (USA) Jurisdiction: EAR Classification: EAR99 This document contains technical data subject to the EAR. All trademarks are the property of their respective owners. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The fire suppression system design, installation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly. If you need more information on this product, or if you have a particular problem or question, contact: KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000. .. ..i - 2 Kidde Fire Systems - ' ruuue Fire Systems K-85-0524 Rev AA 02018 Kidde-Fenwal. Inc. 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 ww.kiddefiresysIems.com S Kidde ECS Fire Suppression System I Component Description / 7 Kidde Fire Systems Supervisory Pressure Switch, Effective: June 2014 0 1-1/2",2", and 3" Valve, PIN: 06-118262-001 K-90-9047 Rev BA FEATURES Both Normally Open and Normally Closed Configuration • UL Listed and FM Approved with One Unit • CRUUS Recognized Component (US and Canada) Suitable for 10 lb. Through 900 lb. Kidde ECS Systems DESCRIPTION The Kidde ECS System cylinder supervisory pressure switch is intended to detect a fall in pressure in the agent cylinder. The cylinder supervisory pressure switch can be wired for either normally open or normally closed opera- tion, depending on installation requirements. This cylin- der supervisory pressure switch can be installed on Kidde Engineered System cylinders, 10 lb. through 900 lb. size. For 3" valves manufactured prior to May 1, 2013 use Supervisory Pressure Switch PIN: 06-118263-001. OPERATION When the pressure in the agent container drops from the standard charge pressure of 360 psi (25 bar) to below 288 psi (19.86 bar) the switch operates. If wired in the NC (open-under-pressure) configuration the resulting pres- sure drop will cause the contacts to close. When con- nected to a monitored circuit of a suppression control panel the switching will result in an alarm or trouble con- dition. Note: If the temperature of the cylinder contents drop close to a temperature of 32°F (0°C) or less the pressure in the cylinder will be equal to or less than 288 psi (19.86 bar) and the switch will oper- ate. However the minimum operating tempera- ture of the system is 32°F (0°C). INSTALLATION The supervisory pressure switch can be installed on a fully charged cylinder, without loss of pressure, provided the unit is handled with care and only by trained service personnel. Remove the protective cap from the pressure connection. Do not apply thread compound to the threads. Install the switch with an 1-1/16" open-ended wrench while holding the pressure connection with a 7/ 16" open-end wrench. Tighten hand-tight, plus one-quar- ter turn. Leak check using a leak detector or bubbling solution. Secure switch body with wrench when connect- ing electrical conduit. Isolate the assembly from shock, vibration and areas subject to wide-ranging or rapid tem- perature fluctuations. Disconnect all supply circuits before wiring the supervisory switch. This literature is provided for informational purposes only. KIDDE- FENWAL, INC. assumes no responsibility for the products suilability for a particular application. The product must be properly applied to work correctly.lf you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL Inc. 02014 Kidde-Fenwal. Inc. ORDERING INFORMATION The cylinder supervisory pressure switch offers com- bined normally opened and normally closed functionally. The part number for ordering the cylinder supervisory pressure switch is 06-118262-001. SPECIFICATIONS Setting: 288 psi (19.86 bar) on falling pressure Electrical rating: 5 Amps, 250 Vac Wire color coding: Blue = Normally Open Black = Normally Closed Violet = Common Operating temperature range: 32 to 130°F (0 to 54°C) Pressure connection: 0.25" SAE 45° flare female with valve core deflector Wetted materials: EPR, Brass Copper Lead length: 36 in. +1- 2 in. (914 mm +1-50 mm) COMPATIBILITY Series For Use With Kidde ECS HFC-227ea X Kidde ECS Advanced Delivery FM-2004D X FM-200 is a registered trademark of E.I. du Pont de Nemours and Company. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com S Component Description Valve Outlet Adapters Data Sheet idde Fire Systems Effective: January 2018 K-45-0518 Rev AA FEATURES UL Listed, ULC Listed, and FM Approved for use with the systems listed in the Table, "COMPATIBILITY," on page 2 P/N: WK-28390X-000 B (VALVE OUTLET CONNECTION) 9 -1 A (SYSTEM PIPE CONNECTION) Note: For direct connection of cylinder valve to distribution piping. Part Number Size A B C D WK-283904-000 1-1/2 in. 1-1/2 in. (38 mm) 1-7/8 in. 2-11/16 in. 2-1/2 in. (38 mm) 11-1/2 NPT 12 UNJ (68 mm) (64 mm) Hex WK-238905-000 2 in. 2 in. (51 mm) 2-1/2 in. (64 mm) 3-1/8 in. 3 in. (51 mm) . 11-1/2 NPT 12 UNJ (79 mm) (76 mm) Hex MATERIALS Brass 40 COMPATIBILITY Series DIOM PIN Kidde ECS 500 psi with FK-5-1-12 Agent 06-237585-001 Kidde ECS with 3Mrm Novec 1230 Fire Protection Fluid 06-236553-001 Kidde ADS with 3M Novec 1230 Fire Protection Fluid 06-237256-001 Kidde Marine with 3MIm Novecrm 1230 Fire Protection Fluid 06-236559-001 Kidde ADS Marine with 3M NOVeCTM 1230 Fire Protection Fluid 06-237257-001 Kidde ECS with HFC-227ea Agent 06-236115-001 Kidde Modular ECS with HFC-227ea Agent 06-236116-001 Kidde ECS Marine with HFC-227ea Agent 06-236225-001 Kidde ADS Marine with HFC-227ea Agent 06-236595-001 Kidde ADS with HFC-227ea Agent 06-236068-001 Kidde FE-131M Engineered Suppression System 06-236169-002 Kidde FE-13Tm Modular Engineered Suppression System 06-236193-001 Kidde 3MTMNovec 1230 (for UTC India Specifications) 06-237127-600 Kidde ECS with FM-200 (for UTC India Specifications) 06-237298-001 S EXPORT INFORMATION (USA) Jurisdiction: EAR Classification: EAR99 This document contains technical data subject to the EAR. All trademarks are the property of their respective owners. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no :esponsibility for the product's suitability for a particular application. The fire suppression system design, installation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly. If you need more information on this product, or if you have a particular problem or question, contact: KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000. li! .J A - 2 Kidde Fire Systerm 1xiluuIc 400 Main Street K-45-0518 Rev Ph: 508.881.2000 Fire Systems Ashland, MA 01721 02018 Kidde-Fenwal, Inc. . Fax: 508.881.8920 www,k)ddeflresystemscom S S Component Description 7Kidde Fire Systems Warning Nameplate Effective: March 2017 Designed for use with Clean Agent Systems K-85-9000 Rev AA FEATURES Approved for use with Clean Agent Systems P/N: WK-218270-000 The Warning Nameplate is mounted inside the protected hazard. It applies to extinguishing agents such as: FM-2000 (HFC-227ea) Agent 3MTM NovecTM 1230 Fire Protection Fluid Inert Gas Agents - 9.00 _-._ _ _ _ _ _ WHEN ALARM SOUNDS VACATE AT ONCE 5.00 FIRE EXTINGUISHING AGENT BEING RELEASED 0.34 Typ - 0.34 .28 ThRU 1-vp 4 HOLES Material: Aluminum Type 1100-H13, 0.032 thick Note: All characters to be 75 pt. Alternate Gothic #2, all letters to be recessed 0.003 to 0.005 and painted with red chip proof enamel Color: No. 21105 per Fed. Std. 595 Approximate Weight: 3 oz. Finish: One coat clear lacquer both sides All trademarks are the property of their respective owners. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721 USA. Telephone: (508) 881-2000. 02017 Kidde-Fenwal, Inc. This document does not contain any export controlled technical data. Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Ph: 508.881.2000 Fax: 508.881.8920 www.kiddeflresystems.com Kidde ECS Fire Suppression System Component Description ( Z Kidde Fire Systems Effective: June 2014 Warning Nameplate (FM-200CR') K-90-9030 Rev BA FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems • RoHS Compliant See Kidde® Manual 06-236225-001 for USCG Approval PIN: 06-231865-739 10.000 0.063 0.340 - 9.360 -i [0.340 WARNING THIS AREA IS PROTECTED BY A. 0.062 FM-200® EXTINGUISHING 5.000 4.360 SYSTEM. DO NOT ENTER WITHOUT AUTHORIZATION DURING OR AFTER DISCHARGE ___ 0.281 .005 DIA. TYP. 4 HOLES MATERIALS Aluminum Type 1100-1-114,0.032 ± 0.003 Thick. All Let- ters to be 48 pt., Alternate Gothic #2, Etched 0.003 to 0.005 and Filled in With Red Chip Proof Enamel Color No. 21105 per Fed. Stc. 595 Finish: One Coat Clear Lacquer Both Sides COMPATIBILITY Series For Use With Kidde ECS HFC-227ea X Kidde ECS Advanced Delivery FM-200® X This literature is provided for informational purposes only. KIDDE- FENWAL, INC. assumes no responsibility for the products suitability for a particular application. The product must be property applied to work correctly.lf you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc 02014 Kidde-Fenwal, Inc. FM-200 is a registered trademark of E.I. du PDnt de Nemours and Company. Kidde is registered trademak of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Jfr Kidde Fire Systems Kidde Fire Systems - Flow Calculation Software v4.0.0 (HFC-227ea) UL: EX4674 / Component of FM Approved System COSCO FIRE PROTECTION 4990 GREENCRAIG LANE SAN DIEGO CA. 92123 Phone: (858) 444-2000 File Name: Proof Calc 1.FC4 Consolidated Report Customer Information Company Name: COSCO FIRE PROTECTION Address: 4990 GREENCRAIG LANE SAN DIEGO, CA. 92123 Phone: 858-444-2000 Contact: HUGO A. Title: DESIGNER Project Data Project Name: CARLSBAD SERVER ROOM Designer: HUGO A. Number: 10.CA_5398 Account: Location: Description: Enclosure Report Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: 1 Enclosure 1 SERVER ROOM Enclosure Temperature: Number of Nozzles: Calculation Date/Time: Thursday, April 26, 2018, 9:19:44 AM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Key ID: 92499735 2 Page: 1 of 8 fKidde Fire Systems Consolidated Report Minimum: 70 F Width: 19.9 ft Maximum: 70 F Length: 32.0 ft Max. Concentration: 7.03 °" Height: 9.2 ft Design Concentration: Volume: 5858.6 ft Adjusted: 7.03 % Non-permeable: 374.4 ft Minimum: 7.00% Total Volume: 5484.2ft 3 Mm. Agent Required: 187.1 lb Adjusted Agent Required: 188.0 lb Agent Source Report Agent: FM-200 / Propellant N2 (FM-200 is a Trademark of DuPont) Container Name: 200 lb Cylinder w/LLl Container Part Number: 90-100201-101 Agent Per Container: 188.0 lb Fill Density: 65.8 lbs / cubic ft Number of Main Containers: 1 Number of Reserve Containers: 0 Container Empty Weight: 141.0 lb Weight, All Containers + Agent: 329.0 lb Floor Area Per Container: 1.01 ft 2 Floor Loading Per Container: 326 lbs / ft 2 S S Calculation Date/Time: Thursday, April 26, 2018, 9:19:44 AM Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Key ID: 92499735 S Page: 2 of 8 0 Kidde Fire Systems Consolidated Report Parts Report Total Agent Required: 188.0 lb Container Name: 200 lb Cylinder w/LLI (Part: 90-100201-101) Number of Containers: 1 Nozzle Type Nozzle Area Part Number E1-N1 3600 0.8053 in 2 90-194026-358 El-N2 360° 0.8053 in 2 90-194026-358 Pipe & Fittings Type Diameter Length Elbows (90) Elbows (45) Tees Unions 40T 1-1/4 in 34.00 ft 6 0 1 0 40T 21n 0.50 ft 0 0 0 0 Other Objects Name Quantity Part Number 2 in. Valve Outlet Adapter 1 283905 System Acceptance Report System Discharge Time: 9.2 seconds Percent Agent In Pipe: 21.2% Percent Agent Before First Tee: 10.5% Dead Volume: 0.0% (0.0 lb) Enclosure Number: 1 Enclosure Name: SERVER ROOM Minimum Design Concentration: 7.00% Adjusted Design Concentration: 7.03% Predicted Concentration: 7.03% Maximum Expected Agent Concentration: 7.03% (At 70 F) Calculation Date/Time: Thursday, April 26, 2018, 9:19:44 AM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Key ID: 92499735 Page: 3 of 8 .00 Kidde Fire Systems Consolidated Report Minimum Adjusted Predicted Average Agent Agent Agent Nozzle Nozzle Required Required Delivered Pressure El-Ni 93.6 lb 94.0 lb 94.1 lb 104.8 psig El-N2 93.6 lb 94.0 lb 93.9 lb 104.4 psig S Calculation Date/Time: Thursday, April 26, 2018: 9:19:44 AM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Key ID: 92499735 Page: 4 of 8 . . . Kidde Fire Systems Consolidated Report Pipe Network Report Total Total Pipe Start End Pipe Pipe Pipe Elevation Equivalent Nozzle Nozzle Nozzle Nozzle Description Section Node Node Type Diameter Length Union Change Length Name Size Type Area Container-On Man./End 0 2 2in3.63ft 0 3.63 ft 50.00 ft Adapter System 2 3 2ifl 0.26 ft 0 9.00 ft Pipe System 3 4 401 2 i 0.50 ft 0 ------ 0.50ft Pipe System 4 5 401 171/4 in U SO tt 0 ------ --- 0.50 ft Elbow (90) System 5 6 401 1-1/4 in 0 3.70 ft Pipe System 6 7 40T 1 1/4 in 6 38 ft 0 6.38A 6 40 ft Elbow (90) System 7 8 40T 1-1/4 in 0 T 3.70 ft Pipe System 8 9 40T 1 1/4 in 4 88 ft 0 4.90 ft Tee System 9 10 40T 1-1/4 in ------0 ------7.50 ft Pipe System 10 11 40T 1-1/1 in 8.42 ft 0 8.40 ft Elbow (90) System 11 12 - 40T 1-1/4 in ------ - TTT 3:70 ft Pipe System 12 13 40T 1-1/4 in 2.00 ft 0 ---- 2.00 ft Elbow (90) System 13 14 40T 1-1/4 in P 3.70 ft P;pe&N077lP System 14 15 401 1-1/4 in 1.13 ft 0 -1.13 ft 1.10 ft E N2 1-1/4 in 360 0.8053 in 2 Tee System 9 16 401 1-1/4 in ------0 ------7.50 ft Pipe System 16 17 401 1-1/4 in 7.58 ft 0 ------ 7.60 ft Elbow (90) System 17 18 40T 1-1/4 in 0 3.70 ft Pipe System 18 19 401 1-1/4 in 2.00 ft 0 ----- 2M ft Elbow (90) System 19 20 40T 1-1/4 in 0 3.70 ft Pipe&Nozzle System 20 21 40T 1-1/4 in 1.13 ft 0 -1 13 ft 1 I0 ft E1N1 1-1/4 in 360° 0 8053 in Key ID: 92499735 Page: 5 of 8 kidde Fire Systems Consolidated Report View #: I - Isometric View-Node -N2 W 200 lb Cylindi w/LLI 0 Key ID9735 Pa•of 8 LU _8.416t't 11.125fl E1-N2 . kidde Fire Systems Consolidated Report View #: 2 - Isometric View-Pipe Lengths Key ID: 92499735 Page: 7 of 8 :!kidde Fire Systems Consolidated Report View #: 3 - Isometric View-Pipe Diameters in 1-1/4 in 11-1/4 in E1-N2 W 200 lb Cylindr wiLLI 0 Key ID: •735 Paof 8 fTC2-0 (9 - O L 4~~- DF-60238:Cl • A2-350 MRP.2002(E) Aaent Release Control Panel General The MRP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, indus- trial and institutional buildings requiring agent-based releasing. The MRP-2002 is compatible with System Sensor's i3 detec- tors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory freeze' signal when the ambi- ent temperature falls below the detector rating of approxi- mately 45°F (7.220C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterfiow devices, tamper switches and other normally-open contact devices. Refer to the Fire'Lite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appli- ance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2002 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm infor- mation on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MRP-2002E offers the same features as the MRP-2002 but allows connection to 220/240 VAC. Unless otherwise spec- ified, the information in this data sheet applies to both the 110/ 120 VAC and 220/240 VAC versions of the panels. Features Listed to UL Standard 864, 9th edition. FM Approved. Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001. Meets International Building Code (IBC) seismic require- ments. Disable/Enable control per input zone and output zone. Extensive transient protection. Dual hazard operation. Adjustable pre-discharge, discharge and waterfiow delay timers. Cross-zone (double-interlock) capability. Six programmable Style B (Class B) lDCs (Initiating Device Circuit). System Sensor i3 series detector compatible. Four programmable Style Y (Class B) output circuits - (spe- cial application power). Strobe synchronization: - System Sensor - Wheelock (a FlreuTeALarms by Honeywell - Gentex - Faraday - Amseco Three programmable Form-C relays. 7.0 amps total 24 VDC output current. Resettable and non-resettable output power. Built-in Programmer. ANN-BUS connector for communication with optiona devices (up to 8 total of any of the following): - ANN-80 Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module 80-character LCD display (backlit). Real-time clock/calendar with daylight savings time control. History log with 256 event storage. Piezo sounder for alarm, trouble and supervisory. 24 volt operation. Low AC voltage sense. Outputs Programmable for: - Releasing Circuits or NACS NACs programmable for: - Silence Inhibit - Auto-Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady Signal - Silenceable or Non-silenceable - Release Stage Sounder Automatic battery charger with charger supervision. DF-60238:CI • 6/14/2011 - Page 1 of 4 Optional Dress Panel DP-51050 (red). Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet. Optional CAC-5X Class A Converter Module for Outputs and lDCs. Optional 4XTMF Municipal Box Transmitter Module. Optional Digital Alarm Communicators (411 411 LID, 411UDAC). Optional ANN-SEC card for a secondary ANN-BUS. PROGRAMMING AND SOFTWARE: Custom English labels (per point) may be manually entered or selected from an internal library file. Programmable Abort operation. Three programmable Form-C relay outputs. Pre-programmed and custom application templates. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. USER INTERFACE: Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. ANN-Bus for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red). SUPERVISORY (yellow). TROUBLE (yellow). AC POWER (green). ALARM SILENCED (yellow). DISCHARGED (red). PRE-DISCHARGE (red indicator). ABORT (yellow indicator). CONTROL BUTTONS ACKNOWLEDGE. ALARM SILENCE. SYSTEM RESET (lamp test). DRILL. AC Power —TB1 MRP-2002: 120 VAC, 60 Hz, 3.66 amps. MRP-2002E: 240 VAC, 50 Hz, 2.085 amps. Wire size: minimum #14 AWG (2.0 mm2) with 600V insula- tion. