Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; 200; FPC2019-0213; Permit(Zity of 111 Carlsbad Print Date: 04/20/2022 Job Address: 2200 FARADAY AVE. # 200, CARLSBAD, CA 92008-7233 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121206000 Track #: Valuation: $1,256,700.20 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: CAL AMP -FIRE ALARM TI TO EXISTING SYSTEM (35 DEVICES) Permit No: FPC2019-0213 Status: Closed - Finaled Applied: 09/11/2019 Issued: 10/03/2019 Finaled Close Out: 11/21/2019 Inspector: Final Inspection: FPContractor: HCI SYSTEMS INC 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 (909) 628-7773 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov F F C- 2-C) 19 02,13 HC Systems Inc. FIRE I LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: Cal Amp TI 2200 FARADAY AVEMUE, SUITE 220, CARLSBAD, CA 92008 Ontario • San Diego • Irvine • Hayward • Burbank • Fresno • Sacramento Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Website: www.hcisystems.net Cal Amp TI 2200 FARADAY AVEMUE, SUITE 220, CARLSBAD, CA 9200 Manufacturer Device Model # Description C.S.F.M. # WHEELOCK PS-84P Fire Alarm Booster Power Supply 7315-0785:0167 SILENT KNIGHT SD505-PHOTO Photoelectric Smoke Detector 7272-0559:0178 WHEELOCK DSM-12/24-R Sync Input Signal Module 7300-0785:0132 WHEELOCK STWC Multi-Candela Strobe 7125-0785:0168 WHEELOCK HSWC Multi-Candela Horn/Strobe 7125-0785:0168 WHEELOCK ASWP-24MCWH-FW Multi-Candela Horn/Strobe Weater Proof 7125-0785:0131 C4 POWERPATH NAC Power Supply Description remote power supply/battery charger in a low profile cabinet that is used for supervision and expanded power driving capability of fire The Wheelock POWERPATH (PS-8-LP) by Eaton is a supervised alarm Notification Appliance Circuits (NAC). The PS-8-LP is filtered and regulated and provides 8 amps of power distributed across 4 outputs. The power supplies may be connected to any 12V or 24V (FWR or DC) Fire Alarm Control Panel (FACP) by using a NAC or a 'Dry Contact" Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories. This unit provides filtered and regulated 24VDC, up to four (4) Class "B',' two (2) Class "A,' or two (2) Class "B" and one (1) Class "A" Notification Appliance Circuits. With the optional plug-in PS-EXP module the unit supports (8) Class "B" or (4) Class "A' Notification Appliance Circuits. Additionally, an auxiliary power output of 2.5 Amps (disconnected upon AC power loss or an alarm condition) or up to 0.240 A of constant power on the PS-8-LP The Wheelock power supplies can accommodate 7 AH batteries inside its lockable chassis. Using an external battery cabinet it can charge up to 33 AH batteries (pending UL testing). Two FACP NAC circuits or two "Dry" contact initiating circuits can be connected to the inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 3.0 Amps (Class "B") or (Class "A") and can be programmed to generate a steady or Code 3 temporal horn sound and a strobe output under alarm condition. Total load for PS-8-LP NAC circuits must not exceed the power supplies rated output. The power supplies under non-alarm condition provide independent supervision for Class "A' and Class "B" FACP NAC circuits. In the event of circuit trouble, the FACP will be notified via the POWERPATH steered input (INi or 1N2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles. The AC power loss reporting, on the common trouble terminals and on IN1 or 1N2, can be delayed for either 30 seconds or 170 minutes. The AC power loss terminals will always report the trouble within 1 second after loss of AC power. The PS-8-LP power supplies are UL listed under UL Standard 864, 9th Edition to be used with any 24 volt listed regulated notification appliances. They include the capability to synchronize Wheelock strobes and horns and to silence the horn signal when horn/strobes are operating on two wires. Powering Business Worldwide Technical Data TD450003EN Effective October 2017 Features Low Profile Inputs 120VAC, 50/60Hz, 4.25 Amps and 5.32 Amps Operating Power in Alarm 240VAC, 60Hz, 3.22 Amps Operating Power in Alarm 24VDC Battery Backup Connection Two (2), 12V or 24V NAC Initiating Circuits (8-33V at 5mA) FWRorDC Two (2) "Dry" Contact initiating Circuits Accepts two (2) Class "A" or two (2) Class "B" circuit inputs Built in battery charger for sealed lead acid or gel type