HomeMy WebLinkAbout2722 ASCOT AVE; ; AS050030; Permit9/28/22, 10:36 AM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: Fees($) -- 220 about:blank AS050030 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050030 2722 ASCOT AV Status: ISSUED SPRINK Applied 3/11/2005 2131813000 Approved: 4/1/2005 0 Issued: 4/1/2005 Inspector: LOT 482, PA 12 FIRE SPRINKLER PLAN CHECK & INSPECTIONS Add'I Fees($) -- 0 Owner: GREYSTONE HOMES INC 1525 FARADAY AV #300 CARLSBAD CA Total($) - 220 Balance($) 0 1/1 WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #3 ASosoo?:o HYDRAULIC DESIGN INFORMATION SHEET Name -BRESSI RANCH PLANNING AREA 12 Location -CARLSBAD , CA Date -8/23/04 Building -PLAN #3 System No . - Contractor -WESTERN STATES FIRE PROT . Contract No . - Calculated By -M.G. Drawing No. - Page Date Construction: (X) Combustible ( ) Non-Combustibl e Cei ling Height VARIES OCCUPANCY -2 -STORY SINGLE FAMILY HOME s y s T E M D E s I G N Type of Calculation: ( )NFPA 13 Residenti al Number of Sprinklers Flowing : ( ) l (X) 2 ( ) Other )NFPA 13R (X)NFPA 130 ) 4 ( ) ( )Specific Ruling Made by Date Listed Flow at Start Point -18 Gpm Listed Pres . at Start Point -13 .5 Psi MAXIMUM LISTED SPACING 18 x 18 Domestic Flow Added -5 Gpm Additional Flow Added -0 Gpm Elevation at Highest Outlet -19 '-2 "Feet Note : (X) Wet ( ) Deluge Sprinkler Make RELIABLE System Type ( ) Dry ( ) PreAction or Nozzle Model Fl RES 49 Size 1/2 " K-Factor 4 .9 Temperature Rating 1 55 DEG . Calculation Summary Gpm Required C-Factor Used: Psi Required Overhead 150 At Test Underground 150 w A T E R s p p Water Flow Test : Date of Test -JULY 2004 Time of Test -N/A Static (Psi) -145 Residual (Psi) -144 Flow (Gpm) -50 Elevation -280 .0 Location : HGL 615 .0 FT . Pump Data : Rated Cap . @ Psi Elev . Other Tank or Reservoir : Cap . Elev. Well Proof Flow Gpm L Source of Information: CARLSBAD MUNICIPAL WATER DISTRICT y 1 8/23/04 vvaLt::I .:>uµµ1y 1...,u1vt:: \vJ WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #3 City Water Supgly: C1 -Static Pressure . 145 PSI C2 -Residual Pressure: 144 PSI C2 -Residual Flow 50 GPM 150 -\,, I l,;:l 140 130 p 120 R 110 (p0 h'\ E 100 .. 3 s 90 S 80 U 70 R 60 E 50 40 30 20 10 < D1 25 50 75 100 Page 2 Date 8/23/04 01 -Elevation 8.337 PSI 02 -System Flow 36.19 GPM n? -Svstem Pressure 106.566 PSI Hose J AdJ L;ny .J r,p1 ~ Hose Demand ) . 5GPM 03 -System Demand : 41 .19GPM Safety Margin 37.736 PSI 125 150 175 200 225 FLOW ( N /\ 1.85) Comouter Proorams bv Hvdratec Inc. Route 111 Windham N.H. USA 03087 fittings Summary WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #3 Fitting Legend Abbrev. Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow N PVC Standard Elbow 0 PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 8/23/04 Fittings Summary , WESTERN STATES FIRE PROT. Page 4 BRESSI RANCH PLAN #3 Date 8/23/04 Unadjusted Fittings Table 1/2 3/4 11/4 11/2 2 2 1/2 3 3 1/2 4 A 7.7 21 .5 17.0 B 7.0 10.0 12.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 9.5 17.0 28.0 E 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 G 1.0 1.0 1.0 1.0 2.0 H 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 I 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7.0 J 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16.0 K 14.0 14.0 L 1.0 1.0 2.