Loading...
HomeMy WebLinkAboutPS 2020-0049; MAMMA CHIA; Sign Permits/Programs (PS)( Cicyof Carlsbad MAR 21 2020 C:-iY ()F CARLSBAD PU\1\, '1 · ,i DIVISION REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov 1)£\/ 'LOZO-oci~t PLANNIN~ ~~ IcATION # PS )oa.o -o D<fl REC'D BY __ -_CcYUNX DATE 3 =I_]~ SIGN FEE ' ~ '"'00 SIGN PROGRAM FEE ________ _ RECEIPT NO. ___________ _ NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: Commerce-Cruzan Address of Project:~226 6235 5246 6~H 6 5355 6aee 5375 AvQ.Rida Encinas, Suite £ Assessor Parcel Number: -=2=-=1""'0....,-0=9=0_-4"-'1'--0=0"-------------------- Related Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) (b) Commercial (e) (c) Office/Industrial (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA 0) Produce Stand (k) Nursery (I) P-U/OS Zone Yes Iii No D Specific Plan Number PS2019-0111 VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yes D No D SOUTH CARLSBAD COASTAL REVIEW AREA Yes O No 0 SIGN ORDINANCE: Yes O No O COASTAL ZONE: Yes O No 0 P-11 Page 1 of 4 Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Walt 1 8 sf 24 Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole** Monument** "'7 -I \ .., ,, Wall 1 7,' ·--"' ,--, \I ~ V Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER-MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2of4 Rev. 02/28/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I l I PIL / Siabt ;e Requirement Shawbuildiq/1 / I I ; I ~---l Shaw setbacks &om all curti1 --- I I I I I I I Shaw all property lines I PIL I I :/ I curt, Hne i ----------~--- • • Sqht Vuilrility I Street Name(1) (i) I I Nor1h 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: ____ ..... \ -=-~-Cf-'--"(cz---=0 __ sq. ft. Total Building Street Frontage: '2...ie \., I linear ft. Total Signage Allowance: :), r sq. ft. Existing Signage (sq. ft.): C) sq. ft. Remaining Sign Allowance at Present: J. ) sq. ft. Proposed Signage (sq. ft.): "7 -l sq. ft. Remaining Sign Allowance After Proposed Sign: · 0 sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 PROPERTY OWNER APPLICANT NAME PRINT OR TYPE NAME PRINT OR TYPE CCC-Carlsbad, LLC Integrated Signs / Angela Moore MAILING ADDRESS MAILING ADDRESS 236 S. Sierra Avenue 1160 Pioneer Way, Suite M CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Solana Beach, CA 92075 619-876-6116 El Cajon CA 92020 619-733-1329 I CERTIFY THAT I AM THE LEGAL OWNER AND :r ALL THE ABOVE INFORMATION IS UE ND CORRECT TO THE BEST OF M KNO LEDGE. angela@isasign.com PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 619-579-2229 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: _____________ _ Date: _____ _ P-11 Page 4of4 Rev. 02/28/18 BILLING CONTACT CCC-CARLSBAD LLC 236 S Sierra Ave, Ste 100 Solana Beach, Ca 92075-1862 INVOICE NUMBER INVOICE DATE . 