HomeMy WebLinkAbout3103 SIMBA WAY; ; FPR2017-0130; PermitPERMIT REPORT (r,city of Carlsbad Print Date: 05/27/2021 Job Address: 3103 SIMBA WAY, CARLSBAD, CA Permit Type: FIRE-Construction Residential Work Class: Parcel #: 1670404600 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Multifamily Fire Alarm Permit No: FPR2017-0130 Status: Closed - Finaled Applied: 04/21/2017 Issued: 07/26/2017 Finaled Close Out: 04/12/2021 Inspector: Final Inspection: Project Title: Description: REPLACE FIRE ALARM PANEL FROM DISCONTINUED TYPE - BLUE SAGE AT THE PRESERVE - SPRINKLER MONITORING BLDG 1 BUILDING 1 INCLUDES: UNIT 1-3103SlMBAWAY UNIT 2-31O5SIMBAWAY UNIT 3-31O7SIMBAWAY Applicant: FPContractor: HCI SYSTEMS INC HCI SYSTEMS INC JOHN LEO 4585 MURPHY CANYON RD 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 SAN DIEGO, CA 92123-4318 (909) 628-7773 (858) 560-7000 FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $136.00 FIRE Sprinkler Monitoring $371.00 Total Fees: $507.00 Total Payments To Date: $507.00 Balance Due: $0.00 Fire Department Page _1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov HC1 Systems Inc FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Sprinkler Monitoring System Complete Material Submittal Prepared for: Ll BLUE SAGE AT THE PRESERVE Haymar Drive./College Blvd., Carlsbad, CA 92008 FPR20I7-0130 3103 SIMBA WAY REPLACE FIRE ALARM PANEL FROM DISCONTINUED TYPE BLUE SAGE AT THE PRESERVE - SPRINKLER MONITORING BLDG 1 BUILDING 1 INCLUDES: 1670404600 10/30/2018 FPR20I7-0130 4585 Murphy Canyon Road, San Diego, CA 92123 Phone: (858) 560-7000 FAX: (858) 560-7007 Website: www.hcisystems.net BLUE SAGE AT THE PRESERVE Haymar Drive/College Blvd., Carlsbad, CA 92008 Manufacturer Device Model # Description C.S.F.M. # KIDDE FX-5RD Fire Alarm Control Panel 7165-1657:0102 Include With: INTERSTATE SLA-1079 12VDC 7 Amp-Hour Sealed Lead Acid Battery U.L. Listed TELGUARD TG-7F$ Cellular Dialer 7300-1402:0109 EST 511C Photoelectric Smoke Detector 7272-1657:0277 Ol 0 4 nited Technologies Small Building Fire Alarm Solutions Technology that saves lives Conventional Fire Alarm Systems FX-1ORD, FX-1 OR, (FX-5RD FX-5R QY * FDNY COA 6230 Overview Kidde brand conventional fire alarm systems consist of 5 and is 10 zone fire alarm control panels (FACP), an optional integrated upload/download DACT (dialer), intelligent/analog type detector features, serial annunciator modules, and serial remote relay mod- ules. All FACPs and components are Listed to the 10th edition of the ANSI/UL 864 standard and CSFM/FDNY approved. Standard Features Available in 5 and 10 zone (IDC) models CleanMe® feature provides remote annunciation of a dirty detector Automatic drift compensation with select detectors reduces false alarms and extends dust life Listed to ANSl/UL 864 10th Edition These systems incorporate features designed to simplify installation, operation and maintenance, including front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with CleanMe® -compatible smoke detectors, these con- trol panels provide intelligent type features such as remote mainte- nance alert and automatic drift compensation that significantly reduce the chance of a false alarm and simplify maintenance calls. Models with fully integrated upload/download DACT enables PC programming Zone or NAC pairs convertible to single Class A circuits Combination Waterfiow and Supervisory lDCs NACs programmable by zone and individually selectable for notification appliances, continuous, temporal outputs, or coded Front panel programmable simplifies installation and servicing Precision synchronization with compatible notification appli- ances and optional audible silence over two wires On-board relays for Alarm, Supervisory and Trouble Optional serial bus relay modules are programmable for Com- mon, Zone, or Matrix activation Optional serial bus remote annunciator family One person walk-test (audible or silent) Optional City Tie and Reverse Polarity Modules Trim ring available for semi-flush mounting Kidde systems are powerful enough to meet the demands of today's life safety installations while leaving plenty of room to grow in the future. They support Class A operation by combining pairs of on-board lDCs or NACs to provide the necessary Class A circuits. For example, the FX-10RD comes factory set to support 10 Class B lDCs and 4 NACs. But it can be field-configured to provide 5 Class A lDCs (no Class B lDC's), and 2 Class A NACs - or any other com- bination of circuits that fall within the circuit-pairing parameters. FX-IOR(D) FX-5R(D) Class BlDCs UptolO Upto5 - Class A lDCs Up to 5 Up to 2 Class BNACs Upto4 Upto2 Class A NACs Up to 2 1 NAC Power - - 7.0 amps 3.5 amps Auxiliary power 0.5 amps 0.5amps Notes: Class A operation will reduce the number of available Class B lDCs and/or NACs, 0 