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 N 7.0 7.0 7.0 8.0 9.0 11 .0 12.0 13.0 0 3.0 3.0 5.0 6.0 8.0 10.0 12.0 15.0 p 1.0 1.0 1.0 2.0 2.0 2.0 3.0 4.0 Q 18.0 29.0 35.0 R 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 s 4.0 5.0 5.0 7.0 9.0 11 .0 14.0 16.0 19.0 22.0 T 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 u 1.8 2.2 2.6 3.4 V 3.5 4.3 5.0 6.8 w 10.3 X 8.5 10.8 13.0 16.0 y 2.0 4.0 5.0 6.0 8.0 10.5 12.5 15.5 22.0 z 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21 .0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 47.0 E 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61 .0 F 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21 .0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11 .0 13.0 H 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 I 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 J 21 .0 25.0 33.0 41 .0 50.0 65.0 78.0 88.0 98.0 120.0 K 36.0 55.0 45.0 L 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 N 0 p Q 33.0 R s 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71.0 81 .0 91 .0 101 .0 121 .0 u 4.2 5.0 5.0 V 8.5 10.0 13.0 w 13.1 31 .8 35.8 27.4 X 21 .0 25.0 33.0 y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 fittings Summary z 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61 .0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure/ Flow Summary -STANDARD , WESTERN STATES FIRE PROT. Page 5 BRESSI RANCH PLAN #3 Date 8/23/04 Node Elevation K-Fact Pt Pn Flow Density Area Press No . Actual Actual Re . 1D 19.25 4.9 13.5 na 18.0 .05 360 13.5 2D 19.25 4.9 13.78 na 18.19 .05 360 13.5 2 20.25 13.62 na 1 20.25 13.34 na 3 20.25 14.2 na 4 20.25 21 .27 na 5 9.58 28.85 na TOR 9.58 42.83 na u 1.0 50.28 na A -3.0 58.61 na 5.0 M2 -3.0 73.78 na M1 -3.0 82.0 na SRC 0.0 106.57 na The maximum velocity is 17 and it occurs in the pipe between nodes M2 and M1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fina~ Calculations -Standard WESTERN STATES FIRE PROT. . BRESSI RANCH PLAN #3 Hyd. Ref. Point 1D to 1 2D to 2 2 to 3 1 to 3 3 to 4 4 to 5 5 to TOR TOR to u u to A A to M2 M2 to M1 M1 to SRC Qa Qt 18.00 18.0 0.0 18.00 18.19 18.19 0.0 18.19 18.19 18.19 0.0 18.19 18.00 18.0 18.19 36.19 0.0 36.19 . 0.0 36.19 0.0 36.19 0.0 36.19 5.00 41 .19 0.0 41 .19 0.0 41 .19 Dia . "C" Pf/UL 1.101 150 0.0560 1.101 150 0.0570 1.101 150 0.0570 1.101 150 0.0560 1.101 150 0.2038 1.101 150 0.2038 1.101 150 0.2038 1.049 120 0.3898 1.025 150 0.2888 1.025 150 0.3669 .995 150 0.4240 .995 150 0.4240 Fitting or Eqv. Ln. 1E 3.825 1E 3.825 1T 9.563 1E 3.825 2T 9.563 1E 3.825 3E 3.825 2T 9.563 1C 1.000 3E 2.700 18 0.0 1T 6.750 1F 1.350 2G 0.0 1T 5.841 1F 1.168 Pipe Ftng's Total 1.000 3.825 4.825 1.000 3.825 4.825 0.500 9.562 10.062 11 .500 3.825 15.325 15.580 19.125 34.705 10.670 3.825 14.495 38.000 30 .600 68 .600 8.580 1.000 9.580 8.000 14.850 22.850 40.000 1.350 41 .350 0.500 0.0 0.500 54.000 7.009 61.009 Pt Pe Pf 13.500 -0.433 0.270 13.337 13.779 -0.433 0.275 13.621 13.621 0.0 0.574 14.195 13.337 0.0 0.858 14.196 0.0 7.074 21 .270 4.621 2.954 28.846 0.0 13.982 42.830 3.716 3.734 50.281 1.732 6.598 58.612 0.0 15.170 73.784 8.000 0.212 81.996 -1 .299 25.866 Pt Pv Pn Page 6 Date 8/23/04 ******* Notes ****** K Factor= 4.90 Vel = 6.066 K Factor= 4.93 K Factor= 4.90 Vel = 6.130 K Factor= 4.93 Vel = 6.130 K Factor= 4.83 Vel = 6.066 Vel = 12.196 Vel = 12.196 Vel = 12.196 Vel = 13.435 Vel = 14 .071 Qa = 5 Vel = 16.015 Fixed loss = 8 Vel = 16.996 Vel = 16.996 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 .. F.inar Calculations -Standard WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #3 Hyd. Ref. Point Qa Qt .0 41 .19 Dia. "C" Pf/UL Fitting or Eqv. Ln. Pipe Ftng's Total Pt Pe Pf 106.563 Pt Pv Pn Page 7 Date 8/23/04 ******* Notes ****** K Factor= 3.