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp. Supervised, nonpower-limited. Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55). Minimum Battery Size: 7 Amp Hour. Initiating Device Circuits - TB4 and TB6 Alarm Zones 1 - 5 on T134. Alarm Zone 6 on T136. Supervised and power-limited circuitry. Style B (Class B) wiring with Style D (Class A) option. Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 Ohms. End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Standby Current: 4 mA. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Notification Appliance and Releasing Circuit(s) - TBS and TB7 Four Output Circuits. Style Y (Class B) or Style Z (Class A) with optional con- verter module. Special Application power. Supervised and power-limited circuitry. Normal Operating Voltage: Nominal 24 VDC. Maximum Signaling Current: 7.0 amps (3.0 amps maximum per NAC). End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 1252). Max. Wiring Voltage Drop: 2 VDC. Refer to the Fire.Lite Device Compatibility Document for com- patible listed devices. Form-C Relays - Programmable - TB8 Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Relay Contact Ratings: —2 amps @ 30 VDC (resistive) —0.5 amps @ 30 VAC (resistive) Auxiliary Trouble Input - J6 The Auxiliary Trouble Input is an open collector circuit which can be used to monitor external devices for trouble conditions. It can be connected to the trouble bus of a peripheral, such as a power supply, which is compatible with open collector cir- cuits. Special Application Resettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors (see note). Power-limited Circuitry. Refer to the Fire'Lite Device Compatibility Docum-?nt for com- patible listed devices. NOTE: Total current for resettable power, nonresettabie power and Output Circuits must not exceed 7.0 amps. Special Application Resettable or Nonresettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA (see noe 1). Power-limited Circuitry. Jumper selectable by JP31 for resettable or nonresettable power. Refer to the Fire'Lite Device Compatibility Document for com- patible listed devices. Page 2 of 4— DF-60238:C1 • 6/14/2011 Product Line Information MRP-2002: Six-zone, 24 volt Agent Release Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard agent releasing applications. MRP-2002E: Same as above but allows connection to 220/ 240 VAC. CAC-5X: Class A Converter Module can be used to convert the Style B (Class B) Initiating Device Circuits to Style D (Class A) and Style Y (Class B) Output Circuits to Style Z (Class A). NOTE: Two Class A Converter modules are required to convert all four Output Circuits and six Initiating Device Circuits. 4XTMF: Transmitter Module provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white: see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY (16911): Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DF-52431). ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429). ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430). ANN-SEC: Optional card for a secondary ANN-BUS. See 53944. DP-51050: Dress panel (red) is available as an option. The dress panel restricts access to the system wiring while allow- ing access to the membrane switch panel. TA-CE: Trim-ring (red) is available as an option. The trim-ring allows semi-flushing mounting of the cabinet. BB-26: Battery box, holds up to two 26 Amp Hour batteries and CHG-75. BB-55: Battery box, houses two 55 Amp Hour batteries. SEISKIT-COMMENC: Seismic mounting kit; required for seis- mic-certified installations. BAT Series Batteries: Refer to DF-52397. PRN-6F: UL-listed compatible event printer. Dot-matrix, trac- tor-fed paper, 120 VAC. PAT-PK-CABLE: Programming cable. Used to update the FACP's flash firmware. (Also requires an R5485 to RS232 converter). DF-60238:C1 • 6/14/2011 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators .....................................................................8 Electrical Specifications MRP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps MRP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR- CE): 22.00° (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - Height 20.00" (50.80cm) - Width 22.50" (57.15cm) - Depth 8.50" (21.59cm) Temperature and Humidity Ranges ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C160 - 80°F NFPA Standards The MRP-2002(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - NFPA 12 CO2 Extinguishing Systems (High Pressure Only) - NFPA 12A Halon 1301 Extinguishing Systems - NFPA 12B Halon 1211 Extinguishing Systems - NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module) - NFPA 2001 Clean Agent Fire Extinguishing Systems Agency Listings and Approvals The listings and approvals below apply to the basic MRP- 2002(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:0216 MEA: 333-07-E This system meets NFPA requirements for operation at 0 - • Seismic Listing: Reference certificiate of compliance 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH VMA - 45894-01 by the VMC Group (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the NOTE: For ULC-listed model, see DF-60443. useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use This document is not intended to be used for installation purposes. -- I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I BlClNLIN & MNIMCiiUNG At specifications are subject to change without notice. I QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-60238:C1 • 6/14/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:0183 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: KIDDE-FENWAL, 1NC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terriII.garIandkidde-fenwal.com DESIGN: Model ARIES fire alarm control unit. Automatic, manual, local, central station, waterflow, sprinkler supervisory and releasing device services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: 76-600000-001 ARIES Control Unit 76-600000-004 Motherboard 76-600000-011 Keypad/Display 06-118394-002 Power Supply 06-220023-001 In-Line Releasing Device (EOLD) 76-600000-002 Enclosure *76-600000-009 Network Interface Card RATING: Primary: 120/240 VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm sinàD, the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 06-02-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52353:a • F-250 BG-1 2LR and BG-1 2LRA fluI.Ar!tiin Arwnt ct*itinc 8 Fire Lire0ALarmS by Honeywell Cnr I The BG-12LR and BG-12LRA are Agent Release Stations designed for use with Fire-lite Fire Alarm Control Panels with releasing capabilities and RP Series Releasing Systems. Features Non-coded, dual-action operation. Made with durable polycarbonate. Optional surface backbox. BG-12LRA INCLUDES: Abort switch. Power-on indication. Released indication. Manual release (dual-action). BG-12LR INCLUDES: Dual-action release only. Applications The BG-12LRA and BG-12LR are ideal for areas such as clean rooms and computer rooms where a chemical agent is used to extinguish a fire. Product Line Information BG-12LRA: Agent release station with abort switch, Release LED, Normal LED. BG-12LR: Dual-action agent release station. SBA-10: Surface backbox for BG-12LRA, metal. Dimensions 4.5(11.43cm) W x 8.188" (20.8 cm) Lx 1.375" (3.49 cm) D. SB-10: Surface backbox for BG-12LR, metal. Dimensions 4.125" (10.48 cm) W x 5.5" (13.97 cm) Lx 1.375" (3.49 cm) D. SB-I/O: Surface backbox for BG-12LR, plastic. BG12TR: Optional trim ring for semi-flush mounting. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in progress. Consult fac- tory for latest listing status. UL/ULC Listed: S711 MEA Listed: 67-20-E FM Approved CSFM: 7150-0075:184 Dual Action BG-12LR SYSTEM SYSTEM NORMAL ACTIVATED o 0 TO ABORT - HOLD IN Dual Action BG-12LRA (shown activated) DF-52353:a • 08/4/10 - Page 1 of 2 Wiring ------------ 24 VDC ------------ Release Relay A B System Operated LED (Red) 10K 1/4W System Normal LED (Green) 10K 1/4W N.O. Abort Switch 00 To 4 Abort 10K,1/4W Circuit E Resistors (+) 2 To Manual Release Circuit 4 10K,1/4W Resistors Mount End-of-Line Resistor on the last unit. Mount 4.7K ELR on the last unit when abort switch and manual release switch are connected to control panel circuits. Mount 47K resis- tor on last unit when abort switch and manual release switch are connected to monitor module or control module. Refer to control panel manual for the listed ELR. Refer to the product installation documentation for connection to the control panel Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corp. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use 1313-1 2LRA (Rear view) Agent Release Pull Station of this document is strictly prohibited. - This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. 