HomeMy WebLinkAbout5803 ARMADA DR; ; FPC2018-0213; PermitPERMIT REPORT C(City of Carlsbad Print Date: 05/10/2022 Permit No: FPC2018-0213 Job Address: 5803 ARMADA DR, CARLSBAD, CA 92008-4609 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track #: Applied: 07/13/2018 Valuation: $0.00 Lot #: Issued: 07/31/2018 Occupancy Group: Project #: Finaled Close Out: 11/22/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Maldonado, Adalmira Salcedo, Felix Project Title: Description: GRAND PACIFIC PALISADES RESORT - REVISED PLANS FOR UNDERGROUND HOTEL EXPANSION / EXTEND REROUTE EXISTING F SERVICE TO NEW POC AT HOTEL EXPANSION FPContractor: TRINITY GRADING INC P0 BOX 175 TEMECULA, CA 92593 (951) 587-6000 FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $136.00 FIRE Underground Piping with up to 4 Hyds/Risers $733.00 Total Fees: $869.00 Total Payments To Date: - $869.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR UNDERGROUND PIPIN G . Procedure Upon completion of work, inspection and tests shall be made by contractor's representative and witnessed by an owner's representative. All de e shalt be corrected and system left in service before contractor's personnel finally leave job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for a p p r o v i n g a u t h o r i t i e s , o w n e r s a n d c o n t r a c t o r . understood the owner's representative's signature in no way prejudices any claim agains t c o n t r a c t o r f o r f a u l t y m a t e r i a l , p o o r w o r k m a n s h i p , o r f i i l to comply with approving authority's requirements or local ordinances. DATE1112112019 PROPERTY NAME Grand Pacific Palisades Resorts Hotel Expansion PROPERTY ADDREsS5803 Armada Dr Carlsbad, CA ACCEPTED BY APPROVING AUTHORITY('S) NAMES City of Carlsbad Fire Dept ADDRESS 1635 .Faraday Ave., Carlsbad, CA I PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS . YES 0 NO EQUIPMENT USED IS APPROVED YES 0 NO IF NO, STATE DEVIATIONS: HAS THE PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCAT I O N YES 0 NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT . IF NO EXPLAIN INSTRUCTIONS ' HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHA R T S YES 0 NO BEEN LEFT ON THE PREMISES. IF NO EXPLAIN SUPPLIES BLDGS. 5803 Armada Dr., Carlsbad CA LOCATION PIPE TYPES AND CLASS PVC, DR1 4 TYPE JOINT Gasket - PIPE CONFORMS TO NFPA 24 STANDARD YES 0 NO UNDERGROUND FITTINGS CONFORM TO NFPA 24 STANDARD YES 0 NO PIPES IF NO, EXPLAIN AND JOINTS NEEDING ANCHORAGE CLAMPED, STRAPPED, OR BLOCKED IN :YES 0 NO JOINTS ACCORDANCE WITH NFPA 24 STANDARD IF NO EXPLAIN - FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreig n m a t e r i a l i n b u r l a p b a g s a t J ü t I e l such as hydrants and blow-offs. Flush at flows not less than 400 gpm (1514 I/mm) for 4-inch p i p e , 6 0 0 g p m ( 2 2 7 1 1 / m m ) f o r inch pipe, 900 gpm (2839 1/mm) for 6-inch pipe, 1600 gpm (3785 1/mm) for 8-Inch pipe, 2 4 4 0 g p m ( 5 6 7 8 1 / m m ) f o r 1 0 - i n c h p i p and 3520 gpm (7570 1/mm) for 12-inch pipe. When supply cannot produce stipulated flow rate s , o b t a i n m a x i m u m a v a i l a b e . TEST HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.8 bars) fo r t w o h o u r s o r 5 0 p s i ( 3 . 4 b a r s ) a b o v e DESCRIPTION static pressure in excess of 150 psi (10.3 bars) for two hours. 