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #4 HYDRAULIC DESIGN INFORMATION SHEET Name -BRESSI RANCH PLANNING AREA 12 Location -CARLSBAD, CA Date - Building -PLAN #4 System No . - Contractor -WESTERN STATES FIRE PROT . Contract No. - Calculated By -M.G . Drawing No. - Page Date Construction: (X) Combustible ( ) Non-Combustible Ceiling He i ght VARIES OCCUPANCY -2 -STORY SINGLE FAMILY HOME s y s T E M D E s I G N Type of Calculation : ( )NFPA 13 Residential Number of Sprinklers Flowing: ( ) 1 (X) 2 ( ) Other )NFPA 13R (X)NFPA 13D ) 4 ( ) ( ) Specific Ruling Made by Date Listed Flow at Start Point -18 Gpm Listed Pres . at Start Point -13 .5 Psi MAXIMUM LISTED SPACING 18 x 18 Domestic Flow Added -5 Gpm Additional Flow Added -0 Gpm Elevation at Highest Outlet -19 '-2"Feet Note : (X) Wet ( ) Deluge Spri nkler Make RELIABLE System Type ( ) Dry ( ) PreAction or Nozzle Model Fl RES 49 Size 1/2" K-Factor 4 .9 Temperature Rating 155 DEG. Calculation Summary Gpm Required C-Factor Used: Psi Required Overhead 150 At Test Underground 150 w A T E R s p p Water Flow Test : Date of Test -JULY 2004 Time of Test -N/A Static (Psi) -145 Residual (Psi) -144 Flow (Gpm) -50 Elevation -280 .0 Location: HGL 615 .0 FT . Pump Data : Rated Cap. @ Psi Elev . Other Tank or Reservoir: Cap . Elev. Well Proof Flow Gpm L Source of Information: CARLSBAD MUNICIPAL WATER DISTRICT y 1 8/23/04 vvatt:::1 vUIJIJIY 1...,u1vt::: lvJ WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #4 City Water SupP-ly: C1 -Static Pressure . 145 PSI C2 -Residual Pressure: 144 PSI C2 -Residual Flow 50 GPM 150 v'T C2 140 130 p 120 R 110 E 100 D2 s 90 'Pt} s 80 IJ U 70 R 60 E 50 40 30 20 10 ,b D1 • 25 50 75 100 Page 2 Date 8/23/04 D1 -Elevation 8.337 PSI D2 -System Flow 36.12 GPM n? -Svstem Pressure 88.887 PSI Hose-~ AaJ cay .J ~Pl.II Hose Demand ) : 5GPM D3 -Ststem Demand : 41.12 GPM Safety Margin 55.416 PSI 125 150 175 200 225 FLOW ( N A 1.85 ) Comouter Proorams bv Hvdratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary WESTERN ST ATES Fl RE PROT. BRESSI RANCH PLAN #4 Fitting Legend Abbrev. Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow N PVC Standard Elbow 0 PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 8/23/04 Fittings Summary WESTERN STATES FIRE PROT. Page 4 BRESSI RANCH PLAN #4 Date 8/23/04 Unadjusted Fittings Table 1/2 3/4 1 11/4 1 1/2 2 2 1/2 3 3 1/2 4 A 7.7 21 .5 17.0 B 7.0 10.0 12.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 9.5 17.0 28.0 E 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 G 1.0 1.0 1.0 1.0 2.0 H 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 I 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7.0 J 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16.0 K 14.0 14.0 L 1.0 1.0 2.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 N 7.0 7.0 7.0 8.0 9.0 11 .0 12.0 13.0 0 3.0 3.0 5.0 6.0 8.0 10.0 12.0 15.0 p 1.0 1.0 1.0 2.0 2.0 2.0 3.0 4.0 Q 18.0 29.0 35.0 R 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 s 4.0 5.0 5.0 7.0 9.0 11 .0 14.0 16.0 19.0 22.0 T 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 u 1.8 2.2 2.6 3.4 V 3.5 4.3 5.0 6.8 w 10.3 X 8.5 10.8 13.0 16.0 y 2.0 4.0 5.0 6.0 8.0 10.5 12.5 15.5 22.0 z 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21 .0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 47.0 E 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61 .0 F 5.0 "7.0 9.0 11 .0 13.0 17.0 19.0 21 .0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 H 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 I 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 J 21 .0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 K 36.0 55.0 45.0 L 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 N 0 p Q 33.0 R s 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71 .0 81 .0 91 .0 101 .0 121.0 u 4.2 5.0 5.0 V 8.5 10.0 13.0 w 13.1 31 .8 35.8 27.4 X 21 .0 25.0 33.0 y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary z 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61 .0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure/ Flow Summary-STANDARD WESTERN STATES FIRE PROT. Page 5 BRESSI RANCH PLAN #4 Date 8/23/04 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Re . 