HomeMy WebLinkAbout1265 CARLSBAD VILLAGE DR; 210 | 211; AS060017; Permit11/3/2020
Job Address:
AS060017 Permit Data
·city of Carlsbad
Sprinkler Permit
Permit No: AS060017
1265 CARLSBAD
VILLAGE DR
Status: ISSUED
Permit Type: SPRINK
Parcel No: 1561802100
Lot#: 0
Applied 1/27/2006
Approved: 1/27/2006
Reference No.:
PC#:
Project Title:
Applicant:
SHASTA SOUTHWEST
SUITE B
345 NO. MARKET PL
ESCONDIDO, CA
760-480-9210
Fees($)
115
Issued: 1/27/2006
Inspector:
VILLAGE OFFICE STE. #210 & 21 T.I. FIRE SPRINKLER PLAN
CHECK & INSPECTIONS
Add'I Fees ($)
0
Owner:
CARLSBAD VILLAGE DRIVE INVESTORS L L
C
C/O FRANK VIOLI
1241 CARLSBAD VILLAGE DR #100
CARLSBAD CA
-----
Total($) Balance($)
115 0
1 /1
02 .r'02/~_ 0 06 00: 55 FAX .. ~ ll!02
AS°'900l1-co)MM• '~
Contractor's Material and Test Certificate for Aboveground Piping
PROCEtJURE
Upor, m,1P416,1t, f1f .:r,c. lnlpma1 ~ ... 1h11 be made bit hi C0flhc1a(a ~ ..:I wlllaud ~ an Olffllr'• rwww....,
(hl,n,inlfta-damed•~_,..,_ Al defectl 11111111 be CXlffllded end system WI in MMCe bafcre contrKtcr'■ pnonnel ~ ..._ ,_~_
A CiiV..... •hall De filed 0UI aid aigned br bdh ~-"Cop6ea ahal bepnipnd far~ aultuiiel, a.nn. Md ca,11.-. I 11
undlnlDcd that lhe ~ «Mnllr'• aAtmmd ~a.a 1DQa1 elgnmy and July~ d 11w prq,8l1y OM11r aid fhlt br lhe
Pfq,aiyawnar'a ar~«Mnlll"• dlortz.d~•• tlgnaure, hpu,ar1yOM'81'-=capb fut ~fotlheaya8Bn•
installed ana aareee Iha it ii in .. __ wid\ lhe .. 8Ulhorlv• teQulnments and local ard.,....
Prq,ertyNane
~1 &~\/11~0~ t Datm I-Ju-6(o
Prq,ertyAddraaa l~S ~Si,60 \lti~Uf'i ui .. ~J~I
Accepcm ~~A~<N:_ane,)
{t_An1~ ~,u;i ~j,.
Addrms ,
~.octJl~' q7"09 l~S FA~'I -Pla,e l!r'v .. ll'llltalaim"t conf Offlll lo ac:cepad Plans D No
Eq~ used s appnMld IVY• □ No
lfno,~dewmm'III
Has the ~owner'~ properly (JIM1l(S aJthaiZ8d ~ been
illttucled • ID the IOCation d crnral """-#'Id ca9 -1 mantenanca" lhi9 I!( Y• ,..equc,menc? D Na
lfno,~
lnstructkln t-l.eCXC-dttl9falowilgbaMQf.-.tDlhapropsty_,..aprcperty
OMW'a IIIJthawd ~
1. Syewnea..,.--1n11rucdcn c('v. D No
2. C.. and MainllnnJD lnstrucmlt if y,. □ No
3. NFPA2S l!'v. □ No
Laaiicn SuppiesauadVlgl ~<;Nit .. Of Sy.lam
Yaw Ti
Maka Model d MMtutadure OrtfaSim Quniw RllrlD
SPf'W\kln (~ {,L~(Z_ -s-5\J -llY)5'" "It.'• ""2.~ "ZDi:l 0
(r 12 --{at--~J ~ ,A_,, ,a~ ~n a --·~ ~-~-.. ~ :l"l.-"5~~-~ ?---CD< ''" ,, ~ /5~0
P~and Typerl~ 'StMJDtl.$dw4~ F"ltiinm Tw. al Flttinm h.J~~ A C-(,
MdnLmtmelO ..... e Aam~ lfwa,gh _, cannada1
T~ ~ Medel Minutes ~
~~ ~~ \J'5g -F-_,.-~n-4.S
/Nt,~fo~ f -
DryV.,_ QO.D.
t Maka Model I Serial No. I Mike I M<del I SefWNo.
I I I I
I I I 1
Tine IO trip lf'1' Pdnt rrnew,..
thmughtes1 w .. AJr Ak Rea:hed Test Alsm()per-.d~
Ory "8 CCl\nedion. P,...ure Pmuure Pressura OlJtl8l•
0 Min/Sec l
psi psi psi Mln&ic Y• No
w/oQ.O.D.
with Q.0.D.