1 LEAKAGE: New pipe laid with rubber gasketed joints shall, if the workmanship is satisfa c t o r y , h a v e l i t t l e o r n o l e a k a g e a t h e joints. The amount of leakage at the joints shall not exceed 2 qts per hr (1.89 I/h) per 100 join t s , i r r e s p e c t i v e o f p i p e d i a m t e r . The leakage shall be distributed over all joints. If such leakage occurs at a few joints the i n s t a l l a t i o n s h a l l b e c o n s i d e r e d unsatisfactory and necessary repairs made. The amount of allowable leakage specifie d a b o v e m a y b e i n c r e a s e d b y I f l P in. valve diameter per hour (30 mL/25 mm/h) for each metal seated valve isolating the test sec t i o n . I f d r y b a r r e l h y d r a n t $ a r e tested with the main valve open, so the hydrants are under pressure, an additional 5 oz/min lea k a g e i s p e r m i t t e d f o r e a c h hydrant. — NEW UNDERGROUND PIPING FLUSHED ACCORDING TO NFPA 24 STANDARD YES 0 NO BY: (COMPANY) PRIORITY FIRE PROTECTION, INC. IF NO EXPLAIN HOW FLUSHING FLOW WAS OBTAINED -. THROUGH WHAT TYPE OPENING FLUSHING I1 PUBLIC MAIN 0 TANK OR RESERVOIR 0 FIRE PUMP 0 HYDRANT BUTT N OPN P TESTS LEAD-INS FLUSHED ACCORDING TO NFFA24 ' , STANDARD ' YES 0 N BY: (COMPANY) PRIORITY FIRE PROTECTION. INC. ....,,................ ... - IF NO EXPLAIN HOW FLUSHING FLOW WAS OBTAINED THROUGH WHAT TYPE OPENING Il PUBLIC MAIN 0 TANK OR RESERVOIR 0 FIRE PUMP 0 Y CONN TO FLANGE & SPIGOT 9 OF EN P cts ire IPE PE HYDROSTATIC TESTS - ALL NEW UNDERGROUND PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS - LEAKAGE TOTAL AMOUNT OF LEAKAGE MEASURED 0 GALS. OVER 2 HOURS TEST ALLOWABLE LEAKAGE GALS. OVER HOURS HYDRANTS NUMBER.INSTALLED 0 I TYPE AND MAKE ALL OPERATE SATISFACTOIL MIA. YES 0 NO I CONTROL VALVES WATER CONTROL VALVES LEFT WIDE OPEN 0 YES 0 NO IF NO STATE REASON - - HOSE THREADS OF FIRE DEPARTMENT CONNECTIONS AND HYDRANTS INTERC H A N G E A B L E WITH THOSE OF FIRE DEPARTMENT ANSWERING ALARM DYES 0 NO REMARKS DATE LEFT IN SERVICE 11/21/2019 SIGNATURES NAME OF INSTALLING CONTRACTOR Trinity Grading I nc PRIORITY FIRE PROTECTION, INC. TESTSWITNYSS.ED BY - FOR F011 I 0 DATE r I ee !, ~s(Wtl_& ~-= AQ TITLE Project Manager DATE 5/14/2020 - ADDITIONAL EXPLANATIONS AND NOTES Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the Contractor's representative and witnessed by a n o w n e r s r e p r e s e n t a t i v e . A l l e f e c shall be corrected and system left in service before contractors personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities , o w n e r s , a n d c o n t r a c t o r . I t i s understood the owner's representative's signature in no way prejudices any claim against contractor for faulty mat e r i a l , p o o r w o r k m a n s h i p , o r f a i l qre to comply with approving authority's requirements or local ordinances. PROPERTY ADDRESS 5803 ARMADA DR. CARLSBAD, CA 92008 PLANS ACCEPTED BY APPROVING AUTHORITIES (NAMES) CARLSBAD FIRE DEPT ADDRESS 1635 FARADY AVE, CARLSBAD CA 92008 INSTALLATION CONFORMS TO ACCEPTED PLANS 0 YES O NO EQUIPMENT USED IS APPROVED DYES 0 NO IF NO, EXPLAIN DEVIATIONS INSTRUCTIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION YES 0 NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THEIS NEW EQUIPMENT? IF NO, EXPLAIN HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES YES 0 NO 1. SYSTEM COMPONENTS INSTRUCTIONS YES 0 NO CARE AND MAINTENANCE INSTRUCTIONS YES 0 NO NFPA25 YES 0 NO LOCATION SUPPLIES BUILDINGS SPRINKLERS MAKE MODEL YEAR OF MANUFACTURE ORIFICE SIZE QUANTITY TEMPERATURE RATIN - GLOBE GL5601 2019 112 3 200 1 GLOBE GL4431 2019 1/2 3 155 GLOBE GL5610 2019 1/2 3 155 GLOBE GL5615 1 2019 1 1/2 3 200 PIPE AND FITTINGS TYPE OF PIPE CPVC, SCHEDULE 