0TTIMVETT11".We cannot cover all specific applications or anticipate all requirements. ElffillEENIG & MNIMC1fllNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52353:a • 08/4/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1076:0147 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garlandkidde-fenwal.com DESIGN: Models B1 and B1 1, 30195000002*, 30195000004*, 30-330001-001, 30-330001-002, 84-330001-001 and 84-330001-002 key lock, push bar, noncoded manual pull stations; Models 30195000001* and 30195000003* key lock, no push bar, noncoded manual pull stations. Suitable for outdoor use when installed with Model SGB-32C back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * Only Models 30-195000-001, -002, -003, and -004 manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *update 06-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52521:131 • F-505 P Series Photoelectric Smoke Detectors 8 Fire uTe'Atarms by Honeywell - • . General System Sensor's i3TM Series photoelectric and photoelectric/ thermal smoke detectors represent a significant advancement in conventional detection, incorporating three key features: installation ease, intelligence, and instant inspection. Installation ease. The i Series redefines installation ease with its plug-in design. This allows an installer to pie-wire the bases included with the heads. The large wire-entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of backbox mounting methods, as well as direct mounting with drywall anchors. To complete the installation, P Series heads plug into the base with a simple Stop-Drop 'N LockTm action. Intelligence. P Series detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensa- tion and smoothing algorithms, to minimize nuisance alarms, are standard in the P Series. When connected to the 2W-MOD loop test/maintenance module, two-wire P detectors are capa- ble of generating a remote maintenance signal when they need cleaning. This signal is indicated by LEDs located at the module and at the panel. To read the sensitivity of P detectors, the SENS-RDR is a wireless device that displays sensitivity in terms of percent-per-foot obscuration. Instant inspection. The P Series provides wide-angle red and green LED indicators for instant inspection of detector condi- tion. The LEDs indicate: normal standby, out-of-sensitivity, alarm, or freeze trouble conditions. The "EZ Walk" loop test feature is available on two-wire P Series detectors when con- nected to the 2W-MOD loop test/maintenance module. The "EL Walk" feature verifies the initiating loop wiring by providing LED status indication at each detector. Features Plug-in detector line - mounting base included. Large wire-entry port. In-line terminals with SEMS screws. Mounts to octagonal and single-gang backboxes, 4° (101.6 mm) square backboxes, or directly to ceiling. Stop-Drop 'N Lock attachment to base. Removable detector cover and chamber for easy cleaning. Built-in remote maintenance signaling. Drift compensation and smoothing algorithms. Simplified sensitivity measurement. Wide-angle, dual-color LED indication. Loop testing via "EZ Walk" feature. Built-in test switch. Specifications PHYSICAL SPECIFICATIONS Operating Temperature Range: For models 2W-B and 4W-B: 32°F to 120°F (0°C to 490C); for thermal models 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.80C). Operating Humidity Range: 0% - 95% RH, non-condensing. Thermal Sensor: 135°F (57.2°C) fixed (models 2WT-B, 4WT-B). Freeze Trouble: 41°F (5°C) (models 2WT-B and 4WT-B). Sensitivity: 2.5%/foot (0.762%/meter) nominal. Input Terminals: Utilize 14 to 22 AWG wire. Dimensions (including base): 5.3° (134.62 mm) diameter, 2.0° inches (50.8 mm) high. Weight: 6.3 oz. (178.6 grams). Mounting Options: 3.5 (88.9 mm) octagonal backbox; 4' (101.6 mm) octagonal backbox; single-gang backbox; 4 (101.6 mm) square backbox with a plaster ring; or direct mount to ceiling. ELECTRICAL SPECIFICATIONS Operating Voltage: 12/24 V non-polarized nominal; 8.5 V minimum; 35 V maximum. Maximum Alarm Current" For two-wire models: 130 mA lim- ited by control panel; For four-wire models: 20 mA © 12 V, 23 mA © 24 V. Alarm Contact Ratings: For four-wire models: 0.5 A © 30 VACNDC; not applicable for two-wire models. LED Modes Green LED Red LED Power Up Blink every 10 sec- onds Blink every 10 sec- onds Normal (Standby) Blink every 5 sec- or,ds OFF Out of Sensitivity OFF Blink every 5 sec- onds Freeze Trouble OFF Blink every 10 sec- onds Alarm OFF Solid ON Power Up Sequence for LED Indication Condition Duration Initial LED Status Indication 80 Seconds DF-52521 :B1 • 4/13/2012 - Page 1 of 2 Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number _, Listed to Underwriters Laboratories UL 268 Fire Protection Signaling Systems. The detector shall be a photoelectric type (models 2W-B, 4W-B) or a combination pho- toelectric/thermal (models 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.20C). The detector shall include a mounting base for mounting to 3.5° (88.9 mm) and 4" (101.6 mm) octag- onal, single-gang, and 4" (101.6 mm) square backboxes with a plaster ring, or directly mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5%/foot (0.7620/o/meter) as measured in the UL smoke box. The detector shall be capable of auto- matically adjusting its sensitivity by means of drift compensa- tion and smoothing algorithms. The detector shall provide dual-color LED indication which blinks to indicate power-up, normal standby, out-of-sensitivity, alarm, and freeze trouble (models 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD module, two-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capa- bility to verify the circuit without testing each detector individu- ally. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S911 FM Approved CSFM: 7272-1653:152 MEA: 290-01-E Maryland State Fire Marshal: Permit #2093 Product Line Information 2W-B: Two-wire photoelectric smoke detector. C2W-BA: Same as 2W-B, ULC listing. 2WT-B: Two-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C2WT-BA: Same as 2WT-B, ULC listing. 4W-B: Four-wire photoelectric smoke detector. NW-BA: Same as 4W-B, ULC listing. 4WT-B: Four-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C4WT-BA: Same as 4WT-B, ULC listing. ACCESSORIES: 2W-MOD2: Two-wire loop test/maintenance module. SENS-RDR: Sensitivity reader. A77-AB2: Retrofit adapter bracket, 6.6" (167.7cm) diameter. FireLite® Alarms® is a registered tracemark and 13TM aid Stop-Drop 'N Lock.Tm are trademarks of Honeywell Intarnatiorial inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be -jsed for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. • , We cannot cover all specific applications or anticipate all requirements. 8illN1 & MANEICTIRIN All specifications are subject to change without notice. QUALITY SYSTEMS Man in the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52521 :B1 • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 . Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models 2W-B, 2W1-B, 4W-B and 4WT-13 photoelectric type smoke detectors. Models 2W-B and 2W1-B are 2-wire and model 4W-B and 4W1-B are 4-wire detectors. Models 2WT-B and 4W1-B employ a thermistor type heat sensor (1350F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ç1JDUAL I°D EDWARDS Catalog Intelligent Input-Output [1FF SAFETY INCIDENT MANAGEMENT Releasing Module SIGA-REL Patented FM 7300-1657: 0205 53424 Overview The SIGA-REL is an analog addressable module that communi- cates directly with the fire alarm panel Signature loop controller. The SIGA-REL controls sprinkler, pre-action and deluge systems, and may also be used to release extinguishing agents such as 002, Halon, or foam. The module is easily configured in the field and offers a wide range of options that ensure dependable service, while preventing the unnecessary release of extinguishing agent. In addition to being an intelligent network component, the SIGA-REL interfaces with a number of conventional devices. These provide manual actuation of abort, release, and service disconnect functions. Together with the SIGA-REL, they com- prise a complete fire suppression package. There is no need for a separate releasing panel because the SIGA-REL takes full advan- tage of the existing control panel communications infrastructure. This ensures low-cost installations with all the be'iefits of Signature Sees analog initiation and control. Seven on-board circuits provide added flexibility. Each SIGA-REL hosts: Two supervised Class B release circuits Two supervised Class B pre-release NACs One supervised Class B manual release input circuit (latch- ing) One supervised Class B abort circuit for normally-open abort switch (non-latching) One first alarm output relay (Form C