batteries Outputs NAC outputs are 24VDC, 3.0 Amps each, power limited 8 Amps on PS-8-LP total alarm current Capable of four (4), Class "B" circuits Capable of two (2) Class "A" circuits Capable of one (1) Class "A" circuit and two (2) Class "B" circuits Capable of (8) Class "B" or four (4) Class "A" circuits with optional PS-EXP module Temporal (Code 3), constant voltage output, Wheelock Sync output or True input to output follower mode Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits Input and output can be synchronized with "IN>OUT SYNC" mode (DSM, 2nd POWERPATH or FACP with synchronization protocol is required) Audible silence capability Filtered and electronically regulated output 2.5 Amp auxiliary power limited output with reset capability. (Removed upon AC loss or alarm. Automatic reset 30 seconds after AC power returns or the alarm condition is over) or 0.240 Amps PS-8-LP of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision Compatible with 12V or 24V (FWR or DC) FACP Signaling appliance circuits are supervised and steered to either INi or 1N2 10K Ohm, 1 Watt (Wheelock Model #100651 PSEOL) End of Line Resistor (EOLR) for supervision of all outputs 37 distinguishable trouble diagnostics AC loss trouble reported over a separate set of contacts (delay of 1l second) All troubles are reported over the common trouble contacts (AC loss can have a delay of 30 seconds or 170 minutes) Automatic switchover to standby battery when AC fails Thermal and short circuit protection with auto reset Input and output status LED indicators AC fail supervision Battery presence and low battery supervision Ground Fault Detection, with diagnostics to indicate which circuit fault is on Latching LEDs for NAC trouble annunciation and Diagnostic trouble LEDs (latching can be disabled) POWERPATH NAC Power SupIy Power Not battery dependent Automatic switch over to standby batteries when AC fails Supports sealed lead acid or gel type batteries Fused battery protection Thermal and short circuit orotection with auto reset Supports 7AH batteries Compliance Approvals Include: UL Standard 864, UL 1481 Compliant with NFPA 72 Factory Mutual (FM) Operating Modes (refer to Installation Manual): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input INi or IN2 or by a contact opening on DRY1 or DRY2. The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances. Audibles can also be silenced in this mode while the strobes continue to flash. ln>Out Sync Mode: Accepts a synchronization signal on the input to provide a coded output or synchronized output. This signal may come from a FACE another POWERPATH or a Wheelock DSM synchrorization module. Caution: Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACP another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible aDpliances such as horns, bells or chimes. Caution: Do not use strobes on coded output circuits. 2 EATON www.eaton.com POWERPATH NAC Power Supply Technical Data TD450003EN Effective October 2017 Table 1. Specification & Ordering Information Model Description PS-8-LP. 8 amp power supply, red enclosure, 120V PS-8E-1.0 8 amp power supply, red enclosure, 220V PS-8-B-LP 8 amp power supply, black enclosure, 120V PS-8E-B-LP 8 amp power supply, black enclosure, 240V PS-8-EXP-LP 8 amp power supply with preinstalled expansion module, red enclosure, 120V PS-8E-EXP-LP 8 amp power supply with preinstalled expansion module, red enclosure, 240V PS-EXP 4 class B or 2 class A expansion module Table 2. Specifications Physical Weight PS-8-LP: 11.51bs. (Ship) 9.41bs (Unit); PS-EXP: llb. (Ship & Unit) Dimensions PS-8-LP: 17"H x 13"W x 3.5"D; PS-EXP: 4.3"H x 3.7"W x 11"D Enclosure can house up to two 7 AH batteries Input Circuit Input voltage range 8 to 33 VDC Input Current @ 12 VDC 0.005 amps Input Current @24 VDC 0.005 amps Output Circuit Four (4) Class B or Two (2) Class A or\ 24 VDC @ up to 3 amps per circuit One (1) Class A and Two (2) Class "B" or 8 Class B or 4 Class A (optional PS-EXP module necessary) Continuous duty up to 3 Amps per circuit, up to 4 Amps maximum per panel Standby Current (0,129 Amps) Alarm Current (0.129 Amps Primary PS-8-1-P (I20VAC models) 105 to 130 VAC 50/60 Hz @ 5.32 Amps Primary PS-8-EXP-LP (240 VAC models) 210 to 260 VAC 50/60 Hz @ 3.22 Amps Secondary Power Charging Capacity 32 Amp hours @0.750 Amps per hour Aux Output CP Mode