Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; 220; FPC2018-0098; Permit;J 1:1 tl14Is]4l (ity of Carlsbad Dftc: LkijiijOI Print Date: 04/20/2022 Permit No: FPC2018-0098 Job Address: 2200 FARADAY AVE, # 220, CARLSBAD, CA 92008-7233 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121206000 Track #: Applied: 03/28/2018 Valuation: $166,691.84 Lot #: Issued: 04/19/2018 Occupancy Group: Project #: Finaled Close Out: 09/08/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check #: Final Inspection: Project Title: Description: SPEC SUITE 220 -FIRE ALARM T.I. Applicant: FPContractor: HCI SYSTEMS INC HCI SYSTEMS INC JEFF RODGERS 4585 MURPHY CANYON RD 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 SAN DIEGO, CA 92123-4318 (909) 628-7773 (858) 560-7000 FEE AMOUNT FIRE Reinspection (per inspection) $187.00 FIRE TI Fire Alarm System $601.00 Total Fees: $788.00 Total Payments To Date: $788.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 1 I www.carlsbadca.gov HC1 Lj!Pr Systems Inc. FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: SPEC SUITE 220 2200 FARADAY AVE. CARLSBAD, CA 92008 FPC2018.09 2200 FARADAY AVE #220 SPEC SUITE 220- FIRE ALARM T.I. 2121206000 312812018 FPC20I 8-0098 Ontario • San Diego • Irvine • Hayward • Burbank • Fresno • Sacramento Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Websife: www.hcisystems.net i SPEC SUITE 220 2200 FARADAY AVE. CARLSBAD, CA 92008 Manufacturer Device Model # Description C.S.F.M. # WHEELOCK PS-8-LP Fire Alarm Booster Power Supply 7315-0785:0167 SILENT KNIGHT SD505-PHOTO Photoelectric Smoke Detector - 7272-0559:0178 WHEELOCK DSM-12/24-R Sync Input Signal Module 7300-0785:0132 WHEELOCK STWC Multi-Candela Strobe 7125-0785:0168 WHEELOCK HSWC Multi-Candela Horn/Strobe 7125-0785:0168 POWERPATH NAC Power Supply FM,TON Powering Business Worldwide Description The Wheelock POWERPATH (PS-8-LP) by Eaton is a supervised remote power supply/battery charger in a low profile cabinet that is used for supervision and expanded power driving capability of fire alarm Notification Appliance Circuits (NAC). The PS-8-LP is filtered and regulated and provides 8 amps of power distributed across 4 outputs. The power supplies may be connected to any 12V or 24V (FWR or DC) Fire Alarm Control Panel (FACP) by using a NAC or a "Dry Contact" Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories. This unit provides filtered and regulated 24VDC, up to four (4) Class "B'two (2) Class "N' or two (2) Class "B" and one (1) Class "A' Notification Appliance Circuits. With the optional plug-in PS-EXP module the unit supports (8) Class "B" or (4) Class "A' Notification Appliance Circuits. Additionally, an auxiliary power output of 2.5 Amps (disconnected upon AC power loss or an alarm condition) or up to 0.240 A of constant power on the PS-8-LP The Wheelock power supplies can accommodate 7 AH batteries inside its lockable chassis. Using an external battery cabinet it can charge up to 33 AH batteries (pending UL testing). Two FACP NAC circuits or two "Dry" contact initiating circuits can be connected to the inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 3.0 Amps (Class 'B") or (Class "A') and can be programmed to generate a steady or Code 3 temporal horn sound and a strobe output under alarm condition. Total load for PS-8-LP NAC circuits must not exceed the power supplies rated output. The power supplies under non-alarm condition provide independent supervision for Class "A' and Class "B" FACP NAC circuits. In the event of circuit trouble, the FACP will be notified via the POWERPATH steered input (INi or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles. The AC power loss reporting, on the common trouble terminals and on INi or lN2, can be delayed for either 30 seconds or 170 minutes. The AC power loss terminals will always report the trouble within 1 second after loss of AC power. The PS-8-LP power supplies are UL listed under UL Standard 864, 9th Edition to be used with any 24 volt listed regulated notification appliances. They include the capability to synchronize Wheelock strobes and horns and to silence the horn signal when horn/strobes are operating on two wires. Technical Data 10450003EN Effective October 2017 Features Low Profile Inputs 120VAC, 50/60Hz, 4.25 Amps and 5.32 Amps Operating Power in Alarm 240VAC, 60Hz, 3.22 Amps Operating Power in Alarm 24VDC Battery Backup Connection Two (2), 12V or 24V NAC Initiating Circuits (8-33V at 5mA) FWRorDC Two (2) "Dry" Contact initiating Circuits Accepts two (2) Class "A" or two (2) Class "B" circuit inputs Built in battery charger for sealed lead acid or gel type batteries Outputs NAC outputs are 24VDC, 3.0 Amps each, power limited 8 Amps on PS-8-LP total alarm current Capable of four (4), Class "B" circuits Capable of two (2) Class "A" circuits Capable of one (1) Class "A' circuit and two (2) Class "B" circuits Capable of (8) Class "B" or four (4) Class "A" circuits with