Loading...
HomeMy WebLinkAbout2265 CAMINO VIDA ROBLE; ; AS150353; Permit10/29/2020 AS150353 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS150353 2265 CAMINO VIDA Job Address: ROBLE Permit Type: SPRINK Parcel No: 2130502400 Lot #: 0 Status: APPROVED Applied 12/3/2015 Approved: 12/3/2015 Reference No.: Issued: 12/3/2015 PC #: Inspector: Project Title: THE FIELDS CHURCH NEW WET SPRINKLER SYSTEM Applicant: TITAN FIRE PROTECTION 2880 SCOTT ST VISTA, CA 92081 760-295-3436 Owner: RB CO R E L P P0 BOX 1780 LA MESA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 284 0 284 0 1/1 HYDRAULIC CALCULATIONS FOR THE FIELDS CHURCH 2265 CAMINO VIDA ROBLE CARLSBAD, CA. 92011 DRAWING NUMBER: FS-3 DATE: 11/6/15 ME COPY -DESIGN DATA- REMOTE AREA NUMBER: #1 REMOTE AREA LOCATION: FOYER OCCUPANCY CLASSIFICATION: LIGHT HAZARD DENSITY: .10 gpm/sq. ft. AREA OF APPLICATION: 1500 sq. ft. COVERAGE PER SPRINKLER: 168 MAX. TYPE OF SPRINKLERS CALCULATED: 5.6 UPRIGHT NUMBER OF SPRINKLERS CALCULATED: 10 HOSE-STREAM DEMAND: 100 gpm TOTAL WATER REQUIRED (INCLUDING HOSE) : 275.7 gpm FLOW AND PRESSURE (AT BASE OF RISER): 175.7 gpm 8 44.7 psi * TYPE OF SYSTEM: WET / GRID - WATER SUPPLY Source: CARLSBAD PIRE Test Date: 11/12 5 Test By: J. MAEL Lo ation: SITE HYDRANT ic: 135 psi Residual: 119 psi Flow: 55.5 gpm orce Elevation Relative to Finished FlpoP Level: +3 ft. INSTALLING CONTRACTOR Name: TITAN FIRE Address: 2880 SCOTT ST. #105, VIS CA. 92081 Phone: 760-295-3436 Certification n1mber: Cl6-989280 NAME OF DESIGNER: NICK DEGEORGE (DC DESIGN 619-248-1732) AUTHORITY HAVING JURISDICTION: CITY. OF CARLSBAD NOTES: Calculations performed by HASS urder license -k. 50111768 granted by HRS SYSTEMS, INC. (Notes continue after pipe calculation (Notes continue after pipe calculations results 4, kS150353 FILE COPY SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/6/2015ESIGN\DG DESIGN CALCS\HRS SYSTEMS\HASS85\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH WATER SUPPLY ANALYSIS Static: 121.50 psi Rend: 107.00 psi Flow: 5325.0 gpm 140.0 LEGEND 112.0 G A U G E 84.0 P R E S S 56.0 U R 2 E 1 •Available pressure 121.44 psi @ 275.7 gpm 2 •Required pressure 50.14 psi 8 275.7 gpm Source Supply Curve System Demand Curve p 28.0 i 0.0 - - - 12018002400 3000 3600 4200 4800 5400 6000 FLOW (GPM) (Note: Dashed Lines indicate extrapolated values from Test Results) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/6/2015ESIGN\DG DESIGN CALCS\HRS SYSTEMS\HASSBS\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 121.5 107.0 5325.0 121.4 275.7 50.1 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 275.7 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 100.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 175.7 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (PT) (PSI) (GPM) 1 15.5 - - - - 10.0 - - - 2 16.0 K= 5.60 9.0 16.8 3 16.0 K= 5.60 9.0 16.8 4 16.0 K= 5.60 9.2 16.9 5 16.0 K= 5.60 9.9 17.6 6 15.5 - - - - 16.0 - - 7 15.5 - - - - 10.0 - - - 8 16.0 K= 5.60 9.1 16.9 9 16.0 K= 5.60 9.1 16.9 10 16.0 K= 5.60 9.2 17.0 11 16.0 K= 5.60 10.0 17.7 12 15.5 - - - - 16.2 - - - 13 15.5 - - - - 11.9 - - - 13A 15.0 - - - - 10.4 - - - 14 15.5 K= 5.60 12.0 19.4 15 15.5 K= 5.60 12.4 19.7 16 15.0 - - - 17.3 - - - 17 15.0 - - - - 24.6 - - - 18 15.0 - - - 19.1 - - - 19 15.0 - - - - 24.8 - - - 20 14.5 - - - - 20.5 - - - 21 14.5 - - - - 25.3 - - - 22 14.5 - - - - 21.4 - - - 23 14.5 - - - - 25.9 - - 24 14.0 - - - - 22.3 - - - 25 14.0 - - - - 26.8 - - - 26 14.0 - - - - 22.7 - - - 27 14.0 - - - - 27.9 - - - 28 13.5 - - - - 23.1 - - - 29 13.5 - - - - 29.5 - - - 29A 13.5 - - - - 24.6 - - - 30 13.5 - - - - 23.2 - - - 31 13.0 - - - - 31.8 - - - 32 13.0 - - - - 23.4 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/6/2015E51GN\DG DESIGN CALCS\HRS SYSTEMS\HASS85\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (PT) (PSI) (GPM) TOR 13.0 - - - - 38.3 - - - BOR 0.5 - - - - 44.7 - - - BF1 3.0 - - - - 44.2 - - - BF2 3.0 - - - - 49.2 - - - UG1 -3.0 - - - - 52.4 - - - Fl-i -3.0 HOSE STREAM 52.4 100.0 SOURCE 3.0 SOURCE 50.1 275.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 11/6/2015ESIGN\DG DESIGN CALCS\HRS SYSTEMS\HASS85\FIELDS CFIDRCH.SDF JOB TITLE: FIELDS CHURCH NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 5.60 16.8 Disch 9.00 120 1.0 1 15.5 10.0 3.9 3 1.250 2T:16.0 16.00 -0.2 2 16.0 9.0 20.7 1.442 25.00 0.029 0.7 Pipe: 2 5.60 16.8 Disch 11.00 120 0.0 2 16.0 9.0 -12.9 4 1.250 ---- 0.00 0.0 3 16.0 9.0 3.9 1.442 11.00 0.001 0.0 Pipe: 3 5.60 16.8 Disch 13.00 120 0.2 4 16.0 9.2 -3.9 2 1.250 ----- 0.00 0.0 3 16.0 9.0 12.9 1.442 13.00 0.012 0.2 Pipe: 4 5.60 16.9 Disch 13.00 120 0.8 5 16.0 9.9 12.9 3 1.250 ---- 0.00 0.0 4 16.0 9.2 29.9 1.442 13.00 0.058 0.8 Pipe: 5 5.60 17.6 Disch 27.00 120 6.1 6 15.5 16.0 29.9 4 1.250 2T:16.0 16.00 -0.2 5 16.0 9.9 47.5 1.442 43.00 0.137 5.9 Pipe: 6 5.60 16.9 Disch 9.00 120 0.9 7 15.5 10.0 3.6 9 1.250 21:16.0 16.00 -0.2 8 16.0 9.1 20.4 1.442 25.00 0.029 0.7 Pipe: 7 5.60 16.9 Disch 11.00 120 0.0 8 16.0 9.1 -13.3 10 1.250 ---- 0.00 0.0 9 16.0 9.1 3.6 1.442 11.00 0.001 0.0 Pipe: 8 5.60 16.9 Disch 13.00 120 0.2 10 16.0 9.2 -3.6 8 1.250 ---- 0.00 0.0 9 16.0 9.1 13.3 1.442 13.00 0.013 0.2 Pipe: 9 5.60 17.0 Disch 13.00 120 0.8 11 16.0 10.0 13.3 9 1.250 ---- 0.00 0.0 10 16.0 9.2 30.3 1.442 13.00 0.060 0.8 Pipe: 10 5.60 17.7 Disch 27.00 120 6.2 12 15.5 16.2 30.3 10 1.250 2T:16.0 16.00 -0.2 11 16.0 10.0 48.0 1.442 43.00 0.140 6.0 Pipe: 11 0.0 0.0 0.50 120 1.5 13 15.5 11.9 41.2 7 1.250 2T:16.0 16.00 0.2 13A 15.0 10.4 41.2 1.442 16.50 0.105 1.7 Pipe: 12 0.0 41.2 13A 33.00 120 0.0 14 15.5 12.0 -38.2 17 1.250 ---- 0.00 0.0 13 15.5 11.9 2.9 1.442 33.00 0.001 0.0 Notes SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 11/6/2015ES1GN\DG DESIGN CALCS\HRS SYSTEMS\HASS85\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 13 5.60 19.4 Disch 13.00 120 0.4 15 15.5 12.4 2.9 13 1.250 ---- 0.00 0.0 14 15.5 12.0 22.3 1.442 13.00 0.034 0.4 Pipe: 14 5.60 19.7 Disch 27.00 120 4.9 16 15.0 17.3 22.3 14 1.250 2T:16.0 16.00 -0.2 15 15.5 12.4 42.0 1.442 43.00 0.109 4.7 Pipe: 15 0.0 41.2 13A 120.50 120 12.7 17 15.0 24.6 -2.9 14 1.250 2T:16.0 16.00 -0.2 13 15.5 11.9 38.2 1.442 136.50 0.091 12.5 Pipe: 16 0.0 137.5 16 193.00 120 5.7 19 15.0 24.8 -118.4 20 1.250 4T:32.0 32.00 0.0 18 15.0 19.1 19.1 1.442 225.00 0.025 5.7 Pipe: 17 0.0 118.4 18 193.00 120 4.9 21 14.5 25.3 -100.9 22 1.250 41':32.0 32.00 0.0 20 14.5 20.5 17.5 1.442 225.00 0.022 4.9 Pipe: 18 0.0 100.9 20 193.00 120 4.5 23 14.5 25.9 -84.2 24 1.250 4T:32.0 32.00 0.0 22 14.5 21.4 16.7 1.442 225.00 0.020 4.5 Pipe: 19 0.0 84.2 22 193.00 120 4.6 25 14.0 26.8 -67.2 26 1.250 4T:32.0 32.00 0.0 24 14.0 22.3 17.0 1.442 225.00 0.020 4.6 Pipe: 20 0.0 67.2 24 193.00 120 5.2 27 14.0 27.9 -49.1 28 1.250 4T:32.0 32.00 0.0 26 14.0 22.7 18.2 1.442 225.00 0.023 5.2 Pipe: 21 0.0 12.7 30 98.00 120 5.0 29 13.5 29.5 13.0 28 1.250 2T:16.0 16.00 0.0 29A 13.5 24.6 25.6 1.442 114.00 0.044 5.0 Pipe: 22 0.0 49.1 26 100.00 120 1.5 29A 13.5 24.6 -36.1 30 1.250 E: 4.0 20.00 0.0 28 13.5 23.1 13.0 1.442 2T:16.0 120.00 0.012 1.5 Pipe: 23 0.0 36.1 28 98.00 120 1.4 29A 13.5 24.6 -23.4 32 1.250 E: 4.0 20.00 0.0 30 13.5 23.2 12.7 1.442 2T:16.0 118.00 0.012 1.4 Pipe: 24 0.0 0.0 193.00 120 8.3 31 13.0 31.8 23.4 30 1.250 4T:32.0 32,00 0.0 32 13.0 23.4 23.4 1.442 225.00 0.037 8.3 Pipe: 25 0.0 0.0 12.00 120 0.0 7 15.5 10.0 20.7 2 2.000 ---- 0.00 0.0 1 15.5 10.0 20.7 2.157 12.00 0.004 0.0 Notes SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 11/6/2015ESIGN\DG DESIGN CALCS\HRS SISTEMS\HASS85\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pfi'ft. (Pt) Pipe: 26 0.0 20.7 1 12.00 120 0.4 13A 15.0 10.4 20.4 8 2.000 ---- 0.00 -0.2 7 15.5 10.0 41.2 2.157 12.00 0.015 0.2 Pipe: 27 0.0 0.0 12.00 120 0.2 12 15.5 16.2 47.5 5 2.000 ---- 0.00 0.0 6 15.5 16.0 47.5 2.157 12.00 0.019 0.2 Pipe: 28 0.0 47.5 6 12.00 120 1.1 16 15.0 17.3 48.0 11 2.000 ---- 0.00 -0.2 12 15.5 16.2 95.5 2.157 12.00 0.070 0.8 Pipe: 29 0.0 95.5 12 13.00 120 1.8 18 15.0 19.1 42.0 15 2.000 ---- 0.00 0.0 16 15.0 17.3 137.5 2.157 13.00 0.138 1.8 Pipe: 30 0.0 137.5 16 11.00 120 1.4 20 14.5 20.5 -19.1 19 2.000 ---- 0.00 -0.2 18 15.0 19.1 118.4 2.157 11.00 0.104 1.1 Pipe: 31 0.0 118.4 18 12.00 120 0.9 22 14.5 21.4 -17.5 21 2.000 ---- 0.00 0.0 20 14.5 20.5 100.9 2.157 12.00 0.078 0.9 Pipe: 32 0.0 100.9 20 12.00 120 0.9 24 14.0 22.3 -16.7 23 2.000 ----- 0.00 -0.2 22 14.5 21.4 84.2 2.157 12.00 0.056 0.7 Pipe: 33 0.0 84.2 22 12.00 120 0.4 26 14.0 22.7 -17.0 25 2.000 ---- 0.00 0.0 24 14.0 22.3 67.2 2.157 12.00 0.037 0.4 Pipe: 34 0.0 67.2 24 7.00 120 0.4 28 13.5 23.1 -18.2 27 2.000 ---- 0.00 -0.2 26 14.0 22.7 49.1 2.157 7.00 0.020 0.1 Pipe: 35 0.0 49.1 26 8.00 120 0.1 30 13.5 23.2 -13.0 29A 2.000 ----- 0.00 0.0 28 13.5 23.1 36.1 2.157 8.00 0.012 0.1 Pipe: 36 0.0 36.1 28 9.00 120 0.3 32 13.0 23.4 -12.7 29A 2.000 ---- 0.00 -0.2 30 13.5 23.2 23.4 2.157 9.00 0.005 0.0 Pipe: 37 0.0 0.0 13.00 120 0.2 19 15.0 24.8 38.2 13 2.000 ---- 0.00 0.0 17 15.0 24.6 38.2 2.157 13.00 0.013 0.2 Pipe: 38 0.0 38.2 17 11.00 120 0.5 21 14.5 25.3 19.1 18 2.000 ---- 0.00 -0.2 19 15.0 24.8 57.3 2.157 11.00 0.027 0.3 Notes SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 11/6/2015E51GN\DG DESIGN CALCS\HRS SYSTEMS\HASS85\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 39 0.0 57.3 19 12.00 120 0.5 23 14.5 25.9 17.5 20 2.000 ---- 0.00 0.0 21 14.5 25.3 74.8 2.157 12.00 0.045 0.5 Pipe: 40 0.0 74.8 21 12.00 120 1.0 25 14.0 26.8 16.7 22 2.000 ---- 0.00 -0.2 23 14.5 25.9 91.6 2.157 12.00 0.065 0.8 Pipe: 41 0.0 91.6 23 12.00 120 1.1 27 14.0 27.9 17.0 24 2.000 ---- 0.00 0.0 25 14.0 26.8 108.5 2.157 12.00 0.089 1.1 Pipe: 42 0.0 108.5 25 12.00 120 1.6 29 13.5 29.5 18.2 26 2.000 ---- 0.00 -0.2 27 14.0 27.9 126.7 2.157 12.00 0.118 1.4 Pipe: 43 0.0 126.7 27 12.00 120 2.2 31 13.0 31.8 25.6 29A 2.000 ---- 0.00 -0.2 29 13.5 29.5 152.3 2.157 12.00 0.166 2,0 Pipe: 44 0.0 152.3 29 12.00 120 6.5 TOR 13.0 38.3 23.4 32 2.000 3E:18.0 18.00 0.0 31 13.0 31.8 175.8 2.157 30.00 0.217 6.5 Pipe: 45 0.0 0.0 12.50 120 6.4 BOR 0.5 44.7 175.8 31 2.500 ---- 0.00 -5.4 TOR 13.0 38.3 175.8 2.635 12.50 0.082 1.0 Pipe: 46 0.0 0.0 39.00 150 0.5 BF1 3.0 44.2 175.8 TOR 4.000 2E:40.0 79.00 1.1 BOR 0.5 44.7 175.8 4.240 T:39.0 118.00 0.005 0.6 Pipe: 47 0.0 Fixed Pressure Loss Device BF2 3.0 49.2 175.8 BOR 5.0 psi, 175.8 gpm BF1 3.0 44.2 175.8 Pipe: 48 0.0 0.0 2E:40.0 21.00 150 3,2 UG1 -3.0 52.4 175.8 BFI 4.000 T:39.0 83.00 -2.6 BF2 3.0 49.2 175.8 4.240 G: 4.0 104.00 0.005 0.6 Pipe: 49 0.0 0.0 20,00 150 0.0 Fl-I -3.0 52.4 175.8 BF2 6.000 ---- 0.00 0.0 UG1 -3.0 52.4 175.8 6.080 20.00 0.001 0.0 Pipe: 50 Source 100.0 Disch E:22.0 80.00 150 2.3 SOURCE 3.0 50.1 175.8 UG1 6.000 T:46.0 73.00 2.6 FF1 -3.0 52.4 275.7 6.080 G: 5.0 153.00 0.002 0.3 Notes U SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 11/6/2015ESIGN\DG DESIGN CALCS\HRS SYSTEMS\HASS85\FIELDS CHURCH.SDF JOB TITLE: FIELDS CHURCH NOTES (HASS) (1) Calculations were performed by the HASS 8.5 computer program under license no. 50111768 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.151 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 15.4 ft/sec at pipe 44. (4) a. System remote area HAS been proven or 'peaked' Minimum pressure at any sprinkler: 9.001 psi Minimum pressure with remote area shifted one sprinkler space toward right cross main: 9.280 psi Remote area is located adjacent to left cross main (5) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (6) Available pressure at source node SOURCE under full flow conditions is 121.38 psi compared to the minimum required pressure of 20.00 psi. (7) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.442 4.00 8.00 3.00 9.00 8.00 1.00 12.00 12.00 8.00 2.157 6.00 12.00 3.00 14.00 8.00 1.00 12.00 12.00 12.00 2.635 8.00 17.00 6.00 19.00 10.00 1.00 14.00 14.00 17.00 Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP c®Los Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 ASIS0353 <E> APPROVED Fig. 35E3-90° Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35FRE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 INK Fig. 35F3 -45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 SQ 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 351 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsrnithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1x1/2 35R13010004 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1x 3/4 x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x 1/2x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 i-1/4 x3/4 x1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35R13012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1 x 11 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x 1 x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1l4x1x1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4xlx1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 i-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35R13014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35R13014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-112 