contact) The SIGA-REL also includes a series of built-in timers that deter- mine the duration of abort routines and release sequences. These timers are easily configured in the field and provide a highly flexible range of options. Standard Features Ideal for sprinkler, pre-action and deluge systems Suitable a wide range of sprinkler applications and extinguish- ing agents such as CO2 and Halon. Built-in timers Selectable durations for abort, manual, and automatic delays. Four abort modes Field-configurable abort routines determine how the timers operate when the abort function is initiated. Supervised circuit-y you can rely on Two Class B release circuits and two pre-release circuits pro- vided. Manual operation keeps ultimate control in plain view The SIGA-REL featLres a manual release input circuit as well as a manual abort input circuit. Fully automated response leaves nothing to chance This module's Form C relay is ideal for room preparation rou- tines. Automatic device mapping simplifies installation Signature modules :ransmit directly to the loop controller their circuit locations with respect to other Signature devices on the wire loop. Page lof8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 Application Understanding fire suppression Fire suppression today is an important part of a growing number of life safety installations. With an ever-increasing reliance on mis- sion-critical computer systems and record high capital investment in high-tech production facilities, businesses large and small are looking for a means of protecting their investments and ensuring a fire won't cripple their operations. While fire detection remains the first line of defense against the risks of fire to people, building owners are looking to fire suppres- sion as a means of protecting their property and assets. But it's a well known fact that fire suppression is a double-edged sword: water can snuff out a mission-critical computer system as easily as it can a fire. Alternatives to water, including carbon dioxide and other extinguishing agents can endanger lives, while the release of even the most inert extinguishing agents can disrupt operations and cost millions of dollars in down-time and lost production. Understanding the SIGA-REL The SIGA-REL Releasing Module is a network component that provides control for fire suppression routines. It fulfils much the same purpose as a standalone releasing panel, but supports Signature Series detectors as an integral part of the suppression system. The SIGA-REL is easy to set up and accepts program- ming via the control panel's SDU Rules Editor. The diagram below represents typical application of the SIGA-REL. The explanations that follow summarize each element of the module. Fire alarm control panel ® Signature Series smoke detectors Signature loop controller , Signature Series modules Horn circuit 1-11,171 - [hIM Strobe circuit SD Service Disconnect Station A Manual Abort Station [IiiI] Manual Release Station 2 First Alarm Output Relay M 1 SD RELA-EOL H Release Circuit I Releasing Module SD RE-EOL H Release Circuit 2 A MR Release Circuits. The SIGA-REL includes two super- vised release circuits, each of which provides fire suppression control to different areas of a protected space. The releasing circuits actuate solenoids on the suppression agent tanks ac- cording to pre-defined release routines. These solenoids release the agent into the protected area. Both circuits operate together A primary goal of any fire suppression system is to prevent the release of extinguishing agent unless it is absolutely necessary. There is no margin for error. But no matter what measures are taken to prevent the unwanted release of extinguishing agent, the fact remains that no suppression system is any better than the detectors it relies on for input. The foundation of an effective sup- pression system, therefore, rests firmly on the quality and reliability of its smoke detectors. Signature Series detectors form an integral part of the suppres- sion system built around the SIGA-REL releasing module. These detectors provide unsurpassed reliability and immunity from false alarms. The SIGA-REL is engineered to the same exacting stan- dards of quality and performance. With a robust set of features designed to eliminate any unwanted release of extinguishing agent, the SIGA-REL provides all the benefits of a dedicated re- leasing panel without the extra expense, and equally important, all the proven advantages of the Signature Series family of products. I I First Alarm Relay. This on-board relay provides a Form C contact that activates at the first alarm input or manual release. The relay is typically used for room preparation such as controlling fans and dampers in advance of the release of suppression agent. I )(I I II Pre-release. Pre-release circuits are used to provide power to notification appliances located within the protected are. Two supervised pre-release circuits are provided: one (steady) for visual notification appliances, and one (pulsed) for audible notification appliances. The pre-release circuits activate with the start of the automatic delay timer. MR Manual Release. The manual release circuit is used to acti- vate the suppression system by means of a connected normally- open release station. This initiates the manual release sequence according to a pre-defined routine. The manual release circuit is supervised and latching. Input from this circuit is processed at the module - communication with the control panel is not neces- sary. A Abort. The abort circuit is used to prevent the release of agent into the protected area after the release sequence has be- gun, but before the automatic delay timer expires. A connected normally-open release station provides manual control over this circuit. The abort circuit is supervised and non-latching. SD Service Disconnect. The service disconnect switch is used to temporarily disable the fire suppression system. There is no dedi- cated circuit for this switch. Instead, it is installed on both release circuits between the SIGA-REL and the RELA-EOL end-of-line relay. Opening the Service Disconnect Switch allows the fire alarm system to be tested without activating the fire suppression system. The operation of this switch causes a trouble signal at the control panel. a ii Data. The Signature data circuit provides an input and an output to the data loop that communicates with the Signature loop controller at the control panel. The SIGA-REL resides on the same data loop as the Signature Series detectors that initiate the automatic release sequence. This close association offers the most reliable performance and ensures compliance with prevail- ing life safety codes. Power. The SIGA-REL requires 24 Vdc (power limited). See the specification table for details. Page 2 of 8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 Operation The SIGA-REL has several built-in safeguards to prevent the un- wanted release of extinguishing agent. All release sequences are subject to configurable delay timers that provide the opportunity for an occupant of the area to manually abort the release se- quence. If no abort signal is received before the delay timer expires, the suppression agent is released. The SIGA-REL includes three delay timers: one for manual release sequences (up to 30 seconds); one for automatic release se- quences (up to 50 seconds); and one for abort sequences (10 seconds). Normal State In its normal operating state the SIGA-REL supervses both of its release circuits and both of its pre-release NAC circuits for faults. Should a short or open occur on any of these circuits, a Trouble condition is reported to the control panel. A trouble condition on any of these circuits may prevent the op- eration of that circuit, but it won't inhibit the operation of any other fault-free circuit. Manual Release Sequence The operation of a manual release station initiates the manual release sequence. The diagram below outlines the manual release sequence. Time Line (see details below) First alarm relay Manual delay timer Pre-releasa circuits I Release circuits i*— delay time - Manual release activated ------------------------1 (01030 saconda) Agent release ______________________________________________________ Syolem reset (manually at the control panel) -------------------------- Note: A manual release sequence cannot be aborted. Manual Release Time Line o An active manual release station disables automatic operation and the abort function and simultaneously activates the: Manual delay timer Pre-release circuit Pre-release strobe circuit (steady On) Pre-release horn circuit (60 pulses per minute) Note: Misapplication of the SIGA-REL can have serious conse- quences. Descriptions