Loading...
HomeMy WebLinkAboutCDP 14-21; MILES PACIFIC RESIDENCES; Site PlanLEGAL DBSCRIP11ON A PORTION OF TRACT 7 OF LAGUNA MESA TRACTS, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 1719, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 21, 1921. COASTAL DEVELOPMENT PLAN FOR APN'S: 156-351-03, 07 & 08 SITE ADDRESS: 2373 & 2375 PIO PICO DRIVE, CARLSBAD, CA 92008 MILES -PACIFIC SUBDIVISION, CARLSBAD, CA SUMMARY TABLE LOT LOT SETBACKS WIDTH FRONT INT. SIDE STREET SIDE REAR 1 82 20 8.2 10 17 2 105 20 10 10 20 3 60 20 6 10 12 4 1/4 20 10 10 20 5 60 20 6 10 12 6 60 20 6 10 12 7 60 20 6 10 12 8 60 20 6 10 12 9 60 20 6 10 12 10 60 20 6 10 12 11 60 20 6 10 12 12 102 20 10 10 20 13 92 20 9.2 10 19 14 81 20 8.1 10 17 Is:,/: 81 15 8.1 10 17 16 86 20 8.6 10 17 17 73 20 7.3 /0 15 NOTES: ' MINIMUM LOT SIZE IS 7,500 S.F. , LOT WIDTH IS 60 FEET MIN. (MEASURED AT FRONT YARD SETBACK) • FRONT YARD SETBACK IS 20' ' SIDE YARD SETBACK EQUAL TO 10% OF LOT WIDTH (MIN. 5' AND NEED NOT EXCEED 10') ' STREET SIDE YARD SETBACK IS 10' 0 STREET "B" IS A DRIVE AISLE * /_OT 15 IS A KEY LOT (15' FRONT YARD SETBACK) , ALL SOUND WALLS TO BE SPLIT FACE BLOCK -TAN EASEMENT NOTE'S [I] -ABUTTER'S RIGHTS RELEASED & RELINQUISHED TO INTERSTATE 5 FREEWAY, PER DOCUMENT RECORDED: NOVEMBER 5, 1951, IN BOOK 4281, PAGE 472, DOCUMENT # 133960 OF OFFICIAL RECORDS. ll] -8.00 FOOT EASEMENT FOR PUBLIC UTILITIES, INGRESS & EGRESS TO SAN DIEGO GAS & ELECTRIC COMPANY, RECORDED: JUNE 6, 1966, AS DOCUMENT# 92989 OF OFFICIAL RECORDS. D'] -12.00 FOOT EASEMENT FOR PUBLIC UTILITIES, INGRESS & EGRESS TO SAN DIEGO GAS & ELECTRIC COMPANY, RECORDED: JULY 22, 1966, IN DOCUMENT# 119604 OF OFFICIAL RECORDS. [1J -10.00 FOOT EASEMENT FOR SEWER PURPOSES TO THE CITY OF CARLSBAD, RECORDED: JULY 28, 1967, IN DOCUMENT# 110843 OF OFFICIAL RECORDS. ~ -ABUTTER'S RIGHTS RELEASED & RELINQUISHED TO INTERSTATE 5 FREEWAY PER DOCUMENT RECORDED: JULY 15, 1969, IN DOCUMENT# 126759 OF OFFICIAL RECORDS. [§] -AGREEMENT OF RECIPROCAL SEWER EASEMENT BETWEEN MILES PACIFIC LIMITED PARTNERSHIP & FRANK/LOR/GENE SOHAEI, RECORDED: JANUARY 24, 2011, AS DOCUMENT# 2011-0042671 OF OFFICIAL RECORDS. [Z] -12.00 FOOT EASEMENT FOR PUBLIC UTILITIES, INGRESS & EGRESS TO SAN DIEGO GAS & ELECTRIC COMPANY, RECORDED: JULY, 22, 1966, IN DOCUMENT# 119603 OF OFFICIAL RECORDS. 