x lxi 1/4 35R13014010012 182 167 188 12 24 12 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 i-1/2x1-1/4 x 1/2 35R13014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4 x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x 1-1/4x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2x 1 x2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-i/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x 1-1/2 35R13020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-i/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 C&US <~> APPROVED Fig. 35RT3 - Reducing Tee LISTED tII Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in - Packing Weight lb Inner Master 3/4x 1 358T3006010 1.45 1.45 1.37 30 60 0.6 1x1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1x1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4xlxi-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35B13012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35B13014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.corn 112 APPROVED Fig. 3503 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 350P3012 2.00 35 70 0.5 1-1/2 35C 3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1,38 40 80 0.6 2x1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug in I Size I Part Number A in Packing Weight lb Inner Master I 1/2 35SP3004 0.94 600 1200 0.07 35SP3006 1.12 350 700 0.1 I_1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master, 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x314 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) I 35RC3020010 2.81 20 40 1 1.0 Fig. 35HB3 - Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number ____ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 1 3.12 1 6 12 1 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Size in Part Number A in Packing Weight lb Inner Master 1/2 35C3004 0.87 300 600 0.1 3/4 35C3006 0.97 200 400 0.1 1 35C3010 1.16 110 220 0.2 1-1/4 35C3012 1.28 70 140 0.4 1-1/2 35C3014 1.33 50 100 0.5 2 35C3020 1.45 25 50 0.8 2-1/2 35C3024 1.70 18 36 1.6 Fig. 358C3 - Beam Clamp C(DUI APPROVED A A Fig. 35X 3- Cross LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X3020 2.25 6 12 2.8 Fig. 35RX3 - Reducing Cross I Size I in I I Part Number I I ' A I in I B I Iin I Packing I I Weight I I I I lb I r I 1-1/4x1 I 35RX3012010 I 1.67 1.58 I 15 1.2 /2 x135RX3014010 Inne t30 351RX3020010 1.80I1.6512 1.4 2x 1 2.02 _1.73 _8 2.0 Fig. 35C 3- Cap Size in Part Number ______ A in Packing Weight lb Inner Master 3/8 35BC3003 0.75 100 200 1 0.3 1/2 353C3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 STYLE 005H WITH VICPLUSTM GASKET SYSTEM FireLock Style 005H rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design Aj"T"T" permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005H FireLock coupling are designed and recommended for use ONLY on fire vicplut protection systems. 1Gas.et System Vic.PlusTM Gasket System: Victaulic offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-Plus System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. Exaggerated for clarity LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. FM approved for service in 1 ½ - 4' pipe. UL Listed for service up to 4 pipe only. @ UL Listed for service up to 3 only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Approved Date www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. at 2013 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_K 4tauiicr 10.02_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE OO5H WITH VICPLUSTM GASKET SYSTEM Size Actual Nominal Size Diameter Outside Inches mmi 32 42.4 2413 3370 1.2 70 114 48 1 0.5 4. .4. -. .. - -. 11/2 1,900 350 990 0.05 3 1 - rtl 3.00 4.75 1.88 1.2 40 48.3 2413 I 4415 1.2 76 121 48 0.5 4-.. -I-.- -- -- + - 2 2.375 350 1550 I 0.07 2- /r x 2,5 3.50 5.25 1.88 I 1.6 50 4- 21/2 60.3 -- 2.875 2413 350 --4-----t------ 6900 2270 I 1.7 I 89 ' 133 48 -.-.+---- - 0.7 -- 65 73.0 2413 10110 0.07 1.7 - 3/ I 4.00 102 5.75 I 1.88 146 I 48 1.9 .09 4. 76.1 mm 3.000 350 2475 0.07 2- /8x 2/2 4.13 5.75 I 1.88 1.9 I 76.1 2413 ---I 11010 1.7 105 - 146 48 ----I- 0.9 3 3.500 350 ' 3365 I 0.07 2- /r X 2/2 4.63 6.13 1.88 2.1 80 88.9 2413 14985,_. 1.7 118 ' 156 48 1.0 4 4.500 350 5565 0.16 2-,'852,'2 5.75 7.25 2,13 3.1 100 114.3 2413 24770 4.1 146 184 54 1.4 ---+----- 1080mm 4.250 ,,---_--- 300 ____- 4255 ____ 0.16 ____ 2 - 3/a s 2 1/2 -_-- 5,63 -.---.-_-,.t----- 7.25 2.13 - 3.1 108.0 2068418940 4 143 18454 -- 1.4 0.16 1 2-/2x3 6.88 5 5.563 300 7290 9.00 2.13 4.5 125 I- 141.3 - 2068 32445 I 4.1 -- 175 - 229 . 54 - -I------ 2.0 - - 133.0mm 5.250 300 6495 0.16 2-/2 x 2 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 .4J 168 229 . 54 2.0 5.500 300 7125 t 0.16 6.88 139.7 mat TOO 23 4.8 I- 139.7 2068 31715 4.1 I 175 229 ' 54 - -----. 2.2 .- -. -I- ------•- ' -+ -.- 6 6.625 300 10340 1 0.16 - 1 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 . 203 254 . 53 2.3 1 6.250 ---------.. 300 -----i---------+--------- 9200 -------1----- 159.0 mm 0.16 2- ½ x 2' 7.63 10.00 2.13 5.5 159.0 2068 40955 4.1 194 254 , 54 I 2.5 ... ---4- .-..-- -- - -,--------f-- .15-t -+ 165.1 mm 6.500 300 9955 0.16 2-/2 3 10.00 2.13 I 5.5 165.1 2068 44295 4.1 I --- .-----..... 207 254 54 I 2.5 8 8.625 .....--I 300 17525 - 0.19 2 - 5/s x41/4 10.50 t--.---.-t.-, - 13.14 2.63 11.3 200 . 219.1 2068 78000 4.8 267 334 67 5.1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure maybe increased to 1½ times the figures shown. The allowable pipe separation dimension shown is for system layout purposes only. Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. Style 005F1 couplings are VdS and LPC Approved to 1613ar/235 psi. DIMENSIONS - i•L JUL JUL - m Eilv] Rated for wet and dry sprinkler systems at 350p5i/2413 kPa fort ¼ - 4732 - 100mm sizes and 300 psi /2068kPa for 41/4 - 87108 - 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005H is rigid and does not accommodate expansion, contraction or angular deflection. www.victaulic.com Ai-c-ta-uhd VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.02_2 REV_K IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE OO5H WITH VICPLUSTM GASKET SYSTEM MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E' EPDM - Type A Vic-Plus Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade 'E" Type A Vic-Plus° Gasket System, requiring no field lubrication for most installation conditions. Grade L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade 'E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com ,4'tauiic vicTAuLic IS REGISTERED TRADEMARK OF VICTAILLIC COMPANY. © 2013 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. REV_K 10.02_3 STYLE 005H WITH VIC-PLUSTM GASKET SYSTEM GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. For complete contact information, visit www.victaulic.com 10.02 1538 REV K UPDATED 0212013 It.Ac--ta -U1 ii d vICTAuLIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2013 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. 10.02 STYLE 75 Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "I" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference document 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to document 17.01. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. Optional: Hot dipped galvanized and others. Gasket: (specify choice*) Grade E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/-t-30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. NOTE: Additional gasket styles are available. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com vIcTAuLIc IS REGISTERED TRADEMARK OF vICrAuLIC COMPANY. © 2013 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_N \4tauhcr 06.05_i CARBON STEEL PIPE - GROOVED COUPLINGS 0605 Flexible Coupling STYLE 75 DIMENSIONS Max. W rk Allow. Pipe Bolt/Nut@ Approx. Size Pressure * Max. End Load End Sep. t Deflect. Fr. CLt No - Size Dimensions - Inches/mm Wgt.Each Actual Nominal Outside Size Diameter Per. Pipe Inches Inches psi Lbs. Inches Cplg. In./Ft. Lls. 1 1.315 500 680 0-0.06 0.57 2.38 427 1.77 1,3 25 33.4 3450 3025 0-16F2*43 48 2- /8 x 2 61 108 45 0.6 14 1.660 500 1080 ' 0-0.06 10 0,45 ' 2 3/ 2 2.68 4.61 1,77 1.4 32 422 , 3450 4805 0-1.6 - 38 ,, 8X 68 1174 45 0.6 1 ½ 1.900 500 1420 0-0.06 0.40 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 1 -56 33 2 -3/s x 2 74 122 45 0.6 -- 500 2 2.375 500 2215 0-0.06 1 -31' 0.32 2 _3/ x 2 3,43 5.22 1.88 1.7 50 60.3 3450 1 9860 1 0-1.6 26 87 133 48 0.8 21/2 t' 2.875 500 3245 0-0.06 -is' 0.26 2 _3/ x 2 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1,6 22 98 144 48 , 0.9 3.000 500 3535 0-0.06 , 0.26 4.00 5.90 1.88 1.9 76.1 mm 76.1 3450 15730 0-1.6 1*- 12 22 2- /s52 102 150 48 0.9 3 1 3.500 500 4800 0-0.06 V -2' 0.22 2 - 1/2 x 20' 4.50 7.00 i 1,88 2.9 88.9 3450 21360 .0-1.6 18 114 178 48 1.3 3½ 4.000 500 6300 0-0.06 . 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0 -54 16 2-i5x2A 127 191 48 1.3 4 4.500 500 7950 0-0 * 13 , 0.34 5.80 8.03 2.13 4.1 100 1 114.3 3450 35380 0-3..2 1 -36 28 I 2-/2x24147 204 54 1.9 - .. -- - - - --_ . - - 4.250 450 6380 0-0.13 V 41' 0,35 I 2 12 700 sss 7.79 2.13 3.7 108.0 mm , 300 , 28395 .1 0-I? , - - ' 141 198 54 1.7 - 41/2 t 5.000 450 8820 0-0.13 1 -26' 0.25 2-/ x 30' 6.13 9.43 2.13 , 5.5 120 127.0 3100 f 39250 0- 3.2 21 156 240 54 . 2.5 . ..------- ---H- 5 5.563 450 10935 0-0.13 1'-18' 0.27 2 _5/ x 30' 6.88 10.07 2.13 5.8 125 141.3 3100 48660 _0-_3.2 _ - __2 3____ 23 . 175 256 54 2.6 -----+.--- .----l---- 'I--- -------- ---+._. - ------.--.. -+-------- 5250 450 9735 I 0-0.13 V 21' 0.28 2 16 825 6.55 9.37 2.13 ' 6.0 . mm 133.0 3100 43325 0-3.2 - 24 . - X . 166 238 ' 54 2.7 5500 450 1' 10665 I 0-0.13 0.28 6.80 9.59 't 2j-1 63 139,7 mm 139.7 3100 47460 0- 3.2 1'-18' 2- 24 /8 x ' 173 244 54 2.9 -,-----.-.+--------- 'l--- --- ______ 6.000 450 12735 0-0.13 , 0.21 7.38 10.48 1.88 62 152.4mm 152.4 3100 56670 0-3.2 187 266 48_2B 6 6.625 450 15525 0-0.13 , 0.23 8.00 11.07 2.13 . 7.0 150 168.3 3100 i 69085 0- 3.2 1 5 18 2- /s x 203 281 54 ' 3.2 ---r------l--'----- 1 6.250 450 I 13800 0-0.13 , 0.24 7.63 10.49 2.13 6.8 159.0mm 159.0 3100 61405 I 0-3.2 9 20 2-16x82.5 194 266 1 54 3.1 I---- -. -___ ..-----. +-..-.-..---_-- - - '---------------H----f .. 8 8.625 450 26280 0-0.13 o 50' 0.18 ' 2 0' 40' . 10.34 13.97 ' 2.32 12.4 200 219.1 3100 , 116945 0-3.2 - 14 j - 263 355 59 I 5.6 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled, These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 -31/2720 -90 mm; 25% for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. Igo vy, -owl I ru www.victautic.com VIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 06.05_2 \4taulicr REV_N STYLE 75 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. For complete contact information, visit www.victaulic.com 06.05 1470 REV N UPDATED 01/2013 ictauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.05 FireLock® FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock EZ® Style 009N/Style 009H couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Red Enamel in EMEA-l. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR l[1IIii; System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com VicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K Jtauhcr 10.03_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 Fire Lock® Fittings DIMENSIONS CtoE.1 C C to NO. 001 NO. 003 NO. 002 NO. 006 Size 90'.Elbow 45* Elbow Straight '• No inal Actual prox."", Inches Lbs. inches Lbs. Inches Lbs. Inches Lbs.- 32 42A 21 03 1½ • 1.900 - - - - - - t 0.82 0.4 49 L 48.3 - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 t 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 I 22 0.3 - - .--,---. ..-. .1-'--- - - 2½ 2.875 3.00 3.1 2.25 2.2 3.00 3.6 I 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 '1 2,25 2.4 76,1 mm 76.1 76 1.5 57 1.1 - -I---. - - 3 . 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 j 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108mm 108.0 102 j 2.6 76 23 102 3.4 J - 4 , 4.500 4.00 I 6,7 1 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 j 3.0 76 2,5 102 3.9 25 1.1 5 : 5.563 4.88 12.6 3.25 8.3 4.88 '71" 1.00 4.1 125 , 141.3 124 J 5.7 . 83 3.8 124 ,J 7.1 25 1.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 159mm 158.8 140 5.7 ' 89 4.2 140 1 8.0 - - 6 6,625 5.50 18.3 T" 11.7 5.50 22.7 1.00 _25- 5.9 150 168.3 140 8.3 I 89 5.3 140 10.3 2,7 ....,.-..... t - 8 8.625 6.81 25.5 4.25 20.4 6,94 38.7 1.13- 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 www.victaulic.com 14tauiic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03_2 REVK IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com JtauIic.° VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K 10.03_3 GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.03 1539 REV K UPDATED 09/2012 ictauhc VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 A JD ITAtf FIRE PROTECTION 5) Valves 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com FireLock® Ball Valve DIMENSIONS 1½ and 2/40 and 50mm sizes feature a ½'/12mm tap (Groove by Groove only). SERIES 728 The Series 728 FireLock valve is a full port, ball valve that is ULIFM rated for 365psi/25 BAR service in all sizes (LPCB and VdS listed for 20 BAR services). Available with grooved or threaded ends (NPT), the valve body is brass. The ball is chrome plated brass with a stainless steel stem. Reinforced seats aid ease of operation and provide a durable, corrosion-free seat. Flow characteristics exceed UL Specification 1091 and FM Approval Standard 1112. The valve is approved for indoor and outdoor use. PERFORMANCE 1/25 Thread K Thread 0.5 1 1A/32 Groove K Groove 0.7 1 1/4/32 Thread X Thread 1.0 116/40 Groove X Groove 0.2 11/2/40 Thread X Thread 1.0 2/50 Groove X Groove 0.7 2/50 Thread XThread 10 JOB/OWNER CONTRACTOR ENGINEER System No. - Submitted By - Spec Sect - Para Location Date Approved - Date www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF vIcTAuLIC COMPANY. © 2011 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_H \,htaulicr 10.17_i IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.17 FireLock® Ball Valve SERIES 728 SWITCH AND WIRING 1. The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 12501250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @250 VDC Switches supervise the valve in the "OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = 51 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Si Normally Closed: (2) Blue Common: (2) Yellow S2 f Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe 'SlED FINE ALARM CONTROL PANEL SUPERVISORY CONDUIT CIRCUIT ½NFT TWITCRI CONTACT RATING: 10A AT 125 AND 25Db/AC CONDUTCONNECT 0.5AAT 1TDSUTZSDADC 25/Itt 14 IRON NUTS VOLTAGE SOURCE TO END-OF-LINE RESISTOR. OR RE EU T IN MC ATOR N.C. I NO. CON NwI,ch 1:2 leads pe, Ie,,DInaI Sw111N2:l Ieadpe,le,mlnal NOTE: The above diagram shows a connection between the common terminal (yellow — Si and yellow- with-orange stripe —S2) and the normally closed terminal (blue — Si and blue-with-orange stripe —S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). MATERIAL SPECIFICATIONS Valve Body: Brass ASTM B124 Ball: Chrome Plated Brass Ball Valve Stem: 316 Stainless Steel Seat: Carbon Filled (TFE) tetrafluoroethylene Stem Nut: Brass ASTM B-16 C36000 Actuator: Brass traveling nut, on a steel lead screw, in a ductile iron housing www.victaulic.com JtauIie vICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. 10.17_2 REV _H SERIES 728 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.17 2226 REV H UPDATED 05/2011 Aulidta vicTAuLic IS REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.17 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR The Series 705W butterfly valve features an approved weatherproof actuator housing approved for indoor or outdoor use. It has a ductile iron body and disc with EPDM disc coating. The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements. Designed for fire protection services only. Series 705W valve is UL Listed and FM Approved for 300p5i/2065kPa service. The Series 705W is also LPCB approved for 20 Bar and VdS approved for 16 Bar service. Contact Victaulic for details of agency approvals. WEATHERPROOF ACTUATOR Pre-wired supervisory switches that monitor the valve in the fully open position for all sizes. OPTIONAL SUPPLY-SIDE TAP Series 705W valves are available with a ½ NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves. See separate drawings below. This is an optional feature and must be clearly noted on all orders. MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, coated with polyphenylene sulfide blend. Disc: Ductile iron conforming to ASTM A-536, various grades, EPDM coated. Disc Coating: Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Stem Bearings: Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts: Type 416 Stainless Steel. Tap Plug: Carbon steel, plated. 0-Ring: EPDM Bracket: Carbon steel, painted. Actuator: 2112 - 8/65 - 200mm: Bronze traveling nut on a steel lead screw, in a ductile iron housing. 10— 12/250 - 300mm: Steel worm and cast iron quadrant gear, in a cast iron housing. JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2008 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_H 4tauIic° 10.181 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR DIMENSIONS- c®US <S> ILPCBI Size USTED jim,rioic.,o.pim,!iflIItmflw.. Each Nominal Size 2,5 65 Actual Outsid 2.875 732 3.77 95.6 3.77 8.76 225[ 8.76 4.21 1069 4.21 6.08 154.4 6.08 3.00 762 3.00 0.00 0.00 ao*3.8 0.75 0.75 8.3 8.3 76 1 3.000 76.1 3.500 95.6 3.77 222.5 9.40 - 0.08 106.9 4.21 154.4 6.08 76.2 3.00 9.0 0.00* 19.1 0.75 3.8 8.9 3 80 88.9 95.6 4.63 I 238.8 10.84 2.0 0.07 106.9 6.01 ' 154.4 6.98 76.2 I 3.00 0.0 0.73 19.1 1.13 4.0 14.9 4 4.500 100 U43 5.500 5.88 273 12.38 1 I 0.43 152.7 6.01 177.3 8.57 - 762 4.50 18.5 28.7 6 21.0 1397 mm 139.7 5.563 149.4 5.88 , 314.5 12.38 10.9 0.43 152.7 6.01 j 217.7 8.57 114.3 I 4.50 - - 9.5 21.0 5 125 141.3 149.4 5.88 I 314.5 13.41 10.9 1.00 152.7 7.51 I 217.7 9.32 4 114.3 I 4.50 ,j - 1.60 1.88 9.5 26.5 - 165.1 mm 6.500 165.1 6.625 149.4 5.88 340.6 13.41 25.4 1.00 190.8 7.51 236.7 9.32 114.3 -- 4.50 4, 40.6 1.60 47.8 1,88 ' 12.0 26.5 6 150 168.3 149.4 340.6 25.4 190.8 236.7 114.3 40.6 47.8 12.0 8 8.625 5.33 1 16.50 1.27 9.65 10,98 6.30 0.00 0.68 43.0 200 219.1 10.750 135.4 6.40 419.1 19.14 32.3 1.72 245.1 12.20 278.9 16.19 4, 160.0 9.00 0.0 17.3 19.5 - 80.0 10 250 ________ 2730 12.750 1626 6.50 4862 21.54 437 - -.-... 2.66 3099 - - -----± 14.25 . ---- 4112 17.22 - 2286 t---- 9.00 - --- - --_______ 363 102.0 12 300 323.9 165.1 j 547.1 67,6 362.0 437.4 I 228.6 - " 46.3 * On Centerline *These dimensions apply only to a Series 705W Butterfly Valve with a ½-inch NPT, supply-side tap To prevent rotation of valves. it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex, Style 005 FireLock, Style 0091009V FireLock EZ, or Style HP-70 Rigid Couplings. If Victaulic flexible couplings are used, additional support may be required. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IFS) only. Not permitted for use with plain end (lPS) pipe. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. -'I- !P" . *IIv huh hiIih1 2½ - 4-INCH/65 - 100-MM SIZES J! hUll' 1111111' 5 - 12-INCH/125 - 300-MM SIZES www.victaulic.com vICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. 10.18_2 'tauIic REV_H IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR DIMENSIONS— (] 06 C®US <e> ILPCBI LISTED On Centerline t These dimensions apply only to a Series 705W Butterfly Valve with a ½-inch NPT, supply-side tap To prevent rotation of valves. it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex. Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP-70 Rigid Couplings. If Victaulic flexible couplings are used. additional support may be required. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only. Not permitted for use with plain end (IPS) pipe. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. fl °1 •••ir 111111 jIIiiI 76.1MM - 4-INCH/65 - 100-MM NOMINAL SIZES 139.7MM - 12-INCH/125 - 300-MM NOMINAL SIZES www.victaulic.com \J(tauIic.° VICTAULIC IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. 0 2008 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_H 10.18_3 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR PERFORMANCE The Chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. MAXIMUM WORKINGS PRESSURE RATINGS www.victaulic.com 'JtauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.18_4 REV_H IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR PERFORMANCE C, values for flow of water at +60°F/+16°C with a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for 0v Values: LID = Q2 Where: 0= Flow (GPM) AP = Pressure Drop (psi) 0 = C x C = Flow Coefficient Formulas for Kv Values: AP = Where: - <v Q=Flow I m O = K x AP = Pressure (bar) K = Flow Factor www.victaulic.com ictaulicr vIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_H 10.18_5 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1. The supervisory switch contains two, single pole, double throw, pre-wired switches. Switches are rated 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps © 250 VDC Switches supervise the valve in the open" position. One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 MTW ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Si Normally Closed: (2) Blue Common: (2) Yellow S2 f Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe ULLISIAT JU NC TON FIRE A LA RH CO IRTA 0 C PA N EL CONDUIT SUPEROSORY CIRCUIT SWITCH WWT CONTACT RATING 100 AT ITS MAO 2UOVA CTSRUOTCONNECTOW USA AT 125 VDC 025AT250UDC WIRE NUTS GOLTAUS SOURCE prisJ. iIJ:L SwItch 1:2 leads per lermina S1I11h2:1 lead pee Ie,mlnal NOTE: The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe —S2) and the normally closed terminal (blue - 51 and blue-with-orange stripe - S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). www.victaulic.com vIcTAuuC IS REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. © 2008 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. 10.18_6 J -C tauIic REV_H SERIES 705W Will-I WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve. Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the 1-100 Victaulic Field installation Handbook. III IIMIlIIIIMIIIIIIIlIIIIIIIIIIIIlI 11111 WCAS-7H FF85 For complete contact information, visit www.victaulic.com \,i4tauIic 10.18 2466 REV UPDATED 8/2008 vICTAuLIC IS REGISTERED TRADEMARK OF vlcTAuuc COMPANY. © 2008 vICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.18 F P P I UL, ULC and FM Description Check valves feature cast brass* bodies with a spring loaded clapper assembly making this valve suitable for vertical or horizontal installations. Features metal faced clapper with 0-ring seat. Rated to 300 psi. Valve bodies are tapped and plugged ½" IPS for additional equipment such as a ball drip valve when used in conjunction with a Fire Department Connection or a pressure gauge when used in a supply line. Installation Install in accordance with approved installation practices. Use an approved thread sealant such as PipeFit Thread Sealing Paste with PTFE on all threaded connections. Make sure that proper lubrication has been applied to groove coupling gaskets for groove end valves. DO NOT OVER TIGHTEN THREADED CONNECTIONS. OVERTIGHTENING MAY CAUSE DISTORTION OF THE BODY AND THREADS OF THE VALVE LEADING TO IMPROPER PERFORMANCE AND PRODUCT FAILURE. Specifications Material: Cast Brass* Pressure Rated: 300psi Approximate Size: Take-Out +/ 1,4": 2" IFS 6½" 2½" IFS 7" 3" IFS 6,4" 4" IFS 8" Configurations: (Inlet x Outlet) MNPTxFNPT MNPTxGRV GRVxGRV *Contains lead. Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX +1800344-3775 © 2012 Fire Protection Products, Inc. C@ <*> LISTED LISTED APPROVED Series 717 (21h - 3/65 - 80mm) Series 717 (4-12/100-300mm) t) - Series 717H High Pressure Check Valve (2— 3/50 - 80 mm) SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD- designed for hydrodynamic efficiency and available in 2/50mm - 3780mm (Series 717H) and 2½"/65mm - 12"/300 mm (Series 717) sizes. Series 717H valves are CULLS Listed and FM Approved for service up to 365 psi/2517 kPa. See chart below for approved services for the Series 717 valves. In both valve designs, the single-disc mechanism incorporates a spring-assisted feature for non- slamming operation. This spring-assisted, single-disc design achieves a leak-free seal with as little as 5ff /1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically (flow upwards only) or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted to flanged (ANSI CL.150) equipment using either to Victaulic Style 741 Vic-Flange® or Style 744 FireLock flange adapters on either end. Approval/Listing Series Size cUlus ' FM Service Pressures 717H LPCB Vds 2/50mm upto365ps/25l7kPa up to 365pu/2517kPa up to 365 psu'2517kPa up to 365 po/2517kPa 21/Y765mm upto 365psV2517kPa up to 365ps1/2517kPa_ up to 365 psi/2517 kPa' upto 365 psi/2517kPa 76.1 mm J up12 up to 365p51/2517kPa upto365ps1/25171<Pa up to 365ps1/2517kPa 3780mm f up to 365 psi/2517 kP up to 365 psi/2517 kPa up to 365 pti/2517kPa up to 365 psi/2517 kPa 47t00 mm Wa rVa rVa n/a 57125mm rVa j rVa rVa rVa 139.7mm rVa ru/a rVa ru/a 67150mm ru/a ru/a ru/a rVa 165.1 mm rVa j ru/a rVa - rVa 87200mm rVa rVa ru/a n/a ru/a rVa 10'/250mm ru/a rVa 127300mm n/a I rVa Wa rVa Approval/Listing Service Pressures Series 717 LIII: VdS - 2'50mm fl/a n/a n/a rVa 2½765rnm j up to 250pui/1725 kPa n/a up to 365 psi/2517kPa fl/a - 76.1 mm up 25P n/a up to 365 psi/2517 kPa up to 16bar/232p 3780mm J up to 250psV1725 kPa fl/a up 10365 psi/2517 kPa up to 16bar/232 psi 47100mm j up 10365 psV2517kPa . up to 365 psi/2517 kPa up 10365 psi/2517 kPa up to 16bar/232 psi 57125mm up to 365p51/2517 kPa up 10365 psi/2517 kPa up 10365 psi/2517 kPa n/a 139.7mm up to 365p51/2517 kPa up 10365 psi/2517 kPa up 10365 psi/2517 kPa up to 16bar/232 pul 67150mm L up to 65 V2517 kPa up to 365 psi/25t7kPa -. up to 365 p51/2w 7 kPa upto 16bar/232 psi 165.1mm up 10365 psi/2517 kPa up 10365 psi/2517kPa up to 365 psi/2517 kPa fl/a 8'/2O0mmJ upto365psV2517kPa upto365psV2517kPa up50348ps1/2400kPa upto16bar/232p 107250mm I up to 250psVt725 kPa up to 250p5i/1725kPa up to 1725 kPa/250p5i fl/a 127300mm upto250psVl725kPa upt0250ps1/1725kPa up to 1725 kPa/250 psi fl/a JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Approved WWW.VICTAULIC.COM vicTAuLic IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. 