provided here are for information only, are subject to change, and should not be used as a guide to field installation of equipment. Always consult the SIGA-REL installation manual when setting up or configuring this component. Automatic Release Sequence The automatic release sequence requires an AND group (cross zone) or a matrix group (counting zone). AND groups and matrix groups require fire alarm signals from designated Signature Series devices. These logic groups are programmable through a laptop computer and the System Definition Utility (SDU). Note: EST2 systems do not support matrix groups. See Program- ming the SIGA-REL for AND group rules. To create AND groups and matrix groups, see the System Programming Manual and the SDU Online Help for your system. The diagram below outlines the automatic release sequence. Time [Line (we details balm) > 0 0 0 0 First aloes relay Automatic delay timer I Pro-release circuits I Release circuits First alarm ------------------------------------4— dalayrnra -* I Active signal from AND group (e.g.: Second aloes ro to 50 saoanda))----. Agent releas- ------------------------------------------------------ Systanrreset ----------------------------------------------------------------------------------- Automatic Release Time Line 0 A detector signals the first alarm. This event simultaneously activates the: First alarm relay Pre-release strobe circuit (steady On) Pre-release horn circuit (15 pulses per minute) O A detector in the protected area signals a second alarm and meets the AND group conditions.* The automatic delay timer then starts its countdown and the pre-release horn circuit changes to 60 pulses per minute. * AND group and matrix group conditions depend on programming. 0 Ten seconds before the expiration of the manual delay timer, the 0 10 seconds before the automatic delay timer expires, the pre- pre-release horn changes from 60 pulses per minute to steady On. release (horn) circuit changes to steady On. 0 The manual delay timer expires and the release circuits activate. O A manual reset at the fire alarm control panel deactivates the release solenoids and the Releasing Module returns to the normal state. 0 The automatic delay timer expires and the release circuits activate. O A manual reset at the fire alarm control panel deactivates the release solenoids and the Releasing Module returns to the normal state. Page 3of8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 Abort Sequences The SIGA-REL provides four abort modes. Aborts do not terminate the release of fire sup- pression agents. They merely offer a limited extension of the automatic timer delay period. Abort Mode 1 (factory default) If the abort is initiated before the automatic time delay expires, it will prevent the releasing action. The automatic delay timer will continue to run while the abort is active. When the abort switch is restored, the release will occur with the expiration of the automatic delay timer or the abort delay timer, whichever occurs last. Abort Mode 2 If the abort is initiated before the automatic time delay expires, it will prevent the releasing action. The automatic delay timer will stop running. When the abort switch is restored, the automatic delay timer will continue from the stop point and the release will occur with the expiration of the timer. Compatibility Sprinkler systems The SIGA-REL works with two types of sprinkler systems: deluge and pre-action. The primary difference between both systems is the type of sprinkler head (or nozzle) that terminates the pipes. Ta- blel-1 outlines the Factory Mutual Research Corporation (FMRC) requirements for deluge and pre-action systems. FM approval requirements for deluge and pre-action sprinkler systems Standby operation 90 hours Alarm operation 10 minutes NFPA style Class A (Style D or E) or Class A (Style 2, 5,6,0r7) FMRC documentation FMRC Approval Guide (Volume 1) Deluge sprinkler systems In Deluge sprinkler systems, open-valve sprinkler heads terminate pipes connected to a water supply controlled by a single valve. When the system detects a fire it automatically opens the valve to allow the waterfiow through all of the sprinkler heads. Deluge sprinklers are useful for applications that require the simultaneous discharge of water through every sprinkler. The following fire detection systems meet FRMC requirements for deluge systems: Wet pilot sprinkler line Dry pilot sprinkler line Hydraulic rate-of-rise Pneumatic rate-of-rise Electric Pre-action sprinkler systems In Pre-action sprinkler systems, closed-valve sprinkler heads ter- minate pipes connected directly to a water supply. The water sup- ply is usually in the same area as the sprinklers and the pipes are supervised for air pressure. Pre-action sprinklers are useful where it is important to prevent the accidental discharge of water. Abort Mode 3 Industrial Risk Insurers (IRI) Mode: To be recognized as valid, the abort must be active when the second alarm is received. When the abort switch is restored, the release will occur with the expira- tion of the abort delay timer (set for 10 sec). Abort Mode 4 International applications: If the abort is initiated before the auto- matic time delay expires, it will prevent the releasing action. The automatic delay timer will stop running. When the abort switch is restored, the automatic delay timer will reset and commence time from t = 0. The release will occur with the expiration of the timer setting minus 10 seconds. The following fire detection systems meet FRMC requirements for pre-action systems: Hydraulic rate-of-rise Pneumatic rate-of-rise Electric Automatic fire extinguishing systems Automatic fire extinguishing systems automatically detect and extinguish fires. They require no manual input because detectors automatically activate releasing solenoids or sprinkler valves. The table below provides a list of the fire suppression agents and the applicable NFPA documents. Fire suppression agents and NFPA documentation Agent NFPA documentation Low-expansion foam NFPA 11 Medium- and high-expansion foam NFPA 1 1 CO2 NFPA 12 Sprinklers NFPA 13 Water spray NFPA 15 Foam-water NFPA 16 Dry chemicals NFPA 17 The table below outlines the FMRC requirements for automatic fire extinguishing systems. FM approval requirements for automatic fire extinguishing systems Standby operation 24 hours Alarm operation 10 minutes NFPA style B or D FMRC documentation FMRC Approval Guide (Volume 1) Warning! Improper applications of fire suppression agents can lead to property damage, injury, or loss of life, consult the applicable NFPA documents and the authority having jurisdiction (AHJ) for more information. Page 4 of 8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 Wiring Abort circuit Manual [5] [3] 14] release circuit 18, First alarm output (9) 1234 1233 24 Vdc In TB3 TB2 2 ~t 24 Vdc out + E L Releasing Module Li1*1**J.I.1 TB4 [ ir 1 TB5 1234 1234 - + - + - + - + Data Circuit In) Out I Note:A maximum of 10 SIGA-REL modules are supported per loop. Compatible panels. The SIGA-REL is compatible with iO Series, EST3 and EST3X fire alarm control panels. You may install the SIGA-REL in any of the following enclosures: 2-W13 series • 2-CAB series 3-CAB series • RACCR series MFC-A • APS6NAPS1OA Note: Maintain a 1-inch (25.4 mm) minimum clearance all around the SIGA-REL. The clearance space must also com- ply with the National Electrical code. Power supplies. The SIGA-REL is compatible with the following power supplies: 2-PPS(-220) • 2-PPS/6A(-220) SIGA-APS(-220) • 3-13PS/M 3-PPS/M • BPS6*, BPS1 0, APSxA *Not compatible with FMRC sprinkler applications that require 90 hours of standby. Solenoid polarizing relays. Use the RELA-EOL with the SIGA-REL. For more information, see the RELA-EOL installation sheet. [1 [2] [7i [8] Service -- Disconnect Switch—, Release circuit 1 RELA-EOL o 3 F[6 Abort stations. The SIGA-REL is only compatible with normally-open, momentary-action abort sta- tions. Abort stations must be listed with the appro- priate agencies in your area. See Listing agencies. Service disconnect stations. The SIGA-REL is only compatible with service disconnect stations that are normally-closed (minimum 2.0 Amps). Service disconnect stations must be listed with the appropriate agencies in your area. See Listing agencies. Releasing solenoid valves. Releasing solenoid valves must be listed with the appropriate agencies in your area. See Listing agencies. Listing agencies. Listing agencies include: Factory Mutual Research Corporation (FMRC) Underwriters Laboratories, Inc. (UL) Underwriters Laboratories Canada (ULC) Switch Settings Abort mode and time delay settings are configured by means of dip switches on the module. Abort mode Mode SW1 SW2 Ulfl3l 1 0 0 Routines that determine how 2 0 1 the abort function interacts 3 1 0 with the timers. 