If No, e;,&an
•measured from tine ins,:,eaors test~ (NFPA 13 on~ raauinllS the 60-5GCCl'O limilation in specl'c sa:1icnl)
02/02/2006 00:55 FAX
Yas D No
Doe5 Nieh circuit operate
su · ioo loss 8'11nn"?
V• No
If no. e,ci,lain
Doe each circuij ooe,ate vatw
reio,asa?
Yes No
Maximum tne to Dpallte ,....
Min Ser-
I---+-------+-----+--Location Make and RflSiclUII Pressure !~"ress r--illld_F_kXJr _ __, __ M_c,de, __ --1 ____ S_Mti_·__._ ___ +-____ s_1at_~_P_,--.es,.....s_u_re ___ --+ ___ ( __ tb.Ni---r.--.a.) ___ -t-_F_law_R_at_e--a-t
I : ~:,
Tesl
Descriptiori
Tesb
Blank
Testing
Gasket&
Wetcting
Inlet
HYDROSTATIC; ¥r0&~ to=.~ shall be made al n~ le$$ lhan 200 "i (13.6 bar) for two l'lclurs or 50 pei (3.4 bat) abowttalic
pressute in acess of 150 psi (10.2 bar) (Of two hours. Differe.,tial dry-pipe~ clappers shall be left ape,, during the IMt to p,ewnl
damage. An 81:xNeground piping leakal)I shall be stopped.
PNEUMATIC: Estab'i5r. .O psi (2.7 bar) air pressure and meesura arop. which ~hall na mcceed 1 ½ f)'I (0.1 bar) in 24 haln. T•t
prassure lwtks at nonnal wateJ ~ and air pressure and measure air pre$Sure drop, wh.eh $hall nti e:w.ceed 1 ½ psi (0.1 bW) il 2,
hours.
All piping hydrostatic.ally tasted at i (_bar) ror __ hours 11 no, 1tate reu:ion
Dry ptping pneumalicall'f le5ted O Yes □ No e u· mant [ir'Ves □ No
Do )'OIi eettify as the sprinkW c:antnlcia thal additi.es and eom)GMt ehemicats. $odium silicale o, derivalNe! d sodium 5ilicala, brine,
or mta COTO&Ne chemcata _.. oaf used for tesUng system w stopping leaks? _/
~ Yes D No
Dnlin Raading_ rJ ga.,ot located ne.-.-er supply test connection Residual preuure witt'\ vet. in lest m'lnettlan ~ _.,
T•t I ~) . ( bar
U~ro-Jlld '"4\ins and~ conneda'ls to system risa,s flushed betc,e cmnection lllade \0 sprinka piping
Verified by Cf#t d the U Ferm No. 8.58 □ Y•
Flushed b-J installer d underground sprinkle( piping [SY'Yes
If po.\der-<f~ fast.-.r& ~ used 1n eoncnu, ha., D Yes
representatniie sample testing been satisfactorily
letd?
Number Used/ µ,~ Locations
0 No
D No
D No
Do )l0lJ awtify 115 the spnnlder cootrac;tor that -=ting procedures canp ly w;th the
Requirements d at least AWS 82.1?
Do )OU c;ef'trfy 11\all the wetding wa perlonned by wetderS qualified in ~plianc.e
With the ruauirer,,w\1.$ d • least AW$ B2.1?
Do you ceoify ll'\at welding WE cal'TIEld out in compliance witn a documented queUty
Control procedure to insure U,at all discs are retrifMJd, that opening$ in piping are
S,n,cnh. that 1tag and othe, ~ing ~idue are retn<Ned. and that the internal
Other
If no, sq,lain
N um bet Remow,d
~Yes
~Yes
Elq,tain
□'No
0 No
~----,:----+-,,□_iarn_at_!B d piping are n~ eene,trated?
Cutouti Do you certify lhi11 )Q.I ri~ a cOfltrof feature lo ensure that all cute)Jts (discs) are
ief' Yes No
Dist:$ Retriewd7 --.:;:;i"'~~---....--!-:------,---____________ _.=------=------
H)ldraulic Naneplste prCMded lW Yes O No If no, explain
e{ves □ No
Oata
-~~
Remal"ks Date left in seNice with all conlrol lt'aMIS open
Signatures
f; le Date
~---'-t'F"i,,,..,IL-~~----½a~-e-) ---1'?i~nature ____ 1 t>J_{_t:_d_~ ___ 1 /_i_~_{_~-~--...i
LOBE. QUICK RESPONSE
AUTOMATIC SPRINKLERS
-~-GL .. SERIES FIBE BPRINKLER COllPORADON
DESCRIPTION AND OPERATION
UPRIGHT•PENDENT
VERTICAL SIDEWALL
HORIZONTAL SIDEWALL
CONVENTIONAL (OLD STYLE)
The Globe Quick Response GL Series Sprinklers are a low
profile yet durable design which utilizes a 3mm frangible glass ampule
as the thermosensitive element. This provides sprinkler operation
approximately six times faster than ordinary sprinklers. While the
Quick Response Sprinkler provides an aesthetically pleasing appear-
ance, it can be installed wherever standard spray sprinklers are
specified when allowed by the applicable standards. It offers the
additional feature of greatly increased safety to life and is available
in various styles, orifices, temperature ratings and finishes to meet
many varying design requirements. Quick Response Sprinklers
should be used advisedly and under the direction of approving
authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuating
assembly is a hermetically sealed frangible glass ampule that contains
a precisely measured amount of fluid. When heat is absorbed, the
liquid within the bulb expands increasing the internal pressure. At
the prescribed temperature the internal pressure within the ampule
exceeds the strength of the glass causing the glass to shatter. This
results in water discharge which is distributed in an approved
pattern depending upon the deflector style used.