02011 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_P \4taulicr 10.08_i IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB DIMENSIONS - Series 717 TYPICAL 2½ - 3/65 - 80MM A— Rj,_ J 4i 0 ½ NPT Upstream Drain 0 ½ NPT Downstream Drain l 2 NPT (Drain Optional( TYPICAL 4-8/100 - 200MM P~ B 0½ NPT Upstream Drain 0 W NPT Downstream Drain TYPICAL 10- 12/250 - 300 MM DIMENSIONS - Series 717H r -=- TYPICAL 2760.3 mm - 3788.9 mm www.viCtauIic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X. Ac—t a —ul i a 10.08_2 REV_P IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.08 FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB MATERIAL SPECIFICATIONS Body: Ductile Iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Body Coating: Series 717H Body: Black Paint Series 717H Endface: Electroless Nickel Series 717 (21/2 - 31 PPS Coating Series 717 (4— 121: Black Paint Body Seat: Series 717H - Nitrile 0-ring installed into an electroless nickel plated endface Series 717 (21/2 - 3"1 PPS Coated ductile iron Series 717 (4— 12"): Welded Nickel Disc Seal or Coating: Grade "T" Nitrile (Series 717H ONLY) Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/-i-60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. Grade "E" EPDM (Series 717 ONLY) EPDM (green color code). Temperature range -30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: Series 717H (2— 3/50 - 80mm): CF8M Cast Stainless Steel Series 717 (21/2 —3"): Aluminum bronze with elastomer seal Series 717 (4— 12/100-300 mm) Elastomer-coated ductile iron Shaft: Series 717H (2— 3/50 -80 mm): Brass Series 717 (2½ —3"): Type 416 Stainless Steel Series 717 (4— 12/100 —300 mm) Type 316 Stainless Steel Spring: All sizes Type 302/403 Stainless Steel Shaft Plug: Series 717H (2— 3/50 —80 mm): Type 416 Stainless Steel Series 717 (21h - 12/65 — 300 mm): Carbon steel zinc plated Pipe Plug: Series 717H (2— 3/50 —80 mm): carbon steel zinc plated Series 717 (4— 12/100 —300 mm): Carbon steel zinc plated www.victaulic.com vIcTAuLIc IS REGISTERED TRADEMARK OF viclAuLIc COMPANY. © 2011 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. REV_P \LtauIic 1O.08_3 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.08 FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cUlus, FM, VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 60°F/16°C through valve. 5717H/717HR 10 100 FLOW RATE - G.P.M. 5717H / 717HR 100.00 tA Ln 0 _i 10.00 1.00 4.- 100 1000 FLOW RATE (Litres/Mm) www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.08_4 \ 4tauljcr REV _P 1000 10000 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 1'I'i FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 60°F/16°C through valve. S717 I 717R 10 100 1000 10000 100000 FLOW RATE - G.P.M. 5717 / 717R 100.oc .00 10.00 100 1000 10000 100000 FLOW RATE (Litres/Mm) www.victaulic.com \1/tauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVP 10.085 SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB INSTALLATION Series 717 and Series 717H Check Valves can be installed either vertically (flow up only) or horizontally (with hinge on top) - making sure the flow arrow matches the flow direction through the pipeline. Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at w.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.08 1479 REV P UPDATED 6/2011 ictaulic. VICTAULIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.08 OITAt4 FIRE PROTECTION 6) Hangers 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com Fig. 200-21/2 10200-8 Fig. 200 Fig. 200S Fin 900 - I'M mline" ArIiiistihIp Rind Hinnar monner R-I me Fin B317ONFI ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) C@ USTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut FM Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - -' keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. / For hanger with non-captured nut order Fig. 200S. / (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. / Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°c) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FMDS2-0. Fig. 200C Fig. 200F Part No. ' Pipe 1/211 (15) ' Size /8-16 A B Approx.)/1 II (50 200-3/4 3/4 (20) 3/8"-16 31/8 (794) 21/2 (635) 11 (5 .0) 200-1 1 (25) I8-16 3I8" (85.7) 2I8" (66.7) 12 (5.5) 200-11/4 11/4 (32) 3/8"-16 33/4 (940) 2/8 (730) 13 (59) 200.11/2 11/2 (40) /8"-16 3/8" (98.4) 2/81, (73.0) 14 (6.4) 200-2 21' (50) I8"-16 41/2" (114.3) 3° (76.3) 15 (6.9) 200_21/2 21/2 (65) I8-16 5I8 (142.9) 41/8 (104.7) 27 (12.3) 200-3 1 3 (75) 1 3/8"-16 5I8° (149.1) 4° (101.6) 29 (13.3) 200.31 /2 31/2° (90) /8°-16 7 /8° (187.3) 51/4 (133.3) 34 (15.6) 200-4 4° (100) /8°-16 7/8° (187.3) 5° (127.0) 35 (16.0) 200-5 5° (125) 1/2"_13 91/8° (231.8) 61/4° (158.7) 66 (30.2) 200-6 6" (150) 1/2"_13 101/8" (257.2) 6/4 (171.4) 73 (33.4) 200-8 8 (200) 1/2"_13 131/8° (333.4) 8/4 (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PPI COOPER B-Line Fig. 20021I2 to 200-8 Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - - - - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily 7 installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig 200-1 to 200-2 Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size '1 Designed to meet or exceed requirements of FM DS 2-0. Part No. 200M8-1/2 Pipe in. 1/2 Size I (15) Rod Size M8 I 31/8" A (79.4) 2/8° B (66.7) 11 I Approx. }'l'14II I (5.0) 200M10-1/2 1/2 ' (15) M10 31/8' (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4' (20) MB 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4' (20) M10 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200111018-1 1" (25) M8 33/8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1" (25) M10 3/8" (85.7) 2/81, (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200M8-1112 11/2" (40) M8 3T/8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" 1 (40) M10 3/8" (98.4) 2/8" (73.0) 14 (6.4) 2001V18-2 1 (50) MB 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 (50) M10 41/2" (114.3) (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8' (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7 /8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (100) M10 7/8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M 6 6 (150) M12 101/8 (2572) 6/4 (1714) 73 (334) 200M-8 8" (200) M12 131/8" (333.4) 8/4" 1 (222.2) 136 1 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Iv] -71 l i i i Fig. 200H — Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to 640 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2"_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Pipe Size 200H-2-3/8 2 (50) I 3/8"-16 4/16 Rod Size Approx. - (115.9) 3T/32 - (81.7) 48 '' II (21.8) 200H-2-1/2 2° (50) 1/2"_13 423/32' (119.8) 33/8" (85.7) 45 (20.4) 200H-21/2-3/8 21/2" (65) /8"-16 5/16" (134.9) 3/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2' (65) 1/2"_13 515/33" (138.9) 3/8" (98) 56 (25.4) 200H-3-3/8 3" (75) /811-16 53/4' (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3 (75) 1/2"13 57/8" (148.1) 331/32" (100.8) 60 (27,2) 200H-4-3/8 4" (100) I8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4 (100) 1/2"..13 71/32' 1 (178.6) 1 419/32" 1 (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line SPA'"EMMYSO FOR WOOD No pie-drilling required. Quick to install using the Sammy Nut Driver with an iSV cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. C.._.) Watch a video demoest,atioe at www.itwbuildex.com a - #14 Black Nut Driver Part # 8113910 1• #14 SW Red Nut Driver Part # 8114910 1/4 8002957 GST 100 1/4x1" 25 125 1/4° 8003957 GST 200 1/4 x 2° 1760 (Fir) 25 125 1/4° 8004957 GST 300 1/4 a 3" 2060 (Fir) 25 125 210 (7/16"OSB) 3/8 8007957 GST 10 1/4 x1" 300 25 125 3/8 8008957 GST 20 1/4x2° 1760 (Fir) -- 850 1475 25 125 3/8 8068925 GST 20-SS 1/4x2 1760 (Fir) 850 25 125] 3/8' 8009925 GST 25-380 318x2-1/2" 2113 (Fir) 1500 25 125 [Q8 8010957 GST 30 1/4x3 - 2060 - 1500 1475 251251 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 I 3/880925 - 04x4 2180 (Fir) 25 J 1/2 8013925 GST2 1/4x2 1760 (Fir) 25 125 8014925 GST 2S-380 3/8x2 2113r) 25 125 1 1/2° 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 ARX V 100"W%, %W MAN NU. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 25 125 25 128 * May require pre-drilling; consult joist manufacturer. #14 Black Nut Driver - Part# 8113910 1 #14 SH Orange Nut Driver Part # 8273910 1/4x2" 1257 (Fir) 1050 1475 1/4x 3"1720 (Fir) 1500 .......J2L. - 1903 Dim. Lumber 1500 5/1160-3/4" 1406 @ 45°off vertical 850 @45° Dim. Lumber 903 Dint. Lumber 0 5/160-3/4" 1-3/4" 1406 @ 45°off vertical Dim. Lumber W4S@ No pie-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Not less than 2" nominal width (1-1/2") opts 3-1/2" pipe; not less than 3 (2-1/2") nominal width 4" & 5" pipe 4 Floor Joist 11 Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. ExcepUsn: This requirement shall nut apply to 2" or thicker nailing strips resting on top of steel beams, Consult t recommer Pre-drilling r. Watch a video demonstration at www.itwbulldex.com MOUNT 1/4 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 -3/8' 8020957 - SWG10 1/4x1° 622 (fr( 300 25 125 €1. - [-HORIZONTAL 3/8 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 - [ 3/8 8073925 _______ ) SWG2O-SS 1/4 x 2 1725 (Ri 850 25 1251 3/8* 8022925 SWG 25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 14 SW Red [ 3/8 8023925 SWG 30 -- 1/4 x 3" 1884 (Fir) 25 1251 Nut Driver Part #8114910 May require pre-drilling; consult joist manufacturer ,IMCEk frflf MAXNnLEW Eliminates distortion of threaded rod. "Accommodates up to 3 Y2" x 12 pitch roof. "Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. 8150922 8153922 XP 35 3/8" 8181922 XP 200 1/4" 8294922 SXP 20 3/8" 8295922 SXP 35 3/8" 8293957 SWXP 35 3/8" 250 .035" 185 .027" 250 .035" 185 .027" 250 .035" 170 .027" 80 .027" 250 .060" 80 .060" 80 .060" Vertical Vertical Vertical Vertical 45" Vertical 90" Horizontal APPROVALS 8007957 GST1O - 3/8" Vertical CPVC1-1/2" 300 1-1/2' 8020957 SWG 10 3/8' Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST20 3/8 Vertical 21/2 850 11/2 4 1475 11/2 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST30 3/8 Vertical 4 1500 11/2 . -1/2'.4 1475 11/2 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8' Horizontal 3-1/2"-4"" 1500 1-1/2" - 8021957 SWG 20 - 3/8" Horizontal 2-1/2" -3'** - 1050 1-1/2" - - - - 8073925 SWG20-SS 3/8" Horizontal 2-1/2" 850 1-1/2 8269957 SH-GST/CST2O 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" r 8269957 SH GST/CST2O 3/8 45 Angle off Vertical 4 1500 - -. 11/2 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" SAMMYS FOR STE EL7 PIPE HANG ER 6IT111TflIIiV Max Steel 8038957 DSTR1 3/8" Vertical 1500 .035" 4" 1475 .105" 8037957 DSTR1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" [8039957 DSTRS16 3/8 Vertical 4 1500 - -- 037 4 1475 105 J 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK5O 3/8" - Vertical - - 4" 1500 .250" 4 1475 - - .188" 8055957 SVVDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 18056957 SWO R 516 -. 3/8" - Horizontal 4" - 1500 ." 037 4" 1475 _______ .060" -.66-0'- - - 8054957 SWDR1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" .. 8137957 SH-DSTR1 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK5O 3/8" Vertical 2-1/2" 850 -. 70" Angle off Vertical 4" 1500 - 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2' 940 - ..- ... O2 8153922 XP 35 3/8" Vertical 4" 1500 .060" 4" 1475 8294922 SXP2O - 3/8" - Vertical or up to 45' - 2" 750 .027" - 2" 635 - .029" 8295922 SXP 35 3/8" Vertical orspto89" 3-1/2" 1250 .060" 2' 635 .029" 1 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 .060" - 8059957 CST 20 3/8" Vertical . 4" 1475 3000 8061957 SWC 20 3/8" Horizontal - 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural@3000psi 8150922 XP 20 3/8' Vertical 2-1/2" 850 Post-Pour Ranne II LWC 5 35 PCF (lbs/it) 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit L 8294922 SXP 10 3/8 Vertical 283 027 Max 4 trade size EMI RMC and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP35 3/0" Horizontal 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, F ISheet Steel tGauges Complies W/ NEC Standards Gauge No. 22g9. 209a. 18ga. 16ga. 149a. gk. 3/16" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" "SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" UL compliance with NEC Standards. * i j SWG 25-380 Maximum pipe size n wood timber or joist allowed by UL is 4 UL and FM tests were performed in compliance with NFPA 13 Standards. **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112" -"-5-.