4 1 1 Manual time delay (seconds) Delay SW3 SW4 0 0 0 The length of time that the UJLUI 10 0 1 deluge is inhibited when the 20 1 0 releasing function is manually 30 1 1 initiated. Automatic time delay (seconds) Delay SW5 SW6 SW7 10 0 0 0 The length of time that 20 0 0 1 the deluge is inhibited 30 0 1 0 when the releasing func- 40 0 1 1 tion is initiated by the fl153 50 1 0 0 control panel (i.e.: after receiving an alarm). Abort time delay (seconds) Delay SW8 0 0 The length of time that the deluge is O1L3' 10 1 inhibited when the abort function is restored (i.e.: cancelled). MOO, Denotes default settings. Pro-release Circuit 2 (visual) (steady) 18)[5] [2] Pie-release Circuit 1 (audible) (pulsed 15/60/Steady) [8] (5) (23 LED Operation LED Color Pattern Function DS1 Red Flashing Data (alarm conditions)* DS2 Green Flashing Data (normal conditions)* DS3 Red Steady Alarm DS4 Green Steady Power DS5 Yellow Steady Abort DS6 Yellow Steady Trouble 15S-7 Red Steady Release Active *Note: During a loss of communications, the Releasing Module will go into a standby condition, which will cause DS and DS2 to change to a steady pattern during an alarm condition. Mounting MFC.A Releasing Module #6-32 self-tapping : 74 F: Wale: screws [1](2] [7](8] Service )lsconne Switch Release circuit 2 RELA-EOLl I RELA-EOL RELA-EOL RELA-EOL N Four RELA-EOLs per circuit, max. Class B, 24 Vdc output Class B, normally-open manual release station Class B. normally-open abort station Listed 47 kO EOL resistor Nonpolarized valve. The releasing solenoid valve wiring is not supervised for wire-to-wire shorts. Run the connection to the valve in conduit within 20 feet of the RELA-EOL Solenoid Polarizing Relay. [7) Polarity of circuit shown In supervisory state. On alarm, polarity reverses. [8] Supervised and power-limited. 191 Power-limited when connected to a power- limited source. If nonpower-limited, maintain 1/4 inch (6.4 mm) separation. Otherwise, use FPL, FPLR, or FPLP in accordance with the National Electric Code (NEC). Destroy power-limited markings. 10 Installations, which include other wiring, require FPL, FPLR, FPLP, or equivalent NEC-approved wiring for all power-limited wiring. Page 5 of 8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 Release sullen (rear 40101 Accessories Typical application of SIGA-REL accessories (computer room) Signature Series smoke detectors Ant Fire alarm control pane release nozzle Signature loop oont7roller -------------------------------------- Abort II Release I Station Station r. Release circuit 1 Releasing Module jH Disconnect H RELA-EOL (mounted in MFC-A cabinet) j.... Service - RELA-EOL circuit 2 2 I Extinguishing agent storage cylinder Raised floor Signature Series smoke detectors —(] Agent release nozzle Slab Manual Release Station II The manual release station is a normally-open, dry contact signal initiating device. The 276A-REL is a single-action station that requires the user to pull the release handle to initiate the release of a fire sup- pression agent. The 278A-REL (shown) is a double-action station that requires the user to raise the upper door, then pull the release handle to initiate the release. Front View Semi-Flush Surface SOlE 2-UI' . QV nsn.rn lea,.,,> r I lIfr1 II Lid / L 4 4 square bankbe, end With 2758.R55 Idusler euver xiii, angle B.ckboo gong opening honing overall min. depth of 2-114 (slnnm) Abort Station IRELEASE ABORT al_1441 Md" I -gong (124 nurn) box The abort station is a normally-open, non-latching device. It is used to prevent the release of agent into the protected area after the release sequence has begun. Service Disconnect Switch 3251n, 1.62h 2.25 in. l_101 nvm (67 minn) 7l a deep 24 marn) box The service disconnect switch is used to temporarily disable the fire or - Endr-uel easy ,elrliow) The End-of-Line Relay facilitates the connection of a non-polarized releasing solenoid to a supervised, polarized releasing circuit. One relay is required per release solenoid. Module Enclosure TT , ,,,... - - The MFC-A cabinet is UL-listed ,...13 for use with Signature modules. Shown here with plug-in style I/O modules, the MFC-A also meets UL requirements for spacing and clearance around the SIGA-REL Releasing Module. The cabinet features red epoxy finish with white "FIRE" markings. suppression system. One switch is installed on each of the two release F I I n4o,olde4ce circuits between the SIGA-REL and the RELA-EOL end-of-line relay. To next device or Opening the Service Disconnect Switch allows the fire alarm system and line resistor to be tested without activating the fire suppression system. The : connected :reopen operation of this switch causes a trouble signal at the control panel. End-of-Line Relay Page 6 of 8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 Specifications Input voltage 24 Vdc (power limited) Supervisory current Power riser 25 mA, max. Riser input current 4 amps maximum Alarm 170 mA mm.; 4 A max. Output rating 2 A @24 Vdc (for each Valves per circuit circuit) Release Max. supervisory current 4 valves, max. circuits Nominal supervisory current 0.4 mA (short circuit) Supervisory voltage 0.18 mA End of line device 26 Vdc, max. (open circuit) 47k Ohm EOL Output rating 2 A @24 Vdc (for each Pre-release Max. supervisory current circuit) 0.4 mA (short circuit) alarm circuits Nominal supervisory current Supervisory voltage 0.18 mA 26 Vdc, max. (open circuit) End of line device 47k Ohm resistor Max. supervisory current 0.4 mA (short circuit) Manual Nominal supervisory current 0.18 mA release input Supervisory voltage 26 Vdc, flax. (open circuit) circuit End of line device 47k Ohm resistor Circuit type Class B N.C. latching Circuit capacitance 0.1 lJF, max Max. supervisory current 0.4 mA (short circuit) Nominal supervisory current 0.18 mA Abort circuit Supervisory voltage 26 Vdc, max. (open circuit) End of line device 47k Ohm resistor Circuit type Class B N.C. non- latching Circuit capacitance 0.1 pF, max First alarm Contact rating 3 A @ 24 Vdc output relay (0.6 power factor) Form C Signature Operating voltage 5.2 to 19.95 Vdc Data line Supervisory current 1000 pA Alarm current 1000 pA Operating temperature 32° F to 120° F Environmental (0° C to 49° C) condiltions Storage temperature -4° F to 140° F (-20° C to 60° C) Humidity 0 to 93% Non-condensing Wiring Terminals Suitable for #18 to #12 AWG (2.5 mm2 to .75 mm2) Type Code Factory Set Addressing Uses six module addresses Requirements Agency UL, ULC, and FM Listings Compatible Must be both UL/ULC-listed and FM-approved Solenoids Note: Output circuits are power-limited when the riser circuit is power-limited Line Resistance Power riser Total riser Distance from SIGA-REL to power supply Wire resistance current (Amps) #12 AWG 2.5 mm 2 #14 AWG 1.5 mm 2 (Ohms per wire) 4.0 29 ft 8.84m 20 ft 1 6.10m 0.050 3.5 34 ft 10.36m 23ff 7.01 m 0.057 3.0 39 ft 11.89 m 27 ft 8.23 m 0.067 2.5 47 ft 14.33 m 32 ft 9.75 m 0.080 2.0 59 ft 17.98m 40 ft 12.19m 0.100 1.5 78ff 23.77m 53ff 16.15m 0.133 1.0 118ff 35.97 m 80 ft 24.38 m 0.200 Pre-release and release circuits (per circuit) Total riser Distance from SIGA-REL to power supply Wire resistance current #12 (Amps) I AWG 2.5 mm2 #14 AWG 1.5 mm2 (Ohms per wire) 2.00 176 ft 53.64m 120 ft 36.58m 0.300 1.75 202 ft 61.57m 137 ft 41.76m 0.343 1.50 235 ft 71.63m 160 ft 48.77m 0.400 1.25 282 ft 85.95m 192 ft 58.52m 0.480 - 1.0 353 ft 107.59m 240 ft 73.15m 0.600 0.50 706 ft 215.19m 480 ft 146.30m 1.200 Ordering Information Model - - - Description Ship Wt. lb (kg) SIGA- REL Analog addressable releasing module 0.52 (0.23) Manual releasing station (single-action). 276A-REL English markings, black text on yellow 1.0 (0.45) polycarbonate body. Manual releasing station (double-action). 278A-REL English markings, black text on yellow 1.0 (0.45) polycarbonate body. RELA- Manual Abort Station. English markings, ABT black text on yellow polycarbonate body. 1.0 (0.45) RELA- Service Disconnect Switch. One n/c contact SRV-1 and one n/o contact. English markings, white 1.0 (0.45) text on blue polycarbonate body. RELA- Polarized end-of-line relay. English markings EOL on stainless steel cover. 0.2(0.1) UL listed cabinet for mounting releasing MFC - A modules, red with white "FIRE". 