00063745 03/24/2020 REFERENCE NUMBER FEE NAME INVOICE (00063745) INVOICE DUE DATE 03/24/2020 City of Carlsbad C City of 1635 Faraday Avenue C l b d Carlsbad. CA 92008-7314 ar S a INVOICE STATUS INVOICE DESCRIPTION Due NONE TOTAL PS2020-0049 SIGN PROGRAM: SIGN PERMIT (INCL. NON-COMMERCIAL) $67.00 5205 Avenida Encinas Ste E Carlsbad, CA 92008 SUB TOTAL $67.00 TOTAL _I ______ $_&1_.o_o_ 11111111111111111 IIIII 11111 11111 111111111111111 IIIII IIIII IIII IIII March 24, 2020 3:43 pm Page 1 of 1 VICINITY MAP EB PROPERTY OWNER: Property Reserve Inc 5205 Avenida Encinas, Carlsbad, CA 92008 TENANT: Cruzan 5245 Avenida Encinas, Suite F Carlsbad, CA 92008 LEGAL DESCRIPTION: PAR 19TR 11457 LOT SIZE: 4.4 ACRES MAP# PMl 1457 ZONING: M LAND USE: LIGHT INDUSTRIAL APN: 21 0-090-41-00 ,-~, \,· lOMM[RI .,, 1:; "' 0 Cl "' ,- 5205 • 5375 AVE. ENCINAS -e,.-:;;Jl•-• ,,. ......... ~~ii .,,.,,..,,.,," ►>''"',.,,,,. _____ .,,.,,,, -tl !/fl i'/1 .,,,.,, .,-' / _,/ .,-' Dev J.-.O ~o .-~o ti,I SIGN PERMIT NO. PS 2:J.la-.0 -'664-g PLANNING BUILDING __ .3-•~?.J~-:..~------:if.,g;,:-- -------.. ,:.;.•;;.•::-t ---en,.. , .,,"'1~$. s ,/ •";.,,'!":t•·· . ~"?"' ~{:]//' .. ~0 <.Z~-~ ¼' ... '4'1 , :r-~~ ·~-§> ~.y · /<T ,~f ~ -~" "' ... :_;'1/ ~:/ ., ............ t WJ(U1 Jl i· ·m:=-5225 ; "~:"• 11251 SQ.FT. _______________________________ J.... ____ _ •'ZZ"!JtrJr•~ I aw:au flTtllln'~~ ,.,._.cl'IIIET1c _., APPROVED BY '-/. L~ ,.. ie,-,aoo· 1r_1!!--~'...1'!2.---cft.-,-:& -----~ ,........:• l·A 5375 10,638 SQ. FT.: B Jit C 11a1 . ~i . ~ ,fl! ,~11 I , ,/ I lg rf 4'----=➔~~ =~' I I -1 I I I I I I !ff ,.~ DATE 3 I ')_1-t I Jo) ,,. 1kt Vf : //" 5355 15,751 SQ. FT. I I I I I l)---3 ~ I I I I I I I I I I I I I I I I I I 1: I SITE PLAN SCALE: J"-ICXJ'-<Y' .l' ~ ,w • - ~,Ds-e Commerce cruzan Project Location: Projact No.: S1lasm1n: Dasignar: Data: Revision: 5205-5375 Avenida Encinitas Carlsbad, CA 92008 200025-01 Curt Bauer Angela M. February 21 , 2020 6 . __________ _ 6 ,__ _________ _ 6 '-------------6 ,__ _________ _ 6 '------------- 6 '-------------6 Customar Approval: Data: Landlord Approval: 0111: Printed Landlord's Name: Landlord's Phone Number: v~ ~ lnteg r!!Q~u~~~sf!~ 1160 Pioneer Way, Suite M, El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 I isasign.com I info @lsasign.com ORIGINAL CONCEPT This design Is the exclusive property of Integrated Signs and cannot be reproduced In whole or part without thelr prior written consent. Scala: As Noted Sheet No.: 1 /4 ,------~ ,------~ i•:v1ri1iTilrF '. rmir i f1·r 1·1· 1111111 , t I t BUILDING 5245 _______ , , ______ , TYPICAL ELEVATION -TENANT ID WALL SIGN LOCATION SCALE: I /32 '= 1 '-0' 19'-11 " SUITE H FRONTAGE E_Q E_Q r 19'-11 " SUITE F FRONTAGE EQ E_Q_ 16'-5" ~ 5245 ll ~: lllme :1 R'.'