PS-8-1-P up to 250 mA MP Mode 2.5A during non alarm EATON www.eaton.com 3 Technical Data TD450003EN Effective October 2011 Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH PS-8-LP or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" opening. The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class "B two Class "Nor two Class "B" and one Class "A" NAC circuit(s). Eight Class "B" or Four Class "A" circuits shall be available with an optional PS-EXP module. The PS-8-LP unit shall supply up to 240 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. POWER PATH NAC Power Supplies - PS-8-LP Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A'The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class "A" or Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of 5.32 amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max. The power supply shall have the ability to latch trouble LEDs so the circuit in trouble can be identified. The cabinet dimensions shall be 17" H x 13" W x 3.5" D. UL 864, UL 1481, FM Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eatoncom Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/rnassnotificatiorr r5 2017 Eaton F 'IN All Rights Reserved Printed in USA Publication No. TD450003EN Powering Business Worldwide October 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0785:0167, Page 1 of I CATEGORY: 7315 -- POWER UNITS LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models POWERPATH Tm PS-6, *P56B PS-6E, *PS..6E..B PS-8, *PS..8..B PS-8E, 'PS-8E-B, PS-8-LP', *PS..8..B..Lp *pS..8E..Lp and *PS..8E..B..LP remote notification appliance circuit extender power supplies. Model PS-EXP notification appliance circuit extender power accessory. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC for PS-6, *pS..6..B PS-8, *pS..8..B *PS..8..Lp *PS..8..B..LP 240 VAC for PS-6E, *PS6EB PS-8 E, *p58 E-B, *PS..8E..LP and *PS.8E.B..LP INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units and notification appliances. Authority having jurisdiction should be consulted prior to installation. The unit can be programmed to generate the three-pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 edition. *Rev II-03-15gt ss This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 202& Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DI SILENT KNIGHT by Honeywell Addressable Photoelectric Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RE/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model'SD505-PHOTO' - I Analog I Addressable Photoelectric Type Smoke Detector The SD505-PHOTO is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-PHOTO units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved EM Approved Specifications Operating Voltage: 24-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA SD505-PHOTO Smoke Detector Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% non- condensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) SD505-61B 5D505-6RB SD505-6SB PIN 350225 Rev G © 2015 Honeywell International Inc. Diameter = 3-15/16" Height = 2 inches, including base SILENT ENIGHT Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight 5D505-HEAT Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5-15/16" I Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to keep our KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. p7272-0559:0178' Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Model '5D505-PHOTO'analog, photoelectric smoke detector for use with Model SD505-6AB base. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 17.0 - 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as an analog photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units Hochiki Models FireNet Plus (CSFM No. 7165-0410:0180) and FireNet 4127 (CSFM No. 7165-0410:0159). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0410:0204 10-22-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 3O, 2020' Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division j ~ ~4 f , / DSM Sync modules o o o 0 Description The DSM sync modules provide independent operation of synchronized temporal pattern (code 3) horn and synchronized strobe flash, as well as the ability to silence the horn while maintaining the strobe flash (audible silence) while using only a single pair of wires. The DSM-12/24 sync modules control either one (1) Class A or two (2) Class B NAC circuits. When using the low frequency 520 sounder (LFHSK) the DSM can provide the code three temporal (T3) and also the code four temporal (T4) for carbon monoxide notification. DSM Table 1. Products available for use with DSM sync module Model Description AH-WP, HS Audible horn MT with strobe® Multitone horn with sync strobes E and EH with strobe E and El-I HIFI speakers with sync strobe ET70/90/1 080 with strobe ET speakers with sync strobe RSS/RSSP strobes Remote sync strobes CH70 strobes® Chimes with sync strobes AS-WP, HS4 Audible horn with sync strobes LSPST, LHS LED speaker strobes and horn strobes LLFHSK Low frequency (520Hz) sounder strobes ® Strobe portion of device is compatible; audible portion does not synchronize. FM,T* N Powering Business Worldwide Technical Data TD450081EN Wheelock DSM Effective October 2016 Features & benefits Drawings Uniquely designed to accept an independent strobe and audible input from the FACP and convert to a single output that connects to Wheelock compatible appliances. 3 ampere per circuit current handling at 12 or 24 VDC Low operating current draw Compatible with all standard fire alarm control panels Meets the NFPA-72 requirement for Temporal Pattern when used with the Series AS/AH and/or Series Exceder Note: Please read these specifications and associated installation instructions before using, specifying, or installing this product. Visit Eaton.com/massnotification for current installation instructiors. H 4.97 1.34 O[___ 4.97 I A .........._....___I_ __.._.I! _____ MPFOVdI5 ompuuanes Figure 1. DSM front and side views Approvals include UL Standard 1971, ULC, NewYork City (MEA), California State Fire Marshal (CSFM) and Chicago (BFP) General information When calculating the total current, use Tables 1& 2 to determine the highest value of "Rated Average Current" for the SM or DSM (across the listed voltage range), then add this value to the total current for any other appliances powered by the same source and include any required safety factors. Refer to Instruction Sheet for addtional information. Table 2. Sync module (DSM) current requirements (AMPS) UL Voltage ULC Voltage Rated Average Current Rated Peak Current Rated Inrush Current ln1lln2 Audible ln1/In2 Audible lnllln2 Audible 8.0 VDC 10.5 VDC 0.019 0.004 0.055 0.004 0.150 0.016 12.0 VDC 12.0 VDC 0.020 0.004 0.064 0.004 0.170 0.019 24.0 VDC 24.0 VDC 0.035 0.008 0.080 0.008 0.342 0.030 33.0 VDC 33.0 VDC 0.045 0.010 0.090 0.010 0.470 0.040 8.0VRMS 8.0VRMS 0.028 0.005 0.107 0.008 0.210 0.016 12.0 VRMS 12.0 VRMS 0.030 0.006 0.103 0.009 0.240 0.019 24.0 VRMS 24.0 VRMS 0.048 0.010 0.145 0.015 0.480 0.033 33.0 yAMS 31.0 VRMS 0.062 0.012 0.175 0.022 0.685 0.056 Table 3. Current consumption DSM modules Output Circuit Description of DSM Module DSM Module Class "B" with Audible Silence (dual circuit) Y Class "B" with No Audible Silence (dual circuit) Y Class "A" with Audible Silence (single circuit) Y Class "A" with No Audible Silence (single circuit) Y Notes: 1. DSM dual sync modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Non-sync appliances can be installed before or after a DSM. If the non-sync appliance requires audible silence, four wire connection is necessary with the strobe circuit connected before the DSM NAC circuit, and the audible leads connected to a silenceable NAC circuit from the FACP The audible appliance produces a momentary interruption (approximately 25ms) each time the strobes flash. Circuit #2 may be omitted if only 1 circuit is required when using the DSM. Non-sync audible appliances can be installed on the audible NAC. Be aware of the current requirement for the DSM module. See Table 2. 2 EATON www.eauon.com Wheelock DSM Technical Data TD450081EN Effective October 2016 Table 4. Specifications and Ordering Information Model Number Finish Order Code Input Voltage VDC Average Current @ 12 or 24 VDC UL Max® Mounting Options® DSM-12/24-R®® Red 6374 12 0.020 0.026 W 24 0.035 0.055 W ® RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range )16-33v for 24v units). For strobes, the UL max current is usually at the minimum listed voltage )16v for 24v units). For audibles, the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. ® Refer to Data Sheet #TD450028EN for mounting options. ® The total distance from the first to the last DSM shall not exceed 1,000 