HomeMy WebLinkAboutPS 2020-0041; F45; Sign Permits/Programs (PS)Ccityof
Carlsbad
REVIEW FOR
SIGN PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760} 602-4610
www.carlsbadca.gov
D F-V 2,t:) 2--D _. t0 0 + 4-
PLANNING APPLICATION# :!:2:::9 2--o -o o ± I
REC'D BY £'ag&½ C l 111 ..:f:+:
DATE 3 / 3 I 2--0
SIGN FEE j 1,,1 -~
SIGN PROGRAM FEE ----------RECEIPT NO. __________ _
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and
sign elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
Name of Project: F45
Address of Project: ____ 7_0_3_0_A_v_e_n_id_a_E_nc_in_a_s_S_u_it_e_1_2_0 _________ _
Assessor Parcel Number: 214-430-14-00 ------------------------
Related Planning Case Number(S): ___________________ _
TYPE OF DEVELOPMENT:
(a) Residential (d) Hotel/Motel (g) Theater
(b) Commercial (e) Service Station (h) Gov't/Church/School
0) Produce Stand
(k) Nursery
(c) Office/Industrial (f) Prof. Care (i) Public Park (I) P-U/OS Zone
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes(gi NoO
Specific Plan Number (0\ V\ ~11\. V, l l ~
VILLAGE REVIEW AREA (If yes, please complete information on page ;fJ Yes a No 0
SOUTH CARLSBAD COASTAL REVIEW AREA Yes No □
SIGN ORDINANCE: Yes □ No □
COASTALZONE: Yes □ No □
P-11 Page 1 of4 Rev. 10/13
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall
Suspended/Projecting
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _
PROPOSED PERMANENT SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Pole**
Monument**
Wall 1 20.83 SF 30.00"
Suspended/Projecting 1 2.42 SF 11.80"
Directional
Canopy
Freestanding**
(Project Identity)
Digital Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-
of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be
required for such proposed signs.
P-11 Page 2 of4 Rev. 10/13
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I l I
P/L • Si&ht Distance Requirement
• I : I Show building/s . . • . I I I
: I
, ___ j Show setbacks from all curbs ---
' . • I . I ' : I : I Show all property lines I • P/L : • : I
: • I . .
curb line • . . • . I
----------~---
• •
Sight Visibility I
Street Name(s) Cil I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: ---------sq. ft.
35.00 Tot a I Building Street Frontage: ________ _ linear ft.
Total Signage Allowance: ---------sq. ft.
Existing Signage (sq. ft.): _______ _ sq. ft.
Remaining Sign Allowance at Present: ________ _ sq. ft.
23.25 Proposed Signage (sq. ft.): _______ _ sq. ft.
Remaining Sign Allowance After Proposed Sign: ________ _ sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: sq. ft. ---------
Tot a I Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of 4 Rev. 10/13
PROPERTY OWNER APPLICANT
NAME (PRINT OR TYPE) NAME (PRINT OR TYPE)
D S Properties, LP ;starf1a··•· er :.-., ... ·;., .. el< ., ,.
MAILING ADDRESS MAILING ADDRESS
100 W. High Street #58 5301 Barstow Street
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
Moorpark CA 93021 714-545-4222 San Diego CA 92117 858-735-4080
I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE
AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE
IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT
MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE.
S~Attached 02/02712020 ~-~ 02/27/2020
SIGNATURE DATE SIGNATURE DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: ❖ In right-of-way ❖ In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner: ~ ~# Date: Z>/3 /Zo
P-11 Page 4 of4 Rev. 10/13
From: Donald Pearson don@sign-ology.com @
Subject: Fwd: F45 -Poinsettia Village
Date: March 3, 2020 at 1 :48 PM
To: Stan ldeker 1 pacneon@san.rr.com, Fay Pearson fay@sign-ology.com
Don Pearson
Sign-ology, Inc.
619-623-4300
From: Don Armstrong <DArmstrong@dsrg.com>
Sent: Tuesday, March 3, 2020 1:41:33 PM
To: Donald Pearson <don@sign-ology.com>; 'F45 Training Poinsettia'
<Poinsettia@f45training.com>
Cc: Fay Pearson <fay@sign-ology.com>; Melody Alcantara <MAlcantara@dsrg.com>
Subject: RE: F45 -Poinsettia Village
Don: The proposed sign design has been approved. We will get you our formal approval letter
today.
Don Armstrong
Director -Construction
Donahue Schriber Realty Group
12925 El Camino Real, Suite J-28
San Diego, CA 92130
D:+1(858)793-5752
C:+1(714)824-0736
F: +l (714) 966-7997
darmstrong@dsrg.com
www.donahueschriber.com
From: Don Pearson <don@sign-ology.com>
Sent: Friday, February 28, 2020 12:21 PM
To: Don Armstrong <DArmstrong@dsrg.com>; 'F45 Training Poinsettia'
<Poinsettia@f45training.com>
Cc: 'Fay Pearson' <fay@sign-ology.com>
Subject: F45 -Poinsettia Village
Don, thank you for returning my call this afternoon, I look forward to working with you.