depending on the panel configuration. See Specifications for details. Page 1 of 8 K85005-0126 Issue 2.2 Application Kidde conventional fire alarm systems provide smoke and fire de- tection, occupant notification and off-premises signaling for small- to medium-sized buildings. Each IDC can be configured for either Class B or Class A opera- tion and one of eight operating modes: Alarm —with or without smoke detector verification including discrimination of contact devices Waterflow Alarm; Waterflow Alarm/Supervisory (Combination IDC); Supervisory (Latching/non-latching); Monitor (non alarm or supervisory) Signal Silence Drill Cross zoning NACs may also be configured for either Class B or Class A operation. Additionally, NACs can be individually configured for one of six outputs. These are Genesis, Genesis (AN silenceable) Continuous, Temporal, Coded, and City Tie. The Genesis selec- tion allows independent horn control over two wires and provides precision synchronization of notification appliances, all without the need for a signal master accessory. When configured for compatible notification appliances, the Alarm Silence function will silence connected audible appliances but strobes will remain active until the panel is reset. When Genesis Mode is selected, both the horns and strobes on compatible notifi- cation appliances will be synchronized across all NACs. Note: Zones may be selected for either latching or non-latching operation. Always check with your AHJ regarding approvel of silencing audible while leaving strobes flashing. Detectors with intelligent features at a conventional price When combined CleanMe® -compatible smoke detectors, Kidde systems provide intel- ligent features at a conventional price. If a CleanMe® detector drifts out of the UL sensitivity range, Kidde's patented remote maintenance reporting sends an alert to the control panel. This feature reduces the chance of a false alarm and simplifies service calls. In addition, CleanMe -compatible smoke detectors have built-in drift compensation that extends the time between cleanings. If cleaning is ever necessary, it is literally a snap with the Kidde exclusive replaceable optical chamber. For a complete list of CleanMe® compatible smoke detectors, visit http.-IlKidde-flre.com. Panel LED Display The following system LEDs display the panel's status: Alarm - panel is in the alarm state; Trouble - panel is in the trouble state; Supervisory - panel is in the supervisory state; Power - indicates the status of the AC power source; Disable - indicates when any IDC, NAC, relay or the DACT is disabled; Annunciator Trouble - indicates trouble on the remote an- nunciator bus; Battery Trouble - indicates battery or charging problems; Ground Fault - indicates a short between any panel circuit and ground; Walk Test - indicates that one or more lDCs are in the walk test mode; Alarms Silenced - indicates that the panel is in the alarm state with one or more NACs silenced. Waterfiow - indicates that one or more circuits have detected an active waterfiow switch. Service Detector - indicates the presence of a dirty detector with CleanMe® compatible ESL smoke detectors. Remote Disconnect - indicates off site communication has been disabled. Each IDC has a disable switch and three LEDs: Alarm - red - indicates tiat the IDC is in the alarm state; Trouble - yellow - indicates that the IDC is in the trouble state or is disabled (when flashing); Supervisory/Monitor - yellow - indicates that the IDC is in the supervisory state or the monitor state (when flashing). Each NAC also has a disable switch and a trouble/disable LED. Status indication with the DACT/Dialer installed The optional upload/download dialer's LCD display provides two lines x 16 characters of text. For programming, the top line displays the programming step and the lower line displays the selected option. All system events are displayed on the LCD with custom zone messages. Dung normal operation, the LCD will display any off-normal condition present in the panel. lP and Cellular Communications Several popular third-party IF/Cellular communicators have been tested with the FX conventional control panels and are compatibil- ity listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the FX con- ventional control panel compatibility documentation part number 3101019-EN for a full list of compatible communicators. S S Page 2ot8 DATA SHEET K85005-0126 i4ct to t for flst Ititloo ç r. Issue 2.2 S The Remote Relay Module mounts on a plastic track inside an MFC-A cabinet. cl-p Uptotwo Ifl-... RRM24s can be II IF_J mounted in an Ii FSRRM-Sllsnap track Up to two I FSRRM-S11s can be mounted in an Snap track M MFC-A Options Off-premise communication A fully integrated upload/download dialer is available for reporting events to a monitoring