optional PS-EXP module Temporal (Code 3), constant voltage output. Wheelock Sync output or True input to output follower mode Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits Input and output can be synchronized with "IN>OUT SYNC" mode (DSM, 2nd POWERPATH or FACP wth synchronization protocol is required) Audible silence capability Filtered and electronically regulated output 2.5 Amp auxiliary power limited output with reset capability. (Removed upon AC loss or alarm. Automatic reset 30 seconds after AC power returns or the alarm condition is over) or 0.240 Amps PS-8-LP of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision Compatible with 12V or 24V (FWR or DC) FACP Signaling appliance circuits are supervised and steered to either INi or 1N2 10K Ohm, 1 Watt (Wheelock Model #100651 PSEOL) End of Line Resistor (EOLR) for supervision of all outputs 37 distinguishable trouble diagnostics AC loss trouble reported over a separate set of contacts (delay of 1 second) All troubles are reported over the common trouble contacts (AC loss can have a delay of 30 seconds or 170 minutes) Automatic switchover to standby battery when AC fails Thermal and short circuit protection with auto rese Input and output status LED indicators AC fail supervision Battery presence and low battery supervision Ground Fault Detection, with diagnostics to indicate which circuit fault is on Latching LEDs for NAC trouble annunciation and Diagnostic trouble LEDs (latching can be disabled) POWERPATH NAC Power SuppIi Power Not battery dependent Automatic switch over to standby batteries when AC fails Supports sealed lead acid or gel type batteries Fused battery protection Thermal and short circuit protection with auto reset Supports 7AH batteries Compliance Approvals Include: UL Standard 864, UL 1481 Compliant with NFPA 72 Factory Mutual (FM) Operating Modes (refer to Installation Manual): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input INi or lN2 or by a contact opening on DRY1 or DRY2. The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances. Audibles can also be silenced in this mode while the strobes continue to flash. ln>Out Sync Mode: Accepts a synchronization signal on the input to provide a coded output or synchronized output. This signal may come from a FACP another POWERPATH or a Wheelock DSM synchronization module. Caution: Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACE another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible a3pliances such as horns, bells or chimes. Caution: Do not use strobes on coded output circuits. 2 EATON w.eaton.com tPOWERPATH NAC Power Supply Technical Data TD450003EN Effective October 2017 Table 1. Specification & Ordering Information Model Description PS-8-LP 8 amp power supply, red enclosure, 120V PS-8E-LP 8 amp power supply, red enclosure, 220V PS-8-B-LP 8 amp power supply, black enclosure, 120V PS-8E-B-LP 8 amp power supply, black enclosure, 240V PS-8-EXP-LP 8 amp power supply with preinstalled expansion module, red enclosure, 120V PS-8E-EXP-LP 8 amp power supply with preinstalled expansion module, red enclosure, 240V PS-EXP 4 class B or 2 class A expansion module Table 2. Specifications Physical Weight PS-8-LP: 11.5Ibs. (Ship) 9.41bs (Unit); PS-EXP: llb. (Ship & Unit) Dimensions PS-8-LP: 17"H x 13"W x 3.5"D; PS-EXP: 4.3"H x 3.7"W x i'D Enclosure can house up to two 7 AH batteries Input Circuit Input voltage range 8 to 33 VDC Input Current @ 12 VDC 0.005 amps Input Current © 24 VDC 0.005 amps Output Circuit Four (4) Class B or Two (2) Class A or\ 24 VDC © up to 3 amps per circuit One (1) Class A and Two (2) Class "B" or 8 Class B or 4 Class A (optional PS-EXP module necessary) Continuous duty up to 3 Amps per circuit, up to 4 Amps maximum per panel Standby Current 0.129 Amps' Alarm Current 0.129 Amps Primary PS-8-LP (120VAC models) 105 to 130 VAC 50/60 Hz @5.32 Amps Primary PS-8-EXP-LP (240 VAC models) 210 to 260 VAC 50/60 Hz @3.22 Amps Secondary Power Charging Capacity 32 Amp hours @0.750 Amps per hour Aux Output CP Mode MP Mode PS-8-LP up to 250 mA 2.5A during non alarm EATON www.eaton.com 3 Technical Data TD450003EN Effective October 2017 Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH PS-8-LP or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" opening. The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class "B': two Class "A ,or two Class "B" and one Class "A" NAC circuit(s). Eight Class "B" or Four Class "A" circuits shall be available with an optional PS-EXP module. The PS-8-LP unit shall supply up to 240 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. POWERPATH NAC Power Supplies - PS-8-L1 Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A':The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class "A" or Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of 5.32 amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max. The power supply shall have the ability to latch trouble LEDs so the circuit in trouble can be identified. The cabinet dimensions shall be 17" H x 13" W x 3.5" D. UL 864, UL 1481, FM Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. 