HomeMy WebLinkAbout2720 CIRCULO SANTIAGO; ; FPC2018-0018; Permit21II:11I.]l city 0.f 4f Carlsbad Print Date: 05/11/2022 Job Address: 2720 CIRCULO SANTIAGO, CARLSBAD, CA 92008-6831 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1672504400 Track #: Valuation: $280,000.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0018 Status: Closed - Finaled Applied: 01/11/2018 Issued: 01/18/2018 Finaled Close Out: 03/02/2021 Final Inspection: INSPECTOR: Wong, Cindy Project Title: Description: THE RESERVE: BLDG #4 -FIRE ALARM TI (PANEL SWAP OUT) FPContractor: ALL COUNTY FIRE PROTECTION INC 10965 SAN DIEGO MISSION RD SAN DIEGO, CA 92108-2431-SAN DIEGO (619) 284-4770 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 LI Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 J Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev@honeywell.com DESIGN: Models 2W-B,2WT-B, 4W-B and 4W1-B photoelectric type smoke detectors. Models 2W-B and 2WT-B a}e 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2W1-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 / 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires tJune 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division System Sensor /3 series smoke detectors represer significant advancement in conventional detecti The /3 family is founded on three principles.' instal. . -. Photoelectric Smoke Detectors SYSTEM $ SENSOR ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling -Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms -Simplified sensitivity measurement -Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & <~> 0 MEA MSFM LISTED APPROVED approved approved S911 3011446 7272-1653:152 295-01-E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pie-wire bases (included with heads).The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock" action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire il detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the j3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. / °s. (j) Smoke Detector S Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2\NT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions, When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings I011 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2VVT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4\A/T-B only: 41°F (5°C) Sensitivity 2.51/6/ft nominal InputTerminals 14t022 AWG Mounting II'1iTe. : 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Power-Up Sequence for LED Indication Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Thermal 2W-B No Wiring Alarm Current W 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20mA@12'/23mA@24V 4W1-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter SYSTEM 0~~ 020D9 System Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Product specifications subject to change wthout notice. \Asit systernsensoccom for Phone: 800-SENSOR2 . Fax: 630-377-6495 current product information, includ,ng the latest version of this data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I - - LISTING No. 713570569:0126 J Page 1 of I CATEGORY: 7135--AUDIBLE DEVICES LISTEE: Gentex Corporation 10985 Chicago Drive, Zeeland, MI 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestric©gentex.com DESIGN: Model GX9I !GX93 and *GTMH horn. Model GX-93 has selectable temporal 3 or continuous temporal tons*Mddel GTMH has selectable temporal 3 or continuous tones. *Model GTMH has temporal 4 tones when used with Gentex GTSM synchronization module (CSFM Listing 7300-0569:0149) or Gentex GTSM synchronization protocol in a separately listed compatible control unit. The model number may be followed by a letter indicating product color. Refer to listee's data sheet for additional product description and operational considerations. RATING: Electrical: 8-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings and UL label. APPROVAL: Listed as horns for use with separately listed compatible fire alarm control units. Suitable for wall or ceiling mount. For indoor use only. Model GX93 and GTMH can generate the distinctive three-pulse Temporal 3 Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Model GTMH can generate the distinctive four-pulse Temporal Pattern 4 for Carbon Monoxide Signal in accordance with NFPA 720 when used with Gentex GTSM synchronization module (CSFM Listing 7300-0569:0149) or Gentex GTSM synchronization protocol in a separately listed compatible control unit. *Rev. 08-31-16 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division / I 2/24VDC, Low Current GX93 Mini-Horn with Terminal Blocks Applications The GX93 Series mini-horn is a high quality remote audible signaling appliance that offers dependable remote annunciation. The GX93 is ideal for applications where a dependable audible alarm signal is required in applications such as hotels, dormitories and apartments. The GX93 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. The GX93 can be used on