7.0(3.1) HWD:8"x14"x3½" (203mm x 356mm x 89mm) Page 70f8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 8of8 DATA SHEET E85001-0531 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE (§ LISTING No. 7300-1076:0144 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, 1NC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrilI.garIandkidde-fenwal.com DESIGN: Control Unit Accessories. Refer to listee's data sheet for additional detailed system description and operational considerations. Models 70-407008-001 and 70-407018-001; normally-open contact input devices Models 70-407008-002 and 70-407018-002; normally-closed contact input devices Models 70-408004-001 and 70-408014-001; addressable relay output devices Model 30-472001-000; remote trouble indicating panel Model 74-200041-001; limiting resistor Models 74-200012-001, 74-200012-002 and 74-200012-004; loop isolators Models 89-100081-001 AIM (AnaLASER Interface Module) and 89-100083-001 IIM-2000 (Stand Alone) Models 70-200200-001 and 70-200200-003 ASM (Addressable Signal Sounder Module), 73-100001-003 AAM (Addressable AlarmLine Module), 73-100003-001 MM; NEMA 4 Enclosure, *Models *74800300001, 76-800300-001; RDCM's (Remote Display Control Modules) Models *74.800300.10.1 and *76800300101 RDM (Remote Display Modules) Enclosures Models 74-300004-032 and 76-200004-032 ATM-L; (Annunciator Driver Modules) Models 74-300005-032, and 76-200005-032 ATM-R; (Relay Driver Modules) Models 74-100017-001, 76-100010-001, 74-600000-014, and 74-600000-514; Battery Boxes. Models 74-600000-006, 74-600000-516 and 76-600000-006 Fiber-Optic Converter Cards (0CC) Models 06-220171-001 thru -007; Compensating Resistors. Models 70-600000-001 and 70-600000-002; Remote Releasing Modules Models 30-330002-001 and 84-330002-001; Addressable Manual Pull Stations. For indoor use with Model SGB-325 back box or outdoor use with SGB-32C back box. RATING: Electrical: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: *Listed as control unit accessories for use with listee's separately listed ire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 08-20-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, nstallation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:0120 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, 1NC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garlandkidde4enwaI.com DESIGN: Models P/N 30-232001-001 front panel w/cutout for audible and P/N 30-232001-002 front panel w/o cutout for audible. These units have a manual release switch and abort switch. Models 878752-011-02, 30-193000-001I-002 abort stations. Models 296105, 30-193000-003 back boxes. Models 30-322003-003, 84-322003-003 Remote Display Unit Backbox. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, and UL label. APPROVAL: Models 30-232001-001 and 30-232001-002 are listed as control unit accessories when used in conjunction with listees' separately listed fire alarm control units. Models 878752-011-02, 30-193000-001/-002 abort stations and Models 296105, 30-193000-003 back boxes are intended for use with listed releasing device control units. Rev. 06-21-2003 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division f SYsTE1 Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features F I U E Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Aciencv Listinas SIGNAUNG 0 LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT reodels 7135-1653:0503 3057383, 3057072 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AV00665-05 • 2/22/2018 • Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts, Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6' L x 4.7-W x 1.91 D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7'W x 1.25'D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133 mm Lx 88 mm W x 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22)2018 • Page 2 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 DC Input 8-17.5 Volts lscd 30cd 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.lKTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AV05865-05 • 2/22/2018 • Page 3 L-Series Dimensions 1.91,k— — 346 1111111 48.5 11M 88 mm 1.25' 3.46• 88 MM - t25 - 3.57 - I I 1.55' 32 mm (9.1 cm) (3.9 cm) 32 mm r'r up 5.27" '455' I 133.9 mm 5.27' 5.38" 0 DiI Li 133.9mm __ L A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70' (11.94 cm) 5.67' (14.4 cm) I 1.91' (4.85 cm) 1.25' (3.18 mm) tflN ji A0550-00 A0549-00 A0554-01 Strobe, Horn Strobe Horn Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 f Is act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P41FIL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT HRL° Horn, Red HWL* Horn, White HGRL° Compact Horn, Red HGWL° Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. °Horn-only models are listed for wall or ceiling use. STEM 3825 Ohio Avenue • St. Charles, )L 60174 02018 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensorcom for current product information, including the latest version of this data Sheet. www.systemsensor.com AV0S865-05 • 2/22)2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. 7125-1653:0188 Page 1 of CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave. St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall, SA-WBBC (Ceiling) and *SA..\BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This lising is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to veify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions aid/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT Model 5208 KNIGHT Fire Alarm Control Panel with Digital Communicator by Honeywell The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones Supervised zone expanders and I/O modules can be mounted remotely from the main control panel Event History Buffer (150 events) with date/time stamp All zones are compatible with 2- or 4-wire detectors 8 selectable/programmable output patterns for notification appliance circuits Built-in Digital Alarm Communicator Transmitter (DACT) 4 Notification Appliance Circuits 4 programmable general purpose relays Programmable smoke verification, pre-alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms Programmable from the built-in control panel touchpad, remote annunciator, or Windows® SKSS downloading software Direct connect port for on-site up/downloading with Windows® SKSS downloading software Built-in walk test feature Single or dual interlock water releasing capability Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Programmable AC trouble relay Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® Programmable date settings for Daylight Saving Time Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 10 - 93% noncondensing Optional Accessories SK-5235 LCD Remote Annunciator SK-5217 10 Zone Expander (2 max. per system) SK-5280 Status Display Module (8 max. per system) 5220 Direct Connect Module 5824 Serial/Parallel Printer Interface Module SKSS Downloading Software SK-5208 Plex-2 Door Option SK-SCK Seismic Compliance Kit Listings and Approvals UL Listed CSFM Listed MEA approval 429-92-E Vol. XIII OSHPD (CA) OSP-0065-10 Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line I Telephone Line 2 2 Class A(Style D) or Class B (Style B) Initiation Circuits 8 Class B (Style B) Initiation Circuits Direct Connect - For On-Site Programming .—...t Programmable Form C Relays .....4,. Notification Appliance Circuits Annunciators 5235 Remote SBUS Devices 5280, 5217, & 5824 To AC This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev E subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, by Honeywell Fax: (203) 484-7118. For Technical support, Please call 800-446-6444. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0137 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Model SK-5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterfiow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5K5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 61: 71 ~ 5 YTEW! ~~# 5HNgam 0 Photoelectric Smoke Detectors System Sensor j3" series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® LISTED S911 Installation ease. The il line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base.The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock action, Intelligence. il detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (j) Smoke Detector Specifications Smoke detector shall be a System Sensor j3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @24 V Peak Standby Current 2-wire: 100 MA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Dimensions (including base) 5,3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2VVT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4VVT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RI SENS-RDR Sensitivity reader A77-AB2 Removal / replacement tool Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter ll— SENSOR Phone: 0200 System Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 800-SENSOR2 . Fax: 630-377-6495 current CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev©honeywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-13 and 2WT-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2WT-13 and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division