Please review the attached sign rendering and provide your teams feedback -we will adjust as
needed.
Call me if you have questions: 619-623-4300
Don Pearson
Sign-ology, Inc.
925 Hale Place, Ste. A8
Chula Vista, CA 91914
Office: 619-658-0808
Cell: 619-623-4300
Address:
' N
7030 Avenida Encinas
Suite 120
Carlsbad, CA 92011
l_
ui<n<n"inui1n
~ @ gi @ &l ~ co,-...,-...,..,_ ,-.... II)
0 -N C"'l 'Ct u, 0000 00 NNNNNN m m m m m m
'lii 'lii 't; 'lii 'lii ~ 'lii ~ 'lii 'lii 'lii C\IOOoo,-....CDOOoo ra :R :R ~ ~.: $:8~~~ .,.:~.,..:.,..:.,-·.,.:.,..:~.,..:.,--~
NM..-&nfDf'CO 0.-N 0 0 0 0 0 0 0 g ,... -_, mm mm mm mmmmm
~
~
2NDFL00R
~~~ mml ' ---I
c:m:tm
21 ,964sf PW "'~ I
~
~ v~1v,D~s
~lvc11v~s
Project Title:
F45
Scope of Work:
(1) Illuminated Wall Sign
20.83 SF
(1) Non-Illuminated Blade Sign
2.42 SF
INTERSTATE 5
~~~
R_alphs
I t ,/ 1 , , 1 .1.(..-'
55,255 sf
Assessor's Parcel #:
214-430-14-00
D ~v' '2..-02--0-C)O '-t
SIGN PERMIT NO. PS -£6 z.-o J ~bo· +• 1 I r1i
APPROVED BY DATE
PLANNING I I~ ( ,!d/f/ ' I~ . ?, . 2-o,,
I I I• ' I BUILDING I . ' . I
Legal Description :
Par 2 / Map PM15187
Owner's Information:
D S Properties 18, LP
100 W. High Street #58
Moorpark, CA 93021
714-545-4222
..
:::
0
M
Frontlit Channel Letters
2" Aluminum Return I\. ~
Aluminum Back I · ~
Acrylic Face '
Pass Through Grommet---1...J.a.~
Clinched
and Caulked Seam I~
LED Illumination I ~ !?I 51,
Drain Hole '
Sign Area: 30.00" x 100.00"
100"
20.83 SF
2" Aluminum Return
MOUNTING SCREWS
4 Nylon Anchors
with 3" X #10 SCREWS
ALUMINUM BACK
ACRYLIC FACE
2" i I / 1/2"Space
H.0 . BALLAST
L '--------" LED illumination
1"Trim Cap
0.050 ALUMINUM FRAME
• 120 VOLT SERVICE
SLEEVE TO RUN
THROUGH WALL
12/31/19 ROS
Job Location: 7030 Avenida EncinasCarlsbad, CA 92011 CLIENT APPROVAL 27
E-MAIL: ---dio.com FILE 00281
This is an original, unpublished drawing by Sign-ology It is for your personal use in conjunction with a project being planned for you by Sign-ology.
It is not to be shown to anyone outside of your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Use of this design or the
salient elements of this design in any sign done by any other company, without the express written permission of Sign-ology, is forbidden by law and
carries a civil forfeiture of up to 25% of the purchase price of the sign. Sign-ology will endeavor to closely match colors, including PMS, where specified.
We cannot guarantee exact matches due to varying compatibility of surface materials and paints used. All sizes and dimensions are illustrated for clients
conception of project and are not to be understood as being exact size or exact scale.
Non-Illuminated Blade Sign
-Sign Area : 11.80" x 29.50" = 2.42 SF
-Attached to Existing Bracket
-Aluminum Panel: Painted with Vinyl Lettering
300mm
(11 .8 ")
750mm (29 .5")
1 2/31 / 1 9 ROS
Job Location: 7030 Avenida EncinasCarlsbad, CA 9201 1 CLIENT APPROVAL 27
E-MAIL: ---dio.com FILE 00281
This is an original, unpublished drawing by Sign-ology It is for your personal use in conjunction with a project being planned for you by Sign-ology.
It is not to be shown to anyone outside of your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Use of this design or the
salient elements of this design in any sign done by any other company, without the express written permission of Sign-ology, is forbidden by law and
carries a civil forfeiture of up to 25% of the purchase price of the sign. Sign-ology will endeavor to closely match colors, including PMS, where specified.
We cannot guarantee exact matches due to varying compatibility of surface materials and paints used. All sizes and dimensions are illustrated for clients
conception of project and are not to be understood as being exact size or exact scale.