10 19.25 4.9 13.5 na 18.0 .05 360 13.5 20 19.25 4.9 13.67 na 18.11 .05 360 13.5 2 20.25 13.51 na 1 20.25 13.34 na 3 20.25 14.63 na 4 20.25 20.77 na 5 9.58 28.32 na TOR 9.58 47.01 na u 1.0 54.45 na A -3.0 62.76 na 5.0 M2 -3.0 71 .9 na M1 -3.0 80.11 na SRC 0.0 88.89 na The maximum velocity is 16.97 and it occurs in the pipe between nodes M2 and M1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 . Final Calculations -Standard WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #4 Hyd. Ref. Point 10 to 1 20 to 2 2 to 3 1 to 3 3 to 4 4 to 5 5 to TOR TOR to u u to· A A to M2 M2 to M1 M1 to SRC Qa Qt 18.00 18.0 0.0 18.00 18.11 18.11 0.0 18.11 18.11 18.11 0.0 18.11 18.00 18.0 18.12 36.12 0.0 36.12 0.0 36.12 0.0 36.12 0.0 36.12 5.00 41 .12 0.0 41 .12 0.0 41 .12 Dia . "C" Pf/UL 1.101 150 0.0560 1.101 150 0.0566 1.101 150 0.0566 1.101 150 0.0560 1.101 150 0.2031 1.101 150 0.2031 1.101 150 0.2031 1.049 120 0.3884 1.025 150 0.2877 1.025 150 0.3657 .995 150 0.4220 .995 150 0.4226 Fitting or Eqv. Ln . 1E 3.825 1E 3.825 1T 9.563 1E 3.825 2E 3.825 1T 9.563 1E 3.825 1E 3.825 4T 9.563 1C 1.000 3E 2.700 1B 0.0 1T 6.750 2G 0.0 1T 5.841 Pip.e Ftng's Total 1.000 3.825 4.825 1.000 3.825 4.825 10.330 9.562 19.892 19.330 3.825 23.155 13.000 17.212 30.212 10.580 3.825 14.405 50.000 42.074 92.074 8.580 1.000 9.580 8.000 14.850 22.850 25.000 0.0 25.000 0.500 0.0 0.500 18.000 5.841 23 ,841 Pt Pe Pf 13.500 -0.433 0.270 13.337 13.667 -0.433 0.273 13.507 13.507 0.0 1.126 14.633 13.337 0.0 1.296 14.634 0.0 6.136 20.770 4.621 2.926 28.316 0.0 18.700 47.014 3.716 3.721 54.451 1.732 6.575 62.758 0.0 9.143 71 .900 8.000 0.211 80.111 -1 .299 10.076 Pt Pv Pn Page 6 Date 8/23/04 ******* Notes ****** K Factor= 4.90 Vel = 6.066 K Factor= 4.93 K Factor= 4.90 Vel = 6.103 K Factor= 4.93 Vel = 6.103 K Factor= 4.73 Vel = 6.066 Vel = 12.172 Vel = 12.172 Vel = 12.172 Vel = 13.409 Vel = 14.044 Qa = 5 Vel = 15.988 Fixed loss = 8 Vel = 16.967 Vel = 16.967 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Standard WESTERN STATES FIRE PROT. BRESSI RANCH PLAN #4 Hyd. Ref. Point Qa Qt .0 41.12 Dia. "C" Pf/UL Fitting or Eqv. Ln. Pipe Ftng's Total Pt Pe Pf 88.888 Pt Pv Pn Page 7 Date 8/23/04 ******* Notes ****** K Factor= 4.36 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CHANGE ORDER REQUEST NUMBER fZ PRICING BREAKDOWN Material: O!Y ltem(s) Unit Subtotal $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Material Subtotal $0.00 CA State Sales Tax 7.75% @ $0.00 $0.00 Office Labor: Engineering / Design 0 Hours@ $0.00 $0.00 Purchasing / Ordering 0 Hours@ $0.00 $0.00 Misc. Expense 0 @ $0.00 $0.00 Permit/ Plan Check Fees @ $0.00 Design Subtotal $0.00 Field Labor: Fitter/ Foreman 4 Hours@ $54.58 $218.32 Supervision 0 Hours@ $0.00 $0.00 Pick-up / Delivery 0 Hours@ $0.00 $0.00 Misc. Installation Expense 0 @ $0.00 $0.00 Field Subtotal $218.32 Subcontract: Item 0 @ $0.00 $0.00 Item 0 @ $0.00 $0.00 Subcontract Subtotal $0.00 Change Order Request Subtotal $2 18.32 Markup on Subcontract 15.00% Markup on Labor 15.00% Markup on Equipment/Material 15.00% 0.00% Bond Premium 0.00% Western States Fire Protection's Total Change Order Request AmoLJnt Total $0 $0 $0 $218 $0 $218 $0 $33 $0 $0 $0 $251 (It l )__ Bulletin 135 Rev.D OJ C Reliabl~ Model F1 Residential Sprinklers Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmlft' Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F 1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res 58 Pendent 5. F1 Res 58 Pendent/F1 6. F1 Res 49 CCP Pendent 7. F1 Res 44 HSW 8. F1 Res 44 Recessed HSW/F2 9. F1 Res 58 HSW 10. F1 Res 58 HSW Recessed HSW/F2 11. F1 Res 44 SWC 12. F1 Res 40 HSW 13. F1 Res 40 Recessed HSW/F2 Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers Product Description Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The F1 Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers, with a K-Factor of 4.9, permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard *). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. F1 Res49&58 Recessed Pendent/ F1 F1 Res 49 CCP Pendent F1 Res44SWC Technical Data: F1 Res 49 Recessed Pendent/ FP F1 Res44 &58 Recessed HSW/F2 F1 Res 40 Recessed HSW/F2 • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass Casting • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½" NPT ® ½) • K-Factor: 4.9 (Actual) -F1 Res 49 Pendent Sprinkler 5.8 (Actual) -F1 Res58Pendent&HSWSprinkler 4.4 (Actual) -F1 Res 44 HSW Sprinkler 4.0 (Actual) -F1 Res 40 HSW Sprinkler • Density: Minimum 0.05 gpm/ft2 Application Model F1 Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. * Effective date 7 /12/02 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon , New York10552 ~ s· -' (.,J (J1 ::D CD ~ 0 Installation Models F1 Res sprinklers are to be installed as shown . Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP & SWC sprinklers use only the • Model F1 Res 49 & 58 Pendent r--+---~~ I I ., l:J6F002 Fig. 1 2. Model GFR1 sprinkler wrench; for installing Model F1 Res Recessed HSW sprinklers use only the Model GFR1 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 and 40 HSW with a ceiling to deflector distance of 4" -12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling . • Model F1 Res 49 & 58 Recessed Pendent/ F1 F1 escutcheon,¾" (19mm) adjustment r -+--=_,-j -, i ,Z ,ZT/,J;/" llM. -----(12.,_,] __ __,_ Fig. 2 l"ltlP"-'Gl<.alt ~~ 'll" Technical Data: F1 Res 49 Pendent and Recessed Pendent Sprinkler Max. Actual Sprinkler Thread Temp. Max. Ambient K Length Size Ratinq Pressure Temp. OF oc psi (bar) Of oc Factor Inch (mm) ½"NPT 155 68 175 (12) 100 38 (R½) 175 79 150 66 Deflector -to -ceiling Maximum 1" (25mm) to 4" (100mm) Max. Sp~inkler Flow Pressure Shac~ng gpm (Lpm) psi (bar) 12 X 12 3.6x3.6 13 49 14 X 14 4.3X4.3 16 X 16 4.9X4.9 18 X 18 5.5X5.5 20 X 20 6. 1 X6.1 4.9 2.25 (57) Sprinkler Identification Number SIN R3516 Escutcheon* F1 or F2 Data· ' ., . Adjustment "A" Face of fitting to Type lnch(mm) lnch(mm) ceiling lnch(mm) F1 ¾ (19.0) Min.=¾" (19.1 ) ¾a -'% (4.7 -24.0) Max.=1½" (38.1) F2 ½ (12.7) Min.= 11/,s" (23.8) Max.=1½" (381i ¾s -'Xs(4.7-17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler *Deflector -to -ceiling Maximum 4" (100mm) to 8" (203mm) Max. Sprinkler Spacing ft m 12 X 12 3.6X3.6 14 X 14 4.3X4.3 16 X 16 4.9X4.9 Flow Pressure gpm (Lpm) psi (bar) 18 x 18 5.5x5.5 15.0 1.0 20x20 6.1x6.1 20.2 1.4 Sprinkler Identification Number SIN R3516 * Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7" ( 178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent , Sprinkler Thread Temp. Size Rating OF oc ½"NPT 155 68 (R½) 175 79 Max. Sprinkler Spacing ft m 12 X 12 3.6X3.6 14 X 14 4.3x4.3 16 X 16 4.9X4.9 18 X 18 5.5X5.5 20 X 20 6.1 x6. 1 Max. Pressure psi (bar) 175(12) Flow gpm(Lpm) Max. Sprinkler Ambient K Terno. Factor Length lnch(mm) OF 100 150 oc 38 66 Pressure psi (bar) 5.8 2.25 (57) Ceiling-to- Deflector Inch mm 1-4 (25-100) 3. Sprinkler Identification Number SI R3513 · Model F1 Res 49 CCP Pendent 2 5/16" DIA. -------+-2 5/8" [66.7mm} DIA. HOLE IN CE/LINC [58.7mm} -+------+ CUP CUP 1"x1/2" REDUCER 1/4" 31.5mm] . FACE OF FITTING FACE OF CDLINC . , DII.IENSION "A" '-~. COVER ADJUSTMENT . HEICHT I 3 5/16" DIA. [84.1mm} F1 RES 49 CCP PEND. Fig. 3 • Model F1 Res 49 Recessed Pendent/ FP FP push-on/thread-off escutcheon 2 fJ/6" OM. {U.Tmm/ HOU I/ti CO.ING L 2 5/,&· °"'-{6&7mm} CIJP Fig. 4 J I. X 1/2" REOVCCR Technical Data: F1 Res 49 CCP and FP Sprinkler CCP Max. Thread Temp. Assembly Max. Ambient Size Rating Temp. Pressure Temp. Ratinq psi (bar) OF oc OF oc OF oc ½"NPT 155 68 135 57 175 (12) 100 38 (R½) 150 66 Max. Sprinkler Flow Pressure Spacing gpm(Lpm) psi (bar) ft m 12 X 12 3.6X3.6 7.0 0.48 14 X 14 4.3X4.3 7.0 0.48 16 X 16 4.9X4.9 8.2 0.56 18 X 18 5.5x5.5 13.5 0.93 20 X 20 6. 