facility. The DACT also supports uploading or downloading of system configuration, status and event history. The DACT is programmable for either single or dual line opera- tion. It also supports split and dual reporting for two digital alarm receivers. The DACT brings additional features to the panel including a 32-character alphanumeric LCD display, local or remote PC pro- gramming and an event history log. Remote Annunciators and Relays The serial bus standard on Kidde conventional control panels is another installation time-saver. This circuit allows the connection of Remote System Indicators (FSRSI), Remote Zone Indicators (FSRZI- A, FSRZI-SA) and Remote Relay Modules (FSRRM24) over a four- wire (data and power) circuit. Annunciator and relay modules can be installed up to 1,000 feet from the panel on 18-gauge wire. Modules are also available for City Tie (CTM) and Reverse Polarity (RPM) connections. Power Connections N 4L Cabinet . Main AC 0 wiring block From 120 Vac, 15 A, 60 Hz Dedicated branch circuit and fuse holder Fuse 11 Dual transformer ° AC wiring block N2 4- 12 ee N L o 0 Main Tie wrap Main controller mounts transformer board TB1 o 0 C 0 0 ,0 ®" o Mounting I studs connector Upload/Download DACT/Dialer Remote Relay Module The DACT/Dialer Installs be- hind the front panel display. S The built-in DACT/Dialer is a multifunc- tion module that provides communi- cations, modem capability, and LCD display functions. Its primary function is as a Digital Alarm Communica- tor Transmifter (DACT). As a DACT, it transmits event messages to a Digital Alarm Communicator Receiver (DACR) at a monitoring facility. The monitoring facility then notifies the fire department and other responsible parties of the event. Programmable options include split or dual reporting to two DACRs. The DACT module can also be used as a modem to connect the panel to both local and remote computers for uploading and downloading of con- figuration data (programming), panel status and event history. For security, the modem can be configured to ac- cept programming on incoming calls or it can be required to call a prepro- grammed number before accepting downloads and sending uploads. The Remote Relay Module (FSRRM24) is one feature of the system that sets these systems apart from other panels in their class. This module has five Form C relays rated at 1 amp each. It can be configured to function in either a zone relay mode or a common system mode. When configured in the zone relay mode, relays energize when the as- sociated IDC is active. The module can be configured for activation by lDCs 1 through 5 or IDCs 6 through 10. One relay is automatically associated with each IDC. When configured in the common system mode, relays energize or de-energize when the panel changes edofce ('tno rQl0I ic osicilhlm IDII r.Al 1 J rI Note: All panel versions The DACT module can be configured are available with factory to work as all of the above, or as only installed DACT See order an LCD display or LCD display and table for ordering informa- tion. modem. F,onnoonnnel pane l onprevious device To next device ..._.. S..,. . for each of the following co,nntvnlcescnlne)-1 —__+coxcconi ceuonevi. connnnvnicxoen in. >_l —~ contntvniceen one functions: Alarm, Supervi- I I sory, Trouble, Power Loss, Monitor. The FSRRM24 mounts on a plastic snap track and can be installed in an MFC-A enclosure. The panel will support two RRMs of each configuration for a total of six on the 10-zone panel. Page 3 of 8 K85005-01 26 no Issue 2.2 FSRA10, FSRA1OC Wiring From control panel or 24VDC supply From control panel Ill lll rl•lIuU lull Ill Ill 11111 1111,10 F1 IN I!u 24V 24V To next remote module C C ON: Group 1 OFF: Group 2 Remote Annunciators This family of systems has several remote annunciation options. The serial __1.._.-J Pa tible electrical box remote annunciator bus can be run up to 1000 feet (305 m) on urrwisted non-shielded 18-gauge cable. Several annunciator models round out the family to provide a range of features and functions. As many as three an- - — nunciator modules may be mounted in a standard electrical box, siaring an attractive trim plate that blends with any decor. The FSRSI can be installed alone or with one or more FSRZI-As. These are available in one, two or three gang models. Each panel The FSRSI and FSRZI-A require trim plates (ordered separately). will support two FSRSls. -. Remote System Indicator Remote Zone Indicator r (FSRSI) (FSRZI-A) The FSRSI is ideal for The FSRZI-A is used to common system annuncia- indicate zones in the alarm ti: tion. It includes five LEDs — state. It contain five red and a local silenceAamp LEDs. Depending on the - test switch. The LEDs mdi- — jumper setting selected, cate power status, alarm, .