=1 .. YS ffl I□□□□□ r-7001~1-, □ TYPICAL ELEVATIONS SCALE: 1 /4" = 1 '-0" ~.~ ~,=ii□[DI L.....-1------- ® SEE SHEET 3 FOR SIGN SPECIFICATIONS l 16'-5" ♦ - 10·-o·:t+ - Commerce cruzan Project Location: 5205-5375 Avenida Encinitas Carlsbad, CA 92008 ProjectNo.: 200025-01 Salesman: Curt Bauer Designer. Angela M. Date: February 21, 2020 Scale: As Noted Revision: L L L L L L L L L L L L L L ~ ~ ~ Integrated SIGNS DREAM IT• BUILD IT • SIGN IT 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 lsasign.com I info@isaslgn.com ORIGINAL CONCEPT This design Is the exclusive property of Integrated Signs and cannot be reproduced In whole or part without their prior written consent. Sheet No.: 2 /4 . L/"I ¼" SUITE ID :):m~· STAND-OFFS TENANT PANEL 811 STAND-OFFS NOTE: INSTALLED ON ROCK WALL. LONGER STUDS MIGHT BE , •• , u REQUIRED 14-¼" SECTION DETAIL -ROCK SCALE: 1 1 /Z' = 1 '-0' . ' N ' 5 1/2" 42" 62" 60" · ....... t ¼" .. _:_:·.\H SUITE ID .. :·I ~½" ..... : i .. , ·.-111 TENANT PANEL ..... . . . '. · .. ·:t:tb4 STAND-OFFS ::._.-~¼" SECTION DETAIL-CONCRETE SCALE: 1 1 /Z' = 1 '-0' ~ 0 r-----------------------------, ~ 1 ~ 1 ~[1 CRUZAN I I ® QUANTITY: 49 I SIGN AREA: 7.1 SF EA .------SUITE ID PERMANENT BACKGROUND SIGN PANEL PAINTED TO MATCH MATTHEWS MP 41335SP ANODIC BLACK (SATIN FINISH). 1/8" THK. ALUMINUM PANEL SECURED 1/4" AWAY FROM WALL SURFACE WITH STAINLESS STEEL BACKPINS AND SILICONE ADHESIVE. USE 1/4" DIAM. ALUMINUM SPACERS, PAINT FINISHED TO MATCH ADJACENT WALL COLOR. FONT FOR SUITE IDENTIFICATION = MYRIAD PRO BOLD . ~--TENANT PANEL 3MM ACM WHITE ALUMINUM SIGN PANEL PAINTED MATTHEWS BRUSHED ALUMINUM W/ OPAQUE VINYL OVERLAY GRAPHICS. O '------------------------------J 0'4 STAND-OFFS 3/4" DIAMETER STAINLESS STEEL STANDOFFS (SATIN FINISH) TO SECURE TENANT PANEL IN PLACE, 1/2" AWAY FROM SUITE ID SIGN PANEL FACE. STANDOFFS SECURED TO WALL WITH STAINLESS STEEL HARDWARE AS REQUIRED FOR WALL TYPE. STANDOFFS MUST REMAIN IN PLACE ON THE I ~ WALL WHILE TENANT PANELS ARE BEING UPDATED OR REPLACED. TENANT SUITE ID SIGN SCALE: 1" = 1 '-0" .... ~--...... D.G1 Hera Hub 5205 A D.G2 Vacant 5205 C D.G3 MammaChia 5205 E D.IM VantageVue 5205 F --t-D.1115 Palomar Sign 5205 G ~ D.118 POI Coatings 5205 H D.07 Zoot!Squadra 5205 J -D.118 Total Gym 5225 C D.Cl8 All Flat 5225 F D.10 Kinnetic labs 5225 H D.11 MOVE 5245 H -- D.12 Vacant 5245 G D.13 Cruzan 5245 F --j- D.14 SOME 5245 E D.15 SOAR 5245 D D.18 Norden 5245 C D.17 Eric Hall & Assoc 5245 A D.18 Vacant 5235 t A D.19 Shootsta 5235 C --D.20 Jeffrey Franc 5235 D D.21 Classic Flooring 5235 E D.22 Suncoast 5235 F D.23 Serrano Systems 5235 G --- D.24 Solterra Lighting 5375 A D.25 carve 5375 B ~- D.28 City SC 5375 C D.27 Corinthian Trtle 5375 E D.28 @Work Personnel 5375 l F D.29 Hetherington Eng. 5365 A --+ D.30 New West Designs 5365 j..B -- D.31 Craig Coley 5365 C -------!. D.32 Mr Tint 5365 D - D.33 Vacant 5365 E ---D.34 Precision Medical 5365 F ---,.