1 X6. 1 16.7 1.14 K Sprinkler Factor Length lnch(mm) 4.9 2.25 (57) Sprinkler Identification Number SI R3516 4. CCP O tions Data: "A" "B" FP Data "A": FP Position "A" Max. Recessed Min. Recessed Note: Sprinklers shown in Fig. 3 and Flg. 4 are not suitable for installation in ceilings which have positive pressure in the space above. · Model F1 Res 44 & 58 HSW · Model F1 Res 44 & 58 Recessed HSW/F2 F2 escutch_eon, ½" (13mm) adJustment Technical Data: F1 Res 44 HSW & HSW/F2 Escutcheon F2 Data: Sprinkler Max. Max. Sprinkler Thread Temp. Ambient K Size Ratina Pressure Temo. Factor Length OF oc psi (bar) OF oc lnch(mm) Adjustment Face of Fitting Type Inch (mm) to wall Inch mm F2 ½"NPT 155 68 175 (12) 100 38 4.4 2.45 (62) (R½) 175 79 150 66 Max. Sprinkler "A" Sprinkler Temp. Sprinkler Ceiling-to-Flow Pressure Spacing Deflector Rating gpm(Lpm) psi (bar) Identification ft(m) lnch(mm) OF(OC) Number (SIN) 12 X 12 /3.6X3.6) 155 /68) 175 /79) 12 /45.4) 7.5 (0.52) 14 X 14 /4.3X4.3) 155 (68) 175 /79) 14(530) 10.2 (0.71 ) 16 X 16 (4.9x4.9) 4-6 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 18 /4.9x5.5l (101-152) 155 /68) 175 (79) 18 (68.1) 16.8 (1 .16) 18 X 18 (5.5x5.5) 155 (68) 175 (79) 19 (72.0) 18.7 (1 .29) 16 X 20 /4.9X6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1 .89) R353 1 12x 12/3.6x36) 155 /68) 175 /79) 14 /53.0) 10.2(0.71) 14 X 14 (4.3x43) 155 (68) 175 (79) 16(606) 13.3 (0 92) 16 x 16(49x49) 6 -12 155 (68) 175 (79) 17 (64.4) 15.0 (1 .04) 16 x 18 /4.9x5.5l (152-305) 155 (68) 175 (79) 20 (75.7) 20.7 (1 .43) 16 x20 (49x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1 .89) 5. Technical Data: F1 Res 58 HSW & HSW/F2 Escutcheon F2 Data: Sprinkler Max. Max. Sprinkler Thread Temp. Ambient K Size Ratinq Pressure Temp. Factor Length Of oc psi (bar) Of oc lnch(mm) AdJ"ustment Face of Fitting Type to wall Inch (mm) Inch mm F2 ½"NPT 155 68 175 (12) 100 38 5.8 2.45 (62) (R½) 175 79 150 66 Max. Sprinkler "A" Sprinkler Temp. Sprinkler Ceiling-to-Flow Pressure Spacing Deflector Rating gpm(Lpm) psi (bar) Identification ft (m) Inch mm Of (OC) Number (SIN) 12 X 12 3.6X3.6 155 68 14 X 14 4.3X4.3 155 68 16 X 16 4.9X4.9 4-6 155 68 175 79 (101-152) 16 X 18 4.9x5.5 155 68 175 79 16 X 20 4.9X6.1 155 68 175 79 R3533 12 X 12 3.6X3.6 155 68 175 79 14 X 14 4.3X4.3 6 -12 155 68 175 79 16 X 16 4.9X4.9 (152-305) 155 68 175 79 16 X 18 4.9x5.5 155 68 175 79 6, · Model F1 Res 44 SWC /.J'JFC()7 r t I 1/4~ (.J1,7~mm] Uo~imum __ ,__ __ •· to 12· (101,6(},ttm To JfX.80mm] F oc~ Of Fitting To Woll Dimension TURN COLLAR UNnL TIGHT AGAINST SPRINKLER WlfC:NCH BOSS. J 5/16" {84.14mm] Dia. ----I 21/.J2" {42,07mm] 1/2" {12.70mm] Adji.Jstmenl F1 RES 44 SWC Fig. 5 Technical Data: F1 Res 44 SWC Sprinkler CoverTemp. Max. Sprinkler Thread Temp. Rating Max. Pressure Ambient Temp. K Length Size Ratinq psi (bar) Factor OF oc OF oc OF oc lnch(mm) ½"NPT 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) (A½) Max. Sprinkler "A" Sprinkler Spacing Ceiling-ter Flow Pressure Identification ft (m) Deflector gpm(Lpm) psi (bar) Number (SIN) Inch mm 12 X 12 3.6x3.6 13 49.2 14 X 14 4.3x4.3 14 53.0 16 X 16 4.9x4.9 4-6 17 64.3 (101-152) 16 X 18 4.9x5.5 19 71 .8 16 X 20 4.9x6.1 23 87.1 R3531 12 X 12 3.6x3.6 14 52.9 14 X 14 4.3X4.3 6 -12 15 56.7 16 X 16 4.9X4.9 (152-305) 18 68.1 16 X 18 4.9x5.5 20 75.6 7. --,--------------------_-_-_-_-_-_-_:_-_--~ -_ -_ -_ -_ -_ -_ -_ -_.