----------- the LEDs will indicate either supervisory, trouble and >......, lDCs 1 through 5 or lDCs 6 ground fault. The silence I >—, I through 10. The panel can —' switch will silence the °"° >-i I I support two modules pro- onboard trouble sounder grammed for each selection. if active. The switch can °°"°'°° UT also be used to initiate a 4V IN lamp test of the LEDs on Lj0 all connected FSRSls and FSRZI-As. L4 ,. To 100 dm1,, __ I L) Remote Zone Indicator (FSRZI-SA) The FSRZI-SA indicates zones in the Alarm or Su- pervisory state. It contains FE-i- five red and yellow LEDs for Common, Zone, or Matrix activation. Depending on the > jumper setting, the LEDs will couo.aono. >-i indicate either lDCs 1- 5 or 6 I -10. The panel supports two 1IIj modules for each selection, and can be jumper selected IN to provide Alarm or Supervi- vol. COOT * - sory indications. P00000* P00,1*04- Colhlmu001io., out To 000 40*00, toneodeolce S FSRA10, FSRAIOC Remote LED annunciators The FSRA10 is a remote annunciator with capacity for up to ten zones. It includes ten bi-color LEDs (red/yellow) for indicat- ing active zones, and ten yellow LEDs for indicating zone troubles. The (C) option adds common control switches. Both ver- sions mount to standard North American 4-inch square electrical boxes. A surface box is also available. Works only with 10 zone panel. FSUIM Graphic Driver/In-:erface The FSUIM is a universai interface module that can be used by to drive graphic annunciators. It also allows control panels to control, or be controled by, other control panels. The FSUIM provides five supervised switch inputs and nine dy contact relay outputs. Nine LEDs provide visual confirmation when each relay is energized. The FSUIM is shipped with a plastic snap track for mounting in an MFC-A enclosure. Note. From control Pt or 24VDC p 000000000 I 171171 00 0,0-4,00 too. T. 1 From control panel or2tVDCpowerL SUPPlY I J nm 1n. ote module From Icy - - - Cv control panel Lc -I- - - - - C H - -4.7 It EOUR Page 4of8 DATA SHEET K850050126 Not to be utled for Installation Issue 2.2 11 Remote Annunciator Specifications General Agency Listings I UL864 (S3000), ULC, CSFM, FDNY Remote Annunciators FSRSI Remote System Indicator FSRZI-AIFSRZI-SA Remote Zone Indicator Maximum per System All panels: 2 10 zone panel: 4 5 zone panel: 2 Current Requirements Standby: 17 mA Alarm: 56 mA Standby: 8 mA Alarm 76 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Mounting ANSI/NEMA OS1 -1996 1-3 gang electrical box Operating Environment I Temperature: 32- 120° F (0- 49° C); Humidity: 93% RH, non-condensing Remote Relay Module - FSRRM24 Configured for Zone Mode Configured for Common Mode Maximum per system 10 zone panel: 4; 5 zone panel: 2 All panels: 2 Current Requirements Standby: 10 mA; Alarm: 70 mA Standby: 26 mA; Alarm: 70 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Contact Rating 1 A@ 30 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Mounting Single FSRRM24 mounts in plastic track (included) or up to two FSRRM24s in an FSRRM-S1 111" track ordered separately. FSRRM24s should be installed in an MFC-A enclosure. Operating Environment Temperature: 32 - 120° F (0- 49° C); Humidity: 93% RH, non-condensing Dimensions 2-3/4" W x 3-3/8 H x 1-1/2" D (65.9 mm W 85.7 mm H x 38.1 mm D) F-Series Remote Annunciators FSRAIO FSRA10C Common Controls No I Yes Compatibility 10-Zone Panels Only. Dimensions 5-5/8' x 81/2" x 11/2" in (14.3 cm 21.4 cm x 3.8 cm) Mounting North American 4-inch square electrical box Power Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) Data Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) twisted pair (6 twists per foot minimum) Operating voltage 18.8 to 27.3 Vdc Supply must be UL/ULC listed for fire protective signaling systems. Do not use FACP accessory power outputs that are interrupted when the panel is reset. Standby current 17 mA Alarm current 98 mA Operating environment Temperature: 32 to 120°F (0 to 49°C); Humidity: 0 to 93% RH, noncondensing at 90 °F (32 °C) FSUIM Universal Input Module Mounting MFC-A enclosure - Wire size 12 to 18 AWG (0.75 to 2.5 sq mm) Operating voltage 21.2 to 27.3 Vdc Circuit capacitance 0.03 pF, max. Circuit resistance 13 ohms, max. Switch inputs Quantity: 5 End-of-line resistor: 4.7 k ohms ½ W Relay outputs Quantity: 9 Type: Common Style: Form C Contact rating 30 Vdc at 1 A (resistive load) Standby Current 53 mA Alarm Current 114 mA Operatingenvironment Temperature: 0 to 49 °C (32 to 120 °F); Humidity: 0 to 93% RH, noncondensing at 32 °C (90 °F) Page 5018 51FTK85OO5O126 , - - '.. ' c- -. Issue 2.2 o. 0 01 Surface mounting holes - 0 E U) E U) 'Cl, 0 0 0 Dl D4 Control Panel Specifications Control Panels FX-1OR(D) FX-5R(D) Initiating Device Circuits - IDCs (Available combinations shown at right) Class B 10 8 6 4 2 0 5 3 1 1 Class A 0 1 2 3 4 5 0 1 2 Notification Appliance Circuits - NACs (Available combinations shown at right) Class B 4 2 2 0 2 0 Class A 0 1 1 2 0 1 Power Supply 7.5 amps total 4.25 amps total NAC Voltage Rating 24 Vfwr Maximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each 3.5 amps total AC Input 120 Vac 60 Hz... 230 Vac 50/601-lz... 2.2 amps 1.1 amps 1.25 amps 0.6 amps Base Panel Current Draw Standby... Alarm... 