feet of #18 AWG wire. Use only #18 AWG wire. Architects and engineers specifications The sync modules shall be Wheelock DSM sync modules. Wheelock DSM sync modules shall be the master controllers for Wheelock Execeder (HS), Wheelock Exceder LED (LSPST, LHS), and Wheelock AH-We M1 E, EH, ET70/90/1080, RSS/RSSF and CH70 product lines appliances where a synchronized audible/visual audible or visual only appliance is specified. All modules shall be UL listed under Standard 464. Wheelock DSM modules shall be designed to interface with AS audible strobe appliances and horn strobe appliances to produce a synchronized temporal (Code 3) horn as well as synchronized strobe flash on a two-wire alarm circuit. DSM modules shall provide an additional strobe circuit input/output for control of either two Class "B" NAC circuits or a single Class "A" NAC circuit. Upon activation of the audible silence function at the fire alarm control panel, the audible signal component of AS audible strobes and/or NS horn stobes may be silenced while maintaining strobe activation. When using the low frequency 520 sounder (LFHSK) the DSM shall provide the code three temporal (T3) and also the code four temporal (T4) for carbon monoxide signalling. DSM module shall be DSM-1 2/24 for control of either Class A two (2) Class B NAC circuits. The DSM dual circuit version shall provide the additional capability of "daisy-chaining"—the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. Interconnection capability shall be for a maximum of 40 NAC circuits. All modules shall operate on either 12 or 24 VDC. The DSM 12/24 shall be 0.020 amperes @ 12 VDC and 0.035 amperes @ 24 VDC. The dual circuit DSM sync module shall be capable of handling a load of 3 amperes per NAC circuit at 12 or 24 VDC. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of #18 to #12 AWG wire size. DSM sync modules shall mount to a 4-11/16" x 2-1/8" deep backbox. rMember WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock, Inc. dba Eaton standard terms and conditions. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 wv.eaton.corrrimassnotification © 2016 Eaton E • N All Rights Reserved Printed in USA Publication No. 10450081 EN Powering Business Worldwide October 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-0785:0132' Page 1 of I 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperindustries.com Models SM-I 2/24, SMX-1 2/24,'DSM-12/24'and DSMX-1 2/24 Synchronized Control Modules. Models SM-I 2/24 and DSM-12/24 may be followed by -R, -w, -x or -S. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-33 VDC* INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling appliances accessory for use with separately listed synchronized strobe lights. For indoor use only. *Rev. 05-26-10 bh %, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V%G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 202O Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (c2 Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. F M,TG N Powering Business Worldwide Technical Data TD450049EN Effective November 2016 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 Ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover - Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) 2 EATON www.eaton.com HN Seies HS Sw1th, ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance drawD 12/24VDC on a single appliance Easy to remember model numbers ® Patented Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ mass notification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range': All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPNANSI/OSHA RoHS HN Series H$ Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® Technical Data TD450049EN Effective November 2016 24VDC/24FWR 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn A = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering (strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering (strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering (strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1: STRC = Strobe, Red, Ceiling Mount Table 4. Specification & Ordering lflformation Example 2: HSR = Horn Strobe, Red, Wall Mount Sync w/ DSM Example 3: HSW = Horn Strobe, White, Wall Mount Model Strobe Candela Supplies Power bunting Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering VDC(D Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® HSW 15/1575/30/75/95/110/135/185 X X UMB® : HSRC 15/30/60/75/95/115/150/177 X X UMB® .......... HSWC 15/30/60/75/95/115/150/177 X X UMB® . .,:t W 'J..1 SA Strobes x X UMB® .