10, & SCHEDULE 40 STEEL PIPE TYPE OF FITTINGS CPVC & DUCTILE IRON ALARM VALVE ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTIdN OR TYPE MAKE MODEL MIN SEC FLOW FLOW SWITCH POTTER V .2% INDICATOR N/A N/A N/A N/A N/A DRY VALVE Q.O.D. MODEL SERIAL NO. MAKE MODEL SERIAL N-. MAKE .DRY PIPE OPERATING TEST N/A N/A N/A N/A N/A N/A /A TIME TO TRIP THROUGH TEST CONNECTION WATER PRESSURE AIR PRESSURE TRIP POINT AIR PRESSURE TIME WATER REACHED TEST OUTLET ALARM OPERATD PROPER MIN SEC PSI PSI PSI MIN I SEC YES NO WITH Q.O.D. N/A N/A N/A N/A N/A N/A N/A N/A N/A W/O Q.O.D. N/A N/A N/A N/A N/A N/A N/A N/A IF NO, EXPLAIN N/A OPERATION El PNEUMATIC El ELECTRIC El HYDRAULIC I DELUGE & PREACTION VALVES PIPING SUPERVISED El YES El NO DETECTING MEDIA SUPERVISED fl YES D NO I DOES THE VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS 0 YES EJ NO IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT IF NO, EXPLAIN NIA - FOR TESTING? El YES 0 NO MAKE MODE d DOES EACH CIRCUIT OPERATE SUPERVISION LOSS ALARM DOES EACH CIRCUIT OPERATE YALVE RELEASE MAXIMUM TIME T OPERATE RELEA E N/A N/A YES NO YES NO MIN SEC NIA I N/A N/A NIA N/A I N/A PRESSURE REDUCING LOCATION MAKE & SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE &FLOOR MODEL (FLOWING) VALVE TEST INLET ( PSI) OUTLET (PSI) INLET (PSI) OUTLET (PSI) FLOW (M) N/A N/A N/A N/A N/A HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above TEST pressure in excess of 150 psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to pr( i itafic vent DESCRIPTION damage. All aboveground piping leakage shall be stopped. PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop, which shall not exceed 11/2 psi (0.1 bars) in 24 Pours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 11/2 osi in 24 hogs. ALL PIPING HYDROSTATICALLY TESTED AT 205 rs1 FOR2 HOURS IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED 0 YES 0 NO EQUIPMENT OPERATES PROPERLY YES 11 NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? R YES 0 NO I DRAIN READING OF GAGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VALVE IN TEST TESTS TEST SUPPLY TEST CONNECTION 90 PSI CONNECTION OPEN WIDE 86 PSI UNDERGROUND MAINS AND LEAD-IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING. VERIFIED BY COPY OF THE U FORM NO. 858 0 YES 0 NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDERGROUND SPRINKER PIPING M YES ONO IF POWDER DRIVEN FASTENERS ARE USED IN CONCRETE IF NO, EXPLAIN HAS REPRESENTATIVE SAMPLE TESTING BEEN COMPLETED? 0 YES 0 NO - BLANK TEST NUMBER USED LOCATIONS NUMBER REMOVED GASKETS NONE WELDED PIPING M YES 0 NO - IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9. LEVEL AR 3? 0 YES 0 NO DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WELDING WITH THE REQUIREMENTS OF AT LEAST AWS D10.9. LEVEL AR 3? 0 YES 0 NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? R YES FT NO CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) (DISCS) ARE RETRIEVED? YES 0 NO HYDRAULIC NAMEPLATE PROVIDED IF NO, EXPLAIN DATA DYES ONO NAMEPLATE DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN. REMARKS 5-5-20 NAME OF SPRINKER CONTRACTOR- Western Fire Protection—J=. Tg&T§ WITNESSED BY SIGNATURES FOR PR Q (SIGNED) DATE TITL, , DATE ADDITIONAL EXPLANATIONS AND SIEMENS NFPA 72 REPORT SYSTEM RECORD OF COMPLETION Date of Acceptance:_ Supplemental Pages Attached: Yes Contract Number:440P-249521 PROPERTY INFORMATION Name of property:Grand Pacific Palisades Hotel Address: 5803 Armada Drive Description of property: Hotel Expansion Name of property representative:Grand