the same sync circuit (AVSM Series Control Module) as other Gentex signals. The GX93 Series is ANSI/UL 464 listed for use with fire protective systems and are warranted for three years from the date of purchase. Standard Features Single unit is capable of 12 or 24 Variety of mounting options for new VDC determined by the input construction and retrofit voltage applications Unit dimensions: 4.48" (11.38 cm) Synchronize using the Gentex high x 284" (7.21 cm) wide x 0.5" AVSM Series control module (see (1.27 cm) deep Technical Bulletin 015) Jumper selectable temporal 3 or ANSI/UL 464 listed for fire continuous tone protective service Horn frequency is 3100Hz Textured finish high impact plastic Terminal blocks (12 AWG to 18 faceplate, available in red or off - AWG) white Low current consumption Model Number Part Number GX93-R 904-1276-002 GX93-W 904-1277-002 GX93-PR 904-1267-002 GX93-PW 904-1268-002 NOTES: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. SERIES Product Listings SIGNALING ® LISTED ANSI/UL 464 Listed CSFM Listing 7135-0569:126 BFP (City of Chicago) MEA #285-91-E-XVI Product Compliance NFPA72 IBC/IFCI1RC Quality Management System is certified to: ISO 9001:2008 NEA. MEMBER ASSEMBLED IN THE USA Model Designations = Red faceplate = Off-White faceplate "P" = Plain Operating temperature - Indoor use only Indoor: 320 to 120°F (00 to 49°C) GX93 Current Ratings 24VDC 22mA 24VDC UL Max' 18mA 12VDCULMax1 13mA Horn Minimum SPL at 10 feet per Minimum SPL at 10 feet per Reverberant dBA In Anechoic Mode ANSI/UL 464 ANSI/UL464 at 10 feet per Room dBA at 24VDC at 12VDC ANSI/UL 464 @ lO ft. empora1 3 F 81 dBA 78 dBA 78-86 90 ontinuous 86 dBA 83 dBA 78-86 90 1 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the ANSI/UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (BVDC for 12VDC units). For audibles the max current is Usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mini-Horn Wiring Mini-Horn Mounting UL GX-93 I -93 I LISTED CONTROL [HI PANEL S LI PER S ED I __________________ END OF LINE SIGNAL RESISTOR CIRCUIT \ RED e BLACK BLACK,, BLACK1 I BLACK Wiring Diagram Use screwdriver to break jumper for L continuous tone, L DO NOT BREAK + JUMPER IF TEMPORAL 3 TONE IS NEEDED. Architect & Engineering Specifications The alarm horns shall be Gentex model GX93. The appliance shall be listed with Underwriters Laboratories (ANSI/UL) for use with fire protective signaling systems (ANSI/UL 464) and produce a peak sound output of 9OdBA or greater as measured in an anechoic chamber. The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC. The appliance shall be provided with 2 terminals, and mount to a variety of single-gang back boxes. 24 units per carton 6 pounds per carton [ lnrpertant Notice: - 03 G E I-J 1 E)(These materials have been prepared by Genteo Corporation ('Genloo) for Informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Con. ac- CORPORATION materials curate,PtO dnot :compliance with all dress all legal tirele ons vant rlocal, federal laws, regulations d In em is Inevitable uncertainty regarding ,The laws. regulations n activ • rules a h: 0tm0 l ties a, regulations and rules 10 particular tact patterns. Fire Protection Products Group • www.gentex.com Each ion of can differently affect the obligations that exist under applicable laws, regulations 0, 10985 Chicago Drive • Zeeland, Michigan 49464 only for informational purpose: and should not used as a suUstitute for seeking professional legal advice. Gent" will not be responsible for any action or failure to 616.392.7195 • 1.800.436.8391 • 616.3924219 Fax act in reliance upon the information contained In this material. Canton Corporation reserves the right to make changes to the product data sheet at their discretion. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. LJ150-1657:olllj Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models 270, 27013, 270-SPO, 270A-SPO, 270-DPO, 270A-DPO, 270-DOC, 276B, 277B, 278B, 279B, 279TC, 279P, 2791, 279L, 276A-REL, 278A-REL, 5966B, 5966BR, 596613V, 5966BRV, 629613-270, 6296B-K279, 6296B-1279, 8557-13301, 8557-13311, 8558-13301, 8558-13311 and 8558-13312 manual pull stations*. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as non-coded fire alarm pull stations for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: 1. Models provided with two-wire lead and normally closed switch contacts are not approved for fire alarm signaling use. 2. Formerly 7150-1591:111, 7150-1388:121 and 7150-0073:117 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June3O, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division UXIVE-ritionzo rntatng ,,Edwards Signaling Fire Alarm Station 270 Series i MEA Edwards 270 Series Non-Coded Fire Alarm Stations are sturdy; attractive, and designed for economical installation. -Pie station is available in the following operational and functionaJ designs: - The 210 Series provides a single action, break glass initiat- ing station. It is available with normally open (ftO), normally closed (N.C.) or combination N.O./N.C. contacts. The basic 270 Series have screw terminals for field connection. The 270A Series Manual Stations have 6 inch (150mm) wIre leads. All non-coded statins are designed for either flush or surface mounting. For flush mounting a 4 inch standard North Ameri- can square box with single gang plaster cover should be used. For surface mounting the 270 Series, use P027193 Cast Box, P039250 Steel pox. Standard Features Pull lever Simple positive operation Break glass Attractive, streamline design Less than 5 l pull force complies with ADA Solid die-cast metal construction S85001-0303 Not to 44 uu ipu. ISSU06 Mounting 1DB cTzz iXA.'O W, L tktv ITcT5w5t1AO Contact us... 