Loading...
HomeMy WebLinkAbout7190 AVENIDA ENCINAS; ; AS050250; PermitJob Address: Permit Type: Parcel No: 7190 AVENIDA ENCINAS SPRINK Lot #: 0 Reference No.: PC #: City of Carlsbad Sprinkler Permit Permit No: AS050250 Status: PENDING Applied 12/8/2005 Approved: Issued: Inspector: Project Title: NORTH ISLAND CREDIT FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: WESTERN FIRE PROTECTION 12232 THATCHER CT P0 WAY CA 858-513-4949 Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0 115 0 City of Carlsbad 07-28-2005 Fire Department Permit Permit No: FAD05023 Job Address: 7190 AVENIDA ENCINAS CBAD Permit Type: FADD Subtype: HYD Status:6"lann f7j% Parcel No: Lot #: 0 Applied: Issued:19/ WOO Fire Dept Ref#: Building Permit#: Entered By: BSM Location Project Title. POINSETTIA VILLAGE Descripp: \ HYDRANT FLOW TEST ON 8/4/05 Contrctor: ALTERNATIVE F RE Phone: 619-280-8295 3 SITY AV Fax: SAN DIEGO CA 92104 Total Fees $65.00 Total Payments To Date $0.00 Permit Fee $65.00 Additional Permit Fee $0.00 Re-Inspection Fee 0 $0.00 Other $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $65.00 404 08/12/05 0002 Oi 02 COP 6500 NOTICE: Please take NOTICE that approval of your project includes the"Imposition" of fees, dedications, reservations, or other exactions hereafter col l e c t i v e l y referred to as fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you p r o t e s t t h e m , y o u m u s t follow the pretest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manage r f o r processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. FIRE PREVENTION DIVISION 1635 FARADAY AVENUE, CARLSBAD, CA 920087314 I7fl\ fl')..Ar A.11em:ative Fire CoMPLEI YSMS * fLc;N. FABRICATION & FNTALLATR) w\' 74. 1..AKr LINCflE CA 9 23? IRON0 (909) 245./TIn ( C-(C) I FL(i)\VTE ST DATE -Jo-c FLOW TEST AT .Pocii •'UA STATICREADQ_ ...L_.......... RESIDUAL READING 0. PIT-0 READING ........--....-- WITNES s:ED By. •1 UJ. COMPANY In :( QUICK RESPONSE RECESSED HORIZONTAL SIDEWALL 4. QUICK RESPONSE A UTOMA TIC SPRINERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDE WALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible' glass ampule as the / thermosensitive element. This provides sprinkler operation approxi / ( ! mately six times faster than ordinary sprinklers. While the Quick . Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers . ..'./ the additional feature of greatly increased safety to life. Quick Response e Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly QUICK RESPONSE is a hermetically sealed frangible glass ampule that contains a precisely RECESSED PENDEN1 measured amount of fluid. When heat is absorbed, the liquid within the ,bulb- expands increasing the internal pressure.; At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge Which is distributed in an approved pattern depending upon the deflector style used. - TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-55°C). Frame - bronze - Deflector - brass Screw - brass. . Bulb seat - copper Spring - nickel alloy Seal - teflon Bulb - glass with alcohol based solution, 3mm size. Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 35 FuSS F 57 C/68 C ORANGE/RED 1007 38'C INTERMEDIATE 175'F/200'F 79'C/93'C YELLOW/GREEN 150 F 66'C HIGH 286'F 141 C BLUE 225 F 107'C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 5 1 7-846-4583 • FAX 5 17-846-923 I NOVEMBER 2000 A-7 . BULLETINGL28OI oA. QUICK RESPONSE A UTOMA TIC SPRINKLERS G T'S EkiES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES 2.8 (39 metric) 1/2' NPT 2 114' (5.7 cm) Factory Bronze 4.2 (59 metric) /2" NPT 2 /4" (5.7 cm) 'Satin Chrome Bright Chrome 5.6 (80 metric) 1/2" NPT 2 114" (5.7 cm) White Polyester* (1 II metric) '' 1/2" NPT 21/4" (5.7cm) Black PoIyster+" 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) '4°11-ead Coated NOTE: METRIC CONVERSIONS ARE APPROXIMATE. *HORIZONTAL SIDEWALL IS 2 9/16'. FINISHES AVAILABLE ON SPECIAL ORDER. +AVAILABLE AS UL LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE K FACTOR 135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C 286°F 141°C U.L.MEA U.L.CANADIAN FM L.P.C..Y.C.-D.O.B. I0I-92-E 2.8 X X X X X X X --- --- x 14.2 'X'"X X X x PENDENT 5.6 X X X X X X X X X X RECESSED t 7,8* X X X X X X X X --- X 8.1 X X X X X X X X X X 2.8 X X X X X X X --- --- X HORIZONTAL SIDEWALL 4.2 X X X X X X X --- --- x 'RECESSED § 5.6 ''x' x x x '" x x x --- -.- ",. x 8.1 X X X X X X X --- --- X § HORIZONTAL SIDEWALL U.L. AND C-U.L. LISTED FOR DEFLECTOR 4" TO IT, BELOW THE CEILING. tLISTEDD FOR ALL HAZARDS. CROSS SECTIONS * 7/32" X /2" I ORDERING INFORMATION SPECIFY Quantity Model Number Style Orifice Thread Sizes Temperature Finishes desired Quantity - Recessed Wrenches - P/N 325391 (112"); P/N 325401, Rev. F (L.a.) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any off its own manufac- tured products found to be defective in ma:eerial or workman- ship for a period of one year from date ci shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). - 2 15/16" DI*- 2" OIA. SIN, 1 29/32" 0*. X S0s,C2''N., Cu REWCER RETAINER - ( qat MIN. ki ffil SIN OO**S 1 3/9 MAX —j :--I--L PENDENT HORIZONTAL SIDEWALL LOBE® FIRE .SPRINKLER CORPORATION NOVEMBER 2000 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 517-846-4583 FAX 517-846-9231 1-800-248-0278 www.gkDbesprinkler.com PRINTED U.S.A. BULLETIN GL280