--, b-.'" '- Fastening requirement 5 times weight of water-filled schedule 40 pipe plus 250 pounds. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4' 3/8'c 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #145 W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer not and torque to 20 foot lbs. for maximumpullout in purlin steel. H Hifl1 Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14S W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8' Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. 4iIRü Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4' 3/8' 1/2' or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14S W (red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. doing so will destroy the pullout factor of the screw. ____ A irirriri r IE 4 r IF.9T21 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, conllnue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate net driver for installations. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the canter of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pie-drilling may be required by joist manufacturers. If so, pie-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Size GST 20 .182" 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pie-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com U TED AUO LETED AS - A0 CABLE -E *L$OLThDASMCHORFORLUWaRE mi Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and igs. Made in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 A JJITAtl FIRE PROTECTION 7) Sway Bracing 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com ® Listed Max. Horizontal Load System NPS Sch. 30-44 45-59 60-89 90 1,,_1 1/2' 1D4 1956 2394 2765 2"- 4" - " 1 i i 2394 2765 5.1 1 1383 1956 24 27 1383 1956 2394 2765 10" 10-40 1383 1956 2394 2765 12" 40 70 25 1 3238 1 314U 0 Certified Max. ASD Horizontal Loads System NPS 1" Sub. 30-44 45 -59 60-74 75-90 -1 1/2 14 1680 2380 2920 3250 2-3' 10,40 1800 2350 3120 3490 4" 10,40 _.172. ..1930 270. 2640 5,6,8" 10,40 730 1040 1270 1420 * SPECIALLY LISTED PIPE AS I Fipen P VT LTD Al Jazeera Sleet Products Co. SAOG Allied Tube & Conduit Corp. Bihar Tubes LTD. Bluesteet Services L L C Bonasan Mannesmann Born AS Butt Moose Tube Co. Corners Metal Supply LTD. Hai Chin Worldwide LTD Hickman Pipe & Tube Corp. Jiedoug Economy Development Testing Zone Jitsdat Industries LTD Jotindrn Sleet & Tubes LTD Mittal Canada Inc. MS Pipe Cu. LTD Northwest Pipe Co. Pacific Pipe Public Co. LTD Sobs Thai Stool Pipe Public Cu. LTD Shield Fire Safety & Security LTD Ssuya Roshini LTD Swaslik Pipes LTD Ton-Tube Co. Universal Tube & Plastic Industries LTD Wcifang East Pipe Industry Technical Co. LTD Welded Tube. Berkeley LLC Wheatland Tube Co. WIt Div. Yich Pltoi Enterprise Co. LTD Youngstown Tube Co. Zenith Birla (India) LTD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL K I thru 4 Inch pipe 5 thru 12 inch pipe SIZE -SYSTEM PIPE: Nominal Steel 1" thru 12" * Steel Specially listed - see chart. CPVC l"thru3". Brace common O.D. - Copper, Plastic, FRP, Ductile and Cast Iron SIZE - BRACE PIPE: 1" thru 2" Sch. 40 Mm. 11/411 required for 12" system pipe MATERIAL - Carbon steel and ductile iron. FINISH - Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL - 203A EX 2625 LIM FM Approved - 1950 OSHPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented - designed for system pipe of varying material. * Improved assembly - extra large bore for brace pipe. * Visual inspection, verifies proper installation. * Superior load ratings. ORDERING - Part #, size - system pipe, size - brace pipe and finish. * COMMONLY KNOWN AS SCH. 7 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When condition exists - shift mounting location. Specific AFCON products are exclusively designed lobe compatible ONLY with oltaerAFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hunger assembly. Be advised the following warranty restriction will apply. DISCLAEMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold byAFCON. AFCON shall NOT be liable tinder any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to lass of business or profit, when non-AFCON products have been, or are used. 3/13 1. j iii APPROV!D Included Fig. 1000 - "Fast Clamp" Sway Brace Attachment Size Range: Pipe size to be braced: 1(25mm) thru 4" (1 00mm) 40 IPS.* Pipe size used for bracing: 1 (25mm) and 11/4" (32mm) Schedule 40 IPS. * Maximum horizontal design load is 655 lbs. (2.91kN) Torque requirement is 6-8 ft./lbs. (8-10Nm). For pipe sizes larger than 4" (100mm) please refer to TOLCO Fig. 1001. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Features: Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation: Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe and Cooper B-Line/TOLCO structural attachment component, Fig. 980 or other approved TOLCO seismic brace to form a complete bracing assembly. Follow NFPA 13 guidelines. To Install: Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals: Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 62. Application Note: Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1 pipe extension beyond the Fig. 1000 is recommended. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4" (32mm)) , and finish. Designed to meet or exceed requirements of FM DS 2-8. Pipe 1000-1 X 1 71.6 Part Number & Approx. Wt./1 00 (32.5) 10001 X11/4 I .. Horizontal .'. i Installation 11/4" (32) 1000_11/4 X 74.8 (33.9) 1000_11/4 X 11/4 79.1 (35.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1,69) 11/2" (40) 1000-11/2X 1 77.8 (35.3) 1000-11/2 X 1I4 82.1 (37.2) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) (50) 1000-2 X 84,1 (38.1) 1000-2 X 11/4 88.4 (40.1) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) 21/2" (65) 1000_21/2 X 90.2 (40.9) 1000_21/2 X 11/4 94.6 (42.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) (80) 1000-3X1 97.3 (44.1) 1000-3X1114 101.7 (46.1) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.00) 31/2" (90) 1000_31/2 X 104.0 (47.2) 1000_31/2 X 1I4 108.4 (49.2) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.00) 1 (100) 1000-4 X 1 110.3 (50.0) 1 1000-4 X 1I4 114.6 1 (52.0) 1 230 1 (1.02) 1 320 1 (1.42) 400 1 (1.78) 1 450 1 (2.00) 1 FM Approved when used with 1, 11/4,11/2, or 2 inch NPS Schedule 40 GB/I 3091 EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/I 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/I 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line ®TOLCO APPROVED (7 Fig. 1001 -Sway Brace Attachment Size Range: Pipe size to be braced: 21&" (65mm) thru 8" (200mm) IPS. * Pipe size used for bracing: 1 (25mm) and 11/4 (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 64. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1(25mm) or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the FM Approval requires that Fig. 1001 must be used only with other Cooper B-Line/TOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. Pipe I 21/2' (65) 1001_2112 X 11138.6 Part Number Lbs. (62.8) & Approx. Wt./1 00 1001-21/2 X 11/4 160.4 (72.7) Design 800 Load - Allowable Horizontal (3.56) 1130 (5.02) Capacity 1380 (6.14) (lbJ Per Installation 1540 1, 2 3 (6.85) (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 190,0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" 1 (200) 1001-8 X 217.4 1 (98.6) 1 1001-8 X 11/4 1 238.8 1 (108.3) 1 510 1 (2.27)1 730 1 (3.25) 1 890 (3.96) 1 990 1 (4.40) 1 FM Approved when used with 1, 11/4,11/2, or 2 inch NIPS Schedule 40 GB/T 3091 EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as 'Schedule 7". These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. .1. oo COOPER B-Line ®TDLCO APPROVED pf Rnit & I1ri1wrp InrIiii1pi1 4-Way Riser Brace (plan view) Fig. 41 - Longitudinal "In-Line" Sway Brace Attachment Size Range: 21/2 (65mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Approved by Factory Mutual Engineering (FM), 21/2 (65mm) through 8" (200mm) pipe. For UL Listed information refer to page 46. Installation Instructions: Fig. 4L is the braced pipe attachment component of a longitudinal sway brace assembly. It is intended to be combined with the bracing pipe" and Cooper B-Line/TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage bracing pipe" into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8. Longitudinal Brace 4L-2112 Pipe 21/2" (65) 67/16 (1635) 21/2 (63.5) 2/4" (69.8) 1/2"_13 1030(4.58) *Max. Design 1180(5.24) Load (FM) 1420(6.31) 1590(7.07) Approx. 253 (114.7) 41-3 (80) (177.8) 2/4" (69.8) 31/16" (77.8) 1/2"..13 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) 268 (121.5) 41.-4 (100) 81/2 (215.9) 3/8" (85.7) 311/16" (937) 1/2"..13 530(2.36) 730(3.25) 890(3.96) 990(4.40) 348 (157.8) 41-5 (125) 93/4" (247.6) 3I8" (98.4) 4/8" (1111) 1/2"_13 530(2.36) 730(3,25) 890(3.96) 990(4.40) 380 (172.3) 4L-6 (150) 111/2" (292.1) 5" (127.0) 51/8" (130.2) 1/2"_13 530(2.36) 730(3.25) 890(3.96) 990(4.40) 640 (290.3) 41-8 1 8' 1 (200) 1 131/4" 1 (336.5) 1 5/8" (142.8) 5/8"1 (142.9) 1/2"_13 1 490(2.18) 1 680(3.02) 1 830(3.69) 1 930(4.13) 1 728 1 (330.2) FM Approved when used with 1", 11/4, 1112" or 2" Sch. 40 brace pipe. FM Approved design loads are based on ASD design method. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 4A - Pipe Clamp for Sway Bracing Size Range: 4' (100mm) thru 8" (200mm) pipe. For sizes smaller than 4" (100mm) use B3140. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 4" (100mm) thru 8" (200mm). Installation Instructions: Fig. 4A is the braced pipe attachment component of a longitudinal, lateral or riser brace assembly. It is intended to be combined with the bracing pipe and Cooper B-Line/TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 4A over the pipe to be braced. Attach Cooper B-Line/TOLCO transitional fitting, either Fig. 980, 910, 909, or any other Cooper B-Line/TOLCO approved transitional fitting. Tighten bolts and nuts; torque requirement is a minimum of 50 ft/lbs. (68Nm). Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish Note: Please refer to Fig. 4L for longitudinal brace applications for 2" (50mm) - 8" (200mm) pipe sizes. ®TDLCO c®us LISTED nnus ana nex Iluls incivaeo Fig. 4ALongitudinal Brace Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. B3373 - Standard Riser Clamp (TOLCO Fig. 6) Fig. B3373C - PVC Coated Standard Riser Clamp (TOLCO Fig. 61PVC) Size Range: (B3373) 1/2° (15mm) thru 30° (760mm) pipe (B3373C) /2° (15mm) thru 6° (150mm) pipe Material: Steel Function: Used for supporting vertical piping. Approvals: Underwriters Laboratories Listed in the USA (UL), Canada (cUL) 3/4 (20mm) - 8 (200mm). Factory Mutual Engineering Approved, 3/4 (20mm) thru 8° (200mm). Conforms to Federal Specification WW-H-171E & A-A-1192A, Type 8, and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 8. Maximum Temperature: 650°F (343°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-0. ®TOLCO c®uS LISTED Design Load no B3373C B3373-112 Pipe Size 1/2 (15) 9 L (228.6) Bolt Size I 3/8"-16 x 11/4 Approx. 101 Wt./100 11 (45.9) B3373-3/4 3/4 (20) 91/4° (234.9) 3/8 '-16x11/4° 105 (477) B3373-1 1° (25) 9/16° (242.9) 3/8°-16x11/4° 109 (49.4) B3373-11/4 11/4° (32) 101, (254.0) I8°-16x11/4° 112 (50.9) B3373-11/2 11/2 (40) 101/4 (260.3) 3/8°-16x11/2° 113 (51.1) B3373-2 2 (50) 10/4° (273.0) 3/8°-16X11/2° 165 (75.0) B3373-2112 21/2 (65) 111/4° (285.7) 318°-16X11 /2" 180 (81.6) B3373-3 3° (80) 1115/16 (303.2) 3/8"-16x11/2° 195 (88.4) B3373-3112 31/2 (90) 12/8° (314.3) 1/2°-13x13/4° 217 (98.5) B3373-4 4° (100) 12/8° (327.0) 1/2°-13x13/4° 228 (103.5) B3373-5 5° (125) 14 (355.6) 1/2°-13x13/4" 480 (217.7) B3373-6 6° (150) 15/16° (385.8) 1/2°-13X2° 526 (238.6) B3373-8 8° (200) 17/4° (450.8) /8-11 x21/2° 957 (434.1) B3373-1O 10° (250) 19/16' (493.7) /8°-11 x2112° 1101 (499.4) B3373-12 12° (300) 2111/16° (550.9) /8°-11 x3° 1622 (735.7) 6373-14 14° (350) 23I16° (598.5) /8'-11 x3° 1732 (785.6) Notes: For ductile iron (0.1.) pipe use part number B3373C1-pipe size. Contact B-Line 0- E Engineering for more information. 0 0) AL For larger sizes, consult the full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp- 00 COOPER B-Line Fig. 907 - Multi-Angle Attachment Size Range: 1 "(25.4mm) x 1(25.4mm), 1(25.4mm) X 11/4" (31.7mm) and 11/4" (25.4mm) x 11/4' (25.4mm) bracing pipe. Material: Steel, hardened cone (or cup) point set bolt Function: For attaching two pieces of pipe together at various angles. Can be used as OSHPD Pre-Approved Seismic Bracing assembly. Approvals: Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the Cooper B-Line/TOLCO Seismic Restraint Systems Guidelines. To Install: Attach the Fig. 907 over one piece of pipe and adjust to desired position. Tighten set bolt until head bottoms out on surface, then repeat the process for the second pipe. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, bracing pipe sizes and finish. Cooper B-Line, Inc.'s ('Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line ®TOLCO APPROVED Set Bolt Included Mounting Hardware Is Not Included Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Designed to meet or exceed requirements of FM DS 2-8. Fig. 4L 0 Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" Size Range: One size fits bracing pipe 1 '(25mm) thru 2 (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31.7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe and Cooper B-Line/TOLCO braced pipe" attachment, Fig. 1000, 1001, 4L, or other TOLCO approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the bracing pipe. Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 60. Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L or other TOLCO approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. * Standard size. ** Mounting attachment hole size. Installed with 1" or 11/4" Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Lines warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line A ITAN FIRE PROTECTION 8) Accessories 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com (65-10-150) Knockouts and shelf to accommodate any 1/2" or 6 Head Box 3/4" sprinkler head All-welded construction and full length hinge Red powder coated finish Slotted for easy mounting with screws, rivets or strapping 6 Large Head Box (65-10-151) (65-10-151A) ARGCO FIRE SPRINKLER SPARE HEADBOXES Heavy gauge steel construction 3 Head Box 12 Head Box H 3.5'F3.325' ii I 7.25 (65-10-152) The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM FireLock® Escutcheons Victaulic FireLock Escutcheons are intended for use with Victaulic FireLock V24, V27, V29, V33, V34 and V36 recessed, flush, and extended pendent sprinklers. They are intended for use only with Victaulic FireLock sprinklers. Agency Approvals and Listings for Victaulic FireLock sprinklers require the use of Victaulic FireLock escutcheons exclusively. FireLock escutcheons are not Listed or Approved for use with any sprinklers other than Victaulic FireLock sprinklers. FireLock escutcheons are available in various finishes to meet many design requirements and are intended only for use with Victaulic sprinklers. Please reference the 1-40 Installation Manual before installing any product. NOTE: The V33 and V36 escutcheons are offered as part of a pre-assembled sprinkler product and are not available for individual purchase. V29 EXTENDED V29 FLUSH ESCUTCHEON ESCUTCHEON rTT V27 AND V34 RECESSED V27 AND V34 FLUSH ESCUTCHEON ESCUTCHEON TECHNICAL SPECIFICATIONS: Material: Cold Rolled Steel Optional Materials: Brass Stainless Steel Finishes: Chrome White Custom NOTE: All Nickel Teflon* sprinklers must use stainless steel escutcheons. Stainless steel and brass options are available painted black, white or custom. See current Price List for complete offering. For expansion plate information, please refer to submittal publication 40.84. * Teflon is a registered trademark of Dupont Corporation. !I'1I80i1I CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-13 \4taulicr 40.88_i FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLER ACCESSORIES 4088 FireLock® Escutcheons FOR RECESSED OR FLUSH SPRINKLER INSTALLATION -o 021/16"/ 65.10 mm 1/27 15.91 mm 12.70 MM V29 EXTENDED ESCUTCHEON '129 FLUSH ESCUTCHEON 73:2787 03 mm R21'/16771.37 3.18mm I *Adjustment to Nor W/19.05 28.58 or 20,64mm W 12.70 mm or 12.70 mm '127 AND '134 RECESSED ESCUTCHEON V27 AND V34 FLUSH ESCUTCHEON * NOTE: THIS ESCUTCHEON CAN BE ADJUSTED TO RECESS ½ OR 3/4"/12.70 OR 19.05 MM www.victaulic.com JtauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 40.88_B REV _B Escutcheons FOR RECESSED OR FLUSH SPRINKLER INSTALLATION WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 212011 40.88 6321 REV B viclAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2011 vicTAuLic COMPANY. ALL RIGHTS RESERVED. , Ill -U1 -1 d 40.88 F P P I Description Manufactured from .020" white coated aluminum. All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation directly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Installation Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the sign on the area being identified. Since all of the above mentioned signs are predrilled at all four corners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the appropriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to the base material. (The 9" x 7" Fire Alarm Bell sign must be drilled with a /8" hole if it is to be attached directly to the bell gong.) Specifications Material: .020" aluminum with removable plastic coating Sizes: 6" x 2" x 6" x 7" 9" x 7" 12" x 10" 8.5" xli" 7" Round See current catalog for a full listing of all available signs. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 0 2012 Fire Protection Products, Inc. F P P I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -10° to 150° Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G FBC5 SYSTEM COMPATIB*.E *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 2Ib (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 © 2012 Fire Protection Products, Inc. FPPI° LubeHt® are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ, Blaze-Master®, FlowGuard Go/cl® and Co,zan® are registered trademarks of Noveon IP Holdings Corp. --/ kA 0 MADE IN U.S.A. F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FBC/'. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC igi. 5 gl. 55g1. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com © 2012 Fire Protection Products, Inc. FPPI5, LubeFit® are registered trademarks of Fire Protection Products, Inc. LA FBC', BlazeMaste,, FlowGuard Gold" and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Th1 r'i F P P I Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Threi1FtF Th,.od C.,Ang O UK -I © 2013 Fire Protection Products, Inc. FPPI5, ThreadFit are registered trademarks of Fire Protection Products, Inc. CA MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FR.C/1 SYSTEM COMPATIBLE *FBC System Spears® Compatible Compatible indicates indicates that this product has been ThreadFit® CLEAR tested by Lubrizol has been tested Advanced Materials by Spears® and is monitored on Manufacturing to an on going basis be compatible with to assure chemical Flameguard® pipe and compatibility with fittings. FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. Description Recessed Canopy Coverage Extensions provider increased coverage of the recessed canopy flange against the ceiling or wall material where it is installed. The primary purpose is to allow for increased distance between the finished surface of the building interior and the recessed sprinkler assembly. AHJs within certain earthquake zones require a minimum of 1" space between the sprinkler or sprinkler drop and the material it penetrates. Can also be used to provide coverage for oversized holes cut in finish material from previous sprinkler placements. Fits most existing recess sprinkler canopies and is compatible with all FPPI Recessed Canopys. F P P I Installation No tools are required for installation of the Recessed Canopy Coverage Extension. Simply slide the recessed escutcheon skirt through the ID of the coverage extension then install or re-install the recessed escutcheon skirt on to the retainer. Press the recessed skirt firmly into place against the interior surface the sprinkler penetrates without causing the interior surface to be moved or lifted by the recessed skirt/coverage extension. Follow sprinkler manufacturers instructions regarding the installation of sprinklers in recessed applications. May be used either horizontally or vertically. Specifications Material: .020" Cold Rolled Steel Standard finishes: Chrome White Coverage: 5" x 1 /16" ID Item Numbers: 01 -491 5" Coverage Chrome 01-493 5" Coverage White 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 0 2012 Fire Protection Products, Inc. A 131TAOI FIRE PROTECTION 9) Hydraulic Calculations 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com A615-0353 A jITAN FIRE PROTECTION THE FIELDS CHURCH 2265 CAMINO VIDA ROBLE CARLSBAD CA, 92011 MATERIAL SUBMITTAL HYDRAULIC CALCULATIONS 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com A 31TA01 FIRE PROTECTION Table of Contents Alarm Devices Sprinklers Pipe Fittings Valves Hangers Sway Bracing Accessories Hydraulic Calculations 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com A 131TAt4' FIRE PROTECTION 1) Alarm Devices 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com (E)POTTER The Symbol of Protection Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 2 1/2' DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 4" DNIOO VSR-4 1144404 5" - VSR-5 1144405 6' DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2' thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL, CIJL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38LPM)-UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.O Amps at3OVDC Resistive lOniAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV L PAGE! OF 4 3/09 (E)POTTER VSR The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. DO NOTLEA VE CO VER OFF FOR Retard Adjustment Fig. 1 ly Am ExTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0ji 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms Y TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE 7k:- POINTS IN DIRECTION OFWATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered Refer to the Compatible Pipe/installation Requirements chart for size. Correct Incorrect roa DIRECTION OF WATERFLOW ROLL PADDLE IN oPPosrrE DIRECTION OF WATERFLOW (Flawing water activates device in one direction only) DwrA 1146-It ) 50mm ADAPTER ADAPTER 20mm d2mm MAX. DNSO ONLY USE (2) 5180162 ADAPTERS As SHOWN ABOVE DWG# 1146-IF Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm mcli mm inch mm inch mm inch mon ft-lb n-rn VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25+1251-062 33.0±2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 1 3.05 0.216 1 5.49 1 0.157 4.0 0.114 2.9 2.00±125 50.8±2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 1 - - - - VSR-4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DNISO 6.625 168.3 0.134 3.40 0.280 7.11 0.197 1 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 1 0.148 3.76 0.322 8.18 0.248 1 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146 - REV L PAGE 2 OF 4 3/09 (E)POTTER The Symbol of Protection Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig.3 Break out thin section of cover when wiring both switches from one conduit entrance. ME Own 114644 Fig. 7 Mounting Dimensions 3.50 in 200 (508 234ii (59.4 mm)IJ PtPEDIA U-BOLT NUT + 5.25 in U-BOLT WA5HER" (+133.4 mm) PIPE SADDLE PIPE PLASTIC PADDLE NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR ON 50- ON 65 2-2.5 in NOMTNAL PIPE ISA. +2125 in (+54.0 NIM FOR ON 80- DII 200 3-8 in Fig. 8 GREEN GROUND VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal 0 06G. #1146-16 uninsulated section of a single conductor should not be looped and the terminal and serve as two separate connections. The e must be severed, thereby providing supervision of the nection in the event that the wire become dislodged from under terminal. Failure to sever the wire may render the device perable risking severe property damage and loss of life. not strip wire beyond 3/8" of length or expose an uninsulated ductor beyond the edge of the terminal block. When using nded wire, capture all strands under the clamping plate. Fig.5 Typical Electrical Connections BELL LPLBEL RCE 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact Notes ZONE is used to operate a local audible or visual annunciator. OR BELL A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. WATERFLOW For supervised circuits, see "Switch Terminal Connections" LR I EIO ON FIRE PANEL drawing and warning note (Fig. 4). OWe 1146.12 - Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MFG. #5401146 - REV L PAGE 3 OF 4 3/09 VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) S Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe I. Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig.6 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHINSECrIONOFCOVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING / CREWS RETARD/SWITCH ASSEMBLY VT U (2) LOCATING PINS fl DO NOT REMO (2) RETARD HOL SCREWS (2) LOCATII BOSSES 1N DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV L PAGE 4 OF 4 3/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0001 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D VSR-F VSR-SF VSR-FE-2 VS-SP VS-F VSR-SFG VSR-SFT VSG VSR VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-B WFSR-C WFSPD-B PS10 PS-1 OA PS-100A WFSR-F PS100 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterfiow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2", 2-1/2", 3", 4") and listed CPVC pipe (2", 2-1/2", 3"). Model VSR-SF for use on 1', 1-1/4", 1-1/2" and *2 steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and *2 plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 400F. Rev*5172007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4(101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at loft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 1 24VAC PBA246 1806024* .17A 91 78 24VAC PBA248 1808024* .17A 94 77 24VAC PBA2410 1810024* .17A 94 78 E 2OVAC PBA12O6 1806120* .05A 92 83 20VAC PBAI2O8 1808120* .05A 99 84 2OVAC I PBA12010 1810120* .05A 99 186 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE I OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2 conduit entrance 3 3/8" 5" 86)I27) (66) 41/4 (lOS) DWGS 776-2 (E)POTTER The Symbol of Protection Bells Dimensions Inches (mm) Fig. I BELLS PBA-AC & MBA-DC Wiring (rear view) Fig. 3 A.C. BELLS 10" (2 0) (ISO) 2 11/16" (68) DWC# 776.1 WHITE (IN) __..,, WHITE (OUT) FROM CONTROL PANEL OR CBLACK PRECEDING DELL BLACK(IN) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELYAFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. OWSI 176-I Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-I PAGE 2 OF 2 01/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0328:0119 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models*SB624153075, *5B624.75110 PBA246, PBA248, PBA2410, PBA1206, PBA1208 and PBA12010 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 6", 8" and 10". Models MBA-6, -8 and -10 bells, suitable for outdoor use when used with Model BBX-1 backbox. Refer to listee's data sheet for detailed product description and operational considerations. RATING: PBA-246,-248,-2410: 24 VAC PBA-1206, -1208, -12010: 120 VAC MBA-6, -8, -10: 12 or 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. NOTE: *Rev 5-17-2007jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 01TAtf FIRE PROTECTION 2) Sprinklers 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com FireLock® V38, K5.6 Models V3801, V3802 Adjustable Concealed Standard Spray Standard and Quick Response A V3801 and V3802 Approvals/Listings: LPCB LISTED 0832 104-la/02 See Victaulic Publication 10.01 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2713 mm adjustment to accommodate concealment needs. The 'standard" design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. 4-t-3 _U1 icf 40.50 Technical Specifications: Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: 1/2713 mm K-Factor: 5.6 Imp./8.1 S.l. Nominal Thread Size: 1/2/15 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 ictaulic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Material Specifications: Deflector: Bronze per UNS 022000 Cover Plate: Fusible solder Bulb: Glass with glycerin solution. Bulb Nominal Diameter: LI Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS 065100 Pip Cap: Bronze per UNS 065100 Spring: Stainless steel per UNS S30100 Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS 026000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene Accessories: Installation Wrench: LI Concealed: V38-4 or V38-5 Sprinkler Finishes: LI Plain Brass (only) Cover Finishes: LII Chrome Plated LI White Painted3 LI Flat Black Painted3 LII Custom Painted3 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 jtauIic' victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Approval/Listings: Approvals/Listings Model V3801 V3802 Orifice Size (inches) 1/2" 1/2" Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor SI.4 8.1 8.1 Response Standard 5mm bulb Quick' 3mm bulb Deflector Type Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings F°/C° V3801 V3802 135°F/570C 135°F/570C 1551F/681C 1551F/681C CU Lu s 1751F/791C 1751F/791C 2000F/930C 2000F/930C 155°F/68°C4 FM5 NONE 1750F/79°C4 2000F/930C4 1 35°F/57°C 1350F/570C NYC/MEA5 #62-99-E 1 550F/680C 155°F/68°C 1750F/790C 1750F/790C 200°F/930C 2001F/931C 1351F/571C 135°F/570C C5FM5 #7690-0531:112 1550F/680C 1550F/680C 175°F/790C 175°F/790C 200F/930C 2001F/931C i55F/68°C Sprinkler/1 38°F/59°C Cover 1550F/680C Sprinkler/1 38°F/59°C Cover LPCB 175°F/79°C Sprinkler/1 65°F/74°C Cover 175°F/79°C Sprinkler/1 65F/74°C Cover 200F/93°C Sprinkler/1 650F/740C Cover 200°F/93C Sprinkler/i 65F/74°C Cover 1350F/570C 135°F/57°C 1550F/680C 155017/680C VNllPO 1750F/790C 1751F/790C 200°F/930C 200°F/930C 286°F/141°C 2860F/141oC CCCf ZSTDY NONE 1550F/680C For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 X.04—c—ta—ulicf 2'/Sl mm 55/13 mm Adjustment Finished Surface Maximum Extension victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 251s/68 mm Mae Hole 2Y."/60 mm Min. Hole 2'A6"/59 MM 161~~ pical Ceiling Tile Finished Surface mm Minimum Extension Distribution Patterns: Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory ENEEMMM iuuiuuiusa iiiuiuiu uiuimuaiva uauIuaI-I. aiii•aaiu IIuIuuhIIh1iaIu u•uaauiuuii a••IuIuaNNI 2' 4' 6' 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7ps1 _... 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 4 j4tauijc. 10 3.0 m 8' 2.4 m 6' 1.8 m 4' 1.2 m 2' 0.6 m 0 victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -67°F!-550C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature - OF/OC Temperature - OF/OC Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color Identification Rating Allowed Ordinary A 135°F/570C 1 100°F/38°C Orange A6 13511 100 57 57 Ordinary C 1550F/680C 1000F/380C Red D 7 165 74 1 50 65 Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/930C 150°F/650C Green High J 286017/1410C 2250F/1 070C Blue Extra High 8 K 3600F/1820C 3000F/1490C Purple - M Open - No Bulb 6 A For use with Standard or Quick Response concealed Sprinkler 135°F/57°C or 155FI68C. D For use with Standard or Quick Response concealed Sprinkler 175°F/79°C or 200°F/93°C. 6 138°FI59C per LPCB Note custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent - V3801, V3802 V38-4 or V38-5 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 __________ victaulic.com I Sprinkler I FireLock5 I K5.6, V38 I Publication 40.50 : ____ Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this 1 ME 0 L product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. . Installation Note Reference should always be made to the -100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in PDF format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Zero-Flex are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 jscCtauuic. FireLock® V27, K5.6 4_t: uhcr Models V2703, V2707, V2704, V2708 40.10 Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm - p5d K Factor: 5.6 Imp./8.1 S.l.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) V2703/V2704 V2707/V2708 V2707/V2708 • 250 psi/1725 kPa (UL) Upright Pendent Recessed Pendent Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Approvals/Listings: Mm. Operating Pressure: K::::: 11111 @' EI LIJ • 7 psi/48 kPa 0786 • 0.35 bar/5 psi (VdS for upright only) See Victaulic Publication 10.01 for more details. Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see H. chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. j updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 ic_tau Iic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS 011000 Pendent Deflector: Bronze per UNS 051000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm LII Quick Response: 3.0 mm Load Screw: Bronze per UNS 065100 Pip Cap: Bronze per UNS 065100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: El Open End: V27 LII Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated LII White painted3 LI Black painted3 LI Custom painted3 LI Proprietary Nickel Teflon2 coating3 LI VC-2504 155, 200, 286 SR Only: LI] Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 ',,4tauiic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135"F/57°C 135°F/57°C 135°F/57"C 135°F/570C 135"F/57°C 1550F/680C 155°F/680C 155"F/68"C 1550F/680C 1550F/68°C 135"F/57°C cULus 175°F/790C 175"F/79°C 175°F/79°C 1750F/790C 175°F/79°C 155°F/68°C 200°F/93°C 200"F/93°C 200"F/930C 200°F/93°C 200"F/930C 175°F/79"C 286"F/141"C 286°F/141°C 286°F/141"C 286"F/141"C 2860F/141°C 200°F/930C 360°F/1820C 360"F/182°C 135"F/57°C 1350F/570C 135"F/57"C 135"F/57"C 155°F/680C 1550F/68°C 135"F/57°C 1550F/680C 1550F/68°C 135"F/57"C FM 1750F/79°C 175°F/790C 155°F/680C 175°F/790C 175"F/79°C 155"F/68°C 200"F/93°C 200" F/93"C 175°F/790C 200"F/93°C 200"F/93°C 175"F/79"C 286"F/141°C 286"F/141"C 200°F/930C 286"F/141°C 286"F/141°C 200°F/93"C 360"F/1820C 360"F/182 C " 1350F/570C 1350F/570C 135"F/57"C 1350F/570C 1350F/570C 155°F/68"C 155"F/68°C 1550F/680C 1550F/680C 155"F/68"C 135°F/57°C NYC/MEA 62-99-E 1750F/79°C 175°F/79"C 1750F/790C 1750F/790C 175°F/790C 155"F/68"C 200°F/93"C 200"F/93"C 200"F/93°C 200°F/93"C 200°F/930C 175°F/79°C 2860F/1410C 286"F/141°C 286"F/141°C 286°F/141"C 286"F/1410C 200°F/93"C 360°F/1820C 360"F/182"C 135°F/570C 135"F/57°C 135"F/57°C 135"F/57"C 135"F/57"C 1550F/68°C 155°F/68°C 155"F/68°C 1550F/68°C 155°F/68°C 135"F/57"C CSFM 7690-0531:112 175°F/79"C 1750F/79"C 175"F/79"C 175°F/79°C 175°F/79°C 155"F/68°C 200"F/93°C 200"F/930C 200°F/93°C 200°F/93"C 200"F/93"C 175°F/79"C 2860F/141°C 2860F/1411C 286°F/141°C 286"F/1410C 286"F/141"C 200"F/93"C 360°F/182"C 360"F/182°C 135°F/57"C 1550F/68°C 1350F/570C LPCB 175°F/79 °C None None 1550F/680C None None 200°F/930C 1750F/79"C 286"F/141"C 200°F/930C 135"F/57"C 135"F/57°C 1350F/570C 1350F/57°C 1550F/680C 155°F/680C 1350F/57"C 155"F/68"C 155"F/68"C 135"F/570C VNIIPO 1750F/790C 1750F/790C 155"F/68"C 175°F/79°C 175°F/79°C 155"F/68°C 200°F/93°C 200°F/93°C 175°F/79"C 200"F/93"C 2 00"F/93"C 175°F/790C 286°F/141"C 286"F/141"C 200°F/930C 2 860F/141°C 286"F/141°C 200°F/93°C 360"F/182°C 360"F/182"C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 1550F/680C 1550F/680C None 155°F/680C 1550F/680C None 200°F/930C 200°F/930C 200°F/930C 200" F/93"C 135"F/57°C 155"F/68"C 175"F/79 "C 155°F/68"C VdS 200"F/930C None None 1750F/79°C None None 286"F/1410C 200°F/93°C 360"F/182"C 86"F/141"C 2 135°F/57°C 135" F/57"C 155°F/68°C 155°F/68°C CE 175°F/79°C None None 175"F/790C None None 200"F/93"C 200"F/93"C 2860F/1410C 286"F/141°C 360"F/182"C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 'js(taUIiC 37 mm 2 60 134/ 234/ 41 mm 60 mm victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 xx /bU mm Max. Hole 2/51 mm Min. Hole Om Typical Ceiling Tile 131a"/ 151o7 43mm Finished Surface 30rm ____________________ MAXIMUM RECESS 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 24mm I MIME lI1 75 mm MAXIMUM EXTENSION 3%" Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 \J'taUIiC victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory FF1111111_L 1 iI 2' 4' 6' 8' 10 12' 14' 0.6mn 1.5mm 1.8m 24m 30m 3,5mm 4.3mm Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory .II..uIIuI.I NOME MONOMMM MMMMM i•uuuuiimu mmmm ~Mmmmmm MMM uii•u•iaiuui Iauuaiaau•uuiiiui•uiau 2' 4' 6' 8' 10 12' 14' 16' 0.6n 1.2rn 1.8n 44n 3.0n 3.7n 4.3m 49m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 5 A—C.—taul—id 8' 2.4n 6' 1.8. 4' 1.2m 2' Iff 30 8' 2.4m 6' 4. 1.2n 2' 0.6m 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F157°C 100°F/38°C Orange Ordinary C 155°F/68°C 100°F/38°C Red Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/93°C 150°F/650C Green High J 286°F/141°C 225°F8/107°C Blue Extra High 7 K 360°F/182°C 300°F/149°C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703, V2704 Upright Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. iL 0 W Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Skeet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in PDF format on our website at victaulic.com. equipment without entice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. i updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 ___________ FireLock® V27, K5.6 Models V2709,V2710 Standard Spray Horizontal and Recessed Horizontal Sidewall Standard and Quick Response V2709/V2710 V27091V2710 Standard Horizontal Recessed Horizontal Sidewall Sidewall Approvals/Listings: USTED @® See Victaulic Publication 1001 for more details. Product Description: These Model V27, standard spray horizontal sidewall sprinklers are designed for up to ordinary Hazard per NFPA 13, and can be used for standard or recessed installations. The design provides a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to I4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Job/Owner 4tauIicr 40.11 Technical Specifications: Models: V2709, V2710 Style: Horizontal Sidewall or Recessed Horizontal Sidewall Nominal Orifice Size: 1/2 I13 mm K Factor: 5.6 Imp./8.1 S.l.' Nominal Thread Size: 1/2 /15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. 1 JtaU —Ii cr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Material Specifications: Accessories Horizontal Deflector: Commercial bronze per UNS C22000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Standard: 5.0 mm LI Quick Response: 3.0 mm Load Screw: Low Silicon bronze per UNS C65100 Pip Cap: Low Silicon bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: LI Open End: V27 LI Recessed: V27-2 Sprinkler Finishes: El Plain Brass LI Chrome plated LI White painted3 LI Flat black painted3 LI Custom painted3 LI Proprietary Nickel/Teflon2 coating3 LI VC-2504 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. NOTE: Weather resistant recessed escutcheon available upon request. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 jtauIiC victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Approvals/Listings: Model ________________ ________________ APPROVALS/LISTINGS V2709 V2709 Recessed V2710 V2710 Recessed V2710 Recessed Orifice Size (inches) 1/2' 1/2' 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick Quick Recessed Recessed Recessed Deflector Type Horizontal Horizontal Horizontal Horizontal Horizontal Sidewall Sidewall" Sidewall Sidewall (up to Sidewall (up to ½" adjustment) 3/4" adjustment) Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 135"F/57'C 155°F/68°C 135°F/57°C 135°F/57°C cuLus 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 2OOF/93°C 175"F/79°C 200°F/93°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 286°F/141°C 200°F/93°C 200°F/93°C 360'F/182"C 135°F/57C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57"C FM 6 175°F/79°C 155"F/68"C 175°F/79°c 155°F/68°C None 200°F/93°C 175°F/79"C 200°F/93°C 175F/79°C 286°F/141°C 200°F/93°C 286°F/141°C 200°F/93C 360°F/182°C 135°F/57°C 135F/57'C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C 135F/57C NYC/MEA 6 #62-99-E 175"F/79"C 155°F/68°C 175°F/79°C 155°F/68°C 155'F/68°C 200°F/93°C 175°F/79°C 200°F/93°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 286°F/141°C 200°F/93°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 135F/57°C 135°F/57°C CSFM6 #7690-0531:112 175°F/79°C 155"F/68°C 155" F/68°C 175"F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79"C 200°F/93"C 175°F/79°C 175°F/79"C 286°F/141°C 200°F/93°C 286° F/141 "C 200"F/93"C 200°F/93°C 360°F/182°C 135°F/57°C 155°F/68°C 155 F/68 C 135° ° F/57° ° C LPCB 6 104b/01 175°F/79°C None 175°F/79°C None None 6 104b/02 200°F/93°C 200°F/93°C 286°F/141°C 86° F/141 "C 2 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C None 200°F/93°C 175°F/79°C 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 286° F/141 "C 200°F/93°C 360°F/182°C CCCf ZSTBS None None None None 155°F/68°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 6 Light Hazard ONLY Note: Listings and Approvals as of printing. All are approved open. 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 3 \J$'t _au UIc victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Dimensions: 3789 mm H- 57 mm 8mrn ]I 11 mm 32 mm Standard HSW — V2709, V2710 11/16/ 23/16 17mm 1/16,Z.-411/165 56mm I43mm 30mm Finished Ceiling I \- Finished Ceiling 4- l2 Per NFP ?5nnm 4- l2 3f5mm ' NFPA 2/51 mm 23/8/80 mm 2751 rn 2 3/ 60 mm Max. 215/16 Mm. I/ole / Mm. Hole ManHole Finished Surface -' Finished Surface-" —1 t—lypicalWall —4 I.. Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS ½ Adjustment Recessed — V2709, V2710 (drawing not to scale) 15/167 24mm 9/16/58 mrrr r 53nmm r7/ '- Fodshed ceiling I 4-12/102-305mm _j ,,J 4-I 2/102 - 305 mm Per NFPA FL.'I PerNFPA Finished Ceiling in 'ole 215/167 H.le 75 mm Min. Hole Max. Hole Finish 7 M ed 23/8/68 rues FeohedSmfecn 23/8/60mm urface Typical Wall ._1 I.-. Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 3/4"Adjustment Recessed — V2709, V2710 (drawing not to scale) 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 A_________ LiIIIIIIKIiLTI 10' Dl- 3.0 m 8' 2.4 m 1.8m 4, 1.2m 0,6 m 7psi 48 kPa 15 psi 103 kPa 30p51 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Distribution Patterns: Models V2709, V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns - Trajectory 0 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0,6 m 1,2w 1,8 m 2.4 m 3.0w 3.7 m 4.3 m 4.9 m 5.5 m 6.1 m 6.7 m 7.3 m 7.9 m Models V2709, V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns - Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2.4m 3,0m 3.7m 43m 4.9m 55m 6.1 m 6.7m 7.3m 7.9m 8.5m 0. OEC ''-t•'i•t-- 317 m t 8. 2 rt 4m 16' 4.9 m m NOTES: Data shown is approximate and can vary due to differences in installation, These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 JtauIicr 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - °F/°C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F/57°C 100°F/381C Orange Ordinary C 155°F/68°C 100°F/38°C Red Intermediate E 175°F179°C 150°F165°C Yellow Intermediate F 200°F/93°C 150°F165°C Green High J 286°F/141°C 225°F1107°C Blue Extra High K 360°F11 82°C 300°1 Purple - M Open - No Bulb Standard response only. V27-2 Recessed V27 Open End No escutcheon With escutcheon Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Skeet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in POE format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.11 2545 Rev. j updated 07/2014 © 2014 Victuulic Company. All rights reserved. taiii victaulic.com 6 A I TAt4 FIRE PROTECTION 3) Pipes 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com LtHT'i co 'all co 4.!l p c®us LISTED APPROVED COO 4 0 NMA Aatfc.n pit. NFPA 2 D. ull Moose Tube® is a customer focused, o growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 BULL. MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. cus LISTED <s> APPROVED I] L4#FIA NFPA" souon ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASIM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information conintd htrein is accurate as known at the time of pgIcotiop, Bull Moose Tubee reserves the right to change product specifications without notice and without incurring obligation. Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube" made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. r c®us LISTED <N> IAPPROVED [;] 0 NM NFPA 21 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 TT f660 1 '1'12 991 jfl 1 TIiffjE 2 T 1.900 1.682 7.76 2.09 lbs/ft :r 3.053 r Gi 2 2375 i2157 627 264Ib5/ftr 4223 37 21/2 2875 - 2635 492 353 lbs/ft 5893 -- 3 ' 3500 ] 3260 354 434Ibs/ft ) 7957 '19 4 - 'i'flo 4.260 2.50 - 5.G2lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. - - WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT - WEIGHT SIZE 1 1.315 - 1.049 -, . 1.00 1.68 lbs/ft , 2.055 70 11/4 1660 'T1RRO "iOO '2271bs/ft - 2.918 1 51 1-1/2 1.-906- 1.610 100 2.72 lbs/ft 3.602 44 - 2 2375 -- 2067 100 66 lbs/ft 114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 - 3. 00 068 100 - [-7—.5alb./ft 1[T 1Q7c 19 = 4* .'T 4.500 4.026 - 1.00 - 10.80 lbs/ft [ - 16.316 , 19 *Only available in Casa Grande, AZ **corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, D( Masur OH BULL NIODSE TUBE COIVIPANY 63 017 Bull Moose Tube's® Eddythread 40® is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of 1. ADVANTAGES OF BULL MOOSE TUBE® EDDYTHREAD 40® Has a Corrosion Resistance Ratio of 1.0. Has a pressure rating of 300 psi. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDYTHREAO 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1 1.295 - 1.083 - 1.00 1.461 1.860 70 11/4 flTh65O - 1418 i00] 2070 - 2754 - si 1 1I2 1900 1.654 1.00 2.547 3.468 44 3° *Corrosion Resistance Ratio per latest UL Directory Listing CUS LISTED <> APPROVED I;] ONM NFPAS PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call (800) 882 4666 sales@bullrnoosetube corn 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH BULL NICOSE TUBE CDEpANV 63017 5 Bull Moose Tube's® Eddylitell is a lightwall threadable pipe manufactured in NPS 1 " through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements ofASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection system!, with a woikiny pressure of 300 psi or less. c®us LISTED <9> APPROVED C;] z NFSA NFPA" 6 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 f1/4Ti b6() I4U4 [ iiT4 I 617 2_364 61 - 1-1/2 1.900 1.712 .O.12 4.53 1.967 2.965 61 -- ]' '375 fl 21/I iLJ [ U-H -17 Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. , , D For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas,D( Masur OH BULL MOOSE TUBE COIVTRAflIV 63017 LISTED <19> 1 APPROVED Do oh7%4 NFPA" ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MIC preventative coating. NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. WT. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 11/2 1900 1728 344 1.844 2860 61 2 2.375 2.203 2.78 - 2.330 3.982 - 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3500 - 3.334 —1.00— - L —3- 361 7144 19 4 - 4500 4310 100 L - 4968 4r ii 290 _ 19 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call (800) 882-4666 sales@builmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury OH BULL p.'IOOSLTUBECDIVIRAI'.W 63017 7 Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I) a versatile product that can be Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE • (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.20111 2.17 .868 1.359 91 r 1 i,i 1 u 1r 546 140 - 1107 1 920 61 11/2 1900 1786 111 1274 2360 61 2.375 JL - 2.261 1.00 . 1.604 - - 3.344 - - 37 * Pressfit is Registered Trademark of victaulic Company of America ** Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas,D( Masury, OH BULL IVIDOBE TUBE CD,VA,, 63017 LISTED APPROVED C;]. Aw~. NFPA 8 NPS(IN) 1 1-1/4 1-112 2 2-1/2 c®us LISTED APPROVED (]ONFM NFPA L O.D.(in) J 1.315 1.660 :. 1.900 2.375 C I.D.(in)F 1.201 1.546 1.786 2.261 .. - ULTRA EDDY® 0868 1.101 1274 1604 aterFiIighTOb/ft 1.359 - 1920 -3344- ] 217 140 1-.660-- C. - 11 -1'.06- [ 1 900 2 375 - 2.875 3500 4.500 '1530 1728 2203 2.705 - 3334 flHDOn) 1 - 1.222 [1844 -4-.9-Em 68 2330 2809 3361 EDDY FLOW® E 2019 2860 3982 - 5299 - 7.144 11290 ____ water Filled WhUb/ftjJ CR R r 1315 1.98 1660 j 44 2 1900 2375 78 166 2875 100 3500 f00 4500 0D (in) -- ID (in) -1.097 1 442 1 682 2157 2.635 3.260 4.260 SCHEDULE EmptyWeight(Ib/ft 1.410- 1 810 4.340 5 620 10 WaterHlWeight(lbIft)] 18202518 3053 4223 5.893 7.957 11.796 127 991 776 627 492 354 250 - On) 1315 1660 ID_ (in) 1.137 1.482 1.712 2177 -- - EDDYLITE EmpWeigt(Ib/ft 1260 L_117 1 1967 2,617 - 2965 4230 _013 008 012 0.16 öbOnJ 1.295 1.650 1.900 2.375 - 1083 1418 1645 2.123 1 L_fon)__J EDDYTH READ EmpWeig_tQh/ft)'Th 461 -2070 2.547 - 3.308 - 2.754 3.468 4.842 iterRIledWeightft1860. C.R.R. 1.00 1315 1.00 1.660 1.00 1.00 1900 2375 [_2875 ]_3500 4500 I 0D (in) 1 049 1380 1_610 2_067L_2469 3_068 -'4.026 ID_(in)- SCHEDULE 1.68U IF 7 - - 3 660 r 000 1 7 siö EE (lb/ftr 40 1 3.602 5.114 7O75 = 10.783 16.316 I"C.R.R.]1.00j1.00r1.00 ---i:-or ---i 1.00 1.00 For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com A A Or From Canada Call (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road J Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masur OH BULL IVIDOSE 1UBL COIVIPAI%W 63017 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE c®us LISTED APPROVED com] A,NONFSA Amedcal pie. NFPA 1 It ULTRA EDDY- 0.868 91 1410 91 1260 91 1461 70 1680 70" 1107 61 1222 61 ( 1810 J 61 2.070 ' 51 2 io 51 -1274- 61 1844 61 2.090 61 1967 61 25471 - 44 2720 [44 1.604 ] 37 2330 ][ 4piE 2.617 37 _308 30 3GGo1r 30 2.899 3 530 30 - 5800 3.361 4340 19 7580 4968 19 10800 9289ii 10 - 16.940 7 1,659 2695 3079 fl2408 2148 2470 r 1418 - 1 565 2319 2650 - 2,071 - - - 2,217 -, - 2,43 1 1,632 2362 2,677 2 520 2353 2513 1,246 - 1,810 2,051 - 2,033 2,084 1i 2J06 j 1,770 2,224 - - 3 654 ] r 134111533 1 732 1' 3,024 jr i982 2265 2,242 4309 195i] 2,490 1,896 2752 2454 2822 1621 1789 2,367- 2534 2,778 1,865 2700 3,060 2880 2690 2872 1,424 2069 2,344 2,324 2,382 2635 2,022 2,542 4176 1 979 4925 2229 2,846 3456 3601 2563 267O 1,975 3208 - 2867 - - 2557 - - 2,940 1,688 I 84 2760 2466 - 26i9' 2,894 1,943 2812 3,187 3060 2802 - 2992 1,484 2,155 2,442 2,421 248l - 2745 2,107 2,648 - 4,350 1596 -- 2,062 2360 ' 5130 TT - 2,965 IE HE -D!I0 I1 IIDYLIEfl II EDDHREAD4O] SCHEDULE 40 11/4 It ULTRAEDDYfl FL0 EDDYW1 IIISCHEDULE 10 IL IL EDDYTHREAD4Q1 SLHED1JLE4u_J 1 1/2 P ULTRA EDDY®Jj L EDDYFL0W1 ScHEDULE1O]' EDDYLITEJ' HREAD4 EflThuLE4011 1D1ThAEDDI 2 EDDY FL01 LJDUTE 'J. LPDHREAD1O]. EsaIuLc4oj 2-1/2 LY±L07Wi L SCHEDULE 10_J CHEDU PSLE 40J r EDDY FLOW] 3 L - L.SCHEDULE iiiIL SCHEDULE40L EDDYFL0W 4 LCHEDULE10 S CHEDULE40JL r SCHEDULE1ölij 6 SCHEDULE 10 1 10 * Only Available in Casa Grande, AZ. BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 1/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 1 809 1 648 1 531 455 381 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40~~4O 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 1 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 1 1/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED APPROVED I] LA fA NFPA For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ BULL IVIDSL TUBE CO,*,AJ%IV 63017 www.bullmoosetube.com sales@bullmoosetube.com Dallas,D( Masury, OH 11 A JD ITAt4 FIRE PROTECTION 4) Fittings 2880 Scott St. Suite 105. Vista, CA. 92081. (P) 760-295-3436 (F) 760-295-3437 Lic. No. C16-989280 www.titanfpinc.com .11 Juctile iron Threaded: Fittinc I•. r ilir