100· 50• o· LBOBND ~ 35,5 -----"FG 1-•;·4,:-B',\' --:...c-1 -!f.,\::cJ,; ''""": - --36-- -(W)--(WJ- --cs, --CS! -- -(C)---(C)--- -(E)--(~)- (T> --(1) -- 55--- --s --s -s --o-s --w --w ---® ---® [XX] .... EXISTING ELEVATION PROPOSED ELEVA TION PROPOSED AC PVMT/BASE SLOPE DIRECTION FINISH GRADE CONTOUR PROJECT BOUNDARY RIGHT OF WAY LINE EXISTING WATER LINE EXISTING SEWER LINE EXISTING 0GAS LINE EXISTING OVERHEAD ELECTRIC LINE EXISTING OVERHEAD TELEPHONE LINE EXISTING CONTOUR MAJOR EXISTING CONTOUR MINOR PROPOSED SEWER LINE PROPOSED SEWER MANHOLE PROPOSED WATER LINE PROPOSED SEWER LATERAL PROPOSED WATER METER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED RETAINING WALL PROPOSED 6' HIGH MASONRY SOUND WALL (SLUMP STONE) PROPOSED SLOPE EMBANKMENT BUILDING SETBACK LINE COVERED VERANDA OUTLINE PROPOSED BROW DITCH K:\Land Projects 3\452-1224"G00\dwg\CDP\452-1224 CDP l.dw~, cove1; 2/5/2015 10:17:'13 AM 58' 29' ({_ 29' 0.5' 5' 5.5' 18' 18' 5.5' 5' -1---''------1---""'---'--------'"'------...+~-------""--------+---='--1-~ 5' WIDE SIDEWALK 2% 5' 2% PROPOSED 3" AC PVMT 0 VER 7. 5" AB (MINIMUM) TYPICAL SECTION STREET A (PRIVATE)-LOT20 NOT TO SCALE Tl = 4.5 34" 17' ({_ 17' 12' 12' 2% --~ ~,-•J,., 7,, 1:'i -.,L ··,-, ·-t,, ~,. ' - PROPOSED 3" AC PVMT OVER 7.5" AB (MINIMUM) TYPICAL SECIION STREET B (PRIVATE DRIVE AISLE) -LOT 20 NOT TO SCALE Tl = 4.5 2% - 5' 2% •, 4.5' WIDE SIDEWALK 100' 200· 300' "' NV APPROVED THIS IS THE APPROVED TENTATIVE ll1AP/SITE PLAN FOR PROJECT NO. CDP 14-? 1 PER CONDITION NO. _7_ &.-.;£L-1/2/f' PLAl\'NING DIVISIOK DATE _c::j;e._. ul..___:_e-..__:cli-'-"p"'-ir'-\-\-_--11/y;(i{ EKGINEERING 01v:@Bx DATE KBY MAP LBOBND (W) (S) .... [XX] o--:fj_ ~ (T) (E) SHBBTINDEX COVER SHEET SHEET REFERENCE PROJECT BOUNDARY EXISTING WATER MAIN EXISTING SEWER MAIN EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING STREET LIGHT PROPOSED STREET LIGHT EXISTING TELEPHONE EXISTING ELECTRICAL 2 PLAN \1£W (LOTS 1-4, 12-11) 3 PLAN \1EW (LOTS 5-11) 'I ~EXISTING FIRE HYDRANT SCALE: 1" = 100' 0.5' R/W R/W 40' 1D' 20' ({_ 20' PROPOSED 1 O' -s:---L STREET "A" WIDE OED/CAT/ON 10' 10'± 3'± I 8'± PROPOSED 3" AC PVMT CROWN OVER 7.5" AB (MINIMUM)~ ~ .. -- 5' WIDE SIDEWALK .--:::;,~7~'.'z:?=~~i;,:::·:::•,.==dz0 '.'24Z°L,:_z~'.'.2:~ I jT<-" 4% 2% J---~ =~ PROJECT LOCATION c:, a: ----4E~\_ -n-EXISTING GROUND PROPOSED CONCRETE CROSS GUTTER TYPICAL SECTION EXISTING AC PVMT & BASE PIO PICO DRIVE (PUBLIC) @ STREET "A" (PR/VA TE) NOT TO SCALE FLORES DRIVE REV DESCRIPTION DATE APPD VICINITY MAP N. T.S. / ,#n - VESS RONALD L. HOLLOWAY NO. 29271 97': l'JV \\. <>~ OWNE'R/DEVI3LOPBR SHEA HOMES LIMITED PARTNERSHIP 9990 MESA RIM ROAD /200 SAN DIEGO, CA 92121 PHONE: (858) 526-6554 SARAH MORRELL, AUTHORIZED AGENT ENGINEER OF WORK bliA,lnc. CDP 14~21 CT 12-01/PUD 12-08 (PREVIOUSLY CDP 12-15) land planning, cMI englneertng, surveying 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 RONALD L. HOLLOWAY RC£ 29271 PROJBCI' DATA ZONING GENERAL PLAN DES/GNAT/ON LAND USE COASTAL ZONE DRAINAGE DISTRICT.