Pacific Palisades Hotel LP (30554260), Address:5900 Pasteur Ct., Carlsbad, CA 92008 Phone:_ Fax:_ E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor:Siemens Address: 10100 Willow Creek Road, San Diego, CA, 92131 Phone: (858)693-8711 Fax:_ E-mail: Service organization:Siemens Address:10100 Willow Creek Road, San Diego, CA, 92131 Phone: (858)693-8711 Fax:_ E-mail: Testing organization:SIEMENS Address:_1 Phone:_ Fax:_ E-mail: Effective date for test and inspection contract: Monitoring organization: Address: Phone:_ Fax:_ E-mail: Account number:_ Phone line 1:_ Phone line 2: Means of transmission: Entity to which alarms are retransmitted: Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a:_ Permit number:FPC2OI9-0036 NFPA 72 edition: 2019 4.1 Control Unit Manufacturer: Siemens Model number: XLS PANEL LOCATION:GRAND PACIFIC PALISADES 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: j . Alarm verification set for NA seconds © Siemens Industry, Inc., Smart Infrastructure Division, 2009-2020. All rights reserved. This report was created by TechAdvance+TM, a service of Siemens Industry, Inc. Page 1 of 3 SIEMENS NFPA72REPORT I&tr(4Jy160p(4fr 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 12OVAC_ Control panel amps:20amps Overcurrent protection: Type:_ Amps: Branch circuit disconnecting means location:Fire Panel Room Number: 5.1.2 Secondary Power . Type of secondary power: Storage Battery Location, if remote from the plant:- GRAND PACIFIC PALISADES Calculated capacity of secondary power to drive the system: 61 .84Ah In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit Power extender panels are listed on the supplementary form Notification Appliance Power Panel Supplementary Record Of Completion. Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line No B Device Power No B Initiating Device No B Notification Appliance No B REMOTE ANNUNCIATORS Address Type Location 01:009 Remote Annunciator LOBBY ANNUNCIATOR 01:253 Annunciator(MKB/PMI) MAIN CPU INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Heat Detector 4 Addressable Alarm Multi-sensor Fire Detector 1 Addressable Alarm System Smoke Detector (P) 12 Addressable Alarm System Smoke Detector (P) (Supv) 18 Addressable Supervisory NOTIFICATION APPLIANCES Type Quantity ZH-MC-CW 3 SLFSWW-F 20 AS-75-CR-WP 10 AS-75-R-WP 2 ST-75-CW-WP 9 ZR-HMC-CW 18 SYSTEM CONTROL FUNCTIONS Type Quantity FSD Relays 3 Fire Bell 1 © Siemens Industry, Inc., Smart Infrastructure Division, 2009-2020. All rights reserved. This report was created by TechAdvance+TM, a service of Siemens Industry, Inc. Page 2 of 3 SIEMENS li44Miiy -fa r(4(t. Type Quantity Elevator Controls 1 II. INTERCONNECTED SYSTEMS This system has Interconnected systems: 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This Testing Was Performed in Accordance with Applicable NFPA Standards. Signed: Date: Printed name: Jeffrey Koishor Organization:Siemens Title:Electronics Installer Phone:(858)267-7105 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Date: Printed name: Jeffrey Koishor Organization: Siemens— Title: Electronics Installer— Phone:(858)267-7105 12.3 Acceptance Test Date and time of acceptance test: 4/28/2020 Installing contractor representative: Testing contractor representative: Property representative:..... AHJ representative: NFPA 72 REPORT 5/14/2020 5/14/2020 © Siemens Industry, Inc. Smart Infrastructure Division, 2009-2020. All rights reserved. This report was created by TechAdvance+TM, a service of Siemens Industry, Inc. Page 3 of 3