1i1 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mess notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.corrVmessnotification @2017 Eaton E All Rights Reserved Printed in USA Publication No. TD450003EN Powering Business Worldwide October 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0785:016'7 Page 1 of I CATEGORY: 7315-- POWER UNITS LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@coopenndustnes.com DESIGN: Models POWERPATH Tm PS-6, *ps..6..B PS-6E, *ps..6E..B PS-8, *ps..8..B PS-8E, *ps..8E..B tPS-8-LP *ps..8..B..Lp *PS..8E..LP and *PS..8E..B..LP remote notification appliance circuit extender power supplies. Model PS-EXP notification appliance circuit extender power accessory. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC for PS-6, *pS..6..B PS-8, *ps..8..B *ps..8..Lp *PSBLP 240 VAC for PS-6E, *PSE..B PS-8 E, *Ps..8 E-B, *ps..8E..Lp and *PS..8E..B..LP INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units and notification appliances. Authority having jurisdiction should be consulted prior to installation. The unit can be programmed to generate the three-pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 edition. *Rev 11-03-15gt ,T This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell Addressable Photoelectric Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. InteIliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each S0505-PHOTO photoelectric detector has a unique address, which is recognized by the InteIliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the S0505-PHOTO offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model 5D505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. ModeISD5O5-PHOTO Analog I Addressable Photoelectric Type Smoke Detector The SD505-PHOTO is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-PHOTO units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved Specifications Operating Voltage: 24-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA SD505-PHOTO Smoke Detector Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% non- condensing Air Velocity: 0 - 300 FPM Compatible Bases: 5D505-6AB (Sold Separately) SD505-61B SD505-6RB 5D505-6SB P/N 350225 Rev G © 2015 Honeywell International Inc. Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist-lock base 5D505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5-15/16° 14 Diameter = 3-15/16" 4 01 071 0) 7 I •1l 't / Height = 2 inches, including base 1 SILENT1 I_. Model 5D505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more Is information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (-O559:0178 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYI985 Douglas Drive, MNI0-212A, Golden Valley MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model SD505-PHOTOanaIog, photoelectric smoke detector for use with Model S0535-6AB base. Refer to listee's data sheet for additional detailed product descripticn and operational considerations. RATING: 17.0 - 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordrances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as an analog photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units Hochiki Models FireNet Plus (CSFM No. 7165-0410:0180) and FireNet 4127 (CSFM No. 7165-0410:0159). Refer to listee's installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0410:0204 10-22-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This Isting is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (ine 30, 201 8) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division o 0 o 0 DSM DSM Sync modules Description The DSM sync modules provide independent operation of synchronized temporal pattern (code 3) horn and synchronized strobe flash, as well as the ability to silence the horn while maintaining the strobe flash (audible silence) while using only a single pair of wires. The DSM-12/24 sync modules control either one (1) Class A or two (2) Class B NAC circuits. When using the low frequency 520 sounder (LFHSK) the DSM can provide the code three temporal (13) and also the code four temporal (T4) for carbon monoxide notification. Table 1. Products available for use with DSM sync module Model Description AH-WP, HS Audible horn MT with strobe® Multitone horn with sync strobes E and EH with strobe E and EH HIFI speakers with sync strobe ET70/90/1 080 with strobe El speakers with sync strobe RSS/RSSP strobes Remote sync strobes CH70 strobes® Chimes with sync strobes AMP, HS4 Audible horn with sync strobes LSPST, LHS LED speaker strobes and horn strobes LFHSK Low frequency (520Hz) sounder strobes ® Strobe portion of device is compatible; audible portion does not synchronize. IFITO N Powering Business Worldwide Technical Data TD450081EN Effective October 2016 Features & benefits Uniquely designed to accept an independent strobe and audible input from the FACP and convert to a single output that connects to Wheelock compatible appliances. 