- L STW 15/1575/30/75/95/110/135/185 X X LIMBO LL STRC 15/30/60/75/95/115/150/177 X X LIMB® LSTWC 15/30/60/75/95/115/150/177 X X UMB® / Horn UMB® Example: HSR Example: HSWC X X UMB® HNWC ® 12 VDC models feature 15 & 15/75 settings ® UMB = Universal Mounting Base EATON www.eauon.com 3 Technical Data TD450049EN HN Series Effective November 2016 HS Sees ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexanw lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shal have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton .com Powering Business Worldwide Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07744 Eaton.com/massnotifbation © 2016 Eaton All Rights Reserved Printed in USA Publication No. TD450049EN November 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:016& Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models'ST strobeHS horn stroband HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) orW (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020' Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Weatherproof appliances Description Designed for life safety, performance and reliability, Eaton's Wheelock cost-effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn strobes 'ASWP Horn AH-24We AH-12WP Multitone horn strobes MTWP Multitone horns MT Speaker strobes ET70WP Speakers ET-101O All strobe models are UL dual listed—meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-35°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). FM,TO N Powering Business Worldwide To enable weatherproof mounting, Eaton provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See Table 10 on page three of this document for a summarization of these mounting options and the required accessories. Al) models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Technical Data TD450041EN Effective September 2017 Features & benefits Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal Note: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Approvals & compliances Approvals include: UL Standards 1971, 1638, 464 and 1480; California State Fire Marshal (CSFM); New York City (MEA); Factory Mutual (FM); Chicago (BFP( and ULC (see agency approvals by model number on pages 4 and 5 of this document) The series RSSWP ASWP AH-24WF MTWP-2475W, and MT-12/24 have UL/ULC approval down to —40°F. The ET-101O and ET70WP have UL approval down to —40°F. The AH-12WP has UL approval down to -31°F Compliance with the following requirements: NFPA; UFC; ANSI 117.1; OSHA Part 29,1910.165; AD General notes Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Models are available in red or white. Contact Customer Service for order code and delivery. Drawings Ii 4.80 0.602 ©FIRE© H 4.80 ©. FIRE ©I LI Figure 1. RSSWP front and side views Wheelock AH, AS, MI, RSS, ET70 4 4.80 2.55_-*1 4.80 Figure 2. ASWP front and side views 5.126 Ilu P0() 0 0.65 Figure 3. MTWP front and side views 5.120 4 5.368 IT 000000000 000000000 5.120 0000uaod- 0 0 Figure 4. ET70WP front and side views 5.13 2.17 000 i 4-4 I 5.13 Figure 5. MT front and side views 2 EATON www.eaton.com vVheelock AH, AS, MT, RSS, ET70 Technical Data TD450041EN Effective September 2017 4.29 -H 4.09 Do = I 4.29 1.92 Figure 6. ET-1010 front and side views Table 1. Maximum UL current for AH models UL Max Current for AH 24V0C I2VDC High(99)dBA 0.080 0.192 Med (95)dBA 0.043 0.108 Low (90) dBA 0.021 0.058 Table 2. dBA ratings for ET-1010 and ET70WP models UL Reverberant dBA @ 10 ft. Watts Model 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 90 93 95 Table 3. Maximum UL current (audible) MTWP/MT 24vDC dBA HI STD MT 12VDC HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Table 4. Candela ratings RSS. ET70WP and MTWP ASWP UL Max Current Series UL 1971 UL 1638 @ 77F UL 1638 @ -40F (strobe only) High Mod low 2475W 30® 180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 IMCWH. 135 135 56 0.300 b.