't.. worowi / r Phone: 1-800-336-4206 I MY Web: www.edwardssipnalinci.com I Edwards Signaling is an EDWARDS brand. 3 Farm Glen Boulevard - Farmington, CT 06032 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com 1_L pv1A5$ROD Al Web: wwwchubbedwards.com FWSH ewUULON © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change . . without notice. Edwards is part of UTC . -.-.•1 = —I Climate, Controls & Security, a unit of .- United Technologies Corporation 1 Ordering Information All models are fire alarm red with Aluminum Strips. WARNING: These devices will . They are marked "Pull in Case of Fire' on the pull handle. operate without electrical power. Cat No Markin 1. g 1.11 Sw 11 itch Contacts Field Connections Pre As fires frequently cause paw- (top of . Signal er interruptions, we suggest you device) Si 11 ngle Doubl 11 eO 11 penScrew Wire Pre- discuss further safeguards with your Pole Pole Circuit Terminals Leads Signal local fire protection specialist 270-DPO Fire Alarm ., .................................................... 270-SPO Fire Alarm / / / 270A-DPO Fire Alarm / 270A-SPO Fire Alarm Page 2 of 2 DATA 7773, S85001-0303 NQt to he d te r.1ala1ienourposes. Issue CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. : 7165-0075:0200 j Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model MS-2 and MS-4 fire alarm control units. Model MS-2 suitable for local, central station and proprietary (protected premises). Model MS-4 suitable for non-coded; local, remote station, auxiliary, proprietary (protected premises) and central station (protected premises) when used with appropriate option modules and additional separate listed equipment; automatic, manual, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-2, -4 Control Unit 411, 411UD, 411UDAC DACT 4XTMF Transmission Module CAC-4 Converter Module RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control panel for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires 'June 30, 2018j Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division / DF-52266:62 • A2-260 MS-4(E) Fl re.uTeaAtarms Fire Alarm Control Panel by Honeywell General The Fire-Lite MS-4 and MS-4E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to con- ventional fire controls. The MS-4 is compatible with the j3TM smoke detectors from System Sensor, with drift compensation, maintenance alert, and freeze warning. Automatic synchroniza- tion of audio/visual devices with three selections for manufac- turer protocol. The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires. The MS-4 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire.Lite Device Compatibility Document for a complete list of compatible devices. Note: Unless indicated otherwise, the term "MS-4" refers to both MS-4 and MS-4E models. Features Four Style B (Class B) Initiating Device Circuits (lDCs). Two Style V (Class B) NACs. Optional module that converts all four lDCs and two NACs to Class A operation. 24VDC. j3TM Technology features: - Drift compensation automatically adjusts detector sensitiv- ity and increases resistance to false alarms caused by dust accumulation. - Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). - Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. - Wireless handheld sensitivity meter eliminates the need for voltmeters, magnets, and a physical connection to the detector. The reader displays sensitivity in terms of percent per toot obscuration and provides text status indication. - Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. - Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: - Synchronization of standard ANSI audible signals as required by NFPA 72. - Synchronization of ADA compliant strobes per NFPA 72. - Selectable for System Sensor, Wheelock, and Gentex protocols. - Selective Silence feature for manual silence of horns while strobes continue to flash on the same NAC. - Alarm verification selectable for each zone. - Disable switches provided per zone. NACs programmable for: - Silence Inhibit - Auto Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady signal - Silenceable or Nonsilenceable Silent or audible Walk Test operation mode commanded from the front keypad, with automatic return-to-normal after one hour of inactivity. Each zone may be prgrammed for supervisory or fire; each zone has separate red and yellow LEDs. Zone 4 is programmable for combination of tamper supervi- sory monitoring and waterflow alarm. Form-C Alarm, Trouble, and Supervisory relays. 