· SITE AREA DWELLING UNITS LOT SIZE: EXISTING DENS/ TY PROPOSED DENSITY GRADING QUANTITIES CUT FILL REMEDIAL AREA OF GRADING VOLUME OF GRADING PER GRADED ACRE WATER DEMAND PER 3.2.1 AND 3.2.3: FIRE PROTECTION DEMAND PER 3.2.1.C.1: A VERA GE SEWER GENERA T/ON: SETBACK DATA FRONT SIDE REAR A VBRAOB DAILY TRAFFIC EXISTING: PROPOSED: INCREASE: PUBLIC UTILITIES DATE R-1 (FAMILY RESIDENTIAL) RLM (LOW-MEDIUM DENSITY 0-4 DU/AC) RESIDENT/AL YES A (NW QUADRANT) 5.4 AC 11 D/u 7,525 SF. TO 13,626 SF. 4.00 DU/AC. 3.15 DU/AC. 9,910 CY. 9,910 CY. 69,500 CY. 6.2 ACRES (INCLUDES OFFS/TE AREA) I 598 CY. PER GRADED ACRE AVERAGE DEMAND: 2.62 GPM x 17 LOTS= 44.54 GPM PEAK DEMAND (0.48 GPM x 2.62 GPM) x 17 LOTS~ 2.14 GPM 1,500 GPM/DU X 17 DU'S= 25,500 GPM 250 GPO/LOT X 17 LOTS= 4,250 GPO OR 0.00425 MGD 20' 10% OF LOT WIDTH (2 X SIDE SETBACK) 10 ADT PER UNIT X 1 = 10 ADT 10 ADT PER NURSERY X 1 = 10 ADT 10 ADT PER UNIT X 17 = 170 ADT 150 AOT WATER SUPPLY SEWER CARLSBAD MUNICIPAL WATER DISTRICT Cl TY OF CARLSBAD GAS & ELECTRIC TELEPHONE FIRE POLICE SCHOOLS CABLE S.D.G.&£. AT&T CITY OF CARLSBAD CITY OF CARLSBAD CARLSBAD UNIFIED SCHOOL DISTRICT TIME WARNER CABLE CONSTRAINTS INFORMATION NO CONSTRAINTS EXIST. SITE HAS BEEN 100 PERCENT DISTURBED. ABBREVIATIONS AC ASPHALT CONCRETE BC BEGIN CURVE ave BEGIN VERTICAL CURVE BW BOTTOM OF WALL C&G CURB AND GUTTER CL CENTERLINE co CLEANOUT DC DEPRESSED CURB EC END CURVE EP EDGE OF PAVEMENT EVC END VERTICAL CURVE FFC FRONT FACE OF CURB FL FLOWI./NE FG FINISHED GRADE GB GRADE BREAK HP HIGH POINT hliA,lnc. land planning, cMI anglneertng, suiva~ng 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 IE INVERT ELEVATION LT LEFT MH MANHOLE NTS NOT TO SCALE PCC POINT OF COMPOUND CURVE PRC POINT OF REVERSE CURVE RCP REINFORCED CONCRETE PIPE RT RIGHT RW RIGHT-OF-WAY ss SANITARY SEWER SD STORM DRAIN SDRSD SAN DIEGO AREA REGIONAL STANDARD DRAWING SW SIDEWALK TC TOP OF CURB TW TOP OF WALL COASTAL DEVELOPNJENT PERNIJT MILES PACIFIC RESIDENCES COVER SHEET C'ARLSBAD, CA WO. 452-1224-600 SHEET __1__ OF __1_ s 2 G) 2 C s: co m :0 CJ :0 ~ 2 G) 2 C s: co m :0 CJ :0 i -2 G) 2 C s: co m :0 I ' \I .I PARCEL 3 MS 1h02 )02.40 TC \00 -. ~ ---~--" PROP!)SED PCC --~ ljRO W DITCH, TYPE -/"A" PER 0-75 Pfl;RCEL 2 //MS 11-02 PROPOSED PR/ VA TE DRAINAGE EASEMENT & COVENANT OF EASE}.IENT FOR DRAINAGE PURPOSES --==:::_++l-¼HI 0() PROPOSED PR/VA TE DRAINAGE.