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 115 115 47 0.300 0.355 0.340 0.335 MCCH 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 24177 177 177 73 0.420 @ Wall mount rating only EATON www.eaton.com 3 Technical Data TD450041 EN Effective September 2017 Wall mount models Table 5. Specification and ordering information Model Number Finish T Wheelock AH, AS, MT. RSSIET7O Agency Approvals Order Code UL MEA CSFM FM BFP Strobe RSSWP2475WFR Red 9013 X X X X - RSSWP-2475W-FW - White 3034 X X X X - RSSWP-24MCWH-FR Red 5161 X - X - - RSSWP24MCWHFW r White 5165 X - X - - Audible strobe ASWP-2475W-FR Red 9012 X X X X X ASWP-24MCWH-FR - I Red 5137 x - x - - SWP24MCWFW White 5140 X - X - - Multilane strobe M1WP-2475W-FR Red 8420 X X - X X MTWP-2475W-FW White 3112 X X X X - MTWP-24MCWH-FR Red 5132 X - X - - MTWP-24MCWH-F\N LLJ White 5134 X - X - - Speaker strobe ET70WP-2475W-FR Red 9077 X - X X - ET70WP-2475W-FW : White 3179 X - X X - ET70WP-24185W-FR Red 4885 X - X X - E170WP-24185W-FW - White 4891 X - X X - Ceiling mount models Table 6. Specification and ordering information Agency Approvals Model Number Finish Order Code UL MEA CSFM FM BFP Strobe RSSWP-2475C-FR Red 4338 X x X X - RSSWP-2575C-FW ) White 4446 X X X X - RSSWP-24MCCH-FA F R E( Red 5167 X - X - - RSSWP-24MCCH-FW White 5187 X - X - - Audible strobe ASWP-2475C-FR Red 4251 X X X X X ASWP-2475C-FW I White 4502 X X X X X ASWP-24MCCH-FR Red 5149 X - X - - ASWP-24MCCI-t-FW White 5157 X - X - - Multitone strobe M1WP-2474C-FR Red 4457 X X X X - M1WP-2475C-FW White 4458 X X X X - MTWP-24MCCH-FR 0 F I R E Red 5102 X - X - - MTWP-24MCCH-FW White 5122 X - X - - Speaker strobe ET70WP-2475C-FR Red 4452 X - X X - ET70WP-2475C-FW White 4454 X - X X - ET70WP-24177C-FR Red 4845 X - X X - E170WP-24177C-FW White 4859 X - X X - 4 EATON www.eaton.com WheelockAH,AS, MT, RSS, ET70 Wall or ceiling mount models Table 7. Specification and ordering information Model Number Finish Technical Data TD450041EN Effective September 2017 Agency Approvals Order Code UL MEA CSFM FM BFP Audible AH-24WP-R Red 7416 X X X X X AH-12WP-R Red 7415 X X X X X Horn MT-12/24-R Red 5023 X X X X X Speaker ET1010W White 3137 X X X X X Mounting accessories Table 8. Ordering information Model Number Finish Order Code Model Number Backboxes Gasket kit I0B-R ® Red 5046 WP-KIT I0B-W 0 White 5047 Flush plates WFPA-R Red 4698 - WFPA-W White 4701 Finish Order Code N/A 4486 1.1 WFP-R Red 4696 WFP-W White 4697 WPSBB-R 0 Red 9751 WPSBB-WcD White 3033 WPBB-R 0 Red 9014 WPBB-W® White 4692 Table 9. Mounting options WBB-R Red 2959 Surface Mount Flush Mount WBB-W White 2960 Exposed Mounting Options Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA 0 lOB, WPSBB and WPBB models include weep holes and plug in the event that moisture may have AHWP Horns WBB - WFP entered the appliance. ET-1010 Speakers WBB - WFP MTWP Multitone Strobes lOB lOB + WP-KIT WFP Multitone lOB lOB + WP-KIT WFP Note: Refer to Data Sheet TD450028EN for moutiag options EATON www.eaton.com 5 Technical Data TD450112EN Wheelock AH, AS, MI, RSS, ET7O9° Effective September 2017 Architects and engineers specifications General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit, concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F tc 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eatoncom Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/massnotification © 2017 Eaton F All Rights Reserved Printed in USA Publication No. TD450112EN Powering Business Worldwide September 2017 Eaton is a registered trademark. All other trademarks are properly of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7125:0785:0131: Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock tnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -w are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *Aswp..2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, ASWP-24MCWH and *ASWP..24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires (June 30, 202& Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0131 Page 2of2 * RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd, 1575:15/75cd,30:30cd,75:75cd,95:95cd,100:100cd,1 10:llOcd MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd MCWH: Selectable 135cd,185cd (65cd, 90cd at 40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at-40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-I2WP, AH-24WP, *AswP..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12124, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires 3O,2O2 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division