128 mA 242 mA (104 mA) (224 mA Pand Battery Charge Capacity (sealed lead acid onM Up to two 24 Ah batteries, 18 Ah in cabinet Up to 24 Ah, 10 Ah max in cabinet * Auxiliary Current 0.5 amps max. May be programmed as resettable. Auxiliary Output 24 Vdc regulated lDC Alarm Current 3.0 mA (Consult detector compatibility list p/n 3101019-EN for maximum detectors per circuit) IDC Circuit Maximum loop resistance: 26 Ohms; Maximum loop capacitance: 0.03 pF lDC Operating Voltage 16.9 to 29 Vdc UL Detector lD 103 Alarm Contact (normally open Form C) 30 Vdc @ 1 A (-esistive load) Trouble Contact (Form C) 30 Vdc © 1 A (-esistive load) .UIVIUFy L01111 k1l1.urI1dIIy Op(I rurtil 20 VOC l9 I Iresistive ioaai Operating Environment Temperature: 32 - 120° F (0 - 49° C); Himidity: 5 - 93% RH, non-condensing Terminals (wire gauge) 18 - 12 AWG (0.7E mm2 -2.5 mm2) Asynchronous Serial Communications Maximum resistance: 13 Ohms; Maximum capacitance: 0.03 pF UL564 (S3000), ULG-S527, CSFM, If larger batteries are required, use an external battery DACT - F-DACT (mounts _in_panel) Receivers Supports two receivers with two phone numbers each Communications Protocol Contact ID (SlA DC-05), 4/2 iSIA DC-02 P3) Programming Front panel controls or PC with appropriate software Telephone line connection Two RJ31X (plug-to-plug) cords supplied with DACT Telephone lines Twc or one loop start lines on the public switched telephone network. Pulse or DTMF. Telephone wall connector RJ31X/CA31X equiv. or RJ38X/CA38X equiv. Communications Compliance Industry Canada CS-03; FCC/CFR 47 Parts 15 & 68; NFPA 72; UL 864; ULC S527 Operating Environment Temperature: 32-120° F (0-49° C); Humidity: 93% RH, non-condensing Current requirements Standby: 65 mA; Alarm: 107 mA Agency Listings UL864 (S3000), CSFM, FDNY -- Dimensions S Model DI* D2 D3 D4 D5* Five- 19.5 in 3.75 in 9.13 in 10.5 in 14.23 in zone (49.5 cm) (9.5 cm) (23.2 cm) (26.67 cm) (36.14 cm) Ten- 30 in 3.75 in 7.75 in 21.27 in 15.0 in zone (76.2 cm) (9.5 cm) (19.7 cm) (54.0 cm) :38.1 cm) *Add 11/2 inches (3.81 cm) to D1 and D5 dimensions for trim kit S Page 6of8 DATA SHFET K850050126 Nit to b u.cd fr nstuUatlol ... Issue 2.2 Ordering Information Part Ship Wt. lb. Description (kg.) Number Control Panels FX-10R Conventional Fire Alarm Control Panel, Red -10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of lDCs and NACs convertible to single Class A circuits), 120VAC power source, 24VDC output Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of FX-10RD lDCs and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 30.5 (13.8) 24VDC output FX-1ORF Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of lDCs and NACs convertible to single Class A circuits), 120VAC power source, 24VDC output, French Canada Fx-5R Conventional Fire Alarm Control Panel, Red - 5 Class B lDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of lDCs and NACs convertible to single Class A circuits), 120VAC power source, 24VDC output Conventional Fire Alarm Control Panel, Red - 5 Class B lDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of lDCs - 1EE and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 24VDC 24.4 (11.1) output FX-5RF Conventional Fire Alarm Control Panel, Red, 5 Class B lDCs and 2 Class B NACs, 3.5A NAC Power, 120V, 24Vdc Output, French Canada F-TR1M35R Semi-flush trim ring for FX-5R(D) 1.7 (0.8) F-TRIM1 OR Semi-flush trim ring for FX-10R(D) 2.2(l.0) Related Items F-XTR120 Expander Transformer, 120 Vac - For FX-10 only 4.0 (1.8) EOL3 6-1 1 Required UL listed End of Line Resistors - One 3.6K Ohm and one 1.1K Ohm. 0.1 (0.5) One required for each IDC configured as combination watertlow and supervisory. EOL-P1 Required ULC listed End of Line Resistor Plate - includes one 1.1K, 3.6K and 4.71K Ohm resistor 1.0 (0.5) Off Premises Communications F-DACT Upload/dowload digital Communicator/modem/LCD module (Mounts in control panel) 1.0 (0.5) F-DACT1 Digital Communicator/Modem/LCD module (Compatible with new v4.0 control panels) F-DACT1 F Digital Communicator/Modem/LCD module (Compatible with new v4.0 control panels), French CTM City Tie Module (Requires 4" square or 2-gang North American electrical box) 1.0 (0.5) RPM Reverse Polarity Module (Requires MFC-A or other listed fire alarm enclosure) 3.0 (1.4) Remote Annunciation Remote System Indicator - Includes LEDs for display of Power, Alarm, Supervisory, Trouble and Ground Fault, FSRSI trouble sounder and