-'"""-+11--lnlt-HI EASEMENT TO HOA.JSLOPE,_ BROW DITCH, AND SOUND WALL TO BE HOA MAINTAINED.) PARCEL 1 MS 11-02 95.89 TC 95.0 I FL ~ TOE Q£., -8/JJPE I ,,., . '--. __ __.,...,--,, __ -~----- 12' 96.8 HP 1% MIN. "' ~ 00 -t- ~ 4' MAX RETAINING WALL 99.20 --roc <Jr Ft--- \g5_3SLOl2£.... 13 MIN. . HP ,,• ~-I COVERED PATIO 2.5' MA 0 RETA/NIN -WALL I Ll. <J) .,: .24' PROfOSEp 6' HIGH MASIJNR1 SOUND WALL (SPL/T F,f,CE BLOCK-TAN) _ _ SEE JLANIZ~CAPE PLAN _j APN 156-351-18 APN 156-351-19 PROPOSED PCC BROW DITCH, TYPE "A" PER Q~75 20' CDP 14-21 If. 5' PROPOSED 6' HIGH MASONRY SOUND WALL (SPLIT FACE BLOCK-TAN) SEE LANDSCAPE PLAN I LOT14 PE 96.0 PROPOSED PCC BROW DITCH, TYPE "A" PER 0-75 SECTIONG-G NOT TO SCALE IBFI = SEWER BACKF'LOW VAL VE 1 o' o' 20' 40' 60' bliA,lnc. land planning, cMI englneertng, su1Veylng 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 COASTAL DEVELOPMENT PERMIT MILES PACIFIC RESIDENCES CARLSBAD, CA WO. 452-1224-600 SHEET 2 OF __1_ • CJ :0 ~ 2 (j) 2 C ~ OJ m :0 CJ :ti ~ 2 G'J 2 C ~ OJ m :ti -OJ m :ti I I \ l / /\ // ' :/ ½ i"'=--++t-¥-\11---HI-I [,,,, A10P OF ~~-- / ' -;( HI'";,£/ -/ f TOE OF SLOPE LOTJ PE96.5 IBEI ! 1v,, ____ ~-------______ L 93.0 FL < ' ' J 1 I I --- . ...c:::-:_::_--=--_::__ -___ / TOP OF // SLOPE / / / / K:\Lam.1 Piojects 3\452-1224-600\dwg\CDP\452-1224 CDP 3.dwg, CDP3, 2/5/2015 10:19:15 AM I I ;..-/ j..-/ A / PROP STREET _,..-,-CIGHT-- -- LOT4 PE90.5 / TOP OF 1/ ,-,....---,,,- SLOPE // -------------t ~ ~- -\- \ LOT12 _,,.."PE94.0 IBEI \· '( -{ Ji ,,..,,..----------{_ / \_"--// \ UM/ T OF PRq?OSEO OFF-SITE GRAOING------..c 20' 10' o· CDP 14-21 CT 12-01/PUD 12-08 (PREVIOUSLY CDP 12-15) 20· 40' 60' ~ E ~--------,---s_c_A_L_E:_1'_' _=_2_0·----------1 -------- ./" / \BPI = SEWER BACKFLOW VALVE <o ~'l'-------------.W-1< RONALD L. HOLLOWAY NO. 29271 C/V\\. OF Cs\.\ ·bliA, Inc. land planning, civil englneoong, surveying 5'115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 COASTALDEVELOPMENTPERMIT MILES PACIFIC RESIDENCES CARLSBAD, CA WO. 452-1224-600 SHEET _l_ OF _l_ I \'; ~ n l~i •a O O ~~c ~Im q i~ :0 ~1 ~(I) !1 7J • ,. , ·~ " z fl z~ -1 C i! ~ ::c ~! lllQ ~ ~7] _,mm ii Ul ~ /~z z m '" ~ ... 2 GJ 2 C s: CIJ m :0 Cl :0 ~ 2 GJ 2 C ~ CIJ m :0 Cl :0 ~ 2 GJ 2 C ~ CIJ m :0 1: ! I ,, r, ! :.1 I'