HomeMy WebLinkAbout5790 ARMADA DR; ; FPC2020-0163; PermitPERMIT REPORT (dty of Carlsbad Print Date: 05/10/2022 Job Address: 5790 ARMADA DR, CARLSBAD, CA 92008-4608 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2110222000 Track #: Valuation: $302,315.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0163 Status: Closed - Finaled Applied: 09/22/2020 Issued: 10/06/2020 Finaled Close Out: 12/03/2020 Final Inspection: INSPECTOR: Salcedo, Felix Maldonado, Adalmira Project Title: Description: MUSEUM OF MAKING MUSIC -ALARM TI (30 HORNS/STROBES) FOR REMODELED DISPLAY AREA Applicant: FPContractor: NOVA SECURITY NOVA SECURITY CORY HILL 8779 COTTONWOOD AVE, # STE 103 358 RIVER TRAIL PL SANTEE, CA 92071457 SANTEE, CA 92071-6907 (619) 448-3007 (619) 448-3007 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov F(t2,~-N65 Museum of Making Music 5790Armada Drive Carlsbad, CA 92008 Fire Alarm Submittal Remodel T.I. 09-21-2020 Submitted By; N*VA SECURITY 8779 Cottonwood Ave. Suite 103 Santee, CA. .92071 619-448-3007 Cont. Lie. C-10 4 802053 Museum of Making Music Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# Fire Alarm Power Supply 5499 SILENT KNIGHT 7300-0559:0123 Strobe Ceiling Mount SCW SYSTEM SENSOR 7125-1653:186 Horn Strobe Ceiling Mount PC2W SYSTEM SENSOR 7125-1653:188 Honeywell DSILENT' KrTIGHT 5499 Distributed Power Module The 5499 is a 9 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls that have 9-32 VDC outputs, such as the Honeywell Silent Knight Model 5208 Fire Control/Communicator. The 5499 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5499 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. CONNECTION TO LOCAL FIRE CONTROL The 5499 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5499. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5499, which pro)ides supervision between the 5499 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5499 signal circuits using the 4.71<w end-of-line resistors provided. Since the 5499 draws very little power from the control, it is possible to connect one 5499 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. 5499 F -F 'U Ui[ -3I N UL Listed for 9 amps Power supply's of notification power advanced switch mode Built-in desiqn reduces - synchronization for aging dam heat and appliances from manaqes power up to - System Sensor" ensor 50% more efficiently AMSECO, Gentex', and than other systems Wheelock' DIP switches allow for easy reconfiguration Four power-limited Ground fault detector/ L_ightweight design notification outputs; 2 indicator adds to ease of Class A or 4 Class B, or , independent trouble installation and 1 Class A and 2 Class reduces shipping B . relay costs Additionil continuous auxiliary output 3 amps per out. ut circuit AC loss delay option shuts off power to non-essential high-current accessories like * Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in 2/4 VDC filtered output ,. magnetic door holders 2 inputs; 2 Class B or voltage Class A • Stand alone operation For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc This document is not intended to he used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. ALL specifications are subject to change without notice. For Technical Support, call 800-446-644:4. 5499 Technical Specifications Model 5499 Block Diagram Signal Circuit output Signal I I Signal I Input Distribute Signal 2 Signal Circuit Output Signal 2 Power Input Module 549$ Signal 3 (Optional) Signal 4 120 VAC ______ Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SUPERVISION Amps Per Output: 3.0(9.0 amps total) The 5499 supervises a variety of functions Notification circuit output: Alarm Current (for including: typical voltages) drawn from main panels Low AC power. notification appliance circuits. Low battery condition. 12 VDC: 6.5mA * Earth ground fault. 24 VDC: One input circuit - 15 mA; Both input Auxiliary output power Limit condition. circuits -30 mA EOL supervision trouble or power Limited No. of Inputs: 2 condition at an output. Input Configuration: 2 Class B or 2 Class A When a trouble condition occurs, Firepower 5499 Input Voltage Range: 9- 32VDC creates a trouble condition on the host control Battery charging Capacity: 35.0 AH signal circuits to which it is connected. Firepower 5499 still maintains the ability to be activated by INDICATOR LIGHTS the host control. In addition, the 5499 provides a AC power on: Green Form C trouble relay output as an alternative to Battery trouble: Yellow using the notification circuittrouble. ,.. ._ urounu lauti; 1L1UW PHYSICAL Aux trouble: Yellow Dimensions: 12.25"W x 16" H x 3" D 30.88 cm W x Output troubles (14): Yellow 40.64 cm H x 7.62 0 cm ORDERING INFORMATION ENVIRONMENTAL 5499: Distributed Power Module Operating Temperature: 32°F to 120°F (0°C to 49°C) ACCESSORIES Humidity: 10°/s - 93% non-condensing) SK-SCK: Seismic Compliance Kit ELECTRICAL AGENCY LISTINGS AC Input: 120ACat3.OA ULlisted Output: 24VDC at 9A CSFM 73000559:123 Current Standby: 75mA Meets NFPA 72 requirements Alarm:205mA MEA429-92EVoiXIl Auxiliary Power Circuit: 1 OSHPD (CA) OSP-0065...10 Notification Circuits: 4 Output Configuration: 2 Class A 4 Class B (1 Class A&2 Class B) For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road HOfle3llvell Northford, CT 06472 Doc 3503961 Rev HlO5/18 ?SILENT' 800-328-0103 © 2018 Honeywell International Inc.J KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRA LISTING SERVICE LISTING No. 7300-0559:0123 00 Page 1 of 1 CATEGORY: 7300 --FIRE ALARM CONTROL UNIT ACSSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com - DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Rece 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 . Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM _$. SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrA lertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. SPECTPAlert Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module The SpectrAlert SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation, SpectrAlert Advance utilizes a universal mounting plate so you can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING <S> USTED APPROVED approved 7125-1653.0166 (,ndoor strobes) 7125-16530188 (hors strobes, 04011 (chirrres, horn strobes, horns) 3223572 MEA452-05.E chime strobes) S5512 (strobes) 7135-1653.0189 (horns, chimes) SpectrAlert Advance Specifications General ( SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x AN box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 7 back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit h erminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the SyncsCircuit ° Module accesso , shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The hon shall have three audibility.optioris and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more Synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash ner second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) , 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) lnputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCR, SBBCW) Notes: 1 Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs 2. F, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSrn1O1 8-17.5 Volts DC 123 142 148 NA NA NA NA 16-33 Volts DC FWR 66 71 77 81 94 96 158 153 Candela Standard Candela Range 15 15/75 30 75 UL Current Draw Data 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15)75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 - 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, High 177 185 Candela Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214229256262 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWRDC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes AVOS1O1O1 Alert Advance Dimensions & 1— 2.5 8 a. Ceiling-mount horn strobes Ceiling back box surface mount back box SpectrAlert Advance Ordering Information Ceiling Horn Strobes PC2R 2-Wire Horn Strobe, Standard Cd, Red PC2R-P 2-Wire Horn Strobe, Standard Cd, Red, Plain (no "FIRE") marking PC2RH 2-Wire Horn Strobe, High Cd, Red PC2W 2-Wire Horn Strobe, Standard Cd, White PC2W-P 2-Wire Horn Strobe, Standard Cd, White, Plain (no "FIRE") marking PC2W-SP 2-Wire Horn Strobe, Standard Cd, White, "Fuego" marking PC2WH 2-Wire Horn Strobe, High Cd, White PC2WH-P 2-Wire Horn Strobe, High Cd, White, Plain (no "FIRE") marking PC2WH-SP 2-Wire Horn Strobe, High Cd, White, "Fuego" PC4R 4-Wire Horn Strobe, Standard Cd, Red PC4RH 4-Wire Horn Strobe, High Cd, Red PC4W 4-Wire Horn Strobe, Standard Cd, White Ceiling Strobes SCR Strobe, Standard Cd, Red SCRH Strobe, High Cd, Red SCW Strobe, Standard Cd, White SCW-P Strobe, Standard Cd, White, Plain (no "Fire") marking SCWH Strobe, High Cd, White Accessories SBBCR Surface Mount Back Box, Ceiling, Red SBBCW Surface Mount Back Box, Ceiling, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard Cd" refers to strobes that include 15, 15/75,30,75,95, 110, and 115 candela settings. "High Cd" refers to strobes that include 135, 150, 177, and 185 candela settings. S}'STElV7 3825 Ohio Avenue • St. Charles, IL 60174 02015 system sensor. Product specifications subject to change without notice. Visit syslemsenSor.csm 5EIJSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS1O1O2.03/15 on, including the latest version 51 this data sheet. for current product information, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRA \" LISTING SERVICE %3 LISTING No. 7125-1653:0186 ço)( ,, \* Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE EARINGIMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email megan.sissonhoneywell.cdm DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 85cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other. Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL u -FIRE 'ENGINEERING - BUILDING MATERIALS LISTING PROGRAffi.1 LISTING SERVICE \vs~ LISTING No. 7125-1653:0188 c Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE EARINGIMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P41RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC Ceiling) and *SA\f\/BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division