silence/lamp test switch. Single gang trim plate included, multi-gang plates ordered 0.3 (0.1) separately. Mounts in a single or multi-gang North American electrical box. FSRZIA Remote Zone Indicator - Includes red LEDs for five lDCs. Single gang trim plate included, multi-gang plates 0.3(0.1) ordered separately. Mounts in single or multi-gang North American electrical box. Remote Zone Indicator - Includes LEDs for five lDCs. Single gang trim plate included, multi-gang plates ordered FSRZI-SA separately. Mounts in single or multi-gang North American electrical box. Jumper selected Alarm (red) or 0.3 (0.1) Supervisory (amber) indications. FSAT1 Annunciator Trim Plate, 1 gang 0.1 (0.05) FSAT2 Annunciator Trim Plate, 2 gang 0.1 (0.05) FSAT3 Annunciator Trim Plate, 3 gang 0.1 (0.05) FSAT4 Annunciator Trim Plate, 4 gang 0.1 (0.05) K-FSRA10 Single Unit 10 zone remote annunciator for FX-10 K-FSRA1 OF Single Unit 10 zone remote annunciator for FX-10, French K-FSRA10C Single Unit 10 zone remote annunciator for FX-10 (with common controls) K-FSRA10CF Single Unit 10 zone remote annunciator for FX-10 (with common controls), French FSUIM Common Function Graphic Driver/Interface - 9 relays and 5 switch inputs for common system indicators & controls Remote Relay Module FSRRM24 Remote Relay Module - Five Form C relays. Configurable for lDCs 1-5, or 6-10, or common system indications or 0.4(0.2) matrix mode. Requires MFC-A or other listed fire alarm enclosure. FSRRM-S1 1 11" Mounting track. Holds up to two FSRRM24s. 0.4 (0.2) - Accessories MFC-A Multi-function Cabinet (fire alarm accessory enclosure) 7.0 (3.2) Programming Tools - 0 1---- FA-CU Fire alarm configuration utility. This CU is available for download only. Visit www.kiddefx.kidde.com. Page 7 of 8 fl A 1 F .,•' ' . K85005-0126 Issue 2.2 I Kidde çfllflhfTlmtrl.r; Technology that saves lives Contact us... Email: kidde.flre@fs.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. Al rights reserved. Page 8o18 DATA S 4FET K85005-0126 Not 10 used or ir tUion Issue 2.2 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0102' Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models FireShield series FS302x, FS502x, FS1004x, *Models FireShield Plus FSP302x, FSP502x, FSP1004x, *Models FireworX series FX-3xJ1FX-5 FX-10x and *Models FSC- series E-FSC302x, E-FSC502x, E-FSCI004x fire alarm control units. The suffix 'x' may include any of the following alpha and/or numbers: G, R, G-2, GF, GD,RD GC or *F Models FSDACT and *F..DACT digital alarm communicator transmitter. Local, auxiliary, central station, remote station, automatic, manual, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal'), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-1591:102, 7165-1501:129 7-29-10 ma s This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires (June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division We vant you to be completely satiated 'MId every battery uu purchase from Interstate Ballsrfen,cem. If yco are not completely satisfied 'sith an item that you parcnased, you may return moo items Mlhin 45 days o: delivery for a fall refund of tie purchase price, minus the shipping thurges. For exceptions, please refer to Warranty Exclusions and Return Exclusions. 0 cnismieenomacr 86€-842-5368 Sign In I Sign Up I My Account I Track My Order About tin I Recridint I Help HOME HOMES WORKS UGHTINGS HEALThS BATTERIES VEHICLE ACCESSORIES ELECTRONICS GARAGE OFFICE SECURITY MEDICAL BY TYPE BATTERIES Cart: (0 Items) $' Need inienrtalioff& t*1 Shrppng' 1 6 0 linepurchases only Juno 27-July I. I 15% OFF* COUPON CODE: POWER Eichairmns apply. ET#JLSffERE. Home -1 Sealed Lead Add / SLAv> 12V 8.OAH SLA .250 FASTON The Power Patrol SLA1 079 battery is sized, tested and rated On meet enact manufacturer, OEM and safely standards. Every Power Patrol S1A1079 is constructed with the best materials available including Ile latest Absorbed Glass Mat (ACM) technology giving you increased durability, superior performance, longer ran times between charges and longer overall battery life. See the Also Fits tab for a list of applications. Live Chat Enter Email Address Your Price: $34.99 ListPrice: $4,8B - IN STOCK Order by 1pm CST— ships earn. drnr Specifications Reviews Also Fits ['stuses11arranty [ Features/Benefits 1. Product ID: SLA1079 Milliamp Hours: 0 Voltage: 12 Termination: .250" FASTON SPADES Chemistry: SEALED LEAD ACID Weight (Ibs): 5.15 Width (in): 2.5600 Length (in): 5.95 Height (in): 3.70 V Email Customer ServIce. Call Toll Free: 866-842-5368 Need a custom battery?a HELP ABOUT BATTERIES CORPORATE OUR BUSINESS Customer Service . Safety Data Sheets(SDS) About Us Location Finder Site Map FAQ Career Center All Battery Centars Privacy Policy BaeeryTerrns News &Press Distributorships International Shipping Recycling Racing