3 ampere per circuit current handling at 12 or 24 VDC Low operating current draw Compatible with all standard fire alarm control panels Meets the NFPA-72 requirement for Temporal Pattern when used with the Series AS/AH and/or Series Exceder Note: Please read these specifications and associated installation instructions before using, specifying, or installing this product. Visit Eaton.com/massnotification for current installation instructions. Approvals & compliances Approvals include UL Standard 1971, ULC, New York City (MEA), California State Fire Marshal (CSFM) and Chicago (BFP) Wheelock DSM Drawings H cI 4.97 Figure 1. DSM front and side views General information When calculating the total current, use Tables 1& 2 to determine the highest value of "Rated Average Current" for the SM or DSM (across the listed voltage range), then add this value to the total current for any other appliances powered by the same source and include any required safety factors. Refer to Instruction Sheet for addtional information. Table 2. Sync module (DSM) current requirements (AMPS) UL Voltage ULC Voltage Rated Average Current Rated Peal' Current Rated Inrush Current lnl/1n2 Audible In1Iln2 Audible In1Iln2 AudbIe 8.0 VDC 10.5VDC 0.019 0.004 0.055 0.004 0.150 0.0i€• 12.0 VOC 12.0 VDC 0.020 0.004 0054 0.004 0.170 0.019 24.0 VOC 24.0 VDC 0.035 0.008 CIBa 0.008 0.342 0.030 33.0 VDC 33.0 VDC 0.045 0.010 0.050 0.010 0.470 0.040 8.0 VRMS 8.0 VRMS 0.028 0.005 0.137 0.008 0.210 0.016 12.0 VRMS 12.0 VRMS 0.030 0.006 0.103 0.009 0.240 0.019 24.0 VRMS 24.0 VRMS 0.048 0.010 0.145 0.015 0.480 0.033 33.0 VRMS 31.0 VRMS 0.062 0.012 0.175 0.022 0.685 0.056 Table 3. Current consumption DSM modules Output Circuit Description of DSM Module DSM Module Class "B" with Audible Silence (dual circuit( V Class "B" with No Audible Silence (dual circuit) V Class "A" with Audible Silence (single circuit) V Class "A" with No Audible Silence (single circuit) V Notes: 1. DSM dual sync modules are rated for 3.0 amperes per circuit. The maximum number of intercor.nected DSM modules is twenty (20Y. Non-sync appliances can be installed before or after a DSM. If the non-sync apia ice requires audible silence, four wire connection a necessary with the strobe circuit connected before the DSM NAC circuit, an: the audible lea is connected to a silen:eable NAC circuit from the FACP The audible appliance produces a momentary interruption (approx mateli 25ms' each time the strobes flash. Circuit #2 may be omitted if only 1 circuit is required when using me DSM. Non-sync audible appliances can be installed on the audible NAC. Be aware of the current requirement for :be DSM mo:ule. See Table 2. 2 EATON www.eaton.com Wheelock DSM Technical Data TD450081EN Effective October 2016 Table 4. Specifications and Ordering Information Model Number Finish Order Code Input Voltage VDC Average Current @ 12 or 24 VDC UL Max® Mounting Options® LDSM-12/24-R®® Red 6374 12 0.020 0.026 W 24 0.035 0.055 W ® RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range )16-33v for 24v units). For strobes, the UL max current is usually at the minimum listed voltage )16v for 24v units). For audibles, the max current is usually at the maximum listed voltage )33v for 24v units). For unfiltered FWR ratings, see installation instructions. ® Refer to Data Sheet #TD450028EN for mounting options. ® The total distance from the first to the lest DSM shall not exceed 1,000 feet of #18 AWG wire. Use only18 AWG wire. Architects and engineers specifications The sync modules shall be Wheelock DSM sync modules. Wheelock DSM sync modules shall be the master controllers for Wheelock Execeder (HS), Wheelock Exceder LED (LSPST LHS), and Wheelock AH-We MT E, EH, ET70/90/1080, RSS/RSSF and CH70 product lines appliances where a synchronized audible/visual audible or visual only appliance is specified. All modules shall be UL listed under Standard 464. Wheelock DSM modules shall be designed to interface with AS audible strobeappliances and horn strobe appliances to produce a synchronized temporal (Code 3) horn as well as synchronized strobe flash on a two-wire alarm circuit. DSM modules shall provide an additional strobe circuit input/output for control of either two Class "B" NAC circuits or a single Class "A" NAC circuit. Upon activation of the audible silence function at the fire alarm control panel, the audible signal component of AS audible strobes and/or NS horn stobes may be silenced while maintaining strobe activation. When using the low frequency 520 sounder (LFHSK) the DSM shall provide the code three temporal (13) and also the code four temporal (T4) for carbon monoxide signalling. DSM module shall be DSM-12/24 for control of either Class A two (2) Class B NAC circuits. The DSM dual circuit version shall provide the additional capability of "daisy-chaining"—the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. Interconnection capability shall be for a maximum of 40 NAC circuits. All modules shall operate on either 12 or 24 VDC. The DSM 12/24 shall be 0.020 amperes @ 12 VDC and 0.035 amperes @24 VDC. The dual circuit DSM sync module shall be capable of handling a load of 3 amperes per NAC circuit at 12 or 24 VDC. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of #18 to #12 AWG wire size. DSM sync modules shall mount to a 4-11/16" x 2-1/8" deep backbox. Member - WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Note: Due to Continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock, Inc. dba Eaton standard terms and conditions. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eatoncom Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www.eaton.comlmassnotiticatioa @2016 Eaton E All Rights Reserved Printed in SA Publication No. TD450081 EN Powering Business Worldwide October 2016 Eaton is a registered trademark. - All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (300-0785:013'2 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models SM-12/24, SMX-112/24DSM-12/24and DSMX-12/24 Synchronized Control Modules. Models SM-12/24 and DSM-12/24 may be followed by -R, -w, -x or -S. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-33 VDC* INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling appliances accessory for use with separately listed synchronized strobe lights. For indoor use only. Rev. 05-26-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires @une3O,2O1 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use J of a tool and are located behind the appliance to prevent tampering. ~J J Wall models feature voltage test points to take readings with a J voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Exceder Strobe, Horn Strobe, and Horn Notification Appliances FITON Powering Business Worldwide Technical Data TD450049EN Effective November 2016 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover H s--- ---. Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) 2 EATON www.eaton.com HN Series HS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance draw@ 12/24VDC on a single appliance Easy to remember model numbers 0 Patented Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ massnotification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range: All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock Sync Modules or panels with built-in WheelockO Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPNANSI/OSHA RoHS Model Legend HN = Horn A = Red ST = Strobe A = Agent Lettering (strobes only) HS = Horn Strobe AL = Alert Lettering (strobes only) C = Ceiling Mount N = No Lettering (strobes only) W = White Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering Example: HSR tL 'Ill! Example HSWC HN Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC /24 FWR Technical Data TD450049EN Effective November 2016 12 VDC Regulated Voltage Model Range VOC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15175 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 SIC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15175 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0,148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0,136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL man current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VOC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VOC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Regulated Voltage Model Range VOC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Model Strobe Candela Sync WI OSM or Wheelock Power Supplies 12/24 VOC® Mounting Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® HSW 15/1575/30/75/95/110/135/185 X X UMB0 HSRC 15/30/60/75/95/115/150/177 X X UMB® 1HSWC: 15/30/60/75/95/115/150/177 X X UMB® Strobes SIR 15/1575/30/75/95/110/135/185 X X UM8® SIW 15/1575/30/75/95/110/135/185 X X UMB® STAC 15/30/60/75/95/115/150/177 X X UMB® 1WC 15/30/60/75/95/115/150/177 X X UMB® Horn HNR X X UMB® HNW X X UMB® HNRC X X UMB® HNWC X X UMB® ® 12 VOC models feature 15 & 15/75 settings ® UMB = Universal Mounting Base EATON www.eaton.com 3 Technical Data TD450049EN HN Serieê Effective November 2016 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged LexanO lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's OSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/massnotification @2016 Eaton _N All Rights Reserved I Printed in USA L Publication No. TD450049EN Powering Business Worldwide November 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:016'8 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: ModelsST,strobe, HS' horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) orW(white). Additionally, a may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm r ° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division