- D.38 Vacant 5365 G ~ D.38 Coast Sonic ~H --D.37 Motion Industries 365 J D.38 Teak&Deck 5355 111 D.311 Vacant 5355 110 --...,__ D.40 Perfonnance Medical 5355 1109 D.41 Greenleaf 5355 107 D.42 Engage Engineering 53551106 D.43 Vacant 15355; 105 D.44 Highlights SD 04 -- D.45 Wildbird 5355 103 D.48 Vacant 5355 100 D.47 ASI 5315 150 D.48 Golden Key ~130 D.48 Gir1 Scouts 5315 100 Commerce cruzan Project Location: 5205-5375 Avenida Encinitas Carlsbad, CA 92008 ProjectNo.: 200025-01 Salesman: Curt Bauer Duign■r: Angela M. Data: February 21, 2020 Scala: As Noted Revision: L L L L L L L L L L L L L L v~ ~/4 Integrated SIGNS DREAM IT• BUILD IT• SIGN IT 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 lsaslgn.com I Info@isaslgn.com ORIGINAL CONCEPT This design Is the exclusive property of Integrated Signs and cannot be reproduced In whole or part without their prior written consent. Shoat No.: 3 /4 0 MammaChia. SEED YOUR SOUL. 0 TENANT SUITE ID SIGN SCALE: 1" = 1 '-0" REPLACE EXISTING AT 5205 -SUITE E (SIGN AT SUITED -REMOVAL ONLY) ® QUANTITY: 1 I SIGN AREA: 7.1 SF SUITE ID PERMANENT BACKGROUND SIGN PANEL PAINTED TO MATCH MATTHEWS MP 41335SP ANODIC BLACK (SATIN FINISH). 1/8" THK. ALUMINUM PANEL SECURED 1/4" AWAY FROM WALL SURFACE WITH STAINLESS STEEL BACKPINS AND SILICONE ADHESIVE. USE 1/4" DIAM. ALUMINUM SPACERS, PAINT FINISHED TO MATCH ADJACENT WALL COLOR. FONT FOR SUITE IDENTIFICATION = MYRIAD PRO BOLD. TENANT PANEL 3MM ACM WHITE ALUMINUM SIGN PANEL PAINTED MATTHEWS BRUSHED ALUMINUM W/ VINYL OVERLAY GRAPHICS IN 3M BLACK OPAQUE. STAND-OFFS 3/4" DIAMETER STAINLESS STEEL STANDOFFS (SATIN FINISH) TO SECURE TENANT PANEL IN PLACE, 1/2" AWAY FROM SUITE ID SIGN PANEL FACE. STANDOFFS SECURED TO WALL WITH STAINLESS STEEL HARDWARE AS REQUIRED FOR WALL TYPE. STANDOFFS MUST REMAIN IN PLACE ON THE WALL WHILE TENANT PANELS ARE BEING UPDATED OR REPLACED. Commerce cruzan Project Loc1tion: 5205-5375 Avenida Encinitas Carlsbad, CA 92008 ProjectNo.: 200025-01 S1lesm1n: Designer: Date: Scale: 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Curt Bauer Angela M. February 21 , 2020 As Noted v~ ~/4 Integrated SIGNS DREAM IT • BUILD IT • SIGN IT 1160 Pioneer Way, Suite M El Cajon, California 92020-1944 T: 619.579.2229 I F: 619.579.7651 isasign.com I info @isasign.com ORIGINAL CONCEPT This design Is the exclusive property of Integrated Signs and cannot be reproduced In whole or part without their prior written consent. Sheet No.: 4 ,4