-_ -_ -__ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ ---_ -_ -_ -_ -_ -_ ---_ -_ -_ -_ --- · Model F1 Res 40 HSW 135FG05 · Model F1 Res 40 Recessed HSW/F2 F2 escutch_eon, ½" ( 13mm) adJustmenl FACE OF FlrTINC TO WALL DIMENSION ---~ 1 1/4" !/IN. {.JI.Bmm} 1/B' CEIL";:;~ TO J.Zmm} DEFLECTOR D!MfNSION l1 I 2 27/32" DIA. {72.2mm} TURN COLLAR VNTIL ! TIGHT AGAINST SPRINKLER WRENCH BOSS. IJ.YG06-C L 1/2" {13mm} ADJVST!IENT F1 RES 58, 44 & 40 HSW /F2 Fig . 6 Fig . 7 Technical Data: F1 Res 40 HSW & HSW/F2 Escutcheon F2 Data: Sprinkler Max. Max. Sprinkler Thread Temp. Ambient K Size RatinQ Pressure Temo. Factor Length OF cc psi (bar) OF cc lnch(mm) Type F2 ½"NPT 155 68 175(12) 100 38 4.0 2.45 (62) (R½) 175 79 150 66 Max. Sprinkler "A" Sprinkler Temp. Sprinkler Ceiling-to-Flow Pressure Spacing Deflector Rating gpm(Lpm) psi (bar) Identification ft(m) Inch mm OF (CC) Number (SIN) 12 X 12 3.6X3.6 155 68 175 79 13 49.0 10.6 0.73 14 X 14 4.3X4.3 155 68 175 79 16 60.5 16.0 1.10 16 X 16 4.9X4.9 155 68 17 64.3 18.1 1.24 16 X 16 4.9X4.9 4-6 175 79 18 68.1 20.2 1.39 (101-152) 16 X 18 4.9X5.5 155 68 175 79 20 75.7 25.0 1.72 R3538 18 X 18 5.5x5.5 155 68 175 79 22 83.3 30.2 2.08 16 X 20 4.9X6.1 155 68 175 79 23 87.0 33.1 2.28 12 X 12 3.6X3.6 155 68 175 79 13 49.0 10.6 0.73 14 X 14 4.3X4.3 6 -12 155 68 175 79 17 64.3 18.1 1.24 (152-305) 16 X 16 4.9X4.9 155 68 175 79 20 75.7 25.0 1.72 8. Face of Fitting to wall Inch mm Finishes<11 Standard Finishes Sprinkler F1, F2, FP Escutcheons Bronze Brass Chrome Plated Bright Chrome Plated White Polvester Coated White Painted Soecial Armlication Finishes Sorin kier F1 F2 Escutcheons Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome 111 Other finishes and colors are available on special order. Consult factory for details. Maintenance Model F1 Res 49, F1 Res 58, F1 Res 44 and F1 Res 40 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model F1 RES 49 Residential Sprinkler Specifications Model F1 Res 49 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/tt2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [ 4/12) [8/12), the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)). Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49, SIN R3516 (Bulletin 135). 9. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish Model F1 Res 49 Recessed Pendent/F1, Model F1 Res 49 Recessed Pendent/F2, Model F1 Res 49 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pendent sprinklers enginewed to provide a minimum design density of 0.05 gpm/ft" over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12) [8/12), the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8'' maximum. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)) [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 3/4" adjustment (Model F1 )] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 49 Recessed Pendent/F1] [Model F1 Res 49 Recessed Pendent/F2] [Model F1 Res 49 Recessed Pendent/FP] SIN R3516 (Bulletin 135). Model F1 Res 49 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread . Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange . Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color-specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 49 CCP, SIN R3516 (Bulletin 135). Model F1 RES 40 and F1 Res 44 Horizontal Sidewall Residential Sprinkler Specifications Model F1 Res 40 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineere2 to provide a minimum design density of 0.05 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [ 4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts , and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.0 (57.1 ). Standard finish : [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 40, SIN R3538 (Bulletin 135). Model F1 Res 40 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 40 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish-specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 40/F2, SIN R3538 (Bulletin 135). Model F1 Res 44 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [ 4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread . Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish : [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 44, SIN R3531 (Bulletin 135). Model F1 Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 44 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44/F2, SIN R3531 (Bulletin 135). The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by n. 1· • bl @ The Reliable Automatic Sprinkler Co., Inc. e la I (800) 431-1588 Sales Offices · (800) 848-6051 Sales Fax . (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address JI\ Recycled ~ Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 8/04 P/N 9999970235 C c:: :c i. ..0 :'\I LLI = ~ ..0 = = ::'-I I ...D = I ~ :>.... a: CoeMJNLTY: BRESSI RANCH PA 12 PRIMROSE PmNT FINAL IW\PI: TIID ~ TEN TA lJ\/E TRACT MAP#: CT02-1-I COUNTY: S--.n Oiego SlJPERfl,(J"ENDENT: T?O ASST: TBD CONSTRUCTION PHONE•: no CONSTRUCTION FM I: TIO ADDRESS: TIil SALESOFACE S: i8D FAAI: TBO ADDRESS: TllO PHASE FM: StQU~E .Ill PUN 1 ~?" ·-·-~-~----·-·-.~-4 :::-::::-::~: ... -.. .. -:-:~ -~;:: ~ _...-1 47r" ~ 2 -'Ml!~ -JI 1 47S-4 -J>= 41r-1 t;::-;~~ J B .cu 3 i -m-4 411-..( l 48~ 3 4ao-4 47r-,>2 -4711-..(" I PUIN 1-A 3 PVIN 2 -A a 1 8 C 1 C s PLAN3-A • PUIN4-A B I B C 2 C l l lt0TAL ~ER OF HCr.lES: !;i..v.otlon 0.t..11 P!!lo l, 2,3 &:l A=Spanish B=Monlt11!7 .. RE'Jl!.IONS: 12.5.al l'l.,;-'R" COLOR ELEV. filXI& ti SCHEME ADDRESS C TRADITIOl'tAl 3 2731 Ascot Ant. A SPANISH t m7 Ai.ect A\'e. 8 MONTEREY 5 2723 Ascot A\'e. C TRADITIONAL 4 2719 Ascol Ave. a MONTEREY ti Z715 Ascol A•Je. A SPA141SH 2 2J,1 Ascot A•te. C TRADITIONAL 5 2707 Ascot Ave. C TRADITIONAL R 9 2730 AliCOI Av~. 8 MONTEREY R 7 27:26 As<CI Ave. A SPANISH R 3 Tn2..A'SCIJI. Ave. B MONTEREY R a 2718AscotAve. C TRADITIONAL R 1t 2714 Asoot A•,e. -~ SPANISH 1 2710 A:Kat Ave. B MONTEREY R ; 27C6Ascot.Ave. I 1 0 2 0 2 '2 4 1-1 DISTIUBUJION: 12.t?.Ol U~<la!M SF 211chdlfd •si-.ite• 1.25.05 t>er PCC HS 4TI rrom 3A -> 1.6. & HS 478 from 2.&.R _, 1 l!lR 4. IS.04 u~ p~.asi:t11 a i'lV'.sa<:i 'R' ~-1.25.&5 ""' P!:!C HS '4'9 from 18 _, 7.A S.21.01.-ulelr=as.P?l4 f2;i.D6C1:lo-sc.-,,.mosad!l..i fet3-.lffl 6.17.~ ~••dEno",esH/St o:~ ~~ftr;,~f.111den 1.lSAlJD,01 (:;11,.U.->~MSfU &w:11 LA->LCa.8!.aT!!oaJ'S....:-1C Prepar4d: IJIIMgfO(l R~iHd: 3.1.AI& QJ:TBO cv:teo RESIDENCE SF GARAGE SF PORCH SE 2,6C6 476 76 2,094 475 13 2,176 475 7 2,094 475 13 2,605 476 83 2,094 475 13 2,506 S60 20 2,506 56D 20 2,605 476 83 2.094 415 13 2,506 5€0 20 2.605 <175 76 2.175 475 7 2.0S4 .f75 13 .Note: ,t·· • GARAGE IS ON ft.lGKT Wttat FACING FRONT DOOR -dulota. homes nellding flro SJ)rlnllll1ts - COST CENT?R Ap~llr. JulleleHasl B!O"Altm Juu.tk'IG"' i;__,ea,. :«i11\hr.dlt•M Genual s,,~,,.. ... ,.., --y JuicaPaddat"~ su,,m..,cs.nt KN111<111:,nd .-mmr:vo.;ior I.I.~-& r~'iSa:.HS ii~~~res,,rin~~ l'".'"Ji) 3.7,05Col,r,tnn~ HS 471 tn:m:; ~ ,c_ tiS.tJ4 t.Vfft _.._, 9. ~S •11 hm ~~ 12 x-1►.ins,-sue iludolpt, ?.1S.04 C~zrgad .. l<v. Sly» ll,ls.471, 414, -4T1 \BTI Joa11-e,..,., lllru Ch•l'll«f ?Ian• ln;,nla07->~"5. Plan 324$3-> ~ Plan 22!~ irn1, Pl>:: I ~ Z!lif4 G:".SB' •1 CECKSF 0 0 68 0 53 0 6S . 85 53 0 85 0 69 a l(llitt,Rard,,alln ~ 213-16M9-00 2f 3-I 81-L'O-OO 213-181-21-00 213-181-22-<lO 21~1111-2.1-00 21~11!1-24-00 213-1111-25-00 213-181-32-00 213-1111-31-GO 213-181-JQ--(!0 213-131-29-00 21J..l8'1-23-00 213-181-27--00 2.13-181-26-00 ..... l'\J w w ....., ..... A I lJ1 ....., l'\J I A A ..... CD :£ rn ~ l"'1 ;o z ~ I> ~ l"'1 (/l "Tl ...... ;o l"'1 -0 I> G) l"'1 c.> ~