3.0 A total usable current. 6.0 A total usable current available wit optional second transformer. Control buttons: - ACK (Acknowledge) - Alarm Silence - Reset —Walk Test - Zone Enable/Disable (one per zone) LED indicators: - Fire Alarm (one pe zone) - Supervisory (one per zone) - Trouble (one per zcne) - Maintenance (one per zone) - AC Power - NAC Disable - Zone Disable - NAC Fault - System Trouble - Power Trouble - Walk Test - Alarm Silence - Earth Fault (on circuit board) - Battery Fault (on circuit board) - Charger Fault (on circuit board) Piezo sounder for atarm, trouble, supervisDry and mainte- nance. Optional plug-in 4XTMF transmitter module. Optional plug-in 4XZMF zone relay module. Optional 4XLMF traismitter module for RZA-4XF remote LED annunciator. Optional dress panel. oF-52266:B2 • 12/2:1/2012 - Page 1 of 2 Operation Activation of a compatible smoke detector or any normally-open fire alarm initiating device activates audible and visual signaling devices, illuminates an indicating LED, sounds the piezo sounder at the FACP, activates the FACP alarm relay and oper- ates an optional module used to notify a remote station or initi- ate an auxiliary control function. Specifications AC POWER - T83 MS-4: 120 VAC, 50/60 Hz, 2.3 A. MS-4E: 240 VAC, 50 Hz, 1.15 A. Wire Size: Minimum 14 AWG (2.0 mm2) with 600 V insulation. BATTERY (SEALED LEAD-ACID ONLY) - J8 Maximum charging circuit: normal flat charge 27.6 VCD © 0.8 A. Maximum battery charger capacity: 18.0 AR battery (two 7.0 AH batteries can be housed in the FACP cabinet. Larger batteries require a separate battery box such as the Fire-Lite BB-17F). INITIATING DEVICE CIRCUITS - TB3 Alarm zones 1 - 4. Power-limited circuitry. Operation: all zones Style B (Class B). Normal operating voltage: nominal 20 VDC. Alarm current: 15 mA minimum. Short-circuit current: 40 mA maximum. Maximum loop resistance: 100 ohms. End-of-line resistor: 4.7K ohm, ½ watt (P/N 71252). Standby current: 4 mA. Compatible devices: refer to the Fire-Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. NOTIFICATION APPLIANCE CIRCUITS - T92 Two NAGs. Power-limited circuitry. Normal operating voltage: nominal 24 VDC. Maximum signalling current: 2.5 A total with standard trans- former 5.0 A total (2.5 A maximum per NAC) with optional transformer. End-of-line resistor: 4.71K ohm, ½ watt (P/N 71252). Compatible devices: refer to the Fire-Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. FORM-C RELAYS Trouble Relay TB5 (fail-safe). Alarm Relay TB6. Supervisory relay TB7. Relay contact ratings: 2.0 A @ 30 VDC (resistive). AUXILIARY OUTPUT: RESETTABLE POWER - T61 Operating voltage: nominal 24 VDC. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors (see notes). Power-limited circuitry. Notes: 1) Refer to the Fire'Lite Device Compatibility Document for a complete list of compatible devices. 2) Total current for nonresettable power, resettable power and two NACs must not exceed 6.0 A for the MS-4 (required optional second transformer). CABINET DIMENSIONS Door: 15.342" (38.97 cm) high x 14.667" (37.28 cm) wide x 0.375" (0.95 cm) deep. Backbox: 15.0" (38.10 cm) high x 14.5" (36.83 cm) wide x 3.0" (7.62 cm) deep. BA CKB OX MOUNTING The cabinet can be surface mounted. The door is removable during installation by opening and lifting it off the hinges. The cabinet mounts using two key slots at the top of the backbox and two additional 0.25" diameter holes at the bottom. Listings and Approvals UL Listed: S624 MEA: 297-01-E CSFM: 7165-0075:200 Ordering Information MS-4: Four-zone conventional FACP; 120 VAC, 50/60 Hz, 2.3 A. MS-4E: Same as above, but 240 VAC, 50 Hz, 1.15 A operation. CAC-4: Class A converter module. Used to convert Style B (Class B) IDC to Style D (Class A) and Style Y (Class B) NAC to Style Z (Class A). The module connects to Ji on the MS-4 cir- cuit board. 4XTMF: Transmitter module. 4XLMF: LED interface module. 4XZMF: Zone relay module, 4 form C relay. RZA:-4XF: Remote Annunciator. BB-171F: Battery box, required to house two batteries greater than 7 AH to a maximum of 18 AH. 411/411UD: Three-input (channels) model 411, and four-input model 411UD, dual-line Digital Alarm Communicator/Transmit- ters (DACTs). Can be used as slave communicators with the FACP. DP-MS2/4: Optional dress panel. MS-4RB: Replacement board. TR-1-R: Optional trim ring for semi-flush mounting. A 2-zone version of this panel is also available. See DF-52211. Fire-Lite® Alarms is registered trademark of Honeywell International Inc. 0201 1 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 110101114 A M4I1YI? All specifications are subject to change without notice. QUAtITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2- DF-52266:B2 • 12/21/2012