TECHNICAL DATA
• See reverse side for Approvals and Specifications .
• Temperature Ratings -I 35°F (57°C), I 55°F (68°C), I 75°F (79°C),
200°f (93°C}, 286°f (141 °C}.
• Water Working Pressure Rating -175 psi ( 12 Bars).
• Factory tested hydrostatically to 500 psi (34 Bars).
• Maximum low temperature glass bulb rating is -67°F (-55°C).
• Frame -bronze • Deflector -brass • Screw -brass
• Bulb seat -copper • Spring -nickel alloy • Seal -teflon
• Bulb -glass with alcohol based solution, 3mm size.
QUICK RESPONSE
UPRIGHT CONVENTIONAL
QUICK RESPONSE
PENDENT VERTICAL
SIDEWALL
QUICK RESPONSE
HORIZONTAL SIDEWALL
• SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION
ORDINARY
INTERMEDIATE
HIGH
AVAILABLE SPRINKLER
TEMPERATURES
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
JUNE 2003 A-20
BULB
COLOR
ORANGE/RED
YELLOW/GREEN
BLUE
N.F.P.A. MAXIMUM
CEILING TEMPERATURE
989-846-4583 • FAX 989-846-923 I
BULLETIN GL5615, REV. #5
,
LOBE.
FDIE SPRINKLER
CORPORA.DON
QUICK RESPONSE
AUTOMATIC SPRINKLERS
·GL9ERfES ·.
.,
UPRIGHT•PENDENT
VERTICAL SIDEWALL
HORIZONTAL SIDEWALL
DESCRIPTION AND OPERATION · CONVENTIONAL (OLD STYLE)
The Globe Quick Response GL Series Sprinklers are a low
profile yet durable design which utilizes a 3mm frangible glass ampule
as the thermosensitive element. This provides sprinkler operation
approximately six times faster than ordinary sprinklers. While the
Quick Response Sprinkler provides an aesthetically pleasing appear-
ance, it can be installed wherever standard spray sprinklers are
specified when allowed by the applicable standards. It offers the
additional feature of greatly increased safety to life and is available
in various styles, orifices, temperature ratings and finishes to meet
many varying design requirements. Quick Response Sprinklers
should be used advisedly and under the direction of approving
authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuating
assembly is a hermetically sealed frangible glass ampule that contains
a precisely measured amount of fluid. When heat is absorbed, the
liquid within the bulb expands increasing the internal pressure. At
the prescribed temperature the internal pressure within the ampule
exceeds the strength of the glass causing the glass to shatter. This
results in water discharge which is distributed in an approved
pattern depending upon the deflector style used.
TECHNICAL DATA
• See reverse side for Approvals and Specifications.
• Temperature Ratings -I 35°F (57°C), I 55°F (68°C), I 75°F (79°C),
200°F (93°C}, 286 °F ( 141 °C).
• Water Working Pressure Rating -175 psi ( 12 Bars).
• Factory tested hydrostatically to 500 psi (34 Bars).
• Maximum low temperature glass bulb rating is -67°F (-55°C).
• Frame -bronze • Deflector -brass • Screw -brass
• Bulb seat -copper • Spring -nickel alloy • Seal -teflon
• Bulb -glass with alcohol based solution, 3mm size.
QUICK RESPONSE
UPRIGHT CONVENTIONAL
QUICK RESPONSE
PENDENT VERTICAL
SIDEWALL
QUICK RESPONSE
HORIZONTAL SIDEWALL
Y • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
\ CLASSIFICATION
ORDINARY
INTERMEDIATE
HIGH
AVAILABLE SPRINKLER
TEMPERATURES
4077 AIRPARK DRIVE, STANDISH, MICHIGAN ◄8658
JUNE 2003 A-20
BULB
COLOR
ORANGE/RED
YELLOW/GREEN
BLUE
N.F.P.A. MAXIMUM
CEILING TEMPERATURE
989-8◄6-◄583 • FAX 989-846-9231
BULLETIN GL5615, REV. #5