PewerCenter Shipping Policy Warranty Team Member PuwerCare Conditions of Use Class Action Settlement Affiliates All Battery Franchising - View products by: Title, Category, Pose, SKU Vow toysette rs by: title, Category, Price, 5KV Popular ite en by Popularity, O Choices, All-Round Favorites, Title @2016 Interstate Batteries A A CELLULAR ALARM o TG=7FS C 0 M M U N I C A T 0 R FOR 3G/4G NETWORKS TE LG UAR D COMMERCIAL FIRE 11 PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self-tests. ii Falls back to 2G (GSM) if a 3G/4G network isn't available. n The Tolguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems, The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landlinc replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can he installed as the sole path for commercial fire installations. For existing installations, all landlinos can be swapped for a single TG-7FS because of the new five minute supervision mode, The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. lelguard Online Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. Telguard Cellular Service Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and TIguard product questions. . Advanced Reliability Features SMS backup to reduce false alarms, providing self-tests using SMS if GPRS fails. Automatic self-tests with central station notification ensure the cellular system is operating Available relay output for tripping the alarm control panel when a trouble condition occurs. UL Listings Commercial Fire 864 Conti ci wets F accessores iot I re cli oh ss,or'is Commercial Burglary 365 Poke SLst on connectea bvc'g!i corn" units nd systems 1610 ' Cenirci station sjrgiar F-'.' unit '. L nc sc'cul .ty seivcic.s Residential 985 Household he v.5: nini systems C' i(' :00 ,r'v'rS p'oduc' rrrt thcrv. iL - rr .- ' .', .', ,', 1r'lg ,j' -j roru D LISTED f'J INVERNATIONAL NFPA 1) I CELLULAR ALARM TG=7FS COMMUNICATOED FOR 3G/4G NETWORKS TE LG UAR D Power I • Transmit power: 1.OW-2.0W I (maximum allowable). Power Consumption; I 60mA (Standby) 25OmA (Transmission). Transformer: 12VAC, 800mA UL listed plug-in. Radio Transceiver 3G cellular radio. GSM 850MHz: Class 4 (2 watts), GSM 1900MHz: Class 1(1 watt). UMTS WCDMA FDD 850/1900MHz. Antenna: 9" dipole with 2dBi gain, 12 ft of cable and universal mounting bracket. FCC part 15, 22, 24 arid 68 compliant. Physical Details TG-7FS: 7.5" H x 11.5" W x 3.5" D. Shipping Weight: 81bs. Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). Standard Features Full data reporting. Automatic self-test (5 mm. & daily). Power supply with battery harness. Locking, red metal enclosure. Two programmable supervisory trip outputs. Alarm format support ,for S1A2, Contact ID, pulse (3x1, 4x2),T modem lie, & lllabMP.. Telephone line monkor built-in, with Standard Line Security. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superi or inbuild ng penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100- 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. klqun'd. a Div:sion of leiuini Corporation 2727 Paces 0ovy Rood SE Suite 1•800 Ati,:'t,: GA 30339 USA 800-229-2326. Omen ww:v.leiguaid,cor r..Copyright 2012 Tei'jlai Corpootio All R:ynts Reserved CERTIFICATE OF COMPLIANCE Certificate Number 20120308 — S50526A Report Reference S5052 - 2007 April 26 Issue Date 2010 March 08 Issued to: TELULAR CORP 311 SWACKERDR SUITE 4300 CHICAGO, IL 60606 USA This is to certify that Control Unit Accessories, System, Control Units and Accessories, Household representative samples of System Type, Central Station Alarm Units, Police-station-connected Alarm Units & Household Burglar Alarm System Units Fire Alarm and Security Equipment: Models, TG7G0004, TG7GA004 and TG7GFS04. All these models are suitable for Standard Line Security. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 864, "Control Units and Accessories for Fire Alarm Systems," ANSI/UL 985, "Household Fire-Warning System Units," ANSI/UL 1610, "Central-Station Burglar-Alarm Units," ANSI/UL 1635, "Digital Alarm Communicator System Units," ANSI/UL 365, "Police Station Connected Burglar Alarm Units and Systems," ANSI/UL 464, "Audible Signal Appliances" and ANSI/UL 1023, "Household Burglar-Alarm System Units." Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: (!) with the word "LISTED"; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. S Wililom R. Camay, Director, North M,sflcan Certification Programs UL LLC Any Information and documentation Involving UL Mark services are provided on behalf of IL LLC (iii.) or any authorized license, of UL For qu.stlons, please contact, local UL Customer Service Representative at wyrw.uI.com!cotaclus Page 1 of 1 C 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 9402:071q9 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7LA00I *TG7LA01 TG7LA002, *TG7LAF0I TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF0I TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Q Date Issued: July 01, 2018 Listing Expires Gune 300 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 'Edwards Signaling Two-Wire Conventional Smoke Detector 511C rjIr atJjt> Conventional Initiating Overview The Edwards 5110 is an economical, conventional photoelectric, direct-wire smoke detector with drift compensation. The 5110 continually monitors its own sensitivity and operational status, and provides a visual indication if it drifts out of the sensitiv- ity range or fails internal diagnostics. Additional diagnostic informa- tion is activated by applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. The magnet test causes the LED to blink. The number of blink counts corresponds to a smoke detector sensitivity range. This meets NFPA 72 field sensitiv- ity test requirements without the need for external meters. The chance that a 5110 will need maintenance is significantly decreased because of the built-in drift compensation. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing the life of the detector. And, if the 5110 ever needs cleaning, it's literally a snap with FireworX's patented field replace- able optical chamber. The 5110 also features an alarm verification feature to further reduce the chance of a nuisance alarm. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level will initiate an alarm. See installation instructions for information about correct installa- tion and maintenance. Standard Features Self-diagnostics continually monitors detector's operation and meets NFPA 72 sensitivity test requirements Built-in drift compensation reduces nuisance alarms Field-replaceable optical chamber makes servicing a snap Small, low-profile design blends in with any environment Large SEMs type terminals speeds wiring connections while ensuring a secure connection Cost effective for the largest installations Page 1 of 2 DATA SHEET S85001-0595 Not to be Jsed for installation purpo~e5 Issue 2 Smoke Detector Techno ogy Most homes have battery operated ionization smoke detectors. T:iese detectors react quickly to flaming fires but usually take longer to detect smoldering fires - the most com- mon type of fire that occurs in homes. Edwards 511 C smoke detectors utilize photoelec- tric smoke detection technology. Photoelectric smoke detectors continually analyze the air for smoke particles and are more sensitive to smolderir.g fires than ionization detectors. Installing both ionization and photoelectric smoke detectors in your home provides the best possible protection for you and your family. Specifications Electrical Ioltá (12/24 VD (8,5-33 VDC) polanty sensitive) Maximum standby current 70pA Maximum alarm current 60mA Minimum reset time 1 sec Environmental 0 4 = viol 0 H.If.d T-h..I.M.. M q Contact us... Phone: 1-800-336-4206 Web: www.edwardssignaiing.com Edwards Signaling is an EDWARDS brand. 3 Farm Glen Boulevard Farmington, CT 06032 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: wiw.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Physical Color White Detector dimensions 5" x 2" (12 x 5cm) Base dimensions 4.75" x 3" (12.5 x 0.8cm) Drift compensation adjustment 1%/ft max IField wiring size') (18-12AWG) Regulations Usting UL 268, CSFM UL compatibility identifier Si OA Ordering Information Model Description Listing (5110: Photoelectric Smoke Detector, 2-wire, 12/24VDC, whi:e) (UL268j Accessories SM200- Smoke! in a Can® aerosol spray for func:ional testing 12PKG SM-EXT 1 Smokel in a Can® extension tube connects directly to can 211-i OPKG Replacement optical chamiers (package of 10) 500PLT-5PKG Mounting plate, adap:s 51- C to 400 Series mounting 'ootprint, 6" diameter Page 2of2 DATA SHEET S85001 -0595 Nut to ba used for installation purposes. Issue 2 C] CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM • LISTING SERVICE LISTING No. 7272-1657:0277 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models 521B,( 511C*, 5IIAFT*, 521BXT, 521CRXT (2-wire) and 541C, 54ICXT, 54IAXT (4-wire) photoelectric type smoke detectors. Model 52IBXT, 52ICRXT, 54ICXT, 5IIAFT*, and 54IAXT smoke detectors employ a supplemental heat sensor to assist the smoke detector in fire situation. This heat sensor is not a heat detector and is not intended for use in lieu of the required heat detectors. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 6.5 - 33 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with separately listed electrically compatible fire alarm control units. NOTE: Formerly: 7300-0447:140 7-29-10 ma This listing is based upon technical data submitted by the applicant, CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftV" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division